HomeMy WebLinkAbout028-050-007028-054=007 - 00-1811 CONWAY, MARK 1313 MIDDLE HONCUT, HONCUT CONTR: OWNER DEMO SINGLE FAMILY COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 P RMTNO. (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER 1 I TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAIUNG ADDRW /` `T 7 .... CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filen Fee $ 20.00 Permit Fee $ 15.W ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS 1313 t41DDU HONCUT �R1 '; " 'fiONCUT - Energy Plan Checking Fee $ $ PERMIT FEE $ 00 LOT No. SUBDNSaNS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF C. Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: DEMO TIOUSE Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service 200, OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: %' 111 as owner of the property, or my employeeswith wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwomply with those provisions. -1 y� r X f f b,7 �U F 1 `-4- Date � ' ! � � 1 � � _ Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for exca Qns over 5'0" deep and demolition or construction of structures over 3 stories in height Main Service TO t 46. 00 WEU200A NEW CONST. DWEWNG OCCUP. SO U so OR ADDNS. a ACC. BLOS. 3.50FT. NEW NON-H61D. MULTI.OUTLET @7,50 aPSINOWERLEUAPPARATUS GOTLET CIR. ounFTORFonvREs Ex. Occu Bnl0. ° 1: 0 Ex. Occup. ouTLEeDrsA(RREES,6.) Ek 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE `$ MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 35.00 HAZ. D. FEES IMP I FLOOD COF PARCEL PD I HD I ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date /- PERMIT EXPIRES ON (Date) Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (530) 538-7541 PER T (Rev.12/96)- APPLICATION AND PERMIT Wo ASSESSORPARCELNUMB - oo -7 ,� ZONING BUILDING PERMIT OWNER lTlr�'� W � � � .� l TELEPHONE�x" SO. FT. OCC. BUILDING VALUATION OWNER ,,,0 ,ADO i9 ^ ,-; 3 PALERMO ��//VV!! l/LL�t�J((© d/1 CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Flin Fee $ 20.00 Permit Fee $ 15.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS 1313 MIDDLE HONCUT RD., HONCUT Energy Plan Checking Fee $ $ PERMIT FEE Sic; nn LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF EX Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: DEMO HOUSE Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.00 Main Service 2o0A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.S License Class LIC. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, ill do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. s0 OR ADDNS. a ACC. BLDS. 3.5QFT. NOµREOSIUT' MULTI.OUTLET @7,50 PSINGLE OUTLET CIR.OWER APPARATUS 20 @ 1'00 Ex. Occup OUTLET OR FaTUREs SAL p .50 Ex. Occup. oFlxi,TE�oTSA a� ORS 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith omply with those provisions. � X (�! Date / "��Ci-y _ Signature of Applicant - ❑ Owne ❑ Contractor ❑ Agent An OSHA permit is required for exc s over 5'0" deep and demolition or construction of structures over 3 stories in heig MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 35.00 HAZ. D. FEES IMP FLOOD CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. /) By i Date 4 PERMIT EXPIRES ON Date Receipt No. i WHITE-D.D.S.-B.O. CANARY -A ESSOR PINK -INSPECTOR GOLDENROD -APPLICANT +COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 P R NO. (Rev.IZV6) - APPLICATION AND PERMIT Ac A&$ft"A0,*=ftWjW0 v 06zQ - 0 D°110 11 BUILDING PERMIT °MfNa" 1w/("V_ SO. FT. OCC. SIALDIN VALUATION DMMii011 rAa.io AooRsa coMTRAcm" NAME OOMTRACTORI MOA M0 ADORER CONtTRUCTIOM Unoe1 u[Noers MA"JA ADORE" ARMTECT oil EMOM M ARCWZCT 011 e10MEM S UNUM ADOAM OUIDNO ADORM J may/ In IDT NO. I sLeavao"N"a eqT, # j USEOFSTRUCTURE SF X Duplex O Moblehome O Other svEcsv TYPE OF WORK New O Addition O-'}�RemodddeellnO UhNers O/�In/staalllation O Other O Describe Work: a/fir=i'//� —' �(/ RECEIPT # ;9U m% PERMIT FEE $ cJ SRA $ SHR $ CSA 87 $ CUA $. TUA $ REC $ OTHER: Plan Checking Fee s Energy Plan Checking Fee TOTAL $49 I'n;j Fireplace EX. Occup. OUTLM P'LMESID.)EA 5.00 Total Valuation is 23.00 Mobile Home Facilities 20.00 Flirt Fee $ 20.00 Permit Fee $ �Q Plan Checking Fee s Energy Plan Checking Fee s s PERMIT FEE ! PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 Solar or hent pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 Gas piping system t - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W (0120.00 PERMIT FEE s ELECTRICAL PERMIT Filing Fee 20.00 Main Service 200A OR "ISS 23.00 Main Service 200A TO 1000A 48.00 NEW CONST. r OWEL N0 OCCUP. \ .. —so. EX. OCCU . OUTLET OR nCrURES EX. Occup. OUTLM P'LMESID.)EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE s III MECHANICAL PERMIT Fling Fee 20.00 1 Hood I 1 8.501 1 PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection fee s D" CONST' TTS TOTAL FEE $j e NAZ 0. MaNIP R,000ROD COF PARCEL PD This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work Indicated above for which fees have been paid. By PERMIT EXPIRES ON Date ----— Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and . return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit wM be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed pro erty improvement : YES[)4 NO[ . ]. 2. I HAVE jq HAVE NOT[ , ] signed an application' for a binding permit for the proposed work.. ._: .. - 3. I have contracted with the following person (firm) to provide the proposed construction: NAME: ADDRESS: :. CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired_ the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. .I will provide some of the work but I have contracted (hired) the following-femi ns to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: e� ,PROPERTY OWNER: SOCL-kL SECURITY NUMBER: - DATE:" NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. May 1995 2.26 Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of . property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party 6f record on such a permit Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself+ you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with. the exception of various trades that you plan 'to subcontract, you should be aware of the following information for your benefit and protection: -: 0 If you employ or otherwise engage any'persons other than your immediate family, and the work (including materials and other costs) is $300, or more for the entire project, and such persons are not :licensed as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and. yoik are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. . 0 There may be financial risks for you if you do not carry out these obligations,'and these risks are. especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific inbrmatioi about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "ownerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is retained Sincerely, Michael C„ Vieira, C.B.O. Manager, Building Inspection NOTE: This 0,xne: •Builder Information is required by Section 19830 of the California Health and Safety Code. 2.27 Mav 1995 t NOTES RESIDENTIAL , f- 028-050-007 00-1965 PERMIT NO. _ CONWAY, MARK & SECUNDA 1313 MIDDLE HONCVT RD.,HONCVT CONTR: EXECUTIVE HOMES NEW MH ON PERM FND (REPLACE) SPECIAL CONDITIONS CHECKED BY SRA I+ FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY f USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER OFFICE COPY Address I � GAS Meter By Date ELECTRI ' Meter By D JOB FINALED Signature ,/ = OK 0 = Not OK = Not Applicable MOBILE HOMES f = Not Ready Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ PLPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOWE INSTALLATION (Plans) OK except #'s -11 - v "Fgptings; Size -Spacing -Marriage Line i s; MH Test -Demand -Valve -Connector Vppctricity; MH Test -Crossovers -Breakers -Clearances Zoning Requirements -Setbacks -Easements ain; MH Test -Fall -Flex Connector 2. Wate , MH Test -Regulator -Connector 7. W er and Sewer Connected -C/O to Grade -HD Approval V . Gas and Electricity Tagged \� 9. Tie Downs -Type -Installation Cert. 40. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundatio Only; License Decal l �7 rElir �r G✓A� L F6�y' Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 i MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J = OK 0 = Not OK - = Not Applicable =Not Ready RESIDENTIAL? (; Date Underfloor (Plans) OK except #'s Hangers -Post Caps -Anchors -Connectors 1. Zoning -Setbacks -Easements -Flood -Slope Cling. Joist-Rttr. Ties- Purlin-Rolf Bac.-Truss-Shting.-Rfng. 2. Fig., Main; Soils-Elec. Grnd.-/ /" Fig. Depth Fireplace Ties or Type A Flue -Fireplace Throat Clearance 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 5. Stemwalls, Main; Steel-Blockouts-Wrapped Garage Fire Protection Framing 6. Stemwalls, Garage; Steel-Blockouts-Wrapped Property Line Firewall & Openings 6a. Hold Downs and Special Anchors Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 7. Slab, Steel -Wrapped Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 8. Piers -Fireplace Ftg.-Steel Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Siding -Nailing Veneer 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 11. Water Pipe; Test -Anchors -Regulator -Service Test Glazing Area -Glass Protection -Skylights -Plastic 12. Electric Underground Shear Walls; Nailing -Bolts 13. Plenums & Ducts; Clearance -Material -Support -Ins. Brace Interior/Exterior Wall Panels 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Insulation -Walls -Ceilings 15. Access & Ventilation Infiltration -Walls -Windows 16. Insulation Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 69. Stairs & Rails Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Elec. Outlets at Wood Panel, Int. & Ext. ELECTRICAL (Permit) OK except #'s 72. 23. Fixture & Transformer Clearance -Ins. Protection 73. 24. Elec. Receptacles Spacing -Lights & Switches at Doors 74. 25. Size Boxes & No. of Conductors Stapled 75. 26. Romex Installed Close to Edge of Studs & C.J. 76. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 77. 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 78. 29. Subfeed Wire Size / / ga. Cu or AI -A. C. Wire Size / / ga Cu or Al 79. 30. Range Circle / / ga Cu or At -Oven Circ. / / ga Cu or AI Insulated Neutral O Yes O No 80. 31. Service -Riser Conductors & Ground Main Disconnect 81. 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 82. 34. Smoke Detector 83. Stucco Brown -Finish Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Water Well, Disconnect, Electrical, Plumbing 35. A.C. Ducts Insulation & Support Exterior Elec. Trim, G.F.I. Receptacle -Underground 36. Vent Fan, Exhaust above insulation Ventilation Throughout House 37. Condensate Drain & Overflow, Size & Grade Glass Protection 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet Corrections from Previous Inspections 39. Attic Access & Platform if Furnace in Attic Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Date 40. Sits Proper Materials & Anchors Card B-1 Date Card B-1 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound Comments at Final: 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing >ingle & Duplex) Date FRAMING (Continued) - 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rttr. Ties- Purlin-Rolf Bac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, A r -Connector - In Garage; Above Floor -Ducts -Mach. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdri. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 82. Following Instld./Drive :] Yes ' NoMaks 7 Yes :1 No/Planters p Yes J No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance--ireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: CWNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION x 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT o: (Rev. 12/96) t 1 ' • APPLICATION AND PERMIT a - � ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER MARK AND SANDRA CONWAY TELEPHONE 9'12-1685 SQ. FT. OCC. BUILDING VALUATION 1500 81 043.00 OWNERS "UNG ADDRESS PO RON 91, PATERMIJ 99968 CONTRACTOR'S NAME FIRCITTIVE HOMES TELEPHONE 891-6992 CONTRACTORS MAILING ADDRESS 1(7149 FSPLANADE C14TCO 99973 CONSTRUCTION LENDER ' Fireplace LENDER'S MAILING ADDRESS' Total Valuation $ 81,043.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee 585.50/2 $ 270.25 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUILDINGADDRESS MIDDLE HONCUT RD, HONCUT Energy Plan Checking Fee $ $ PERMIT FEE $ 322.25 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 1 20.00 Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ XOther SPECIFY —Each Solar or heat pump water heater 23.00 Water piping 15.00 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New OX Addition ❑ Remodel ❑ Ubl'Ities ❑ Installation ❑ Other ❑ Describe Work: NEW HOME MANUFACTURED HOME ON FOUNDATION (REPLACEMENT) (SFOREMOVED) Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home IS I Gi W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service ' AOR'SS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in }j1I f c and effect. / License Class C: � Lic. No. (D� S OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compens ion Insurance, as required by Section 3700 of the Labor Cod r the performan a of work for which this permit is issued. My workers' compaosation insurance cer o is number ar Carrier Main Service TO 46.00so CCU000A WEE200A NEW CONST. DWELLING OCCUP. SO OR ADDNS. & ACC. BLDS. 3.50FT. NO qOIDT' MULTI.OUTLET 97,50 POWER APPARATUS 8 SINGLE OUTLET CIR. OUTLET OR FIXTURES 20 @ 1.00 Ex. Occup.BAL @ .50 FIXED APPLNS. OR Ex. Occup. OUTLETS RESID. Ea 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall f rthwit cc ly with those provisions. Date _X _ Sign -00 -re Applicant - ❑ OwnerVL-Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 372.25 HAZ. D. FE IMP FLOoo �/ cDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By 4 Da I l PERMIT EXPIRES ON (2 D� Dele ReceiptNo. 302567 63.00/302867/$309.25 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT Plot Plan AttacE.H. USYhed Floor Plan Attached Sant to B.D. /dc� TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance co 13 ff/ )�/(o Owner Location AP# Plan Approved for: Sewage Disposal —i—, ---'Water Supply: Public Private Well Clearance for dwelling. Other o2: �u d /1c►o� �'Lo %ar o Hold final for: Final clearance O.K. for: NOTE: Environmental 8/96 alth Specialist G 6Q� Date .....,z,,..rv,1GrF"►w+"%w:�:-�+�-tiiii-:�:'L'+1D�-%F�;.f w,,:�:J`�-`�rtw.:+�c=.f'"��v,+d'-*.�.^r+��c-:.ra..r-wr'�:^.y+�.:�'•v+...��x^�^�r'+4•r.,....,-,'f'-•;uti�, COUNTY Off' BUTTE -DEPARTMENT .OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVR ALIFORNIA 95965 - TELEPHONE (530) 538-7541 PERMIT APPLICA TION DA TA SHEET OWNER: OWNER: ASSESSOR PARCEL NUMBER: O_Z� Proposed Building Use: uilding Inspector: Date: r At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ .. All items have been submitted----------------------------------------------------------------------------- lot plans, 3/4 sets, signed by the preparer of plans. ---------------------------------------------------- omplete plans, 3/4 s ets, signed by the preparer of plans. --------------------------------------------- f4.ngineered plans, ered plans,3/4 sets, with wet signature on plans. All engineering must be shown on plans. 115. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! --------- ❑ 6. Energy Design Compliance and supporting documentation. ---------------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. --------------------------------------------------------- f2. ardous Material Form. ------------------------------------------------------------------------------------------ ufactured me attallation instructions including Tie Down Specifications.------------------ , esof $ �'' ----- �`---------------- --------- ---------------------------------------------- pact fees as shown on the attached schedule. - -------------------------------------------------------- lifornia Department of Forestry plan approval/fees. --------------------------------------------------------- lood elevation certificate. -------- - ----------------------------------------------------------- amtation and plot plan approval talth Department. ------------------------------------------- ❑ 15. City of Chico plumbing permit. -- ----------------------------------------------------------- El 16. Plot plan and business license approval from the City of Biggs. ---------------------------------------------- ❑ 17. Planning approval for (A) Use: (B) Parking: -------------------------- N C6ntact Land Development about 11 Improve ents, ❑ Drainage, El Legal Parcel. ----------------------- j' 9. Encroachment Permit forve ay (co truc o approval prior to occ pancy . j---------------- --------- 20. Pre -inspection form I D required. R 0 (Bate) ❑21. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ El 22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- ❑2 .Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- tter of signature authorization. -------------------------------------------------------------------------------- 5 ecorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- 26. Letter of intent on building use.----------------------------------------------------------------------------------- -0C) ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- 28 fist, gv ations and/or fired perms �A-------------------- � ---- ----------------------------------- 29. 33 A, ant D H. Title, �'C�tteCk to H.C.D $- --------------- 030. Other: ------- en you is: /141e lephone and hold for pickup at Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Poll tion Date: $3+: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Othe Date: By: 1. Index permit application for the above items numbered: / ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter,,by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑Bui g Division counter, by ate: Plans reviewed by: Date: Plans approved by. f Date: Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow -;Copy - Department of Development Services, Building Division. ( School District A.P. Number Property Owner Property Location r BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM I (One brm per Building) on -bl3 Subdivision Lot No. 1 Residential Development17 s Sq. Footage No of Living Mobile Home Addition/ *Supplemental to (Group R) JA— Units Installation Conversion Permit #174 € *(No foundation inspection): Com erciaUlndustrial Sq. Foo age New Addition (Including E) e�or R ofed Areas) uilding Department Representative Date A (FloorplarLs revie ed bSchool District Personnel) ,Distric Identification No. (Street Address) (City) 1 has complied with the requirements of Resolution No. representing �--square feet. LA Representative Paid by Check # /P,. Remarks: n � District certifies that (Applicant) -W. (Phone Number) n (State) (Zip Code) 3 I V by payment o $ .�. AB 2926 f Sr FULL MITIGATION) o Date f Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this proiect may be subiect to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm PRE -INSPECTION REPORT CONTRACTOR: ZONING: 4 - PRE-INSPETION FOR: &d DATE TO INSPECTOR: PERMIT HISTORY:( ) NONE ( ) AS FOLLOWS: BUILDING INSPECTOR'S REPORT Building Description: CommercialAJsage: Residential/# of Units: Currently Occupied AbandonedNacant Electric: Yes No Electric currently On Off Condition of Electric Gas: Natural Propane None Currently On Off Obvious Problems: Sanitation: Plumbing Working w,t� Well Working Potable Water Obvious SewageProblems ACTION RECOMMENDED: ISSUE: Inspector. HOLD FOR Date_ /, �va Sketch buildings on reverse and indicate location on property. a (Rev. 12/96) COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (530) 538-7541 APPLICATION AND PERMIT PERMIT h ASSESGOnPARCEL NMem 40S ZONING BUILDING PERMIT OWN R s NER9 MAN ADOnESS Q_3 RACTOR'S NAME TELEPHONE _ TEl NONE SO. FT. OCC. BUILDING VALUATION coNrRAOR �M-A11UNo • C yq CONS TRUCTION LENOEn V — LENDEn s MAILING ADDnESs Fireplace Total Valuation E ARCHRECT On ENGINEER LICENSE NO. _D!jag Fee J S 20.0 ARCHITECT OR ENGINEERS MAILING ADDRESS Permit Fee S Pian Checking Fee $ -� BUILDINGADDRESS I_ Energy Plan Checking Fee S $ PERMIT FEE S LOT NO. SUBDNIS x) SNAME PARCEL MAP PLUMBING PERMIT _ Filing Fee 20.0( USEOFSTRUCTURE SF ❑ Duplex ❑ Mobllehome Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00S / TYPE OF WORK New l/ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe ork: 00-o') Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 S - Building ;sewer 15.00 Mobile Home S I G W @20.00 PERMIT FEE S J ELECTRICAL PERMIT Filing Fee 20.00 Main Service a°OY OR LESS 200A GR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license Is In �fu1ll force end effect. // License Class T r% Lic. No. (_p � _ DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure Is not Intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. , Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST.: DWELLRq OCCUP. SO OR ADONS. i ACC. BLDS 4FT, -' WET MULTI•MEr �G 7,50 NON•nESID. PO AP70)_ a SINGLE GOWNER-BUILDER Ex. Occu . OUTLET OR20 1.00 DAL @ .50 Ex. Occup. FIxeD ESI OR Ou s ESID. R 5.00 - Tem orer S ce 23.00 Mobile a Facilities 20.00 M6 . Wkin 23.00 — - PERMIT FEE S WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -Insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit Is Issued. My workers'mpensallon Insuran a cagler and p [icy number are: Carrier Policy Number (rhe above sections need -in lot be completed If the permit is for work of a valuation -of one hundred dollars ($100) or less.) ❑ 1 certify that In the performance of the work for which this permit is Issued, I shall not employ any person In any manner so as to become subject to workers' compensation laws of California, and agree that H I should become subject to the works ' compensation provisions of section 3700 of the Labor Code, 1 shall ,0 th cc ply Wi those provisions. X Date Signature o licant - .❑ Owner Contractor ❑ Agent An OSHA perm s required for excevet ons ove .60" deep and demolition or construction of structured , r s es in heig . MECHANICAL PERMIT Filing Fee 20.00 Heating Coolin Hood 6.50 Ventilation PERMIT FEl_ $ Mobile Home Installation Fee $ Energy Inspection Fee $ ^ OCC CONST. TYPE TOTAL FEE $ Z J HAZ• D. PEES IMP I ROOD I CDF PARCEL PO HD ISSUE This permit Is hereby Issued under of the Butie County Code and/or Indicated above for which fees have I By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date _ reipt No. / i TE•D.D.S.-B.D. CA AR •ASSES n ' PINK-INSPECTOn GOLDENFIOD-APPLICAN I(Def-J ,. co LM E �i And when recorded mail lo: Building Division #7 County Center Drive Oroville, Ca. 95965 COPY of Document Recorded 12 -Sep -2000 2000-0035172 Has not been compared with original BUTTE COUNTY.RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEnGMENT FOIL RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of 'a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents ,Of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not lin led to herbicides, -pesticides, and fertilizers:. and from the pursuit of agricultural operations Including, bul-'not litnited to cultivation. plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents wn within said zones and oadjacent properly should be prepared to accept such inconvenience or discomfort from normal, necessan. faun operations. All that real properly situate in the County- of Butte. Stale of California, described as follo,s-s: Ld+s 1 1�) q a.r& � S/ as Sh0 Ler l - Ort 'Y -Q 0_nA-'41Qd �� {-I otn -u�-h ut-E -4z wht� rl�o�P vias rcco r6l Qd 'kms 4h(2, o-� of � rQC o rc�� r O-� `+1Q Cp U C-rAj-`E'er Cali SO Y mo,) C)n Mo -.r --O- V\ `3, tg�9 . i r %O k -7 O -C MCI -p5, 0-k pa_y (S) g , Date: O �� PROPERTY OWNERS: r , 6 Slate of California ) County of ) On D before npe, personally appeared d d. personallc known to me (or proved o me on the basis of Safi actory Ince) to be file persons) winose name is/arc subscribed to the within�instrumen acknons-ledged to nne 1h' the xecuted file same III bei authorized capacity(ies), and that liy Ja•isf /(heir ignature(s) on (lie instrtnnent, the person(s) or the entity upon betl alf of which the persons acted executed the inslntment. I ( ) WITNESS in • hand and off ial seal. CINDI VAGOSTIN t Cornrilhoon #1251111 Notary Pubk - CotffnrNo _ Butte County Signature Mycomm, BpiEs Feb 19, M A.P.#®ac� - O_= � e, z . May 1995 1. Owner's Name: m GL. r k 2. Assessor's Parcel Number: 3. 'Installer's Name: u�,�, I l�� `� (C) 4. Is the site currently under permit? Yes[ ] No[�j Permit No. 5 Is the site an existing site? -Yes(] Nol j (If yes, furnishtwo plot plans). 6. What is the electrical rating of the mobilehome? 100 Amperes. 7. What is the mobilehome site circuit breaker rating? R0 Amperes. 8. What is the electrical .rating of the mobilehome site? O Amperes. 9. Is the main service remote from the mobilehome site? Yes[kf No[ ] If it is, what is the rating? /,00 - Amperes. 10. Is there any other electric load to be served by the mobilehome site electric service (i.e. well, garage etc.)? Yes[ j No[' ] If yes, please identify the load and size: a) The mobile home site: Load- , U) P'4L Amperes- 3 T b) The main service: Load- Amperes - 11. Type of gas service at mobilehome site: Natural[ j Propane[ None[ ] 12. Size of gas pipe at the mobilehome site from the meter or tank: :3 inches. 13. What is the gas.pipe length from the meter or tank to the mobilehome?2�:E(ft.). 14. What is the mobilehome gas demand? B.T.�-.-v1���N� *(This information is not required if the pipe length is less th � 4 Teems al gas or less than 50 feet on propane). 10)_ %(-.,Q� I n 8.5- M Frr*,L Gid o'o'-tE%—----- —-- I / 3p , )Do House - -O JRF rei''?0V e r �7 w 6 05) 1 1n4.1'U,,% X C "o L dos -D 1 August 4, 2000 CAPITOL ENGINEERING LABORATORIES, INC. Materials Testing • Inspection • Crane Certification Subject: Soil Classification at 1313 Middle Honcut Rd. Building Pad Dear Mark, We have completed an Atterberg limits test on a sample of native material delivered to our lab. The plastic index obtained was 8, which is indicative of a non -plastic or clayey soil, and therefore not expansive. Regards, _QAPITOL ENGIN G LABORATORIES, INC. G. B ry Lotz, aY9400.016J,K* 631 Commerce Drive • Roseville. CA 95678 (916) 786-2488 • FAX (916) 786-9372 Ed Wd22 : vo a00Z vo -6nd Z226982_9% 'ON Xdd SWI ON I833N I ON9 101 I dti0 : WOdJ 06 . I ln YI 4 ro r . • 'tel I I C7 L _r PAU L 'b Q� n l�_,. �I �p � � # I• Irlt I�Ulw Q7 Sq Or � ` IL ' '• '] 1 IP ,in. a I o�i�fl,ir I U x f,7 TP Yj l n a qJ t0 C) P'n Id G7.bq Pqq npq 'nm uNq Hnlow In.inN nnnNiaana Gia Fp.:P.i mnm nn-bl-nnw L,: RELORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 05 -Oct -2000 2000-0038684 1- Has not been compared rith original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as. to its contents to all persons thereafter dealing with the real property. MARK W. CONWAY & SECUNDA Y. CONWAY REAL PROPERTY OWNEMESSOR 131 MIDDLE HONCUT ROAD MAILING ADDRESS OROVILLE, BUTTE, CA 95966 CITY COUNTY STATE ZIP SAME INSTALLATION MAILING ADDRESS, IF DIFFERENT CITY COUNTY STATE ZIP SAME UNIT OWNER (if also property owner, write'SAME') MAILING ADDRESS CITY COLI Rm STATE LP UNIT DESCRIPTION BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP 00-1965 (530)538-7541 BU D G PERMIT N0. TELEPHONE NUMBER 10/04/00 GNATURE OF LOCAL AGE YrPFFIC[kL DATE EXECUTIVE HARAES DEALER NAME (if not a dealer sale, write 'NONE') 92081 DEALER LICENSE NO FLEETWOOD 2000 ANNIVERSARY 456-3B MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMEINUMMBER IDFLY04A/B23572-ZZ13 56'X 25'8" IDA 19421/2 SERIAL NUMBER(S) LENGTH X WIDTH INSIGNIAILABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER A.P. # 028-050-007 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE -County Recorder CANARY - HCD PINK - Applicant GOLDENROD- Building Dept. BUILDING PERMIT NUMBER: 00-1965 Address or location of unit: 1313 MIDDLE HONCUT RD., OROVILLE, CA 95966 Legal Description of Real Property: A.P. #028-050-007 SEE ATTACHED (x) Mobilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: MARK W. & SECUNDA Y. CONWAY Owner's address: 1313 MIDDLE HONCUT RD., OROVILLE, CA 95966 INSIGNIA OR HUD NUMBER: IDA194241/2 SERIAL NUMBER OR V.I.N.: IDFLY04A/B23572-ZZ13 MANUFACTURER'S NAME: FLEETWOOD YEAR: 2000 OFFICIAL APPROVING INSTALLATION: DATE: 10/4/00 PHONE: (530) 538-7541 H.C.D. 513C LEGAL DESCRIPTION A.P. #028-050-007 All that certain real property situate in the County of Butte, State of California, described as follows: LOTS 124 AND 125, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "HONCUT, BUTTE COUNTY, CALIFORNIA", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON MARCH 13, 1899, IN BOOK 7 OF MAPS, AT PAGE(S) 85. Record at the Request of Mid Valley TUle & Escrow Company Order No. Escrow No. 172890-3 Loan No. WHEN RECORDED MAIL TO; MARK & SECUNDA CONWAY 1313 MIDDLE HONCUT RD. OROVILLE, CA 95966 MAIL TAX STATEMENTS TO: SAME AS A13OVE 028.050-007 a 028-050.008 I IE Nlf N U f i� I II Itll Iltl I I� I f II 1 999—imit� 157t1t3tt� Re�ccorded Official Records COW_ !y _Of CANM J. SUBS Recorder ROSMY DICKSON Assistant 82;2" 13-f4 1999 TAX KC FEE 23.40 5 Vickie Page 1 of 1 SPACE ABOVE THIS UNE FOR RECORDER'S USE DOCUMENTARY TRANSFER TAX $.23. (&S X Computed on me conetderedon ar valva of property conveyed; OR Computed on the conalderaUon or value tae@ vans or encumbrances remaUMng of time of sale. The undersigned Grantor dedares Sfgnaturs of Dedaram or determining tar -Firm Name GRANT DEED FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, THOMAS CONWAY hereby GRANT(S) to MARK W. CONWAY AND SECUNDA Y. CONWAY, HUSBAND AND WIFE AS JOINT TENANTS the real property In the UNINCORPORATED AREA County of BUTTE described as LOTS 124 AND 125, AS SHOWN ON THAT CERTAIN WHICH MAP WAS RECORDED IN THE OFfLCE OF T CALIFORNIA, ON MARCH 13, 1899, IN BOOK 7 0 STATE OF CALIFORNLVw. COUNTY OF BUTTE On APRIL, 13, 19.99 before me, DENISE TERR_IAH—NOTARY PUBLIC personalty appeared THOMAS CONWAY .. personally known to me (or proved to me an the balls of satisfactory evidence) to be the persan(s) whale names) L-4re subscribed to the within instrument and aduxWedpd to me that hdshelthey executed the same in hWWAhelr aurwrized taspacity(lea), and that by hislherlthetr eignature(s) on the Instrument the persona) or rte entiM upon ce wntcrt Qts perWI$) acted, ex the instrument WITNESd and ofi9pial seal. 1 Sisnature F , State of CWbrnla, MAP ENTITLED, "HONCUT, BUTTE COUNTY, CALIFORNI. 115 RECORDER OF THE COUNTY OF BUTTE, STATE OF MAPS, AT PAGE(S) 85. THOMAS CONWAY DSAJU 1ERRM ! 10'13983 Mb CPSI NPr.30.It Dl1SIN.ESS, TRANSPORTATMON AND HOUSING A(3L-.NCY DEPAR'T'MENT OF MOUSING AND COMMUNITY DEVELOPMENT DIVISION OF CODES AND STANDARDS REGISTRATION AND TITLING PROGRAM STATIRMENT OF FACTS NCW UNITS PLRMANCNf FOUNDATION Ccvntnerciat Coach 0 Floating Home Camper 1ltic unit is u: � Mobitehume Decal (Licetlse) No.(s) Trade Name �^ Serial No.(s) leCe�tww *d Lyous-z Z,3 Me, the undersigned, hereby slate: DEALI'K REPORT OF SALE ME ABOVE DESCRIBEU UNIT HAS BELN PIACED ON AN APPROVED FOUNDATION SYS'1'GM IN ACCORDANCE WITH 18541. OF THE IIF^.LTR AND SAVVY CODE 1/We further agree to indemnify and save harmless lbe Director of I lousing and Cuinu tnity Development, Stale. elf California, and subsequent purchasers of said trail, for any loss they may suffer resuiling from registration of the a1mve-descrilmd unit in California, ur from iVSVMtCe 01'11 C:alifrn•niu certificate of title coveriag the same. I/We certify under penalty ell' perjury that th-e`: foregoing is true and correct. Fixecuted on b V at _... ( at) (City) signature(s) 15 - M., OR 1 Printed name(s) Address_,30 City L.0 Slate IICD 476.6 (REV 9/91) Z 390d 89L8 168 0£5: Xt1d S3 40H 3t1I1f103X3: Q I 01:80 Wtj 00, 90/01 18t7'ON 31I3 - __----'— - - -- — -- GENERA T • . 1, The Contractor shall verifU all dimensions and details prior to construction and not(fU the Engineer of ani discrepancies. 2. Ail construction and methods shall be in strict conformance with the applicable provisions of the Uniform Building code, 1991 Edition, and the latest edition of the UMC, UPC, NEC, and applicable municipal, state, and Federal regulations + 3. All work is subject to building department field inspector's approval. 14. The contractor shall provide all measures necessarU to protect the structure, workmen, and all other persons during construction, 1 1p . The Contractor shall be responsible for the location of all underground facilities or other buried objects which may be encountered but which are not shown on existing utilities that ma or mag not of exi n these plans. Locations and depths o U g U U be shown on these plans theU are approximate and maU not be complete, 2. Foundation design is based upon an assumed soil bearing capacity of 1500 PSF a g p per Butte County Building Department. 3. All excavations shallbe inspected and approved bU the Building Officialficial before concrete is. oured Footings shall be at least 12 inches wide, and extend at least p g directed 12 inches into the prepared pad, or as dib the Engineer, U g , whichever is lowest. Engineered fill may be used as existing grade provided tests are presented to the Engineer of a 90% relative compaction . 14. The bottom of all footings shall be level, 5. The Contractor Shall be responsible determining the exact location of all anchor for g bolts, holdown anchors or straps, and embedments, prior to placement of concrete. " diameter X l0" long ro. Anchor bolts to be 1/2 g with T' embedment Into concrete spaced at ro'-O" o.c, maximum unless otherwise noted on plans, shearwall schedule, or details. PIER BASE OR POU12ED IN-PLACE CONCRETE FOOTING DIMENSIONS ON -CENTER SPACING PIER S G MAXIMUM PIER LOADS 0-133) SEE NOTE 1 ALLOWABLE SOIL BEARING PRESSURE ALLOWABLE 5011- BEARING PRESSURE 1500 PSF 1000 PSF 1500 PSF 2000 PSF 3000 PSF 4000 P5F 1500 1611 x 14" 12" x 12" 12" x 1211 12" x 12'' 12" x 12" 2000 ll 11 1C� x IS -" „ l2 x IC � 2" x 12" 12" x 12" 12" x 12" 2500 Ih" x l5" 12" x 15" 12" x 1211 12" x 12" E6"3" 11 7 1, x lC 811 i 12" x 18" 12" x 12" 12" x 123000 3500 ri n 24 x 21 II Ila" x 21 " it 1(0 x 1 ❑ u X 12 1 4u ll2" X 12" 4000 li " 24 x 24 " 24 x _ it Irbil „ lro x „ 18 Ii t2 x II Ih 11 112 _ x II 12 -4500 „ " 24 x 2`1 " 24 x I8 " Ir " X 20" Ira" x ' 1411 12 I x 14 5000 24 x 30 24 x 20 Ira x 23 Ila x 1Oil 12 x 15 (9000 " " 30 x 29 " 24 x " 2�E " 24 x IS" Iro" x 1811 16" x 14" 1000 " " 30 x 34 2 " x 4 28" 24" x 21" 16"" x 21" 16 II x 1, i6 8 000 32" x 3r " 301 x 2r 11 24" x 24"_ 24" x Irbil 1r 11 x KJ 18" 9000 36" x 36" 30" x 29" 30" x 22" 24" x 18" Irbil x 20" 10000 3(11 x 40" 32" x 30" 30" x 24" 24" 'x 20" Irbil x 23" noao 3ra11 x 44" 32" x 33" 30" x 26" 24" x 22" 24" x 1-1" MOBILE HOME BY OTHERS 2x4 TOP PLATE Jam_ STEEL MAiN RAIL / Irod NAiLS (@ Ib11 O.C. WOOD WEDGE SHIM 3/6" CDX OR EQUAL W/ 2x4 PONY tUALL 8d (a ro" 112" „ _ " " MASONRY BLOCK 2x4 la _x8 x06 LM STUDS AT IrbilO.C. 8d GAL „ O.C. EDGE -6 12" FIELD uN D15TURBED SOIL 2x4 PRESSURETREATED REATED 51LL .X CY d i 2x00' " -0 O.G. WITH . — A.B. c� 6 N WASHER _. 2 X 2 X 3 � THICK STEEL ..... IIII ' � � .� . _ I / — a — . UNDISTURBED SOIL - LU III . IIII U • #4 REBAR CONTINUOUS �.. TABLE II a TOP d BTM. IZ" f each end of 2x 6111 late wit a minimum o wo K I 10:� n V: Ir Al. I I Bolts shall be located within 12 0 p � 10 _P1 1i.r 1 anchor bolts ` per sill late. p p NOTES: -7. An unusual soil conditions such as organic soils, clan pockets or uncertified fills shall N.T.S. N.T.S. be brought to the attention of the engineer prior to construction. I. SEE FLOOR PLAN FDR MiNIMUM PIER CAPACITY UNDER RIDGE BEAM ` g _ 8. Clean footing excavations of debris and loose soil prior to placing concrete. SUPPORT POSTS. > o the foundation ARGE SUPPORT POST LOADS MAY REQUIRE DOUBLE PAIR APPLICATION y 9. Slope the round surface awa from footings_to direct water awa 'from , 2, L fY p g y.2" per Boot slo e• awa for 6 . and prevent water ponding next to the footings, Provide. l/ p p U (SEE. DETAIL A ON MFG. PLANS) CHECK MAXIMUM PIER CAPACITY WITH METAL p p i� g � � 10. Provide an IS" x 24 underfloor access. PIER MANUFACTURER, with all cells routed with #4 0 24" o.c. horiz. and vert. or 6" II. Wall stems mai be 8 cmu g _ - p wide concrete. 12. Provide 6" x 14" screened under floor vents per code CCD lkll Co P% ETE u; pL 4iI concrete shall have a cement factorof 5 sacks per cubic a maximumS MOBILE HOME BY OTHERS. _ s curin unless otherwise noted. u f c 2 500 si after 28: da g 4 and a minimum p y 2. Vibrate concrete around ail bolts, r e bars and Surf aces: 2„ xl x8PRE PRESSURE TREATEDFATED 3. Construction joints shall be clean and wet prior to burin concrete. BLOCK WITH SHIMS A34F AT 32 O,C. n at all other locations and 3 4 in foundations um of 1-1/2” a l be a :maxim/ . Aggregate _ size sh 1 4A W Shc�(o"11211 3 8 CDX OR EQU L troweling. / after final tr / ayed on all exposed surfaces (mmediatelU g Curing compound shall be spr p I -- 4 g_ toconfo my . _Alla reacesshall rASTM Standard C 150A cement'shall 'conform to 9g g5. 114x6 R}M _ OCKM standard C 33.Co x8 xlro MASONRY BL 'XAST - _ 2x4 PiZE53URE TREATEDSILLshall be 2 exce tCo. Unlessshown otherwise,the minimum concrete cover for reinforcing P dced direct) aa(nstearthwhere �t shall be 3 .when concrete is to be pia y g _ 1 2" x 10" A.B. �'-O" O.G. WITH UNDISTURBED SO1L _ N/S) 1n"„ ro” THiCK STEEL WASHER 2 X 2 X 3/I—� IIII— • T i MSM it]�r''� �._ — _ !II IIII °O s — IIII UNDISTURBED SOIL ... 1, All wood bearing on concrete shall be pressure treated Hem -Fir 2. Hales for bolts shall be bored with obit! / 32ito / Ia n largerer than nominal al bolt diameter. , 3. All bolt heads and nuts against wood shall bear against 2" x 2" x 3116" steel washers, unless s ecial washers are called for on plans or details. --_ 1. Retnforcing steel shall conform to the provisions of ASTM A-615 Grade 40 for #4 d smaller,_ # A ebar to be deformed and all splices shall Grade ro0 for 5 bars and larger. I1 r p ASTM A-615 9 not be less than 50 bar diameters of the larger bar. Horizontal laps in adjacent bars shall be staggered 5'-0" minimum. 2 Bolts and nuts shall conform to the provisions of ASTM A307, Grade A. FOOTING. viZE FOR INTERIOR PIERS ON -CENTER SPACING PIER S G PIER LOAD ALLOWABLE SOIL BEARING PRESSURE 1000 PSF 1500 PSF 2000 PSF ro' 2132 # 24" x 13" 12" x. 18" 1211 x !2" 81 2848 # 24" x 11" 24" x 12" 24" x 12" 10' 3553 # 24" x 22,1 24" x 15" 24" x 1211 12' 4264 # 24" x 24" 24" x 18" 24" x 14" - N U cv --_ - _ #4 REBAR CONTINUOUS _ 2 _ #4 R BAR EACH WAY c P TOP 8 BTM. t L � RE BAR TABLE I 1N DETAIL 00� �r:l T'1 P1 RrJ 1_.("\�INTEPIORN.T.S. N.T.S. ' �i 0 ` cf) o A':; # 00, LL .. UEN w 11 1. The Contractor shall verifg all dimensions and details prior to construction and notify the Engineer of any discrepancies. 2. All construction and methods shall be in strict conformance with the applicable provisions of the Uniform Building code, 1997 Edition, and the latest edition of the UMC, UPC, NEC, and applicable municipal, state, and Federal regulations 3. All work is subject to building department field inspector's approval. 4. The contractor shall provide all measures necessary to protect the structure, workmen, and all other persons during construction. e s FOUNDATION-0- 1. facdl it.ies f l underground o al 1. The Contractor. shall be responsible for the location, p or other buried ma ects Which be encountered but which are not shown on 'd objects y and depths of an existing utilities sties that ma or ma not ..:these plans. Locations a p y g y J be shown on thesep lans they are approximate and may not be complete. 2. Foundation design is based upon an assumed soil bearing capacity of 1500 PSF per Butte County Building Department.` 3. All excavations shall be inspected and approved by "the Building Official before concrete is poured . Footings shall be at least 12 inches wide, and extend at least 12 inches into there ared ad, or as directed b the Engineer, whichever is lowest. p p p y Engineered fill mag be used as existing grade provided tests are presented to the Engineer of a 90% relative compaction 4. The bottom of all footings shall be level_ 5. The Contractor shall be responsible for determining the exact location of all anchor bolts, holdown anchors or straps, and embedments, prior to placement of concrete. ro. Anchor bolts to be 1/2" diameter X 10" Tong with 7" embedment into concrete spaced at 61-0" o.c. maximum unless otherwise noted on plans, shearwall schedule, or details. " f 11 l h I i of two PIER BASE OR POURED IN-PLACE CONCRETE FOOTING DIMENSIONS MAXIMUM PIES? LOADS (LBS) SEE NOTE i ALLOWABLE SO1L BEARING PRESSURE 1000 P6F 1500 PSF 2000 PSF 3000 P5F 4000 PSF 1500 16" x 14" _ 12" x 12" 12" x 12" 12" x 12" 12" x 12" 2000 ih" x 18" ' 12" x 16" u i, 12 x 12 n " 12 x I2 u u 12 x 12 25 00 16" x 23" 16" x 15" 12" x 15" 12" x l2" 12" x 12" 3000 16" x 27" ICS" x 18" 12" x 18" 12" x 12" 12" X, 12" 3500 " " 24 x 21 " " 16 x 2l Ir „ x I6" 12" x 14" 12" x 12" 4000 2411x:24 24 x 16- x 8 16 ! 12 16 _` _U x ,t2 2 X1500 " " 24 x 27 n 24"_x 18 "` " 16 x 20 , 4 l6 x 12 x 14 5000 24" x `30" 24" x 20" 16" x 23" 16" x 15" 12" x 15" 6000 30" x 29" 24" x 24" 24" x 18" 16" x i8" 16" x 14" 7000 30" x 34" 24" x 28'' 24" x 21" t6" x 21" 16" x 16" 8000 32" x 3r " 30" x 26" 24" x 24" 24" x 16" loll x 18" 9000 36" x 36" 30" x 29" 30" x 22" 24" x 18" i6" x 20" 10000 36" x 40" 32" x 30" 30" x 24" 24" x 20" t6" x 23" 11000 36" x 44" 32" x 33" 30" x 26 24 x 22 24 x 17 MOBILE HOME BY OTHERS 2x4 TOP PLATE T"___�� r3 -EL-- STEEL MAIN 2AlL I NAILS nu 16" O.C. WOOD WEDGE SHIM 3/63" CDX OR EQUAL W ,� " 2x4 PONY WALL Sd to 6" 112" 6x8 xIrb MASONRY BLOCK ; " AT 6 D.C. . STUDS J " O.C. EDGES A V. C� 6 E G Sd G L _12 FIE[_D 1= L UNDISTURBED SOIL X .2x4 P RESSUIZE TREATED SILL 1 2'x10 A.B. (@ &'-0" O.C. WiTH N " " - — X 2 X 3 16 THICK STEEL WASHER 2 / � .= a .• °IIII= Q UNDISTURBED SOIL IIII J U " 1 N - #4 REBAR CONTINUOUS TABLE P TOP d BTM. 1 2,, is shall be located within 12 of each endo 2x si ate wit a m n mum pp-� 9 Boi p � 10 T"'t 1.J� �� �1 � 1 anchor bolts per sill plate. I 1N 2 7. An ° unusual soil conditions such as organic soils, clay pockets or uncertif led fill✓ shall NOTES: � N.T.S. N.T.S. o be brought to the attention of the engineer prior to construction. I. SEE FLOOR PLAN FOR MiNIMUM PiER CAPACITY UNDER RIDGE BEAM g a - 8. Clean footing excavations of debris and loose sofl. prior. to placingconcrete. SUPPORT POSTS. > 9. Slope the ground surface away from footingy s to direct water awa from the foundation 2. LARGE SUPPORT POST LOADS MAY REQUIRE DOUBLE PAIR APPLICATION � . and prevent water ponding next to the footings. Provide 1/2" per foot slope aw,19 for 6'. (SEE DETAIL A ON MFG. PLANS) CHECK MAXIMUM PiER CAPACITY WITH METAL - p p g 10. Provide an 18" x 24" underfloor access. PiER MANUFACTURER. L " s routed with #4 (a 24" o.c. horiz. and vert. or 6"11. Wall sterns may be S cmu udth all cel( g wide concrete. 12. Provide roll x 14" screened under floor vents per code 1. All wood 'bearing on concrete shall be pressure treated Nem -Fit ON -CENTER PIER SPACING PIER '" LOAD - AL-LOWABLE 501E BEARING PRESSI.IRE 1000 PSF 1500 PSF 2000 PSF ro' 2132 # 24" x 13" 12" x l8" i. ,m o f All concrete shall ave a cement factor of 5 sacks p'er cubic gard, a maxdurum .i 2848 # MOBILE HOME BY.OTHERS 24" x 12" 411 and aminimum fc_2 500 psi 2S d ascu in unlessof erwise noted. 10' 3553' # 2. around all .bolts rebar s and surf aces. Vibrate 'concreteURE " " " TREATED 2x6 x8 PRESSURE 12' 4264 # 3. 4. . o concrete. et dor -to urdn a and w r" s all be clean Construction joints h Constru p pouring.�' JBLOCK locations in foundations and 3 4 at all other 1 ate size shall be a maximum of 1-1/2" / A re�� Aggregate 24" x 14" RIMS WITH SHIMS A34F AT 32 ' D.C. " troweling. surfaces lmmediatel after final tr g Curia compound shall be s ra ed on all exposed y g p p yyC-150,A conform to CDX OR EQUAL W 8d 0 6 12 �.------- 3/S / / • 5. All cement shall conform to ASTM Standard l 1 aggregates shall 4x6 RIM ASTM standard C-33. hall ..2x4 cin shall be 2" -except Unless shown otherwise the minimum concrete cover for reinforcing " OCK 6 x8 x16 MASONRY B� . X +r PRESSURE TREATED 511 -L - I• when concrete is to be placed directly against earth where it shall be 3 _ 0 UNDISTURBED SOIL = , 1 < CO 1/2 x loll A.B. a rol-011 O.G. WITH �4 cel 2" X 2" X 3/16" THiCK STEEL WASHER WOOD: TABLE _ - °III) I.UNDISTURBED SOIL - 2 Holes for bolts shall be bored with a bit 1/32" to I l6" larger than nominal bolt diameter. 3. All bolt heads and nuts against wood shall bear against 2" x 2" x 3/16" steeiwashrs, unless special washers are called for on plans or details. STEEL! steel shall conform to the rovisions of ASTM A-615 Grade 40 for #4 d smaller, L Reinforcing p ASTM A-615 Grade 60 for #5 bars and larger. All rebar to be deformed and all splices shall not be less than 5 0 bar diameters of the`larger bar. Horizontal laps in adjacent bars shall be . staggered 5'-0" minimum. 2. Bolts and nuts shall conform to the provisions of ASTM A307, Grade A. FOOTING 51ZE FOR INTERIOR PIERS ON -CENTER PIER SPACING PIER '" LOAD - AL-LOWABLE 501E BEARING PRESSI.IRE 1000 PSF 1500 PSF 2000 PSF ro' 2132 # 24" x 13" 12" x l8" 12" x 12" 8' 2848 # 24" x 17" 24" x 12" 24" x 12" 10' 3553' # 24" x 22" 24" x 15" 24" x 12" 12' 4264 # 24" x 24" 24" x 18" 24" x 14" J* AIM - 2 U UJ #4 REBAR CONTINUOUS - #4 REBAR EACH WAY o TOP 4 BTM. m _ 1211 TABLE I TAIL �001'tNG 1� 1 INT � N.T.S. N.T.S. Design: JSP Checked: JMR Date: AUGUST, 2000 �� Job No. .� p, 17 ®, Sheet: Owl) of i Sheets Cf)1 ;. 1 +r I• �. 0 LL 1 < CO Design: JSP Checked: JMR Date: AUGUST, 2000 �� Job No. .� p, 17 ®, Sheet: Owl) of i Sheets