Underground LPG Tank Inspection Form
,„!,,...:
c ,„
� ,� California Department of Forestry and Fire Protection . i.G
4 r' Butte County Fire Department ‘,.;f--.-
176 Nelson Avenue,Oroville, CA 95965 • (530)538-7888 ,r`'
Property OwnerN3. ici5 c roperty Location: lib.61-1 g,A & 1 City: 0'4 i r_iN,
Inspector: Inspection Date: t-oia l Permit#: tjy-® I 1-1-a - APN: (i6.7--g,::2-6 643
A5ME Tank Infor tion:NFPA 58:2001 edition
.seApproved underground tank installed with no vehicle traffic shall be at least 6 inches below grade.NFPA 58: 3.2.9.1(a).
❑Approved interchangeable aboveground/underground installation,maximum depth. 12 inches below grade NFPA 58:3.2.9.1(d)
❑Approved non-interchangeable underground installation shall have a minimum depth of 18 inches or provide adequate vehicle
protection for all appurtenances. NFPA 58:3.2.9.1(b)
Location of Tank: NFPA 58: 2001 edition
❑ YES ❑NO Tanks of 125-gallon water capacity and under at least 10 feet from all buildings and property lines.NFPA 58:
S 3.2.2.2
,,BYES ❑NO Capacity from 125 -2000 gallons is at least 10 feet away from all buildings and property lines?
NFPA Table 58:3.2.2.2
Capacity from 2001 gallons and larger shall be 50 ft from buildings/property lines.
NFPA Table 58:3.2.2.2
❑YES ❑NO All sources of ignition at least 10 feet away from tank appurtenances.NFPA 58: appendix figure I: 1(c)
Tank Installation:NFPA 58:2001 edition
-.AYES ❑NO Underground tank installed upon a level surface.NFPA 58: 3.2.9.1. (i).
,YES ❑NO Adequate vehicle protection of tank appurtenances.NFPA 58 :3.2.9.1(b),(c)&NFPA 58:A-5.4.2.2.
;14ES ❑NO Minimum 14 AWG corrosion resistant tracer wire(entrenched)being visible at riser or building.
NFPA 58: 3.2.16.9.
❑YES 4rNO Tanks shall be coated to protect against corrosion. NFPA 58 3.2.9.2(h),NFPA 58: 3.2.4,NFPA 58:A-
3.2.9.3(c)(d).
Pr- )e sure Relief Devices: NFPA 58: 2001 edition
DIYES ❑NO Adequate protection provided to prevent water or debris from entering the relief valve or discharge
piping. NFPA 58:3.2.11.4.
Uplerground tanks with less than 2000 gal. Capacity:
,tr,YES ❑NO If relief device discharges into manhole or protective shroud, the manhole shall be equipped with
ventilated louvers or passive system to provide ventilation. NFPA 58: 3.2.11.6(See exceptions for
� dispensing stations)
"YES 0 NO If discharge piping has been installed has the relief valve capacity been verified as
adequately meeting its discharge capacity.NFPA 58:3.2.11.8,2.3.2.4. (a).
Underground tanks with more than 2000 gal.Capacity:
❑YES ❑NO Discharge from pressure relief is piped vertically and directly upward to a point at least 7 feet above the ground
level. NFPA 58:3.2.11.7 (See exceptions for dispensing stations)
Corrosion(Cathodic)Protection: NFPA 58: 3-2.24.58:A 3.2.9.3(d),58: A 3.2.2.4
Specify Type of Backfill Material: Backfill Material: ❑ Dry ❑Damp ❑Wet
❑YES Zr1•1O Additional coating materials applied to surface areas disturbed during installation or shipment of tank
❑YES FrNO After installation of anode and prior to backfilling the anode bag(s)was pre-soaked with water.
❑YES AO Installation site, anode bag, and backfill naturally wet due to weather or other conditions:
/YES ❑NO An, hod bag lead wire accessible inside dome for testing.
r o 4—
Comments: ,412-f Q.t4 6'-it---Ta/144----
/,
OK to Enter in Trakit Date: I 0 —o?/ — 0 Initials: ��. -
Underground LPG Tank Inspection Form—Master 6/2/07
CAL
Underground LPG Tank Inspection Form
'CAL
F/RE
California Department of Forestry and Fire Protection .
Butte County Fire Department
176 Nelson Avenue Oroville, CA 95965 ■ (530)538-7888
�
Property Owner: Q _� a`��' — Propeoc_aBon: e4 City: . )
Inspector: `L J\ Inspection Date: Sal i, cLXt5_- Permit#:,664¢—/Vq' APN: - 7�,J
c�O-6 4.
AME Tank Information: NFPA 58: 2001 edition
Approved underground tank installed with no vehicle traffic shall be at least 6 inches below grade.NFPA 58: 3.2.9.1(a).
❑Approved interchangeable aboveground/underground installation,maximum depth. 12 inches below grade NFPA 58:3.2.9.1(d)
❑Approved non-interchangeable underground installation shall have a minimum depth of 18 inches or provide adequate vehicle
protection for all appurtenances.NFPA 58:3.2.9.1(b)
Location of Tank: NFPA 58: 2001 edition
❑YES ❑NO Tanks of 125-gallon water capacity and under at least 10 feet from all buildings and property lines.NFPA 58:
3.2.2.2
YES Q NO Capacity from 125 -2000 gallons is at least 10 feet away from all buildings and property lines? _51—,0 0
NFPA Table 58:3.2.2.2
Capacity from 2001 gallons and larger shall be 50 ft from buildings/property lines.
NFPA Table 58:3.2.2.2
❑YES ❑NO All sources of ignition at least 10 feet away from tank appurtenances.NFPA 58: appendix figure I: 1(c)
Tagk Installation:NFPA 58: 2001 edition
ES ❑NO Underground tank installed upon a level surface.NFPA 58: 3.2.9.1.eX,ES ❑NO Adequate vehicle protection of tank appurtenances.NFPA 58 :3.2.9.1(b), (c) &NFPA 58:A-5.4.2.2.
DYES ❑NO Minimum 14 AWG corrosion resistant tracer wire(entrenched)being visible at riser or building.
NFPA 58: 3.2.16.9.
❑YES 77;10 Tanks shall be coated to protect against corrosion.sizkmA ' NFPA 58 3.2.9.2(h),NFPA 58: 3.2.4,NFPA 58:A-
3.2.9.3(c)(d). 2
Pre re Relief Devices:NFPA 58: 2001 e tion 64_71
If YES ❑NO Adequate protection provided to prevent water or debris from entering the relief valve or discharge
piping. NFPA 58:3.2.11.4.
Ug 1'erground tanks with less than 2000 gal. Capacity:
YES ❑NO If relief device discharges into manhole or protective shroud,the manhole shall be equipped with
ventilated louvers or passive system to provide ventilation. NFPA 58: 3.2.11.6 (See exceptions for
dispensing stations)
1 YES ❑NO If discharge piping has been installed has the relief valve capacity been verified as
adequately meeting its discharge capacity.NFPA 58:3.2.11.8,2.3.2.4.(a).
Underground tanks with more than 2000 gal. Capacity:
LI YES ❑NO Discharge from pressure relief is piped vertically and directly upward to a point at least 7 feet above the ground
level. NFPA 58:3.2.11.7 (See exceptions for dispensing stations)
Corrosion(Cathodic)Protection: NFPA 58: 3-2.24. 58:A 3.2.9.3(d), 58:A 3.2.2.4
Specify Type of Backfill Material:')Q,1kAL Backfill Material: ry ❑Damp ❑Wet
❑YES O Additional coating materials applied to surface areas disturbed during installation or shipment of tank
❑YES ❑NO After installation of anode and prior to backfilling the anode bag(s)was pre-soaked with water.
❑YES IX(O Installation site, anode bag,and backfill naturally wet due to weather or other conditions:
ZI4 ❑NO Anode bag lead wire accessible inside dome for testing.
is
I
Comments: — •s- ✓i1..� -!� i ,�2 I _ i ir
zr, 1
�0 ���,.•=!��..i .�IsLLa III%r�L�
OK to Enter in Trakit 0 Date: itials: ���