Loading...
HomeMy WebLinkAbout029-240-01629-24-16 W. F. STONE 50Q8 Midway, Richvale Permit#46-87A(Agficultural Bldg Exemp) 29-24-16 -.774-91E -STONE, Bill 5030 Midway, Richvale'' (elec sery relocation/sf) ;-029�-S4.Q-016. PERMIT#o6-02-98, -STONE, Bi .4 5008 Midwa-y,,Ric Con"t: -Sierra Cascadt%'�C__" e, nc. .Grain:Stg/Com. ILI a s MASONRY WALLS N E S W Ist Lift ,2nd Lift 3rd Lift 4th Lift I -A 5th Lift 16th Lift FIRE WALLS (Occupancy, Area, Prop rty) Gypsum Board 1st Layer 2nd Layer Walls Ceilings f�UA c v fj)—&� 4— 'r� 0 ve-- I f k a COMMERCIAL 029 . -240-016 PERMIT#00-0298 STONE, Bill 5008 Midway, Richvale Cont: Sierra Cascade Inc. Grain Stg/Com &I DATE: 5/4/00 APPLIED TESTING CONSULTANTS MATERIALS ENGINEERING TESTING AND INSPECTION Inspection Report for Concrete/ Reinforcing Placement Client: Sierra Cascade, Inc. 680 Sutter St. Yuba City, CA 95991 INSPECTOR: L. Chapman DESCRIPTION OF WORK: PROJECT: Bill Stone Grain Storage Weather: Clear Temp: 66 Arrived at the job - site at 0715 hrs. to perform special concrete inspection for placement of concrete at Panels 2, 4, 5, 7, 9, & 10. Performed special inspection of reinforcing steel placement for the above locations. Verified proper reinforcing placement, size, laps, spacing and clearances per General Notes. The first truck arrived at 0730 hrs. Verified the mix design as F515. All loads were monitored for the correct mix and slump. All concrete was properly consolidated by use of a mechanical vibrator. Cast I set of 4 cylinders representative of Panel 9, to be returned to the lab for compression testing. Performed I slump test out of load 2. The slump measured 5.5 inches and the concrete temperature was 74 degrees. All work was in compliance with approved plans and specifications. No problems were noted during placement. A total of 27 cubic yards were placed. Departed jobsite at I 100 hrs. Inspector NZ C. C.: 611 10% 3060 Thorntree Drive, Ste. 10 - Chico, CA 95973 - Telephone: (530) 891-6625 - Facsimile: (530) 891-4243 V=OK 0 Not OK Not Applicable Not Ready COMMERCIAL Date LINUE046OR (Plans) OK except #'s Date FRAMING (Continued) ng -Setbac ks- Ease ments- Flood -Slope-So i I Report Ftg., Main; Soils-Llfer Ground.-Ftg. Depth 3. Hold Down s -Bolts- St raps- Embed ment-Hai r Pins 46. Hangers -Post Caps -Anchors -Connectors 47. Roof Shthing-Nailing-Diap.Chord Splice 48. Firewall-Doors-Area-Occp.-Prop. 4. Concrete -PSI -Cert -SP. insp.-Loc. 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Sternwalls, Main; Steel -Bloc kouts-Wra pped 5 . Glu:Prn cert. -Placement -Support eel Buildings-Purlin-Girders 52. Property Line Firewall & Openings 53. Ext. Doors -Handicap Access 6. Reinf. Steel -Grade -Placement 7. Slab; Steel -Wrapped -Wire Mesh 8. Piers -Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 10. Gas Pipe; Size -Anchors 55. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 11. Water Pipe; Test -Anchor -Regulator -Service Test 56. Siding -Nailing Veneer 12. Electric; Underground, Underslab 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 13. Pienums & Ducts; Clearance -Material -Support -ins. 58. Glazing Area -Glass Protection -Skyl i g hts- Plastic- Fire Port. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 59. Shear Walls -Plywood-Nailing-Conn to Roof 15. Mason ry-Rebar-Lifts 60. Insulation -Walls -Ceilings 61. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 62. Corridors -Openings -Fire Protection -Framing Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 16. Water Htr.; Vent -Access -Combustion Air -Baffle Date Card B-1 Date Card B-1 17. Water Pipe; Test & Anchor -Nail Protection Date Card B-1 Date Card B-1 18. D.W.V.; Test -Fittings & Anchor -Nail Protection Date FINAL,4PIans) OK except #'s 19. Sinks -Floor -Grease Trap 45�. Ext. Steps -Door & Sidelight Protection -Landings 20. Hand icap-W/C-Backi ng 64. Exits -Size -Number -Placement 21. Gas Pipe; Size & Anchors - Firewall Penetrations 65. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection Date Card B-1 Date Card B-1 66. Sprinklers -Placement -Test 67. Su�wbed Ceiling-Seismic-Wires-Elec-Light & Mech. Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s A6'-Elec. Trim & Subpanel; Breaker Sizes & Labels 22. Fixture & Transformer Clearance -Ins. Protection 69. Stairs & Rails 70. Handicap -Door Levers -Fin. Floor 23. SinqP Phase -Three Phase -Equip. Bond 1/1/ff- Boxes & No. of Conductors -Stapled 2.�"Romex installed Close to Edge of Studs & C.J. _.26. Equip. Ground made up w/Mech. Fastners-Bond Gas & Water 27. VViring-90'-Protected-Color Coded 28. Subfeed Wire Size ga. Cu or AI-A.C. Wire Size ga. Cu or Al 71. Elec. Outlets at Wood Panel; Int. & Ext. 72. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. Above Floor-Mech. Protection 73. Plb., Elec. & Mach. Equip. Listed for Location 74. Insulation -Foam -Looked in Attic 0 Yes 75. Guard Rails & Deck Construction -Post Caps 29. Fire Resistive-Fixture-Conduit-G.F.I.-Susp. Ceiling 76. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor 0 Yes 30. Service -Riser Conductors & Ground -Main Disconnect 77. Stucco; Brown -Finish 31. Equip. Clearances Panels-Motors-Mech. Equip. 78. A.C. Unit; Disconnect, Electrical, Plumbing 32. Fire Wall Penetrations 79. Vents Above Roof; Plbg.-Appliance-Fireplace.-Clearance to Openings 80. Water Well; Disconnect, Electrical, Plumbing Date Card B-1 Date Card B-1 81. Exterior Elec. Trim; G.F.I. Receptacle -Underground Date Card B-1 - Date Card B-1 .82. Off Site -Parking -Handicap Date MECHANICAL (Permit) OK exceptl#'s 83. Glass Protection 33. A.C. Ducts Insulation & Support 84. Corrections from Previous Inspections 34. Vent Fan; Exhaust above insulation 85. Gas Test -Meters Tagged; Gas -Electric 35. Condensate Drain & Overflow; Size & Grade '186. Water & Sewer Connected -C/0 to Grade -HD Approval 36. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet bate 7. E rgy Compliance Certificate -Other Certificates AB' -Roofing Certificate -Fire Rating Card B-1 Date Card B-1 37. Attic Access & Platform if Furnance in Attic 38. k.V.A.C.-Ventilation-Roof Access 39. Smoke & Fire Dampers Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except #'s 40. Sils, Proper Material & Anchors -Hold Downs 41. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops; Furred Ceilings -Stairs -Chases 45. Headers & Beam -Size & Bearing -Support Fix. Certificate of Occupancy (NOTE: An entry must be made each time you visit the job site) DATE: 5/11/00 APPLIED TESTING CONSULTANTS MATERIALS ENGINEERING TESTING AND INSPECTION Inspection Report for Concrete/ Reinforcing Placement Client: Sierra Cascade, Inc. 680 Sutter St. Yuba City, CA 95991 INSPECTOR: P. Dickinson DESCRIPTION OF WORK: , PROJECT: Bill Stone Grain Storage Weather: Clear/Cool Temp: 58 Arrived at the jobsite at 0700 hrs. to perform special concrete inspection for placement of concrete at Tilt Panel Walls 1, 3, 6, 8, & 11. Performed special inspection of reinforcing steel'placement for the above locations. Verified proper reinforcing placement, size, laps, spacing and clearances per Sheet 5 of 5 of Approved Sierra Cascade Drawings. The first truck arrived at 0800 hrs. Verified the mix design as F515. All loads were monitored for the correct mix and slump. All concrete was properly consolidated by use of a mechanical vibrator. Cast 1 set of 4 cylinders representative of Panel 1, to be returned to the lab for compression testing. Performed I slump test out of load 1. The slump measured 6.25 inches and the concrete temperature was 68 degrees. All work was in compliance with approved plans and specifications. No problems were noted during placement. A total of 25 cubic yards were placed. Departed, job site at I 100 hrs. Inspector C. C. 3060 Thorntree Drive, Ste. 10 - Chico, CA 95973 - Telephone: (530) 891-6625 - Facsimile: (530) 891-4243 APPLIED TESTING CONSULTANTS Treir LABORATORY SPECIMEN COMPRESSIVE STRENGTH REPORT PROJECT: Bill Stone Grain Storage Report Date: 6/1/00 Supplier: Date Cast: 5/4/00 N/A Date Received: 5/5/00 Air Entrainment: Cast by: L. Chapman CLIENT: Sierra Cascade, Inc. Location in Structure: Panel # 9 680 Sutter St. 5.5" Air Temp: Yuba City, CA 95991 .bs.) Sample Size: 6" x 12" Max Size Aggregate: 1" Supplier: Feather River Concrete Admixtures: N/A Mix Design: F515 Air Entrainment: N/A Cement Factor: 5.0 Sk. Concrete Temp: 76 Slump: 5.5" Air Temp: 66 F—DY-1 Structure & Location est F Wg-e� ta ornp. Specified Specimen Date Days Eoad Strength Strength .bs.) (PSI) (PC) Panel # 9 5 1100 7 Panel # 9 6 1 0 3,000 Panel # 9 6/1/00 3,000 Panel # 9 ]====I i nese i ests were periormea in accoruance witn A� i ivit u -.5!i Remarks: Type of Fracture: C.C.: "Z?". __;Z� Reviewed by 0" 3060 Thorntree Drive, Ste. 10 - Chico, CA 95973 - Telephone: (530) 891-6625 - Facsimile: (530) 891-4243 LABORATORY SPECIMEN COMPRESSIVE. STRENGTH REPORT PROJECT: Bill Stone Grain Storage Report Date: 6/9/00 Max. Are Date Cast: 5/12/00 Specimen Date Received: 5/13/00 Load Cast by: P. Dickinson CLIENT: Sierra Cascade, Inc. Location in Structure: Tilt Panel # I (Lbs.) 680 Sutter St. (PSI) (rc) Yuba City, CA 95991 Sample Size: 6" x 12" Max Size Aggregate: 3/4" Supplier: Feather.River Concrete Admixtures: N/A Mix Design: F515 Air Entrainment: N/A Cement Factor: 5.0 Sk. Concrete Temp: 68 Slump: 6.25" Air Temp: 58 7 -EFF -1 S tru ct-5-r-e-E E o c at i on es Max. Are orrip. peci ie Specimen Date Load EStrength 7Stren.-th (Lbs.) (PSI) (rc) Tilt Panel 9 1 Tilt Panel # 1 Tilt Panel # 1 69 0 3,000 Tilt Panel # 1 3,000 i nese i esis were perrornieu in accoruance wnn A�� I M Remarks: Type of Fracture: C.C.: Reviewed by 3060 Thorntree Drive, Ste. 10 - Chico, CA 95973 - Telephone: (530) 891-6625 - Facsimile: (530) 891-4243 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street - Chico, CA - (530) 89172751 7 County Center Drive - Oroville, CA * (530) 538-7541 CORRECTION NOTICE PERMIT NO. A routine inspgdtion indicates that the following violations of butte county Ordinances exist at the above addrgKs and should be corrected. Please notice this office when correction of work is completeX If you have any questions pertaining to this matter, or need additional explanation, plep7§16y6n tact this office immediately. Date f 60 inspector 69 L---1 REV 10/92 . '41 T"; COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Orovil1le, California 95965 * Telephone (530) 538-7541 PERMIT NO. Rev. 12/96) APPLICATION AND PERMIT 00-0,2?'s il - ASSESSOR F4RCEL NUMBER 029-240-016 ZONING A 4b BUILDINGPERMIT OWNER RTT i ,;TnNE TELEPHONE 882-4485 SO. Fr. OCC. BUILDING VALUATION . OWNERS MAILING ADDRESS —5100 PO BOX 189 RICHVALE, 95974 112,200 -nn CONTRACTOR'S NAME SIERRA CASCOE INC. TELEPHONE 1673-4155 CONTRACTORS "UNG ADDRESS 680 S = ER ST., YUBA CTTV _f�'* 95991 CONSTRUCTION LENDER LENDERS MAJUNG ADDRESS Fireplace Total Valuation $ 119-9n)-oo ARCrE OR W6t�� U ENSE NO. 12c 5019 Filing Fee $ 20.00 —Permit Fee $ 685.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 445.25 BUILDINGADDAESS 5008 MIDWAY, ETCHVAIE Energy Plan Checking Fee $ $ PERMIT FEE $ 1.150.25 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 1 20.00 USEOFSTRUCTURE GRAIN STORAGE SF 0 Duplex 0 Mobilehome 0 Other SPECIFY Each Trap 7.001 Solar or heat pump water heater— 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New 0 Addition 0 Remodel 0 Utilities 0 Installation 0 Other 0 Describe Work: ONE STORAGE BLDG. 60985 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home IS I G I W PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20-00 600V R LESS Main Service 20.A OR LESS 23.00 no LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: 0 1, as owner of the property, or my employees with wages as their sole compensation, do the work, and the structure is not intended or offered for sale. 2"llwas owner of the property, am exclusively contracting with licensed contractors to construct the project. 0 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: 0 1 have and will maintain a certificate of consent to self -insure for workers, compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, forthe performance of workforwhich this permit is issued. MY workers' compensa on insurance garrier and ic um er are: Carrier C -l'. _ '0 1 1W It 7pe W � Di -5 L�X4 F 4 1 �. Policy Number 1-11786 - (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 0 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. "57— M X &;�z'skte- Date a_1 SignalFure of Applicant - 0 Owner 0 Contractor 0 Agent An OSHA permit is required for excavations over 60'.'deep and demolition or construction of structures over 3 stories in height. _,2_2 Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP OR ADDNS. & ACC. BUDS. _SO. 3.5yFT. COT. -0 MU LTH' @7.50 1 q nn R P.O"WEL AF= US 4. E 0 CIR. Ex. Occup. OUTLET OR FIXTURES SAL@ .50 FIXED APPI.M. OR Ex. Occup. OUTLETS (RESID.) EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring PERMIT FEE $ 58.00 MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEP_ $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE$ 1 208 _..,2 OFTA ;0rMA _f�ll CDF This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By DaJe PERMIT EXPIRES ON J(D, tq) J ReceiptNo. 2959997 T455. M &-_-E C- f /7 S I WHITE-D.D.S.-B.D. CANARY-ASSESSOF( PINK-INSPECTgR GOLDEINFIOD-TPPLICANT J% COUNTYOF BUTTE - DEPARTME14 O)7DEVELOPMENt SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 PE"IT "PLICA TION DA TA SHEET OWNER: 13, ASSESSOR PARCEL NUMBER: 02c?—;ZZ/0,/p/b/ Proposed B�ildingb`se:,r,,,, _Building Inspector: Date: At time of permit application, I was advidd the foHowing data must h—esubmitted prior to per&ft processing and/or issuance: Date Rece#ed By 0 1. All items have been submitted -------------------------------------------------------------------------------------- 142'.IP'lot plans, 3&ets, signed by the preparer of plans - ------------------------------------------------------------ 03. Complete plans, 3,10ets, signed by the preparer of plans - ----------------------------------------------------- Wlgrg�eered plans, 38>ets, with wet signature on plans. All engineering must be shown on plans - -------- El 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ E16. Energy Design Compliance and supporting documentation - ---------------------------------------------------- 00MStafement of Intent ' for Non -Heated and A/C Buildings - --------------------------------------------------------- HSazardous Material Form - ------------------------------------------------------------------------------------------ El 9. Manufactured Home data and installation instructions including Tie Down Specifications ------------------- @96ees of$ ------------------------------------------------------ &4,mc El 11. Impact fees as shown on the attached schedule - ----------------------------------------------------------------- El 12. California Department of Forestry plan approval/fees - --------------------------------------------------------- *15it0 elevation certificate - ----- U4:0-'16 ------- 51 - ---------------------------- ttj d plot plan approval Ok-o �Health Department. ­­­­ -------------------------------- ation anc 1tv of C Ico y of Chico plumbing permit ------------------------------------------ �; ------------------------------------------- El 16. Plot plan and business license approval orn th�tC! C f Bi�%s - ------------------------------------------------ Planning approval for (A) Use.- Uv--, st T-) (B) arking:. QYContact Land Development about 0 Improvements, 11 Drainage, 0 Legal Parcel. El 19. Encroachment Permit for driveway (construction approval prior to occupancy) - ---------------------------- E120. Pre -inspection for required. Request to Building'Inspector oii -'tDate) 021 Contractor's license information. (Number, Name Style, Classification) - --------- e, / ------- 22 --------- I -------------- Workers' Compensation carrier and policy number - ------------------------------------ Owner-Builder Verification (Given toowner El, Mailed to owner 0) - -------------------------------------- 024. Letter of si ature authorization - -------------------------------------------------------------------------------- gn E125. Recorded C�opy of Agricultural Acknowledgment Statement - -------------------------------------------------- E126. Letter of inten*t on budding use - ------------------------------------------------------------------------------------ 1127. Manufactured Home utility clearance - --------------------------------------------------------------------------- E128. Existing violations and/or expired permits - ---------------------------------------------------------------------- 029. 043-3-A,—DGiant Deed, 0 M.H. Title, 0 Check to H.C.D $ - --------------- 030. other. ------- When you issue the permit, process as follows 11 Mail to owner, OMail to contractor. 6felep'lione 35 4 cY 8,5 and hold for pickup at office. 0 Deliver with inspector. Applicant: Date: 0�?-/5-C*Td Copy of Haz-Mat form sent 0 Health Department, 0 Fire Department, &Air Pollution Date: BY: Copy of plans sent 0 Health Department, 11 Fire Department, 0 Othe Date: BY: -d: 11 Plan Check List 1. Index permit application for the above items numbere i A 7P 2. Addibonal i 7 A .e�� rgner as of the above required datalby of phone, tmail, 0 Building D&ision counter, by Date: 3 Q&a:c�, designer, owner, was advised of the above required data by 0 phone, 0 mail, ��uilding Division counter, by Date: Sa Contractor, designerlt!Mzpas advised of the above required data by 0 phone, Xmail, 0 Building Division counter, by Date: 3-q-0 Contractor, designer, owner, was advised of the above required data by o phone, 0 mail, o Building Division counter, by Date: Plans reviewed by: Date: Plans approv�d by: Date: Sets of plans on hold in)QPlan Cabinet, 0 A.P. folder. Note trandef by: Date: Yellow Copy - Department of Development Services, Building Division. M 171 7� FMIT- --.;r P 'VK 71F R� E.H. USE ON&Y - 1 Not Man Artadzi. Hoar Plan Attached Sent to 8.0. INV— j . TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance owner (Xocaiio"n AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for dwelling. Other g;LaZ NiOULONLITGWINT "T IVA "NIZA, -�E.H. LIS"LY Plot Plan Artactied I Floor Man Anaqheck_ SLVI— Sent to 8.0. TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Aaz -.�7W--OAVI �m 1 .0 oe!�7 2-1 A - �562 /"14//; CX 7 Owner a-oc,aiio'n AP# Plan Approved for: Sewage Disposal --Water Supply: Public Private Well Clearance for dwelling. Other 4La -A&n4,a?=-2 - Hold final for: Final clenr nce O.K. for: NOTE: L P\ Environmental N th Specialist Z/O 6 Date COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVJILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE OWNER o rJ A.P. # PROPOSED BUILDING USE S-�-oQAGf_ t5U( L c& WG DATE- 3-2-00 1. BUILDING PERMIT FEES Balance Due ................ $ Additional Fees Due ........... $ Additional Fees Due ........... . $ Revised Pian Checking Fee ........ $ 2. SCHOOL DISTRICT FEES 91 G6_5 (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ........ x $360.00 = $ Units Commercial (sq.ft.)... 57(00 x $0.03 ["53-00 Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) X_ =$ #Units Amt. Commercial (sq. ft.). _ x - _$_ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER RECEIPT # DATE REC At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE Pursuant to Government Code Section 66020, you are hereby notified that items 2,3,4,5,6,8,9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Budding Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 2/97) I BUTTE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT HAZARDOUS MATERIALS AND EMMISSIONS QUESTIO NNAIRE (A Building Permit cannot be approved -without this completed form.) BUILDING PERMIT NUMBER& 6 -0,-2 9 �1, A P N Firm Name /6 (11 '5faL Address 5o3o A�Awajl Igg Nature of Business r6_t(Vxw& Contact Person Phone # 1. Dqps your business or that of your tennants handle, store, or transport hazardous materials? EI NO OYES NOTE: Hazardous materials are defined as any material that, because of its quantity, concentration, or physical or chemical characteristics, poses a significant present or potential hazard to human health and safety or to the evironment if released into the the workplace or t.he environment. "Hazardous Materials" include, but are not limited to, hazardous chemicals, hazardous waste, paints, oils, lubricants, fuels, flammables, combustibles, corrosives, gases, and any material which a handler or the administering agency has a reasonable basis for believing to be injurious to the health and safety of persons or harmful to the environment if released. 2. D u orwill your future tenants handlestore, ortransport 55gallo.ns, 500 pounds, or 200 cubic feet (at s, t /Oy'di a ',ird temperature 4 pressure), or formulation containing hazardous material? NO OYES 891-2727 If you answered YES to 1 or 2, contact the Butte County Environmemtal Health Department (916-kWR§J) for a review of the project. Is the business/facility/operation s�c�ol site? N( NO OYES IF YES, name of school. to be located within 1000 feet or the outer boundry of a school or 4. Does the business/facility - /operation have the potential to emit any air pollutants; e.g., dust, soot, odors, fy�pes, vapors, or other volatile compounds? EJ NO 0 YES IF YES, contact the Butte County Air Pollution Control District (916-891-2882) for permit requirements. /`&W 5-h� 9 Owner or Authorized Company Representative — -15-OD (Si§aature) (Date) BCEHD BCAPCD The applicant has met or is meeting the applicable requirements of Section 25505, 25533, and 25534 of the Health and Safety Code and the requirements for a permit from the Butte County Air Pollution Control District. The Above Regulations Do Not Apply To This Facility. BCEHD Signature Date BCAPCD Signature Date WHITE- Building Dept .0 YELLOW- Env. Health 0 PINK-APCD 0 GOLDENROD- Fire Dept. q, FEDERAL EMERGENCY MANAGEMENT AGENCY O.M.B. No. 3067-WT7 NA71ONAL FLO.00.INSURANCE PROGRAM Evires July 31, MM. ELEVATION. CERTIFICATE - Important, Read the Instructions on pages I - 7. 3 � NOW � BUILDING STREET ADDRESS (IricludIng Apt., Ua SWts. e�-- -- — - I I . - arKVOr OW9. No.) OR P.O' . ROUTE AND BOX NO.. f-KVP-tK I T Ut:5CKIFnPN (Lot and Block Numbers, A e A)n - DZ, 9 - 14-0 - 01 (� BUIL;�NG USE (e.g., Resklentlal, Nonm�--entlal. Addition, etr- Use Comments If necessary.) ez ir-�m^2 V %—I I lwr%P%L. r1WKW.Vr4tALUATUM!. SOURCE: GPS (Ty") 4NAD 1927 �-J NAD 1983 USGS Quad* Map L-1 Odw. =u I IUN 5 - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. �F�IPN'U-NITY NAME & COMMUNITY NUMI U NAME B3. STA—TE '6 X7 B4. MAP AND PANEL . B5. SUFFIX NUMBER B6. FIRM INDEX, B7. FIRM. - PANELDATE B8. FLOOD 89. WE FLOOD ELEVA�S) Cex-xl C DATE , j,).,tgB V- EFFECTIVEIREVISED TE(S) [ qone AO. use d9oh of ftodng) Rln lnefie�#. #h- rl— UW UMM F-1000 mOvauun torc) qa1a or. one noodjlepth entered In B9. FIS Profile L_1 FIRM Community Determhecl LA (Descdbe): __I Other B1 1. Indicate the elevation datum used for the BFE In B9: JX NGVD 1929 1-1 NAVD 1988 L-1 Other (Describe): B12- Is the building located in a Coastal Barrier Resources System (CBRS) area orOtherwise Protected Am (OpAp L__Iyes J�KjNo Designation Date: SECTION -C - BUILDING ELEVA71ON INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: �-JCionstrucfion Drawings* J413uIlding Under Construction* L_pnighad Construction. *A new Elevation Certificate will be *requlred when construction of to building Is complete. C2. Building Diagram Number (Select the bUldIng diagram most similar to the building for which this certificate is being completed - see pages 6 and 7. If no diagram accurately represents the building, provide a sketch or photograph.) C3. Elevations - Zones Al -A30, AE. AH, A (with BFE), VE, V1430, V (with BFE), AR. AR/A, ARIAE, AR/Al-A30, ARIAH, AR/AO Complete ftems C3&4 below according to the building diagram specified In Itern C2. State the datum used. if the datum is dftwt frorn the datum used for the BFE In Section B, convert to datum to that used for the BFE- Show field measurements and datum conversion calcuilabon. Use the space provided or the Comments area of Section D or Section G, as appropriate, to document the datum *conversliom Datum kZeVD ConverslorVCornmarft Elevation reference mark usedl>��. Does the elevation reference mark used appear on to FIRM? Yes No NJ a) Top of bottom floor (including baseme.nt or enclosure) fL(m) .1 q FE 0 b) Top of next higher ffoor 7- fL(m) 0 c) Bottom of lowest hortzontal structural. member (V zones only) — fL(m) E. 0 d) Aftachad garage (top of slab) fL(m).. U e) Lowest elevation of machinery and/or equipment 0 servicing the building '24 /0Z 0. RCE Lowest adjacent grade (LAG) --/zl -2- Expires imlolll g) Highest adjacent grade (HAG) fL(m) '01w. 0 h) No. of permanent opening& (flood vents) within 1 fL above adjacent gmde OF C 0 1) Total area of all permanent openings (flood vents) In C3h sq. In. (sq. cm) =U I IUN 0 - 3UKVEYOK ENGINEER. OR ARCHITECT CERTIRr-ATION I 1 *0 LAN ulludug" 13 w De 319nea apa sealea by a land Surveyor, engineer; or arctdW authortzad by law to certify elevabon hfornration. I ceiffy ftt the infiormadon In -Secdons A B, And C on ft cerdficate represerlts my bed efforts to interpret dw date'avadable. understand1hat SnY WW statement May be punishable by flne Or lmlodswnent under 18 U. S. Code, Secdon lool. f'CZrn01=n-. LIA.— I I I- 1-r— � f -[-� _3 (.-' Ir- -24 - T11LE C L (:2-+ 1%r%M jtf7eiaz 2-6 YM RE vz _ry 1,eg- '�'910 SINX �>24--W CITY STATE 23P SIGNATU!�� P'q*+DJS6F . (–A - D' /-.q1L1TVE 1 , -71 wffm _ ;:PUA Fnryn A1-11 Al Ir. QQ APF RR/PR1qF.F4,nF: ;;n.P ri'WnWI IAnr)N RF:PI ArJ:.q Al I PRP%ArA Vt RVrWlAm * .0 IMPORTANT. In thOw sPacM copy the BUILD G STREET ADDRESS (Inioludino APL. unit. Suft, and/or 5Idg:1N6.) UR _P.0ROUTE AND BOX NO. roe3 CITY, STATE CODE I, c L1,4 L Ci- SEC71ON D - SURVEYOR. -ENGINEER, OR ARCHITECT CERTIFICATION (CONI Copy both sides of this Elevation Certificate for (1) community officlai, (2) Insurance agenlicaimpanyi and (3). COMMENTS- Lb!� I, < AC, 4-7,a� L� . Jr - J 17 - I--, INUED) bUilding'owner. _A� X-11006.1 V IN .ell Check here'if Ottachm6nts SECTION E - BUILDING ELEVATION INFORMATION (SURVEY N& REQUIRED) FOR ZONE AO and ZONE A (WITHOUT Bfq For Zone AD and Zone A (w� BFE�'compiete Items El 111nou . gh Ell the 60vadOn Ckftiti is Intended for use as suppc!�ng, informadon thr a LOMA or LOMJ�-F, Sectbn C must be Cqnpleted. El. Building Diagram Number /* (Select the building diagram m0itsimilarto the bullclliig'fbr�Aihic� this _r. see pages 6 and 7. If no dia cef.tificate is being completed _grann accuratetY.represents the building; ��de` a sketch or photograph ln.(cm below 1 E2. The top of the bottom door (in-ciud-Ing basement or encios64) of thi building Is ILL0 f,t-w L-21 above or L (check one) the highest adjacent grade. E3. For Zone AO only-, If n6 flood depth number is availablejs thdtbg of the bottom floor elevated In.accorclanoe wfth'ft community I a floodplain managenrient klnan"ce?/�'_J'Yes No '[�:_J'UnknoWn.'. The loiiai officialm,u nf, stoertifythisi ormation in Section !3. SECTION F,;�P�RQJ,3'ERTY OWNER (OR OWNER-3-REPRESENTAT11M CERTIFICATION t The property owner or owner's' authorized representativewho . completes Sections A, B, and E for Zone A (without a FE issued or communitywissued 8FE) or Zone go must sign* here. '_­ � _�` I - . Q UE - I - - . Check here if aftchiments SECTION G - COMMUNITY JNFORMA71ON (OPTIONAL),-, The lcocal official who I's authorized by law or ordinance to adrninister mmunitys floodplain manage 'ant ordinai-n-G-9 can cornpi �te Sections A. B.' C- (or Q, and G.of this Elevation cartincete. m the applicable Item(s) and sign below. G1. 1-1 The . infbnT%ad.on in.Section C was taken (rOrn Other documentation that has b4en'signed and embossed b� ai licensed surveyor, enginew, or architect 'who is authorized by state or local -Jaw to certify elevation information. (indicate the sou'rce and date of the el,e�;d8� datiiin", the Corhments area below.) G2. L-1 riiuni Adil coinpleted Section E for* a buldlng!pcated in . Zone A (without a FEMA -issued or communit . y4ssued BFE) I or one, L W. "I e informatJoni'(1t4ms G4 -G9) is Orovided for ccmmun�y floodplain management purposes. G4. PERMIT NUMBER 'DATEF'�IT ISSUED G6 DATE CERTIFICATE-OF—COMPLIANCE/OCCUPANCY., TC 1 ISSUED G7. This pemid" has been issued for L-1 Now Construction L-1 Substanda I I Im emer�; G8. Bevati N" -` , , - . . �Tv on of as built lowest floor (including basement) of the building Is: - - fL(m) Dattun: G9.. BFE or (in Zone AD) depth of flooding at the building afte.11M LOCAL OFFICIAL'S NAME TITLE COMMUNITY NAME TELEPHONJ!�_ SIGNATURE Dk1% COMMENTS 7- I—LCheek here if attachime F91164APA""All-11 At Jr. 40 PFPI Ar.r-q Al 1 PPF7()l _Jq0:nIT1rAI!q ... -.N AJIWA— I-OUbW Li Nsl r- 00 �o r vo tn* 'lid Av'i"M i FEB. - 0 1' 00 (TUE) 16: 34 MER CONSULTING TEL:916 89S 1000 TRW RSDI Property Data: Butte, CA 1996-91 Yap: 029-24 - — — — — --- — — — L fo L MN IhIA-M 30 N 1 960 z 41 V3 k6 c: 0 P. 01 MN MAR. 09(�YED) --12:08 ' MER CONSULTING TEL:916 893 1000 P. 01 TO: MER,l,,---:-.-:-:,...:-11':l... 7 f- s "f -I C. FAX TRANSMISSION SHEET JOB#/L-.93 cl DATE T/gje�._ AirTwS:�A,9-7- PROJECT �'Tboa-=-,� WE ARE TRANSMITTIMNG THE FOLLOWING: D E S C R I P T 10 N "E-5SAIQE__& 67d) __IAZTrA ?o Z_O" ( ) - - . - I . . M.AK 1 3 OR �7 COUNW 01 1 L -LAND DEVELOP�EN'T DIV �Ljlz..C_ ye- r- -ro/F a/v OF -5 97.5 ell— '40017 tj MAR. - q8' 0 0 (WED) 12': 0 8 MER CONSULTING Az-�-,*- /0 7, 1 /cv, 57 390 30, TEL:916 893 1000 P.02 TED - STAT -Ed--* hr',�."OF THE INTE . RIOR )OICAL SURVEY-,,-,: MAR. - Q 8' 00 (WED) "11: 0 9 MER CONSULTING TEL:916 893 1000 P. 03 Q, N WTI Lh T%ZZ L48 ess ....4 -;We PO V -r. tlA ru L4 00 9 L4 Z- 00 P4 Q, N WTI Lh T%ZZ L48 ess ....4 -;We Attention Property Owner: -owner---builder' building permit has been applied for in your name -and beafing your signature. Please complete. and. return this information at your eartiest olp,ortunity to avoid unnecessary delay in processing and issuing your building permit. No'building pdrr!0t.vV*,,, be issued until this verification is received., I personally Plan to provide the .'major labor and -materials for construction of the rty P. proppsed.propf. im. rovement: YES[ NO[ 2. 1 HAVE[ -l''HAVENO fi 'on a T I signed an'app, cati J f&i bui for the proposed work--.,_;.. ing -person (firm)- to"- p 3. 1 have contracted with the fbllo'v�* r� -thei; -pro'pnr construction: NAME: Ira T1 CITY: - Ytt ho 6 L -(A-: '-q- q ,ADDRESS:-'*/,) 9()'­S�j tter, :5f PHONE-.­[��)-3-�:V_Iff CONTRACTOW S. LICENSE NO.- -"7�+,q, qqqf! n' *'*de* portions 6f this w -&K -but I have hired the following person to 4. 1 pla' to�pfovl coordinat�, supervise, and provide the major work:' NAME: ADDRESS: CITY: PHONE: CONTRACTOR'S LICENSE NO. 5. 1 will provide some of the work but I have -contracted (hired) the followipg-perisons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK; - SIGNED: PROPERTY OWNER: SOCLXL SECURITY NUMBER: DATE: NOTE: This owner -Builder Verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. May 1995 2.26 ....... ...... Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the buUder of property improvements specified. For your protection, you should be aware that as "owner-buildee, you are the responsible party of record on such a permit Building permits are not required to be signed by property . owners unless they are personally performing their own work. If your work is being performed by s omeone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all perm its for which they apply. If you plan to do your own work, with the exce�ti6� of various trades that you plan to subcontract, YOU should be aware of the following informati6iifor Yo&b&efit and protection: 0 If you employ or otherwise engage any . persons other than your immediate family, and the'work (including materials and other costs) is' $366"'or the e'fitir'e project, and such --peisons -are -not licemkd as contractors or subcontractors, then you may be an employer. 0 If you are an employer, you must register with the State.and. Federal Governments as an.employer and. you. are subject to several obligations including state and federal income tax withholding, federal social security taxes, I orfipensation contributions. workers compensation insurance, disability -insurance costs, and unemp oyffient c' 0 There may be Emancial riiks'for-you if you do not carry out these obugations,'Iand these risks.are esp�cially serious with respect to worker's compensation. insurance. 0 For more specific information about your obligati ons under Federal Law, cont ract the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under State Law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "ownerbuildee, building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contracting the Contractors State License Board in your community or at 1020 N Stree4 Sacramento, CA. 95814. Please complete the "Owner Builder Verification" on the reverse side of this form so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. ..- Sincerely, Michael C. Vieira, C.B.O. Manager, Building Inspection NOTE: This O%-vmer-Builder Information is required by Section 19830 of the California Health and Safety Code. Mav 1995 2.27 March 9, 2000 Bill Stone P.O. Box 189 Richvale, CA. 95974 0 Department of Development Services Building Division 7 Countx Center Drive Oroville-CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 029-240-016 3uilding Permit Number: 00-0298' This office reviewed the above referenced revised building plans. Please respond in writing to each comment by creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re -check and approval of this project. Provide additional information and/or make revisions to plans, specifications and calculations as follows: I . Hazardous Material form is enclosed and must be completed and returned prior to the issuance of the building permit. 2. The Flood elevation certificate submitted with this application does not appear to be correct and will need to be revised. A Plan review approval by the Butte County Building Division engineer has not been completed at this time. 4. Sanitation and plot plan approval is required from the Butte County Environmental Health Department. 5. Complete and return the Owner -Builder Verification form. 6. Balance of Building Permit fees $752.57. 7. Complete and return the Butte County School Impact fee certification form. 8. Sheriff fees = $153.00. If you wish to discuss any requirements, you may contact me at (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Sincerely, Glenn Gibbons Plans Examiner I of I March 2, 2000 Bill Stone P.O. Box 189 Richvale, CA. 95974 Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 029-240-016 Building Permit Number: 00-0298 This office reviewed the above referenced revised building plans. Please respond in writing to each comment by creating a response letter. Indicate which detail, specification, or calculation shows the requested information. Your complete and clear responses will expedite the re -check and approval of this project. Provide additional information and/or make revisions to plans, specifications and calculations as follows: I . Classification of the building is the critical first step in the effective use of the Uniform Building Code. To an even greater degree, the proper determination of occupancy and type of construction is the basis for all other code determinations. Provide a complete code analysis for the entire building and include the mixed occupancy ratio. This analysis must include the exit access, the exit, and the exit discharge. 2. Expansive soil is indicated on this parcel and the foundation must be designed if this condition exists at the construction location. 3. Obtain Planning Division approval for use and parking requirements. 4. Contact the Butte County Land Development about Improvements, Drainage, and Legal Parcel requirements. 5. Plan review will continue upon receipt of the above items. Additional comments may be generated from your response above where plan documents were incomplete, inconsistent, or not adequate to depict code compliance. 6. Plan review by the Butte County Building Division engineer has not been completed at this time and additional items may be required. 7. Sanitation and plot plan approval is required from the Butte County Environmental Health Department. 8. Complete and return the enclosed Owner -Builder Verification form. 9. Balance of Building Permit fees will be determined when complete building plans have been received. 10. Complete and return the enclosed Butte County School Impact fee certification form. 11. Sheriff fees = $153.00. I of 2 0 0 If you wish to discuss any requirements, you may contact me at (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Sincerely, Glenn Gibbons Plans Examiner 2 of 2 Y" 1.28 ' L. --, , B ...... DATE).6 SUBJECT ....... ..... . ......... cy ............ .. .... SHEET NO. or CHKD. OV ... . .... ............ DATE ........................ ....... 2� .. JOB No. 4 T ...................................... .. . ............................................... . ...... . ....................... ... . .. . .. . .. ... . ...... 7 -h 6 W/ 5,i Z,7' VL,, I � h h C rC A& Al hL -Up S7&LPS 4:�r- r-/ Ce S 7'�) r -a,5 7- /� (2. p C� r) 0 /5 W I e Su)o poo r �-& c� A6p /n Z o t�4 r�n Vt14C&I ZOan - /)� /_0 / 5,00/7 - L6' E7� il o I&n -/ Flal (:7/ rLp g r r t c,!�- / pi S -Ibrgye' -. / / - 7-c? k? IC�-6 rw -Ta � le 2. rm ng Devc. 13n b ty 4-on2oq A)evj60ve,— 4 1�10rrt,, walk�pr Z'I'Cl Oak -IS CAD� /I r, 2- M/ -2 P- W h W= llx12 7�?2 J,� 72 F2x/2 Pb"&/5 Vvj 11 be 'I) 777/6k -3-d-b6 r�.S cr& Ae v /-7-1 5,3 7 2 -5 0 -3 f3.(a- r Z L/ ro de 2 x ea C) -2 -1 X/ 2,7��- 2- 5-d /> ;? 3e; 3 4AZ, P/Q cc., V r co j COVA/wf wf Vo Y-�, 2,7�_" 4v VS& Z6, 0 792-1 Loa ci T T- Z -6 �_s t de . ...... . ........................... SHEETN .............................. SUBJECT 1.:�.Z...ZY 0 . ..... ....... OF 4 C.HKD. aY ..... ................ DATE ........................ ...... ..................... .. . .............. . ................................ ............. ................ JOB NO. ............................ .................. ; .................................. .. . .... . ......................................... . .................. . .. . .. . .. . . . .. . ...... ........ . .. ....................... ....................................... . .. 3/ 2 e. x >e-. 7, A d ;;L4-0 4- bo 7,�'b- w o m�al( -�ak&p, -�-- Fr Lt) ep d v, a 47 -c -)-w ivv i pi cl 2-E/, 7 34. 110 Y -z- c- a -f- 4u-jo o --t2 57 6 �S- >e-6 3 < C'o V) Y7 G 0 0 p d- -P P&Ia �o f� 4,c Ila n A, e" ----------------------- -e ZI 3-- -):—I _rn d� -ci 4�6 co r7k7ec--( 101-1. -C-k70 P7,P7 0 AO IVIQ/0. i-er, we 4� L� Ale, 47///,Cp 0 C L) 0 1-7 MIQ I W. e 0 C - 4' a. r�, //,7 bec-ous& poll&lr- are levp -W 7b 6 -SUBJECT AT, L 7 t CHKO. DATE. ATIZ mo SHEET NO. _J__ OF JOB NO. Rice cotl Le S/Vreol W/7� r1c) W)VICI or 0 e ki /do LV Wo r WOej/c/ 7. S- IspA4 63 vc-rn 4::;-aw ao ciw c 2- 0 7� R/cc coo Zoe �OkIA?� 57CI1Z411r,_ 6 7, ty 11:r- S74 r,7-7' �4.67 -A o A,- , 0 S C�&.s- t ' c jr pi v d� 1�lle lo c-, M e- boa py) a ike Y461-:) e -,F t* -e wo 7 1 !.4 f-' ri ro a co /7 tt4 61 4s -7 D6 3 3 4- IV16 tW e Al TM WC7 6/ n If IV� CO of ji'/& 64r �? Z_ 4- 2 ev /I— SHEETNO . ....... OF JOB ......... DATE/ 9Z 9 SUBJ ECT ....... / ...... CHKD. 13Y ... .................. ........................... r .................. DATE ................ . ...... ; ........................... . ...... ..................................................... . ........................ . .............................. ................... . .. .......................... . .... . ... . . ... IV16 tW e Al TM WC7 6/ n If IV� CO of ji'/& 64r �? Z_ 4- 2 ev /I— SHEETNO . ....... OF JOB NON-RESIDENTIAL BUILDINGS ENERGY CONSERVATION STANDARDS Statement of Intent for Non -Heated and/or Non -Air Conditioned Buildings 1, -**1311 / S*rAL owner of the building to be constructed as a (please print) PIC, f zslyaae h U I I et 1 VV4 under at 56D8 At d -Li _J (bldg.permit no.) (location) RL([" hereby certify that I do not intend to heat or cool this building in such a manner as to be subject to other than the mandatory sections of the State Energy Requirements. I understand that if I do heat or cool this building in the future, that I will be subject to the energy requirements in effect at that time. I understand that if I change the use or occupancy of this building in the future, that I will be subject to the energy requirements in effect at that time for that specific occupancy. I also understand that if I become subject to the energy requirements in the future, it may.be necessary to redesign and/or alter (1) the building envelope, (2) the insulation requirements of the heating, ventilating, and air conditioning systems, (3) the heating, ventilating, and air conditioning equipment, (4) the service water heating, and (5) the lighting of the building to comply with the regulations. I understand that any of the above changes will require me to obtain the necessary permits, inspections, and approvals from the Butte County Building Department. Signature of Building Owner Mailing Address PL & im Telephone No. MEMBER SCREW (ONE) EACH PUI RAKE ANGLE * RAKE TRIM MEMBER SCREW AT 12" O.C. STITCH SCREW AT 12" O.C. O.S. CLOSURE WALL PANEL TAPE SEAL (CONT.) ROOF PANEL PURLIN ) 1/2" X 1" M. BOLTS X 1 1/4" A325 BOL __E ENDWALL' ELEVATION ,R QUANTITY) D RAFTER DWALL COLUMN iAPE VARIES) SECTION THRU RAKE AT COLD -FORM FLUSH ENDIVALL *NOTE: TRIM PROFILE MAY VARY. NO, BY CHKD. DATE NOTE: These drawings ore intended to depict general installation of item(s) DRAVANG NO. BY described above. Some item(s) may have been omitted for clarity 1_0 !_t FM 6/4/99 KG - 6f presentation. Consult your erection manual or additional S—Sheets for. further guidelines and/or clarifications. S11 MEMBER SCREW - (ONE) EACH PURLIN RAKE ANGLE *RAKE TRIM MEMBER SCREW AT 12" O.C. STITCH SCREW AT 12" O.C. O.S. CLOSURE WALL PANEL ENDWALL COLUMN - (SHAPE VARIES) -TAPE SEAL (CONT.) ROOF PANEL /-MEMBER SCREW 8 1/4 1'- 3 1'_11 1/4 0 0 PURLIN (2) 1/2" X 1 IM, BOLTS y ---- FLANGE BRACE MAIN FRAME RAFTER COLUMN CLIP: W/ 5/8" X 1 1/4" A325 BOLTS (SEE ENDWALL ELEVATION FOR CUP PIECE MARK AND QUANTITY OF BOLTS) SECTION THRU RAKE AT MAIN FRAME RAFTER (I - ti 1/4" SET BACK) (BY-PASS ENDWALL) NOTE: TRIM PROFILE MAY VARY. NO. BY CHKD- DATE NOTE: These drawings are intended to depict general installation of item(s) DRAINING NO. >: described above. Some item(s) may hove been omitted for clari U-1 1.0 KG F ty S13A W M 6/4/9 of presentation. Consult your erection manual or additional IS—Sheets for further guidelines and/or clarifications. GIRT DOOR FRAME WALL PANE C-4 WALK DOOR CLIP (WDC) GIRT WALK DOOR ANGLE (YVDA) SHOWN IN DETAIL "B , USED FOR DOOR BRACING ONLY AND I S S NOT REQ'D. IF OPTIONAL GIRT AT 3'-6 IS USED. �L E� ATTACHMENT TO BASE g ANG \450 CONCRETE, BY OTHERS FRAMING ILEVATION 1/2" 'A' 0'-6 ANCHOR BPOLTS FOR 3070 3'_ FOR 6070 6'-0 ANCHOR BOLT PLAN SILL ANGLE DOOR JAMB ALUMINUM THRESHOLD TAMP—INS TAPE SEAL FIELD VIELD OR USE k0 SCREWS DOOR JAMB HEAD TRIM (BFL24) AUP MI �13FI_22) 'Y' GIRT 5CREW (TYP.) '---: DOOR HEADER HEAD TRIM (BFL24) SECT] )N THRU HEADER GIRT FIELD CUT AT JAMB TRIM DETAIL MEMPER S R W (TYP.) DOOR JAMB _��jAMB TRIM WALL PANE�!7� SECTION A F S-6 GIRT WALK DOOR CLIP (V@C) MEMBER SCREW FIELD BEND WALK DOOR ANGLE (WDA) DETAIL "A" DETAIL "B" AT SILL W/SWING--'OUT DOOR AT BRACE (TYP. BOTH JAMBS) PERSONNEL DOORS (WALK DOOR SECTIONS NOTE: WALL PANEL PROFILE MAY VARY NO. BY CHKD- DATE NOTE: These drawings ore intended to depict general installation of item(s) DRA N NO. >: described above. Some item(s) may have been omitted for clarity C 1.0 KG FM 6/4/99 --- of presentation. Consult your erection manual or additional' S—Sheets for further guidelines and/or clarifications. S20 CIR('lJl AP VFKIT ROOI PANI 20-411 OUTER BAND SPRING * LOADED OPEN DAMPER (OPTIONAL) PUR LIN 20" DIA. THROAT ---------- SECTION RAIN GUARD EYE BOLT BIRDSCREEN BRACE CABLE INNER BAND VENT BASE * INCLUDED WITH DAMPER OPTION 2 0 )1 DIAMETER ROUND GRAVITY VENTS NO. BY CHKD. DATE NOTE: These drawings are intended to depict general installation of item DRAVANG NO. (s) described above. Some item(s) may have been omitted for clarity 1.0 KG FM 6/4/99 of presentation. Consult your erection manual or additional S—Sheets for further guidelines and/or clarifications. S56- - . I PARTITON TRIM OOF PANEL (BFLQ. 0 01 0 STI TC AT 12" SCRE W O.C. T MEMBER SCREW MAIN FRAME PURLIN O.S. CLOSURE \-RAKE RAFTER - ANGLE PARTITION PANEL-/ FLANGE BRACE (IF REQ'D) ALL CONNECTION BOLTS ARE - 1/2" X 0'-l" MACH. BOLTS UNLESS NOTED. SECLION THRU ROOF V-3 SIDEWALL PANEL 0 0 0 0 GIRT PARTITION TRIM \_M.F. 'COLUMN (BFL� STITC� W ,, SCREW AT 20 O.C. FLANGE BRACE PARTITION GIRT (AS REQ'D) PARTITION PANEL SECTION THRU SIDEWALL (BY-PASS MAIN FRAME) -STANDARD SECTIONSIOR TRANSVERSE PARTITION (1'-3 SETBACK) NO. BY CHKD. DATE NOTE: These drawings are intended to depict general installation of item(s) DRAIM'NG NO. described above. Some it6m(s) may hove been omitted for clarity 1.0 KG FM 6/4/99 of presentation. Consult your erection manual or additional S—Sheets for further guidelines and/or clarifications. S63 I CORNER- TRIM (M-BFL830) PARTITION PANEL - PARTITION GIRT kNEL IN SECTION THRU SIDEWALL I - R A 4<T_ 7FLUSH MAIN r NOTE: SEE ERECTION DRAWING FOR EXACT SHEETING ALL CONNECTION BOLTS ARE LAYOUTS. C.L. OF FIRST 1/2" X 0'-l" MACH. BOLTS MAJOR RIB VARIES PE UNLESS NOTED. j R PLAN. CORNER -TRIM (M-BFL830) PARTi flON PANEL PARTITION GIRT PANEL )LUMN * SECTION THRU SIDEWALL FB�PAS`Sk�11��_�U�r STANDARD SECTIONS FOR TRANSVERSE PARTITION (I - 3 @ CORNER) NO. BY CHKD. DATE ' NOTE: These drawings ore intended to depict general installation of item(s) >: described above. Some item(s) may have been omitted for clarity DRAWING NO. Lj 1.0 KG FM' 6/4/99 of presentation., Consult your erection manual or additional S—Sheets for further guidelines and/or clarifications. S63B PLAN REVISION Please complete the following information in order to process your submittal. If this form4s not complete, correc and legible. it may cause a delay in processing. -------------- Owner's Name: Received By: Date: A.P. #: Permit #: Time: Contact Phone Number: Purpose otsubmittal: 0 Permit Applicaiioa Data Item 0 Engineering 0 Plan Revision 0 Requested by Building Inspector or Correction Notice - Inspector's Name: XRequested By Plan's Examiner -Examiner's Name: 0 Other: I If you are revising a plan wWch has already been issued, submit two(2) drawings reflecting the revisions for plan review. If engineering is involved in this revision, the engineer must put his requirements on these drawings and stamp and sign the drawings. Include two (2) sets of wet signed engineering. Revised dra clearly sho rO,-inevae r%r^�^e.A -A -2 When Approved, Process as Follows: C3 Mail to Owner at this address: 0 Mail to Contractorat this address: C3 Call 0 Deliver with next inspection and hold for pickup at the 13 Chico Office C1 Oroville Office Revised Plan Check Fee: 0 S46.00 Receipt ft: kAdditional Fees Not Required . Additional. fees may be due based upon complexity and time involved to process this submittal. Additional Fees: Receipt #: 0 0 NON-RESIDENTIAL PLAN REVIEW GUIDE Owner: 9ILL ST -0,j5_- Building Permit Number: 00-02-718 Plans Examiner: A. P. Number: Z 410 - 0 L6 GENF,RAL: tl"' Plans designed and wet stamped by a California licensed architect or registered engineer. Complete Code Analysis provided. 3 Proper description of work on the application. 10" Zoning requirements 6) Land Development approval. 6r' Fire Marshal approval. Environmental Health Department approval 7 (a) . Kitchen (b) Pool (c) H occupancy. Hazardous Materials and Emissions Questionnaire. Building permit valuation. 16' Existing violations on the property. I,'r Recorded notice of violation. PLOT PLAN: X Complete parcel size and dimensions. -2!' Setbacks, side yard, easements, etc. 14-1, Other buildings or structures. 4' Grading, fills and/or drainage. Flood hazard and constructionrequirements. State Responsibility Area review. of plot plan.. 4'." Special conditions on Parcel Map (Noise, Fire Sprinklers, Water Tender, Traffic and Drainage fees). 4.� FAU & FAS road setback. ,9"' Building or utilities across lot lines (record form). OCCUPANCY REQUIREWNTS: ,I- Compliance with specific occupancy requirement. 2�' Mixed Occupancies Ratio (Uniform Building Code section 504.3). -3' Occupancy Separations (Uniform Building Code section 302). A- Area Separations (Uniform Building Code section 504.6). -5'.' Fire walls due to location on property (Uniform Building Code section 503 and Table 5-A). Maximum height requirements (Uniform Building Code section506 and Table 5-B). 7-.- Fire Sprinkler System (Uniform Building -Code section 904). 8�._ Fire alarm system (UBC section 305.9 = E, 307.9 = H-6, 308.9 = I and 3 10. 10 = R-1). 8�� Smoke Control (Uniform Building Code section 905). ljOr'."Attic- Access, Draft Stop and Ventilation (Uniform Building Code section 1505). I'l. Mini m*um Plumbing Facilities (Uniform Plumbing Code Table 4-1). Z. Accessibility for the Physically Disabled (Title 24). ��Commercial Kitchen Grease Hoods (Uniform Mechanical Code section's 507 & 508). (99 National Electrical Code requirements (Medical - Article 517, Assembly -518, Garages - 511, etc.). 0,-Prohibited locations of gas water heaters (Uniform Plumbing Code 509& 1213.5). 6. Prol�iiblted locations of gas heating equipment (Uniform Mechanical Code 304.5). Page I of 2 TYPE OF CONSTRUCTION REQUIREMENTS: Roof pitch for roof covering (Uniform Building Code Table 15 -B -I& 2, 15-D-1 & 2). Roof drainage (Uniform Building Code sectionl506). ,3-' Parapets (Uniform Building Code section 709.4). ,.4' Floors and walls in water closet compartments and showers (Uniforin Building Code section 807). / Guardrails (Uniform Building Code section 509). A"' Attic access and ventilation (Uniform Building Code section 1505). 2," Skylights (Uniform Building Code section 2409 & 2603.7). X Stages and platforms (Uniform Building Code section 405). ,9' Interior Finishes -Flame Spread Classification and Maximum Flame Spread (UBC chapter 8). Fown plastic insulation (Uniform Building Code section 2602). Glazing in Hazardous locations (Uniform Building Code section 2406). MEANS OF EGRESS: 4�_ General egress requirements: ,r-]. The Exit Access (Uniform Building Code section 1004). The Exit (Uniform Building Code section 1005). The Exit Discharge (Uniform Building Code 1006). 2- Number of exits (Uniform Building Code Table 10-A). 4.' Egress width requirements (Uniform Building Code Table 10-B). Stairway details — landings, rise and run, head clearance, handrails (UBC section 1003.3.3). Hallways and Corridors (Uniform Building Code section 1004.3.3 & section 1004.3.4). Maximum travel distance to exits (Uniform Building Code section 1004.2.5.2.1 & 1004.2.5.2.2). -7" Egress requirements based upon occupancy category (Uniform Building Code section 1007). JK Exit signs and illumination (Uniform Building Code 1003.2.8 & 1003.2.9). ,9,., Floor level exit signs in Group R-1 occupancy (Uniform Building Code 1007.6.2). Aisles a nd seat spacing (Uniform Budding Code section 1440.3.2). Doors (Uniform Building Code section 1003.3. 1). MISCELLANEOUS REQUIREMENTS: Brick or stone veneer (Uniform Building. Code section 1403). Energy design compliance and supporting documentation. 3. Special Inspection requirements (Uniform Building Code section 1701): 3. 1. High Strength Bolting. 3.2. Field Welding. 3.3. Masonry (full stress). 3.4. Concrete (f c > 2500 psi). ,e Special Certificates — Mill Certificates. 5. Expansive soil — special foundation design required. IBUH,DING PERMIT REQUIREMENTS: 1. SRA. 6 Flood elevation certificate. 3. Fire Sprinklers required. 4. Special Inspection requirements. 5. Use Permit conditions. 6. Identify Occupancy and Construction Type on the, Application and Permit. Page,2 of 2 0 Department of Development Services Building Division 7 County Center Drive Oroviffe, CA 95965 (530) 538-7541 (530) 538-2140 FAX SINGLE OCCUPANCY CODE ANALYSIS Building Use: CrfA 114 Slo(Z, AGr- Ekc t,- 11- 4 Type of Occupancy - (A –3 Type of Construction - ft -3 -A Basic Allowable Floor Area – UBC Ta��- 0 00 Proposed Floor Area: 5710 0 Maximum Height of Building: Number of stories: Allowed - P_ Proposed - Height in Feet: Allowed - 5-_q 1 Proposed - Z8' Fire Sprinklers: Yes No X_ Allowable area increases (if applicable) Uniform Building Code section 505: Separation on two sides: Minimum yard width > 20' x 1.25% = Allowable increase (50% Max.) x 1.25% Separation on three sides: Minimum yard width > 20'x 2.50% = Allowable increase (100% Max.) x 2.5% Separation on all sides: Minimum yard width > 20' x 5% = Allowable increase (100% Max.) x 5% Automatic Sprinkler System: Allowable area x 3 for one-story buildings. Allowable area x 2 for buildings of more than one-story. Actual Area -- Load factor' = Occupants Exits Required 2 Exits Provided 5100 ' 300 1-7 1 1 Existing Occupant Load (if applicable): Additional Occupant Load: 12 Total Occupant Load: 17 Uniform Building Code 1003.2-2-2. 1: In determining the occup—ant load, allportions of a building shall be presumed to be occupied at the same time. Pagel of2 Uniform Building Code — Table 10-B - Egress width per person served 3 Occupant load x 0.2 = Horizontal exit width required in inches: 3 - Occupant load x 0.3 = Stairway exit width required in inches: Total exit width provided: Maximum travel distance to exits: Non-sprinkled=200': 2S Sprinkled=250': Indicate on the building plans The Exit AcceSS4 , The Exit 5, and The Exit Discharge 6 I- LJBC Table 10 — A- 2- LJBC 1004.2.4 — Where two or more exits are required from any level or portion of the building, at I east two of the exits shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the area served measured in a straight tine between the center of such exits. Additional exits shall be arranged a reasonable distance apart so that if one becomes blocked, the others will be available. 3- Refer to UBC Table 10-B for H-1, H-2. H-3, H-7, 1-1, and 1-2 occupancy requirements for egress width. 4- LJBC 1004. 1: The exit access is that portion of a means of egress system between any occupied point in a building or structure and a door of the exit 5- UBC 1005. 1: The exit is that portion of the means of egress system between the exit access and the exit discharge or the public way. 6- LJBC 1006.1: The exit discharge is that portion of the means of egress system between the exit and the public way. Page 2 of 2 0 1 0 PRC -ECT PROCESSING RF.CORD 0 c-.,- ,-- � , & A 1010T Td" A NV* I ( 6*NER: -. PERNM #: A. P. #: WORK DESCRIM DATE RESCRnMON OF -� 1 -5 - (110 Co 4- :;/7 -73.- 4 le-� ,pop CA�LC5 8- NAME Off �E-Cjb tL T- ^AEFf A-(::) W ILL A L- 1�4Y M C -A-C( S, BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM . (One form per Building) School District Building Department No. A.*P. Number -Off- Jurisdiction: city ;;�C—ou—nty Property Owner smc–f— Property Location/Address 14 Subdivision Lot No. Residential Development Cornmerc6l/Inclustrial I I--," — No of Living Mobile Home Units Installation New Addition i Building De�—artment Representative ........................................................................... : ... ................................... Sq. Footage 5 *Supplemental to (Group R) Addition/ Conversion Permit # *(No foundation inspection):: ................................................................................................................... triocir rians reviewed oy z>cnooi uistrict 'Sq. Footage Date (Including Exterior Roofed Areas) District Identification No. D LO A -v -n -e, School District certifies that (Applicant) 5D 3D rn ?.,j U-) 44 9�;, (Street Address) (Phone. Number) (City) has complied with the requirements of Resolution No. "� 100 representing -m * square feet. School Dist V It hepres ent Paid by Check # Remarks: (State) (Zip Code) by payment of $ N $ Date' Notice: You may protest the imposition of the fees identified above by submitling a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit -you from challenging 4 6e imposition of the fee a i'h any court action. If. sub.sequent to the School District Representat ive signing this gutte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency,that this project is being reviewed under the California Environmental Quality Act (CEQA). this project may be subject to additional school fees to.fully mitigate its impact on the school district's schools. White (applicant), Yellow.(building department), Pink (school district) fee.form.xls 110/98)dmm B E A U T Y ur-rAK i mr-m i ur ucvcL%jrmcn i ocnvis�ra, 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (530) 538-7541 FAX: (530) 538-2140 Re: Building Permit # 00-0298 Expiration Date: 3-24-01 A.P.# 029-240-016 With reference to the above subject, our records indicate that your building permit expires on the above date and your permit falls into one of the category marked below: JX] Permit work started, but not completed.- Permit may be renewed for 1/2 the original building permit fee (plus a $20.00 filing fee). The renewal permit will extend the building permit for an additional year from the original expiration date. Should you not renew your permit within 30 days of the expiration date, all work must cease until a new building permit has been issued. For your convenience, weare enclosing a renewaJ'�pplication form and owner -builder form to be completed and signed by you wfle.'Ckldl-��ted and re"turned to this office together with the fee shown. Please return all Mies of the application form. No inspections have been made on permit work. Inspections are required to verify code compliance. We are unable to renew a permit where the work has not been started and inspected prior to permit expiration. After expiration of your permit, no work may be started until a new permit has been issued. A final inspection has not been made on permit work. Final inspection approval is required before occupancy. Our field inspector has verified that the building is occupied. Occupancy must cease until a final inspection can be made and final approval given. You have 30 days to voluntarily cease occupancy or to present an acceptable plan for abatement or corrective actions to be taken by you. If our records are in error or should you have any questions concerning this matter, please contact the OROVILLE office. Thank you for your prompt attention concerning this matter. Yg.Vrs very truly, C. Vi6ira, C.B.O. -, Building Inspection MCV:1t Attachments CC: SIERRA CASCADE Chico Office - 411 Main Street, Chico / 891-2751 r E DESIGN CALCULATION FOR JOB # 182408 RE: BILL STONE LOC: RICHVALE, CA. BUILDING DESCRIPTION: TYPE SPAN EAVE HEIGHT BUILDING LENGTH ROOFSLOPE BAY SPACING DESIGN LOADS: DEAD LOAD: LIVE LOAD WIND LOAD: OTHERLOADS SEISMIC: "A" CS 60'-0" 25'-0" 85'-0" 1.0/12 VARIES WEIGHT OF METAL BUILDING ONLY 12.0 PSF FRAMES 20.0 PSF PURLINS UBC 1997, 75.0 MPH, EXP. C, 1=1.00 0.00 PSF COLL.; ZONE 3; 1=1.00 S. HO,6 0,1f, fy No 25f?02 10 N(b 40 X"q JOB TITLE - is CRIPTION 3r *d4- 4k K /41 Iv,31 Rgy A3 a JOB NO. QUOTE NO. DESIGNED BY CHK'D la , , 7 DATE 4�" - SHEET NO P./. j L ?�'A &18�131 L� T_ '�5 a/-7 _ /-V" 6V,1.75 ip �10� at �?, 01a; I- 4; ?K 4k K 14, 'K e,opt I i!� -1k 45 -svw -jZ Pj, 04 14) lo: I FRAME )PF- -1: 12 .: -p-T j-0 , axa, * FLANGE BRACES ROOF: h 77141o� JOB NUMBER: 314 b4A- SHEET NO. f S- REV. O.F. WEB I.F. -WLc2 L - SYM. - 3f /I OA.A -P A- BOLT W/,.z,-P-) (LOW EAVE TO HIGH EAVE) )0 x A325 V 1. 1 7IFF WALL (BASE TO EAVE) 4-7 'o e( -Y�)O x A325 W/ P -'s ; k. Job Alumber: 182408AIEGD - 2-4 At Lines: 2-4 . PAGE 3/5 Page: I of I Hor + Ver + FrameReaction Schematic (aff reactions are in kips, I kip 1,000pounds) Moment + Description Grid Ver Hor Moment Description Grid Iler Hor Moment DEAD + LIVE LOAD A 10.387 4.057 0.000 DEAD + LIVE LOAD D 10.387 -4.057 0.000 DL + WLL A -8.474 -9.683 0.000 DL + WLL D -3.383 -3.030 0.000 DL + 1/2LL + WLL A -4.424 -8.034 0.000 DL + 1/2LL + WLL D 0.667 -4.680 0.000 DL W 1/2WLL + LL A 5.007 -1.164 0.000 L + + 1/27WLL + LL D 1 7.552 -5.193 0.000 DL+EQ A 1.886 0.225 0.000 DL+EQ D 2.687 -1.225 0.000 OU07.1999 c:\dsnlib\l 82408a.dso 10-21-29 AM R Job Number: 182408SIEGD - S At Lines: 5 PAGE 4/5 Page. I of I Hor + Ver + FrameReaction Schematic (all reactions are in kips, I kip 1,000pounds) Moment + Description Grid Ver I-lor Moment Description Grid Iler Hor Moment DEAD + UVE LOAD A 6.324 2.434 0.000 DEAD + UVE LOAD D 6.324 -2.434 0.000 DL + VvLL A -7.414 -6.709 0.000 DL + WLL D 4.585 -0.354 0.000 DL + 1/2LL + WLL A -5.164 -5.760 0.000 DL + 1/2LL + WLL D -2.335 -1.304 0.000 DIJL + 111/2 WWLL + LL A 1.705 -1.188 0.000 DL + 1/2W.. LL + LL D 3.120 -2.343 0.000 DL + EQ A 1.624 0.268 0.000 DL+EQ D 2.025 -0.768 0.000 Oct 07.1999 c:\dsnhb\182408b.dso 10:21:�7 AM '5- or ilding Load Sheet Job Number If 2 �4� It is the responsibility of the Contractor to confirm that these loads comply with the requirements of the local building department. Design Code (Code and Edition) Roof Dead Load 0, (psf) Collateral Dead Load (psf) Auxiliary Live Load (Psf) Roof Live Load Primary Framing I -Z, (psf) Secondary Framing 1�0 (p sf) Snow Load (psf) Roof- Ground - Ce Wind Load (mph) -(A Exposure 1 Seismic Load Zone Av Aa Seismic Hazard Exposure Group Seismic Performance Category Site Coefficient C41 i Dual system with ordinary Basic Structural System moment frames of steel & conc tricall braced frames. Response Modification Factor (R)-= - A--�' Deflection Amplification Factor (Cd)x 4 ral Force Analysis -Procedure Equivalent Late, Importance Factors Wind Load Snow Load Seismic Load J-; 0 er e Loads� (psi) Dead Load (psf) Live Load M� ' 7. Crane Loads 0 Y & Capacity & Type Wheel Load idge Weight Wheel Base Hoist Weight la`ls-� Special Loads 0 . X JOB No. JOB TITLE QUOTE NO CRIPTION DESIGNED BY- CHK'D BY DATE - SHEET NO. IS--r7d PZr -g7 -s- �-IIIS72�) /.,::p 67 3! f 7 S, sx 01400 Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 PURLIN DESIGN *** 8 E *** GEOMETRIC DATA *** JOB NUMBER : 182408 ( FULL OPTIMIZATION BAY SPACING (FEET) :3@20.,25. INSET LEFT (FEET) .667 INSET RIGHT (FEET) .333 PURLIN EXTN LEFT (FT.): .00000 PURLIN EXTN RIGHT (FT..) .00000 ROOF SLOPE :1.000/12 HORIZONTAL SPACING (FT.): 5A0000 PURLIN DEPTH (INCH) : 8.00 TOP FLANGE BRACED AT 1.00 FEET *** DESIGN CRITERIA *** DEAD LOAD (PSF) 2.00 LIVE LOAD (PSF): 20.00 WIND VELOCITY PRESSURE (q): 17.386 PSF SPECIAL. WIND COEFF.: -1.10 MAX. COMBINED SHEAR AND BENDING UNITY CHECK :1.035 MAX. SHEAR OR BENDING UNITY CHECK :1.035 MAX. DEFLECTION LIMIT PER SPAN : L/180. LOADING COMBINATION 1 . DL+LL 2. DL+WL 3. DL+0.5LL+WL 4. DL+LL+0.5WL *** CRITICAL ROW SUMMARY *** id SPAN ANALYSIS LAP SIZE OF LAP WIND DL + WL DL + LL # ---- LENGTH LEFT SECTION RIGHT COEF (KLF) (KLF) 1 -------- .6667 ------ .0000 ------- 8Z16 ------- .0000 ------- -1.1000 ------- -.0860 ------- .1096 2 19.3333 .0000 8Z16 1.2291 -1.1000 -.0860 .1096 3 20.0000 1.2291 8Z16 1.2291 -1.1000 -.0860 .1096 4 20.0000 1.2291 8Z16 2.4791 -1.1000 -.0860 .1096 5 24.6666 1.2291 8Z13 .0000 -1.1000 -.0860 .1096 6 .3334 .0000 8Z13 .0000 -1.1000 -.0860 .1096 E 0 0 601 FLANGE BRACE INFORMATION NOLENGTH OUTSIDE INSIDE NO (FT.) BRACES BRACES .667 1@.6667, 1@.6667 2 19.333 20@1.0000 1@19.3333 3 20.000 20@1.0000 1@20.0000 4 20.000 20@1.0000 1@20.0000 5 24.667 25@1.0000 1@24.6666 6 .333 1@.3334 1@.3334 0 0 601 *** PURLIN DESIGN *** JOB NAME: 182408 LOADING COMBINATION -- DL+LL PAGE 2 -------------------------------------------------------------------------- k so 0 !MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS DEFL U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! 4.97 2.28 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 .00 .00 .00 .00! 0 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! ------------------------------------------------------------------------------- -.02! -.07! 4.97 2.28 .03 -00 .00! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -.02! .82! 4.97 2.28 .36 .00 .13! !LL! .00! .00! .00 .00 .00 .00 .00! 2!FM! 3.07! .00! 4.97 2.28 .00 .62 .62! 334 !RL! -3.07! -1.16! 4.97 2.28 .51 .62 .64! !RS! ------------------------------------------------------------------------------- -4.58! -1.30! 9.94 4.57 .28 .46 .29! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES ' ! UNITY CHECKS I ! DEFL ! U ------------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) ! SHEAR BEND COMB! -L/- !LS! -4.58! 1.18! 9.94 4.57 .26 .46 .28! !LL! -3.21! 1.05! 4.97 2.28 .46 .65 .63! 3!FM! 1.81! .00! 4.97 2.28 .00 .37 .37! 735 * -1.67! -.87! 4.97 2.28 .38 .34 .26! - -2.82! ------ -1.01! 9.94 4.57 .22 28 13! SP!LO!MOMENT! ------ SHEAR! ---- ALLOWABLE ---- FORCES --- UNITY --- CHECKS ---- ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -2.82! .94! 9.94 4.57 .20 .28 .12! !LL! -1.76! .80! 4.97 2.28 .35 .35 .25! 4!FM! 1.17! .00! 4.97 2.28 .00 .23 .23! 4778 !RL! -3.27! -.99! 4.50 2.28 .43 .73 .71! !RS! ------------------------------------------------------------------------------- -6.04! -1.26! 12.72 9.16 .14 .48 .24! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -6.04! 1.60! 12.72 9.16 .17 .48 .26! !LL! -4.16! 1.46! 7.75 6.88 .21 .54 .33! 5!FM! 5.59! .00! 7.75 6.88 .00 .72 .72! 187 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! -------------------------------------------------------------------------- -.01! -1.11! 7.75 6.88 .16 .00 .03! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U ---------------------------------------------------------------------------- K -FT! KIP ! . MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! -.01! .04! 7.75 6.88 .01 .00 .00! 7 -- !LL! .00! .00! .00 .00 .00 .00 .00! 61FM! .00! .00! .00 .00 0 .00 .00 .00! *L! .00! .00! .00 .00 .00 .00 .00! S! .00! .00! .00 .00 .00 .00 .00! PURLIN DESIGN JOB NAME: 182408 PAGE 3 LOADING COMBINATION -- DL+WL 11 - -------- - ------ ----- --------- - ------ ----- ------- ----- - ------ --- S*PO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS---- DEFL U K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! 6.63 3.05 .00 . 00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 .00 .00 .00 .00! 0 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .02! .06! 6.63 3.05 .02 .-oo .00! ------------------------------------------------------------------ SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ------------ ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .02! -.65! 6.63- 3.05 .21 .00 .05! !LL! .00! .00! .00 .00 .00 .00 .00! 2!FM! -2.41! .00! 4.64 3.05 .00 .52 .00! 426 !RL! 2.41! .91! 6.63 3.05 .30 .36 .22! !RS! ------------------------------------------------------------------------------- 3.59! 1.02! 13.25 6.09 .22 .27 .12! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 3.59! -.93! 13.25 6.09 .20 .27 .11! !LL! 2.52! -.82! 6.63 3.05 .27 .38 .22! 3!FM! -1.42! .00! 4.64 3.05 .00 .31 .00! 937 L! 1.31! .69! 6.63 3.05 .22 .20 .09! S! 2.22! .79! 13.25 6.09 .17 .17 .06! --------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 2.22! -.73! 13.25 6.09 .16 .17 .05! !LL! 1.38! -.63! 6.63 3.05 .21 .21 .09! 4!FM! -.91! .00! 4.64 3.05 .00 ..20 .00! 6090 !RL! 2.56! .77! 6.63 3.05 .25 .39 .21! !RS! 4.74! .99! 16.96 12.22 .11 .28 .09! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 4.74! -1.25! 16.96 12.22 .14 .28 .10! !LL! 3.27! -1.15! 10.33 9.17 .13 .32 .12! 5!FM! -4.38! .00! 7.23 9.17 .00 .61 .00! 239 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .00! .87! 10.33 9.17 .09 .00 .01! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT!. KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.03! 10.33 9.17 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! .00! .00! .00 .00 .00 .00 .00! 0 Jk'Fm! L! .00! .00! .00 .00 .00 .00 .00! S! .00! .00! .00 .00 .00 .00 .00! PURLIN DESIGN JOB NAME: 182408 PAGE 4 12 LOADING COMBINATION -- DL+0.5LL+WL -w -------------------------------------------------------------------------- S O!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! 6.63 3.05 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 .00 .00 .00 .00! 0 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .01! ------------------------------------------------------------------ .02! 6.63 3.05 .01 ..00 .00! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ------------ ! DEFL ! U K -FT! ------------------------------------------------------------------------------- KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! .01! -.27! 6.63 3.05 .09 .00 .01! !LL! .00! .00! .00 .00 .00 .00 .00! 2!FM! -1.01! .00! 4.64 3.05 .00 .22 .00! 1013 !RL! 1.01! .38! 6'.63 3.05 .13 .15 .04! !RS! 1.51! ------------------------------------------------------------------------------- ..43! 13.25 6.09 .09 .11 .02! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! ------------------------------------------------------------------------------- KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! 1.51! -.39! 13.25 6.09 .09 .11 .02! !LL! 1.06! -.35! 6.63 3.05 .11 .16 .04! 3!FM! -.60! .00! 4.64 3.05 .00 .13 .00! 2226 L! .54! .29! 6.63 3.05 .09 .08 .02! S! .93! ---------------------------------------------------------------------------- .33! 13.25 6.09 .07 .07 .01! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- -------------- !LS! .93! 7 ---------------------------------------------------------------- -.31! 13.25 6.09 .07 .07 .01! !LL! .58! -.26! 6.63 3.05 .09 .09 .02! 4!FM! -.38! .00! 4.64 3.05 .00 .08 .00! 9999 !RL! 1.07! .32! 6.63 3.05 .11 .16 .04! !RS! 2.00! ---------------- .42! 16.96 12.22 .05, .12 .02! SP!LO!MOMENT! ---------------------------------------------------------------- SHEAR! ALLOWABLE FORCES I UNITY CHECKS DEFL U K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 2.00! -.53! 16.96 12.22 .06 .12 .02! !LL! 1.38! -.48! 10.33 9.17 .05 .13 .02! 5!FM! -1.84! .00! 7.23 9.17 .00 .25 .00! 569 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .00! ------------------------------------------------------------------------------- .37! 10.33 9.17 .04 .00 .00! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! ------------------------------------------------------------------------------- KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! .00! -.01! 10.33 9.17 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! .00! .00! .00 .00 .00 .00 .00! 0 *FM! L! .00! .00! .00 .00 .00 .00 .00! S! .00! .00! .00 .00 .00 .00 .00! PURLIN DESIGN JOB NAME: 182408 PAGE 5 LOADING COMBINATION DL+LL+0.5WL -S*O-!-M-O-ME-N--T-!-S-H--E-A-R-! ------ ------ ------- --- --FL- --- AL-L-0-WA-B-L-E---F0-R-C-E--S ! U-N--IT-Y--C-H-E-C-K--S---- ! DE ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) ! SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! 6.63 3.05 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 .00 .00 .00 .00! 0 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! -.01! -.04! 6.63 3.05 .01 ..00 .00! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -.01! .46! 6.63 3.05 .15 .00 .02! !LL! .00! .00! .00 .00 .00 .00 .00! 2!FM! 1.73! .00! 6.63 3.05 .00 .26 .26! 595 !RL! -1.73! -.65! 6.63 3.05 .21 .26 .11! !RS! -2.57! -.73! 13.25 6.09 .16 .19 .06! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -2.57! .67! 13.25 6.09 .15 .19 .06! !LL! -1.80! .59! 6.62 3.05 .19 .27 .11! 3!FM! 1.02! .00! 6.63 3.05 .00 .15 .15! 1308 L! -.95! -.49! 6.63 3.05 .16 .14 .05! S! -1.59! -.57! 13.25 6.09 .12 .12 .03! _0 ---------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND . COD4B! -L/- ------------------------------------------------------------------------------- !LS! -1.59! .53! 13.25 6.09 .12 .12 .03! !LL! -.99! .45! 6.63 3.05 .15 .15 .04! 4!FM! .66! .00! 6.63 3.05 .00 .10 .10! 8502 !RL! -1.84! -.55! 6.00 3.05 .18 .31 .13! !RS! -3.40! -.71! 16.96 12.22 .08 .20 .05! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS !'DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -3.40! .90! 16.96 12.22 .10 .20 .05! !LL! -2.34! .82! 10.33 9.17 .09 .23 .06! 5!FM! 3.14! .00! 10.33 9.17 .00 .30 .3b! 334 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .00! -.62! 10.33 9.17 .07 .00 .00! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .02! 10.33 9.17 .00 .00 .00! !LL! .00! .00! .00 .00 .00 .00 .00! .00! .00! .00 .00 .00 .00 .00! 0 101FM! L! .00! .00! .00 .00 .00 .00 .00! S! .00! .00! .00 .00 .00 .00 .00! Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 EAVE STRUT DESIGN JOB NUMBER : 182408 ( FULL OPTIMIZATION *** GEOMETRIC DATA *** BAY SPACING (FEET) :3@20.,25. BAY SPACING (FEET) INSET LEFT (FEET) .6670 INSET RIGHT (FEET .3330 EAVE EXTN LEFT (FT.) .0000 EAVE EXTN RIGHT (FT.) .0000 ROOF SLOPE NAME ------- :1.000/12 HORIZONTAL SPACING (FT.) :-2.5000 EAVE STRUT DEPTH (INCH) : 8.00 TOP FLANGE BRACED AT 1.00 FEET *** DESIGN CRITERIA *** DEAD LOAD (PSF) : 2.000 LIVE LOAD (PSF):20.000 WIND VELOCITY PRESSURE (q): 17-.386 PSF SPECIAL WIND COEFF.:-1.833 MAX. COMBINED SHEAR AND BENDING UNITY CHECK :1.030 MAX. SHEAR OR BENDING UNITY CHECK :1.030 MAX. DEFLECTION LIMIT PER SPAN L/100. 14 Ste LENGTH SECTION AREA MOMENT WIND DL + WL DL + LL ---- -FT- ------- NAME ------- IN.SQ. ------- INERTIA ------- COEF (KLF) (KLF) 1 .67 8ES14 1.256 12.92 ------- -1.8330 ------- -.0750 ------- .0548 2 19.33 8ES14 1.256 12.92 -1.8330 -.0750 .0548 3 20.00 8ES14 1.256 12.92 -1.8330 -.0750 .0548 4 20.00 8ES14 1.256 12.92 -1.8330 -.0750 .0548 5 24.67 8ES12 1.883 19.14 -1.8330 -.0750 .0548 6 .33 8ES12 1.883 19.14 -1.8330 -.0750 .0548 14 *** EAVE STRUT DESIGN *** JOB NAME: 182408 PAGE 2 15 **** DEAD + LIVE LOAD ------ ------ --------- --- --FL- --- S*'O-!M--OM--EN-T--!-S--H-E-A-R! A-L--LO-W-A-B-L-E---F0-R-C-E-S ! UN--IT-Y--C-H-E-C-K--S---- ! DE ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) ! SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 * 00 .00 .00 .00! -161 RS! -.01! .04! 6.96 3.58 .01 .00 .01! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY.CHECKS ! DEFL U ------------------------------------------------------------------------------- K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! -.01! .53! 6.96 3.58 .15 .00 .15! 2!FM! 2.55! .00! 6.95 3.58 .00 .37 .37! -514 RS! ------------------------------------------------------------------------------- .00! -.53! 6.96 3.58 .15 .00 .15! SP!LO!MOMENT! SHEAR! . ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .55! 6.95 3.58 .15. .00 .151 3!'PM! 2.74! .00! 6.95 3.58 .00 .39 .39! -463 RS! ------------------------------------------------------------------------------- .00! -.55! 6.95 3.58 .15 .00 .15! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- ILS! .00! .55! 6.95 3.58 .15 .00 .15! OM! 2.74! .00! 6.95 3.58 .00 .39 .39! -463 S! -------------------------------------------------------------------------------- .00! -.55! 6.95 3.58 .15 .00 .15! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .68! 11.37 19.15 .04 .00 .04! 5!FM! 4.17! .00! 11.36 19.15 .00 .37 .37! -366 RS! .00! -.68! 11.37 19.15 .04 .00 .04! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.02! 11.38 19.15 .00 .00 .00! 6!FM! .00! .00! .00 .00 .00 .00 .00! -114 RS! .00! .00! .00 .00 .00 .00 .00! *** EAVE STRUT DESIGN *** JOB NAME: 182408 PAGE 3 16 DEAD + WIND LOAD So-------------------------------------------------------------------------- P. 0 !MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .00! .00 .00 .00 .00 .00! 1!FM! .00! .00! .00 ' 00 .00 .00 .00! 117 RS! .02! -.05! 9.28 4.77 .01 .00 .01! ------------------------------------------------------------------------------- SP!LO!MOMENT! 'SHEAR! ALLOWABLE FORCES UNITY -CHECKS ! DEFL ! U ------------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) - SHEAR(Va) SHEAR BEND COMB! -L/- !LS! .02! -.73! 9.28 4.77 .20 .00 .20! 2!FM! -3.49! .00! 3.73 4.77 .00 .94 .94! '376 RS! ------------------------------------------------------------------------------- .00! .72! 9.28 4.77 .20 .00 .20! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL #! K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.75! 9.27 4.77 .21 .00 .21! 3!FM! -3.75! .00! -3.72 4.77 .00 1.01 1.01! 339 RS! .00! .75! 9.27 4.77 .21 .00 .21! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- ! , 00! -.75! 9.27 4.77 .21 .00 .21! I*S -3.75! .00! 3.72 4.77 .00 1.01 1.01! 339 S s .00! .75! 9.27 4.77 .21 .00 .21! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.92! 15.15 25.54 .05 .00 .05! 5!FM! -5.70! .00! 6.07 25.54 .00 .94 .94! 267 RS! .00! .92! 15.15 25.54 .05 .00 .05! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .02! 15.17 25.54 .00 .00 .00! 6!FM! .00! .00! .00 .00 .00 .00 .00! 83 RS! .00! .00! .00 .0,0 .00 .00 .00! Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 GIRT DESIGN 17 FRONT SIDEWALL JOB NUMBER : 182408 ( FULL OPTIMIZATION *** GEOMETRIC DATA *** BAY SPACING (FEET) :3@20.,25. INSET LEFT (FEET) .6667 INSET RIGHT (FEET) .3333 ROOF SLOPE 1.00112 MAX. TRIBUTARY SPACING.(FT.) 6.6458 GIRT DEPTH (INCH) 8.00 GIRT CONDITION . :BY -FRAME OUTSIDE FLANGE BRACED AT 1.00 FEET *** DESIGN CRITERIA *** WIND VELOCITY PRESSURE (q): -17.39 PSF WIND LOAD PRESSURE COEFF. : '1.00 WIND LOAD SUCTION COEFF. 1.00 MAX. COMBINED SHEAR AND BENDING UNITY CHECK 1.03 MAX. SHEAR OR BENDING UNITY CHECK 1.03 MAX. DEFLECTION LIMIT PER SPAN :L/ 90. AN BAY MAX PRESSURE SUCTION PRESSURE SUCTION 0. -- SPACING ------- TRIB SPA -------- COEF -------- COEF ------- (KLF) -------- (KLF) 1 19.3333 6.6458 1.0000 -1.0000 .1155 ------- -.1155 2 20.0000 6.6458 1.0000 -1.0000 .1155 -.1155 3 20.0000 6.6458 1.0000 -1.0000 .1155 -.1155 4 24.6667 6.6458 1.0000 -1.0000 .1155 -.1155 LOADING COMBINATION 1. WLP 2. WLS *** CRITICAL ROW SUMMARY *** SPAN ANALYSIS LAP SIZE OF LAP # ---- LENGTH LEFT SECTION RIGHT 1 -------- 19.3333 ------ .0000 ------- 8Z16 ------ 1.2291 2 20.0000 1.2291 8Z16 1.2291 3 20.0000 1.2291 8Z16 1.2291 4 24.61667 1.2291 8Z14 .0000 FLANGE BRACE INFORMATION 0 E INSIDE BRACES 1@20. 0000 1@20. 0000 1@20 . 0000 1@25. 0000 NOLENGTH OUTSIDE NO (FT.) BRACES 19.333 20@1.0000 2 20.000 20@1.0000 3 20.000 20@1.0000 4 24.667 25@1.0000 0 E INSIDE BRACES 1@20. 0000 1@20. 0000 1@20 . 0000 1@25. 0000 GIRT DESIGN JOB NAME: 182408 FRONT SIDEWALL PAGE,2, 19 L&NG COMBINATION -- WLP SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .87! 6.63 3.05 .28 .00 .08! !LL! .00! .00! .00 .00 .00 .-oo .00! 1!FM! 3.25! .00! 6.63 3.05 .00 .49 .49! 317 !RL! -3.26! -1.23! 6.63 3.05 .40 ..49 .40! !RS! -4.85! -1.37! 13.25 6.09 .30 .37 .22! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -4.85! 1.25! 13.25 6.09 .27 .37 .21! !LL! -3.40! 1.11! 6.62 3.05 .36 .51 .40! 2!FM! 1.94! .00! 6.63 3.05 .00 .29 .29! 682 !RL! -1.71! -.92! 6.63 3.05 .30 .26 .16! !RS! -2.91! -1.06! 13.25 6.09 .23 .22 .10! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -2.91! .97! 13.25 6.09 .21 .22 .09! !LL! -1.81! .83! 6.63 3.05 .27 .27 .15! M! 1.17! .00! 6.63 3.05 .00 .18 .18! 9999 L! -5.05! -1.20! 5.90 3.05 .39 .86 .89! RS! -6.60! -1.34! 14.73 8.15 .22 .45 .25! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- --------------------------------------------------- !LS! -6.60!* 1.69! 14.73 8.15 --------------------------- .28 .45 .28! !LL! -4.61! 1.55! 8.10 5.10 .30 .57 .42! 4!FM! 5.80! .00,!.. 8.10 5.10 .00 .72 .72! 151 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .00! -1.16! 8.10 5.10 .23 .00 .05! 0 0 GIRT DESIGN FRONT SIDEWALL JOB NAME: 182408 PAGE 3 2-0 LO ING COMBINATI . ON -- WLS --------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL U K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.87! 6.63 3.05 .28 .00 .08! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! -3.25! .00! 4.64 3.05 .00 .70 .00! 317 !RL! 3.26! 1.23! 6.63 3.05 .40 ..49 .40! !RS! ------------------------------------------------------------------------------- 4.85! 1.37! 13.25 6.09 .30 37 .22! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 4.85! -1.25! 13.25 6.09 .27 .37 .21! !LL! 3.40! -1.11! 6.63 3.05 .36 .51 .40! 2!FM! -1.94! .00! 4.64 3.05 .00 .42 .00! 682 !RL! 1.71! .92! 6.63 3.05 .30 .26 .16! !RS! ------------------------------------------------------------------------------- 2.91! 1.06! 13.25 6.09 .23 .22 .10! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 2.91! -.97! 13.25 6.09 .21 .22 .09! !LL! 1.81! -.83! 6.63 3.05 .27 .27 .15! 31 1 Ms! -1.17! .00! 4.64 3.05 .00 .25 .00! 9999 * 5.05! 1.20! 6.63 3.05 .39 .76 .73! 6.60! 1.34! 14.73 8.15 .22 .45 .25! -------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U ------------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! 6.60! -1.69! 14.73 8.15 .28 .45 .28! !LL! 4.61! -1.55! 8.10 5.10 .30 .57 .42! 4!FM! -5.80! .00! 5.67 5.10 .00 1.02 .00! 151 !RL! .00! .00! .00 .00 .00 .00 .00! !RS! .00! 1.16! .8.10 5.10 .23 .00 .05! 0 Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 GIRT DESIGN 2 1 LEFT ENDWALL JOB NUMBER : 182408 ( FULL OPTIMIZATION *** GEOMETRIC DATA *** BAY SPACING (FEET) :3@20.000 INSET LEFT (FEET) .3333 INSET RIGHT (FEET) .3333 ROOF SLOPE .00/12 MAX. TRIBUTARY SPACING.(FT.) 6.7707 GIRT DEPTH (INCH) 8.00 GIRT CONDITION . :BY -FRAME OUTSIDE FLANGE BRACED AT 1.00 FEET *** DESIGN CRITERIA *** WIND VELOCITY PRESSURE (q): -17.39 PSF WIND LOAD PRESSURE COEFF. : 1.00 WIND LOAD SUCTION COEFF. 1.00 MAX. COMBINED SHEAR AND BENDING UNITY CHECK 1.03 MAX. SHEAR OR BENDING UNITY CHECK 1.03 MAX. DEFLECTION LIMIT PER SPAN :L/ 90. AN BAY MAX PRESSURE SUCTION PRESSURE SUCTION 0. SPACING TRIB SPA ------- COEF -------- COEF ------- (KLF) -------- (KLF) 1 19.6667 7 6.7707 1.0000 -1.0000 .1177 ------- -.1177 2 20.0000 6.7707 1.0000 -1.0000 .1177 -.1177 3 19.6667 6.7707 1.0000 -1.0000 .1177 -.1177 *** LOADING COMBINATION *** 1 . WLP 2. WLS *** CRITICAL ROW SUMMARY *** SPAN ANALYSIS LAP SIZE OF LAP - # LENGTH LEFT SECTION RIGHT ---- 1 -------- 19.6667 ------ .0000 ------- 8Z16 ------ 1.2291 2 20.0000 1.2291 8Z16 1.2291 3 19.6667 1.2291 8Z16 .0000 E FLANGE BRACE INFORMATION 2-9- NOLENGTH OUTSIDE NO (FT.) BRACES 19.667 20@1.0000 2 20.000 20@1.0000 3 19.667 20@1.0000 0 INSIDE BRACES 1@20 0000 1@20 0000 1@20. 0000 E GIRT DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 2 23 LfNG COMBINATION -- WLP ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! C K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .92! 6.63 3.05 .30 .00 .09! !LL! .00! .00! .00 .00 .00 .00 .00! 1!FM! 3'.61! .00! 6.63 3.05 .00 .55 .55! 266 !RL! -3.00! -1.25! 6.63 3.05 .41 ..45 .37! !RS! ------------------------------------------------------------------------------- -4.62! -1.39! 13.25 6.09 .30 .35 ..21! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! C K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -4.62! 1.18! 13.25 6.09 .26 .35 .19! !LL! -3.27! 1.03! 6.53 3.05 .34 .50 .37! 2!FM! 1.26! .00! 6.63 3.05 .00 .19 .19! 2262 !RL! -3.27! -1.03! 6.53 3.05 .34 .50 .37! !RS! ------------------------------------- -4.62! -1.18! 13.25 6.09 m .26 .35 .19! SP!LO!MOMENT! SHEAR! ALLOWABLE ------------------------------------------- FORCES UNITY CHECKS ! DEFL ! C ------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! -4.62! 1.39! 7 ----------------------------------------------------- 13.25 6.09 .30 .35 .21! !LL! -3.00! 1.25! 6.63 3.05 .41 .45 .37! M! ms! 3.61! .00! 6.63 3.05 .00 .55 .55! 266 0 .00! .00! .00 .00 .00 .00 .00! .00! -.92! 6.63 3.05 .30 .00 .09! E 0 GIRT DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 3 24 LOA.DTNG ---------------------------------------------------------------------------- COMBINATION -- WLS -41 SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL U K -FT!' KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.92! 6.63 3.05 .30 .00 .09! !LL! .00! .00! .00 .00 .00, .00 .00! 1!FM! -3.61! .00! 4.64 3.05 .00 .78 .00! 266 !RL! 3.00! 1.25! 6.63 3.05 .41 .45 .37! !RS! ------------------------------------------------------------------------------- 4.62! 1.39! 13.25 6.09 .30 .35 ..21! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! 4.62! -1.18! 13.25 6.09 .26 .35 .19! !LL! 3.27! -1.03! 6.63 3.05 .34 .49 .36! 2!FM! -1.26! .00! 4.64 3.05 .00 .27 .00! 2262 !RL! 3.27! 1.03! 6.63 3.05 .34 .49 .36! !RS! ------------------------------------------------------------------------------- 4.62! 1.18! 13.25 6.09 .26 .35 .19! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U ----------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! 4.62! -1.39! 13.25 6.09 .30 .35 .21! !LL! 3.00! -1.25! 6.63 3.05 .41 .45 .37! -3.61! .00! 4.64 3.05 .00 .78 .00! 266 *FM! L! .00! .00! .00 .00 .00 .00 .00! S! .00! .92! 6.63 3.05 .30 .00 .09! 0 Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 GIRT DESIGN RIGHT ENDWALL JOB NUMBER : 182408 ( FULL OPTIMIZATION *** GEOMETRIC DATA *** BAY SPACING (FEET) :3@20.000 INSET LEFT (FEET) .3333 ROOF SLOPE 40AN - 0. .00/12 GIRT DEPTH (INCH) 8.00 OUTSIDE FLANGE BRACED AT 1.00 FEET *** DESIGN CRITERIA *** INSET RIGHT (FEET) : .3333 MAX. TRIBUTARY SPACING -(FT.) : 6.7707 GIRT CONDITION . :BY -FRAME WIND VELOCITY PRESSURE (q): -17.39 PSF WIND LOAD PRESSURE COEFF. : 1.00 WIND LOAD SUCTION COEFF. 1.00 MAX. COMBINED SHEAR AND BENDING UNITY CHECK 1.03 MAX. SHEAR OR BENDING UNITY CHECK 1.03 MAX. DEFLECTION LIMIT PER SPAN :L/ 90. *** CRITICAL ROW SUMMARY *** SPAN BAY MAX PRESSURE SUCTION PRESSURE SUCTION 40AN - 0. SPACING ------- TRIB SPA ---- --- COEF ---- COEF ---- (KLF) ----- (KLF) 1 19.6667 6.7707 1.0000 -1.0000 .1177 ----- -.1177 2 20.0000 6.7707 1.0000 -1.0000 .1177 -.1177 3 19.6667 6.7707 1.0000 -1.0000 .1177 -.1177 LOADING COMBINATION 1. WLP 2. WLS *** CRITICAL ROW SUMMARY *** SPAN ANALYSIS LAP SIZE OF LAP # LENGTH LEFT SECTION RIGHT ---- 1 -------- 19.6667 ------ .0000 ------- 8Z16 ------ 1.2291 2 20.0000 1.2291 8Z16 1.2291 3 19.6667 1.2291 8Z16 .0000 �m 25 *** FLANGE BRACE INFORMATION *** 26 s NOLENGTH OUTSIDE NO (FT.) 0 BRACES 19.667 20@1.0000 2 20.000 20@1.0000 3 19.667 20@1.0000 0 is INSIDE BRACES 1@20. 0000 1@20. 0000 1@20. 0000 GIRT DESIGN RIGHT ENDWALL JOB NAME: 182408 PAGE.2 27 Lo ING COMBINATION -- WLP SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! .92! 6.63 3.05 .30 .00 .09! !LL! .00! - .00! .00 .00 .00 .00 .00! 1!FM! 3.61! .00! 6.63 3.05 .00 .55 .55! 266 !RL! -3.00! -1.25! 6.63 3.05 .41 ..45 .37! !RS! -4.62! -1.39! 13.25 6.09 .30 .35 ..21! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL #! K -FT! KIP MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! -4.62! 1.18! 13.25 6.09 .26 .35 .19! !LL! -3.27! 1.03! 6.53 3.05 .34 .50 .37! 2!FM! 1.26! .00! 6.63 3.05 .00 .19 .19! 2262 !RL! -3.27! -1.03! 6.53 3.05 .34 .50 .37! !RS! -4.62! -1.18! 13.25 6.09 .26 .35 .19! ------------------------------------------------------------------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------ !LS! -4.62! 1.39! 13.25 6.09 .30 7 ------------------ .35 .21! !LL! -3.00! 1.25! 6.63 3.05 .41 .45 .37! 3.61! .00! 6.63 3.05 .00 .55 .55! 266 Jk'FM! L! .00! .00! .00 .00 .00 .00 .00! S! .00! .92! 6.63 3.05 .30 .00 .09! GIRT DESIGN RIGHT ENDWALL JOB NAME: 182408 PAGE 3 28 LOADING COMBINATION -- WLS -9- ----------------------- SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! #! K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- ------------------------------------------------------------------------------- !LS! .00! -.92! 6.63 3.05 .30 .00 .09! !LL! .00! 00! .00 .00 .00 .00 .00! 1!FM! -3.61! .00! 4.64 3.05 .00 .78 .00! 266 !RL! 3.00! 1.25! 6.63 3.05 .41 .45 .37! !RS! ------------------------------------------------------------------------------- 4.62! 1.39! 13.25 6.09 .30 .35 ..21! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U ------------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! 4.62! -1.18! 13.25 6.09 .26 .35 .19! !LL! 3.27! -1.03! 6.63 3.05 .34 .49 .36! 2!FM! -1.26! .00! 4.64 3.05 .00 .27 .00! 2262 !RL! 3.27! 1.03! 6.63 3.05 .34 .49 .36! !RS! ------------------------------------------------------------------------------- 4.62! 1.18! 13.25 6.09 .26 .35 .19! SP!LO!MOMENT! SHEAR! ALLOWABLE FORCES UNITY CHECKS ! DEFL ! U ------------------------------------------------------------------------------- K -FT! KIP ! MOMENT(Ma) SHEAR(Va) SHEAR BEND COMB! -L/- !LS! 4.62! -1.39! 13.25 6.09 .30 .35 .21! !LL! 3.00! -1.25!' 6.63 3.05 .41 .45 .37! 31FM! -L! -3.61! .00! 4.64 3.05 266 .00 .78 .00! O .00! .00! .00 .00 .00 .00 .00! S! .00! .92! 6.63 3.05 .30 .00 .09! Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC PAGE 1 ENDWALL DESIGN LEFT ENDWALL ENDWALL RAFTER JOB NUMBER : 182408 ( FULL OPTIMIZATION *** GEOMETRIC DATA *** ENDWALL COLUMN SPACING: 3@20.000 ENDWALL COLUMN SPACING: ENDBAY (FEET) :20.0000 FRONT SIDE CANOPY (FT): .0000 FRONT SIDE ROOF SLOPE 1.00/12 PURLIN SPACING (FEET) 5.017 *** DESIGN CRITERIA *** PURLIN EXTN. (FEET) -.0000 BACK SIDE CANOPY (FT) .0000 BACK SIDE ROOF SLOPE 1.00/12 DEAD LOAD (PSF) 3.000 LIVE LOAD (PSF) 12.000 WIND VELOCITY PRESS(q): 17.390 PSF BUILDING CONDITION (E,P,O): E SPCL. GCp @ ENDBAY/2 : .000 SPCL. GCp @ OVERHANG -1.000 SHEAR OR BENDING LIMIT: 1.035 RAFTER DEFLECTION LIMIT L/150. OH LOADING COMBINATION 10.0000 .0000 .0000 1, DL+LL 2. DL+WL ------- .0299 ------- .1495 1 3. DL+0.5LL+WL 10.0000 .0000 .0000 4. DL+LL+0.5WL .0299 .1495 *** LOADING *** E 29 ANALYSIS GCp PURLIN GCpX DL+WL DL+LL SPAN ------ LENGTH -------- ENDBAY/2 -------- COEF. ------- EXTN. ------ COEF. ------- (KLF) (KLF) OH 1.0035 10.0000 .0000 .0000 -1.0000 ------- .0299 ------- .1495 1 19.0659 10.0000 .0000 .0000 -1.0000 .0299 .1495 2 20.0693 10.0000 .0000 .0000 -1.0000 .0299 .1495 3 19.0659 10.0000 .0000 .0000 -1.0000 .0299 .1495 OH 1.0035 10.0000 .0000 .0000 -1.0000 .0299 .1495 DESIGN RESULTS MEM --- SIZE LENGTH 1 ------- 8X3.5C14 -------- 29.1005 2 8X3.5C14 29.1005 E 29 RAFTER DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 2 ING COMBINATION DL+LL I* MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ------------------------------------------------------------------------------ ! # ! ! K -FT! KIP ! MOMENT SHEAR ! SHEAR BEND -L/- 1 !**! -.08! 1.13! 6.40! 3.83! .30! .01! 1 !FM! 4.20! .00! 6.40! 3.83! .00! .66! 342 1 !RS! -5.69! -1.72! 6.40! 3.8.3! .45! .89! 2 !LS! -5.69! 1.50! 6.40! 3.83! .39! .89A ------------------------------------------------------------------------------ 2 !**! -1.84! .00! 6.40! 3.83! .00! .29! MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ------------------------------------------------------------------------------ ! # ! ! K -FT! KIP ! MOMENT SHEAR ! SHEAR BEND -L/- 2 2 !**! 1.84! .00! 6.40! 3.83! .00! .29! 1597 2 !RS! -5.69! -1.50! 6.40! 3.83! .39! .89! 3 !LS! -5.69! 1.72! 6.40! 3.83! .45! .89! 3 !FM! 4.20! .00! 6.40! 3.83! .00! .66! .342 3 !**! .08! -1.13! 6.40! 3.83! .30! .01! 0 0 0 RAFTER DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 3 LO COMBINA . TION -- DL+WL _*ING -------------------------------------------------------------------------- MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ! # ! ! K -FT! ------------------------------------------------------------------------------ KIP ! MOMENT SHEAR ! SHEAR BEND -L/- 1 1 !**! -.02! .23! 8.54! 5.10! .06! .00! 1 !FM! .84! .00! 8.54! 5-.10! .00! .10! 1757 1 !RS! -1.14! -.34! 8.54! 5.10! .09! .13! 2 !LS! -1.14! .30! 8.54! 5.10! .08! .13.4 2 !**! -.37! ------------------------------------------------------------------------------ .00! 8.54! 5.10! .00! .04! MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ! # ! ! K -FT! ------------------------------------------------------------------------------ KIP ! MOMENT SHEAR ! SHEAR BEND -L/- 2 2 !**! .37! .00! 8.54! 5.10! .00! .04! 8021 2 !RS! -1.14! -.30! 8.54! 5.10! .08! .13! 3 !LS! -1.14! .34! 8.54! 5.10! .09! .13! 3 !FM! .84! .00! 8.54! 5.10! .00! .10! 1757 3 !**! .02! -.23! 8.54! 5.10! .06! .00! 0 RAFTER DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 4 3 2 I L'ib NG COMBINATION -- DL+0.5LL+WL ----------------------------- MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ------------------------------------------------------------------------------ # K -FT! KIP MOMENT SHEAR SHEAR BEND -L/- 1 -.05! .68! 8.54! 5.10! .18! .01! 1 !FM! .84! .00! 8.54! 5.10! .00! .10! 581 1 !RS! -3.41! -1.03! 8.54! 5.10! .27! .40! 2 !LS! -3.41! .90! 8.54! 5.10! .24! .40! ---------------------------- 2 !**! -1.10! .00! 8.54! L 5.10! .00! .13.1 MEM!SPN!LO!MOMENT! SHEAR! ------------------------------------------------- ALLOWABLE FORCES! UNITY RATIO DEFL # ------------------------------------------------------------------------------ ! # ! ! K -FT! KIP ! MOMENT SHEAR ! SHEAR BEND -L/- 2 2 !**! 1.10! .00! 8.54! 5.10! .00! .13! 2670 2 !RS! -3.41! -.90! 8.54! 5.10! .24! .40! 3 !LS! -3.41! 1.03! 8.54! 5.10! .27! .40! 3 !FM! .84! .00! 8.54! 5.10! .00! .10! 581 3 !**! .05! -..68! 8.54! 5.10! .18! .01! 0 0 RAFTER DESIGN LEFT ENDWALL JOB NAME: 182408 L I NG COMBINATION -- DL+LL+0.5WL 6 ------------------------------ PAGE 5 33 MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ! # ! ! K -FT! -KIP ! MOMENT SHEAR ! SHEAR BEND -L/- ------------------------------------------------------------------------------ 1 1 !**! -.08! 1.13! 8.54! 5.10! .30! .01! 1 !FM! .84! .00! 8.54! 5.10! .00! .10! 342 1 !RS! -5.69! -1.72! 8.54! 5.10! .45! .67! 2 !LS! -5.69! 1.50! 8.54! 5.10! .39! .67 ! 2 !**' -1.84! .00! 8.54! 5.10! .00! .221 ------------------------------------------------------------------------------ MEM!SPN!LO!MOMENT! SHEAR! ALLOWABLE FORCES! UNITY RATIO DEFL # ! # ! ! K -FT! KIP ! MOMENT SHEAR ! SHEAR BEND -L/- ------------------------------------------------------------------------------ 2 2 !**! 1.84! .00! 8.54! .5.10! .00! .22! 1597 2 !RS! -5.69! -1.50! 8.54! 5.10! .39! .67! 3 !LS! -5.69! 1.72! 8.54! 5.10! .45! .67! 3 !FM! .84! .00! 8.54! 5.10! .00! .10! 342 3 !**! .08! -1.13! -8.54! 5.10! .30! .01! 0 Design Thk.: 16 ga= 0.059, 15 ga= 0.065, 14 ga= 0.070, 13 ga= 0.085, 12 ga= 0.10 MIDWEST METALLIC COLUMN DESIGN LEFT ENDWALL JOB NUMBER : 182408 ( OPTIMIZATION ) wEOMETRIC DATA BAY SPACING (FEET) 3@20.000 BAY SPACING (FEET) FS EAVE HEIGHT (FEET) 25.00 FS TO RIDGE (FEET) 30.000 END FRAME (BF,MF) BF PURLIN DEPTH (INCHES) 8.00 ENDWALL BRACING TYPE C - DESIGN CRITERIA BS EAVE HEIGHT (FEET) FS ROOF SLOPE : 12 GIRT CONDITION RAFTER DEPTH (INCHES) # BAYS : 1 LOCATION :A . WIND VELOCITY PRESSURE (q): 17.39 PSF BUILDING COND. (E,P,O): E COLUMN DEFLECTION LIMIT SPCL.EW COL.PRES.COEF.: 1.000 SPCL.EW COL.SUCTION COEF SHEAR + BENDING LIMIT : 1.03 SHEAR OR BENDING LIMIT 25.00 1.00 BY -FRAME 8.000 L/ 90. -1.000 1.03 LOADING COMBINATIONS l.DL+LL 2.DL+WLP 3.DL+WLS 4.DL+0.5LL+WLP 5.DL+0.5LL+WLS 6.DL+LL+0.5WLP 7.DL+LL+0.5WLS DESIGN RESULTS AND WIND LOADING COL SECTION ANAL. TRIB. MIDSPAN PRESSURE SUCTION PRESSURE SUCTION # SIZE LENGTH SPACING HEIGHT COEF. COEF. (KLF) (KLF) --- -------- ------ ------- ------- -------- ------- -------- ------- 1 w8X15 24.392 10.000 25.417 1.000 -1.000 .174 -.174 2 W8X18 25.977 20.000 26.667 1.000 -1.000 .348 -.348 3 w8xl8 25.977 20.000 26.667 1.000 -1.000 .348 -.348 W8XI5 24.392 10.000 25.417 1.000 -1.000 .174 -.174 0 0 34 ... COLUMN DESIGN LEFT ENDWALL JOB NAME: 182408 PAGE 2 *** COLUMN NUMBER : I SIZE : W8X15 OR (FEET) = 12.250 35 I I AXIAL BENDING j< ---- COMPUTED STRESSES ----- >j< ----- ALLOWABLE STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB I MAX Lo IdAiLl � FORCE MOMENT I fa fbo fbi fbw I Fa Fbo Fbi Fbw I OUTER INNER I UNITY I DEF OC --- I ------- kips kip -ft -------- I ksi I ------ ksi ----- ksi ----- ksi I ------ I ------- ksi ksi ------ ksi ------ ksi IAXIAL ----- I ----- FLGE. ----- FLGE. I ------ CHECK I L/ V1, FM 1 1.28 .43 1 .29 .43 -.43 .001 17.16 25.99 30.00 .001 .02 .02 I -.01 1 ------- .03 I ---- 1 0 1 1 OH 1 1.28 .21 1 .29 .22 -.22 .001 5.30 12.73 30.00 .001 .05 .02 -.01 1 .07 1 2 1 FM 1 .26 -12.89 1 .06 -13.11 13.11 .001 22.88 40.00 34.65 .001 .00 -.33 .38 1 .38 1 -299 2 1 OR 1 .26 -12.89 1 .06 -13.11 13.11 .001 7.07 40.00 16.97 .001 .01 -.33 .77 1 .78 1 3 1 FM 1 .26 13.02 1 .06 13.24 -13.24 .001 22.88 34.65 40.00 .001 .00 .38 -.33 1 .38 1 299 3 1 OR 1 .26 13.02 1 .06 13.24 -13.24 .001 7.07 16.97 40.00 .001 .01 .78 -.33 1 .79 1 4 1 FM 1 .77 -12.80 1 .17 -13.02 13.02 .001 22.88 40.00 34.65 .001 .01 -.33 .38 1 .38 1 -299 4 1 OR 1 .77 -12.80 1 .17 -13.02 13.02 .001 7.07 40.00 16.97 .001 .02 -.33 .77 1 .79 1 5 1 FM 1 .77 13.19 1 .17 13.41 -13.41 .001 22.88 34.65 40.00 .001 .01 .39 -.34 1 .39 1 299 5 1 OR 1 .77 13.19 1 .17 13.41 -13.41 .001 7.07 16.97 40.00 .001 .02 .79 -.34 1 .81 1 6 1 FM 1 1.28 -12.72 1 .29 -12.93 12.93 .001 22.88 40.00 34.65 .001 .01 -.32 .37 1 .39 1 -299 6 1 OR 1 1.28 -12.72 1 .29 -12.93 12.93 .001 7,07 40.00 16.97 .001- .04 -.32 .76 1 .80 1 7 1 FM 1 1.28 13.36 1 .29 13.59 -13.59 .001 22.88 34.65 40.00 .001 .01 '.39 -.34 1 .40 1 299 7 1 OR 1 1.28 13.36 1 .29 13.59 -13.59 .001 7.07 16.97 40.00 .001 .04 .80 -.34 1 .84 1 COLUMN NUMBER 2 SIZE W8X18 - OR (FEET) 12.250 1 AXIAL BENDING j< ---- COMPUTED STRESSES ----- >j< ----- ALLOWABLE STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB I MAX LOADI I FORCE MOMENT I fa fbo fbi fbw I Fa Fbo Fbi Fbw I OUTER INNER I UNITY I DEF COMBILOC ---- I I ---- I ------- kips kip -ft -------- I ksi ------ ksi ----- ksi ----- ksi I ------ ------- ksi ksi ------ ksi ------ ksi JAXIAL' FLGE. FLGE. I CHECK I L/ I I FM 1 3.22 1,07 .61 .85 -.85 I .001 18.08 30.00 30.00 ----- I ----- .001 .03 ----- .03 ------ I -.03 1 ------- .06 I ---- 1 0 1 1 OH 1 3M .51 1 .61 .40 -.40 .001 10.46 30.00 30.00 .001 .06 .01 -.01 1 .07 1 2 1 FM 1 .64 -29.21 1 .12 -23.06 23.06 .001 24.11 40.00 40.00 .001 .01 -.58 .58 1 .58 1 -159 2 1 OR 1 .64 -29.14 1 .12 -23.01 23.01 .001 13.94 40.00 40.00 .001 .01 -.58 .58 1 .58 1 3 1 FM 1 .64 29.55 1 .12 23.33 -23.33 .001 24.11 40.00 40.00 .001 .01 .58 -.58 1 .59 ) 159 3 1 OR 1 .64 29.34 1 .12 23.17 -23.17 .001 13.94 40.00 40.00 .001 .01 .58 -.58 1 .59 1 4 1 FM 1 1.93 -28.99 1 .37 -22.89 22.89 .001 24.11 40.00 40.00 .001 .02 -.57 .57 1 .59 1 -159 4 1 OR 1 1.93 -28.94 1 .37 -22.85 22.85 .001 13.94 40.00 40.00 .001 .03 -.57 .57 1 .60 1 5 1 FM 1 1.93 29.98 1 .37 23.67 -23.67 .001 24.11 40.00 40.00 .001 .02 .59 -.59 1 .61 1 159 5 1 OR 1 1.93 29.55 1 .37 23.33 -23.33 .001 13.94 .40.00 40.00 .001 .03 .58 -.58 1 .61 1 6 1 FM 1 3.22 -28.77 1 .61 -22.71 22.71 .001 24.11 40.00 40.00 .001 .03 -.57 .57 1 .59 1 -159 6 1 OR 1 3.22 -28.74 1 .61 -22.69 22.69 .001 13.94 40.00 40.00 .001 .04 -.57 .57 1 .61 1 7 1 FM 1 3.22 30.41 1 .61 24.01 -24.01 .001 24.11 40.00 40.00 .001 .03 .60 -.60 1 .63 1 159 7 1 OR 1 3.22 29.75 1 .61 23.49 -23.49 .001 13.94 40.00 40.00 .001 .04 .59 -.59 1 .63 1 COLUMN NUMBER 3 SIZE W8XI8 .** OR (FEET) = 12.250 I AXIAL BENDING j< ---- COMPUTED STRESSES ----- >j< ----- ALLOWABLE STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB I MAX LOADI I FORCE MOMENT I fa fbo fbi fbw I Fa Fbo Fbi Fbw I OUTER INNER I UNITY I DEF COMBILOC ---- I ---- ------- kips kip -ft -------- I ksi ------ ksi ----- ksi ----- ksi I ksi ------- ksi ksi ksi JAXIAL FLGE. FLGE. I CHECK I L/ I I I I FM 1 3.22 1.07 I 1 .61 .85 -.85 ------ I ------- .001 18.08 30.00 ------ 30.00 ----- I ----- .001 .03 ----- .03 ------ I -.03 1 ------- .06 I ---- 1 0 1 1 OR 1 3.22 .51 1 .61 .40 -.40 .001 10.46 30.00 30.00 .001 .06 .01 -.01 1 .07 1 2 1 FM 1 .64 -29.21 1 .12 -23.06 23.06 .001 24.11 40.00 40.00 .001 .01 -.58 .58 1 .58 1 -159 2 1 OR 1 .64 -29.14 1 .12 -23.01 23.01 .001 13.94 40.00 40.00 .001 .01 -.58 .58 1 58 1 3 1 FM 1 .64 29.55 1 .12 23.33 -23.33 .001 24.11 40.00 40.00 .001 .01 .58 -.58 1 .59 1 159 3 1 OR 1 .64 29.34 1 .12 23.17 -23.17 .001 13.94 40.00 40.00 .001 .01 .58 -.58 1 .59 1 4 1 FM 1 1.93 -28.99 1 .37 -22.89 22.89 .001 24.11 40.00 40.00 .001 .02 -.57 .57 1 -59 1 -159 4 1 OH 1 1.93 -28.94 1 .37 -22.85 22.85 .001 13.94 40.00 40.00 .001 .03 -.57 .5.7 1 .60 1 5 1 FM 1 1.93 29.98 1 .37 23.67 -23.67 .001 24.11 40.00 40.00 .001 .02 .59 -.59 1 .61 1 159 5 1 OR 1 1.93 29.55 1 .37 23.33 -23.33 .001 13.94 40.00 40.00 .001 .03 .58 -.58 1 .61 1 6 1 FM 1 3.22 -28.77 1 .61 -22.71 22.71 .001 24.11 40.00 40.00 .001 .03 -.57 .57 1 .59 1 -159 6 1 OH 1 3.22 -28.74 1 .61 -22.69 22.69 .001 13.94 40.00 40.00 .001 .04 -.57 .57 1 .61 1 7 1 FM 1 3.22 30.41 1 .61 24.01 -24.01 .001 24.11 40.00 40.00 .001 .03 .60 -.60 1 .63 1 159 7 1 OR 1 3.22 29.75 1 .61 23.49 -23.49 .001 13.94 40.00 40.00 .001 .04 .59 -.59 1 .63 1 0 JOB NAME: 182408 - COLUMN NUMBER - COLUMN DESIGN - LEFT ENDWALL PAGE 3 4 SIZE : W8XI5 OH (FEET) = 12.250 BENDING.j< ---- COMPUTED I AXIAL L I fa FORCE fbi LOC ---- � k I ------- ilps28 Fbo FM I ksi 1 OH 1.28 2 FM .26 2 OH .26 3 FM .26 3 OH 1 .26 4 FM .77 4 OH .77 5 FM .77 5 OH 77 6 FM 1.28 6 OH 1.28 7 FM 1.28 7 OH 1.28 - COLUMN DESIGN - LEFT ENDWALL PAGE 3 4 SIZE : W8XI5 OH (FEET) = 12.250 BENDING.j< ---- COMPUTED STRESSES ----- >j< ----- ALLOWABLE MOMENT I fa fbo fbi fbw I Fa Fbo kip -ft -------- I ksi ksi ----- ksi ksi I ksi ksi .43 I ------ 1 .29 .43 ----- -.43 ------ I ------- .001 17.16 ------ 25.99 .21 1 .29 . .22 -.22 .001 5.30 12.73 -12.89 .06 -13.11 13.11 .001 22.88 40.00 -12.89 .06 -13.11 13.11 .001 7.07 40.00 13.02 1 .06 13.24 -13.24 .001 22.88 34.65 13.02 1 .06 13.24 -13.24 .001 7.07 16.97 -12.80 1 .17 -13.02 13.02 .001 22.88 40.00 -12.80 1 .17 -13.02 13.02 .001 7.07 40.00 13.19 1 .17 13.41 -13.41 .001 22.88 34.65 13.19 1 .17 13.41 -13.41 .001 7.07 16.97 -12.72 1 .29 -12.93 12.93 .001 22.88 40.00 -12.72 1 .29 -12.93 12.93 .001 7.07 40.00 13.36 1 .29 13.59 -13.59 .001 22.88 34.65 13.36 1 .29 13.59 -13.59 .001 7.07 16.97 STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB Fbi Fbw I OUTER INNER I UNITY ksi ------ ksi JAXIAL ----- ----- FLGE. FLGE. I CHECK 30.00 I .001 .02 ----- .02 ------ -.01 ------ .03 30.00 .001 .05 .02 -.01 1 .07 34.65 .001 .00 -.33 .38 1 .38 16.97 .001 .01 -.33 .77 1 .78 40.00 .001 .00 .38 -.33 1 .38 40.00 .001 .01 .78 -.33 1 .79 34.65 .001 .01 -.33 .38 1 .38 16.97 .001 .02 -.33 .77 1 .79 40.00 .001 .01 .39 -.34 1 .39 40.00 .001 .02 .79 -.34 1 .81 34.65 .001 .01 -.32 .37 1 .39 16.97 .001- .04 -.32 .76 1 .80 40.00 .001 .01 '.39 -.34 1 .40 40.00 .001 .04 .80 -.34 1 .84 3f; 1 MAX I DEF I L/ 0 -299 1 299 1 -299 1 299 1 -299 1 299 1 Design Thk. : 16 ga= 0 .059, 15 ga= 0. 065, 14 ga= 0. 070, 13 ga= 0. 085, 12 ga= 0 . 10 MIDWEST METALLIC COLUMN DESIGN RIGHT ENDWALL JOB NUMBER : 182408 OPTIMIZATION aGEOMETRIC DATA *** BAY SPACING (FEET) 3@20.000 BAY SPACING (FEET) FS EAVE HEIGHT (FEET) 25.00 FS TO RIDGE (FEET) 30.000 END FRAME (BF,MF) MF PURLIN DEPTH (INCHES) 8.00 ENDWALL BRACING TYPE D DESIGN CRITERIA BS EAVE HEIGHT (FEET) FS ROOF SLOPE : 12 GIRT CONDITION RAFTER DEPTH (INCHES) # BAYS : 0 LOCATION 25.00 1.00 BY -FRAME .000 WIND VELOCITY PRESSURE (q): 17.39 PSF BUILDING COND. (E,P,O): E COLUMN DEFLECTION LIMIT L/ 90. SPCL.EW COL.PRES.COEF.: 1.000 SPCL.EW COL.SUCTION COEF. -1.000 SHEAR + BENDING'LIMIT : 1.03 SHEAR OR BENDING LIMIT 1.03 LOADING COMBINATIONS l.DL+LL 2.DL+WLP 3.DL+WLS 4.DL+0.5LL+WLP 5.DL+0.5LL+WLS 6.DL+LL+0.5WLP 7.DL+LL+0.5WLS DESIGN RESULTS AND WIND LOADING COL SECTION ANAL. TRIB. MIDSPAN PRESSURE SUCTION PRESSURE SUCTION # SIZE LENGTH SPACING HEIGHT COEF. COEF. (KLF) (KLF) --- -------- ------ ------- ------- -------- ------- -------- ------- MAIN FRAME COLUMN 2 W8X15 25.977 20.000 26.667 1.000 -1.-000 .348 -.348 3 W8Xl5 25.977 20.000 26.667 1.000 -1.000 .348 -.348 0 MAIN FRAME COLUMN 3 JOB NAME: 182408 COLUMN NUMBER COLUMN NUMBER ... COLUMN DESIGN - RIGHT ENDWALL 1 MAIN FRAME COLUMN 2 SIZE : W8X15 OH (FEET) = 12.172 PAGE 2 I I AXIAL BENDING l< ---- COMPUTED STRESSES ----- >j< ----- ALLOWABLE I FORCE COMBILOC ---- ---- FORCE MOMENT fa, fbo fbi fbw I Fa Fbo FM OC kips kip -ft � ks ksi ksi ksi I ksi ksi 1 1 FM ------- .00 -------- .00 ------ .00 ----- .00 ----- .00 ------ I ------- .001 ------ 15.90 30.00 1 1 OH .00 .00 1 .00 .00 .00 .001 5.37 30.00 2 1 FM .00 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 2 1 OH 1 .00 -29.22 1 .00 -29.72 29.72 .001 7.16 40.00 3 1 Fm 1 .00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 3 1 OH 1 .00 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 4 1 FM 1 .00 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 4 1 OH 1 .00 -29.22 1 .00 -29.72 29.72 .001 7.16 40.00 5 1 FM 1 .00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 5 1 OH 1 .00 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 6 1 FM 1 .00 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 6 1 OH 1 .00 -29.22 1 .00 -29.72 29.72 .001 7.16 40.00 7 1 FM 1 .00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 7 1 OH 1 .00 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 - COLUMN NUMBER 3 SIZE W8X15 .** OH (FEET) 12.172 1 I l< ---- COMPUTED I AXIAL LOADI I fa I FORCE COMBILOC ---- ---- I kips ------- I 1 1 FM I 1 .00 1 1 OH 1 .00 2 1 FM 1 .00 2 1 OH 1 .00 3 1 FM 1 .00 3 1 OH 1 .00 4 1 FM 1 .00 4 1 OH 1 .00 5 1 FM 1 .00 5 1 OH 1 .00 6 1 FM 1 .00 6 1 OH 1 .00 7 1 FM 1 .00 7 1 OH 1 .00 & OLUMN NUMBER 0 BENDING l< ---- COMPUTED STRESSES ----- >1< ----- ALLOWABLE MOMENT I fa fbo fbi fbw I Fa Fbo kip -ft I ksi ksi ksi ksi I ksi ksi -------- .00 I ------ 1 .00 7 ---- .00 ----- .00 ------ I ------- .001 15.90 ------ 30.00 .00 1 .00 .00 .00 .001 5.37 30.00 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 -29.22 1 .00 -29.72 29.72 .001 7.16 40.00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 -29.22 1 .00 -29.72 29.72 .001. 7.16 40.00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 -29.34 1 .00 -29.83 29.83 .001 21.20 40.00 -29.22 1 .00 -29.72 29.72 .001 7.16 40.00 29.34 1 .00 29.83 -29.83 .001 21.20 34.65 29.22 1 .00 29.72 -29.72 .001 7.16 29.89 4 MAIN FRAME COLUMN 318 STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB I MAX Fbi Fbw I OUTER INNER I UNITY I DEF ksi ------ ksi JAXIAL ----- I ----- FLGE. ----- FLGE. I ------ CHECK I L/ 25.99 .001 .00 .00 I .00 1 ------- .00 I ---- 1 0 22.42 .001 .00 .00 .00 1 .00 1 34.65 .001 .00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -.74 .99 1 .99 1 40.00 .001 .00 .86 -.75 1 .86 1 123 40.00 .001 .00 .99 -.74 1 .99 1 34.65 .001 .00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -.74 .99 1 .99 1 40.00 .001 .00 .86 -.75 1 .86 1 123 40.00 .001 .00 .99 -.74 1 .99 1 34.65 .0ot- -.00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -'.74 .99 1 .99 1 40.00 .001 .00 .86 -.75 1 .86 1 123 46.00 .001 .00 .99 -.74 1 .99 1 STRESSES ----- >j< --- UNITY CHECK ---- >1 COMB I MAX Fbi Fbw I OUTER INNER I UNITY I DEF ksi ------ ksi JAXIAL ----- ----- FLGE. ----- FLGE. I CHECK I L/ 25.99 I .001 .00 .00 ------ I .00 1 ------- .00 I ---- 1 0 22.42 .001 .00 .00 .00 1 .00 1 34.65 .001 .00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -.74 .99 1 .99 1 40.00 .001 .00 .86 -.75 1 .86 1 123 40.00 .001 .00 .99 -.74 1 .99 1 34.65 .001 .00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -.74 .99 1 .99 1 40.00 .001 '.00 .86 -:75 1 .86 1 123 40.00 .001 .00 .99 -.74 1 .99 1 34.65 .001 .00 -.75 .86 1 .86 1 -123 29.89 .001 .00 -.74 .99 1 .99 1 40.00 .001 .00 .86 -.75 1 .86 1 123 40.00 .001 .00 .99 -.74 1 .99 1 MIDWEST METALLIC PAGE I BRACING DESIGN JOB NUMBER : 182408 (FULL OPTIMIZATION) **,O*EOMETRIC DATA B� CING (FEET) 3@20.00,25.00 B LA RA TIER SPACES (FT) 3@20.00 FRONT EAVE HEIGHT (FEET): 25.0000 BACK EAVE HEIGHT (FEET) 25.0000 FRONT SIDE ROOF SLOPE 1.0000/12 FRONT SIDE TO RIDGE 30.0000 BRACING DATA RF BRACING TYPE CABLE # BAYS 1 LOCATION 2 FS BRACING TYPE CABLE # BAYS 1 LOCATION I BS BRACING TYPE CABLE # BAYS 1 LOCATION I LE BRACING TYPE CABLE # BAYS 1 LOCATION A RE BRACING TYPE DIAPHRAGM # BAYS 1 LOCATION DESIGN CRITERIA WIND VELOCITY PRESS (q) : 17.3860 PSF EDGE STRIP WIDTH (FEET) 20.000 INTERIOR COEFFICIENT,GCpR: 1.3000 EDGE STRIP COEFFICIENT,GCpX 1.3000 MAXIMUM UNITY CHECK RATIO: 1.0345 MAX. HORIZONTAL DEFLECTION .0000 LOADING COMBINATIONS 1. WIND LOAD 0 ... BRACING DESIGN JOB NUMBER : 182408 .** ROOF BRACING PAGE 2 (FRONT TO BACK SIDE) *** BRACING RESULTS *** ------------------------------------------------------------------------------- IT TIER I C. B R A C I N G - S I Z E T E N S 1 0 N SPACING BAY #2 BAY #0 BAY #0 BAY #0 BAY #0 1 1 1 20.0000 1 3/8" DIA I HFS) 1 1 8.52 .1 ------------------------------------------------------------------------------- 1 2 1 20.0000 1 1/4" DIA I I I 1 .00 1 ------------------------------------------------------------------------------- 1 3 1 20.0000 1 3/8" DIA I l(BS) 1 1 8.52 1 ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- I COL I P I S T R U T S T Y P E F 0 R C E I # I FORCE I BAY #2 1 BAY #0 BAY #0 BAY #0 1 BAY #0 ------------------------------------------------------------------------------- I FS 1 2.8723 1 STRUT ZEE I lEAVE 1 1 8.90 1 ------------------------------------------------------------------------------- 1 2 1 6.0271 1 CL - 4 1 1 1 1 6.03 1 ------------------------------------------------------------------------------- 1 3 1 6.0271 1 CL - 4 1 1 1 1 6.03 1 ------------------------------------------------------------------------------- I BS 1 2.8723 1 STRUT ZEE I lEAVE 1 1 8.90 1 ------------------------------------------------------------------------------- E 0 w JOB NO. 41 *M -E QUOTE NO. DESCRIPTION DESIGNEDBYA!V CHK'DBY- - DATE SHEET NO. - ------ -------- ... .......... (4.e V6 vt/ r,> V� -t. "3 -9 7 vs ------ ----- - --------- ... BRACING DESIGN JOB NUMBER : 182408 *** WALL BRACING PAGE 3 *** FRONTSIDE *** ------------------------------------------------------------------------------- TIER I C. B R A C I N G - S I Z E / T E N S 1 0 N �w BAY #0 BAY #0 1 BAY #0 SPACING BAY #1 BAY #0 11.7083 1 3/8" DIA I 1UPPER1 1 10.04 1 ------------------------------------------------------------------------------- I FS 1 13.2917 1 1/2" DIA I ILOWERI 1 10.80 1 -------------------------------------------------------------------- L ---------- I STRUT TYPE I CL - 1 1 ------------------------------------------------------------------------------- *** BACKSIDE *** ------------------------------------------------------------------------------- I I TIER I 1C. B R A C I N G - S I Z E / T E N S 1 0 N I IWALL I SPACING I BAY #1 1 BAY #0 1 BAY #0 1 BAY #0 1 BAY #0 1 ----------------------------------------------- 7 ------------------------------- 1 1 11.7083 1 3/8" DIA I 1UPPER1 1 10.04 1 ------------------------------------------------------------------------------- I BS 1 13.2917 1 1/2" DIA I ILOWERI 1 10.80 1 ------------------------------------- 7 ----------------------------------------- I STRUT TYPE I CL - 4 1 ------------------------------------------------------------------------------- *** LEFT ENDWALL *** ------------------------------------------------------------------------------- I I TIER I Ic, B R A C I N G - S I Z E / T E N S 1 0 N I IWALL I SPACING I BAY #1 1 BAY #0 1 BAY #0 1 BAY #0 1 BAY #0 1 ------------------------------------------------------------------------------- 1 1 10.4849 1 1/4" DIA I 1UPPER1 1 3.23 1 ------------------------------------------------------------------------------- I LE 1 13.2917 1 1/4" DIA I ILOWERI 1 3.45 1 ------------------------------------------------------------------------------- I STRUT TYPE I CL - 4 1 ------------------------------------------------------------------------------- *_* HT ENDWALL *** - - --------------------------------- RIGHT ENDWALL IS MAINFRAME NO DIAPHRAM ACTION CALCULATED 42 AITO/ST111 DESIGN A SYNERCOM TECHNOLOGY, INC. DEVELOPMENT RELEASE 6 MOD 12e FEBRUARY 1999 Job Start Date 10- 7-99 Time 10:15:49 TITLE - JOB#182408A/EGD - 2-4 BY - EGD IDENTIFICATION DATE - 10/06/99 UNITS OPTIONS INPUT .... ENGLISH OUTPUT .... ENGLISH TYPE - RIGID FRAME REPORT OPTIONS .... ANCHOR BOLTS AND CONNECTIONS .... FLANGE BRACE REPORT .... DESIGN SUMMARY REPORT WITH DEFLECTIONS FREE FORMAT .... SHORT OUTPUT EXECUTION OPTIONS EXECUTION MODE ANALYSIS ONLY MAXIMUM NUMBER OF ITERATIONS 1 UNITY CHECK RANGE = 0.950 TO 1.050 MAXIMUM SEGMENT SIZE = 2.000 FT COEF, OF LINEAR EXPANSION O.00OOO65OOO/DEG.F MOD. OF ELASTICITY,E = 29000000. PSI LOCATE FLANGE BRACING NO 0 4.3 D E S I G N I N P U T E C H 0 NCI lding Systems, L.P. JO A& 2-4 w MEMBERS LOADED SPLICES LOADED JON182408A/EGD - 2-4 EGD,10/06/99 ..... AC,FB,,DF .... SH 3,1 ...... SPANS 60., 25-8-10.375 ... 30.375--G 13.292-19.292, 6Aj,,W8j,j6A,j,55.,j,jjj,,jj,46, 30.375,18.375 ... 18.375,l.j8.j3O.j,2OOO5jP,S 6A ... W8,ofik,,55-46. 6AjjjWljjj6Ajj,20.,55.446. 5.j5.,l.j,,X,,X LOAD FACTORS,22.5,85. DEAD LOAD -045 LIVE LOAD -270 WIND LOAD.17.386,PSF,SPEC,,8,-.7,-.7,-.5 LOAD CONDITIONS 1,2A5 LOADCOND LDCN.5,100.,DL,100.,WL2,,,,,DL + EQ LoW,WL2,GLOB,X,CONC,,1.000 N EN 0 PAGE 1 10- 7-99 44 M A C R 0 1 N P U T E C H 0 4 5 NCi6ding Systems, L.P. CYCLE I JO 08A/EGD - 2-4 10- 7-99 SPAN LENGTHS 60.000 0.000 0.000 0.000 0.000 0.000 0.000 01000 0 LEFT EXTERIOR COLUMN EAVE WALL GIRT BASE MID MID KNEE BASE TEMP BASE F G HEIGHT SLOPE SIZE DEPTH DEPTH DIST. DEPTH SETTLE DIFF DISPL X R Kx 25.000 0.000 8,000 10.375 0.000 0.000 30.375 0.00 0.00 0.00 G 0.00 GIRT AND BRACE LOCATIONS 13.292 19.292 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 6A W8 6A 55.00 0.00 46.00 RAFTER AT LEFT KNEE 30.375 18.375 0.000 0.000 18.375 1.000 8.000 30.000 0.0 20005 P S 0 SECTION 1 FOR RAFTER SECT FLANGE WEB /OUTER FLANGE-/ ------ WEB ----- /-INNER FLANGE-/ LENGTH FY FY Kx 6A W8 6A 0.00 55.00 46.00 0.00 0 SECTION 2 FOR RAFTER SECT FLANGE WEB /OUTER FLANGEV ------ WEB ----- /-INNER FLANGEV LENGTH FY FY Kx 6A wi 6A 20.00 55.00 46.00 0.00 0 PU*AND BRACE LOCATIONS 5.000 5.000 1.000 X X 0 SYMMETRIC FRAME GENERATED WITH CENTERLINE AT X = 28.90 FT 03 + ia s ii + iitwi + ia Ilm + llZ/T + IG 11M + 19 z ([Vol 3AII + GV3(I T SNO11MOS39 NOIlIGN03 GVOI .0 10 'OOT ZIM IOOT la s .0 '001 11 'OS lim 'OOT la .0 TOT lim 'OS 11 'OOT la .0 .0 'OOT IIM IOOT la z .0 TOT 11 'OOT la I AVMV NOIII(IN03 UVOI (IN3 XIIM ZTTIZ'O OSBT'�Z ZTRZ'O 00000'0 JINn X qO19 IIM S 1#1 IMIG TT6TO*O- 00000'0 TT6TO'O- 00000'0 AINn A qOI9 19 4 S AllM M6Z'O 608ZT'SZ MOO 00000'0 JINA A q019 IIM 4 ol X -11M 6WO'O 608ZT'8Z 6Z4ZO'O 00000'0 JINA X q019 IIM Vol IMIG �SZTO'O- 00000'0 �-SM'0- 00000'0 JINn A q019 IG avol Ma T6ZW'O- 00000'0 T6ZW'O- 00000'0 AINn A qoig ia Gol 3AII 9t7ZgZ'O- 00000'0 9tZ8Z'O- 00000'0 JINn A qO19 11 4 Vol AllM MET 608ZI*SZ MET 00000'0 JINn A qoig lim z Vol XIIM 6WO'0- 608ZT'SZ 6WO'0- 00000'0 JINn x qoig lim z Vol IMIG iSZTO'O- 00000'0 �SZTO'O- 00000'0 JINn A qoig la z Vol GV39 T6ZW'O- 00000'0 T6ZW'O- 00000'0 JINn A qoig ia z Vol IAII 94Z?Z'O- 00000'0 9UZ'O- 00000'0 AINn A 9019 11 1 Z avol X11M 6LZa'O OSTN'�Z 6lla'O 00000'0 JINn X qO19 IIM Z T avol IMla TT6TO'O- 00000'0 TT6TO'O- 00000'0 JINn A qO19 la Z T avol 000,0 00010 000'T 000,0 3NO3 X q019 ZIM Z Vol 0 slavol 03 + IG 00,0 00'0 ZIM 00'OOT la 00'OOTS NJ(n GNOYIVOI 0 0010 0010 0010 00'0. 0 0 0 0 0 0 0 0 0 0 0 S � Z T 0 SNOIIIGN03 ([Vol OOS*O-OOZ'O-OOZ'0-008'0 33dS JSd 9K'ZT Vol GNIM 000*0 00010 00010 000,0 OZZ'O GVOI 3AII 000*0 000,0 000,0 000,0 sw10 Vol av3a 000'ss OOS'ZZ SbODVA Vol 66-Z -OT �-z - (193ABOA r VI 'SU21SAS 6UTP1103N 0 H 3 3 1 A d N 1 0 � 3 V W F R A M E D E S I G N D A T A NCI lding Systems, L.P, JO �& --A/EGD - 2-4 10- 7-99 mr CONFIGURATION (SYMMETRIC FRAME) ... BUILDING WIDTH = 60.00 FT NUMBER OF SPANS = I SPAN WIDTHS (FT) = 60.00 DESIGN BAY SIZE = 22.50 FT LEFT EAVE HEIGHT = 25.00 FT RIGHT EAVE HEIGHT = 25.00 FT LEFT COLUMN SLOPE 0.00 /12 LEFT RAFTER SLOPE 1.00 /12 RIGHT RAFTER SLOPE 1.00 /12 RIGHT COLUMN SLOPE 0.00 /12 GIRT DEPTH 8.00 IN PURLIN DEPTH 8.00 IN LOADINGS ... DEAD LOAD = 2.000 PSF LIVE LOAD = 12.000 PSF WIND LOAD = 17.386 PSF WIND LOAD PARAMETERS ... WIND LOAD METHOD = SPEC WI ENSITY = 17.39 PSF 0 M OF HEIGHT = 25.00 FT WIND LEFT COEFFICIENTS = 0.80 -0.70 -0.70 -0.50 FOR WLL WIND RIGHT COEFFICIENTS = 0.80 -0.70 -0.70 -0.50 FOR WLR LOAD CONDITIONS ... LOAD CONDITION 1 = DEAD + LIVE LOAD LOAD CONDITION 2 = DL + WLL LOAD CONDITION 3 = DL + 1/2LL + WLL LOAD CONDITION 4 = DL + 1/2WLL + LL LOAD CONDITION 5 = DL + EQ E 47 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. MEMBER VERTICAL HORIZONTAL PAGE NO. - 1 JOB#182408A/EGD - 2-4 HORIZONTAL JOINT JOINT DATE 10- 7-99 ------------------------------------------------------------------------------------------------------------------------ REACTION DEFLECTION DEFLECTION 48 NUMBER (KIPS) (KIPS) (KIP -Fr) (IN) F[SEACTIONS AND DEFLECTIONS - LOAD CONDITION 1 - DEAD + LIVE LOAD SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION -DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ ------ -------- 1 1 10.387 -------- 4.057 -------- 0.000 -------- 01000 -------- 01000 2 2 -0.010 -0.226 3 5 -0.700 -0.122 3 1.242 4.218 -2.259 0.000 5 -0.700 0.122 6 4 5 -3.383 -0.010 0.226 7 5 10.387 -4.057 0.000 0.000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 2 - DL + WLL SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -Fr) (IN) (IN) ------ 1 ------ 1 -------- -8,474 -------- -9.683 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0.149 4.363 3 -0.271 4,384 4 3 1.533 4.238 5 1.242 4.218 0 4 0.159 4.051 7 5 -3.383 -3.030 0.000 01000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 3 - DL + 1/2LL + WLL SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ 1 ------ 1 -------- -4.424 -------- -8,034 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0,153 4.271 3 -0.5% 4.334 4 3 0.613 4,238 5 0.957 4.268 6 4 0.1% 4.144 7 5 0,667 -4.680 0.000 0.000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 4 - DL + 1/2WLL + LL SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -Fr) (IN) (IN) ------ 1 ------ 1 -------- 5.007 -------- -1.164 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0.083 1.976 -0.770 2.081 3 -1.283 2.119 5 -0.014 2.220 6 4 0,071 2.231 7 -------------------------------------------------------------------------------- 5 7.552 -5.193 0.000 0.000 01000 49 0 0 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 2 JOB#182408A/EGD - 2-4 DATE 10- 7-99 ------------------------------------------------------------------------------------------------------------------------ F R*A CTIONS AND DEFLECTIONS.- LOAD CONDITION 5 - DL + EQ SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ ------ -------- -------- -------- -------- -------- 1 1 1.886 0.225 0.000 0.000 0,000 2 2 -0.024 0.546 3 -0.241 0.579 4 3 -0.397 0.589 5 -0.007 0.620 6 4 0.019 0.623 7 5 2.687 -1.225 0.000 01000 0.000 ------------------------------------------------------------------------------------------------------------------------ 0 0- 00 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 3 JOB#182408A/EGD - 2-4 DATE 10- 7-99 EXT MN 1- 2 LENGTH 23.16 FT MEMBER ANGLE 87.84 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 443. LB S L ECOT ENGTH YIELD NO, SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 22.07 55, 46. 12 1.84 FT 10.38 IN 30.38 IN 6.000 XO.1875 0.1644 6.000 XO.1875 1.011 12.0 FT 2 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES- --MAXIMUM STRESSES- --UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D SECTION FORCE MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING --COND (KIPS) (KIPS) T 1 -8.91 87.68 36.80 29.64 44.00 -1.57 29.% -29.96 0.04 1.01 0.68 1 -3.68 12.32 ------------------------------------------------------------------------------------------------------------------------ RAFTER 2- 3 LENGTH 28.18 FT MEMBER ANGLE 5.94 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 494. LB SECTION LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 7.05 55. 46. 4 1.76 FT 30.38 IN 18.38 IN 6.000 XO.1875 0,1644 6.000 XO.1875 0,865 1.1 FT 2 2 20.00 55. 46. 11 1.82 FT 18.38 IN 18.38 IN 6.000 XO.1875 0.1345 6.000 XO.1875 0.868 8.2 FT 2 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES- -MAXIMUM STRESSES --- -- UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D SECTION FORCE MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - NO. (KIPS) (KIP -Fr) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING COND (KIPS) (KIPS) T 1 -3.19 1-16.45 36.80 27.79 44.00 -0.44 24.05 -24.05 0.01 0.87 0.55 1 8.81 12.32. 2 -2.64 63.67 36.80 32.17 44.00 -0.56 27.92 -27.92 0.02 0.87 0.63 1 6.71 11.24 * ER 4- 3 LENGTH 28.18 FT MEMBER ANGLE 174.06 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 494. LB SECTION LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 7.05 55. 46, 4 1.76 FT 30.38 IN 18.38 IN 6.000 XO.1875 0.1644 6.000 XO.1875 0.786 1.1 FT 1 2 20.00 55. 46. 11 1.82 FT 18,38 IN 18.38 IN 6.000 XO.1875 0.1345 6.000 XO.1875 0.835 25.5 FT 1 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES- --MAXIMUM STRESSES --- -- UNITY CHECK COMPONENTS— SECTION FORCE. MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. NO, (KIPS) (KIP -FT) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING 1 5.47 -74.81 16.95 33.00 20.85 0.76 -15.45 15.45 0.04 0.47 0.74 2 4.12 42.11 12.61 24.13 33.00 0.88 18.46 -18.46 0.07 0.77 0.56 ------------------------------------------------------------------------------------------------- 0 ---- WEB SHEAR ------ D LOAD FORCE ALLOW. - COND (KIPS) (KIPS) T 1 8.81 12.32 1 6.71 11.24 51 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 4 JOB#182408A/EGD - 2-4 DATE 10- 7-99 ------------------------------------------------------------------------------------------------------------------------ 52 E'T UMN 5- 4 LENGTH 23.16 FT MEMBER ANGLE 92.16 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 443. LB SEOC LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 22.07 55. 46. 12 1.84 FT 10.38 IN 30.38 IN 6.000 XO.1875 0.1644 6.000 XO.1875 0.895 22.1 FT I (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES- --MAXIMUM STRESSES- --UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D SECTION FORCE MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING -- COND (KIPS) (KIPS) T 1 10.11 -81.01 15.17 33.00 20.85 1.41 -16.73 16.73 0.09 0.51 0.80 1 -3.'68 12.32 ------------------------------------------------------------------------------------------------------------------------ TOTAL FRAME WEIGHT IS 1873. LB F L A N G E B R A C E R E P 0 R T NCI Building Systems, L.P. JOBfO8A/EGD - 2-4 E FLANGE BRACING = N ---------------------------- COLUMN 1 - 2 GIRTS LOCATED AT 13.29FT 19.29FT BRACED AT x x RAFTER 2 - 3 PURLINS LOCATED AT 3.04FT 8,05FT 13.07FT 18.09FT 23.11FT 27.17FT 28.18FT BRACED AT x x x x x PAGE NO. - 1 DATE 10- 7-99 RAFTER 4 - 3 PURLINS LOCATED AT 3.04FT 8.05FT 13,07FT 18.09FT 23.11FT 27.17FT 28.18FT BRACED AT x x x x x COLUMN 5 - 4 GIRTS LOCATED AT 13.29FT 19.29FT BRACED AT x x ---------------------------------------------------------------------------------------------------------------------- 0 0 53 AUTO/STEEL DESIGN A SYIERCII TECHNOLOGY, INC, I)EVILO1111T RELEASE 6 MOD 12e FEBRUARY 1999 Job Start Date 10- 7-99 Time 10:17:49 TITLE - JOB#1824085/EGD - 5 BY - EGD IDENTIFICATION DATE - 10/06/99 UNITS OPTIONS INPUT .... ENGLISH -OUTPUT .... ENGLISH TYPE - RIGID FRAME REPORT OPTIONS .... ANCHOR BOLTS AND CONNECTIONS .... FLANGE BRACE REPORT .... DESIGN SUMMARY REPORT WITH DEFLECTIONS .... FREE FORMAT .... SHORT OUTPUT EXECUTION OPTIONS EXECUTION MODE ANALYSIS ONLY MAXIMUM NUMBER OF ITERATIONS 1 UNITY CHECK RANGE = 0.950 TO 1.050 MAXIMUM SEGMENT SIZE = 2.000 FT COEF. OF LINEAR EXPANSION O,OOOOO65OOO/DEG.F MOD. OF ELASTICITY,E = 29000000. PSI LOCATE FLANGE BRACING NO 0 54 D E S I G N I N P U T E C H 0 NCI,J&Idlng Systems, L.P, PAGE 1 JOIVO85/EGD - 5 10- 7-99 MEMBERS LOADED SPLICES LOADED JOB#1824085/EGD - 5 EGD,10/06/99 ..... AC,FB,,DF .... SH 3,1 .... �—N SPANS 60., 25.jj8.jlO.5,j,3O.5jjjjjG 0.0 8B,jjW8jjj8B,,j55.��,j,,jjjjj46. 30.375jl8.375 ... 18.375,l.j8.,3O.jj2OOO5jPjS 6A,jjW8-6A .... 55.,46. 6A—Wlj�,6A�-20-55-46. 5.,5.,l.,,,XjjX LOAD FACTORS,12.5,85. DEAD LOAD -025 LIVE LOAD -150 WIND LOAD,17.386,PSF,SPEC,.8,-1.2,-1.2,-.5 LOAD CONDITIONS 1,2,45 LOADCOND LDCN,5,1OO.,DL,IOO.,WL2�,,,,DL + EQ LOAD L WL2,GLOB,X,CONC,,0.500 EN* 0 55 M A C R 0 1 N P U T E C H 0 56 NCI 11 CYCLE 1 JO#ding Systems, L.P. 085/EGD - 5 10- 7-99 SPAN LENGTHS 60,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0 LEFT EXTERIOR COLUMN EAVE WALL GIRT BASE MID MID KNEE BASE TEMP BASE F G HEIGHT SLOPE SIZE DEPTH DEPTH DIST. DEPTH SETTLE DIFF DISPL X R Kx 25.000 0.000 8.000 10.500 0.000 0.000 30,500 0.00 0.00 0.00 G 0.00 GIRT AND BRACE LOCATIONS 0.000 0.000 0.000 01000 0.000 0.000 0.000 0.000 0,000 0.000 8B W8 8B 55.00 0.00 46.00 RAFTER AT LEFT KNEE 30.375 18.375 0.000 0.000 18.375 1.000 8.000 30.000 0.0 20005 P S 0 SECTION 1 FOR RAFTER SECT FLANGE WEB /OUTER FLANGEV ------ WEB ----- /-INNER FLANGE-/ LENGTH FY FY Kx 6A W8 6A 0.00 55.00 46.00 0.00 0 SECTION 2 FOR RAFTER SECT FLANGE WEB /OUTER FLANGE-/ ------ WEB ----- /-INNER FLANGEV LENGTH FY FY Kx 6A Wl 6A 20.00 55.00 46.00 0.00 0 AAND BRACE LOCATIONS 5.000 5.000 1.000 X X 0 SYMMETRIC FRAME GENERATED WITH CENTERLINE AT X = 28.90 FT M A C R 0 1 N P U T E C H 0 NCI, lding Systems, L,P. J& JOI W 5/EGD - 5 LOAD FACTORS 12.500 85.000 DEAD LOAD 0.025 0.000 0.000 0.000 0,000 LIVE LOAD 0.150 0.000 0.000 0.000 0.000 WIND LOAD 17.386 PSF SPEC 0.800-1.200-1.200-0.500 10- 7-99 LOAD CONDITIONS 12 4 5 0 0 0 0 0 0 0 0 0 0 0 0.00 0.00 0.00 Oloo LOADCOND LDCN 5100.00 DL 100.00 WL2 0.00 Oloo DL + EQ LOADS LOAD 2 3 WL2 GLOB X CONC 0.000 0.500 01000 0.000 LOAD 1 2 DL GLOB Y UNIF 0.00000 -0,02506 0.00000 -0.02506 DLWT LOAD 1 2 WLL GLOB X UNIF 0.00000 0.18766 23.16143 0.18766 WLLX LOAD 2 3 LL GLOB Y UNIF 0.00000 -0.15973 0.00000 -0,15973 LIVE LOAD 2 3 DL GLOB Y UNIF 0,00000 -0.02662 0.00000 -0.02662 DEAD LOAD 2 3 DL GLOB Y UNIF 0.00000 -0.01753 0.00000 -0.01753 DLWT LOAD 2 3 WLL GLOB X UNIF 0.00000 -0.02314 28.17296 -0.02314 WLLX LOAD 2 3 WLL GLOB Y UNIF 0.00000 0.27770 �8.17296 0.27770 WLLY LOAD 4 3 LL GLOB Y UNIF 0.00000 -0.15973 0.00000 -0.15973 LIVE LOAD 4 3 DL GLOB Y UNIF 0.00000 -0.02662 0,00000 -0.02662 DEAD LOAD 4 3 DL GLOB Y UNIF 0.00000 -0.01753 0,00000 -0.01753 DLWT LOAD 4 3 WLL GLOB X UNIF 0.00000 0.02314 28.17296 0.02314 WLLX LOAD 4 3 WLL GLOB Y UNIF 0.00000 0.27770 28.17296 0.27770 WLLY L 5 4 DL GLOB Y UNIF 0,00000 -0.02506 0.00000 -0,02506 DLWT LOO 5 4 WLL GLOB X UNIF 0,00000 0.11729 23.16143 0,11729 WLLX END LOAD CONDITION ARRAY 1 DL 100. LL 100. 0. 0. 2 DL 100. WLL 100. 0. 0. 3 DL 100. LL 50. WLL 100. 0. 4 DL 100. WLL 50. LL 100. 0. 5 DL 100. WL2 100. 0. 0. LOAD CONDITION DESCRIPTIONS 1 DEAD + LIVE LOAD 2 DL + WLL 3 DL + 1/2LL + WLL 4 DL + 1/2WLL + LL 5 DL + EQ 0 0 0 0 157 F R A M E D E S I G N D A T A N 11 ding Systems, L.P, O85/EGD - 5 10- 7-99 CONFIGURATION (SYMMETRIC FRAME) ... BUILDING WIDTH = 60.00 FT NUMBER OF SPANS = 1 SPAN WIDTHS (FT) = 60.00 DESIGN BAY SIZE = 12.50 FT LEFT EAVE HEIGHT = 25.00 FT RIGHT EAVE HEIGHT = 25.00 FT LEFT COLUMN SLOPE 0.00 /12 LEFT RAFTER SLOPE 1.00 /12 RIGHT RAFTER SLOPE 1.00 /12 RIGHT COLUMN SLOPE 0.00 112 GIRT DEPTH 8.00 IN PURLIN DEPTH 8.00 IN LOADINGS ... DEAD LOAD = 2.000 PSF LIVE LOAD = 12.000 PSF WIND LOAD = 17,386 PSF WIND LOAD PARAMETERS ... WIND LOAD METHOD = SPEC W&TENSITY = 17.39 PSF 0 M OOF HEIGHT = 25.00 FT WIND LEFT COEFFICIENTS = 0.80 -1.20 -1.20 -0.50 FOR WLL WIND RIGHT COEFFICIENTS = 0.80 -1.20 -1.20 -0.50 FOR WLR LOAD CONDITIONS ... LOAD CONDITION 1 = DEAD + LIVE LOAD LOAD CONDITION 2 = DL + WLL LOAD CONDITION 3 = DL + 1/2LL + WLL LOAD CONDITION 4 = DL + 1/2WLL + LL LOAD CONDITION 5 = DL + EQ 0 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. JOB#1824085/EGD - 5 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 2 - DL + WLL SECTION MEMBER VERTICAL HORIZONTAL JOINT JOINT F * CTIONS AND DEFLECTIONS - LOAD CONDITION 1 - DEAD + LIVE LOAD SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ 1 ------ 1 -------- 6.324 -------- 2.434 -------- 0.000 -------- 0.000 -------- 0.000 2 2 2.085 4 3 -0.004 -0.108 3 0.866 2,003 5 -0.311 -0.062 4 3 1.989 6 4 -1.108 0.000 5 0.075 1.899 7 5 -0.311 0,062 6 4 0.000 -0.004 0.108 7 5 6.324 -2.434 01000 0.000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 2 - DL + WLL SECTION MEMBER VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION NUMBER NUMBER (KIPS) (KIPS) ------ I ------ i -------- -7.414 -------- -6.709 2 2 (KIP -FT) 1.300 3 ------ 1 0.781 1.965 4 3 1,857 0.000 5 0 4 5 -4.585 -0.354 MOMENT VERTICAL HORIZONTAL REACTION DEFLECTION DEFLECTION (KIP -FT) (IN) (IN) -------- 0.000 -------- 01000 ----- 0.000 DEFLECTION -0.069 2.112 NUMBER -0,042 2.109 (KIP -FT) 1.300 2.003 ------ 1 0.781 1.965 -------- -5.760 0.077 1,857 0.000 0.000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 3 - DL + 1/2LL + WLL SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ 1 ------ 1 -------- -5.164 -------- -5.760 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0.071 2.069 3 -0.163 2.085 4 3 0.866 2,003 5 0,659 1.989 6 4 0.075 1.899 7 5 -2.335 -1.304 0.000 0.000 0.000 FRAME REACTIONS AND DEFLECTIONS - LOAD CONDITION 4 - DL + 1/2WLL + LL PAGE NO. - 1 DATE 10- 7-99 ------------------------------------- SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ 1 ------ 1 -------- 1.705 -------- -1.188 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0.038 0.960 0 -0.298 0.999 3 -0.338 11001 5 0.113 1.038 6 4 0,035 1.025 7 ------------------------------------------------------------------------------------------------------------------------ 5 3.120 -2.343 0.000 0.000 0.000 59 m 0 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 2 JOB#1824085/EGD ------------------------------------------------------------------------------------------------------------------------ - 5 DATE 10- 7-99 F ROEA CTIONS AND DEFLECTIONS - LOAD CONDITION 5 - DL + EQ SECTION MEMBER VERTICAL HORIZONTAL MOMENT VERTICAL HORIZONTAL JOINT JOINT REACTION REACTION REACTION DEFLECTION DEFLECTION NUMBER NUMBER (KIPS) (KIPS) (KIP -FT) (IN) (IN) ------ ------ 1 1 -------- 1.624 -------- 0.268 -------- 0.000 -------- 0.000 -------- 0.000 2 2 -0.011 0.234 3 -0.123 0,251 4 3 -0.230 0,258 5 -0.008 0,275 6 4 0.008 0.277 7 5 ------------------------------------------------------------------------------------------------------------------------ 2.025 -0,768 0.000 0.000 0.000 0 0 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 3 JOB#1824085/EGD - 5 DATE 10- 7-99 ------------------------------------------------------------------------------------------------------------------------ EXT MN 1- 2 LENGTH 23.16 FT MEMBER ANGLE 87.84 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 580, LB 10LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD SEC NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 22.07 55, 46.'12 1.84 FT 10.50 IN 30.50 IN 8.000 XO.2500 0.1644 8.000 XO.2500 0,712 19.3 FT 2 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES ­ SECTION FORCE MOMENT FA FBO FBI NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) 1 -8.01 88.92 36.80 19.90 44.00 ------------------------------------------------ RAFTER 2- 3 LENGTH 28.17 FT MEMBER ANGLE --MAXIMUM STRESSES- --UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - (KSI) (KSI) (KSI) AXIAL BENDING BENDING -- COND (KIPS) (KIPS) T -0.94 14.16 -14.16 0.03 0.71 0.32 1 -2'.21 12.32 5.94 DEG TEMP DIFF 0, DEG,F RELEASES 0 WEIGHT 494, LB SECTION LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 7.04 55. 46. 4 1.76 FT 30.38 IN 18.38 IN 6.000 XO.1875 0.1644 6.000 XO.1875 0.667 1.1 FT 2 2 20.00 55. 46, 1-1 1.82 FT 18.38 IN 18.38 IN 6.000 XO.1875 0.1345 6,000 XO.1875 0.604 8.2 FT 2 (CONTROLLING ACTIONS) AXIAL . --ALLOWABLE STRESSES- --MAXIMUM STRESSES- --UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D SECTION FORCE MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING COND (KIPS) (KIPS) T 1 .-3.55 89.81 36.80 27.79 44.00 -0.49 18.55 -18.55 0.01 0.67 0.42 2 -7.27 16.42 2 -3.05 44.31 36.80 32.17 44.00 -0.65 19.43 -19.43 0.02 0.60 0.44 2 -5.86 14.99 ------------------------------------------------------------------------------------------------------------------------ OTER 4- 3 LENGTH 28.17 FT MEMBER ANGLE 174.06 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 494. LB SECTION LENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 7.04 55. 46. 4 1.76 FT 30.38 IN 18.38 IN 6.000 XO.1875 0.1644 6.000 XO.1875 0.474 1.1 FT 1 2 20.00 55. 46. 11 1.82 FT 18.38 IN 18.38 IN 6.000 XO.1875 0.1345 6.000 XO.1875 0.444 25.5 FT 1 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES ­ SECTION FORCE MOMENT FA FBO FBI NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) 1 3.25 -45.15 16.96- 33.00 20.85 2 2.47 22.12 12.61 24.13 33.00 ----------------------------------------------- 0 --MAXIMUM STRESSES- --UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D AXIAL FBO FBI OUTER FL, INNER FL. LOAD FORCE ALLOW, - (KSI) (KSI) (KSI) AXIAL BENDING BENDING CONP (KIPS) (KIPS) T 0.45 -9.32 9.32 0.03 0.28 0.45 1 5.07 12.32 0.53 9.70 -9.70 0.04 0.40 0.29 1 3.87 11.24 0 D E S I G N S U M M A R Y R E P 0 R T NCI Building Systems, L.P. PAGE NO. - 4 JOB#1824085/EGD - 5 DATE 10- 7-99 E'T MN 5- 4 LENGTH 23.16 FT MEMBER ANGLE 92.16 DEG TEMP DIFF 0. DEG.F RELEASES 0 WEIGHT 580. LB SEOCIULENGTH YIELD NO. SEGMENT DEPTH AT DEPTH AT OUTER FLANGE WEB MAX COMB AT LOAD NO. (FT) FLG WEB SEG SIZE START END OR PIPE SECTION THICKNESS INNER FLANGE UNITY CK DIST COND 1 22.07 55. 46. 12 1.84 FT 10.50 IN 30.50 IN 8.000 XO.2500 0.1644 8.000 XO.2500 0.618 22.1 FT 1 (CONTROLLING ACTIONS) AXIAL --ALLOWABLE STRESSES- --MAXIMUM STRESSES --- -- UNITY CHECK COMPONENTS -- ---- WEB SHEAR ------ D SECTION FORCE MOMENT FA FBO FBI AXIAL FBO FBI OUTER FL. INNER FL. LOAD FORCE ALLOW. - NO. (KIPS) (KIP -FT) (KSI) (KSI) (KSI) (KSI) (KSI) (KSI) AXIAL BENDING BENDING --COND (KIPS) (KIPS) T 1 5.86 -48.64 4.62 33.00 14.% 0.66 -6.93 6.93 0.14 0.21 0.48 1 -2.'21 12.32 ------------------------------------------------------------------------------------------------------------------------ TOTAL FRAME WEIGHT IS 2149. LB 0 63 F L A N G E B R A C E R E P 0 R T Me NCI Building Systems, L.P. JO#O85/EGD - 5 E FLANGE BRACING = N PAGE NO. - 1 DATE 10- 7-99 COLUMN 1 - 2 UNBRACED RAFTER 2 - 3 PURLINS LOCATED AT 3.03FT 8.05FT 13,07FT 18.08FT 23.10FT 27.17FT 28.18FT BRACED AT x x x x x RAFTER 4 - 3 PURLINS LOCATED AT 3.03FT 8.05FT 13.07FT 18.08FT 23.1OFT 27.17FT 28.18FT BRACED AT x x x x x COLUMN 5 - 4 ---------------------------------------------------------------------------------------------------------------------- UNBRACED 0 0 W -W PITI SURGH TESTING LABORATORY G 5 CATAPLjjqj= lost :C 14so LANE AVE ?IVE NCRTR, JACKS ON -0 LL.E. FLOFIDA A9 A MV -AL "O'rZZ---?Cb6 ?= Zt-CWTV. TH9 rVILIC AX2 ZLXtx=y". ALjL S%:2 -4;r7= AS PXC1'=XTT CP CL:T-MT2. AXZP AUTMOItf- .7 XTS C) MAT104 Id -.4 T 41 co"'. -LUZOOP42 �* "-.jtAC-r3 V�cw 0:4 3t,=JL =:.a :& P-=X=yC-3 PZ1f=3"Z Z%:31 WjtlT-Z11 AppXMV^#- 'kFE--% CODE M -N) 7&3-4300 TH EHS ST�LUND EYT-3OLT MIN. ASSF�XMLY Cat. No. AS-fj,-A05- Size Breaking rtrenzt%- Ucun- ds) .:vJC 250 BA 114 6,650 FW C 312 BA J 5/1611 511811 li,*200 F rWC 375 BA 3/8" 5/811 15,400' F-qC 437 EA 7116' 11411 20,800 F4C 500 BA 1/211 718" 25,9C.0 Tests L;P-re Conducted using the Flo-Lo'c SL'&:a-,.d 'FW C E S strand and -rVC eyebolts as set forth in the above' table with all. test'ed ;-'Ssemblies Providing at least. 100% of the strand rated breaking load per ASIX -A4 75. Certified PITTSBURGH TEISJING LA.=-O'.qA-, HQ- 2677� 6112 �, Charles L. Moore,. P E ID16 C? R *:.-,qc guarantees that all cress brace assemblie's fabricated in -a.ccordance %�iLh the A-zve tzblc will meet pr exceed the specified M,inimum assembly lorca.king strength. Revision Date: August 12, 1998 File: cAengrform\section properties of ceesi.doc Y NOTES: Section properties and allowables are computed in accordance vAth the 1986 edition of the AISI specifications vAth 1989 addendum. 0 1, and Iyare for deflection determination x x 0 So and Sy are for bending R=. 1875 6 Fy = 57.0 KSI 0 Fu = 70.0 KSI Y GENERALDATA SECTION PROPERTIES Section Name DIMENSIONAL PROPERTIES ALLOWABLES AXIS X -X AXIS Y -Y DxB Thick Weight Area Lip. ma V, ix SX6 Rx ly Sys (in') Ry (in) on) Gage (in) lb/If (in2) (in) (it - k) (kips) (W) (W) (in) (in4) 8 x 2.5 C16 8 x 2.5 16 01.059 2.996 0.822 0.773 4.744 2.332 7.791 1.668 3.078 0.675 0.335 0.906 8 x 2.5 C15 8 x 2.5 15 0.065 3.080 0.906 0.788 5.415 3.124 8.566 1 1.904 3.075 0.743 0.375 0.906 0.070 3.317 0.976 0,800 5.827 3.907 9.210 2.049 3.072 70.8=00 0 4=0 8 0.906 8 x 2.5 C14 8 x 2.5 14 8 x 2.5 C13 8 x 2.5 13 0.085 4.028 1.185 0.836 7.683 7.023 11.126 2.701 3.065 0.970 0.511 0.905 8 x 2.5 C12 8 x 2.5 12 0.105 4.976 1.463 0.885 9.705 12.661 13.649 3.412 3.054 1.196 0.649 0.904 10 x 2.5 C16 10 x 2.5 16 0.059 3.197 0.940 0.773 5.863 1.842 13.256 2.061 3.755 0.719 0.336 0.*875 10 x 2.5 C15 0 x 2.5 15 0.065 3.522 1.036 0.788 6.830 2.466 14.582 2.401 3.752 0.792 0.376 0.874 10 x 2.5 C14 10 x 2.5 14 0.070 3.793 1,116 0.800 7.608 3.083' 15.685 2.675 3.750 0.853 0.410 0.874 10 x 2.5 C13 10 x 2.5 13 0.085 4.606 1.355 .0.836 10.489 5.538 18.973 3.688 3.742 1.035 0.513 0.874 10 x.2.5 C12 10 x 2.5 12 0.105 5.690 1.673 0.885 13.263 10.483. 23.316 4.663 3.733 1.277 .10.654 0.874 12 x 2.5 C16 12 x 2.5 16 0.059 3.598 1.058 0.773 6.997 1.522 20.601 2.460 4.412 0.754 0.337 0.844 -12 X 2.5 C15 12 x 2.5 15 0.065 3.964 1.166 0.788 8.119 2.037 22.670 2.855 4.410 0,830 - 0.377 0.844 12 x 2.5 C14 12 x 2.5 14 0. 070 4.269. 1.256 0.800 9.014 2.546 24.391 3.169 4.407 0.894 0.411 0.844 12 x 2.5 - C'13 12 x 2.5 13 0.085 5.184 1.525 0.836 13.385 4.571 29.529 4.706 1 4.401 1.085 0.515 0.844 12 x 2.5 12 0.105 6.404 1.883 0.885 17.222 8.646 36,329T 2 1.340 0.657 1 0.843C4 _M 12 x 2.5 C12 1 1 Revision Date: August 12, 1998 File: cAengrform\section properties of ceesi.doc 0 �, 0 y t x .1875 y Section Name D x B (I n) 14 x 2.5 C16 14 x 2.5 GENERAL DATA DIMENSIONAL PROPERTIES Thick Weight Gage (i n) lb / If 16 0.059 4.000 Area (in2) 1.176 Lip _l(in) 0.773 ALLOWABLES Ma Va (ft - k) (kips) 8.144 1.296 NOTES: Section properties and allowables are computed in accordance %vilh the 1986 edition of the AISI specifications Witt 1989 addendum. 0 1. and ly are for deflection determination 0 So and Sy are for bending 0 Fy = 57.0 KSI 0 Fu = 70.0 KSI SECTION PROPERTIES AXIS X -X AXIS Y -Y Ix SX0 Rx it Sy. Ry (in4) (in3) ___LnL_ (in') (in3) (in) 30.063 2.863 5.055 0.781 0.337 0.815 14 x 2.5 CIS 14 x 2.5 15 0 . .065 4.406 1.296 0.788 9.427 1.735 33.089 3.314 5.053 0.861 0.378 0.815 4.745 1.396 0.800 10.444 2.169 35.608 3.672 5.051 0.927 0.412 0.815 14 x 2.5 C14 14 x 2.5 14 0.070 5.762 1.695 0.836 15.347 3.891 43.134 5.396 5.045 1.126 0.516 0.815 14 x 2.5 C13 14 x 2.5 13 0.085 14 x 2.5 C12 14 x 2.5 12 0.105 7.118 2.093 0.885 21.580 7.357 53.110 7.587 5.037 1.390 0.659 0.815 Revision Date: August 12, 1998 File: Oengrform\sectlon properties of cees2.dSbl 0 - A, 0 y t x x 1875 Section Name DxB on) 8 x 3.5 C16 8 x 3.5 GENERALDAT DIMENSIONAL PROPERTIES Thick Weight Gage (in) lb / If 16 0.059, 3,197 . A Area 00) 0.940 Lip (in) 0.773 ALLOWABLES I mo vo (ft - k) (kips) 4.870 2.332 NOTES: Section properties and alloWables.are computed in accordance vAth the 1986 edition of the AISI specifications Wilt 1989 addendum. I, and ly are for deflection determinaltion 0 So and Sy are for bending 0 Fy = 57.0 KSI 0 Fu = 70.0 KSI SECTION PROPERTIES AXIS X -X AXIS Y -Y --- ix SX6 Rx ly Sye Ry (in4) (in3) (in) (0) (in3) (in) 9.652 1.712 3.204 1.523 0.548 1.273 8 x 3.5 C15 8 x 3.5 15 0.065 3.522 1.036 0.787 5.714 3.124 10.612 2.009 3.201 1.678 0.614 1.273 8 x 3.5 C14 8 x 3.5 14 0.070 3.793 1.116 0.800 6.402 3.907 1`1.411 2.251 3.198 1.808 0.670 1.273 8 x 3.5 C13 8 x 3.5 13 0.085 4.606 11.355 0.836 8.092 7.023 13.789 2.845 3.190 2.196 0.841 1.273 5.690 1.673 0.885 10.164 12.661 16.921 3.574 3.180 2.712 1.074 1.273 8 x 3.5 C12 8 x 3.5 12 0.105 0.059 3.598 1'.058 0.773 6.071 1.842 16.171 2. - 134 3.909 1.633 0.550 1.242 110 x 3.5 C16 10 x 3.5 16 10 x 3.5 C15 10 x 3.5 15 0.065 3.964 1.166 0.787 7.1102 2.466 17.790 2.497 3.906 1.800 0.617 1.243 10 x 3.5 C14 10 x 3.5 14 0.070 4.269 1.256 0.800 8.033 3.083 19.136 2.824 3.904 1.939 0.673 1.243 10 x 3.5 C13 10 x 3.5 13 0.085 5.184 1,525 0.836 11.022 5.538 23.151 3.875 3.897 2.356 0.845 1.243 10 x 3.5 C12 10 x 3.5 12 0.105 6.404 1.883 0.885 13.827 10,483 28.456 4.861 -3.88.7 2.912 '.1:.082 1.243 0.059- 4.000 1.176 0.773 7.279 1.522 24.808 2.559 4.592 1.721 0.552 1.210 12 x 3.5 C16 12 x 3.5 16 0.065 4.406 1.296 0.787 8.494 2.037 27.299 2.986 4.590 1.897 0.618 1.210 12 x 3.5 C15 12 x 3.5 15 0.070 4.745 1.396 0.800 9.586 2.546 29.372 3.370 4.588 2.044 0.675 1.210 12 x 3.5 C14 12 x 3.5 14 1120. C13 12 x 3.5 13 0.085 5.762 1.695 0.836 13.294 4.571 35.563 4.674 4.581 2.484 0.849 1.211 12 0.105 7.118 2.093 0.885 17.900 8.646 43.758 6.293 4.572 r3.071 1.088 _ 1.211 12.x 3.5 C 12 12 x 3.5 Revision Date: August 12, 1998 CO - File: Oengrform\sectlon properties of ceesIdoc y x 1875 y Section Name DxB (i n) GENERAL DATA DIMENSIONAL PROPERTIES Thick Weight Gage (in) lb / It Area (in2) Lip (in) ALLO ABLES Ma V3 (ft - k) (kips) NOTES: Section properties andallowables are computed in accordance vAth the 1986 edition of the AISI specifications vAth 19 89 addendum. 0 Ir and Iyare for deflection determination 0 So and Sy are for bending 0 Fy = 57.0 KSI Fu = 70.0 KSI SECTION PROPERTIES AXIS X -X I . AXIS Y -Y ix SX8 - Rx ly Sye R, (W) (W) (in)___ (W) (in3) (in) 14 x 3.5 C16 14 X 3.5 16 0.059, 4.401 1.294 0.773 8.489 1.296 35.797 2.985 5.259 1.793 0.552 1.177 4.848 1.426 0.787 9.8.93 1.735 39.399 3.478 5.257 1.976 0.619 1.177 14 x 3.5 C15 14 x 3.5 15 0.065 14 x 3.5 C14 14 x 3.5 14 0.070 5.221 1.536 0.800 11.148 2.169 42.400 3.920 5.255 2.130 0.676 1.178 14 x 3.5 C13 14 x 3.5 13 0.085 6.340 1.865 0.836 15.370 3.891 51.364 5.404 5.248 2.589 0.851 1.178 0.105 7.832 2,303 '0.885 21.533 7.357 63.246 7.571 5.240 3.202 1.091 1.179 14 x 3.5 C12 14 x 3.5 12 Revision Date: August 12, 1998 File: c:\engrform\section properties of cees4.doc n cz y NOTES: Section properties and allowables are computed In accordance vAth the I t 1986 edition of the AISI specifications vvith 1989 addendum. 0 Ir and Iyare for deflection determination x x 0 So and Sy are for bending R .1875 0 Fy = 57.0 KSI 0 Fu = 70.0 KSI Section Name GENERAL DATA DIMENSIONAL PROPERTIES ALLOWABLES SECTION PROPERTIES AXIS X -X AXIS Y -Y DxB On) Gage Thick (in) Weight lb/If Area (in2) Lip (in) ma (ft - k) vo (kips) Ix (W) Sxe (in3) R, (in) 1, 60) Sye (in3) R, (in) 8 x 3.5 C16 (2) 8 x 3.5 16 0.059 6.394 1.881. 0.773 9.739 4.665 19.303 3.424 3.204 5.133 0.963 1.652 8 x 3.5 C15 (2) 8 x 3.5 15 0.065 7.044 2.072 .0.787 11.728 6.248 21.225 4.018 3.201 5.674 1.078 1.655 8 x 3.5 C14 (2) 8 x 3.5 14 0.070 7.586 2.231 0.800 12.803 7.814 22.822 4.501 3.198 6.130 1.178 1.65 - 8 x 35 C13 (2) 8 x 3.5 13 0.085 9.212 2.709 0.836 16.183 14.046 27.578 5.690 3.190 7.506 1.502 1.664 8 x 3.5 C12 (2) 8 x 3.5 12 0.105 11.3794 3.347 0.885 20.329 25.320 33.843 7.147 3.180 9.374 1.971 1.674 Revislo . n Date: August 12, 1998 File: c:\engrform\section properties of ceesS.doc Ll 0 0 Revision Date: August 12, 1998 File: c:\engrform\sectlon properties of eave struts.doc y NOTES: 12 Section properties and allowables are computed in accordance vAh the 1986 edition of the AISI specifications vAth 1989 addendum. 0 1, and ly are for deflection determination x 0 So and Sy are for bending 12 0 Fy = 57.0 KSI Fu = 70.0 KSI GENERALDATA SECTION PROPERTIES Section Name DIMENSIONAL PROPERTIES ALLOWABLES AXIS X -X AXIS Y -Y D x Bl x B2 Thick Weight Area Lip, ma V. SX8 Rx 1, Sye R, (i n) Gage (in) lb/If (in2) (in) (it - k) (kips) (W) (in) (0) (in3) (in) 8ES16 8 x 3.375 x 5 16 0.059, 3.598 1.058 1.0.88 5.377 2.350 1 10.936 1.890 3.215 2.902 0.717 1.656 8ES14 8 x 3.*375 x 5 14 0.070 4.269 1.256 1.114 7.109 3.937 12.924 2.499 3.208 3.440 0.876 1.655 8ES12 8 x 3.375 x 5 12 0.105 6.404 1.883 1.200 11.379 12.754 19.143 4.001 3.188 5.142 1.408 1.653 10ES16 10 x 3.375 x 5 16 0.059 4.000 1.176 1.088 .6.803 1.853 18.319 2.392 3.946 3.117 0.719' 1.628 IOES14 10 x 3.376 x 5 14 0.070 4.745 1.396 1.114 8.991 3.102 21.670 3.161 3.941 3.697 0.880 -1.628 iOES12 10 x 3.375 x 5 12 0.105 7.118 2.093 1.200 15.523 10.546 32.195 5.458 3.922 5.537 1.422 1.626 12ES16 12 x 3.375 x 5 16 0.059 4.401 1.294 1.088 8.233 1.529 28.050 2.895 4.655 3.294 0.721 1.595 12ES14 12 x 3.375 x 5 14 0.070 5.221 1.536 1.114 10.852 2.559 33.201 3.815 4.650 3.907 0.883 1.595 12ES12 12 x 3.375 x 5 12 0.105 7.832 2.303 1.200 20.305 8.689 49.422 7.067 4.632 5.855 1.430 1.594 14ES16 14 x 3.375 x 5 16 0.059 4.802 1.412 1.088 9.666 1.302 40.364 3.398 5.346 - 3.441 0322 1.561 14ES14 14 x 3.375 x 5 14 0.070 5.697 1.676 1.114 12.719 2.178 47.793 4.472 5.341 4.082 0.886 1.561 14 x 3.375 x 5 12 0.105 8.546 2.513 1.200 23.887 7:388 71.250 8.398 5.324 6.120 1.436 1.560 Revision Date: August 12, 1998 File: c:\engrform\sectlon properties of eave struts.doc 0 0 y 81 NOTES: 17 Section properties an d* allowables are computed in accordance with the 1986 edition of the AISI specifications with 1989 addendum. x x 0 Ix and Iyare for deflection determination 0 Se and Sy are for bending a Fy = 57.0 KSI 92_4 0 Fu = 70.0 KSI GENERAL DATA SECTION PROPERTIES Section Name DIMENSIONAL PROPERTIES ALLOWABLES AXIS X -X AXIS Y -Y D x B1 x B2 Thick Weight Area Lip Ma va Ix 7 77.759 SX6 Rx Sys R, (in) Gage (in) lb / If (in) (ft - k) _(kips) i n' (W) (in) (in4) _(in3) (in) 8 x 2Z16 8 x 2.125 x 2.375 16 0.059 2.796 0.822 0.911 4.970 2.332 1.747 _3.072 1.081 0.338 1.146 8 x 2Z15 8 x 2.125 x 2.375 15 0.065 3.080 0.906 0.922 5.599 3.124 8.534 1.969 3.069 1.194 0.388 1.148 8 x 2Z14 8 x 2.125 x 2.375 14 0.070 3.317 0.976 0.930 6.078 3.907 9 .177 2.137 3.067 1.289 0.429 1.150 8 x 2Z13 8 x 2.125 x 2.375 13 0.085 4.028 1.185 0.956 7.749 7.023 11.095 2.724 3.060 1.577 0.544 1.154 8 x 2Z12 8 x'2.125 x 2.375 12 0.105 4.976 1.463 0.990 9.519 12.661 13.624 3.347 3.051 1.967 0.678 1.160 10x2Z16 10 x 2.125 x 2.375 16 0.059 3.197 0.940 0.911 6.154 1.842 13.215 2.164 1 3.749 1.081 0.338 1.072 10 x 2Z15 10 x 2.125 x 2.375 15 0.065 3.522 1.036 .0.922 7.214 2.466 14.541 2.536 3.747 1.195 0.388 1.074 10 x 2Z14 10 x 2.125 x 2.375 14 0.070 3.793 1.116 0.930 8.130 3.083 115.642 2.858 3.745 1.290 0.428 1.075 10x2Z13 10 x 2.125 x 2.375 13 0.085 4.606 1,355 0.956 10.600 5.538 18.933 3.727 3.738 1.578 0.544 1.079 10 x 2Z12 110 x 2.125 x 2.375 12 0.105 5.690 1.673 0.990 13.043 10.483 23.285. 4.586 3.730. 1.968 0!'676 1.085 Revision Date: August 12, 1998 File: c:\engrform\section properties of zeel.doc 0 E y NOTES: Section properties and allowables are computed in accordance vvith the 1986 edition of the AISI specifications vAlh 1989 addendum. x x 0 1,, and Iyare for deflection determination I a So and Sy are for bending J, 0 Fy = 57.0 KSI �132 Fu = 70.0 KSI GENERALDATA, SECTION PROPERTIES Section Name DIMENSIONAL PROPERTIES ALLOWABLES AXIS X -X AXIS Y -Y D x 1311 x B2 Thick Weight Area Lip M, va ix SX0 Rx 11 Sys R, (n) Gage (in) 1b, / If (in2) (in) (ft - k) (kips) (W) (W) (in) (W) (in3) (in) 10 x 3Z16 10 x 3.125 x 3.375 16 0.059 3.598 1.058 '0.911 6.348 1.842 16.131 2.232 3.904 2.582 0.488 1.562 10 x 3Z15 10 x 3.125 x 3.375 15 0.065 3.946 1.166 0.922 7.361 2.466 17.749 2.588 3.902 2.852 0.532 1.564 10 x 3Z14 10 x 3.125 x 3.375 14 0.070 4.269 1.256 0.930 8.269 3.083 19.094 2.907. 3.900 3.077 0.570 1.566 10x3z13 10 x 3.125 x 3.375 13 0.085 5.184 1.525 0.956 11.185 5.538 23.112 3.933 3.893 3.759 0.698 1.570 10 x V12 10 x 3.125 x 3.375 12 0.105 6.404 1.883 0.990 14.029 10.483 28.427 4.932 3.885 4.681 0.956 1.577 12 x 3Z16 12 x 3.125 x 3.375 16 0.059 4.000 1.176 0.911 7.608 1.522 24.759 2.675 .4.588 2.583 0.490 1.482 12 x 3Z15 12 x 3.125 x 3.375 15 0.065 4.406 1.296 0.922 8.806 2.037 27.250 3.096 4.586 2.852 0.534 1.484 12 x 3Z14 12 x 3.125 x 3.375 14 0.070 4.745 1.396 0.930 9. 869 2.546 29.321 3.470 4.584 3.078 0.573 1.485 12 x 3Z13 12 x 3.125 x 3.375 13 0.085 5.762 1.695 0,956 13.462 4.571 35.515 4.733 4.518 3.760 0.701 1.490 12 x 212 12 x 3.125 x 3.375 12 0.105 7.118 2.093 0.990 18.129 8.646 43.722 6.374 4.570 4.682 0.959 1.495 14 x 3Z16 14 x 3.125 x 3.375 16 0.059. 4.401 1.294 0.bi 1 8.873 1.296 35.739 3.120 5.255 2.583 0.490 1.413 14 x 3Z15 14 x 3.125 x 3.375 15 0.065 4.848 1.426 0.922 10.256 1.735 39.342 3.606 5.253 2.853 0.535 1.414 14 x 3Z14 14 x 3.125 x 3.375 14 0.070 5.221. 1.536 0.930 11.479 2.169 42.339 4.036 5.251 3.078 0.575 1.416 14 x 3Z13 14 x 3.125 x 3.375 13 0,085 6.340 1.865 0.956 15.572 3.891 51.307 7.240 5.246 3.760 0.704 1.420 14 x -3Z12 14 x 3.125 x 3.375 12 0.105 7.832 2.303 0 9=9 0 22.092 i 7.357 [ 63.204 7.767 i 5.238 4.682 0.961 1.426 Revlslon Date: Auqust 12, 1998 File: c:\engrform\secllon properties of zee2.doc 0 0 0 Revislon Date: August 12, 1998 Flle: c:\engrform\section propertles of panels - 12-wr.doc --I 4ti 12* NET COVERAGE NOTES: 2 5/16" 7318' 25111" The panel section properties have been calculated in accordance with the 1986 edition of the AISI specifications with 1989 addendum. 131160 7/86 5/8' Ix Is for deflection deten-nination Sx Is for bending Ma Is allowable bending moment The pan*el weight has been deducted from the allowable loads Values shown for wind load deflection are limited by a maximum deflection ratio of L/I 20 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress 12" "WR" Panel values shown by 0.8 for 2 span conbitions Load table values do not include web crippling requirements PANELPROPERTIES . PANEL'TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) GA. Desig n Thickness Weight Fy SX Ma I, SX I Ma (i n) (pso (ksi) In4 / ft In3/ft in -kip ft In' / ft in3/ft in -kip R 24 0.0223 1.34 50.0 0.3276 0.1471 4.40 0.2010 0.1090 3.26 22 0.0286 1.72 50.0 0.4225 0.1907 1 5.71 0.2772 1 0.1459 4.37 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 24GAUGE 22 GAUGE Span In Feet Live Load Stress Live Load Deflection Live Load Stress Live Load Deflection 4.0 158 681 211 -901.:: 5.0 100 348 134 461 6.0 69 202 93 267 7.o 51. 127 68 168 Revislon Date: August 12, 1998 Flle: c:\engrform\section propertles of panels - 12-wr.doc --I 4ti 0 0 Revision Date: August 12, 1998 Fife: c:\engrform\section properties of panels - 18-wr.doc NOTES: '181ETCOVERAGE The panel section properties have been calculated in accordance wilh the 1986 edition of the AISI specifications with 2 5/16* 13 318" 2 5116' 1989 addendum. 13116' 7/82 0 IX is for deflection determination 3/16, 51 4 31`16 0 Sx is for bending Z-- M. Is allowable bending.moment The panel weight has been deducted from the allowable loads Values shown for wind load deflection are limited by a maximum deflection ratio of L/1 20 Allowable load values shown are based on panel covering 3 equal continuous spans. Mulliply allowable stress 18" "WR" Panel values shown by 0.8 for 2 span conditions Load table values do not include web crippling requirements PANEL PROPERTIES PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) Design Thickness Weight GA. Fy IX SX Ma IX SX M8 On) (pso (ksi) In4 / ft in3/ft In -kip / ft In4 / ft in3 / ft in -kip R 24 0.0223 1.22 50.0 0.2599 0.1057 3.17 0.1349 0.0749 2.18 22 0.0286 1.56 50.0 0.3354 0.1379 1 4.13 0.1867 0.0976 2.92 ALLOWABLE 24GAUGE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 22 GAUGE Span In Feet Live Load Stress Live Load Deflection Live Load Stress Live Load Deflection 4.0 105 508 141 672 .5.0 67 260 90 344 6.0 46 151 62 199 7.0 33 95 45 125 Revision Date: August 12, 1998 Fife: c:\engrform\section properties of panels - 18-wr.doc 0 Revision Date: August 12, 1998 File: 0engrform\section properties of panels - 24 - wr.doc 24' NET COVERAGE NOTES: 2 5116' 19318, 2 5116' The panel section properties have been calculated in accordance with the 1986 edition of the AISI specifications with 1989 addendum. 13/1 6 518. 7181 0 Ix Is for deflection determination 6 M61 6" 7' 6 3/1_, 0 Sx is fot bending 0 Ma Is allowable bending moment loads 0 The panel weight has been deducted from the allowable 518, 0 Values shown for wind load deflection are limited by a maximum deflection ratio of Ul 20 24""WR"Panel 0 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress values shown by 0.8 for 2 span condifigns 0 Load (able values do not include web crippling requirements PANEL PROPERTIES PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) GA. Design Thickness Weight Fy 11 S, M IX SX M, On) (pso (ksi) In' / ft In'/ it in-kl�/ it In4 / it in3 / ft in -kip it 24 0.0223 1.16 50.0 0.2129 0.0814 2.44 0.1014 0.0547 1.64 22 0.0286 1.49 50.0 0.2749 0.1075 3.22 0.1406 0.0733 2.20 M ALLOWABLE 24 GAUGE UNIFORM LOADS IN POUNDS PER SQUARE FOOT' 22 GAUGE S pan In Feet Live Load Stress Live Load Deflection Live Load Stess Live Load Deflection 4.0 79 405 105 535:: 5.0 50 207 67 274 6.0 34 120 46 159 7.0 25 76 33 100 Revision Date: August 12, 1998 File: 0engrform\section properties of panels - 24 - wr.doc levislon Date: August 12, 1998 File: 0Pnnrl`nrm\sP.rA inn nrnnprtip- nf n;;nPle - ;i rinr 112' Cn 36* NET COVERAGE 12' 1, 2 5/16" —1 4� "A" Panel 12* 6' f 6 NOTES: The panel section properties have.been calculated in accordance wil . h the 1986 edition of the AISI specifications with 1989 addendum. Ix is for deflection determination Sx is for bending 0 M. Is allowable bending moment 0 The wind load stress values have been increased by 33 1/3% a Values shown forwind load deflection are limitedby a maximum deflection ratio of U120 0 Allowable load values shown are based on panel covering 3 equal continuous spans. Mulliply allowable stress values shown by 0.8 for 2 span conditions 0 This panel is to be used as wall panel only PANEL PROPERTIES GA. Design Thickness Weight (in) (pso Fy (ksi) PANEL TOP IN COMPRESSION (Fy) Ix S, ma In' / it in3/ft in -kip / it PANEL BOTTOM IN COMPRESSION (Fy) IX In' / it SX 10 / R ma in -kip / it 26 0.0181 0.911 80.0 0.0187 0.0275 0.99 0.0248 0.0365 1.31 24 0.0223 1.13 50.0 0.0273 0.0377 1.13 0.0319 0.0477 1.43 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT Span In Feet 26 GAUGE 24 GAUGE Wind Load Pressure Wind Load Suction Wind Load Deflection Wind Load Pressure Wind Load Suction Wind Load Deflection 4.0 85 64 84 93 73 114 5.0 54 41 43 59 47 59 6.0 38 29 25 41 33 34 7.0 28 21 16 30 24 21 8.0 21 16 10 23 18 14 levislon Date: August 12, 1998 File: 0Pnnrl`nrm\sP.rA inn nrnnprtip- nf n;;nPle - ;i rinr 0 Ll 0 Revision Date: August 12, 1998 File: cAengrforrn\seclion properties of panels - arn.doc -j on 3V NET COVERAGE NOTES: Ir jr I? The panel section properties have been calculated in accordance wilh the 1986 edition of the AISI specifications with r 1989 addendum. 0 Ix is for deflection determination 3 Iff r 0 & is for bending 0 Me Is allowable.bending moment SCREW GROOVE 0 The wind load stress values have been increased by 33 113% 0 Values shown for wind load delleclion are limited by a maximum deflection ratio of U120 "AM" Panel 0 Allowable load values shown are based on panel covering 3 equal continuous spans. Mulliply allowable stress values shown by 0.8 for 2 span cofiditions a This panel Is to be used as wall panel only PANEL PROPERTIES Design Thickness Weight Fy PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) GA. (I n) (Pso (ksi) Ix Sx Ma Ix S, Ma In4 / it In3/ft in -kip R In4 / it in3 / ft in -kip it 26 0.0181 0.91 80.0 0.0451 0.0522 1.87 0.0388 0.0365 1.31 24 0.0223 1.12 J 50.0 0.0555 0.0643 1.92 0.0536 0.0536 1.60 ALLOWABLE UNIFORM LOAD$ IN POUNDS PER SQUARE FOOT 26 GAUGE 24 GAUGE Span In Feet Wind Load Pressure Wind Load Suction Wind Load Deflection Wind Load Pressure Wind Load Suction Wind Load Deflection 4.0 85 114 162 104 125 210 5.0 54 73 83 67 80 108 6.0 38 51 48 46 56 62 7.0 28 37 30 34 41 39 8.0 21 28 20 26 31 26 F Revision Date: August 12, 1998 File: cAengrforrn\seclion properties of panels - arn.doc -j on Revision Date: June 16, 1998 File: c:\engrform\section properties of panels - pbr.doc:Z 36*NETCOVERAGE NOTES: 12' 12 12* 314, 41 4. The panel section properties have been calculated in accordance with the 1986 edition of the AISI specifications with 1989 addendum. 5i n 1. is for deflection determination 3 "117 J�l 318- S. is for bending Ma is allowable bending moment 6 The panel weight has been deducted from the allowable loads "PBR" Panel 0 The wind load stress values have been increased by 33 1/3% * Values shown for wind load deflection are limited by a maximum deflection ratio of U120 6 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress values shown by 0.8 for 2 span conditions * Load table values do not include web crippling requirements PANEL PROPERTIES GA. Design Thickness Weight (in) (pso Fy (ksi) PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) 11 10 / it Sx in3 / ft Ma Ix in -kip / ft In4 / ft S, in3 / ft Ma in -kip R 26 0.0181 0.92 80.0 0.0425 0.0379 1.36 0.0414 0.0502 1.80 24 0.0223 Y 1.14 50.0 1 0.0596 1 0.0571 1 1.71 1 0.0573 i 0.0644 1 1.93 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 26 GAUGE 24 GAUGE Span In Feet Wind Load Uplift Live Load Stress Live Load Deflection Wind Load Uplift Live Load Stress Live Load Deflection 4.0 89 87 108 112 93 151 5.0 57 55 55 72 59 77 6.0 40 38 32 50 41 45 7.0 30 28 20 37 30 28 8.0 23 21 14 29 22 19 Revision Date: June 16, 1998 File: c:\engrform\section properties of panels - pbr.doc:Z 7-- W NET COVERAGE NOTES: 12' 1? 314' 4' 4. The panel section properties have been calculated in accordance with the 1986 edition of the AISI specifications with 1989 addendum. IT I� Is for deflection determination 1318' 0 % is for bending 0 Ma is allowable bending moment 0 The panel weight has been deducted from the allowable loads "R" Panel 0 The wind load stress values have been increased by 33 1/3% 0 Values shown forwind load deflection are limitedby a maximum deflection ratio of U120 0 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress values shown by 0.8 for 2 span conditions 0 Load table values do not include web crippling requirements PANEL PROPERTIES GA. Design Thickness (in) Weight (pso Fy (ksi) PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) SX ma SX Ma In4/ft in3 / ft in -kip / R In4 / ft in3/ft in -kip / ft 26 0.0181 0.92 80.0 0.0425 0.0379 1.36 0.0414 0.0502 1.80 24 0.0223 1.14 50.0 0.0596 0.0571 1.71 0.0573 0.0644 1.93 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT Span in Feet I 26GAUGE 24GAUGE i Wind Load Uplift Live Load Stress Live Load Deflection Wind Load Uplift Live Load Stress Live Load Deflection 4.0 89 87 108 112 93 151 5.0 57 55 55 72 59 77 6.0 40 38 32 50 41 45 7.0 30 28 20 37 30 28 8.0 23 21 14 29 22 19 Revision Date: August 12, 1998 File: c:\engrform\section properties of panels - r.d6-;t,- Revision Date: August 12, 1998 File: c:\engrform\seclion properties of panels - ss216.doc IVNETCOVERAGE NOTES: 3/4' 4. 4. 4. 4. The panel section properties have been calculated in accorclance*wilh the 1986 edition of the AISI specifications with 1989 addendum. Ix Is for deflection determination Sx is for bending Ma Is allowable bending moment The panel weight has been deducted from the allowable loads 0 Values shown for wind load deflection are limited by a maximum deflection ratio of U120 "SS216" Panel 0 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress values shown by 0.8 for 2 span colhditions Load table values do not Include web crippling requirements PANEL PROPERTIES GA. Design Thickness Weight (in) (pso Fy (ksi) PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) IX SX ma 11 SX ma 10 / ft in3 / ft in -kip / It In4 / ft in3 / ft in -kip ft 24 0.0223 1.29 50.0 0.1332 0.0739 2.21 0.0637 0.0584 1.75 22 0.0286 1.66 50.0 0.1712 0.1023 3.06 0.0905 0.0796 2.38 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE F70T Span In Feet 24 GAUGE 22 GAUG� Live Load Stress Live Load Deflection Live Load Stress Live Load Deflection 4.0 84 254 114 337 5.0 53 130 73 173 6.0 37 75 50 100 7.0 27 47 36 63 _F_ Revision Date: August 12, 1998 File: c:\engrform\seclion properties of panels - ss216.doc Revlslon Date: August 12, 1998 File: c:\engrform\section properties of panels - u.doc XNETCOVERAGE NOTES: 6- 6. 68 6- 6 - The panel section properties have been calculated in accordance with the 1986 edition of the AISI specificafions with 1989 addendum. 6 is for deflection determination "21 13 1/? Sx is for bending M. is allowable bending moment * The panel weight has been deducted from the allowable loads "U" Panel * The wind load stress values have been increased by 33 1/3% Values shown for wind load deflection are limited by a maximum deflection ratio of L/1 20 Allowable load values shown are based on panel covering 3 equal continuous spans. Multiply allowable stress values shown by 0.8 for 2 span conditions Load table values do not include web crippling requirements PANEL PROPERTIES Design Thic . kness Weight Fy PANEL TOP IN COMPRESSION (Fy) PANEL BOTTOM IN COMPRESSION (Fy) GA. (i n) (pso (ksi) Ix Sx M a Ix Sx M a ln4/ft in3 / ft in -kip / ft In4/ft in3 / ft in -kip ft 26 0.0181 1 0.92 80.0 0.0260 0.0429 1.54 0.0177 0.0366 1.32 24 0.0223 1.13 50.0 0.0344 0.0584 1.75 0.0242 0.0523 1.56 ALLOWABLE UNIFORM LOADS IN POUNDS PER SQUARE FOOT 26GAUGE 24 GAUGE Span In Feet Wind Load Uplift Live Load Stress Live Load Deflection Wind Load Uplift Live Load Stress Live Load Deflection 4.0 101 63 56 115 75 75 5.0 65 40 29 74 48 39 6.0 45 28 17 52 33 22 7.0 34 20 10 38 24 14 8.0 26 15 7 30 18 9 Revlslon Date: August 12, 1998 File: c:\engrform\section properties of panels - u.doc W, �v 'K�N' f, 29-'24-16 774-91E STONE, Bill 50dO Midway.,i,;-Rich4le (elec sery relp ation/sf)' COLIN ' TY OF BUTTE DEPARTMENT OF'PUBLIC WORKS PERMIT NO 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT ASSESSOR PARC5_LA NIEMBER 29-24416 ZONIVG- A40 - BUILDING PERMIT OWNER Bill Stone TELEPHONE 882-4485 SQ. FT. OCC.1 BUILDING VALUATION OVYNER-S MAILING ADDRESS 5030 Midway, Richimle 95974 CONTRACTOR'S NAME Owner TELEPHONE CONTRACTOR'S MAILING ADDRESS FireDlace CONSTRUC—ION LEND ER" UNKNOWN Total Valuation $ Filing Fee $ 110.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR LNZINEER 71 CENSE NO. Plan Checking Fee $ Energy Plan Checking Fee ARCHITECT OR ENGINEER'S MAILING ADDRESS .. . . . "r, Penalty $ BUILDING ADDRESS t6 �, 6 , 1) 1 . , Midway, Richvele Permit fee $ PLUMBING PERMIT Fi ling Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20-00 LOT NO. SUBDIVISION NAME PARCE . L MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF a Duplex Fj MobilehomeF-1 Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W .00 ea� TYPE OF WORK New F� Addition [:1 Remodel[] UtilitiesO InstallationEl Other Describe work: move main power Permit Fee $ Contractor ELECTRICAL PERMIT FilingFee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 10.00 Main service EA. ADD -L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare'under penalty of perjury (check one): 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification V 0 7 yo 0W10sole compen- 1, as the owner, or my molZeL- -Wit W4gett e p 01-11 VIV sation, will do the work, and the structurEf is not intended or offered for sale. (Sec. 7044) El I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) 1 am exempt under Sec.—, Business and Professions Code for this reason NEW CONST DWELLING CCUP.8d) OR DDNS. ACC.BLDGS. 21/20scift NEW CONSTR. MULTI -OUTLET NON-RESID. BRANCH CIRCUITS) 2.50 eal (POWER APPARATUS.&) SINGLE OUTLET CIR Ex. Occup(OUTLETS OR FIXTURES 20 0 50t . AL@ 30t OCCUP. FIXED APPLINIS R Ex. OUTL E TS IRESI*D0) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 15.00 pre inspection 15.00 Permit Fee $ 50.00 Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 2"'1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Fi I ing Fee 10.00 Heating Cooling Hood 3.00 1 Ventilation — . . I Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyol Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities . d t , costs, and expenses which may in any way accrue a 60,,utgmpnc s against sai un y _ onsequence of the granting of this permit. X Date –?-..,L 0/ Signature of Applicant — Owner 0 Contractor El AgentEl An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE 50.00 TOTAL FEE $ HAZ I CUA I PARK I SCHL I ILE71 I PAR 1. HD. Iss V Th's permit is hereby issued unaer the applicable provi- sions oi the Butte County. Code and/or resolutions to do work indicated above for which fees have been paid. DIRECT F UC WORKS j9 0 PUig I By(Ilp DatA. ?h h 121- PERMIT EXPIRES Date �6 I'/ Q A Receipt No. 93720 WHITE-O.P.W.. YELLOW-ASSE350R. PINK -INSPECTOR. GOLD ENROD-APPL I CANT .COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT WERM I \TN �?—,7,V- k�/_ ASSESSOR PARCEL NUMBER 29-24-16 Z C' 0 A40 BUILDING PERMIT OWNER Bill Stone TELEPHONE 882-4485 SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 5030 Midway, Richviale 95974 CONTRACTOR'S NAME Owner TELEPHONE CONTRACTOR'S MAILING ADDRESS I FireDlace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR E.'J.-,INEFP T—Cff"NSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 5030 Midway, Richvale Permit fee $ PLUMBING PERMIT FilingFee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. UBDIVISION NAME 1 PARCEL MAP 1 Water piping 5.00 Each qas w ater heater or vent 5.00 1 USE OF STRUCTURE SF a Duplex F� Mobilehomef-I Other SPECI FY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I IN 10-00ea TYPE OF WORK NewF_1 Addition[] Remodel[J Utilities 0. InstallationEl OtherE] Describe work: move main power Permit Fee $ Contractor ELECTRICAL PERMIT FilingFee 10.00 main service 600V OR LESS 100 AMP OR LESS 10.00 10.00 Main service EA. ADD -L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): F-1 I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. 2r,"l, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) I am exempt under Sec.—, Business and Professions Code for this reason NEW CONST DWELLING OCCUP.N) OR ADDNS. ACC.BLOGS. 21/2 Osq I t NEW CONSTR. MULTI -OUTLET NON-RESID, BRANCH CIRCUITS) — 2.50 ea (POWER APPARATUS &) SINGLEOUTLET CIR. Ex. OCCUP(OUTLETS OR FIXTURE 20@50c ALO 30C FIXED APPLNS. 0 R Ex. Occup. OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 15.00 pre inspection 15.00 Permit Fee $ 50.00 Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): n The permit is for $100.00 (valuation) or less. E:] I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate I Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shal I be deemed.revoked. MECHANICAL PERMIT Fi I ing Fee 10.00 Heating Cooling Hood 3,00 Venti lation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against s�)q County In,consequence of the granting of this permit. �AftvF --- Date-? -a-2e-el_ Signature of Applicant - Owner F!!fr Contractor El Agent El An OSHA permit is required for excavations over 5'0" deep and demolition or construct. ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee occ EHAZ. C NST TYPE TOTAL FEE $ 50.00 I CUA I PARK I SCHL I FLD I CDF I PAR JPD JJHD,JISS 7 This permit is hereby issued unaer tne applicable provi- si�ns oi the Butte County. Code and/or resolutions to do work indicated above for which I s have been paid. DIV OF P WORKS If -44 914 Date Bya� PERMIT EXPIRES Date 149-a- Receipt No. C� 0 WHITE-O.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDEN ROD-APPL I CANT COUNTY OF BUTTE - DEPAATMEN OF PUBLIC WORKS - BUILDING DIVISION '�Rbv% 7 COUNTY CENTER DRIVE - 0 IL .,,E, CALIFORNIA 95965 - TELEPHONE: 916/538-7541 PERMIT APP819P ION DATA SHEET 0 .. Permit No. OWNER A. P. No., Proposed Building Use Building I nspector Q Date Af time of permit application, I was advised the following data must be submitted prior to permit processing And/or issuance: DATE RECEIVED ' '. APPROVED 1 . All items have been submitted . ..................................... 2. Plot plans in duplicate/triplicate, signed by preparer of plans 3. % Complete plans in duplicate/triplicate, signed by preparer. of plans 4. Complete engineered plans and calcs, with wet signature on plans 5. Hazdrdous Material Form ........ 6. Energy Design Compliance and supporting documentation ......... 7. Statement of Intent for Non -Heated and AC Buildings .............. 8. Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation instructions........................................................ 10. Fees of $ ........................ 11. Chico Urban Area fees paid ........................................ 12. Park fees paid ..................................................... 13. School District fees paid .............. 14. Sanitation approval from Health Department 15. City of Chico plumbing permit ..................................... 16. Plot plan and business license approval from,City of (see C`1 y for other requirements) 17. Planning approval for (A) Use:—(B) Parking: . ...... 18. Improvements may be required. Contact Land Development Section DPW 19. Driveway permit (construction approval required prior to occupancy) EteCAK,CA Pre-Inspec. request t Aog� 20. Pre -Inspection for required ... Building Inspector 21. Contractor's license. information, (No., Name Style, Classification) —22. Certificate of Workmar.)g Compensation Insurance .................. 23. Owner -Build er Verification (Given to owner 0, Mail to owner 0) —24. Recorded copy of Agricultural Acknowledgment Statement ......... —25. Letter of signature authorization .................................... 26. 27. When you issue the permit, procbss as follows: Mail to owner. —Mail to contractor. Telephone and hold for pickup at —office. —Deliver w/inspector. Other Applicant Date 3-az4/1 Copy of Haz-Mat iorm sent —Health Dept. —Fire Dept. ---Air Pollution Date Copyofplanssent ___HealthDept. _____FireDept- —Other— Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by—phone--Mail—cdunter by ..date Contractor, designer, owner, was advised of above required data by—phone—mall—counter by— date Plans checked by Date Plans approved by Date —Sets of plans on hold in —File cabinet _AP folder Copy—DPW TYPE OF WO - RK I I New C] Addition [] Remode,E] utiiitie Installation[] Other Describe work: 1144t�l edweie fin, CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) I am exempt under Sec.-, Business and Professions Code for this reason WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): F� The permit is for $100.00 (valuation) or less. C] I have placed on file with the County of Butte Building Department a Cemificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. I shall not employ any person in any manner so as to become subjecl to the W. C. laws of California. Notice to Applicant: if after making this statement, should you become sub ec to the W. C. provisions of the Labor Code, you must forthwith comply with suct provisions or this permit shall be deemed revoked. I S W I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County ot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnity and keep harmless the County of Butte against all liabilities, judgments. costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date - Signature of Applicant — Owner 0 Contractor f Agent M An OSHA permit is rTuirad for excavations over 5*0" deep and demolition or construct- ion of structures over stories in height. Contractor COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916/538-7541 APPLICATION AND PERMIT PERMIT NO. .SSESSOR PARCEI-'NUMB.R 1(0 N -1/ () I - BUILDING PERMIT 10 .00 )WNER a i ( I S TO t13 e_ ain service F -A. ADO -L 100 AMP TR(;rjf*y 6_5 SO. FT. OCC. BUILDING VALUATION NEW CONST. DWELLING OC CUP*ai) OR ADONS * ( ACC. SLOGS. 2'/2Csqft )WNER'S MAILING ADDRESS C-AIST741 2.50 ea (POWER APPARATUS &I SINGLE OUTLET CIR. :ONT,JACTQR* A M I- �J ko �aT ONE 0 .2AL0,95300eq FIXED AP LNS. OR Ex. Occup. 0 UTLETSP(RE SIC.) E A.) 2.00 -ONTRACTOR'5 M^I%_tNG ADORES3 Fireplace Mobile Home Facilities CONSTRUCTION LENDER UNKNOWN Total Valuation is /5,00 -Misc. p gE— �gA,5 p Jo-KeW Filing Fee S '0.00 LENDER'S MAILING ADDRESS $ Per -ii! Fee $ ARCHITFCT OR MECHANICAL PERMIT ICENSE PJO. Plan Che-::1-ing Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING AOCRESS Penalty $ SUILDING AOCIRES3ijUJA�:e 9C �c�LJA( _t4 39 1 Permit fee $ PLUMBING PERMIT FilingFee 10.00 Each Trap 2.00 Permit Fee $ Solar or heat pump water heater 20-00 LOT NO. SUBOI VISION NAME PARCEL MAP 1 Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE S F),(, OuplexF� MobilehomeF Other SPECIFY as piping . system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Ho - me S I G I W 10.00 ea TYPE OF WO - RK I I New C] Addition [] Remode,E] utiiitie Installation[] Other Describe work: 1144t�l edweie fin, CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) I am exempt under Sec.-, Business and Professions Code for this reason WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): F� The permit is for $100.00 (valuation) or less. C] I have placed on file with the County of Butte Building Department a Cemificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. I shall not employ any person in any manner so as to become subjecl to the W. C. laws of California. Notice to Applicant: if after making this statement, should you become sub ec to the W. C. provisions of the Labor Code, you must forthwith comply with suct provisions or this permit shall be deemed revoked. I S W I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County ot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnity and keep harmless the County of Butte against all liabilities, judgments. costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date - Signature of Applicant — Owner 0 Contractor f Agent M An OSHA permit is rTuirad for excavations over 5*0" deep and demolition or construct- ion of structures over stories in height. Contractor ELECTRICAL PERMIT JFilingFeel 10.00 600V OR LF -55 main service 100 AMP OR LESS 10 .00 ain service F -A. ADO -L 100 AMP 2.50 NEW CONST. DWELLING OC CUP*ai) OR ADONS * ( ACC. SLOGS. 2'/2Csqft LF —NEW CONSTRE -WULTI_.UT _T .0..RES... BRANCH CIRCUITS) 2.50 ea (POWER APPARATUS &I SINGLE OUTLET CIR. Ex. OCCUP(OUTLETS OR FIXTURES 0 .2AL0,95300eq FIXED AP LNS. OR Ex. Occup. 0 UTLETSP(RE SIC.) E A.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 . Wiring 15.00 /5,00 -Misc. p gE— �gA,5 p Jo-KeW /5-00 Permit Fee $ Contractor MECHANICAL PERMIT FilingFee 1 10-00 )00 Heating Cooling Hood 3.00 Ventilation 7 Permit Fee $ ---Contractor Mobile Home Installation Fee $ Rarpint Nn W"ITX-O.P.W.. YELLOW-ASSf330R, Pimg-INSPECTOR. GOLDENROD-APPLI CANT tnergy inspection t-ee OCC I CONST TYPE I HAZ TOTAL FEE $ SCHL i FLO I COF '451 50.00 PAR i PO li HO.TIS—SUE Th:s permit is hereby issued unaer tne applicable provi- sions or the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date COUNTY OF BUTTE - Departw-Ont of Public Works 7 County Center Drive,'Oroville, CA 95965 Phone: 916-538-7541 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. 1 personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) 2. 1 (have/have not) haile, signed an application for a building permit for the proposed work. 3. 1 have contracted with the following person (.firm) to provide the proposed construction: Name Address City Phone Contractors License No. 4. 1 plan to provide portions of this work', but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractors License No. 5. 1 will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address . Phone Type of Work Signed: Property Owner Social Securit N mber Date ?-.201/ NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are per- mitted to issue the permit. PRE -INSPECTION OWNER: LOCATION: Soz 'o A. P. #-29 -Z(l k I ZONING_/-I-�/O DATE 3 -2 0-'// CONTRACTOR: PRE -INSPECTION FOR: 671ec lie, ?-.f / S-eeoce- I—.- h6me OUO)et /,A,4 /�V -tb eole- DATE TO INSPECTOR PERMIT H ISTORY: NONE Q�r AS FOLLOWS: A 6- ����z Anezy_l TYPE OF OCCUPANCY 0 US -0-0 F FIELD - INFORMATION BUILDING USAGE: TENNANT: Ea --a cCUPIED E�r HAS ELECTRIC ���_S__6AS SANITATION FACILITIES E]-HfATED-COOLED PERSON CONTACTED OTHER COMMENTS: ACTION R OMMENDED: ISSUE E::] HOLD FOR E= OTHER: 11-M DATE 3- 2- "" - COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 9�965 - Telephone 916/534-4541 AGRICULTURAL BUILDING EXEMPTION PERMIT PERMIT NO 4 �(!::' — Agricultural building is defined as follows: Agricultural building is a structure designed and constructed to house farm implements, hay, grain, poultry, livestock, or other horticulutral products. This structure shall not be a place of human habitation or a place of employment where agricultural products are processed, treated, or packaged, nor shall it be a place used by the public. ASSESSPR PARCEL NO. 1,7 9- o2 - ZONING I-ILI) -JV OWNER Stan& P'O 0 1. —A), OW)9R'S &PDRESS/I /99, Z� , . ( ') I CIA W -an 'X LOCATION OF BUILD V ir-� Vale USE OF BY-JLDING S fiO �D VA I yy VLA4 .0 SIZE OF STRUCTURE V X 9 SO. FT. /fl r.V TYPE OF CONSTRUCTION: WOODFRAME—STEEL CONCRETE— OTHER (Specify) TYPEOFSIDING ROOF COVER�", FLOOrYPE _ ESTIMATED COST OF CONSTRUCTION $ AG Buildings shall comply with the building front, side, and rear yard requirements of the applicable County Ordinances as follows - FRONT REAR AG Buildings shall be a minimum of five (5) feet from any septic tank or leach fields. AG Buildings less than 1000 sq. ft. in floor area shall be located a minimum of 6 feet from a residence, 10 feet from a mobilehome, and 23 feet from a commercial building. AG Buildings greaterthan 1000 sq. ft. in floorareashall be located a minimum of 23 feet from a residence and a mobilehome, and 40 feet from a commercial building. I declare under penalty of perjury that the building will be used as stated above and the proposed use conforms with the AG Building definition. If any change in use or occupancy of the building is made, I will contact the Department of Public Works and will obtain any necessary permits, inspections, and approvals to comply with the requirements in effect at that time and before occupancy. A" Date 111J0 Signature of Owner Permit Fee - $25.00 The above described AG Building is exempt from a building permit. Receipt No. Director of Public Works By Date White - DPW, Yellow - Assessor, Pink - B. L, Goldenrod - Applirant COUNTY OF BUTTE DEPARTMENT FoPU.,.BLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFOR'NIA 95965 - TELEPHONE: 916/534-4541 PERMIT APPUCA. 'N"DATA SHEET Permit No. OWNER P. N o, AO Inspe, Proposed Building Use ctor_2�� Date At time of pplication, I was advised the following data must be submitted prior to permit processing ,ermit a =andJor 1 fj DATE RECEIVED APPROVED 1 . All items have been submitted. . . . . . . . . . . 2. P,Iot plans I I n duplicate./triplicate, signed by preparer of plans. 3. Complete p! ans in duplicate./triplicate, signed by preparer of plans. 4. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. 6. CUSD ''Fees Paid'' Stamp on Floor Plan . . . . . . . . 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ . . . . . . . . . 9. Letter of signature authorization . . . . . . . . . . . 10. Sanitation approval from Health Dept. . . 11. PlAnning approval for (A) Use:—(B) Parking:— . 12. Certificate of Workmen's Compensation Insurance . . . . . . 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to ownerEl, Mai I to ownerE] —15. Improvements may be required . . . . . . . . . . . . 16. Mobilehome Installation Data. . . . . . . . . . . . Pre-Inspec. request to (Date) 17. Pre -Inspection for Required- Building in s pector 18. Recorded copy of Agricultural Acknowledgment Statement. 19. Driveway Permit. —20. Plot plan approval from city of —.21. —22. When you issue the permit, process as follows: _7N ail to owner, —Mail to contractor. —Telephone and hold for pickup at—off ice, —Deliver w/inspector. Other Applicant Date 47 Copy of plans sent — Health Dept., —Fire Dept., — Other Date The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by—phone---mal I —counter by— date Contractor, designer, owner, was advised of above required d ta by —phone —ma I I —counter by— date Plans checked by Date lans approved by Date Sets of plans on hold in Copy—DPW File cabinet AP folder — Flours: 10:00 a.m. - 3:00 p.m.