Loading...
HomeMy WebLinkAbout024-140-01924-14-19 - /'1 /1 140 o ALBERT W; SHIRLEY 2%-7-444.& ' as2s lAvenue l -Gridley ermit# 026-82-E eke --"—=-ch SF) +Igo 1 � A 0 1 - I _ I 1 HOMEwooa O LOOMIS OFFICE 3243 Rippey Road Loomis, CA 95650 �MARYSVILLE PLANT 5033 Feather River Blvd. Marysville, CA 95901 TRUSS AI (916) 65274655 Phone: (530) 743-8855 F 916 652 3860 F Truss Design Submittal `��'"'���N Designed By: Date: Technical Representative: Troy Moss October 15 2009 Troy Moss Office Fax: * All enclosed drawinqs are in alpha -numerical order Client Mike & Marci Shadd REFER TO APPROVED PLANS FOR ADDITIONAL NOTES AND INFORMATION FOR THIS PROJECT Plan: Floor Components: O Roof Components: Work Order # 0790809 Pro' ect New 0^C -.;A0%"^^ Owner:1 IM- 6 247 HigghREVISION: BP# 0-f--;, //I'D Site Phone: APN: o i q - yo. 6/5 Site Contact. Date . 2 •o FILE COP C Original Submittal 'I I • ° � a -c O Complete RevisionS o �r0. Iz O Partial Revision: Replaces individual racm Sving�C C4 & 0 Addition: Add to Original Submittal k.4 o 0 _.0 STANDARD BOTTOM CHORD FALSE FRAME DETAILS 4' 0" OC MAX. Man= Fulm NO SPL' Mt TRUE;$ �,'0ZS.Ir.N- IS SEPARATEFROgTillsDW VAIL: utt,:#2..Of- KTITE V061 FOR UtRYM&CJAL.F It FALSE _..FRAKc CHORDIS.4... 'USE; #3 OR :BET'PER :FALSE VIRWE WEBS;.. wboa V.midAL.S. Al. 4.,—o O;C.- SEE VEXT.OPTION, FRAUt *(E,SAn THE STRUCTURALRAL Z14606CHORD , iRg[S'Tj N 1MRWcAL-S M&t BE. LOC-ATED,-4m," + OR — 12' OF THE PANEL Pditm ALONG "gi, LtNGT-H APPLY REQUIRED ,'BRACNd ($U 'Bt W*) TO BE USED 44 UP 24' WAX;. SjJfftA9LY..:: .APPLIED TO 1W BOTTOM C�,Afloslts TRqSES (Olt JUT 1BOtrW t-ItOliV SEdaONS.,,dF. A TRUs§). I CONNECTIONS ARE THE SOLE PER THE LATEST VERSION 0 --tin W9 IIII"utw- 0�4" -wo Yw,ft 8,dlding C—p-.0 Group Incl .W"W =A ft!tnl Emh My. MO 63045 OF THE THIS DETAIL APPLI55 TO ANY PITCH, ANY SPAN, ANY TOP CHORD LOADING -AND. ANY TRUSS WEB CONFIGURATION FOR 24" O.C. Ma. SPACING- )M' IOPSF&�. CEILING LOAD., WITH THE EXCEPTIONS NOTED ON -THTS`-`SRE .' JDONOT USE THIS DETAIL FOR: 1. -STRUCTURAL BEARINGS UNDER THE FALSE FRAME (NOT PAR-ttTIO] '9.' INTERIOR BEARINGS AT ANY LOCATION ON THE TRUSS. 0, WADS IN EXCESS OF IOPSF CONNECTED TO THE FALSE In". 4:*.DRAG '. LOADS -CONNECTED TO THE FALSE FRAME. 5, T.Qp -dio9b.,:4 'ED'.' FAJ�SE FRAMES. SPECIFIED ON THIS DETAIL. I... VERTICALS SPACED APART MORE THAN PANEL POINTS (IF>4':0-)- & FALSE FRAMES ON CANTILEVER SECTIONS OF A TRUSS. I -SROP. App[m. p USE. AN ALPINE WAVE 20. GAUGE : 3%4 KW. PLM, Al HEEL CONNECTION: USi AIFINt `WAVE- -20' GAUGE ZX44 MIN. PLATES lir'FACH -END bk,- WK VERTiGitL --" PLATES ARE REQUIRED .0,11 )BOTH FACES Or aCH, JOINT. nr.,WP.Fnvn ., a - A 2vA::F'.kr_'lk `kR�kk'_AdTTOk`Cft -M Tcicr F?4kMB.GffOKU.. TO =- VLAUZU.-K] JOIN VERTICALS. TO 'ALTtR#AVNG END— O;C. -DESIRED.: -VERTICALS. MAY BE,JOINMB� !f CEioS2D :(64.20l -xl'.'37.5" NAILS INT I SACH S OF ":lUN'.'Y8RTT.CAL!.]3LO0 �TO EACH. FkCB-I�b.V i;PKL JOINT .IF , WITH, (4 U CAULS* bfi- sput*lj� t,.'Art,%tHr.b *wa #UdK TOM'. (OJNE� . - w 81 """ ,; - - i ee Bt �LIAR. 83- 200.9 CALIFORNIA HIP PERMANENT BRACING DETAIL FOR HIPS WITH STANDARD LOAD SECTION A—A OR' FI BUI REPRIE L`fIiv::CR[PPLE9 CK. :PLANE'' REOF'TRU8SES CRiI?'PLI; � COJtbfO.N SPACTNG ATHING. PITCHED AND SHEATHED o — CRIPPLE (C) SUPPORT LOCATIONS. CHORD AREA. SUPPORTS EXTENDED MEMBERS TO FLAT TOP CHORD (2' O.C. CRIPPLE SPACING SHOWN.) CONNECT CRIPPLE TO FIAT TOP CHORD AND EXTENDED TOP CHORD. USING: TO (2) 8d COMMON (0.1317 2.5 -.MIN) TOE NAILS WHEN BUTTED. OR (3) 10d COMMON (0.148•X 3. -.MIN) NAILS THROUGH FACE AEON LAPPED. Refer to detall BRCALHIPCRP for maximum allowable job loading and cripple length. SECTION B—B FiIP' 'Giit>yE TB GK" SEE CA TaP `I?UCU ERii'1C. 1 � FO$ Ji1CK "fYF?E vac;D. E CI 7,11VPiAL tKAMIr cr.:CglPp.rlivs sFcsA as'' o::c....(D) BUILT—IN FILL CRIPPLES S5 _S•P'OR2 Id7A[11NCI-#1f0 CONSTRUCTION, (HORIZONTAL MEMBER OPTIONAL) tr ouu.xa;s�arw u>saap:xiiii`.rant jCn LL., :PSF REF CALIF, .BRAC:1 4oc.,.go4s sStNa. was ka.fprl.attny; auCdeJ.+�iupdsa.�se'f:taa'w+a•re••"s.�m ut.r F .DA'1I; 1 . ,p,!�.a+«�w .tn ..an.. ctrPo�m..t ��. ,'.e.ata+..r:.. .n.n b.. n..nar ea+wra esu DRY�G BRiF 4CTi4J �/� .': pa . er 7N.lAl. !.�'..aa.rri ndw Y!t• l.r wsr. tzls.wtwe: Di PSE'-arroer�si,- ev>dema mv' o. wra sv e� rut�iwpu axmue+».: $atidlxi r/dfaL OruY(tm1C9}'ni:u.nl a .:.und. tor: d..t.wctmn ult '6++U++ 'L 1nr wA at L Bolding Carp-.—G—p lac up �1Q111s IO tW tftm td �A' htb LPL ar It .tN.}• .>•-11pi%.:.a.t.0J1. !1 l.p:!4 ..f l%A: N! 4+.(►b.11 t sw a-il.[.Oa;tkL 4r.x1q d1•.o�.s• �p..�..YY tsdhslr.:s7.1 lmas.td:.]u+Ca.�(dal. i�i3.`ia�{vca'Ghtlilj . Mr IA. trdr s.sapacal ..J.s s7ir.M tL. h td `pry .4C tin. sal. s.t ONQd1� b Ua .j ?0 3E?, ?.OQl� � FAQ: ttt-yR7f..n.,N.ece:ut'lc �•..<'....w,sxw..lgtt.dsdq;.aa�d.9CQ�'v..rlaw.,tev�. yEanh Chy. MO 63045 M A.R.' 1.8 2009 •s• x 36 0 no a NONE Simon 0 EK PFIA,1 J ONM 01 _0 ANSI SECTION A—A OR' FI BUI REPRIE L`fIiv::CR[PPLE9 CK. :PLANE'' REOF'TRU8SES CRiI?'PLI; � COJtbfO.N SPACTNG ATHING. PITCHED AND SHEATHED o — CRIPPLE (C) SUPPORT LOCATIONS. CHORD AREA. SUPPORTS EXTENDED MEMBERS TO FLAT TOP CHORD (2' O.C. CRIPPLE SPACING SHOWN.) CONNECT CRIPPLE TO FIAT TOP CHORD AND EXTENDED TOP CHORD. USING: TO (2) 8d COMMON (0.1317 2.5 -.MIN) TOE NAILS WHEN BUTTED. OR (3) 10d COMMON (0.148•X 3. -.MIN) NAILS THROUGH FACE AEON LAPPED. Refer to detall BRCALHIPCRP for maximum allowable job loading and cripple length. SECTION B—B FiIP' 'Giit>yE TB GK" SEE CA TaP `I?UCU ERii'1C. 1 � FO$ Ji1CK "fYF?E vac;D. E CI 7,11VPiAL tKAMIr cr.:CglPp.rlivs sFcsA as'' o::c....(D) BUILT—IN FILL CRIPPLES S5 _S•P'OR2 Id7A[11NCI-#1f0 CONSTRUCTION, (HORIZONTAL MEMBER OPTIONAL) tr ouu.xa;s�arw u>saap:xiiii`.rant jCn LL., :PSF REF CALIF, .BRAC:1 4oc.,.go4s sStNa. was ka.fprl.attny; auCdeJ.+�iupdsa.�se'f:taa'w+a•re••"s.�m ut.r F .DA'1I; 1 . ,p,!�.a+«�w .tn ..an.. ctrPo�m..t ��. ,'.e.ata+..r:.. .n.n b.. n..nar ea+wra esu DRY�G BRiF 4CTi4J �/� .': pa . er 7N.lAl. !.�'..aa.rri ndw Y!t• l.r wsr. tzls.wtwe: Di PSE'-arroer�si,- ev>dema mv' o. wra sv e� rut�iwpu axmue+».: $atidlxi r/dfaL OruY(tm1C9}'ni:u.nl a .:.und. tor: d..t.wctmn ult '6++U++ 'L 1nr wA at L Bolding Carp-.—G—p lac up �1Q111s IO tW tftm td �A' htb LPL ar It .tN.}• .>•-11pi%.:.a.t.0J1. !1 l.p:!4 ..f l%A: N! 4+.(►b.11 t sw a-il.[.Oa;tkL 4r.x1q d1•.o�.s• �p..�..YY tsdhslr.:s7.1 lmas.td:.]u+Ca.�(dal. i�i3.`ia�{vca'Ghtlilj . Mr IA. trdr s.sapacal ..J.s s7ir.M tL. h td `pry .4C tin. sal. s.t ONQd1� b Ua .j ?0 3E?, ?.OQl� � FAQ: ttt-yR7f..n.,N.ece:ut'lc �•..<'....w,sxw..lgtt.dsdq;.aa�d.9CQ�'v..rlaw.,tev�. yEanh Chy. MO 63045 M A.R.' 1.8 2009 ANCHORAGE AND RESTRAINT OF LATERAL BRACING TRPS:. IS. A DANGEROUS COND;ITLON FIG:. COW?R�SION;'!lfiD$ .•,.j'—TO i'REVEC(T TFIIS tl} Ot27'AND 4Mti -M FiFII.CJftta, cid L, 1.. t7GCF[CDNG:': RESTRAIN:' TFNE. r>A�:I�ar. ai2AGItZC1. i'F; : !.1 f�l� � C0I{f2NUt)US Ii1'F;N3/(L BltAC¢NG USE ;:MEIiIOD HONK .Ttt (=) 6Wl7rAIN0 SI ACMGI BUT' ! PSRK[Ts 1AnMAL DucKrlNG' GI! ALS ;!IEB-i &HBms AT, AINDTINGII'STRl1CTORALLY TIM, SAO1Ii(D: SQUND• umOU. SPP,ClM-.0 BY PRGPF:85IGIQAL . BBXIFDNG roB;.'iRli59�4- ENGIfIi�ER.;Oil.:litlC[i1TECt; FIG. 2 ANCHORAGE BY BN_m, MIN . DEI .R (OTHER ANCHORAGE PROVISIONS FOR OTHER TYPES OF WALLS). IIII autlai^0 Canpwmm Croup 1— Eanh Cly, M000045 ANCHORAGE (BY BUILDING - DESIGNER) ONTO SOLID END vALL - REnvAIINS LAMAL BRACING, THEREBY PREVBNLING REB BUCFIJ}NG, CLD COMPRESSION WEB FIG. 3A DIAGONAL BRACE RESTRAINT (DBR) WITHIN THE UNIT (3A & SRI DBR MAY TRAVE RS9 lwfm. THAN Toro TRUSSES, DEPENDING ON TRUSS HEIGHT. tat 'awa..at. ..� 3tICATIi[SiG; ` .9LQPS!?G GR V�RY7I �O:R; RF.r7 "NERi}CE3U :DltACNNNC. THE DRAWING BELOW (FIG. 3B) SHOWS HOW TO RESTRAIN THE CONTINUOUS LATERAL BRACING (CLB - f M). WHEN ANCHORAGE IS NOT AVAILABLE AS SHORN IN FIG. 2 THE DIAGONAL BRACE RESTRAINT (DBR - ) MEMBERS ARE 2X4'5, THE ENDS OF WHICH ARE ATTACHED TO TOP & BOTTOM CHORDS. THE DIAGONAL BRACE MAY BE ATTACKED DIRECTLY TO THE CLB OR TO THE REB OPPOSITE TETE CLB. USE THE SAME NAMING SHORN IN FIG. 3A. FIG. 3B :0(4 -J3 OR SM GRADE DBR NABBED tO:NSP SWE OF TO AND 40 AT APPROXIMP.—SLY M ` RPi'FiRVAL9:19 RCSW LATSi3A1i AITAGH ".. i.mss *�m . . (aj i.sa co►f�NiiR (G:fNai.x S- .RtlIC) Fi snn'.iMw�d'an. i- iayipi)r(y:rgyie: ia¢ou¢i.4. bi NOM.4raali:er}, b'k92.Z MAR 19 200.9 CLB WEB BRACE SUBSTITUTION T—BRACING THIS DETAIL IS TO BE USED WHEN CONTINUOUS LATERAL BRACING (CLB) OR T -BRACE IS SPECIFIED ON A TRUSS DESIGN BUT AN ALTERNATIVE WEB L—BRACING: OR BRACING METHOD IS DESIRED. L -BRACE APPLY TO EITHER SIDE OF WEB NARROW FACE. ATTACH WITH 10d BOX OR GUN (0.128z 3.',MIN) NAILS. NOTES: AT 8' O.C. BRACE IS A THIS DETAIL IS ONLY APPLICABLE FOR CHANGING THE SPECIFIED MEMBEMEMBER LEENNGTHH M REB CLB SHORN ON SINGLE PLY SEALED DESIGNS TO T -BRACING OR SCAB BRACING. ALTERNATIVE BRACING SPECIFIED IN CHART BELOW MAY BE CONSERVATIVE. FOR MDin= ALTERNATIVE BRACING, RE -RUN DESIGN WITH APPROPRIATE BRACING. T -BRACE L -BRACE WEB MEMBER SPECO?IED CLB; ALTERNATIVE BR1iClTffi • SIZE BRACING T OR- J BRAG SCAB : kkft" 2n -OR 2U 1 ROSY :m.. 1_eu 2X3 OIt m.Q -RO,," 27I8 2' 8X4 2fi8 ........ 1 hOpf 2X?k _.. L=SA'8• 2X8 2 ROWS, ZX8% 2 2X4{r) 2fi[I 1 ROW ea e 8 :ROWS T -BRACE, L-8'RAGE, AND, BW BRACO;J,0.. BE,. S.iME SPECIES AND GRADE OR BETTER 7EL�[ SLB Bm UNIIISS SP== OTHERWISE ON ENGINEER'S 6[iALBD 11ESIAN,, (�) CENTER SCAB ON WIDE FACE OF WEB. APPLY (1) SCAB TO EACH FAC£ .OF Tizu. ////T10 e�uaw�b. C?n+o�n+wmo Cdr. F.walmm: mo alms SCAB BRACING: APPLY SCAB(S) TO HIDE FACE OF REB. NO MORE THAN (1) SCAB PER FACE. ATTACH WITH LOd BOX OR GUN (0.128'z 3.',MIN) NAILS. AT 8' O.C. BRACE IS A M9MMM 8OX OF REB MEMBER LENGTH nu. 0 G7.W to 30,2m SCAB LL PSF dZEF PLE APPST. D% 'vSp- ;tinTE 1%1/04 bt 'PSP DAWC TiRcLT sus, OX09 LL PSP . rAC..... CIMG 2x4 WEB WITH WEB -BLOCK® REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWING FOR LUMBER, PLATES AND OTHER INFORMATION NOT SHOWN BELOW. PLATES FASTENING WEB—BLOCK TO WEB SHALL BE W3X3 OR LARGER. PLATE POSITIONING TOLERANCES ON i - B— BLOCKS SHALL BE PERMITTED TO BE VARIED UP TO 6 INCHES FROM GIVEN POSITIONS, EXCEPT THAT PLATES AT THE END OF THE WEB—BLOCK MUST BE WITHIN 6 INCHES OF THE END OF THE WEB—BLOCK. 2X4 WEB—BLOCK 2X4 WEB SECTION A—A: W3X3 PLATE;.�:-=-- 6" MAX. 0. C. (TYP.) 2X4 WEB—BL'OGK ft 0. C. MAX: BETWEEN W3X3s' (ADD 13:X36 . W3X3 PIATE: .. _ ..... ...._ NE EDED , A — — A W3X3 PLATE _a MAR 18 2009 J'(j/%' �(�. j . •_ m . mw.m".�..s d'wo.ia; , ..rm+�tw -r � wi... e.w:"i"a'.::i... ws �.. ' DtYTT' lj� �09 ( 1 �f e.*,. ■ltaq+nr �fcogrr.t rmd.°'. *n. a + ,fall Cui. c oTevF,ip ff+ .t rd ' � l -_'J` �7'i4.;+D 1W Turtt L14'�1 tl YL �.b dtW R�f� VM.•io� UNLJIa6 ASC .," ..kuoar o5 w of ua:td. yens..�� ow.. wx!h/ mmr.11ua.c ux,: G1R7lCr I3I B iK010 "1YPQRfit1� RiWI«Qi QQP'f p 7{Wt d�CR t0 rl�ElltdYlOK'�.'4�-�' ........ IIi Dctldk�y �+ CeaaO �*.+, aeil A.tl' cot b � tur .n aar.twnfrom uu, �,.iya.� a�a�arna�ms�»aye .gyp f.qv,., b Lw1e 16:,lean b wry! rR, nr Kr aL +xdaw:m.+:�w Jr: ' vBUTTtVNq cst+a uw d.a •alluiP+o +_ tWjldFJ ss�s.4 NaL �JOb' tai b �+e4 J�or �t tt®r. Dwf.Im�dae aLirtn s'Jw+ u�:m JttGf E�ii�. d 3 en .Wd 4sNkiE @-� •�' �d�c.L.e .Em�(.so. wl, pda�tonH ,uy!(c Alii !*���ki�bsb . t►+ .1kL:y�'1g� Qr/N�+ IR 4PHC/414 l fM.l� • Bir!n ;� MO S rt+i'-acosa.vll.eq[�aait Sfll's...lpRnd:mtn; Vitra, r!pa��w1,�a�'SR,.. �+�+.r�e�h,;kr0 ..� ' ^ 4 COUNTY 81 111 rlr I anti_. I/ WFC ' 7 ! y�" L d`dq:.�t1� _' END . fAWRAFT'ER 3TA.MDARD D:EJVA ('CA:LIFORNIA :S'T'YLE 0P Tf0NAL • EXlTENSIQ'N TRi1S5 . PI�'�ES' -ANA LUMHEI2: AS SHAWN OR...PEIt` 3X: INAIVIDI7AL TRUSS D�7$ICN�. �' 4 3}C4 • = • � 7 : al'- —7►_ : • IIN:(•):irilll•)l:u=Hrbl GIRDER:CHOW JACK TOP. .CFIIRD... R�JNS 61 `R: QIlRD1;R. 'TOR' 0 D (91 Yd1- (0 i:4(t x5 ar f4w 771d (0 t46'�Gtt 1 or 14d (Q't s� 6 Stld (0:188 SciL 6 BAILS. TIYIi0t34H JACKC WYO "HOUGH: 7:Id�ue�w .C; mm. q tlR par glolml TOTS^ r.=%R lop OWIM. To& tAL's OR'.AItE'attASi'; '.tLAI_ OB':AmtriTIS usdkuhctL� 0311. u7cl cu pww"ra`-ILlxur: cA�ALoa:.. pun ILA1m 'O Au= . p15SIGN gga�R 10 PSP NON CQ r BOTT014 (iiORD LIV2 LOAD. Zi7RY[k:IOACTAB AOR 90...1dPEfGAT:" IvpgGRSPRixFtt�t3 OT! oT NO I70INT LQAbff�.�.X•;clr��AANAILL uN3 RM MI`AWiHDOTE;OAL..D>GNO,� i STAI(DARD JAC(C8 RS +a`4Y7Gi0'a' PatD 4714 74AtCflf Mkt 11pfC1 QA 41i:•'!IJ(7,BSr ( now. a . ': Irk a¢ f•k1�..kKa ia,l+�s7a�ilc• n•a l au 1111T�ana I/)/'lll—'►///(// eE37+f• •Lara fa Taniwinl latm7. �wltiaf o1 gab• i watlacr ba'Y N 71MiN7o 7di r.•vdra{ cat. pya p. mar. (nt� -�m°o9�r�xf`� ryNNazt wRY pr isffio 0catts Y8 timta<futmK 1N W -0- a. -O. I UMBER. REQUIRE)t9tfM JACK :Top.. C)iOAD: Wii pB OR BETTER DF -L GREEN, /1//2 OR BETTER CAN S -P -F. i2 OR- -BR; M HEiSpM. OR 165OF MSR ANY SPECIES JACK. BOTTOM cRoRo.; 2i4: f2 OR BETTER ANY SPECIES, OR 105OF MSR ANY SPECIES -TOP. CHORD _LENGTIC-MAY'-VARY FROli'.8' .MINIMUM TO 8'-0' MAXIMUM. WITH EXrf.NSPONS SUPPbRTED AT 48 O.C. M XDIUiM BEYOND. HIP GIRDER. TOP; CFLd)tp `MAY BF. SPtdGEp A3 SHOWN; ADOVPJ THE HIP GMDER ONLY. -DOTTIOM C11GRD LENG13V MAY VARYl.-Odw 4"' 1 mniu M TO 8'-0a MAXIMUM. 00 . of spiuCg'.,THF BOft6W, CHORD TOP CHORD PTICtI MAY••VARY FR QM 41$ lilN[S(`tM TO 8:12 MAXIMUM. 8(YMW CHORQ PITCH MUST.BE. FLAT (O.lZ).: SPECIAL USIGr%" RFQUIRED `FOR TKISSE9.41TIt . OVERHANG LONGER THAN SPAN LE?('TIL T its pFTA2L, ?Ai?PGdEB 'lO :4S DFCRBF� HIPSEC:'OKLY. f CK TOP CHORD UST BE SINGLE EVELED OR OUBLE BEVELED L+K p^�y�..uLt+ONp Ma.([�ap2p71.na1 b ivgaed6q M a•a.u•. 7faa. 7L7a awp. tklfk!'Xp Gwm... Afl Om,0 MIQ. tS7 'r cif ii iWa<'aM irks• iR. a� f{Ir i4. �i,krbally. WfLLa{, �ypr•• YwYr( r ►h�R.d`.axuwv 7rfnCa eoek.ulal! 01.0 kiti .ei•4• N �(Itln4q (7rJ1/•/A •frll rrp QUa n/p/ p(/11111..n.p�L,.�l•. ij* old" 7.,�aa� t a• tf't.w., pirlmk7an.0 d— — w — hW ow•E'+ A •*.J io:YW Yiv ;M eb'+ar,Tt�"lo�dlgi4N2�a p lire VZ%.k d -gt ti{ f�q•a/l Y a•N for tL.+rl+c wrmb�4.14 iet.w 1'b• Ysita.aQ s me mi.'wt iu..•1ws•1 hr rf �ouur r W n+�eerfdilQp tl th akllair• D.rnie.pa air t af•c. 'q: e k i atr' a e a1os� to a0a'awaraay aw I t , .. y .w.c ,...srxdss.0— W. —A. ,•ra+.• HIP GIRDER C�RNER JACKS / TIDE vl END JACKS END CORNER JACKS MAX. 8'Or MAX. --�{ PSF REF END JACK H� TC LL 20.00 9 TC DL 14.00 ID i DL 0.00 PSF PSF DATE 1/1/09 DRWG EJRAFTER0109 LL 10.00 PSF W. 44.00 67927 cn PSF IV,FAC. 1.25 Ane 30, 2009 CING 2-0-0 cm\ \ . • , `OFCg,\ ° �_ MIlR 1 Q ?M01 e TRUSS PLATES AND: LUMBER AS SHoww. .I TER' INI' I DUXL 'TRUSS .DESIGNS. END JACK/CORNER STANDARD DETAIL fMONAL ` XTENSION, :. 3x4 .A. c r�D 3X4 • :HLP" T E �CFIORDS °(T0 R) . (90�fTtD LACK TOP CHORD RUNS OVER GIRDER TOP CHORD. (g) 10P 0 [4H oY 1:i iye'Ia,14a"��} az 't6$ os+is`is b�! �S; [T1Yi0(Utif1 CAGY tiffi ID(7Q. 1aa (a)�Yoa� XMW�:crRa� Iaq�".ciaaRDl rad= sto�aan)t:.JAcg . �n: txlu 2tAIIdip . nR At10�UAti4 aeauEs:1LECIaANtCAI. xANapt NAn14a, att 4aa¢uaa i/SsgidtRLeL }tti'iQFR PSR 1[Ah'UF.'CA7JlgC. p£R.iUilUt '.CAtAJAGL, - uiartGrr �x co ps>a •;toy aD r �rn��aDTrol{ aR:GRD Ltv� coAD. iPli;p tAAD&D .VOR. d0. 6iPHf �i49�EIXROSORP G :.x:�-x:oo 1(A)O]IVY. C(P` i7 i.QriA8. ]LRC>3ANI�. . U HVAC, SPRiH)tLti;RSr 0;';; OTHER TTEHdB CAU5[IV ..ADn�1'[0_ Aj„D�iHSTbN'•THR STAH'U11E{D lA?JKS ARE • Aid,OIFEA,, i�OUi'' iUMBHtR RTiQT11REMmm., . IACF%1. P i'J.TORD R'x4 '(!2 OR 8.£TIER J3F=G CRCFIi... i%SII OR BUM-3i�C�l1i# J2 OR BETTER HFA 178, QR; t850P .)ISR ABY; S1PECIES ' H4K,HOMPMY:GHORp 2i4, 1-Z'OR berm ANY`fiP CIE5 OR•.,t;850>' 1t9R; ,1NY :SP! C[R; rOP dMORM-31"Ram HAY VARY'`FRO ti W m1(U1t TO.?8 0 E SOP.-OHORD {XYEN9(Ott'SUPPORT6D AT 48 ..,00 UAl0MAk DEIOND HTP:';GTRDERS.ldd 0-,148'x37 OR'T6d (OAWi3.52,.NAW iiQTTObi GHORD:'LY1`GTR"IIAY VARY .FROWV 11NOiUM TO,B',-D 11AMICUI . 4. NOT S(?1JCE 7iiE:BOFtOSt.dHORD: OP GETORD PffCli HAY• -VARY PRO1( 4+t2 kR1G(UY1 1,0 :812 1U1X11(Uit, �oI't01t OHORD :PLTCHt ',MVST tat ' FLf (0 1,2)f iPZCLLL.DES(GN"REQUIRES'. FOR SRV9SE9 KITH .bVF1tt1ANG :CdNCRR IHA1V_ SPiui LQNCTH: WS-1)1xfAE ;AP.PLIES TO"43 'T)f10REEV 1i1P3t'F: 41iCY;_..._.. --• - -_ a o T K -- - JACK TOP CHORD IUM BE SINGLE BEVELED OR DOUBLE BEVELED 61-0' JACK (ONR RAfT10t ONLY) _... - «vlu o» ma lm roves ALL a710 mr t® as++ 1 hp.A .ttr+m. sir. r hkYVLF a.aalr. lay.h[. 1..1.11!•a .M �• aft M d'I STiCJ(. Qh�dL,i.:iM9"iml... ” , hSnrtiR b �1 u . TRS) M .idf ifs Rb 1" Mfv�Y . ,..tee.. a�..a".. Wa ...,we.�� �..w s�..t bM— � Aa r...:=. .II -Ml IA .rum .i lda:a /. r•r.�+ 1.1..1 L.w hr a rra�.11a.. ratrcrtriA i� ro>ticsat or" or Tw =aa= va wnuwfmr cwn m 7'I►.auemN't.p.�.y ..I..d;.� a.d OTV§W) d.a .4 r��11y� n,ev.+ im.ay+. antq lic: paw. t. OWid�uw. +..r.a... " Tr L • arlwtaa mal a f.p.y. m.l.nw '.nrnaa rr1L..n --w 01100m rr �urnn tarn_ 'Kob pr—'. ...k ft- of w. Mruk.... a....b— a SW t wAl (Ie ;4h4,ftMlmad�P ry. df7MaY. iMrt: fhb 1ic.s'equ t:, f w� wtW01V .. aw .f YL e.y.Mt M .y W1NIy 1. ww>�mat{T w. a..la� w 1 rr .lur . a Ei+n,'Cn. NiO,�SMS' rflt�, •r.,:�ik:� �°'�c ....Ip.no..; fl�ri• ...wowo.4rov.: mc:....loow..q HIP GIRDER SI E CORN r? jACKS N' N'D .JACKS END CORNER JACKS aa• rAz 8L0" MAX. N9 TC LL 20.00 PSF REF END JACKS 0"v 4 TC DL 14.00 PSF DATE 1/1/09 C HC DL 0.00 PSF DRWG EJCORNER0109 hhh ` r m C LL 10.00 PSF X927 OT. LD. 44.00 PSF.Xr.e 30, 2009 • DUR. FAC. 1.25 lull r€ 1 SPACING 2-0-0 ov MAR 18 GABLE DETAIL FOR LET -IN VERTICALS GABLE THUSS PLATE SIZES RISiL12,t0 dPi)IOPOfTE,:tl: OAIfB: RP1itl ti1lt' -ynN11jU1N PLAS'E�:&F.L.L3 ►0.fi::VERTNCAk Jl'L1O 01"L6tt"Tr7 r:(q PItKG.;Tt2tt8 ,JS7571Qtt'.Ifl�i Y'I'Ai{ D�tJM WED 'A" IYEGL ErATIZ ' • Q CADLr VC311ICA4'-P.tATy`4. OV6iN1kr,:USC .A Q8L1t&kP6AXE' TBATR9. COV2.T10i 'TOTAL ARLA'•0K: 'TI(A-' OVrRLAPPEDPi;=, '.TO SPAN TIM TO. Ta61i0?PJi _ (%.X.- PROVIDE CONNECTIONS POR UPUFr 1PECUTED ON THE ENGUMM TRU33 DESIGN, ATTACH EACH Y REDNTORCING MlMB= WITH END DRIVEN NABS: 10d COMMON (0.146'1 3, J00 NAIS AT 4' O.C. PWS (4) NAILS IN TOP AND BOTTOM CHORD. TOENADM NAIIA: Lod COMMON (0,148'x3',1@0 TOENAILS AT 4' O.C. PWS (4) TOMWW IN TOP AND BOTTOM CHORD. THIS DETAIL TO BE USED WITH THE APPROPRIATE TIW GABLE DETAIL T'OR ASCE: WIND LOAD. ASCE 7-98 GABIE DETAIL, DRAWINGS A13015980109. A12015980109. A1t0161149109, A10016980109• , A13090980109, A12090980109. A1103098010% Al 109 ASCE 7-02 GABLE DETAIL DRAWINGS 115016020109, A12016020109, A11016020109.:.i�1Tm Q201 �Ot„': 1b9, A1303002O109L A12030020109. A11030020109.,AL1., 26t: 0 A1440R , tl1D9 ASCE 7-06 GANE DETAIL DRAWINGS A13015050109, A12015060109, A110t606010f1 A1__ .Q60 ;\1N�i :109. A13030050109. A12030050109. AII050060169 Al t ,ALA 50179 SEE APPROPRIATE TTW GABLE DETAIL FOR MAImN1E• .. UNRXWMRCED GABLE VERTICAL LENGTH. rrrr{{ 0 'T' REMRCEWENT ATTACHMENT DETAIL 'T' R�Oli;7!@• T 1tLRR9HC[p6 'TGE2fAll:, �'Qik= 'VOW'' To CONVERT Mid V TO Y REDR'ORCING MEMBEPA MULTIPLY Y INCREASE BY LENOTH (BA= ON APPROPRIATE ITV GABLE DETAIL). HAImorm ALLOwmx Y REMRCED GABLE VERs= UXGIM 13 14' FROM TOP TO BOTTOM CHORD. IEB LENGTH INCREASE W/ "T” BRACT WI(D,=BPGED' ,.7t.:P.�W' AlM'.11Zti '1LDt�::tT},' .,iNClitA 149:"Ul!1T "2n1..... -•10.5'.. 10: !'; _ 60. x' t20,1a33i •2aci' a J 130 MPH. .: 2iti........... 10'. x "40-x ib ipr 9' .30'.11 100ll & 90 90; 45 R;;dt_.. E@ S <10IIT' 24': i9O'X EXAMPLE: ASCE WIND SPEED - 100 MPH MEAN ROOF MGM - 30 FT, Rat - 1.00 GABIE VERTICAL - PA' O.C. 3P 03 T RlaMRWG MEMBER SIZE -2X4 ?' BRACE INCREASE (MM ABOVE) - LOX - 1.10 (1) 2X4 V BR10E 1ENCMJ MAXIMLYM Y REINTORCEiI Y±AFit.Pr:.V TFfCAY,' LL✓t:G'T}1-. 1.10 :-9' -WARM*- RM AM MUM NL aom OF T a ri r-�. aLr- V rl .. � i +ti.,u1::.. 1. , u .-- •" � Wa am 6�++b. cm= hd nb - a •R r WVW .� .Lav:p.A'1')✓ 1 .L Ofl u.. n..u.— .a.o..'r. a...tA. a..ma .= W_ w nays. �.. m / / a.0 r..w� ...a a.6 r... ...v.b rw.A 67927 m 1111TY .?.0 1.. . Lt.... ft rel re�.l .."f-ftw - .r. r.n >.... r.rba rw.u.a rr 1 n..ew. as � s+. �.. or 1.�'. �.+.w� rr � �... � .,.. � U.�iPG C.k3.L%�T•�.V�:1:()$'.� -004mmRf- �a� ow or = 6mw p aswlanat CWTUCM lune 30, 2009 a+u.a a...� fie. p�pp) yY ..t M GY M q ..olds- 6a W. Binding Cana WtZ GMP Inc -W /0.. b x.61 uM b� r .rt��rs. vY 7R a< O�.M4La. �W. F ��Oa • r.r:,a .f t-- MMW ..-Lehr p,t- .n .d. w 80^6AOU TWA 11M Am uea oW ar/iN. MAX TOT. LD. 60 PSF° L obi AM* wl. to ON& ft- d h... p. -M - r........ W � ,a0d 6Lt�h..: J�.' CIVI � �` �FWM %.�Ie.--v .vas.. aP'air «�. °rte lr wl'k' • '9 QQ`� DUR. FAC. ANY ..r-mH� .t u. 6.rP , o. Alcor til I I— a � �F (. r , E.M City. MO O.101s In-atoa: ...n.�a• •••.ror.�.�iru ....s.rrLw.s.••a slc ...�I.L..a MAX SPACING 24.0��..... R.(.._,jl. .,... mop i A 9nno .# AD ! v e ASCE 7-05: EXPOSURE C T COMMON RESIDENTIAL GABLE END WIND BRACING. REQUIREMENTS - 'S , ZFFENERS- 100 MPH, 30FT *MEAN_ EGIT; ASCE ?---.O&l. CLOSED BLDG, LOCATED ANYWI-EEIZE IN ROOD', EXP C. Kzt = 1.00, WIND Q'PSF,*ATIlBC DL=5.0 PSF- 1ATERM CHORDBRACING -8R&,ayME; 'CN: T14 ? TOP. COMNUOVS ROOF- S 4TMd' -00. DtAP BPT; CONnVV 9:1 CEOANO" HRA04 SEE,E.NGINEl,0XS ' SEALED. I)ES1GY. REFERENCING THIS DETAIL TOR , LUMBER RATES,, WO"MAER INFORMATION NOT SHOWN ON TIUS" D -ET NAILS: 10d COMMON (0.148"x3") OR BOX (0.128"x3",MIN) NAILS OR GUN (0.125"X 3.".min) NAILS. 1) H H LESS THAN 4'6" - NO STUD BRACING 9BOOIRM H GREATER TF.IAN'4'V' TO -776'!jK LENGTH I ov - ib ., t -!A, md 8tir-PJ�Adk AT, MID-HEIdt t- AND; TO TiO_ OF',` D'IAPHRAG'M I PHRA'04" EVEky'713 0" (SEE ;D REFER TO..DRikWl 0:*'& 99300). H TO STIFFHACK WITH 101) ,BOX OR. GUN f ATTACHED TO EACH STUD W/ (4). 10 D BOX OR GUN (0.123" X 3", MIN.)'NAILS. I"= (two cm. -P -MR Z =Rr" .. & =.Zjr, TC LL Fir TC DL P50 REP on! -,mu= DAIS: .�IlIDD OF= Wmu P97; DItWTG Wtp-ropolpq :f I11T[o- ito" BC DL BC LL to :c#YAg, h:wiw.R eat 111N, MI Of uk= tarxzpow t -w 6- TOT. M. Psl*. Blt 1DUR. FAC. I MAX SPACING 24- u1i j; Vi Job Name: Shadd / New Residence Truss ID: D1 Qty: 4 BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 Web bracing required at each iocation shown. UPLIFT REACTION(S) : 1 3- 1-12 1250 3.50" 1.s0" BC 2x4 DFL #1 ® See ITWBCG's standard details. Support C&C Wind Non -Wind 2 33-10- 4 2586 3.50" 2.38" WEB 2x4 DFL STANDARD Designed per ANSI/TPI 1-2002 1 -209 lb 3 51-10- 4 614 3.50" 1.50" Refer to Joint QC Detail Sheets for This design does not account for long term 2 -244 lb BRG REQUIREMENTS shown are based ONLY Cq factors and Rotational Tolerances. time dependent loading (creep). Building 3 -160 lb on the truss material at each bearing THIS DESIGN IS THE COMPOSITE RESULT OF Designer must account for this. This truss is designed using the MAX DEFLECTION (span) : MULTIPLE LOAD CASES. IRC/IBC truss plate values are based on CBC -07 / ASCE7-05 Specification L/972 MEM 14-15 (LIVE) LC 24 IF THIS TRUSS IS CARRIED IN A HANGER, THAT testing and approval as required by IBC 1703 Bldg Enclosed - Yes, Importance Factor - 1.00 L- -0.38" D- -0.28" T- -0.66" HANGER BASED ON 1.5" HANGER FOR and AN and are reported in available Truss Location - Not End Zone EX.WB DEF CRI 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY document ESR -1118. Hurricane/Ocean Line No Exp Category -'C IN MEM 11- 1. OR S: CARRYING MEMBERS. IF 2.5" GUN NAILS ARE Loaded for 10 PSF non -concurrent BCLL. Bldg Length - 72.00 ft, Bldg Width - 73.00 ft CRITICAL MEMBEII FORCES: 9 9 7c COMP. OuB. / 7EN5. Duz. Csi USED, THE HANGERS MUST BE RE-EVALUATED Loaded for 200 16 non -concurrent moving BCLL Mean roof height - 14.49 ft, mph - 85 1-2 -1844 1.25 / 165 1.66 a.41 (BY OTHERS). Mark all interior bearing locations. ASCE7 II Standard Occupancy, Dead Load - 10.2 psf 2-3 -1689 1.25 / 168 1.60 0.48 Permanent bracing is required to Install interior support s) before erection. Designed as Main Wind Force Resisting System 3-4 -1197 1.25 / '42(l.60 1.47 revent rotation/toppling. Refer to PLATING BASED ON GREEN LUMBER VALUES. - Low-rise and Components and Cladding 4-S -1176 1.25 / 204 1.60 0.38 P 9 5-6 -84 1.25 / 281 1.25 0.32 CSI and ANSI/TPI 1. 20 psf Live Load applied to bottom chord in Tributary Area - 111 sqft 6-7 -54 1.25 / 246 1.25 0.61 accordance with IBC/IRC requirements for Vertical In exposed to wind: 11- 1 •. 7-8 -72 1.60 / 964 1.2s 0.74 attics with limited Stora a having a clear ----------LOAD CASE #1 DESIGN LOADS ---------------- - 8-9 -434 1.25 / 116 1.25 0.49 height >- 42" and clear width of >- 24". Dir L.Plf L.Loc R.Pif R.Loc LL/TL 9-l0 -731 1.25 / 142 1.60 1.53 9 TC Vert 74,00 1- 0- 0 74.00 - 37 0- 0 0.54 BC Co!' 11, / TENS. WR. CSI TC Vert 58.00 3- 0- 0 58.00 52- 0- 0 0.69 11-12 -23 1.60 / 59 1.60 0.42 TC Vert 74.00 52- 0- 0 74.00 54- 0- 0 0.54 12-13 -142 1.60 / 1727 1.25 0.67 BC Vert 16.00 3- 0- 0 16.00 52- 0- 0 0.00 13-14 -78 1.60 / 1536 1.25 0.97 Type... lbs X.Loc LL/TL Fastener 14-15 / 499 1.25 0.95 15-16 -817(1.25)/ 166 1.60 0.89 TC Vert 0.0 3- 1-12 1.00 16-17 -119(1.253/ 365 1.25 0.66 TC Vert 0.0 51-10- 4 1.00 17-18 -106(1.60 / 651 1.2S 0.83 BC Vert 40.0 24- 0- 0 0.54' WB COMP. WR. / TENS. DUR. CSI BC Vert 40.0 28- 0- 0 0.00 1-11 -1213 1.25 / 226 1.60 0.14 1-12 -135 1.60 / 1758 1.25 0.71 2-12 -2S7 1.25 / 79 1.25 0.04 2-13 -276 1.25 / 117 1.60 0.26 3-13 01,60 / 296 1.25 0.12 3-14 -616 1.25 / 130 1.60 0.66 4-14 -295 3.25 / 141 1.60 0.25 5-14 -10760 / 1185 1.25 0.48 , 5-15 -1138 1. 1.25 / 130 1.60 0.53 23-0-0 2183-0-0 6-15 -255 1.25 / 98 1.60 0.22 '1 2 3 4 r5 6 7 8 . 9 10 , 7-15 -S2 1.60 / 1726 1.25 0.70 7-16 -2210 1.25 / 171 1.60 0.82 8-16 -1079 1.25 / 139 1.60 0.39 4.00 8-17 / 460 1.2S 0.19 9-17 -341(1.25)/ 140 1.60 0.09 6X6 6X6 1�.. 1.5X4 1.5X4 �! 4 _ 5X6 - 1.5X4 8-1 -13 3.5X4 5X6 9- -11 a ri.a , 3X8 I SHIP 1-K1 3 2.5X6 11 2X3 6X63X4 6X8 7XP3% 3X4 B3 0-7 13 aofESS I W:308 3D-10-4 W:308 W:308 Q Q R:1250 R:2586 R:614 U:-209 40#1 40#j U:-244 U:-160 3-0-0"-49 0-0 T fn STUB '11 12 13 14 15 16 17 16 .6 927 N a All connector plates are Trus"I 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for NS 20 ga., "S' for SS 18 - . ga. es a Alpine; or preceded by epo for nrXpositioned 20 ga. or "N" /or 16 ga. rtew stud positioned per Joint'Detail structural p Circled plates and false 10/16/2009 free plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural pLtes (or staple). 268 - Homewood u5s Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUSt: Mike and MarciShadd (TCr4 b This design for an individual building component not truss system. It has been based on spedficadons provided by the component manufacturer DIR: Dri ve_T_0790809_L00005_J00001 0000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility Dimensions g po M rs assumed for dimensional W0: Dr i ve_T_0790809_L000 are to be verified by the component manufacNrer and/or building designer prior to fabrication. The bolding designer must ascertain that the bads that the l DS n r • TM #LC = 81 WT • 348# 9 T R U S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf $nowDu r L=1.15 P=1.1 S ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the mo'sturecontent ofthe wood toexceed 19%and/or cause connector plate corrosion. Fabricate, handle. Install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reporb' available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 "W Building Components Group, Inc. 'ANSlrrPI 1'. WTCA V - Wood Truss Council of America Standard Ossil;;n Responsibilities.'BUILDING COMPONENT SAFETY INFORMATION'- BC Dead 8.00 psf O.C.Spacing 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) o located at 583 D'Onof io Drive, Madison. TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street NW. Ste 800, Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 3- 1-12 1325 3.50 1.50 BC 2x4 DFL #1 2 35- 1-12 2568 3.50" 2.36" 2x4 DFL #1 & Btr. 11-14 3 51-10- 4 574 3.50" 1.50" WEB 2x4 DFL STANDARD BRG REQUIREMENTS shown are based ONLY Refer to Joint QC Detail Sheets for on the truss material at each bearing Cq factors and Rotational Tolerances. MAX DEFLECTION (span) : IRC/IBC truss plate values are based on L/973 MEM 14-15 (LIVE) LC 24 testingg and approval as required by IBC 1703 L= -0.39" D- -0.29" T= -0.68" and AN and are reported in available EX.WB DEF CRITERIA:L/120 document ESR -1118. IN MEM 11- 1; T= 0.00" Loaded for 10 PSF non -concurrent BCLL. CRITICAL MEMBER FORCES: Loaded for 200 lb non -concurrent moving BCLL TC COMP. DUR. / TENS. DUR. CSI 9 1-2 -1985 1.25 / 171 1.6o o.a1 Mark all interior bearing9 locations. 2-3 -1973 1.25 / 181 1.60 0.48 Install interior supports) before erection. 3-4 -1399 1.25 / 156 1.68 0.aa PLATING BASED ON GREEN LUMBER VALUES. 4-s 1380 1.25 / 217 1.60 0.36 20 psf Live Load applied 5-6 -323 1.25 / 109 1.25 0.28 P pp ed to bottom chord in 6-7 -303 1.25 / 9s 1.2s 1.42 accordance with IBC/IRC requirements for 7-8 -73 1.60 / 994 1.25 0.57 attics with limited storage having a clear 8-9 -295 1.25 / 226 1.25 0.43 height >= 42" and clear width of >= 24". 9-10 -612 1 25 / 126 1 25 0 53 BC COMP. DUR. / TENS. DUR. CSI ll -12 -21 1.60 / 59 1.60 0.35 12-13 -152 1.60 / 1862 1.25 0.57 13-14 -92 1.60 / 1712 1.25 0.85 14-15 / 672 1.25 0.93 15-16 -854(1.25)/ 160 1.60 0.84 16-17 -227((1.253/ 223 1.25 0.65 17-18 95 1.25 / 539 1.25 0.82 WB COMP. DUR. / TENS. DUR. CSI 1 -ll -1288 1.25 / 231 1.60 0.15 1-12 -144 1.60 / 1896 1.25 0.77 2-12 -280 1.25 / 98 1.60 0.04 2-13 -257 1.25 / 116 1.60 0.24 3-13 0 1.60 / 288 1.25 0.12 3-14 -598 1.25 / 131 1.60 0.64 4-14 -297 1.25 / 142 1.60 0.26 5-14 -106 1.60 / 1180 1.25 0.48 5-15 -939 1.25 / 112 1.60 0.43 6-15 -299 1.25 / 123 1.60 0.26 7-15 -74 1.60 / 1798 1.25 0.73 7-16 -2164 1.25 / 178 1.60 0.90 8-16 -943 1.25 / 119 1.60 0.95 8-17 -8 1.60 / 454 1.25 0.18 9-17' -380 1.25 / 149 1.60 0.10 Truss ID: D2 ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS;CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). j Permanent bracing is required to prevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. 23-0-0 26-0-0 1 2 3 4 5 6 7 8 9 10 4.00 -4.00 6X6 1.5X4 1.5X4 5X6 6X6 1.5X4 3.5X4 5X6 UPLIFT REACTION(S) : 3X8 Support C&C Wind Non -Wind Cust: Mike and Marci Shadd 1 -214 lb This designIs fm an Individual building w specifications provided by the Component manufacturer B msions not truss tem. It hes been based on 2 -243 lb ® 3 -156 lb WO • Dri ve_T_0790809-L000 ' This truss is designed using the 2.5X6 CBC -07 / ASCE7-05 Specification 6X6 Bldg Enclosed Yes, Importance Factor = 1.00 _ O_ 3-13 Truss Location = Not End Zone 1 Hurricane/Ocean Line = No Exp Category = C Bldg Length 72.00 ft, B3 = Bidg Width = 73.00 ft Mean roof height = 14.49 ft, mph = 85 W:308 R:1325 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System #7W Building Components Group, Inc. - Low-rise and Components and Cladding R:574 Tributary Area = 111 sqft U-214 Vertical members exposed to wind: 11- 1 U:-156 --LOAD CASE #1 DESIGN LOADS ---------------- H Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 1- 0- 0 74.00 3- 0- 0 0.54 TC Vert 58.00 3- 0- 0 58.00 S2- 0- 0 0.69 TC Vert 74.00 52- 0- 0 74.00 54- 0- 0 0.54 BC Vert 16.00 3- 0- 0 16.00 52- 0- 0 0.00 .Type... lbs X.Loc LL/TL Fastener TC Vert 0.0 3- 1-12 1.00 TC Vert 0.0 51-10- 4 1.00 BC Vert 40.0 24- 0- 0 0.54 BC Vert 40.0 28- 0- 0 0.00 A71 connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frow Alpine; or preceded by "HX" for TWWX 20 ga. or "H" for 16 ga. frow Trusrral, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 3X8 Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This designIs fm an Individual building w specifications provided by the Component manufacturer B msions not truss tem. It hes been based on 1-�13 ® and done m accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions WO • Dri ve_T_0790809-L000 ' 2.5X6 DS n r' TM 346# 9 #LC = 81 WT: 6X6 3X4 6X8 7X8 3X4 _ O_ 3-13 Li veDu r L=1.25 P=1.25 1 3 W B3 SnOWDU r L=1.15 P=1.1$ W:308 R:1325 32-1-12 W:308 W:308 Rep Mb r Bnd / Comp / Tens #7W Building Components Group, Inc. R:2568 R:574 1.00 / 1.00 / 1.00 U-214 40#1 40#1 U:-243 U:-156 3-0-0 H (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WfCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive. Madison, 49-0-0 Bldg Code' CBC STUB 11 12 13 14 15 16 17 18 A71 connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frow Alpine; or preceded by "HX" for TWWX 20 ga. or "H" for 16 ga. frow Trusrral, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Trufs Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This designIs fm an Individual building w specifications provided by the Component manufacturer B msions not truss tem. It hes been based on DIR : D ri Ve_T-0790809_L00005_700001 ® and done m accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions WO • Dri ve_T_0790809-L000 ' ere to be verified b the co y component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads DS n r' TM 346# 9 #LC = 81 WT: T R U SWA L uti iced on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, TC Live 20.00 psf Li veDu r L=1.25 P=1.25 ® SYSTEMS unless otherwise noted. Bracing shown is far lateral support of oompenenis members only to reduce budding length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19% TC Snow(Pf) 0.00 psf TC Dead 9.00 SnOWDU r L=1.15 P=1.1$ and/or cause connector plate corrosion. Fabricate, handle. install psf Rep Mb r Bnd / Comp / Tens #7W Building Components Group, Inc. and brace this buss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truswal software, 'ANSIfrPI BC Live 0.00 psf 1.00 / 1.00 / 1.00 4445 Nordrpark Dr. Ste. 102, Colo. Spgs., CO 80907 1', -CA V -Wood Truss Council ofAmerica Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION' - BC Dead 8.00 psf O.C.Spaeing 2- 0- 0 TRUSPLUS 6.0 VER: T6.5.9P (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WfCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive. Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street. INK Ste 800. Washington. DC 20036. Bldg Code' CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D ®Web bracing required at each location shown. See ITWBCG's standard details. TC 2x4 DFL #1 1 3- 7- 4 1165 3.50" 1.50" BC 2x4 DFL #1 2 35- 1-12 2525 3.50" 2.32" WEB 2x4 DFL STANDARD 3 51-10- 4 581 3.50" 1.50" GBL BLK 2x4 DFL STANDARD BRG REQUIREMENTS shown are based ONLY Refer to )oint QC Detail Sheets for on the truss material at each bearing Cq factors and Rotational Tolerances. MAX DEFLECTION (span) : 8-17 -71.60 IRC/IBC truss plate values are based on L/960 MEM 14-15 (LIVE) LC 24 ASCE7 II Standard Occupancy, Dead Load = 10.2 testingg and approval as required by IBC 1703 L= -0.39" D= -0.29" T= -0.68" Permanent bracing is relyred to and ANSI/TPI and are reported in available EX.WB DEF CRITERIA:L/120 Tributary Area = 110 sgft document ESR -1118. IN MEM 11- 1; T= 0.00" Loaded for 10 PSF non -concurrent BCLL. CRITICAL MEMBER FORCES: TC COMP. OUR. TENS. DUR. CSI Loaded for 200 lb non -concurrent moving BCLL 91-2 LL/TL -1760 1.251/1175 1.fi 0.69 Mark all interior bearin@Q locations. 2-3 -1821 1.25/ 1911.60.49Install height >= 42" and clear width of >= 24". BC Vert 16.00 3- 5- 8 16.00 52- 0- 0 interior supports) before erection. 3-4 4-5 -1386 1.IS157 -1367 1.25/ 219 1.60 1.60 0.48May 0.36 use adequate staples for gable blocks. S-6 -348 1.25/ 97 1.25 0.287-8 BUILDING DESIGNER MUST VERIFY GABLE LOADS 6-7 -375 ATO, IF TRUSS 8-1 1.60 93o 1:250.56 r ISDDESIGNEDVE SUPPORTLTEBLOADSHIS SPECIFIED 8-9 -316 1.25/ 177 1.25 0.43 BASED ON THE O.C. SPACING AND ANY 9-30 -632 1.25/ 137 1.60 0.53 ADDITIONAL LOADS SHOWN. BC 11-12 COMP OUR. / TENS. DUR. CSI [+l gable bracing required @ 61" intervals, if 12-13 -25(1.603/ 59 -181i(1.6033/ 1698 1.60 1.25 0.38 0.68 expposed to wind load applied to face. See ]'TWBCC s Gable Bracing Details. 13-14 14-15 -106 1.60 / 1666 / 677 1.25 1.25 1.00 0.94 15-16 -803 1.25 / 159 1.60 0.85 2.5X6 _ 1 16-17 -180 1.25 / 243 1.25 0.66 3X4 0-3-13 �5 63 17-18 -101 1.60 / 559 1.25 0.83 W:308 W:308 R:2525 R:581 WB COMP. WR. / TENS. ID I! CSI 1-11 -13. 1.25 / 147 1.60 0.13 1-12 -161 1.60 / 1714 3.25 0.70 2-12 -365 1.25 / 113 1.60 0.06 2-13 -178 1.25 / 85 1.25 0.17 3-13 / 267 1.25 0.11 3-14 -559 1.25 / 154 1.60 0.60 4-14 -297 1.25 / 141 1.60 0.26 ^ I"russ IO: 02X Qty: 1 1.25 ®Web bracing required at each location shown. See ITWBCG's standard details. UPLIFT REACTION(S) Support C&C Wind Non -Wind Designed per ANSI/TPI 1-2002 1 -135 lb 5-15 -8981.25 6-15 -2981.25 This design does not account for long term 2 -252 lb 0.42 0.26 time dependent loading (creep). Building 3 -158 lb Designer must account for this. This truss is designed using the / 1756 THIS DESIGN IS THE COMPOSITE RESULT OF CBC -07 / ASCE7-05 Specification MULTIPLE LOAD CASES. Bldg Enclosed - Yes, Importance Factor = 1.00 IF THIS TRUSS IS CARRIED IN A HANGER, THAT Truss Location = Not End Zone 1.60 1.60 HANGER IS BASED ON 1.5" HANGER NAILS FOR Hurricane/Ocean Line = No Exp Category = C 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY Bldg Length = 72.00 ft, Bidg Width 73.00 ft 8-17 -71.60 CARRYING MEMBERS. IF 2.5" GUN NAILS ARE Mean roof height = 14.49 ft, mph = 85 0.18 USED THE HANGERS MUST BE RE-EVALUATED ETHERS).Designed ASCE7 II Standard Occupancy, Dead Load = 10.2 psf (BY as Main Wind Force Resisting System / 148 Permanent bracing is relyred to - Low-rise and Components and Cladding prevent rotation/toppling. Refer to Tributary Area = 110 sgft SCSI and ANSI/TPI 1. Vertical members exposed to wind: 11- 1 PLATING BASED ON GREEN LUMBER VALUES. ----------LOAD CASE #1 DESIGN LOADS ---------------- 20 psf Live Load applied to bottom chord in Dir L.Plf L.Loc R.Plf R.Loc LL/TL accordance with IBC/IRC requirements for TC Vert 58.00 3- 5- 8 58.00 52- 0- 0 0.69 attics with limited storage having a clear TC Vert 74.00 52- 0- 0 74.00 54- 0- 0 0.54 height >= 42" and clear width of >= 24". BC Vert 16.00 3- 5- 8 16.00 52- 0- 0 0.00 .LocL1 Fastener TC Verrt 0.0 51X10 00 BC Vert 40.0 24- 0- 0 0.54 BC Vert 40.0 28- 0- 0 0.00 5-14 -10411.60 / 1144 1.25 0.47 t 22-6-8 r 26-0-0 , �'.1 i • •.. A 5-15 -8981.25 6-15 -2981.25 / 109 / 123 1.60 1.60 0.42 0.26 1 2 3 4 5 6 7 8 9 10 7-15 -771.60 / 1756 1.25 0.71 l 7-16 -21221.25 8-16 -9421.25 / 181 / 119 1.60 1.60 0.88 0.94 4.00 -4.00-20 +� - ' - -• �. r , ; 8-17 -71.60 / 454 1.25 0.18 52 9-17 -3791.25 / 148 1.60 0.10 6X6 # I 1.5X4 1.5X4 6X6 5 X6 1.5X4 8-1 -13 3 .5X4 r r r r 5X6 9- -11 3.5X6 I SHIP 1-5_T10 2.5X6 _ 1 �(g 3X8 3X4 6X8 7X8 Bi 3X4 0-3-13 �5 63 FESSI Q � W:308 312: R:1165 W:308 W:308 R:2525 R:581 U:-135 40#1 40#1 U:-252 aoU:-158 3-5-8 8-6-8 f-0-1 �' �" m STUB 11 12 13 14 15 16 17 18 . Q 927 N x . June 30, 2011 TYPICAL PLATE: 1X3 C i V II L �Q OF CAL�� All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frac Alpine; or preceded by "NX" for TWNX 20 ga. or "Al" for 16 ga. froom Truswal, positioned per Joint Detail Reports. Circled plates and false frare plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10115/2009 268 - Homewood Tru s R Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUst: Mike and Marci Shedd �CrAj DIR: Drive_T_0790809_L00005_]00001 This designIs for an Individual component g cop system. It hes been based o specifications provided by the component manufacturer WO • Dri ve_T_0790809_L000 ® and done m accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions r Dim are to be verified by the component manufacturer and/or Wilding designer prior to fabrication. The building designer must ascertain that the loads Ds n r • TM 9 #LC = 81 WT' 444# T R U S WA L wined on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf $nOWDU r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce budding length. This component shell not be placed in any environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens and brace this buss in accordance with the following standards:'Join1 and Cutting Detail Repons' available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 J7W Building Components Group, Inc. 'ANSI/TPII%WTCA V- Wood Truss Council of America Standard Design Responsibilities,'BUILDINGCOMPONENTSAFETYINFORMATION - BC Dead 8.00 psf- O.C.Spacing 2- 0- 0 4145 Northport, Or. Ste. 102, Colo. Slogs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onohio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington. OC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC! L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 0- 1-12 487 3.50 1.50 BC 2x4 DFL #1 2 10- 1-12 1334 3.50" 1.50" 2x4 DFL STANDARD 16-7 3 32- 1-12 1844 3.50" 1.97" WEB 2x4 DFL STANDARD 4 48-10- 4 658 3.50" 1.50" Refer to Joint QC Detail Sheets for BRG REQUIREMENTS shown are based ONLY Cq factors and Rotational Tolerances. on the truss material at each bearing IRC/IBC truss plate values are based on MAX DEFLECTION (span) : testing and approval as required by IBC 1703 L/352 MEM 11-12 (LIVE) LC 29 and AN and are reported in available L= -0.34" D= -0.17" T= -0.51" document ESR -1118. CRITICAL MEMBER FORCES: Loaded for 10 PSF non -concurrent BCLL. TC COMP. DUR. / TENS. DUR. CSI 1-2 -310 1.25 / 79 1.60 0.49 Loaded for 200 lb non -concurrent moving BCLL 2-3 -31 1.25 / 216 1.25 0.46 Mark all interior bearingg locations. 3-4 12 1.25 / 266 1.25 o. so Install interior sup ort(s) before erection. 4-5 -708 1.25 / 150 1.60 0.48 PLATING BASED ON GREEN LUMBER VALUES. 5-6 -366 1.25 / 119 1.25 0.54 6-7 13 1.60 / 545 1.25 0.61 20 psf Live Load applied to bottom chord in 7-8 -47 1.60 / saz 1.25 0.49 accordance with IBC/IRC requirements for 8-9 -SO1 1.25 / 79 1.60 0.36 attics with limited storage havinga clear 9-10 -836 1.25 / 156 1.60 0.47 height >- 42" and clear width of >- 24". BC COMP .(DUR.)/ TENS. DUR. CSI 11-12 -30(1.603/ 256 1.25 0.73 12-13 -4(1.60 / 548 1.25 0.57 13-14 / 473 1.25 0.73 14-15 -321 1.25)/ 132 1.60 0.61 15-16 -1802 1.25)/202 1.60 0.18 16-17 / 3 1.25 0.54 17-18 -125(1.60)/ 751 1.25 0.76 WB COMP. DUR. / TENS. WR. CSI 15-7 -319 1.253/ 89 1.25 0.04 2-12 -465 1.25 / 167 1.60 0.13 3-12 -125 1.25 / 46 1.60 0.03 4-12 -1073 1.25 / 138 1.60 0.91 4-13 0 1.25 / 148 1.25 0.06 5-13 / 256 1.25 0.10 5-14 -480 1.25 / 109 1.60 0.19 6-14 -8 1.60 / 824 1.25 0.33 6-15 -1307 1.25 / 166 1.60 0.58 8-1S -949 1.25 / 127 1.60 0.84 Truss ID: D3 -- ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). Shim bearings (if needed) for req. support. 15-17 -6 1.60 / 418 1.25 0.17 23-0-0 26-0-0 8-17 -9 1.60 / 413 1.25 0.17 1 9-17 -396 1.25 / 1S3 1.60 0.11 1 2 3 4 5 6 7 6 9 10 4.00 a.00 Qtv: 2 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -146 lb 2 -134 lb 3 -177 lb 4 -163 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg EnclosedYes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line No Exp Category C Bldg Length - 72.00 ft, Bidg Width 73.00 ft Mean roof height = 13.99 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 98 sqft OVER 4 SUPPORTS N, U, 9-j-1 1 1 SHIP A71 connector plates are Trmwal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. froom Alpine; 6X6 or preceded by "NX" for TWXned 20 ga. or "ve for 16 ga. feat positioned per Joint Detail Reports. Circled plates and false stud fraee plates are positioned as shown above. Shift gable stud plates to avoid overlap with strvetueal plates (or staple). 10/15/2009 268 - Homewood Trup 1.5X4 Cust: Mike and Marci Shadd This design is far an individual ao gn' g m not Was system. It has been based on provided by the DIR: Drive-T_0790809_L00005_100001 5X6 tions and done m accordancewith the anent versions of TPI entl AFPA design standards. No responsibility is assumed for dimensional eaumry. Dimensions responsibility dimensional accuracy. 5X8 are to be vedfied by the component monulacturer endlor buildingdesi ner 9 prior to fabrication. The building designer moat eacertem that the loads DS n r : TM 9 #LC = 79 WT: 322# 1.5X4 -13 calked on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 1.5X4 8-1 -137"1 1.5X4 noted. Bracing shown Is for lateral support of components members only to reduce buckling length. This component shall not be placed In any 3.5X4 Sf10WDU r L=1.15 P=1.15 ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, Install 2.5X6 Rep Mb r Bnd / Comp / Tens IM Building Components Group, Inc. and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Trusval software, 'ANSI/TPI BC Live 0.00 psf 1.15 / 1.10 / 1.10 4445 Northpark Dr. Ste. 102, Colo. Spgs., Co = BC Dead 8.00 psf O. C. Spaei ng 2- 0- 0 80907 2.5X6 13 5X6 3X4 Bldg = 1 B1 4X8 B2 1-0-0 5X12 4X8 tl D-3-13 W:308 W:308 3)(M B4 R:487 10-1-12R:1334 32-1-12 W:308 W:308 U:-146 U:-134 R:1844 R:658 1 32-0-0 1 U-177 I U:-163 17-0-0 49-0-0 11 12 13 14 156 17 18 1 OVER 4 SUPPORTS N, U, 9-j-1 1 1 SHIP A71 connector plates are Trmwal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. froom Alpine; or preceded by "NX" for TWXned 20 ga. or "ve for 16 ga. feat positioned per Joint Detail Reports. Circled plates and false stud fraee plates are positioned as shown above. Shift gable stud plates to avoid overlap with strvetueal plates (or staple). 10/15/2009 268 - Homewood Trup R Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This design is far an individual ao gn' g m not Was system. It has been based on provided by the DIR: Drive-T_0790809_L00005_100001 ® tions and done m accordancewith the anent versions of TPI entl AFPA design standards. No responsibility is assumed for dimensional eaumry. Dimensions responsibility dimensional accuracy. WO: Drive -T -0790809-L000 are to be vedfied by the component monulacturer endlor buildingdesi ner 9 prior to fabrication. The building designer moat eacertem that the loads DS n r : TM 9 #LC = 79 WT: 322# TRU S WA L calked on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 Li L=1.25 P=1.25 Is laterally braced by the factor floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise psf veDu r noted. Bracing shown Is for lateral support of components members only to reduce buckling length. This component shall not be placed In any TC Snow(Pf) 0.00 psf Sf10WDU r L=1.15 P=1.15 ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, Install TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens IM Building Components Group, Inc. and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Trusval software, 'ANSI/TPI BC Live 0.00 psf 1.15 / 1.10 / 1.10 4445 Northpark Dr. Ste. 102, Colo. Spgs., Co 1', WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf O. C. Spaei ng 2- 0- 0 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 O'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO' L/240 TC: L/240 VA Job Name: Shadd / New Residence BRG 1 2 3 4 BRG on BC 10-11 11-12 12-13 13-14 14-15 15-16 16-17 WB -7 2-11 3-11 4-11 4-12 5-12 5-13 6-13 6-14 8-14 14-16 8-16 9-16 9-17 %-L 0- 1- 10- 1- 32- 1- 42- 8- COMP. DUR. / 55 1.60 / 73 1.60 / -39 1.60 / 33 1.25 / -1462 1.25 / -1 1.25 / -33 1.60 / COMP. WR. / 109 1.60 / -464 1.25 / -125 1.25 / -1163 1.25 / -321131 .255.60 /-133 -49 -21.60 / 2011.2.60) -294(5)/ 4CT SIZE REQ'0 488 3.50" 1.50" 398 3.50" 1.SO" 476 3.50" 1.57" 342 3.50" 1.50" shown are based ONLY rial at each bearing pan) : LIVE) LC 32 17" T- -0.51" 4:L/120 0.00" TENS. DUR. CSI 79 1.60 0.49 205 1.25 0.46 255 1.25 o.So 165 1.60 0.48 156 1.60 0.53 304 1.25 0.56 228 1.25 0.48 77 1.60 0.47 TENS. DUR. CSI 261 1.25 0.74 621 1.25 0.58 591 1.25 0.73 123 1.25 0.61 187 1.60 0.15 1 1.60 0.42 58 1.60 0.56 TENS. WR. CSI 195 1.25 0.08 167 1.60 0.13 46 1.60 0.03 163 1.60 0.99 164 1.25 0.07 239 1.25 0.10 1061.60 0.13 666 1.25 0.27 204 1.60 0.59 132 1.60 0.21 196 1.25 0.08 226 1.25 0.09 198 1.25 0.08 91 1.60 0.10 TC 2x4 DFL 41 BC 2x4 DFL #1 2x4 DFL STANDARD 15-7 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearin@@ locations. Install interior supports) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20psf Live Load applied to bottom chord in accordance with IBC/IRC requirements for attics with limited storage having a clear height >= 42" and clear width of >= 24". Truss ID: D4 ®Web bracing requiredat each location shown See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF RIED IN A HANGER, THAT 1.5" HANGER NAILS FOR NAILS FOR MULTI -PLY Shim bearings (if needed) for req. support. End verticals are designed for axial loads only unless noted otherwise. Extensions above or below the truss profile (if any) have been designed for loads indicated only. Horizontal loads applied at the end of the extensions have not been considered unless shown. A drop -leg to an otherwiseunsupported wall ing,create a hinge effect that requires additional design consideration (by others). 23-0-0 i 19-10-8 1 2 3 4 5 6 7 8 9 4.00 -4.00 atv: 3 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -149 lb 2 -144 lb 3 -180 lb 4 -62 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location Not End Zone Hurricane/Ocean Line No Exp Category C Bldg Length = 72.00 ft Bidg Width = 73.00 ft Mean roof height - 13.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 86 sgft Vertical members exposed to wind: 17- 9 OVER 4 SUPPORTS All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "s" for SS 16 ga. frost Alpine; or preceded by "MMC" for 7WM 20 ga. or "H" for 26 ga. frost Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru s 6X6 CUSt: Mike and Marci Shadd CCA. DIR : Dri ve_T_0790809_00005_J 00001 L0000 1.5X4 W0: Drive -T -0790809-L000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads DSgn r: TM #LC = 83 WT: 297# T R U S WA L 5X6 5X8 Li veDu r L=1.25 P=1.25 is laterally braced by the roof a floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf -13 1.5X4 noted. Brading shown is for lateral support of components members only to reduce buckling length. This component shell not be placed in any 3X4 Rep Mbr Bnd / Comp / Tens ®SYSTEMS 8-1 -11-1 1.15 / 1.10 / 1.10 1.5X3 •ANSIfrPI 1', WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 8-1 -13 (SCSI "3) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 191h Street, NW, Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L1240 3X4 SHIP 2.5X6 T = 2t5 3313 3X10 5X6 2.5X4 1- -D 81 B2 1-0-0 7X8 3X8 2X3 W:308 W:308 2.564 B4 R:488 10-1-12 R:1398 32-1-12 W:308 W:308 U:-149 U:-14432-0-0 R:1476 R:342 U:-62 1 42-10-8 3-1-8 10 11 12 13 145 16 17 STUB OVER 4 SUPPORTS All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "s" for SS 16 ga. frost Alpine; or preceded by "MMC" for 7WM 20 ga. or "H" for 26 ga. frost Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru s Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUSt: Mike and Marci Shadd CCA. DIR : Dri ve_T_0790809_00005_J 00001 L0000 This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer W0: Drive -T -0790809-L000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads DSgn r: TM #LC = 83 WT: 297# T R U S WA L Wilted on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof a floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1. 1$ P=1.1$ noted. Brading shown is for lateral support of components members only to reduce buckling length. This component shell not be placed in any TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens ®SYSTEMS environment that will cause the moisture content ofthe "ad to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truawat software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 I>rD9P Building Components Group, Inc. •ANSIfrPI 1', WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI "3) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 191h Street, NW, Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L1240 • f' Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D TC 2x4 DFL #1 1 0- 1-12 424 3.50" 1.50" BC 2x4 DFL #1 2 10- 1-12 2087 3.50" 1.85" WEB 2x4 DFL STANDARD 3 42- 8-12 1282 3.50" 1.50" Refer to )oint QC Detail Sheets for BRG REQUIREMENTS shown are based ONLY Cq factors and Rotational Tolerances. on the truss material at each bearing THIS DESIGN IS THE COMPOSITE RESULT OF MAX DEFLECTION (span) : MULTIPLE LOAD CASES. L/930 MEM 11-12 (LIVE) LC 24 IF THIS TRUSS IS CARRIED IN A HANGER, THAT L- -0.42" D= -0.23" T= -0.65" HANGER IS BASED ON 1.5" HANGER NAILS FOR EX.WB DEF CRITERIA:L/120 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY IN MEM 14- 8; T= 0.00" CARRYING MEMBERS. IF 2.5" GUN NAILS ARE CRITICAL MEMBER FORCES: USED, THE HANGERS MUST BE RE-EVALUATED TC COMP.IOUR. / TENS. DUR. CSI1-2 -1231.zs/423 1.xo.sl (BY OTHERS). 2-3 -1061.60 / 693 1.25 0.54 PLATING BASED ON GREEN LUMBER VALUES. 3-4 -841.60 / 744 1.25 0.60 20 psf Live Load applied to bottom chord in 4-5 -12601.25 / 203 1.600.54accordance with IBC/IRC requirements for 5-6 -18921.25264 1.60 0.586-7 -22531.25 / 321 1.60 a.47 attics with limited storage having a clear 7-8 -22751.25 / 260 1.60 0.85 height >= 42" and clear width of >= 24". BC COMP. DUR. / TENS. DUR, CSI 9-10 -375 1.25 / 79 1.25 0.71 10-11 -74 1.60 / 816 1.25 0.61 11-12 -94 1.60 / 1266 1.25 0.79 12-13 -176 1.60 / 1961 1.25 0.82 13-14 -25 1.60 / 52 1.60 0.60 WB COMP. WR. / TENS. DUR. CSI 2-10 -473 1.25 / 168 1.60 0.13 3-10 -121 1.25 / 46 1.60 0.03 4-10 -2115 1.25 / 26111.60 0.89 4-11 / 589 1.25 0.24 5-11 -295 1.25 / 87 1.60 0.12 5-12 -52 1.60 / 834 1.25 0.34 6-12 -476 1.25 / 1S4 1.60 0.29 6-13 -104 1.60 / 336 1.25 0.14 7-13 -362 1.25 / 176 1.60 0.08 8-13 -217 1.60 / 2133 1.25 0.87 8-14 -1216 1.25 / 191 1.60 0.14 Truss ID: D5 ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interiorbearingg locations. Install interior supports) before erection. 23-0-0 I 19-10-8 1 2 3 4 5 6 7 8 4.00 -4.00 _ Qtv: 5 UPLIFT REACTION(S) : Support C&C3Wind Non -Wind lb 2 -215 lb 3 -162 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bldg Width = 73.00 ft Mean roof height = 13.99 ft, mph = 8S ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 86 sqft Vertical members exposed to wind: 14- 8 6X6 5X6 7-1 -13 1.5X4 1.5X4 1.5X3 8-J1 1 3X8I SHIP = 2.5X6 1-4-5 1 0-3-13 6X8 5X8 5X8 7X8 In 2X3 B1 B2 B3 W:308 101-12 W:308 W:308 R:424 R:2087 R:1282 U:-130 U:-215 U:-162 42-10-8 l 3-1-8 9 10 11 12 13 14 STUB '%ION All- I A _. J All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for US 20 ga., "S" for SS 18 ga. fro Alpine; or preceded by "WX" for 1WNX 20 ga. or "N" for 16 ga, fro Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru ys Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUSt: Mike and Marco Shadd This design is for an Individual building component not truss system. It has been based on specifications provided by the component manufacNrer DIR: Drive_T_0790809_L00005_]00001 ®(CA and done In accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions W0: Dr i ve_T_0790809_L000 are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsg n r : TM #LC = 75 WT: 273# T R U S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterely braced by a rigid sheathing material directly attached, unless otherwise TC SnOw(Pf) 0.00 psf SnOwDU r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any environmentmetwillrauseNemoisturecontentofthewoodtoexceed19%and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace this truss in accordance with the following slandards:'Joint and Cutting Detail Repona available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSI/TPI 1', VJ1CA 1'. Wood Truss Council of America Standard Design Responsibilides,'BUILDING COMPONENT SAFETY INFORMATION'. BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4115 Northpark Dr. Ste. 102, Colo. Spit"' CO 80907 (BCSI 1-03) and'SCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate InsBMe (TPI) Is located at 583 D'Onofrio Drive, Madison, TRU SPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street. NW. Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D 1 7- 1-12 2047 3.50" 1.81" 2 42-10- 4 1958 3.50" 1.71" BRC REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/997 MEM 13-14 (LIVE) LC 53 L- -0.43" D- -0.22" T= -0.65" MAX DEFLECTION (cant) : L/516 MEM 10-11 (LIVE) LC 29 L= -0.17" D= -0.06" T= -0.22" TC COMP. DUR. / TENS. OUR*) CSI OL- 1 0 1.60 / 37 1.25 0.22 1-2 -655 1.60 / 1162 1.25 0.76 2-3 -1606 1.25 / 150 1.60 0.62 3-4 -1578 1.25 / 183 1.60 0.61 4-5 -1576 1.25 / 194 1.60 0,51 5-6 -2053 1.25 / 185 1.60 0.51 6-7 -2117 1.25 / 176 1.60 0.42 7-8 -1219 1.25 / 69 1.60 0.27 8-9 -638 1.60 / 1074 1.25 0.39 9 -OR 0 1.60 / 37 1.25 0.18 BC COMP. DUR. / TENS. DUR. CSI 10-11 -1039 1.25 / 645 1.60 0.54 11-12 -994 1.25 / 711 1.60 0.53 12-13 -30 1.60 / 1478 1.25 0.69 13-14 -103 1.60 / 1922 1.25 0.96 14-15 / 204125 01.22 15-16 -2(1.60)/ 4311:25 0.56 16-17 -916 1.25 / 6401.60 0.40 17-18 -965 1.25 / 6341.60 0.42 WS Cg4P.DUR./ TENS. DUR. CSI 14-6 -1621.25/ 58 1.60 0.24 2-11 -18621.25/ 405 1.60 0.26 2-12 -5321.60/ 2207 1.2S 0.90 3-12 -5581.25/ 247 1.60 0.25 3-13 -21711.601/ 205 1.25 0.33 4-13 / 516 1.25 0.21 5-13 -602 1.25 / 146 1.60 0.27 5-14 -33 , 60 / 239 1.25 0.10 7-14 -201 1.60 / 969 1.25 0.39 14-16 -46 1.60 / 1166 1.25 0.47 7-16 -964 1.25 / 253 1.60 0.21 B-16 -403 1.60 / 1882 1.25 0.76 8-17 -1809 1.25 / 352 1.60 0.23 TC 2x4 DFL #1 2x4 DFL #1 & Btr. 7-9 BC 2x4 DFL #1 2x4 DFL STANDARD 15-6 WEB 2x4 DFL STANDARD Refer to )oint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL PLATING BASED ON GREEN LUMBER VALUES. + + + + + + + + + + + + + + + + + + + + + + OVERHANG(S) MAY BE SHORTENED UP TO 4" MAX. Soffit loading = 0.0 psf, U.N.O. + + + + + + + + + + + + + + + + + + + + + + 2.5X6 - - - � -- --- � - Truss ID: D6 --- - -_ -- ®Web bracing required at each location shown See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT Oy= MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER „ THAT HANGER IS BASED ON 1.5" HANGER NAILS'FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). 20 pf bottom chord live load NOT required on this truss per IBC/IRC requirements for attics with limited storage. . 23-0-0 26-0-0 1 2 3 4 5 6 7 8 9 r 4.00 -4.00 3.5X4 6X8 1.5X4 3.5X4 06 (qty: �3 UPLIFT REACI'ION(S) : Support C&C Wind Non -Wind 1 -412 lb 2 -394 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line No Exp Category - C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 13.99 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 98 sqft 2.5X6 1-D-0 2.5:M 6X12 4X8 1 -D-0 SX82.5X4 4X10 2X4 0-3-13 W:308 B2 7-0-0 R:2047 W:308 6-0-0 UA12 R:1958 32-0-0 U:-394 I 17-0-0 49-0-0 10 11 12 13 145 16 17 18 All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. frost Alpine; or preceded by "W" for TWMX 20 ga. or "N" for 16 ga. frost Tmswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 fraste plates are positioned as shown above. Shift gable stud plates to amid overlap with structural plates (or staple). 268 - Homewood Trus Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd (CA DIR: Drive_T_0790809_L00005_100001 This design is for an Individual building component not ss system. It has been based on apedfleetions provided by the component manufacturer ve WO • Dri ve_T_0790809_L000 ® end done In accordance with the anent vemlons of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions ere to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer moat ascertain that the loads Ds n r ' • #LC = 86 WT' 323# 9 T R U S WA L utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf L i veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached. unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Brading shown is for lateral support of components members only to reduce buckling length. This component shall not be placed In any environment thal will muse the moisture content of the "ad to exceed 19% and/or muse connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace thistruss in accordance with the (allowing standards: 'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 RM Building Components Group, Inc. 'ANSI?PI 1',';ZA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1.03) and'BCSI SUMMARY SHEETS' by W1CA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association(AFPA)islocated at1111191hStreet. NW. Ste 800.Washington, OC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'DTC 2x4 DFL #1 1 7- 1112 2152 3.50" 1.92" 2x4 DFL #1 & Btr. 7-9 2 45-10- 4 1677 3.50" 1.50" BC 2x4 DFL #1 BRG REQUIREMENTS shown are based ONLY 2x4 DFL #1 & Btr. 12-14 on the truss material at each bearing 2x4 DFL STANDARD 15-6 MAX DEFLECTION (span) : WEB 2x4 DFL STANDARD L/999 MEM 13-14 (LIVE) LC 53 THIS DESIGN IS THE COMPOSITE RESULT OF L= -0.42" D= -0.27" T- -0.68" MULTIPLE LOAD CASES. MAX DEFLECTION (cant) : IF THIS TRUSS IS CARRIED IN A HANGER, THAT L/S11 MEM 10-11 (LIVE) LC 29 HANGER IS BASED ON 1.5" HANGER NAILS FOR L= -0.17" D= -0.05" T= -0.21" 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CRITICAL MEMBER FORCES: CARRYING MEMBERS. IF 2.5" GUN NAILS ARE TC COMP. WR. / TENS. DUR. "Si 0L- 1 0 l.zs / 37 1125 o.22 USED THE HANGERS MUST BE RE-EVALUATED 1-2 -655 1.60 / 1161 1.25 o.76 (BY ETHERS). 2-3 -18181.25 / 2101.60 0.63 ++++++++++++++++++++++ 3-4 -1859 1.25 / 262,f 1.60 0.61 OVERHANG(S) MAY BE SHORTENED UP TO 4" MAX. 4-5 -1858 1.25 / 27z 1.60 o.ss Soffit loading 5-6 -2774 1.25 / 339 1.60 0.53 g - 0.0 psf, U.N.O. 6-7 -28441.25 / 3201.60 0.46 + +++++++++++++++ ++++++ 7-8 -2579 1.25 / 257 1.60 0.38 8-9 -290 1.60 / 526 1.25 0.34 BC COMP. DUR. / TENS. DUR. CSI 10-11 -1038 1.25 / 645 1.60 0.54 11-12 -989 1.25 / 694 1.60 0.52 12-13 -103 1.60 / 1682 1.25 0.59 13-14 -176 1.60 / 2526 1.25 0.85 14-15 / 201 1.25 0.35 15-16 -5(1.60)/ 70 1.25 0.56 16-17 -355((1.25))/ 489 1.60 0.45 17-18 -477 1.25 / 284 1.60 0.41 WB COMP. DUR. / TENS. DURCSI 14-6 -123 1.25 / 43 1.,6 0.39 2-11 -1987 1.25 / 420 1.60 0.28 2-12 -554 1.60 / 2406 1.25 0.98 3-12 -618 1.25 / 254 1.60 0.28 3-13 -122 1.60 / 243 1.25 0.19 4-13 -4 1.60 / 694 1.25 0.28 -truss ID: D7 Qtv: 1 ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testingg and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 5-13 -993 1.25 / 189 1.60 0.41 23-0-0 26-0-0 5-14 -10 1.60 / 504 1.25 0.20 7-14 -45 1125 / 271 1.25 0.11 1 2 3 4 5 6 7 8 9 14-16 -175 1.60 / 2361 1.25 0.96 7-16 -590 1.25 / 145 1.60 0.13 8-16 -242 1.60 / 2214 1.25 0.90 4.00 -4.00 8-17 -1543 1.25 / 258 1.60 0.17 UPLIFT' REACI'ION(S) : Support C&C-42S Wind Non-Wind lb 2 -274 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean LineNo Exp Category = C Bldg Length = 72.00 ft Bldg Width = 73.00 ft Mean roof height = 13.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 98 sqft 6X6 1.5X4 3.5X4 3.5X4 7-1 -13 8-1 -13 6X8 5X6 8-1 -13 2.5X6I SHIP :c.5X6 4X8 1 13 2.5X4 7X16 4X8 5X12 = 1- -� B1 1-0-0 2.5X4 7X8 2X4 0-3-13 W:308 B2 7-0-0 R:2152 W:308 3-0-0 U:425 32-0-0 R:1677 --- 170 10 11 12 13 145 16 1718 M All connector plates are lrusaal 20 Be. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frog Alpine; _11--m-aa-0- 11--m-aa-0or preceded by "WX" for TWMK 20 Be. or "H" for 16 ga. from Trusrtal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 or fraae plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood �Tr�up Read all notes on this sheet and give a copy of it to the Erecting Contractor. Mike and Marco Shedd This design Is for an Individual building ro provided by the component manufacturer 9 9 rasions not truss system. It hes been based on DIR:Cust: DIR: Dri ve_T_0790809_L00005_J00001 WO • Drive -T -0790809-L000 ' ® spolGaaBorre end done th accordance with the anent versions of TPI end AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC 86 WT: 324# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads = utilized on this design meet or exceed mmm e loading imposed by the local building code end the particular application. The design assues at the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19% end/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf p Re p Mbr Bnd / Comp / Tens and brace this truss in accordance with the following standards: 'Joint and Cueing Detail Reports' available as output from TmswM sonware, BC Live 0.00 psf 1.15 / 1.10 / 1.10 NFW Building Components Group, Inc. 'ANSI/TPI1%WTCAV. Wood Truss Council of America Standard Design Responsibilities,EUILDINGCOMPONENTSAFETYINFORMATION - BC Dead 8.00 psf O.C.Spacing 2- 0- 0 445 Normparlt Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'SCSI SUMMARY SHEETS' by WTCA and TPI. The Tmas Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I I 9th Street. NW, Ste 600, Washington, OC 20036. Bldg Code' CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence -truss ID: D78; Qty: 1 ERG X -LOC REACT SIZE REQ'D 1 7- 1-12 2150 3.50" 1.92" 245-10- 4 1594 3.50" 1.70" BRC REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 12-13 (LIVE) LC 53 L- -0.42" D= -0.27" T= -0.69" MAX DEFLECTION (cant) : L/511 MEM 9-10 (LIVE) LC 29 L= -0.17" D- -0.05" T= -0.21" EX.WB DEF CRITERIA:L/120 IN MEM 16- 8; T= 0.00" TC COMP. DUR. / TENS. OUR. CSI OL- 1 0 1.25 / 37 1.25 0.22 1-2 -655 1.60 / 1161 1.25 0.77 2-3 -1826 1.25 / 11611:60 0.63 3-4 -1869 1.25 / 269 160 0.61 4-5 -1867 1.25 / 280 1.60 0.55 5-6 -2788 1.25 / 353 1.60 0.53 6-7 -2867 1.25 / 339 1.60 0.58 7-8 -2636 1.25 / 279 1.60 0.73 BC COMP.(DUR. / TENS. DUR. c5I 9-10 -1038(1.25 / 645 1.60 0.53 10-11 -988 1.25 / 703 1.60 0.52 11-12 -139 1.60 / 1689 1.25 0.59 12-13 -232 1.60 / 2547 1.25 0.85 13-14 / 199 1.25 0.35 14-15 -7 1.60 / 71 1.25 0.55 15-16 -56 1.60 / 51 1.60 0.59 W8 COMP. DUR. / TENS. DURCSI 13-6 -89 1.25 / 26 1.66 0.40 2-10 -1992 1.25 / 421 1.60 0.28 2-11 -555 1.60 / 2413 1.25 0.98 3-11 -620 1.25 / 254 1.60 0.28 3-12 -117 1.60 / 246 1.25 0.18 4-12 -9 1.60 / 700 1.25 0.28 5-12 -1006 1.25 / 192 1.60 0.41 5-13 -11 1.60 / 496 1.25 0.20 7-13 -80 1.25 / 198 1.25 0.08 13-15 -244 1.61 / 2424 1.25 0.98 -6 7-15 01 1.25 / 153 1.60 13 8-15 -233 1.60 / 2479 1.25 0.0.37 8-16 -1512 1.25 / 288 1.60 0.17 TC 2x4 DFL #1 2x4 DFL #1 & Btr. 7-8 BC 2x4 DFL #1 2x4 DFL #1 & Btr. 11-13 2x4 DFL STANDARD 14-6 WEB 2x4 DFL STANDARD 2x4 DFL #1 15-8 THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.S" HANGER NAIL FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Left Overhangs) are not to be removed. OVERHANG(S) MAY BE SHORTENED UP TO 3" MAX.! Left Overhang Soffit loading = 0.0 psf Web bracing required at each location shown. ®See ITWBCG's standard details. aa[PM]=PLATE MONITOR USED -See Joint Report - Designed per ANSI/TPI 1-2002 This design does not accountfor long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testingy and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. . Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss/ per IBC/IRC requirements for attics with 1Tmited storage. r 23-0-0 23-0-0 1 2 3 4 5 6 7 8 -4.00 6X6 UPLIFI' REACfION(S) : Support C&C Wind Non -Wind 1 -426 lb 2 -260 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, .No Width = 73.00 ft Mean roof height = 13.99 ft, mph = 8S ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area.. 92 sqft Vertical members exposed to wind: 16- 8 2.5X6 1-0-02.5X4 1-0-0 2.5X4 8X8 2X4 W: W:308 62 7-0-0 R:2150 W:308 U:-426 32-0-0 R:1594 U:-260 14-0-0a 46-0-0 0 9 10 11 12 134 15 16 STUB All connector plates are Truswal 20 ga. unless preceded by "h" for have 20 ga., "HS" for HS 20 ga., "S" for SS 16 ga. fres Alpine; All or preceded by "MX" for TMMX 20 ga. or "N" for 16 ga. fros Trusral, positioned per Joint Detail Reports. circled plates and false 10/15/2009 frase plates are positioned as shorn above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUst: Mike and Marci Shedd p This design Is for an Individual building component not trues system. It hes been based on specifications provided by the component manufacturer DIR: Drive_T_0790809_L0000$_100001 WO • Dri ve_T_0790809_L000 ® and done in accordance with me anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r: TM #LC = 79 WT: 316# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or goof sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support or components members only to reduce buckling length. This component shell not be placed in any TC Dead 9.00 psf Rep Mb r Brill / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install BC Live 0.00 1.1$ 1.10 1.10 and brace this truss in accordance with the following standards:'Jom1 and Cutting Detail Reports' available as output from Truswal software, psf P / / 17WBuilding Components Group, Inc. *ANSIfTPI V, W17CA V- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf O.C.Spacing 2- 0- 0 1145 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet, NW. Ste $00,Washington, DC20036. Bldg Code: CBC -07 DEFL RATIO' L/240 TC' L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D Cust: Mike and Marci Shadd 'rC 2x4 DFL #1 1 7- 1-12 2148 3.50" 1.92" 2x4 DFL #1 & Btr. 7-9 2 45-10- 4 1806 3.50" 1.55" BC 2x4 DFL #1 BRG REQUIREMENTS shown are based ONLY 2x4 DFL #1 & Btr. 12-14 on the truss material at each bearing 2x4 DFL STANDARD 1S-6 MAX DEFLECTION (span) : ® SYSTEMS WEB 2x4 DFL STANDARD L/999 MEM 13-14 (LIVE) LC 53 and Mace this truss in accordance with the following standards: *Joint and Cutting Detail Repons' available as output from Truswat software, 2x4 DFL #1 16-8 L= -0.42" D= -0.26" T= -0.68" BC Dead 8.00 psf THIS DESIGN IS THE COMPOSITE RESULT OF MAX DEFLECTION (cant) : MULTIPLE LOAD CASES. L/511 MEM 10-11 (LIVE) LC 29 DEFL RATIO: L/240 TC: L/240 IF THIS TRUSS IS CARRIED IN A HANGER THAT L= -0.17" D= -0.05" T= -0.22" HANGER IS BASED ON 1.5" HANGER NAILf FOR CR111CAL MEMBER FORCES: 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY TC DL- 1 COMP. OUR. / TENS. 0 1.60 / 37 OUR. 1.25 CSI 0.22 CARRYING MEMBERS. IF 2.5" GUN NAILS ARE 1-2 -655 1.60 / 1161 1.25 0.76 USED, THE HANGERS MUST BE RE-EVALUATED 2-3 -1812 1.25 / 191 1.60 0.63 (BY OTHERS). 3-4 5-6 -18501.25 / 2361.60 -2752 1 % 173 i.60 0.61 0.53 ++ ++++++++++++++ + ++ +++ OVERHANGS) MAY BE SHORTENED UP TO 4" MAX. 6-7 -2822 1.25 / 254 1.60 0.47 Soffit loading = 0.0 psf, U.N.O. 7-8 -25421.25 / 1931.60 0.38 ++++++++++++++++++++++ 8-9 -531 1.60 / 699 1.25 0.40 9 -OR 0 1.25 / 37 1.25 0.18 BC COMP. DUR. / TENS. DUR. CSI 10-11 -1038 1.25 / 645 1.60 0.54 11-12 -989 1.25 / 711 1.60 0.52 12-13 -64 1.60 / 1676 1.25 0.59 13-14 -156 1.60 / 2508 1.25 0.84 14-15 / 201 1.IS 0.34 15-16 -5 1.60 / 69 1.25 0.56 16-17 -510 1.25 / 484 1.60 0.43 17-18 -637 1.25 / 535 1.60 0.40 W8 COMP. DUR. / TENS. DUR. CSI 14-6 -122 1.25 / 46 1.60 0.39 2 -ll -1983 1.25 / 418 1.60 0.28 2-12 -550 1.60 / 2400 1.25 0.98 3-12 -616 1.25 / 253 1.60 0.28 3-13 4-13 -130 1.60 / 241 / 688 1.25 1 25 0.20 0 28 T Fruss ID: D7T ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss,per IBC/IRC requirements for attics with limited storage. S-13 -981(1.25)/ 182 1.600.40 23-0-0 l 26-0-0 5-14 / 492 1.25 0.20 r 7-14 -59 1.60 / 322 1.zS 0.13 1 2 3 4 5 6 7 8 9 14-16 -153 1.60 / 2327 1.25 0.95 7-16 -625 1.25 / 171 1.60 0.13 8-16 -508 1.60 / 2526 1.25 0.38 r4 _00 8-17 -1680 1.25 / 349 1.60 0.19 Qty: 1 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -423 lb 2 -361 lb This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category C Bldg Length = 72.00 ft Bidg Width 73.00 ft Mean roof height = 13.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 98 sgft 2.5X6 v:-vc.5 32-0-0 U:-361 17-0-0 49-0-0 r 10 11 12 13 145 16 1718 1 31 � All connector plates arc Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. frw Alpine; `ter or preceded by "NX" for TI/MX 20 ga. or "H" for 16 ga. frw Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 fraae plates Pre positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Trup WARNINGRead all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This design Is for an Individual building component not truss system. It has been based on specifications provided by the component manufacturer DIR : D rT ve_T_0790809_L00005_100001. W0: Drive -T -0790809-L000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimenslonal accuracy. Dimensions Dsgn r: TM #LC = 86 yr : 328# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L Is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed In any TC Dead 9.00 psf Rep Mbr BrillBrill/ Comp / Tens ® SYSTEMS environment that will cause the moisture content of the "ad to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install BC Live 0.00 1.10 and Mace this truss in accordance with the following standards: *Joint and Cutting Detail Repons' available as output from Truswat software, psf 1.15 / / 1.10 IM Building Components Group, Inc. •ANSI/1PI 1', WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf O. C. Spaei ng 2- 0- 0 4445 Northpark Or. Ste. 102, Coto. Spits., CO 80907 (SCSI 1-03) snd'8CSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin53719. The American Forest and Paper Association (AFPA)islocated at111119IhStreet. NW. Ste 800.Washington. DC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL :1 1 0- 1-12 1469 3.50" 1.57" 2x4 DFL #1 & Btr. 1-2 2 36-10- 4 2914 3.50" 2.73 BC 2x4 DFL #1 3 48-10- 4 160 HGR 1.50" 2x4 DFL #1 & Btr. 10-13 BRG REQUIREMENTS shown are based ONLY WEB 2x4 DFL STANDARD on the truss material at each bearing Refer to Joint QC Detail Sheets for BRG HANGER/CLIP NOTE Cq factors and Rotational Tolerances. (s) are ds. truss plate values are based on loads. testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available NOTES document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL 80" Mark all interior bearing locations. Permanent bracing is required to prevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. CSI 1.85 1.60 46 39 37 .48 72 56 BC COMP.(DUR. / TENS. DUR. CII 10 -ll -234(1.603/ 3073 1.25 0.71 11-12 -236((1.603/ 30661.25 0.67 32-13 -137 1.60 / 218411 .25 0.94 13-14 / 8511.25 0.95 14-15 -1371(1.25)/ 1861.60 0.83 15-16 -676((1.253/ 791.60 0.54 16-17 27 1.60 / 581.60 0.41 Wit COMP.(WR.)/ TENS. DUR. CSI 2 -ll / 326 1.25 0.13 2-12 -926 1.25 / 175 1.60 0.93 3-12 -20 1.60 / 428 1.25 0.17 3-13 -840 1.25 / 130 1.60 0.87 4-13 -283 1.25 / 139 1.60 0.24 5-13 -119 1.60 / 1393 1.25 0.57 5-14 -969 1.25 / 1]9 1.60 0.45 6-14 -359 1.25 / 142 1.60 0.31 7-14 -110 1.60 / 2309 1.25 0.94 7-15 -2507 1.25 / 221 1.60 0.98 8-15 -966 1.25 / 159 1.60 0.97 8-16 / 320 1.25 0.13 9-16 -683(1.25)/ 66 1.60 0.29 9-17 -131(1.25)/ 334 1.25 0.14 Truss ID: D8 ®Web bracing required at each location shown. See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). Install interior support(s) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20 psf Live Load applied to bottom chord in accordance with IBC/IRC requirements for attics with limited storage having a clear height >= 42" and clear width of >= 24". Qtv: 5 Required bearing widths and bearing areas apply when truss not supported in a hanger. UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -228 lb 2 -292 lb 3 -S7 lb -306 lb This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category - C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height - 14.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 111 sqft Vertical members exposed to wind: 17- 9 ----------LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 49- 0- 0 0.69 BC Vert 16.00 0- 0- 0 16.00 49- 0- 0 0.00 Type... lbs X.Loc LL/TL Fastener TC Vert 0.0 0- 1-12 1.00 BC Vert 40.0 24- 0- 0 0.54 8C Vert 40.0 28- 0- 0 0.00 1 26-0-0 r 23-0-0 r r 1 2 3 4 5 6 7 8 9 T R U S WA L 4.D TC Live 20.00 psf --4.00 is laterally braced by the reef or goon sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow Pf 0. OO psf 6X6 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any environmentthalwillcauaethemoisturecontentolthewood1.exceedI.%endforcauseconnectorplatecorrosion. Fabricate,handle,install TC Dead 9.00 psf 1.5X4 1.5X4 BC Live 0.00 psf 1.00 / 1.00 / 1.00 3.5X4 'ANSIrrPI 1•, WTCA 1•- Wood Truss Council of America Standard Design Responsibilifles,'BUILDING COMPONENT SAFETY INFORMATION'- 6X6 O. C. Spaei ng 2- 0- 0 8-1 -13 5X8 25X6 9- -11 Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I I 9th Street, NW, Ste 800, Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 3.5X4T 3X10 tSHIP u 1-xLi3 0-3-13 1.5X4 3X4 7X8 6X10 3.5X4 B1 A121 2X3 B3 W:308 4 R:1469 36 10 4 O8 R:2914 LLUS26 W:308 U:-228 40#1 40#1 U:-292 R:160 U:-306 T=j 49-0-0 , 3-0-0 10 11 12 13 14 15 16 17 STUB All connector plates are Truswal 20 ga. unless preceded by "M' for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. fret Alpine; or preceded by "HX" for Ti 20 ga. or "H" for 16 ga. froom Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frawe plates aro positioned as drown above. Shift gable stud plates to amid overlap with structural plates (or staple). 268 - Homewood Trr�uss Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This designIs for an Individual co g component not was system. It hes been based on specifications provided by the component manufacturer DIR: Drive_T_0790809_L00005_100001 ve Ve WO' Dri_T_0790809_L000 ® end done m accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions ere to be verified by the component manufacturer andfor building designer prior to fabrication. The building designer moat ascertain that the loads DS n r • #LC = 81 WT • 33 5# 9 T R U S WA L utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the reef or goon sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow Pf 0. OO psf Sr10WDU r L=1.15 P=1. 1$ ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any environmentthalwillcauaethemoisturecontentolthewood1.exceedI.%endforcauseconnectorplatecorrosion. Fabricate,handle,install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 RM Building Components Group, Inc. 'ANSIrrPI 1•, WTCA 1•- Wood Truss Council of America Standard Design Responsibilifles,'BUILDING COMPONENT SAFETY INFORMATION'- BC Dead 8.00 psf O. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institue (TPI) is located at 583 D'Onofrio Drive, Madison. TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I I 9th Street, NW, Ste 800, Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence Truss ID: D8A Qtv: 3 BRG X -LOC REACT SIZE REQ'0 1 0- 1-12 1469 3.50" 1.57" 2 36-10- 4 2914 3.50" 2.73" 3 48-10- 4 160 3.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/958 MEM 13-14 (LIVE) LC 24 L= -0.46" D= -0.34" T- -0.80" EX.WB DEF CRITERIA:L/120 IN MEM 17- 9; T= 0.00" CRITICAL MEMBER FORCES: TC COMP. DUR. / TENS. DUR. C5I 1-2 -3299 1.25 / 277 1.60 0.85 2-3 -2394 1.25 / 227 1.60 0.60 3-4 -1699 1.25 / 180 1.60 0.46 4-5 -1681 1.25 / 235 1.60 0.39 5-6 -436 1.IS / 151 1.60 0.37 6-7 -437 1.25 / 89 1.60 0.48 7-8 -115 1.60 / 1553 1.25 0.72 8-9 -80 1.25 / 721 1.25 0.56 BC COMP. DUR. / TENS. DUR. CSI 10-11 -234 1.60 / 3073 1.25 0.71 11-12 -236 1.60 / 3066 1.25 0.67 12-13 -137 1.60 / 2184 1.25 0.94 13-14 / 851 1.25 0.95 14-15 -1371(1.25)/ 186 1.60 0.83 15-16 -676 1.25 / 79 1.60 0.54 16-17 27 1.60 / 58 1.60 0.41 WB COMP.(DUR.)/ TENS. WR. CSI 2-11 / 326 1.25 0.13 2-12 -926 1.25 / 175 1.60 0.93 3-12 -20 1.60 / 428 1.25 0.17 3-13 -840 1.25 / 130 1.60 0.87 4-13 -283 1.25 / 139 1.60 0.24 5-13 -ll9 1.60 / 1393 1.25 0.57 5-14 -969 1.25 / 119 1.60 0.45 6-14 -359 1.25 / 142 1.60 0.31 7-14 -ll0 1.60 / 2309 1.25 0.94 1-15 -2507 1.25 / 221 1.60 0.98 8-15 -966 1.25 / 159 1.60 0.97 8-16 / 320 1.25 0.13 9-16 -683(1.25)/ 66 1.60 0.29 9-17 -131(1.25)/ 334 1.25 0.14 TC 2x4 DFL #1 2x4 DFL #1 & Btr. 1-2 BC 2x4 DFL #1 2x4 DFL #1 & Btr. 10-13 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testinand approval as required by IBC 1703 and AN?I/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Permanent bracing is required to grevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. Web bracing required at each location shown. ®See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). Install interior support(s) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20psf Live Load applied to bottom chord in accordance with IBC/IRC requirements for attics with limited storage having a clear height >= 42" and clear width of >= 24". 26-0-0 r 23-0-0 1 2 3 4 5 6 7 8 9 4.00 -4.00 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -228 lb 2 -292 lb 3 -57 lb -306 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 14.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 111 sgft Vertical members exposed to wind: 17- 9 ----------LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 49- 0- 0 0.69 BC Vert 16.00 0- 0- 0 16.00 49- 0- 0 0.00 .Type... lbs X.Loc LL/TL Fastener TC Vert 0.0 0- 1-12 1.00 BC Vert 40.0 24- 0- 0 0.54 BC Vert 40.0 28- 0- 0 0.00 6X6 1.5X4 1.5X4 T 3.5X4 6X6 8-1 -13 5X8 5X6 9-7-11 3.5X4 I SHIP x 3X10 1-3-13 1 0-3-13 1.5X4 3X4 7X8 6X10 3.5X4 B1 3.U6 2X3 B3 W:308 36-104 W:308 W:308 R:1469 R:2914 R:160 U:-228 40#1 40#1 U:-292 U:-306 49-0-0 .3-0-0 10 11 12 13 14 15 16 17 STUB f'i1 J All connector plates are Truswal 20 Be. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 16 Be. frow Alpine; or preceded by "NX" for TWWX 20 ga. or "N" for 16 ga. from Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 framere plates apositioned as shove. own abShift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru s Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUst: Mike and Marci Shadd (C , This design Is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer DIR: Drive_T_0790809_L00005_100001 WO ' � Dri ve_T_0790809_L000 ® and done in accordance with the current versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC = 81 WT: 335# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading Imposed by the low[ building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord Is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any environment that wifl cease the moisture content of the wood to exceed 19% and/or muse connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens and brace this buss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 IM Building Components Group, Inc. 'ANSI/TPl1%VVTCA V- Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf O.C.Spacing 2- 0- 0 4445 Northpark D, Ste. 102, Colo. Spgs., CO 60907 (BCSI 1.03) and'BCSI SUMMARY SHEETS' by WfCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street. NW, Ste 800, Washington, DO 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence CRITICAL MEMBER FORCES: TC 2x4 DFL #1 BC 2x4 DFL #1 GBL BLK 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL May use adequate staples for gable blocks. BUILDING DESIGNER MUST VERIFY CABLE LOADS AND EAVE LOADS, IF APPLICABLE. THIS TRUSS IS DESIGNED TO SUPPORT THE LOADS SPECIFIED BASED ON THE O.C. SPACING AND ANY ADDITIONAL LOADS SHOWN. [+3 gable bracing required @ 61" intervals, if exposed to wind load applied to face. See ITWBCG's Gable Bracing Details. Truss ID: D8G Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF TRUSS IS CARRIED IN A HANGER THAT IS BASED ON 1.5" HANGER NAIL FOR NO 3" HANGER NAILS FOR MULTI -PLY G MEMBERS. IF 2.5" GUN NAILS ARE HE HANGERS MUST BE RE-EVALUATED ERS). BASED ON GREEN LUMBER VALUES. Live Load applied to bottom chord in nce with IBC/IRC requirements for with limited storage having a clear >= 42" and clear width of >= 24". —vOvIyI�I V4 -O O ao�hi-1-h O O O O O O � O OO OOO'1,1, 4,NOOv04 26-0-0 3-0-0 1 2 3 4 5 6 7 8 9 10111213141516171 20212223242526272829303132333438 1 8-113 _ 2.5X 0-3-13 4.00 -4.00 3.5X4 1 This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line No,Exp Category = C Bldg Length = 72.00 ft, Bdg Width 73.00 ft Mean roof height = 14.49 ft, mph 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area - 98 sgft J=J.0Atj J=:i.bAb OVER CONTINUOUS SUPPORT 38 39404142434445464748495051593545556 57585966626364 4-0-0 �J>'1�1�1>rJ>'1>rJ�J�J�1>'Jr1lrll`1�1�11�1�� TYPICAL PLATE: 1.5X4 OVER l All connector plates are Trusrrai 20 Be. unless preceded by "W" for Wave 20 ga., "16" for HS 20 ga., "S" for SS 18 Be. frow Alpine; or preceded by "WX" for TWXX 20 Be. or "H" for 16 Be. from Trustral, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frme plates are positioned as shown above. Shift gable stud plates to amid overlap with structural plates (or staple). 268 - Homewood Truss Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This design Is for an individual building component not trues tem. It has been based on ecificotions provided b the co 9 9 mp sys p p y nsionalaccuracy. DIR: Dri ve_T_0790809_L00005_300001 W0: Drive ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional ecwrery. Dimensions im -7_0790809—L000 DS n r • TM #LC ]2 WT' 4]4# are to be verified by the component manufacturer andlor building designer prior to fabrication. The building designer must ascertain that the loads 9 = R S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 T U is laterelty braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf Sf10WDU r L=1.15 P=1.1$ noted, gracing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed is%end/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards:' Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSI/TPI 1', VJICA V. Wood Truss Council of America Standard Design Responsibilities, 13UILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 IIIc Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WICA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated atIII119thStreet. NW, Ste 800,Washington, OC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'0 1 3- 7- 4 1268 3.50" 1.50" 2 36-10- 4 2434 3.50" 2.22" 3 48-10- 4 267 3.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/954 MEM 13-14 (LIVE) LC 24 L. -0.42" D= -0.31" T= -0.72" EX.WB DEF CRITERIA:L/120 IN MEM 17- 9' T= 0.00" CRITICAL MEMBER FORCES: TC COMP. DUR. / TENS. WR. CSI 1-2 -1940 1.25 / 192 1.60 0.43 2-3 -2055 1.25 / 212 1.60 0.50 3-4 -1655 1.25 / 18111.60 0.50 4-5 -1637 1.25 / 2331.60 0.33 5-6 -715 1.2S / 1661.60 0.36 6-7 -718 1.25 / 1051.60 0.48 7-8 -72 1.60 / 8991.25 0.61 8-9 -283 1.25 / 2671.25 0.49 BC COMP.j11)u6R.j/ TENS. DUR. CSI 10-11 -50.059 1.600.34 11-12 -1981.60/ 1876 1.250.6012-13 -1251.60/ 1885 1.25 0.89 13-14-61.60/ 941 1.25 0.96 14-15 -7581.25/ 154 1.60 0.79 15-16 -2431.25/ 237 1.25 0.55 16-17 -601.60/ 54 1.60 0.41 W8 COMP. DUR. / TENS. DUR. CSI 1-10 -1244 1.25 / 155 1.60 0.14 1-11 -177 1.60 / 1893 1.25 0.77 2-11 -409 1.25 / 120 1.60 0.06 2-12 -164 1.25 / 102 1.25 0.16 3-12 / 261 1.25 0.11 3-13 -531 1.25 / 152 1.60 0.55 4-13 -285 1.25 / 137 1.60 0.25 5-13 -102 1.60 / 1130 1.25 0.46 5-14 -622 1.25 / 95 1.60 0.29 6-14 -351 1.25 / 142 1.60 0.30 7-14 -88 1.60 / 1846 1.25 0.75 7-15 -2084 1.25 / 201 1.60 0.94 8-15 -810 1.25 / 157 1.600.82 8-16 / 274 1.25 0.11 9-16 -242(1.25)/ 245 1.25 0.10 9-17 -238 1.25 / 95 1.25 0.04 TC 2x4 DFL #1 BC 2x4 DFL #1 2x4 DFL #1 & Btr. 10-13 WEB 2x4 DFL STANDARD GBL BLK 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Permanent bracing is required to prevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. PLATING BASED ON GREEN LUMBER VALUES. 20 psf Live Load applied to bottom chord in accordance with IBC/IRC requirements for attics with limited storage having a clear height >= 42" and clear width of >= 24". Truss ID: D8X ®Web bracing required at each location shown See ITWBCG's standard details. Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). Install interior support(s) before erection May use adequate staples for gable blocks. BUILDING DESIGNER MUST VERIFY GABLE LOADS AND EAVE LOADS, IF APPLICABLE. THIS TRUSS IS DESIGNED TO SUPPORT THE LOADS SPECIFIED BASED ON THE O.C. SPACING AND ANY ADDITIONAL LOADS SHOWN. [+] gable bracing required @ 61" intervals, if exposed to wind load applied to face. See ITWBCG's Gable Bracing Details. 1 22-6-8 1 23-0-0 1 1 2 3 4 5 6 7 8 9 4.00 -4.00 Qtv: UPLIFT REACIION(S) : Support C&C Wind Non -Wind 1 -144 lb 2 -247 lb 3 -53 lb -67 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category - C Bldg Length = 72.00 ft, Bldg Width = 73.00 ft Mean roof height = 14.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 103 sgft Vertical members exposed to wind: 10- 1, 17- 9 --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 58.00 3- 5- 8 58.00 49- 0- 0 0.69 BC Vert 16.00 3- 5- 8 16.00 49- 0- 0 0.00 Type... lbs X.Loc LL/TL Fastener BC Vert 40.0 24- 0- 0 0.54 BC Vert 40.0 28- 0- 0 0.00 TYPICAL PLATE: 1X3 All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frow Alpine; or preceded by "WX" for TNHX 20 ga. or "H" for 16 ga. frow Truswal, positioned per Joint Detail Reports. Circled plates and false fraae plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Try s WARNING Read a0 notes on this sheet and give a copy of it to the Erecting Contractor. 6X6 This design N for an Individual building component not truss system. It has been based on specifications provided by the component manufacturer DIR: DIR: Drive_T_0790809_L00005_100001 WO • Dri ve_T_0790809_L000 veTIM WO:Dsg ® 1.5X4 1.5X4 r • #LC = 78 WT • 433# ere to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer moat ascertain that Ore loads TC Live 20.00 psf 3X4 5X6 T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise 8-1 -13 5X6 noted. Bracing shown is for lateral support W components members only to reduce budding length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install F 5X6 8-1 -13 BC Live 0.00 psf 1.00 / 1.00 / 1.00 /l911• Bullding Components Group, Inc. 'ANSI/TPI 1', WICA 1'. Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4448 Northpark Dr. Ste. IOZ Colo. Spgs., CO 80907 (SCSI 1413) and'BCSI SUMMARY SHEETS' by WICA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onohio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located of 1111 191h Street, NW, Ste 800, Washington, DC 20036. SHIP DEFL RATIO: L/240 TC: L/240 3X8 3X4 1-55--101-3 13 2X1 3X4 6X8 7X8 3855 3X4 III 2X3 B3 BgX10 W:308 33-4-12 W:308 W:308 R:1268 R:2434 R:267 U:-144 40#1 40#1 U:-247 U:-67 3-5-8 1 45-6-8 3-0-0 STUB 10 11 12 13 14 15 16 17 STUB TYPICAL PLATE: 1X3 All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frow Alpine; or preceded by "WX" for TNHX 20 ga. or "H" for 16 ga. frow Truswal, positioned per Joint Detail Reports. Circled plates and false fraae plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Try s WARNING Read a0 notes on this sheet and give a copy of it to the Erecting Contractor. Mike and Marci Shadd This design N for an Individual building component not truss system. It has been based on specifications provided by the component manufacturer DIR: DIR: Drive_T_0790809_L00005_100001 WO • Dri ve_T_0790809_L000 veTIM WO:Dsg ® end done In accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions r • #LC = 78 WT • 433# ere to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer moat ascertain that Ore loads TC Live 20.00 psf Li veDu r L=1.2 5 P=1.2 5 utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf $noWDU r L=1.15 P=1.15 noted. Bracing shown is for lateral support W components members only to reduce budding length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Twswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 /l911• Bullding Components Group, Inc. 'ANSI/TPI 1', WICA 1'. Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4448 Northpark Dr. Ste. IOZ Colo. Spgs., CO 80907 (SCSI 1413) and'BCSI SUMMARY SHEETS' by WICA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onohio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located of 1111 191h Street, NW, Ste 800, Washington, DC 20036. Bldg Code' CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 3- 1-12 425 3.50 1.SO" 2x4 DFL #1 & Btr. 6-10 2 8- 0-0 2816 3.50" 2.63" BC 2x4 DFL #1 3 37- 0- 0 382 3.50" 1.50 WEB 2x4 DFL STANDARD 4 38- 8- 0 122 3.50" 1.50" 2x4 DFL #1 2-15 5 40- 4- 0 225 3.50" 1.50 GBL BLK 2x4 DFL STANDARD 6 42- 0- 0 2567 3.50" 1.50" IRC/IBCtruss plate values are based on 7 43-10- 0 207 3.50" 1.50" testingg and approval as required by IBC 1703 8 45- 7-15 221 3.50" 1.50" and AN and are reported in available 9 47- 5-15 195 3.50" 1.50" document ESR -1118. 10 49- 3-14 320 3.50" 1.50" Loaded for 10 PSF non -concurrent BCLL. 11 51- 6-15 453 10.12" 1.50" Loaded for 200 lb non -concurrent moving BCLL BRG REQUIREMENTS shown are based ONLY Mark all interior bearingQ locations. on the truss material at each bearing Install interior supports) before erection. MAX DEFLECTION (span) May use adequate staples for gable blocks. L/999 MEM 9-10 (LIVE) LC . BUILDING DESIGNER MUST VERIFY GABLE LOADS L= -0.18" D= -0.27" T= -00.45" AND EAVE LOADS, IF APPLICABLE. THIS TRUSS MAX DEFLECTION (cant) IS DESIGNED TO SUPPORT THE LOADS SPECIFIED L/266 MEM OL -1 (LIVE) LC BASED ON THE O.C. SPACING AND ANY L= -0.10" D= -0.04" T= -00.. 14" ADDITIONAL LOADS SHOWN. EX.WB DEF C1' T= CRITERIA:L/120 (+] gable bracing required @ 61" intervals, IN MEM 13- 1; TR 0.00" 9 CRITICAL MEMBER FORCES: if eXPPOSed t0 wind load applied to face. TC COMP.RItj / TENS.(OUR.) CSI See IiWBCG's Gable Bracing Details. OL -1 0(1.25)/ 62(1.253 (IT 1-2 / 887(1.25 0.66 Left Overhang(s) are not to be removed. 2-3 -2054 1.25 / 0.8 3 - 4 -OVERHANG(S) MAY BE SHORTENED UP TO 3" MAX.! .25 / 4-5 -2344 1 2330 1.25 0.811 / 0.56 Left Overhang Soffit loading - 0.0 psf 5-6 -2167 1.25 / 0.39 6-7 -1947 1.25 / 0.26 7-8 -2080 1.25 / 0.41 8-9 -2088 1.25 / 0.80 9-10 -1932 1.25 / 0.93 10-11 / 579(1.25) 0.99 11-12 -199(1.25)/ 327(1.25) 0.50 BC COMP.(DUR. / TENS. DUR. CSI 13-14 -57(1.25 / 18 1.60 0.40 14-15 -65S 1.25 / 0.49 15-16 / 190'(1 9071.25 0.67 16-17 / 1834 1.25 0.51 17-18 / 1834 1.25 0.37 18-19 / 1834 1.25 0.47 19-2020-2 1 / 1759 1.25 0.53 41 21-22 -413(1.25) 0.34 WB COMP. DUR./ TENS. WR. CSI 1-13 -4021.25/ 113 1.60 0.05 1-14 -7421.25/ 0.31 2-14 -252811.251/ 0.39 2-15 / 2714(1.25) 0.41 3-15 -930(1.25)/ 0.40 3-16 / 289(1.25) 0.12 4-16 -550(1.25)/ 0.47 6-16 / 591(1.25) 0.48 6-19 -3(1.60)/ 286(1.25) 0.43 8-19 -280(1.25)/ 0.24 9-19 / 346(1.25) 0.14 9-20 -1035(1.25)/ 0.67 10-20 / 2317(1.25) 0.94 10-21 -2278 1.25 / 0.46 11-21 -453 1.25 / 0.12 5-23 -6 1.25 / 153 1.25 0.06 17-25 7-24 81 1.25)% 295 1.25 0.04 18-26 -2(1.60)/ 180 1.25 0.07 truss ID: DF Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY 15THERS). Permanent bracing is required to prevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. PLATING BASED ON GREEN LUMBER VALUES. 20 psf Live Load applied to bottom chord in accordance with IBC/IRC requirements for attics with limited storage having a clear height >= 42" and clear width of >= 24". Qty: 1 UPLIFT REACTION(S) Support C&C Wind Non -Wind 1 -93 lb 2 -276 lb 3 -27 lb 4 -74 lb -119 lb 6 -257 lb 7 -3 lb 8 -3 lb 9 -14 lb -17 lb 10 -22 lb 11 -103 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bidg Width - 73.00 ft Mean roof height = 14.49 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 166 sqft Vertical members exposed to wind: 13- 1 --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 98.00 1- 0- 0 98.00 3- 0- 0 0.41 TC Vert 98.00 3- 0- 0 98.00 51- 0- 0 0.41 TC Vert 58.00 51- 0- 0 58.00 52- 0- 0 0.69 TC Vert 74.00 52- 0- 0 74.00 54- 0- 0 0.54 BC Vert 16.00 3- 0- 0 16.00 52- 0- 0 0.00 23-0-0 26-0-0 1 2 3 4 j67 8 9 10 11 12 4.00 6X6 -4.00 1.5X4 1.5X4q 1.5X4 115X4 3.5X4 T 1.5X4 1.5X4 5X8 1.5X4 8-1j-13 6X6 H0610 11 SHIP 1-13 3X6 2.5X6 --------------- m 2X3 4X8 5X8 1.5X4 5X8 4X5 0-3-13 81 1.5X4 4X8 3.W6 5-0-0 34- 3 3-aoHO as-ao 1� STUB 13 14 15 16 1718 19 20 21 22 TYPICAL PLATE: 1X3 OVER SUPPORT AS SHOWN tr All connector plates are Trusrral 20 ga. unless preceded by "Il" for Nave 20 ga., "NS" for NS 20 ga., "S" for SS 18 ga. frac Alpine; V or preceded by "RX" for Tl 20 ga. or "N" for 16 ga. from Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frase plates arc positioned as sham above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Trur Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer Drive_T_0790809_L00005_]00001 • Dri ve_T_0790809_L000 ®DIR: and e in accordance with the anent versions of TPI and AFPA design standards. No responsibilityis assumed for dimensional accuracy.WO don . Dimensions Dsgn r • TM #LC = 105 WT ' ' SD$# are to be verified by the component manufacturer andfor building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utiiited on this design meet or exceed the loading imposed by the local building code and the particular applica0on. The design assumes that the top Mord T R U S WA L Is laterally braced by the roof or floor sheathing and the bottom Mord is laterally braced by a rigid sheathing materiel directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing Mown is for lateral support of components members only to reduce buckling length. This component ..It not be placed in any TC Dead 9.00 psf Rep Mb r Bind / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% end/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: *Joint and Cutting Detail Repons' evailable as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 IM Building Components Group, Inc. 'ANSI/TPI 1', VVTCA F- Wood Truss Council ofAmerice Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spits., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street. NVV. Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO' L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D 1 0- 3- 4 1218 3.50" 1.50" 2 23-10- 4 1497 3.50" 1.60" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 3-4 (LIVE) LC 1 L= -0.12" D= -0.20" T= -0.32" CRITICAL MEMBER FORCES: TC COMP. WR. / TENS.(DUR.) CSI 1-2 -3169 1.25 / 0.38 2-3 -2505 1.25 / 0.39 3-4 -2504 1.25 / 0.39 4-5 -3678 1.25 / 0.50 8C COMP.(DUR.)/ TENS. WR, CSI 6-7 / 2971 1.25 0.57 7-8 / 2965 1.25 0.80 8-9 / 3430 1.25 0.88 9-10 / 3455 1.25 0.66 WB COMP.(DUR.)/ TENS. WR. CSI 2-7 / 281 1.25 0.11 2-8 -675(1.25)/ 177 1.60 0.46 3-8 / 949 0.90 0.54 4-8 -1165(1.25)/ 0.79 4-9 / 586(1.25) 0.24 TC 2x4 DFL #1 BC 2x6 DFL #2 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testingg and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Permanent bracing is required to prevent rotation/toppling. Refer to gr and ANSI/TPI 1. Truss ID: E1 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAILf FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.S" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this trusst per IBC/IRC requirements for attics with limited storage. 11-10-8 12-0-0 1 2 3 4 5 4.00 6x6 a.0o B1 B2 W:308 W:308 R:1218 R:1497 U:-166 U:-204 0-1-8 i 23-10-8 Pl_� STUB 6 7 8 9 10 __.--'-- ----(qty: -_1_ UPLIFT REACTION(S) : Support CB{ Wind Non -Wind 1 -166 lb 2 -204 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line - No Exp Category - C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 12.16 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 69 sqft --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 58.00 0- 1- 8 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 0.54 BC Vert 16.00 0- 1- 8 16.00 9- 0- 0 0.00 BC Vert 96.00 9- 0- 0 96.00 19- 0- 0 0.00 BC Vert 16.00 19- 0- 0 16.00 24- 0- 0 0.00 S 0-3-13 t .V'. r..1. 101\1 API - 4.1 .11 SHIP All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "MX" for TWU 20 ga. or "M" for 16 Be. from Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru p Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd DIR : D r i ve_T_0790809_L00005_100001 This des is fru an individual building w orient not truss tem. 11 has been based on specifications provided the component design g mp sys p p by mponentmuracy.lDim W0: Drive_T_0790809-L000 ® and done In accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC - 46 WT: 149# T R U S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Smcing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% andlor cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Tmswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 IM Building Components Group, Inc. 'ANSI7TPI 1', W1CA V- Wood Truss Council of America Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION' - BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4445 Northpark D, Sm. 107, Colo. Spgs., CO 80907 (SCSI 1.03) and 'SCSI SUMMARY SHEETS' by WrCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin53719. The American Forest and paper Association (AFPA)islocated at111119thStreet. NW, Ste 800.Washington, DO20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence Truss ID: E2 Qtv: 1 BRG X -LOC REACT SIZE REQ'D 1 0- 3- 4 1024 3.50" 1.50" 2 23-10- 4 1171 3.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 7-8 (LIVE) LC 33 L= -0.24" D- -0.34" T= -0.57" CRITICAL MEMBER FORCES: TC COMP. OUR. / TENS.(OUR.) CSI 1-2 -2545 1.25 / 0.30 2-3 -2287 1.25 / 0.44 3-4 -2313 1.25 / 0.41 4-5 -2581 1.25 / 0.33 BC COMP.(DUR.)/ TENS. OUR. CSI 6-7 / 2376 1.25 0.76 7-8 / 1579 1.25 0.95 8-9 / 2408 1.25 0.92 NB COMP. DUR .)/ TENS. OUR. CSI 2-7 -345 1.25)/ 19111:601 1.60 0.06 3-7 / 7691.25 0.31 3-B125 0.32 4-8 -363(1.25)/ 174 0.06 TC 2x4 DFL #1 BC 2x4 DFL #1 2x4 DFL #1 & Btr. 6-8 WEB 2x4 DFL STANDARD THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 4-32-13 1 3X8 = 0-4-5 268 - Homewood Trus TRUSWAL ® SYSTEMS /lr81V Building Components Group, Inc. Odds Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 TRUSPLUS 6.0 VER: T6.5.9P Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testinand approval as required by IBC 1703 and AN?I/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Permanent bracing is regwired to prevent rotation/toppling. Refer to BCSI and ANSI/TPI 1. 11-10-8 12-0-0 1 2 3 4 5 4.00 6X6 UPLIFT REACTION(S) : Support C&C3Wind Non -Wind lb 2 -159 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line No Exp Category C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 12.16 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 55 sgft --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 58.00 0- 1- 8 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 0.54 BC Vert 16.00 0- 1- 8 16.00 8- 0- 0 0.00 BCVert 51.00 8- 0- 0 51.00 16- 0- 0 0.00 BC Vert 16.00 16- 0- 0 16.00 24- 0- 0 0.00 B1 B2 W:308 W:308 R:1024 R:1171 U: 139 U:-159 0-1-8 23-10-8 STUB 6 7 8 9 All connector plates are Trusual 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for NS 20 ga., "5" for SS 18 Be. frow Alpine; or preceded by "NX" for TWNX 20 ga. or "N" for 16 ga. froom Troswal, positioned per Joint Detail Reports. Circled plates and false frawe plates are positioned as shown above. Shift gable stud plates to amid overlap with structural plates (or staple). VVH KIVIN V Read all notes on this sheet and give a copy of it to the Erecting Contractor. This design is for an individual building component not truss system. II has been based on specifications provided by the component manufacturer and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise noted. Bracing shown is for lateral support of components members only to reduce buclding length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, Install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software, 'ANSI/TPI 1', WTCA V. Wood Truss Council of America Standard Design Responsibilities, 13UILDING COMPONENT SAFETY INFORMATION - (BCSI 1.03) 8nd'SCSI SUMMARY SHEETS' by W1CA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Gnofrio Drive, Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 19th Street, NW, Ste 900, Washington, DC 20036. r June 30, 201 CIV1It. 10/15/2009 Cust: Mike and Marci Shadd DIR: Drive_T_0790809_L00005_100001 W0: Drive -T_0790809 -L000 Dsgnr: TM #LC = 46 wr: 123# TC Live 20.00 psf LiveOur L=1.25 P=1.25 TC Snow(Pf) 0.00 psf SnowDur L=1.15 P=1.15 TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens BC Live 0.00 psf 1.00 / 1.00 / 1.00 BC Dead 8.00 psf O.C.Spacing 2- 0- 0 Bldg Code: CBC -07 IDEFL RATIO: L/240 Job Name: Shadd / New Residence Truss ID: E3 Qtv: 7 BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 0- 1-12 1176 3.50" 1.50" BC 2x4 DFL #1 2 23-10- 4 1176 3.50" 1.50" 2x4 DFL #1 & Btr. 6-8 BRG REQUIREMENTS shown arebased ONLY WEB 2x4 DFL STANDARD on the truss material at each bearing THIS DESIGN IS THE COMPOSITE RESULT OF MAX DEFLECTION (span) : MULTIPLE LOAD CASES. L/999 MEM 7-8 (LIVE) LC 34 IF THIS TRUSS IS CARRIED IN A HANGER, THAT L= -0.23" D= -0.33" T= -0.57" HANGER IS BASED ON 1.5" HANGER NAILS FOR CRITICAL MEMBER FORCES: 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY Tc COMP. OUR. / TENS.(DUR.) CSI 1-2 -2596 1.25 / 0.34 CARRYING MEMBERS. IF 2.5" GUN NAILS ARE 2-3 -2330 1.25 / 0.41 USED, THE HANGERS MUST BE RE-EVALUATED 3-4 -2328 1.25 / 0.41 (BY OTHERS). 4-5 -2596 1.25 / 0.34 PLATING BASED ON GREEN LUMBER VALUES. BC COMP.(DUR.)/ TENS. (DUR. CSI 20 psf bottom chord live load NOT required 6-7 / 2424(1.253 0.78 on this truss, per IBC/IRC requirements for 7-8 / 1595((1.253 0.94 attics with limited storage. 8-9 / 2423 1.25 0.92 HB COMP. DUR. / TENS. DUR. CSI 2-7 -364 1.25 / 174 1.60 0.06 3-7 / 792 1.25 3-8 0.32 / 790 1.25 0.32 4-8 -365(1.25)/ 174 1.60 0.06 Designed per ANSI/TPI1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Permanent bracing is regwired to prevent rotation/toppling. Refer to BCSI and ANSI/TPI 1. 12-0-0 12-0-0 1 2 3 4 5 6x6 -4.00 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -146 lb 2 -146 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Categoryy = C Bldg Length = 72.00 ft, Bidg Width = 73.00'ft Mean roof height = 12.16 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 56 sqft ----------LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 0.54 BC Vert 16.00 0- 0- 0 16.00 8- 0- 0 0.00 BC Vert 51.00 8- 0- 0 51.00 16- 0- 0 0.00 BC Vert 16.00 16- 0- 0 16.00 24- 0- 0 0.00 B1 B2 W:308 W:308 R:1176 R:1176 U:-146 U:-146 F_a0 i Fg_� 24-0-0 6 7 8 9 All connector plates are Twswal 20 ga. unless preceded by "M" for Nave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "MX" for TWMX 20 ga. or "H" for 16 ga. froom Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 framere plates apositioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tr�ufs Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd DIR : D r i ve_T_0790809-L00005-700001 This designis for an individual building w onent not truss tem. It has been based on s cificetims provided the co g cop sys pe p by component W0: Drive ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional ecwreq. Dimensions accuracy. Dim are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads -T -0790809_L000 Dsg n r : TM #LC = 46 WT: 127# utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 9.00 pSf Rep Mbr Bnd / Comp / Tens ® SYSTEMS environment that will cause the motsturecontent ofthe mod toexceed 19%and/or cause connector plate conosion. Fabricate, handle, Install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 /lI19/ Building Components Group, Inc. •ANSUTPI 1', WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf O. C. Spaci ng 2- 0- 0 Id45 NorthpaM Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI "3) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated a1111119thStreet. NW, Ste 800,Washington, DC20036. Bldg Code' CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 UFL #1 1 0- 1-12 1176 3.SO" 1.50" BC 2x4 DFL #1 2 23-10- 4 1176 3.50" 1.50" 2x4 DFL #1 & Btr. 7-9 BRG REQUIREMENTS shown are based ONLY WEB 2x4 DFL STANDARD on the truss material at each bearing THIS DESIGN IS THE COMPOSITE RESULT OF MAX DEFLECTION (span) : MULTIPLE LOAD CASES. L/999 MEM 9-10 (LIVE) LC 40 IF THIS TRUSS IS CARRIED IN A HANGER T L= -0.24" D= -0.12" T= -0.36" HANGER IS BASED ON 1.5" HANGER NAIB F CRITICAL MEMBER FORCES: 1 -PLY AND 3" HANGER NAILS FOR MULTI -PL TC COMP. (DUR. / TENS.(DUR.) CSI 1-2 -2559(1.253/ 0.40 CARRYING MEMBERS. IF 2.5" GUN NAILS AR 2-3 -2355(1.25)/ 0.36 USED, THE HANGERS MUST BE RE-EVALUATED 3-4 -2030(((1.253)/ 0.52 (BY OTHERS). 4-5 5-6 1.25 -2357 1 . 25 -2557 / / 10/15/2009 0.4o36 0. Permanent bracing is regwired to Cust: Mike and Marci Shadd g mpions not truss system. It has been based on specifications provided by the This designIs for an Individual co DIR: Drive_T_0790809_L00005-700001 WO • Dri ve_T_0790809_L000 prevent rotation/toppling. Refer to BC COMP.(DUR.)/ TENS.( OUR . CSI BCSI and ANSI/TPI 1. 7-8 / 238z(1.z53 0.78 PLATING BASED ON GREEN LUMBER VALUES. B-9 / 2030 1.zs 0:" 20 psf bottom chord live load NOT required 9-10 / 2380 1.xs 0.92 on this truss, per IBC/IRC requirements for I conP.(DUR.)/ DUR. TENS.11:601 Csi attics with limited storage. 2-8 3-8 -233(1.25)/ / 1671.60 5601.25 BC Dead 0.05 0.23 O.C.Spaeing 2- 0- 0 4-9 / 559125 0.23 TRUSPLUS 6.0 VER: T6.5.9P 5-9 -236(1.25)/ 168 DEFL RATIO• L/240 TC: L/240 0.05 `J Truss ID: E4 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Drainage must be provided to avoid ponding. Continuous lateral bracing attached to flat TC as indicated. Lumber must be structural grade. Brace @ 24" o.c. unless noted. 9-10-15 9-10-15 1 2 3 4 5 6 a.00 4-0-0 -a.00 Qty: 1 Thisdesign based on chord bracing applied per the following schedule: max o.c. from to TC 24.00" 9-10-15 14- 0- 0 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -173 lb 2 -173 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No,Exp Category = C Bldg Length = 72.00 ft, Bdg Width = 73.00 ft Mean roof height = 11.81 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 56 sqft --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 0.54 BC Vert 16.00 0- 0- 0 16.00 8- 0- 0 0.00 BC Vert 51.00 8- 0- 0 51.00 16- 0- 0 0.00 BC Vert 16.00 16- 0- 0 16.00 24- 0- 0 0.00 B1 B2 W:308 W:308 R:1176 R:1176 U:-173 U:-173 X2-0-0 i F2:2_� 24-0-0 7 8 9 10 4- 5 , SHIP 2 0-3-13 Si All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "MX" for TWWX 20 ga. or "N" for 16 ga. frac Trvswal, positioned per Joint Detail Reports. circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Troup Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd g mpions not truss system. It has been based on specifications provided by the This designIs for an Individual co DIR: Drive_T_0790809_L00005-700001 WO • Dri ve_T_0790809_L000 ® accuracy. Dim dimensional end done b accordance with Me anent versions of TPI end AFPA design standards. No responsibility is assumed for dimensional eccurary. Dimensions Dsgn r • TM #LC = 46 WT • 120# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading imposed by the local building code end the particular application. The design assumes that the lop chord T R U S WA L is laterally braced by the roof or fear sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC SnDW (Pf) 0.00 psf SnOWDU r L=1.15 P=1.1$ noted. Bracing shown is for lateral support of components members only to reduce budding length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 AM Building Components Group, Inc. 'ANSVrPI 1% WICA V- Wood Truss Council of America Standard Design Responsibilities, 13UILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf O.C.Spaeing 2- 0- 0 4115 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) ond'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located of 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet. NW, Ste 800,Washington, DC20036. Bldg Code: CBC -07 DEFL RATIO• L/240 TC: L/240 Job Name: Shadd / New Residence ^� BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL ;;I1 0- 1-12 1036 3.50" 1.50" BC 2x4 DFL #1 2 23-10- 4 1036 3.50" 1.50" WEB 2x4 DFL STANDARD BRC REQUIREMENTS shown are based ONLY Refer to Joint QC Detail Sheets for on the truss material at each bearing Cq factors and Rotational Tolerances. MAX DEFLECTION (span) : IRC/IBC truss plate values are based on L/911 MEM 7-8 (LIVE) LC 34 testing and approval as required by IBC 1703 L= -0.31" D- -0.15" T= -0.47" and AN and are reported in available CRITICAL MEMBER FORCES: document ESR -1118. TC COMP. DUR. / TENS. DUR. CSI Loaded for 10 PSF non -concurrent BOLL. 1-2 -2044 1.25 / 31111.601 1.60 0.56 2-3 -1946 1.25 / 3141.60 0.29 Loaded for 200 lb non -concurrent moving BCLL 3-4 -194a 1.25 / 3141.60 0.29 Drainage must be provided to avoid ponding. 4-5 -2045 1.25 / 310 0.56 PLATING BASED ON GREEN LUMBER VALUES. ac cOMP.((DUR.>>)/ TEN.1,1(1UR. csi 20 pf bottom chord live load NOT required 6-7 -253(1.60)/ 1887(1.253 0.67 on this truss, per IBC/IRC requirements for 7-8 -329 1(1.603/ 2190(11.253 0.81 attics with limited storage. 8-9 -253 1.60 / 1888 1.25 0.67 NB COMP.(DUR.)/ TENS. DUR. CSI - 2-7 / 355 1.25 0.14 3-7 -278(1.25)/ 118 1.60 0.13 3-8 -28001.25)/ 118 1.60 0.13 4-8 / 355 1.25 0.14 7-10-15 1 -Truss ID: E5 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Continuous lateral bracing attached to flat TC as indicated. Lumber must be structural grade. Brace @ 24" o.c. unless noted. l 7-10-15 1 3 4 5 4.00 i 8-0-0 -4.00 Qty: 1 This design based on chord bracing applied per the following schedule: max o.c. from to TC 24.00" 7-10-15 16- 0- 0 UPLIFT REACTION(S) Support C&C Wind Non -Wind 1 -229 lb 2 -229 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category C Bldg Length - 72.00 ft, Bldg Width = 73.00 ft Mean roof height = 11.48 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 48 sqft B1 B2 W:308 W.308 R:1036 R:1036 U:-229 U:-229 P_� 24-0-0 6 7 8 9 3-7-5 = I SHIP 0-313 -- �1 r June 30,201 CMI. A71 connector plates are Truswal 20 ga. unless preceded by "N" for Nave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. fres Alpine; or preceded by "NX" for TNNX 20 ga. or "H" for 16 ga. frac Trusnal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frasre e plates apositioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 768 - Homewood Trur Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd design is for an individual building component not ss system. It hes been based on specifications provided by me component manufacturer DIR: Drive_T_0790809_L00005_100001 WO � Dr i ve_T_0790809_L000 ®trussThis and done In accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC = 46 Vr: 123# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed In any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ®SYSTEMSenvironment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install BC Live 0.00 1.10 1.10 1.10 and brace this friss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output born Truswal software. psf / / AM Building Components Group, Inc. 'ANSIrrPI 1', WTCA V- Wood Truss Council of America Standard Design Responsibil'nies, BUILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf 0. C. Spaei ng 2- 0- O 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) end'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association AFPA) is located at I I I I 19th Street, NW, Ste 800. Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC' L/240 Job Name: Shadd / New Residence Y Truss ID: E6 BRG X -LOC REAL! SIZE REQ -0 1 0- 1-12 1690 3.50" 1.50" 2 23-10- 4 1690 3.50" 1.50" BRIG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 3-4 (LIVE) LC 1 L= -0.24" D= -0.18" T= -0.42" CRITICAL MEMBER FORCES: TC COMP. DUR. / TENS. DUR. CSI 1-2 -4071 1.25 / 311 1.66 0.13 2-3 -6073 1.25 / 444 1.60 0.67 3-4 -6073 1.25 / 444 1.60 0.67 4-5 -4071 1.25 / 311 1.60 0.13 BC COMP. OUR. / TENS. DUR. CSI 6-7 -260 1.60 / 3821 1.25 0.37 7-8 -2S0 1.60 / 3856 1.25 0.48 8-9 -250 1.60 / 3856 1.25 0.48 9-10 -260 1.60 / 3821 1.25 0.37 WB COMP.(DUR.)/ TENS. DUR. CSI 2-7 / 365 1.25 0.08 2-8 -148(1.60)/ 2273 1.25 0.46 3-8 -818((1.253/ 136 1.60 0.05 4-8 -148 1.60 / 2274 1.25 0.46 4-9 / 365 1.25 0.08 TC 2x4 DFL #1 BC 2x4 DFL #1 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL + + + + + + + + + + + + + + + + + + + + + + Nail pattern shown is for PLF loads and point loads converted to PLF loads only. Concentrated loads MUST be distributed to each ply equally. Multi -ply with hangers are based on hanger nails using 3.0" nails min. into the carrying member. If shown, use additional fasteners for point loads from the back plys, distributed symm. in the chords, within 12' of hanger flange. Use any other approved detail (by others). IF 2.5' GUN NAILS ARE USED, ANY NAIL CLUSTER AMOUNTS SHOWN MUST BE INSTALLED FROM THE FRONT AND BACK FACE EQUALLY (TOTAL NAILS = DOUBLE THE AMOUNT SHOWN). 10d = 10d NAILS, SDS = Simpson SDS screws or equivalent substitute. (•) = Special Connection Req. (by others) ++++++++++++++++++++++ Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Drainage must be provided to avoid ponding. Permanent bracing is required to prevent rotation/toppling. Refer to SCSI and ANSI/TPI 1. Continuous lateral bracing attached to flat TC as indicated. Lumber must be structural P? Brace @ 24" o.c. unless noted. PLATING BASED ON GREEN LUMBER VALUES. 2 -PLY! Nail w/lOd COMMON, sta22ered(pper NDS) in: TC- 2 BC- 2 WEBS- 2 PER FOOT! ­ Cluster screws, if shown are 3" long: 20 Dsf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 2 This design based on chord bracing applied per the following schedule: max o.c. from to TC 24.00" 5-10-15 18- 0- 0 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -247 lb 2 -247 lb This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length - 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 11.14 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding TributaryArea = 83 sqft --LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 6- 0- 0 0.69 TC Vert 111.77 6- 0- 0 111.77 18- 0- 0 0.69 TC Vert 58.00 18- 0- 0 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 0.54 BC Vert 30.83 0- 0- 0 30.83 24- 0- 0 0.00 ...Type... lbs X.Loc LL/TL Fastener TC Vert 0.0 0- 1-12 1.00 TC Vert 105.8 6- 0- 0 1.00 TC Vert 47.6 6- 0- 0 0.00 TC Vert 105.8 18- 0- 0 1.00 TC Vert 47.6 18- 0- 0 0.00 TC Vert 0.0 23-10- 4 1.00 5-10-15 5-10-15 2-PLYS 11 3 4 5 REQUIRED 4.00 I 12-0-0-153# 1153# 4.00 1 .t 5X8 1.5X3 5X8 T • , �� ' i� 2" 7 3.5X5 3za�.5X5 2-11-5 _ = 1I SHIP 0-3-13 1.5X3 6X8 1.5X3 0-3-13 B1 B2 W:308 W:308 RAND RAND U:-247 U:-247 24-0-0 6 7 8 9 10 All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "RS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "MX" for TWMX 20 ga. or "H" for 16 ga. frost Trussral, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 framere plates apositioned as shown above. Shift gable stud plates to amid overlap with structural plates (or staple). 268 - Homewood Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd (CA) This g mponenf not truss system. It hes been based on specifications provided by the component manufacturer This designla for an Individual building cc DIR: Drive -T -0790809-L00005100001 W0: Dri Ve_T_0790809_L000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions Dsg n r : TM #LC = 46 WT: 129# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain Ilial the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 Wlized an this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral supPori of components members only to reduce buckling length. This component ..It not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports'available as output from Tmswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 IM Building Components Group, Inc. 'ANSI/TPI 1', WTCA 1' - Wood Truss Council of America Standard Design Responsibilhies,'BUILDING COMPONENT SAFETY INFORMATION' - BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WrCA and TPI. The Truss Plate Institute (TPI) is located at 583 O'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.91D Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at 1111 1 9th Street. NW, Ste 800. Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 0- 1-12 1476 3.50" 1.57" BC 2x4 DFL #1 2 23-10- 4 1476 3.50" 1.57" WEB 2x4 DFL STANDARD BRGREQUIREMENTS shown are based ONLY GBL BLK 2x4 DFL STANDARD on the truss material at each bearing THIS DESIGN IS THE COMPOSITE RESULT OF MAX DEFLECTION (span) : MULTIPLE LOAD CASES. L/999 MEM 7-8 (LIVE) LC 33 IF THIS TRUSS IS CARRIED IN A HANGER THAT L= -0.24" D= -0.22" T= -0.46" HANGER IS BASED ON 1.5" HANGER NAILf FOR CRI11CAL MEMBER FORCES: TC COMP. OUR. / TENS.(DUR.) CSI 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY 1-2 -33oa I.2s / 0.64 CARRYING MEMBERS. IF 2.5" GUN NAILS ARE 2-3 -2844 1.zs / 0.67 USED, THE HANGERS MUST BE RE-EVALUATED 3-4 -2843 1.25 / 0.67 (BY OTHERS). 4-5 -3308 1.25 / 0.64 May use adequate staples for gable blocks. BC 6-7 COMP.(DUR.)/ TENS.(WR. / 3078(1.253 CSI 0.95 BUILDING DESIGNER MUST VERIFY CABLE LOADS AND EAVE LOADS, IF APPLICABLE. THIS TRUSS 7-B / 2007 1.x5 O.B5 IS DESIGNED TO SUPPORT THE LOADS SPECIFIED e-9 / 3078 1.25 0.95 BASED ON THE O.C. SPACING AND ANY WB COMP.(DUR.)/ TENS.(DUR.) CSI ADDITIONAL LOADS SHOWN. z-7 -645 1.28 / 0.11 [+] gable bracing required @ 61" intervals, 3-7 / 841(1.zs) 0.34 if expposed to wind load applied to face. 3-B 4-8 / B41 1.25 -646(1.25)/ .34 0.34 0.11 See ,P Cable Bracing Details. Truss ID: EG Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Permanent bracing is regwired to prevent rotation/toppling. Refer to BCSI and ANSI/TPI 1. PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 12-0-0 12-0-0 1 2 3 4 5 4.00 -4.00 6x6 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -183 lb 2 -183 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location Not End Zone Hurricane/Ocean Line No Exp Category - C Bldg Length - 72.00 ft, Bidg Width 73.00 ft Mean roof height = 12.16 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 72 sqft ----------LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.Loc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 1- 0- 0 0.69 TC Vert 98.00 1- 0- 0 98.00 23- 0- 0 0.41 TC Vert 58.00 23- 0- 0 58.00 24- 0- 0 0.69 TC Vert 74.00 24- 0- 0 74.00 26- 0- 0 O.S4 BC Vert 16.00 0- 0- 0 16.00 24- 0- 0 0.00 131 W:308 R:1476 U:-183 24-ao 6 7 8 9 All connector plates are Trusral 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frost Alpine; or preceded by "KK" for TMIX 20 ga. or "H" for 16 ga. fres Trusrral, positioned per Joint Detail Reports. Circled plates and false frase plates are positioned as shorn above. Shift gable stud plates to avoid overlap with structural plates (or staple). TYPICAL PLATE: 1X3 62 W:308 R:1476 U:-183 baORA,� •• , �l r June 30:12011 CIVIs. 10/15/2009 268 - Homewood T�r�u�s ® WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. This design Is for an Individual co tin g component not truss system. It has been based on specifications provided by the component manufacturer end done in accordance with me anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions ere to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dust: MikeShadd ve and Marc9080 LOOOO OIR: Drive_T_0790809_L000OS_]00001 WO • Dri ve_T_0790809_L000 Dsgn r : TM #LC = 46 WT: 180# TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading imposed by me local building code and the particular application. The design assumes that the top chord T R U S WA L ® SYSTEMS IM Building Components Group, Inc. Is laterally braced by the roof or Bear sheathing and the bottom tlrord is laterally braced by a rigid sheathing material directly attached, unless otherwise noted. Bracing shown is for lateral support of component members only to reduce budding length. This component shall not be placed in any environment that will cause the moisturecontent ofthe wood toexceed 19%and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: *Joint and Cutting Detail Reports' available as output from Truswal software, •ANSITPI 1', WICA V- Wood Truss Council of America Standard Design Responsibilities.'BUILDING COMPONENT SAFETY INFORMATION'- TC SnOw(Pf) 0.00 psf TC Dead 9.00 psf BC Live 0.00 psf BC Dead 8.00 psf SnOWDU r L=1.15 P=1.15 Rep Mbr Bnd / Comp / Tens 1.00 / 1.00 / 1.00 0. C. Spaei ng 2- 0- 0 4445 Nordrpark Dr. Ste. 102, Colo. Spgs., 0080907 TRUSPLUS 6.0 VER: T6.5.9P (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WfCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, Wisconsin 53719. The American Forest and Paper Association (AFPA)tlocated at111119thStreet. NW. Ste 800,Washington. OC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence Truss ID: G1 _ Qtv: 2 BRC X -LOC REACT SIZE REQ'D 1 0- 1-12 751 3.50" 1.50" 2 16- 1-12 751 3.50" 1.50" BRC REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 6-7 (LIVE) LC 26 L= -0.19" D= -0.07" T- -0.26" CRITICAL MEMBER FORCES: TC COMP. OUR / TENS. OUR. CSI 1-2 -1252 1.25 / 226 1.60 0.33 2-3 -996 1.25 / 163 1.60 0.23 3-4 -996 1.25 / 163 1.60 0.23 4-5 -1252 1.25 / 220 1.60 0.33 BC COMP.(DUR. / TENS. DUR. CSI 6-7 -180(1.60 / 1151 1.25 0.62 7-8 -180(1.60 / 1151 1.25 0.61 WB COMP. Th / TENS. OUR CSI 2.7 -3201.25 / 135 1.60 0.06 3-7 1.60 / 580 1.25 0.24 4-7 --3280111.25 / 135 1.60 0.06 TC 2x4 DFL #1 BC 2x4 DFL #1 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 316 2 0-3-13 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.S" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). 8-1-12 1 8-1-12 1 2 3 4 5 4.00 6X6 4.00 61 62 W:308 W:308 R:751 R:751 U:-191 U: 191 2_0-0 200 ' l 16-3-8 6 7 8 All connector plates are Trvswal 20 ga. unless preceded by "H" for Have 20 ga., "HS" for US 20 ga., "S" for SS 18 ga. fres Alpine; or preceded by "HX" for THHX 20 ga. or "H" for 16 ga. fros Truswal, positioned per Joint Detail Reports. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). UPLIFI' REACTION(S) : Support C&C Wind Non -Wind 1 -191 lb 2 -191 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location Not End Zone Hurricane/Ocean Line No Exp Category C Bldg Length = 72.00 ft, Bidg Width 73.00 ft Mean roof height = 11.52 ft, mph 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 33 sqft 3 -4 SHIP 2 0-3-13 r a Tip y `F 1jo/V 268 - Homewood MrA fs WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Gust: Mike and Marci Shadd This design is for an individual building component not truss system. It hes been based on specifications provided by the component manufacturerWO DIR: Drive_T_0790809_L00005_J00001 • Dr i ve_T_0790809_L000 ' ® and done In accordance with the current versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC 39 WT: 83# are to be verified by the componem manufacturer andfor building designer prior to labricabon. The building designer mist ascertain that the loads = utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.2 5 P=1.2 5 T R U S WA L is laterally braced by the roof or Door sheathing and the bottom chord Is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the moisture contenl of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mbr Bind / Comp / Tens and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Traswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSI/TPI I% WTCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 O'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association(AFPA) is located at 111119th Street, NW, Ste 800, Washington, DC 20036. Bldg Code: CBC -07 nFFI RATTl3• I /7dn Tr- i /'2dn Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D TC 2 x 4 DFL #1 1 0- 1-12 603 3.S0" 1.50" BC 2x4 DFL #1 2 16- 1-12 603 3.50" 1.50" WEB 2x4 DFL STANDARD BRG REQUIREMENTS shown are based ONLY Refer to Joint QC Detail Sheets for on the truss material at each bearing Cq factors and Rotational Tolerances. MAX DEFLECTION (span) IRC/IBC truss plate values are based on L/999 MEM 6-7 (LIVE) LC 26 testing and approval as required by IBC 1703 L= -0.19" D= -0.07" T= -0.26" and ANSI/TPI and are reported in available CRITICAL MEMBER FORCES: document ESR -1118. 7C COMP. DUR. / TENS. DUR. C33 Loaded for 10 PSF non -concurrent BCLL. Si 1-2 -1252 1.25 / 23711.6001 1.60 0.33 2-3 -996 1.25 / 1821.60 0.23 Loaded for 200 lb non -concurrent moving BCLL 3-a -996 1.25 / 16z1.6 0.23 PLATING BASED ON GREEN LUMBER VALUES. 4-5 -1252 1.x5 / 237 0.33 20 pf bottom chord live load NOT required BC COMP.(011t / TENS. (DUR.) CSI on this truss, per IBC/IRC requirements for 6-7 -189(1.603/ 1151(1.253 0.62 attics with limited storage. 7-8 -18901.60 / 1151(1.25 0.61 WB COMP. DUR. / TENS. DUR. CSI 2-7 -326 1.25 / 134 1.60 0.06 3-7 -98 1.60 / 580 1.2S 0.24 4-7 -320 1.25 / 134 1.60 0.06 T 2.5X6 0-3-13 B1 W.308 R:603 UA 12 Truss ID: G1A Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). 8-1-12 i 8-1-12 1 2 3 4 5 4.00 6X6 4.00 16-3-8 6 7 8 -Qtv:� 2 UPLIFT' REACI'ION(S) : Support C&C Wind Non -Wind 1 -112 lb 2 -112 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line No Exp Category = C Bldg Length - 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 11.52 ft, mph 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 33 sqft 3 SHIP iX6 0-3-13 B2 W.308 R:603 LIA 12 I- CA N June 30, 2011 CIVIL All connector plates are Truswal 20 ga, unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "MX" for TW9X 20 ga. or "N" for 16 ga. fret Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru s R Read all notes on this sheet and give a copy of it to the Erecting Contractor. Mike and Marci shads (CA. gn g component not truss system. It has been based on specifications provided by the component manufacturer This design is for an Individual rA DIR:Cust DIR: Drive_T_0790809_L00005_J00001 WO: WO • Dr i ve_T_0790809_L000 veTIM ® current versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions and done In accordance with the an r • #LC = 39 ' 7 5# are to be vedfied by the component manufacturer and/or building designer prior to fabrication. The building designer moat ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bradng shown Is for lateral support of components members only to reduce budding length. This component shall not be placed in any Dead 9.00 psf Rep Mb r Brill / Comp / Tens ®TC SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate conosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truawal software, BC Live 0.00 Sf P 1.15 1.10 1.10 / / 07W Building Components Group, Inc. 'ANSI/TPI 1', WTCA V- Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION'- BC Dead 8.00 psf 0. C. Spaci ng 2- O- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., Co 80907 (SCSI 1-03) and •BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet. NW, Ste 800,Washington.DO20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence CRITICAL MEMBER FORCES: TC 2x4 DFL #1 BC 2x4 DFL #1 GBL BLK 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL May use adequate staples for gable blocks. BUILDING DESIGNER MUST VERIFY GABLE LOADS AND EAVE LOADS, IF APPLICABLE. THIS TRUSS IS DESIGNED TO SUPPORT THE LOADS SPECIFIED BASED ON THE O.C. SPACING AND ANY ADDITIONAL LOADS SHOWN. [+] gable bracing required 0 61" intervals, if exposed to wind load applied to face. See IiWBCG's Gable Bracing Details. 3 2 0-3-13 44-0-0 4-0-0 Truss ID: GG Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Desigger must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIL FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 4-0� 16-3-8 8-1-12 1 8-1-12 1 1 2 3 4 5 6 7 8 9 10 11 4.00 3.5X4 4.00 OVER CONTINUOUS SUPPORT --- - Qtv: .. 1.— This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No,Exp Category = C Bldg Length = 72.00 ft, Bdg Width 73.00 ft Mean roof height = 11.52 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 33 sgft 3-114 SHIP 0-3-13 1 2-0-01l I 16-3-8 �D� . 627 N M 79 12 13 14 15 16 17 18 1� 20 21 4-0-0 1 N2 C4 O 40-0 x June 30,201 Q D 9 4-0-0 163-8lOlCD_ 1 Q TYPICAL PLATE: 1.5X3 OVER CONTINUOUS SUPPORT 'q C l C of CALIF A77 connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. her Alpine; or preceded by "AIX" for TWWX 20 ga. or "N" for 16 ga. fres Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frasre e plates apositioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tru s Read all notes on this sheet and give a co of it to the Erecting Contractor. Cust: Mike and Marci Shedd (CAT 9 PY 9 DIR: Drive_T_0790809_L00005_]00001 ® This design Is for an ce with t building component not baso system. It hes been based on spotimstions Provided by the component manufacturer WO r: ve_T_0790809_L000 end done N accordance with the anent versions of TPI and AFPA design standards. No responstDiliry is assumed for dimensional ecarery. Dimensions ere to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC = 39 WT : 94# T R U S WA L utilized an this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the lop chord TC Live 20.00 psf Li veDu r L=1.2 5 P=1.2 5 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless othervrise TC Snow(Pf) 0.00 psf SnowDu r L=1. 15 P=1. 15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed In any ®SYSTEMSenvironment that will cause the moisture content of the mod to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports' available as output from Truswal software. BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSIrrPI 1', W1CA V. Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION - BC Dean 8.00 psf 0. C. Spaei ng 2— 0— 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onotrfo Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The Amedcan Forest and Paper Association (AFPAI is located at 1111 19th Street, NW. Ste 800. Washington. OC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 Job Name: Shadd I New Residence BRG x -LOC REACT SIZE REQ'D 1 0- 1-12 344 3.50" 1.50" 2 1-11- 0 47 1.50" 1.50" 3 1-11- 4 147 1.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/999 MEM 3-4 (LIVE) LC 27 L= 0.00" D= 0.00" T- 0.00" CRITICAL MEMBER FORCES: (((( 33 2720 COMP OUR TENS1(1. 2i) 0004 DUR 1-2 13 ((2(1.6033/ 14 1.25 0.04 BC COMP. DUR.)/ TENS. DUR. CSI 3-4 -9(1.603/ 26 1.60 0.07 4-0 021.25 / 0 1.60 0.000 TC 2x4 DFL #1 BC 2x4 DFL #1 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearin@ locations. Install interior support (s) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20 sf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. Truss ID: 12y (qty: 2 Designed per ANSI/'r PI 1-20112 This design does not account for long term time dependent loading (creep). Butding Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER, THAT HANGER IS BASED ON 1.5" HANGER NAILS FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY ETHERS). Shim bearings (if needed) for req. support 4.00 3 4 UPLIFT REACrION(S) : Support C&C Wind Non -Wind 1 -118 lb 2 -30 lb 3 -1 lb This truss is designed using the CBC -07 /A CE7-OS Specification Bldg Enclosed Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft Bldg Width 73.00 ft Mean roof height 10.'34 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 4 sgft June 30, 2011 CIVik All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frost Alpine; or preceded by "MX" for TM 20 ga. or "H" for 16 ga. frost Truswal, positioned per Joint Detail Reports. Circled plates and false frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 1 n/1 Rams 268 - Homewood Trup WARNING Read this it to the Erecting Contractor. 11.�J e ail notes on sheet and give a co of g PY 9 B2 W:108 ve WO: Dri ve_T_0790809_L000 WO' 1 -12 R:47 current versions of TPI end AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions and done In accordance with the an U:-30 1-7-10 TC Live 20.00 psf SHIP ublaed on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directty attached, unless otherwise FESS/ SnoWDU r L=1.15 P=1.15 noted. Bracing shorn is for lateral support of components members only to reduce buckling length. This component shall not be placed In any TC Dead 9.00 psf R 147 U:-1 stoat June 30, 2011 CIVik All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 18 ga. frost Alpine; or preceded by "MX" for TM 20 ga. or "H" for 16 ga. frost Truswal, positioned per Joint Detail Reports. Circled plates and false frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 1 n/1 Rams 268 - Homewood Trup WARNING Read this it to the Erecting Contractor. Cust: Mike and Marci Shadd ail notes on sheet and give a co of g PY 9 DIR: Drive_T_0790809_L00005_]00001 This design is for an Individual building component not truss system. It has been based on specifications provided by the component manufacturer ve WO: Dri ve_T_0790809_L000 WO' ® current versions of TPI end AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions and done In accordance with the an #LC = 28 Wi' 11# Dsgn r • are to be verified by the component manufacturer andfor building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 ublaed on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directty attached, unless otherwise TC Snow(Pf) 0.00 psf SnoWDU r L=1.15 P=1.15 noted. Bracing shorn is for lateral support of components members only to reduce buckling length. This component shall not be placed In any TC Dead 9.00 psf Rep Mb r Bird / Comp / Tens ® SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install 'Joint BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. and brace this cuss in accordance with the following standards: and Cutting Detail Reports' available as output from Truswal software, 'ANSlrrPI 1','WrCA 1'- Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Coto. Spgs., CO 80907 (SCSI 1-03) snd'BCSI SUMMARY SHEETS' by W1CA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.91P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreel, NW, Ste 800, Washington, DC 20036. Bldq Code: CBC -07 DFFL RATIO- L/240 TC: L/180 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 0- 1-12 359 3.50" 1.50" BC 2x4 DFL #1 2 3-11- 0 87 1.50" 1.50" Refer to Joint QC Detail Sheets for 3 1-11- 4 173 1.50" 1.50" Cq factors and Rotational Tolerances. BRG REQUIREMENTS shown are based ONLY IRC/IBC truss plate values are based on on the truss material at each bearing testing and approval as required by IBC 1703 MAX DEFLECTION (span) : and ANSI/TPI and are reported in available L/999 MEM 1-2 (LIVE) LC 1 document ESR -1118. L= -0.01" D= 0.00" T= -0.01" Loaded for 10 PSF non -concurrent BCLL. CRITICAL MEMBER FORCES: Loaded for 200 lb non -concurrent moving BCLL TC COMP. DUR. / TENS. WR. CSI 1-2 -31 1.zs / z6 1.2s o.11 Mark all interior bearin44 locations. 2-0 -1 1.25 / 1 1.60 0.00 Install interior supports) before erection. Bc COMP. (DUR.)/ 7ENS. DUR. cSi 20 psf bottom chord live load NOT required 3-4 19(1.60)/ 58 1.60 0.11 on this truss, per IBC/IRC requirements for 4-0 0(1.60)/ 0(1.25 0.00 attics with limited storage. -truss ID: Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIIf FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED THE HANGERS MUST BE RE-EVALUATED (BY GTHERS). PLATING BASED ON GREEN LUMBER VALUES. 2 14 _._..Qty: 2 UPLIFT REACTION(S) Support C&C Wind Non -Wind 1 -126 lb 2 -62 lb 3 -36 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed Yes, Importance Factor = 1.00 Truss Location Not End Zone Hurricane/Ocean Line = No,Exp Category = C Bldg Length = 72.00 ft Bdg Width = 73.00 ft Mean roof height = 10.A4 ft, mph 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area - 4 sqft W:308 W:108 R:359 R:173 U:-126 U:-36 3-11-12 2-0-01-11-12 2-0-01-11-12 2-0-0 0 3 41 B2 W:108 R:87 U:-62 )-1 -18-3-10 SHIP r ,1 J , a.r 1r f -s. I- June 30, 2011 C1V1". All connector plates are Truswal 20 Be. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 Be. frog Alpine; or preceded by "MX" for TWXK 20 Be. or "Al" for 16 ga. frac Truswal, positioned per Joint Detail Reports. Circled plates and false fraae plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood ��A�s ARN/NG Read all notes on this sheet and give a co of it to the Erectin Contractor. g PY 9 Cust: Mike and Marci Shadd This design N for an Individual building component not Was system. It hes been based an specifications provided by the component manufacturer DIR: Drive_T_0790809_L00005_100001 W0: Dri ve_T_0790809_L000 ® and done m accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed lar dimensional accuracy. Dimensions Dsgn r : TM #LC = 30 WT : 15# are to be verified by the component manufacturer sidle, building designer prior to fabrication. The Wilding designer must ascertain that Ne loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the roofer floor sheathing and the bottom dtord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ®SYSTEMS environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install 1.10 and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports' available as output from Truswal software, 8C Live 0.00 psf 1.15 / / 1.10 IM Building Components Group, Inc. 'ANSI/TPI 1', WrCA 1' • Wood Truss Council ofAmerica Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION'- BC Dead 8.00 psf O. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Stu. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 O'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street, NW, Ste 800, Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/180 Job Name: Shadd I New Residence BRG X -LOC REACI' SIZE REQ'D 1 0- 1-12 355 3.50" 1.50" 2 1-11- 0 177 1.50" 1.50" 3 5-11- 4 214 1.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) :. L/971 MEM 3-4 (LIVE) LC 29 L= -0.07" D= -0.02" T= -0.09" CRITICAL MEMBER FORCES: (((( 33 1-20 COMP i(DU1.ZS)� TENS1(1U2i) 0.00 1-2 8 1.60 / 56 1.253 0.27 4840 COM -8(1.66) TENSO(lu2 S) O.39 CII 3-4 8((((1.6033/ 26 1.60 0.39 TC 2x4 DFL #1 BC 2x4 DFL #1 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Install interior supports before erection. PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 0-1 -12 T 03-13 j- Truss 10: J2 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAILf FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Shim bearings (if needed) for req. support 4.00 Qty: 2 UPLIFT REACfION(S) Support C&C Wind Non -Wind 1 -115 lb 2 -15 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed - Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category C Bldg Length = 72.00 ft Bidg Width = 73.00 ft Mean roof height = 10.'34 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 12 sqft 2-0-0 6-0-0 3 4 2 B3 W:108 R:214 U: 1-7-10 THIP 1' N June 30, 2011 CIVIL All connector plates aro Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "IIS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "NX" for TWMX 20 Be. or "N" for 16 Be. frac Truswal, positioned per Joint Detail Reports. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Trru WARNING Read this it to the Erecting Contractor. Cust: Mike and Marci Shadd A p all notes on sheet and give a copy of DIR: D ri ve_T_0790809_L00005_300001 This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer WO: Dri ve_T_0790809_L000 ® and done in accordancewith the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsg n r : TM #LC = 34 WT: 18# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li VeDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the toP chord T R U S WA L Is laterally braced by the roof or floor sheathing and me bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce b -Ir ing length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf P Re Mbr Bnd Com T P � P � Tens and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports available as output from Truswal sofMare, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSlrTPI 1', W1CA 1'- Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaei ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI "3) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) Is located at 583 D'Onohlo Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet, NW, Ste 800,Washington. DC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/180 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D 1 0- 1-12 414 3.50" 1.50" 2 3-11- 0 112 1.50" 1.50" 3 5-11- 4 221 1.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/778 MEM 3-4 (LIVE) LC 29 L= -0.09" D= -0.03" T= -0.12" CRITICAL MEMBER FORCES: 33 2?0 CP1(1U25)� TENSi(DU60) 0000 SI 1-2 30 1.603i)/ 34 1.25 0.29 4--0 BC COMPO(DU251/ TENS ffO.2S) OCO5 3-4 19 1.603/ S7 1.60 0.45 TC 2x4 DFL #1 BC 2x4 DFL #1 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Install interior support(s) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss,per IBC/IRC requirements for attics with limited storage. -truss ID: A Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIL FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Shim bearings (if needed) for req. support 4.00 0-o s -o -o 3 4 63 W:108 R:221 U: _Qty: 2. UPLIFI' REACTION(S) : Support C&C Wind Non -Wind 1 -133 lb 2 -63 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bldg Width 73.00 ft Mean roof height = 10.67 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 12 sqft 110W 2-3-10 SHIP QROFESS/ .6 927 y m June 30, 2011 v? CIV1� CF CAL�F�� An connector rates are Trvswal :o p ga. unless preceded by "M" for Nave 20 ga., "NS" for INS 20 ga., "s" for SS 18 ga. frau Alpine; or preceded by "MX" for TMMX 20 ga. or "N" for 16 ga. froze Trusnal, positioned per Joint Detail Reports. Circled plates and false frawe plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Tru p WARNING Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd i This designis DIR: Drive_T_0790809_L00005_100001 component ea not truss system. It hes been Dosed an specifications provided by the component manufacturer WO � Dri ve_T_0790809_L000 ®(CA and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and1w building designer prior to fabrication. The building designer must ascertain that the loads Ds n r • TM #LC = 34 22# 9 T R U S WA L utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19%end/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSI7TPI 1', WTCA V- Wood Truss Council ofAmerica Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION'- BC Dead 8.00 psf O C. Spaci n9 2- 0- 0 1045 Northpark Dr. Ste. 702, Colo. Spgs., CO 80907 (SCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street, NW, Ste 800, Washington. DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/180 Job Name: Shadd / New Residence Truss ID: J6 Qtv: 2 ERG X -LOC REACT SIZ[ REQ'D 1 0- 1-12 439 3.50" 1.50" 2 5-11- 0 152 1.50" 1.SO" 3 S-11- 4 229 1.50" 1.S0" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/686 MEM 3-4 (LIVE) LC 29 L= -0.10" D= -0.05" T= -0.15" CRITICAL MEMBER FORCES: TC (((( 33 2-0 0C COMP 1(1u25)/ TENS1(1U60) 0000 1-2 47((R II 1.253/ 47 1.2533 0.35 4800 COMPO (DR 11 .65)/ TENSQ(1u25) 0000 3-4 29 1.603/ 88 1.60 0.50 TC 2x4 DFL #1 BC 2x4 DFL #1 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Install interior supports) before erection. PLATING BASED ON GREEN LUMBER VALUES. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. 2-3-12 T a313 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). Shim bearings (if needed) for req. support. 4.00 6-0-0 3 4 UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -153 lb 2 -99 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 11.01 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 12 sqft B2 W:108 R:152 U:-99 2-3-12 2-1 -10 SHIP W:108 R:229 U: A71 connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "NS" for HS 20 ga., "S" for SS 18 ga. from Alpine; or preceded by "NX" for TWNX 20 ga. or "N" for 16 Be. from Trusmal, positioned per Joint Detail Reports. Circled plates and false frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 1 0/15/2009 268 - Homewood Trus Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci $hadd (CA This des Is for an Individual ca design g component not truss system. It has been based an specifications provided by the component manufacturer DIR: Drive_T_0790809_L000OS-100001 ® and done In accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions W0: Drive -T -0790809-L000 are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC = 32 WT: 26# T R U S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes Nat the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or goof sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf $nOWDU r L=1.15 P=1. 1$ ® SYSTEMS noted. Bracing shown Is for lateral support of components members only to reduce buckling length. This component shall not be placed In any environmenl at will cause the moisture content of the wood to exceed 19% and/or cause connector plate cerroWon. Fabricate, handle, install TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens and brace mix truss in accordance with the following standards:' Joint and Cutting Detail Reports available as output from Tmswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 J7W Building Components Group, Inc. 'ANSI/TPI 1', WTCA V. Wood Truss Council ofAmerica Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'SCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onohlo Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I 19th Street, NW. Ste 800, Washington, DC 20036. Bldg Code' CBC-07C:DEFL RATIO' L/240 TL/180 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D TC 2x4 DFL #1 1 0- 1-12 428 3.50" 1.50" BC 2x4 DFL #1 2 6- 0-12 333 1.50" 1.50" Refer to Joint QC Detail Sheets for 3 7-11- 0 21 1.50" 1.50" Cq factors and Rotational Tolerances. 4 5-11- 4 226 1.SO" 1.50" IRC/IBC truss plate values are based on BRG REQUIREMENTS shown are based ONLY testing and approval as required by IBC 1703 on the truss material at each bearing and AN and are reported in available MAX DEFLECTION (span) : document ESR -1118. L/720 MEM 3-4 (LIVE) LC 29 Loaded for 10 PSF non -concurrent BCLL. L= -0.10" D= -0.04" T- -0.14" Loaded for 200 lb non -concurrent moving BCLL CRITICAL MEMBER FoacET Mark all interior bearing locations. TC COMP. DUR. / TENS. DUR. CSI 9 1-2 671.60 / 60 1.25 0.31 Install interior support(s) before erection. 2-0 -46125 / 6 1.25 0.31 20 psf bottom chord live load NOT required 0-0 -111:253/ 1 1.6033 O.oO on this truss, per IBC/IRC requirements for 4B0 COMPO(DI160)/ TEII,(DU1.25) OC 00 attics With limited storage. 3-4 39 1.603/ 119i(((1.60 0.48 Truss ID: J8 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.S" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. 4.00 2 1-11-12 D-0 3 4 OVER 4 SUPPORTS UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -132 lb 2 -215 lb 3 -17 lb -70 lb This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed Yes, Importance Factor - 1.00 Truss Location Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bldg Width = 73.00 ft Mean roof height 11.01 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area - 12 sqft B3 WAOB R:21 T U:-70 24-1133- -10 1 SHIP . . I I SLI, i r r co June 30, 2011 CIV1V. All connector plates are Truswal 10 ga. unless preceded by "H" for Have 20 ga., "HS" for AS 20 ga., "S" for SS 16 ga. frac Alpine; or preceded by "KK" for TM1LC 20 ga. or "H" for 16 Be. frow Truswal, positioned per Joint Detail Reports. Circled plates and false framere plates apositioned as shown above. Shift gable stud plates to amid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Truss Read all notes on this sheet and give a copy of it to the Erecting Contractor. CUs:: Mike and Marci Shadd This design for individual DIR: Dri ve_T_0790809_L00005_J 00001 LOOOO b an building component not mss system. It has been based an specifications provided by the component manufacturer W0: Drive -T -0790809-L000 ® end done in accordance with the current versions of TPI and AFPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions ere to be verified by the component manufacturer andlor building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC = 34 WT: 30# T R U S WA L utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom Mord Is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 SYSTEMS noted. BracingMown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ® environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports' available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSIrrPI 1*,WTCA V- Wood Truss Council of America Standard Design Responsibilities. 13UILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf O.C.Spaeing 2- 0- 0 1445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive. Madison, TRUSPLUS 6.0 VER: T6.5.9P Nsconsin 53719. The American Forest and Paper Association (AFPA) is located at I I I I I gth Street, NW, Ste 800, Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/180 J r Job Name: Shadd I New Residence BRG X -LOC REACT SIZEREQ'O TC 2x4 DFL #1 1 0- 1-12 428 3.50" 1.50" BC 2x4 DFL #1 2 6- 0-12 347 1.50" 1.50" Refer to )oint QC Detail Sheets for 3 9-11- 0 91 1.50" 1.SO" Cq factors and Rotational Tolerances. 4 5-11- 4 226 1.50" 1.50" IRC/IBC truss plate values are based on ERG REQUIREMENTS shown are based ONLY testing and approval as required by IBC 1703 on the truss material at each bearing and AN and are reported in available MAX DEFLECTION (span) : document ESR -1118. L/712 MEM 3-4 (LIVE) LC 29 Loaded for 10 PSF non -concurrent BCLL. L= -0.10" D= -0.04" T- -0.14" Loaded for 200 lb non -concurrent moving BCLL CRITICAL MEMBER FORCES: Mark all interior bearing locations. TC COMP. DUR. / TENS. DUR. CSI 1-z -121 1.60 / 66 1.25 o.3z Install interior support(s) before erection. 2-0 -50 1.25 / z8 1.25 0.32 20 psf bottom chord live load NOT required 0-0 -1 1.25 / 1 1.60 0.00 on this truss, per IBC/IRC requirements for ec COMP. DUR. / TlllljfDit CSI attics with limited storage. a -o 4o 1.25 jr 140 1.25 0.00 4.00 Truss ID: J10 Designed per- ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAIB FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. 2 3-7-12 W:108 R:347 U:-231 2.5X6 0-K13 131 134 W:308 W:108 R:428 R:226 U:-122 6-0-12 U: 9-11-12 3 4 OVER 4 SUPPORTS QtV: 2Y UPLIFT- REACTION(S) : Support C&C Wind Non -Wind 1 -122 lb 2 -231 lb 3 -53 lb -1 lb This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor = 1.00 Truss Location = Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 11.01 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System -Low-rise and Components and Cladding Tributary Area - 12 sqft B3 WA OB R:91 U:-53 43 10 2-3-13 SHIP 1 1 .J to J ` X U) VED All connector plates are Truswal 20 ga. unless preceded by "Y" for Nave 20 ga., "HS" for AS 70 ga., "S" for SS IS ga. frow Alpine; or preceded by "HX" for TWKX 20 ga. or "H" for 16 Be. from Trusmal. positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Trup Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This designis lar an individual building component not truss tem. It has been based on specifications provided D the co a mp s7a p y mponerdmuracy.tDim DIR : D r l Ve_T_0790809_L00005_J 00001 W0: Drive_T_0790809_L000 ® and done H accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC = 34 WT: 33# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf Li veDu r L=1.25 P=1.25 utilized on this design meet or exceed the loading Imposed by the local building code and the particular application. The design assumes that the top chord T R U S WA L is laterally braced by the rosier floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 9.00 psf Rep Mbr Bnd / Comp / Tens ® SYSTEMS environment ..twillcause lhamoisture content at ha -ad toexceed I..and/orceuseconnectorplatecorrosion. Fabricate, handle, Install and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. 'ANSI/TPI 1', WTCA V- Wood Truss Council of America Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION- BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Slogs., CO 80907 (BCSI "3) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss plate Institute (TPI) is located at 583 D'Onokio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated atIIII I 9th Street, NW, Ste 800. Washington, DC 20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC- L/180 Job Name: Shadd / New Residence BRG X -LOC REACT SIZE REQ'D 1 0- 1-12 425 3.50" 1.50" 2 6- 0-12 414 1.50" 1.50" 3 11-11- 0 144 1.50" 1.50" 4 5-11- 4 225 1.50" 1.50" BRG REQUIREMENTS shown are based ONLY on the truss material at each bearing MAX DEFLECTION (span) : L/706 MEM 3-4 (LIVE) LC 29 L- -0.10" D- -0.04" T= -0.14" CRITICAL MEMBER FORCES: Tc COMPDUR. / TENS. DUR. CSI 1-2 Si -15 1.60 / 641.25 0.44 2-0 -66 1.25 / 441.25 0.43 0-0 -1 1.25 / 111.601 ))) 0.00 Bc 3:4 COMPO(DU1.Z S)� TEN50(1U25) 0.00 3-4 59(((((ISI 1.6033/ 174 1.60 0.48 TC 2x4 DFL #1 BC 2x4 DFL #1 Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and ANSI/TPI and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Mark all interior bearing locations. Install interior support(s) before erection. 20 psf bottom chord live load NOT required on this truss,per IBC/IRC requirements for attics with limited storage. 4.00 12 2.5X6 z 0-3-13 61 W:308 R:425 U:-107 Truss 10: J12 Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF MULTIPLE LOAD CASES. IF THIS TRUSS IS CARRIED IN A HANGER THAT HANGER IS BASED ON 1.5" HANGER NAILf FOR 1 -PLY AND 3" HANGER NAILS FOR MULTI -PLY CARRYING MEMBERS. IF 2.5" GUN NAILS ARE USED, THE HANGERS MUST BE RE-EVALUATED (BY OTHERS). PLATING BASED ON GREEN LUMBER VALUES. UPLIFT REACTION(S) : Support C&C Wind Non -Wind 1 -107 lb 2 -276 lb 3 -96 lb This truss is designed using the CBC -07/ ASCE7-05 Specification Bldg Enclosed - Yes, Importance Factor = 1.00 Truss Location - Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bidg Width = 73.00 ft Mean roof height = 11.01 ft, mph 85 ASCE7 II Standard Occupancy, Dead Load - 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area - 12 sqft 83 W:108 R:144 U:-96 WAN 4-1 -10 R:414 SHIP U:-276 2-3-13 1 B4 W:108 R:225 U: 11-11-12 2.0-0 s -o -o 5-11-12 3 4 OVER 4 SUPPORTS All connector plates are Truswal 20 ga. unless preceded by "Ir for Wave 20 ga., "HS" for HS 20 ga., "S" for SS 16 Be. free Alpine; or preceded by "HX" for TWWX 20 Be. or "H" for 16 ga. froe Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frase plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Trrur Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marti Shadd This design is for an individual building component not truss system. It has been based on specifications provided by the component manufacturer DIR: D ri ve_T_0790809_L00005_300001 W0: Drive -T -0790809-L000 ® and done in accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions Dsgn r : TM #LC = 34 WT: 37# are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads TC Live 20.00 psf L i ve Du r L=1.25 P=1.25 ubRted on this design meet or exceed the loading imposed by the local building code and the panimlar application. The design assumes Nat the top chord T R U S WA L is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shall not be placed in any TC Dead 9.00 psf Rep Mb r Bnd / Comp / Tens ®SYSTEMSenvironment that will cause the moisture content of the mod to exceed 19% andfor cause connector plate corrosion. Fabricate, handle, install BC and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Report available as output from Truswal software, Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. ,ANSI/TPI 1'. WTCA V. Wood Truss Council of America Standard Design Responsibilities,'BUILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf O. C. Spaci ng 2- 0- 0 4445 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1-03) and'SCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet. NW. Ste 800.Washington, OC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/180 w Job Name: Shadd / New Residence BRG X -LOC REACT SIZEREQ'D 1 0- 1-12 436 3.50" 1.50" 2 3- 8-12 309 HGR 1.50" BRGREQUIREMENTS shown are based ONLY on the truss material at each bearing BRG HANGER/CLIP NOTE 2 U24 16d SupportConnection(s)/Hanger(s) are not designed for horizontal loads. SEE SIMPSON CATALOG FOR ADDITIONAL INSTALLATION NOTES MAX DEFLECTION (span) : L/999 MEM 3-4 (LIVE) LC 30 L= -0.02" D- -0.01" T= -0.03" EX.WB DEF CRITERIA:L/120 IN MEM 4- 2; T- 0.00" CRITICAL MEMB(ER RfiFO)RCES: ( ) 1-2 C -66((1U60))/ TEN47((/U25)) 0.23 T8CCB SS. 3-4 COMP.fflt TEN74 ((/U60)) 0.31 2W4 C -17 (D.2 S)� TEN16(1U60) 0.03 TC 2x4 DFL #1 BC 2x4 DFL #1 WEB 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL Permanent bracing .s required to prevent rotation /toppling. Refer to BCSI and ANSI/TPI 1. 20 psf bottom chord live load NOT required on this truss, per IBC/IRC requirements for attics with limited storage. Truss ID: M4 _ Qty: 6 Designed per ANSI/TPI 1-2002 Required bearing widths and bearing areas This design does not account for long term apply when truss not supported in a hanger. timeggdependent loading (creep). Building UPLIFT REACTIONS) THIt ISS0 SIGNner mIStTHECCOMPOSITEtRESULT OF ount orSupp1 ort C8121i�dh Non -Wind RRIED IN A HANGER THAT 1.5" HANGER NAIB FOR R NAILS FOR MULTI -PLY IF 2.5" GUN NAILS ARE MUST BE RE-EVALUATED PLATING BASED ON GREEN LUMBER VALUES. End verticals are designed for axial loads only unless noted otherwise. Extensions above or below the truss profile (if any) have been designed for loads indicated only. Horizontal loads applied at the end of the extensions have not been considered unless shown. A drop -leg to an otherwise unsupported wall may create a hinge effect that requires additional design consideration (by others). 4.00 This truss is designed using the CBC -07 / ASCE7-OS Specification Bldg Enclosed = Yes, Importance Factor - 1.00 Truss Location Not End Zone Hurricane/Ocean Line = No Exp Category = C Bldg Length = 72.00 ft, Bldg Width = 73.00 ft Mean roof height 10.65 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 12 sgft Vertical members exposed to wind: 4- 2 ----------LOAD CASE #1 DESIGN LOADS ---------------- Dir L.Plf L.LOc R.Plf R.Loc LL/TL TC Vert 74.00 - 2- 0- 0 74.00 0- 0- 0 0.54 TC Vert 58.00 0- 0- 0 58.00 1- 0- 0 0.69 TC Vert 98.00 1- 0- 0 98.00 3-10- 8 0.41 TC Vert 74.00 3-10- 8 74.00 4- 0- 0 0.54 BC Vert 16.00 0- 0- 0 16.00 3-10- 8 0.00 B1 B2 W:308 U24 R:436 W:308 U:-121 R:309 and done in accordance with the anent versions of TPI and AFPA design standards. No respona3iGty is assumed Iw dimensional accuracy. Dimension responsibility U:-82 0-0 3-10-8 0 8 3 4 11L.w - All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "Hs" for HS 20 ga., "S" for SS 18 ga. froar Alpine; or preceded by "HX" for TM11X 20 ga. or "Al" for 16 ga. frog Truswa7, positioned per Joint Detail Reports. Circled plates and false frase plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 10/15/2009 268 - Homewood Trus WARNINGRead all notes on this sheet and give a copy of it to the Erecting Contractor. Dust: Mike and Marci shads (CA This design Is for an co gn g component not buss system. It has been based on provided by the component manufacturer DIR: Drive_T_0790809_L00005_J00001 ® and done in accordance with the anent versions of TPI and AFPA design standards. No respona3iGty is assumed Iw dimensional accuracy. Dimension responsibility WO' Dri ve_T_0790809_L000 ' are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC = 33 WT: 21# T R U S WA L uol¢ed on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord Live TC Live 20.00 psf L i ve Du r L=1.2 S P=1.2 5 Is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material direc9y attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 ® SYSTEMS noted. Bradng shovm is for lateral support or components members only to reduce budding length. This component shall not be placed in any environment that will cause the moisture content of the wood to exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install TC Dead 9.00 psf Rep Mb r Brill / Comp / Tens and brace this truss in accordance with the following standards:'Joint and Cutting Detail Reports available as output from Ttuswal software, BC Live 0.00 psf 1.00 / 1.00 / 1.00 /i611P Building Components Group, Inc. 'ANSI/TPI 1', W1CA V. Wood Truss Council of America Standard Design Responsibilities, BUILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf 0. C. Spaci ng 2- 0- 0 4645 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (SCSI 1.03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onokio Drive, Madison, TRUSPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association AFPA) is located at I I I I I 9th Street, NW, Ste 800, Washington. OC 20036. Bldg Code' CBC -07 DEFL RATIO• L/240 TC L1240 Job Name: Shadd / New Residence CRITICAL MEMBER FORCES: TC 2X4 DFL "1 BC 2x4 DFL #1 GBL BILK 2x4 DFL STANDARD Refer to Joint QC Detail Sheets for Cq factors and Rotational Tolerances. IRC/IBC truss plate values are based on testing and approval as required by IBC 1703 and AN and are reported in available document ESR -1118. Loaded for 10 PSF non -concurrent BCLL. Loaded for 200 lb non -concurrent moving BCLL May use adequate staples for gable blocks. BUILDING DESIGNER MUST VERIFY CABLE LOADS AND EAVE LOADS, IF APPLICABLE. THIS TRUSS IS DESIGNED TO SUPPORT THE LOADS SPECIFIED BASED ON THE O.C. SPACING AND ANY ADDITIONAL LOADS SHOWN. [. gable bracing required @ 61" intervals, if expPosed to wind load applied to face. See ITWBCG's Cable Bracing Details. truss ID: MG Designed per ANSI/TPI 1-2002 This design does not account for long term time dependent loading (creep). Building Designer must account for this. THIS DESIGN IS THE COMPOSITE RESULT OF PLATING BASED ON GREEN LUMBER VALUES. 20 ppsf bottom chord live load NOT required on tFtis truss, per IBC/IRC requirements for attics with limited storage. j 44 00 1-r10 1-3-13 z.5X I 2- -B 10-913 1 j SHIP OVER CONTINUOUS SUPPORT 3 TYPICAL PLATE: 1.5X3 OVER CONTINUOUS SUPPORT This truss is designed using the CBC -07 / ASCE7-05 Specification Bldg Enclosed Yes, Importance Factor = 1.00 Truss Location Not End Zone Hurricane/Ocean Line = No,Exp Category = C Bldg Length = 72.00 ft, Bdg Width = 73.00 ft Mean roof height = 10.51 ft, mph = 85 ASCE7 II Standard Occupancy, Dead Load = 10.2 psf Designed as Main Wind Force Resisting System - Low-rise and Components and Cladding Tributary Area = 6 sqft 'L J1 Ir N June 30, 2011 civic All connector plates are Truswal 20 ga. unless preceded by "W" for Wave 20 ga., "16" for HS 20 ga., "S" for SS 18 ga. froom Alpine; or preceded by "WX" for TWWX 20 ga. or "N" for 16 ga. from Truswal, positioned per Joint Detail Reports. Circled plates and false 10/15/2009 frame plates are positioned as shown above. Shift gable stud plates to avoid overlap with structural plates (or staple). 268 - Homewood Tr,�uys Read all notes on this sheet and give a copy of it to the Erecting Contractor. Cust: Mike and Marci Shadd This is for individual DIR: Dri ve_T_0790809_00005_] 00001 LO000 design an building component not buss system. It has been based on specifications provided by the component manufacturer W0: Drive -T -0790809-L000 ® and done In accordance with the anent versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions are to be verified by the component manufacturer and/or building designer prior to fabrication. The building designer must ascertain that the loads Dsgn r : TM #LC = 29 WT: 17# T R U S WA L utilized on this design meet or exceed the loading imposed by the local building code and the particular application. The design assumes that the top chord TC Live 20.00 psf Li veDu r L=1.25 P=1.25 is laterally braced by the roof or floor sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise TC Snow(Pf) 0.00 psf SnowDu r L=1.15 P=1.15 SYSTEMS noted. Bracing shown is for lateral support of components members only to reduce buckling length. This component shag not be placed in any TC Dead 9.00 psf Rep Mbr End / Comp / Tens ® environment the, will cause the moisture content of the vwoodtoexceed 19%and/or cause connector plateconosion. Fabricate, handle, Install and brace this truss in accordance with the following standards: 'Joint and Cutting Detail Reports available as output from Truswal software, BC Live 0.00 psf 1.15 / 1.10 / 1.10 IM Building Components Group, Inc. •ANSUTPI 1', WTCA V- Wood Truss Council of America Standard Design Responsibilities, 'BUILDING COMPONENT SAFETY INFORMATION - BC Dead 8.00 psf 0. C. Spaci ng 2— 0— 0 4405 Northpark Dr. Ste. 102, Colo. Spgs., CO 80907 (BCSI 1-03) and'BCSI SUMMARY SHEETS' by WTCA and TPI. The Truss Plate Institute (TPI) is located at 583 D'Onofrio Drive, Madison, TRU SPLUS 6.0 VER: T6.5.9P Wisconsin 53719. The American Forest and Paper Association (AFPA)islocated at111119thStreet. NW, Ste 800,Washington, DC20036. Bldg Code: CBC -07 DEFL RATIO: L/240 TC: L/240 AA -P �� ,sti;�leY COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS y� 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT PERMIT NO. ASSESSOR PARCEL NUMBER ZONING ZONING BUILDING PERMIT OWNERj //'ij' I �I TELEPHONE SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS w _ y y. / � % f� I f 1 C � CONTRACTOR'S NAME \!yp', y ( i, TELEPHONE � 1 CONTRACTOR'S MAILING ADDRESS I Fireplace CONSTRUCTION LENDER UNKNOWN LENDER'S MAILING ADDRESS i Total Valuation Is Filing Fee Permit Fee $ 10.00 $ ARCHITECT OR ENGINEER LICENSE No. ARCHITECT OR ENGINEER'S MAILING ADDRESS Plan Checking Fee Penalty Permit fee $ $ $ BUILDING ADDRESS PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 01 r 1'4" / Water piping LOT NO. SUBDIVISION NAME PARCEL• MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF D."'Duplex❑ Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New❑ Addition❑ Remodel❑ Utilities❑ Installation❑ Other Er", Describe work: Permit Fee $ Contractor ELECTRICAL PERMIT FilingFee 10.00 Main service 001 OR LE 100 AMP ORSLESS /400 /0-0o Main service EA. ADD'L 100 AMP 1 2.50 � NEW CONST. (DWELLING OCC UP.py) OR ADDNS. \ ACC. BLDGS. 22 sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ❑NON-RESID. I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and m license is in full force and effect. Y License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTIR MULTI -OUTLET 2,50 ea NON-RESID BRANCH CIRC ITS NEW CONSTR. POWER APPARATUS 6\ %SINGLE OUTLET CIR. 1 @254 Ex. Occup OUTLETS OR FIXTURES BAL@1 EX. Occup. (OUT LETS IXED P(RESID )REA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring /0 -.O� Permit Fee $ Contractor MECHANICAL PERMIT FiIirig Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject % to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee S Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue •the granting of this permit. against said County in consequenceyl� (% �_'„,� J„� X ! hP-4 W. ��� i�S-..N Date Signature of Applicant — Owner Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OCCUP. GROUP I TYPE OF CONST, PARCEL PD HD I ISSUE {,�/ This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which w r DIRECTOR OF PUBLIC BY � � �"- PERMIT EXPfRES Date the applicable provi- resolutions to do fees have been paid. WORKS �1 Date,l�' Receipt No. �/ 9X � WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE O' DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile — Phone: 534-4541 Skyway and Elliott Road, Paradise— Phone: 872-2961, Ext. 57 CORRECTION NOTICE 4 BUILDINGC/O/R PROPERTY ADDRESS A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this moffnr — n—A nAAifi—I a-1—finn Man— rnnfnrf fhic nffira immaAinfalu r � r~ j z F-4 _ Inspector ; fA ` =' Date S 1 COUNTY OF BUT ITMENT OF PUBLIC WORKS Orov 7 County Center Drive - ;Califo"rnia 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT PERMIT NO. .ifA;)l ASSESSOR PARJEL NUM ZONING .— ,. BUILDING PERMIT OWNERA_J , TEL EP QX t W IRA 2(� SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING DRESS 1 CONTRACT R•S NAMIEG �+ 0 TELEPHO E CONTRACTOR'S MAILING ADDRESS - Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee ,$ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING ADD R SS rS a PLUMBING PERMIT Filing Fee 10.00 — Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping. LOT NO. SUBDIVISION NAME PARCE MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF L!J Duplex❑ Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Uti lities ❑ Installation❑ Other Describe work: Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service V OR LE 10000 AMP ORSLESS /000 Main service EA_ ADD -L 100 AMP 2.50 NEW CONST.( DWELLING OCCUP.0j) OR ACDNS. ACC. BLDGS. ., 20 Sq it // CONTRACTORS LICENSE LAWNEW I declare under penalty of perjury (check one): ElI am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and m license is in full force and effect. Y License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason CONSTR U 1 -OUTLET 2.SOea NON-RESID BRANCH CIRC ITS NEW CONSTR POWER APPARATUS S NON.RESID. (SINGLE OUTLET CIR.' s0025Q Ex. Occup OUTLETS OR FIXTURES BAL@1 Ex. Occup.(our ETSP(RESID.)R EAJ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 0 j •• 0 a Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that 1 have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agains id unty in con q ce o the granting of this permit. %�N7 - n Date -� Signature of Applicant — Owner C tractor ❑ Agent ❑ An OSHA permit is required for ex ovations over 5'0" deep and demolition or construct- ion -of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OccuP. GROUP I TYPE OF CONST. [-IPARCELI PO ND 5su� 1 This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIR OR, BLIC BY PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date ®� Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT WBUTTE '� ` COUNTY September 9, 2009 SEP 10 2009 IDEW L01)MENT SERVICES Chris Thomas' #7 County Center Drive Oroville, CA 95965 Dear Chris, As per our conversation this letter is to clarify our intentions regarding our residence at 247 Higgins Ave, Gridley, CA 95948. Once we have completed construction of the new 4 bedroom home we will be removing the older 2 bedroom home leaving only one, single family dwelling on the property. ; Thank you, Mike Shadd Owner z ?0 6)dC,_ ��C9`Dm .o.T. Roof 1 irl@ 3D Layo MM p T L �00000 system gi-lacdd . / New Res z dans a MiI--e and Marci S1-1adcl 2 4 7 Hiirns Ave Grii c11 ay , Ca SALES REP: TM DUE DATE: 08/26/09 D S GN R/ C H KR : 'EM / CM i TC Live 20.00 psf TC ,Dead 9.00 psf BLive 0.00 psf Sc Dead 8.00 psf Total 37-00 psf WO#: 0790809 SCALE: 1"=10' 0" Date: 10/14/2009 11:2. DurFac-Lbr 1-25 DurFac-Plt _ 1.25 O -C- Spacing: 2 Design Spec: #Tr/#Cfg.: 78 / 36