Loading...
HomeMy WebLinkAbout030-170-049, ` ^DAVID HIRONIMUS 30-17-4910.20 Middlehoff Lane, OrovillePernit#5189-80B (install wood030-17-0-04,9 91- 3 P40 3 030-170-049 05-0274 ' HIRONIMUIS, DAVID 23 CHERRY LN, OROVILLE � Cont: OWNTER NEW PRI DET GARAGE ' � BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class: License Number: Dale: Contractor: OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, Improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's Slate License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a. permit subjects the applicant to a civil penally of not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or Improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not Intended or offered for sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or Improve for the purpose of sale.). �. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' Slate License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I am Exempt under Arllcle a Buslness and Professions Code Date--3L:A �c Owner: WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -Insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Is Issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy ,0-1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. PERMIT NO. BP050274 Issued Date: 03/03/2005 APN: 030-170-049-000 Site Address: 23 CHERRY LN ORO Map Index: Description: gar (572) Owner: HIRONIMUS DAVID R & BESSIE R JT 23 CHERRY LN OROVILLE, CA 95965 Applicant: HIRONIMUS DAVID R & BESSIE R JT 23 CHERRY LN OROVILLE, CA 95965 Contractor: License #: Architect: Engineer: Total Square Ft: 572 S.F. Valuation: $13,728.00 d Census Code: CONSTRUCTION LENDING AGENCY This permit is he y Is I hereby affirm that there Is a construction lending agency for the Resolutions t 19110 work performance of the work for which this permit is issued (Sec 3097 Civ.) Name: By. PERMIT EXPIRES Address: yfthe appyCtlble p ovisions of the Butte County Code and/or above fo vyhic ees have been paid. -3-:- 0 ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte County to enter upon the above mentioned property for inspection pur DsesPrint Name: L. A_ vz 1>_ R. � //? oN / s'+�Iy S Signature: �/ /`'AXc �a Date: AL1 R ds Owner ❑ Contractor ❑ Agent for Owner ❑ Agent for Contractor B. C. Building Permit ui-lb-1.14 pg l -� /4. i-ev,., - 4 . ..o BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS 24 HOUR INSPECTION#: OROVILLE: (530) 538-7636 • CHICO: (530) 891-2$34 OFFICE #: (530) 538-7541 ry 6 A FEE WILL BE REQUIRED AT TIME OFAPPLICATION tp' "PLEASE PRINT CLEARLY" Q� to OWNER Last Name 141 t? o � (m L.P5 Name irst Name D�L/l D Address 23 State State City t�/�✓e e e �` State�� Zip o/Sr��S Phone5.3o) 5 3 3 "6 q 3 I Fax CS 3b 5-3 E-mail APPLICANT NAME CONTRACTOR Name L a Address State State City Phone �,o S 3 — 67 / _T_ State Zip Phone Map Book Fax E-mail Planner Lic. # Class APPLICANT NAME ARCHITECT/ENGINEER Name L a Address State State City Phone �,o S 3 — 67 / State Zip Phone Map Book Fax E-mail Planner State License Number APPLICANT NAME Name Address . z &y L a City 020 k/t LL F, State State Zip , 5 Phone �,o S 3 — 67 / Fax(,'3.,) 5 33r`_6 Y 3 E-mail Subdivision Name APPLICANT SIGNATURE X For office use only: Zoning Property Address 2 _� C tog' 2 ,2 y r Flood Zone Cross Street M I v Oe --la (4,D r- i- 4y SRA Yes V No Occ. Type Const Subdivision Name Map Book Page Lot # Planner Date Approved: PERMIT NO. BPVS vZ7 BIN # LOCATION AP# 030— !io—©49 Property Address 2 _� C tog' 2 ,2 y r City �l2cvtc.cE Cross Street M I v Oe --la (4,D r- i- 4y WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address OVER FOR SUBMITTAL REQUIREMENTS U K:IFORMSWILDING FORMS\BldgApplSubRgmts.doc Page 1 of 2 Description or Scope of Work: Sq. Footage 5- ;72_ ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Received by: Receipt #:� r Amount: Bldg Total REV 6-16-04 SUBMITTAL REQUIREMENTS The following drawings and specifications must be -submitted to the Building Division in order to apply fora permit. INCOMPLETE SUBMITTALS, WILL NOT BE ACCEPTED. ALL PLANS MUST BE' LEGIBLE AND IN INK . j ~ Residential; New, RemodeIs,`Additions, and Accessory, Structures: ❑ 1. 3 Site Plans, signed by the pre*er. NO GRAPH PAPER! ❑ 2. 3 Complete sets "of plans, signed by the preparer. NO GRAPHPAPERI OR 3 Sets Engineered plans (if required) with wet signature on plans AND 2 sets of stamped and "sighed calculations. o ' , 3. _ 2 Engineered truss details and layouts (if required) (NO FAXES!). ❑ 4. Letter from Engineer or Architect for truss design review. ❑ 5. 2 Energy compliance design\and supporting documentation. (Note: Not required for additions toV. mobile or modular hom'es.) ❑ 6. 2 Flood Elevation Certificate, wet -stamped and signed (if required). ❑ 7. Detached Accessory Building Form, filled'out by the property owner (if required). ❑, 8. Sanitation and site plan approval from the Environmental Health Department. ❑ 9. 'Metal Buildings: (A) Metal Bldg'Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in, triplicate, (D) Floor plans in triplicate, All of these must be stamped and wet -signed by the engineer:., Mobile, Manufactured, or Modular Homes: ❑ 1. 3 Site Plans; signed by, the preparer. NO GRAPH PAPER ! ❑ 2. 2 Data sheets and installation instruction manual. ❑, 3:- 2 Marriage line information. ❑ 4. 2 Floor plans. c ❑ 5. 2 Engineered Tie Downs or Foundation plans. ❑ 6. Sanitation and site plan -approval from the Environmental Health Department. ❑ 7. 2 Flood Elevation Certificate; .wet -stamped and signed (if required).. Commercial, New, Additions and Remodels: ❑ 1. 4 Site Plans, signed by thepreparer. NO GRAPH PAPER! ❑ 2. 4 Engineered plans with wet signature on plans AND '2 sets of stamped and signed calculations,, with code analysis. ❑ 3. 2 Engineered truss details and layouts (if required) (NO FAXES!). r= ❑ 4. Letter from Engineer or Architect for truss design review. ❑ 5. 2 Energy compliance design,and supporting documentation (if required). ❑ 6.. 2 Flood Elevation Certificate, wet -stamped and signed (if required).- ❑ 7.. Statement of Intent for Non -heated and A/C (if required). ❑ 8. Metal Buildings: (A) Metal Bldg Plans, (B) Fnd plans -and calcs in triplicate, (C) Elevations in' triplicate, (D)'Floor plans in triplicate, All of these must be stamped and wet -signed by the engineer. ❑ 9. Letter of intent. ❑ 10. Hazardous Material Form. r� ❑ 11. Sanitation and site plan approval from the Environmental Health Department. t If you have questions or would like additional information regarding this process, contact a Permit Application Assistant at (530) 538-7541. = i OVER -FOR BUILDING PERMIT APPLICATION KAFORMBUILDING F0RMSUdgApp1SubRgmts.doc Page 2 of 2 REV 6-16-04 utte County Department of Development Services JNNE CHRISTOPHER, DIRECTOR County Center Drive roville, CA 95965 X30) 538.7601 Telephone ;30) 538.7785 Facsimile TO: FROM: SUBJECT: z DATE: �1J T TF 00 11 i i�00 o cOU N'�y WILLDAN Scott Rutherford (530) 538-7160 srutherford(a)buttecounty. net Plans Transmittal For Review Per Contract 2/7/2005 Applicant: Hironimus, David Permit No: 05-0274 Project Type: Detached Garage APN: 030-170-049 100% 70% Plan Check Fees $ 219.96 $ 153.97 $ 219.96 $ 153.97 WILLDAN Fee $ 153.97 Copies Attached: Qty Chk Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other �`...w y"f. ^� �; �r.,ywry-....r„y►r_a.l�.:y.f�,.�.....�„*;5+.�'Ax�'u�..-:�-.-/'.+r�l;;.- .+--�- ��. -•� COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: i�aV / y S /1 y) � ASSESSOR PARCEL NUMBER 030- /%d _(9 7 Proposed Building Use: /"G Counter Technician: rj Date: Ztems required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. f N 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. . �i IN 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Letter from Engineer or Architect for truss design review. ❑ 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or find plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate ❑ 11. Site plan and business license approval from the City of Biggs ❑ 12. Letter of intent for non-residential buildings I N' 13. Detached Accessory Building Form filled out by the owner ❑ 14. Hazardous Material Form \ ❑ 15. Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable. 16. Other_ itsaA,_ -(.-P L �-rrc-� P, -z M -r-i n Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ❑ 17. Fire Sprinklers............................................................................................ ❑ 18. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 19. Soils Report and/or Engineered Foundation required ........................................... ........ ❑ 20 Erosion Control Plan Required........................................................................ ........ 21: ees as shown on the attached Schedule of Fees Due Sheet .............................. ❑ 22. City of Chico Plumbing permit........................................................................ ❑Z3,California Department of Foresyy plan approval ❑ paid. Sent by: 24 fanning approval (A) Use: U(B)Parking:(C) Parcel Check: (� ?-Z-vG� ❑ 25. Contact Land Development about _ Improvements, _ Drainage ......................... 26. NPDES Form............................................................................................. ❑ �N 27. Encroachment Permit for driveway from the Public Works Dept ........................... ❑ 28. Pre -Inspection for required....... ❑ 29. Contractor's license information. (Number, Name Style, Classification) ................... \ ❑ 30. Worker's Compensation Carrier and Policy Number .......................................... 31. Owner -Builder Verification (_ Given to owner, _Mailed to owner) ................:... ❑ 32. Letter of Signature authorization......................................:............................. El 33. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 34. Manufactured home utility clearance............................................................... ❑ 35. Existing violations and/or expired permits......................................................... ❑ 36. Deed Restriction ............................... ................. ........ ............. ""....... ........ ❑ 37. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 38. Other: ❑ 39. Other: When issued Telephone and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. A Applicant: _ _ Date: cD�g FSF3 OS 1. Index permit application for the above items numbered: Plan Check Letter 2. Additional items requir Contractor, designe wn6, as advised of the above data by phone, ❑ mail, ❑ co er, b Date: 3 S Contractor, designer, er, was advised of the above data by ❑ phone, ❑'mail, ❑ counter, by Date: Plans reviewed by: Date: Plans approved by: _ Date Structural reviewed 4y: • Date: Structural approved by: W Date: Note transfer by Date: izlt, Yellow: Building Division COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES — BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 TELEPHONE (530)538-7541 SCHEDULE OF RECEIPT OF FEES OWNER / l /NI WCj Qan/I I� A.P. # 03 PROPROSED BUILDING USE 6-12-0_64ff— DATE L'�1. BUMDING PERMIT FEES 3&LI RECEIPT # DATE REC. ---Balance Due ..................... $ i --- Additional Fees Due........... $ i --- Revised Plan Checking Fee.... $ 2. SCHOOL DISTRICT FEES (paid at School District Office) (form available after Plan Check) 3. SHERIFF FEES (paid at Building Division) Residential............ X $360.00 =$ Units Commercial (sq. ftg.)..... X $0.03 = $ ` 4. URBAN AREA FEES (paid at Building Division) Residential (per unit)..... X = $ # Units Amt. Commercial (Sq. Ftg.).... X = $ Sq. Ftg. Amt. 5. RECREATION DISTRICT FEES (paid at Recreation District Office) (form available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES } $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK FEE $89.00 (paid at Building Division) 8. WATER TENDER FEES BATTALION # $200.00 (paid at Building Division) 9. NORTH CHICO SPECIFIC PLAN (paid at Building Division) Residential Zone X = $ Zone # Units Amt. Commercial (sq. ftg.) ......... X = $ Sq. Ftg. Amt. 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed he plan checking process. APPLICANT DATE CSS Pursuant to Government Code Section 66020, you are hereby. notified that items, 2, 3, 4, 5, 6, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Division Yellow -Applicant Pink -Owner (rev. 2/2003) e t.>.�.Y .tea. •.�:�s. 'C,4' •r :r� t�rca;`'�L ,� ar .-::.fi:•�,.r..' :-c.= ��•.�.:4.,..qc.:,.�,-�on�xw,�'?'z�'..'L'r�1�.'x'^.ii..x._ Attention Property Owner: ,An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. I personally plan to provide the major labor and material for construction of this proposed property improvement: YES [k ] NO [ ]. 2. I HAVE [X ] HAVE NOT [ ] signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise, and provide the major work: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: / n ` PROPERTY OWNER: DATE: © 4- NOTE: This Owner -Builder verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. Rev'd 11/4/2004 Butte County Department ADMINISTRATION • BUILDING' GIS ` PLANNING 7 County Center Drive Oroville, CA 95965 (530) 538-7541 Telephone (530) 538-2140 Facsimile Dear Property Owner: of. -Development Services y.�'a'�k",�"�,''S��'CCi���ah'Rit'h.-, a�'a' �.nig'.�4.'ate'k.�'•3"s�T'¢'T�-`1�csv..g...�F� ti. -:t:.. k..e,. C$; �a�!'r, ''ro��': .- � � ,v.3 '->c+it.:avca^'�.ro. 4..�uc ...aw/svx.AW �. ]i•:.4..?•... azo (� An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your- protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be'signed by property owners unless they are .personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city.or county. They are also required by to'put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that your plan to subcontract, you should be aware of the following information for your benefit and protection: o If you employ or otherwise engage any persons other than your immediate family, and the work (including materials " and other costs) is $200 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. ' o If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and7fedefal income tax withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment compensation contributions. o There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. o - For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, ,. if.you wish,?;the,U.S. Small Business Administration). For more specific information about your obligations. under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale,,property owners who are not licensed contractors are allowed to perform their work personally or through their own employees, without a licensed contractor or subcontractor, only under limited ,,.conditions. A frequent practice of unlicensed persons professing to be contractors is to secure an "owner -builder" building permit; erroneously implying that the property owner is providing his or her own labor and material personally. Building. permits are not required to be signed by property owners unless they are performing their own work personally. - Information about licensed cbntractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N Street, Sacramento, California 95814. Please complete and return the enclosed'owner-builder verification from so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Mic el C. Vieir C.B.O. W M ager, Building Inspection NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. a o))) Department of Public Works C o u n t y o f B u t t e -J. Michael Crump, Director LAND DEVELOPMENT DIVISION Storm Water Management Program 7 County Center Drive A `: 5 Oroville, CA 95965 V@C1C WC�� (530) 538-7266 (FAX) 538-7171 National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement [LESS THAN 9 ACRE l - Project Description: -57 7Z. SQ FT�.a-G-,� Project Location and/or Parcel Number: _ ? -- -. A 030— 7O--o�� w" By signing below, I, 4he project owner/owner's agent, certify that this project WILL -NOT DISTURB - L� � 1= -acre or more of land A&_tliat:l,=therefore, do not need.to-apply fo a_Construeti'on Storm Wafer Permits • .��� .`- frairiLthe Statek.01- GalifoFnia Regional•Water Quality -Control ;.Bdard-,•�•Phased�-projects tlat coritahn=�.1.':�` M-rrlulhple'srte'�bulld=outs-O'Hess-than one acre but when - combined _with-subsequent�phases:�total.more:, - than one= acre -of- disturbed- soi-1 will require a Construction Storm -Water Permit from -the-State .of.><}.....-_ California Regional Water Quality Control Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions provided by law. Signed: Title: Date: ¢ IL: 16 1 o� Less than l Acre NPDES & SWPPP Compliance Certification Butte County Storm Water Management Program Revised 5/24/04 i4>X/ IM w eY. i 3 f 3 �1 . sy °c, a _ 1 YM .g v f 1 , Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX DETACHED ACCESSORY BUILDING OWNER'S STATEMENT OF USE Plan review will not be started until this form is completed, signed by the property owner, and returned to the Butte County Building Division. Attached Accessory Buildings and Additions will be checked for residential use. Exception: Garages and Carports. Owner: _Q,-2,,vio (4(2et:, at M Us Phone: (S 30) 533-C= � 3 Mailing Address Z 3 CFF_ z Site Address: 2_3 Gt-fX22 C,�{.mac , O�o�<<-Lr=, Cdr ct5C?'6S' Assessor's Parcel Number: O 3,0 - C 7c,• -meg q Zone: /-N - R Please answer questions 1-16, and explain any yes answers for questions 2-14 in the space provided on page 2 of this form GENERAL LNFO%MATION: 1. Is there a primary dwelling on the property? yes ER No ❑ 2. Is the structure already built, under construction, or under notice of code violation? Yes ❑ No Q 3. Will items produced in this building be offered for sale? Yes ❑ No 4. Will the public have access to this building? Yes ❑ No Q 5. Will any advertising, on or off site, be associated with the use of this building? Yes ❑ No SITE CONDITIONS: 6. Is the structure foundation within 5' of septic tank or 10' of leach lines? Yes ❑ No 91 7. Is any portion of the structure located closer than 20' to your front property line? Yes ❑ No 0 S. Do you plan to add a driveway or modify existing access to a,county maintained road? Yes ❑ No 9. Will the proposed structure encroach within any recorded easement? Yes ❑ No Q CONSTRUCTION FEATURES: 10. Will this building have insulated floor, walls, or ceiling? Yes ❑ No �) 11. Will this building be heated or cooled? Yes ❑ No IS 12. Will this building have a water closet/toilet? Yes C No 13. Will this building have a sink? Yes C] No Q 14. Will this building have a water heater? Yes ❑ No.® 15. What type of floor covering will the building have? &,a.JZ r_— 16. What type of wall covering will the building have? 0 P 0/,-( 5Tu D 5 OVER 1 of 2 M PROPOSEWUSE: (check only one box) 1. ❑ Residential Storage Shed — I will be storing in this building and it wi l .4' ' not be used for any other purpose (no bathiro r t'"and no heating or cooling). 2. ®'Private Garage — "A building or'a portion of a building not more that 1,000 square feet (3,000 by- exception) in area in which only motor vehicles used by tenants of the building or buildings on the premises are,, stored or kept." Ajearage door is'reouired 3. '`❑.Residential Carport - A covered structure intended for parking of vehicles. Two or more sides must be entire open. 4. ❑ Residential Occupancy = Strictures meant to be occupied, as opposed to a storage shed, garage, or carport - If you arportIf.you checked #W, please check''the uses below_ which best fit this building ❑ GuestHouse 1:1Pool House' O Studio Apartment ❑ In-law quarters ❑ Recreation Room ❑ Game Room ❑ Study ❑ Library ❑ Bonus Room ❑ Playroom . r C3 Den El Studio ❑ Artist Studio- ❑ ❑. Hobby, Room „ ❑Craft Room • ❑ Sewing Room Canning Kitchen O'Music Room • • ❑ Fanuly.Room „ ❑Sun Room . ❑ Private Office ❑ Workshop ', ❑ Honie Occupancy 2 ❑ Other— Use I. Describe type or Wotbhop I Must be approved by the Butte canny hwwing Division ..Explanations: This area is for explanation of any "yes” answers on questions 2-14. Please indicate the question number before the exxplanation. .. • r Fad \ \ • • F Additional Information: 6-• Plan review will not be started �until'this form is completed and received. A Plans Examiner will contact the"+ ' owner with specific requirements per the use indicated.,;i".t�• t' I hearty affirm under penalty of perjury that the above information is true and coned I understand that any changes:'' to the use, or character of use, of this building will require permits from the permitting authority. I understand that I ` Real Estate Disclosure laws require disclosure of this information if or when the property is offered for sale 0«rer's Name: Please Owner's Signature: Date: 2of2 117 C Street //�\� VV W I LLDAN Marysville, California 95901 Serving Public Agencies 530/749.2373 fax 530/749.2199 www.willdan.com March 1, 2005 Scott Rutherford Butte County Building Department 7 County Center Drive Oroville, CA 95965 (530) 538-7169; ' (530) 538-2140 FAX SUBJECT: COUNTY OF BUTTE PLAN REVIEW APPROVAL Willdan Project No: 14353-1378 Jurisdiction Job No: 05-0274 Assessor's Parcel No: 030-170-049 Applicant: David Hironimus Description: New Detached Garage Dear Mr. Rutherford: Willdan has completed a plan review of submitted plans and documents for the above referenced project and recommends your approval with the conditions noted on the 2"d page of this letter. The plans and documents provided for this review that have been found in compliance with the applicable codes are: Plans: Two (2) copies dated 2/3/05, by Jerry Mitchell. The plans have been stamped with the Willdan approval stamp and dated the date of this letter. According to our previous letters relating to this project, the superseded plans and documents will be discarded within 10 days unless we. receive other instructions. r On the pages to follow is the identification of the codes and standards applicable to the project, a code analysis, conditions -of -approval and identification of any deferred submittals. ti.. W I LLDAN Serving Public Agencies APPLICABLE CODES Unless noted otherwise, all comments are based on requirements of- the 2001 California Building Standards Code found in the California Code of Regulations, Title 24: • Part 2, known as the California Building Code and abbreviated herein as "CBC" • Part 3, known as the California Electrical Code and abbreviated herein as "CEC • Part 4, known as the California Mechanical Code and abbreviated herein as "CMC" • Part 5, known as the California Plumbing Code and abbreviated herein as "CPC" • Part 6, known as the California Energy Code, and Energy Commission Standards, and abbreviated herein as "CECS" CODE ANALYSIS ' Type of Type of 1" Floor 2 "d Floor Occupancy Construction Sprinklers Stories Sq Ft Sq Ft Total Sq Ft U-1 V -N No 1 572 NA 572 CONDITIONS OF APPROVAL 1. Approval is contingent upon the review, requirements and approval of other departments and/or agencies that have jurisdiction over this project. 2. Revisions and/or notes as red -lined on the plans. DEFERRED SUBMITTALS Our plan review reveals no deferred submittals noted at this time. SPECIAL INSPECTION NEEDS Our plan review reveals no special inspection needs pursuant to CBC '1701. Sincerely, Isaac Kuster Plans Examiner Cc: Alice Mefford, E-mail: amefford@buttecounty.net David Hironimus, FAX: (530) 533-6931, Email: dhironimus@hotmail.com .Pa;e 2 of 2 County of Butte Per nil .Number 05-0274 Wil.l.dan P.roiectNurnber 14353-1378 q SITE PLAN REVIEW APPLICATION Date: • 2, 2605 AP# 03d' 170 & CM Permit Number (if applicable) 05-- 2 7q Bin Number APPLICANT INFORMATION ¢� Parcel Size: Owners Name: llG��`U (' �✓'D�l iv✓! kS Owners Address: Telephone No.: Situs Address: Proposed Use: 23 L"e Residential ❑ New Single Family Residential ❑ Single Family Addition Mobile Home Residential Accessory Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary. Travel -Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other ❑ Septic ❑ Agricultural Exempt Building ❑ Other: ❑ Single Family Remodel ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well ❑ Agricultural Buffer Form ❑ Applicable ❑ 'N/A Brief Explanation (if necessary):e DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) Approved ❑ Conditionally Approved ❑ Resolve Problems Prior to Approval Site Plan Stamp Approved By T Date ` 2 - 1,00 Pave 1 of S 0 ALL ITEMS. CHECKED APPLY TO THE PROPERTY Parcel Is In: r ❑ Snow Load Area: } Y: ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See, Envirorim"ental Health for standards) ❑ Watershed Protection Overlay. Zone (See attaelied standards and requirements) ❑ - Expansive Soils (Test for expansive soils and'if verified proper foundation design required) Ej • SRA - (CDF to determine specific requirements) ❑ .100 -Year Flood Plain: (See attached) :. • Flood Zone: � • Flood Panel No.: Index Date: ❑ . Sacramento River Reclamation District (Approval must be obtained from the California Reclamation°Board) ❑. Feather River. Reclamation•District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards' and requirements) ❑. Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone- (Seer attached handout) a Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ice" ❑ -------=-----------------------------------------------------------------------------------------------------------------------:---- Minor Variance ❑ Variance ❑ Detached Building Use Form. ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement �. Zoning: Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. _t Page 2 of 5 - Zoning. Code Streets & Highways Fire Prevention Subdivision Map Front Side Side Street Rear " Height Waterway N/A, N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. _t Page 2 of 5 - Applicable Development Fees: Standard Fees Amount Formula ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other ------------------------------------------------------------------------------------------------------------------- Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By 10 Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Stanards for Deed �'reation:❑ No ❑ Yes / Comments:<<��,�,_ ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑ Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 Q Subdivision Map/Parcel Map: Map Date of Recording: Lot: Book: Page: ❑ Use Permit/Minor Use Permit 'y Permit Number: Date of Approval: w' Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless -a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. r" ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the'. emission requirements of the,California Clean Air Act of 1988, as amended. .{t. 4. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control'Plan must be prepared by a registered civil engineer or other qualified professional .and be submitted to and approved by the Department of Public Works.' ❑ In lieu of a pressurized water.'system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County -Department ' of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. RON 0 Page4of5 f: 11 c' 7 x 0 Summary of Specific Requirements: This information provided in this summary is based on the application information and on the best available data at the time of review. CALarrys\Building Permit Site Plan Reviewl.doc Page 5 of 5 ...� '-i..'w'-A•'.='p-..;�;h34"',jgf7lT 'rj�.tr'�':rt'r7' , •''LIT'.`•".'"wzi'"1GiR7!%*I-0,r�Cy';l{ J'ir�T:•.:`�i�A:.."..11".?'}�*. COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS ERMIT. NO. f=// 7 County Center Drive - Orovllle, call tprnla 95955 - Telephone: 916.'538-7541 APPLICATION ANDARMIT f A59ESSORRRCEL s •�yNU BERA� - 030'-1 ! 0 "049 ' . t ,ZONING AR BUILDING PERMIT OWNER - DAVID HIRONMUS TELEPHONE SO. FT. OCC. BUILDING VALUATION 18 BUILT UP I, OWNER'S MAILING ADDRESS N - -1 ,y, 23 CHERRY LAND OROVILLE ." CONTRACTOR'S NAME R & H ROOFING TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee ,$ 15,00 Permit Fee $ 34.50 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ' Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 23 CRERRY LANE OROVILLE Permit fee $ 49/, (��50 PLUMBING PERMIT Filing Fee 15.00 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE r SF%J Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 . Building sewer 15.00 Mobile Home S I G I W @ 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ® Describe work: __-REPAIR ROOF COVER _ Permit Fee — ". ' Contractor ," ELECTRICAL PERMIT Filing Fee 15.00 Main service 600VORLESS 200A OR LESS 18.50 Main service 200A TO t000AI 37.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license Is In full force and effect. License No. Classification ElI, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason OCCUP.9 NEW CONST. / DWELLING OR ADONS. ACC, BLDGS. I/ 1 3.64sq.ft. NEW CONSTR ULT' -OUTLET NO N-11 ESI D• BRANCH CIRC ITS @ 5.00 POWER APPARATUS 6 SINGLE OUTLET CIR. Ex. Occup( OUTLETS OR FIXTURES 20 V 764 A FIXED Ex. Occup. OUTLETS PIRESID IREA.) i 3.00 Temporary service 15.00 Mobile Mobile Home Facilities 15.00 M Ho 9 15.00 Permit Fee $ — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ® I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIirig Fee 15.00 Heating Cooling g Hood 6.50 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County or Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue aga,,�st'said County ' connsseequeryce of tie granting of this permit. t� X'" ��"y'�w' �`F'y'" "^^^^ Date�� SNS 7/ Signature of Applicant — Owner Contractor ❑ Agent ❑ An OSHA permit is required for excovations•over S'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee S J Energy Inspection Fee $ OCC CONST TYPE I TOTAL FEE . . . $ 49.50 HAz 0FEES IMP FLOOD COF PARCEL PO HD ISSUE This permit is hereby issued under the sions of the Butte County Code and/or WOrk indicate- above for w�ich fees B LRE ORPUBLIC _ PE IT EXPIRE Date applicable provi- resolutions to do have been paid. WORDKS ate 1 f Receipt NO. 101204 49.50 WHITE-D.P.W„ YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT �;�,�..:�: � ..,v, ' _ .: .. �'Y�".�W�.�j�Y9!!!¢'�I�{7�'y".;+4i.2�4."',�' �a:-�r»�V=.fi+•�,:;+ry¢'a�4e=��•� `yib,��--��x �; A. • 7 I 1Y A. 030-17-0-04'9 91-3403 HIRONIMUS, DAVID CONTR: H & H ROOFING 23 CHERRY LN, OROVILLE SF/REPAIR & REROOF C'� • I ` I i r J S 030-17-0-04'9 91-3403 HIRONIMUS, DAVID CONTR: H & H ROOFING 23 CHERRY LN, OROVILLE SF/REPAIR & REROOF C'� ' COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville California 95965 - Telephone: 916.'538-7541 APPLICATION AND PERMIT PERMIT N0. ASSESSOR PARCEL NUMBER 030-170-049 ZONING AR BUILDING PERMIT OWNER DAVID HIRONIMUS TELEPHONE SQ. FT. OCC. BUILDING VALUATION 18 Sq BUILT UP1—,800 OWNER'S MAILING ADDRESS 23 CHERRY LAND OROVILLE CONTRACTOR'S NAME H & H ROOFING TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ 1.800 LENDER'S MAILING ADDRESS Filing Fee $ 15,00 Permit Fee $ 34.50 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS 3 LANE OROVILLE Permit fee $ 49.50 PLUMBING PERMIT Filing Fee 15.00 Each Trap 1 5.00 Solar or heat pump water heater 1 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water9 P P� I In 7.00 Each qas water heater or vent 1 7.00 USE OF STRUCTURE SF� Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 1 5.00 Building sewer 15.00 t Mobile Home S I G I W @ 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other [ Describe work: REPAIRS ROOFCOVER _ 1 .1 Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 0V Main service 200A 6OR 0ESS 18.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason Main service 200ATO1000A) 37.50 DWELLING OCCUP.&\ 3.60 sq.f[. NEW OR ADDNS. CONST. ACC. BLDGS. I NEW CON5TR ULTI.OUTLET NON•R ESII.BRANCH CIRC ITS @ 5.00 POWER APPARATUS e SINGLE OUTLET CIR. ) Ex. OCcup(OUTLETS OR FIXTURES 20 @ 76 FIXEDA APLNS.Ex. Occup. OUTLETS 1PRESID IREA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00- Misc. Wiring g '15.00 Permit Fee $ — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. fel I shall not employ any person in any manner so as to become subject W� to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 1 15.00 Heating Cooling Hood 6.50 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County Of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue aga' Id Countyicon equence of V granting of this permit. X 1`" C''�% Date�3 S�s'7— O/ �j Signature of Applicant — Owner Illi Contractor ❑ Agent ❑ An OSHA permit is required For excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee S Energy Inspection Fee $ OCC CONST TYPE I TOTAL FEE $ 49.50 HAz I DFEES I IMP I FLOOD I CDF PARCEL PD HD I ISSUE This permit is hereby issued under the applicable provi- sions of the Butte County Code and/or resolutions to do i Work indicate abo for ydLich fees have been paid. E R PU9 IC WORKS By Date PE IT EXPIRE Date , Z. Receipt No. 101204 49.50 WHITE-D.P.W., YELLOW -ASSESSOR. PINK -INSPECTOR, GOLDENROD -APPLICANT i COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - OroviV, , Calhornia 95965 - Telephone: 916.'538-7541 APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 1130-/70-O''q ZONING /,g/:? BUILDING PERMIT OWNER P4f/ TELEPHONE SO. FT. OCC. BUILDING VALUATION s ' � � � ov OWNER'S MAILING ADORES , .23 Ni err N 000 9S (5 CONTRACTOR'S N ME TELEPHONE CONTRACTOR'S MAILING AODRE Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is U� LENDER'S MAILING ADDRESS f Filing Fee $ 155,00 Permit Fee $ 39,50 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESSEnergy Plan Checking Fee $ Penalty $ BUILDING ADDRESS 23 CY err L N 006> 95`56S Permit fee i S �%' S > PLUMBING PERMIT ' Filing Fee 15.00 Each Trar^ 5.00 Solar or heat pump water heater 20.001 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 1 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF&;�- Duplex[] Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W @ 15.00 TYPE OF WORK New r- Addition-; Remodel ❑ Utilities ❑ Installation❑ OtherPermit Describe work: eclye2 Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200A OR 00V OR LESS 18.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): 1 am licensed under provisions of Chapt. 9, Div. 3 of the BusinessPOWER and Professions Code and my license is in full force and effect. License ;Jo. Classification J I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason Main service 20CATO 1000A, 37.50 NEW CONST. /DWELLING OCCUP.a) OR ADDNS. 1 ACC. BLDGS. / i 3.6Gsq.ft.l ^,EW CO ST L UI rLET NON.PESID. BRANCH CIRC�'ITS @ 5.00 APP4RATU5 a (SINGLE OUTLET CUR. ) Ex. OCcup(OUTLETS OR FIXTURES RAO Q6d 64 FIXED APPLNS. OR Ex. Occup. ouTLETs IRESID.I EA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee S — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for 5100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 15.00 Heating Cooling Hood 6.50 Ventilation P ermit Fee $ LContractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct - ion of structures over 3 stories In height. Mobile Home Installation Fee S Energy Inspection Fee $ / q OCC CONST TYPE TOTAL FEES HA2 0FEES IMP I FLOOD I CUTARCE7 Ho ISSUE This permit is hereby issued under the sions of the Butte County Code and/or work indicated above for which fees DIRECTOR OF PUBLIC By _ PERMIT EXPIRES Date applicable provi- resolutions to do have been paid. WORKS Date Receipt No. It 6 / � Q 5/_ 1�9s_� ."NITC-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. CaLpEN ADD -APPLICANT 'AA z , . I T f "PERMIT - NO. 5189-80B PERMIT EXPIRES 10/14/81 OWNER DAVID HIRONIMUS CONTR. owner ASSESSOR PARCEL 30-17-49 LOCATION 1020 Middlehoff Lane. orovillE tl J Temp. Power Pole t. Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Service Cal led PG&E Sit> JOB FINALE (Date) ?(Date) Signature�a V = OK 0 = Not OK - = Not Applicable RESIDENTIAL (Single and Duplex) * = Not Ready Date UNDERFLOOR Plans OK except#'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext: Doors -One 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- /. /" Ftg. Depth 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 52. Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/0 -Sewer Test 55. Shear Walls; Nailing -Bolts J 9. Gas Pipe; Size -Anchors 10.E Water Pipe; Test=Anchors-Regulator-Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material' -Support -ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date , Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except #'s 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except #'s 14. Water Ht.; Vent -Access -Combustion Air 15. Water Pipe; Test & Anchors -Nail Protection 57. Smoke Detector 58. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 16. 17. D.W.V.; Test-Fttngs & Anchors -Nail Protection Shower Pan; Test, First Floor -Tub Access 59. Bedroom Exiting 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. 63. Stairs & Rails Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Date Card -BI Date ELECTRICAL Permit OK except #'s 66. Elec. Outlets & Receptacles at Kit. Counter 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr, Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70. Plb.,-Flee. &Mech. Equip. Listed for Location 22. Size Boxes & No. of Conductors -Stapled 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 23. Romex Installed Close to Edge of Studs & C.J. 72. 73. Insulation -Foam -Looked in Attic ❑Yes Guard Rails &`Deck Construction -Post Caps 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 25. 2 Appliance Circuits in Kitchen &Conductor Size 74. Fdn. Vents &!Crawl Hole Door -Drainage & Wood -Earth Clearance Looked, under Floor ❑ Yes 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 27. .Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or At, Insulated Neutral ❑Yes ❑No 75. Following,instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ; ❑Yes 0 N C 28. Service -Riser Conductors & Ground -Main Disconnect 76. Stucco; Brown -Finish / 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77• A.C. Unit; & Cond. Size -115V Outlet ' 30. Clothes Closet Light -Shower Light 78. -Disconnect-Clrnces-Brkr. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. _ 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date Card -BI Date 81. 82. Ventilation throughout House Glass Protection Card B -I Date _ Date Card -BI Date MECHANICAL (Permit) OK except #'s 31. A.C. Ducts; Insulation & Support 83. _ Corrections from Previous Inspections 84. 85. Gas Test -Meters Tagged; Gas -Electric Water'&•Sewer Connected -C/O to Grade -HD Approval 32.. Vent Fan; Exhaust above Insulation 86• Energy Compliance Certificate -Other Certificates _ 33. Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet --- 35. Attic Access & Platform if Furnace in Attic Card -BI Card -BI Date Card -BI Date Date Card -BI Date Card -BI Date- Card -BI Date Card -BI Date. - Card -BI Date _ Card -BI Date Card -BI Date Date FRAMING(Plans) OK except #'s 36. Sills; Proper Material & Anchors Comments at Final`. 37. _ Walls: Studs -Nailing, Spacing & Bracing -Plates -Sound _ 38. Bearing Wallsover Girders & Floor,Nailing , 39. Draft Stop in _ Walls"(ral proof); _ 40: Fire Stops; Furred Ceilings -Stairs -Chases -Tub _ 41. Header & Beam -Site & Bearing 42. 43. 44. Hangers -Post Caps-Anctiors-_Connectors Cing. Joist-Rflr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng. Fireplace Ties or Type A Flue -Fireplace Throat _ 45. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 46. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framing - - (NOTE: Anentry must be made each time you visit,jobsite)"J J = OK 0 = Not OK = Not Applicable * = Not Ready MOBILEHOMES MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except k's -t7-iUning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch YFootings; Size -Depth -Spacing -Connectors _ 3. Sewer; Location -Test -Fall -C/0 -Concrete CJ!Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) Ar -Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing__ 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete -&—.Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; LocatiorrTest-Wrap:/ /"L"ft./ P'Nat. or/ /"L"ft./ /"LPG 6r -Carports; Windows -Doors, 7. Utility Clearance '*---Elec. e Card -BI Date Card -BI Date Card- DateM 3!�� Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except N's 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/0 to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip.w/5'-Circulating Equip. -Pool Lghtg. Boxes -Enc losures- Pane [boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date C COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PE M T NO 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 �/ O APPLICATIDN AND PERMIT . AS ESSOR PARCEL NUMBER ., 7✓r. ZO ING BUILDING PERMIT 1 OWER VI1 TELEPHONE SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING A D SS fNn ' CO RACTOR'S NAMED v. ELEPHONE CONTRACTOR'S MAILING ADDRESS CONSTRUCTION LENDER - �M UNKNOWN Fireplace Total Valuation $ LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER �t LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDI G A DRESS r PLUMBING PERMIT Filing Fee 3.00 Each Trap 2.00 Repair drainage or vent piping 2.00 Water piping LOT NO.SUBDIVISION NAME PARCEL MAP Each gas water heater or vent 2.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF Duplex❑ Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler system 2.00 TYPE OF WORK New ❑ Addition ❑ Remod I ❑ Utilities ❑ Installation❑ Other Describe work: S+c'1+ 0-L� d � Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 3.00 Main service 600V OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.&\ OR ADONS. ( ACC. BLDGS. I 20sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business Elccu and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR MULTI -CUTLET 2,50 ea NO N.RESID BRANCH CIRC ITS NEW CONSTR. ( POWER APPARATUS &) NON-RESID. SINGLE OUTLET CIR. / ( Ex. O50@� OR FIXTURES BAL@10¢ P\o XED A FIXED APP LNS. OR Ex. Occup.(OUTLETS (RESID.) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Mises Wiring 6.25 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 3.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 2.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County/inn consequence Qf the granting of this permit. X G�(�•-� /�(• Dater [SGT ?a Signature of Applicant — OwnerK Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures stories in height. Mobile Home Installation Fee $ Land Development Fee $ TOTAL PERMIT FEE $ OCCUP. GROUP I TYPE OF CONST. PARCEL PD NO ISSUE This permit is hereby issued under the applicable provi- sions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. ,,MECTqR OF PUBLIC WORKS p-7� BY �D/ate PERMIT EXPIRES ate -_IQ s/`% — F f ��over ��3 Receipt No. �t'iV �� WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR. GOLDENROD -APPLICANT NOTES RESIDENTIAL PERMIT NO., 03 - I Td -U49 05 0274, ' HIRONIMLIS; :DAVID 23 CI°IERRY LN, OROVILLE COnt:OWNER i NEW PRI DET GARAGE I i 11 SPECIAL CONDITIONS 11 SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER z 4 CHECKED BY JOB FINALED (Date) /j 'VL- 15- m E - Signature :J=OK 0 = Not OK = Not Ready Card B-1 Date Card B-1 MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 2. 1. Zoning Requirements -Setbacks -Easements Gas; MH Test -Demand -Valve -Connector 2. Soils; Special MH Support Sketch 5. Drain; MH Test -Fall -Flex Connector 3. Sewer; Location -Test -Fall -C/0 -Concrete 7. 4. Water; Location -Test -Easement Needed (Sketch) Gas and Electricity Tagged 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete r •. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or/ /" L "ft./ P LPG 7. 7. Well Clearance & Disconnect Gas and Electricity Tagged 8. Utility Clearance 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DEC COVERS, CARPORTS, RAG tans) OK except #'s -t/Zond Requirements-Setbac - asements 2. otings; Soils -Size -Depth -Spacing -Connectors -St .17 9,vv 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors t 7,1"Electric ll j,.; W Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 1 Y. t.; Steps -Doors -Landings Cltl-,Ir1JK Braced Wall Panels kA . . - i . r 1. Setbacks -Easements } 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness } Dead Men -Lining p 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Panelboards-Ins. to Main Conduit } 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 GAS ��G/ 5Gi4 aie �% 7 G 1,2 J=OK 0 = Not OK = Not Applicable . = Not Ready FRAMING (Continued) RESIDENTIAL (; Date UND FLOOR (Plans) OK except #'s 48. ng -Setbacks -Easements -Flood -Slope 2/Ftg., Main; Soils-Elec. Gr .-/ . /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel- Bloc kouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped _ 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test. 12. Electric Underground I ' 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation Date 16. Insulation Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s Card B-1 Date Card B-1 Date Ext. Steps -Door & Sidelight Protection -Landings Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance Date 74. Card B-1 Date Card B-1 Date 75. Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s . A.C. Duct in Garage -Damper 24. Fixture & Transformer Clearance -Ins. Protection Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 25. Elec. Receptacles Spacing -Lights & Switches at Doors Plb.; Elec. & Mech. Equip. Listed for Location 26. Size Boxes & No. of Conductors Stapled Elec. Receptacles in Garage (F.F.I.)-Romex Protection 27. Romex Installed Close to Edge of Studs & C.J. Insulation -Foam -Looked in Attic 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water Guard Rails & Deck Construction -Post Caps 29. 2 Appliance Circuits in Kitchen & Conductor Size GA Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al Clearance Looked under Floor 0 Yes 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral 0 Yes 0 No Following Instid./Drive 0 Yes Cl No/Walks 0 Yes O No/Planters O Yes O No 32. Service -Riser Conductors & Ground Main Disconnect Stucco Brown -Finish 33. Equip. Clearances Panels-Motors-Mech. Equip. A.C. Unit Disconnect, Electrical -Plumbing 34. Clothes Closet Light -Shower Light -Spa Light Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 35. Smoke Detector Water Well, Disconnect, Electrical, Plumbing 88. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 91. 36. A.C. Ducts Insulation & Support 92. 37. Vent Fan, Exhaust above insulation 93. 38. Condensate Drain & Overflow, Size & Grade 94. 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 95. 40. Attic Access & Platform if Furnace in Attic Date Fire Sprinkler Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Date 41. Sills Proper Materials & Anchors Comments at Final: 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing tingle & Duplex) Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor 0 Yes 83. Following Instid./Drive 0 Yes Cl No/Walks 0 Yes O No/Planters O Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: David & Bessie Hironimus 23 Cherry. Oroville, CA 95965 (530) 533-6931 APN 030-170-049 8T-4 3/4' 5' setb=k r ----------------------------i-------------, I I i I (n j Z t I Z I I G)- 01 � I I mV3z.. 1251 1 z 1 0 f I I I I I r I I 1 I Q Existing Residence CO 1700 SF Single Story ; w Y $1 I o 0 1 N I I I S I I 1 I - I Existing f ' s AC Driveway U j 10% Slope2 0 1 UP Of F_ - t 01 18'-5 3/4' Proposed, t ! o 1 D/way ' 47'-0' 4 18.4 3/t 1 Gate- _ _i Fence ' - ---------- -------------�- • 20' setback N Q ---ll (I -- — —------- i I 4 C�erry lane �- Middlehott Ln, approx 300' ate-, ZIT I � G) O nn- -- --------------------------- 20' r/w Easement 2'-8" .. A�TERNarE w P CV N W-1 I GX7 SECTIONAL DOOR ,3 112" X 13 112" GLB X DHF -1 .8E GLB see detail 1, 5WjFET 6 41- 2 11-4 11211 — DAVID AND DE551E HIRONIMUS 23 CHERRY LANE OROVILLE, CA 95965 14 nnP. CV 2030 see detail I 1 3068 13 d - N Ln 4'-7 11211 [iss l�rireo twa stamp Q3 meeting thea appmable p7ovia10n3 ®7 fornia Code of RopleftM We 24. Aot aWrOval W violate any epplic" code: The plan inctemtsd the WAowing sWWW. n°) Y svuctunm Fire We e Safety Energy ®1� Electrical% Access WV i. _ j/ Mechanical Other Pian Reviemr Principal Pla°f R mom Aye 3 / 1 11211 x 10" ANCHOR BOLTS GO.C. W/ 2"X2"X3/ 1 G" 5Q. WA5HER5, 12" FROM ENDS AND JOINTS OR USE 51MP50N MAS FOUNDATION ANCHORS. BRACED WALL PANELS TO BE 4'X 8' 8" O.C., 7/1 G" LP -SMART BOARD 8d@G: 12 FLOOR PLAN SCALE: 1/4"= P -O" * 4" THICK SLAB * 12" X 12" FOOTING * G X G X 10 10REME51-1 -RPIR4 MAR 01 2005 * r a 41 1/2" REBAR 2 RUNS v ��yy g Jerry Mitchell BUTTE COUNTY "Or" Waraom BUILDING DIVISION �r�o: soy >Ile3s isridley, CA 95948-1038 APPROVED (530) U&4409 2XG@ I G" O.C. RAFTER5- W/2X8 CR055 TIES @ 4' O.C. 2X4 OUTRIGGERS @ 4' O.C. TYP '93UTTE COUNTY Gm ULDIN UIVISIOE:' APPROVED 7/1 G" 055 SHEATHING NAILED OI 51MP50N H I CLIP OR.EQ. @ EA. RAFTER TO TOP PLATE. W/8d@G:G: 12 OVER 15# FELT OVER 2XG@ I G" O.C. ROOF PLAN SCALE: 1/4"= I'-0" e Z Jerry Mitchel Mitchell's Building Materials Warehouse P.O. Boz 1038 Gridley, CA 95948-1038 (530)846-4409 0 I 2X 5 R DGE BE NM i - - I - -� 2X4 OUTRIGGERS @ 4' O.C. TYP '93UTTE COUNTY Gm ULDIN UIVISIOE:' APPROVED 7/1 G" 055 SHEATHING NAILED OI 51MP50N H I CLIP OR.EQ. @ EA. RAFTER TO TOP PLATE. W/8d@G:G: 12 OVER 15# FELT OVER 2XG@ I G" O.C. ROOF PLAN SCALE: 1/4"= I'-0" e Z Jerry Mitchel Mitchell's Building Materials Warehouse P.O. Boz 1038 Gridley, CA 95948-1038 (530)846-4409 0 12 4F OVERLAP T.P. @ CORNERS 2X4 TRIMMER TYP 2X4 P.T. 51 LL PLATE FIN. GRADE 2X4 @ I G" O.C. 4X 1-2 2X8 RIDGE 2X8 WALL TIES @ 4"' O.C. 4X 12 2XGRAFTER5 �@ I G" O.C. SIDING NAILING: 8d HD GALV. 4" CORNERS, 8" JOINTS, 12 FIELD 5HEARWALU ROOF NAILING: 8d HD GALV. G"EDGE5, 12" FIELD 2X4 P.T. 51 LL 112"0 X 10" IF DT BOLT @ G" O. C. W/2"X2"X3/ 1 G" 5TL. PLT. WA5HER z41 #4 KEBAR CV 2" MIN. FOUNDATION DETAIL SCALE: I"= P-0" FILL 20 YR. 3 -TAP COMP051TION ROOFING 0/(,4 15# FELT O/ 7/1 G" 055 ---- 2X BLOCKING TYPICAL SECTION FRAMING SCALE: 1/4"= 1'-0" ` Fc=2500 psi 1 IMAid ap —2X4@ I G" O.C. CONCRETE FOUNDATION MAR 01 2005 I Y... BUTTE COUNTY BUOHLDING DIVISION 3 APPROVED Jerry Mitchell Mitchell's Buildink Materials Warehouse P.O. Boz 1038 Gridley, CA 95948-1038 (530) 846-4409 I P REAR ELEVATION SCALE: 114"= 1'-0" 1 All V 1 Q 11 /'ACI C% /C A IT d BUTTE COUNTY BUILDINGOMISION LEFT ELEVATION SCALE: 1/4"= 1'-0" 4 MAR 01 2005 Jerry Mitchell MitcheHIs Building Matgrials Warehoust P.O. Boa 1038 Gridley, CA 95948-1038 (530) 846-4409 R 7/1 G, FRONT ELEVATION SCALE: 1/4"= 1'-0" 1 All \/ 1 1011 /� AMI C \ /C\ IT RIGHT ELEVATION SCALE: 1/4"= 1 "-011 L3UTTE COUNTY Iron- ntVISION P PROVED S o� q. GRADE Jerry Mitchell Mitchell's Building Materials Warehouse P.O. Boa 1038 .Gridley, CA 95948-1038 (530) 8464409 w �. * � � " "i