Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
028-260-012
I ft. 0 r r ,28-26-Y2 HILDA TAYLOR, E/S Laporte Rd, app 550' N of - Oro Bangor Hwy, Bangor.'" Permit ##888-78E (ele ser SF i 028-260-012. 2-16 INALED BARTH, TERESA 5726 LAPORTE RD., BANGOR CONT: EXECUTIVE HOMESI no NEW MH PERM FND EX SITE pla �n I J I 'P NOTES I RESIDENTIAL 028-260-012 2-1680 ERMIT NO, BARTH, TERESA 5726 LAPORTE RD., BANGOR CONT: EXECUTIVE HOMES NEW MH PERM FND EX SITE w THE HCI) FORM 433A FOR THIS MH CANNOT BE j RECORDED UNTIL ONE OF THE FOLLOWING HAS BEEN TURNED IN TO THE BUILDING DIVISION: - (1) LICENSE PLATE(S) OR DECAL (THE I INSPECTOR MUST RETREIVE). (2) STATEMENT OF FACTS (ONLY ON NEW MH' S). INSPECTOR TO VERIFY SERIAL & LABEL #'S. I I w SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS II VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER OFFICE COPY Address GAS Z Meter By Date ELECTRIC Meter By (� Datdj_?�lz__ JOB FINALED (Date) " ` 1/ °, Signature 925���� COUNTY OF BUTTE BUILDING DIVISION - DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. vC.) tt9c cam c'sf f ! S rrlr-o , cf-- f /-f )-).) D?-ETJ- � . REV 10/92 FLEETWOOD HOMES OF CALIFORNIA, INC. 18 N. PIONEER AVE.. PO BOX 1308 WOODLAND, CA. 95776 MC# 17 Date of Manufacture HUD label No.(s) PFS738411 ' C� PFS738412 Manufacturer's Serial Number(s) and Model Unit Designation WOODLAND PARK 4483) CAFL117A25268-WP12 CAFL117B25268-WP12 Design Approval by (D.A.P.I.A.) PFS CORP. This manufactured home is designed to comply with the federal manufactured home constructionand safety standards In force at time of manufacture. (For additional information, consult owner's manual.) The factory installed equipment includes: Equipment Manufacturer Model Designation For Heating NORDYNE M1MH056 For Cooking WHIRLPOOL SF315P Refrigerator WHIRLPOOL ET8CH Water Heater RHEEM 21I40T Smoke Detector RIDDH 1275E HOME CONSTRUCTED FOR X ZONE I ZONE II ZONE III EXP. "D" This home has not been designed for the higher wind pressure and anchoring provisions required for ocean/coastal areas and should not be located within 1500' of the coastline in Wind Zones II and III, unless the home and its anchoring and foundation system have been designed for the increased requirements specified for Exposure D in ANSI/ASCE 7 - 88. This home has ( ) has not (X) been equipped with storm shutters or other protective coverings for windows and exterior door openings. For homes designed to be located in Wind Zones II and III, which have not been provided with shutters or equivalent covering devices, it is strongly recommended that the home be made ready to be equipped with these devices in accordance with the method recommended in manufacturers printed instructions. Design roof load zone map: _ North 40 psf X South 20 psf X Middle 30 psf Other psf i COMFORT HEATING This manufactured home has been thermally insulated to conform with the requirements of the federal manufactured home construction and safety standards for all locations within Uc value Zone 1,2 . (See map at bottom) Heating equipment manufacturer and model (See list at left). The listed heating equipment has the capacity to maintain an average 70 degrees Fahrenheit temperature in this home at outdoor temperatures of — 7 0 degrees Fahrenheit To maximize furnace operating economy, and to conserve energy, it is recommended that this home be installed where the outdoor winter design temperature (97 %%) is not higher than —28 degrees Fahrenheit. The above information has been calculated assuming a maximum wind velocity of 15 mph at standard atmospheric pressure. COMFORT COOLING F]Air conditioner provided at factory (Alternate 1) Air conditioner manufacturer and model (see list at left). Certified capacity B.T.UJhour in accordance with the appropriate air conditioning and refrigeration institute standards. The central air conditioning system provided in this home has been sized assuring an orientation of the front (hitch end) of the home facing . On this basis the system is designed to Maintain an indoor temperature of 75°F when outdoor temperatures are °F dry bulb and °F wet bulb. The temperature to which this home can be cooled will change depending upon the amount of exposure of the windows of this home to the sun's radiant heat. Therefore, the home's heal gains will vary dependent upon its orientation to the sun and any permanent shading provided. Information concerning the calculation of cooling loads at various locations, window exposures and shadings are provided in Chapter 22 of the 1989 edition of the ASHRAE Handbook of Fundamentals. Information necessary to calculate cooling loads at various locations and orientations is provided in the special comfort cooling information provided with this home. X I Air conditioner not provided at factory (Alternate II) The air distribution system of this home is suitable for the installation of central air conditioning. The supply air distribution system installed in this home is sized for a manufactured home central air conditioning system of up to 6 3 , 5 0 0 B.T.U. /hr. rated capacity which are certified in accordance with the appropriate air conditioning and refrigeration institute standards, when the air circulators of such air conditioners are rated at 0.3 inch water column static pressure or greater for the cooling air delivered to the manufactured home supply air duct system. Information necessary to calculate cooling loads at various locations and orientations is provided In the special comfort cooling information provided with this manufactured home. To determine the required capacity of equipment to cool a home efficiently and economically, a cooling load (heat gain) calculation is required. The cooling load is dependent on the orientation, location and the structure of the home. Central air conditioners operate most efficiently and provide the greatest comfort when their capacity closely approximates the calculated cooling load. Each home's air conditioner should be sized in accordance with Chapter 22 of the American Society of Heating, Refrigerating and Air Conditioning Engineers (ASHRAE) Handbook of Fundamentals 1989 edition, once the location and orientation are known. INFORMATION PROVIDED BY THE MANUFACTURER NECESSARY TO CALCULATE SENSIBLE HEAT GAIN Walls (without windows and doors) .................................... "U" -09 Ceiling and roofs of light color ......................................... "U" .04 Ceilings and roofs of dark color ....................................... "U• .04 Floors........................................................................ "u• .09 Air ducts in floor........................................................... •U- .09 Air ducts in ceiling......................................................... •U" NA Air ducts installed outside the home ................................. •U" .25 The following are the dud areas in this home: Air ducts in floor........................................................... 90 sq. ft. Air ducts in ceiling.......................................................... NA sq. ft. Air ducts outside the home ............................................... 56 .5 sq. ft. U/O VALUE ZONE MAP WA NH MT NO VT ME OR MN ID WY SD WI MI NY MA RI NE IA NV IL IN OH Pp CT NJ CA.> UT co Ks �,140 VA DE MD AZ p,t NOS SCh ZONES U -VALUES v$ i= AL OA' D.w; 0.118 AK TX33� r 0.096 y HI p w _ FL 0.079 V=OK - p = Not OK = Not Applicable = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 3. 1. Zoning Requirements -Setbacks -Easements t Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Frg-Bracing 2. Soils; Special MH Support Sketch 6. 3. Sewer; Location -Test -Fall -C/O -Concrete Electric 4. Water; Location -Test -Easement Needed (Sketch) 9. 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Roof; Shthg-Roofing 6. Gas; Location -Test -Wrap;-/ /" L'ft. / /'Nat. or/ /"L"ft./ PLPG 12. 7. Well Clearance & Disconnect 8. Utility Clearance 1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements Date Soils; Compaction -Structure Stability Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE H9ME INSTALLATION (Plans) OK except #'s Zoning R quirements-Setbacks-Easements ootings; Size -Spacing -Marriage Line i s; Test -Demand -Valve -Connector Iectricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector ater• est -Regulator -Connector ater and Sewer Connected -C/O to Grade -HD Approval 8. Gas ang Electricity Tagged 9. Ti owns -Type -Installation Cert. Cert. of Occupancy Permanent Foundation Only; License Decal Data/ - Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels i j Date Card B-1 Date Card B-1 1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI j 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval i 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓ = OK 0 = Not OK = Not Applicable = Not Ready RESIDENTIAL (,4 Date Card B-1 Date Card B-1 Underfloor (Plans) OK except #'s FRAMING (Permit) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 41. 2, Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth Bearing Walls over Girders & Floor Nailing 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Fig. Depth 44. 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth Headers & Beams -Size & Bearing 5. Stemwalls, Main; Steel-Blockouts-Wrapped Garage Fire Protection Framing 6. Stemwalls, Garage; Steel-Blockouts-Wrapped Property Line Firewall & Openings 6a. Hold Downs and Special Anchors Ext. Doors -One T -Check Garage 3rd Story, 2 Exits 7. Slab, Steel -Wrapped Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 8. Piers -Fireplace Ftg.-Steel Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Siding -Nailing Veneer 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Stucco Mesh -Drip Screed -Fd. Vents -Under. lr. Access 11. Water Pipe; Test -Anchors -Regulator -Service Test Glazing Area -Glass Protection -Skylights -Plastic 12. Electric Underground Shear Walls; Nailing -Bolts 13. Plenums & Ducts; Clearance -Material -Support -Ins. Brace Interior/Exterior Wall Panels 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Insulation -Walls -Ceilings 15. Access & Ventilation Infiltration -Walls -Windows 16. Insulation Date Date Date Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s Ext. Steps -Door & Sidelight Protection -Landings 17. Water Htr.; Vent -Access -Combustion Air Baffle Smoke Detector 18. Water Pipe; Test & Anchor -Nail Protection Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection Bedroom Exiting 20. Shower Pan; Test, First Floor -Tub Access G.F.I. & Bath Fixtures & Tub Access -Spa 21. Test Tub & Shower, Second Floor -Tub Access Elec. Trim & Subpanel, Breaker Sizes & Labels 22. Gas Pipe; Sixe & Anchors Stairs & Rails 70. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date 72. ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or Al Insulated Neutral Q Yes Q No 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector 84. A.C. Unit Disconnect, Electrical -Plumbing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Water Well, Disconnect, Electrical, Plumbing MECHANICAL (Permit) OK except #'s 87. 35. A.C. Ducts Insulation & Support 88. 36. Vent Fan, Exhaust above insulation 89. 37. Condensate Drain & Overflow, Size & Grade 90. 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 91. 39. Attic Access & Platform if Furnace in Attic 92. Water & Sewer Connected -C/O to Grade -HD Approval Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) Date FRAMING (Continued) t• 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rhr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One T -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents -Under. lr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor Q Yes 82. Following Instld./Drive J Yes ❑ No/Walks J Yes :1 No/Planters ❑ Yes ❑ No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (530) 538-7541 PERW PERNO. (Rev. -;2/96) APPLICATION AND PERMIT ASS EST PARCEL NUMBER 028-260-012 ZONING U BUILDING PERMIT OWNER BARTH, TERESA TELEPHONE 533-5547 SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS P.O. BOX 46, BANGOR, CA 95914 1279 _ CONTRACTOR'S NAME EXECUTIVE HOMES TELEPHONE 891-6992 CONTRACTORS MAILING ADDRESS 3042 ESPLANADE, CHICO, CA 95973 CONSTRUCTION LENDER Fireplace LENDERS MAILING ADDRESS Total Valuation $ 69 066.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee 504.50 -2= $ 252.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUIL5726 ES LA PORTE RD . BANGOR Energy Plan Checking Fee $ $ PERMIT FEE $ 295.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.0023.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑x Other SPECIFY Solar or heat um water heater Water piping 15.00 15.00 Each as water heater or vent 15.00 TYPE OF WORK New 10 Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: NEW MH PERM FND EX SITE (REPLACES HOME THAT BURNED) Gas piping sysiern 1 - 5 outlets 15.00 15.00 Building sewer 15.00 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE $ 65.00 ELECTRICAL PERMIT Filing Fee 20.00 Main Service 200A OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER 0 License Class (-40 Lic. No. IO q OS S2 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. XI have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier StcLf a P*Lt a Policy Number I y S % IS "f7 1 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that f I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall rthwith omply with ose provision X Date _ b --;i- Signature of Applit - (5wher ❑ Contractor VAgent An OSHA permit is r uired for excavations over 5'0" deep and demolition or construction of structures over 3 ories in height. Main Service zooA To I000A 46.00 NEw CONST. DWELLING OCCUP. 3.5♦t so I ( OR ADDNS.NEW CONST. MU IC-0U�TLS.T. IET NON-RESID. BRANCH CIRCUITS @7.50 APPARATUS 8 SINGLE OurLET CIR. 1.00 EX. OCCU . OUTLET OR FIXTURES BAL p I.50 MED Ex. Occup. oirT> s AESI6.DE. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 4 3.0 MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 403.00 HAZ. . - D. F I CD PARC PD HD ISSU This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date 7-30-02 PERMIT EXPIRES ON -30-03 ate Receipt No. 3 5 414 7 $ 8 3 - 0 0 // 360690 $ 320.00 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT D2 ' COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County renter Drive - Oroville, California 95965 - Telephone (530) 538-7541 IRO, (Rev.,2��6) APPLICATION ANIS PERMIT D'R.1 ASSESSOR PARCEL NU — I ZONING BUILDING PERMIT y ' OWNER TELEPHONE T -7 SO. FT. OCC. BUILDING VALUATION FLc�o1> : X� I o2a� j J Q I VAV ee(feI r- �� 35y1�f7 0 -t � -�'ee Pat<�s g_ A PERMIT FEE _ bIrz> ELECTRICAL PERMIT Filing Feel 20.00 OWNER'S MAILJN(i, ORE6S� CONTRACTOR ANAME TELEPHONE gel - 6992. 23.00 Z CONTRACTO MAILING ADDRESS T 200A To 1000A 46.00 CONSTRUCTION LENDER'S MAILINn74 DWELLWO UP. Fireplace i ACC. BlD8. Total Valuation $ CO T. NON-RE81D. ECT OR ENGIrI ARCHR!N I LICENSE NO. Filing Fee $ 20.00 Permit Fee $ — ARCHITECT OR ENGINEER'S MAILING ADDRESS Plan Checkin Fee $ BuaoSII.7o�s LQ , Energy Plan Checking Fee $ gF4 W f.-0 tz PERMIT FEE $ LOT NO.."_;� 7 UBDNISION'SHAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome 0e-00ther SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 - / TYPE OF WORK New 1� Addflion ❑ Remodel ❑ Utilities the es ❑ Installation ❑ Or ❑ °oprr XJ4gr Describe Work: Q Q.L� moms_', Gas piping system 1 - 5 outlets 15.00 Buildingsewer 15.00 Mobile Home S G W (020.00 FLc�o1> : X� I o2a� j J Q I VAV ee(feI r- �� 35y1�f7 0 -t � -�'ee Pat<�s g_ A PERMIT FEE _ bIrz> ELECTRICAL PERMIT Filing Feel 20.00 Main Service OOAOROV ORLE6S 23.00 Z Main Service 200A To 1000A 46.00 NEW CONST. DWELLWO UP. OR ADDNB. i ACC. BlD8. 3,5¢so FT. CO T. NON-RE81D. MULTI -OUTLET RRAN[:N f:IRMJIR @7.50R>r Ex. Occup. OUTLET OR FORURES`e 11w BAL .SO Ex. OCCU FIXEO APPUIS. OR OUTLET6 RE810. EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 I PERMIT FEE $ Y,5 0 MECHANICAL PERMIT Filing Fee 1 20.00 1 HOOD! 6.50 PERMIT FE_ $ Mobile Home Installation Fee I $ Energy Inspection Fee I $ Occ CONST. TYPE TO AL FEE $ O HAZ. D. FE FLOOD I CDF IVCEL tV I HO ISSUE This permit Is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work Indicated above for which fees have been paid. By Date PERMIT EXPIRES ON COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: '� ASSESSOR PARCEL NUMBER 0 Z (o d— 0 12, " Proposed Building Use: �( Counter Technician: K, C Date:y ' Z"!�' �Iteemms required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. L� 1.. Plot plans, 3 or 4 sets, signed by the preparer of the plans. J 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. p-1' 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. P'4. Engineered truss details and layouts in duplicate. No faxes! ti �Energy compliance design and supporting documentation in duplicates 3 6. Manufactured homes:Data sheets and installation instructions'1Vlarriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ T. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet-si ng ed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required items are received. 1. Date Received By ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... ❑ 12. Hazardous Material Form............................................................................... 0 13. Other'' _ .... RZFees ing items needed to issue the permit. (May require additional plan review upon receipt of the following items.) as shown on the attached Schedule of Fees Due Sheet ....................................... ❑ Statement of Intent for Non -heated and A/C Buildings ................................. ........ ►!'�❑ 17. . Sanitation and plot plan approval from the Environmental Health De artment in ❑ City of Chico Plumbing permit ........................ ... ............. 18. California Department of Forestry plan approval paid. Sent bi(C) . ❑ 19. Planning approval for (A) Use: O� (B)Parking: arcel Check: ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... ❑ Encroachment Permit for driveway from the Public Wgrks Dept. (construction approval prior to occupancy). P, 22. Pre -Inspection for i'� . �-� /" . F-" pl required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ...................... ❑ 26. Letter of Signature authorization................................................................�... 4 '�'�MI127. Recorded copy of Agricultural Acknowledgment Statement .................................... ❑ 28. Manufactured home utility clearance............................................................... ❑ 29. grant 'ting violatio and/or expired permits......................................................... 1A_ 0. Deed, 1M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: When issued Telephone and hold for pickup. I have been informed of e a ove items an r quire�nents for obtaining a building permit. Applicant: Date: 4 4 1. Index permit application for the above items numbered: T Plan Check Letter 2. Additional items required Contractor, designer, owner, was advised of the above data by Vphone, ❑ mail, ❑ counter, by Date: VZ Contractor, designer, owner, was advised of the above ata by ❑ phone, ❑ mail, ❑ counte b Date: Plans reviewed by: _Date: � , �O Plans approved by: .& _Date: Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Date: Yellow: Building Division fi �. Environmental Veal peci ist Date f ��. Boa 8/96 y E.H. USE ONLY Piot Pian dttachad ' rZcorn Atsscle®d Sent to G.D. I TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Te respf�grfi� S7a6 lAfort Aj-- - Owner Location AP# Plan Approved for: Sewage Disposaly Water Supply: Public V Private'Well ! Clearance for L/ dwelling. Other Hold final for: Final clearance O.K. for: NOTE: Environmental Veal peci ist Date f ��. Boa 8/96 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE: CALIFORNIA 95965 - TELEPHONE (530) 538-7541 { SCHEDULE OF FEES DUE OWNER. ! a O� ✓�k PROPOSED BUILDING USE 1. BUILDING PERMIT FEES --Balance Due ........................................................ ^� ry $ J C. --Additional Fees Due ............................................ $ --Additional Fees Due ............................................ $ t / --Revised Plan Checking Fee ................................. 2. SCHOOL DISTRICT FEES $ 41-rA (aid at District Office) 4—/WfSHERIFF FEES (paid at Building Division) Residential .................................... Units x $360.00 = Commercial (sq. ft.) ...................... x $0.03 = $ Sq. ft. 4. URBAN AREA FEES Residential ............................ x = $ # Units Amt. Commercial (Sq. ft.) ............. x = $ Sq. ft. Amt. 5. RECREATION DISTRICT FEES 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER A.P. # Oa -1-60-0121 DATE G , Z_,57' z L_ RECEIPT # DATE REC. G 4 x-3. -02, 2n - n At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the pj#n checking process. APPLIC DATE Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Building Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 6/00) Building Permit umber: Owner Name: Residential Construction Requirements IMPORTANT This set of plans and specifications MUST be kept on the job site at all times and it is unlawful to make any changes or alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship shall be in accordance with recognized good practices and of a quality prescribed for the specific use in the 1998 California Building Code (1997 U.B.C), 1998 California Plumbing Code ( 1997 U.P.C.), 1998 California Mechanical Code (1997 U.M.C.) and the 1998 California Electrical Code (1996 N.E.C.) COMPLY WITH ITEMS CHECKED BELOW aYour parcel lies within a designated 100 -year flood plain. Finish floor, electrical, H.V.A.C. equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required Note: We will normally accept the following as compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on.top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24" above grade, or engineered design required). 3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than 1 foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. Page 1 of 2 Building Permit Number: Owner Name: Parcel lies within the State Responsibility Area (SRA). Comply with attached requirements. ❑ Fire sprinklers are required in this structure. ❑ The following parcel map requirements shall be met.- All et: All structures and � �e,uipment including overhangs shall be clear of all easements. A setback oM SY�o�'feet from the side and 30 feet from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the edge of the right of way shall be clear of structures and equipment except for a 2 foot overhang. (j Expansive soil may be encountered on this site. This condition may require the foundation to be designed by a California registered engineer or licensed architect. Page 2 of 2 s D PLUMWiG r1..L C' ., KaECM$ CHE D Ur ( s 1.Y Wrnj CURRENT EDMN UMG AND UPC. ON" pu S'c' 1/ t l = 02 a s /,4 02 �j i 4b; °I f 111 I bdrm To s W L�: �a > U "® MOTE: See the a,�akchedYzrl — - �•• - , 1 F Pr •L P r oa O t �c �� �� ages Z I Po It TL�- CDF FIRE SAFE REQUIREMENTS 2- daO AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. [V 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards [� 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other app..:rtenant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [ 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [ry 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. Ki 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. 0 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [�} 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [ 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of .3--, [ 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [ 1. Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. 1. All parvels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. [� 2. For parcels less than 1 acre, local jurisdiction '\ shall provide for the same practical effect. See Other Requirements below. { 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r fi_lal inspection of a building permit. Page 2 of 3 0 k 1 AP # PERMIT # AME [ 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [ 1. Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. 1. All parvels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. [� 2. For parcels less than 1 acre, local jurisdiction '\ shall provide for the same practical effect. See Other Requirements below. { 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r fi_lal inspection of a building permit. Page 2 of 3 W, b 9Z) AP # PERMIT # NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [K If Building Setback is Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area -not to exceed _0% of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat t Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3 WV17/DECOR Woodland Park Series Model 4483) ?—Bedrooms. 2 Baths • 1,279 Square Feet 1 46-0"ik l waw. WALK-IN i o I,"_.:,.UTILITY _�_� �.._L__c..;..... .: KI `'t CLOSET', " 1_ E 1.........:..1._:_i_.._ __ -' HEN ... LL ... H_;..:.. MA5T R I ;._........_. _ ::;....:_._ .. AG W ,.._ -!.. BAT F :..t.»..1 DIN! r BEDROOM _�-- --! _ _1_._! ._t_;: --- _: !. 1 On ENTRY 26' 6„ LU Z - O t j4 -, -•-' = ENTRY tt I i ! W --L.—b I BEDROOM {_ .:i: -LIVING ROOM i..._1. F -2"X12'-10" iT-6"X13'-O" OPT. OVAL TUO 1 2 �- W Oi � o ENTRY 13u ejV, 7A OPT. RECE55ED ENTRY al E 1. Owner's Name: IQl' (;A JDd,(jh= 2. Assessor's Parcel Number: 0 C .10o— Q �-- 3. Installer's Name: X Q(`.".T\Vo Ao 4. Is the site currently under permit? Yes[ ] No[Vf1`Permit No. 5. Is the site an existing site? Yes[ No[ ] (If yes, furnish two plot plans). 6. What is the electrical rating of the mobilehome? LOC) Amperes. 7. What is the mobilehome site circuit breaker rating? 8. What is the electrical rating of the mobilehome site? � Amperes. 9. Is the main service remote from the mobilehome site? Yes[ ] No[ ] If it is, what is the rating? Amperes. 10. Is there any other electric load to be served by the mobilehome site electric service (i.e. well, garage etc.)? Yes[ ] No [� If yes, please identify the load and size: a) The mobile home site: // __ Load- Amperes - b) The main service: Load- Ahnperes- 11. Type of gas service at mobilehome site: Natural[ ] Propane( None[ ] 12. Size of gas pipe at the mobilehome site from the meter or tank: `^ inches. 13. What is the gas pipe length from the meter or tank to the mobilehome?i,2.2�(R,) 14. What is the mobilehome gas demand? B.T.U.* *(This information is not required if the pipe length is less than 6 feet on natural gas or less than 50 feet on propane). THE OTHER SIDE OF THIS FORM MUST BE COMPLETED IN ORDER TO PROCESS THIS PERMIT APPLICATION May 1995 Ott ; i�Ba wG DEP a , ^ppROVEV 8.5 Mobilehome Manufacturer: ,Q,"CVl)rM Manufacture Year: 200 If other than single wide, furnish Setup Model Number: yyS - 3S Width . (ft.) Length: (ft.) Tagalong or Expando Size -j)-(ft.) x (ft.) On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural setup sheets. FOOTINGS: Wood pressure treated or foundation grade[(,] Other: SUPPORTS: Concrete block] Other: Provide Tie Down Specifications for all Mobilehomes: Pier Footings Sizes and Location SINGLE WIDE MULTI -WIDE Line I Line 1 Lime 2 Line 2 ................................................................................................ Main Beam Line2................................................................................................ c2 Line 1 Line 3 Line 2 ................................................................................................ Main Beams .................................................................................I............ Lina 2 Line 1 ................................................. ine S Tag or Triple ine 4 ine I I Line 1 Piers: Size minimum: r1l i x "L Spacing maximum: I T ` O` From ends -maximum: 01 Line 1 Openings Size minimum: Each side of openings with width over: ` Line 2 Piers: Line 4 Piers: Size minimum: x [Z`1 ]. Size minimum: [ ] x [ Spacing maximum: b o Spacing maximum: ` From ends -maximum: o ` From ends-maximum.- Line nds-maximum:Line 3 Roof Loads: Size minimum 36Y'3o Ivi-3o Z.N�3oI 'So -3o Location (from front): I —®, I 1g I -V 3a' 3" Hg' Line 5 Roof Loads: Size minimum: Location (from front): 0, P 5'l tido �`��p►�o-C�'-r� �.D . 24'-0" NOTES; 1) This floor plan may be built as an exact mirror imace about the length and/or width axis. 2) Egress window(s) shown with less than 5.0 ft2 vent area meet egress requirements through sash removal per window manufacturing instructions, located on the eindow. 2 1 36'•X58" I V. 46 :2� C?TID'i�1 i € 2xS ?=7j2x4 I lG:i+ir7i P 1y LMW 1i4{. 12u"p_L. 1 ^vuu L. . / I i U', FOiI LOAM MAX, HT. I S� E15' WI 1 , 24'-0" NOTES; 1) This floor plan may be built as an exact mirror imace about the length and/or width axis. 2) Egress window(s) shown with less than 5.0 ft2 vent area meet egress requirements through sash removal per window manufacturing instructions, located on the eindow. 2 1 36'•X58" I V. 46 k� :2� C?TID'i�1 i € 2xS ?=7j2x4 I lG:i+ir7i P 1y LMW 1i4{. 12u"p_L. 1 ^vuu L. . / I i f?vI! FOiI LOAM MAX, HT. I S� E15' WI 1 C?T (A2) F; I �' ' �� .3 L ?7s, I No. a 2 LPU1 oJ I '�J)OPT 0'-D' I D'-0' 480,? i1 6 10'-0' 32 32_22_ 5900 2 B l5' -U' 4 6 z� (2 ?OF 30'-3'+30'-5" 6900 3 9 15'-0' 4 6 WO Wg` i ON LIVING ROOM n&C 30 260.6 SO. T. ((g \--/ 1,"s'-O'14R'-4' 4800 A 4 1D'-0' 32 32 z _ �g - - 60'Pi - B '^:-o3tes 2' NoHr1 is P ,2nd - r•� - _ —ls I' 0'T 2 STAND4.4D OPT I 2rS PIER Zai pa? Rel. 30#LL 1OuD.L. REC $tiiRY to FRiSV ; LOrAmN I FROW PEER 10L^S IAAX. HT. Ss". 119' W2 1 - - IB OS POSV UPUF1 "!, �n,TR1 7, ; D'-0" 0'-0' 16'00 1 Al LOAD 10'-D' 32' 31sT 7 l l 11 f 18'-3" 1 B'-5' 9000 2 g! 15'-0' 30'-3' 30'-5' 9.000 3 Al 15'-0' 5 B J� Y� 48'-4'1 6300 4 sl 10'-0' 32' 31'6 24'-0"148'-0' l - - 5A - AI BI B � 3 C •Ind.a`ys Z' }?°Orin, a P�,-'red 10 RECEFL(SEE ELCT.SP:CS.) ELECT. PN: BOX , WOODLAND SHr. sWRcH 5X10 WR REG. ��� FLOOR PLAN•! OF Zj¢ LIGHT FIKTURE (' AIR SUPPLY vizi WI © THHt7 sra `$i ® EXHAUST k CFIE:NG FAN 0 CEILING R"GfSTER SHEARWALL , '� A 13 -4 X 4B4 NODE' WOODLAND PARK 12 SMOKE DETECTOR [] 5UP. 04r POST 11 30 00 O13' -4'x 48'-0 HIGHLAND PARK/SUNCREST A 2 DOOR BELL TRANS. R* -R: URN AIR CR;LL sJ`3h6'-1'-0' c 4483J k� 2"x Z"x 3/16" STEEL ANGLE DETAIL "A" CHASSIS FRAME W.. 1/4" GRIPPER PLATE (2) REQUIRED 1/4" GRIPPER BASE 1/2-13UNC-A307 x BOLT WITH NUTS (4) REQUIRED 01 1/2" SCH 40 PIPE RISER WITH 01/2" ADJUSTER HOLES AND 3/8" THICK TOP PLATE 02" SCH 40 PIPE STAND WITH TWO 01/2' ADJUSTER HOLES ABESCO ABS PAD #503 STEEL FRAME SEE DETAIL "AA i LNAM pl, pg. 3/8" CAD PLATED BOLT, NUT & WASHER COACH 'C" FRAME— COUNTER BORED FLUSH WITH BOTTOM AT 8" O.C. (8) REQUIRED 2" CHANNEL-- 114- STAND BASE TE y _ 1' x1 T /4 =. _ TEK ST5 REQUIRED ABESCO ABS PAD #503 (2) 1/4" GRIPPER BASE 1/2" A307 BOLT- ' (2) REQUIRED 3/S"x 6"z 6" STEEL PLATE 1/20 A307 BOLT--'/ (2) REQUIRED 35" MAX _ TO BOTTOM OF PAD o— _o " 01/2"x 3" C.R. LOCK PIN WITH 01/8" BRIDGE PIN I _ 0 MINE � COACH "J" FRAME 1/4' GRIPPER 1/4'x1-1/4" PLATE TEK STS (4) REQUIRED t- 1/4" GRIPPER BASE 1/2' A307 BOLT (4) REQUIRED C -BEAM J -BEAM ATTACHMENT ATTACHMENT r 8' 1/2" DIA_ HOLE (8) A*. 09/16 HOLE (TYP) �+-- — 30"l� STAND BASE STEEL FRAME TOP VIEW TOP VIIEW° STATE APPROVAL •-o Ii Nado �Er� �- , � a 0 s 1� EIS w . V > E guc _Olyi� ry � ii i ` n U TUE-1 PERMANENT ° o c' `n FOUNDATION SYSTEM V O a SUS GUAM COMPANY 5851 FLORIN - PERKINS ROAD ' Ci SACRA1dIFWM, CA 95823 PH: (804) 382-8831 FAX: (916) 383-5207 WAYNE T. POLVADO, PE -LISTING N0. F94249 SHEET I of 3 N W ED GENERAL NOTES GUS GUARD TUF-1 1• DESIGNI IDADS_ LIVE LOAD - 30 L.B. 16. FOUNDATION BLOCKS IS% 16'x12" POURED IN PLACE AT GROUND LEVEL MAY FLOOR LIVE LOAD - 40 PSF BE USED AT INSTALLERS DISCRETION ALTERNATIVE TO PADS. WIND LOAD - 80 MPH EXPOSURE "C" SEISMIC ZONE "4" *SNOW LOAD 100 PSF (SEE NOTE #15) SINGLE WIDE COACHES DOUBLE/MULTIPLE COACHES 2. THIS FOUNDATION SYSTEM IS DESIGNED TO BE CONSTRUCTED ON E= 2' MIN. / 8' MAX. E= 2' MIN_ / 11' MAX. A FAIRLY LEVEL SITE WITH NO EXISTING SOIL PROBLEMS. S= 6' MIN. /16' MAX. S= 6' IWIN_ / 22 MAX. 3. CHASSIS BEAM SUPPORTS SHALL BE LOCATED AND SUED FOR THE LOADS AS SHOWN IN THE "MOBILE HOME INSTALLATION INSTRUCTIONS". VARIES 10'-70' (SEE TABLE ON SHEET #3) 4_ IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.S.) CAN OCCUR, E S S�_El — S E +I MANUFACTURED HOME SHALL BE READJUSTED WHEN DS EXCEEDS 1/4", OR WHEN IT WILL ADVERSELY AFFECT MOBILE HOME UNIT. El 5. CARRY ALL FOOTINGS DOWN TO FIRM, UNDISTURBED SOIL. FOOTINGS rRIDGER SUPPORT AS ARE DESIGNED FOR 1.000 PSF TOTAL LOAD SOIL PRESSURE, AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. COMPACTED SAND Q (TYPICAL) a �[ MAY BE USED TO FILL LOCAL VOIDS UNDER PADS, LJ U 6. STRUCTURAL STEEL FABRICATED ACCORDING TO AISC SPECIFICATION_ E _(3-�- 0 _ ED^ WELD ACCORDING 10`AWS SPECIFICATIONS. ELECTRODES -370 PLATES -ASTM u f A36 BOLTS -SAE GR 5=ASTM A449=ASTM A3725. 8' NOM. 7. THE GUS GUARD ASSEMBLIES SHOWN ON THIS PAGE SHALL BE LISTED ANDEl LABELED BY BSK AND ASSOCIATES FOR THE FOLLOWING LOADS: 2' NOM• D ALLOWABLE LOADS: HORIZONTAL VERTICAL PADS IN ANY PAIR MAY BE STANDARD M.H. FOUNDATION ROTATED 90 DEGREES OR PIERS AS RECOMMENDED BY PVC SERIES GUS GUARD TUF-1 2200# 6000# OFFSET TO OTHER SIDE TO THE MANUFACTURER OR THE SUPPORT GUS GUARD MGP PAD 2260# 6000# AVOID CLEARANCE PROBLEMS. ENGINEER. TYPICAL THROUGHOUT PAD TTP) GUS GUARD E -Z TIE PAD 2200# 6000# 8. DURING PRELIMINARY INSPECTION; THE ESTIMATOR SHALL ENSURE THOJea..- MOBILE HOME CHASSIS BEAMS ARE OF STANDARD SECTION. g. EIItSTING COACHES MAY BE RETROFITTED TO RESIST SEISMIC FORGES -sY •='• STATE APRROVA INSTALLING GUS GUARD TUF-1 UNITS AS 5t10WN ON THIS PAGE OF TYPICAL �b �. r . {•: FOUNDATION -PLANS. 10. THE GUS GUARD TUF-1 SYSTEMS ARE SAFE FOR INSTALLATION IN FLOOD PLAIN AREAS WHERE DEPTH OF FLOODING DOES NOT EXCEED THE HEIGHT y• t OF THREE FEET. f ter,T. MULTIPLE UNLIT INSTALLATION IS ACCEPTABLE PROVIDED THE NUMBER OF TUF-1 UNITS UNDER EACH UNIT IS � `' t' � tgd THE SAME AS SHOWN REQUIRED PER EACH UNIT. tp,, >i�'c`� p y < ... . 12. SINGLE -WIDE UNITS REQUIRE ADDRIONAL RESTRAINT. s (SEE SHEET #3) ' �EQ P."L y, w cm � 1 o " 3 �► 13. ALL METAL CO IPONENTS AND ATTACHMENTS ITEMS SHALL BE PROTECTIVE COATED. e r G.t : , < (r L+. U` 14. WHEN CONCRETE SLAB IS 1N EXISTANCE. PAD IS NOT 0 CA E `� u < y cli REQUIRED. ANCHOR STAND TO CONCRETE SLAB WITH TUF —1 PERMANENT x °z o o s z FOUR (4) 1/2% 3 1/2" EXPANSION ANCHOR FOUNDATION SYSTEM �x � � � a 7E o 15_ GUS GUARD TUF-1 FOUNDATION SYSTEM PROVIDES O 7 0 ALLOWABLE SNOW LOAD TO 100 PSF WHEN INSTALLED ARESCO-GIUS GUARD COMPANY h y WITH EXISTING STANDARDS REQUIRED BY COACH 5851 FLORIN - PERKINS ROAD Ca MANUFACTURER OR REPLACE THEM ON A ONE TO SAORANEWTO, CA 95523 ONE BASIS. PH: (800) 382-8831 FAX: (915) 383-5207 WAYNE T. POLVADO, PE—LISTING NO. F94249 SHEET 2 of 3 W. m 0 W a CL C7 V Ul W - an r 0 N m m m -a, 3/4" DIA. x 18" LG. 1/2"x 3 1/2' 1/2'x 8" LONG (4) REQUIRED EXPANSION ANCHOR, ANCHOR BOLT 3/8" CAD PLATED BOLT, tQUT a- WASHER (4) REQUIRED (4) REQUIRED COUNTER BORED FLUSH WITH BOTTOM AT 8" O.C. (8) REQUIRED 1 C CONCRETE PAD INSTALLATION " POURED IN PLACE 16x16x12 CONCRETE FOUNDATION INSTALLATION CHASSIS FRAISE � u— _ LIGHT HEAVY—WEIGHT PLASTIC PAD MISTALLATION 1/4" GRIPPER. PLATE (2) REQUIRED 1/4" GRIPPER. BASE 1/2-13UNC-A307 x 4" --'- BOLT WITH NUTS (4) REQUIRED Si 1/2' SCH 40 PIPE RISER WITH 01/2' ADJUSTER HOLES AND 3/8' THICK TOP PLATE 02" SCH 40 PIPE STAND WITH TWO 0.1/.2' .ADJUSTER. HDL`S. - -- ABESCO ABS PAD 0503 STEEL FRAME 3a MAX IdULZ'I-112DS TJir�fS D SINGLE VIDE N�iM TO BOTTOM LEN6TH yHD�{ OF HOME OF PAD HOME 24 26 28 UP TO 44' 8 B B 12 i 44'-1 Io 66° 12 12 12 18 - 01/2"x 3" C. R. 66'-1' fo 88 20 20 24 24 LOCK PIN WITH NUMBER OF TUF 1 r 37" i8 if2' I LENGTH OF HOiIE / 141 VADTH OF HOME 74 16 UP TO Olt' 6 6 6 6 4t'-1' b 8 8 8 6 66'-1' fo 80 10 1 10 10 14 01/8 BRIDGE - REOUIR_D NUMBER OF TU? -1 REQUIRED. PIN NOTE: SINGLE VADE UWTS REQUIRE (4) E-2 TIE PADS. GUS GUARD iUF-1 PERS ARE TO BE PLACED AT APPRO]QYATELY,EDUAL INTERVALS ALONG EACH FRAME RAIL TUF-1 PERMANENT FOUNDATION SYSTEM AWSCO-GUS GUARD C5;FA QTY 5851 FLORIN - PE21;'IIdS ROAD SACMNEE N TO, CA 95823 PH: (800) 382-8831 FAX: (916) 383-5207 TATE APPROVAL tiz . < z` z u 0 < -N. RO _ i 4 �` fy C C)0 y y O (U o� _ �o°� o z 90) H 5 H WAYNE T. POLVADO, PE—LISTING NO. F94249 sHEET 3 of 3 0 i= I L.t= Pio . 822 k,,6/18 ' 02 All 08:27 I D :EXECUTIVE HOMES FAX :530 8O91P Y7 f Document ordiyl 25 -Jun -2002 2002-0032903 -, 'Has not been compared with n•NU t1'111CN RECORDED ntnlL To: original aul"rr. COUNry BUILDING DIVISION BUTTE COUNTY RECORDER 7 COUN1'1' CFAT1,,11 DRIVF, 0IRWALLF. CA 91961; ACRICA)LI'UitAL S'1'ATEMEN'1' OF ACKNOWLEDGMENT FUR RE' 'S[I)ENTIAL DEVELOPMENT Sc:ction 211-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building Perrnit. The property described herein is adjacent to land or included within all area zoned for agricultural purposes, and residents of this property may be subject to inconveniences en• discoitlfort from the use of agi-Icultut'al chemicals. including, but not limited to herbicides, pesticides, and fertilizers; and from the pun:vuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and hal-vesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from lionrtal, necessary fflrnl operations, Ali that real property situate In the County of Butte, Stale of California, described as follows: tletng a port of S%cdun 27; Towne hep 14'Nmth, Range 3 }~11181, KU.B. & M„ bdn8 mora partieadptly doaorlbod as fbilowa, to vrit: t:'llRftygNC1N(1 at a point marked by an Iron Pets in the Fsastelly line of the 13Aogor-FolbAatown Caunty n.nnrt as the 1?castar(y Unp of the 7nvm of gaugor, a000tt11111{ to the official map of paid T*Wtt filed March 12, 1 got In MAP hook 7 pt page 77, reoorda of Butte Ootulty, CWltbrula; thancq South 3 to 32' Wset 69 abet mom the Rttettuly line of said road to an Iron pre; theme t 56 tbet In w Anutlleesteriy direr tion to an iron peg inti Ilne ptuldl111 to 1116 Ruuthwesterly boundary of eald Lint 3A; tomos Norihea 71 West Iid as p Ilea the of to the kaetarly Nae of avid Bangor-Forbaetowu read M and Iron peg; eltenae North sJ ° 27' West I.f6 feat nlol� tits Sauthsasteely bouudety One of Lot 30, Wok to elle point of Itaginnhng. 1.)ate PROPERTY OWNERS: titins; of CillifornIR ) -Aiu:,ly of 430-4 . ) tb, \illlrl� l�,•%0Q.L _ before me, U ., 1'!T ,n 'A nom, , i ✓). , : , _ Ijcrsonallygn pea red "rC- F��� - V V known to me (or proved to me un the basis ot'satisfac(ory evidence) to be the person(s) whose names) Is/are subscribed to the within instrument and acknowledged to me that Ile/she/they executed lite Fame in his/her/their nuthoriaed e.apnclty(ies), and that by his/tier/their slgnature(s) on the Inslrunlerlt, the person(s) or file entity upon behalf of which file ptrson(s) acted, executed the instrument. tVt"i'iVCSS in �1 1 and officials al. V S "nature Seal: CHRISTY L. HINKLE COMM. B 1258485 6 COUNTY OF BUTTE �� G D / Q �� N in W Comm. Expires March 27, 2004 • �r /."4 MESIVEN I IAL 1JUIL.U/JVU tft:UUrrU / . �_ / y .i:.: ... �' ct- ADDRESS Remoin9 Life robe �cONSTRUCT/ON cone. ArcA. Func. AtJr. Plan Con- Sloro espoce Work- Fl. form. p—h Closet %chip DESCRIPTION OF BUILDING /d-la-qjl Cost —_..__ unitri _L S Cost C AssesHAP sr UCTURAL EXTERIOR ROOF. LIGHTING AIR CONDITION ta�ARCHITECTURE Light Sub -Standard Fiome Stucco on F/o1 4 Pilch Y Gob/t2 J. Wiring A.T. Conduit - Ntoli�q Forced Cooiin Jeoni ROOMS 8 5tondord Sheolhinq _ Siding__ Nip S B X. Cable A I/ Crnvily Humid. All v SPECIAL FEATURES Above -Standard ConcrtirBlockSAed IBook / Fixtures We Unit Cores Built -in Beds �enetleIt B//nde 1 r- �, Stories special , B.d D. T. a G Cut Up Few y Few �CheaP Ent. No// USE TYPE BrickShiny/es (_6,J Dormers Av .Medium F/onrUnit Living FOUNDATION Adobe - Shakes —Moray Specio/ 47/z /y Dininq Double Concrete F/oor.Joist: )( B.$B. r. Di G. Gutters _ Centrol- — � Duplex Reinforced_ xls►.y"X� PLUMBING __— _ Bed _ Apartment Brick 21d: "x - Brick shingle Poor I Good _ l _r, ;_l_ Bed _ Flat Wood.^r .'�'f t,•-,„ Sub Floor Stone Shake OilBurne_r__ — • Court Piers WINDOWS ri/e fi,rtureS Q I Motel D.H. Cosemenl rile trim 'waterNeoter lnsuloled Ceilin s Jtee/ Josh Composition Aulomol(c Fireplace Kitchen Units Li h1 Heavy lnsu/o led Walls screens Compo. Shin le 16as 1 lElect. DroinBd. r•nlusraUcrinN aFCnan . wwe NORMAL 01 GOOD I RATINB (E. G. A, F. P) AARGEL SHEET ,ZL OF SHEETS .42 iron.�------- BATH DETAIL Permit Amount Dole No. For YEAR YEAR A 9 Remoin9 Life robe /o cone. ArcA. Func. AtJr. Plan Con- Sloro espoce Work- Fl. form. p—h Closet %chip No. FINISH FIX TUR S SMOWER Floors Wolfs c. La ub T e I Grade St . .D. Finish /d-la-qjl Cost —_..__ unitri _L S Cost S 1 r A I/ 7S v SPECIAL FEATURES /U 91 G VFE IBook IS Cores Built -in Beds �enetleIt B//nde 1 r- �, COMPUTATION tv-''S .:_ - r, ' COMPUTATION Appraiser a Dole Unit Area o ; pl— a ,J` � —Un—if Cost 1, nit Cost t osl Ct= � n -R Cost ` ?� Cost,' n't CosI o I f"rr Unit OS/ 7 io. Cost =;OCA �n, Cost Cvs1._._. _ _ 74} 33 "'f Cost /d-la-qjl Cost —_..__ unitri _L S Cost 7S v 1 �' - IS 1 r- �, fOTAL NORMAL % GOOD R.G.L.N.D. -- -1 10-- X da 41k' COMPUTATIONS I M. '�'Jj (" ml r !.r- - - F --- X r r 'T'�-•P.:nS.Errlwtd�.-.+i4..r`e�,14�...Y�-w4..k�,:...+r"'�('-�'�I.,,,,.,y:+�., ��^'W'.1 ,.--r�--•i{: r...d�' .---^f"."..'._•'...x�.r ra,—-.—,,,r ,,,.-.� r � --.,ren 2 f 1r School District A.P. Number BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) (pro U / \ Building Department No. — 2-G o (al. Liurisdiction: City County Property Owner —1-26- or T14 Property Location/Address 4- or 62 f r + ~ o Subdivision Lot No. .................................................................................................................. : Residential DevelopmentSq. Footage ( Z No of Living Mobile Home Addition 'Supplemental to (Group R) Units Installation Conversion Permit # € f o* ��• �.`Q� '(No foundation inspection): .................................................................................................................. Commercial/Industrial New Addition Building Department Representative (Floor Plans reviewed by School District Sq. Footage (Including Exterior Roofed Areas) l,.ZsfQz Date District Identification No. School District certifies that n (Applicant) rbQ —` • J (Street Address) i - (Phone Number) (City) (State) (Zip Code) has complied with the requirements of Resolution No. D� `"� by payment of $ ' .s representing -7957 7 square feet. AB 2926 'a FULL MITIGATION $ School District Representative Date Paid by Check # Remarks: Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 660201a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm �V 17/DECOO Woodland Park Series Model 4483) 2- Bedrooms • 2 Baths • 1,279 Square Feet OPT RECE55EP ENTRY T�resf� l�r-��rL, 5qa6 $ Orr. wow. ----,: 1 O _,..,__;_.WING 1 1 ------' FI - -- -' 1 TV -� _ ._ .+. ..;...:..:......:..:_[ 1-:41orr..�. WALK-IN i oL—H`U7ILITY- T.- ITCHENi•%-i ` K MASTER CLOSET i I W F _ _=-i� ,4TH -r ._. 1 :....F- ° + i-- '- ..; DINING = I.. 1 T_...1.- _t5._... 1..:..:...:.1._ _._'_. _::.:. ._..._ .. - �_... ,r...; AREA BEDROOM 13'-6" X 131-0" ..:...:__ .:_;.... _ _ ; ----' � OPT. , ... E..1.. ... :.._ -- ,� ENTRY -� i 261-8" ._ �_•.:.:::t::s......t_.:� LU • I� ? O Orr / 1 ----�.._ _------ ENTRY ....�..�_j_ . 'BATH:; - -. r -L •BEDROOM '} '-211 x 121-10" s LIVING ROOM a ;g, 17-61,X 13'-O" 1 OPT. OVAL TUB I 2►- �W I 13uI ENTRY OPT RECE55EP ENTRY T�resf� l�r-��rL, 5qa6 I t �y _ _ 6 S,/ -751:1 4-0 ,3 N •r -J AP cd Q c� ,3 N -J Q 1:! � o it h 0 � t� rx ,3 FILE Ne . 8^c2 06/18 '02 Aft 08:27 I D :EXECUTIVE HOMES A41) b1'11EN REC-ORDER MAIL T'U: �60 111,11•rE COUN'I•V nU1LDIW; 1)IVISIUN �b 7 C'OUNTV ('EN'1•t',It DRIVE ORt)VILI_E. CA 91965 20102-010329103 Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 01:06PM 25 -Jun -2002 REC FEE .00 CONFORM 7.00 Cheryl Page 1 of 1 ACRICAIL;1'URAL S'1•ATEMFNT Oh ACKNOWLEDGMENT FOR RESih)ENTI.AL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building Permit. The property described herein is adjacent to land or included within all area zoned for agricultural purposes, and residents of this properly may be subject to inconveniences or discomfort from the use of HgOcultural chemicals. including, but not limited to herbicides, pesticides, and fertilizers; and fl•om the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary fiirnt operations. All that real properly situale in the County of Butte, State of California, described as follows: 13ein.8 a part of S%Wun 27, Townetdp 16 •Nntth, Range S East, M,I).B. & M„ being mors particA►aptly daaorlbed as fbilown, to wit. ('OMMENCING at a point marked by an Iron peg in the Fsasterly 11119 orthe Ralwor-rorbaetown (.'ounly 11t.ond 011 the Easterly lino of the Town of 19angor, Qoanrttilig to tate otlicial map of paid 1,0" tiled March 12, 1901 in MAP Book 7 0t pop 77, records of Flutte Cowtty, Colillbralk thenoo South 31' 32' West 69 lbet 010118 the F%R"-ly line of said road to rut tmn p*5; thence 156 feet In a Anuthemerly dlrecNon to on iron peg In a line parallel to site 8uuthwesterly boundary of Sold Lot 39;he cle oe Nvrtheaateriy 69 l4et on n Ilne p0ta11e1 rheto tlto Easterly 11119 of said Bangor-Forbiietewtt roar) M and 11 -on peg; noa North SJ ° 27'011t'�0rtt t �6 t6at 01009 rhe Sauthmte14y boundary One of Lot 38, hnok too the point of I,* Inirlg. a0 029r/SG i.ate )1It0.PrRTY UWNEJtS: (� F/,655,9 - State of California comity of 43LA-- i -e— On \iQknI✓ (S.-2 Z- before me, personally4peared A 123A<�_ T - - - _ _ personally known to me (or proved to me un the basis 01'satisfactory evidence) to be the person(q) whose namo(s) is/are subscribed to tile within instrument and acknowledged to me that lie/she/they executed the same In his/her/their authorized capncity(les), and that by his/her/their 819onture(s) on the instrument, the person(s) or the entity upon behalf or which the person(s) acted, executed the Instrument. WITNESS n7ji�rl and om5lal spot,- � / V n S s nature Seal: :- • CHRISIY L. HINKLE COMM. B 1258485 cc NOTARY NOTARY PUBLIC-CAUFORNIA Q i COUNTY OF BUTTE W Comm. Expires March 27, 2004 RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 21 -Aug -2002 2002-0043397 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. TERESA CHRISTINE BARTH AND THOMAS BOURKE BLACKSON REAL PROPERTY OWNERILESSOR PO BOX 46 MAILING ADDRESS BANGOR BUTTE CA 95914 CRY COUNTY STATE ZIP 5726 LA PORTE RD. INSTALLATION MAILING ADDRESS. IF DIFFERENT BANGOR BUTTE CA 95914 CITY COUNTY STATE ZIP THERESA BARTH UNIT OWNER (if also property owner, write "SAME') SAME MAILING ADDRESS CITY COUNTY STATE ZIP BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP 02-1680 (530)538-7541 B G PERMIT NO TELEPHONE NUMBER 8-21-02 �'SIGIWTUkEOF LdCALA OFFICIAL DATE EXECUTIVE HOMES DEALER NAME (if not a dealer sale, write "NONE") 92081 DEALER LICENSE NO. UNIT DESCRIPTION FLEETWOOD 2002 WOODLAND PARK MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAME NUMBER CAFL117A/B25268-WP12 48 X 27 PFS0738411/2 SERIAL NUMBERS) LENGTH X WIDTH INSIGNIAILABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSORS PARCEL NUMBER A.P. # 028-260-012 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE -County Recorder CANARY - HCD PINK - Applicant GOLDENROD -Building Dept. t �.� .; Fr �i'ii'UR. W w"! 'rf iikAl i- . ry1P111 .. 1 BUILDING PERMIT NUMBER: 02-1680 Address or location of unit: 5726 LA PORTE RD., BANGOR, CA. 95914 Legal Description of Real Property: A.P.# 028-260-012 SEE ATTACHED (x) Mobilehome/Manufactured Home () Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: TERESA BARTH Owner's address: PO BOX 46, BANGOR, CA. 95914 INSIGNIA OR HUD NUMBER: PFS0738411/2 SERIAL NUMBER OR V.I.N.: CAFL117A/B25268-WP12 MANUFACTURER'S NAME: FLEETWOOD YEAR: 2002 OFFICIAL APPROVING INSTALLATION• Yj DATE: 8-21-02 PHONE: (530) 538-7541 H.C.D. 513C LEGAL DESCRIPTION A.P. # 028-260-012 All that certain real property situate in the County of Butte, State of California, described as follows: BEING PART OF SECTION 27, TOWNSHIP 18 NORTH, RANGE 5 EAST, M.D.B. & M., BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS, TO WIT: COMMENCING AT A POINT MARKED BY AN IRON PEG IN THE EASTERLY LINE OF THE BANGOR-FORBESTOWN COUNTY ROAD ON THE EASTERLY LINE OF THE TOWN OF BANGOR, ACCORDING TO THE OFFICIAL MAP OF SAID TOWN FILED MARCH 12, 1901 IN MAP BOOK 7 AT PAGE 77, RECORDS OF BUTTE COUNTY, CALIFORNIA; THENCE SOUTH 31 DEGREES 32' WEST 69 FEET ALONG THE EASTERLY LINE OF SAID ROAD TO AN IRON PEG; THENCE 156 FEET IN A SOUTHEASTERLY DIRECTION TO AN IRON PEG IN A LINE PARALLEL TO THE SOUTHWESTERLY BOUNDARY OF SAID LOT 38; THENCE NORTHEASTERLY 69 FEET ON A LINE PARALLEL TO THE EASTERLY LINE OF SAID BANGOR- FORBESTOWN ROAD TO AN IRON PEG; THEN NORTH 55 DEGREES 27' WEST 156 FEET ALONG THE SOUTHEASTERLY BOUNDARY LINE OF LOT 38, BACK TO THE POINT OF BEGINNING. r 1 L -C Imo. CZC vo/vz) , TOI� . pian oL� . I . TRANSPORTATION OF CALIFORNIA N BER. SU81NE8S, AND HOUSING AGENCY DEPARTMENT OF HOU61NO AND COMMUNITY DEVELOPMENT 8683541. DIVISION OF CODES AND STANDARDS MANUFACTURED HOUSING PROGRAM MANUFACTURER CERTIFICATE nF nRiriN o ❑ CHECK IF THIS 18 A DUPLICATE MCO -ENTER ORIGINAL MCO NO. BFD (SINGLE FAMILY DWELLING) ❑ MUMH (MULTI -UNIT MANUFACTURED HOUSING NUMBER OF 2 TRANSPORTABLE SECTIONS COMMERCIAL rnerH: OCCUPANCY GROUP MMUFACTURE n2nVOOD HOM9 OX CALIFORNIA, INC. F C URER LICENSE NUMBER: 9534 T�a PO'a0X 1308 WOODLAND CA 95776 SUG TEO RETAIL PRICE SbrN C Slets ZI ' NIAg /► RER TRADE NAME: MODEL ME ANDIOR NUMBER: PATE BF MANUFACTURE: WOODLAND PAM 44832 2002 12/14/2001 ' sICI'1`Y R_QRA BSE ATB, R P . A ��((// AT8 C BRED T01: CALIF. DEAL NUMBER OR DATE OF N ER: TRANSFEREE DESIGNATION: Da1i XXXC01TX" HOMO 92081 12/14/2001 R OR SFEREE ADDRESS: 3042 11911ILKHADS CHICO CA 95973 8twi 1 N Y CREDITOR NAM CI (state)Z TRANS AMRICA ,Tf_mFfyd6kVfftWNMCN BLVD OVIT11 350 ; Blest CHARLOTTE NC 28226 CI Bhts i SE TION 1a MANUFACTURER SERIAL NUMBER 1 ; HOD INSIGNIA OR HUD LABEL NUMBER LENGTH WIDTH WEIGHT INCNEB INCHES POUNDS 1 CASL117A25268-c+IP12 PT90738411 576 160 20,440 I 2 CAtL117B25268-WP12 PY80738412 576 160 21,780 TRANSPORTER NAME; D B R TRA NBPORT TRANSPORTERADDREBS: BOX 179 ck DURHAM CA 95938 OEBTINATION FOR UNIT DESCRIBED ABOVE: Blm = NAME Bir" C Bloe p I Sen" under Peeeey of P" wdw the I"* o1 d» BU4 of Cenerr" ow the ebm terve ae ffm "."ed. Epaued en 12/14/2001 d WOODLAND YOLO CA re SIGNATURE OF AUTHORIZEO AGENT: alamusurom ORIGINAL (PWK) FORWARD COPY 1(wI11TE) FORWARD COPY 2 (YELLOW) GKPAR T1 COPY 3 (GOLDENROD) TO BE REF HCO 1&!.0.6105 I - (11117) . E INVENTORY CREDITOR, UNLESS THERE 18 NONE. THEN FORWARD TO THE PURCHASER (DEALER OR TRANSFEREE} E DEPARTMENT AT P.O. SOX 1828, SACRAMENTO, CA S3812•IS28. WITHIN FIVE 18) DAY& OF RELEASE. TRANSPORTER TO ACCOMPANY THE UNIT TO ITS DESTINATION, BY THE MANUFACTURER. 05/28/02 10:15 B I DWEL L TITLE 4 530 891'8753 RECORMid REQUESTED 8y. When Recorded Mail Document and Tax Stw/emen/t To; .�'�t Ir11r�SA4e. -� ` MCLS evorjee -31A 45ol1 ,Aaio Oro-734rjor Aly 4k OroY'Me, <A 9596.6 SPACE ABOVE THIS UNE FOR RECORDER'S USE The and QUITCLAIM DEED ers)gned grantor'(s) dedare(s) Documentary transfer tax is $ 17•, r'1 O City Tax is $ I 1 computed op fuR vatue of propedy conveyed, or r;�'< omputed on telt value Iess ""Of Gang or encumbrances remain" at time of sale, P-<1 Unlncorporsted Area City of ganga FOR A VALUABLE CONSIDERATION. racs4g of which is hereby acknowledged, -?.z5,3, UrU i7r t rare, l hereby remises, releases end quitclaims to Teresa Christian Barth and Thomas Bourke Blacks= as joint tenants the following described real property in the County of Buft, State of Catifornla: Beingo wit a of Section 27, Tawnghip 18 North, Range S grit, M A.B. & M., being ramie Partic4uly describetl as follows. COIVEIENCING at a point marked by an iron peg is the Easterly line of the B Easterly line of the Town of 1B wZ0r-F0fbsCtown County Road on the Bangor, according to the OtltcW map of said TovM filed March 12, I901 in Map Book 7 at page 77, records Of Butte County, California; them South 314 32' WM 69 feet alODS the Easterly line of said road to an iron peg, theQee 156 feet in a Southeastesiy direction to an iron peg in a tine parallel to the Southwesterly boundary of said Lot 38; thence Northeasterly 69 feet on a lice parallel to the Easterly lute of said Bangor-Forbmown road to and iron peg; thence North sS ° 2T west t 56 feet along the Sotttheasperly b0u4dwry In ofI& 38, back to the point of beginWng. OATED: STAT: OF GAUFORNK 40etA Otia PA AAAC COUNTY OF ON �, ..,�,rs ..�. �, •� .. _ _ _before me, appeared personeffy known tb M (or prov�ad fv rine an Mebzsfs of satisfactory evidence) to be the Person(s) whOse name(g) Ware yubScribeo to the within instrument and acknowledged to Ine that hersbe/they executed the same In histher"eW auftrized cape), and that by hislhedtheir signature(s) on the instrument the petspn(.), or the entity upon behalf of which'the persons) actad, executed (t instrument WItness my hand and Of loo seen. S'ronature jCARQLYN 0. EN%yL A— DT COWiM. 81197314 No" Pubw1caftmia wrmcoutm w comm. E* MI 3F (Rev gye) MAIL TAX STA EMS AS DIRECTED A13OVE QUITCLAW ai 0 NO.782 P002 IIIItlIlltlllllltllttlllllllltltl Recorded OffCcialyyRecords i REC FEE 7.80 I TAX 7.70 Of CANDACEUTTE J. GRUBBSReco I er ROSEMARYI I ®2 O M1st28aFeb-2802 Fa I Rage I of I SPACE ABOVE THIS UNE FOR RECORDER'S USE The and QUITCLAIM DEED ers)gned grantor'(s) dedare(s) Documentary transfer tax is $ 17•, r'1 O City Tax is $ I 1 computed op fuR vatue of propedy conveyed, or r;�'< omputed on telt value Iess ""Of Gang or encumbrances remain" at time of sale, P-<1 Unlncorporsted Area City of ganga FOR A VALUABLE CONSIDERATION. racs4g of which is hereby acknowledged, -?.z5,3, UrU i7r t rare, l hereby remises, releases end quitclaims to Teresa Christian Barth and Thomas Bourke Blacks= as joint tenants the following described real property in the County of Buft, State of Catifornla: Beingo wit a of Section 27, Tawnghip 18 North, Range S grit, M A.B. & M., being ramie Partic4uly describetl as follows. COIVEIENCING at a point marked by an iron peg is the Easterly line of the B Easterly line of the Town of 1B wZ0r-F0fbsCtown County Road on the Bangor, according to the OtltcW map of said TovM filed March 12, I901 in Map Book 7 at page 77, records Of Butte County, California; them South 314 32' WM 69 feet alODS the Easterly line of said road to an iron peg, theQee 156 feet in a Southeastesiy direction to an iron peg in a tine parallel to the Southwesterly boundary of said Lot 38; thence Northeasterly 69 feet on a lice parallel to the Easterly lute of said Bangor-Forbmown road to and iron peg; thence North sS ° 2T west t 56 feet along the Sotttheasperly b0u4dwry In ofI& 38, back to the point of beginWng. OATED: STAT: OF GAUFORNK 40etA Otia PA AAAC COUNTY OF ON �, ..,�,rs ..�. �, •� .. _ _ _before me, appeared personeffy known tb M (or prov�ad fv rine an Mebzsfs of satisfactory evidence) to be the Person(s) whOse name(g) Ware yubScribeo to the within instrument and acknowledged to Ine that hersbe/they executed the same In histher"eW auftrized cape), and that by hislhedtheir signature(s) on the instrument the petspn(.), or the entity upon behalf of which'the persons) actad, executed (t instrument WItness my hand and Of loo seen. S'ronature jCARQLYN 0. EN%yL A— DT COWiM. 81197314 No" Pubw1caftmia wrmcoutm w comm. E* MI 3F (Rev gye) MAIL TAX STA EMS AS DIRECTED A13OVE QUITCLAW ai 0 STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT DIVISION OF CODES AND STANDARDS REGISTRATION AND TITLING PROGRAM STATEMENT OF FACTS, This unit is a U Mobilehome ❑ Commercial Coach ❑ Floating Home ❑ Truck • Camper Decal (License) No.(s) Trade Name `'Le le�rLv ct oAnd �,Z I/We, the undersigned, hereby state: Serial No.(s) C' �Tr �� 714/13 �s�t P- cvjo/a Dealer Report of Sale # The Above Described Unit Has Been Placed On An Approved Foundation System In Accordance With 18551 Of The Health And Safety Code. I/We finther agree to indemnify and save harmless the Director of Housing and Community Development, State of Callfarma, and subsequent purchasers of said unit, for any loss they may suffer resulting from registration of the above-described unit in California, or from issuance of a California certificate of title covering the same. I/We certify under penalty of perjury that the foregoing is true and correct. Executed on �� _ at ��l! '\ , (Date) r (City) (State) Signature(s) I Printed name(s) Address 34 City HCD 476.6 (REV 12/00) r kx�eC,-,tj t.,.e- //bxt.eS State '973 .SECURITY MOBILE HOME SHOW/NORTH, INC. 2 0 2 6 7 _ - EXECUTIVE -HOMES 3042 ESPLANADE PH. 530-891-6992 _ - CHICO, CA 95973 11-42288 T DATE TO _ TO THE. ORDER OF f _ �� I � ' DOLLARS, B' Y"":�••. Well argo8ank,NA Califomia • www.welisfargo.com FOR 7 1120 20 26 711' +1: 12 104 288.21:0.1.700 7600411' - - - r - r . Z ' . r • 4 C' ��� � T� r � j• r+ s �� N• � �° �-��- �/�� �- Owner W Mailing Address &, AI& Contractor / U L COUNTY OF -,BUTTE — 'DEPARTMENT OF PUBLIC WORKS '7 County Center Drive Oroville, California 95965 ' Tel ephe?e:. X34-4541 APPLICATION AND PERMIT la/ /! c / /�O 4e 'Z I_ephone No. _ BUILDING SO. FT. T OCC. I BUILDING VALUATION Mai I i ng Address 4r Main service Fireplace Total Valuation EA. ADD•L 100 AMP Main service Telephone No. Permit Fee Building Address ��/.��� Plan Checking Fee &/or Penalty Permit Fee NEW CONSTR. NON.RESID. PLUMBING l f /VfX1 r`rNPC� ! ����� PERMIT FILING FEE Each Trap Repair drainage or vent piping A. P. No. �"^ z(f/ �-- �� Zoning & Planning Water piping Each gas water heater or vent Fees W. C. ^Sanitation FireDept. Fire Zone Use Permit Gas piping system 1 - 5 outlets EQA Parking Plans Parcel Declaration Parcel Map 60' R/W Improvements Each additional outlet Building sewer Bldg..P.lans-Rec'd I Parcel Approval Plans Approval Lawn sprinkler system NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER 0 Permit Fee ELECTRICAL Single Family QY Duplex Mobil Home ❑ Others ❑ CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: X License No. I am exempt from the Contractors License Laws of the State of California. Permit Fee WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. Y ®I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. Classification PERMIT FILING FEE Main service 600V OR LESS 100 AMP OR LESS Main service EA. ADD•L 100 AMP Main service OVER 600V 100 AMP OR LESS Main service EA. ADD'L 100 AMP NEW CONST. ( OR ADDNS. DWELLING OCCUP. X ACC. BLDGS. NEW CONSTR. NON.RESID. (MULTI -OUTLET BRANCH CIRCUITS NON-RESID. \SINGLE OUTLET CIR. . Ex. OCCUp(OUTLETS OR FIXTI]RES EX. Occup.(FIXED APPLNS. OR OUTLETS (RESID.) EA) Temporary service Mobile Home Facilities Misc. Wirinq I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X l� l [f , l 11 J,]/1 i. /it 1 Date Signature of Permitee or Agent 4 9,7z Receipt No. /l White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant MECHANICAL PERMIT FILING FEE Heating Cooling ,@ $3.00 1.50 1.50 1.50 1.50 1.50 .30 5.00 2.00 $3.00 5.00 2.50 25.00 1.00 FEE >.50ea 0@25Q IAL @ 10¢ 2.00 10.00 15.00 6.25 $ 1$:011 99, @ FEE $3.00 Ventilation Hood 1 1 2.00 Permit Fee $ $ Land Development Fee $ TOTAL PERMIT FEE $ rkj This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIR.-E-'CTOR OF PUBLIC WORKS By Com' I �i.l _ Date 7 ' _ 2 Building permit expires Date COUNTY OF•BUTTZ - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Orville, California 95965 Tel ephoge: -534 4541 APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X Date Signature of Permiitteeeor Agen Receipt No. , ZZ— White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF OaLIC WORKS BY Date -Z -�Z Buil ' g permit expires Date 7- -L- �7 BUILDING Owner R SQ. FT. OCC. BUILDING VALUATION Mailing Address/'Q A zZ le hone No. Contractor Mailing Address Fireplace Total Valuation Telephone No. Permit Fee Building Address % Plan Checking Fee&/or Penalty Permit Fee N d - ,r/ f"J PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 A. P. � ��p — 7/ Zoning & Planning Water piping 1.50 Each gas water heater or vent 1.50 F s Sawi�atien Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Plans Parcel Declaration Parcel Ma P 60' R/W Improvements p ovements Each additional outlet .30 Building sewer 5.00 RIAQ .elawoeftc'd Parcel Approval Plans Approval Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER2] permit Fee $ ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 (� 600V OR LESS Main service 100 AMP OR LESS 5.00 Single Family ® Duplex ❑ Mobil Home ❑ Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER 100 AMPs0ov OR LESS 25.00 Main service/ EA. ADD'L 100 AMP 1.00 OR ADDNSNEW T DWEACCLBLDGS,LING CCUP. 'j)20sgft CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW CONSTR BRANCH CIRCUITS) NEW CO ID ( BRANCH CIRCUITS 2.50ea NEW CONST. POWER APPARATUS 6 NON.R RESID. (SINGLE OUTLET CIR. EX. Occuo(OUTLETS OR FIXTURES BAL01 FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESIO.) EA) / 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ QQ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation: ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. r I certify that in the performance of the work for which this \ permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL N0.1 @ FEE PERMIT FILING FEE J$3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X Date Signature of Permiitteeeor Agen Receipt No. , ZZ— White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF OaLIC WORKS BY Date -Z -�Z Buil ' g permit expires Date 7- -L- �7