HomeMy WebLinkAbout027-070-021BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:,(530) 538-7636 (OROVILLE).(530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAX#: (530)538-2140 WEBSITE: www.buttecounty.net\dds PERMIT NO. BP041831 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 06/23/2004 APN• 027-070-021-000 the Business and Professions Code, and my license is in full force and ' effect. License Class: License Number: Site Address: 2460 MAPLE AVE PAL Date: Contractor. Map Index: + Description: COVER OVER EX DECK(1242) OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that l am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior Owner: SORIA ERASMO R & VERONICA to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9 commencing with Section 2110 WILLIAMS AVE 7000) of Division 3 of the Business and Professions Code) or that he or PALERMO, CA she is exempt therefrom and the basis for the alleged exemption. Any 95968 violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does Applicant: SORIA ERASMO R & VERONICA such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one 2110 WILLIAMS AVE year of completion, the owner -builder will have the burden of PALERMO, CA proving that he or she did not build or improve for the purpose of sale.). 95968 ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). Contractor: ❑ 1 am Exempt under Article 3 of the Business and Professions Code Date: Owner: WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for License #: workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of -Architect: the work for which this permit is issued. My workers' compensation Engineer: g insurance carrier and policy number are: Carrier: Total Square Ft: 1242 S. F. nn�� Policy #:_ (e/✓�y f ��� m I certify that in the performance of the work for which this permit is Valuation: $19 872.00 issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, Census Code: and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY This permit is hereby issued under the applicable provisions of the Butte County Code 2nd/or I hereby affirm that there is a construction lending agency for the Reso!jory to dQ,work indica d above,r whi fees have been paid. performance of the work for which this permit is issued (Sec 3097 Civ.) Name: - Date: - PERMIT EXPIRES ON: ate Address: ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte County to enter upon the above mentioned property for inspection purposes. Print Name: (% C,— Signature: Date: ❑ Owner ❑ Contractor ❑ Agent for Owner ❑ Agent for Contractor OB. -I OWNER BUILDER IlJFORAIATION Dear Properly Owner. An application for a building permit has been submitted in you name listingyourself as the bunlder of property improvements specified. _ . For your protection, you should be aware that as owner-bWIder" you are the responsible party ofrecord on such a Penuk Building Penmits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other furan yonrsel You may Protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on, all permits for which they apply if you plan to do you own work, with the exception of various trades that you plan to subcOutact; you should be aware of the following informa]ion for your benefit and protection: a If you employ or othMwIm engage any Persons other than your immediate famuly, and the work (including matnials and other costs) is S3oo or more for the entire Project; and such persons are not licensed as contract -,ors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Go vemmeats as as employer and you are subject to several obligations including state and federal income tax wiibholdmg, federal social security taxes, wow ComPen-Mon mnxance, disabibly ins rM= costs, and unemployment compensation, coniribulions. Theremay be financial risks for you if you do not any out these obligations, and these t isles are with respect to wow's comipensatkm hwmance. SP Y serious ♦ For more specific information about your obligations under Federal Law, contract the internal Revenue Service (and, if you wish, the U.S. Small Business AdmkbftzdM). For more specific fi&nnation about your obligations under State Law, contact the Departmem of Benefit Payments and the Division of industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed Persons Professing to be contractors is to secare an "owner builder" building Pew, erroneously implying that the property owner is Providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are p T` Imfostion about licensed factors may be. obtained b er�.mg their own work se Boar personally. community or at 1020 Id Street; S Y �e m State Lncemse Board in your PIease l� � moo' �' 95814.. .. COMP "Owner Builder Verification" on the reverse side of this form so flint we can confirm that you are aware of these matters. The building pew wM not be issued uml the verification is returned, M'i 1 aZ�d na, C.B.O. ingInspection NOT M T ytis Owner-Bur7derlrzfornadaR is requfred by Seddon 14830 of the Cafcfornia Health and Safety Code O.B.- I OWNER-BUUIIIDER VERIFICATION Attention Property Owner: An "owner-buildee' building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. I. I personally plan to provide the major labor'and materials. -for construction of the proposed property improvement: YES NO ❑ I HAVE.[- HAVE NOT ❑ signed an application for a building permit for the proposed work. I have contracted with the following person (firm) to provide the proposed construction: NAME: ADDRESS: may: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work NAME: ADDRESS: PHONE: CONTRACTOR'S LICENSE NO. S. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIG PROPLR'TYYOWER N_ DATE:_ 7 NOTA: This Owner -Builder VerVi ation is required by Section 19831 and 19832 of the California Health and Safety Code. This veykation mast be completed and returned to our office before we are permitted to issue the permit OVER KBI 3721 FEATHER RIVER BLVD, MARYSVILLE, CA 95901 530-740-7906 FAX 530-742-7908' ROOF TRUSS ENGINEERING DATE: 07-26-2004 WET TAMP SORIA 1r3) BUTTE COUNT'S BUILpING DIVISION APPROVED ® " Mitek Industries; -Inc. 7777 GREENBACK LANE - SUITE 109 ` CITRUS HEIGHTS CA 95610. M iTe k USA FAX (916) 676.1,909'• • TELEPHONE (916) 676 1900 ' Re:. RAUL1 ; The. truss drawing(s) referenced below have. been prepared by. MiTek Industries, Inc. under my; direct supervision based on the. parameters provided by KBI Norcal Truss. ` Pages or sheets covered -by this. seal:. R12989968..thru R12989969 My license, renewal date. for. the. state, of California is June. 30, 2005:. . co vo: ,180 Z EX AllL July 23,2004 Anderson, Bob ' The. seal on these 8rawings,indicate. acceptance of professional engineering responsibility. solely for the, truss components shown.. The. suitability and use of this component for any particular. building is the. • responsibility of the building designer, per. ANSI/TPI-2002 Chapter 2. 4 26-0-0 KBI TRUSS 3721 FEATHER RIVER BLVD SORIA MARYSVILLE, CA 95901 740-7906 742-7908 FAX GR k Job Truss Truss Type Qty Ply R12989968 RAUL1 Al COMMON 2 1 (optional) Kt31 Norcal, marysviije, Ga. 909u7 4.Zu1 AK1 S NOV lb zuuu mi lex Inaustnes, Inc. Fn JUl L3 1b:3b:U4 2004. Nage 1 . -2-0-0 13-0-0 26-0-0 28-0-0 2-0-0 • 13-0-0 13-0-0 ' 2-0-0 r Scale = 1:48.6 F 0 5x6 I I 3.25F1-2 10 3X4. = 34 33 3Z 31 3u 29 26 21 Zb , Zb 24 23 22 21 20 -3X4 5x5 = ,26-0-0 LOADING (psf) SPACING 2-M CSI DEFL in ' (loc) I/deft PLATES GRIP TCLL 20.0 Plates Increase 1.25 TC 0.13 Vert(LL) n/a n/a M1120 220/195 TCDL 14.0 Lumber Increase 1.25 BC 0.09 Vert(TL) 0.01 _ 1 >999 BCLL 0.0 Rep Stress Incr YES WB 0.02 Horz(TL) 0.00 18 n/a BCDL 7.0 Code UBC97/ANSI95 (Matrix) 1st LC LL Min I/def1=.240 Weight:. 141. Ib LUMBER BRACING TOP. CHORD 2 X 6, DF. No.2-G TOP. CHORD Sheathed or 6-M, oc purlins. BOT. CHORD 2 X 4. DF. Std -G BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4. DF. Std -G REACTIONS (Ib/size) 2=310/26-M, 27=106/26-M, 18=310/26-", 28=110/26-", 29=109/26-0-0, 30=109/26-", 31=109/26-", r 32=114/26-", 33=71/26-", 34=217/26-". 26=110/26-0-0, 25=109/26-0-0, 24=109/26-", 23=109/26-", r 22=114/26-", 21 =71 /26-", 20=217/26-" Max Horz 2=31 (load case 2) Max Uplift 2=-101(load case 2),.18=-106(load case 3), 29=-7(load case 2), 30=-5(load case 2), 31=-5(load case 2), 33=-32(load case 2), 25=-7(load case 3), 24=-5(load case 3), 23=5(load case 3), 21=-32(load case 3) Max Grav 2=310(load case 1), 27=106(load case 1), 18=310(load case 1), 28=110(load case 1), 29=111(load case 5), 30=109(load case 1), 31=109(load case 1), 32=114(load case 5), 33=71(load case 5), 34=217(load case 5), 26=110(load case 1), 25=111(load case 6), 24=109(load case 1), 23=109(load case 1), 22=114(load case 6), 21=71(load case 6), 20=217(load case 6) FORCES (lb) -.S Load Case Only IJT7�E e,S TOP CHORD 1-2=29,2-3=45,3-4=-23,4-5= - 9, 5-6=8,6-7=8,7-8=8, 8-9=8, 9-10=8, 10-11=-16, 11-12=-16, 12-13=-16, 13-14 r CtJJ 14-15=-15,15-16=-15.16-17=-23,17-18=-45,18-19=29 �+� sd BOT.CHORD 2^34^4, 33-34=4, 3233=4, 31-32'4, 30-31=4, 29-30=4, 28-29=4, 27-28=4, 26-27=4, 25-26=4, 24-25=4, 23-24=4, ����a nit BQ Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury � 3j4' 'Center plate on joint unless dimensions indicate otherwise. Dimensions are in inches. Apply 1. Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property securely seat. owner and all other interested parties. J2 J3 J4 2. Cut members to bear tightly against each .. TOP CHORDS other. /$ C2 C3 J5 3. Place plates on each face of truss at each o C, 3 joint and embed fully. Avoid knots and wane O , 3 at joint locations. O U �y U U 4. Unless otherwise noted, locate chord splices O at 1/4 panel length (± 6" from adjacent joint.) 'For 4 x 2 orientation, locate Cs BOTTOM CHORDS C6 O 5. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. plates 1/8" from outside edge J 1 J8 J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator. General FARTHEST TO THE LEFT. practice is to camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT 8. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. 4 4 The first dimension is the width 9. Lumber shall be of the species and size, and x perpendicular to slots. Second in all respects, equal to or better than the dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins ICBO 3907, 4922 provided at spacing shown on design. LATERAL BRACING SBCCI 9667,9432A 11. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, Indicates location of required WISC/DILHR 960022-W, 970036-N Y unless otherwise noted. continuous lateral bracing. NER 561 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints at sal 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. k 4;a 1141 .. engineer. III iN MiTek® . 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 © 1993 MiTek® Holdings, Inc. Job Truss � Truss Type Qty Ply ' 8) Provide mechanical connection (by, others) of truss to bearing plate capable of withstanding 101:Ib uplift at joint 2, 106 Ib uplift at joint 18, 7.1b uplift at joint 29, 5 Ib uplift at joint 30, 5 Ib uplift at joint 31, 32 Ib uplift at joint 33, 7. Ib uplift at joint 25, 5 Ib uplift at joint 24, 5 Ib`uplift at joint 23 and 32 Ib uplift at joint 21. 9) This truss has been designed with ANSI/TPI 1-1995 criteria. , R12989968 RAULI Al COMMON 2 1 Uniform Loads (plf) 'Vert: 2-18=-14.0, 1-10=-68.0; 10-19=-68.0 f 2) Wind Left: Lumber Increase=1.33, Plate Increase=1.33 " (optional) msl rvorcai, marysvme, e_,a. aoau i 4.tuf .,)K) s lvov 1o,duuu ml1 eK lnoustnes, Inc. rn .furs 15:so:u4 zuu4 rage z NOTES 7) A plate rating reduction of 20% has been applied for the green lumber. members. ' 'Y ' 8) Provide mechanical connection (by, others) of truss to bearing plate capable of withstanding 101:Ib uplift at joint 2, 106 Ib uplift at joint 18, 7.1b uplift at joint 29, 5 Ib uplift at joint 30, 5 Ib uplift at joint 31, 32 Ib uplift at joint 33, 7. Ib uplift at joint 25, 5 Ib uplift at joint 24, 5 Ib`uplift at joint 23 and 32 Ib uplift at joint 21. 9) This truss has been designed with ANSI/TPI 1-1995 criteria. , LOAD, CASE(S) - t 1) Regular. Lumber.-Increase=1.25, Plate Increase=1.25 t , Uniform Loads (plf) 'Vert: 2-18=-14.0, 1-10=-68.0; 10-19=-68.0 f 2) Wind Left: Lumber Increase=1.33, Plate Increase=1.33 " Uniform Loads (plf) ' Vert:.2-18=-14.0, 1-2=37.5, 2-10=14.2, 10-18=6.6,18-19=30.0 Horz:.1-2=-65.5, 2-10=-42.2,16-'18=34.6,18-19=58.0 ' 3) Wind Right: Lumber Increase= 1.33, Plate Increase=1.33 + . Uniform Loads (plf) „ Vert:. 2-18=714.0, 1-2=30.0, 2-10=6.6, 10-18=14.2, 18-19=37.5 " Horz: 1-2=-58.0, 2-10=-34.6•,10-18=42.2, 18-19=65.5 + 4) 1st Wind Parallel:. Lumber Increase= 1.33, Plate Increase= 1 .33 Uniform Loads (plf) .+ _ Vert:.2-18=-14.0, 1-2=30.0, 2-10=6.6,10-18=6.6,18-19=30.0 t Horz 1-2=-58.0, 2-10=34.6, 10-18=34.6, 18-19=58.0 5) 1st unbalanced Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plo Vert: 2-18=-14.0, 1-10=-68.0,10-19=-28.0 6) 2nd unbalanced Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform loads (pif) ° t _. Vert: 2-18=-14.0, 1-10=-28.0,10-19=-68.0 Y: N ' ®.WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an in building component to be installed and loaded vertically. Applicability of design parameters and proper Incorporation of _ - component is responsibility of building designer — not truss designer. Bracing shown Is for lateral support of individual - t web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erectoK Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection, and bracing, consult OST -88 Quality Standard, DSB- 89 Bracing Specification, and HIS -91 Handling Installation and Bracing Recommendation available from Truse ' Plate Institute, 583 D'Onofrio Drive, Madison, wi 6719 - MiTek Industries, Inc. Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury � 3/4' 'Center plate on joint unless" dimensions indicate otherwise. Dimensions are in inches. Apply 1. Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property securely seat. owner and all other interested parties. J2 J3 J4 2. Cut members to bear tightly against each .. TOP CHORDS other. /$ �/$ ♦ ~ C2 C3 J5 3. Place plates on each face of truss at each c, 3 joint and embed fully. Avoid knots and wane 0 ; O at joint locations. V v+ U �h U4. Unless otherwise noted, locate chord splices Oat 1A panel length (± 6" from adjacent joint.) ' For 4 x 2 orientation, locate C8 BOTTOM CHORDS C6 O 5. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. plates 1/8" from outside edge 11 J8 J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is riot applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator. General FARTHEST TO THE LEFT. practice is to camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT 8. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. The first dimension is the width 4 4 9. Lumber shall be of the species and size, and x perpendicular to slots. Second in all respects, equal to or better than the dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins ICBO 3907, 4922 provided at spacing shown on design. LATERAL BRACING SBCCI 9667, 9432A 11. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, Indicates location of required WISC/DILHR 960022-W, 97.0036-N unless otherwise noted. continuous lateral bracing. NER 561 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints at 1.%�_ 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. engineer. FI li MiTek® 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 © 1993 MiTek® Holdings, Inc. A Job Truss Truss Type City Ply + „ dead load.and 7.0. psf bottom chord dead load, 100. mi from hurricane oceanline, on an occupancy, category I, condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE 7-93 per. UBC97/ANSI95 If end verticals or cantilevers exist, they are exposed to wind... If porches exist, they are not'exposed to wind.The lumber. DOL increase is 1.33, and the plate grip, increase is R12989969 RAUL1 A2 '. COMMON 24 1 joint 6. 5) This truss has been designed with ANSI/TPI 1-1995 criteria. pF ES$/ OQR ql�� • C. AN� LOAD. CASE(S) (optional) K01 tvorcal, nnarysvuie, t a. aoaui 4.zu1 arcs s rvov ID zuvu ml1 eK Inausines, Inc. rn im zi. io=:i5 zuua. rage 1, -2-6-0 7-0-0 13-0-0 19-0-0 26-0-0 %7 28-0-0 2-00 7-0-0 6-0-0 6-0-0 7-0-0 o -o r _ ' Scale =.1:48.6 5x5. _ 3.25 12 4 7-0-0 • 13-0-0 19-0-0 26-0-0 7-0-0 6-0-0 6-o-0 7-0-0 ■JRM1iPMPwGAAl#10463CM,KrErba11114 43CMXrE4E•aAkYrLMrArEcir] LOADING (psf) SPACING _. 2-0-0 CSI DEFL in '(loc) I/deFl PLATES GRIP TCLL 20.0 Plates Increase 1.25'`- TC 0.27 Vert(LL) -0.12 9 >999 M1120 220/195 TCDL 14.0 Lumber Increase' 1.25 BC 0.44 Vert(TL) -0.27 9-10 >999 BCLL 0.0 Rep Stress Ince- YES WB 0.57 Horz(TL) 0.09 6 BCDL 7.0 Code UBC97/ANSI95 1st LC. LL Min Well =.240 Weight:. 127. Ib. r. LUMBER ' BRACING TOP. CHORD 2 X 6 OF No.2-G TOP. CHORD Sheathed or 4-6-1. oc purlins. BOT. CHORD 2 X 4. DF No.18Btr-G BOT. CHORD Rigid ceiling directly applir 10-0 0 oc bracing. WEBS - 2X4, DF Std -G IV/ REACTIONS (Ib/size) 2=1200/0-3-8,6=1200/0-3-8 Max Horz 2=31 (load case 2)" . Max Uplift 2=-57(load case 2), 6=-57(load case 3) - 4 �i��CO, FORCES (Ib)' -.First Load Case Only d •Ap TOP. CHORD 1-2=14,2-3=-2749,3-4=-1932, , 4-5=-1932, 5-6=-2749, 6-7=14 �^� /s'O BOT. CHORD 2-10=2638,9-10=2638,8-9=2638,6-8=2638 WEBS 3-10=90, 4-9=602, 5-8=90, 3-9=-816: 5-9=-816 NOTES 1) This truss has been checked for unbalanced loading conditions. 2) This truss has been designed for the wind loads generated by 80. mph winds at 25 ft above ground level, using 14.0 psf top chord dead load.and 7.0. psf bottom chord dead load, 100. mi from hurricane oceanline, on an occupancy, category I, condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE 7-93 per. UBC97/ANSI95 If end verticals or cantilevers exist, they are exposed to wind... If porches exist, they are not'exposed to wind.The lumber. DOL increase is 1.33, and the plate grip, increase is 1.33 J . 3) A plate rating reduction of 20% has been applied for the green lumber members. 4) Provide mechanical connection (by others) of truss to bearing plate capable'of withstanding 57 lb uplift atjoint'2 and 57, lb uplift at joint 6. 5) This truss has been designed with ANSI/TPI 1-1995 criteria. pF ES$/ OQR ql�� • C. AN� LOAD. CASE(S) ��� �� 1) Regular. Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf)17180 z M Vert: 2-6=-14.0,1-4=-68.0, 4-7=-68.0 • 2) Wind Left: Lumber Increase=1.33, Plate Increase=1.33 EXP. OB/3O/O5 Uniform Loads (plf) . , • Vert: 2-6=-.14.0,1-2=37.5, 2-4=14.2, 4-6=6.6,6-7=30.0 Horz:,1-2=-65.5, 2-4=42.2, 4-6=34.6, 6-7=58.0' CIV O- �P AitiritYdd?oWKe•2Verify design parameters and READ NOT ES.ON THIS AND REVERSE SIDE BEFORE USE Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and Is for an individual Jul 23,2004 y building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of building designer - not truss designer. Bracing shown Is for lateral support of Individual ^• web members only. Additional temporary bracing to insure stability during construction is the responsibility of the erector.�� rte Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection, and bracing, consult OST -88 Quality Standard, DSB- ' 89 Bracing Specification, and HIB -91 Handling Installation and Bracing Recommendation available from Truss ! 'Plate Institute, 583 D'Onotrio Drive, Madison, WI 53719 - MiTek Industries, Inc. ' I� a Symbols Numbering System ®General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury 'Center plate on joint unless dimensions indicate otherwise. Dimensions are in inches. Apply 1. Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property securely seat. owner and all other interested parties. J2 J3 J4 2. Cut members to bear tightly against each ,. TOP CHORDS other. 4 ��$ ~J5 C2 C3 3. Place plates on each face of truss at each C' p , 3 joint and embed fully. Avoid knots and wane 0 U �, 3 O at joint locations. U ,,h = " U 4. Unless otherwise noted, locate chord splices d O at '/< panel length + 6" from adjacent joint.) p 9 (- 1 1 ) ' For 4 x 2 orientation, locate Ce BOTTOM CHORDS ce 0 ~ ~ 5. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. plates 1/8" from outside edge J 1 J8 J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator. General FARTHEST TO THE LEFT. practice is to Camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT 8. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. 4 4 The first dimension is the width 9. Lumber shall be of the species and size, and x perpendicular to slots. Second in all respects, equal to or better than the dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins ICBO 3907, 4922 provided at spacing shown on design. LATERAL BRACING SBCCI 9667,9432A 11. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, Indicates location of required WISC/DILHR 960022-W, 970036=N unless otherwise noted. continuous lateral bracing. NER 561 ' ' 12. Anchorage and / or load transferring connections to trusses are the responsibility of - others unless shown. - 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints atME 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. engineer. MiTek® 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 © 1993 MiTek® Holdings, Inc. Jobe � Truss Truss Type _ Qty Ply + ' 812989969 RAUL1 A2 COMMON _ 24 1 (optional) KBI Norcal, Marysville; Ca.. 95901 4.201:'. SRI Nov. 16,2000 MiTek Industries, Inc. Fri Jul 23 15:35:15 2004 Page 2 LOAD CASE(S) y f 3) Wind Right:, Lumber Increase=1.33, Plate Increase=1.33 a f Uniform Loads (plf) t Vert: 2-6=114.0,11-2=30.0, 2-4=6.6, 4-6=14.2, 6-7=37.5 Horz: 1-2=-58.0, 2-4=-34.6, 4-6=42.2, 6-7=65.5 t r 4) 1st Wind Parallel: Lumber Increase=1.33, Plate Increase=1.33 r Uniform Loads (plf) Vert: 2-6=-14.0,1-2=30.0, 2-4=6.6, 4-6=6.6, 6-7=30.0 Horz: 1-2=-58.0, 2-4=-34.6, 4-6=34.6, 6-7=58.0 } - 5) 1st unbalanced Regular: Lumber Increase=1.25, Plate Increase =1.25 s Uniform Loads (plf) , Vert: 2-6=-14.0,'1-4=-68.0, 4-7=-28.0 6) 2nd unbalanced Regular. Lumber Increase=1.25, Plate Increase=1.25 + Uniform Loads (plf) #' Vert: 2-6p-14.0, 1-4=-28.0, 4-7=-68.0 y f,• Ir r ®WARNING - Verify design parameters and READ NOTES ON THIS AND REVERSE SIDE BEFORE USE Design valid for use only with MITek connectors. This design is based only upon parameters shown, and Is for an Individual building component to be installed and loaded vertically. Applicability of design parameters and proper Incorporation of component is. responsibility of building designer - not truss designer. Bracing shown is for lateral support of Individual , web members only. Additional temporary bracing to Insure stability during construction is the responsibility of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, erection, and bracing, consult OST -88 Quality Standard, DSB- 89Bracing Specification, and HIB -91 Handling Installation and Brecing Recommendation available from Truss Plate Institute, 583 D'Onofrlo Drive, Madison, WI 59719 - MITek Industries, Inc. • ' ' Symbols Numbering System ® General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury 'Center plate on joint unless dimensions indicate otherwise. Dimensions are in inches. Apply l . Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property securely seat. owner and all other interested parties. J2 J3 J4 2. Cut members to bear tightly against each �/g TOP CHORDS other. c2 c3 J5 3. Place plates on each face of truss at each c, 3 joint and embed fully. Avoid knots and wane 0 V �, 3 0 at joint locations. �+ U �5 U 4. Unless otherwise noted, locate chord splices CL 0- at Y< panel length (± 6" from adjacent joint.) For 4 x 2 orientation, locate ~C8 C7 C6 0 BOTTOM CHORDS 5. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. plates 1/8" from outside edge J 1 J8 J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator. General FARTHEST TO THE LEFT. practice is to camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT 8. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements.. 4 4 The first dimension is the width 9. Lumber shall be of the species and size, and x perpendicular to slots. Second in all respects, equal to or better than the dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins ICBO 3907, 4922 provided at spacing shown on design. LATERAL BRACING SBCCI 9667,9432A 11. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, Indicates location of required WISC/DILHR 960022-W, 970036-N unless otherwise noted. continuous lateral bracing. NER 561 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints atM1 ® 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. engineer. MiTek® 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 © 1993 MiTek® Holdings, Inc. NOTES RESIDENTIAL PERMIT NO. C��� ' C�6 G ��_/ d03-0161 Soria, Erasmo, owner s extend ex decks' y SPECIAL CONDITIONS CHECKED SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER { i f Y JOB FINALED (Dat Q F 'F Signature •it -i e 1 1 SPECIAL CONDITIONS CHECKED SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER { i f Y JOB FINALED (Dat Q F 'F Signature J=OK 0 = Not OK . = Not Readyable Card B-1 Date Card B-1 MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 2. 1. Zoning Requirements -Setbacks -Easements Gas; MH Test -Demand -Valve -Connector 2. Soils; Special MH SupportSketch 5. 3. Sewer; Location -Test -Fall -C/O -Concrete. Water; MH Test -Regulator -Connector 4. Water; Location -Test -Easement Needed (Sketch) 8. 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Tie Downs -Type -Installation Cert: 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG 11. 7. Well Clearance & Disconnect Date 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged "9. Tie Downs -Type -Installation Cert: 10. Exits; Insp.-Sketch 11. Cert., of Occupancy. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) . 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas -and Electricity. Tagged 9. Exits 10. License Decals 11..Verifv #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS ERS, CARPORTS, GARAGES (Plans) OK except #'s 4. ng Requirements -Setbacks -Easements Footings; Soils -Size -Depth -Spacing -Connectors -Steel Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails Wood Awn.; - Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Light Niche 12. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI - 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes -Enclosures- Panel boards- Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date. Card B-1 J=OK 0 = Not OK - = Not Applicable s = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 48. Cling. Joist-Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 57. Siding -Nailing Veneer 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 60. Shear Walls; Nailing -Bolts t 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 61. Brace Interior/Exterior Wall Panels 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test Card B-1 Date Card B-1 12. Electric Underground Date 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 16. Insulation 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa Date 69. Elec. Trim & Subpanel, Breaker Sizes & Labels Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 75. Garage Fire Door; Swing -Landing -Closure 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 78. Plb.; Elec. & Mech. Equip. Listed for Location 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 81. Guard Rails & Deck Construction -Post Caps 23. Fire Sprinkler; Test Clearance Looked under Floor O Yes _ Date Card B-1 Date Card B-1 Date 85. A.C. Unit Disconnect, Electrical -Plumbing Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 87. Water Well, Disconnect, Electrical, Plumbing 24. Fixture & Transformer Clearance -Ins. Protection 25. Elec. Receptacles Spacing -Lights & Switches at Doors 90. Glass Protection 26. Size Boxes & No. of Conductors Stapled 27. Romex Installed Close to Edge of Studs & C.J. 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 94. Energy Compliance Certificate -Other Certificates 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al Card B-1 Date Card B-1 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or AI Insulated Neutral El Yes O No Date 32. Service -Riser Conductors & Ground Main Disconnect 33. Equip. Clearances Panels-Motors-Mech. Equip. 34. Clothes Closet Light -Shower Light -Spa Light 35. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet. 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts t 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes _ 83. Following Instld./Drive O Yes O No/Walks O Yes O No/Planters 0 Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: V COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 03-0161 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541.10�2JR&A2 (Rev. 12/96) APPLICATION AND PERMIT ASS ESSOVARCEL NUMBER 027-070-021 ZONING - BUILDING PERMIT OWNER TELEPHONE SO. FT. OCC. BUILDING VALUATION 1242 C N gx MEM .OWNERS MAILING ADDRESS 2460 Maple Avenue Oroville CA 99q9A 8694.00 CONTRACTOR'S NAME owner TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 8694'oo ARCHITECT OR ENGINEER LICENSE No. Filing Fee S 20.00 Permit Fee s 108.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 70.20 BUILDINGADPREss _. _ _ _- - - - _ 2460_ Maple Avenue_'__,.? T Energy Plan Checking Fee $ $ PERMIT FEE $198.20 LOT NO. SUBDNISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ T-- - - — - Describe Work: extend. _exis_tinQ deck Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 600VOR LES Main Service zo.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service TO 46.00SO WEE200A CCU000A NEW CONST. DWELLING OCCUP. OR ADDNS. ( & ACC. BIDS. SO 3.5¢FT. =R.ID MULTI.OUTLET @7,50 b SINGLE APPARATUS OUTLET C IR. Ex. Occup. OUTLET OR FIXTURES 20 o 1,00 BAL @ .50 Ex. Occup. oU�TLEEDTS AES.6j EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE _ MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X S n Y l c Date 03 Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent OSHA permit is required for excavations over 5'0" deep and demolition or construction/tfY/ of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 198.20 HAZ. D. FEES IMP FLOOD CDF pARC0. PD HD ISSUE This permit is hereby issued under the applicable of the Butte County Code and/or Resolutions indicated above for which fees have been gAn By yam' Dat PERMIT EXPIRES ON provisions to do work paid. '1 3 D t/ to Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT i + v , � E.H. USE OA11.Y Plot Plan AnecM Ffcaa Man Anschad _ Sam to B.D. TO: Building Department FROM: Environmental Health ` SUBJECT: Sanitation Clearance y Owner . Location AP# Plan Approved for: Sewage Disposaa Water Supply: Public Private Well Clearance for dwelling. Other Hold final for: Final clearance O.K. for - NOTE: Environmental Health Specialist 8/96 Date ._s,;'c'��� .'ids ''S' v�.q.'t%'v.Td�o'b'+E'i'176':.'-i rF1a',,-.��r'�^�1'u'''4ti1.t✓"�� '=y+�w .�'+°��i-..sy COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: `J Gr ASSESSOR PARCEL NUMBER cad c��10 • �a Proposed Building Use: X/� �p dQ [� Counter Technician: Date: Items required in order to -apply -Mr a permit. All boxes MUST be checked OR rked NA in order to apply. 1.. Plot plans, 3 or 4 sets, signedity the preparer of the plans. Complete plans, 3 or 4 sets, signed by the preparer of the plans. �2. . Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. 04 ' 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Energy compliance design and supporting documentation in duplicate. ❑ 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The.permit will be indexed and returned to the plan review line-up when required items are received. Date Received By AA 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... ❑ 12. Hazardous Material Form............................................................................... _ ❑ 13. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ❑ 14. Fees as shown on the attached Schedule of Fees Due Sheet ....................................... _ St ent of Intent for Non -heated and A/C Buildings ............................................. _ itation and plot plan approval from the Environmental Health Department in 7. City of Chico Plumbing permit........................................................................ _ 18. California Department of Forestry plan approval ❑ paid. Sent_ by: ...................... _ ❑ 19. Planning approval for (A) Use: (B)Parking: . (C) Parcel Check: _ ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... _ ❑ 21. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... ❑ 26. Letter of Signature authorization.................................................................... ❑ 27. Recorded copy of Agricultural Acknowledgment Statement .................................... ❑ 28. Manufactured home utility clearance............................................................... ❑ 29. Existing violations and/or expired permits......................................................... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: When issued Telephone and hold for pickup. I have been:informed of the above items and requirements for obtaining a building permit. Applicant: A S M 0 S 6 Y i `C - Date: 1. Index permit application for the above items numbered: Plan Check Letter 2. Additional items required Contractor, designer, owner, was advised cf the above data by ❑ phone, ❑ mail, ❑ counter, by Date: _ Contractor, designer, owner, was advised of the ab ve to by ❑ phone, ❑ mail, Elcou ter, by Date: Plans reviewed by:A. Date: / a3 D 3 Plans approved by:, Date: Structural reviewed by: Date: a Structural approved by: Date: % Note transfer by: Date: Yellow- Rnildino nivicinn y OWNER -BUILDER •VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name, and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in , processing and issuing your verification is received. building permit. No building ,perm_ it will be ,issued until this I personally plan to provide the major labor and materials' for' focon'struction'of the' ed y » 11 . f u j property improvement,: YES ❑ ,NO ❑ y I HAVE ❑ - HAVE NOT ❑ signed an application for a building permit for the osed work. I have contracted with the following person (firm) to provide`the proposed struction: AME: RESS: CITY: PHO CONTRACTOR'S LIC SENO. 4. I plan' to pr vide portion of this work, but I have ed_ the following person to coordinate, supervise, and ovide the major work: ' , NAME: ,. ADDRESS: CITY: - PHONE: NTRACTOR'S LICENSE NO. } - 5. I will provide some of the w but1l have contracted (hired) the following persons to provide the work indicated: NAME ADD S ' PHONE " TYPE OF WORK ----------------- SIGNED: PROPERTYOWNER:%a DATE.Sen et� NOTE. This Owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety'Code. This,,verification= must be completed and + returned toour office before we are permitted to issue the permit ` OVER ^ O.B.- ; 1 I OWNER BUILDER INFORMATION I Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: ♦ If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. ♦ If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. ♦ There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. ♦ For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "owner builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. +rely,/ A Vi ira, C.B.O. ,uilding Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. OVER NaES RESIDENTIAL 027.070 021E 00-2411 • - � PERMIT NO. t ..._..ERASMO, SORIA __ ...._... _ _. 2460 MAPLE AVE., OROVILLE CONTR: OWNER t • OPEN & COVERED DECK � f r SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER 45 S JOB FINALED (Date)Z— �5 Signature .e = OK , 0 = Not OK. - = Not Applicable = No[ Ready; MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks -Easements 1. 2. Soils; Special MH Support Sketch 2. 3. Sewer; Location -Test -Fall -C/O -Concrete 3. 4. Water; Location -Test -Easement Needed (Sketch) 4. 5. Electricity; Location- Clearances-Grnd-/ /Amp -Concrete 5. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / /'Nat. or/ /"L"ft./ PLPG 6. 7. Well Clearance& Disconnect 7. 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances. 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged - 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 t A I e ,MISCELLANEOUS Date DEC WCOV ARPORTS GARAGES (Plans) OK except #'s AL / oni equirements-Setbacks-Easements otings; Soils -Size -Depth -Spacing -Connectors -Steel 3. 4. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails Wood Awn.; Posts- Beams- Rttrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric + 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -landings 12. Braced Wall Panels Date y Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date • FINAL (Plans) OK except #'s 1. Setbacks -Easements ` 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GF1 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main.in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche r Date Card B-1 Date Card B-1 I Date Card B-1 Date . Card B-1 R y , i = OK 0 = Not OK - = Not Applicable =Not Ready RESIDENTIAL (; Date FRAMING (Continued) Underfloor (Plans) OK except #'s 46. 1. Zoning -Setbacks -Easements -Flood -Slope 47. 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 48. 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 49. 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 50. 5. Stemwalls, Main; Steel-Blockouts-Wrapped 51. 6. Stemwalls, Garage; Steel- Blockouts-Wrapped 52. 6a. Hold Downs and Special Anchors 53. 7. Slab, Steel -Wrapped 54. 8. Piers -Fireplace Ftg.-Steel 55. 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 56. 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 57. 11. Water Pipe; Test -Anchors -Regulator -Service Test 58. 12. Electric Underground 59. 13. Plenums & Ducts; Clearance -Material -Support -Ins. 60. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 61. 15. Access & Ventilation 62. 16. Insulation Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 69. Stairs & Rails Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Elec. Outlets at Wood Panel, Int. & Ext. ELECTRICAL (Permit) OK except #'s 72. 23. Fixture & Transformer Clearance -Ins. Protection 73. 24. Elec. Receptacles Spacing -Lights & Switches at Doors 74. 25. Size Boxes & No. of Conductors Stapled 75. 26. Romex Installed Close to Edge of Studs & C.J. 76. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 77. 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 78. 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or Al 79. 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or AI Insulated Neutral 0 Yes ❑ No 80. 31. Service -Riser Conductors & Ground Main Disconnect 81. 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 82. 34. Smoke Detector 83. Stucco Brown -Finish Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Water Well, Disconnect, Electrical, Plumbing 35. A.C. Ducts Insulation & Support Exterior Elec. Trim, G.F.I. Receptacle -Underground 36. Vent Fan, Exhaust above insulation Ventilation Throughout House 37. Condensate Drain & Overflow, Size & Grade Glass Protection 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet Corrections from Previous Inspections 39. Attic Access & Platform if Furnace in Attic Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Date 40. Sits Proper Materials & Anchors Card B-1 Date Card B-1 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound Comments at Final: 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing • jingle & Duplex) Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 82. FoHowing Instld./Drive J Yes ] No/Walks J Yes J No/Planters Yes ] No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: C.2UNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT ez9-- 411 ASSESSOR PARCEL NUMBER 027-070-021') ZONING BUILDING PERMIT OWNER ERASMO SORIA TELEPHONE 533-5705 SQ. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS 2460 ViTLE AVE. OROVILLE 95965 CONTRACTOR'S NAME OWNTR TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Flirt Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 13190 BUILDING ADDRESS SAMF Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome 8 Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other)v Describe Work: OPEN + COVEL.ED DECK Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 600V OR Main Service 200AOR. 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.8 License Class Lic. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License ML w r the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00NEW CONST. DWELLING OCCUR OR ADDNS. a ACC. BLDs. SO 3.5¢FT; T. R Off, INEW D. MULTI -OUTLET @7,50 OWELER APUTLETPARATUS PSINGOCIR. Ex. Occup. OUTLET OR FD(TURES 20 BAL @';55 0 Ex. Occup. OFlxUT R� ' OR. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. 1. X _(— _ Date / D �-� - %00 0 Sig ature of Applicant - Owner ❑ Contractor ❑ Agent An OSHA permit is required �r excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 227.90 HAZ. o FEES IMP .,�— X FLOOD CDF P EL PD HD ISSU This permit•is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. / G By to 1 PERMIT EXPIRES ON Q 2- M ReceiptNo. 308586 227.90 WHITE-D.D.S.-B.D. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT irii�iii: xf:�Y; •" ,x? -�" :7'.ai'?ti .�'. r ;L i". L s� Cd &NTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 PE"IT"PLICA TION DATA SHEET OWNER: 4 ASSESSOR PARCEL ER: , 'Proposed Building Use: wilding Inspector: Date: �/ -- At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By V1tems have been submitted-------------------------------------------------------------------------------------- io:plans, 3/4 sets, signed by the preparer of plans. ------------------------------------------------------------ ❑ 3 . Complete plans, 3/4 sets, signed by the preparer of plans. ----------------------------------------------------- r ❑4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ ❑6. Energy Design Compliance and supporting documentation. ---------------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. --------------------------------------------------------- 118. Hazardous Material Form. ------------------- =--------------------------------------------------------------------- ❑ 9. Manufactured Home data and installation instructions including Tie Down Specifications .-----------------= ❑ 10. Fees of $------------------------------------------------------------------------------------- ❑ 11. Impact fees as shown on the attached schedule. ----------------------------------------------------------------- ❑ 12. C - omia Department of Forestry plan approval/fees. --------------------------------------=-=---------------- 3. E ood elevation certificate. --------------/--�---'------------------------------------------------------------------------- anitation and plot plan app �ova�?`— Health Department. -----------------=------------------------- %ItE 5. City of Chico plumbing permit - ------------------------------------------------------------- --------------------- El 16. Plot plan and business license approval from the City of Biggs. ---------------------------------------------- ❑ 17. Planning approval for (A) Use: (B) Parking: -------------------------- ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- r ❑ 19. Encroachment Permit for driveway construction approval prior to occupancy) - ---------------------------- �.' ❑20. Pre -inspection for required Request to Building Inspector on (Date) 021. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ El 22. workers' Compensation carrier and policy number.----------------------------------------------------------- x ❑23. Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - ---------- ❑24. Letter of signature authorization. ----------------------------------------------------------------------=-=------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utilityclearance.------------------------------------------------- �.; ------=------------------- ❑28. Existing violations and/or expired permits - -------------------------------------- ----------------- 1129. 0433 A, []Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ --------------- ❑30. Other: When you issue the permit, process as follows ❑ Mail to owner, 11 to c ntractor. ►ti'felerhone 3 `� / � and hold for.pickup at office. ❑ Deliver with inspector. Applicant: /)10 Cl 1 !,- Date: / 0 ' 20 0 U Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution_Date: By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Div'sion counter, by Date: w Plans reviewed by: Date: Plans approved by: Date: (O�Q z9 Sets of plans on hold in 0 Plan Cabinet, 11 A.P. folder. Note transfer by: Date: E.N. ONLY �w R Plot Plan Attached •:—^' Floor Plan A ehed a Sent to a.D. / TO: Building Department ' FROM: Environmental' Health SUBJECT: Sanitation Clearance CAPS rnc� S�A,1lJ 2�1�U,.l� Owner Location AP# Plan Approved for: Sewage Disposal � Water Supply: Public Private Well Clearance for dwelling. Other p Hold final for: Final clearance O.K. for: ' (VOTE: Environmental Health Specialist. Date 8/96 Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing' your signature. . Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement: YES pC ] NO[ ]. ,., 2. I HAVE[ ] HAVE NOT[ ' ] signed an application for a building permit for the , proposed work. 3. I have contracted with the 'following, person (firm) to provide the proposed s construction: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO: 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: f NAME ADDRESS PHONE TYPE OF WORK J' [GNED: - - - PROPERTY OWNER: DATE: A=`z-- Z,C'i O Ci NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before . we are permitted to issue the permit. 0 OVER Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of property improvements specified. For your protection, you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: 0 If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. 0 There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under . State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "ownerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. P_lease_compiete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned.. . Slnl&rel , Michael C. Vie6a, C.B.O. Manager, Building Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. OVER �-�. -.. ,.. �..,.�,-.� .. _. F..� .,n.rGx.�t-;r-. _s:...... 1F. .!s.0.: 8p9'��' `„y,'.�•.d '. s;°'•+L'<`?''Lrf-!t,�R�a! r"' F` '"k'►v�c ,-.. ., .,...� -. 0277i7-0-02V` "! 99=2153 B ,x SOR IA, . Fra smo'' 2460'Ma.ple Av e, Palermo (conn%s' tg). Integrity 'Homes °? • r i+ 1 N � COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754] PERMIT NO. (Rev.12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 027-170-021 ZONING 1 BUILDING PERMIT ' V OWNER TELEPHONE SQ. Fr, OCC. BUILDING VALUATION OWNERS MAILING ADDRESS PAI-ERM0 AMR CONfiiQCyT�PATIn UIXIEC VIC TELEPHONE C+.7 .L1' CONTRACTOR'S MAILING ADDRESS CONSTRUCTION LENDER LENDERS MAILING ADDRESS Fireplace Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 23.00 ARCHITECT OR ENGINEERS MAIUNG ADDRESS Plan Checking Fee $ BUILDING ADDRESS 2460 KAPTA AVE PAI -E Energy Plan Checking Fee $ $ PERMIT FEE $ 4 .00 LAT NO. SUBDNISIONSNAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Ulilities ❑ Installation CJ Other ❑ Describe Work: OONVERT y90BILE H&W TO SARAGF BtLDING Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 Main Service A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. j.�s��{- License Class ;. Lic. NO. 1� wJ{,7 WNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors license Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO tOooA 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( 8 ACC. BLDS. s0 3.5¢FT. T. NON-F61p. MULTI.OLI CUTITS @7,50 POWER APPARATUS a SINGLE OLlILET CIR. r EX. Occup. OUTLET OR FIXTURES BAL ®I.00 .sa Ex. Occup. oFuT E�APP IXASID°Ea 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My worker' mpensation insur nce carrier and policy number are: Carrier {"(er(�1't Yl+' ( Al tJ Policy Number ... I j'i (The above sections need not be completed 0 the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. orf 1 X Date _ Signa ure f Appli ant - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE 4J UlU TOTAL FEE $ H- G. FEES IMP FLOOD CDF I PARCEL I PD HD 6SUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for y ich fees have been paid. r �! ,. �i By': 7 Date PERMIT EXPIRES ONITE-D.D.S.-B.D' ete rReceiptNo. t .. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754y.' PERMIT NO. (Rev.12/96) APPLICATION AND PERMIT g 3 ASSESSOR PARCEL NUMBER 027-170-021 ZONING BU I LD I N G P ER M IT OWNER ERASMO 0 TELEPHONE 533-5705 SQ. FT. OCC. BUILDING VALUATION 9-6 . OWNERS MAILING ADDRESS 2110 WILLIAMS AVE, PALERMO 95()�R OONTR E TY HOMES INC. TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation Is ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 23.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS Energy Plan Checking Fee $ PERMIT FEE $ 43.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation IN Other ❑ CONVERT MOBILE HOME TO STORAGE BUILDING Describe Work: Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home ISI GI W1 920.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. �j License Class Lic. No. ���0 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO l 46.00 NEW CONST. OWE C. GCS. SO U OR NS. ( a C. 3.5QFT. NEW CONS -OUTLET NON -RES DT MULTI CIRCUITS -OUTLET 97.50 POWER APPARATUS A SINGLE OVRET CIR. 20 @ 100 EX. OCCU OUTIErOR FIXTURES BAL p .so Ex. Occup. OurLEEDTSA R -.GEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirino 23.00 PERMIT FEE _ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the C performance of the work for which this permit is issued. I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers,'.compensation insurance carrier and policy number are: Carrier t&�Yl gg CiN- YU9 WR 2 ., MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEI= $ Policy NumberQ, �f� % -� %��' L''�_ (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if 1 should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. W X Date— Signature bf Appli ant - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures overstories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST. TYPE43.00 TOTAL FEE $ FEES IMP I FLOOD I CDF I PARCEL I PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County ode and/or Resolutions to do work indicated above for ich fees have been paid. r IN By Date PERMIT EXPIRES ON 9-6 —1 Date '3 Receipt No. aZ `601 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT ��.�~r+'a�Y+ ,-s,,,✓ •-.^:';1_�,�..1+'^ti�.-.'=r�.•1...?fY.-.w.w�s.:;j,...y�..��.n'.-1..:.�y^.JS.-'�...,y..•�ti.-� ..,* . - .. .. �. _ ..r .. a:.., _• � ,� School District A.P. Number Property Owner BUTTE COUNTY SCHOOLS IMPACT.FEE-CERTIFICATION FORM (One form per Building) vl Building Department No. _ oa % — - Jurisdiction: City County Property Location/Ac Subdivision Residential Development No of Living Units Commercial/Industrial 0 New Lot No. Sq. Footage (40f Mobile Home Addition] *Supplemental to (Group R) Installation Conversion Permit #M4, Joo '(No foundation inspection); ...................................................... ... Addition Sq. Footage ( Including.•Exterior Roofed Areas) 7 A?� Date K . imoor rians revieweaaDy acnooi utstnct rersonneu District Identificabon No. 000048 , School Distract certifies thate . . (Applicant) D f�Ci AYE (Street Address) (City) has complied with the requirements of Resolution No. r I LNAA, School District Represe Paid by Check 1-�.. square feet. Remarks: (Phone Number) (Zip Code) by payment of $ .93% _ AB 2926 $ FULL MITIGATION $ i Date 1 . _ It tnAJ Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 660201a), within 90 days from the date fees are paid. Failure to submit a timely, written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) ` feeform.xis 110198)dmm 0 f NOTES ' '<;. r { RESIDENTIAiL _Akr 027-070-0211 _199-2056 PERMIT NO. ..,.,ERASMO,-� ORI'A­ ._ . `. 2460 MAPLE AVENUE, PALERMO CONTR. INTEGRITY HOMES, INC. ' > MH Od$ERM FND, EX SITE P k . THE HCD FORM 433A FOR THIS MH CAN NOT ��# 4 BE.RECORDED UNTIL:ONE OF-THE FOLLOWING •�� HAVE BEEN'�TURNED IN TO THE BLDG DIV: (1)4LICENSE PLATE(S) or DECAL(THE NSP .IECTOR MUST RETRIEVE) (2) STATEMENT OF FACTS(ONLY ON NEW MWS) ' INSPECTOR TO" VERIFY SERIAL &LABEL #'S f - - SPECIAL CONDITIONS CHECKED BY SRA F> FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. S,PEC.IAL-.I.N.S_PECTI,QN_IT_EMS OFFICE COPY .Address III GAS u Meter By Da ELECTRIC t, Meter By` Date -Z OR OR _ c;Z7 JOB FINALED (D",) _ 1 Signature 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILWAOME INSTALLATION (Plans) OK -except #'s Line Elect ' MH Test -Crossovers -Breakers -Clearances rain; MH Test -Fall -Flex Connector er; MH Test -Regulator -Connector ,platei and Sewer Connected -C/O to Grade -HD Approval 8. 'Gas and Electricity Tagged 9 Tie Downs -Type -Installation Cert. •. xits; Insp.-Sketch 11. Cert. ccupancy ermanent Foundation Only; License Decal _ t Date Z Card B-1 i Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. -Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Frg-Bracing 5: Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills -Anchors- Studs- Rftrs-Trusses 9. as'j =OK 10. Roof; Shthg-Roofing 0 Not OK 11. Ext.; Steps -Doors -Landings = Not Applicable 12. MOBILE HOMES = Not Ready ' Date MOBILE HOME UTILITIES (Plans) OK except #'s Card B-1 Date Card B-1 1, Zoning Requirements -Setbacks -Easements Card B-1 Date Card B-1 2. Soils; Special MH Support Sketch FINAL (Plans) OK except #'s 3. Sewer; Location -Test -Fall -C/O -Concrete Setbacks -Easements 4. Water; Location -Test -Easement Needed (Sketch) Soils; Compaction -Structure Stability 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Pool Structure; Steel -Connections -Thickness Dead Men -Lining 6. Gas; Location -Test -Wrap;-/ /" L'ft. Elec.; Receptacles and Lighting, Distance-GFI / P Nat. or/ /"L"ft./ /'LPG Elec.; Pool Lighting; 15 Volts-GFI 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILWAOME INSTALLATION (Plans) OK -except #'s Line Elect ' MH Test -Crossovers -Breakers -Clearances rain; MH Test -Fall -Flex Connector er; MH Test -Regulator -Connector ,platei and Sewer Connected -C/O to Grade -HD Approval 8. 'Gas and Electricity Tagged 9 Tie Downs -Type -Installation Cert. •. xits; Insp.-Sketch 11. Cert. ccupancy ermanent Foundation Only; License Decal _ t Date Z Card B-1 i Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. -Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Frg-Bracing 5: Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills -Anchors- Studs- Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6, Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ,/ = OK 0 = Not OK = Not Applicable = Not Ready RESIDENTIAL (; Date Hangers -Post Caps -Anchors -Connectors Underfloor (Plans) OK except #'s Cling. Joist-Rftr. Ties-Purlin-Roff Brac.-Truss-Shting.-Rfng. 1. Zoning -Setbacks -Easements -Flood -Slope 49. 2. Fig., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 52. 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 5. Stemwalls, Main; Steel-Blockouts-Wrapped 55. 6. Stemwalls, Garage; Steel- Blockouts-Wrapped Siding -Nailing Veneer 6a. Hold Downs and Special Anchors 58. 7. Slab, Steel -Wrapped Shear Walls; Nailing -Bolts 8. Piers -Fireplace Ftg.-Steel 61. 9. D. W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Infiltration -Walls -Windows 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 79. 11. Water Pipe; Test -Anchors -Regulator -Service Test Water & Sewer Connected -C/O to Grade -HD Approval 12. Electric Underground Energy Compliance Certificate -Other Certificates 13. Plenums & Ducts; Clearance -Material -Support -Ins. Address Posted 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation Card B-1 Date Card B-1 16. Insulation Card B-1 Date Card B-1 Date Date Comments at Final: Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or At Insulated Neutral O Yes ❑ No 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35. A.C. Ducts Insulation & Support 36. Vent Fan, Exhaust above insulation 37. Condensate Drain & Overflow, Size & Grade 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 39. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) e Date' FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roff Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor D Yes 82. Following Instld./Drive 0 Yes NO/Walks'J Yes ❑ No/Planters Q Yes :) No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: 1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIV N 7 County Center Drive • Oroville, Calif9rnia_ 95965 • Telephone (530) 538-7 PERMIT NO. (Rev.12/96) 4 f APPLICATION AND -PERMIT A55��7"' "liA8�21 ZONING BUILDINGPERMIT OW" , :AS rO SORIA. TELEPHONE 533--5705 SQ. FT. OCC. BUILDING VALUATION . OWNERS MAIUNG ADDRESS gun i f OO,TtY HOMES INC �N TE 533 4403 `T" '*SMA _.,1ssRIVEF BLVD, OROVILLE 95965 CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee 608/2 $ 304.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 2-J_. BUILDING ADDRESS � 60 � APTE AVE PAI ERMO Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Fling Fee '20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ XOther SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other .10 Describe Work: T;Tq1/PEP.M FDD1 EXISTING SITE Gas piping system 1 - 5 outlets 15.00 15.00 Building sewer 15.00 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE $ 65.00 ELECTRICAL PERMIT Fling Fee 20.00 OOOV OR Main Service zaOA OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in SII force and effect.k License Class CAI Lic. NO. 11, � �� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the. project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Ulu C/$ae Policy Number 41'9'b— ® -127/1 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. � ,,i7 X %" ,�L/Z'Zo �l`J�( JZ L�JI Datein/h /-___ Signatu�of Ap licant - ❑ Owner If Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. DW EWNG OCCUP. SO OR ADDNS. ( s ACC. S.3.5¢FT: INlpµp�ID. MULTI.OUTLET @7,50 POWER APPARATUS 8 SINGLE 011TLEr CIR. EX. Occup. OUTLET OR FIXTURES BAL @ 1.00 50 Ex. Occup. OUUTTLETS REESID.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE t 43..00 MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEI: $ Mobile Home Installation Fee $ Energy Inspection Fee $ .. Occ CONST. TYPE TO AL FEE $ 455/0 ,M FL000 coF PAR HD I ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By ate G EXPIRES ON ID to Receipt No. 274027 83.00 — ,PERMIT WHITE-D.D.S.-B.D. CANARY -ASSESSOR INK -INSPECTOR G N OD=APPLICANT j t � E.H. USE ONLY 'Rot Plan Attached Floor Ren Ariaehad Sant to B.D. l U TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance alpSv11� �er� z4 b �4�1�, 2� --C�-U ' 2 � Owner Location AP# Plan Approved for: Sewage Disposal— " Water Supply: Public Private Wel Clearance for dwelling. Other ' [�P Mot Y� YYLQ� Hold final for: Final cl.............., s.._. NOTE: Environmental Health Specialist 8/96 Date s ItK .,;. R(1" -'r ^e�`""'�-.+ti �. v'.r ..•*.'M7-'e��"1w�..rY�u+g+•.1��..e�'N."V.Os.�1, li!� A�4rAFy di...I'7Y7�'J.3�^[.�iiY"•Wti 'tI'-`'%ti'j—r :. ..ti.f�..'* �,,..� OUNTY OF BUTTE - DEPARTMEtrJf*jOV6EPtYIENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER,DRIVE - OROY L K1VIA 95965 - TELEPHONE (530) 538-7541 PERMIT APFLICAiIO�NDATA SHEET OWNER: gi2tjqG ASSESSOR PARCEL NUMBER: D 0—OoV Proposed Building Use: M H a4�o-iti :)j _ Building Inspector: L Date: 9—% At time of permit application, I was advised the following data must be eubmitted`prior to permit processing and/or issuance: cpj)( 5� i Date Received By ❑ 1. All items have been submitted ----------------------------------------------------------------------------- ti 02. Plot plans, 3/4 sets, signed by the preparer of plans. ------------= 03. Complete plans, 3/4 sets, signed by the preparer of plans. ----------------------------------------------------- ❑4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ ❑ 6. Energy Design Compliance and supporting documentation.---------------------------------------------------- f ❑7. Statement of Intent for Non -Heated and A/C Buildings. ------------------------------------ -----------, ❑ 8. Hazardous Material Form. ----------------------------------------------------- ==---------------------------------- ` ❑ ` Manufactured Home data and installation instructions including Tie Down Specifications. ------------------ Fees of $ O -------------------------------- Impact fees as shown on the attached schedule. -------- -- ------------------------ ---------------- C"� California Department of Forestry plan approval/fees.-�--- =- 2 —9- �- Flood elevation certificate- ---------------------------------------------------------------------------------------- Sanitation and plot plan approval U(�J((� Health Department. ------------------------------------------- I 15. City of Chico plumbing permit. -------------------------------------------------------------------------------------- ❑ 16. Plot plan and business license approval from the City of Biggs. ---------------------------------------------- 1 ❑ 17. Planning approval for (A) Use: O I<*-' �' (B) Parking: --------------------------— ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- ❑ 19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- El 20. Pre -inspection for required. Request to Building Inspector on (Date) 021. Contractor's license information. (Number, Name Style, Classification)- ------------------------------------ El 22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- / ❑23.Owner-Builder Verification (Given to owner ❑, Mailed to owner EI) - -------------------------------------- (� Letter of signature authorization. -------------------------------------------------------------------------------- Recorded copy of Agricultural Acknowl gment Statem t. -------------- --j--------- --- ----------- 6' Letter of intent on building use. -� J�Y1!_`--�%'L4D--ff ------------------ ❑27. Manufactured Home utility clearance. ------------------------------------------------- -------------------------- ❑28* Existing viol 'ons and/or wired ired p 29. E1433Deed, .HO�. Titl Ch to H.C.D $ aa' y _____________ 113 0. Other: ------ h -/ � 9S When you issue the permit, process as follows ❑ Mail to owner, (❑]Mail to c ctor. �elephone S33-4403 and hold for pickup at v ��l ftraoffice. ❑ Deliver with inspector. Applicant: 0& Date: ` Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, o Air ollution Date: By: Copy of plans sent ❑ Health Department, o Fire Departme o O Date: By: 1. Index permit application for the above items numbered: O ❑ Plan Check List 2. Additional items required: AWAArt((n s lafl Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, o mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, o'Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by o phone, ❑ mail, ❑ Buildin Di Bron counter, by Dat�j�-- Plans reviewed by: Date: -Plans-approved by: Date: Sets of plans on hold in ❑ Plan Cabinet, 11A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. I' AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 1999-0Q139'Ea 70 Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 11:42AM 14 -Sep -1999 REC FEE 7.00 PRINT P 1.00 Myles Page 1 of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this p� property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Subdivision No. 1 of the Palermo Citrus Tract, according to the Official Map thereof filed In the office of the Recorder of the County of Butte, State of California, July 23, 1888, described as follows: COMMENCING at the Northwest comer of said Lot 3 In Block 117, which point is Identical with the centerline Intersection of Maple and Citrus Avenues; thence South 80 26' East 413.90 feet to an Iron pin In the center of the Oroville-Wyandotte Irrigation District Canal; thence South 20 58' East 259 feet along afore said Canal to a point on the Wast benn on the Canal, said point being marked by an Iron stake and R E. Tag No. 2435; thence North 38 26' West 7.83 feet to an iron pin; thence South 2219' East 459.7 feet to a point on the lot line between Lots 2 and 3 of Block 117 of Palermo Citrus Tract; thence North 30 26' West 673.6 feet to a point In the center of Citrus Avenue; thence North 660 feet along the centerline of Citrus Avenue to the point of beginning. EXCEPTING THEREFROM all that portion of the Southwest quarter of Lot 3 in Block 117 of Addition to Subdivision No. 1 of the Palemu Citrus Trac:, according.to.the Official Map thereof filed in the office of the Recorder of the County of Butte, State of California, July 23, 1888, described as follows: COMMENCING at the Northwest comer of said Lot 3 in Block 117 at the centerline intersection of Maple and Citrus Avenues; thence South along the centerline of Citrus Avenue, a distance of 369.00 feet to the true point of beginning, thence from said We point of beginning, parallel to the North line of said Lot 3, South 88 26' East a distance of 249.00 feet; thence South a distance of 119.00 feet; thence parallel to the North line of Said Lot 3, North 88 26' West, a distance of 249.00 feet to a point on the centerline of Citrus Avenue; thence North along the centerline of Citrus Avenue a distance of 119.00 feet to the true point of beginning. Date 9—/� 1g�I % PROPERTY OWNERS: State of California County of BUTT& On 9-13-99 'r 1 r1 Srnt� i� rr.�- i�fro((liCQ,I Q f ° C' CHARITY D. BERRY F Notmy Pub11c 806 County, COROW0 s . . before me, CHARITY D . , BERRY JC=MW0n#1178386MfrCPS? MY CctnMMon EV' APR' 3, 2002 personally appeared ERASMO SORIA AND t 'y 'I V Y Y Y Y AY � �— personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrunWit and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/t.eir signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrumeDt. ' WITNESt�my hand and,official seal. Signature_] Seal: A.P. # 0"2-0'70— O:.J i�'',� ) tik-. ••, oa..n ..r. sl t� YLtii�6v • t -RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO - BUTTE COUNTY,BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 7 x COPY of Document Recorded 23 -Nov -1999'. 1999-0049191 Has not been compared vith original BUTTE COUNTY RECORDER n ISPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME)`OR COMMERCIAL COACH, ` INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the , county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ' ERASMO SORIA BUTTE COUNTY BUILDING DIVISION ; REAL PROPERTY OWNER/LESSOR LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 2110, U-LIAMS AVENUE - 7 COUNTY CENTER DRIVE MAILING ADDRESS MAILING ADDRESS PALERMO, BUTTE_, CA 95968 OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP CITY COUNTY STATE ZIP 2460 MAPLE AVENUE 99-2056 (530)538-7541 INSTALLATION MAILING'ADDRESS, IF DIFFERENTB G PERMTC NO. TELEPHONE NUMBER PALERMO., BUTTE, CA 95968_fAjni CITY COUNTY STATE ZIP SIGNATURE OF LOCAL A Y OFFICIAL DATE - SAME NONE UNIT OWNER (if also property owner, write 'SAME') DEALER NAME (if not a dealer sale, write 'NONE") MAILING ADDRESS DEALER LICENSE NO. QR coO SUTE • ZIP y UNIT DESCRIPTION CHAMPION 1999 MEADOWCREEK MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAME/NUMBER 0900-741011274—MC741/2 66',X 26' TRA468777/8 SERIAL NUMBER(S) LENGTH X WIDTH • INSIGNWLABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ti ASSESSOR'S PARCEL NUMBER A.P. #027-070-021' . SEE ATTACHED HCD FORIM 433(A) REV. 8/91 ' r WHITE - County Recorder ' CANARY_- HCD PINK - Applicant GOLDENROD - Budding Dept ' !— d .y 7 x COPY of Document Recorded 23 -Nov -1999'. 1999-0049191 Has not been compared vith original BUTTE COUNTY RECORDER n ISPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME)`OR COMMERCIAL COACH, ` INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the , county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ' ERASMO SORIA BUTTE COUNTY BUILDING DIVISION ; REAL PROPERTY OWNER/LESSOR LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 2110, U-LIAMS AVENUE - 7 COUNTY CENTER DRIVE MAILING ADDRESS MAILING ADDRESS PALERMO, BUTTE_, CA 95968 OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP CITY COUNTY STATE ZIP 2460 MAPLE AVENUE 99-2056 (530)538-7541 INSTALLATION MAILING'ADDRESS, IF DIFFERENTB G PERMTC NO. TELEPHONE NUMBER PALERMO., BUTTE, CA 95968_fAjni CITY COUNTY STATE ZIP SIGNATURE OF LOCAL A Y OFFICIAL DATE - SAME NONE UNIT OWNER (if also property owner, write 'SAME') DEALER NAME (if not a dealer sale, write 'NONE") MAILING ADDRESS DEALER LICENSE NO. QR coO SUTE • ZIP y UNIT DESCRIPTION CHAMPION 1999 MEADOWCREEK MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAME/NUMBER 0900-741011274—MC741/2 66',X 26' TRA468777/8 SERIAL NUMBER(S) LENGTH X WIDTH • INSIGNWLABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ti ASSESSOR'S PARCEL NUMBER A.P. #027-070-021' . SEE ATTACHED HCD FORIM 433(A) REV. 8/91 ' r WHITE - County Recorder ' CANARY_- HCD PINK - Applicant GOLDENROD - Budding Dept ' ::::::::::::::::::::;::::::::: :::::::.::.::::::.:::.......:.:::..::.::::..:.:........:..............................................................................X. ..............:....:► :�::::.:::::.::.::::::.::::::::::::::....::::::::: X. BUILDING PERMIT NUMBER: 99-2056• Address or location of unit: 2460'MAPLE AVENUE, PALERMO, CA 95968 ' Legal, Description of Real Property:` A.P. #027-070-021 - SEE ATTACHED (z) Mobilehome/Manufactured Home _ O Commercial Coach t Has been affixed to the real -property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: ERASMO SORIA : • - A Owner's address: ' ' 2110 WILLIAMS AVENUE, PALERMO, CA 95968 INSIGNIA OR HUD NUMBER:. TRA46�8777/8 � r SERIAL NUMBER_ OR V.I.N.: 0900-741-11274=MC741/2 - MANUFACTURER'S NAME: CHAMPION 'YEAR: 1999 OFFICIAL APPROVING INSTALLATION: L a DATE:. 11/19/99 PHONE: (530) 538-7541 ; H.C.D.513C �, f, ::::::::::::::::::::;::::::::: :::::::.::.::::::.:::.......:.:::..::.::::..:.:........:..............................................................................X. ..............:....:► :�::::.:::::.::.::::::.::::::::::::::....::::::::: X. BUILDING PERMIT NUMBER: 99-2056• Address or location of unit: 2460'MAPLE AVENUE, PALERMO, CA 95968 ' Legal, Description of Real Property:` A.P. #027-070-021 - SEE ATTACHED (z) Mobilehome/Manufactured Home _ O Commercial Coach t Has been affixed to the real -property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: ERASMO SORIA : • - A Owner's address: ' ' 2110 WILLIAMS AVENUE, PALERMO, CA 95968 INSIGNIA OR HUD NUMBER:. TRA46�8777/8 � r SERIAL NUMBER_ OR V.I.N.: 0900-741-11274=MC741/2 - MANUFACTURER'S NAME: CHAMPION 'YEAR: 1999 OFFICIAL APPROVING INSTALLATION: L a DATE:. 11/19/99 PHONE: (530) 538-7541 ; H.C.D.513C �, t LEGAL DESCRIPTION A.P. #027-070-021 All that certain real property situate in the County of Butte, State of California, described as follows: A PORTION OF LOT 3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "ADDITION TO SUBDIVISION OF THE PALERMO CITRUS TRACT", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 23, 1888, DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 3 IN BLOCK 117, WHICH POINT IS IDENTICAL WITH THE CENTERLINE INTERSECTION OF MAPLE AND CITRUS AVENUES; THENCE SOUTH 88 DEG. 26EAST, 413.90 FEET TO AN IRON PIN IN THE CENTER OF THE OROVILLE-WYANDOTTE IRRIGATION DISTRICT CANAL; THENCE SOUTH 20 DEG. 56EAST, 259 FEET ALONG AFORESAID CANAL TO A POINT ON THE WEST BERM OF THE CANAL, SAID POINT BEING MARKED BY AN IRON STAKE AND R.E. TAG NO. 2435; THENCE NORTH 88 DEG. 26WEST, 7.83 FEET TO AN IRON PIN; THENCE SOUTH 22 DEG. 19' EAST, 459.7 FEET TO A POINT ON THE LOT LINE BETWEEN LOTS 2 AND 3 OF BLOCK 117 OF PALERMO CITRUS TRACT; THENCE NORTH 88 DEG. 26WEST, 673.6 FEET TO A POINT IN THE CENTERLINE OF CITRUS AVENUE TO THE POINT OF BEGINNING. EXCEPTING THEREFROM ALL THAT PORTION OF THE SOUTHWEST QUARTER OF LOT 3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "ADDITION TO SUBDIVISION OF THE PALERMO CITRUS TRACT", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 23, 1888, DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 3 IN BLOCK 117 AT THE CENTERLINE INTERSECTION OF MAPLE AND CITRUS AVENUES; THENCE SOUTH ALONG THE CENTERLINE OF CITRUS AVENUE, A DISTANCE OF 369.00 FEET TO THE TRUE POINT OF BEGINNING; THENCE FROM SAID TRUE POINT OF BEGINNING, PARALLEL TO THE NORTH LINE OF SAID LOT 3, SOUTH 88 DEG. 26' EAST, A DISTANCE OF 249.00 FEET; THENCE SOUTH A DISTANCE OF 119.00 FEET; THENCE PARALLEL TO THE NORTH LINE OF SAID LOT 3, NORTH 88 DEG. 26' WEST, A DISTANCE OF 249.00 FEET TO A POINT ON THE CENTERLINE OF CITRUS AVENUE, A DISTANCE OF 119.00 FEET TO THE TRUE POINT OF BEGINNING. STATE `CALIFORNIA - DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT °4,�``md • DIVISION 0_F CODES, AND STANDARDS REGISTRATION AND TITLING SECTION STATEMENT OF (ACTS This unit is a: © Mobilehome ] Commercial Coach Floating Home Truck Camper Decal (License) No.(s) Trade Name Serial No.(s) • jl.{�A�JO�JC';P� X317 I/We, the undersigned; hereby state that the unit described above: , P to'c'ol a_ (�YM`o�r� 2rt�, ,c C����. oF� Affiant further agrees to indemnify and save harmless the Director of Housing and Community Development,. State of California, and subsequent purchasers-ofsaid unit, for any loss they may suffer resulting from registration of, the. above-described unit in California, or from issuance of...a California certificate of title -covering the same.' I/We certify under penalty of:perjury that the foregoing is true and correct: Executed on q 2•Ql �1� at (D G6 Rc— Le, (Date) •' (City) (State) , Sign a of each affiant ', Printed, name of each affiant Address �"i11. Y' Q' Y -d /�,�,�\ r City ��Vi �� �' ,State &`� nl� f '.,F • 1 'HCD 476.6 (Rev 11/86) I RECORDING REQUESTED BY MID VALLEY TITLE & ESCROW, CO.$UTTE CniJN 4ECORDER ' AND WHEN RECORDED MAIL TO: •, � • SERIAL NO. ERASMO R. SORIA RECORDED AT THE REQUEST OF 2460 MAPLE AVE MIO VALLE TITLE COMPANY! OROVILLE; CA 95966 • DATE RECORDED: 1 U TIME: ORO -C Space Above This Line for Recorder's Use Only A.P.N.: 017.070-021 Order No.: 175844 if Escrow No.: 175844PE-3 .GRANT DEED THE UNDERSIGN M' GRANTOR(s) DECLAItE(s) TIJAT DOCUMENTARY Tr1ANSFr-k TAX IS: COUNTY 64.90 X I computed on full value of property conveyed, or computed on full value less value of liens or encumbrances reinaining at time of sale, �) unincorporated area: [ I 'City of OROVILLE , and FOR A VALUABLE CONSIDERATION, Reccipt of which is hereby acknowledged, LOUISE PEARSON, AN UNMARRIED.WOMAN hereby GRANT(S) to ERASMO�SORIA� A ir1ARRIEO MAN; AS HIS,, SOLE ANO SEPARATE PROPERTY R. the following described property an Unincorporated'Area,'County, of Uutte State of Califnfma; See Exhibit "A" attached hereto and made a part hereof. igA LOUISE PEARSON BY ► THA J . YOUNG, HETTORNEY IN FACT Document Date: September 21: 1999 STATE OF CALIEORO )S5 COUNTY Of OU 1 , E ) On 10-6-99 before me, PENNY C. ENGLAND NOTARY PUBLIC personally appcartxl MARTHA J. YOUNG . ioved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscr personally known to me (or p -bed to doe within - ed Or9 me that helshelthcy executco the same In his/her/their aulhorited capacity(ies) and that by his/hcrMair sisnature(s) on instrument andntoM Ute instrument the knowledge acknowledged to the entity upon behal(of which the person(s) acted, oxecuted the instrument. WITNESS my hand and O(iicial seal. Signature T_ hit area for official notarial seal. ` NNY C GLAND FOON C. ENGLAND r Owvnisibn 01079122 Mir CPSI ® - Botta County. Cupomb W Cwwbslon Exp. DEC. 3,190 Mail lax Statements to: SAME AS ABOVE or Address Noted Below E00- Z9Z'ON 9ZT022G0£9 F 31IIA060 311I1 A3110n GlW OP: 60 "66/TE/OT ORDER NO. BU -175844-3 Y DZSCRYPTION EXHIBIT "A" THE LAND REFERRED TO IN THIS REPORT IS SITUATED IN THE STATE OF CALIFORNIA, COUNTY OF BUTTE, AND -IS DESCRIBED AS FOLLOWS: A PORTION OF LOT 3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "ADDITION TO SUBDIVISION OF THE PALERMO CITRUS TRACT", 14111CH MAP WAS RECORDED IN THE OFFICE OF THE ,RECOrRDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY •23, 1828, DESCRIBED AS FOLLOWS: COMENCING AT THE 1JORTHWEST COR2�T1R OF SAID LOT 3 IN BLOCK 117, WHICH POINT IS IDENTICAL WITH THE.CEhTERLINE INTERSECTION OF MAPLE y AND CITRUS 'AVENUES; ' TAENCE SOUTH IS DEG. 26' EAST, 413.90 FEET. TO AN IRON PIN, IN THE CENTER OF THE OROVILLE-WYANDOTTS' IRRIGATION DISTRICT CANAL; t•MNCL SOUTH 20 DEG. 56p EAST, ZS9 FEET ALONG AFORESAID CANAL TO A POINT ON'TRE WEST BERM, OF THE CANAL, SAID POINT BEING *:MARKED By AN IRON STAIC AND R.E. .TAG NO. 2435; THENCE NORTH 88 DEC. 26' WEST, 7.63 FEET TO AN IRON PIN; THENCE -SOUTH 22 DEG. 19' EAST, 459.7 'EF.T TO A POINT ON THE IAT'LINE BETWEEN LOTS 2 AND 3 OF BLOCK 117 OF PALERMO CITRUS TRACT; THENCE NORT:-1 o8 DEG. 26' WEST, 673.6 FEET TO A POINT IN THE CENTER OF CITRUS AVENUE; THENCE NORTH 660 FEET ALONG THE•CEN7EERLINOF CITRUS AVENUE TO The POINT OF BEGINNING. EXCEPTING THEREFROM ALL THAT PORTION OF THE SOUTIWE.ST QUARTER O: LOT .3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP UNTITLED, "ADDITION TO SUBDIVISION' OF TIM PALERMO CITRUS TRACT", WHICH. IAP . WAS RECORDED IN TFE-OFFICE OF TI. ..'RECORDER OF THE COUNTY Or BUTTE, STATE CF CALIFORNIA, ON JULY 23, 1886, DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 3 IN BLOCK 117 AT • � THE` CENTERi.IN£' INT:,RSECTION OF• MAPLE: AIvD CITRUS AVENUES; F'.E-NC • SOUTH ALONG THE CENTERILINE OF CITRUS AVENUE,^ A DISTANCE OF 369.00 FEET TO THE TRUE POINT Or SEGIVNIN0; THENCE FROM SAID, TRUE P01NT OF BEGINNI[:G, PARALLEL TO THE NORTH LIKE: OF SAID IAT 3, - SOUTH 88 DEG. 2G' i;AST, A DISTANCE OF 249.00 FEET; THENCE SOUTH A DISTANCE OF 119. 00. FEET; VENCE PARALLEL TO TI -42 14ORTH LINE OF SAID LOT 3, NORTH EB DEG. 26' WEST,. A DISTANCE OF 249.00 FEET TO A PDXNT .ON THE CENTERL=A'E OF CITRUS AVrME; &HENCE NORTH ALONG THE CENTERLINE OF. -CITRUS - AVENUE, A DISTANCE OF 219.00 FEET TO. THE TRUE POINT OF BEGINNING. £00 Z9Z ' ON, SZ1022S029 F 3-1-11f)080 311 I 1 ,131-1UA Q I W 0t7:60 66/TZ/OT . AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 1999—��49191 Recorded I REC FEE .00 OfficialRecordsI CONFORM .00 CountOff 'BUTTE CANDACE J. GRUBBS I Recorder I ROSEMARY DICKSON I Assistant I Maureen 09:55AM 23 -Nov -1999 I Page l of 2 SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ERASMO SORIA REAL PROPERTY OWNEMESSOR 2110 WILLIAMS AVENUE MAILING ADDRESS PALERMO, BUTTE, CA 95968 CITY COUNTY STATE ZIP 2460 MAPLE AVENUE .INSTALLATION MAILING ADDRESS, IF DIFFERENT ..PALERMO, BUTTE, CA 95968 CITY COUNTY SPATE ZIP SAME UNIT OWNER (dalso property owner, write "SAME") MAILING ADDRESS BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE; BUTTE, CA 95965 CITY COUNTY STATE ZIP 99-2056 (530)538-7541 B G PERM ITN+AY TELEPHONE NUMBER SIGNATURE OF LOCICIAL DATE NONE DEALER NAME (d•not a dealer sale, write "NONE") DEALER LICENSE NO. CRY Com rr STATE ffi UNIT DESCRIPTION CHAMPION 1999 MEADOWCREEK MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMEINUMBER 0900-741011274-MC741/2 66'X 26' W.468777/8 SERIAL. NUMBER(S) LENGTH X WIDTH INSIGNIA/LABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER A. P r#027-070-021. SEE ATTACHED HCD FORM 433(A) REV. 8/91 . WHITE. - County Recorder CANARY - HCD PINK - Applicant GOLDENROD - Building Dept LEGAL DESCRIPTION A.P. #027-070-021 All that certain real property situate in the County of Butte, State of California, described as follows: A PORTION OF LOT 3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "ADDITION TO SUBDIVISION OF THE PALERMO CITRUS TRACT", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 23, 1888, DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 3 IN BLOCK 117, WHICH POINT IS IDENTICAL WITH THE CENTERLINE INTERSECTION OF MAPLE AND CITRUS AVENUES; THENCE SOUTH 88 DEG. 26EAST, 413.90 FEET TO AN IRON PIN IN THE CENTER OF THE OROVILLE-WYANDOTTE IRRIGATION DISTRICT CANAL; THENCE SOUTH 20 DEG. 56EAST, 259 FEET ALONG AFORESAID CANAL TO A POINT ON THE WEST BERM OF THE CANAL, SAID POINT BEING MARKED BY AN IRON STAKE AND R.E. TAG NO. 2435; THENCE NORTH 88 DEG. 26' WEST, 7.83 FEET TO AN IRON PIN; THENCE SOUTH 22 DEG. 19' EAST, 459.7 FEET TO A POINT ON THE LOT LINE BETWEEN LOTS 2 AND 3 OF BLOCK 117 OF PALERMO CITRUS TRACT; THENCE NORTH 88 DEG. 26WEST, 673.6 FEET TO A POINT IN THE CENTERLINE OF CITRUS AVENUE TO THE POINT OF BEGINNING. EXCEPTING THEREFROM ALL THAT PORTION OF THE SOUTHWEST QUARTER OF LOT 3 IN BLOCK 117, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "ADDITION TO SUBDIVISION OF THE PALERMO CITRUS TRACT", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 23, 1888, DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 3 IN BLOCK 117 AT THE CENTERLINE INTERSECTION OF MAPLE AND CITRUS AVENUES; THENCE SOUTH ALONG THE CENTERLINE OF CITRUS AVENUE, A DISTANCE OF 369.00 FEET TO THE TRUE POINT OF BEGINNING; THENCE FROM SAID TRUE POINT OF BEGINNING, PARALLEL TO THE NORTH LINE OF SAID LOT 3, SOUTH 88 DEG. 26' EAST, A DISTANCE OF 249.00 FEET; THENCE SOUTH A DISTANCE OF 119.00 FEET; THENCE PARALLEL TO THE NORTH LINE OF SAID LOT 3, NORTH 88 DEG. 26WEST, A DISTANCE OF 249.00 FEET TO A POINT ON THE CENTERLINE OF CITRUS AVENUE, A DISTANCE OF 119.00 FEET TO THE TRUE POINT OF BEGINNING. CDF FIRE SAFE REQUIREMENTS �7 -0 . AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made apart of this permit. These requirements are minimums and will, be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building- Department for compliance. [ 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual.maintenance must be provide for by the land owner. Driveway Standards [�Q 1273.02 Surface. All driveway surfaces and structures (bridges, 1273 .07 culverts and other app-arteaant structures which supple- ment the roadway bed cr shoulders) shall. provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds.. jx] 1273.03 Grade. Not to exceed 16 percent unless paved 1273.04 Driveway Radius [ 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [xj .2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. 1 [�Q 1273.05 :Turnarounds. If required, will have'a minimum turning radius of 40 feet from the center of the road. 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 11 feet long with a minimum 25 foot taper'on each end. [�] 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. du f t �- WUV 1 'c , Page ' 1 of 3.. allILDiNG DEPARTP 6N1 P Roy D V, 1. • • . • • - , 0 .-Z`I - ZaSZ 50R " AP # PERMIT # NAME [ 1273.10 Turnouts. Driveways' exceeding..150,feet in length, but less than 800 feet in,length, shall provide -a turnout near the midpoint `of -the driveway. Where a driveway exceeds. 800 feet, turnouts.shall be provided no more than '400 feet_ apart . - (�1 1273.10 Turnaround. A turnaround' hall -be provided'at all ` . building-sites'on driveways over'300 feet in•length and shall be within 50 feet,of`the building. 1273.11 Gates , '1: -'Gate -entrances shall be at least'. two feet wider than the roadway 'it serves. r 2. The gates -must ,be located at least 30 feet from the roadway and,- 'shall open to allow a vehicle to stop :without'obstructing traffic on that roadway. [ ] 3. Where a. one-way road with a single traffic lane -provides entrance, a 50, foot -turning radius shall be. used Fuel' Modification .1276.`01 Setback for Structure Defensible Space. 1. 'All parcels 1 acre.'aud larger'.shall provide a -mini°•- - mum 30 foot setback , for buildings, and. accessory buildings from ul] . groperty lines •and/or, the ,center of the, road . ( j 2. -For parcels less than f acre., local jurisdiction ' shall, -provide for the same -practical -effect." See Other Requirements below. ' 12 76..02 Disposal ,of. Vegetation and Fuels.. Disposal, including -chipping, burying, burning or removal -to a landfill site ' approved 'by the local jurisdiction, -6f 'flammable ".vegetation ..and' *fuels caused by site development and construction, road and'driveway construction and, fuel • modificatior. shall ba completed_prior to completion of road construction )r fi_ial inspection 'of; a.• building permit; Page 2 o f 3 R M.H.L OR -11AW 12W! • ...?t;.rp:a>:4. ..2.. Oi/'0�4ffiJ..ii.R:>J:;,........... ......,....... �:.,..,aCdJ.... ....�.$.,.:: t 1• .Owner's Name: r m 2. -Assess'or's Parcel Number: 0771 f�r 3. Installer's Nanic-iL -j7 4.---Is'the site currently•under permit? Yes[ (.] ' No[ � •]' Permit No. Plens) off'] Yes, furnish two lot5. Is the site an existinsite? YesV]`Id 6. What is the electrical :rating of the mobilehome? 10O Amperes. 1. What is the=mobilehome site circuit breaker rating? 8aD � 'Amperes. 8. What is the electrical rating of the mobilehome site? am Amperes. 9. Is the main service remote from the mobilehome site? Yes[ ] No[ ] If it is, what is the rating? Amperes. 10. Is there. any other electric load to be served by theinobilehome site electric service (i.e. well, garage etc.)? Yes[ ] No[ J If yes, please identify the load and size: a).. The mobile home site: ' Load- Amperes - b) The'main service: Load- Amperes- . 1.1:. Type of gas service at rnobilehome site: Natural[ ] Propane[ y] None[ ] . 12. Size of gas pipe at the mobilehome " site from- the - meter or tank: 3)4. inches. :> 13. What is the gas pipe length from the meter or tank to the mobilehome? . _. (ft.). 14.. What is the mobilehome gas demand? B.T.U.* f u *(This information is not 'required if the pipe length 'is less than 6 feet on natural gas or less than 50 feet on propane). b THE OTHER SIDE OF THIS FORM MUST BE -COMPLETED IN ORDER TO PROCESS THIS PERMIT APPLICATION Mobilehome Manufacturer: CHAMPION = Manufacture Year: If other than single wide; furnish Setup Model Number: 741 Width: 26 (ft.) Length: 66 ft.) Tagalong or Expando Size (ft-) x_(ft-) ,,On all mobilehomes manufactured after October 7,- 1973, furnish manufacturer's installation manual and structural setup Sheets.' FOOTINGS: , Wood pressure treated or foundation grade[x Other - SUPPORTS: Concrete block[x Other: Provide Tic Down Specifications for all Mobileho-mes:'-u-oc---�laf,(A Pier Footings Sizes and Location SINGLE WIDE MULTI -WIDE Line 1 4 1 ine I Line 2Line 2 ................................................................................................ ......I............M..a..n....e.a.= LL- 2 ... .......................................... C 2 Line 1 Line 3 Line 2 Main Bcanu .......................................................... Line 2 Line I ...................... -------------- ...... I c5 Tag or Triple c 4 ............................................ 4 ine I Line 1' Piers; Line I Openings Size minimum: x Size rru*nimum'. x Spacing maximum: f Each side of openings From ends-makimuml with width over: L Line 2 Piers: Line 4 Piers: Size minimum: 24 x [30 Size minimum: x 'Spacing Maximum: Spacing maximum: From ends-maximumt_2 0 From ends -maximum. Line 3 Roof Loads: Size minimum Location (from W): 24x30 12x30 0 OVER a FOR ALL OTHER IMFORMIATION" SEE CHAMPION HOMES SET=IJP 1) 20P5F ROOF LOAD 1) 30'PSF ROOF LOAD ` MANUAL. 2)1000 PSF SOIL 2)1000 PSF SOIL TYP.3) V-011' OG SPACING MAX. 3) V-0° O.G. SPACING MAX. - E, 20OX 20OX 6II FOOTING SINGLE BLOCK 4) 24 WIDE--187 IS X 5FOOTING -4) 24 WIDE--20 X 20 Xb FOOTiNW 4 - 26 WIDE--I3 X 19 X 61 FOOTING 26 WIDE--21 X 21 X 6y.FOOTING o nP 14128 WIDE--2011X 20"X b' FOOTING' 1488 WIDE--21"X' 2I°X b' FOOTING 36"X 3(6'X, 10' FOOTING DOUBLE BLOCK 16/32 WIDE--2011X 20'X b" FOOTING 16/32 WIDE--2211X 1211X11' FOOTING I� 4 f XTEMOR DOOR LOCATION 1-4 ----------------=---------------- ----------------------------------=-------------------- ------ - 1 LLJ III-So El E3 E3 MARRIAGE3 E LINE � 1 :hCY•+Y, El ` m 40 W. RIDGEBEAM SUPPORTS CC U - ' 1 .. -- --- —CCC// -------------------------------------F—r----------------------------------------------------------'--'—I B� L EXTERIOR DOOR LOCATION .'V �O�CA11p� AT`-i:�, ��.� ' gym .. _jam I� � (� (� (� 26'X �JU11L=�WJUPOCH ll DOME MU LSDERS QD. .. •�ew en - I/4 ODR9 - ... (�jL1� J� �j� jam. HOME •10 -z. TOI tNtwiM YY DRV[ SUITE 5". IaKM VILLA I'9. 4&H6 wn.f-�I•yt - Table 4.3: Marriage Wall / Sidewall Opening Pier Loads (Ibs) Home Width (ft) Clear Span opening in marriage wall (ft) 20 Design Roof Load 30 40 (pso 60 80 24 double •4'-1" to 8 1700 2300 2900 8000 10300 8'-1" to 12 2600 3400 4300 . 10000 12900 12'-1" to 16 3400 4600 5700 12000 15500 16'-1" to 20 4300 5700 7200 14000 - 20'-1" ,to 24 5200 6900 .8600 - 26 double 41-1"Jo 8 11900 2500 3100 8800 11300 8'-1" ao..12 , , 2800 .. 3800 4700. 11000 14100 .3800. 5000 6390 13200 16900 .4700 6300 7800 15400 20'-1" ;.to .24 6600' 7500.. 9400 - - 28 double 4'-1 "-; to_8 '1900 2600 3200--;.— 9000. 11500 8'-1"'to 12 , 2900 .3800 4800 11200 :14400 12'-1" to 16 3800 5100 6400 13400 17300 16'-1" to 20 4800 6400 8000 15700 - 20'-1" 'to 24 5800 7700 9600 - - 32 double 4'-1" to.8 8'-1" to 12 12'-1" to 16 16'-1" to 20 __`1M 2900 3800 4800 2600 3800 5100 6400 3200 4800 6400 8000 Sidewall opening pier capacity is 1/2 the load shown above. ouIILC.UUNII *J. ILD4NG DEPARTM6W hppROVED 4,f— 17uIN" !P!Onl HOME SUR-DEA! �/ 17 a • � _ � ��� � BAR (amu �fi�"�R�� � �' N 41 - D yF�NPfzOVtu - - C) BFOROGf1 1i OPT: a �. Butte County _ ` I� o x u'•J FAMILY ROOM Environmental Health � o -- Date Signature - J , 1 �.. M1LY DINING OM °•a'x-u'a• ' KITCHEN - - o 1 d I WH 12'•4' • - .. • 1 AVE, 11.fM rurtmr 1 ' MASTER BEDROOM �� 0 BEDROOM 12 ® BEDROOM '3 L IvINCs ROOM Ib .m- x Ir'-:" n • 0 x 17. y. II'•Pr" X 17. 4. 11'.Qi• X Q'- J. Iv a�IT _ Q• 3 BEDROOM MODEL 141 16'•X 66' 1116 SO.'FT. M5 09-14176.10 314 eEDFROC41 ca� -f? o • rca;e.lia.l-o _ '�-' PATE LITERAT11kE PLAN -. 840 Pi.Lli AVE.; LINDSAY, CA 93247 - - Temp. Powe, Pole Called P.G&E Temp. Elec. Serv.' Called PG&E Temp. Gas Serv. Called PG MAILED (Date). S Signat ignat COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS (NOTE: An entry must be made on this form each time you vi alt the job site.) BUILDING INSPECTION RECORD `: , BUILDING BUILDING (Cont'd) I PLUMBING Setback Firewall f Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall 'Sidin To out Slab Roof Sheathin i Water Piping Piers Roofing Z % Sewer Garage Fdn. Vents Z0 Fixtures Footings Stemwall Garage Vents r""—"-- Insulation 3 Z Water Htr. Heaters Slab Carport Footings Prov. forph s ally handica ed Conformance of ex. re _ A liances Gas Piping & Test j Temp. Gas Slab Ffinaij V-,-5 3 2 1 Sanitation Patio FIRE E Final Footings Footing ELECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Z Bond BenFIRE SPRIN RS Motors Framing Test Water Htr. -------- Stucco Stucco Final Subpanels )' Z d Mesh MECHANI AL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Zmanent Door Closer Final ma MOBILEHOME UTILITIES Elec. Serviceec. Pedestal Water Piping Sewer Gas Piping N21316EHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping ' DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you vi alt the job site.) COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Driy? — Groville, California 95965 �. Tel ephont;: 534-4541 APPLICATION AND PERMIT uM7��-�9 authorize representatives of the Oounty of Butte to enter upon the above-mentioned property for inspection purposes. A X 4z� Date 7 Signature of Permitee or Agent Receipt No. 0,-Q J White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DDIIRECTOR PUBLIC WORKS BY`YDater? F %% BdIding permit expires Date P_%41?0 BUILDING Owner SQ. FT. OCC. BUILDING VALUATION 349LO _X oo, Mailing Addresszo ax Telephone No. Contractor Mailing Address Fireplace Total Valuation Telephone No. Permit Fee Building AddressPlan Checking Fee&/or Penalty Permit Fee Q " Ge �' //rte, PLUMBING No. @ FEE PERMIT FILING FEE $3.00,DC7 Each Trap 1.50 Repair drainage or vent piping 1.50 A. P. No. "Zoning & Planning Water piping 1.50 Each gas water heater or vent 1.50 Ftee W4'r Salt on Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA ParkingParcel Plans Declaration Parcel Map 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 Bldg. P s Rec'd � ParcSrovol Plans Approval Lawn sprinkler system 2.00 NEW fa ADDITION ❑ UTILITIES ❑ OTHER ❑ Permit Fee • $ ��� $ - L ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 ,0K) Main service 100 AMP ORV OR SL=SS 5.00 Single Family ❑ Duplex ❑ Mobil Home 1g Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER 600v 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW CONST OR ADDNS. ACG. I CUP 4) 2¢Sgft AIZ CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW CONSTR M L CH CII T NON.CONS � BRANCH CIRCUITS) 12.50ea NEW CONSTR (POWER APPARATUS.5, NON-RESID. SINGLE OUTLET CIR. Ex. Occur)(OUTLETS OR FIXTIIRES g L1@ 00 FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 1 am exempt from the Contractors License Laws of the State of California. Permit Fee $ p $ WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. ®I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT T FEE $ t authorize representatives of the Oounty of Butte to enter upon the above-mentioned property for inspection purposes. A X 4z� Date 7 Signature of Permitee or Agent Receipt No. 0,-Q J White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DDIIRECTOR PUBLIC WORKS BY`YDater? F %% BdIding permit expires Date P_%41?0 RESIDENTIAL ENERGY CONSERVATION STANDARDS `CONSTRUCTION COMPLIANCE CERTIFICATE THIS IS TO CERTIFY, THAT ENERGY CONSERVATION REQUIREMENTS HAVE BEEN INSTALLED IN CONFOnCE WITH CURRENT ENERGY CONSERVATION REGULATIONS AT Z 6 . (location)/ v BUILDING PERMIT NO. G % "7G% A;P. N0. THE FOLLOWING HAVE BEEN INSTALLED AS PER APPROVED PLANS: (Check each item or write N/A if not applicable) INSULATION: GLAZING: Slab Edge. Single Glazed Fdn. Walls Special (Insulated) Floors CERT. & LABELED WDS. Walls — c & SLIDING DRS. Ceiling/Roof WEATHERSTRIPPED DRS. Ducts BACK DAMPERED FANS Circulating Pipes -- INTERMITTENT IGNITION DEVICES APPROVED HEATER CERT. APPLIANCES " APPROVED WTR.HTR. I DECLARE THAT ALL REQUIRED ITEMS AS NOTED ABOVE HAVE BEEN INSTALLED IN ACCORDANCE WITH THE ENERGY CONSERVATION REQUIREMENTS AND AGREE TO. THE COMPLETENESS OF THIS CERTIFICATE AS SUBMITTED. ' Insulation Applicator -.Name Signature of (please print) Insulation Applicator State Contractors License No. ✓/ , General Contractor/Owner Name - L 21' ®7L (please print) Signature of . .3 -L, / a General Contractor/Owner / 7� State Contractors License, No. • C r THIS CERTIFICATE MUST BE ON F ILE W ITH THE BU ILD ING DEPARTMENT PRIOR TO REQUESTING FINAL INSPECTION'AND SHALL BE POSTED IN A CONSPICUOUS LOCATION WITHIN THE DWELLING'. COUNTY OF BUTTE ; gEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of the California Administrative Code, Title 25, Chapter -5, under permit number 4 for the following location: �/1— f9f P Owner's Address'! Mobilehome Mfg. 4�."S4, 4"" Model Year,/16-9 Insignia No. `7 i-3 Serial No. efe/9 It is hereby certified for occupancy at the above described location and may be occupied. r Director of Public Works Date '/ ��By rW THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED Aw ---. Lamin Test Water Htr. Stucco Final 4 Subpanels Mesh MEC ICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish X Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UT LIT! S --- Elec. Service Elec. Pedestal Water PipingSewer 3 i Gas Piping MOBIJ—EHOMEINSTALLATI N ------------- Support 4 4 Elec. Continuity 44 Z 44 - Water Piping Drainage Gas Piping DAT REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDIM, BUILDING (Cont'd) PLUMBING Setback Firewall / Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall ! Siding To out Slab Roof Sheathing Water PI in Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Stemwa I I Garage Vents A Insulation Water Htr. Heaters Slab Carport Footings Prov. for phsically handicapped Conformance of ex. structure Appliances Gas Piping& Temp. Gas st Slab Final74��Sanitation Patio SP Ile FIREPLACE Final Footings Footing E •ECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE. PRIN ERS Motors ---. Lamin Test Water Htr. Stucco Final 4 Subpanels Mesh MEC ICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish X Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UT LIT! S --- Elec. Service Elec. Pedestal Water PipingSewer 3 i Gas Piping MOBIJ—EHOMEINSTALLATI N ------------- Support 4 4 Elec. Continuity 44 Z 44 - Water Piping Drainage Gas Piping DAT REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE. DEPARTMENT OF PUBLIC WORKS 7 County Center Drive — Oroville, California 95965 j Telephone: 534-4541 - APPLICATION AND PERMIT -- - — y vi uu uc av GUaG, UIJVII UIC above-mentioned property for inspection purposes. X Y&ATl0� - ate1 Z& 7� Signature of Permitee or Agent of/ R e c e i pt No. ��/ (y —21 9S White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work in atQdd above for which fees have been paid. DIRECTOR PUBLIC WORKS BY Date /—/— 7E B 'ding permit expires Date q , 7,� BUILDING OwnerBa D SQ. FT. OCC. BUILDING VALUATION Mailing Address O v ( le- Telephone No. Fireplace Contractor Total Valuation Mailing Address Permit Fee Plan Checking Fee&/or Penalty Telephone No. Permit Fee Building Address �"" PLUMBING No. @ FEE PERMIT FILING FEE $3.00 IE Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 r 9112A%n9 3ffirificalion Qnl Each gas water heater or vent 1.50 A. P. No. �� rQ �Zo 41Gas piping system 1 - 5 outlets- 1.50 OOJO. Each additional outlet .30 qad's'T4-�Cl. a Fire Dept. Fire Zone Use _Permit Building sewer 5.00 1 U EQA Parking Plans Parcel Declaration Parcel Ma 60' R/W Im rove ents P Lawn sprinkler system 2.00 Bldg 1R Parcel A roval Plans Approval Permit Fee $ 3 NEW ❑ ADDITION ❑ UTILITIES OTHER [�]' ELECTRICAL No. @ FEE PERMIT FILING FEE $3.003,00 M"Ud- � n 1 Main service 100AOR MP OR 00 SLESS 5.00 f)'D Main service EA. ADD'L 100 AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home Others ❑ OVER 600V Main service 00 AMP OR LESS 25.00 Main service EA. ADD'L 100 AMP 1.00 r � it�' 500 SQ. F 1. MIN, ,UM NEW CONST. DWELLING OCCUP. & OR ADDNS. (ACC. eLDGs. ) 2�sg ft NEW RESID. BRANCH TLET CIRCUITS) NON-RESID,CO N ST BRANCH CIRCUITS) '2.50ea �J/� FOR MOBILE NEW CONSTR. //POWER APPARATUS & NON-RESID, lS LE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the .provisions of Chapter 9,' Div. 3, of the State of California Business & Professions Code under. the name style of: OD Ex. Occup(OUTLETS OR FIXTURES) @2514tOC Ex. Occu FIXED APP LNS. OR P. ( OUTLETS (RESID,) EA) 2.00. Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 El I am exempt from the Contractors License Laws of the State of California. Permit Fee $ D7.0 $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the.provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No.1 @ I FEEPERMIT FILING FEE J$3.00 Heating Cooling Ventilation Hood 2.0071— Permit Fee $ $ 1 certify that I have read this application and state that the above� information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Q TOTAL PERMIT E -- - — y vi uu uc av GUaG, UIJVII UIC above-mentioned property for inspection purposes. X Y&ATl0� - ate1 Z& 7� Signature of Permitee or Agent of/ R e c e i pt No. ��/ (y —21 9S White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work in atQdd above for which fees have been paid. DIRECTOR PUBLIC WORKS BY Date /—/— 7E B 'ding permit expires Date q , 7,� COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS - 7 County Center Drive — OroviIIe, California 95965 Telephone: 534-,4541 APPLICATION AND PERMIT author: BUILDING Owner 13 S SQ. FT. OCC. BUILDING VALUATION Mailing Address a LMa 1e Telepl-yp�le No. ?j dC/ Fireplace Contractor (2 Jef Total Valuation Mailing Address Permit Fee Plan Checking Fee &/orPenalty Telephone No. Permit Fee Building Address i PLUMBING No. @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. -Q r-� Zoning 8 Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F s WCl -Fire Dept. FireZone Use Permit Building sewer 5.00 EQA Parking Plans ParcelParcel Declaration Ma p 60' R/W Improvements Lawn sprinkler system 2.00 Bldg. Plans Recd IT Parcel A$rTl�voI I Plans pproval Permit Fee $ NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ® ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 —17-676q Main service 100 AMP OR600V OR LSLESS 5.00 Main service EA. ADD'L 100 AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home ❑ Others ❑ OVER Main service 1100 AMP OR LESS 25.00 Main service 'EA. ADD•L 100 AMP 1.00 NEW CONST. DWELLING OCCUR. & OR ADDNS. ACC. BLDGS. ) 20sgft NEW CONSTR. MULTI -OUTLET NON-RESID. BRANCH CIRCUITS) '2.50ea - NEW CONSTR, POWER APPARATUS & NON•RESID. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Ex. Occup(OUTLETS OR FIXTURES)N'25Q BAL @104 Ex. Occu FIXED APP LNS, OR P•(OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit' Fee WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. 09 I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby 36 -- OTAL PERMIT FEE $ -" ze representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. X �7Glfi7 l Signature of Peerrmiteeror Agent Receipt No. White-D.P.W. — yellow-Assessor,2Pink-Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above r which fees have been paid. REC AWR OF PIJBLIC WORKS � ^ ■ MOBILEHOME INSTALLATION INSPECTION CHECK LIST 1. Is the mobilehome located wi required separation from lot lines and buildings and generally conform to plot plan? Yeses( No 2. Does the mobilehome have required clearances above ground? (Sec.5085) Yee No. 3. Are footings and supports properly sized, spaced, and bracedas er approved plans? (Note possible variation at spring.shackles.) (Sec. 5082 & 5683) Yes No .4. Is the mobilehome level? (Sec. 5088)4Yes No 5. I e. an a s are crossover .con-nec-tions properly installed? (Sec. 5088) Yes No 6. Water A. Is flexible connector of adequate size and properly installed (1/2" ID min..)? (Sec. 5566) Yeses` No B. Test - Does water piping withstand working -pressure -or 50 lbs. air test? Yes No C.: Ba coac -approved, does station have backflow device and pressure -relief valve? Yes No f 7. Wastes and Drains \ n A. Is connection made with Schedule 40 DWV and have flex connectors at''each end? Yes No B. Does it have minimum" per foot slope and is it properly supported? Yes No C. Are -any leaks detected in -drainage system after running 1j -gallons of water through each fixture including washing machine standpipe? Yes_ No ;�(' D. c is not Sta e o d s -station have required trap and vent? Yes No ' 8. Gas Piping and,Gas.Vents A. Connector - Is mobilehome connected to the gas supply with an approved 3/4" minimum mobilehome connector not more than 6 ft. long? Note: 'All piping is.to be at least as large as the mob'1 home gas line inlet without reductions other than•the mobilehome connector,. Yes No B. Test OK as per following procedure? YesNo 1.' Open all appliance connector valves 2. Shut off appliance burner and pilot valves. 3. Air test with.'manometer to 10"-14" water column, or test with slope gauge (minimum 6oz.-maximum 8 oz.) calibrated in tenth pound increments. Test for 10 min. without drop. 4. Connect gas meter to mobilehome with connector, turn on gas,' test connections' with soapy water. C. Are all appliance vents properly installed? Yes No.' 9. Electrical• A. Is service large enough to provide adequate amperage -to mobilehome (must equal rating of mobilehome with a minimum of 100 amp)"and other facilities on lot, i.e., water pumps, garage, cabana, etc.? Yes V-74C No t B. Is there proper clearances around panels? Yes X, No C. Is power supply cord,or feeder assembly properly fused? Yesx- No D. Is continuity test satisfactory as per the following procedure? YesV No 1. De -energize electrical wiring system of the mobilehome at the pe estal. 2. Make sure that the power' supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. 3. Switch all breakers and switches in the mobilehome to the "on" position. 4. Connect one lead of a test instrument to the mobilehome grounding conductor and apply the other lead to each mobilehome supply conductor, including neutral. 5. All non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. 6. Upon completion of the above procedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the mobilehome. Upon satisfactory completion of the electrical tests, the lot or site service equipment may be approved for energizing. 10. Is job card signed by Health Department for water and sanitation? 11. If everything okay, sign off card and tag services. MOBILEHOME DATA _ Manufacturer and/or Namestylel�- Length y Width / Vehicle Serial No. State Identification No. Additional Information'or.Comments: MOBILEHOME SUPPORT DATA •Il°other than single wide, 644 elt) C furnish Setup Model No. Year. SAF Mobilehome Mfr. ---- 6cla Width. (ft.) Box Length{ft) Tagalong or Expando Size ft. x G ---ft: (SHOW SUPPORT DETAILS BELOW).-_,,., - On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation manual and structural setup sheets (if not on file with the County of Butte). All center -supports measured from front of, mobilehome unless otherwise specified. (-A Footings (check one) .. Single M�": 1..Wood either pressure treated or y foundation.gride. P (ft.)(in:) n.) (in.) 2lthen specify) ► Sa 3' F . Center support Center support locations* footing sizes Supports (check one) (in.) 1: Concrete block. 2, Other (specify) (ft.) .). (in.) (in.). ' Tagalong or Expando, show support details. ; A " x --.Typical ,Support (in:) (in.) Footing Size (ft.)(in.) 'n.) (in.) Q -- Max. Pier Spacing -- Max: Overhang xv „(ft.)I (in.) (in.) (in.) 1 (ft.)(in.) BUTTE COUN I Y ,F BUILDING DEPARTM.EN APPROVED *If center piers are other than drawn above, draw in—locations, spacing, and dimensions. BUTTE,COUNTY.DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, OroviLle, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 1. Owner's name: 13 6 ID s (311 2. Installer's name: 3. Is the site currently under permit? Yes / ''/ No (If yes,, furnish permit number OR Is the site an existing site? Yes / / No / (If yes, furnish two (2)'plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes No (If no, clarify 5. What is the mobilehouie electrical rating? --------------- ------- Amps 6. What is the mobilehome site service rating? ------------- - ----- Cr'fl Amps wt -4 7. What is the mobilehome site circuit breaker rating? ------ --- �" l 8. Is there any other electric load to be served by the mobile site service? --------------------------------------------------- Yes No / / 60'a a �a (If yes, identify the load, and size: i/l k (Loa'3) (APs) 9. What is the mobilehome site,gas-pipe size? ---------------------- 10. What is the type of gas service? ----------------------------- Natural / / LPG 11. What is the gas pipe length from meter or tank to the mobi (ft.) 12. What is the mobilehome gas demand? ------------------------------ (BTU) (This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) PERMIT NO. 303'0-77B,P,E _ S PERMIT EXPIRES OWNER Bob, Pearson CONTR. owner 27-07-21 LOCATION (A.P. S/S Maple Ave.,app.280'E.of Citrus Ave., r Palermo 1 Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Gas Serv. Called PG&E ""` /Temp. OB FINALED U (Date) (Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING I BUILDING (Cont'd) PLUMBING Setback 44 Forms Main Bldg. Footings Stemwall Slab / Piers Garage Footings -7V Stemwall —� Slab Carport Footings / Slab Patio Footinas / Firewall Restroom Finish Windows Siding Roof Sheathing -� Roofing Fdn. Vents Garage Vents Insulation Provfor physically i handcapped Conformance of ex. structure Footin FIREPLACE Soil Piping c 1st Floor 2nd Floor t 3rd Floor To out Water Piping Sewer Fixtures Water Htr. Heaters— Appliances eatersA llances Gas Piping & Test Temp. Gas Sanitation Final ELECTR Reinf. Steel / Final \ Fixtures Bond Beam FIRE SPRINKLERS Motors Y Framing -" Y:-7 � % X/! L v COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS, ~� 7 County Center Drive �. Oroville, California 95965 Tele hone: 534-4541 _ APPLICATION ANDITERMIT 0, auuIUllce IeNresenlauVes UI lne L,ounty ul twtte to enter upon the above-mentioned property for inspection purposes. Signature 'of Permitee or Agent Receipt No. 9-2 //o White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF BLIC WORKS By Date �'I,?' 7 7 Bui(dlng permit expires Date '6�`-L,p, 7,r BUILDING Owner 13A Beq rS Oi SQ. FT. OCC. BUILDING VALUATION , - --,7 . Mai I ing AdIress / p 3 r• Telephone No. - az Fireplace Contractor tin Total Valuation 'er Mailing AddressPermit Fee Plan Checking Fee &/or Penalty Telephone No. - Permit Fee Building Address ��� PLUMBING No. @ FEE PERMIT FILING FEE $3.00 ,p'p R—d Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 $O Each gas water heater or vent 1.50 i � A. P. No. /-.� Zoning & Planning Gas piping system 1 - 5 outlets 1.5 Each additional outlet 30 Fees. W. i tion Fire Dept. FireZone. Use Permit Building,sewer 5.00 EQA I Parkin Plans are Declaration Parcel Ma p 60' /W Im rovem nts p Lawn sprinkler system 2.00 Bldg. Plans Rec'd Parcel Approval Planst4roprovol Permit Fee $ $ NEW ® ADDITION ❑ UTILITIES ❑ OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 160.0 Main service 6001 OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD'L 100 AMP 2.50 Main service OVER 600V 25.00 100 AMP OR LESS Single Family ❑ Duplex ❑ Mobil Home ❑ Others Main service EA, ADD'L 100 AMP 1.00 �II e GR NEW CONST. DWELLING O OR ADDNS. ( ACC. BLDGS. 20 sq ft NEW CONSTR. (MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS) 2.50ea NEW CONSTR. POWER APPARATUS & - NON.RESID. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: 50 e25e Ex. Occup(OUTLETS OR FIXTURES) SAL@109 FIXED APP LNS, OR Ex. Occup. (OUTLETS (RESID,) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 ` License No: Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ d $ - MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this r" permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 Heating . Cooling Ventilation Hood 1 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances - and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ auuIUllce IeNresenlauVes UI lne L,ounty ul twtte to enter upon the above-mentioned property for inspection purposes. Signature 'of Permitee or Agent Receipt No. 9-2 //o White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF BLIC WORKS By Date �'I,?' 7 7 Bui(dlng permit expires Date '6�`-L,p, 7,r vac /-i'7 NOTES t. RESIDENTIAL 027-07 PERMIT NO. i_ 00-1938 SORL4 'kERASMO 4 t 2460 MAPLE AVENUE, OROVELLE CONTR: OWNER DECK SPECIAL CONDITIONS, CHECKED BY -- SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ.. T SPECIAL INSPECTION ITEMS ( VERIFY USE PERMIT CONDITIONS { SUB -STANDARD HOUSING LETTER r � , JOB FINALED (Date) Signature = OK 0 = Not OK - =•Not Applicable * = Not Ready: MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. 2. Soils; Special MH Support Sketch Gas; MH Test -Demand -Valve -Connector 3. Sewer;. Location -Test -Fall -C/O -Concrete 5. 4. Water; Location -Test -Easement Needed (Sketch) Water; MH Test -Regulator -Connector 5. Electricity; Location- Clearances-Grnd-/ /Amp -Concrete 8. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / • P Nat. or / /"L"ft./ PLPG 7. Well Clearance & Discohnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ' MISCELLANEOUS r Date DECKS, COVERS, AR ORTS GARAGES (Plans) OK except #'s n equirements-Setbacks-Easements otings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails Wood Awn.; Posts-Beams-Rfirs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frma.: Sills-Anchors-Studs-Rttrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels k Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s d 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. x Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Pane lboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche t Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 V= OK 0 = Not OK - = Not Applicable = Not Ready RESIDENTIAL (Single & Duplex) Date Underfloor (Plans) OK except #'s Slab, Steel -Wrapped Date FRAMING (Continued) 1. Zoning -Setbacks -Easements -Flood -Slope 9. 46. Hangers -Post Caps -Anchors -Connectors 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 47. Cling. Joist-Rftr. Ties- Purlin-Rolf Brac.-Truss-Shting.-Rfng. 3. Fig., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Electric Underground 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 14. 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Stemwalls, Main; Steel-Blockouts-Wrapped 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 51. Garage Fire Protection Framing 6a. Hold Downs and Special Anchors 52. Property Line Firewall & Openings 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 69. Stairs & Rails Date 70. Card B-1 Date Card B-1 Date 71. Card B-1 Date Card B-1 Date 72. ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or AI Insulated Neutral Q Yes ❑ No 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector 84. A.C. Unit Disconnect, Electrical -Plumbing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Water Well, Disconnect, Electrical, Plumbing MECHANICAL (Permit) OK except #'s 87. 35. A.C. Ducts Insulation & Support 88. 36. Vent Fan, Exhaust above insulation 89. 37. Condensate Drain & Overflow, Size & Grade 90. 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 91. 39. Attic Access & Platform if Furnace in Attic 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Date FRAMING (Permit) OK except #'s Card B-1 Date Card B-1 40. Sits Proper Materials & Anchors Card B-1 Date Card B-1 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound Card B-1 Date Card B-1 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Wal Is -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 82. Following Instld./Drive J Yes :1 No/Walks _1 Yes J No/Planters J Yes 'J No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: -COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PER IT NO. (Rev. 12/96) APPLICATION AND PERMIT X ���3F ASSESSOR PARCEL NUMBER 027-07-0-021 ZONING AR 22 BUILDING PERMIT OWNER SORIA, ERASMO TELEPHONE 533-5705 SO. FT. OCC. BUILDING VALUATION 420 OWNER'S MAILING ADDRESS 2460 MAPLE AVENUE, PALERMO 95968 CONTRACTORS NAME OWNER TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDERS MAIUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Fllin Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS 2460 MAPLE AVENUE, OROVILLE Energy Plan Checking Fee $ $ PERMIT FEE $ LAT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: DECK Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service 2o0A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class LIC. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service TO , 46.00 WEU.200A NEW CONST. DWEWNG OCCUP. U ADONS. ( 8 ACC. SO 3.5,s NEW CONST.OR OUTLET NON -RES D. MULTI -OUTLET CIRCUITS 97.50 POWER APPARATUS a SINGLE OUTLET CIR. EX. OCCLI , OUTLET OR FLXTURES 20 BAL Q ,.SO Ex. Occup. oFtrrEiEis R LNS p.OEA. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. 1. / X�na�;oko�iican't DVt(e " 0 S - ❑ O er ❑Contractor An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOT L FEE $ 109.10 HAZ. D. FEES IMP _— FLOOD r_ CDF PAR PQi D� ISsu This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By�Qate. PERMIT EXPIRES ON I the applicable provisions Resolutions to do work been"paid. ,® Ip ReceiptNo. 302535 $109.:10 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT 11 - 31 R9 ASSESSORPARCELNUM ERZ°" ° 1 , a BUILDING PERMIT OWNER 2c&id' TELEPHONE '533-15705 SO. FT. OCC. BUILDING VALUATION . OWNERS MAILING ADDRESS p f nn ry1 W CONTRACTORS NAME ^- n^ •� i TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ r 00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ $ PERMIT FEE $ CID LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehomek Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel O Utilities ❑ Installation0 Other ❑ Describe Work: 00-19138 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 800VLE Main Service 2a 0A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. No. OWNER -BUILDER DECLARATION { I hereby affirm under penalty of perjury that I am exe pt from the Contractors License ot I, as owner of the property, or my employees with (sages as their sole compensation, rOw.for the following reason: will do the work, and the structure is not inter/ded or offered for sale. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. / ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service TO 46.00 W:L200A CCU000A NEW CONST. DWELLING OCCUP. OR ADDNS. s ACC. Bins. S° 3.5¢FT. N .c.o,.T. MULTI-OUTLEITST @7.50 APPARATUS d SINGLE OUTLET CIR. Ex. OCCu OUTLET OR FIXTURES j 20 SAL Q 1.50 FIXED APPtNS. OR Ex. Occup. ourLErs RESID. EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 reby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permitis issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. G ,� VX �)(� �/, Date Z— �" _ gnature of Applicant - ❑Owner ❑ Contracto � I A ant An OSHA permit is required for excavations over So" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST. TYPE TOTAL FEE $ �7. 00 HAZ. D. FE IMP FLOOD CDF PARCEL PD NO ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicate above for which fees have been paid. A, w /i /► /3%off �i® By ���=XX Date 16) PERMIT EXPIRES ON q///o ate ReceiptNo.2>32 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE, - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION '' 7 COONTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 /PERMIT APPLICATION DATA SHEET % OWNER: / ASSESSOR PAR NUMBER: 4;? 7ri� Proposed Building Use: Building Inspecto} Date: "Yf At time of permit application, I was advised the following data m s e submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted. Plot plans, 3/4 sets, signed by the preparer of plans. ------ 3. Complete plans, 3/4 sets, signed by the preparer of plans. 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ ❑ 6. Energy Design Compliance and supporting documentation. ---------------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. --------------------------------------------------------- ❑ 8. Hazardous Material Form. ------------------------------------------------------------------------------------------ ❑9. Manufactured Home data and installation instructions including Tie Down Specifications .------------------ ❑ 10. Fees of $------------------------------------------------------------------------------------- ❑ 11. Impact fees as shown on the attached schedule. ------- ❑ 12. California Department:of Forestry plan approval/fees.-------------- -`ir• 1 13. Flood elevation certificate.--------��Department. --------------- 14. Sanitation and plot plan approval ❑ 15. City of Chico plumbing permit. ----------------------------- ---- ------ ❑ 16. Plot plan and business license approval from the City of Biggs. ---------------------------------------------- ❑ 17. Planning approval for (A) Use: (B) Parking: -------------------------- ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- 1119. ---------------------- ❑19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- 0 20. Pre -inspection for required Request to Building Inspector on (Date) 021. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ 0 22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- 023. Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- ❑24. Letter of signature authorization. -------------------------------------------------------------------------------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- C] 26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑ 28. Existing violations and/or expired permits. ---------------------------------------------------------------------- ❑29. ❑433 A, El Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ .--------------- 030. -------------- ❑30. Other �n you issue e ❑ Mail to owner, �IlY1_a/i,��t�o/ actor. 227rllows �vY7VV '% / ;Telephone and hold for pickup at office. ❑ Deliver with inspector. lic + JO�M 0 y 6a' A ��' ��/ ' 0c)Copy G Date: of Haz-Mat form sent ❑ Health Department, ❑ Fire Dep ent;., 0 Air Pollution Date: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, o mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Buildingion counter, by Date: Plans reviewed by: Date: Plans approved by: 0:� Date: Clr Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. ^,n E.H. U E ONIY Plot Plan Attached Floor Plan A chad Sant to B.D. / TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance CIR�YA(,) D� Owner Loc tion AP# Plan Approved for: Sewage Disposal>22 W item Supply: Public Private Well Clearance for dwelling. Other �� -K3L�— Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist 8/96 Date . Y D r Attention Property Owner: An "owner -builder" building permit has ,been applied for in your name and bearing your signature. r Please complete and .return this information at your earliest opportunity to avoid , unnecessary delay in processing and issuing your building permit. No building permit *,M be issued until this verification is received. - k 1. I personally plan to provide the major labor and materials for construction of the /�Y proposed ro ro a m rove P P P P .i. P.. - .. inert .YES NO Z. I HAVEj HAVE NOT[ ] signed an" application for a building permit for the proposed work...,:.;. 3. I have contracted with the following person (firm) `to provide the 'proposed construction: ,. NAME: ADDRESS: .. CITY: PHONE: CONTRACTOR'S LICENSE NO.: 4.' I plan to provide portions 'of this work, but; I have hired_ the following person to coordinate, supervise, and provide the major work: NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. I will provide some of the work but I have contracted (hired) the following-pemi ns to provide the work indicated: - NAME ADDRESS PHONE TYPE OF WORK SIGNED: /< PROPERTY OWNER: SOCL.kL SECURITY NUMBER: DATE: NOTE: May 1995 This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit., 2.26 O.B.-1 NMI Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as.the builder of . . property improvements specified For your protection,' you should be aware that as "owner -builder" you are the responsible party of record on such a permit Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. , If you plan to do your own work, with. the exc epuon ofvarious trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: 0 If you employ or otherwise engage any persons other than your immediate family, and the arork (including materials and other costs) is $300 or more for the entire project, and such persons are not licensed as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State and Federal Governments as an employer and yolk are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers compensation insurance, disability insurance costs, and unemployment compensation contributions. .. 0 There may be financial risks'for you if you do not carry out these obligations,xand these risks are:especially serious with respect to worker's compensation insurance. 0 For more specific information about your obligations under Federal Law, contract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are.allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an `bwnerbuilder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Street, Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned . .. Sincerely, Michael C. Vieira, C.B.O. Manager, Building Inspection J: NOTE: This &xner-Builder Information is required by Section 19830 of the California Health and Safety Code. May 1995 2.27 , BUILDING' DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: ((5530) 538-7541 SORIA, ERASMO Re: Budding Permitc# 00-2411 2460 MAPLE AVENUE Expiration Date: 1/19/02 OROVILLE, CA 95966 t A.P.# 027-070-021 With reference to the above subject, our records indicate that your building permit expires on the above date and your permit falls into one of the category marked below: [ Permit work started, but not completed. Permit maybe renewed for 1/2 the original building permit fee (plus a $20.00 filing fee). The renewal permit will extend the building permit for an additional year from the original expiration date. Should you not renew your permit within 30 days of the expiration date, all work must cease until a new building permit has been issued. For your convenience, we are enclosing a renewal application form and owner -builder form to be completed and signed by you where indicated and returned to this office together with the fee shown. Please return all copies of the application form. [ ] No inspections have been made on permit work. Inspections are required to verify code compliance. We are unable to renew a permit where the work has not been started and inspected prior to permit expiration.. After expiration of your permit, no work may be started until a new permit has been issued. [ ] A final inspection has not been made on permit work. Final inspection approval is required before occupancy. Our field inspector has verified that the building is occupied. Occupancy must cease until a final inspection can be made and final approval given. You have 30 days to voluntarily cease occupancy or to present an acceptable plan for abatement or corrective actions to be taken by you. If our records are in error or should you have any questions concerning this matter, please contact the office. Thank you for your prompt attention concerning this matter. Yrs very truly, C. Vieira, C.B.O. Building Inspection MCV:lt Attachments Chico Office - 411 Main Street, Chico / 891-2751 LAND OF NATURAL WEALTH AND BEAUTY BUILDING' DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: ((5530) 538-7541 SORIA, ERASMO Re: Budding Permitc# 00-2411 2460 MAPLE AVENUE Expiration Date: 1/19/02 OROVILLE, CA 95966 t A.P.# 027-070-021 With reference to the above subject, our records indicate that your building permit expires on the above date and your permit falls into one of the category marked below: [ Permit work started, but not completed. Permit maybe renewed for 1/2 the original building permit fee (plus a $20.00 filing fee). The renewal permit will extend the building permit for an additional year from the original expiration date. Should you not renew your permit within 30 days of the expiration date, all work must cease until a new building permit has been issued. For your convenience, we are enclosing a renewal application form and owner -builder form to be completed and signed by you where indicated and returned to this office together with the fee shown. Please return all copies of the application form. [ ] No inspections have been made on permit work. Inspections are required to verify code compliance. We are unable to renew a permit where the work has not been started and inspected prior to permit expiration.. After expiration of your permit, no work may be started until a new permit has been issued. [ ] A final inspection has not been made on permit work. Final inspection approval is required before occupancy. Our field inspector has verified that the building is occupied. Occupancy must cease until a final inspection can be made and final approval given. You have 30 days to voluntarily cease occupancy or to present an acceptable plan for abatement or corrective actions to be taken by you. If our records are in error or should you have any questions concerning this matter, please contact the office. Thank you for your prompt attention concerning this matter. Yrs very truly, C. Vieira, C.B.O. Building Inspection MCV:lt Attachments Chico Office - 411 Main Street, Chico / 891-2751 vu E -�1�._ . g •� Y ,e p /� !�.w.w.a.t nrawnas�r!��..ai'a+uwnotlwawvrrnru So r � t i A � N o m o a rn �N. n m 0 Z 70 . Z m VI co m m v C9 Hper. (�rncp tju e ' �EP;T ShW t� ()C)7 0 70 .ti; - ',nil, . _ i�"`�iC � . • — F AP Butte County. Environmental`'' Heah. a a, rnJO m f" res . ` ate o �``OVl/ a mnVYs»rC Signature H m� r7' N NN al`% a m M C .e - re OD So ^ ;s rVj 2~ U 3t (Yi O —a `nvirpri k y Mel s � .�.- .• _ _ ..,�• ._--a^� -fir : r • . . rq S/A2 h ------------- SIA • - _. ::�. •:• ate• i T • aPO o m o _ i . APP,,- N 7D By fii V > N Cnvifbnrrne Y sal Health - + N D (/i r _ �aie�- Z m ~ Signature Ol .- --b OD X300 r10 VL - r-, •., Uttezis- w m , Environmental _eaTtli'Pf v H Z Z _\ t .:mss ✓.� . 9iia7V - -a gr� t N`fA 77 y I Y j .- f i 3 9 W Y A � � v C-1P v R s JA : u :i :; 0 16 : i i, OCT =21-159? 15 -30 4n t iPIJ .. �en~aeth:�e' Reed, PaE. _ _ R Civil �nDneet . :9976--SkZxiioas Rc :.zZeddzn� Cz. _95t?OX ,. . Voice/F� 91b-ZT�-3L96 . Department of Housing and Community Development ... October 14, :997 Division of Codas and Standards Northam Area Office P.O. Box 1 ;07 Sacramento, CA S5812-1407 Addendum to Gus -Guard Tuf-I Foundation. Systems Snow Load Chang The Gus -Guard Tuf-t Foundation:Syste{ns:yYere originGlly clesign�d Tor a s�� <r load of ;;0 p This addendum is to raise the atl4vrabte snow load to 100 psf provided that ;hs Gus-C>;arc N:ars are either a replacement on a ogle=to-ona basis..for existing pia -:s o- ^.rein adc ;on, to the existing_ Piers. This is vNy for coaches that have the cornet pier'ins:ai•!adcr. =c; ,t -i_ snow .gad • where the caach is place. Respectfully, : 7;b�lApua'maSG�•cc Appecval. of these plarn does not: otithor" ar. H. Q r' approve ay omission o: or deyiaion�:rom-stvto I --W5 cr :•egulations, cr o cbi_ loco o. -o once_- /No.41063 =� .'-approved Date Kenneth D. Reed, PE }a C lY iL i epotimetf o= F pu! ing and Corc:uni:y rFO� .. •cJ:�j DiwFion ct Codr_ a:a Stc�4•:.iC:.: . Registers Civil Engineer b T q/"s, ^,Lk -11' Nckj. rrp. S" L) T r '6'� S E DET A i L co I @ 0. A r 0 0 ;X Fc- 0 C Ap PL F1 TOP V15y MGP PAD --i L-2 1/Z* TUF- I III I 7L Ile I.Art 10 01 PL-J11E DETtAIL11 S! v1piv Mop PAD —,M G P 2/5' X 80L -S ANo =L;.17--. a Ek m) L 1/4. PLY',kf"000 CC:< -p '"o S 1/-4 r_ --AC-_ ! " G� ALT LM '-NM1t 1/:^ 'LOC -UNC NUT OR C.I. PN T DESIGN LISTEDAiND TESTED BY BSK & ASSOCIATES WAYS T. POLBADO, PE - LISTING NO. F94249 r4 rb, • TEDETAIL E OETAIL) 7 MOIL= oc:IL—E H. 0 M E (.OACH, cfc) —UPPORT GIRL)r:' T YP t CJ X L'i )GHT HEAVYWEIGHT PAO 12 FOP, ROPE- PUL! x t1 ;rill. , -f7 PA 6 SUM Cow" WILDING DEPARTMENT APPROViD Q�OF E S S161�y P() P041 0. Exp,. o A P P R 0 Y E D y —4.-0 ----- 16 KE_ WETH D. REED, F.E. REGISTERED CIVIL ENGENFEER 3976 SL\XvfONNS ROAD REDDING, CA- 960,01 VOIC'E/F,kX 916-24.3-3296 TUF-1 PER-,,),LANENT FOUNDATION SYSTEM GUS GUARD COMT'AiNY P.O.BOX 1228 CATHEYS VALLEY, CA. 9-53005 209-966-3340, FAX 209-966-5549 GENERAL NOTES GUS GUARD TUT -1 1. DESIGN LOADS: LIVE LOAD - 30LB. FLOOR LIVE LOAD - 40 PSQ WIND LOAD - 80 MPH EXPOSURE "C" SEISMIC ZONE "4" • SNOW LOAD 100 PSF 2. THIS FOUNDATION SYSTEM IS DESIGNED TO BE CONSTRUCTED ON A FAIRLY LEVEL SITE WITH NO EXISTING SOIL PROBLEMS. 3. CHASSIS BEAM SUPPORT SHALL BE LOCATED AND SIZED FOR THE LOADS AS SHOWN IN THE MOBILE HOME INSTALLATION' INSTRUCTION. 4. IN AREAS WHEREDIFFERENTIAL SETTLEMENT (D.S.) CAN OCCUR MANUFACTURED HOME SHALL BE READJUSTED WHEN D.S. EXCEEDS 1/4" OR WHEN IT WILL BE ADVERSELY _ s AFFECT MAN WA&URED HOME UNIT. 5. CARRY ALL FOOTINGS DOWN` TO FIRM, UNDISTURBED SOIL. FOOTINGS ARE DESIGNED ' FOR 1000 PSF TOTAL LOAD SOIL PRESSURE AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. _ 6. STRUCTURAL STEEL FABRICATE ACCORDING TO ASIC SPECIFICATIONS, WELD ACCORDING TO AWS SPECIFICATIONS. ELECTRODES - 370 PLATES -ASTM A36 BOLTS•.-, SAE GR 5 =ASTM A449 = ASTM A3725. -7. THE GUS GUARD ASSEMBLIES SHOWN BELOW SHALL BE LISTED AND LABELED BY BSK AND ASSOCIATES FOR THE FOLLOWING LOADS: ALLOWABLE LOADS HORIZONTAL VERTICAL GUS GUARD TUF-1 2200 60004 GUS GUARD MGP 220 6000.9 GUS GUARD PVC PAD (2) 2200# 6000#1 8. DURING PRELIMINARY INSPECTION, THE ESTIMAIATOR SHALL ENSURE THAT MOBILE HOME CHASSIS BEAMS ARE OF STANDARD SECTION. (SEE NOTES) 9. EXISTING COACHES MAY BE RETROFITTED TO RESIST SEISMIC FORCES BY INSTALLING GUS GUARD TUF-1 UNITS AS SHOWN ON THIS PAGE OF TYPICAL FOUNDATION PLANS. 10. THE GUS GUARD TUF-1 SYSTEMS ARE SAFE FOR INSTALLATION IN FLOOD PLAIN AREAS WHERE DEPTH OF FLOODING DOES NOT EXCEED THE HEIGHT.OF THREE FEET. 11. MULTIPLE UNIT INSTALLATION IS ACCEPTABLE PROVIDED THE NUMBER OF TUF-1 UNITS UNDER EACH UNIT IS THE SAME AS SHOWN REQUIRED PER EACH UNIT. 12. SINGLE -WIDE UNITS REQUIRE ADDITIONAL RESTRAINT. (SEE SHEET*3) 13. ALL METAL COMPONENTS AND ATTACHMENTS ITEMS SHALL BE PROTECTIVE COATED. 14. FOR MGP PADS USE 1 1/8 EXTERIOR PLYWOOD WITH WOLMANIZED TREATMENT TO 0.40 MAX PCF RETENTION WITH DRYING AFTER TREATMENT. 15. LIGHT HEAVY -WEIGHT PLASTIC AND STEEL PADS MAY BE USED IN PLACE OF WOLM.AN1ZED PADS. 16. E -Z TIE DOWN USED. ON SINGLE -WIDE. ROUND STAKES (3%4 X 14) MAY BE USED IN PLACE OF THE 1"X 1/8" FLAT BAR WHEN SOIL IS EXTREMELY HARD OR IN ROCK. HOLES MAY BE PRE -DRILLED WREN NECESSARY. - 17. GUS GUARD TUFF• -1 FOUNDATION SYSTEM PROVIDES ALLOWABLE SNOW LOAD TO 100 PSF WHEN INSTALLEli"A H EXISTING STANDARDS REQUIRED BY COACH MANUFACTURER OR REPLACE THEM ON A ONE TO ONE BASIS. �i -.3t11L N6 DI XPARTMEN2 ADDP No. C 053111-0 V:�IRTES 1o' - 70' S_. --Br _ On1 `N�_r �J� 1` .- I E„r. G20I0' L _ S _ S, s RIDGE BEAM SUPPORT AS RC 'D •, BY. X ANUPAC I URER - TYP. Ela F-1 0 o r77 L, 2 N ti' P-- Ri0TA-D SO TLD AVtD.ID CL=^RAMC PR^3_:Ms Serol -2 `Nide Coaches E = 2' MM /1 i' lIux S=6!Min I16'?0ax STA` EARD MH F71" L'ATTEN Piz -RS J AS RE!-0MX=N27D BY THE MANU FLCTL�-Ez) CEP TY=iCAL TFD]UGHCUT. RGL=CAT= AS yEECESSArRY - TY:-,. Double/Muitiple Coaches E 2'Min / 1' `ii2x S = 6' tin x SHEET 2 OF 3 iL r � • LpT. �P 1F� L MGP OR PVC SIERIES 4 SUPPORT PAD' TYP. _ TUF-1 PERMANENT FOUNDATION SYSTEM GUS GUARD COMPANY P -O -BOX 128 CATHEYS VALLEY, CA. 95306 209-966-5540, FAX 269-966-5549 Double'Nde Units Length - ' VYdth up to 44' 45'0 ever Eo 24'I 26' } 29' . 8 } 12 16 . 3 12 . 16 8 12 . 10- Sir,Sie ode Units E6' I Width 10' 1 12' ! 14' 1 16' 4• 4' 4• 4 6, 6. 6• 6 3" 8' 8. 8 T 11 1—i I!—i I I—i [Ori - Nctes: 4 _ oQ ,gfESS/.j���l Gls-G"r pigs a _ be std zt x m'rtr equ -rtn t a;wg each hrm rzi ��. � . P0/ ` ,t• } Haidams ray be avgers• ;res cr cter dices p-MYeed they h. -,e a .1 Z LU �cf b f' N . C G' Exp. 1-70}6 y 7% SD;GLE-WIDE ki CHORAGE 9.091LCOACH Ott i I it: Cuum11 S1 PPCKTG RDE 41JILDING ©EPAA'i'MER" _ GWxt rar APPROVE I iF e _Q C.i:P°f3.3rLc . �fZ - - - - • .. rt _ SNHO ani- T�1F- 1 PETUNIANENT r - _ FOUYDATION SYSTE I rfy I GUS GUARD CONIPA., .P.O.BOX 123 -_ CA'THEYS VALLEY, CA. 95306 2 STAND �; t �', 1-09-966-5540, FA.X•209-966-5549 - IIvST?.LLaTIOi J DEI 'IL --_ SHEET 3 OF 3 MAPLE AVENUE, 44EVIEWED BY WttE CO, FIRE DEPT. t. Atwt, 'DEPT. Of FORESTRY cl womad his omitted twovw' wm% conditions Por. Signature bate ■ L ERASMO SORIA 2460 MAPLE AVENUE' PALERMO, CALIFORNIA 959-68' AP# 027-M-021 ALL STRUCTURES AND EQUIPMENT INCLUDING EXISTING SITE OVERHANGS SHALL BE CLEAR OF ALL EASEMENTS.. A SET BACK OF 3o FT. FROM THE SIDSAND ?p ""FT. FROM THE REAR PROPERTY LINES AND PROPOSED INSTALLATION OF A NEW S-6 FT. FROM THE ROAD CENTERLINE SHALL BE 26' x 66' MANUFACTURED HOME CLEAR OF STRUCTURES AND EQUIPMENT EXCEPT FOR A 2 FT. IEAVE 0VURNAN&L-INC EXIS1 3HOME AND ADDITION, (20' x 40'), WILL BE HOLLOWED OUT FOR STORAGE - ALL KITCHEN AND BATHROOM APPLIANCES AND FIX- TURES, WILL BE REMOVED PRIOR To FINAL INSPECTION. SUILDNG DEPARTMFW EXISTING 24''Px 28GA AkD[)PVF-n PAGE WILL O REMAIN INTACT. MI -7 MAPLE. AVENUE Ok N 2 ERASMO SORIA 2460 MAPLE AVENUE d PALERMO, CALIFORNIA '95968 AP# 027 6-021 t EXISTING SITE PROPOSED INSTALLATION OF A NEW _ 26'. x 66' MANUFACTURED HOME EXISTING HOME AND ADDITION, (20' x 40'), WILL BE HOLLOWED OUT FOR STORAGE - ALL KITCHEN AND BATHROOM APPLIANCES AND FIX- TURES WILL BE REMOVED PRIOR TO FINAL INSPECTION. EXISTING 24'x 28' GARAGE WILL REMAIN INTACT. y T MAPLE. AVENUE Ok N 2 ERASMO SORIA 2460 MAPLE AVENUE d PALERMO, CALIFORNIA '95968 AP# 027 6-021 t EXISTING SITE PROPOSED INSTALLATION OF A NEW _ 26'. x 66' MANUFACTURED HOME EXISTING HOME AND ADDITION, (20' x 40'), WILL BE HOLLOWED OUT FOR STORAGE - ALL KITCHEN AND BATHROOM APPLIANCES AND FIX- TURES WILL BE REMOVED PRIOR TO FINAL INSPECTION. EXISTING 24'x 28' GARAGE WILL REMAIN INTACT.