Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
021-220-032
021-220-017 LAND DEVELOPMENT SHU N1 021-220-0X PER,141T#96-1230 JUSTESON, Ford 475 Block Rd., Gridley Cont: Scott Walker /�/�� New Single Family 1307-038 021-220-032 MISCELLANEOUS Ag Exempt AG BLDG - FOR AQUATIC FARMING, 475 BLOCK ROAD JUSTESON/FORD L P, BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES AGRICULTURAL BUILDING EXEMPTION PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 WEBSITE: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 475 BLOCK ROAD Owner: Permit No: B07-1538 APN: 021-220-032 JUSTESON/FORD L P, Issued Date: 08/14/2007 By KCG Permit type: MISCELLANEOUS 475 BLOCK RD Subtype: Ag Exempt GRIDLEY, CA 95948 Expiration Date: 08/13/2008 Description: AG BLDG - FOR AQUATIC FARML (530) 846-3788 Occupancy: U-3 Zoning: A-40 Contractor Applicant: Square Footage: JUSTESON/FORD L P, JUSTESON/FORD L P, Building Garage Remdl/Addn 475 BLOCK RD 475 BLOCK RD GRIDLEY, CA 95948 GRIDLEY, CA 95948 Other Porch/Patio Total (530) 846-3788 (530) 846-3788 FEE INFORMATION DBEH Building Review Fee $75.70 DBOMSCF Ag Exemption Permit $115.98 Total Charged: $191.68 Fees Paid: $191.68 Balance Due: $0.00 Receipt No: B3904 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License JUSTESON/FORD L P, OL:CRW_00355046 / / Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, , also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) is in full force and effect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the X basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]; 08/14/2007 Please check one of the following: Contractor's Signature Date I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE La COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE iSec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of the property, who builds or improves thereon, and who does WORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: HAVE the work himself or herself or through his or her own employees, provided that such improvements ❑I AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by ❑❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Provessions Code: Section 3700 of the Labor Cade, for the performance of the work for which this permit is issued. The Contractor's Licerue Law dows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractor's License Law.). Carrier: Policy Number: Exp. Date: (This section need not a completed if the permit is for one hundred dollars ($100) or less. ❑ I AM EXEMPT under Section B. & P.C. for this reason: ®I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California, and agree that if I should become subject to the workers' - 08/14/2007 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Owner's Sig re 1 Date i X 08/14/2007 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building D Signature Date WARNING: FAIL VIE SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, WARNING: FAIL VIE TO SECURE WORKERS'COMPENSATION COVERAGE IS UNLAWFUL,Butte construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, injury, including death, and property damage caused by, arising out of, or in any way connected with the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND ATTORNEY'S FEES. use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte County to enter the above mentioned property for inspection purposes. I hereby certify that I am the property owner or am authorized to act on the property owner's behalf. � 56 � CONSTRUCTION LENDING AGENCY p d, 68/14/2007 I HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name of rmitte IGNI Print Date the performance of the work for which this permit is issued. (3097 civ, code) ® Owner 0 Contractor OR; DAgent for Owner Agent for Contractor FILE COPY Lender's Address City State Zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 WEBSITE: www.buttecounty.net/dds AGRICULTURAL BUILDING EXEMPTION STATEMENT Agricultural building is defined as follows: Agricultural building is a structure designed and constructed to house farm implements, hay, grain, poultry, livestock, or other horticultural products. This structure shall not be a place of human habitation or aplace of employment where agricultural products are processed, treated or packaged, nor shall it be a place used by the public. Buildings used for purposes other than described above or that are located in a flood hazard zone are not eligible for an agricultural exemption. Authorization of an agricultural exemption permit by the Department of Development Services does not preclude any requirements and/or review by the Butte County Public Works Department, Butte County Fire Department, Butte County Environmental Health, or any state and federal agencies. Initials AG Buildings shall be a minimum of five (5) feet from any septic tank or leach fields. Initials AG Buildings less than 1000 sq. ft. in floor area shall be located a minimum of 6 feet from a residence, 10 feet from a manufactured home, and 23 feet from a commercial/industrial buildings Initials������ //�� AG Buildings greater than 1000 sq. ft. in floor area shall be located a minimum 23 feet from a _V41 residence and a manufactured home, and 40 feet from a commercial/industrial buildings Site Address: 475 BLOCK ROAD Permit No: B07-1538 APN: 021-220-032 Square Footage: Permit Type: MISCELLANEOUS Occupancy: U-3 Permit Subtype: Ag Exempt Zoning: A-40 Description: AG BLDG - FOR AQUATIC FARMING/FISI Required Setbacks: Applicant: JUSTESON/FORD L P, Front: Side: 25' Rear: 25' 475 BLOCK RD GRIDLEYCA95948 Type of Construction: (530) 846-3788 Type of Siding: T-111 Owner: JUSTESON/FORD L P, Est. Const. Cost: $ 7,000.00 475 BLOCK RD GRIDLEY, CA 95948 Roof Covering: Compostion (530) 846-3788 Floor Type: Concrete I declare under penalty of perjury that the building will be used as stated above, and the proposed use conforms with the AG Building definition. If any change in use or occupancy of the building is made, I will contact the Building Division and obtain the necessary permits, inspections and approvals to comply with the requirements in effect at that time and prior to occupancy. Signature of owner:��f%--/, " , !!! �'2 0" "Z'-- 9 Date: 07/16/2007 FILE COPY BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds **PLEASE PRINT CLEARLY** APPLICANT INFORMATION OWNER INFORMATION Last Name v t, First Name 1-4 Mailing Address ! City State C Zip 5� y Pho e3 ^ E-mail - Fax APPLICANT INFORMATION CONTRACTOR Name v t, Address Zi _ � City Fax State Zip Phone Fax E-mail Lic. # Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name Av s� Address Zi _ � City Fax State Zip Phone Fax E-mail State License Number APPLICANT INFORMATION Name .k5 t�S(5'.,< Addres 7 0 /' 1Z� ` StattA Zi _ � kgs b.�Cu��iT Fax E-mail APPLICANT SIGNATURE X ; )Aj Al PERMIT NO. o-�[63� BIN # PROJECT LOCATION AP# - 2 - Property A dress City , ' c WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: 13 w Cd(s .)-C—o rt (3 %A vii i S No X3 Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office'use only: Zoning j FI od Zone SRA I Yes I No Occ. Type Const. $u•l��n��m� 115. q� 7`I41.Co$ hers due xRESIDENTIAL 021-220-017 ' PERMIT#96-1230 JUSTESON, Ford 475 Block Rd., Gridley Cont: Scott'Walker New Single Family OFFICE COPY FGAS Date f JOB, FINALED (Date — 'Signature t V=OK O = Not OK = Not Applicable C =Not Ready .I. MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements - Setbacks - Easements 1 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Gmd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap; / PL'ft. / /Nat. or/ PL"ft./ /LPG v - 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date 'Card B-1 Date - - Card B-1 Date Card B -1.t, Date MOBILE HOME INSTALLATION (Plans) OK except #'s. 1. Zoning Requirements -Setbacks Easements 2. Footings; SizeSpacing-Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances r� 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except Fs, - 1. 's,1. Zoning Requirements -Setbacks -Easements \1 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3: Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails -�t 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg: Rfg: Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures I 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rttrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s r 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/6 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 v - r r -7- =K plicable = Not Ready RESIDENTIAL (Single Date E LOOR (Plans) OK except ft's Date 1 oning-Setbacks-Easements-Flood-Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth -----' q_.Ztg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 17��7IT ✓ �._Ftg., Porches & Decks; Soils -Steel `/,�g_ Depth& s 5- V-'5. walls, Main; Steel -Bloc kouts4lirapped t/f%_StemWalls, Garage; Steel-Blockouts-Wrapped 1��16a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. * s -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts: Clearance -Material -Support -Ins. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Access & Ventilation ns Iation Date and B-7 Date Card B-1 Date and B-1 Date Card B-1 Date PLU BING (Permit) Prexcept n's Water Htr.: Vent -Access -Combustion Air -Baffle ----- - W Pipe: Test & Anchor -N 'I Protection D st-Fit�rfi s & A or -Nail Pf, `tion ------------------------------------------- - - hower Pan: Test. First Floor -Tub Access ----- --- & Shower, Second Floor -Tub Access -- ------ - - - --------------------- --------- ------- -- ------ G ', Pipe: Size & Anchors ----- ----- ------------------------------------------------------------ Date ��$-� Card --- Date 0-- Card B-1 Date -tj(p Card B-1 VF Date Card B-1 Date ELECTRICAL (Permit) OK except a's 22. fixture &Transformer Clearance -Ins. Protection ----------EI . eceptacles Spacing -Lights & Switches at Doors Size Boxes & No. of Cond_ uct_ors-Stapled ��e ex Installed Close to Ed of Studs & E uip Ground made 'Mech. Fasiners and ----- ----------------- --- pplianCircuts in Kitchen & Conductor Size,GFI -. Subfeed Wire Size I Zga. Cu o A.C- Wire S ze ga. --------- - -- - Ra a Circ. i� ga. Cu or AI -Oven Circ. ga. Cu 0(9 sulated Neutral ❑ Yes fl No - - --�r --- Service -Riser Conductors & Ground -Main Disconnect y� 31. Equip_ Clearances Panels.Motors-Mech. Equip. / 32 hes Closet Light -Shower Light -Spa Light :i6 Smoke Detector --------- - Date /$� Card B-1 Date Card B-1 - ---- - ....... - ------------------- ... ... ... ... .. Date 1p-ciF` - Card B-1 Date Card B-1 Date MECHA CAL,(Permit) OK except f+'s Ccis Insulation & Support --------------- ... -- --- - - .......-----....... .. 3 ent Fan: Exhaust above insulation Condensate Drain & Overflow: Size & Grade rn nce-Vent: Access -Comb. Air -Return Air Vent -115 outlet ----- ----- 3 Attic Access & Platform if Furnance in Attic DaIe ------ Card B-1 Date Card B-1 Date jO- fo-R4 Card B-1 1`� Date Card B-1 Date FRAM( (Plans) OK except fr's ils. Proper Material & Anchors -- - --- - alls Studs -Nailing. Spacing & Bracing -Plates -Sound 4ng Walls over Girders &Floor Nailing I, aft Stop in Walls (rat proof) Fire'.tops_.Furred Ceilings -Stairs -Chases -Tub 'T Headers & Beam -S ze & Bearing & Duplex) ING (Continued ngers-PostCaps-Anchors-Connectors rg,. Joist -R r. ties-Purlin-roof Brac-Truss-Shthng.-Rfr 'place TZ or Type A Flue -Fireplace Throat clearance �cess; Size & Romex Protection -Draft Ste -In�. r mdows or Exiting Doors -Sill Hgt. & Dimensions` rage Fire Protection Framing 54--Pr5per4y_Une Firewall & Openings ---------------------------------- — - xt. Doors -One 3' -Check Garage -3rd Story, 2 Exits ---- ------------------- --------------------- 53. _Stairs: Width -Headroom -Rise -Run -Landing -Fire Protection ywood on Roof Overhang -Attic Vents -Rafter Outriggers ........... 5t i g- Nailing Veneer �� Mesh -Drip Screed -Fd. Vents- Underf�cess la g Area -Glass Protection -Skylights -Plastic -------- ---.--hear Walls: Nailing -Bolls 59.- 1p Insulation-dtis-Ceilings -- ----------------- nfiltration-Walls-Windows Date (/ �f� and B-1 /Z Date Card B-1 Date U `to -y/Card B-1 r7 Date Card B-1 Date FINAL (plans) OK except a's xt. Steps -Door & Sidelight Protection -Landings —_ ----- - -. - moke Detector----- — - -------------------- r.—mace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor-Ducts-Mech. Protection f!4!B- d—om Exiting ------------ -- --- *.Ile - --- B-------------------- .I. & ath Fixtures &-Tub Access -Spa --------------- --- yye�c. Trim & Subpanel: Breaker Sizes & Labels 6n Stairs & Rails ------------- --.�'replace or Stove: Clearances -Hearth - ---- - --------------------- ft+. _.. --------------------------- .._.. ec_ Outlets at Wood Panel_ Int_ & Ext_--- Z9_- -T1xt. & Appliance: Grnd_ Air Gap -Cooking Clearance — ----- - -- 7 ec Outlets & Receptacles at Kit. Counter _ 72�. Garage Fire Door Swing -Landing -Closer — 7!3!A.C. Duct in Garage -Damper — 7� Htr.: Vents -Clearance -Comb Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection -- 7 Elec. &Mech. Equip. Listed for Location 7 c. Receptacles in Garage: (G.F.I.)-Romexmex Protection sulation -Foam-Looked in Attic ❑ Yes 7 uard Rails & Deck Construction -Post Caps .-- ------- - ---------------------------------- L9,411n. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes__ 80. Fonowmg in9d� Drive ems ❑ No: Walks ❑Yes OF No; Planters ❑ Yes ❑ No ----------------------------------------------- — ----------- -da—SMCT(5 Brown -Finish . .. . .. - ---- ------------- —--- --------------- i12�A C Unit: D, sconnect. Electrical. Plumbing . ... ...--------------------------- -- ----- d nts Above Roof: Plbg.-Appliance-Fireplace.-Clearance to Ope angs------------ 8 ater Well: Disconnect. Electrical. Plumbing 8 tenor Elec. Tnm: G F. 1. Receptacle -Underground ..------ ----------------- ----------------- iee n ,Iation Throughout House . .._. ..-- --------------------------------- - -------------------------------ss Protection 8.g.; ✓oq�ctionsfrom Previous Inspections A as Tes Metets Tagged. Gas---------------------------------------ElectriC 401-�at ewer Connected -C/O to Grade HD Approval ... __--- - -------- ------------------------- nergy Comphance Certif cafe -Other Certificates _-t- -- --------------------- Date f/J/!/� Card B 1 Date ------------- Card B 1--- Date / Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final Y 9166852831 OCT -08-1996; 15:04 WESTERN BUYERS DC , 9166852831 P.06 AMAJO Anpw.v=PIN �; Certificate ofe Conformance Certificate 0 5 n7 6 5 THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural woodr identified below and marked with a collective mark of Engineered Wood Systems (EiWS) were uarl. ufactured in accordance with the specifications indicated below. K11 ANSI Standard A1g0.1-1992, for Structural Glued Laminated Timber 0 Job Name Jobtomilon ELK GROVE, CALIFORNIA _�.; cuemames order No. W8-80045 Data 6-24-96 Mfgr's order fVa. 09-04385 INDIVIDUAL WRAP, ENDS 8 SIDES SEALED,CAMBER 2000' RADIUS. 81gral4are _ C� ,� __rine QUALITY C NTRO _VffRrrcnn C,0,,,A, 8015E CASCADE CORP.Address P - 0 • Box 50 02 �19G Dace BOISE, -IDAHO 83728 IT IS HEREBY CERTIFIED that the structural glued laminated timber production of the above-named manufacturer which carries a collective mark of Engineered Wood Systems (EWS) is subject to regular audit by Engineered Wood Systems, such audit consisting of the Inspection with reasonable frequency of the manufacturing process, with adequate sampling to verify the quality of glulam construction and the adequacy of glue bond. by Thomas G. Williamson ' Executive Vice President MOINEERED WooD SYSTEMS -A RW ATEn #' MRVrWbAv .-....v .... ' TOTAL P.06 9166852831 OCT -08-1996 15:04 WESTERN BUYERS DC 9166852831 P.05 APAMao Al � ent Number 1 -too cumFICAT� OF CONFORMANCE NQ 050765 DATED WESTERN BUYERS INC. Job Nem® 7� /3�c l / �� �� 1� VE, CALIFORNIA J110, ob Ltien c/ 09-04385 WB -80045 Dated 5-24-95 Mtgr's Order No. Customers order No. following identifies the members and gives the basic specifications that were used on this job: The fol 9 DOUGLAS FIR/LARCH Lumber Species: Adhesive Appearance Member Size Combination Type grade Camber n„antHv WSMUMUOR *** SEE ATTACHED ORDER ACKNOWLEDGMENT FOR EXACT -SPECIFICATIONS. *'�* B )ISE CASCADE ORPOR Bo Company WWII MOW ontrol gupenisor Date W000 SYSTEMS — A RELPM cORPORAnON OF AMERICAN PLYWOOD ASSOCtMION AMERICAN 9166852831 OCT -08-1996 15:02 WESTERN BUYERS DC ENGINEERED WOOD SYSTEMS - 6 Attachment Number 2 9166852831 P.02 TO CERTIFICATE OF CONFORMANCE NO 050765 DATED 6-24-96 Job Name WESTERN BUYERS INC. G` d r 0 --_ {'.r, r •r ,lobt.600an /310cA(_ ___/c/�>,. - 6 , CALIFORNIA cu9ton9es0nlWN& WB -80045 psted 6-24-96 M rprs grdet tft �_.09» 04385 The following gives the additional specifications that were used In the manufacture of the members on this job: 1. Lumber Species DOuGLA5 FIRAARCH Grading rules WCLIB #16 pmgreph 154 thru 154C Grades 22T 20T 1.1 1.21) 1.2 L3 Slope of grain 1:16 1:14 1:12 1:08 2.11116,11sture Range content 8-12% Variation per member 5% S. End Joint HORIZONTAL FINGER JOINT 4. Adhesive COMMM to ASTM 2559-82 specifications. Type CASCOPHEN LT -5210 Batch Na S600049 5. Gluing prem 100 psi minimum Pressure period 12 hou rs mi n i mum Glue spmad 63 lbs. S. FabdcWon Conforms to specification of ANSI Standard A190.1-1983 BOISE CASCADE CORPORATION COMO" Mui 0UWfty—canna supsnIM ` Dazs AMERICAN V=0 VMVIS -- A RELATED CORPORATION OF AMERICAN PLYW000 ASSOCIATION 9166852831 OCT -08-1996 15:02 WESTERN BUYERS DC 9166852831 P{03 ov�se baii�liaes M�.nirV r� A.GVV11/1G1� 1 ; F Timber and Wood Products : -Group] , S OMER ORDER DATE Auk ORDIERIINVOICEN0. PA. sox ea • ao1sE, IDAHO e3707 396 6/24/96 2 09-04385-00 'FRMS CUSTOMER ORDER NO. ORDER DATE 2% CD ADE 15 DAYS -NEI 16 S ADI -8 6/24/2§ SHIP WEEK OF FREIGHT PREPAID 6/24/96 MPIES TO; MILL DELV BDFT TOTAL EST. ..PCS MARK SIZE LENGTH PRICE PRICE / PC BDFT WGHT STOCK ARCHITECTURAL BEAM 6 C31260 3-1/8 X 12 X 60' 320 1,919 3473 9 D51360 -5-1/8 X 13-1/2 X 60' 540 4,860 8797 AMOUNT, FREIGHT• s 'MISC CHG CE AMOUN +. PIECES F$UTpRDEE 6,79 EWEi� ED 12,170 9166852831 OCT -08-1996 15:03 WESTERN BUYERS DC Noise %;ascaae Timber and Wood Products'"Gr "'"'T'. P.O. BOX 62 0 BOISE, IDAHO 83707 ' PREPAID - 9166852831 P.04 A%A%N V YY LC IJV IYI C N 1 CUSTOMER ORDER DAni 6/24/96 1 09-04385-00 CUSTOMER ORDER NO. ORDER DATE 80045' SHIP WEEK OF 6/24/96 LOAD: LEGAL COMMON CARRIER TRUCK ` SPECIAL INSTRUCTIONS.. * *---- SPECIFICATIONS ---- *DOUGLAS FIR/LARCH *EXTERIOR GLUE *STRESS 2400-F V-4 *ARCHITECTURAL APPEARANCE - S3S *INDIVIDUAL WRAP *ENDS & SIDES SEALED *A.P.A./E.W.S.CERTIFIED *ONE END SQUARE ONE END WILD ; *CAMBER 2000' RADIUS *NO•SHOP DRAWING *ANSI A190.1-1983 REPLACES VOLUNTARY PRODUCT STANDARD -PS 56-73. * T t COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-754 PERMIT NO. APPLICATION AND PERMITS ASSESSOR PARCEL NUMBER 21-22-17 ZONING A-40 BUILDING PERMIT OWNER FORD JUSTESON 879-'5525 SO. FT. OCC. BUILDING VALUATION 2 4 8.00 OWNER'S MAILING ADDRESS BOX 469 BLOCK RD GRIDLEY 924 11 16,632.00 CONTRACTOR'S NAME SCOTT WALKER 695-0214 TELEPHONE coy 12,675.00 CONTRACTORS MAILING ADDRESS 9747 SINNARD AVE LIVE OAK Fireplace MA 3,500.00 CONSTRUCTION LENDER UNIWOWN Total Valuation Is im, 99 -no Fling Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 881-00 ARCHITECT OR ENGINEER RONALD KEY LICENSE NO. RCE18842 Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILINGD �r6 POOLE BLVD YUBA CITY, 95991 Penalty $ BUILDING ADDRESS 475 BLOCK RD PERMITFEE $ PLUMBINGPERMIT Filing Fee 20.00 GRIDLEY Each Trap 101 7.00 70.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP Solar or heat pump water heater 23.00 Water piping 15.00 USEOFSTRUCTURE SF L]{ Duplex ❑ Mobilehome ❑ Other SPECIFY Each gas water heater or vent 15.00 1 S_00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 1 nn TYPE OF WORK New 11 Addition ❑ Remodel.❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 2 BEDROOM 2 BATH W/ATTACHED GARAGE - Mobile Home S I G I W 920.00 PERMITFEE g Contractor ELECTRICAL PERMIT Filina Fee 20:00 Main Service OOOV OR LESS ( 200A OR LESS ) 23.00 Main Service ( 200A TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in, I force and effect. -7 License Class Lic. No. / /iro s-3 OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR NS. ( a ACC. ) SO. 3.SQ FT. 120.2 NEW CT CONST. MULTI.OUTLETLE NON-RESID. ( BRANCH CIRCUITS ) @7.50 POWER APPARATUS 8 SINGLE OUTLET CIR. ( ) EX. Occup. ( OUTLET OR FIXTURES ) 20 Q 1.00 �� S0 EX. Occup. ( OUTLETS(RESD.)EA ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE s 163.26 Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 9 Heating 100, 000 15.00 Cooling 5 T 20.00 Hood 6.50 .50 Ventilation 3 4.50 13.50 PERMITFEE S 75.00 Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forth comply with thos provisions. (- X (/(/__ Date �1�j�p �- Signature of Applicant - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over 50" deep and demolition or construct of structures over 3 stor'es.in height. Receipt No. �- •3Jo Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 Occ R3 CONST. TYPE VN I TOTAL FEE $ ZIg 1931.26 HA2. I D. FEES IMP FLOOD COF PARC PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. / l� Y l te/15 ZOO, ,� 1pv.E(oBMITEXPIRESON ✓ / / (Dgf WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK-INSPECTO GOLDENROD -APP CANT c= iCOUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - 7 County Center Drive - Oroville, Cali , rnia 95965 - Telephone APPLICATION AND PERMIT BUILDING DIVISION (916) 538-754 PERMIT NO. �� - /t�� ASSESSOR PARCEL NUMBER 2DIV— 7 lJ BUILDING PERMIT OWNER — 0(-d L4 t � �✓ �N Es '' So. FT. I OCC. BUILDING VALUATION �.s�� 4 /3 5 6,AILI OWNER'S MNG DRESS -IL_ romirmarOR'S NAME s J _�OIIr CO Rs MA{JNO ADORES / j i,✓ �/ ct e_ i v c O� C Freplace 145 3. a c7 C> (p Y Q CONSTRUCTION LENDER UNKNOWN Total Valuation $ Fling Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ '7 , .> G Aar CT ORENGINE A UCENSE NO. IZC 18 t1-2 Plan Checking Feel-, $_ s ((,+ $, 23�-" Energy Plan Checking Fee $ d .e, AAcwmar OR ENG&NEERs MAMJNG ADOREss Penalty S BULDLNGADDRESSOG ` / /� 7'l PERM FEE PLUMBING PERMIT Fling Fee 20.00 ,ry �`; Each Trap D 7.00 D.rez LOTNO. SUBONSIONSNAME PARCEL MAP Solar or heat pump water heater 23.00 Water piping 15.00 /s USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other 'SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 o D Building sewer 15.00 TYPE OF WORK New Addition O Remodel O Utilities ❑ Installation O Other ❑ -/ Describe Work: Q e g 6t o-y"�� �/ � � ���/""�N CA -P _ Mobile Home S I GI W I @20.00 PERMITFEE Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service ( e00v OR Less ./0 23.00 200A OR LESS Main Service ( 200A TO ,000A ) I I 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of oeriury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Coltractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. O 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: O 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) O 1 certify that in the performance of the work for which this permit is issued, I shall4 not employ an person in an manner so as to become subject to workers' p y y p y I compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date __— Signature of Applicant . ❑ Owner O Contractor O Agent � 1� An OSHA permit is required for excavations over 50" dee.P a �f olition or nstructilon of structures over 3 stories in height. �/ e T /�3' S0 NEN CONST. OWE LUNG OCCUP. ] r� OR ADONS. ( b Acc. BLOs. )-,3 .. 3.5¢ Ff. I IAL)" A y NEN CONST. MULTI -OUTLET ( ) I NON"RES*. 'AANCH CIRCUITS @7.50 POWER APPARATUS (a SINGLE OUTLET CIR. ) Ex. Occup. (OUTLE T OR FIXTURES) I I zo ng ,.o BA:.i. .00 EX. Occup.FIXED APPLNS. OR (OUTLETS (RESID.I EA ) I 5.00 Temporary Service 23.00 _ Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ Contractor MECHANICAL PERMIT I Filing Fee I 20.00_ Heating `J 01 v a Cooling 3,7- J 1) — --- Hood 6.50 t — Ventilation 3 3, -s v _ PERMITFEE $ Contractor Mobile Home Installation Fee Is —{ Energy Inspection Fee l'T , ,� $ CON r. p TOT L FEE I I NA2. O FEES IMP FLOOD COF PARC PO M ISS6E (-- This permit is hereby issued under tree applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. B pate _ 1 y 1 kh; 1 . '-'F'.'•r� . . �,. y „ 'v c..,r...r`r�-f%�,.,�Y-..�'t��.,�``�`R`'Vd%�.i'A^•�.. ..._,.^ _ .... r, . - _ x! COUNTYOF BUTTE - DEPARTMENT OF DEVELOPM ENT SERVICES - BUILDING DIVISION t ` 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 -TELEPHONE (916) 538-7541 -� PERMIT APPLICATION DATASHEET / 4e5o�t/ OWNER f Ur GC J (,/ S Proposed Building Use le") A. P. No. ';k 1 /7 Building Inspector AA -11 Date - 30-9-6 At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY F, 1. All items have been submitted . .................... .................. 2. Plot plans, 3/4 sets, signed by preparer of plans. � ` 3! Complete plans, 3/4 sets, signed by preparer of plans........:` ........... . 4. Engineered plans and calcs, 3/4 sets, with.wet signature on plans. . ~ ........... 5: Hazardous Material Form . ................................... 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout 'n-�I+ to (required priorto plan check). ... '. 9. Mobilehome to a anufa fer'� lation ' ructiogs ts. .......... . 1 Fees of $ - ... /. 7� .12 . .............. Impact fees as shown on ttached schedule. .... .................... 2. California Department of For -la r-approval/fees. ....................... . 13. Flood elevation letter (100 year flood) b C lifornia Engineer ................... 14. Sanitation and plot plan approval or�'v1 �k'� Health Department . ............ 9� 15. City of Chico plumbing permit . ......................................... 16, Plot plan and business; license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: _.,�_18. Contact Land Development about (A) Improvements (B) Drainage. ... . 19. Driveway permit (construction approval required prior to occupancy) ��: -' eK f./e - lc 20. Pre -inspection for �anBuilding Insns asiu � f required. . to pector (Date) 21. Contractor's license information. (No., Name tyle, Classification) . .............. 22. Certificate of Workmans'Compensation Insurance . ........................ . 23. Owner -Builder Verification (Given to ow Mail to owner _):::::.:... . 24. Recorded copy of Agricultural f ,&howledgement Statement. .................. 25. Letter of signature authorizAd8n. .......... Ca. t: ........................... 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use. . 28. Mobilehome utility clearance. ....!' �`� j .................................. 29. Documentation of legal access. ........ 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits. ..... .............................. . 32. Plan check list . ...................................................... ............... 33. 34. " When issue thep ggit,p oc ss as follows: Mail to owner. Mail to contractor. , Telephone ((00`1 OO / and hold for pickup at office. Deliver with inspector. Other CWi f aLGC f- C� Parcel Creation Acreage Applicant Date (� Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior termit issuaCcd (Circlnot checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, desf n r, owne , was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, ner, was advised of above required data by _ phone_ mail Co�lpter by _ Date Plans checked by (c /q Date_ Plans approved by Date Sets of plans on hold in File cabinet AP folder �-c Copy - Department of Public Works E.H. USE ONLY Plot Plm A—A-A 1 Plow PLu AnneW i smt to B.D. LQ -!S3 TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance �' a , a_ .r► � .tea, s! •. _ __ � Plan Approved for: Sewage Disposal -Clearance for ,-3 home. er Hold final for: Final clearance O.K. for: NOTE: Environmental •Health Specialist Water Supply: Public Private Well KI COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 OWNER ���"� ��S oN Fu l'(% A.P. #o2 PROPOSED BUILDING USEe-c J S DATE — 3 y REC. # DATE REC jV1SCHOOL DISTRICT FEES Cir 0 1 (paid at District Office) SHERIFF FEES (paid at Building Division) Residential......._x .34'c' _$ 3>'Q � S unit amt. Commercial (sq. ft.) . x =$ 3. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x =$ #units amt. Commercial (sq.ft.).. x =$ sq. ft. amt. 4. RECREATION DISTRICT FEES (paid at District Office) 5. THERMALITO DRAINAGE DISTRICT FEES ._._ .._ $400.00. (paid at Building Division) 6. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 7. WATER TENDER FEES (BATTALION # ) $200.00 (paid at Building Division) 8. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 9. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. APPLICANT zx(� DATE 30 Ar, BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One Form Per Building) School District Building Department No. A. P. Number Jurisdiction: City FV County Property Owner ��� ,,/ J u 5 Property Location/Address ILD / p t It' &'d r i ej /-e Subdivison Lot No. Residential Development 0 Sq. Footage r�5 No, of Living MHI Addition (Group R) Units Commercial/Industrial Sq. Footage New Addition (Including Exterior Roofed Areas) 9& Building Department Representati a Date (Floor Plans reviewed by School District Personnel) n" District Identification No. 1 / S 9. 41 /v f School District certifies that. "11 (-. ,, " (Applicant) i deal,. I ; I',Z M-5.S�S (Street Address)] (Phone Number) (City)r (State) (Zip Code) 100 i 4 has complied with the requirements or.6solution No. / / /� 3 5� by payment of $ representing VS/ a School District square feet.r� t� AB 2926 $ FULL MITIGATION $ Date M � Paid by Check # / 3, / �/ Remarks Bank Number 69, 9/ 3,Z # ff� Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.wk1!01/94)dmm ' ft ACCEPTED E® FOR RECORDING AT 8:01 A.M. J U L 18 .1996 BUTTE COUNTY RECORDER And when recorded mail to: Building Division #7 County Center Drive Oroville, Ca 95965 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The pr6perty desefted hernia is a4acent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation. plowing, spraying, pruning, and harvesting whieh occasionally generate dust, smoke, noise, and odor. Butte. County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discoa�oit from normal, necessary farm operations. All that real property situate in the County of Butte. State of California,, described as follows: CcDS%5 of gCi = acs t 74( G %S- /31c / eco , Date: L� - 'y- ��_ PROPERTY OWNERS: CLI/S State of California ) County of ) On &' - y-rl'�o before me, G�<I G'1�11b'!1%c7�'cJ persopally appeared personally known tq ane,.(Qr proved to- me on tfic basis of..satisfactury•evidence):to be the per"son(s) whose name(s);is/ane pbscril ed -to the within instrument and acknowledged to me that helshe/they executed the same in his/her/their anthorizt d ;capacity(ies), and that by his/her/their" sibnature(s) on the instrument, the person(s) or the entity upon behalf of :which he persons) acted, executed the instrument. WITNESS my hand and official seal. 4L. LEA WAGNER N �omy COMM. # 1072965 D MNOTARY PUBLIC - CAUFORMA((A Sigoature Sear: QCOUNTY OF BUTTE w Comm. Ekins Sept. 24. 1999 A.P.# .3 rA: COUNTY OF BUTTE BUILDING DIVISION 4Mx' ~� DEPARTMENT OF DEVELOPMENT SERVICES :•:, 1469 Humboldt Road, Chico, CA - (916) 891-2751 �. 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 r« i `± CORRECTION NOTICE 96-1-230 OWNER PERMIT NO. ti A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have'any questions pertaining to this matter, or need additional explanation, please contact this office immediately. S 4- Date (�— r � Inspector (� ' REV -10/92 ��•��: +v COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 ' 747 Elliott Road, Paradise, CA - (916) 872-6307 W.y. CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact -this office immediately. REV 10/92 ctOr t r . _. ` . , COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 :1 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist.at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, Date Inspector ;,� Co 4Z y REV 10192 CERTIFICATION-MJF"INSULATION'".. ADDRESS OR TRACT SACRAMENTO INSULATION CONTRACTORS ' SCOTT WALKER CONST.' 'rLOT'N . ❑' P.O. BOX 854, WEST SACRAMENTO, CA 95691 LIC. #202026 - P.O. BOX 4146, STOCKTON, CA 95204 LIC. #202026 i - ❑ P.O. BOX 1631, -RENO, NV 89505 LIC. #10675 - -, ❑ .P.O. BOX 9651, FRESNO, CA 93793-9651 LIC. #202026 ❑' 6470 B SOUTH PROCYON AVE., LAS VEGAS, NV 89118 LIC. #10675 469 BLOCK ROAD DATE INSULATI . N COMPLETED ( SQUARE FEET) ( SQUARE FEET) ( SQUARE FEET) TYPE OF INSULATION TYPE OF INSULATION • TYPE OF INSULATION MATERIAL MATERIAL MATERIAL FIBERGLASS FIBERGLASS FIBERGLASS FORM FORM FORM BATTS BATTS & BLOW BATTS MANUFACTURER'S PRODUCT I.O. MANUFACTURER'S PRODUCT I.O. MANUFACTURER'S PRODUCT I.D. MANUFACTURER MANUFACTURER MANUFACTURER OCF oUF CCE SCHULLER BAGS SCHULLER R -VALUE APPLIED R - VALUE APPLIED MIN. INSTALLED R - VALUE APPLIED INSTALLED THICKNESS INSTALLED THICKNESS WEIGHT PER SOUARE FOOT INSTALLED THICKNESS R-19 R-381 12 112" . KNEE WALLS IF R -VALUE IS OTHER THAN WALLS ABOVE MATERIAL FORM R VALUE MANUFACTURER FIBERGLASS BATTS OCF AIR INFILTRATION SEALANT MATERIAL MANUFACTURER FOAM - W R GRACE THIS IS TO CERTIFY THAT INSULATION AND/OR SEALANT HAS BEEN INSTALLED IN CONFORMANCE WITH APPLICABLE CODES, MATERIAL STANDAP DS AND REGULATIONS. �• • SI NATURE -INSULATIO CONTRACT O TITLE DATE 10/16/96 MANAGER- SIGNAT -GENERAL CO TRACTOR TITLE DATE REMARKS: + r� SIC -303 BUILDER COPY - �i PROJECT UdR� KEY & ASSOCIATES -- CIVIL ENGINEERS BY DATE 9 7/J 1646 POOLE BOULEVARD YUBA CITY, CA 95991 CHECK DATE 916/674.1565 SHEET ' OF t , A v D ,Qva4 P s t� P (�i%1 �Is�- . Q ST J'C-rGM 1r o a ` (o- a I D 66Q c.. WA -LL— V NeSkt ONLY see 0lE;Tk i,C_ WO 5 OrJ OAA- C -7&L C-'5 Z (r7(51:;) -A P eA 6 I*VS , -n:EP :i.61+T. L s AW F Tm 0-6up 0uJj35 T ALL W rT � LT SIVE 0-F M U56i, P'VESS/p4' 9 °LWNo. RCE18842 . y i Exp. J e 30, 1 `f'l9� CIViI i '{ FdF CA 1F PROJECT f KEY & ASSOCIATES v % BY DATE CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 CHECK' DATE 916/674-1565 SHEET OF . GIS � w��� L� ��a�t? i4-�,Dt✓�� , -�wQ�. z,��•�-�-� � �3� . OSSF-L '.�w�us loG!@ 3•�, Z:� . �./ P- L 17X 324 Zp(..t P -8w= Z80x 2,3Q. CcST I (A A -LL - 9 k t x 3,' rn 867x 2 1.0 14X a 6X?-UeI 1�,4�� X76 =>uI Z uj/� PasT�Auas , 5TT 34 -A Pa A ` s oQRpFESS/o We 00 No. RC 8'42 Exp. ' ne 30 1 97 CMI d n FOF CAQ P OJECT JUSTEiSdI�% KEY & ASSOCIATES J P�'/' BY —DATE -5/-9/9(0 =^+ CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 CHECK DATE 916/674-1565 C 1 q9 / SHEET OF r I { -PL-, ZD e -'r T R ! D—I $ J ,19 Za-ir , I t ` P, I �OCo x I. 1 to LNA (-A: tO FOIZ' 1,3 x14,5x 1,D'_ : Z1-.3 t tJ5E L.Xg6E'e- i{0.TKaV9,1-E= C8=,.2+1)XzO+�xZ►�3 32(p 6At- (9 X'.00 oQROFESS/04/ CPLD m 1 1 No. RCE10 42 1 ) _ ' I 1 I Exp. Ju 30,11 9' 1 z�� ,� ,.1.03 � � s � i IV F + t } I TEOF CAL1F�� �ooF c 4.5'X Z.0 k :100 ; , , - _ KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 PROJECT UsTB� t2r s BY c� DATE /9� CHECK DAT SHEET Z OF i AWT OF 14.0 t 1 . i r r U95 -yo X1,5 1 + t.x2v�z�5 ;�jb r I W'"L 1=reXlIx Z►5 GZO w1 - 4 2D K v Qp�pFE'SS/ e)rw - Sx X 15 z - 35v 4Q1-70 ��Qo�P`D -�-:I iNo. RCE18842 . 24-G ej r Exp. J e 30 P, 9 r U56FT M 55 SIM?s4)o S� r.1. 9 OFC LF +`�r25t —7 r ' . KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 PROJECT X01'6 00 Q65 BY DATE 57/14/96 CHECK DATE SHEET 2:1 OF L ��"�' S W .Q c Cit 1 a+ -7 G, x-12) ,3 Z4 . I Lr I 6vvew—"llie. -7:51d 115 S X95 Tv12- �� z �. ; 257'x- _ W •_�-.._w__ _.�., _.._•_. 51 Uw 14f/tHU 7Z. •rteAl _�f: ._.E 7_ iC-- i Sw X Z t,4-4 61 58 f I i_ ! 3 4 S (a . P1�W P.� 45�x 2!5 � 1.14c� 1 I d • � I , { I' i I ► ' •WAS.(..—; 5XII )('t,S 2_ 946,K 90 4—j �FESSIONq� jI Iu�� —T30 �o Q Pip C. oma !9 ! . a2 � �ti�l. �• Bk I14;o � ,'i2.��-790 0e=fA-IJEL A. ! qq KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 PROJECT U S r CS -4 J BY C..I� —DATE --5/11/96 CHECK' DATE 1 LT S 10 E UV H -u 5 w J 1:-7 + Z. 3(0-6(9,9 SHEET 4� OF 0 L T 5 119E D F 6- A -K- c k�-- o F N 0 s w _ 3. S 1-1 58 Ck _..._. PW /W t� G 6 12_ RpFESS/p ITIS TP-vsi Vo P-) TD P --(5A1', 6.44 SWcD c• ,��F� _ c7 Q .44 Z rzee,. C No. RCE188Q m m •EXP• ne 30, 10 7 VC/41l OF CALIF��- TR-VSS Ty UJ. _ W� �Tlo ? `v' d U �`c. 5',Z NOTE 0 55 N o £35PEr►� ' MSrbo GD�1i)►JUD� lli�.2 T o: WALL TI5 7-fL05s wD (o TO F( -OPT 0F'G ►t- sw.. b n SINGLE T-YLU55 OK- C_ o/U�1. 94 P�OVv KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 PROJECT jt)5T 50Q eQS C / BY L I DATE 7 ` 14'9 ('p CHECK DATE SHEET S X PT LOADS oV6-e w I u 1900 H' DSS S " 23, 1 1 5 OF g ¢ w 10 Doul tW L -TS Q�p�ESS/pN �`FO p�D C 9�R ,, �� rn No. RCE18842 ^' 11 � Expi Ju 301 197 VO ZO / (Q�ZX .1 Z — 2Z Cm 'v[� 9TF ctvl� � C OF CALIF -L0 17 ZDV 1 Z0.1 17�p (� rfi �.�. z¢b �• �, � L16 1.5I Z u AW KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 ' � 9 PROJECT (215 (15'' BY DATE SI r c 19� CHECK DATE Lo" e 420 P L. F SHEET G OF T�tJs`7 427V = 7-715-2. =Ok� 4 s ¢ 6 1. o A -O . 1 0 �O" ; ;z = 5 3 . Dv V 12 PO R -c-11 15gg'Z = X799 t? car. w�aru_ Ole_IZ ,0 ; t= -,to00 lr7v?6NT' WALL F'o PV- PAF---------------- Vyt :5��13� X 12 - 2e,7op IN I� Zz 1� = S(g 700) I9 12 i Z'7 < 75 r o�•c- a- X 'x � I HCl 0 D F 6 !.1 l� s 1Z 1� W 1®0 W t� D IM i . (o , o/QRpFESSlp�9` ��, PSD ------------ :No,:RCE1gg42 s VA F -XP. Ju a 30, 19 civi OF CAUF��� o Ax`p E i G r L ' 7 KEY & ASSOCIATES CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 916/674-1565 e h 7Ce�N6-iz- vwadPG Co 10 T- lio PROJECT JUSM5XJ BY D A T E CHECK DATE SHEET_ OF i I.o�b 145 Z . 1 >_oN(PoR,-- t! �bVISE T�-UxES 'Tu g � 0�- EX EI/-lbc�- WA-tL-:5 114 l 4) I :2 : ` S I L QRpFESS/0\ c, No. RCE18842 Ex une 3 , 9 7 J�9T clvl\ SOF CALF vVj x OP N o. ' USS 24 3GO x � 2 Fl�o1J s e 00 r k— W &1306 LOAV Y4 U�o._l29ov {b 900 7,;'Lex �z" G-LtJ 1. � vvl 2oU l7 7 24 5 ""'�� PROJECT ��)STf=Se1J F-�S KEY & ASSOCIATES QQ BY V�-�� DATES ✓pp� T CIVIL ENGINEERS 1646 POOLE BOULEVARD YUBA CITY, CA 95991 CHECK DATE 916/674-1565a_�� , - SHEET OF i pia f't-1 Kl,,rM LT .5,10 t5 ( � 7 0 9 20 Aft SIn tfl) Z 24 l% TK vssTu w�(-l. T�.�T E►�11D,o F tt ovs 1�p L w UALL No. RCE18842 ° Exp. h 30, ;n9— J' CIV OF C c, d RESIDENTIAL PLAN CHECKING GUIDE SNGLE FAIMILY, DUPLEX AND MISCELLANEOUS ONLY OWNER:BUII.DINGPE ER: �O �/ 3" PLAN CHECKER: A- P. NUMBER: oZ/ ' 22- GENERAL: e/ Zoning requirements: (side yards and number of permitted living units). Valuation. &3i Plans signed by designer. ,sl�j Proper description of work on application. Existing violations on property. �j Items on data sheet, (Impact Fees, Environmental Health, Developer Fees, etc.). �! Recorded notice of violation. PLOT PLAN: Complete parcel size and dimensions. Setbacks, side yards, easements, etc. Other buildings or structures. - Grading, fills and/or drainage. Flood hazard. Special conditions on creation map (Noise, S.R.A., Fire Sprinklers, Water Tender, Trees, etc.). F.A.U. & F.A.S. road setback. Building or utilities across for lines (Record form). Complete to scale plan with dimensions. Required windows for light and ventilation (Section 1203). Required windows for second exit (Section 310.4). Skylights (Section 2409 & 2603.7). Glazing in Hazardous Locations (Section 2406). Required room sizes, ceiling heights (Section 310.6). G.F.C.I. in baths, garage, kitchen, wet bar and exterior outlets (N.E.C. 210). 8. Lights, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. 9. Location ers, eating and cooling equipment, other electrical or gas equipment. Garage Cirewall, door size and closer (Section 302.4). Minimum of one 3'0" exterior door (Section 1004.6). Fireplace and wood stove location, alcoves and clearance, moke detectors (Section 310.9.1). Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS: Conventional Construction - Unusually Shaped Buildings (Section 2326.5.4). Standard bracing or engineered design (Section 2326.11.3). Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Elevations and wall construction details complete enough to construct building. Roof constriction details complete enough to construct building. Rafter ties or bearing ridge beam. Fireplace construction details and ca1c. if necessary. Garage door and/or porch header sizes. Stud heights. Adobe soils -.special foundation design. Retaining walls requiring design. Special Inspection requirements. [-leader size. r March 1996 3.2 MISCELLANEOUS ITEMS TO LOOK OUT FOR: Stairway details: landings, rise and run, head clearance. handrails (Section 1006). Guardrail details (Section 509). Brick or stone veneer (Section 1403). Exterior plaster - weep screeds (Section 2506). Proper roof pitch for roof covering (Section 1501). - Roof covering type - (fire hazard). Foam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts. Two exits on three - story dwellings (Section 1003). Underfloor access and ventilation (Section 2317.7). Attic access and ventilation (Section 1505). Combustion air for fuel burning appliances - L.P.G. requirements. Noise requirements on duplexes. nergy design. hing at all exterior openings. C.D.F. responsible area requirements. March 1996 VI 6 �PC�C�iL I�%l=,-�`1"I�l n..=L!� �i �'I,�'r�r�►—> TCZ���r�� � V r� � � � (.�lfr�2�= �L. (r tJ Cqc" © `7 3.3 CA Ford Justeson LS c/o Scott Walker 9747 Sinnard Ave. Live Oak, CA Re: Single Family Residence A.P. No. 021-220-017 With reference to the above sub: ect, attached is: [x] Plan Check List [ ] Red Marked Calculations [ ] Red Marked Plans [ ] Other: Action Required: [x] Comply with plan check list [x] Resubmit revised plan Sheets as necessary [x] Resubmit calculations with revisions as requested [ ] Return originally submitted material utte Count BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE. CALIFORNIA 95965-3397 TELEPHONE: 19161 538-7541 FAX: (916) 538-2140 Date: 7/9/96 Permit #96-1230 Should you have any questions, don't hesitate to contact me at (916) 538-7541 Monday through Thursday. Sincerely, George R. Kellogg Plan Check Engineer cc: Ford Juste Box 467 lock Road Gridley, CA Ronald Key 1646 Poole Blvd. Yuba City, CA 95991 PLAN CHECK LIST Permit Applicant: Ford Justeson Permit #96-1230 Date: 7/9/96 1 Plans for the above referenced pro' ect were reviewed by this office. Please provide additional information and/or make revisions to plans, specifications, or calculations as follows: Provide engineering calculations and details for the concrete block walls shown on the elevations for the sub: ect residence. Provide method of lateral load transfer between the roof diaphragm and shear walls in the porch areas. Provide details and engineering calculations. If detail 5 on sheet S5 is part of system to be used, give complete nailing schedule along load path. �� On, sheet 2 of Mr' Key's calculations dated 5/196, the v�nnd load tributary area from the front of th he Ouse would seem to control the right side design rather than the rear tributary area used in the calculations. Please check. On the same -wall check whethand 815' she?a r waalls'roequlire hold downs. On sheet 3 of Mr. Key's calculations dated 5/14/96, the 8.58' shear wall used to resist lateral forces is shown as having a door in it on the plans. Verify and revise plans and calculations as necessary. LAND DEVELOPMENT BUILDING / ENVIRONMENTAL HEALTH - PERMIT CLEARANCE Building Permit No. OWNERSvv ST'ESocJ / �or'Z0 A.P. --t�+ NAME: ("-)in d C 1'-"(,1�5 i�l NUMBER: r r�r7c lJ -C (% Pm LAST NAM ii -r COUNTY ZONING DESIGNATION: A 4o FLOOD ZONE: FLOOD MAP: S 7 5 13 APPROVED:CONDITIONALLY APPROVED: RESOLVE PROBLEMS PRIOR TO APPROVAL: PARCEL CREATION BY DEEDS OR MAP DEED INFORMATION: DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: LEGAL ACCESS REQUIRED: YES NO YES NO COMMENTS/CONDITIONS: ftL-L- CoN►211-101-43 ot= A-hPrZoy14-L- Foyz 9t)vrjvAl2Y L -(i -)L-- MoO, M VS 1' ►3C- CbMPL-ET-Q9 P(4to,2 Tc) ISSN ptNc OP 6 {y PEf2M t T'5 1F 13 L M 0E2--05 (-t Pry E r -N (2 a= C.0 Y;L0 f£ C> C`'1 Prt nJ T-Pk-rE SE 6PCr- M MAP INFORMATION: >; vRV iLC ?r2-or-7Et2 T-,-{ Lirves . DATE OF RECORDING LOT BOOK PAGE COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DN/S/ON UNLESS OTHERWISE NOTED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a ft.building setback from right-of-way/centerline of —3. Maintain a 100 ft. leachfield setback from all existing wells. 4. Maintain a ft. leachfield setback from —5. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. _ 6. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. —7. Connect to a public water supply. —8. Connect to a public sewer system. —9. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 131D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. _ 10. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ _ 11. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) _ 12. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010 _ 13. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as statea in the Oroville Area Traffic Mitigation Fee Agreement. PoynnW to bs made to dw Plawwft DidsiwL _ 14. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. 15. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. X 16. Pay school impact mitigation fees. X 17. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II of the Butte County Code. _ 18. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. _ 19. If any cultural resources are encountered during ground disturbing activities, all work shall cease in the area of the find pending examination of the site by a professional archaeologist. This person would then be able to assess the site significance and suggest appropriate mitigation measures. 20. 21. 22. 23. 24.- 25. WO 1NRIdO1303 ONVI LD 9/96 - C:\WP51\FOHMS.K\BLDOPERM.CLR .. . ' .•. v . .II • . r: fti,y : �. �, -1 ` i � � _ ' r 1. l' O ]PARR.CG- B ���D�..I.dCAES�t a. ,. �, r . AEM. KED . f: ..,:.. Q .. . ':�: r A . .'•s'r - /: ;�� , `: $3� ;:�:...,. .. . _:�:.�.� J • - �ti' i. • �. ;:,,; P. ROp08ED • .. : _- .. :; . .. {:a::` i.:1. ;'. t . �, r _: . t:: L , i •; . %Y-; r•:. r • . 1V •TD'• A i' •,:: ',. r� �. . 1• . i .—-'. MD V _: �. ED r<: .{.. �.. L' \!' .]' .. V '. H::.S . -`,r 0 E `i;, X. �� . . >• . *o. :;:. . t.� :. ' is=�:� ���:� �.�:� Tn I: 2 , l S+ \. :{: i I:' :� �.,. :� .i .., :�1, ; �.y1 Y• y Y• tr.' _ `, I �• > .. i'j •.: j.: • > .. t -. ... . . - .. _.. .... ' �P'fif ' ft:? ;. : CES .: ;:.� t :;: i :> =k %1 v r. P:: }q 5 :=r ,, J'' ] a �' p t• 1 :. �.. i . Vit, ,•" ',)'�•' I O.. r '4:• - �•i y.. •.. ;,( :. »i '. dt•.'. ,.,��. .CPO.•r- .:r . y'•: i �' ~'i% I. �' 'i _ i4' .:,. . .. ... .. ...ll� ' .. .. . J.. - '. n... ::.:i { ... �,. 'J =: 1. °1:` _ .:r' t: -v •~. ♦' ] al`� /. Ir.. 11 mow. ..ri f :i 1 . _- . V f ! :. r' 1:. �?S i, r. ,r. - Y if i. _ '., o� A' >a 1 �,:.:. .... . :t. ..,::..• .. is ..� le' V~' l T •' .J`r . v -.t. .j �y• Yi. ri {' p r -f• " q., /./.. �' moi• \ =r»,,y e. . r:+ .•s' �\r r' / ✓( •1. :.i: r:• , ti .` 1. 38I. - :r' r5- i': ,.k. w' w ,• '(:.... moi:. '� '', 1 � i.L l� .� ti • t. �1 C'r n ,: ';,:r. � r. Q •In •b .. ' S'' •fir �. _ 'txr = _ _ 'i y ;:�` - .;�'. r � S A 'F.: _ 1 �;Y'. c ✓Y.' r - ' ',5 . u l�e•<_ . :w:. :;. T �D t% :S l H'. :....'C <, <� .....] .. .`.:. 1': i tGC,llr- S .11 .. .. . ,.. _.. .. - r -.: - T,' •�.'. •'')i. 'i. s r.,; ' - L' :i:. ". i:. . t( � '1 �i �:::.. ,s.,. ' % "' :r•• r :•iY �, 1.' '1 . 1I 'i:.,t'� u4 . , .. .... J:.. : J • 1' .. . •I.1. r. > .F 1. r .+ ... . ... i_' >9 '. �' ,: =ti, a, r Y: 7... .'': •']• ��'i . :y �-n' 1 ,l:.: ' t t +: \. ::,f.•%.Q.J -fir:. "L. 'j .r y�, t !ti t :?' Y. P +ti , = 4 n : f'' . d 'i r r. . J.: 1' J, :r 7 1, r1. .3 • i° v: :: / p: 'I'Ni�__ :ni.• J:^ v� r+ t ] • - tt. e.' 'd . 1 '' F f :Z° i : f :;V _:'.. . a:,v ; 'f r "S i• . t, t• '7'• f ••6 a y: " �, y P . >� D.• k. u i 'Y 1 d n' JI i.. a" ''i+'' r 6 - - b :.C' 1 1.!:+ . _ _ n-. `1 . >] !_ t 't rl ; �f a J 7 y, . } ti l' .gip. '4' - 1' x .. �. S' ' . �.%' it '] ',C °nr !a tri 1 .i '•i. .A�• :1. , �'h•,. r: .: Win• a,v , .. ' n .. .- ..1.l. :. .Y{, •'1• Y,.. +.. ] ,\1:.. ., ..:•r�, N4.',t,':a. •: '.r _at1���, >I'. .. •'i'.. .,.'L ,. ..rS`, .r".. c, a. ... CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R JUSTESON_2512_PLAN�J Date........ 05/27/96 Project Title........� Project Address........ BLOCK ROAD ******* --------------------- BUTTE COUNTY *v4.50* Documentation Author... RICHARD TALLE ******* Building Permit # Talle Design 206 Bridge Street Plan Check Date Yuba City, CA 95991 916-674-1670 Field Check Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-JUSTESON Wth-CTZllS92�P-r-ogram-FORM_CF-1R User#-MP1419 User-Talle Design Run -BASE CONDITIONf GENERAL INFORMATION ------------------- Conditioned Floor Area..... 2512 sf Building Type .............. Single Family Detached Construction Type ....... New Building Front Orientation. Front Facing_180_deg_(_S) Number of Dwelling Units... l Number of Stories.......... 1 Floor Construction Type.... Raised Floor Glazing Percentage......... E-12-I-6—Ii—of—floor area Average Glazing U -value.... 0.57 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Assembly Type Type R -value R -value U -Value Location/Comments ------------------------------------------ -------------------------------- Wall Wood R-19 R=n/a 0.065 TO OUTSIDE, TO GARAGE Roof Wood R-38 R-n/a 0.029 ATTIC Floor Wood R-19 R-n/a 0.037 TO CRAWLSPACE Door Wood R-0 R-n/a 0.330. TO OUTSIDE, TO GARAGE FENESTRATION ------------ # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type ----------------� - ----- ----- ------------------------------ ------------- Window Front ✓(S) 25.0 0.530 2 drapes None Yes Vinyl Window . Front (S) 0 0.510 2 drapes None None Vinyl Window Front✓6(S) -.0 0.530 2 drapes None Yes Vinyl Window FrontL�/,(S) 2440 0.530 2 drapes None Yes Vinyl Window Fron (SW) 7.5 0.520 -2 drapes None Yes Vinyl Window Left✓ (W) 24.0 0.530 2 drapes None Yes Vinyl Window Left -(W) 25.0 0.530 2 drapes None Yes Vinyl Window Back✓(N) 25.0 0.520 2 drapes None Yes Vinyl Window Backe/ (N) 4.0 0.510 2 drapes None � s�✓�nyl Door Back `// ( ) 53.0 0.780 2 •Dra es.Std None ,,`` � Window Bac kV ) 15.0 0.520 2 drapes None Ov Viky- l Window Right/�EE) 15.0 0.520 2 drapes None G Q°[��iinyl Door Righty/� E) 20.0 0.550 2 drapes No' �� xq Wood Window Rightl/(E) 4.0 0.510 2 drapes OYes Vinyl P. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title. JUSTESON 2512 PLAN Date. . 05/27/96 MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM CF -1R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- Area Orientation (sf) Window Right (SE) 72.0 Window Right (SE) 7.5 Type ------------ InteriorVert InteriorHorz FENESTRATION, ------------ # of Interior U- Pan- Shading/ Value es. Description 0.530 2 drapes 0.520 2 drapes Exposed -------------- Yes Yes THERMAL MASS ------------ Area Thickness (sf) (in) ------ --------- 30 4..0 54 1.0 HVAC SYSTEMS Exterior Shading None None Over- hang/ Framing Fins Type Yes Vinyl Yes Vinyl Location/Comments ------------------------ FIREPLACE ENTRY WINDOWS USED FOR THESE CALCULATIONS ARE: PHILIPS VINYL USING THE CERTIFIED VALUES FOR SUCH. WATER HEATER VALUES ARE BASED ON A STATE MODEL 510 OR EQUAL. HVAC VALUES USED FOR THESE CALCULATIONS ARE BASED ON THE FOLLOWING: A/C SEER 10.0 MIN., FURN. AFUE 780-o MIN. Minimum Duct Duct Thermostat Equipment Type Efficiency Location ------------- R -value ------- Type ------------ --------------- Gas ------------ 0.780 AFUE Attic R-4.2 Setback AirCond 10.00 SEER Attic R-4.2 Setback WATER HEATING SYSTEMS --------------------- Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ------------ ----------- Water Heater to meet ------------------- minimum CEC Standards -------------- ------ ---------- SPECIAL FEATURES/REMARKS WINDOWS USED FOR THESE CALCULATIONS ARE: PHILIPS VINYL USING THE CERTIFIED VALUES FOR SUCH. WATER HEATER VALUES ARE BASED ON A STATE MODEL 510 OR EQUAL. HVAC VALUES USED FOR THESE CALCULATIONS ARE BASED ON THE FOLLOWING: A/C SEER 10.0 MIN., FURN. AFUE 780-o MIN. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title .. JUSTESON 2512 PLAN Date 05/27/96 MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM CF -1R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- COMPLIANCE STATEMENT -------------------- This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... GLADYS JUSTESON Company. Address. Phone.. License. Signed..A -- L (d e) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... RICHARD TALLE Company. Talle Design Address. 206 Bridge Street Yuba City, CA 95991 Phone... Signed.. (date) COMPUTER METHOD SUMMARY Page 1 C -2R Project Title JUSTESON 2512 PLAN Date 05/27/96 Project Address........ BLOCK ROAD ******* ----- BUTTE COUNTY *v4.50* Documentation Author... RICHARD TALLE ******* Building Permit # Talle Design 206 Bridge Street Plan Check Date Yuba City, CA 95991 916-674-1670 Field Check Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM C -2R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- MICROPAS4 ENERGY USE SUMMARY = Energy Use Standard Proposed Compliance = _ (kBtu/sf-yr) Design ---------- Design ---------- Margin = ---------- _ ------------------------ - Space Heating.......... 12.62 10.91 1.71 = = Space Cooling.......... 13.17 .12.91 0.26 = = Water Heating.......... 10.40 10.40 0.00 = = Total 36.19 34.22 1.97 = _ *** Building ----------------------------------------------------------------- ----------------------------------------------------------------- complies with Computer Performance GENERAL INFORMATION Conditioned Floor Area..... 2512 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 180 deg (S) Number of Dwelling Units... 1 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... Raised Floor 1 21328 cf 2512 sf 2512 sf 0 sf 12.6 % of floor area 0.57 Btu/hr-sf-F 8.5 ft COMPUTER METHOD SUMMARY Page 2 C -2R Project Title JUSTESON 2512 PLAN Date 05/27/96 MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM C -2R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- Zone Type -------------- HOUSE Residence BUILDING ZONE INFORMATION ------------------------- Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area (sf) (cf) Units itioned Type (ft) (sf) ------------------ ------------------------ ------ --------- 2512 21328 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val ----- Azm Tilt Gains Reference --- ---- ----------------- ---------------- Comments -------------- HOUSE ------ ----- 1 Wall 72 0.065 19 180 90 Yes None 2 Wall 48 0.065 19 180 90 Yes None TO OUTSIDE 3 Wall 48 0.065 19 180 90 Yes None 4 Wall 348 0.065 19 180 90 Yes None 5 Wall 23 0.065 19 225 90 Yes None 6 Wall 280 0.065 19 270 90 Yes None 7 Wall 148 0.065 19 0 90 Yes None 8 Wall 172 0.065 19 0 90 No None TO GARAGE 9 Wall 284 0.065 19 0 90 Yes None 10 Wall 192 0.065 19 90 90 Yes None 11 Wall 52 0.065 19 90 90 Yes None 12 Wall 51 .0.065 19 135 90 Yes None 13 Wall 23 0.065 19 135 90 Yes None 14 Roof 2512 0.029 38 n/a 0 Yes None ATTIC 15 Floor 2512 0.037 19 n/a 0 Yes None TO CRAWLSPACE 16 Door 40 0.330 0 180 90 Yes None TO OUTSIDE 17 Door 20 0.330 0 0 90 No None TO GARAGE FENESTRATION SURFACES # of --------------------- Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description ----------- HOUSE ----- ---- --------- ------ --- -- --- --- ---- ---- --------------- 1 Window 25.0 2 Vinyl Slider 0.530 180 90 0.88 0.78 2 Window 16.0 2 Vinyl Fixed 0.510 180 90 0.88 .drapes 0.78 drapes 3 Window 40.0 2 Vinyl Slider 0.530 180 90 0.88 0.78 drapes 4 Window 24.0 2 Vinyl Slider 0.530 180 90 0.88 0.78 drapes 5 Window 7.5 2 Vinyl Slider 0.520 225 90 0.88 0.78 drapes 6 Window 24.0 2 Vinyl Slider 0.530 270 90 0.88 0.78 drapes 7 Window 25.0 2 Vinyl Slider 0.530 270 90 0.88 0.78 drapes 8 Window 25.0 2 Vinyl Slider 0.520 0 90 0.88 0.78 drapes 9 Window 4.0 2 Vinyl Fixed 0.510 0 90 0.88 0.78 drapes 10 Door 53.0 2 Metal Slider 0.780 0 90 0.88 0.78 Drapes.Std. 11 Window 15.0 2 Vinyl Slider 0.520 0 90 0.88 0.78 drapes 12 Window 15.0 2 Vinyl Slider 0.520 90 90 0.88 0.78 drapes COMPUTER METHOD SUMMARY Page 3 C -2R Project Title JUSTESON 2512 PLAN Date. 05/27/96 MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM C -2R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- FENESTRATION SURFACES OVERHANGS AND SIDE FINS # of ------Overhang----- Vent ---Left Fin--- ---Right SC SC Interior Area Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade ---- Description --------------- ----------- 13 Door ----- 20.0 ---- 2 --------- Wood ------ Hinged ----- 0.550 --- '90 --- 90 ---- 0.88 0.80 drapes 14 Window 4.0 2 Vinyl Fixed 0.510 90 90 0.88 0.78 drapes 15 Window 12.0 2 Vinyl Slider 0.530 135 90 0.88 0.78 drapes 16 Window 7.5 2 Vinyl Slider 0.520 135 90 0.88 0.78 drapes OVERHANGS AND SIDE FINS ---Window-- ------Overhang----- ---Left Fin--- ---Right Fin -- Area Left Rght Surface (sf) Hght Wdth Dpth Hght ---- Ext ---- Ext ---- Ext ---- Dpth ---- Hght ---- Ext ---- Dpth ---- Hght ---- ----------- HOUSE ----- ----- ----- ---- 1 Window 25.0 5 5 6.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 3 Window 40.0 4 10 2 .8 n/a n/a n/a n/a n/a n/a n/a n/a. 4 Window 24.0 4 6 2 .8 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 7.5 5 1.5 7.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 24'.0 4 6 2 .8 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 25.0 5 5 2 .8 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 25.0 5 5 2 .8 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 4.0 2 2 8.5 .8 n/a ..n/a n/a n/a n/a n/a n/a n/a 10 Door 53.0 6.6 8 8.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 15.0 5 3 8.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 15.0 5 3 8.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 20.0 6.6 3 8.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 4.0 2 2 5.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 15 Window 12.0 3 4 10.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a 16 Window 7.5 5 1.5 7.5 .8 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat ------------ Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments --------------- HOUSE ------ ----- ----- -------- -------- -------------------------- 1 InteriorVert 30 4.0 21.0 0.59 R-0.0 FIREPLACE 2 InteriorHorz 54 1.0 24.0 0.67 R-0.0 ENTRY COMPUTER METHOD SUMMARY Page 4 C -2R Project Title . JUSTESON 2512 PLAN Date 05/27/96 MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -FORM C -2R User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- System Type ---------------- HOUSE Gas AirCond HVAC SYSTEMS ------------ Minimum Duct Duct Duct Efficiency Location R -value Efficiency ------------ ------------- ------- ---------- 0.780 AFUE Attic 10.00 SEER Attic R-4.2 R-4.2 WATER HEATING SYSTEMS --------------------- Number in Energy Tank Type Heater Type Distribution Type. System Factor ------------ ----------- ------------------- ------ -------- Water Heater to meet minimum CEC Standards SPECIAL FEATURES/REMARKS WINDOWS'USED FOR THESE CALCULATIONS ARE: PHILIPS VINYL USING THE CERTIFIED VALUES FOR SUCH. WATER HEATER VALUES ARE BASED ON A STATE MODEL 510 OR EQUAL. HVAC VALUES USED FOR THESE CALCULATIONS ARE BASED ON THE FOLLOWING: A/C SEER 10.0 MIN., FURN. AFUE 780-. MIN. Tank External Size Insulation (gal) ------ R -value ---------- HVAC SIZING Page 1 HVAC Project Title . JUSTESON 2512 PLAN Date........05/27/96 Project Address........ BLOCK ROAD ******* ------------- BUTTE COUNTY *v4.50* Documentation Author... RICHARD TALLE ******* Building Permit # Talle Design 206 Bridge Street Plan Check Date Yuba City, CA 95991 916-674-1670 Field Check Date Climate Zone........... 11 --------------------- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-JUSTESON Wth-CTZ11S92 Program -HVAC SIZING User#-MP1419 User-Talle Design Run -BASE CONDITION ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Floor Area ................. 2512 sf Volume ..................... 21328 cf Front Orientation.......... Front Facing 180 deg (S) Sizing Location............ YUBA CITY Latitude ................... 39.1 degrees Winter Outside Design...... 29 F Winter Inside Design....... 70 F Summer Outside Design...... 101 F Summer Inside Design....... 78 F Summer Range ............... 36 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used..:... No Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Note: The loads.shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) -------------------------------------------- Opaque Conduction and Solar...... 12249 ----------- 5779 Glazing Conduction ............... 7400 4151 Glazing Solar .................... n/a 8813 Infiltration ..................... 12576 4168 Internal Gain .................... n/a 2550 Ducts ............................ 3223 2546 Sensible Load .................... 35448 28007 Latent Load ...................... n/a 5601 Minimum Total Load ----------- 35448 ----------- 33608 Note: The loads.shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. .L��3i260e')/ Foul ),f. y is' 13 toe -k Road / 65 ------------- . 0 IIS -47414 J" SI i e�)��a0-0'2 LAN n lu P o oseol► PLANNING DIVISION -BUILDING PLAN AP ROVAL ��' �� g f p User 1,k Date: ` ..... J° Ottter.9 —Arcpin.9 Pariun Landsca 9n I Si ature: 60 :._.... ............:.... .. - -...............................................- • - - - -- -• --- -- - :.. _: . - - I -------....-------.._---------------•---•-•-•••------- Assessoes ParcAel P umber: 0 ID L91 o ® 0 © m U ®Scale: Scale: I" _ Owner Name k Addrr-ss l Phone No. 75 ?S Site Location 42 N- ;, nuc � � iSF.i� #7 Contact: o•e�. 3� o Contact: Narne `rAo jTQ S OQ_o L LA0 -5� Phone,j3 0 - 2�� _ FOR OFFICE U8E ONLY Zoning: General Plan Desig: Size, Ams PROVIDE FOR ALL ADJACENT PARCELS SIZE (AC): ZOMNC: GEN PLAN: USES: all m• 0 2Gwo N d Sd NOIIY901 T13M M 0 4*