Loading...
HomeMy WebLinkAbout022-350-061022-350-061 PERMIT #97-2392 C.H.I.P. - Lot #11 (FOWLER, Margaret) 465 Trent St., City of Biggs New Single Family 411M B08-0131 c°,p Q- D 022-350-061 MISCELLANEOUS Re -Roof RE -ROOF SF(20 SQ) 465 TRENT ST FOWLER, MARGARET L. S x RESIDENTIAL 022-350-061 PERMIT #97-2392 C.H.I.P. - Lot #11 (FOWLER, Margaret 465 Trent St., City of Biggs New Single Family PERMIT NO. PERMIT EXPIRES OWNER CONTR. ASSESSOR PARCEL 52,My 3i LOCATION/�4 9-61. it OFFICE COPY. Address I GAS Meter By Date4 � LEC ETRIC Meter By Date OFFICE COPY Address GAS Meter By ELECTRI Date Meter By Date i Temp. Power Pole Called PG&E Temp. Elec. Service Called PG&E ,,Temp. Gas Service i Called PG&E —C -,JOB FINALED (Date) Signature tooe (Rev. 12/96) COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 97-2392 APPLICATION AND PERMIT PERMIT NO. ASSESSORPARCEL 2-351 ZONING BUILDING PERMIT OWNT�A1tGARET MiiE@ TELEPHONE SO. FT. OCC. BUILDING VALUATION 13q2 1 OWNERS MAILING ADDRESS 11 462 U 8 316 CON�TRpA,CTP�Fj'Su NAME V r9 �Z TELEPHONE �f 40 C 520 CONTRACTOR'S MAILING ADDRESS CON�T�pU'T`ON LENDER , Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 71.044.00 ARCH KI;U El'l:lO. 'i`Z C21783 Filing Fee $ 20.00 Permit Fee $ 513.50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUILD N(a {LDD STREET FWEIIT b5 r Energy Plan Checking Fee $ 23.00 $ CITY OF GX BIGGS PERMIT FEE $ 579.50 LOT NO11 SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 8 7-0056.00 Solar or heat pump water heater 23.00 Water piping 15.00 15.M Each gas water heater or vent 15.00 TYPE OF WORK New E". Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: MASTER Rini q 4 if PLAN 1152 Gas piping system 1 -5 outlets 15.00 1`3.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ 1.116 .00 ELECTRICAL PERMIT Filing Fee 20.00 Main Service ioon ORLEss 23-0023.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.P License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. OR ADONS. ( a Acc. BLDs._14 SO 3.51tF: NEW NON -R SrIDT AUNL I-""' 97,50 OWER APPARATUS S SINGLE OUTLET CIR. OUTLET OR FIXTURES Ex. Occup.BAL 20 @ 1'00 @ .so 0 NS Ex. Occup. OFITXEts q S p,OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE $ 99. Si} WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 1 20.00 Heating Cooling Hood 6.50 6,50 Ventilation PERMIT FEE S 65.50 Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith complywith those provisions. l Datp _/,_�% _ Si0a ure of Applicant- ❑ Owner ❑ Contractor EYAgent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 Occ CONST. TYPE TOTAL FEE $ 926.50 HAZ. D. FEES IMP FLOOD COF PARCEL PD HD IS7 This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. ,%%����q By /4,01F` .J Date /' // 12//`� _ PERMIT EXPIRES ON /// ? /9 Date ReceiptNo. LJ 1L4 4it2b.t L:3 " 9b $13W.50 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT V=OK O = Not OK Not `=NotRepaldyble MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. 'Zoning Requirements -Setbacks -Easements 1. Zoning Requirements - Setbacks - Easements 2. Footings; SoilsSize-DepthSpacing-Connectors-Steel 2. Soils; Special MH Support Sketch 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer, Locatiorr-Test-Fall-Q"oncrete 4. Wood Awn.; Posts-Beamsfittrs.-Cortnectom Shthg.-Rfg.-Bracing 4. Water; Location:%st-Easement Needed (Sketch) 5. Alum. Awn.; ColumnsConneebonsSplice-Decal-Eridosures 5. Electricity; L,ocadon-Clearances-amd-/ /Amp -Concrete 6. Carports; Windows -Doors 6. Gas; Location -Test -Wrap; / fUt. / /NaL or/ WtL/ /LPG 7. Electric 7. Well Clearance & Disconnect S. Frrng.; Sils-AnchorsStuds-Rttrs-Trusses 8. Utility Clearance 9. Siding; Nailing VeneerStucca-Mesh 10. Root; Shthg-Roofing Date Card B-1 Date Card B-1 Date Cana B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements- Setbacks Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line POOLS (Plans) OK except #'s 3. Gas; MH Test -Demand -Valve -Connector 1. Setbacks -Easements 4. Electricity; MH TestCrossovers-Breakers-Clearances 2. Soils; Compaction -Structure Stability 5. Drain; MH Test -Fall -Flex Connector 3. Pod Structure; Steel -Connections -Thickness Dead Men-Uning 6. Water; MH Test -Regulator -Connector 4. Elec.; Receptacles and Lighting, Distance -GA 7. Water and Sewer Connected -C/O to Grade -HD Approval S. Elec.; Pod Lighting; 15 Volts-GFI . 8. Gas and Electricity Tagged 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 9. Tie Downs-Type4nstallation Cert 7. Elec.; Bonding; Metal w/5'-Cinculating Equip. -Heater 10. Exits; Insp.-Sketch 8. Elec.; Grounding; Equip. w/3 Circulating Equip. -Pod Lghtg. Boxes-Enclosures-Panelboards4ns. to Main in Conduit 11. Cert of Occupancy 9. Health Department Approval 12. Permanent Foundation Only: License Decal 10. Plumb.; Cir. Test -Nater Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. 'Zoning Requirements -Setbacks -Easements 2. Footings; SoilsSize-DepthSpacing-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beamsfittrs.-Cortnectom Shthg.-Rfg.-Bracing 5. Alum. Awn.; ColumnsConneebonsSplice-Decal-Eridosures 6. Carports; Windows -Doors 7. Electric S. Frrng.; Sils-AnchorsStuds-Rttrs-Trusses 9. Siding; Nailing VeneerStucca-Mesh 10. Root; Shthg-Roofing 11. Ext; Steps -Doors -Landings 12. Braced WaU.Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pod Structure; Steel -Connections -Thickness Dead Men-Uning 4. Elec.; Receptacles and Lighting, Distance -GA S. Elec.; Pod Lighting; 15 Volts-GFI . 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5'-Cinculating Equip. -Heater 8. Elec.; Grounding; Equip. w/3 Circulating Equip. -Pod Lghtg. Boxes-Enclosures-Panelboards4ns. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Nater Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card 8-1 ✓ = OK O = Not OK - = Not Applicable * = Not Ready RESIDENTIAL (Single & Duplex) Date / UNDERFLOOR (Plans) OK except rs 1. ZoningSetbacks-Easments-FloodSlope. Main; Soils-Elec. Gmd. / p Ftg. Depth Fig. Garage; Soils-Steel-Elec. Gmd/ P Fig. Depth _ 4. Ftq. Porches & Decks; SoilsSteel-/ P Fig. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped . 6a. Hold Downs and Special Anchors . Date FRAMING (Continued) h/4f'C1Ling. Joist-Rttr Ties-Purlin-roff Brac.-Truss-Shting.-Rfng. Fire lace Ties or Type A Flue -Fireplace Throat clearance Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 1�a0. Bdnn. Windows or Exiting Doors -Sill Hgt & Dimensions 51. Garage Fire Protection Framing ropety Line Firewall & Opening Doors -One 3 -Check Garage 3rd Story, 2 Exits irriNidth-Headroom-Rise-Run-Landing-Fire Protection VW -Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Glazing Area -Glass Protection -Skylights -Plastic ea ails; Nailing -Bolts 60. ce Interior / Exterior Wall Panels Insulation -Walls -Ceilings , Infiltration-Wa[Is-Windows Date - - Card B-1 Date Card B-1 Date ,: c Card B-1 ate Card B-1 Dat FINAL (Plans) OK except #'s 63. Ext Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace; Vents -Clearance -Comb, Air-Conector- In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground. -Air Gap -Cooking Clearance 73. Elec. Outlets & Rece ticales at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr; Vents -Clearance -Comb. Air Connector-P.R.V. In Garage; Above Floor -Meth. Protection 77. Plb., Elec. & Mach. Equip. Listed for Location 78. Elec. Receptacles in Garaqe (G.F.I.11-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor 0 Yes 82. Following Instid./Drive 0 Yes 0 No/Walks 0 Yes 0 No/Planters 0 Yes 0 No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throught House 89. Glass Protection 90. Corrections from Previous Inspections 91.Gas Test -Meters Tagged, Gas -Electric 114 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy ¢ mpliance Certificate -Other Certificates Date Card'B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: L/19. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. UF. Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 1 14. Girders -Sills -Anchor Bolts -Joists Vents-Crippies 15. Access & Ventilation 16. Insulation DateC B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s ater Htr; Vent -Access -Combustion Air Baffle 8. ater Pipe; Test & Anchor -Nail Protection 9. D.W.V. Test Fittings &Anchor -Nail Protection 20. ower Pan; Test, First Floor -Tub Access Test Tub & Shower, Second Floor -Tub Access Gas Pipe; Sixe & Anchors Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection JZIT4. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Site Boxes & No. of Conductors Stapled ,��Romex Installed Close to Edge of Studs & C.J. 27. E uip. Ground made up w/Mech Fastners-Bond Gas & Water 2 Appliance Circuts in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circ. / / ga Cu or AI -Oven Circ. / / ga Cu or AI Insulated Neutral 0 Yes 0 No 31. Service -Riser Conductors & Ground -Main Disconect 32. ip. Clearances Panels -Motors -Meeh. Epuip. Clo . es Closet Light -Shower UghtSpa Light Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35 A.C. Ducts Insulation & Support Vent Fan, Exhaust above insulation r Condensate Drain & Overflow, Size & Grade NO 4,1 Fumance-Vent Access -Comb. Air -Return Air Ve 115 outle V^tticAccess & Platform if Furnace in Attic Date Card 871 Date Card B-1 Date B-1 Date Cana B-1 Date •40 j ._Walls FRAMING (Plans) OK except #s Sits Proper Materials & Anchors Studs -Nailing Spacing & Braces -Plates -Sound 2. a ' g Walls over Girders & Floor Nailing top in Walls (rat proof) in Stops, Furred Ceilings -Stairs -Chasers -Tubs eaders & Beams -Size & Bearing Date FRAMING (Continued) h/4f'C1Ling. Joist-Rttr Ties-Purlin-roff Brac.-Truss-Shting.-Rfng. Fire lace Ties or Type A Flue -Fireplace Throat clearance Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 1�a0. Bdnn. Windows or Exiting Doors -Sill Hgt & Dimensions 51. Garage Fire Protection Framing ropety Line Firewall & Opening Doors -One 3 -Check Garage 3rd Story, 2 Exits irriNidth-Headroom-Rise-Run-Landing-Fire Protection VW -Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Glazing Area -Glass Protection -Skylights -Plastic ea ails; Nailing -Bolts 60. ce Interior / Exterior Wall Panels Insulation -Walls -Ceilings , Infiltration-Wa[Is-Windows Date - - Card B-1 Date Card B-1 Date ,: c Card B-1 ate Card B-1 Dat FINAL (Plans) OK except #'s 63. Ext Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace; Vents -Clearance -Comb, Air-Conector- In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground. -Air Gap -Cooking Clearance 73. Elec. Outlets & Rece ticales at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr; Vents -Clearance -Comb. Air Connector-P.R.V. In Garage; Above Floor -Meth. Protection 77. Plb., Elec. & Mach. Equip. Listed for Location 78. Elec. Receptacles in Garaqe (G.F.I.11-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor 0 Yes 82. Following Instid./Drive 0 Yes 0 No/Walks 0 Yes 0 No/Planters 0 Yes 0 No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throught House 89. Glass Protection 90. Corrections from Previous Inspections 91.Gas Test -Meters Tagged, Gas -Electric 114 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy ¢ mpliance Certificate -Other Certificates Date Card'B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: t COUNTY OF BUTTE < BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES`` 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541'-'— >4 CORRECTION NOTICE )�-o6t'j L �, 60VNER L,,,,.PERMIT NO. A routine inspection indicates that the following violations of butte county"Ordinances exist at the above address and should be corrected. Please notice this office when correYti.ontof'work is completed. If you have any questions pertaining to this matter, or.need additional explanation, - = please conlact tis office immediately. f� .t vp oel�l' ,.. �.. 6 1fti /U Vt { Date -1-1 -'(Q t o Inspector--6/out REV 10/92 a COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 97_2392 PERMIT NO (Rev. 12/96) APPLICATION AND PERMIT ASSEUff1t6116�l, ZONCITY BUILDINGPERMIT OWNRARGARET FOWLER TELEPHONE SO. FT. OCC. BUILDING VALUATION 1152 R 69 OWNERS MAILING ADDRESS XY 462 U '908 8,316 CONT ftkNAME TELEPHONE 40 C 520 CONTRACTOR'S MAILING ADDRESS CONtWJTPN LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 71,044.00 ARCIdfiU E�Gfn7G LICENSE NO C21283 Filing Fee $ 20.00 Permit Fee $ 513.50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUILrgfDTRENT STREET L} b Energy Plan Checking Fee $ 23.00 $ CITY OF NZ BIGGS PERMIT FEE $ 579.50 LOT 11 SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 8 7-0056.00 USEOFSTRUCTURE SF J] Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 15.00 Each as water heater or vent 15.00 15.00 TYPE OF WORK New ft Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: MASTER IREXX # PLAN 1152 Gas piping system 1 - 5 outlets 15.00 15.00 Building sewer 15.00 19-00 Mobile Home I S I G I W 920.00 PERMIT FEE $ 136.00 ELECTRICAL PERMIT Filing Feel 20.00 Main Service OA OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.d License Class LIC. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ I am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUR OR ADDNS. ( & ACC. BLDS. SO 3.50FT. 56.50 NON-RESIDT MIC I-CUTCU @7.50 PSINGLE OWER APPARATUS OUTLET CIR. Ex. Occu OUTLET OR FURORES 20 Q t.00 SAL_ p .50 Ex. Occup. ouT TAPP AWoOEA. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 99.50 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the rs' cprovisions of section 3700 of the Labor Code, I shall rt chos rovisions. AV-%7�-Z AppOwner ❑Contractorgent An OSHA permit is required for excavations over 5'0" dnd demolition or construction yep of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating 1 5 -no Cooling Hood 6.50 Ventilation PERMIT FEE $ 65.50 Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ CONST. TYPE TOTAL FEE $ 926.90 HA2. D. FE � IMP FLOOD _ COF PARC PD HD _ ISS This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date _ PERMIT EXPIRES ON �2 Date ReceiptNo. 231124 $126.-00/231396 $800.50 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTM� NJ', OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - ov,California 95965 -Telephone (916) 538-754 PIpR T No. (Rev. 12/96) APP I TION AND PERMIT 3y ASSESSo ARC NUMBE S� 06 / ZONING^ ,t t BUILDINGPERMIT , OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION 5 MAILING ESS , _Z,Ow COM :,,S NAME TELEPHONE CO DR'S MAILING ADDRESS CON RUCTION Fireplace LENDER'S MAILING ADDRESS Total Valuation Is ARCH 14 6 f C NSE NO.% Filing Fee $ 20.00 Permit Fee $ ARCHITECT GINEERS MAILING ADDRESS Plan CheckingFee $ BUILDING ADDRESS r— 6 5 r t f� Energy Plan Checking Fee $ 00.00 649 a PERMIT FEE $ -S LOT NOa SUBDIVISION'S IONS NAME PARCEL PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF CY Duplex ❑ Mobilehome O Other SPECIFY Each Trap 7.00 1 Solar or heat pump water heater 23.00 Water piping 15.00 '"00 Each gas water heater or vent 15.00 TYPE OF WORK New 1K Addition ❑ Remodel ❑ Utilities O Installation O Other ❑ Describe Work: _[ G� �e % Gas piping system 1 - 5 outlets 15.00 )S, Buildina sewer 15.00 )5. Mobile Home S G W Q20.00 PERMIT FEE $ 3/ , ELECTRICAL PERMIT Filin Fee 20.00 OOOV OR LESS Main Service 20.OR LESS 23.00 �3_ LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000 of Division 3 of the Business and Professions Code, ( g ) and my license is in full force and effect. License Class LIC. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: O I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations ver 5'O" d ep a d demolition or construction of structures over 3 stories in height. CIP Main Service 2E TO ICCU000A 48.00 NEW CONST. OWELLINO DCS. so C�/_ 5' OR ADDNS. ( 8 ACC. BIDS. 3.5¢FT. J �v �J NEW CONS . MULTI.OLITLET NON•RESID. @7.50 •" FGwER APPARATUS 6 SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FMREs 20100 BAI_ so Ex. Occup. OU�TtEEDTSA AEsID•° 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE s MECHANICAL PERMIT Filing Fee 20.00 Heating S �Q Cooling Hood 6.50 Ventilation IKSC) 9'oD PERMIT FEE $ S,C-) Mobile Home Installation Fee $ Energy Inspection Fee $ /o Q occ CONST. TYPE _ TOTAL FEE $ g�� s HAZ. °. FEES IMP FL000 CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON are ReceiptNo. WHITE-O.D.S.-B.D. CAN Y -ASSESSOR PINK#SPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 , PERMIT APPLICATION DATA SHEET L O OWNER: r a�`�+ 19.71 Pr ASSESSOR PARC ER: 0 � V �.�1)—Oco I Proposed Building: 1 ' Co Building Inspector: Date: � �r r� At time of permit application, I was advised the following data must be submitted prior to permit proess' g and/or issuance: Date Received By 2. All items have been submitted.---------------------------------------------------------------------------- 2. Plot plans, 3/4 sets, signed by the preparer of plans. ---------------------------------------------------- 03. Complete plans, 3/4 sets, signed by the preparer of plans. --------------------------------------------- 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! --------- 06. Energy Design Compliance and supporting documentation. ------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. ------------------------------------------------ ❑ 8. Hazardous Material Form. 119. Manufactured Home data and installation instructions including Tie Down Specifications.------------------ J�F: sof$ © Doo, -------------------------------------------- - ----------------------------------- act fees as shown on the attached schedule. - ©� ----------------------------------- ❑ 12. California Department of Forestry plan approval/fees.-------- -------------------------------------------------- 1113. ----------------------------------- ❑13. Flood elevation certificate. --------------------------------------------- ❑ 14. Sanitation and plot plan approval Health Department. ❑ 15City of Chico plumbing permit. ------------------------------------ APlot plan and business license approval from the City of Biggs. ❑ 17. Planning approval for (A) Use: (B) Parking:. 1118. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- ❑ 19. Encroachment Permit for drivewayconstruction approval prior to occupancy) ( PP P• ------------ ---------------- 020. Pre -inspection for required. Request to Building Inspector on 112 1. Contractor's license information. (Number, Name Style, Classification). ------------------I------------------ ❑ 2 Workers' Compensation carrier and policy numbber. ----------------------------------------------------------- Ownerb -Builder Verification (Given to owner , = Mailed to owner ❑). ------------------------------------- 24. Letter of signature authorization. -------------------------------------------------------------------------------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- 026. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing'violations and/or expired permits. ---------------------------------------------------------------------- ❑2. 0433 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C. $--------------- Other: 5 I ti\ L'/ 2 11 r^ b1'1( ------- When you issue the pernut, process as follows Mail to owner, ❑Mail to contractor. ❑ Telephone and hold for pickup at Applicant: office. ❑ Deliver with inspector. Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Copy of plans sent o Health Department, ❑ Fire Department, ❑ Other: Date: Date:_ By: Date: By: (Date) 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Plans reviewed by: Date: Plans approved by: Date: Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. € n•�.r-..�.Sr�Yi*"�'s'p'n+ti ,A..nv:iye-., 75�tk.1•i.'ti....:7F i%cfi"r}a�i.!"„t ""r�'.'iF%e.�hA,m::.:?...:y, "'�`r... ., »:;.� h-_., ti ' y' -,.r.•'- . v:�.J e.. r ..,� ... �. �', i . � _ . ... i BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One Form Per Building) School District A.P. Number. Property Owner r� ,- ► C Q I Jurisdiction:';; • q / (C- 0 C' r Building Department No. City [ County r--- r' Property Location/Address Cv j Subdivison Lot No. Residential Development [] 0 Sq. Footage / �5 No. of Living MHI Addition (Group R) Units Commercial/Industrial Sq. Footage New Addition (Including Exterior Roofed Areas) Building Department Representative Date (Floor Plans reviewed by School District Personnel) District Identification No. �O School District certifies that UJ le%, —- (Applicant) (Street Address) (Phone Number) (City) (State) (Zip Code) has complied with the requirements of Resolution No. / by payment of $ representing square feet. As 2926 $ FULL MITIGATION $ ool Re # r entative Date Paid by Check # Remarks: Bank Number Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) ' feeformmk, („isa)dmm PROPOSED 3'BEDROOM / 2-13ATH RESIDENCE OF 1152. FT. WATER 20' TO METER --- 10' TO FACE OF CURB PROPERTY LINE WATER LINE 3/4" SCH 40 PVC 2" PVC UNDER DRIVEWAY FOR IRRIGATION SYSTEM a* as aa. M=--" m� am mm:4 ? % ) CL � =b 5lzr.. rr a �+ %1 a g N a Er �l d �Q m a s* a SO a a cr 5' SITE PLAN MODEL#11 S 2 TRENT STREET Continuous Fenci a to be 1 x6 6' high dog-eared Western Ced; NOTES 1. SIDE YARD SWALES SHALL BE PRESERVED. 2. ENTIRE FRONT YARD LANDSCAPE SHALL BE COMPLETED PRIOR TO FINAL INSPECTION OF EACH PROPERTY. 3. ENTIRE FRONT YARD LANDSCAPE SHALL BE IRRIGATED BY AN AUTOMATIC IRRIGATION SYSTEM. SOUTHFIELD MANOR BIGGS CALIFORNIA COMMUNITY, HOUSING IMPROVEMENT PROGRAM 42' m w No 4 BL Lot 11 465 TRENT ST. LOCATION OF TELEPHONE, ELECTRIC, & TV TRENCH ELEC. SERVICE TE COUNTY mhsT�R q y -22 7- 2392 FILE COPY STREET TREE - City Approved CONCRETE M LAWN ® SHRUBS SCALE 1 " = 20' OWNER: MARGARET L. FOWLER 465 TRENT ST. AP#022-350-061 12/4/97 0, Mir. "YC.1 1+C4:A.VT i ' 10 t _ _ r`�•2 T:�iyt .' .. ....... !" £ P t' 17 -; fig:' QT "J •�rY:Y.'1Mfw'.ssiaYti VZ.I..1ltlrw•'1.MdMM�hM �1NYwJ.� ygy j 7 i ° i Ile b;d �Z,i tI1M•[1.V1.1...eM+f/h".w1M«...IO.aMt'�V•)�./1M0•"�'ity.�.A /� ' �Xr �+t� :�.; E'�tli::c2a�,, ifrsRl•'2i$i1C„' T+•� �w.hr..r... ,.�.+.+.M+. �,w./...,uva.s.s.n..:+xw-a.of.•wreC.'aw..cww.+w.-.r.rt,=w..w Y'f'f-MgCl'fi11, `1 ( H r 57 3i3rtu' q CS YAb'*P' 3`AM .��•ri..i�{l�f�{fit i 3..%hi�! .j?, JJA?'fC{ �f sy!'.flT 1 +A.��" Ya ..Ar,,iiiV.; A:) LC'.rJLEF, joj Y'rf'vi!)2rj2,',iJ `� CA S i f April 22, 1998_ / BM1 Project No. 98R-018 01 CJ v Laboratory Testing Optimum moisture contents indicated below were based were evaluated using laboratory methods ximum density/optimum, moisture content tests performed by our firm. Moisture contents (i.e., ASTM Test Method D 2216) on field -obtained samples of the subgrade soils. Lot No Date Depth' Moisture Optimum %Over Result Sampled (inches) Content (%) Moisture optimum Content M �-4/20/98 y 0-18 21.2 17.5 3.7 Pass Pass 10 4!20/98 0-18 22.9 17.5 5.4 5.3 Pass -- 12 4/20/98 0-18 22.8 17.5 17.5 3.3 Pass 13 4/20/98 0-18 20.8 , 17.5 5.0 Pass 14 4/20198 _ 0-18 22.5 _ Conclusions Based on the results of our field and laboratory testing, house pads located within the ofgeotechnical 9. 12, 13, and - 14 meet the subgrade soil moisture content requirements investigation report prepared for the project. These pads should be kept moist up to the time of vapor barrier or concrete placement. Testing services provided by Brown & Mills for this project were performed in substantial accordance with generally accepted practices as they existed in the site area at the time our services were rendered. No warranty is either expressed or implied. 2 Depth refers to the depth of the sample below fmished subgrade. III