Loading...
HomeMy WebLinkAbout030-212-006` � ' i .^ " . ft .. .. �. ..-- _ T,c ,. � , RESIDENTIAL 92-1878 P,E ;:.30-212-06 BIRD, Gayle'& Robert ' �58 Harlan- Ave , , Oroville contr : MH Center mh utilities ' t � 9a-i$os i OFFICE COPY �►� Address i GAS Meter By . Date IG ELECTRIC N Meter By Date, U_ JOB FINALED (Date)Z12*'?2—._ Signature Datewl,uard B-1 Date Card B-1 Date f f I Card B-1 Date Card B-1 Date MOBWf HOME INSTALLATION (Plans) OK except #'s Loof Zoping Requirements -Setbacks Easements IT.- Footings; Size -Spacing -Marriage Line as; MH Test-Demand-Valve—Connector L­r.—Elec ricity; MH Test -Crossovers -Breakers -Clearances Dra' ; MH Test -Fall -Flex Connector 0ar!MH Test -Regulator -Connector Wate nd Sewer Connected -C/O to Grade -HD Approval as and Electricity Tagged jq-lfxjis; Insp.-Sketch �Q Cert. of Occupancy Date and B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK } O=Not OKNot = Not Ready MOBILE M O B I L`E HOMES Date MOQXE HOME LITILITIES,(Plaps) OK except #'s Zo 'ng Requirementsietbacks-Easements . Soils ecial MH Supp rt Sketch e 'r; Location -Test -Fall /,O ncrete Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grn mp-Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. / /"Nat. or/ /"L"ft./ /"LPG 7 E Disconnect tility Clearance Datewl,uard B-1 Date Card B-1 Date f f I Card B-1 Date Card B-1 Date MOBWf HOME INSTALLATION (Plans) OK except #'s Loof Zoping Requirements -Setbacks Easements IT.- Footings; Size -Spacing -Marriage Line as; MH Test-Demand-Valve—Connector L­r.—Elec ricity; MH Test -Crossovers -Breakers -Clearances Dra' ; MH Test -Fall -Flex Connector 0ar!MH Test -Regulator -Connector Wate nd Sewer Connected -C/O to Grade -HD Approval as and Electricity Tagged jq-lfxjis; Insp.-Sketch �Q Cert. of Occupancy Date and B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ✓=OK O = Not OK = Not Applicable Not Ready RESIDENTIAL (; = Date UNDERFLOOR (Plans) OK except t1's 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except h's 16. Water Htr.: Vent -Access -Combustion Air -Baffle -- ------------------------------------------------ 17. Water Pipe; Test & Anchor -Nail Protection -------- ------------------------------------- -- 18. D.W.V.; Test -Fittings & Anchor -Nail Protection -------------- - --------------------- - - -19. Shower Pan; Test, First Floor -Tub Access - ----------------------- 20. Test Tub & Shower. Second Floor -Tub Access - ----------------------------- 21. Gas Pipe: Size & Anchors --------- ---------------------------------------------------- Date Card B-1 Date Card B-1 ------------------------ ------------------------ ----- ------------------ Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except h's 22.- Fixture -& Transformer Clearance -Ins. -Protection ------------------ ------------------------------------------------ -- 23. Elec. Receptacles Spacing -Lights & Switches at Doors -------------------------- --------------------------------------------- 24. Size Boxes & No. of Conductors -Stapled -------------------------------- 25. Romex Installed Close to Edge of Studs & C.J. -------- -------------------------------------------------------------- 26. Equip. Ground made up w/Mech. Fastners-Bond Gas & Water ------------------------ ------------------- 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI -------------------------- ------------------------------ 28. Subfeed Wire Size i ga. Cu or AI-A.C. Wire Size / ! ga. _ Cu or At -------------------------------- -------------------------- ---- 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No ---------- ------------------------------------------------ 30. Service -Riser Conductors & Ground -Main Disconnect --------------------------------------------------- _­­ ------------------------- 31. Equip Clearances Panels-Motors-Mech. Equip. - ----------------------------------------------- 32. Clothes Closet Light -Shower Light -Spa Light ------------- 33. Smoke Detector ---------------------------------------------------------------------------------- Date Card B-1 Date Card B-1 --- ------------------------------------ ---------------------------------------- Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except a's 34. A.C. Ducts Insulation & Support ------------------------------------------------------------------------------- 35. Vent Fan: Exhaust above insulation ----------------------------------------- -------------------------------------- 36. Condensate Drain & Overflow: Size & Grade --------- --------- ---------------------------------------- - - 37. Furnance-Vent: Access -Comb. Air -Return Air Vent -115 outlet -------------------------------------------------------------------------- 38 Attic Access & Platform if Furnance in Attic ------------------------------------------- ----------------------------------- Date Card -B-1 Date Card -B-1 Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except ft's 39. Sils. Proper Material & Anchors -------------............................... ............. --........ 40. Walls Studs -Nailing. Spacing & Bracing -Plates -Sound 41. Bearing Walls over Girders & Floor Nailing -- --- ---- - --------------------- - --- ----------------------- 42. ---------------------42. Draft Stop in Walls (rat proof) - ------------------------------------------------------------------------ ------------- 43.. Fire -Stops: Furred Ceilings -Stairs -Chases -Tub --- ------- -------------------------------------------------- 44. Headers & Beam -Size & Bearing Ingle & Duplex) Date FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access: Size & Romex Protection -Draft Stop -Ins, Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions _ 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits ------------ ----------------- __ 53. Stairs: Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers -- ----------- -- ------ ---- 55. Siding -Nailing Veneer 56. --Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access -------------------- ---- 57. Glazing Area -Glass Protection -Skylights -Plastic -------------- - 58. Shear Walls: Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows -------------- •-------------------------- Date Card B-1 Dale Card B-1 •------------------------------- - Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except h's -------------- 61. Ext. Steps -Door & Sidelight Protection -Landings ------------- -- - 62. Smoke Detector .------------------------------- 63. Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor -Ducts -Meeh. Protection --------------------- 64. -------- ---64. Bedroom Exiting --------------------------- 65. G F.I & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels ----------- ---------------------- 67. Stairs & Rails 68. Fireplace or Stove: Clearances -Hearth 69. Elec. Outlets at Wood Panel: Int. & Ext. 70. Kit.Fixt. & Appliance: Grnd.-Air Gap -Cooking Clearance - -- . ---------------------------- -- 71. Elec. Outlets & Receptacles at Kit. Counter -------------------------- ----- 72. Garage Fire Door: Swing -Landing -Closer -------------------------------------- 73. A.C. Duct in Garage -Damper --------------------- ----------------------------- 74. Wtr. Htr.: Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor -Meeh. Protection x.75. Plb. Elec. & Mech Equip. Listed for Location 76. Elec. Receptacles in Garage: (G.F.I.)-Romex Protection 7;. Insulation -Foam -Looked in Attic ❑ Yes ------------78.-Guard-Rails & Deck -Co nstruct ion -Post Caps ------------------------- - 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 80. Following instld.: Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No; Planters ❑Yes ❑ No ------------------------------------------ ----- 81. Stucco:Brown_Finish- ------ 82. A.C. Unit: Disconnect. Electrical, Plumbing 83. Vents Above Roof: Plbg.-Appliance-Fireplace.-Clearance to Openings ------- 84. Water Well: Disconnect, Electrical, Plumbing ----------- ------------------------ - 85. Exterior Elec. Trim: G.F.I. Receptacle -Underground - -- - - -- - - -- - - - - ----------------------------------- - 86. Ventilation Throughout House _ ------ -------------------------------------- 87. Glass Protection ----------------------- ----------------------- 88. Corrections from Previous Inspections -- ----------------------------------- 89. Gas Test -Meters Tagged; Gas -Electric ------ -------------------------------- ------------- 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates -------------------------------------------- -- --- Date Card B-1 Date Card B-1 --------------------------------------------- ----- -------- Date Card B-1 Date Card B-1 - Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center 06ve - Orovltle, Calliornla 95965 - Telephone: 916/538.7541 APPLICATION AND PERMIT ASSESSOR P RC L NU BER 30-212-006 ZONING A R BUILDING PERMIT / OWNER ROBERT & GAYLE BIRD TELEPHONE 868-1268 SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 15 EAST BIGGS HWY BIGGS 95917 CONTRACTOR'S NAME MOBILE HOME CENTER INC TELEPHONE Z1403 CONTRACTOR'S MAILING ADDRESS 1740 FEATHER RIVER BLVD OROVILLE 95965 Fireplace CONSTRUCTION LENDER NONE UNKNOWN Total Valuation is - LENDER'S MAILING ADDRESS Filing Fee $ — Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 20.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS 858 HARLAN AVE OROVILLE Permit fee $ PLUMBING PERMIT Filing Fee 15.00 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome[l Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home W I @ 15.00 45.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities 1X Installation❑ Other ❑ Describe work: MH U 1 REI-OOATFI _ rr— Permit Fee $ 60-00 Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200AORLESS 18.50 18.50 CONTRACTORS LICENSE LAW I declare under penaltyof perjury p j y (check one): 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Profession Code a d my license is in full/f�orc and effect. License No. Classification ci` ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason Main service 20GAT01000AI 37.50 NEW CONST. / DWELLING OCCUPM 3.54 sq.ft. OR ADDNS. 1 ACC. SLOGS. // NEW CONSTR. ULTI-OUTLET NON•RESID BRANCH CIRC ITS @ 5.00 PO ER APPARATUS IS SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES\\ 20 @ 75d Ex. Occup. OUTLETS ED AP(RESID IREA./ I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 15.00 Misc. Wiring 15.00 Permit Fee $ 48.50 — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 15.00 Heating Cooling g Hood 6.50 Ventilation EL permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree save, indemnify and keep harmless the County of Butte against all liabiliti s, judgments, costs, and expenses which may in any way accrue against a5d on in co que a of the granting of this permit. )( -' f%�. Date Signature of Applicant — Owner❑ Contractor ❑ Agent An OSHA permit is req red for excavations over 5'0" deep d demolition or construct- an ion of structures over 3/stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST TYPE TOTAL FEE $ 128.50 HAz OFEES IMP FLOOD COF PARCEL PD D ISSUE .I This permit is hereby issued under the applicable provi sions of the Butte Cou y Code and/or resolutions to do Work indica o or which fees have been paid. OF PUBLIC WORKS By Date L 1/ YZ, PERMIT EXPIRES Date 6-11--73 Receipt No. 116856 WNITC-O.P.W., 7ELLOW-A53[$SOR, PINK -INSPECTOR. GOLDENROD -APPLICANT nrn wvp T�V 's=Ar YiA'T f`�' !`i. ,'� M `'#.F /'tyC •Pr. ��....:HC7KWyl r'WMs, y� � �hk ✓N� COUNTY OF BUTTE„YPARTM>filF, PUBLIC W0 BUILDING BUILDING DIVISION a . r� 7 COUNTY CENTER DRIVE - OROV.ILLE, CALIFORNIA 95965 TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET / "O`/VNER �d�� IJCc. Q '•f. k �� -� ��%IP�No. (p Proposed Building Use r� Building Inspector C�'�J Date At time of permit application, I was advised the following data must be'submitted prior to permit processing and/or issuance: DATE RECEIVED B� 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 15. 16. 17. 18. ti19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. All items have been submitted. Plot plans, 3/4 sets, signed by preparer of plans . .......................... Complete plans, 3/4 sets, signed by preparer of plans . ...................... . Engineered plans and calcs, 3/4 sets, with wet signlu,re on plans . ............ . Hazardous Material Form . ............................................ Energy Design Compliance and supporting documentation . .................. Statement of Intent for Non -Heated and A/C Buildings . ...................... Engineered truss details and layout in duplicate (required prior to plan check). .... Mobilehome data and manufacturer's installation instructions, 2 sets. ........... Fees'of$ .......................................•... Impact fees as shown on attached schedule . ............................. . California Department of Forestry plan approval/fees. ........................ Flood elevation letter (100 year floo�j.f�y-C fornia Engineer. .. Heal epartment. ............ City of Chico plumbing permit . ......................................... Plot plan and business license approval from City of Biggs/Gridley. ............. Planning approval for (A) Use: (B) Parking: . ........ Contact Land Development about (A) Improvements (B) Drainage. Driveway permit (construction approval required prior to occupancy).�ig st Pre -inspection for required. o Buffspec�tuor (Date) Contractor's license information. (No., Name Style, Classification) . .............. Certificate of Workmans Compensation Insurance . .......................... Owner -Builder Verification (Given to owner , Mail to owner ) ............ Recorded copy of Agricultural Acknowledgement Statement . .................. Letter of signature authorization . ........................................ Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . Letter of intent on building use . ......................................... Mobilehome utility clearance . ......................................... . Documentation of legal access . ........................................ Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements. `4 Existing violations/expired permits . ....................................... Plancheck list . ..................................................... W en you issue the���i ocgps as follows: Mail to wner. ail to contractor. Telephone and hold for pickup at V` 0 office. Deliver with inspector. Other Parcel Creation �� /� Acreage Applicant Date > Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Polluti Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to,permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone -mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone -mail Counter by _ Date Plans checked by (31n% Date 2' Plans approved by _/�W Date Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works STATE OF CALIFORNIA )ss. . Butte ) COUNTY OF c o May 28, 1992 before me, the undersigned, a Notary Public in and for % co Robert L. Burt personally ' said State, personally appear ocxxxxxxxxxxxxxxxxxXXXXXXXXXX i U known to me R��pp�f�l�gibft7Dl�]�xibili��b�2fi�b di aX�dflXMy e�bDicfSbp�to be the person whose name is subscribed tothewithin instrumen , as � awitness thereto,who being by me duly sworn, deposed and said: W That he/sKe resides in OrOV 11 1 e , CA that he. §bK i� V . Bird was present and saw Gay 1 e $ personally c l3 known to him)KEWto be the same person(s) described in and who executed the within instrument, as a party(ies) thereto, sign, seal and deliver the same and that said party(ies) duly acknowledged N 00 in the presence of said affiant, that he/she/they executed the S' same, and that said affiant, thereupon at the party's(ies') request, 0 8 subscribed his/her name as a witness thereto. , i0 coo ficia I• WIA� WITNES y Signature Mic e e 1 e OFFICIAL SEAL • MICHELLE A. MILLER u. NOTARY PUBUC�nCA�LIFORNIA • • • • • • • • • • • • • • • • • • (This area for official notarial seal) END 0'F D00UAPENT_ _ _ Iaeturn to DPW AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT 9 2 - 2 3 9 8 FOR RESTDFNT?,AL DEVELOPMENT 'Section 26-8.1 of the Butte County Code requi.res this .acknowledgement be recorded _ prior to issuance of a building permit. �— V All. that real property situate in-t_he County of Butte, State of California, described follows: Do�� . LOT 24, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "OFFICIAL MAP OF HOWARD SUBDIVISION", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE.OF CALIFORNIA, JULY 26, 1927, IN BOOK 9 OF MAPS, AT PAGE 58. Date: S'Late of. ) County of ) i� F PROPE TY OWNERS: V, A'rd On this .the day of , 19 , before ine, SS. the undersigned Notary Public, personally appeared El Personally known to me. E] Proved Lo me on the basis Of satisfactory evidcnce. to be the person(s) whose name(s) subscribed to the within instrument and acknowledged OWL _ executed the same for the purposes therein contained. 1N WITNI-;tib, WHEREOF, I hereunto set my hand and official seal. Present A.P. No. Notary Public V G—VG44V b 1 Rec Fee 5.00 The property described herein is adjacent I Cash 5.00 Lo land or included within an area zoned Recorded I for agricultural purposes, and residents Official Records 1 of Lhis property may be subject to incon. County of I veniences or discomfort arising from the Butte I use of agricultural chemicals, including, Candace J. Grubbs I but not limited to herbicides, pesticides, Recorder I and fertilizers; and from the pursuit 2:28pm 28 -May -92 1 PUBL XX 1 of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which 1 occasionally generate dust, smoke, noise, and odor. Butte County has esLablished agr•ic•ul-- lural zones.which have as a priority use for productive agricultural purposes, and residollis within said zones and .on adjacent property should be prepared to accept such or discomform from normal, necessary farm operations.. All. that real property situate in-t_he County of Butte, State of California, described follows: Do�� . LOT 24, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "OFFICIAL MAP OF HOWARD SUBDIVISION", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE.OF CALIFORNIA, JULY 26, 1927, IN BOOK 9 OF MAPS, AT PAGE 58. Date: S'Late of. ) County of ) i� F PROPE TY OWNERS: V, A'rd On this .the day of , 19 , before ine, SS. the undersigned Notary Public, personally appeared El Personally known to me. E] Proved Lo me on the basis Of satisfactory evidcnce. to be the person(s) whose name(s) subscribed to the within instrument and acknowledged OWL _ executed the same for the purposes therein contained. 1N WITNI-;tib, WHEREOF, I hereunto set my hand and official seal. Present A.P. No. Notary Public h COU ' NTY. OF BUTTE DEPARTMENT OF PUBLIC WORKS' 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA-- (916)538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE 79 OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when cor'ie'ction`o*f work is completed. If you have any questions pertaining to this matter, or need additional explanation, Please contact this office immediately. is Date 6 Inspector FEV 11/91 MOBILEHOME INSTALLATION ACCEPTANCE COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS — 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA 95965 — TELEPHONE: (916) 538-7541 PERMIT N0. F�(5 5 - Address or location of mobilehome /16Lrk ,, I -JA— i% Owner's name n.�o.� V (ice )"It- � A — r Owner's address Insignia or hud number_ Manufacturer's name �n r�?� i�' 14- Aad i� Serial number of V.I.N.fislW/II !71-321"124 Year of manufacture Appro>orn'g Installs F IF THE MOBILEHOME IS MOVED OR RELOCATED, THE MOBILEHOME INSTALLATION - ACCEPTANCE SHALL BECOME INVALID. THIS FORM SHALL NOT BE USED WHEN THE 'MOBILEHOME IS INSTALLED ON A FOUNDATION SYSTEM. PP�a_a�a-vG ,, .1 . t _. t —White -Owner, Yellow-- Installer, Pink.- P.P.W. 11 .. . f. COUNTY, OF BUTTE - DEPARTMENT OF'PUBLfC WORKS County, Center Drive - Orovllle, Cftlifornia,95965 - Telephone: 916.'538-7541 APPLICATION AND PERMIT P RMI N0. —1805 i ASSESSOR PARCEL NUMBER 30-212-006 ZONING AR BUILDING PERAJIT OWNER GAYLE V. & ROBERT W. BIRD TELEPHONE 868-1268 SO.FT. OCC. BUILDING ATION OWNER'S MAILING ADDRESS 15 EAST BIGGS 194Y BIGGS 95917 CONTRACTOR'S NAME MOBILE HOME CENTER INC TELEPHONE 533-4403 CONTRACTOR'S MAILING ADDRESS 1740 FEATHER RIVER BLVD OROVILLE Fireplace CONSTRUCTION LENDER NONE UNKNOWN Total Valuation Is LENDER'S MAILING ADDRESS Filing Fee $ 15,00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 20.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty PRE INSP $ 20.00 BUILDING ADDRESS 858 HA LAN AVE OROVILLE 95965 Permit fee $ 55.00 PLUMBING PERMIT Filing Fee 15.00 Each Trap 1 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF ❑ Duplex[] Mobilehome❑X Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W @ 15.00 TYPE OF WORK New ❑ Addition D Remodel ❑ Utilities ❑ Installations Other ❑ Describe work: MH I Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200V OR LESS 00A OR LESS 18.50 Main service 200ATO1000A, 37.50 CONTRACTORS LICENSE LAW I decl re under penalty of perjury (check One): 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force ✓a]nd effect. License Ao. �L%d� Classification L'" / EJ as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) EJ 1, I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCCUP.g\ OR ADONS. ACC. BLDGS. // 3.6Q sq.ft. NEW CONSTR ULTI.OUTLET NON.R ESI D BRANCH CIRC ITS @ 5.00 POWER APPARATUS &) (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES 760 AO AR FIXED Ex. OCCUp. OUTTS ((RESID.IREA.1 I 3.00 Temporary service 15.00 Home Facilities 15.00 Misc. Wiring g 15.00 Permit Fee $ — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): The permit is for $100.00 (valuation) or less. !I have placed on file with the County of Butte Building Department `r a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 15.00 Heating Cooling g Hood 6.50 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agre save, indemnify and keep harmless the County of Butte against all liabil le ,judgment costs, and expenses which may in any way accrue against aid ounty in o se ence of the granting of this permit. X Datgj e Signature of Applicant e,?,- Owner ❑ Contractor ❑ Agent An OSHA permit i5Mioreo For excavations over 5'0" deep and emolirian or construct- ion of structures avetries in height. Mobile Home Installation Fee S 70.00 Ener Inspection Fee $ 9Y P occ CONST TYPE TOTAL FEE $ 125.00 rAz — DFEE IMP FLOOD CDF PARCEL PD HO Issu This permit is hereby issued under the sions of the Butte C my Code and/or for hich fees Work indicate RR B PU LIC PE IT EXPIR S Date applicable provi- resolutions to do i have been paid. WORKSDat Receipt No. 116821 105.00 116830 20.00 WNITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT j ..� • ti. �•' �` _)rt t.w ,.. , . 1i•, ,�X __ yy. }. 'Ir: r?�'v''.�-...7wa^'+'.: :,�a... wpE:Rk;t'FtO�"'7r iP9"T.,:Y �,u,,•,1Y':•. COUNTY OF BUTTE=•EPARTMENTyO �PIJBLIC WOI - BUILDING DIV SIO .. 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538- 541 PERMIT APPLICATION DATA SHEET OWNER- P-0 66 1- Proposed Proposed Building Use No. 2112 0C Building Inspector Date At•time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1, All items have been submitted . ................... f .................... 2. Plot plans, 3/4 sets, signed by preparer of plans . ........................... 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form . ........................................... . 6. Energy Design Compliance and suppo-rting documentation . ..... . ............. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... All 9. Mobilehome t�.and manufacturer's installation instructions, 2 sets. ........... 79� -Fees of $ mpact fees as shown on attached schedule. ... 5d,.`L d X e" ............. . California Department of Forestry plan approval/fees. ....................... . Wnitation od elevation letter (100 year flood) by California Engineer . ................. . and plot plan approval Health Department . ............. 15. City of Chico plumbing permit . ........................................ . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: . ........ 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 1 Driveway permit (co sltrV9ti n a va rec e r' cupancy). pre -Inspection requee - n. re11 -inspection for //``/f` // required. . to Building Inapeclor �� (Date) ,21. Contractor's license information. No., Name Style, Classification) . .............. lta Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner _). .......... . 24. Recorded copy of Agricultural Acknowledgement Statement . ................. . 25. Letter of signature authorization . ....................................... . 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . Letter of intent on building use. 28, obilehome utility clearance ........................................... G Documentation of legal access . ........................................ 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... 32.� Plan check list . ........... :......................................... 33. 34. When you issue the r�,)tRro ess as follows: Mailo ow r. Mail to contractor. Tel erhone 5 5` �� �id hold for pickup at /1 offic� Deliver with inspector. / Parcel Creation Acreage Applicant Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Polluti ii Date Copy of plans sent Health Dept. Fire Dept. Other Date The following data must be submitted ton it issuanc •Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Date By Contractor, designer, owner, was advised of above required data by _ phone —mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Plans checked by Iw Date 2 Plans approved by &,,JDate 6 Z Sets of plans on hold in File cabinet AP folder D I'O� Copy - Department of Public Works PRE -INSPECTION OWNER: �Q��L �� DATE -LOCATION: �S /�-7"/�/ �1/ 012 0A.P. # CONTRACTOR: %NI '} Ci�i�/ ZONINGi �J PRE -INSPECTION- FOR : DATE TO INSPECTOR PERMIT HISTORY: NONE AS FOLLOWS: TYPE OF OCCUPANCY FIELD - INFORMATION BUILDING USAGE: TENNANT: [� OCCUPIED F__j HAS ELECTRIC HAS GAS 0 HEATED -COOLED OTHER COMMENTS: " PERSON CONTACTED c- Q HAS SANITATION FACILITIES ACTIO. RECOMMENDED: ISSUE Q HOLD FOR 1+ OTHER: COUNTY OF BUTTE - DEPARTMENT OF PUBLIC.WORRS - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE; CALIFORNIA 95965 - TELEPHONE (916)5387541 OWNER 6112 A -P.. NO. PROPOSED BUILDING USE DATE o7 Z PEC. # _DATE REC School Distric Fees - �- (paid at District Office) �� �� 1 Sheriff Fees - (paid at Building Department) Residential X-$ i i V� /! 1' - to o� 9, � ..unit amt. - ommercial(per sq.ft.) I -X _$ s .ft. amt. _Ole Urban Area Fees 77 (paid at Building Department - Residential (per unit)- X _$ Un,4'mo Z� # units amt. Commerical(per sq.ft.) X =$, sq.ft. amt. 4. Recreation District Fees (paid at District Office) 5. Drainage District Fees. (Contact Land Development) 6. Other 7. Other At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. APPLICANT Vii' DATE S COUNTY OF BUTTE BUTTE COUNTY SCHOOLS'IMPACT FEE CERTIFICATION FORM BUILDING DEPT (One Form Per Buildings u JUN 17 12 _ :School Disteict---n" Building Department No.. A.P. Number 10 2,/ Z -2906 Jurisdiction... _ J " City. County Property Owner. /2 CC / ► //2 L� Property Location/Address —�3-S- - ___ i 9- Lail% A (/� _0 [L D 5 SUbdivison Lot No. Residential'Developmentl-Sq. Footage S RexUn• :� No. of Living I Addition (Group R) its •'`' • �PP �Gtc � n �S`� I vt I/ • ' '/ �/ ,�u�ld i n Commercial/In ustnal CVFf" � it �j r� Q Sq. Footage New Addition (Including Exterior ` Roofed Areas) Bui ding Departm t Representative >� . Date s re levee r,_ �.• District Identification No. (J School District c.ertifies that (Applicant) (Stree ddress) (Phone Number) (City) -----^--------------- — (State) -- (Zip,Code) ' has complied with the requirements of Resolution No. � by payment of $x'� representing School District Re resentative — square feet. Date . W Paid by Check Number _ _ Remark - Bank Number ------------ - — �, , � �l Paid by Cash I r• Ih � If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act.(CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) " feeform.wkl (4/92) I; N ^, This set of plans and snp%;; -:may ans MUST be kept on 'lh( sesl� csf elI limes cirri of is unlawftil to c9ke airy &,jr o S %`9' (511F��'r1 i +Pis on same withouf wriffen per issicn 'erom t he DonarRrnenf of Public Works, C =fy Of Bufie. c� (" n D. W w A a o �- 3 C r rq c (_. C--0 � CD z A l � CSA -0c: co 41 N m 3 Jy °N equipment.shall be as ShOWn � n A �A c� (" n r rq (_. C--0 � CD z A Location of structures & CSA -0c: co 41 N m �IvL y i ' (o C� 1 n, fU , _ .Fl AAM;-rizqIs ? ��E,ridrarrsiiip sfheil oA l;1 (:: .a e : rP?� •t'�3 ,'9i;�.? i'tY-;c? ; ''sir t: ;.J c+paclfi,::i� iMPlumbinq 01 coc"a. d mvqu BUTTE COUNTY BUILD I G DEPARTUENT A D 4. Location of structures & Jy °N equipment.shall be as ShOWn & clear of -ail easements. 1ACD sett es r' Sa ' F7?a m o F ?eoPro 7 w, G I oe PwUt0& I Y9 6t/AtLl ON 6A(Z-AaE ID 6: — CA F, .r nw, , 3 '66plI2470/u (wrrx i He- _ .. 6 A6c) 1 F 77f gZC-RILE Qp1U/N T „ IN THS !�'!OP'j10E tt4Yn£- G<Jl4CG MOBILE I- OINIE MUST I BEAR H.U.D. LABELS �IvL y i ' (o C� 1 n, fU , _ .Fl AAM;-rizqIs ? ��E,ridrarrsiiip sfheil oA l;1 (:: .a e : rP?� •t'�3 ,'9i;�.? i'tY-;c? ; ''sir t: ;.J c+paclfi,::i� iMPlumbinq 01 coc"a. d mvqu BUTTE COUNTY BUILD I G DEPARTUENT A D •. BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville CA PHONE: 538-7541 1. Owner's Name: A 2. Installer's Name: MOBILEHOME INSTALLATION SHEET F 3. Is the site currently under permit? Yes IN No (If yes, furnish permit number ) OR Is the site an existing site? . Yes No (If,yes, furnish two plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear.of all setbacks and easements? Yes No (If no, clarify �o f- / S��✓�2 5. What is the mobilehome electrical rating? --------------- v Ly Amps 6. What is the mobilehome site service rating? ------------- Amps 7. What is,the mobilehome site circuit breaker rating? ----- ✓L a U Amps 8. Is there any other electric load to be served by the mobilehome-site service? -------------------------------- Yes No (If yes, identify the load and size: (Load) (Amps) 9. What is the mobilehome site gas pipe s'ize?---------- 3 VK10- (in.) 10. What is the type of gas service? ----------------- Natural LPG 11. What is the gas pipe length from meter or tank to the mobilehome?--------------------------------------------- * 12. What is the mobilehome gas demand? ---------------------- �/ q- (BTU) *(This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) MU21LEROME SL'i"PORT DA`.CA �a 'o single than single wide L Mobilehome Mfr. d /n -L S F.r� furnish Setup Model No. Year (-Z`? Width Z. (ft.) Box Length5—L(ft-) Tagalong or Expando Sizeft. x ft, On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural set p sheets (if not on file with the County of Butte). FOOTINGS (check one) 1. Wood -pressure treated or foundation grade.2. Other (specify) SUPPORTS (check one) 1. Concrete block. 1:1 2. Other (specify) Pier Footing Sizes and'Locations s11+cLe-Wlue Main Beams Lines — — — — — — — — — — — — — — — � Ma1n Beanie — — — — — — — — -- — -.._Line 4 Tag or Triple Line 1 Line l Fiera: `- - ' Site -Min. ------------ SpavJng-Max.- '------- From Enda-Max.------- Line Z Piers: Size -Min. ------------ ,.x30 Spacing -Max. --------- V From Ends -Max.---.... I„1.iL Lino 1 Lo d Size-Mic.--------..-- x „ ' Location (Fiala Front) ne 4 Pltra: Size -Min ------------- ,k . Spa,ing-Mex.--------- From Inds -Max.------- „ Line ) Kooz Loads: Blse-Min.------.---- Location (From Front) Line 1 ODenig$a: Size -Min. ................ Each Side of Openings With Width Over -" ------ Line 7 Piece: (Under Bearing Wall Only) Sire-Min----­------------- Spacing-Max ................. -----Spacing-Max................ From Ends -Max .------------. „ fl E F - Size -Min ,-------- ^-_-.-.-. ,k Spacing -Max.- .............. From Ends -Max.------------- ,.x n ,k „ ux a ux U -a ILI--Y J 5 HK F V. 11 WAST ER BIEDPOOm GUEST BATBEDRGOV 2 BAYWOOD 184 13*- 4 . . ............... JtNG XITCHEN W=== - H j— M-1CRIC FAfJ -4 3REAKFAST LfVJNG ROOM NOOK 1-4 )IOOEL No. 1101 5IZE OWE Law P.L.F. IP.•�-� 2G��•5�• . ��.. • •ti-llALr 253 " B-NALf 253 • _J,.,L2q-" - - op U4! : !id = aul X71-211 g'_ (o 1 � 1 #r7 + j 111_4M i 171-2 �4SI- ty PIERS i FOOTINEi REQUIRENETITS is I a1. MULTI-WIDESH)E::_E HOMES REQUIRE AD)ETIONAL SU?PORTS AT DElAING POINTS ALONG 111 = CENTERLINE. THI: •SWPORTS (JACKS) MUST HINE A VIPACITY THA:E It ELL SUPPORT THE R]DQE BEAM LOADS. DIE CHAT IN.)I (. %TfS THE RIDGE BETH 0AOS IN Mums. E Txf 'Lo - 0 -TIONS FOR i (f SINGS d SUPPORTS AT OrARIXG POINTS ALONG -INE CENTER- LINE. 7HE SdZI: OF FOOTING;; ARE SHOI.B1 IN SQUARE INCHES FOR VARIOUS SC IL CONDITIOM . A 'SUPPORT PIER ':HOULD BE SEIECT:D FOR EACH LOCATION INDICATEO FOR YOUR WIEL. Tal: CAPACITf Cf TH._ SUPPORT PIER SHALL BE EQUAL TO OR GREATER DIA4 THE POUNI)S'REQUIREEI IN THE RlyGE BEAK LOAPi COLUMN OF THE (RUT. FOR ADD)TIOWL E'OOTING RI:QUIRENI:NTS REFER TO THE NONE SYSTa(S INC. HONE INSTALLI.TIE+N MANUAL. I 1 A B C D F F 6 b I - LOAD IN POUNDS c7,7-74. 2782 ¢7.22 SOIL 1000 +07 �1 ¢-i 832;_ 4-o 1 (o 950- COACITY 1500 FOOTING 2000 2��3r 4-1-7 2� - SQ. IN. 2500 157 -5-7,9 -3752-1 1 �o0 272 252- - NOTE: )THERE SHALL BE A 24" MAX. OVERHANG •IN WF ICH THE ADDITIONAL L13ADS WILL �E AIDED TO THE LOADING AT EACH ENDWALL THAT IS EFFECTED. A[QI11 HOMES WITH OpnO1VA1L2616 EXTERIOR WALLSMAY AFFECT THE LENGTH AND Wlp fH OF THE FOUNDATION PERIMETf It WALLS" CONSULT MANUFACTURER FOR MORE CLA81FiOAT1QN Of OvEMU. DIMENSl01VS I systems, Inc. ._ y clal m iw YTn ; SPAN CHART >: I ---- wrtE: X14 �0 Poo. --- sc-6a (S�{- --� f i. AP #x'30-2/2- - O4 OWNER PERMIT Z 8 74 MH UTIL.CLEARANCE DATE /22 1: .INSPECTOR j ELECTRIC GAS Support Struc. Compaction Test eq. !rvice Other Pipe YESI NO YES NO Lze Load Type Size Length i 1 t 1 1 I 1 f i s