Loading...
HomeMy WebLinkAboutB06-2901f 0& z, California Department of Forestry and Fire Protection CAL E Butte County Fire Department SINCE 1885 Fire Prevention Bureau 1< co,„ 176 Nelson Avenue, Oroville, CA 95965 J 77: i (530) 4 +; ,� 538-7888 Office, (530) 538-2105 Fax S ITE Final Inspection Sheet Property Owners Name:I` 1' 6 9 t?A j J'p Property Location:J 0 Li 41 1/0` - milt cih,..4--O ce S f �'t- Inspector:yvp 4/+T Inspection/Date: / 1---&-%Permit#,9( —Z 9-N/ APN# V� 3 " Lfe) _0 h C Correct Notes y N ROADWAY/DRIVEWAY STANDARDS 1273.02 0 Roadway 91.Driveway Surfaces JLJ 4 1273.03 0 Roadway 0 Driveway Grades 1273.04 0 Roadway 0 Driveway Radius 1273.05 0 Roadway 0 Driveway Turnarounds 1273.06 0 Roadway 0 Driveway Turnouts 1273.07 0 Roadway 0 Driveway Structures 1273.08 One-Way Roads 1273.09 Dead-End Roads 1273.11 0 Roadway 0 Driveway Gate Entrance STREET&ROAD SIGNS 1274.01.Size of Letters,Numbers and Symbols for Street and Roads Signs 1274.03.Height of Street and Road Signs 1274.05.Intersecting Roads,Streets and Private Lanes i 1274.06.Signs Identifying Traffic Access limitations 'VP 1274.07.Installation of Road,Street and Private Lane Signs ADDRESSING 1274.08.Addresses for Buildings 1274.09.Size of Letters,Numbers and Symbols for Addresses - 1274.10.Installation,Location and Visibility of Addresses OTHER 1276.01 Setback for Structure Defensible Space C Same Practical Effect Requirements for buildings less then 30 feet from property line n 1276.02 Disposal of Flammable Vegetation and Fuels PUBLIC RESOURCES CODE 4621 THRU 4628 AND CALIFORNIA FOREST PRACTICE RULES /�� If required,request to see a copy of the conversion permit or Timber Harvest Plan •;CALIFORNIA BUILDING CODE CHAPTER.7A, MATERIALS&CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE: 704A.1.2 Roof coverings 704A.1.3 Roof valleys 704A.1.5 Roof gutters 704A2.2 Eave or cornice vents ,, 704A.2.3 Eave protection 704A.3.1.1 Exterior wall coverings 704A.3.2 Exterior wall openings J1/ 704A.3.2.1 Exterior wall vents 704A.3.2.2 Exterior glazing and window walls 704A.3.2.3 Exterior door assemblies . 704A.4.1.1 Decking surfaces 704A.4.2.1 Underside of appendages and floor projections. f'L 704A.4.2.2 Unenclosed under floor protection Chapter 15 Roofing and Roof Structures 1503.1, 1503.2,1503.3 Roof Coverings within State Responsibility Area y CALIFORNIA FIRE CODE .> /\ /, 3807.3,LPG Tank Clearance of Combustibles 3807.4 Protecting LPG containers from vehicles RE-INSPECTION DATES INSPECTOR RE-INSPECTION DATES INSPECTOR 1st 3rd 2nd Inspection passed on: / —22,-0X RL9 i i• 1 The above esidential 0 ancillary structure has been built to meet all applicable state and local fire safe standards including those standards escribed in Government Code Section 51189(b). I c or Signature