Loading...
HomeMy WebLinkAbout028-240-018028018 PERPIIT#94-3019 MCGOWAN, ROSS W. 95 GIPSOW S RD., BANGOR REPAIR & REMODEL SIG ROOM/SF 028-210-018 PER`fIT#95-2726 McGOWAN, Ross W. 95 Gipson's Rd., Bangor���" 1st Renewal BP#94-3019 B08.0810 028-240-018 MISCELLANEOUS Private Garage/Shop DETACHED GARAGE 24X20=:480 SQ.I 95 GIPSONS RD MCGOWAN, ROSS BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR): (530) 538-4365 OFFICE: (530) 538-7541 FAX#: (530) 538-2140 ONLINE PERMIT/RENEWAL PAYMENTS: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 95 GIPSONS RD Owner: Permit NO: B08-0810 APN: 028-240-018 MCGOWAN, ROSS Issued Date: 07/17/2008 By KCG Permit type: MISCELLANEOUS P O BOX 161 Subtype: Private Garage/Shop BANGOR, CA 95914 Expiration Date: 07/17/2009 Description: DETACHED GARAGE 24X20=480 S, (530) 679-1201 Occupancy: Zoning: U Contractor Applicant: Square Footage: MCGOWAN, ROSS Building Garage RemdUAddn P O BOX 161 480 BANGOR, CA 95914 Other Porch/Patio Total (530) 679-1201 480 FEE INFORMATION DBEH Building Review Fee $78.90 DBF Garage -Wood Frame Plan Che $241.16 DBFIRE Fire Inspection (SRA) $107.00 DBFIRE Fire Inspection (SRA) $107.00 DBFIRE SRA Fire Plan Review (S $107.00 DBMSC Garage/Shop/Strge Wood F $361.74 DBOMSC Fire Safe Standards Rev $118.98 Total Charged: $1,122.93 Fees Paid: $1,122.93 DBSMIP Residential $1.15 Balance Due: $0.00 Receipt No: B8005 `LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractors License Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractors License Law [Chapter 9 (commencing with Section 7000) is in full force and effect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects X 07/17/2008 the applicant to a Nil penalty of not more than five hundred dollars [$500]; Please eck one of the following: Contractor's Signature Date I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE `'., WORKERS' COMPENSATION DECLARATION COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR ` OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of the property, who builds or improves thereon, and who does I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: the work himself or herself or through his or her own employees, provided that such improvements ❑I HAVE AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, ❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED as required by ❑ CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Professions Code: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. The Contractors License Law dows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors License Law.). Cartier: Policy Number: Exp. Date: (This section, need not a comp eled if the permit is oror on�llars ($100) or ess. I AME M)un r Section B. 8 P.C. for this reason: ERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws California, d agree that if I should become subject to the workers' X A-,-,07/17/2008 compensation v,si ns of Sect, 700 of the Labor Code, I shall forthwith comply with those Owner's Signature Date rovisions X 07/17/2008 I hereby certify that I have read this application and state that the above information is cored. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CML FINES UP TO ONE injury, including death, and property damage caused by, arising out of, or in any way connected with HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, the issuance Of ' er ,t. I her y acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND e or Occup y a sidew , street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. ove i ned property for inspection purposes. I hereby certify that I am the ;Oeowne�d to act on the property owners behalf. u/, e ZA_# 07/17/2008 ate ;<� ,' �;�„_CONSTRUCTION LENDING AGENCY 1 HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name of P SIGN] Prin Date the performance of the work for which this permit is issued. (3097 civ. code) Owner Contractor OR; E]Agent for Owner DAgent for Contractor FILE COPY Lender's Address City State Zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION* OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds PLEASE PRINT CLEARLY PERMIT NO. 0019 GI O BIN # "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. OWNER INFORMATION Last Name�lil�/' First Name 717— �5 Ma" ddr S City �v��0�p Statee/1 Zip ,5?5,f1 Phone r�D Fax E-mail APPLICANT INFORMATION CONTRACTOR Name "A�L—.� Address Zip( !71 City Fax State Zip Phone Fax E-mail Lic. # Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name City D/ Address Zip( !71 City Fax State Zip Phone Fax E-mail State License Number APPLICANT INFORMATION Name Address City D/ Statex? ( Zip( !71 PhoneD 3 ? % 1Z 0 1 Fax E-mail i PROJECT LOCATION AP# v� �' a yC� 0 f e PropertyAddress95 1-071 City>��'/tl�O/L. e s� WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than licensed contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WOY. Q/v z":w Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use onl : Zoning Flood Zone SRA reDl No Occ. ., Type Const. A J 601- California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue, Oroville CA 95965 (530) 538-7888 Office, (530) 538-2105 Fax Reference Number: B08-0810 Date: 05/02/2008 Location: 95 GIPSONS RD By: TMP Parcel Number: 028-240-018 Sub Type: Private Garage/Shop Owner Name: MCGOWAN, ROSS Phone: (530) 679-1201 Description: DETACHED GARAGE 24X20=480 SORT. To meet the requirements of Government Code section 51182 and Public Resource Code 4291, Butte County requires a pre -construction inspection to pro -actively provide the below building and site requirements to the property owner. Your property is located within the State Responsibility Area (SRA) of Butte County. All development within the SRA is required to meet the below requirements: ✓ Public Resources Code 4290 ✓ Public Resources Code 4291 ✓ California Building Code, Chapter 7A ✓ Butte County Improvement Standards Requirements prior to scheduling the pre -inspection: ✓ Full plan submittal to Butte County Development Services -Building Division ✓ Driveway and building pad must be identified on site ✓ Structure location must be staked out on the building site Requests for inspections shall be made a minimum of 72 hours in advance by calling the Fire Prevention Bureau's 24 hour inspection line at (530) 538-6226, (When the recording comes on, enter the extension number). For the pre -inspections, the property owner or authorized agent is required to meet the inspector at the construction site with two hard copies of the site plan. I have read and understand the above pre -inspection requirements. 05/02/2008 Date Signature All of the Fire Safe Requirements are posted on the Butte County Fire Department website at http://butterire.org/Fireprevention/protplan/protplan.html Rev'd 5/7/07 FILE Butte County Department of Public Works J. MICHAEL CRUMP, DIRECTOR LAND DEVELOPMENT DIVISION Storm Water Managment Program 7 County Center Drive Oroville, CA 95965 (530) 538-7266 Telephone (530) 538-7171 Fax www.buttecounty.net/dds 0 O 0 0 0 National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgment [LESS THAN 1 ACRE 1 Reference Number: B08-0810 Date: 05/02/2008 Location: 95 GIPSONS RD By: TMP Parcel Number: 028-240-018 Sub Type: Private Garage/Shop Owner Name: MCGOWAN, ROSS Phone: (530) 679-1201 Description: DETACHED GARAGE 24X20=480 SQXT. By signing below, I the project owner/owners' agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site buildouts of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the state of California Regional Water Quality Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for this project that disturbes one acre or more of land may result in revocation of grading and/or other permits or other santions provided by law. Signed: f'L' Date: 05/02/2008 Title: a w4-1- C FILE BUTTE COUNTY FEE SUMMARY 7 County Center Drive Oroville, CA 95965 Permit Number: B08-0810 Department of Development Services Phone (530) 538-7541 Fax (530) 538-2140 Job Address: 95 GIPSONS RD Contractor: Printed: 05/02/2008 12:02 pm Fee Description Account Number Fee Amount Paid Date Pmt Amt DBEH Building Review Fee 0021-540013-4614901-1010 $78.90 05/02/2008 $78.90 DBFIRE Fire Inspection (SRA) 0100-450001-4617240-1010 $107.00 0100-450001-4617240-1010 $107.00 05/02/2008 $107.00 DBOMSC Fire Safe Standards Rev 0010-440001-4210500-1010 $118.98 DBFIRE SRA Fire Plan Review (S 0100-450001-4617240-1010 $107.00 05/02/2008 $107.00 DBMSC Garage/Shop/Strge Wood F 0010-440001-4210500-1010 $361.74 DBF Garage -Wood Frame Plan Che 0010-440001-4210500-1010 $241.16 05/02/2008 $241.16 DBSMIP Residential 1001-0-280-1011298 $1.15 Printed By: Tammie Powell 19122.93 $534.06 Balance Due: $588.87 At the time of permit application, I was dvised the above fees are required prior to issuance of the permit. These feescan duri a plan checking process. Signature: Date: 05/02/2008 Pursuant to Government code Section 66020, you are hereby notified those items listed above may have been imposed on your project. You have 90 days from the date of approval of the project or from the impostion of the above referenced items during which you may request a protest. The requirments for a protest are specified in Government Code Section 66020(a). Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds **PERMIT APPLICATION DATA SHEET** Reference Number: B08-0810 Date: 05/02/2008 Location: 95 GIPSONS RD By: TMP Parcel Number: 028-240-018 Sub Type: Private Garage/Shop Owner Name: MCGOWAN, ROSS Phone: (530)'679-1201 Description: DETACHED GARAGE 24X20=480 SQ.FT. zz The above permit application has the following Clearances requXan to permit issuance lease contact each department indicated below regarding specific requirements pertaining to youpplication. Yes No SEWER DISTR ❑ Thermalito Irrigation District, 410 Grand Avenue, Oro965 530) 533-0740❑ LOAPUD, 1960 Elgin Street, Oroville CA 95966 - (530)❑ ❑City of Chico, PO Box 3420, 411 Main Street, Chico C30) 879-6700 n\DADYQ.e.DTi!"DTiATTn`TQ IIJ�J ❑ ❑ Chico Area Recreation District, 545 Vallombrosa, ico CA 95926 - (530) 895-4711 Durham Park &Recreation District, 9447 Mi ay, Durham CA 95938 - (530) 345-1921 Feather River Recreaction & Park Distri , 1200 Myers Street, Oroville CA 95966 - (530) 533-2011 Paradise Parks & Recreation, 6626 S ay, Paradise CA 95969 - (530) 872-6393 Other: i hen filed, this application and all supporting material becomes subject to the California Public Records Act. All public formation related to this application is subject to public inspection and will be posted on the County's website for electronic access. Signature of Applicant: FILE Date: 05/02/2008 / SCHOOL DISTRICTS ❑ Biggs Unified School District, 3 0 B Street, Biggs CA 95917 - (530) 868-1281 Chico Unified School Distr' , 1163 East 7th Street, Chico CA 95926 - (530) 891-3006 Durham Unified Schoo istrict, 4920 Putney Drive, Durham CA 95938 - (530) 895-4675 Gridley School Dist 'ct, 429 Magnolia, Gridley CA 95948 - (530) 846-4723 Marysville Schogl District, 1919 B Street, Marysville CA 95901 - (530) 741-6000 1 entary School District, 2795 Yard Street, Oroville CA 95966 - (530) 532-3000 OrovillFUnifl Oroviln High, 2211 Washington Ave, Oroville CA 95966 - (530) 538-2300 Ext:105 Paradied School District, 6696 Clark Road, Paradise CA 95969 - (530) 872-6400 OTHER corded copy of Agricultural Acknowledgment Statement- See Attached Instructions ❑ City of Biggs Planning Department, 3016 Sixth Street Biggs CA 95917 - (530) 868-5447 Other: Other: i hen filed, this application and all supporting material becomes subject to the California Public Records Act. All public formation related to this application is subject to public inspection and will be posted on the County's website for electronic access. Signature of Applicant: FILE Date: 05/02/2008 Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds NOTICE TO BUILDERS" Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things you can do to expedite your permit: O Make sure your application is complete. 0 Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit. A permit may be renewed (for a fee) prior to expiration an indefinite number of times, provided construction progress has been documented by the Building Division during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY" Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications, if the permit has not issued, but not after 180 days from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge to process the refund application will be assessed. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at h!W:Hmunicipalcodes.lexisnexis.com/codes/butteco/ "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Reference Number: B08-0810 Date: 05/02/2008 Location: 95 GIPSONS RD Parcel Number: 028-240-018 Owner Name: MCGOWAN, ROSS Phone: (530) 679-1201 Description: DETACHED GARAGE 24X20=480 Sq,FT. Signature of Applicant: Date: 05/02/2008 FILE Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds OWNER -BUILDER INFORMATION An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: ° If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $500 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. ° If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal ° income tax withholding, federal social security taxes, workers/ compensation insurance, disability insurance costs, and unemployment compensation contributions. There may be financial risks to you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. ° For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through thier own employees, without a license contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractor is to secure an "owner -builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board's automated telephone information system at 1-800-321 -CLSB (2752) or by accessing thier website at www.CSLB.ca.gov. PLEASE COMPLETE AND RETURN THE ENCLOSED OWNER -BUILDER VERIFICATION FORM SO THAT WE CAN CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED UNTILL THE VERIFICATION IS RETURNED. OWNER BUILDER VERIFICATION PLEASE COMPLETE THIS FORM AS REQUIRED BY THE STATE OF CALIFORNIA (SENATE BILL NO. 831 EFFECTIVE JULY 1, 1980). NO BUILDING PERMIT WILL BE ISSUED UNTIL THIS VERIFICATION IS RECEIVED. 1. I PERSONALLYORTO PROVIDE THE MAJOR LABOR AND MATERIALS FOR CONSTRUCTION OF THE PROPOSED PROPERTY IMP�ROVEMEN(OR NO) 2. (06 VE NOT) SIGNED AN APPLICATION FOR A BUILDING PERMIT FOR THE PROPOSED WORK. 3. I HAVE CONTRACTED WITH THE FOLLOWING PERSON (FIRK TO PROVIDE THE PROPOSED CONSTRUCTION: NAME ADDRESS CITY, PHONE CONTRACTORS LICENSE NO 4. I PLAN TO PROVIDE PORTIONS OF THE WORK, BUT I HAVE HIRED THE FOLLOWING PERSON TO COORDINATE, SUPERVISE, AND PROVIDE THE MAJOR WORK: NAME ADDRESS CITY, PHONE CONTRACTORS LICENSE NO 5. I WILL PROVIDE SOME OF THE WORK BUT I HAVE CONTRACTED (HIRED) THE FOLLOWING PERSONS TO PROVIDE THE WORK INDICATED: NAME ADDRESS PHONE TYPE OF WORK Description: DETACHED GARAGE 24X20=480 SQ.FT. Reference Number: B08-0810 Applicant Name: MCGOWAN, ROSS Owner's Name: MCGOWAN, AP # : 028-240-018 i Signature of Property Owner: I y� Date: 10,_ — y 8 „w.�. APPROVAL pIV,SION - BUILDINte. G P� 0 Da Other: 3OT— chid 14 . smit CONN IIJILDINC s APPR4 I f m f Vt 'jI 40 A A; V 1.4 I . 'lit OVA At qX' -y-.- it j; -.Vp v • JAI "LVMVINAC 'If f 4 1 :k. �1.1 " Oft • Vt 'jI 40 A A; V 1.4 I . 'lit OVA At qX' -y-.- it j; -.Vp v • JAI "LVMVINAC 'If f 4 1 :k. �1.1 " Oft — - ------------- BANGOR 7ISN-R.5E. D's. a ml, 2e. 2; L i TP 20-24 27 E;- 40C - 44 .4A AC 474 AL--- r3i _k7) MIA- — # 14, 0, X 6• -Vc- #r zcw.. j� 17 sz.46 1 PODS 4C .04 e IQ I PAIU-e 44 c4 1 0 Id TY4Ac 4 AC "0 A its W4 39 POW -8. to XJVAC W t Hi E ` \. C2J �� , f e t jul. 23 m i JWSE AdRCZL 4RE MR 4SSE9Sh0-4n'PlWMU or's Map No. Z8 - 2 4 ONLT AND AW- bArO7- CQXrin/M kr"L PAPat.& County of Butte; Cojif. TOWN OF SAWOR M.O. R. UK 7 PG. 77 ..... ---------- 4 el AV, FDM FACTORY DIRECT METAL 5625 EASTSIDE RD. REDDING CA, 96001 24' x 20' x 9'-0" Eave Height . Steel Storage Shed (5'-0" o.c. Frame Spacing) PROJECT INFORMATION OWNER NAME: ROSS MCGOWEN PROJECT ADDRESS: 95 GIPSON RD BANGOR, CA 95914 SHEETINDEX I- COVER SHEET 2-3 GENERAL NOTES 4- FOUNDATION PLAN 5 -ROOF FRAMING PLAN 6-FRONT/BACK WALL FRAMING & TYP. FRAME ELEV. 7 -TYPICAL SIDE WALL FRAMING/ELEV. 8-9 CONNECTION DETAILS 10- MISC. INFORMATION DESIGN LOADS: DEAD LOAD:5 PSF LIVE LOAD: 20 PSF SNOW LOAD: 0 PSF (ROOF) WIND LOAD: 85 MPH EXP C r-IZ-E- MCGOWEN �us FACTORY DIRECT METAL Date: APR 08, 2008 2008 STEEL STORAGE SHEDSCALE: AS SHOWN - COVER SHEET 1 2414 N. 1325 E. LEHI, UT 84043 P: 801.768.0361 F: 801.768.0362 ROSS MCGOWEN Of 10 r-IZ-E- �r• S. STATEMENTS 1. THESE CONSTRUCTION DRAWINGS AND SPECIFICATIONS ARE FOR BUILDING PERMIT EVALUATION ONLY. THE CONTRACTOR OF RECORD IS RESPONSIBLE FOR ERECTING THE STRUCTURE IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. GENERAL NOTES LODESIGN CRITERIA: 1.1 DES/GN CODES & REFERENCES 2007 Edition of the California Building Code Steel Allowable Stress Design, Ninth Ed. (AISC) Concrete Reinforced Concrete r Design Handbook (ACI) Ultimate Strength Design Handbook (ACI) 1.2 DESIGN LOADS Dead Load: Structure Weight Live Load: CBC Sec. 1607 Wind Load: 85 mph, Exp. c Snow Load: 0 psf 1.3 DESIGN MATERIALS & STRESSES Steel Tubing Manufactured per ASTM -A500 Carbon Steel 16-22 Gauge - cold rolled steel 16-7 Gauge - hot rolled steel Hot Dipped Galvanized ASTM A-123 and ASTM A-153 Bolts Anchor Bolts: ASTM A-36 or better Machine Bolts:ASTM A-307 or better Reinforcing Steel ASTM A -615-76A Grade 40: #4 bars and smaller Fy = 40,000 psi Grade 60: #5 bars and larger Fy = 60,000 psi Concrete Normal Weight F'c = 2500 psi in 28 days Soil Foundations have been proportioned based on an allowable soil bearing value of 1000 psf (w/ 1/3 increased of seismic) in accordance with the 2007 CBC. FACTORY DIRECT METAL v� r •�k �` STEEL STORAGE SHED NOTES 2414 N. 1325 E. P: 801.768.0361 LEHI, UT 84043 F: 801.768.0362 ROSS MCGOWEN UTTE COUNTY 3UILDINC+VjSj0h t APPROVE Date:APR 08, 2008 SCALE: AS SHOWN 2 of 10 1. LOGENERAL NOTES 1.1 CONCRETE SPECIFICATIONS I . All concrete shall be normal weight and attain a minimum compressive strength of 2500 psi in 28 days. All concrete edges, comers, and intersections shall be tooled or chamfered I" whether or not shown in the drawings. 2. The maximum concrete slump shall be: Slabs .... 3" +/- I" All other work..... 4" 3. The minimum cement content shall be 5 '/z sacks per cu yard and shall be a standard brand type 1I, low alkali, per ASTM C-150. 4. Any water reducing agents added shall be used to reduce the water/cement ratio. 5. Aggregate shall conform to ASTM C-33. Maximum aggregate size shall be I" U.0. N. Use 3/4" aggregate for slabs on grade. 6. Anchor bolts to be full diameter, cut thread made from ASTM A-36 steel by an American manufacturer and installed per "Lateral Requirements" on the following pages. 7. Curing: Freshly deposited concrete shall be protected from premature drying and excessively hot or cold temperatures. And shall be maintained with minimal moisture loss at a relatively constant temperature for the period of time necessary for the hydration of the cement (typically 7 days) 8. Special inspection is NOT required of the footing concrete. 1.2 CONCRETE REINFORCING SPECIFICATIONS 1. All reinforcing steel shall be continuous. Splices in reinforcement shall NOT be made at or near points of maximum stress. Splices shall be lopped not less then 30 bar diameters and in no case less then 24". Reinforcing bars shall have minimum bend radius of 6 times the bar diameter. Bars shall not be heated to facilitate bending. Once bent, steel shall not be straightened. 2. Reinforcing bars to be deformed bars conforming to ASTM A -615-76A: #3 & #4... Grade 40; #5 & larger... Grade 60 3. All reinforcing steel, shall be accurately positioned and adequately tied, using proper chairs and bolsters. Nails in wall or stem wall forms will not be acceptable. Supports and chairs placed against exposed surfaces shall be galvanized or provided with plastic feet. 4. Concrete cover over reinforcing is required as follows: 3"... where concrete is exposed to and cast against earth. 2"...where concrete is exposed to earth but cast against formwork. 1 '/2"...where not exposed to earth or weather. 1.3 SOIL SOECIFICA TIONS 1. Minimum required soil bearing (DL+LL) to be 1500 psf. 2. Expansive index = (assumed* / from report) *verification may be required by building official 3. 1t is recommended that on building sites exhibiting characteristics of instability, a soils investigation be performed (unless waived by the local building review agency). Any deviation from the design values shall be brought to the engineers' attention. 4. All required fill and backfill shall be compacted to at least 90% of maximum density unless otherwise noted on a soils report. 1.4 STEEL SPECIFICATIONS 1. All structural steel plates, bar, angles and channels shall conform to ASTM A36 Standards. 2. All steel tube products shall be manufactured per ASTM -A500 Grade A-1008 and 1010 Carbon Steel Grade B-1010 thru 1022 Carbon Steel/ 15 gauge and heavier Grade C-1015 thru 1022 Carbon Steel/ 15 gauge and heavier 3. Carbon Steel used shall conform to the following: 16 gauge - 22 gauge (cold rolled steel) 16 gauge - 7 gauge ( hot rolled steel) 4. Wall thickness: Cold rolled tubing (see table 9 of ASTM A-513) Hot rolled tubing (see table 6 of ASTM A-513) 5. Bending Radius: (Minimum Workable) 2 % to 3 times the outside diameter (round) 3 %z to 5 times the outside dimensions (shapes) FACTORY DIRECT METAL STEEL STORAGE SHED NOTES 2414 N. 1325 E.P: 801.768.0361 LEHI, UT 84043 I F: 801.768.0362 ROSS MCGOWEN BUTTE COUNTY MILL G" 0"NISION APPROVED Date: APR 08, 2008 SCALE: AS SHOWN 3 of 10 L� 7 o . a1- - ----------- FOUNDATION PLAN SCALE: 1/8" = 1'-0" LEGEND X/" ITW REDHEAD WEDGE ANCHOR 20 RECT. TUBE— SEE PLAN o 2x2 SQUARE TUBE— SEE PLAN EE PLAN —1�STEV WALL ,-SLAB ON GRADE WWF 6/6/10/10 FOUNDATION SECTION A -A SCALE:NTS (WHERE A APPUCABLE) LAB (WHERE VPPUUI'L'E BARS 0 16' D.C. HORIZ. 2*x3" POST DIA. ITW/REDHEAD WEDGE ANCHOR 4 BARS 0 24" D.C. VERT. SEE FOUNDATION PLAN FOR LOCATION 4 BARS x CONT. 1-9/16" MIN. S .S EE PLANS EDGE DIST. OITW/REDHEAD WEDGE ANCHOR SCALE: NTS FACTORY DIRECT METAL Date:APR 08, 2008 STEEL STORAGE SHED SCALE: AS SHOWN FOUNDATION PLAN 4 2414 N. 1325 E. P: 801.768.0361 LEHI, UT 84043 1 F: 801.768.0362 ROSS MCGOWEN 13LJITC-7 P.01 !RffV— of io 3UILDING-DIVI -81 0%, APPROVED BUILDING DIVISION, tSAU& WALL rRAMING CALE: 3/16" = I'-0" 1 6 9 /1-1\9 r --ROOF DECKING I 8 x c� W Z Q W a _ , CD 10'-0" X 8'-0" 2 o GARAGE DOOR cl, Cl9 W L DECKIN 288.00" 24'-0" FRONT WALL FRAME SCALE: 3/16" = I'-0" I YYICAL INTERMEDIATE FRAME SCALE: 3/16" = I' -0" N FACTORY DIRECT METAL Date: APR 08, 2008 a� STEEL STORAGE SHED SCALE: AS SHOWN COVER SHEET 2414 N. 1325 E. I P: 801,768.0361 LEHI. UT 84043 F: 801.768.0362 ROSS WILDING DIVISION, APPROVED 6 of 10 RIGHT SIDE WALL FRAMING SCALE: 3/16" = V-0" DECKING LEFT SIDE WALL FRAMING SCALE: 3/16" = V-0" ;1 w FACTORY DIRECT METAL Date: APR 08, 2008 �xU.y STEEL STORAGE SHED SCALE: AS SHOWN TYPICAL SIDE WALL 7 2414 N. 1325 E. I P: 801.768.0361 FRAMING/ELEV. LEHI, UT 84043 F: 801.768.0362 ROSS MCGOWEN ''rr= Of 10 BUILDING DIVISION APPROVED 6'x1 )"x18 GA. B-15 BRACKET W/ MIN.(2) /1121" TEK SCREWS TO EACH MEMBER. ONE BRACKET ON EACH SIDE OF CONNECTION 2"z3' VERTICAL UNIT r -VERTICAL TO RAFTER DETAIL SCALE: NTS TRIM BRACKET TO SLOPE OF RAFTER @DOOR HEADER DETAIL SCALE: NTS 7'x5 J"x18 GA. 8-57 BRACKET W/ MIN.(6) #12x1' - TEK SCREWS TO EACH TRIM BRA t" COLLAR TIE 9"x 9"x18 GA. 8-15 BRACKET W/ MIN.(2) /12x1" TEK SCREWS TO EACH MEMBER. ONE BRACKET ON' x3" HEADER EACH SIDE OF CONNECTION 9"x 9"x18 1 BRACKET W/ MIN.(2, TEK SCREWS MEMBER. ONE BRACKET ON EACH SIDE OF CONNECTION VERTICAL TO HEADER DETAIL SCALE: NTS ,TRUSS DETAIL ,& SCALE:NTS CAL UNIT i1B- TTOM CHORD CONNECTION DETAIL SCALE: NTS 2414 N. 1325 E. LEHI, UT 84043 1.5'x1.5" TUE DCMER BRACE DETAIL SCALE: NTS via ACTORY DIRECT METAL Date: APR 08, 2008 STEEL STORAGE SHED SCALE: AS SHOWN CONNECTION DETAILS P: 801.768.0361 F: 801.768.0362 ROSS MCGOWEN; A d ou SUILD ►1� !II APPROW ED VERTICAL UNIT 8 of 10 �-2'x3" HEADER / 1'x5 j"x18 GA. 8-57 BRACKET W/ MIN.(2) #120" TEK SCREWS TO EACH MEMBER. ONE BRACKET ON EACH SIDE OF CONNECTION "x3" VERTICAL UNIT TRIM BRACKET TO SLOPE OF RAFTER @DOOR HEADER DETAIL SCALE: NTS 7'x5 J"x18 GA. 8-57 BRACKET W/ MIN.(6) #12x1' - TEK SCREWS TO EACH TRIM BRA t" COLLAR TIE 9"x 9"x18 GA. 8-15 BRACKET W/ MIN.(2) /12x1" TEK SCREWS TO EACH MEMBER. ONE BRACKET ON' x3" HEADER EACH SIDE OF CONNECTION 9"x 9"x18 1 BRACKET W/ MIN.(2, TEK SCREWS MEMBER. ONE BRACKET ON EACH SIDE OF CONNECTION VERTICAL TO HEADER DETAIL SCALE: NTS ,TRUSS DETAIL ,& SCALE:NTS CAL UNIT i1B- TTOM CHORD CONNECTION DETAIL SCALE: NTS 2414 N. 1325 E. LEHI, UT 84043 1.5'x1.5" TUE DCMER BRACE DETAIL SCALE: NTS via ACTORY DIRECT METAL Date: APR 08, 2008 STEEL STORAGE SHED SCALE: AS SHOWN CONNECTION DETAILS P: 801.768.0361 F: 801.768.0362 ROSS MCGOWEN; A d ou SUILD ►1� !II APPROW ED VERTICAL UNIT 8 of 10 VERTICAL PI CORE PIN MADE FROM CORE 1-3/4' x 2-3/4' 14 GA STEEL TUBING BASEPLATE MADE FROM 2' K 3" 14 GA. CORE PIN WELDED TO--J//' O GALVENIZED STEEL TUBING THE 2'x3' BASEPLATE rZVERTICAL TO RAFTER DETAIL SCALE: NTS 1-J/. 10 GA. STEEL %1DOOR HEADER DETAIL SCALE: NTS 1-3/4" x 2-3/4" STEEL 14 GA. STEEL CORE INSERT SCREWS 2"x3" VERTICAL UNIT (7) �VERTICAL TO HEADER DETAIL SCALE: NTS 1-3/4" x 2-3/4" 10 GA. STEEL CORE INSERT 'w VERTICAL UNIT 0,—"YTRUSS DETAIL SCALE:NTS SCORNER DETAIL'� -EAK DETAIL SCALE: NTS 1-1/2" x 1-1/2" x I8 GA. HAT \,L,/SCALE: NTS CHANNEL MAC GIRT SPACED 42' O.C. \-2x3 RAFTER --SHAT CHANNEL TO RAFTER DETAIL SCALE: NTS FACTORY DIRECT METAL Date: APR 08, 2008 r ..c �i�ca �= STEEL STORAGE SHED SCALE: AS SHOWN CONNECTION DETAILS 9 2414 N. 1325 E. P: 801.768.0361 LEHI,UT84043 F: 801.768.0362 ROSS MCGOWEN` Of 10 BUILDING DIVISION APPRO,/M ANTI—SIPHON BIDE LAP METAL DECKING PROFILE (ROOF) 29 GA. PRO -RIB Ix=O.130, Sx=0.0205, Fy= 80 ksi SCALE:NTS #12 x 1" SELF DRILLING SCREW 2"X2" SQUARE TUBING USED IN MOST JOINING APPLICATIONS 14 GA, Ix = 0.3482, Sx = 0.3482, Fy = 50 ksi SCALE:NTS SCHEDULE METAL DECKING 29 Go. PRORIS (WALLS) 29 Go. PRORIB (ROOF) Fy = 80 ksi Fy = 80 ksi 2"x2" SQUARE TUBING 14 Go. Fy = 50 ksi 2"x3" RECT. TUBING 14 Go. Fy = 50 ksi BOTTOM CHORD CONNECTION DETAIL SCALE:NTS 2"X3" SQUARE TUBING 14 GA, Ix = 0.7894, Sx = 0.7894, Fy = 50 ksi FACTORY DIRECT METAL Date:APR 08, 2008 "132E STEEL STORAGE SHED SCALE: AS SHOWN MISC. INFORMATION 10 01.768.0361 01.768.0362 ROSS MCGOWEN Ilk 1� of 10 DuII&�-- 3UILDING DIVISION APPROVED w Structural Calculations for Factory Direct Metal 5625 Eastside Road Redding CA, 96001 Ross McGowan 95 Gipson Rd. Bangor, CA 95914 24'x 20'x 9'-0" Steel Building (5'-0" O.C. Frame Spacing) Prepared By: Mitch Mortensen, P.E. BUTTE COUNTY BUILDING DIVISION APPROVED . IMA N. 132lsa 5 E. LehiUT 84043 izWML8-0362-� 68-0361 6 TABLE OF CONTENTS SECTION and DESCRIPTION PAGE NO. 1.0 Design Criteria Name: Ross McGowan # 07-028 igner MCM 1.1 Design Codes and References ______________________ 1.2 Design Loads ______________________________ 1.3 Design Materials and Stresses ____________________ 2.0 General Notes 2.1 Concrete Specifications ______________________________ 2.2 Concrete Reinforcing Specification ______________________________ 2.3 Soil Specifications ______________________________ 2.4 Steel Specifications ______________________________ 3.0 Structural System -------------------- —________ 3.1 Roof System ______________________________ 3.2 Wall System .............................. 3.3 Floor System ______________________________ 3.4 Foundation System ______________________________ 4.0 Design Parameters ______________________________ 5.0 Structural Loads 5.1 Vertical Loads 5.2 Lateral Loads 5.3 Load Combinations ______________________________ 6.0 Structural Analysis ------------- __-___-____ 6.1 Wind Forces 6.2 Seismic Forces 6.3 Roof Diaphragm Design ______________________________ 6.4 End wall / Shear wall Design ______________________________ 6.5 Holdown & Anchorage ______________________________ 7.0 Structural Sketches 8.0 Product Data PAGE NO 4 4 4 4 5 5 5 6 6 6 6 6 6 6 7 8 8 9 10 11 11 12 12 13 14 33 34 D 2414 N. 1325 E. Job Name: Ross McGowan Lehi, UT 84043 Job # 07-028 TAU= P:801-768-0361 Designer MCM 1.0 DESIGN CRITERIA: 1.1 DESIGN CODES & REFERENCES • 2007 Edition of the California Building Code • 2006 Edition of the International Building Code • ASCE 7-05 • Steel: Allowable Stress Design, Ninth Ed. (AISC) • Concrete: Reinforced Concrete Design Handbook (ACI) • Ultimate Strength Design Handbook (ACI) 1.2 DESIGN LOADS Dead Load: Structure Weight Live Load: CBC Sec. 1607 Wind Load (3 -sec): 85 Wind Exposure: C Site Class: D Roof Snow Load: 20 1.3 DESIGN MATERIALS & STRESSES mph psf (minimum roof LL = 20 psf) Steel Tubing Manufactured per ASTM -A500 Carbon Steel 16-22 Gauge — cold rolled steel Hot Dipped Galvanized Bolts Machine Bolts: Reinforcing Steel Grade 40: Grade 60: Concrete Normal Weight 16-7 Gauge — hot rolled steel ASTM A-123 and ASTM A-153 Anchor Bolts: ASTM A-36 or better ASTM A-307 or better ASTM A -615-76A #4 Bars and smaller Fy = 40,000 psi #5 Bars and larger Fy = 60,000 psi F'c = 2500 psi in 28 days Soil Foundations have been proportioned based on an allowable soil bearing value of 1000 psf (with 1/3 increased for seismic) in accordance with 2007 CBC. BUTTE COUNTY BUILDING DIVISION APPROVED . 2414 N. 1325 E. Joh Name: Ross McGowan Lehi, UT 84043 Job # 07-028 P:801-768-0361 Designer MCM 2.0 GENERAL NOTES: 2.1 CONCRETE SPECIFICATIONS 1 All concrete shall be normal weight and attain a minimum compressive strength of 2500 psi in 28 days. All concrete edges, corners, and intersections shall be tooled or chamfered 1" whether or not shown on the drawings. 2 The maximum concrete slump shall be: Slabs 3" + or — 1" All other work 4" + or — 1" 3 The minimum cement content shall be 5'/Z sacks per cu. yard and shall be a standard brand type II, low alkali, per ASTM C-150. 4 Any water reducing agents added shall be used to reduce the water/cement ratio. 5 Aggregate shall conform to ASTM C-33. Maximum aggregate size shall be 1" U.N.O. Use %" aggregate for slabs on grade. 6 Anchor bolts to be full diameter, cut thread made from ASTM A-36 steel by an American manufacturer and installed per "Lateral. Requirements" on the following pages. 7 Curing: Freshly deposited concrete shall be protected from premature drying and excessively hot or cold temperatures, and shall be maintained with minimal moisture loss at a relatively constant temperature for the period of time necessary for the hydration of the cement (typically 7 days). 8 Special Inspection is NOT required for the footing concrete. 2.2 CONCRETE REINFORCING SPECIFICATIONS All reinforcing steel shall be continuous. Splices in reinforcement shall NOT be made at or near points of maximum stress. Splices shall be lapped not less than 30 bar diameters and in no case less than 24". Reinforcing bars shall have minimum bend radius of 6 times the bar diameter. Bars shall not be heated to facilitate bending. Once bent, steel shall not be straightened. 2 Reinforcing bars to be deformed bars conforming to ASTM A-615 76A. #3 & #4 Grade 40 #5 & larger Grade 60 All reinforcing steel shall be accurately positioned and adequately tied using proper chairs and bolsters. Nails in wall or stem wall forms will not be acceptable. Supports and chairs placed against exposed surfaces shall be galvanized or provided with plastic feet. 4 Concrete cover over reinforcing is required as follows: Willa -E COUNTY ULDING DIVISION APPROV&D 3". ------- concrete is exposed to and cast against earth 2" --------- concrete is exposed to earth but cast against formwork 1 '/2" -------- concrete is not exposed to earth or weather 2.3 SOIL SPECIFICATIONS Minimum required soil bearing (DL + LL) to be 1000 psf. Expansive index (assumed' / from report) *verification may be required by building official It is recommended that on building sites exhibiting characteristics of instability, a soils investigation be performed (unless waved by the local building review agency). Any deviation from the design values shall be brought to the engineers' attention. 4 All required fill and backfill shall be compacted to at least 90% of maximum density unless otherwise noted on a soils report. 2.4 STEEL SPECIFICATIONS All structural steel plates, bars, angles and channels shall conform to ASTM A36 Standards. 2 All steel tube products shall be manufactured per ASTM -A500 Grade A - 1008 and 1010 Carbon Steel Grade B - 1010 thru 1022 Carbon Steel / 15 gauge and heavier , Grade C —1015 thru 1022 Carbon Steel / 15 gauge and heavier 3 Carbon Steel used shall conform to the following: 16 gauge — 22 gauge (cold rolled steel) 16 gauge — 7 gauge (hot rolled steel) 4 Wall thickness: Cold rolled tubing (see table 9 of ASTM A-513) Hot rolled tubing (see table 6 of ASTM A-513) 5 Bending Radius: (Minimum workable) 2 % to 3 times the outside diameter (round) 3'h to 5 times the outside dimension (shapes) 3.0 STRUCTURAL SYSTEM: 3.1 ROOF SYSTEM Steel decking over steel tube standard truss Diaphragm will be considered flexible for calculation purposes. 3.2 WALL SYSTEM Ordinary moment resisting frame, horizontal metal decking. 3.3 FLOOR SYSTEM No Floor 3.4 FOUNDATION SYSTEM ITW Redhead wedge anchor BUTTE COUNTY BUILDING DIVISION APPRO»FD 2414 N. 1325 E. Job Name: Ross McGowan W Lehi, UT 84043 Job # 07-028 .> P:801-768-0361 Designer MCM F:801 -768-0362a e 4/9/2008 -4.0 Design Criteria: Building Dimensions Width 24 ft Length 20 ft Eave Height 9 ft Frame Spacing 5 ft Post l Number of Posts in Transverse Direction Number of Posts in Longitudinal Direction Elbow Connection Brace Horizontal Length Brace Vertical Length Soil Type: Foundation Type: Slab Thickness Concrete Density Footing Width Footing Depth Anchor Type Roof Sheathing Roof Sheathing Gauge Roof Purlin Spacing Wall Sheathing Wall Sheathing Gauge Roof Rise 3 Roof Run 12 Peak Ht. 12 ft 2 6 18 in 18 in Soft Slab on Grade 4 in 144 pc. 12 in 12 in RedHeadWedge 29 GA 5 ft o.c. 29 GA U COUNTY 3UIL®ING 01VI A PPE3011 �I� ,n 'Company Designer Apr 9 2008 Job Number: 4:10 Om Checked By: Bask Load Cases Joint Boundary Conditions Joint I nhal Hot Rolled Steel Design Parameters Label Shang I angthr I h—W&I I k ;-r"I I Ma L%,UIIIj2 IUJ2.. LCUMP DOI_ K-OUJ K -in GM I I s ...Ins way Fund- 7.51 M1 1 1Lateral 3 M3 3x2xl4Ga 1.546 Lateral 5 M5 2x3xl4Ga 10.823 R IS J Lateral � SRIW, 613 2.625 7 M7 2x2x14Ga Lateral WN 9 M9A 3x2x 4 a.5 I Lateral ma AM BE Aff 11 M11 2x2x14Ga 2.401 Lateral WRIM-112MAK-0 W W, —XIN WK ME 13 M13 I 2x2x14Ga , 10. 5 Lateral QW. Wt.a.n AU ON I Member Distributed Loads (BLC 1 Hot Rolled Steel Properties Member Section Forces (By Combination) RISA -2D Version 8.0.2 ... \Projects\07-028 - Factory Direct Metal\Enginee T-'rds'2d] — '— — — - 6 UIR -fa I UIL DIV19 APPROVED N1- - IH- T LU-Inj Reaction Reaction Rotationfk-.. 11-A 3 N5 5 N12 Hot Rolled Steel Design Parameters Label Shang I angthr I h—W&I I k ;-r"I I Ma L%,UIIIj2 IUJ2.. LCUMP DOI_ K-OUJ K -in GM I I s ...Ins way Fund- 7.51 M1 1 1Lateral 3 M3 3x2xl4Ga 1.546 Lateral 5 M5 2x3xl4Ga 10.823 R IS J Lateral � SRIW, 613 2.625 7 M7 2x2x14Ga Lateral WN 9 M9A 3x2x 4 a.5 I Lateral ma AM BE Aff 11 M11 2x2x14Ga 2.401 Lateral WRIM-112MAK-0 W W, —XIN WK ME 13 M13 I 2x2x14Ga , 10. 5 Lateral QW. Wt.a.n AU ON I Member Distributed Loads (BLC 1 Hot Rolled Steel Properties Member Section Forces (By Combination) RISA -2D Version 8.0.2 ... \Projects\07-028 - Factory Direct Metal\Enginee T-'rds'2d] — '— — — - 6 UIR -fa I UIL DIV19 APPROVED Company Designer Apr9 2008 Job Number: 4:10 OM Checked By: Member Section Forces (BV Combination)fContinued) LC &Aa -K., I �kpl - Version 8.0.2 ... \Projects\07-028 -Factory tory Direct Metal\EngineeriggLTu9,'P"4.13,L)UN;i6e 2 BUILDING DIVI&ON APPROVED Axia, S nmpn NE 1 M Rtrk-ft] MSI 07 v S N 7 2 -10 .4SUM .-.323 1.256 1.183 E - �ffil - -"aWgl UI 0 X..... R10 . I . . . . . . . 712- 1 W L_ 9 -.323 1 256 .241 HIN -0- NO -51: 5 _w-- WE, 12 W 11 1 M3 -1 -1.297-.23 13 3 -1.32 -102 -.188 149.`' -,,F BEER, wmg, mw Map,. �. �. 15 MEN 5 -1.344 6 -.073 11=_1 17 2 2.382.014 -.009 m wou 19. 4 .014 026 21 1 M5 1 3.629 .484 -.107 23 N.3 STAN,', al 3.465 -.952 ME WIN _5 1- ..,. I , W I 25 5 3.301 -.828 1.754 I l�lm TMI %-I,- f w ®R W 27 2 -3.183 .003 022 12 ISMY EANNE IN 08-01 M 29 -3.183 .003 .007 WE in �Fglvl all 31 1 M7 .003 0 0 61 awl Ui IM ME � � I � K. - W 33 .003 0 .4 47 i2rd0 0. 35 5 .003 0 0 NOWW l:�w l�gvLv 37 2 1.546 .221 -.413 `4yMWAI WIN OZYWRMWMW�` WTH 39 . . . . . . .. . . . 4 1.546 1 -1.24 14' US i FAV MR. 41 1 M9A 1 .323 -1.256 -1.654 kSUM wV0., 43 'N -1.256 -.712 r - 45 -.323 -1 256 'T - -- .2- '3 P S2PR ` '1 IN� llf 4 47 -1 30 .218, Wall 49 -1332 .149 •.139' 51. 1 M11 1 2.382 -.01Np 4 0 . . . . . . . . . . WWI fABERNOW MOM 53 3 2.382 -.014 .0,0 WON p- .017 --- E , i - �TEMSIEPWIA 55 . . . . . . . .5 2.382 -.U14 034 . Z Wo 57 3.547-.156 .974 59 4 3.383 .5 .043 61 3 183 --03 10152-64,003 Version 8.0.2 ... \Projects\07-028 -Factory tory Direct Metal\EngineeriggLTu9,'P"4.13,L)UN;i6e 2 BUILDING DIVI&ON APPROVED ,, 'Company Designer 4P 0 OM 08 Job Number: Checked By: Member Section Forces (By Combination) (Continued) MA.ld K 63 3 3 183 zsnear K Mo nt kftl - 003 - 015 aii�;�4k;. � �r" ���' �' r b '""fir ,^51 ar k; `yt��. F.ts {.., �r A v°, +�. -- , , i . . r s .��� '. 2 t ` I '� ' 65 5 183 03 0 �t,a.. �..:hi1'MJWill, 2 003.. 0 - 0 67iag r �0� r xr� 69*� M 4 I 69, TEN 1, U z; 0 2 4 142063 216 216 Member Section Stresses (By Combination) 1 1 M1tAxialIKS1B di B Bendngrksil w 2 1 .492 2t 3 3 2 134 492 16 044 16.044 5. 5 2 134 - 49232 088 32 088 . � �_;� ��.;� �,. $w,.,,� �..� � ..:445: ;,��.,2 03'�"�`� ��� 74 2 445 2.803 -22.948 r k a,s7rry �,u yr �, A 22 948 �J ,rt�m .4.4.6 2803' }r �, 3 ` 13,8 ml. I : 9� 4 445 2.803 4 669 4.669 1. � t,"'���� NOR,, .,: � �.�u�. � ����� ��`.�,5'� k��:.:� '1�44�5�` 11 1 . M 3 5 ,. 1-1.79 4471 -4.471 .....MIN§ZIA3"'':... 13 3 -1.822 3.644 3.644 14 " 4 � `1 8 '8r �" 83"32 2f,:03' Y ��� MWONAIM 15 i16X 1? ` .` 5 1.854 -.437 1.41 �M9i '���4� 42��c . 41 17 2 4 142063 216 216 19 4 4 142 063649 649 a a5 �.,:. 6.3. ` s_+ 86:5.'. sC �'8 , . • - , ..h 21 4 M5 1 5.008 1.081 2.074 -2.074 �,"Y'S' r•.r• , M. ... .. .� . �.; ` ., 4`89'"x`.. 3 l.. ,. 24'41 w.d r .' 1 RAN 23 3 4.781 384 18.477 18.477 24 .:. fi� .. „ .'� ��', a 4 '.11116 u>;" yA2/55 4.555 1.848 -34.021 34.021 'X#L:VA.. �1 rt, ."cx`x4..��^ 4 af'°�,�+'Y3" � 14.1 c 3 „ '� `c w•V'� `�t.� k'i- 3� 'p §`' 'i r rc. r 27 2 -5.535 013-568 69s, 29 4 5 535 4 �< 013 ' 3 x ,, . s LO, W . a� � _5 � �5 5.3"5? `' �,01�3 OWN. O31 1 X32 33 M7 1 005 0 0 w : 4 'Company Apr9 2008 Designer Job Number: 4:10 OM Checked By: Member Section Stresses (By Combination) (Continued) RA --k-. I -k-1 i uL) oenui QJKSI J bot tsenamll(Sll OWN, V101,01 ACTAN7 Ul—VINN 47 2 -1.806 .123 -4.233 4.233 X-4814" Eir I .6f 49 &,,AmA�g 4 -1.838 .332 -2.703 2.703 sigg'.4 1. R -,"A W =K 0198, v N M 54TMER, 51 1 Mil 1 4.142 Hamm LOW—A i l, =. , , ... :Yti21'6OO21YfiN53 3 4.142432 - 063 =1 42% "w, RE1094 55 5 4.142 -.063 -.�M Ufa 865 5 91004 57 2 4.894 -.349 -18.888 18.888 0, UT -f'R,7%;4VW 2-50, 4� 3 W..7107WO 9 59 —.%. 4 4.668 1.116 -.841 1 .8 60` WO, Ulhal I 4 A NOW WON, 0 61 1 ,2 M13 1 -5.535 .013 -.758 .758 EM vlila an rNWEt 63 3 -5.535 -.013 .379 -.379 g 7 65 113112 5 -5.535 -.013 0 0 ug �Wd g �gvyp EAW "M OW 67 2 .005 0, 0 0 me tin� �m 69 4 .005 0 0 0 EWTE: COUNTY dUILDING DIVISION APPROVED RISA -2D Version 8.0.2 ... \,...\Projects\07-028 - Factory Direct Metal\Engineering\Truss24.r2d] Page 4 2414 N. 1325 E Lehi, UT 84043 .., P:801-768-0361 F:801-768-0362 6.1 Wind. Based on ASCE 7-05 Method 1 Design Criteria Design Information: Roof Pitch Vertical 3 Length of Analyzed Section Horizontal 12 Width of Analyzed Section: 0: (degrees) 14.03 Roof Eave Height Exposure C Roof Peak Height Wind 3 Sec. Gust Speed: 85 Roof mean Height a 2a not less than 3) Eoh -28.4 Joh Name Job # Designer A 17.424 E wrrc= 63.5 plf B -7.056 F wrreb= 127 lb C 14.112 G wrre= 597.5 lb D -3.969 H Wind Loads: -20.28 -13.23 -14.112I Roof Dead loac Roof Live Load -10.143 Ross McGowan 07-028 MCM 1 Story L= 25 ft W= 24 ft H= 9 ft hp= 3 ft h= 10.5 ft a= 2.5 ft 2a= ' 6 ft DL= 5 psf LL= 20 psf hp wrrd wrre wrr 2a H/2 wrrc wrr L 2a W wrre Transverse (Perpendicular to ridge) Roof Wind Pressure (D): Wall Wind Pressure (C): Diaphragm Load (C+D) End Roof Load (B*2a*hp): End Wall Load (A*2a*H/2): End Wall Load (A+B): Diaphragm Shear Load .16 hp wrgc JH/2 Longitudinal (Perpendicular to Gable) wrrd= 11.91 plf wrrc= 63.5 plf wrr= 75.41 plf wrreb= 127 lb wrrea= 470.4 lb wrre= 597.5 lb Vwr- 1070 Ib wrge R2a 1WArgC W 2a wrge Wall Wind Load (C): wrgc= 84.67 plf Additional Wind Pressure (A): wrge= 17.42 psf End Wall Load (B*2a): wrre= 27 Ib Diaphragm Shear Load 1043 Ib BUTTE COUNTY 3UIL®ING DIVISION APPROVE® ross mcgowan Date and Time: 4/9/2008 4:06:41 PM Seismic Design Category - Conterminous 48 States Latitude= 41.0757, Longitude= -124.15109 MCE MAP VALUES Short Period Map Value - Ss = 255.5% g 1.0 sec Period Map Value - S1 = 118.5% g RESIDENTIAL DESIGN INFORMATION Short Period Map Value - Ss = 255.5% g Soil Factor for Site Class D - Fa = 1.00 Residential Site Value = 2/3 x Fa x Ss = 170.3% g Residential Seismic Design Category = E allILDING DIVISION APPROVED - - . 2414 N. 1325 E. ' Job Name: Ross McGowan Lehi, UT 84043' Job # 07-028 w . P:801-768-0361 Designer MCM 4/9/2008 Continued - Lateral Analysis 2006 CBC 1 Story 6.2 Seismic: Based on ASCE 7-05 Eq. Lateral Force Procedure Design Criteria Length of Analyzed Section: L= 25 ft Roof Live Load LL= 20 psf Width of Analyzed Section: W= 24 ft (20% LL if over 30) LL20= 0 psf Roof Eave Height H= 9 ft Roof Weight Wr- 3000 Ib Roof Dead load DL= 5 psf Site Class D Sds: (2/3*Fa*Ss) 1.7 Fa: 1 Shc:(2/3*Fv*S1) 1.19 Fv: 1.5 Resp. mod factor Trans Rt= 3.5 Ss: 2.55 Resp. mod factor Long RI= 2 S1: 1.19 Importance factor 1= 1 Seismic Response co. Tran (Sds/R/1) Cs= 0.486 Seismic Response co. Lon Sds/R/1) Cs= 0.85 Seismic Loads: hp Vwt H/2 L Vwt= 80.14 plf W Transverse (Perpendicular to ridge): Roof Diaphragm Weight: Wd= 3000 lb Wall Weight (both sides): Ww= 1125 Ib Seismic Base Shear: Vbr= 2004 Ib Maximum Diaphragm Shear: Vrmax= 1002 lb Jhp Vwt H/2 W Vwt= 82.57 plf L Roof Diaphragm Weight: Wd= 3000 Ib Longitudinal (Parallel with ridge): Wall Weight (both sides): Ww= 1080 lb Seismic Base Shear: Vbp= 1982 lb Maximum Diaphragm Shear: V max= 990.9 Ib BUTTE COUNTY BUILDING DIVISION Ei. a BUTTE COUNTY BUILDING DIVISIOK APPROVED Apr 9, 2008 at 4:11 PM Lateral Analysis Truss24.r2d 'Company Apr9 2008 Designer 4:11 OM Job Number: Checked By: Basic Load Cases Joint Boundary Conditions W -t I ahol Y L11; Hot Rolled Steel Design Parameters Label — Shape Len th I-b-OLffift] Lb -in I -comp top.. I -comp bot., K -out Clb 0 Is ... In s v Functi.. M1 3x2x14Ga 7.5 Lateral MONM 3 M3 3x2x14Ga .1 .546 M mo Lateral 114 5 M5 2x3x14Ga 10.823 Lateral 7 M7 2x2xl4Ga 2.625 FOUR MIEMMRIP Lateral 9 M9A 3x2x14Ga 1.5 Lateral 11 M11 I 2x2x14Ga 2.401 Lateral 13 M13 2x2x14Ga 10.5 Lateral ....... . . . . . . Member Distributed Loads Hot Rolled Steel Properties Member Section Forces (Bv Combination) LC memhor Lahal L UJ 11.6011.1 --Rotation[k- Footing Ni Reaction— Reaction fflawamm Ego, 7 4 W - NEW .21 001.1 WON N �10� 3 N5 K--nRM -r t, gg u,! % 5 N12 Hot Rolled Steel Design Parameters Label — Shape Len th I-b-OLffift] Lb -in I -comp top.. I -comp bot., K -out Clb 0 Is ... In s v Functi.. M1 3x2x14Ga 7.5 Lateral MONM 3 M3 3x2x14Ga .1 .546 M mo Lateral 114 5 M5 2x3x14Ga 10.823 Lateral 7 M7 2x2xl4Ga 2.625 FOUR MIEMMRIP Lateral 9 M9A 3x2x14Ga 1.5 Lateral 11 M11 I 2x2x14Ga 2.401 Lateral 13 M13 2x2x14Ga 10.5 Lateral ....... . . . . . . Member Distributed Loads Hot Rolled Steel Properties Member Section Forces (Bv Combination) LC memhor Lahal RISA -2D Version 8.0.2 ... \Projects\07-028 - Factory Direct Metal\—Engineerir�g��fLv'u" s,24:7r2b.IVVI` &gg 5 BUILDING DIVISION APPROVED M1 ShearlKi -.107 Momentlk-ftl 0 .146 3 SAW 3 -.107 .146 -.548 INNEMPS 5 5 Op. -.107 1 .146 -1.097 N Ral Ag 7 8 NO S -1 WN WI WIN 2 1.14 3 1 -.965 11001110- AN i R71.1 Ej RISA -2D Version 8.0.2 ... \Projects\07-028 - Factory Direct Metal\—Engineerir�g��fLv'u" s,24:7r2b.IVVI` &gg 5 BUILDING DIVISION APPROVED 'Company Designer AApr 2 pr 9 2008 Job Number: 4:1Checked By: c Member Section Forces (By Combination) (Continued) - 9 - __ --- OIJUdFlrIMO a -T( 4 1.143 965 -.012 X10 ska � � ..:� 11 1 M3 1 1.489 805 35 1?2. '"°``.. ah8.iV1" 2�48:9x . tr.8.05'z'„c:�0.3" 13 3 1.489 805 - 272 �14YMaf:"�� R s, ���'��Y.�80:5:��� �:x�,��.` `.,. a �.•y,58Y4�.� 15 5 1.489 805 895 pz11'>607 "W1M ,tom; , F r 17 016. ..,... 2 y -1.67' 087 0 2 ,i . Z.3�� 19 > �� , ,� , 4 -1.67 - .156 20 � � b ,4 r{.. z �? 5 ` �� 1 67 <t ',`r � p Q8r?¢�.' �x MASUD IMRI `x 21 1 M5 1 073 126 -1.104 MMM . s, .� ';,, f 2�`073su yeas P126i� wr nNrhi� r 's. 233 2 .. .073 6 sit.. �r'�.�MEMO 073=`i i2 , - 4 25 5 073 126 2fi 258 t 7. 27 2 .037 002 02 M M 9MPI N01 ..Iti4 MEw�"? r �3��� �� .� '.037°� ��i"� �������rOv02��� � ; �t' !�w' l �'t'; - 7� x �,0.1,3 294 Vis: � _ 037 ; ., :G I :> r 5 537��� 0�2, �%Nwi l��%. 0,-10.���.-II 31 1 M7 1 0 039 0 , Q w >, . ; '4.. t52 "' a ,'.0"`'9a 33 39 052 35 5 0 MEMKINNIME 39�"'_37, t0 2107 YF* 1) 139 r d /x 26 �am,�1x07� aa��✓.='y�� �., �+�' war ����>n,�� �a r� 2..����w.s!t�'t 39 ..��.:'�1y39 4 7 139 781 1 rr 41 1 M9A 1 1 83 41 °`YJ MOM ��J }ip� x MON-10 s 928 F S 9 � ,L .�,.�W�YJ rRiSAS,F; � . 5 ". r � Y� } t T i� 4 �i t- {aAa, ...' . fi a ., it'',� 43 3 1:083 345. ` 44 ��: ' '"`x � 4 � 1 Or8.3� _ .: 5"28 ? + y 10•. :his _. 45 1 5 .083 5 928 3 1 47' `' 2 1.163 826 032 `48 '.". �'3�1?63k. s ..82 is r2Y8}7 494 50 ... 1.163 _ . �r'"5-11i63'� ' M$26 ts.'t v, -.606 `t>a 51 1 M11 9 09 0 2>:: M. �s r �� . few Y.. �z1 2 �� � � ':.OYg;< ��T-19012, r - 53 3 1 1.596 09 108 WT641, 1Mp4 X1596 ,x �..w':0:9Ys ' -16f1 55 5 1.596 09 215 4-vil �x 1141 57 >1 2 091 131 737 F �M1 A, 5$t . w s' , _ .'°": €, • z 3 Ky ,s x.,..0:91 '�� s ' < ',X1.3 s zx ;� ���009il" 59 . 4 091131 y .08 x1,3,1-,0!h�2:Zt3`�34 61 1 M13 1 259 002 024 2: RL MWE `. 63 3 .259 002 t 0450 .012 ri 4r.. `�?'f 1 P �''$'�f ) c{g ,t • N' -Y C'"Y, t 50 65 5 .259 -.002 0 RISA -2D Version 8.0.2 [\..:\...\...\Projects\07-028 - Factory Direct Metal\Engineering\Tru s27r:2dj �? 6 SUILDING �tiV I SI� *Company Apr9 2008 Designer 4:11 OM Job Number: Checked By: Member Section Forces (By Combination) (Continued) LC Member Label Sec Axial[kl Shearfkl Momept[k-ftl IWO. M -s NI -0111 N ''' _ 'Flo '44 67 U N; I -I PR 1p 4% 2 0 61 .36 IN, 69 4 '0 .017 0Z OR =001. W T, Member Section Stresses (By Combination) LC KAPMhor I ahol ....... M114 -ShearlKSII - lQpljendingfkQ- NO .7 .326 0 7119�0 3 . 3 -.147.326 RalrybMan 515 1931T Rim 10.639 -10.639 5 14-11NM11-5va-83saw - 5 -.147 .326 21.277 -21.277 NO 7 2 1.577 -2.152 14.259 -14,249 W -RE - 7 2 " 0 * -M, - - ON 96omw Is o, NNOW ANN, 9 4 1.577 -2.152, .29A -.224 1, W. NOWNW-; ' 11 1 M3 1 .2 .055 1.797 -6.794 6.794 MWN fimmm ER".2 3 3 2.055 1.797 .286 -5.286 14 3," _�vw �, M 15 5 2.055 1.797 7.367 -17.367 M W YOU 17 2 -2.904 .386 1 318 -1-318 St 194 .386 3.954 -3.954 21 1 11 M5 1 01 .281 21.4 1 12m2l.412 s. A ln28x1MOO". 23 -.281, .199' -8.199 25 5OPEWMAIN MORTAIATEMI.- .101 -.281 11 -5.014 5.014 A 'RAN, MMON I'll 27 lw�- WON .065- -.011 .493 .493 EWEN 29 M LIM. X., -WW�PMw, I �wl' RZO 4' �Wlml 0 4 1 �Wfll 51651-11.11 .065 -.011 qq�.164 -.164 WON NO 0 REIMERS MINN. --ly M7 1 0 -.175 0 0 33 3 0 -.175, -1.308 t308 71374-0 'r -1,0M ON E NNi"NAKI rRINUNWER 35 5 0 -.175 -2.617 2.617 37 2 .147 .31 5.048 -5.048 39 4 .147 31 15.145 - 5.145 w � a N- - 1 ~11' A -�Jw�mry �41 1 M9A -1.495 -2.071 20.194 -20.194 43 1 �l 10, . ........ 3 A.495 -2.071 6.689 -6.689 X MWE IN - I - �Wl WIN, 45 5 -1.495 -2.071 .-6.815 6.815 IE 7 TWN - I W � WON 60.5 47 1 1 Al 1 2 -1.605 1.813 -.622 .622 "P41 " M OmMON61 RISA -2D . Version 8.0.2 ... \Projects\07-028 Factory Direct Meta'I\Eng'95'99FL-Is�;2k4;r?JNTYPage 7 3UILDING IONISION, APPROVED 'Company Apr9 2008 Designer 4:11 OM Job Number: Checked By: Member Section Stresses (By Combination) (Continued) ---1 --0.1 _. I oR penaingiK$ii - bot benChn-lksil 49 4 -1.605 1.843 11.765 -11.765 BEA R M 2 A Q T-0 7959 51 1 Mil 1 2.775.398 0 0 I ENRON' 53 3 2.775 .398 2.719 -2.719 RM, W4 WeRi I ON-= aml, ISM % 55 1 - 5 2.775 . 98 5.439 -5.439 ?"T!5-95 VASIN"iff VKHRIN M WIN rp 57 t X12'6 2 .126 .291 15.275 -15.275 59 4 .126 -.291 1.56 6 ME SARIN;, 9 )OINRAI-Ar 1411MO, � � 19 61 1 M13 1 .451 -.01 .619 -.619 NA, 63 3 .451 .309 .-.309 REM 65 1 .451 -.01 0 0 1 W16000"ASWIM MINIMUM 1 0, rl RMUNC3 67 20 1U61 9103 9.103 69 1.161 .439 .439 M NOR"` NOR HIM TIRE 'N -ft ---, I'l,".X.lolololololololda"�MI-114E.4-r-r-r-r-r-r-r-r-rl"w I b MR. 6 1 W-1 OR?, . . . . . . . . . . . . XON N-R."=M607 BU-ffE COUNTY '3UlLDI.Nr--F- DIVISIM RISA -2D Version 8.0.2 ... \Projects\07-028 - Factory Direct Metal\Engineering\Truss24.r2d] Page 8 ' RED HEAD® y AMORING SYSTEMS Submittal Information Ultimate Tension and Shear Vahrip c n hc/&Ail ;me ANCHOR DIA. In. (mm) INSTALLATION TORQUE Ft lbs. (Nm) EMBEDMENT DEPTH In. (mm) ANCHOR TYPE ft= 2000 PSI (13.8 MPa) Fir =4000PSI (27.6MPa) Pc= 6000 PSI (41.4 MPa) TENSION Lbs. (kN) SHEAR lbs. (kN) TENSION lbs. (kN) SHEAR Lbs. (kN) TENSION Lbs. (kN) SHEAR Lbs. (kN) 1/4 (6.4) 8 (10.8) 1.1/8 (28.6) 1-15/16 (49.1) 2-1/8 (54.0) WS -Carbon or WS -G Hot -Dipped Galvanized °f WW3045.5. or SWW-3165.5. .. ... 1,180 (5.2) 2,100 (9.3) 2,260 (10.1) 1,400 (6.2) 1,680 (7.5) 1,680 (7.5) 1,780 (7.9) 3,300 (14.7) 3,300 (14.7) 1,400 (6.2) 1,680 (7.5) 1,680 (1.5) 1,900 (8.5) 3,300 (14.1) 3,300 (14.7) 1,400 (6.1) 1,680 (7.5) 1,680 (7.5) 3/8 (9.5) 25 (33.9) 1.112 (38.1) 3 (76.2) 4 (101.6) --1,680-(7.5) 3,480 (15.5) 4,800 (21.4) 2,320 (10.3) 4,000 (17.8) 4,000 (17.8) 2,24_0( 10.0) 5,940 (26.4) 5,940 (26.4) 2,620 (11.7) 4,140 (18.4) 4,140 (18.4) 2,840 (12.6) 6,120 (21.2) 6,120 (27.2) 3,160 (14.1) 4,500 (10.0) 4,500 (20.0) 1/2 (12.7) 55 (74.6) 2-1/4 (57.2) 4-1/8 (104.8) 6 (152.4) 4,660 (10.7) 4,660 (20.7) 5.340 (23.8) 4,760 (21.21 7,240 (32.2) 7,240 (321) 5,100 (22.7) 9,640 (42.9) 9,640 (42.9) 4,760 (21.1) 7,240 (32.2) 7,240 (32.2) 7,040 (31.3) 10,810 (48.1) 10,820 (48.1) 7,040 (31.3) 8,160 (36.3) 8,160 (36.3) 5/8 (15.9) 90 (121.0) 2-3/4 (69.9) 5.1/8 (130.2) 7-1R (190.5) 6,580 (29.3) 6,580 (29.3) 7,060 (31.4) 7,120 (31.1) 9,600 (41.7) 9,600 (42.7) 7,180 (31.9) 14,910 (66.4) 15,020 (66.8) 1,120 (31.1) 11,900 (52.9) 11,900 (52.9) 9,720 (43.2) 16,380 (72.9) 16,380 (72.9) 9,616 (42.8) 12,510 (55.1) 12,520 (55.7) 3/4 (19.1) 175 (237.3) 3-1/4 (82.6) 6-5/8 (168.3) 10 (254.0) 7,120 (31.7) 10,980 (48.8) 10,980 (48.8) 10,110 (45.0) 10,320 (90.4) 20,320 (90.4) 10,840 (48.2) 11,700 (78.7) 17,880 (79.5) 13,720 (61.0) 23,740 (105.6) 23,140 (105.6) 13,300 (59.2) 20,160 (90.1) 23,580 (104.9) 15,980 (71.1) 23,740 (105.6) 23,740 (105.6) 1/8 (22.2) 250 (339.0) 3.3/4 (95.3) 6-1/4 (158.8) 8 (203.2) 9,510 (42.3) 14,660 (651) 14,660 (65.2) 13,160 (58.5) 20,880 (92.9) 10,880 (92.9) 14,740 (65.6) 20,940 (93.1) 20,940 (93.1) 16,580 (13.8) 28,800 (128.1) 28,800 (118.1) 17,420 (77.5) 24,360 (108.4) 24,360 (108.4) 19,160 (85.2) 28,800 (128.1) 28,800 (128.1) 1 (25.4) • en.,.,.tine,,,i.a.A•.._...____.._.._•__.•____......_...., 300 (406.7) 4-1R (114.3) 7-3/8 (187.3) 9-1/2 (241.3) 13,940 (62.0) 14,600 (64.9) 18,700 (83.2) 1 16,080 (71.5) 18,680 (121.6) 28,680 (127.6) 10,180 (89.8) 23,980 (106.7) 26,540 (118.1) 1 22,820 (101.5) 37,940 (168.8) 37,940 (168.8) 1 21,180 (94.2) 33,260 (148.0) 33,260 (148.0) 24,480 (108.9) 38,080 (169.4) 38,080 (169.4) • For Tie -Wire Wedge Anchor, TW-140Quse tension data from l/4- diameter with t-1/8"embedment. For continuous ettreme low temperature applications, use stainless steel. • Allowable values am based upon a4toIsafety factor. Divide by4for allowable load values 3. UILDING ®MSM /TWRed Head` 8ro7 7-800-899-7890 38 www.itwredhead.com IMT711 Ultimate Tension and Shear Values (Lbs/kN) in - a 'Ur4frelim Lightweight Concrete* 7ANCHORINSTALLATION EMBEDMENT ANCHOR LIGHTWEIGHT CONCRETE LOWERFLUTEOFSTEELDECKWITH TORQUE DEPTH TYPE Yc = 3000 PSI (20.7 MPa) LIGHTWEIGHT CONCRETE FILL Ft lbs. (Nm) In. (mm) Yc = 3000 PSI (20.7 MPa) TENSION SHEAR TENSION SHEAR Lbs. (kN) lbs. RN) lbs. (kN) Lbs. (kN) 3/8 (9S) 2S (33.9) 1-1/1 (38.1) WS -Carbon or 1,110 (9.4) 3,720 (16.5) 1,900 (8.5) 3,160 (14.1) 3 (76.2) WS -G Hot -Dipped 1,940 (13.1) 4,240 (18.9) 2,840 (12.6) 4,000 (17.8) 1/2 (12.1) 55 (14.6) 2-1/4 (57.2) 3.600 (16.0) 7,040 (31.3) 3,400 (15.1) 5,380 (23.9) 3 (76.2) Galvanized 4,720 (21.0) 6,620 (29.4) 4,480 (19.9) 6,620 (29.4) 4 (101.6) or WW -304 S.S. ..... -•--- 6,920 (30.8) 4,800 (11.4) 6,440 (28.6) 5/8 (15.9) 90 (122.0) 3 (76.2) 6,000 (26.7) 9,240 (41.1) 4,720 (21.0) 5,500 (24.5) S (127.0) or SWW3165.5. 5,960 (26.5) 9,280 (41.3) 6,580 (29.3) 9,140 (40.1) 3/4 (19.1) 175 (237.3) 3-1/4 (82.6) 7,160 (31.9) 12,600 (56.0) 5,840 (26.0) 8,880 (39.5) S-1/4 (133.4) 8900 (39.6) 15,920 (70.8) 7,040 (31.3) ----- -- • Allowable values am based upon a4toIsafety factor. Divide by4for allowable load values 3. UILDING ®MSM /TWRed Head` 8ro7 7-800-899-7890 38 www.itwredhead.com BRED HEAD® l Information, itt Subma ANCHOR/NO SYSTEMS MIN. ALLOWABLE SPACING BETWEEN ANCHORS In. (mm) LOAD FACTOR APPLIED=.40 2 (50.8) 1.15/16 149.21 (133.4) .. Recommended Spacing and Edge Distance 152.4 1.15/16 Requirements for Shear Loads* ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE MIN.EDGE MIN. EDGE DISTANCE SPACING DIA. DEPTH TYPE REQUIREDTO DISTANCEATWHICH AT WHICH THE REQUIREDTO In. (mm) In. (mm) 5 OBTAIN MAX. THE LOAD FACTOR LOAD FACTOR OBTAIN MAX. 95.3 3 76.2 WORKING LOAD APPLIED =.60 APPLIED =.20 WORKING LOAD 2-1/4 (57.2) 3.15/16 (100.0) 1-9/16 (65.1) In. (mm) In. (mm) In. (mm) In. (mm) 1/4 (6.4) 1-1/8 (28.6) 5-3/16 2 (50.8) 1-5/16 (33.3) 79.4 3-15/16 (100.0) MIN. ALLOWABLE SPACING BETWEEN ANCHORS In. (mm) LOAD FACTOR APPLIED=.40 2 (50.8) 1.15/16 149.21 (133.4) 1.15/16 49.2 152.4 1.15/16 49.2 1(25.4) 3.15/16 (100.0) 157.2) 3.1/8 3/8 (9S) 1.1/2 (38.1) WS -Carbon 2-5/8 (66.7) 1-3/4 (44.5) 5.11/16 (144.5) 5-1/4 5 3 76.2 or WS.G 3-3/4 95.3 3 76.2 1.1/2 (38.1) 6 1/2 (11.1) 2-1/4 (57.2) 3.15/16 (100.0) 1-9/16 (65.1) - 7-7/8 (100.0) 4-1/8 104.8) Hot -Dipped Galvanized 5-3/16 131.8 3.1/8 79.4 1-9/16 39.7 6-3/16 5/8 (15.9) 2-3/4 (69.9) 4-13/16 (112.2) 3.1/8 (79.4) 2-1/8 9-5/8 S-1/8 130.2 or WW -304 S.S. 6.7/16 163.5 3-7/8 (98.4) 1-15/16 (49.2) 7-11/16 3/4 (19.1) 3-1/4 (82.6) 5.11/16 (144.5) 3.3/4 (95.3) 1-3/86 11-3/8 (76.2) 6.5/8 1683 or 6-5/16 (160.3 5 127.0) 2-1/2 (63.5 4 7/8 (22.1) 3-3/4 (95.3) 6-9/16 (166.1) 4-5/16 (109.5) 38.1 13-1/8 151.4) 6-1/4 158.8) SWW-316S.S. 8-1R (215.9) 6.1/4 (158.8) 3-1/8 (79.4) 12-1/2 1 (25.4) 4-1/4 (108.0) 7.7/8 (200.0) 5-1/8 (130.2) 1.9/16 15-3/4 6-3/16 1-3/8 181.3 (79.4) 10-1/16 (255.6) 1 7.3/8 187.3 3.11/16 (93.7) 14-3/4 Spacing and edge distances shall be divided by 0.75 when anchors are placed in structural lightweight concrete. Linear interpolation maybe used for Intermediate spacing and edge distances. MIN. ALLOWABLE SPACING BETWEEN ANCHORS In. (mm) LOAD FACTOR APPLIED=.40 2 (50.8) 1.15/16 149.21 (133.4) 2.5/8 (66.7) 152.4 3 76.2 (200.0) 3.15/16 (100.0) 157.2) 3.1/8 79.4 (144.5) 4.13/16 (122.2) (195.3) 3-7/8 (98.4 (288.9) 5.11/16 (144.5) 252.4) 5 121.0 (333.4) 6-9/16 (166.7) (317.5) 6.1/4 (158.8 (400.1) 7.7/8 (200.0) Recommended Spacing and Edge Distance Requirements for Tension Loads* ANCHOR EMBEDMENT ANCHOR EDGE DISTANCE MIN.ALLOWABLE SPACING REQUIRED MIN. ALLOWABLE DIA. In. (mm) DEPTH In. (mm) TYPE REQUIREDTO OBTAIN MAX. EDGE DISTANCE AT WHICH THE LOAD TO OBTAIN MAX. WORKING LOAD SPACINGATWHICH THE LOAD FACTOR WORKING LOAD FACTOR APPLIED=.65 In. (mm) APPLIED= .70 In. (mm) In. (mm) In. (mm) 1/4 (6.4) 1.1/8 (28.6) 2 (50.8) 1 (25.4) 3-15/16 (100.0) 1 (50.8) 1.15/16 (49.2) 1-15/16 (49.2) 1 (25.4) 3-7/8 (98.4) 1-15/16 (49.2) 2-1/8 54.0 1.5/8 41.3 13/16 (20.6) 3.3/16 81.0 1.5/8 41.3 3/8 (9S) 1.1/2 (38.1) 2-5/8 (66.1) 1-5/16 (33.3) 5-1/4 (133.4) 2-5/8 (66.7) 3 (76.2) 3 (76.2) 1.112 (38.1) 6 (152.4) 3 (76.2) 4 101.6) 3 76.2) 1-1/2 38.1 6 151.4) 3 6.2 iR (12.7) 2-1/4 (57.2) 3-15/16 (100.0) 1 (50.8) 7-7/8 (200.0) 3.15/16 (100.0) 4-1/8 (104.8) WS -Carbon or 3-1/8 (79.4) 1.9/16 (39.7) 6-3/16 (157.2) 3.1/8 (79.4) 6 152.4 WS -G Hot -Dipped 4.1/2 (114.3) 2-1/4 57.2 9 128.6 4.1/2 114.3 5/8 (15.9) 2-3/4 (69.9) 4-13/16 (112.2) 2-7/16 (61.9) 9-5/8 (244.5) 4-13/16 (122.2) 5-1/8 (130.2) Galvanized 3-7/8 (98.4) 1-15/16 (49.2) 7.1/16 (195.3) 3.7/8 (98.4) 7-1/2 190.5 or WW3045.5. 5.5/8 142.9) 2-13/16 71.4) 11-1/4 (285.8) 5.5/8 142.9 3/4 (19.1) 3-1/4 (81.6) 5.11/16 (144.5) 1-7/8 (13.0) 11-3/8 (288.9) 5.11/16 (144.5) 6-5/8 (168.3) 5 (127.0) 2-1/2 (63.S) 9.15/16 (252.4) 5 (117.0) 10 254.0 or SWW-3165.5. 7-1/2 190.5 3-3/4 (95.3) 15 381.0) 7.1/2 190.5 7/8 (22.1) 3.3/4 (95.3) 6.9/16 (166.7) 3-5/16 (84.1) 13-1/8 (333.4) 6-9/16 (166.7) 6.1/4 (158.8) 6.1/4 (158.8) 3-1/8 (79.4) 12-1/2 (317.5) 6.1/4 (158.8) 8 203.2 6 (152.4) 3 76.2 12 304.8 6 152.4 1 (25.4) 4-1/2 (114.3) 7.7/8 (200.0) 3-15/16 (100.0) 15-3/4 (400.1) 7-7/8 (200.0) 7-3/8 (187.3) 7-3/8 (187.3) 3.11/16 (93.7) 14-3/4 (374.7) 7.3/8 (187.3) 9-1/2 (2413) 7.1/8 (181.0) 3-9/16 90.5) 14-1/4 (361.0) 7.1/8 (181.0) 1-1/4 (31.8) 5-1/2 (139.1) 9-5/8 (244.5) 4-13/16 (122.2) 19-1/4 (489.0) 9.5/8 (244.5) 8 203.1 8 (203.2) 4 101.6 16 406.4 8 203.2 -----------._.---'-----+-.._...._.._....._._.._....,............. y,,,...,y­ .—-nnr,yuwuuo„wru<aoroI.+nnrrnrcmarr�pdangdna cage amances. Combined Shear and Tension loading -for Trubolt Anchors Allowable loads for anchors subjected to combined shear and tension forces are determined by the following equation: (P8/P00+ MNOO st Ps = Applied tension load Vs = Applied shear load Pt = Allowable tension load Vt =Allowable shear load BUTTE COUNTY 3UILDINC DIVISM APPROVED /T( W Neil' 8/07 7-800-899-7890 39 www.itwredhead.com RESIDENTIAL- 2(g-- - - 028-24440 PERMIT#94-3019,,. MCGOWAN, ROSS W.- 95 GIPSON'S RD., BANGOR REPAIR & REMODEL STG ROOM/SF t3 4 k OFFICE COPY Addres '�. Date E G N Opp ✓; Address ICE COPY GAS Meter E3 ter B RIC Date EY JOB FINALED (Date) ^ a• '- — Signature J=OK O = Not OK Not = , Not Ready MOBILE MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. / /"Nat. or/ /" L"ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card -B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card ,B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS. <• Date DECKS, COVERS, CARPORTS, GARAGES, (Pla;:rs)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK O = Not OK Not Readt, RESIDENTIAL (Single Date UN 00 dans) OK except ti's Zo -Setbacks Easements -Flood -Slope Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftq. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wra pped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except ti's 16. Water Htr.: Vent -Access -Combustion Air -Baffle 17. Water Pipe: Test & Anchor -Nail Protection 18. D.W.V.: Test -Fittings & Anchor -Nail Protection ------------------- -------------------- 19. Shower Pan: Test. First Floor -Tub Access --------- ------------------------------ 20. Test Tub.& Shower. - Second Floor -Tub Access ------ ----------------------- -------------------- ---21. Gas Pipe: Size & Anchors ---------------------------------------------------------------------------- Date - Card B_1-- Date - Card B-1 -------- ------------------ ---------- Date Card B-1 Date Card B-1 Date i5�kRICAL (Permit) OK except ti's �Fixt re & Transformer Clearance -Ins. Protect on le Receptacles Spacing -Light sat Doors _ ze Boxes & No. of Conducto d mex Installed Close to Edge of Studs & C.J. -- -------------- ------------ --- -- -/q ----------------- ------------------------ --------------- 36' E � Ground made up wrMech. Fastners-Bond Gas & Water ------ ---- Appliance Circuts-in Kitchen &-Conductor SizerGFI - - -_ 28. Subfeed Wire Size ga. Cu or AI-A.C. Wire Size / ga. Cu or At ---------------------------------------------------------------------------------- 29. Range Circ / / ga Cu or At -Oven Circ. / ! ga. Cu or Al. nsulated Neutral ❑ Yes ❑ No -- - ---- Service -Riser Conductors & Ground -Main Disconnect - - -------- - -------------------------------- Equip_Clearances Panels_Motors-Mech. Equip. ------------------------------------- 32. Clothes Closet Light -Shower Light -Spa Light .-____.____.__L____ mci Detector ---------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 - ------------------ --- Date -Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except ti's 34. A.C. Ducts Insulation & Support ---------------------------------------------------------------------------------- 35. Vent Fan; Exhaust above insulation ----------------------------------------------------- - --------- 36. Condensate Drain & Overflow: Size & Grade ----------------------------------------------------- - - 37. Furnance-Vent: Access -Comb. Air -Return Air Vent -115 outlet -- - - -------- --- ---------- ------------------------------ 38 Attic Access & Platform if Furnance in Attic ----------------------------------------- -------------------------- - ----------- Date Card B-1 Date Card B-1 ------------------- - ------------- ------------------------------ ---------- Date Card B-1 Date Card B-1 Date FRAMI Plans) OK except ti's „Sits per Material .&-Anchors 4 all tuds-Nailing. Spacing -&-B racing -Plates -Sound- -------------- -------------------------------------------------- ---- 4 e g W_a is over Girders & Floor Nailing ------------------------------------------------------ 4_ r top in Walls (rat proof) - -- 4�Fi: Furred Ceilings -Stairs -Chases -Tub ___________4 Beam -Size &Bearing - & Duplex) Date MING (Continued) 4� H ers-Post Caps -Anchors -Connectors -- - 4 „C9' Ing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. -- --__ Ties or Type A Flue -Fireplace Throat clearance 4" ttic A cess; Size & Romex Protection -Draft Stop -Ins. Baffles drm. Windows or Exiting Doors -Sill Hgt. & Dimensions re Protection Framing :-------- _ Pro y Line Firewall & Openings _ xt. Doors -One 3' -Check Garage -3rd Story, 2 Exits --------------------- ----------- -_ Ja3_Sta4+,3--Width-Head room -Rise -Run- Land ing-Fire Protection -_____-_--56' don Roof Overhang Attic Vents Rafter Outriggers _ Siding -Nailing Veneer ---------- -_ o Mesh -Drip Screed -Fd. Vents-Underflr. Access _ Glazing Area -Glass Protection -Skylights -Plastic -- -- a alls: Nailing -Bolts Insulation -Walls -Ceilings U11 II - e; L -9-30 60. Infiltration -Walls -Windows It Date Card B-1 _ _ Date _ Card B-1 Date Card B-1 Date Card B-1 Date F N Plans) OK except ti's Ex eps-Door &Sidelight Protection -Landings CaPI-Smoke Detector ----------- ---------------- Furnace; Vents -Clearance -Comb. Air -Connector - In arage; Above Floor -Ducts -Meeh. Protection -------------------------- edroom Exiting Wier ll. & Bath Fixtures & Tub Access -Spa ---------------- --- . i- p 6 c. --rim- T&Sub anel; Breaker Sizes & Labels ------------------- ------------- 67-StaTrS' !- Is - - 68. Fireplace or Stove: Clearances -Hearth ll/, 6AI!e . Outlets at -Wood -Panel: Int. & Ext. 7 F I. & Appliance; Grnd.-Air Gap -Cooking Clearance --- 7 ec. Outlets & Receptacles at Kit. Counter ---- -------------- --- 7 Ga*are-Beate SwingLanding-Close r 9Closer 78"�-A'"-�6-4-)uct-rn Garage -Damper 7t� r. Htr Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection --------- --- ------------- 7 - Ib.. Elec. & Mech. Equip. Listed for Location ------------ 7-.------ _ es in Garage: (G.F.I.)-Romex Protection anon -Foam -Looked in Attic Yes Guard Rails & Deck Construction -Post Caps 7�� n. Vents & Crawl Hole Door -Drainage &W -Earth Clearance Looked under Floor Yes 80. Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes C1- No ----------------------------------- 84_-4Stjeeo-Bmw n -Finish --------------- --- - onnect. Electrical, Plumbing /its Above Roof; Plbg.-Appliance-Fireplace.-Clearance to Openings -----------34--Wat------ :Disconnect, Electrical, Plumbing -- Well: Disconnect, - -- rior Elec. Trim; G.F.I. Receptacle -Underground -------------------------- - ---- ntilation Throughout House .- ------ ----------- --------- lass Protection - ..... - -- .. -- _. ------------------------------- orrections. from Previous Inspections ...... . -- . - . - ---------------- ---------------------- FbYt;as t -Meters Tagged: Gas -Electric ate, & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates ------ -------------------- -- ------------------- Date iCj�/ Card B-1 Date _ Card B-1 Date , Card_B-1-Date Card B-1 DateV Card B-1 Date Card B-1 Comments a Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California. 95865 - Telephone (916) 538-7541, PERMIT NO. APPLICATION 'AND PERMIT ®I ASSESSOR PARCEL NUMBER CJ— 028--23Q ZONING 5 BUILDING PERMIT OWNER ROSS W. MCGOWAN TELE oNE 991-9068 SO. FT. OCC. BUILDING VALUAT OWNER'S MAILING ADDRESS 7040 W. 2ND RIO LINDA, CA -95673 20 @ 60 1200.00 288 M 5,182.00 CONTRACTOR'S NAME TELEPHONE OWNER EST 8,000.00 CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ 14 382.00 LENDER'S MAILING ADDRESS Filing Fee $ 20,00 Permit Fee $ 105.30 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 68 4 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS, Q PERMIT FEE $ 193.75 BANCOR, CA 95914 PLUMBING PERMIT Filing Fee 20.00 Each Trap7,00 Solar or heat pump water heater 23.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP Water piping 15,00 Each gas water heater or vent 15.00 USE OF STRUCTURE SFIi Duplex O Mobilehome O Other SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G I W @20.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation 1:1Other ❑ Describework: REROOF, REPAIR DRY ROT, UPGRADE SERVICE PERMIT FEE $ Contractor ELECTRICAL PERMIT Filing Fee 20.00 & REIPIRE DOORS & WINDOWS/SIDING 600V OR LESS Main service ( 00AORLESS 1 23.00 Iii SULATIONONEW Main Service ( 200A TO 1000A ) 46.00 R C NS.T ( D SEACCC OCC PLOSU I 3.50 F0 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one) ❑ 1 am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect.FIXED License No. Classification I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) O I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) O I am exempt under Sec. Business and Professions Code forthis reason NEW CONST. MULTI -OUTLET -NON-RESIO. ( BRANCH CIRCUITS I @7.50 ( POWER APPARATUS ) 8 SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 @ 1.00 BAL. @ .50 APPLNS. OR EX. Occup. (OUTLETS IRESID.) EA. 1 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. I I shall not employ any person in any manner so as to become subject to the Worker's (` Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 85 .00 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Contractor I certify that I have read this application and state that the above information is correct. 1 agree to comply to all Butte County Ord' 19nces and California State Laws relating to building construction, and h eby auth i representatives of the County of Butte to enter upon the ab n . ned pro r for inspection purposes.�"�Sf��rY� I also agree t v nify an eep harmless the County of Butte against all liabilit' s, ' me and 'p as which may in any way accrue against said Coun i nsequen f a I of this permit. X Date `�' 3 "� % LL Signature of Applicant Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ f V �1/,27Q.75 TOTAL FEE HAZ- 1 D. FEES I IMPFLDO cD PARCEL PD HD SSU This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. �y'G BYlhw)���_ Date 7 PERMIT EXPIRES ON 4d9 (Dere Receipt No. 1 689(44 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES ;. 1469 Humboldt Road, Chico,;CA 891-2751 s1;> 7 County Center Drive, Oroville;,CA - (91'6) 538-7541 . 747 Elliott Road, Paradise, CA - (916) 872-6307 a CORRECTION NOTICE C r-1? 7) W 0 :3U/9 x OWNER PERMIT NO. tl A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact tAis office immediately. t � a ou; ex 60 Date �— /r " g �� Inspector k(a,56 e (� , REV 10/92 COUNTY OF'BUTTE BUILDING DIVISION r DEPARTMENT OF DEVELOPMENT SERVICES %fk 1469 Humboldt Road, Chico, CA -'(916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) .872-6307 CORRECTION NOTICE OWNER PER IT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. a 4 `d�Inspect - Date 4 . REV 10/92 ''ti Insulation Certificate BUILDING OWNER. V S f) 4 AJ BUILDING PERMIT # s- q V',� 0 I q Description of Installation j ROOF F Material 3rand Name Thickness (inches) '(hermal Resistance (R -Value) CEILING Batt or+Blanket Type f� " 13rand Name Thickness (inches) Thermal Resistance (R -Value) O. Loose Fill Type B and Name - Contractor's minimum installed weight/ lb Minimum thickness 16 - inches Manufacturer's installed weight per square foto to acheive'llbermal Resistance (R -Value) EXTERIOR WALL Material lam- w✓ , 1, . Name — Thickness (inches) 3 ;t7 Thermal Resistance (R -Value) % 5 RAISED FLOOR 1 Material (Mand Name Thickness (inches) Thermal Resistance (R -Value) f SLAB FLOOR Material Thickness (inches) Width (inches) FOUNDATION WALL Material Thickness (inches) Declaration .f, E, rand Name Thermal Resistance (R -Value) Brand Name Thermal Resistance (R -Value) I hereby certify that the above insulation was installed in tt;.e building at the above location'in conformance with the current Building Energy Efficiency Standards for new residential buildings contained in Title 24 of the California Administrative CodW.1 / actor (Builder) license Number t� ,1 2a)A Date Sub -Contractor (Insulation Installer) Liceue Number Signature and Title Date THIS CERTIFICATE MUST .BE PROVIDED TO THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE POSTED WITIIIN THE BUILDING. JANUARY =993 COUNTY OF BUTTE -DEPARTMENT OF DE. EL �PMENTSERVICES - BUILDING DIVISION It 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER ! c ,/GG" / - A No. 1 -,? -- Proposed Building UsetT48LVE _Affib hI.IT) IY' Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: J 01 DATE RECEIVED BY I1 1l . . 1, All items have been submitted. .......................... 2. Plot plans, 3/4 sets, signed by preparer:of plans. .' ......................... 3. Complete plans, 3/4 sets, signed by pre -parer of plans........ . 4. Engineered plans and calcs, 3/4 sets„with wet signature on plans. ............. 5. Hazardous Material Form . ............................................ 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . I 9. Mobilehome data and manufactureft'installation instructions, 2 -sets. ........... ` 1 �. Fees of $:.• ... l .................:-.., ................. mpact fees as shown on attached schedule. .. 71..........::-'' 12. California Department of Forestry plan approval ees ..07 > ...... . I' -- - 3 Flood elevation letter (100 year flood b Californla`Engineer.................. . 14. Sanitation and plot plan approval '_Health Department . ............ 15. City of Chico plumbing permit. ........................................ . 11_ 16. Plot plan and business license approval from City of Biggs/Gridley. ............ . "`- 17! Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval required prior to occupancy). ... Pre -Inspection request 20. Pre -inspection for required. .. to Building Inspector. (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner . .......... . 24. Recorded copy of Agricultural Acknowledgement Statement . .................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . ......................... '................. 28. Mobilehome utility clearance . .......................................... -i 29. Documentation of legal access . ...... ...............:.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed f and (B) Parcel meets zoning area and frontage requirements. ............... 31. Existing violations/expired permits . ...................................... 32. Plan check list . ..................................................... 33. 34. When you issue the permit, process as follows: ail to owner. - ztWY to con/Actor. Telephone and hold for pickup at ice. Deliver with inspector. Other Parcel Creation Acreage Applicant Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By �r ,The following data must be submitted prior to permit issuance: (Circle new item not checked above). % 1. Index permit for above items No. / 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone mail'' Counter by _ Date Plans checked by Date Plans approved by -C Date ZELP� C Sets of plans on hold in File cabinet AP folder Copy ! Department of Public Works �°IN. 1 TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Yf E.H. USE ONLY,, Plat Plan Auachad Floor Plan Atlachad Scat to B.D. ) ) - T / 4 c Liu l,✓ �° , Qty N Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for bedroom mobile home. Others �•�AD, Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist Date R/Q1 N COUNTY OF BUTTE Department of Development Services Building Division Oroville: 7 County Center Dr., Oroville CA 95965 Ph: 916-538-7541 Chico: 1469 Humboldt Rd., Chico CA 95928 Ph: 916-891-2751 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) 2. I (have/have /not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: Address Phone City Contractor's License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work:* Name Address City, Phone Contractor's License No. 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: Property Owner Z JRA✓ /� Social Security Number :;—a 7 — O Date // — 3— Vi q NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. I 1 1 r" ALL STRUCTURES AND EQUIPMENT INCLUDINr2 OVERHANGS SHALL. BE CLEAR OFA ALL EASEMENTES. b A SET SACK OF �V FT. FROM 'THE SIDE AND 4 ' 3 d 1=T. FROM � rIE REAR PROPERTY LiN' ES AND . T. FROM THE ROAD CENTER ..iNE SHALL. BE CLEAR OF STPUC`a TIRES ANDEQUiP��fE�3�' EXCEa�- T FOR A 2 FT. SAVE 9VERHAIgaC . REVIEWED BY : BU17E CO. FIRE DEPT. CALIF. DEPT, of FORESTRY ` ❑ approved as submitted ap fen, with a. ons 'per atlacheed sl Bets Sig (� c \\ N 3� 1 IVA ?7 #� Of, •fir• f , S• Z CDF—FIRE SAFE REQUI. Ri NTS -?z � - oZ 3o19 fy1 � �ow.f0' /kms AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. [�l 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. rivewav Standards [J 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other appirtezant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [ ] 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [ ] 2. The length of ver':i=.�l curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [ ] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [ ] 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [ ] 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of : 2. , .24-2-3 - o z q -el, /�-i 5aa/ 4J4 /�oss AP # PERMIT # NAME [ ] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [ ] 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 .feet of the building. 1273.11 Gates [ ] 1. Gate entrances shall be at least two feet wider than the roadway it serves. [ ] 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. [�] 1. All parcels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. [x] 1276.02 Disposal of vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction :,r fi�ral inspection of a building permit. Page 2 of 3 AP # PERMIT # NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [ j If Building Setback is Less Than 15 Feet Choose any 3 of the following:. - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed 10% of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3 91 i...... ..... Q\ A86 SEAM_ 1�I■I i...... ..... Q\ A86 ^r`�y.R�L�i ♦ .q - . _ • ' '*� r - On Z tiY� J�,s. . i'��.e�.'°y�i�,b'tg`Jr'�,,q w • . fy.C"�t u�i�w � � w����,.. � •u.° "�, _C{�w�..•�Y s}.� �,�s�.�..r :.aia.::. 24 FI _ ' �' 9 ra`'t-. tK'`•e[�',n n.:�..x...,v- ' `'' r�C�►s•/%Ai�.,iar�i���!►:3j+. » � wrw..� .-� .. .. - .. .. N j � -tn A � kµ1 E•-+'�i .�+.h.Jewt�..�i'..t•v�n.� � •p ._. ...: � � ��- .. • .... :. _ . .`ice . _ N -i 46 a • 'sem, � .. 7 APPROVE[ Butte County Environmental Health -- Dae ------ ------ --------- Signature----- r 7 APPROVE[ Butte County Environmental Health -- Dae ------ ------ --------- Signature----- 028-210-018 PERMIT#95-2726 ,. McGOWAN, Ross W. 95 Gipson's Rd., Bangor g 1st Rentwal BP#94-3019 �q-�1� Fcy: c�-iii%CI'`'1✓r�•t,,.tr++P'v:,,$ynP� '•V x:y,`N�- .-t$91ti3s�t.�.;}G.c�J`r,.... ;i+h*9yd;ra5ils^y�wri��"'.'+' • '` ` COUNTY OF'BUTTE-.DEPARTMENT OF DAVELOPMENTSERVICES - BUILDING DIVISION/ 7 County Center Drive - Oroville, Californja� 95965 - Telephone (916) 538-754 PERMIT NO. APPLICATION AND°PERMIT ASSESSOR PARCEL NUMBER 028-240-018 tJ ZONING A5 BUILDING RMIT OWNER .' i ,, ., ROS W. 1,�WWAN,. TEUPHONE 99l -0Q6 SO. FTI%, OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 7040 W. 2ND' RTO LINDA, 95673 , CONTRACTOR'S NAME.pp , OWER TELEPHONE - CONTRACTORS MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNIQJOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 20.00 Permit Fee 105.307-2 ARCHITECT OR ENGINEER 1` LICENSE NO. Plan Checking- Fee $ Energy Plan Checking Fee $ ARCHiTECr OR ENGINEERS MAILING ADDRESS Penalty 9$ BUILDING ADDRESS .. OIPSON°S Rff- !%' PERMITFEE, __ ERMITTEEs" 72 2:..79ti0095 a, • •. f :- '' IN,*-`'7 i�:iw•..a.. PLUMBINGPERMIT ,;.T&•c�Tr:9p, , .• -S . Filing Fe0e 2, 0.00 LOT NO. 4 S UBDNIS IONS NAME ' 3 PARCEL MAP- Solar or heat pump water heater '23.00 ` USE OF STRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping15.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 �t TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: — RI?NWA,i.' OF #94--3019 Mobile Home IS I GI W1 920.00 PERMITTEE g Contractor ELECTRICAL PERMIT Filina Fee 20:00 000V OR LESS ` Main Service ( 200A OR LESS ) 23.00 j . Main Service ( 200A TO 1000A ) 46.00 • LICENSED CONTRACTOR'S -DECLARATION I herebyaffirm under' anal of er ur that I am licensed under r rovison's of'Ch er 9 (comencing with Section 7000f of Division.3 6(the Busin1ess'and' Professions Code, and my license is in full force/and effect. 1' 1 / ,� , � e, a License Class Lic. No. t r , I / ar ' OWNER -BUILDER DECLARATION "7 ..i 1 hereby affirm under penalty of perjury that I amJexemptJrUn the Contractors License Law for the following reason: 7 41. /"' ,e 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors „ to construct the project. I ❑ I am exempt under Sec , t Business and Professions. Code, for..,this) �'�reasori •~t''`�1 1 t T'" � � r` NEW CONST. DWELLING OCCUR OR ( 8 ACC. ) SO. 3.51L FT. CNS. NEW CONST. MULTI-OUUTLETLE T � NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS ) a SINGLE OUTLET CIR. ''OEx. Occup. ( OUTLET OR FIXTURES ) 20 Q 1.00 BAL 50 EX{pOCCU FIXED APPWS. OR ?• ( OUTLETS (RESID.) EA) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE g + Y antracto •- - • ;'-4 p'•• r , '-:` # �...,,�,,. - - WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: ` Carrier MECHANICAL PERMIT Filing Fee 20.00 9 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number (The above sections need not be completed if the permit is for work of a'valuation of one hundred dollars ($100) or less.) ❑ I certify that in the performance of the work for which this permit is issued, I shall not employ any—person in any • manner so as to become subject to Workers' compensati rr (aw�o f Californiafl agree that f I should become subject :to the workers' eomgensfftion provisions of section 3700 of the Labor Code, Ishall fohhwith`comply with those p o`visions. X ate �"�"—��----- ---- Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ E Dec CONST. TYPE TOTAL FEET 72,90 HAZ. D. FEES IMP FLOOD CDF PARCEL PD HD SSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. � 1 ? B. .F Date �jS�1/��� 1 r PERMITEXPIREON i # • (Date) Receipt No. !{�, WHITE-D.D.S.-B CANARY-AS_.SE SSOR PINK -INSPECTOR GOLDENROD -APPLICANT Jr COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES- BUILDING DIVISIO 7 County Center Drive - Oroville, Cgrfornia ;95965 - Telephone (916) 538-754 PERMIT NO. APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER i}.a• 028-240-018 ZONING A5 BUILDING P RMIT OWNER ROSS W. MCGOWAN T 91N9068 SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS 7040 W. 2ND RIO LINDA, 95673 CONTRACTOR'S NAME - OWNER TELEPHONE CONTRACTORS MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNIWOWN Total Valuation Is LENDER'S MAILING ADDRESS Filing Fee $ 20,00 Permit Fee 105.30/2 $ 52.90 ARCHITECT OR ENGINEER F. LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ' ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS 95 GIPSON ' S RD PERMITFEE $ 72.90 BANGOR CA 95914 PLUMBING PERMIT , Filing Fee 20.00 Each Trap . 7.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP Solar Or heat pump water heater 23.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: RENEIJAL OF #94-3019 Mobile Home ]TFdr W @20.00 PERMITFEE S Contractor ELECTRICAL PERMIT Filina Fee 2 0:0 0 -•+ - - Main Service(600 OR LESS zooA OR LESS ) 23.00 Main Service ( 200A TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affi m under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCURSO. OR ( 8 ACC. BUDS. ) 3.5¢ Fr. CNS. NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS ) 8 SINGLE OUTLET CIR. Ex. Occup. (OUTLET OR FIXTURES) BAL Q +•50 L SO EX. Occup. ouriFrs RESID.) EA ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ Contractor WORKERS' COMPENSATION DECLARATION I hereby affir under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of.the work for which this permit is issued, I shall not employ an rson in any anner so as to become subject to workers'L compensate aw f Californi nd agree that if I should become subject to the workers ion prove ' ns of section 3700 of the Labor Code, I shall I m ith those p isions. /' X a'! -s ate _�Q �/Z Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE I TOTAL FEE $ 72.90 HA2. D. FEES IMP FLOOD CDF PARCEL PO HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicateq above for which fees ave been paid. B Date PERMITEXPIRESON 1/9/96 (Date) Receipt No. ;Ls WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT Attention Property'Owner:` - An `.`owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your, earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement : YES[A NO[ ]. 2. I HAVE" HAVE NOT[ ] signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide'some of the work but I have contracted (hired) the following persons to provide'the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: PROPERTY OWNER: SOCIAL SECURITY NUMBER: DATE: NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. * - This verification must be completed and returned to our office before we are permitted to issue the permit. OVER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property improvements specified For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: 0 If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. 0 There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "ownerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. , Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not to issued until the verification is returned. 16 Sinccrel r. / 1 r Micha4l C. Vieira, C.B.O. Manager, Building Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. OVER