Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B11-0563 CALFIRE PRE-INSP (3)
�AL V188E5 Butte County Fire Department t>v Cot, Fire Prevention Bureau A 176 Nelson Avenue, Oroville CA 95965 az (530) 538-7888 Office, (530)538-2105 Fax SRA & LRA Building Permit OD)/ - UF-)(C' Address / Location: In ? yeni O.(A/LE ()wi1ii1i1h Under authority of Public Resources Code(PRC)Section 4290 and 4291,Butte County Improvement Standards(BCIS), California Building Code(CBC),and the California Fire Code(CFC),and Chapter 38A Butte County Code,the following items are required by CAL FIRE/Butte County Fire Department for all development located within the State and Local Responsibility Areas of Butte County and are required as part of this permit. These requirements are minimums and may be superseded by Butte County local regulations exceeding these standards. This reinspection is for: ❑ sidence Addition to existing structure Manufactured Home El Ancillary Building(detached garage,shop,shed,etc.) Public Resources Code 4290 ADMINISTRATION 1270 Maintenance of Defensible Space Measures '/ To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability,access,and utilization of the defensible space provided for these standards during a wildfire, provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit,parcel or map approval. RIVEWAY STANDARDS 1273.10 Driveways (a)All new driveway construction or an extension of an existing driveway shall comply with Public Resources Code 4290 roadway requirements. Driveways can only serve a single parcel. Length of Driveway A. (b)All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its \entire length. 1273.02 Driveway Surface • The surface shall provide unobstructed access to conventional drive vehicles,including sedans and fire engines. Surfaces should be established in conformance with local ordinances,and be capable of supporting a 40,000 pound load.4" of class 2 aggregate base shall be required for all driveways,turnouts and turnarounds. 1273.03 Driveway Grades • The grade for all driveways shall not exceed 15%without being paved. Grades over 15%shall have 4"of class 2 aggregate base and 2"of asphalt concrete.No driveways allowed in excess of 20%. 1273.04 Driveway Radius (a)No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall be added to curves of 50-100 feet radius;2 feet to those fi-om 100-200 feet. (b)The length of vertical curves in roadways,exclusive of gutters,ditches,and drainage structures designed to hold or divert water,shall be not less than 100 feet. 1 Legend:N/A=Not Applicable,X=Required Revised on 05/04/11 Trakit Copy 1273.05 Driveway Turnarounds (d)A turnaround shall be provided to all building sites on driveways over 300 feet in length,and shall be within 50 feet of the building. Turnarounds are required on driveways and dead-end roads as specified in this article.The minimum turning radius for La turnaround shall be 40 feet from the center line of the road. If a hammerhead-T is used,the top of the"T"shall be a i minimum of 60 feet in length. 1273.06 Driveway Turnouts (c)Driveways exceeding 150 feet in length,but less than 800 feet in length,shall provide a turnout near the midpoint of the driveway.Where the driveway exceeds 800 feet,turnouts shall be provided no more than 400 feet apart. Turnouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. 12 3.17 Driveway Structures `,k (a)All driveway,road, street,and private lane roadway structures(Bridges,culverts, and other appurtenant structures hich supplement the roadway bed or shoulders)shall be constructed to carry at least the maximum load and provide the minimum vertical clearance as required by Vehicle Code Sections 35550,35750 and 35250. All bridges shall be certified by a registered Civil Engineer. t\fr(b)Appropriate signing, including but not limited to weight or vertical clearance limitations,one-way road or single lane conditions, shall reflect the capability of each bridge. ac(c)A bridge with only one traffic lane may be authorized by the local jurisdiction;however,it shall provide for unobstructed visibility from one end to the other and turnouts at both ends. GATE TANDARDS 1273 (1a) Entrance (a)Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s)serving that gate. Minimum 14 foot opening. / All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall openallow a vehicle to stop without obstructing traffic on that road. (c)Where a one-way road with a single traffic lane provides access to a gated entrance;a 40 foot turning radius shall be used. SIGNING AND BUILDING NUMBERING 1274.00.Intent To facilitate locating an emergency and to avoid delays in response,all newly constructed or approved roads,street,and buildings shall be designated by names or numbers,posted on signs clearly visible and legible from the roadway. This section shall not restrict the size of letters of numbers appearing on street signs for other purposes. ADD1 ESSING 1274}./08.Addresses for Buildings �/ All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system.Accessory buildings will not be required to have a separate address;however,each dwelling unit within a building shall be separately identified. 127 .09.Size of Letters,Numbers and Symbols for Addresses Size of letters,numbers and symbols for addresses shall be a minimum 4 inch letter height,3/8 inch stroke, reflectorzed,contrasting with the background color of the sign. 127 .10.Installation,Location and Visibility of Addresses (a)All buildings shall have a permanently posted address,which shall be placed at each driveway entrance and visible from both directions of travel along the road.In all cases,the address shall be posted at the beginning of construction and shall be maintained thereafter,and the address shall be visible and legible from the road on which the address is located. 2 Legend:N/A=Not Applicable,X=Required Revised on 05/04/11 Trakit Copy • ADD SING(cont) 1 (b) ddress signs along one-way roads shall be visible from both the intended direction of travel and the opposite Won. (c)Where multiple addresses are required at a single driveway,they shall be mounted on a single post. Ad) ere a roadway provides access solely to a single commercial or industrial business,the address sign shall be placed at a nearest road intersection providing access to that site. FUEL M DIFICATION STANDARDS 1276.00 ent To reduce he intensity of a wildfire by reducing the volume and density of flammable vegetation,the strategic location of fuel modification and greenbelts shall provide: (1)Increas safety for emergency fire equipment and evacuating civilians; (2)A poin of attack or defense from a wildfire. 1276.01 S tback for Structure Defensible Space SRA only RA- [ ] 44-t- All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from al property lines and/or the center of the road. 1276. posal of Flammable Vegetation and Fuels Dis••sal,including chipping,burning or removal to a landfill site approved by the local jurisdiction,of flammable vegetation . 1 d fuels caused by site development and construction,road and driveway construction,and fuel modification shall be co u'pleted prior to completion of road construction or final inspection of a building permit. DEFENS i:LE SPACE GUIDELINES Pube ources Code 4291 A parson that owns,leases,controls,operates,or maintains a building or structure in,upon,or adjoining any mountaino s area,forest-covered lands,brush-covered lands,grass-covered lands,or any land that is covered with flammable material,s'all at all times do all of the following: (b) aintain around and adjacent to the building or structure additional fire protection or firebreak made by removing al brush, 'i ammable vegetation,or combustible growth that is located within 100 feet from the building or structure or to the property 1'I e or at a greater distance if required by state law,or local ordinance,rule,or regulation.Grass and other vegetation located more than 30 feet from the building or structure and less than 18 inches in height above the ground may be maintain• where necessary to stabilize the soil and prevent erosion.This subdivision does not apply to single specimens of trees or o 1 er vegetation that is well-pruned and maintained so as to effectively manage fuels and not form a means of rapidly transmi ' .fire from other nearby vegetation to a dwelling or structure. /( movc) e e that portion of any tree that extends within 10 feet of the outlet of a chimney or stovepipe. ,-(d) aintain any tree adjacent to or overhanging a building free of dead or dying wood. (e)Maintain the roof of a structure free of leaves,needles,or other dead vegetative growth. Prior to constructing a new building or structure or rebuilding a building or structure damaged by a fire in such an area,the construction or rebuilding of which requires a building permit,the owner shall obtain a certification from the local building o cial that the dwelling or structure,as proposed to be built,complies with all applicable state and local building standards,including those described in subdivision(b)of Section 51189 of the Government Code,and shall provide a copy of the ce fication,upon request,to the insurer providing course of construction insurance coverage for the building or structure. pon completion of the construction or rebuilding,the owner shall obtain from the local building official,a copy of the final '•spection report that demonstrates that the dwelling or structure was constructed in compliance with all applicable state and l•cal building standards,including those described in subdivision(b)of Section 51189 of the Government Code, and shall •rovide a copy of the report,upon request,to the property insurance carrier that insures the dwelling or structure. 3 Legend:N/A=Not Applicable,X=Required Revised on 05/04/11 Trakit Copy Public R urces Code 4621 thru 4628 and California Forest Practice Rules Article 7 SRA only brio to any lot clearing activity or cutting of trees,contact the Butte area Forester at(530)872-6353 to determine the need for a ess then 3 acre conversion exemption permit or a timber harvest plan.If required,a copy of the Timber Harvest Plan or 1 than 3 acre conversion exemption permit will need to be reviewed at the final inspection. E:1 -Permi required rd Permi not required 2010 Cali rnia Fire Code LPG Tanks 38 3,LPG Tank Clearance of Combustibles 4 ee ,grass,brush,trash and other combustible materials shall be kept a minimum of 10 feet from LP-gas tanks or containers. ! 380 .4 Pr tecting LPG containers from vehicles \ A i Where exposed to vehicular damage due to proximity to alleys,driveways or parking areas,LP-gas containers, egulators nd piping shall be protected in accordance with Section 312. Fire epa went Fees Fire department fees are collected by the Butte County Development Services Department at the time of application for your buil g permit.You are assessed two fees(pre-inspection and final inspection).Additional fees will be assessed when the fire d artment inspector is required to perform additional re-inspections of your property,those additional ees must be paid to Development Services,7 County Center Drive in Oroville. Californi Building Code Chapter 7A, Materials and Construction Methods for Exterior Wildfire Exposure Check wit Butte County Department of Development Services—Building Division for specific questions regarding Chapter 7A of the California Building Code and its application to your project. Also,check the websites below for useful info ii ation including the full text of Chapter 7A CBC. To find acceptable Chapter 7A products:Click on NEW PRODUCTS HANDBOOK http://www.fire.ca.gov/fire_prevention/fireprevention wildland.php Al of the Fire Safe Requirements are posted on the Butte County Fire Department website at http://www.buttefire.org Check the status of your permit online at http://dspermits.buttecounty.net/etrakit/Permit_Search.asp Need afire department inspection? Call our inspection line. (530) 538-6226 11_ 1",4110011tg, C Inspector Date 1 I erty Owner f a'; actors Signature "\ — (� R- �—)c A . t >A ..tGalb Assessors Parcel Number •wners ame 4 Legend:N/A=Not Applicable,X=Required Revised on 05/04/21 Trakit Copy Traket Notes zA6' le to final project at time of pre-inspection. Add this note in Traket. Remove final inspection fee. Needs another final re-inspection. Needs another final re-inspection fee. Pre-inspection form needs last page to be completed; APN # Pre-inspection form needs last page to be completed; owner info Pre-inspection form needs last page to be completed. ' California Department of Forestry and Fire Protection ice` Butte County Fire Department Fire Prevention Bureau ' gA�':...aik: 176 Nelson Avenue, Oroville, CA 95965 •. iN (530) 538-7888 Office, (530) 538-2105 Fax Final Inspection Sheet Property Owners ame: V (t,t 4i// � l4 Property Location: 17-a. ,4P.Q At p �"t-� City: r ....6 Inspector:`,', to(..2y• Ifispection Date: 9-/ 3 // Pennit#Sii--0 g-6 APN#03 — AR -0-4---S- Correct ©' 5Correct Notes }::.::,-.;::;-}>::.::.}iii: l t:i:.:.:}t}:}:x::;`Ri::.^>:;;.;.:'':{•";:5::M:ii:::.}:.}:.}:: >:::>{:::.g i1:<.iiiE::;>::<:;>:::::>::::i<::;::::<::<}:::ir<::: 0 1273.02 0 Roadway 0 Driveway Surfaces 1273.03 0 Roadway 0 Driveway Grades 1273.04❑Roadway 0 Driveway Radius 1273.05 0 Roadway 0 Driveway Turnarounds _ 1273.06 0 Roadway 0 Driveway Turnouts 1273.07 0 Roadway 0 Driveway Structures 1273.08 One-Way Roads _ 1273.09 Dead-End Roads 1273.11 ❑Roadway 0 Driveway Gate Entrance ...... ......:. .......... r. .:. {;.:::::.ter.:,:::.:.:::.:. 12 4.01.Size of Letters,Numbers and S mbols for Street and Roads Si:ns _ 12 r4.03.Height of Street and Road Signs 12174.05.Intersecting Roads,Streets and Private Lanes Adk 1274.06.Signs Identifying Traffic Access limitations 1274.07.Installation of Road,Street and Private Lane Signs digM :::::................ / y .1274.08.Addresses for Buildings / 1474.09.Size of Letters,Numbers and Symbols for Addresses r ��'n 1274.10.Installation,Location and Visibility of Addresses ���✓!� Yt— riL 'r V. .. . ............... ............. 7..............................:..................:}:.. :..::::::::::.:::.�:::::.:::::::.:.:::::::::::,.::::::::•::::....n:..n....}'.o.}o. :.... J!}.b::;.}}i:iiii:`•}}:.{{{{}:.}}::::::{n.<:n::o{{c«.}ra:{.;;:A p,yY �y�tyy�� f;��5'�+.'�''.'��'.'��''��'.'�.�''�.�''��'.'��'.�'�'.'��'.��i�i:.:ii:::::: :::iii::::: ::::'::::::':�'::......2'v'::. :::::::.:::::::: ..........:.......:..n.:rn........ :..... ....v.:.....:::..n.v::::,,..-v'•}Y:..::{:v;v•::::::: ..:............ ...................... .....:v...............:.F.:.v::•.:;.•::;;•%{t:•}}:.: ?.�.i ...:....... :�t�p� :�`" :.}n%Arc::::ae�:?:x,'i2::::;_:;;:;:::: :::i`.:;::::a:..:.ii .,... ...... .. .. s•.... 4'3.... ...r............. ...,,Y ruu .0...-:,,,,+h----....... -.... .. .. .......--...........r.n.-.n..............,..j.?%f..n..;.::}::::n:v::::::::.:v:.:..:..:..;, ..:::....:::.::{:w A, '� 1276.01 Setback for Structure Defensible Space , Same Practical Effect Requirements for buildings less then 30 feet from property line 1276.02 Disposal of Flammable Vegetation and Fuels ..r .:::<::,: ami i i >:',.`x `t ttl l'.`�}.:.":t mpogge'C v' s } :»:>::;:> '>::':`��><>>>iii f>f'i>€i g.wommim ':'i .:........./1/1"-- �� �..�......, ,..>�w...r ��+. .,.......u..:�. .,. w .............�............�..::....::::.....:..:...:.v:::.,:..::.::,:•:::..::::.::•:::..:•:�:::::ter 'I If required,request to see a copy of the conversion permit or Timber Harvest Plan • :::.v�r. �+�y ^ ::7ry�n ..F. ..{4:.x •.r}.:{ }JN,w%:$k?L>,v..�;fn n:$.v wA�J .. . ..:..ti' ''"�I::L!:V "..:kfM: .'.:IGf1�F.3:7:�:'��'.lv'i.S)lk:k� :1�4:i:F3:(::7C�::i'i::i::i:� .,:�Ir`r':i`•. Jii`� ''J'.::}:.A w:ti Ki � ::`.{ •;-it.. ................::::�:::::. : � �IU� ........: . .. `. .. h.. ... ..... {::.:,,.........................;.i:•::::...Jiii{,{:'y:v:•':titi}. rr;: .......................................................................................................::::::.........................................:.:::..... dc;.r '�i:' �*:}%:•:}:;.:.;;;;;:.;;;;;t;;;;:.}:.}:{%: :.;}•... I .:.... lam}..J,fs^k. �, :•.:ct,: ... ...:...........•.:......:..:..::. :...:...:}:.:...::::.:::::nnv.vv.. 'r Y:.ir.X-K:.:: ,:.0:.vn•.•.vv:.:.::.\:v.:. :>� :::.:}:.::.::.::.:::{{{•;::w;:;•::.:•;:: 1.'..::...:,.. ;: .:':.... :...�. il�l�:�•�'�i �.�.�r:��.R:.�i�i,'i ��i... :W' .�.�iT'a:�w�l �.ti.i '.i�s.:::: ..::.:.:.:.: goAo 704A.1.2 Roof coverings 704A.1.3 Roof valleys 704A.1.5 Roof gutters 704A2.2 Eave or cornice vents 704A.2.3 Eave protection 7C4A.3.1.1 Exterior wall coverings 7C4A.3.2 Exterior wall openings 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls 714A.3.2.3 Exterior door assemblies 704A.4.1.1 Decking surfaces 7(4A.4.2.1 Underside of appendages and floor projections. 7(4A.4.2.2 Unenclosed under floor protection C tapter 15 Roofing and Roof Structures 1503.1, 1503.2, 1503.3 Roof Coverings within State Res.onsibilit Area :•?':::.:{t;..:�..:..:....:.::••;{.,.. rx::. p'Yif:/:{.T:iR;4.4X ::�'r.��K%::i�iiiii$iii::isi{ ii£?i:iii?: : ::':: . :RI.i RM }:::nv:::::::::n..::.r't iii ii;{,.':"Y::::;:.. .::..,.:K.:.{;..::{;;{,::}:}:::.:..:.' ... .................. •i:Ski : :`%: : :i:i:iii:i:i::;:f:iii:i: ;i :::ii•r%;ii: Yiii::;i:fiii Gi;{f 'ri' ::Y{x:.:....... 3807.3,LPG Tank Clearance of Combustibles �.t.(..Ley F 3807.4 Protecting LPG containers from vehicles RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR int 3rd 1 2"d Inspection passed on:?_/ l/ it-, ,t,LA,..,, ,'' The above 0 residential t...„,„,64, ,,_,.,- , o ancillary structure has been built to meet all applicable state and local fire safe standards including those • stand ds described in Government Code Section 51189(b). Inspector Signature 4Djo±u STATE OF CALIFORNIA DEPARTMENT OF FORESTRY AND FIRE PROTECTION cat NOTICE OF DEFENSIBLE SPACE INSPECTION rpF LE-100 (REV.April 2009) NOTICE OF DEFENSIBLE SPACE INSPECTION THIS IS A LEGAL NOTICE OF FIRE HAZARD VIOLATIONS(IF NOTED IN BLOCK 32) SHADED BOXES MANDATORY-ALL OTHERS OPTIONAL ,1.IINSPECTOR'S ULL NAME(FIRST,M.I.,LAST) 2.INSPECTOR'S TITLE 3.BADGE NUMBER 4.INSPECTOR'S AGENCY 5.INSPECTION DATE NCP / ex �4:.-+ ve t S .5-c3 i�Z `p °%S'� 6. / 7.UNIT ID 8. BATTALION NUMBER 9.STATION NUMBER PROTECTION RESPONSIBILITY SRA LRA FRA 1 7t) ( BIA 0 0 ❑ 10.AP BOOK 11.AP PAGE 12.AP PARCEL# CAL FIRE 0 El Mff ❑ 6 3 0 A 0 0 Contract County 0 0 0 13.LATITUDE (Datum=WGS84) 14.LONGITUDE (Datum=WGS84) USFS 0 ❑ 0 (Decimal Degrees;ex:38.5761) (Decimal Degrees;ex:121.4969) Other 0 ❑ ❑ 15. If mailing address for notices is other than inspection to tion,check here: ❑ and write complete address in comments section. 16.NAME(LAST,FIRST) G!� wvj tt W 17.ADDRESSi U w18.CITY' , 19.STATE 20.ZIP Cl) r i CA 21. PHONE NUMBER #1 22.PHONE UMBER #2 23. E-MAIL ADDRESS 24.COMMENTS:, , 1105-63 IF YOU HAVE QUESTIONS CONCERNING THIS INSPECTION NOTICE,CALL THIS PHONE NUMBER: 25. 26. INS -TION# 27. CITATION# 28.FOLLOW-UP INSPECTION DATE: VIOLATION REINSP N? - 0 0 0 0 0 . El � YES. NO 1 2 3 1 2 3 (MM/DD/YYYY) rvi- 31. 29. o violations observed. 30.0 Alternative practices approved having same practical effect. ACTIONS TAKEN applicable) See comments section above(14 CCR 1299(c) (check ifbsery 0 Left information material (check if applicable) Discussed clearance with resident 32. eft copy of this inspection notice ❑ Violations were observed. Additional clearance is needed for the following areas: ❑ Citation issued ❑ Recommend citation to prevention ❑ 30 foot zone,PRC 4291(a)(1);14CCR 1299(a)(1)❑Grass ❑ Brush ❑ Trees ❑ Shrubs 33. GENERAL BUILDING CONSTRUCTION TYPE ❑ Reduced Fuel Zone(30'-100')PRC 4291(a)(1);PRC 14CCR1299(a)(2) ❑Grass ❑ Brush ❑Trees Shrubs 1 ❑ Wood Siding ❑ Remove specific hazardous fuel identified by inspector-14CCR 1299(b) 0 Wood Roof ❑ Dead and dying woody surface fuels-14CCR1299(d) on-combustible siding E[].-AanUfactured(Mobile)Home Remove portion of a tree that extends within 10'of the outlet of a chimney or stovepipe PRC 4291(a)(4) ❑ Metal 1:1 Maintain any plant adjacent to or overhanging a building tree of dead or dying wood-PRC 4291(a)(5) ❑ Concrete/Block ❑ Other ❑ Maintain the roof of a structure free of leaves,needles,other vegetative matter-PRC 4291(a)(6) Deck Present 0 YES ' ❑ Provide and maintain at all times a screen over the outlet of every chimney or stovepipe that is attached to a For ways to preventemberintrusion into your fireplace,stove,or other device that burns any solid or liquid fuel. The screen shall be constructed of building during a wildfire,see nonflammable material with openings of not more than one-half inch in size. CFC 603.8;CBC 2802.1 http://www.fire.ca.gov/fire_prevention/downloads/ 2007 CBC Ch7A.pdf 34. FOR ADDITIONAL INFORMATION ON HOW TO COMPLY WITH DEFENSIBLE SPACE CLEARANCE REQUIREMENTS,PLEASE VISIT: WVVVV.FIRE.CA.GOV I General Guidelines for Creating Defensible Space are found at http://www.fire.ca.gov/CDFBOFDB/pdfs/Copvof4291finalquidelines9 29 06.pdf