Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
030-102-024
% 030-102-024 PERMIT#97-0592 BAKER, William 1425 Tehama Ave., Oroville I., qV Cont: Baker Construction New Single Family M THERMALITO IRRIGATION DISTRICT 410 GRAND AVENUE OROVILLE, CALIFORNIA 95965 TELEPHONE: (916) 533-0740 FAX: (916) 533-9243 P3° r,3 10 SEWER SERVICE APPLICATION AND CONNECTION PERMIT Service Address: 1425 - 16-t::: it Av�►iiuc Owner's Name: Date: 4/14/97 Address: 22-�l St, Crnr-,n i nnst Acct. No.: 0��069 ala (" tirn. C1. A.P. No.: Phone: 393"97°u New Unit: 1 'Wj-:=C Applicant/Agent: Adding Units: Address: Fees: Phone: Permit: $=� T.I.D.: Preliminary Review By: Date: Ext. Fees: ' Remarks: r -Or =tio.-I f:—= will lx: uloc ! Z1,3nl Cable It tirm of SC -OR: �(i.7 �r cora motion to t= sc-w= collector. rvz;tci. Clr-,ia out ren to Lateral: 75 1. e;rwdc rLquircd at Vroprrty lino. Other: Total Fees: Amount Paid.OF 1�5•Ca Collected By: S. +•nr Finaled By: Date:,TGr/� r1 Location: /`�`a.5 T��i� �i,u 44 v Size Line: f- Lit f, ey Signature of Owner/Agent:,.' r MONTHLY SERVICE CHARGES WILL COMMENCE AUTOMATICALLY UPON COMPLETION Date Billed: Computer: Paid SC -OR: A.P. File: (R.F.C.) Blue Book: Paid SC -OR: Meter Book: (S/C HG's) Rev. 5/95 RESIDENTIAL f.n 1) A PERMIT#97-0592 BAKER, William ille 1425 Tehama Ave., Orov Cont: Baker Construction �New Single Family OFFICE COPY Of ell 5 4 SIMI!) ldr, dam,-i:��,��,��.�'�` OFFICE COPY J Address GAS Meter By Date ELECTRIC Meter By E�4DaCt?��—— JO0 FINALED (Date) Signature Address GAS Meter By Meter By Of ell 5 4 SIMI!) ldr, dam,-i:��,��,��.�'�` OFFICE COPY J Address GAS Meter By Date ELECTRIC Meter By E�4DaCt?��—— JO0 FINALED (Date) Signature V=OK O = Not -OK. :=INotRel*ble MOBILE HOMES ` Date MOBILE HOME UTILITIES (Plans) OK except #'s DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements - Setbacks - Easements 1. Zoning Requirements -Setbacks -Easements 2. Soils; Spectral MH Support Sketch } 2. Footings; SoilsSize-DepthSpacing-ConnectorsSteel 3. Sewer; Location -Test -Fall -C/O -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water, Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors - Shthg: Rfg: Bracing 5. Electricity; Location-Clearances-Gmd-/ /Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap; / /'9_'ft. / /Nat. or/ /'L"ft./ /LPG 6. Carports; Windows -Doors 7. Well Clearance & Disconnect 7. Electric 8., Utility Clearance 8. Fnng.;Sils-AnchorsStuds-Rftrs-Trusses �.. 9. Siding; Nailing VeneerStuc oo-Mesh Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s'•. 1. Zoning Requirements- Setbacks Easements t Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line Card B-1 Date Card B-1 3. Gas; MH Test -Demand -Valve -Connector POOLS (Plans) OK except #'s 4. Electricity; MH Test -Crossovers -Breakers -Clearances 1. Setbacks -Easements 5. Drain; MH Test -Fall -Flex Connector 1 2. Soils; Compaction -Structure Stability 6. Water; MH Test -Regulator -Connector 3. Pool Structure; Steel -Connections -Thickness , Dead Men -Lining 7. Water and Sewer Connected -C/O to Grade -HD Approval 4. Elec.; Receptacles and Lighting, Distance-GFI 8. Gas and Electricity Tagged ' 5. Elec.; Pool Lighting; 15 Volts-GFI 9. Tie Downs -Type -Installation Cert. 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 10. Exits; Insp.-Sketch 7. Elec.; Bonding; Metal w/6 -Circulating Equip. -Heater 11. Cert of Occupancy 8. Elec.; Grounding; Equip. w/5 Circulating Equip. -Pool LBhtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval Date Card B-1 Date Card B-1 Date Card B-1 Date -Card B-1 t I Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date- DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; SoilsSize-DepthSpacing-ConnectorsSteel f 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors - Shthg: Rfg: Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures i Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date- DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; SoilsSize-DepthSpacing-ConnectorsSteel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors - Shthg: Rfg: Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Fnng.;Sils-AnchorsStuds-Rftrs-Trusses �.. 9. Siding; Nailing VeneerStuc oo-Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness , Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/6 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5 Circulating Equip. -Pool LBhtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓ = OK O = NotO = Not Alicatile = Not Ready ' except RESIDENTIAL (Single & Duplex) (�Ftg., Main; Soils-Elec. Gmd.-//ZJJ Ftg. Depth t GRrGarage; Soils-Steel-Elec. Grnd/ / 2J' Ftg. Depth 4. Ftg. Porches & Decks; Soils -Steel-/ J' Ftg. Depth emwalls, Main; Steel-Blockouts-Wrapped e IIs, Garage; Steel-Blockouts-Wrapped 6A -461d Downs and Special Anchors 7. Slab, Steel -Wrapped 8. s -Fireplace Ftg.- tee) V.; Fi ' -T ayC/O ewer Test 10. UF. Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 16. Insulation Date 9 Cqrd B-1 Date Card B-1 Dated- /9-9-7 and B-1 Date Card E-1 Date ' PLUMBING (Permit) OK ex pt #'s - ater Htr.; Vent-Acces -C stion Baffle cj / U Water Pipe; Test & Anchor -Nail Protection D.W.V.; Test Fittings & Anchor -Nail Protection Shower Pan; Test, First Floor -Tub Access 1 Test Tub & Shower, Second Floor -Tub Access Gas Pipe; Sixe & Anchors Date/1 I Card B-1 Date Card B-1 Date/J Cj_p,c�-7 Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Fkture & Transformer Clearance -Ins. Protection lec. Receptacles Spacing -Lights & Switches at Doors Size Boxes & No. of Conductors Stapled mex Installed Close to Edge of Studs & C.J. quip. Ground made up w/Mech Fastners-Bond Gas & Water 2 Appliance Circuts in Kitchen & Conductor Size GFI — eg-Subfeed Wire 'z / ga. Cu or AI-A.C. Wire Size1/ / ga Cu or Al 30. Range Circ. / / ga AI -Oven Circ. / / ga Cu or All jritulated Neutral es p No rvice-Riser Conductors & Ground -Main Disconect ip. Clearances Panels-Motors-Mech. Epuip. S1lothes Closet Light -Shower Light -Spa Light Smoke Detector Date n1YX VIM itard B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Ducts Insulation & Support S Vent F n, Exhaust above insulation ndensate Drain & Overflow, Size & Grade 9.1 Furnance-Vent Access -Comb. Air -Return Air Vent 115 outlet '39. Attic Access & Platform if Furnace in Attic Date k/ j and B-1 i pate Card B-1 Date Card B-1 Date Card B-1 Dat FRAMING (Plans) OK except #'s Sits Proper Materials & Anchors IIs Studs -Nailing Spacing & Braces -Plates -Sound Bearing Walls over Girders & Floor Nailing Draft Stop in Walls (rat proof) P(re Stops, Furred Ceilings -Stairs -Chasers -Tubs Headers & Beams -Size & Bearing Date FRAMING (Continued) /D ling. Joist-Rfr.. Ties-Purlin-roff Brac.-Truss-Shting.-Ring. /Fireplace Ties or Type ue-Fireplace Throat clearance Attic Access; Size & Ro ex Protection -Draft Stop -Ins. Baffles V6.4drm. Windows or Exiting rs-Sill Hgt. & Dimensions .Garage Fire Protection Framin Property Line Firewall & Openings 53. Ext. Doors-One_3-Check Garaqe 3rd Sim. 2 Exits Vents -Rafter .(37. Xtuccg Mesh-0tip Screed -Fd. Vents-Underflr. Access 62. Panels Date jf3(0(' IL/ Card B 1 §� Date -� ��Card B-1 Date /O_q 7Card B-1 Date T— Card B-1 Dat INAL (Plans) OK except #'s xteps-Door & Sidelight Protection -Landings t 4oOSmo Detector 5. rnace; Vents -Clearance -Comb, Air-Conector- In ge; Ap6ve Floor-Ducts-Mech. Protection dro xiting ath res & Tub A ss -Spa Elec. Trim & Subpanel, Breaker Sizes & Labels W E uflets at Wood Panel, Int. & Ext. 710!Ki ixt. & Appliance; Ground. -Air Gap-Cookjg Clearance 7 . lec. Outlets & Receoticales at Kit. Coun M 6o.C. Duct in Garage -Damper tr. Htr.; Vents -Clearance -Com it C ector-P. . . In e; Above Floor-Mech. Protection Ib., Elec. & Mech. Equip. Listed for Location ec._Paceptacles in Garage G.F.I. -Romex Protection Pr nsul i n -Foam -Looked in Attic dn. VBents & Crawl Hole Door Drainage & Wood-Earth"4 Clearance Looked undacFloor n Yes No/1Nalks 0 Yes 0 No/Planters p Yes p No nit Disconnect, Electrical -Plumbing en Above Roof, PIbg-Appliance-Fireplace-Clearance to Openings Well, Disconnect, Electrical, Plumbing for Elec. Trim, G.F.I. Receptacle -Underground Veplation Throught House Er & Sewer Connected -C/O to Grade -HD Approval aV Energy Compliance Certificate -Other Certificates Date Card B-1 jM Date Card B-1 Date a, -5j _ZG T Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE BUILDING DIVISION I' i j DEPARTMENT OF DEVELOPMENT SERVICES 41 i Main Street, Chico, CA - (916)991-2'751 7 County Center Drive, Oroville, CA - (916) 536-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact4his office immediately. /I// ffo-1w?s--/, 4.' di+e-& e� aGZ.•��4 iV . L_' y it Date REV 1 Inspector T COUNTY OF BUTTE BUILDING DIVISION • DEPARTMENT OF DEVELOPMENT SERVICES _411 Main Street, Chico, CA - (�1'6) 891_-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 r CORRECTION NOTICE OWNER `PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. Ifyou have any questions pertaining to this matter, or need additional explanation, please contagf this office immediately. 04, a ,j, e -a 'Z C 421 S =4= 12-212 r r Date 7 9- Inspector ICA 5S r a, REV 10/ 2 F _ _ _'-�,oi. .. _..:.y .�. �,:�.,,'7ntai7�uv.T`_`y"y."""'-r"�"v`+i.•"T^"�-rriliw[7's-:":e�,+.'„"y� COUNTY OF BUTTE t' BUILDING DIVISION •�,• DEPARTMENT OF DEVELOPMENT SERVICES .411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE OWNER -- 5 � Z -- PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining:to this matter, or need additional explanation, please contact this office immediately: A I - _ Date 9 "� Inspector I REV 10/9 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE ER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. -f �`i—c5IL 7-7 Date _ Inspector REV 10/92 ' COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - ('316) 851..-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE Q-7 OWNER - /' PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, pleasencontact this office immediately. Date 7je--/"J / Inspector REV 10/92 v _ � -� ,.fie ti.t.;; ,....S.y r�.r'sl�,�-kd'.--^"'�.u�'1.^-=�-.�'"'rs.:•"'^r`+'�."�: :r-+...�-�.��.+�.--fi-YTr+•`ti--f COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE OWN—ER"— —PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need addi onal explanation, please contact this office immediately. Date Inspector — REV 1Q(92/ COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT. SERVICES 146'9 Humboldt Road, Chico, CA - (016) 89'1,=2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 i CORRECTION NOTICE ER PER r;z A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. r '+S L` 3 .y Date /�� (nspector��� R REV 10/92 - COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA.- (916).891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE 97-:5 OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. Date REV 10192 Inspector d i✓ • COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE &40cc '`'7-5q7, OWNER . PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, �Pa contact this office immediately. /1 Date Q ! 9-7 REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (9.16) 891•-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE ER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. Date / Y1_ Inspector REV 10192 �` COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (9160 891-2751 7*County Center Drive, Oroville„ CA - (9161 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE PEF A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address a should be corrected. Please notify this office when correction of work is completed If have any questions pertaining to this matter, or need additional explanation, please c this office immediately. —f Date n REV 442 Date n REV 442 NINE COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA , (916) 891-2751 7 County Center Drive, Oroville, CA -- (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWN PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. A. z' c2 ti 41c:' Pau o r. Date Inspector REV 10/92 COUNTY OF BUTTE ?� BUILDING DIVISION ` DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891,2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 �G� CORRECTION NOTICE e�/t1Lt_ OWNER PERMIT NO A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you haye-any questions pertaining to this matter, or need additional explanation, please contact th' office immediately. loo GREGORY A. PEITZ ARCHITECT 1907 MANGROVE AVENUE, SUITE "E". CHICO, CA 95926. (916) 894-5719 Gly q <t 711 Ac) �� Se CY A C -l' 147 ,j --p 1-7 n� o a I -L. CAd 1- s 4ve c{ � Lie—/ AR co ONO. c H283 � REN: CERTIFICATION OF INSULATION ADDRESS OR TRACT SACRAMENTO INSULATION CONTRACTORS LOT M ❑ P.O. BOX 854, WEST SACRAMENTO, CA 95691 LIC. #202026 1453 GARDEN HWY., YUBA CITY, CA 95991 LIC. #202026 0 P.O. BOX 9651, FRESNO, CA 93793-9651 LIC. #202026 ❑ P.O. BOX 1631, RENO, NV 89505 LIC. #10675 _ �n� ❑ 3326 A PONDEROSA WAY, LAS VEGAS, NV 89118 LIC. #10675 DATE, I�SULFj,TfOMPLETED ( SQUARE FEET) ( SQUARE FEET) ( SQUARE FEET) TYPE OF INSULATION TYPE OF INSULATION TYPE OF INSULATION MATERIAL MATERIAL MATERIAL FIBERGLASS FIBERGLASS FIBERGLASS FORM FORM FORM BATTS BATTS & BLOW BATTS MANUFACTURER'S PRODUCT I.D. MANUFACTURER'S PRODUCT 1.0 MANUFACTURER'S PRODUCT I.D. MANUFACTURER - MANUFACTURER MANUFACTURER OCF OCF OCF BAGS R - VALUE APPLIED R - VALUE APPLIED MIN. INSTALLED R - VALUE APPLIED INSTALLED THICKNESS INSTALLED THICKNESS WEIGHT PER SQUARE FOOT INSTALLED THICKNESS KNEE WALLS IF R -VALUE IS OTHER THAN WALLS ABOVE MATERIAL FORM R VALUE MANUFACTURER FIBERGLASS BATTS OCF AIR INFILTRATION SEALANT MATERIAL MANUFACTURER W R GRACE THIS IS TO CERTIFY THAT INSULATION AND/OR SEALANT HAS BEEN INSTALLED IN CONFORMANCE WITH APPLICABLE CODES, MATER TANDARDS AND REGULAT NS. • SI N URE— ON CONTR TITLE DATE MANAGER � SIG - NERAL CO R TITLE DATE REMARKS' { 11 s } f .. I SIC -303 BUILDER COPY THERMALITO IRRIGATION DISTRICT 410 GRAND AVENUE OROVILLE, CALIFORNIA 95965 TELEPHONE: (916) 533-0740 FAX: (916) 533-9243 c? N° 2019 SEWER SERVICE APPLICATION AND CONNECTION PERMIT Service Address: 1425 - Tehama Avenue Owner's Name: William Baker tDate: 4/14/97 Address: 2231 St. George Lane Acct. No.: Chinn, CA- 95926 P. No.: 30-102-024 Phone- 893-9790 N Unit: 1 house Applicant/Agent: Addin Units: Address: Fees: Phone: Permit: $30 DO 600 00 Preliminary Review By: Date: Ext. Fees: ' Remarks: -Connection fees will be those applicable at time of SC -OR: 900 50 connection to the sewer collector system. Cle�.jn out up to Lateral: 79 M— grade required at property line. Other: Total Fees: 1605 0 Amount Paid: 1605.00 Collected By: S . Fox Fnaled By: _= t`�' yk Date: � Location: Size Line: 40" Signature of Owner/Agent: Qya MONTHLY SERVICE CHARGES WILL COMME14CE AUTOMATICALLY UPON COMPLETION Date Billed: Computer: Paid SC-OR: A.P. File: (R.F.C.) Blue Book: Paid SC -OR: Meter Book: (S/C HG's) Rev. 6M6 03%23.97 09:01 $916 244 3329- MUSS LMBR TRUSS Z001 -=ccc<ACES-32 Ver. 2,:91563 I==s,=_=-^==««MOSS�0~02 25 1997 Customer BAKER Wed Aug RH-240 3 Family # �h project #: 1 -�0 Tniss 1T; AGE Top itch 6 12 Span 7 _Quantity NOTES : Ili -Gable stud$ spaced At Is inch s o.C.+Ww -Brace vertical studs in accorclarice With standard able end detail 3-ContinuouF bearing pravited along ea�leestudtunlessrd. othcrwise noted 4) -Provide lh4 plates at cath end I)z g 10-4--3 1S-7-13 10 ` 5-2-1 5'2-1 5-3-14 2-2-3 5X6 Sx6 TOP CHORD FROM J1._Z_T0 JT.� TO ne SHEATRED Lx(u+CED ATarL+__IN, o.(;. MAX. NOTE: --AA Mate CICS b Worllma +P Accordance with Recognized Goppad Prflctices U a Unility form Building, Plumbingr& Mechan+cal ufc Urnfor the Nab+onol Electrical Coda, re Il'1 vc6 L. HL TO pR:11-6-13 k ' R HL TO PK ;2-5-4 LEFT HEICTIY'I'; 0-4-3 SPAN:17-10 RIMS -10-3 RIGHT HEIGTjT:4-5-3 PS ----- MINIMUM GRADE OF LUMBER LOADING ( (PST') R MAX - $"!'FtESSES TOP C140PD: 2X4 Ncn, 1&Btr GR DF -L TOP G0 D ': BOT CHORD:2X4 NO.15,Etr GR DF -L BOTT 0 7 LL,DEFL.90-aO 00 c Lj:s60 WEBS ----_2X4, _5TANDART1_G12_DF`_L_r== TR r. INC_: LUMB = 1 15 PLATE 1-.15^ -SPACING . 24.0 in e- C- R.EPETrTIVE STRESSES USED NO. OF MBMBERS = 1 DEFLECTIONCIN.) L.L= 4,OO,b.L=O.00,t.L=0.40 PLATES ARE MITEK M20.166,147 MANUFACTURED FR0A ASTM A 446 QRD A OAI.'ANIZEb STEELMCCPT A+ SHOWN) PLATE MUST BE INSTALLED ON EA. FACE OF JCINT,STMMETRIGALLY(EXCEPT A;; SHOUM)DESIGN CONFORMS u/NOS DESIGN SPECS, UBC-ICRO,IPI�91 THIS DESIGN 1& FOR TRUSS FABRICATION ONLY.FOR PERMANENT AND TEMPORA°y SRACINO(WHICH 15 ALWAYS REQD)CONSULT SLOG ARCHITECT OR ENGINEV ��=OtbtvO 97 -as h Ak set of plans and specifications MUST to BUTTE COUNTT 0 on the job at all times and it is unlawful tR3UILDING DEPARTMENT Oke any changes or alterations on same without it -fen permission from the Department -of Pu6 APPROV61) Works, County of Butts,, P %7 AUG 27 1997 01 - COUNTY OF BUTTE -, BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 ,A CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. G c- f 41 ,✓ Date lj Inspector CL"!5 5 REV 10/92 COUNTY OF BUTTE- DEPARTMENT 6F DEV'ELOPMENT.SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 196965 - Telephone (916) 538-7541 q7 PEEERMIT NO (Rev.12/96) APPLICATION AND PERMIT ``�� / ASSESSOR PARCEL NUMBER 030-102-024 ZONING R1 BUILDING PERMIT OWNER WILLIAM BAKER TELEPHONE 893-9790 SO, FT, OCC. BUILDING VALUATION 1181 R 63,774.00 OWNER'S MAILING ADDRESS 2911 ST GEORGE T.N 413 - 5 11 7,803.00 CONTRACTOR'S NAME TELEPHONE' in C. 130-00 1 CONTRACTORS MAILING ADDRESS 9931 ST GEORGE LN CONSTRUCTION LENDER FEATHER STATE RIVER BANK Fireplace LENDER'S MAIUNG ADDRESS cliko Total Valuation $71- n7 -nn ARCHITECT OR ENGINEER BOB MRTZGFR LICENSE NO. 386799 Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ 23.00 $ PERMIT FEE $ 890.25 LOT NO. 2 SUBDIVISION'S NAME PARCEL MAP 88-18 PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF J] Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap q 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New EX Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 3 BDRM Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 15-00 Mobile Home S I G I W @20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.00 Main Service zoonoRLEss 23.00 9,1 nn CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. / -701q License Class "j LIC. NO. (�% OWNER -BUILDER DEC RATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. >ir I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason To Main Service TO 200ALICENSED 46.00 NEW CONST. DWELL WEE OCCUCUP. OR ADDNS. ( a Arc. BLDs. SO 3.50x: NON•RESIDT LCI OUTLET1 CIRCUITS POWER APPARATUS 8 SINGLE OUTLET CIR. EX. OCCLI OUTLET OR FIXTURES .0 Q 1.000 BAL Q .0 Ex. Occup. OUTLEEDTSA REFS D.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE _ Qa WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date �-�— _ Signature of Applicant - caner ❑Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating 2 Z 15.00 Cooling Hood 6.50 Ventilation 4.50 9.00 PERMIT FEE $ 59.00 Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ R13 CONST. TYPE VN TOTAL FEE $ 1230.75 HAZ. D. FE FLOOD DF PD HD PBSUP This permit is hereby Issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ONVe the app (cable provisions Resolutions to do work been paid. / / Q �Daate ` - gra ReceiptNo. 209999 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT U�_ V., COUNTY OF BUTTE- DEPARTMENT OF DEVELIJPMENT SERVICES - BUILDING DIVISION 7 CountyCenter Drive Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. (Rev. 12/96) ' APPLICATION AND PERMIT �� 0529 ASSESSOR PARCEL NUMBER ��--�a4, ZONINO BUILDING PERMIT , °""E' VJt�-(„6'�M �sA�P.�l Toa g.�gp SO. FT. OCC. BUILDING VALUATION OWNERSNO ADORESS - CONTRACTOR'S NAME {'� I"-`�`•,/It`— `.� J� � ��� � <li-� � E/�')��i a CONTRACTORS MAKING ADDRESS ✓ L) CONSTRUCTION LENDER LENDER'S MAILING ADDRESS C, i-1\ P Fre IeCe Total Valuation S ARCHITECT OR ENGINEER m �-�� LICENSE NO. 9� Flin Fee $ 20.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Permit Fee $ . S% Plan Checking Fee $ ` BUR.DINGADDRESS ^*� ' Energy Plan Checking Fee $ ��---- $ PERMIT FEE $ / -Z LOT NO, SUBDMSIONS NAME UA Py"/ y _ PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE Sl`,;G� Duplex ❑ Mobil,home ❑ Other SPECIFY Each Trap 7.00 = - Solar or heat um water heater 23.00 Water piping 15.00 / Each gas water heater or vent 15.00 ( r TYPE OF WORK New dition ❑ Rem, el C3 Utilities ❑ Installation ❑ Other ❑ Describe Work: ���� Gas piping system 1 - 5 outlets 15.00 � Buildingsewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 Main Service aoR .E 2o00v0A OR LESSss 23.00 r LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class LIC. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service 200A TO /000A 46.00 NEW CONST. DWELLING OCCUP. OR AODNS. ( a ACc. B.Os. 50 3.52 : NEW CONST. MULTI -OUTLET NON-RESID. BRANCH IRCUITS 7.50 POWER APPARATUS & SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FIXTURES B20 Q 1.000 Ex. Occup. oFlx� R o oR� 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ e S76 1 MECHANICAL PERMIT Fling Fee 20.00 Heating CoolingJ s' Hood 6.50 Ventilation PERMIT FEE $ 5 Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shallCON not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspectio Fee $ r EEHAZ. T. E TOT / FE I D. FEES MP FL CDF Ay Po HD ISSUE This permit is hereby issued under the of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON applicable provisions Resolutions to do work been paid. Date t Receipt No. 1 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDEN ROD•APPLICANT "�,....�,�..�•.;;,✓.,,,,�,,,.r�.:�y'� t•n.14-.^-�- i�r+4si�r�,.r.p}�t,`.. 'k� ..' 'n'p-'iF`ti�L+d'va.�1'lwr��.�v'�^wn.�..v.r.....--..�,.`..ti.....vr-•,,...,-..�,. ' �� COUNTYOF BUTTE - DEPARTMENT OF DEVELOPMEkT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER nA. No. Proposed Building Use 5 _3T36 �- Building Inspector C? Date 3 Z� At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECENED BY 1. All items have been submitted . ........................................ 2. Plot plans, 3/4 sets, signed by preparer of plans. ......................... . 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form . ............................................ 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . 9. Mobileho a an manuf ' urer's nstall tion ins>; uctions, 2 sets. ........... 10. Fees of $ l ---- I �A�?-. G � y 1 ?S .1 11. Impact fees as shown on attached schedule . .............................. - 12. California Department of Forestry plan approval/fees. ....................... . 3. Flood elevation letter (100 year flood) -by California Engineer ................... _ 14. Sanitation and plot plan approval _ 1 � Health Department. � 15. City of Chico plumbing permit . ......................................... 16: Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. 19. Driveway permit (construction approval required prior to occupancy). .%7D ��y.... st 20. Pre -inspection for to Building ins reque required. . . to Building Inspector (Date) 21.. Contractor's license information. (No., Name Style, Classification) : .............. 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner _). .......... . 24. Recorded copy of Agricultural Acknowledgement Statement . .. 25. Letter of signature authorization. . .... . ......... 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access ....................... :.................. 30. Documentation of 50% subdivision. developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 1. Existing violations/expired permits . .................................... ;.- 32. .32. Plan check list . ...................................................... 33. 34. When you issue the permit, process as follows: Mai owner Mail to contractor. Telephone and hold for pickup at t� office. Deliver with inspector. Other Parcel Creation bi _ Acreage Applicant Date Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. , Other Date By The following data must be submitted prior t permit i uanc V ircle ne item not- ec ed above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner,` advised of above required data by _ phone _ mail unter by _ Date Plans checked by Date Plans approved by Date Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works • 4l5 !/ i•.li �U -�t�... %(Q 1 �K �. YO py � J COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 SCHEDULE OF FEES DUE OWNER A.P. # D Io PROPOSED BUILDING USE �� DATE REC # DATE REC 1. BUILDING PERMIT FEES -- Balance Due ................ $_ -- Additional Fees Due ............ $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee ....... $ SCHOOL DISTRICT FEES O%L© 141% L14 (paid at District Office) 3. SHERIFF FEES (paid at Building Division) / Residential ........ ( x $360.00 = $ 3�d Units Commercial (sq. ft.)... x $0.03 $ Sq.Ft. AN AREA FEES (paid at Building Division) Residential (per unit) . -"I x $ 60 #Units Amt. Commercial (sq.ft.) .. x =$ Sq. Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES Bui $4�5-66(paid at lding Division) 510. 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT 1/ �P��J DATE Original -Owner Copy -Building Div. (Red. 12/96) M, t 6 e .t9 BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) _ ,School District. ?76Ll l L L Building Department No. aso-- - A.P. Numbe 100 - Jurisdiction: � City � County Property Owner Property Location/Address Am 4 Subdivision Lot No. Residential Development Sq. Footage 1 No of -Living Mobile Home Addition (Group R) Units Installation Commercial/Industrial Building Department Representative New Addition (Floor Plans reviewed by School District Personnel) Sq. Footage lincwaing extenor . Roofed Areas) Date ldentificatio o. 970124 yd' * t.k)v *LLSchool District certifies t t-, • J (Applicant) (Street A Fess (Phone Number) (City) (State) _ (Zip Code) has complied w' the requirements of Resolution No. 7 (� by payment of $ representing US/ square feet. B 2926 ULL MITIGATION S School District Representative Date Paid by Check # Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xis (2/97)dmm •.. And when recorded mail to:.. Building Division #7 County Center Drive Oroville, Ca. 95965 BUTTE COUNTY SERIAL NO. - - 1.3 RECORDEOff I War MID 11ALtiEV1M4 0 DATE A60011�APR 14 1997 "m 9-,-roMerr - AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including;= but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: PARCEL TWO THE OFFICE CALIFORNIA, 18. Date: 4/10/97 AS SHOWN ON THAT CERTAIN PARCEL MAP, RECORDED IN OF THE - RECORDER OF THE COUNTY OF BUTTE, STATE OF ON APRIL 21, 1982 IN BOOK 88 OF MAPS, AT PAGE PROPERTY OWNERS: State of California ) County of Butte ) On 4/10/97 before me, LUCY A. PERSHALL personally appeared WILLIAM E. BAKER personally known to we (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my hand and official seal.0 ;aa.. • LUCy A. PAf°Shall o Comm. #1092344 (51 NOTARY PUBLIC -CALIFORNIA BUTTE COUNTY A Signa aSeal: FOPN Comm. Exp. March 24, 2000 C�P�ERSH�ALL A D a 030-102-nPA-nnn THERMALITO IRRIGATION DISTRICT 410 GRAND AVENUE OROVILLE, CALIFORNIA 95965 TELEPHONE: (916) 533-0740 FAX: (916) 533-9243 Pd . 20 .9 SEWER SERVICE APPLICATION AND CONNECTION PERMIT Service Address: 1425 - Tehama Avenue Owners Name: 14illiam Baker Date: 4/14/97 Address: 2231 St. George Lane Acct. No.: Oiicn; M. 95926 A.P. No.: .10-109-024 Phone: 893-9790 s New Unit: 1 house Applicant/Agent: Adding Units: Address: Fees: Phone: Permit: $ 30 00 600 00 Preliminary Review By: Date: Ext. Fees: Remarks: -Connection fees will be those avtilicable at time of SC -OR: 900 DO connection to the sewer collector systClean out ux-) to Lateral 7 S ' f) grade , required at property line. Other: Total Fees: 1605130 Amount Paid: 160S.00 Collected By: S, Fox Finaled By: Date: Location: Size Line: Signature of Owner/Agent: MONTHLY SERVICE CHARGES WILL COMMENCE AUTOMATICALLY UPON COMPLETION Date Billed: Computer: Paid SC -OR: A.P. File: Blue Book: (R.F.C.) Paid SC -OR: Meter Book: (S/C HG's) Rev. 6/95 RESIDENTIAL PLAN CHECKING GUIDE J SINGLE FAMILY, DUPLEX AND MISCELLANEOUS ONLY OWNER: &'�g y BUR DINGPERMITNUMBER: % l PLAN CHECKER: A P. NUMBER: 0- D GENERAL- Zoning requirements: (side yards and number of permitted living units). Valuation. Plans signed by designer. Proper description of work on application. 5' Existing violations on property. Items on data sheet, (Impact Fees, Environmental Health, Developer Fees, etc.). Recorded notice of violation. A ANO Complete parcel size and dimensions. Setbacks, side yards, easements, etc. Other buildings or structures. Grading, fills and/or drainage. Flood hazard. Special conditions on creation map (Noise, S.R.A., Fire Sprinklers, Water Tender, Trees, etc.). F.A.U. & F.A.S. road setback. Building or utilities across lot lines (Record form). Complete to scale plan with dimensions. Required windows for light and ventilation (Section 1203). Required windows for second exit (Section 310.4). Skylights (Section 2409 & 2603.7). Glazing in Hazardous Locations (Section 2406). Required room sizes, ceiling heights (Section 310.6). G.F.C.I. in baths, garage, kitchen, wet bar and exterior outlets (N.E.C. 210). Lights, switches, receptacles, and exterior receptacles for maintenance of mechanical Location of water heaters, heating and cooling equipment, other electrical Garage firewall, door size and closer (Section 302.4). Minimum of one 3'0" exterior door (Section 1004.6). Fireplace and wood stove location, alcoves and clearance. Smoke detectors (Section 310.9.1). Plumbing fixtures, water closet clearances and shower size. equipment. or gas equipment. Conventional Construction - Unusually Shaped Buildings (Section 2326.5.4). Standard bracing or engineered design (Section 2326.11.3). Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Elevations and wall construction details complete enough to construct building. Roof construction details complete enough to construct building. Rafter ties or bearing ridge beam. Fireplace construction details and calc. if necessary. Garage door and/or porch header sizes. Stud heights. Adobe soils - special foundation design. Retaining walls requiring design. Special Inspection requirements. Header size. Sheetrock nailing inspection required? July 1996 3.2 MISCELLANEOUS ITEMS TO LOOK OUT FOR: Stairway details: landings, rise and run, head clearance, handrails (Section 1006). Guardrail details (Section 509). Brick or stone veneer (Section 1403). Exterior plaster - weep screeds (Section 2506). Proper roof pitch for roof covering (Section 1501). Roof covering type - (fire hazard). Foam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation requited on garage side including supporting walls and posts. Two exits on three - story dwellings (Section 1003). Underfloor.access and ventilation (Section 2317.7). Attic access and ventilation (Section 1505). Combustion air for fuel burning appliances - L.P.G. requirements. Noise requirements on duplexes. Energy design. Flashing at all exterior openings. C.D.F. r requirements If A •® U l July 1996 3.3 NOTE: Read the entire instruction manual before starting the installation. This symbol -4 indicates a change since the last issue. Index Pago SAFETY CONSIDERATIONS ........................................••••.•.•1:2 Clearances From Combustible Matcriuls .............................. 1 Dimensional Drawing...............................................................2 ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE........................... ............................................. 2-3 INTRODUCTION..........................................................................3 LOCATION................................ ............................ ....... ............. 3-4 General......................................................................................3 Location Relative to Cooling Equipment.................................3 Huzurduus Locations .................................................... ......... 3-4 A.iR FOR COMBUSTION AND VENTILATION ...................4-5 UnconfinedSpace.....................................................................4 ConfinedSpace......................................................................4-5 SUPPLY -AIR PLENUM INSTALLATION (DOWNFLOW),.5-6 Installation On a Concrete Slab...............................................5 installation On a Combustible Floor....................................5-6 HORIZONTAL ATTIC INSTALLATION...................................6 Construct a Working Platform.................................................6 InstallFurnace...........................................................................6 HORIZONTAL CRAWLSPACE INSTALLATION ....................6 FILTER ARRANGEMENT.......................................................6-7 GASPIPING............................................................... .... ............ 6-7 ELECTRICAL CONNECTIONS...............................................7.8 215-v Wiring ................................. ...................... ............ ...... .7-8 24-v Wiring...............................................................................8 Acccssurics................................................................................ti VENTING................ ........:.................... ....:...------ ..................8 START-UP, ADJUSTMENT, AND SAFETY CHECK ......... 8-14 �euerat ...............................................................................9-10 rJ quence Of Operation...........................................................10 HeatingMode..........................................................................10 CoolingMode.........................................................................10 Continuous Blower Mode.......................................................10 HeatPump Mode....................................................................10 Start-up Procedures............................................................10-12 Adjustments.......................................................................12-16 Set Gas Input Rate ..................................................... ....12-15 SetTemperature Rise........................................................15-16 Set Thermostat Heat Anticipator............................................16 Check Safety Controls .......................................................16-17 Checklist............................ . .....................................................17 SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified person- nel should install, repair, or service heating equipment. Untrained Personnel can pert'orrn basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When wurl:ing on heating equipment, observe precautions in the literature, ort tags, and on labels attached to or shipped with the unit and other safety precautions that may apply. Cancels: 11 373L-35.1 I 11 W OL -O0- 10 5-96 EFFICIENCY 7 Aima t�A6 `r9�c►vvaorao / 4181A No 6' U!� TABLE 1 --CLEARANCES FROM COMBUSTIBLE MATERIALS (IN.) Indicates supply or return aides when furnace Is In the horizontal position. minimum Clearance ao clearance from routlet the vent nd- The inlet nmaintaind must combustiblematerials when using single-wall vent, $ Minimum 15 -In. front clearance required for alcove. NOTES: 1, Provide 30 -In. front clearance for servicing. An open door In front of the furnace can meet this requirement, 2. A minimum clearance of 3 In. must be provided In front of the furnace for combustion stir and proper operation. 3. Line contact is permitted as shown In Fig. 7. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA No. 54-1992/ANSI 2223,1-1992 and the Installation Standards, Warm UNiT SIZE 060 AND OTO 008-135 DOWNFLOW In Alcove or Closet) Sides Sin le -Wall Vent Type B-1 Double -Wall Vent 1 0 0 0 Back 0 0 1 1 -Top Front Single -Wall Vent Type 6-1 Double -Wall Vent et 3t et 3t Vent Single -Wall Vent Type B-1 Double -Well Vent e 1 e 1 HORIZONTAL (Attie, Alcove, or Crawiepace) Sides ' 1 0 Back 0 0 Top Single -Wall, Vent 1 1 Type B-1 Double -Wall Vent 1 1 Front* Single -Wall Vent Type B -t Double -Wall Vent 6t 3t 6t 3t Vent Single-wall vent Type 8-1 Double -Wag Vent 8 1 6 1 HORIZONTAL. (In Closet) Sides 1 1 Back 0 0 Top Single -Wall Vent Type B-1 Double -Wall Vent 2 2 2 2 Front Single -Wall Vent Type B-1 Double -Wall Vent 6 3 S 3 Vent Single -Wall Vent Type B-1 Double -Wall Vent a 1 8 1 Indicates supply or return aides when furnace Is In the horizontal position. minimum Clearance ao clearance from routlet the vent nd- The inlet nmaintaind must combustiblematerials when using single-wall vent, $ Minimum 15 -In. front clearance required for alcove. NOTES: 1, Provide 30 -In. front clearance for servicing. An open door In front of the furnace can meet this requirement, 2. A minimum clearance of 3 In. must be provided In front of the furnace for combustion stir and proper operation. 3. Line contact is permitted as shown In Fig. 7. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code (NFGC) NFPA No. 54-1992/ANSI 2223,1-1992 and the Installation Standards, Warm r 281/2" VENT CONNECTION 1,,t DIA .. 2' THERMOSTAT 20" 1+1C�"� 4 3qe" WIRE ENTRY 13/18"13/1 er u CE ACSSORY I�I 215/18" 7/s" DIA HOLE I POWER ENTRY 39 1 1/2" DIA =� c •� f R.H. GAS ENTRY ACCESSORY DiA- 81,h1. 16 1/15" 7,b" DIA 4 -� 1 3/4" DIA HOLE 1 101/4" I _, �� I l ACCESSORY 1 CTAS ENTRY rJ i i+-1 t/1 B" 135/16" I OUTLET I 1 ��1 VI 10 v4#1 113" ES NOTE: ADDITIONAL 7/84 DIA K.O. ARE AIRFLOW FOR MANGES ER DRILL OLTS(4 PLACES) LOCATED IN THE TOP PLATE IN HORIZONTAL POSITION AND BOTTOM PLATE F'IE, 1--Ulmaoslonal Orlswing •�lr\IRNA\ILS 11\I 1 1"TVP 5,g" TYP A88324 UNIT SIZE 024050 036050 A 14.3116 14.3116 0 12.9/16 12-9/16 �. E 12 11118 12.11116 VENT CONN 4 _ 4 ®HIP. INT Lb 124 iar 024070 14-3116 12-9/16 1�12-11/16 4 141 _ _036070 14.9/18 12-9116 12-11/16 4 145 038005 17-112 15.7/8 16 4 164 046086 _ 046115 17-1/2 17-1/2 15-7/8 y� 15-718 _ 16 4 154 16 4 171 448115 •- 21 1®-318 — --19-1 /2 4 181 080138 24-1/2 n•7!8 23 5 192 Air Renting and Air Conditioning systems (NFPA 90% ANSUNFPA SOB. In Cunadu, refer to the current edition of the Natinnal Standard of Canada CAN/CGA-B149.1- and ,2-M05 Natural Gao and Propane Installation Codes (NSCNOPIC)^ Wear 3"fety glasses and work gloves. Have fire extinguisher available during start-up and ;Adjustment procedures and service calls. Recognize safety information. This is the Safety -alert symhul When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury. Understand lite signal words DANGER, WARNING, and CAU - 110N. These words are used with the safety -alert symhul. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in pervunal injury or death. CAUTION is used to identify unsafe Prllctice.s which would result in minor personal injury -or --product and property damage. These instructions cover mi.nimunt requirements and conform to existing, national standards and safety codes. in some instances, these instructions exceed certain local codes and ordinances, especially those that may not have kept up with changing re&ialen tial construction practices. We require those Instructions as a minimum for a safe. installation. —2— ELECTROSTATIC 018CHARGE J8D) PRECAUTIONS PROCEDUR CAUTION; Electrostatic discharge can affect electronic components. Talo precautions during furnace installation and servicing to protect the furnace electronic control. Precautions will prevent electrostatic discharges from personnel and hand tools which are held during the, procedure. These precautions will help to avoid exposing the control to electrostatic discharge by putting the furnace, the control, and the person at Iho same electro- static polnntiai, 1. Disconnect all power to the furnace. DO NOT TOUCH THE CONTROI. OR ANY WIRE CONNECTED TO THE CONTROL PRIOR TO DISCHARGING YOUR BODY'S ELECTROSTA 1C CHARGE TO GROUND, 2. Firmly touch a clean, unpainted, metal surface of the furoacc chasslfl Which is close to the control. Tools held in a person's hand during grounding will be satisfactorily dischargcd. W.WN bad LAND DEVELOPMENT BUILDING / ENVIRONMENTAL HEALTH - PERMIT CLEARANCE Building Peimitft. �- OSI?l �I2/cEi2 son/ OWNERS /I A.P. /� 3 NAME: V)' / ` y `� NUMBER: Lj PRINT LAST NAME FIRST ! COUNTY ZONING /� �j 1f rt DESIGNATION: f'[I FLOOD ZONE: FLOOD MAP: APPROVED: Y CONDITIONALLY APPROVED: V RESOLVE PROBLEMS PRIOR TO APPROVAL: PARCEL CREATION BY DEEDS DEED INFORMATION: DATE OF CREATION: LEGAL ACCESS PROVIDED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: COMMENTS/CONDITIONS: OR MAP t� ����/^'i fl i q FrEs ? DEED REFERENCE: LEGAL ACCESS REQUIRED: YES NO YES NO MAP INFORMATION: �7 p DATE OF. RECORDING Z S Z '!LOT G— BOOK R8 PAGE �a COMPLIANCE WITH OLD SUBDIV ION LOT ORDINANCE REQUIRED? (MAP RECORDED -PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DIVISION UNLESS OTHERWISE NOTED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a ft.building setback from right-of-way/centerline of _ 3. Comply with Zoning code for building setback from road. 4. Maintain a 100 ft. leachfield setback from all existing wells. 5. Maintain a ft. leachfield setback from 6. Pay water tender fees in the amount of $ to Battalion Number 7. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. 8. Connect to a public water supply. 9. Connect to a public sewer system. of the Butte County Fire Department. _ 10. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. 11. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ _ 12. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) 13. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010. 14. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be'nodle to the Planning. bi dskn. _ 15. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. _ 16. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. X 17. Pay school impact mitigation fees. X 18. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II of the Butte County Code. _ 19. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. _ 20. If any cultural resources are encountered during ground disturbing activities, all work shall cease in the area of the find pending examiF:�Yiee•of the site by a professional archaeologist. This person would then be ab;e :Pcassess the site significance ano suggest appropriate mitigation measures. 21. 22. 23 24 25. 26. AI 3111(8 JO,KMOO 1661 ` E SVW aF,1333H LD 7/96 CAWP51 TORMS.K\BLDGPERM.CLR ,C'ER'TIFICATE OF COMPI.._TANCE: Resi_dent..i.a.l. Page 1 CF -IR -----------------------------------------------------------------------;--------- Project. Tit -le.: RAKER 1.1.81n (BASE CASE) Run: 064 1.8 -Mar -97 Project. Address: I.._OT 24, TEHAMA ST RAKER 1.181n ( RASE CASE) OROVILI._E , CA. Building Tit -le: SAVAGE 1181n (RASE CASE) Bui)(li.ng Permit- Document. ermitDocument. Author: BOB METZGER O.D.S. q 17- (9 sq Telephone: 865-9688 or 342-9688 Plan Check/ :ate Compliance. Method: CAI.._RES2 Version 1.31 Field=Check / Da.t. Cl.i.ma.t.e Zone: 1.1. r_,ENERAI.... INFORMATION Condit-ioned Floor Area.: 1.1.81.. ft.2 RUil.di..ng Type: SFD Single Family Detached Building Front. Ori ent.at..ion: 0 deg ( Nort.h ) Number of Dwelling Unit -s: 1.00 Floor Const-ruct-ion Type: Slab on grade RUIL...DING SHEI....I.... INSUl...ATION Component. InsL,.l Assembly Type R-va.l.Ue U -value I....oca.t...on/Comments ----------------------------------------------------------------------- Door 0 0.330 t_incondi.t.i.oned Wall 15 0.081 Out -side Wall. 1.5 0.081. l_lnc.ond .t.i.one.d Floor 0 0.722 Grade Floor 0 0.295 Grade Ceiling 38 0.02.5 At-t-ic Slab Peri.met.er 0 0.550 Uncondit-ioned Slab Perimet-er 0 0.500 Uncondit-ioned Slab Perimet-er 0 0.900 out -side Slab Perimet-er 0 0.720 Ol,.t.s..de FENESTRATION Area. U- Inter i..or E_.xt.erior Overhang Frame Orient.a.t.i..on ( ft.2_ ) val. ue. panes Shad.i_ng Shading and Fins Type ----------------- ----- ----- ----- ---------- ---------- -------- -------- Window North 20.0 0.650 2 St -d Drape Rug Screen Overhang WdDr/D.iv Window North 25..0 0..650 2 St.d Drape Rug Screen Overhang Metal. Window East. 8.0 0.650 2 St -d Drape Bigg Screen Overhang Met -al. Window East. 1.6.7 0.650 ' 2 St -d Drape Rug Screen OH+Fins WdDr/Di.v Window Sout-h 45.3 0.650 2 St -d Drape Rug Screen OH+Fins Metal Window Sou.t.h 1.7.5 0.650 2 St -d Drape Rug Screen Overhang Metal Window West. 34.0 0.650 2 St -d Drape Bug Screen Overhang Meta 1. Sky1.i.ght. 4.0 0.800 2 None None None Met.a.l. THERMAL._ MASS Area Thick Type Exposed? ( ft.2) ( in ) L.oca.t.i.on/Comment.s ----------------- ----- Fl.00r Yes 275.0 3.5 Grade IT - 0 Floor No 906.0 3.5 Grade �. q� ,CERTIFICATE... OF COMPL...IANCE: Resi.dent.ia.1 Page 2 CF -1.R Project. T.i.t.le: RAKER 1181n (BASE CASE) Run: 064 1.8 -Mar -97 -------------------------------------------------------------------------------- -------------------------------------------------------------------------------- HVAC SYSTEMS Duct. L...oca.t..i.on Type Efficiency and R -value -------------------------- ---------- ------------- For nace 0.78 AFIJE At-t-ic R-4.2 Air Gond. -- cent.ra.l. split. 1.0.00 SEER At-t-ic R-4.12 WATER HEATING SYSTEMS Di.st.ri.h Wa.t.er Wa.t.er # of Energy Volume Wrap System Name Type Heater Name Heater Type Ht.rs Factor (gal.) R-val ------------------------------------------------- ---- ------ ------ ----- 40GALW/H Standard 40W/H Storage gas 1 0.61 40 0 WATER HEATING SYSTEMS MISC Solar savings Solar system Wood stove Wood stove System Name fract..i_on type hoi..l_er? boiler pump? ------------------------------------------------------------ 40GALW/H -- -- No No WATER HEATER/RO.IL...ER DETAILS Rat -ed Pilot. Wat-er Recovery Input. St.andhy Tank Light. Heat-er Name Effi.cie.ncy AFUE ( kRt.uh) Loss R -value (Rt.u.h') ---------------------- ------------------------- ------ 40W/H 760 -- 35.00 - -- -- HYDRONIC DISTRIBUTION AND TERMINAL -S Pipe Pipe insul.. Insul. System/Name Type Number run (ft.) d.iam (in) t.hck (in) R-val.ije --------------------------- ------ -------- --------- --------- ------- None SPECIAL... FEATURES, , REMARKS , AND NOTES None CERTIFICATE OF COMPLIANCE: Res ..dent. _a.l Page 3 CF -1R Project. Title: BAKER 1.151 n ( RASE CASE) Run: 064 1.5 -Mar -97 COMPLIANCE STATEMENT This cert-ificate. of compliance lists the building fea.t.u.res and performance specifications needed to comply with the Energy Standards in Title 24, Parts 1. and 6, of the California Code -of Regulations, and the Administrative regUl.a.t..i.ons to implement. them. This cert.if.ica.t.e. has been signed by the .i_nd.i..v.idua.l with overall. design responsibility. When this certificate of compliance. is submitted for a Single building plan to he built. in multiple orientations, any shading fe.a.t.ure that. .is varied is indicated -in the Special. Feat-ures, Remarks, and Notes section. DESIGNER OR OWNER RAKER CONSTRUCTION 2231. ST. GEORGE ST. SUITE 70 CHICO, CA. 95926 59:3-9790 L... i. c # Signed Date ENFORCEMENT AGENCY Name: Title: Agency: Telephone: Si a n e d Date DOCUMENTATION Al_1THOR BOB METZGER O.D.S. BOB MET7._GER O.D.S. 11.3 E. WAI....KER ORL_.AND , CA'. 95963 865-9655 or 342-9655 i.gned Date a COMPUTER METHOD SUMMARY ' Page 1 C -2R Project. Title: BAKER 1181n (BASE CASE) Run: 064 18 -Mar -97 Project. Address: L0T 24, TEHAMA 5T BAKER 1181n (BASE CASE) 0R0VILLE, CA. Building Title: SAVAGE 13.81n (RASE CASE) Building Permit # Document. Author: BOB METZGER O.D.S. Telephone: 865-9688 or 342-9688 Plan Check / Date Compliance Method: CAI RES2 Version 1'31 Field Check / Date Climate Zone: 11 ================================================================================ ENERGY USE SUMMARY (kBtu/ft2-yr) Energy Use Standard Design Space Heating 19'32 Spaoe Cooling 12'82 ~Water Heating 16'70 Tot -al 48'85 GENERAL INFORMATION Proposed Design --------------- 19.32 13'70 15'79 -------- Complies 48'81 Ye. s Conditioned Floor Area: 1181 ft2 Building Type: SFD Single Family Det -ached Building Front. Orientation: 0 de.g (North Number of Dwelling Units: 1-00 0'081 Number of Stories: 1 90 Floor Cnn-�truntinn Type: Slab on grade Number of Conditioned Zones: 1 0'081 Total Conditioned Volume: 10531 ft3 Conditioned Footprint Area: 1181 ft -2 Ground Floor Area: 1181 ft2 BUILDING ZONE INFORMATION Floor Zone. Area Vnlume Thermostat Name (ft -2) (ft3) Type Type ____________ _______ ________ _____________ ____________ HouSe 1181 10531 Conditioned CEC Standard OPAQUE SURFACES Surface Area U- Insl Tru 5lr Type ��ft2 ) value Rval Azm Tlt Gna __________ ______ _____ ____ ___ ___ --- Zone. = Hnuge. Vent Vent Height Area (ft) (ft2) ______ ------ 210" 13'4 Const -runt -inn Type Location/Comments ------------ -------------------------- Door 16'7 0'330 0 270 90 No 26x68-Wnod Unconditioned Wall 113'0 0'081 15 0 90 Yes W15'2x4'16 Out -Side Well 364'3 0'081 15 90 90 Yes W15'2x4'16 Out -Side Wall 292'2 0'081 15 180 90 Yes W15'2x4'16 0utSide Wall 247'0 0'081 15 270 90 Ye,:.� W15'2x4'16 Out-,ide Wall 221'3 0'081 15 270 90 No W15'2x4.16 Unoonditinned Floor 275'0 -- 0 -- 180 No Slab140E Grede Floor 906'0 -- 0 -- 180 No Slab140C Grade Ceiling 1177'0 0'{)25 38 -- 0 Yea R38'2x4'24 Attic- CnMPuTER METHOD S►_1MMARY GIa.z..i.ng Page 2 C -2R Project. Tit -1e: RAKER 1.1.81.n ( RASE CASE) Run: 064 1.8 -Mar -97 PERIMETER L...OSSES Charact.r Type ---- (ft -2) ----- Azm --- Tl. t. --- Type ------- Type -------- Name Comments ------------ ---------------- Wind I nsu 0 Per imet.er L_engt.h F2_ I nsu l Depth 25 .0 Type -------------------- ( ft. ) Fact.or ------ R-va_l. ----- On) ------ t_.oca.t..i.on/Comment.s ---------------------------------- 7._one = House 90 90 S1 ider Met -al. OPER/st-d Exposed 6'0" 0.550 0 0 Uncondit-ioned Covered 22'0° 0.500 0 0 Uncond _t.ioned Exposed 32'0" 0.900 0 0 Ou.t.si..de Covered 99'0" 0.720 0 0 Out -,Ride FENESTRATION SURFACES Fenest.rat..ion Name -------------- .Zone = House F1.IFRTDR F21 1...1.1 I.._2.1FRCH R1.1.SGD 812 821. R11 R1.2 R13 St 1. GL-AZ_ING CHARACTERISTICS GIa.z..i.ng Above. Glazing Area. TrU # of U- Open Frame Charact.r Type ---- (ft -2) ----- Azm --- Tl. t. --- Type ------- Type -------- Name Comments ------------ ---------------- Wind 20.0 0 90 Fixed WdDr/D.i..v OPER/st-d Wind 25 .0 0 90 Slider Met -al. OPER/st.d Wind 8.0 90 90 S1 ider Met -al. OPER/st-d W.i.nd 16.7 90 90 F.i.xed WdDr/D.i..v OPER/st-d Wind 33„3 180 90 S1. ider Met.a.1 OPER/st-d Wind 12.0 180 90 Slider Met -al OPER/st-d Wind 1.7.5 1.80 90 S1. i. der Met -al. OPF...R/st.d Wind 6.0 .2.70 90 Slider Metal_ OPER/st-d Wind 1.4.0 270 90 Slider Met -al. OPER/st-d Wind 14.0 270 90 S1 i_der Met -al OPER/st-d Skyl. 4.0 -- 0 Slider met -al. DhlSkylt. GL-AZ_ING CHARACTERISTICS GIa.z..i.ng Above. I....eft. Charact.r dazing # of U- SC GIs Name Type Panes Value ----- Only ------ ------------ OPER/st-d --------- Clear ----- 2 0.650 0.880 Dbl.Skyl.t. Clear 2 0.800 0.880 OVERHANGS Fenest.ra.t.i.on I nt.er i.or SC Int. Shade Type Shade ---------- ------ St.d Drape 0.780 None 1..000 Exterior SC Ext. Shade Type Shade ---------- ------ Rug Screen 0.870 None 1..000 -------------------------- Above. I....eft. Right. Name ------------ Height. W.idt.h Depth ------ Glazing Ext.ens.i.on Ext-ension F1IFRTDR ------ 6'8" ------ '1'0" 4'h" --------- 4" --------- 14'11." --------- 73'S" F21 5'0" 5'0" 1 '8" 2'0" 4'8" 31. ,8" L_1.1 4'n" 2'0" 1 '8" 4,10° 13'6" 15'6 l._21.FRCH 6'8" 2'6" 2$61' 4" 1.1.'8" 2'6" R11.SGD 6'8" 590" 2'6" 4" 8'0" 3'2" 81.2 "3'0" 450" 2'6" 4" 4" R21 196" 5101, 118.. 490" 1.5'6" 8901. CC N. 11 I = I I 1: N Or• If LL E I I I u If I N C. i 2: II c f II I 1 = I I 0' > c I 7 11 a' 11 4-� C' n I ^ a' 2; c' x: .� 11 Ii I I I I I N c L Q U.j 2; C) 1 If it If � II Z 2 c!' I N L 1 C 1 1 C7) I ^ tL = 0' 11 L (r.: 1 rt 06 0'• cal "0 a; I .- a II I O)4' I i3) I I II cIIC10- -i x I II Q� UJ I r 1 II C. I II Q 1 C C C n w w n II a' > t= I V., I tr` Z' Lr? -�-) II I ^ c I l;T (`':• N I NN I II 4- 4-) 1 -CIIG0 it 0) 0:° x I n ^ it n I 0` (P. � ti I •� a' • n lL 2 I �vv l II I I OC' CID +3) I w w 1 U:' 11 c a c 1 Ur, W. LC'.- <: If I -I I LL C I L) II I L > r` I it. C Q: i I -C i I I N ti II •�: 13 I I - -�. I IT' it ¢ C+ I I L I OC' ¢ 11 I IJ) I ^ If C. C. C' I I a> I .. II I = t L I Or' OV' CG c II a 1 .- II 0 1 Or' II G I � II CC II I L 1 C O O LL 11 1 1 n n w >- Y II 1 -0. 1 N Of AT it I - i ¢ TO II 1 3 I � n i tf.' II I Ii) I w n n Il I I C:' C:' Ci c n •-� 1 a' i G it C. C 1 1 � -- n •.-I 1 I CC it (5. 2: I I LLI +' II z I I F U It ¢ I I CL F- O II W a I E I N C' e It > 0 1 z I .- 1- L.- , a II C' LL I z I x CC CC a; -- E 2; z U. C 0 0 LL T. --J Cc' m (r� I C I a' I E I E I C' I \ I c I C' I •.-i I 2; I U I � I (r.! 2; 1 c > I c I Q I .-J. I 4-' 1 U I � I +' I � a I G >• I U I-- I I I >• I 4-) 4-:' 1 C C' •-� I C' 7 > I 4' a 1 c�2;rt i > = I �^ I u c I -C •. I I— `r I 0:• N I �- +-� 1 ¢ 4- 1 .,• I Q:' E 2; z CO, a' a' T: T (.:� L N N G N UJ C. oC (1:; 2; rl (r.' u:' CC' a' o,• o 00 CC. ¢' N N r:. r co Lr. Z' N G N (Y. ICK I 1 x cr 23J I = I I 1: 0:' 1 LL E I U.i N I N C. i z •-I c (:' C) 1 = I I 0' > c I 7 I I 4-� C' n I ^ a' 2; c' x: S; .: I N c L Q U.j 2; C) 1 a Z 2 c!' I N L 1 C 1 1 C7) I ^ tL = 1 L I = I N I I I I cal "0 a; I .- ILL C I i3) I I = _ cIIC10- (01 r 1 CID C. I a' > t= I I Iq 44- -�-) C' N I ^ x -C, I NN -CIIG0 0) 1 n ^ c •rf I 0` (P. •� a' 1 lL 2 I r I I OC' CID }, 1 w n c a 1 .c' lD .-� (I;' I -I LL C I I L I \C'CO I -C i I I N �° •� •�: 13 I I I L I OC' Or' O I IJ) I ^ I •r I C. C. C' I a> I I = t a; -- E 2; z U. C 0 0 LL T. --J Cc' m (r� I C I a' I E I E I C' I \ I c I C' I •.-i I 2; I U I � I (r.! 2; 1 c > I c I Q I .-J. I 4-' 1 U I � I +' I � a I G >• I U I-- I I I >• I 4-) 4-:' 1 C C' •-� I C' 7 > I 4' a 1 c�2;rt i > = I �^ I u c I -C •. I I— `r I 0:• N I �- +-� 1 ¢ 4- 1 .,• I Q:' E 2; z CO, a' a' T: T (.:� L N N G N UJ C. oC (1:; 2; rl (r.' u:' CC' a' o,• o 00 CC. ¢' N N r:. r co Lr. Z' N G N (Y. ICK I 1 x cr T. i 1 1 0 cc -- 1: 0:' 1 LL E I I— 2; I u z 1 z •-I T. E 1 11 U- a a• I (r.: W W -&-� I a' 2; c' C: Q (r.: I c L Q C. > �. I a Z 2 c!' I N COMPUTER METHOD SUMMARY Page 4 C -2R Project.. Tit -le: RAKER 1.1.81n (R -ASE CASE) Run: 064 18 -Mar -97 WATER HEATING SYSTEMS Di.st.rib Wat-er Wat-er # of Energy VOILIMe Wrap System Name Type Hea.t.er Name Heat-er Type Ht.rs Fact.or (gal) R-va.l. ------------------------------------------------- ---- ------ ------ ----- 40GALW/H Standard 40W/H Storage gas 1 0061 40 1 0 WATER HEATING SYSTEMS MISC Solar savings Solar system Wood stove Weed stove System Name fract..i_on type boiler? boiler PLImp? ------------------------------------------------------------ 40GALW/H -- -- No No WATER HEATER/BOILER DETAIL...S Rat -ed Pilot. Wa.t.e.r Recovery Input. Standby Tank I.._i.ght. Heater Name Efficiency AFUE (kBt.uh) Loss R -value (Bt-Uh ) 40W./H 76% -- 35.00 HYDRONIC DISTRIBUTION AND TERM.T_NAI.._S Pipe Pipe Insul. InsuI System/Name Type Number run (ft.) d.i..am (in) t.hck (.in) R -value -------------- ------------- ------ -------- --------- --------- ------- None SPECIAL... FEATURES, REMARKS, AND NOTES None MANDATORY MEASURES CHECKLIST: RESIDENTIAL - Page 1 MF -1R Project Title.......... MASTER PLAN Date........ 01/01/9.6 Project Address........ MASTER PLAN --------------------- CHICO, CA. Documentation Author... BOB METZGER 865-9688 ; Building Permit # ; Company ................ BOB METZGER 0 D S i Telephone .............. 865-9688 or 342-9688 ; Plan Check / Date ; Compliance Method...... Cv��v'Ff� 1Z a 6ajafli4Vt- ; Field Check/ Date ; j Climate Zone........... 11 P/�f�L (► h --------------------- ---------------------------------------- ------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere -in the documents or on this checklist o y. BUILDING ENVELOPE MEASURES G -------------------------- ^a Nesign-nforce- ement *150(a): Minimum R-19 ceiling insulation. a 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls ' a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. E to .J 110-13: HVAC equipment, water heaters, snowerneaas ana faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. E-(( 1500): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank.-� *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between Filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation //�� pump time switch. R / A 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot ( 150 Btu/hr.). LIGHTING MEASURES ----------------- Design- Enforce- er hent 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures. IC (insulation cover) approved. Be aware that glazing units (ncludingdoors with .glass j must have permanent NFRC labels. Glazing labels will be -checked against the Title 24 calculations at the time of framing inspection. If the installed U -value is of a lesser value, the Title 24 calculations must be redone, and appropriate changes made to the structure (e.g., this may include additional insulation, addition of screening devices, reduction of window sizes, etc.). Note that an Installation Certification Form CF -6R is required to be posted at the residence proper to the issuance of a Certificate of ;Occupancy. This is in addition to the Insulation Certificate. An i IF APPLIES GENERAL NOTES SHEET E 1, ALL PENETRATIONS THRU THE BUILDING ENVELOPE (CLG. WALLS AND FLOORS)Tb be CAULKED, SEALED OR WEATHER STRIPPED. SHIM SPACES AROUND EXTERIOR DOORS OF THE BUILDING ENVELOPE TO BE INSULATED. 2. ALL EXTERIOR PANELS EDGES TO BE CAULKED. 3. ANY ACCESSESS TO ATTIC SPACE OR CRAWL SPACE FROM CONDITIONED SPACE TO BE FULLY WEATHER STRIPPED. 4. EXHAUST FANS TO HAVE BACKDRAFT DAMPERS. 5. FIRE PLACES TO HAVE. a) O.S. COMBUSTABLE AIR TO F.P. BOX W/ MIN. DUCT CROSS-SECTIONAL AREA OF 6 SO. INCHES b) DAMPERS TO ' 'DUCT ACCESSABLE FROM INSIDE F.P. AREA, c) FLUE .DAMPER TIGHT -FITTING 8 READILY ACCESSABLE d) TIGHT -FITTING F.P. DOORS OR HEAT CIRCULATING DEVICE. 6, A/C DUCTS TO BE INSTALLED PER 1l'1.l U.M.C. 8 INSULATED 0- INSUL.- GAS EQUIP.) 8 (2" INSUL.-HEATPUMP EQUIP.) 15# DENSITY TYP. r_ -4_,.V44\. 7. MAIN LIGHTING SOURCE IN ALL BATHS 8 KITCHEN TO BE FLOURESCENT OF 4.0 LUMENS/WATTS OR GRATER. 8. FAUCETS 8 SHOWER HEADS TO BE WATER SAVING TYPE 8 CERTIFIED BY G.E.C. 9. W.H. TO HAVE. a) ]'-On H I GHT PLATFORM. b) . VENT T HRU ROOF. 0 ADEQUATED CONBUSTABLE AIR VENTING_ _ d) R-4 INSULATION 5'-0- TO 8 FROM UNCOND. SPACE. e) R-12 INSULATION WRAPPING. f) R-4 INSULATION ON CIRCULATING SYSTEM. g) CERTIFIED BY C.E.C. 10. GAS COOKING APPLIANCES NOT TO HAVE CONTINUOUS BURNING PILOT LIGHT. il. A/C UNIT TO HAVE a) SIZED 8 CERTIFIED BY C.E.C. b) SET -BACK THERMOSTATS. 12. INSULATION INSTALLER TO BE CERTIFIED BY STATE 8 LOOSE FILL INSULAT- ION TO HAVE MANUFRS. LABLED R -VALUE 13 BUILDER TO SUPPLY TO OWNER ALL INFO. PERTAINING TO THE OPERATION OR TREATMENT OF ALL APPLIANCES 8 DEVICES RELATED TO ENERGY OR WATER USE. 14. ALL WDOS. @ CONDITIONED SPACED DUAL -PANE. DOORS 8 WDOS. TO BE FUL- LY . , WEATHER STRIPPED. 15. CAULK BETWEEN BOTTOM PLATE AND CONC. FLOOR. 16. PROVIDE INSULATION BAFFLES @ EAVE BLOCK VENTS. 17. USE ELECT. OUTLET GASKETS C O.S. WALLS. 18 WATER HEATER TO HAVE P -T VALVE WITH DISCHARGE TO OUT SIDE. 19. REF. FRZRS. FLUR. LAMP BALLAST TO BE CERTIFIED BY C.E.C. CON TRACT- OR -OWNER TO SUPPLY MAKE AND MODEL.