Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
017-140-030
i ®s 30 ROCKY NILES 4534 Jason Ct, Chico Contr: Doyal Wall, Chico Permit#1533-84B,P,E,M(new single family) Oi�� X90- 03e- 0/ 7 30l7 y0,--030 v zi-ma 11 _ L A N D G F N A T U R A L W E A L T H A N D B E BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 ' TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 April 14, 1994 Directors Mortgage Loan Corp. 2735 Esplanade, Suite B Chico, CA 95926 RE: Recent Correspondence A.P. #011-29-0-030 Attn: B.J. Parsons With reference to the above subject and your letter dated April 14, 1994, the house you reference at 4534 Jason Court, 'Chico is currently in an FR -2 zone which allows residential construction. If your house is destroyed by fire or other disaster, it, may be recon- structed if in compliance with the -building, sanitation and zoning codes in effect at the time of reconstruction. Should you have any questions concerning this matter, please contact this office. Yours very truly, SR:dms Scott Rutherford Supervisor, Building Inspection Butte County #7 County Center Dr. Oroville, CA 95965 Atten: Building Division Directors Mortgage Loan Corporation DFsCS I %S&CTOR Mortgage Bankers Directors Mortgage Loan Corporation DIPCCTORS. B.J. Parsons 2735 Esplanade, Suite B Loan Consultant Chico, CA 95926 Bus. (916) 898-8098 Fax (916) 877-3853 Res. (916) 893-2319 Pager(916)896-6149 RE: APN# 011-290-030/ Owners: Niles 4534 Jason Court Chico, CA 95928 To Whom it may concern: April 14, 1994 This is to request a letter that will verify that if the above property is more than 50% destroyed, it can be rebuilt, due to the property being zoned Residential (FR2), legal non -conforming. If any additional information is required to provide the above mentioned letter, please call Penny Brown at 91.6-877-7641, at our Paradise Branch. If you will please also call her when the letter is completed so that we may pick it up from you, so that we don't have to wait for the mail as we are trying to close a loan on this property as soon as possible. Thank you in advance for your cooperation in this matter, anything you can do to expedite this would be greatly appreciated by all. Sincerely, B.J. rsons Se i r Loan Officer n ti PERMIT No. X1533-84B,P,E,M PERMIT EXPIRES ` () OWNER ROCKY NILES CONTR.. Doyal Wall, Chico ASSESSOR PARCEL 51-34-30 LOCATION. 4534 Jason Ct, Chico OFFICE COPY fi Address GAS Date . Meter By ELECTRIC ai Meter By Date l\ a r; Temp. Power Pole / Called PG&E f Temp. Elec. Service Called PG&E . Temp. Gas Service Called PG&E JOB FINALED (Date) A, Signature Owner: Permit No. ENERGY CERTIFICATION 4534 Jason Ct., Chico LOCATION A.P. No. DESCRIPTION OF INSULATION ROOF Material Thickness(inches) EXTERIOR WALL Material Fiberalass Batts Thickness(inches) 6n" CEILING Batt or Blanket Type Thickness(inches) Loose Fill Type Fiberglass Batts Minimum Thickness(Inches) 13 3/4" Area covered(ft.2) 1500 FLOOR, ELEVATED Material Fiberglass Batts Thickness(inches) 6P FLOOR, SLAB Material Thickness(inches) Width(inches) FOUNDATION WALL Material Thickness(inches) Brand Name Thermal Resistance (R Value) Brand Name Owens-Cornina Thermal Resistance(R Value) R19 Brand Name Thermal Resistance(R Value) Brand Name Owens-Cornina Number of Bags 45 Wt. per bag 25 lb. Thermal Resistance(R Value) R30 Brand Name Owens-Corning Thermal Resistance(R Value) R19 Brand Name Thermal Resistance(R Value) Brand Name Thermal Resistance(R Value) I hereby certify that the above insulation was installed in the above building in conformance with the State of California Energy Requirements. Loerke.Insulation Co. 432518 FIRM NAME/OWNERSTATE CONTRACTOR'S LICENSE NO. . n .c irLJ 15/ �- �_ _�, _ December 10, 1984 SIGNATURE OF INSTALLATION APPLICATOR DATE Y.; I hereby certify the above insulation and all required items as shown on the Building Department approved plans and attachments have been installed as required by the State of California Energy Requirements. All equipment, devices and materials are of the quality prescribed or are specifically approved by the State of California. FIRM NAME1OWNER (Please �print) . `AJC ST=Tl OF GENERAL CONTRACTOR/OWNER STATE CONTRACTOR'9 LICENSE NO. i DATE THIS CERTIFICATE MUST BE ON FILE WITH THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE POSTED WITHIN THE BUILDING. January 1984 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS. f 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise— Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this Mter, os need additional explanation, please contact this office immediately. ;-9 I �- .:1- t0 COUNTY OF BUTTE DEPARTMENT OF PUBIC WORKS ' 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, -or need additional explanation, please contact this office immediately. 2 A& 5' V e'o,,z o 7i rl' 9 Z76 f� Vq Inspec tor�' / l�y�L' Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this. Inspector Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this tter, or neeq additional explanation, please contact this office Immediately. '&Tku�' A/C -2 �' Inspector COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORDS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise— Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. Inspector - Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this mat er, or need additional explanation, please contarl ce immediately. ,8 v41* Jl �- Inspector_,_ Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this Inspector_ -- Da J OK O = Not OK = Not Applicable * = Not Ready MOBILEHOMES MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except p's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except H's 1. Zoning Requirements -Setbacks -.Easements 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/O -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Biacing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Locatiort.Test-Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card -BI Date Card -BI Date Card B-1 Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date J = OK O = Not Cj< - = Not Apalicable = Not Ready RESIDENTIAL'(Single and Duplex) Date UNOJERFLOOR Plans OK except #'s Date FRAMING (Continued) v ing requirements -Setbacks -Easements .../ 481f3roperty Line Firewall &Openings Ftg., Main; Soils-Steel-Elec. Grnd.- /J /" Ftg. Depth Ext. Doors -One 3' -Check Garage -3rd story, 2 exits l tg., Garage; Soils -Steel- / /"-Ftg. Depth tairs; Width -Headroom -Rise -Run -Landing -Fire Protection tg., Porches & Decks; Soils -Steel- / /" Ftg. Depth lywood on Roof Overhang -Attic Vents -Rafter Outriggers eStemwalls, Main; Steel-Blockouts-Wrapped-Slab 52. Siding -Nailing -Veneer temwalls, Garage; Steel -B lockouts -Wrapped -Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access iers-Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 5,ear Walls; Nailing -Bolts ` 6. LGas Pipe; Size -Anchors , (yam Water Pipe; Test-Anchors- Reg ulator-Servi `fest ( t Y 2a _ _ lectric; Underground 121, 41 Atv- K Plenums & Ducts; Clea nce-Material-Support-Ins. 3 irders-Sills-Anchor Bolts -Joists Vent -Cripples Card -BI Date Card -BI Date 45 151M Card -BI Date / / Card -BI Date fr!� Card -BI Date Card -BI Date Card -BI Date Yfr Card -BI Date Date AL (Plans) OK except q's Card -BI Date Card -BI Date Date PLUMBING (Permit) OK except q's ter Ht.; Vent -Access -Combustion Air (8 Ext. Steps -Door & Sidelight Protection -Landings Smoke Detector W. Furnace; Vents -Clearance -Comb. Air-Connector- In Garage; Above Floor-Ducts-Mech. Protection UfO'-Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test�*ttngs & Ar berg --Nail KFatEction Bedroom Exiting 0 G.F.I. &Bath Fixtures &Tub Access Elec. Trim & Subpanel; Breaker Sizes -Labels -t?—Shower Pan; T t First Floor -Tub Access 18. Test & nd Floor -Tub Access 49—Be. Pipe; Size & Anchors tairs & Rails Ireplace or Stove; Clearances -Hearth �Flec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Z Card -BI Date Kit. Fixt. & A liance; Grnd.-Air Ga-Cookin Clearance. /. ' Card -BI Date Card -BI Date 6 . Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except q's Garage Fire Door; Swing -Landing -Closer A.C. Duct in Garage -Damper ixture & Transformer Clearance -Ins. Protection Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection Elect Receptacles Spacing -Lights &Switches at Doors Size Boxes & No. of Conductors -Stapled 7s- Ib., Elec. & Mech. Equip. Listed for Location ? � . Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. Romex Installed Close to Edge of Studs & C.J. Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water /I'nsulation-Foam-Looked in Attic 4Ej' es kff-2 Appliance Circuits in Kitchen &Conductor Size uard Rails &Deck Construction -Post Caps -.26.-ftbfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or AI . Vents & Crawl Hol Door -Drainage & Wood -Earth Clearance Looked under Floor Yes 27. Range Circ. / / g Cu�or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral �_ s [_1 No following instid.: Drive des ❑ No; Walks ®'Yes E] No; Planters ❑Yes i�<o i5ellervice-Riser Conductors & Ground -Main Disconnect 7A stucco; Brown -Finish p. Clearances; Panels-Motors-Mech. Equip A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet wtlothes Closet Light -Shower Light 78. ents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 9. Water Well; Disconnect, Electrical, Plumbing Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date f Card -BI Date 6 Ventilation throughout House Card Date Date Card -BI Date MECHANICAL (Permit) OK except q's -ti—A.C. Ducts; Insulation & Support Glass Protection Corrections from Previous Inspections _84, -Gas Test -Meters Tagged; Gas -Electric 85. W.g>;+ 'S onnected-C/O to Grade -HD Approval OD�rent Fan; Exhaust above Insulation nergy Compliance Certificate -Other Certificates ondensate Drain & Overflow; Size & Grade -e4—Furnace-Vent; Access -Comb. Air -Return Air Vent -115V outlet -35--Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI ' Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Comments at Final: Date FRAMING Plans OK except q's S' Is; Proper Material & Anchors 3 Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound B aring Walls over Girders & Floor Nailing Draft Stop in Walls (rat proof) Fire Stops; Furred Ceilings -Stairs -Chases -Tub 4i_, -Header & Beam -Size & Bearing 42. angers -Post Caps -Anchors -Connectors Cing. Joist-Rftr. Ties-Purlin- Roof _Brac.-Truss-Shthn_q.-Rfn_g._ Fireplace Ties or Type A Flue -Fireplace Throat 4 ttic Access; Size & Romex Protection -Draft Stop -Ins. Baffles drm. Windows or Exiting Doors -Sill Hgt. & Dimensions 4 age Fire Protection Framing (NOTE:Anentrymust be made each time youvisit jobsite) COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Orovi'lle, Galiforn?a 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT PERMIT NO. Jr � ASSESSOR PARCEL NUMBER ZONIN 1-3 7i BUILDING PERMIT OWNER / T =Hp� SO. FT. OCC. BUILDING ION �VALUA v OWNER'S MAILING ADDRESS c(p �D ZA� I S 0 CONTRACTOR'S NAME TELEPHONE CONT ACTOR'S MAIL[N A RESS e_ly%&D Fireplace C O`t�Y,STRUCTION LENDE b -9 A-V/ �� UNKNOWN Total Valuation $ toss Filing Fee $ 10.00 LENDER'S MAIL D _ eO Permit Fee $ 3 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ♦� $ ARCHITECT OR ENGINEER'S MAILING ADDRESS - Permit fee $ e BUILDING ADDRESS ''ll ,/� cy� PLUMBING PERMIT FiIingFee 10.00 10 1-- Al 01ma d1 Each Trap J 2.00 � Solar Water Heater 20.00 01= puc o 0) Water piping 5.00 s LOT NO. SUBDIVISION NAME PARCEL MAP J - Z Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE SF)YEN Duplex ❑ Mobi lehome ❑ Other SPECIFY Building sewer 5.00 , Mobile Home S TG FW 10-00e TYPE OF WORK New Addition❑ Remodel❑ Utilities❑ Installation❑ Other ❑ Describe work: — Permit Fee $ -6,91,co Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service e0v OR LESS 10.00 1000 AMP OR LESS Main service EA. ADD'L 100 AMP 2.50 NEW OCONS. DWELING R ADDNST ( ACCLBLDGS.CC P 21/20sgft , CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full f rce and effect. License No.%23 (a Classification � ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW NON.RESID R BRANCH CIRC ITS) 2.50 ea NEw CONSTR POWER APPARATUS &) NON.RESID. SINGLE OUTLET CIR. Ex. Occu 20@SOC OR FIXTURES BAL®30 p�OUXED A FIXED APP LNS. OR EX. DCCUp. OUTLETS (REST D.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating (f , Cooling Hood 3.00 �, Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all Iia 'lities, judgments, costs, and exp nses which may in any way accrue again aid Coun in onsequ ce of th granting of this perm' , XA99( Date 7 Signatureo pplicant — Owner ❑ Contractor Agent El An OSHA pe mit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ , Occup. GROUP I TYPE OF CONST, v I I PARX Pa HD ssu This permit is hereby issued under the applicable provi- sions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRE R OF PUBLIC WORKS By. Date - P /R MIT EXPIRES 'Date �Z t Receipt No. / iJel WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT RESIDENTIAL PLAN CHECKING GUIDE (S.F., DUPLEX, & MISC. ONLY) L .ems Bldg. A. GENERAL Voning requirements (sideyards and parking). aluation. Signature by R.C.E. or Architect (if required). B. PLOT PLAN omplete parcel size and dimensions. oetbackq, sideyards, easements, etc. ther buildings or structures. Grading, fills, drainage. Permit # # i-_�� — ey!Z C. FLOOR PLAN -or Complete to scale plan with dimensions. oE� Required windows for light and ventilation (Sec. 1405). Required windows for second exit (Sec. 1404). 4. Allowable glazing for energy requirements (20% max. per State law). Human impact glass (Sec. 5406) . Required room sizes, ceiling heights (Sec. 1407). G.F.C.I.'s in baths and exterior outlets (Sec. 210-8). 8. Light fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. 9. Locations of water heater, heating & cooling equipment, other electrical or gas equipment, and plumbing fixtures. .350'p- Garage firewall, door size, and closer (Sec. 503(d)(4)). JA--' 1 - 3'0" exterior exit door (Sec. 3303d). „12 -.'Fireplace location. ;13. Smoke detectors (Sec. 1413). D. STRUCTURAL DETAILS Foundation plan complete enough to construct building. ,2e. --Floor construction details complete enough to construct building. ,.3— Elevations and wall construction details complete enough to construct building. Roof construction details complete enough to construct building. J3� Fireplace construction details and calcs if over one-story in height. Sufficient data and details to satisfy energy insulation requirements (State law). E. MISCELLANEOUS ITEMS TO LOOK OUT FOR CX plywood on exposed locations and overhangs. 21`�' Stairway details (Sec. 3305). ✓3.�ardrail details (Sec. 1716). Brick or stone veneer (Chapter 30). �Fxterior plaster - weep screeds (Sec. 4706 & 4708). groper roof pitch for roof covering (Chapter 32). '7. Rafter ties or bearing ridge beam. Garage door or porch header sizes. AK Adequate bracing. I Living area over garage - complete 1 -hour separation required including supporting walls and posts, etc. .. Two (2) exits on three-story dwellings (Sec. 3302). a� 6� �i k v ' C a yo _s All o2lo 74 el Slo7 409 c / /T7 Return to DPW OFFICIAL RECOP S BUT ECOUNTY-CALIF. - t��jp�t�1 AAY 18 f 136 AM 193 CLERIC - RFCJiiU%R FEE AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT FOR RESIDENTIAL DEVELOPMENT n Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort arising from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occa- sionally generate dust, smoke, noise, and odor.' Butte County has established.agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such . inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: SEE EXHIBIT "A" ATTACHED HERETO & MADE A PART HEREOF FOR LEGAL DESCRIPTION Date: 5/17/84 NOT COMPARED WITH nR!(,IN!AL DOCUMENT PRO TY OWNER ROCKY NleS State of California ) On this the 17th day of May , 1984. , ) .SS. before me, the undersigned Notary Public, personally' County of Butte ) appeared RICKY NILES known to me to be'the.person(s) whose name(s) i s tc[At,SEAL subscribed to,the within instrument and acknowledged M. A ROSS that.' he executed the ' same for the purposes o - NOTARY PUBLIC • CALIFORNIA COLUSA COUNTY therein contained. My Comm. &.pires Dec. Iz. 19t IN WITNESS WHEREOF, I hereunto set my hand and official seal. r Notary Public Present A.P. NO. We. 1. ., .'!viA4: �1y EXHIBIT "A" DEScl-IPTION: All that certain.real property situate in the County of Butte, State of California., described 'as follows: A portion of Section 19, Township 22 North, Range 3 East,M.D.B. &,M., more particularly described as follows: Parcel Two,.as shown on that certain Parcel Map recorded in the office of the.Recorder.of the County of Butte, State of California, on Febru- ary 13, 1973, in Book 45 of Parcel 2•1aps, at page. 24. TOGETHER [•IITH a non-exclusive easement for road purposes and public utility purposes over a strip of land 60.00 feet in width lying 30.00 feet on each side of the following described centerline in the I -lest one half of Section 19, Township 22 North, Range 3 East,i BACHMAN & March 26, 1984 ASSOCIATES Mr. Jim.Glanders i - Butte County Building Department #7 County Center Drive k Oroville, California 95965 ` RE: Mr. Rocky Niles t AP# 51-34-030 Our job -#84-037 Dear Uim: I have reviewed the referenced parcel of land and have the following comments: 1. The property is located in Butte Creek Canyon adjacent to Butte Creek. k t 2. The proposed building site is on a flattened -out dredger pile and lies approximately 300 feet fromIthe present river edge. 3. The apparent high water mark for this area is evidenced by a bench and anarea of berry vines. ; 4.. The proposed site lies approximately 5 feet -above said bench. 5.. In my opinion; if the proposed house is constructed with a wood floor that is a minimum of 2 feet above the adjacent ground, it will be above the flood plain. This elevation is referenced by a rebar in a rock mound approximately 150 feet south of the.. centerline of Jason Court Very truly yours, C. W. BACHMAN CWB:ch 'ENGINEERING SURVEYING PLANNING DESIGNING 3012 The Esplanade, Chico, California 95926 Telephone: (916) 342-4136 File No. BUTTE COUNTY (For Action 1, 2,3) Public Works Dept. (For Information ✓) Director Dep. Dir. Sec. Ad. & Br. Mtce. Shop & Yards Bldgs. & Grnds. Bldg. Insp. Admin. Design Engr. Bridge Engr. Constr. Engr. Surveys Mopping Transp. Land Dev. Drng. /S.I. Sub. & Pcl. Maps Permits Addr. O , 1 V Vi O � -47 DOYAL WALL General Contractor Post Office Box 3868 J �n Chico, California 95927, Telephone (916) 893-4642 %4j ' r Q • • I �� � I X Q" � S l o (� 'I 1 s (`1 o x J0 0 to W ® 0J LJJ OW a >- O ® �' ) CIL Lki ry z O , 1 V Vi O � -47 j .. �� •^•� Inwa -ANS A5 NOTED BELOW. (Do u las Fir may be subsbluted ~e Hem -Fir is specified.) CHDSIZE SS OF nl OF 1112 OF CON -11 F SS HF Ini HF nJ Hf CON Hf 240 F tnt) F F r1SI F On F TOP CHORD 211 6 36' 8 36 • R" 36 • " 6' 2X 4 32' 1" }1' 2 21't0" 25' 0" 3n1 3" 27' 8"24. 7" 22' 0" 33' 3" 32' t" 30' 3" 2A' 6" 25 7" BOTTOM CHD. 2 X 4 36• A" 33'4" 27' 5" 36' " 32' 8" 1 28'10" 3• A" 6' A" 36. 5" 2'fU" 28' 4" WEB MEMBERS tae STANDARD OR STUD GRADE HEAF d2 MEA4FIR OA AS NOTED ON DESIGN Y A 1 r: e H - w .. .. OFF PANEL POINT SPLICE (T2) 2X6 R4.OX4.5,T44 TO 3h' A" PEAK JOINT DETAIL A. 8" 2x6 R4.UX6.0,T46 36' 8- 2.0 4.0, 4 2X4 R2.4X4.5,T2.5/4 TO 33. 3" 2x6 k4.0X4.5,T54 30' 0" 2.0 4.0. 4 2X4 R4.OX4.5,T44 33' 3" 2.0 4.0, 4 PANEL POINT SPLICE (TJ2) 2X6 R4.8Xb.O,T56 TO 361 8^ OFF PANEL POINT SPLICE (92) Symmetrical R2.4X6.0, T2.5/6 TO -361 A" About R2.4X4.5,T2.5/4 TO 301 0" Ceraerline PIE NO.: 7 -3b-b- 47♦ (,21) 4/3 DATE: 4/23/79 SPG AEI•: 5 -IS -78 DES. BY: t N CK. BY: Ten 2X4 R4.OX4.5+,T54TO 331 3" NO SPLICE R1.6X3.0,T3/1.5 TO 36' N" R1.6X3.0,T'31 TO 24' 0^ TJ2 GENERAL NOTES: (uresa oolen"x apo.I1W) \ 1. InalaYron is enhely eo reaponsEmly of me respecovo Fonux 2. Ae W.". renis., arid perm.. to -1 bust forces to MLe9ygnee arae poweee by Wie s. 3. De,lgn mes'ory epnd ' of use m rrorcprosive anv.erlmem a. Oftgn asaumea lateral braorlgr 3' m t Uoro. 12' oc bottom Mad 5 Deaton eawmlaa M be." r v"". SMm p wedge it nK4ua;y. 8 C bliss 0 L/M betl.eln al ports. T. AOepry trarna)p a aaaumW. •. S. 1.3 oorlsrxlolrs lateral bat.. g re shown 9. Impact bi0prlp ar lalarr baorq remr11rr1errpee wlNre shown 10. Lr19 a.ia d pWe Perow.%.Aar o alord.• SPAN TO 3h' H" SPACEn p4.n" I).1'. 6.0:12PITCH 4/3 COOFIGUPATIDN LL+OL ni" ROoF = 37.n P5F OL. ON CEILTt,G = 111.0 PSF e TOTAL nESIGN LOAD = 47.0 PSF + e 5 PSF CEILING REOUCTTOh TAKEN, AXIAL STRESS ONLY t! LOAD DURATTON INCRFASF = 1.15 .NAXIMIM TRUSS MEMBER FORCES WEACTIOt-:= 1512 T 1 •2493 N 1 223U 1 -606 9% 757 T 2 -2133 8 2 1485 -BUTTE CUNTY eQuBl C V4^ w,r at PANEL POINT SPLICE (932) R4.8Xb.0•T56 TO 36• A" k4.8Xb.0,T54 TO 30' 00 NO SPLICE P3.2X4.5•T34 TO 36' 8" R2.416.O,T2.5/4 To 30' n" k2.4X4.5,T2.5/4 To 24' 11- BUILDING DEPARTMENT APPROVED 3 EQUAL PANELS BOTTOM CHORD SPAN TO 3 6 '^ DOUf, - FIR SPkI)CE-PINE-FIR R3.2X6.0 TO 36' 8" k3.2X9.0 TO 36' P" R2.4X7.5 TO 281 R" 83.2X7.5 TO 34' 4" R2.4X6.0 TO 28' 0" R3.2X6.0 TO 27. 7" R?.4%4.5 TO 21' 6" R2.4X7.5 TO 21. 0" R2.4Xh.0 TO 2n' 7" OOIIG-FIR SPkUCF-P)NE-FIN T46 TO 361 A" T46 TO 36' A" T49 TO 33' 3" 745 T() 3011n" T3h TO 30' 0" T56 TO 27'10" T2.5/h TO 25' 1" T2.5/h TO ?3'4" T?.5/4 TO 17' 0" T2.S/4 TU 15'In" TMIXEIAL coNmc"m / R5.v" r wd prem' 20 w4 se". • • erref.sW r.ael stM ab ars AMrr0.alr 1 " 100 -e 1114217111 *@(KATE SIZE Of PLATE IN INCHES. MOM (01601fied by I1ree, _T'): a Nam Pat .e. in.. t2'%41 Te"1 r0 Py , N,o per ho* r .10"..26•' o c. Hr" M YI N,, 1.1.0411111111111: Sn"u W of mmmum gra" 6 spades as note. IDwgl" Fir may 8.5000 turdtalee by prMa "R'): $0 twat per ee.in.. 10'•. N' Iprle TaaM an erslrad Il.o Par "e* r .26•'..0" c.c. Hr" lira m Nle b. e.b MIW wvbr. Hemfrt a apecvhW t AwP w (+1otr+eW A ped -AN") la a p.oal 8.5000 op.waor wl" evsy Nw rw a U.61 sire brae o,~ ttSeR. ' G" eWra1" la tH>YEg1�q:Nrearrb.aul.e altomlaC"rUwearlO Dlsosa WaMe arMr�ecrrctl.web i.at IC.80 Al W07 acid 20ga. pro.rarMN, uNeYdM..s rrol.e tfp llafK oseDn values. W I C B O RRI160T erre RR.1.69 itbb., a slgnoae company R Cil T SPANS AS NDTEO O'M' fi, BNq D•. u0•T••IW +••W h• ' DIMENSION "C'• SPAN' Z 2.x4 2x6 411o"110! f.BA QI1: b�ItlMMIrD•FN11rV! W I•.M•I• h' Cbo `S rBrnM Y rf.f i ulPvi lbw a..qt•80TTOM w I.•■r f.grp • rirr 1•■raV r.erinwm.lw. ,+uwr •' t.1if rs r rrr PrpnuPr b a.r. YP a tTa M f H !1� • ♦ • ♦ • TOP CHORD - - * ! • • f • • 1 f MGRADE ».•I . 17'12 2 2 16 7 • .» .....QD.lr!2 6• 1 S 4 5 4 CN 27t 2u' 20• 3• 24 0• 27.10• 2 4• 1• S• r •WEB MEMBEUD GRADE Hn"7 I7 HEM -FIR CNi AS NOTED OK DESIGN Htr.FIR, Fill? ..f. rEtlt1ER.5 • blot #'E LIIp''Fi d 3DAN 'Y6 ANE O N S L 2 N4,0X4.S,T44 • . TO 24 0 OFF PANEL POIN SPLICE (T1) SPAN TO 24 0' SPACED 24.0 ■ P.C. 2X6 Ra.OXa,S,iaa -Tr) ta. 0• a,pi12 PITCH 2/2 COMFIG.URATjgN LL*DL ON POOP a 37.0 PSF DIMENSION "C'• SPAN' Z 2.x4 2x6 t 24, 0• OL ON CEILING 4 10.4 PSF • Z4210`113. 25" 3,25" 27t R2.4114.502.514 T`0. 16' 70 2Xt'R2.4X4.5,T2.S/4 TO 16' 7• TOTAL DESIGN LOAD • 4T.0 PSF • 4210"24S'J" 3.25•' 3.9" /'� A, ( • S PSF CEILING REDUCTION tAREN, AXIAL STRESS ONLY LOAD DURATION INCREASE a 1.15 ' 48'Q"t60'0" 3.9^ 4.5" 40.0"z70'0" 3.9• 5.8" v OPT d`/, x �/A/ (/ NAXTMUH TR1133 MEMBER FORCES REACTIONS 961 T 1 •1444 0 1 tJ70 w 1 92- r 2 •1459 ..: t R •0 a.i. 13T0 M' 3 •423 ASI- W,T-3/i.5 ' • PANEL POINT SPLIC3 (1J2) 2X6 R4.4Xb.QIT+3b TO 24, 0• c.PH�uN�[ Tit �3A-3j Y.00 p%4 ea.bxtr.0•TS4 t0 I41 7• .1 4f�t l R2..T1�,01Tt Si! To 2�• Q• � LD)N D PAR FMLi,: .. �y_ Iilt TJ2."co, (ftl.D �n) �./ V j� j AAATTyH T.C. _ ~d • 12in M41s fIJJ 14J'j1 2 FC *L PAMS 90TIUM $Zs4x1.'+�i-T2�.S�t• TO'26• O�`�.. , ,; t �•.^ .. •,. y -"h � - '►AMCL'►U211?..E�Li�E°(RJ?? _ f • 31"ltlti+_ P'i7iE;.i1R �a� " � . (f4i0%i.y114 ,[D $li! 0• R2.494.S- TO 24. 0•.R2�4itiw4 TO 24r 0* 42.A34•S. TO 19• J. to EPLIrf 110.4%3.O�T>11 T4 24' DOUG-iIR ' sPRUCE�IIAIE�FIR r T34 TO 241 0• T34 TO 240 0• .arra T2.S/4 TO 20. 90 T2.5/4 TO 19. 40 bf► t. Off PAWL POINT SPLICE (121 R34k4Xsloo-tZ•%/4 TO 240.:00 .. /K4 M0 fT�y�/�RC10�t iwf/lMrf•rQQDrl1466 QIMIAIIIi!•�•�Y••r1or.N ArgB �TR41R2{ #1R ,MaO1% QA11f -N.t/ 9f00R. tTt:<I �-IZII� f^MMMP•al'1xt�lllr•►+F:rw+sr+:r1bdh + Iftq w ws:,>!iry+t *.NllMMai. aYQrl soft>Ir•r+rw�•�IaAAQAn.►.wA►/14�11r..r. 'FBMrM1 MllF'Rl *flow tlt..t6'••AC w4l•AaM■�i114•1•lr�Yl,at=t.itw f4llall i+Y.rn rfrR•rslf�.M1Y.,A•iiplalal IIEf.: S•15�74 IOi4allrti( CK.411r"' Mw•+l1hP�'"aKT•11+hMN►wt.Qsur.wMt4wwir.QaMllrf!•w'rlrM1R .• ti11r11i7P'+•MYYr'fii►.IMyf441NArwwSQ4c • 14Y•.hArUAIU�.M�1lrplllft.•fpgBis. W4111111 .111" Mr rM "&" a lr tC.Rd N~ "now"a M w 0 mom ' � � �- 4 �Y 97i� �-..L •�. •y y'• -a a +� � � �. � � �. _ _ .fir . RESIDENTIAL ENERGY PLAN CHECK/INSPECTION SUMMARY Owner I% O / �p_s Climate Zone - & Floor Area Compliance path: T_a_Ckag6 ❑ A ❑ B ❑ C 2;ro int System MIN R -VALUE REQ'D Permit No. %d�? ❑ Budget ❑ Other DESCRIPTION INSTALLED ITEMS (1) INSULATION: Roof/Ceiling Wall ❑ Slab Floor Perimeter Raised Floor —/y` (2) INFILTRATION• ❑ (A) A vapor barrier is required in climate zones, 1, 14 & 16. ®' (B) All manufactured windows and sliding glass doors shall meet the 1972 ANSI Air Infiltration Standards and shall be certified and labeled. ® (C) All swinging doors and windows leading to unconditioned areas shall be fully weatherstripped. Tight - the above standard features plus: U7E COUNTY ❑ (D) Continuous infiltration barrier WILDING 13(E) Electrical outlet plate gasket CEPAR7-�'��.� 13(F) Air-to-air heat exchanger '� �� (3) GLAZING: '`-` �� (A) Location Area Glazing %Floor Area Single Double Triple ® Total Bldg Z ® North ® East / 6 South ® West Skylights..(B) Shading Shading Coefficient Description ❑ East ❑ South ❑ West ❑ Skylights 8 (C) South Overhang Length of projection _1„ft. Description ❑ (D) Moveable insulation: Area ftZ Description (E) Thermal mass ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft.Z HC= R= MC= Location ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft. HC= R= MC= Location 7/83 J '® 0 (4) MASONRY AND FACTORY -BUILT FIREPLACES shall be equipped with tight fitting closeable metal or glass doors covering the entire opening of the firebox; a combusion air intake equipped with a readily accessible, openable, and tight fitting damper to draw air from the. outside of the building; and a tight fitting flue damper with a readily accessible control. *1(5) HEATING, VENTILATING; AIR CONDITIONING SYSTEM (A). Heating Central Gas Furnace % (brand and model number) Btu/hr (heating capacity) Heat Pump. (brand and model number) Btu/hr (heating capacity at 47°F) Active Solar type (liquid or air) Collector brand and ft2 model number solar fraction collector area collector ACOP SE orientation collector tilt rated y -intercept rated slo Other 6aV/,Izsze (describe). (B) Cooling Electric Air Conditioner (brand and model number) Btu/hr (cooling capacity at 95°F) Electric Heat Pump (seasonal EER) EER Btu/hr (cooling capacity at 95°F) ❑ Other (describe) . { (C) A TWO-STAGE THERMOSTAT, which controls the supplementary heat on its second stage, shall be required for heat pumps. ❑ (D) AN AUTOMATIC SETBACK shall be provided for all thermostats, except those controlling heat pumps. ❑ (E) AN INTERMITTENT IGNITION DEVICE shall be provided for all gas-fired fan type central furnaces, gas-fired fan type wall furnaces and gas cooking appliances. (F) BACKDRAFT DAMPERS shall be provided for all fan systems exhausting air to the outside. (G) DUCT CONSTRUCTION & INSULATION.- A11 transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or mastic to prevent air loss and shall be insulated to conform to the provisions of Section 1005 of the UMC, 1976 Edition. 7/83 2 (D) FLOW RESTRICTORS shall be provided for.showerheads and faucets as outlined in the new appliance efficiency standards and shall be certified to the Energy Commission. (7) LIGHTING (A) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficacy of not less than 25 lumens per ,watt (usually florescent). xl Submit documentation of sizing heating and cooling equipment by Manual J, sizing charts (form #4) or other approved methods, section 2-5352(g), and fill out the following: 7 .Heating: Winter design temperature O °, elevation %(fid o ', heating load J,5 -,f BTU elevation factor x heating load = maximum outlet capacity gas,furnace BTU Cooling: Summer design temperature °, cooling load z7 %, BTU *2 Submit T.I.P.S.E. chart or other approved system (form #5) ��df�eryatA�i�s� GUIDE, solar panels. COOLING MAY E.E . EQUATE - ® DESIGN COMPLIANCE STATEMENT: The above building design meets the requirements of Title 24, Part 2, Chapter 2-53 of the California Administration Code. 7/83 SIGNAIr jOPBUILDING DE GNER OR APPLICANT 3 FO RK I (6) DOMESTIC WATER SYSTEM ❑ -(A) Gas Only ' Gallons (brand and model number) (tank size) ❑ Heat Pump w/Electric Backup (brand and model number) Gallons (tank size) * 2 Active Solar (collector brand and model number) (rated y -intercept) (rated slope) (solar fraction) ft :(backup heater type, brand and model number) (collector area) (collector orientation) (collector tilt) ❑ Location of Solar Panels ® Other (Describe) ® :(B) TANK INSULATION. Storage type water heaters and storage and backup tanks for solar systems shall be externally wrapped with R-12 insulation or greater. (C) PIPE INSULATION. The five feet'of pipe closest to the water heater and outside conditioned space shall be insulated with a minimum of R-3. Steam and -steam conditioned space shall be insulated with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water piping outside the building envelope shall be insulated in accordance with T20 -1408(d). (D) FLOW RESTRICTORS shall be provided for.showerheads and faucets as outlined in the new appliance efficiency standards and shall be certified to the Energy Commission. (7) LIGHTING (A) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficacy of not less than 25 lumens per ,watt (usually florescent). xl Submit documentation of sizing heating and cooling equipment by Manual J, sizing charts (form #4) or other approved methods, section 2-5352(g), and fill out the following: 7 .Heating: Winter design temperature O °, elevation %(fid o ', heating load J,5 -,f BTU elevation factor x heating load = maximum outlet capacity gas,furnace BTU Cooling: Summer design temperature °, cooling load z7 %, BTU *2 Submit T.I.P.S.E. chart or other approved system (form #5) ��df�eryatA�i�s� GUIDE, solar panels. COOLING MAY E.E . EQUATE - ® DESIGN COMPLIANCE STATEMENT: The above building design meets the requirements of Title 24, Part 2, Chapter 2-53 of the California Administration Code. 7/83 SIGNAIr jOPBUILDING DE GNER OR APPLICANT 3 L O� I7S Ft oo ✓2 �c� PSF C�tLr<<•1�� ►o X51oQ�pFESSIov Q coo l=- \N . 8q Fey c � Lj ` U No. 16803. CmL �F chu 11V JUN 261984 I ( 5._ M C�+x5 xpX I Z = 117 2 /50J PSI 0 X IZ D/_ •c'o. ( S� IZ�.2Z� /�� o ro oQROFESS/pfy,� LLJ `c U iVo. 16SU3, y _� �� ry n I t3 CIVIL ATF 0 a ti = SXSsIZ5-i� IZX/5C>� �� 1��4,,. 22 A/3 C. 2-5 3 itc� 2L 612-5-311L=.?,Opq .;..�., ...� . I TO O 73,c' P51 ©jam PROJECT: DRAWN: DATE.' SHEET NO. 2-Doey /V -,I -ens J 0114& 198 4- 13ACHMAN & ASSOCIATES CHECKED: JO® N0. 3012 Esplanade Chico, Ca. (916) 342-4136 I �� OFT d GLAZING PLAN TAKEOFF SHEET 3-5 North Glazing QUANTITY SIZE AREA' (SQ.FT.) (a) �_ x 6-2e 2_0 (b) x -11u is (d) _.�_ x 44030(d) _�_ n 3a (e) i x �oclo = & _ Total North Glazing = (SQ.FT.) (a+b+c+d— TOTAL c5'a 5a NORTH AL BLDG CONVERSION TOTAL % GLAZING FLOOR AREA FACTOR NORTH GLAZING 6 x 100 =��, % SQ.FT. SQ.FT. 3-7 South Glazing QUANTITY SIZE AREA (SQ.FT.) (a) _ x /oma, C2 _ (b) �_ x 4 ova = (c)_ x he yid = �- (d) _�_ x --s7w-0 _ IXo (e) _-�Lx�� .:Total South Glazing _ (SQ.FT.) (a+b+c+d+e ) TOTAL SOUTH . _' TOTAL BLDG, GLAZING FLOOR AREA, x w SQ'.FT. SQ.FT. :. CONVERSION TOTAL % FACTOR SOUTH GLAZING 100 3-9 Skylights QUANTITY SIZE AREA (SQ.FT.) (a) x�� (b) x = (c) x = Total Skylights L (SQ.FT.) (a+b+c) TOTAL SKYLIGHT TOTAL BLDG GLAZING FLOOR AREA _I -L- SQ.FT. SQ.FT. CONVERSION TOTAL FACTOR -SKYLIGHT GLAZING x 100 OWNER It It, lc 5 PERMIT NO. 7/83 --a FOR M 6 3-6 East Glazing QUANTITY ; SIZE AREA (SQ.FT:) (a) x ,2� e, -D' _-•-�� (b) x _ (c) x - (d) x = (e) x Total East Glazing.= (SQ.FT.) (a+b+c+d+e) TOTAL EAST TOTAL BLDG CONVERSION TOTAL % GLAZING FLOOR AREA FACTOR EAST GLAZING x. 100 SQ.FT. SQ.FT. 3-8 West Glazing QUANTITY SIZE AREA '(SQ.FT.) (a) -� x -S`7J c/.0 _ (b) x - (c) x =' (d) x s (e) x _ Total West Glazing = rc) (SQ.FT.) (a+b+c+d+e) TOTAL WEST TOTAL BLDG. CONVERSION TOTAL % GLAZING FLOOR AREA FACTOR ' WEST GLAZING x 100 SQ.FT. SQ':Vr. ZONE 11 ` OWNER JO : /"F _ /P POINTS PERMIT NO, ri.S3�'- tp ASSIGNED ACTUAL 1. SLAB - INSULATION NONE 2. RAISED FLOOR - R-19 3. CEILING - R-30 . 4. WALL - R-19 LE 5. NORTH GLAZING - 2.4-3.6% 6. EAST GLAZING - 2.5-3.6% 7. SOUTH GLAZING - 1.6-3.6% ` 8. WEST GLAZING - 2.9-3.6% 9. SKYLIGHT - 0-1.3% 10. SHADING (Exclude Overhang) • EAST - t j� .6.7-.82 �� _ SOUTH - 7,6 ;19-.42 WEST - :2, .13-.36 .SKYLIGHT - 1 .37-.57- 11. HORIZONTAL SOUTH OVERHANG 2'__ 12. MOVABLE INSULATION - NONE 13. INFILTRATION (Standard=0)(Tight=+12) -� 14. THERMAL MASS SF 15. GAS FURNACE (SE) 71-76% �--� - 16. HEAT PU11P (EER) 7.5-7.9% +3. 17. DUAL PACK (SE, SEER) 8.0-8.3/71-76% �- 13. ACTIVE SOLAR 60% IIIN (NONE) - ^' 19. ZONALLY CONTROLLED ELECTRIC '�- 2,0. SOLAR WITH 0" BACKUP (HW) �^ 21. OTHER - 1*-ELECTP,IC (HW) 6 Table 3-1. Slab Floor P 17naula- I R -Value of I' 1 tt�T�-r 10epch, "hh i lnchea 0-2 1 3-4 I 1:j 1- . TE� kTN ZERO POTNTe}" - Tab1•e'3-2.fRa1sed Floor Pointa ' 5-6 1' 7+ I'0 -111-s 1is" I-5 I-5 I 12 - 15 ( -5 I -7-2 1 -1 116-191-5 i-2 I1 0 I 20 + 1 -S I -1 1 0 +1 7/7/83 a-vaiue or Insulation below 3 3 - 4 S-7 8 - 12 17 - 18 •19+ Table 3-3a. Ceiling Insulation Points of Insulation I Points 19 1 -4 22 1 -2 49 i +4 R -Value of Insulation I Pointe 19 I 0 24 1 +2- 30 1 +3 Table 3-5. North -Facing Glazing Pti i I I Glazing Type I Total I I 2 of Sngl, I Db ITrpl,1 I Floor l u I U, I U- I I Area ( 0.66 ! 0.42- ! 0.41 I I ! 1.10 10.65 I down I O 1 +4 +4 +4 ( 0.1- 1.2 I +4 ! +6 ! 1.3- 2.3 I +1 I +2 I +2 ! I 2.4- 3.6 I -2 I 0 1 +1 I 3.1- 4.8 I -4I -2 I -1 I -3 I I 6.2- 7.3 I -9 I -6 I -5 I I 7.4- 8.2 i -12 I -8 I -7 I ! 8.3- 9.7 .I -14 I -10 ! -8 ! 1 9.8-10.8 I -17 I -12 I -10 I ! 10.9-12.0 I -19 I -14 ( -12 I 112.1-13.2 I -22 I -16 I -13 1 113.3-14.5 I -24 I -18 I -15 I 14.6-15.3 i -27 i -20 1 -17 Table 3-6. East -Facing Glazing Pts. Table 3-7. South -Facing Glazing Pte Table 3-10. Shading Coefficient Points i I I . 1 Glazing Type I I SC by I I .1 11.6 13.2 1 2.5- 3.6 1 16.4 19.0 1 • Total I ! I Orien- ! S Floor Area i to I to I to I 2 of ( Sngl, Dbl, Trpl, I tation I I -6 11.5 1 3.1 16.3 I 6.8- 7.7 I i 7.9 I Floor I (U - I (U - I (U - I I I 1 -10 1 -8 'I I i 8.8- 9.7 1 -1.7 1 I Area 11.10) 10.65) ( 0.41)1 1. +3 I .-1S I -13 ; 111.3-12.7 1 -25 i I I oints I ointsI ointsl I East 1 0-3.1 I 3.2 I to 6.4 up +3 I +6 I I up o 1.5 ! 2 I +2 I +2 ! I 0 1 1 6.3 1 0 1 0 I 1.6- 3.6 I -1 I 0 I 0 1 1 I I I I 0 I -1 I I 3.7- 5.2 I -4 I -2 I -2 I I -10 I -6 ! -4 .58-.82I -1 I 5.3- 6.5 I -6 I -4 I -3 I I 0 -.19 1 0 I +1 ( +2 •8'- up -2 I -o I-^ ) -5 I I .20-.36 I 0 1 0 I -1 -7 1 7.8- 8.9 I -11 I -8 1 -7 I I .37-4M 1 0 1 -0 I 0 I -12 I I 9.0-10.0 I -13 I -10 .I -9 I I .67-. 1 0 I 0 I -1 -20 110.1-11.5 I -17 I -13 I -11 I I .83 up I 0 I -1 1 -2 1 8.3- 8.8 1 111.6-13.0 I -21 I -16 I -14 1 1 to I I to I to I too to 113.1-14.5 I -25 i -19 I -16 -15 I I .7 ! I ! ( 1 14.6-16.0 I -28 I -22 I -'.9 I I South 1 0 1 3.2 16.4 ! 8.0 19.6 I I I I ► I I 0 -.18 I .19-.42 I to I 13.1 16.3 1 0 1 1 0 1 to +1 O I' to I 17.9 ! I +2 I I to I 9.5 +2 ! up +3 Table 3-8. West -Facing Glazing Pts, 1 I Glazing type 11 T I Total Tof I -35 I .43-.66 0 - 0 1 - 0 1 ! 0 -3 I I Sngl, Dbl, Trpl,l .67 up 0 -2 I -0 I T2 -4 I -6 I Floor I (U - I (U - I (U - I 112.8-13.5 I -42 I -32 I -27 ! •58-•82 I -1 I -3 I -6 I -12 1 -. 113.6-14.3 i -46 I Area ( 1.10) 10.65) 1 0.41)1 I !points I oints I ointsl West I .1 11.6 13.2 1 2.5- 3.6 1 16.4 19.0 O 1 +6 1 +6 1 +6 1 1 -2 to i to I to I to I up I up to 1.3 I +5 I +6 ! +6 I I -6 11.5 1 3.1 16.3 I 6.8- 7.7 I i 7.9 I I 1.4- 2.2 I +3 i +4 I +5 1 -10 1 -8 'I I i 8.8- 9.7 1 -1.7 1 -12 1 1 2.3- 2.8I 0 1 +2 I +3 I .-1S I -13 ; 111.3-12.7 1 -25 i -18 I i-r_T=!-3 ( 0 I +1 I 0-.12 1 0 I +1 I +3 I +6 I +7 I 3.7- 4.2 I -5 I -2 i 0 1 .13-•36 i 0 1 0 1 0 1 0 1 0 1 4.3- 5.0 I -8 I -4 ! -2 ! .37-.57 I 0 I -1 I -3 I -6 I -7 I 5.1- 5.6 I -10 I -6 ! -4 .58-.82I -1 I -3 I .-6 ! -12 1 -15 I 5.7- 6.2 ! -13 I -8 I -6 1 •8'- up -2 - I -8 I -16 I -.70 i 6.3- 6.9 I -I5 I -10 i -7 I 7.0- 7.6 I -18 I -12 I -9 I 1 7.7- 8.2 I -20 I -14 I -11 I Skylight .8 1 8.3- 8.8 1 -22 I -16 I -13 I to 11.6 to 1 t to to I to I too to i 8.9- 9.5 I -25 I -18 I -15 I I .7 ! I ! ( 5.2 I 9.6-10.1 I -27 -20 I -16 I 110.2-11.0 ! -29 I -23 I -17 ! 0-.12 I 0 I +1 I +3 ! +6 I +7 111.1-11.8 1 -35 I -26 I -21 I •13-.36 1 0 1 0 1 0 1 0 1 0 111.9-12.7 1 -38 I -29 I -24' ! •37-.57 I 0 ! -1 I -3 I -6 ! -- 112.8-13.5 I -42 I -32 I -27 ! •58-•82 I -1 I -3 I -6 I -12 1 -. 113.6-14.3 i -46 ! -35 I -29 I 83 up - i -4 i -8 i -16 i -20 1 14.4-15.2 1 -50 ! -38 1 -32 I I i I I I I Table 3-11. Horizontal South Overhane Pointe Table 3-9. Skylight Points 1 South Glazing T _TI Length Out I Area, 2 of Floor I I i Glazing Type I I from Wall I I I I Glazing Type I I Total I I I ft T_ Total 2 of Floor Area I I 2 ofSngl, Dbl, Trpl, I 1 0-6.3 I 6:4 up I Sngl, Dbl, Trpl, I Floor (U - I (U - I (U - I I Area 1.10) 1 0.65).1 0.41)1 1 o:nts IDoints loointal T - Pointe I ! --r I O 1 1 un to 1.3 1 44 +3 1 44 I r 1 +4 1 I t47- I +2 I I 1.6- 2.4 I tl . I +2 -12 ( 1 2.5- 3.6 1 -2 I 0 1 0 1 -8 1 1 3.7- 4.6 ( -5 1 -2 1 -1 1 -6 I I 4.7- 3.6 I -8 I -4 I -3 I -4' I I 5.7- 6.7 I -10 I -6 I -3 I +2 I I 6.8- 7.7 I -13 I -8 I -7 0 I I 7.8- 8.7 I -15 1 -10 1 -8 'I I i 8.8- 9.7 1 -1.7 1 -12 1 -10 1 i 9.8-11.2 I -21 I .-1S I -13 ; 111.3-12.7 1 -25 i -18 I -15 1 ( 12.8-14.0 I -28 -21 I -18 I •I. 1 14.1-15.3 I _) -32 1 -24 I -20 I 1 +4-2 2 I 2.3- 2.8 ( 2.9- 3.6 I 3.7- 4.2 I 4.3- 5.0 I 5.1- 5.6 I 5.7- 6.2 I 6.3- 6.9 I 7.0- 7.6 I 7.7- 8.2 I 8.3- 8.8 8.9- 9.5 9.6-10.1 lU- lu- l0 -I 10.66- 10.42- 10.41 i 1 1.10 10.65 I down I I -10L 0 I -3 1 1 -1 I 11.6 - 17.5 1 +4 17.6 - 23.3 I I I s I s l -6 I -14 I -10 I -8 I I -16 I -12 I -10 I 1 -21 I -16 I -13 1 1 -24 I -19 I -15 -26 I -20 I -17 I -28 1 -22 I -19 I I -31 I -24 I -21 I -33 I -26 I -22 I � �- ii• 7 1 -L I -� I 10.6 - 1.0 I -2 1 -3 I 11.1 - 1:9 1 -1 I -f I ! 2.0 up I 0 I 0 I I I I I Table 3-12. Movable Insulation Points I Moveable Insulation] I Area, S of Floor ! Points I 0 - 5.5 I 0 5.6 - 11.5 I +2 11.6 - 17.5 1 +4 17.6 - 23.3 I +6 >23.6+ I +8 b. Table 3-13. Iaffltration Control Features Points r -- 1 I Control Features 1 Points 1 I 1 1 I Standard I 0 I I I I 19.9 air changes per hr ( I I I t Tight 0.6 air changes per hr Table 3-15. Cas Furnace Without Refrigeration Cool!c.e Points I Seasonal Efficiency 1 Polots I I (-E), I I Energy Effic!ency I 71 - 76 I 0 1 I 77 - 82 I +2 I I 83 - 88 I +4 I a9 - 94 ) +6 I 95 up i +8 I 8.4 - 8.7 Table 3-16. Neat Puma Points I Energy Effic!ency 1 Ports 1 I Patio (EER) 1 I I 7.5 - 7.9 I +3 i I I 8.0 - 8.3 I +6 I I 8.4 - 8.7 I +9 I I 8.8 - 9.1 I +12 I I 9.2 - 9.6 I +13 I I 9.7 - 10.2 1 +18 I I 10.3 - 10.8 1 +21 1 I 10.9 - 11.5 I +24 I I 11.6 - 12.3 I +27 1 12.4 - I 13.2 1 +30 1 I I Table 3-17. Cas Furnace With I__ Refrigeration Cooling Points 1Refelgerationl Gas Furnace I I Cooling I SE ; • I 1- 7- dl- 89- 95 I 1 761 821 881.94" u I r 1 8.0 - 8.3 1 01 +21 +41 +61 +8 1 1 8.4 - 8.7 1 +21 +41 +61 +91+10 1 1 8.3 - 9.2,1 +41 +61 +81+101+12 1 1 9.: - 9.7 1 +61 +81+101+12.1+14 1 I 9.8 - 10.3 1 +31+1x1+121+141+16 1 110.4 - 10.9 1+1G1+L2i+141+161+18 I 1 11.0 - 11.6 1+121+141+161+'181+20 1 I I ! 1 I I 7/7/83 ZONE 11 . TABLE 3-11 (6DAI7E0) ERTER,IOR THERMAL MASS POINTS MASS DWELLING ARFA SQUARE FOOT AREA 1,000 1.500 21000 2,S0o I 3,000 3,500 4,000 I 4,500 5_,000 i SQ. FT. t Aj 8 C D A 8 C 0 A 8 C D A 8 C D A B C 0 A 8 C D A 8 C 0 A B 8 C So 2 2 2 2 2 2 2 01 2 2 2 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 0' p. a 0 p 10o. 4 4 4 2 2 2 2 2 2 2 2 2 2 2 2 0 2 2 2 0 2 2 0 0 2 2 0 0 2 2 0 0� 0 0 0 0 ISO 6- 6 6 4 4 4 4 2 2- '2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 2. 2 2' 0 2 2 2 0 i 200 8 8 6 4 6 6 4 2 4 4 a 2 4 4 2. 2 2 2 2 2 2 .2 2 2 2 2 2 2 2 2 2 2 Z' . 2 0 1 259 10 10 8 6 6 6 6 4 6 6 4 2 4 4 4 2 4 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2- 300 12 12 10 6 8 B 6 16 6 6 4 6 6 4 2 4 4 4 2 4.4 2 2 2 2 2 7. 2 2 2 7 2.2 2 2 I 350 14 14 12 8 10 IG 8 6 6 6 6 4 6 6 6 2 6 4 4 2 4 4 4 2 4 4 2 2 4 4 2 7 2 2 2 2 400 14 14 12 8 10 10 8 6 8 8 6 4 6 6 4 4 6 - 6 4 2 4 4 4 2 4 1 1 2 4 4 2 2 3 4 2 2 800 18 18 16 10 12 12 10 6 10 10 8 6 R 8 6 0 6 6 6 / 6 6 6 2 6 6 4 2 4 < 4 2 1 < 4 li 600 22 20 IB 12 14 14 12 8 12 12 10 6 10 10 8 6 8 8 6 4 8 6 6 4 6 6 6 4 66. 4 2 6 6 4 2 • I 709 24 24 20 14 18 16 111 10 14 14 12 8 10 10 10 6 10 10 8 6 8 B 6 4 8 6. 6 4 6 A 6 41 6 6 6 7. ; 230 26 24 22 16 70 16 16 10 14 14 12 8 12 10 10 6 10 10 8 6 10 R 8 4 I e 6 6 4 8 6 64� 6 6 6 s i 900 28 28 74 16 22 20 IB 12 16 16 14 10 14 it 12 8 12 12 10 6 10 10 9 6 13 8 '8 a 8 8 6 4, B 8 6 e ; 1,000 30 l0 25 18 Y2 20 20 14 18 18 1610 14 14 12 8 12 17. 10 6 12 10 10 6 10 10 8 6 8 8 0 4j n 8 6 4 i 1.700 32 32 28 20 24 24 22 14 20 20 18 10 16 16 14 8 14 14 121 8 12 12 1010 10 10 6 lO 10 8 C. 10 e e 1,200 34 32 30 22 26 26 22 16 22 20 18 12 18 18 14 10 14 14 12 8 14 12 12 8 f'12 12 10 6 10 10 8 6I In in 8 6 1.300 34 34 32 22 28 26 24 16 22 22 20 12 18 18 lE 10 U14 14 8 14 12 12 6 112 12 10 6 12 10 10 6� 10 70 F. 6 1,100 34 '34 32 24 28 28 26 18 24 24 20 14 120 20 18 12 t8 16 14 10 14 14 12 8 14 14 12 8 12 1' :G 6; 20 19 17 S I I,iva J6 34 34 24 30 30 26 18 24 24 22 14 22 20 18 12 18 18 16 10 I 16 16 14 8 14 14 12 N 17 1: 10 GI 72 12 1;. o i 2,900 34 34 32 22 30 30 26 18 26 26 22 16 22 22 20 14 120 20 t8 12 t8 18 16 10 16 16 is LI 14 14 12 8 i 2.500 34 34 30 22 30 30 26 18 26 26 24 16 24 24 22. 14 22 22 18 :2 20 20 18 !.•1 ly 1s 16 :0 3.-.00 34 32 30 22 30 30 26 18 28 "6 24 16 (24 24 22 14 22 22 20 1411 :7 :J 3n It 3,50032 32 30 20 30 30 26 18 78 28 24 16 26 24 22 14 ! -.4 ;4 20 14 4,990 32 32 30 20 ! 30 30 26 IS i 79 28 24 if 25 2a 2: le -4,500 132 32 28 20 130 3J 26 ;1' 1 iti in3= :E s_003 72 17 2e 231 IJ 3u .6 1d A) 1. 3's" Concrete Slab: HC -8.93; R-.29; Factor -7.3 4-a-0 2. 3 3/4" Thick Common Brick: IIC-7.125; R-.13; Factor -7.3 Ta -0 8) 1. 54• Concrete Slab: RC•14.106; x'.•.458; F'octor•7.1 wood stove C 1. B" Solid Filled Block: HC•20.63; R -1.9J; Factor -6.1 113'points no-bark-t,p) 2. 8` Solid F11ted Bloci With Both Sides Exposed To Conditioned Air. ca.sablanca fan + 1 point NOTE: Use all square footage directly exposed to conditioned air for Thermal"Mass Area: IIC-10.164; R-.9b�; Factor -6.1 D) i" Thick Concrete/TIT e: HC -2.55; R-.083; Factor -3.1 Table 3-19. Zonally Controlled Electric Resistance Space Heating Points ' Points foethis measure v!1^1 Table 3-20. Solar Water Heatin With Cas Bscku Paints , I be completed after the CEC 1 1 has approved an Alternative I I Component Package for Resistance I I Beat. I Table 3-18. Active Solar Space Heating with Gas Points I Net Solar Fraction I (NSF), % I 0-6 1 0 1 I 7 - 14 I +2 I I 15 - 23 1 +4 I I 24 - 30 I +6 1 I 31 - 39 I +8 I I 40 - 47 I : +10 I I 48 - 55 I 4.12 I I _ 56 - 6] 1 +14 I I 64 - 71 I +18 I' I 72 up I • +20 1 I: 50-59 60-69 t"•ultifamll (er unitpoints) Floor Area Net Solar Fraction (NSF). Z per unit, ft2. 0.9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 , 600-799 0 +3 +7 +10 +14 +17 +21 +24 800-999 0 +3 +5 +8 +11 +14 +16 +19 1,000-1,499 0 +2 +4 +6 +8 +10 +12 +14 1,500-1.999 0 +1 +3 +4 +6 +7 +8 +10 2X00 and up 0' 1 +1 +2 +4 +5 +6 1 +7 1 +9 All others (pe build ng points) 8U0-899 0 +5 +10 +14 +19 +24 +_9 -+3C- 900-999 0 +4 +9 +13 +17 +il +26 +30 1,0Oo-•1-,199 0 +4 +l +11 +15 +19 +22 +26 1.2k,1,499 0 +3 +6 +9 +12 +I5 +18 +21 1,500-1,999 0 +2 +5 +7 +9 +12 +14 +le 1,1)40-2,999 0 +2 +3 +5 +7 +8 +10 +11 3,060 ir.d uo 0 +1 +3 +4 +5 +•7 +S +10 u I Table 3-21. Other Water I!eatlnq Pts. I System Type I Points I COnl;� I 0 i I 1 Heat Pump I 0 ) I Solar with Electric I I I Resistance0ackup I - 1 I Muting the Require- ( I ments its Part 'a i 0 I Electric Resistance Daly -40 ;