Loading...
HomeMy WebLinkAbout030-193-01730-193-7 ./% North Sierra Const. 1254 Dodge St., lot 7 & port.8, Oro. Permit #ll24-78B,P,E,M(newsile Ai�� �, family) c1700 t P,?�MIT NO.' 1124-78B,P,E,M r o PERMIT EXPIRES CX lA� Ar f 0;WNER North Sierra Const. CNTR. owner. LOCATION (A.P. 30-193-7 port ) 1254 Dodge St., lot 7 &.port.8, Oroville .$i D r t i' i t i+} Y' Temp. Power Pole _ Called PG&E s, Temp. Elea Serv. Called PG&E _ l Temp. Gas Serv. }j Called PG&E 1; JOB t FINALED (Date) (Signature) , i r THIS IS TO CERTIFY THAT INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE CURRENT REGULA- TIONS, CALIFORNIA ADMINISTRATIVE CODE, TITLE -T5, STATE OF CALIFORNIA, IN THE BUILDING LOCATED,AT: Dodge Street Lot 7 Street Lot Number Tract No. EXTERIOR WALLS Manufacturer Certainteed Thickness/Type 3z R Value 11 CEILINGS Batts: Manufacturer ' Thickness R Value Blown: Manufacturer Certainteed Thickness 8 3/4 No. Bags 23 Wt./Bag Sq. Ft. Covered 1150 R Value 19 FLOORS - Manufacturer Certainteed Thickness/Type ��' R Value 11 SLAB ON GRADE Manufacturer Thickness/Type R Value Width of Insulation inches FOUNDATION WALLS Manufacturer Thickness/Type R Value GENERACONT�tACTOR4LI',_T� �� (n�oi"� LICENSE No. 097 Z BY l TITLE GL— DATE INS TIO ON ACTOR: HAWKINS INSULATION CO., INC. LICENSE No. 215-925 _TI DATE Owner DA'i'F July 18, 1978 1�`P COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footin s Windows -2o- A� 3rd Floor Stemwai I Siding To out -?D -7sr- Slab Roof Sheathing�Zo'7�' Water Pi in -10 ")F 21— Piers Roofing (9---107Sr- Sewer Garage Fdn. Vents -20- Fixtures Footings Stemwa I I Slab Carport Footings Garage Vents 4-Zri• Insulation Prov. for ph sitcallif y handica ed Conformance of ex. structure Water Htr. Heaters Appliances Gas Piping &Test �'�-V -7 A Temp. Gas Slab Final Sanitation Patio FIREP AC Final Footings Footing LEC ICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam . FIRE SPRINKLERS Motors Framing 3 -Lo Test Water Htr. Stucco Final Subpanels Mesh b'1D-�b� MECHANICAL Gird. Fault Prot. Scratch Brown Heating Cooling service Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final 715-C,115 Arlo- MOBILEHOME UTILITIES __________________ Elec_ Service Elec. Pedestal Water Piping Sewer Gas Piping MORILEHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping E ARKS OR CORRECTIONS DATE R M 0//7 Ir 0 0 L/Y')=t (NOTE: An entry must be made on this form each time you visit the job site.) t COUNTY OF-�31UTT'E — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT cN,c�cnaanu vca v, u,c vuunay u1 pullc W cMl l Ut/U11 1110 above-mentioned property for inspection purposes. X oat Sel re o/f errmtee or Agent Receipt No. / 77 / Q �_;,p White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY / Date 7 -Z,P- 7 B ding permit expires Date a dam— 7X BUILDING Owner r �J, SQ. FT. OCC. BUILDING VALUATION Mailing Address Tel jhon,, No. Contractor Mailing Address Fireplace Total Valuation Telephone No. Permit Fee p Building Address ,,/ _ 3 0`� Plan Checking Fee &/orPenalty Permit Fee s, o v � PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 00 Each Trap 1.50 y p Repair drainage or vent piping 1.50 A. P. o. ,367 - -.7 Water piping 1.50 , a Each gas water heater or vent 1.50 S O F s C. a ' Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 'p EQA Parking Plans Par I Declaration ^ P ce M 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 , pQ Bldg. Plans Rec'd Parcel AEeroyal p I on4,,Approval Lawn sprinkler system 2.00 NEW ® ADDITION ❑ UTILITIES ❑ OTHER ❑ Permit Fee $'122$ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Q Main service V OR LE 5.00 io°0°o AMP ORSL=SS Single Family IQ Duplex ❑ Mobil Home ❑ Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER 100 AMPP OR LESS O 25.00 Main service EA. ADD'L 100 AMP 1.00 NEW CONST. / DWELLING Y OR ADONIS.\ ACC. BLDGSO 22sgft 5 CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW RESID, � MULTI -OU LET S) NON-ESIBRANCH CIRCUIT 2.50ea NEW CONSTR POWER APPARATUS B NON.RESID. SINGLE OUTLET CIR. Ex. Occup{OUTLETS OR FIXT11RES g 025 Ex. QCCU FIXED APPLNS. OR P• OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 X Mobile Home Facilities 15.00 License No?�7 Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ '" $ s WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. jo�lI have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating L Od 00 Cooling x'00 CJ Ventilation Hood 2.00 r0 Permit Fee $ �� $ �( I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ �-- 0 TOTAL PERMIT FEE $ •� vC� ' cN,c�cnaanu vca v, u,c vuunay u1 pullc W cMl l Ut/U11 1110 above-mentioned property for inspection purposes. X oat Sel re o/f errmtee or Agent Receipt No. / 77 / Q �_;,p White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY / Date 7 -Z,P- 7 B ding permit expires Date a dam— 7X THERMALITO IRRIGATION DISTRICT 410 &-RAND AVENUE OROVILLE. CALIFORNIA 95965 TELEPHONE 533-0740 , CSA 26 SEWER SERVICE APPLICATION AND CONNECTION PERMIT Service Address: Owner's Name: ^ �� ; .�: •, .f �`" �- Date: * , . , . - . , Address: Acct. No: r A. P. No.: - Phone: '� �- ' /°-' --- No. Units: Applicant/Agent: Agents Proof: Address: Fees: Phone: Application $ Arrearage =�''`� 3 I 7r Preliminary Review By: -LDate: ''�' CSA 26 Remarks: SC -OR 1 st mo. S.C. Other Total Fees Collected By: -' Date: Field Review By: Date: Remarks: MONTHLY SERVICE CHARGES WILL COMMENCE AUTOMATICALLY UPON: ❑ Date of TID approval of completed building sewer (early connection). ❑ 30 days after date above, or on date of D.P.W. approval of completed building sewer, which ever comes first ("existing construction", prior to Mar. 5, 1974). 180 days after date above, or on date of D.P.W. approval of completed building sewer, which ever comes first ("new construction", after Mar. 5, 1974). DISTRIBUTION: WHITE - TID, YELLOW - APPLICANT, PINK - DPW, GOLDENROD - DPW to TID OWNER -RESIDENTIAL PLAN CHECKING GUIDE (S.F., DUPLEX, & MISC.-ONLY) Bldg. Permit # //,;/ 7 Y A.P. c�Zg --/4-'-G . 6 — f /a Z //,?3 7 1. . A. GENERAL Voning requirements (sideyards and parking). aluation. Signature by R.C.E. or Architect (if required). B. PLOT PLAN /Complete parcel size and dimensions. X Setbacks, sideyards, easements, etc. OVOther buildings or structures. Grading, fills,.drainage. C. FLO R! PLAN Romplete to scale plan with dimensions. equired windows for light and ventilation.(Sec. 1405). 114 /jam Required windows for second exit (Sec. 1404). Allowable glazing for energy requirements (20% max. per.State law). ' Human impact glass (Sec. 5406). required room sizes, ceiling heights (Sec..1407). F.C.I.'s in baths and exterior outlets (Sec. 210-8). Light fixtures, switches, receptacles, and exterior receptacles for maintenance of ,,91Zmechanical equipment. Locations of water heater, heating & cooling equipment, other electrical or gas equipment, and plumbing fixtures. Garage firewall, door size, and closer (Sec. 503(d)(4)). 1� 1 - 3'0" exterior -exit door (Sec. 3303d). `2 Fireplace location. Smoke detectors (Sec. 1413). OOV D. STRUCTURAL DETAILS Foundation plan complete enough to construct building. �2 Floor construction details complete enough to construct building. .3. Elevations and wall construction details complete enough to construct building. Roof construction details complete enough to construct building. TFireplace construction details and calcs if over one-story in height. .�Sufficient data and details to satisfy energy insulation requirements (State law). E. MISCELLANEOUS ITEMS TO LOOK OUT FOR CCX plywood on exposed locations and overhangs. Stairway details (Sec. 3305). Guardrail details (Sec..1716). rick or stone veneer (Chapter 30). xterior plaster - weep screeds (Sec. 4706 & 4708). Proper roof pitch for'roof covering.(Chapter 32). ZRafter ties or bearing ridge beam. rarage door or porch header sizes: .Adequate bracing. iving area over garage - complete 1 -hour separation walls and posts, etc. ll. Two (2) exits on three-story dwellings (Sec. 3302). required including supporting