Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
031-281-080
NOTES lJ RESIDENTIAL to13 iai-Oso• PERMIT NO. _ 05-0727 XIONG, YE 1435 7TH STREET, OROVILLE Cont: UNKNOWN ADD & REMODEL/SF f r 's SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER }. JOB FINALED (Date) Signature /2%— n CHECKED BY J=OK 0 = Not OK . = NotReadyable DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or / /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date 12. Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks -Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date 12. Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks -Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures -Panel boards- Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = Not OK - = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning -Setbacks -Easements -Flood -Slope Card B-1 Date Card B-1 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel- Bloc kouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors Date 7. Slab, Steel -Wrapped Date 8. Piers -Fireplace Ftg.-Steel Date 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 41. 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 42. 11. Water Pipe; Test -Anchors -Regulator -Service Test 43. 12. Electric Underground 44. 13. Plenums & Ducts; Clearance -Material -Support -Ins. 45. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 46. 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 72. Elec. Outlets at Wood Panel, Int. & Ext. Date 73. Card B-1 Date Card B-1 Date 74. Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Garage Fire Door; Swing -Landing -Closure 24. Fixture & Transformer Clearance -Ins. Protection A.C. Duct in Garage -Damper 25. Elec. Receptacles Spacing -Lights & Switches at Doors Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 26. Size Boxes & No. of Conductors Stapled Plb.; Elec. & Mech. Equip. Listed for Location 27. Romex Installed Close to Edge of Studs & C.J. Elec. Receptacles in Garage (FF.I.)-Romex Protection 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water Insulation -Foam -Looked in Attic 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI Guard Rails & Deck Construction -Post Caps 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth 31. Range Circle/ /qa Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral 0 Yes Q No Clearance Looked under Floor ❑ Yes 32. Service -Riser Conductors & Ground Main Disconnect Following Instld./Drive O Yes O No/Walks O Yes O No/Planters O Yes O No 33. Equip. Clearances Panels-Motors-Mech. Equip. Stucco Brown -Finish 34. Clothes Closet Light -Shower Light -Spa Light A.C. Unit Disconnect, Electrical -Plumbing 35. Smoke Detector Date FRAMING (Continued) Card B-1 Date Card B-1 Date Hangers -Post Caps -Anchors -Connectors Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40. Attic Access & Platform if Furnace in Attic Date 54. Card B-1 Date Card B-1 Date 55. Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 41. Sills Proper Materials & Anchors Siding -Nailing Veneer 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 43. Bearing Walls over Girders & Floor Nailing Glazing Area -Glass Protection -Skylights -Plastic 44. Draft Stop in Walls (rat proof) Shear Walls; Nailing -Bolts 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs Brace Interior/Exterior Wall Panels 46. Headers & Beams -Size & Bearing Insulation -Walls -Ceilings 63. Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties- Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (FF.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes _ 83. Following Instld./Drive O Yes O No/Walks O Yes O No/Planters O Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 PERMIT NO. BPO50727 PERMITS BECOME NULL AND VOID 1 YEAR FROM THE DATE OF ISSUANCE, OR IF WORK IS DONE IN VIOLATION OF ANY COUNTY OR STATE LAWS. LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 05/05/2005 APN: 031-281-080-000 the Business and Professions Code, and my license is in full force and effect. License Class : License Number: Site Address: 1435 7TH ST ORO Date: Contractor: Map Index: Description: garage conversion (252) cov deck (384) OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior Owner: XIONG, YE to its issuance, also requires the applicant for such permit to file a LEE, KENG signed statement that he or she is licensed pursuant to the provisions of 1435 7TH ST the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or OROVILLE, CA 95965-4431 she is exempt therefrom and the basis for the alleged exemption. Any 530_532_4979 violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): _ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Applicant: XIONG, YE Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does LEE, KENG such work himself or herself or through his or her own employees, 1435 7TH ST provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one OROVILLE; CA 95965-4431 . year of completion, the owner -builder will have the burden of 530-532-4979 proving that he or she did not build or improve for the purpose of sale.). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does Contractor: not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I am Exempt under Article 3 of the Business and Professions Code Date: S t7 Owner: License #: WORKERS' COMPEN19ATION DECLNRATION I hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Architect: is issued. ❑ I have and will maintain workers' compensation insurance, as Engineer: required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Total Square Ft: 384 S. F. Policy #: Valuation: $6,144.00 I certify that in the performance of the work for which this permit is Census Code: issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date:�i Applicant: WARNING: Faia to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal and one penalties hundred thousand dollars ($100,000), in to the addition cost of compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. T CONSTRUCTION LENDING AGENCY This per ' ' here(bpisssueed-ulnnderthe as pplicable-provislons-of the -Butte -Count Code dlor I hereby affirm that there is a construction lending agency for the Resl IUtl s t ork indica ed above for which fees have been paid. performance of the work for which this permit is issued (Sec 3097 Civ.) C /� Name: BY Date: CJ• OO Address: PERMIT EXPIRE D to ❑ I hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ , Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby 0uthorize representatives of Butte County to enter upon the above mentioned property for inspection purposes. Print Name: I ©Yl G1 Signature: Date: rl S 1 Owner ❑ Contractor 0 Agent for Owner ❑ Agent for Contractor BUTTE COUNTY DEPA TMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS 24 HOUR INSPECTION#: OROVI•LLE: (530) 538-7636 • CHICO: (530) 891-2834 OFFICE #: (530) 538-7541 A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds t,� o' **PLEASE PRINT CLEARLY* * �� �, OWNER Last Name first Name Address City State Zip s �� Phone X30 Z_ 7 Fax E-mail I ARCHITECT/ENGINEER I Name Address / City [r)" Vy St,' _ � . .7,^ Phonr-4-2,.1<--,7, w,,>4 I Fz Si PERMIT NO. 5•c�'� '91 BP BIN # LOCATION ONTRACTOR Name City Address z i���ds City Policy Number State Zip Phone LENDING AGENCY Fax E-mail Planner Lic. # Class I ARCHITECT/ENGINEER I Name Address / City [r)" Vy St,' _ � . .7,^ Phonr-4-2,.1<--,7, w,,>4 I Fz Si PERMIT NO. 5•c�'� '91 BP BIN # LOCATION API v-31 , a� l • o �U Property Address 3 S 7 i 5 me City Cross l z i���ds WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. Subdivision Name Map LENDING AGENCY Name ' � ' �I I 4^ Loan !'t/1 cin Address /_U 7 SIS/lEIGOW1 N MONN 3'I'I1102t0 `.La-I2I-LS t 4X APPLICAN7 __LZL0-90 Name Address � L1_ 7 �( City O ✓i//� statenq z i���ds Phon ✓ 3 �l �31 2 , 07 Fax E-mail) APPLICANT SIGNATURE X For office use only: Zoning Receipt #:�� �6 �•-� O^t Flood Zone o� SRA I Yes I No Occ. Type Const. Subdivision Name Map Book Page Lot # Planner Date Approved: V 080-18Z_ I £0 CION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be OVER FOR SUBMITTAL REQUIREMENTS L K:\FORMS\BUILDING FORMS\BldgApplSubRgmts.doc Page 1 of 2 REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Receiv� d\y: \ Amount: Bldg _ ^� X �_) / —// 3 � REV 7-27-04 SRA Receipt #:�� �6 �•-� O^t Sherif SMTP o� Other Date 1 o''� ti Total _ ^� X �_) / —// 3 � REV 7-27-04 SUBMITTAL & PERMIT REQUIREMENTS The following drawings and specifications must be submitted to the Building Division in order to apply for a " permit. INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ALL PLANS MUST BE LEGIBLE AND IN INK. 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. No graph paper! 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans (No graph paper!) OR Engineered plans, 3 or'4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 3. Engineered truss details and layouts in duplicate (if required). No faxes! ❑ 4. Energy compliance. design and supporting documentation in duplicate. (Note: Not required for additions to mobile or modular homes.) ❑ 5. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 6. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 7. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate (if required). ❑ 9. Site plan and business license approval from the City of Biggs. ❑ 10. Letter of intent for non-residential buildings. ❑ 11. Detached Accessory Building Form filled out by the owner (if required). ❑ 12. Hazardous Material Form (for Commercial Buildings only). ❑ 13. Sanitation and site plan approval from the Environmental Health Department. Remaining items needed to issue the permit. Additional items may be required after Plan Check and Planning review (May require additional plan review upon receipt of the following items.) ❑ 1. Agricultural Buffer clearance and site plan approval from the Ag Commissioner's office (if required). ❑ 2. Impact Fees. ❑ 3. California Department of Forestry plan approval (if required). ❑ 4. NPDES Form. ❑ 5: 'Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 6. Contractor's license information. (Number, Name Style, Classification). ❑ 7. Worker's Compensation Carrier and Policy Number. ❑ 8. Owner -Builder Verification (if required). ❑ 9. Letter of Signature authorization (if required). ❑ 10. Recorded copy of Agricultural Acknowledgment Statement. ❑ 11. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner (for 433A's). If you have questions or would like additional information regarding this process, contact a Permit Application Assistant at (530)538-7541. EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after date of application. In order to renew action on an application after expiration, a new application, plans and fees will be required. REQUEST FOR FEE REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made within two years from the date of fee payment on permits not issued, and two years from the date of permit issuance for permits issued; however, on issued permits refunds can only be made if no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. OVER FOR BUILDING PERMIT APPLICATION KAFORMS\BUILDING F0RMS\B1dgApp1SubRgmts.doc Page 2 of 2 REV 7-27-04 $ 285.95 $ 200.16 WILLDAN Fee $ 200.16 Copies Attached: Qty Chk Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other Butte County Department of Development Services guTr YVONNE CHRISTOPHER, DIRECTOR oo' %� /oo 7 County Center Drive o =�--f '. ,.' 0 0 Oroville,CA 95965 c-UN�y (530) 538.7601 Telephone (530) 538.7785 Facsimile O TO: WILLDAN ' FROM: Scott Rutherford (530) 538-7160 LO (ftuttecounty.net /) %%-,.SUBJECT: Plans Transmittal For Review Per Contract O z DATE: 3/21/2005 Applicant: Xion , Ye Permit No: 05-0727 Project Type: Cov Deck/Gar Conv APN: 031-281-080 100% 70% Plan Check Fees $ 285.95 $ 200.16 $ 285.95 $ 200.16 WILLDAN Fee $ 200.16 Copies Attached: Qty Chk Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: U� ASSESSOR PARCEL NUMBER l Proposed Building Use: 00 C -1D4_**% v � Permit Technician: Date: Items required in order to a O)y for a permit. All boxes MUST be checked OR marked NA in order b apply. 45 1. Site plans, 3 or sets, signed by the preparer of the plans. 697 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Letter from Engineer or Architect for truss design review. eff 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Installation manual, including marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate. ❑ 11. Letter of intent for non-residential buildings ❑ 12. Hazardous Material Form ❑ 13. Acknowledgement of building permit application without required clearances. ❑ 14. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) 15. Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable ❑ 16. Fire Sprinklers............................................................................................ ❑ 17. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 18. Soils Report and/or Engineered Foundation required ........................................... Di�*Eosion Control Plan Required.................................................................... es as shown on the attached Schedule of Fees Due Sheet ...........................❑ y of Chico Plumbing permit........................................................................ ❑ 22. Site plan and business license approval from the City of Biggs .............................. e 4 �California Department of Forestry pan approval ❑ paid. Sent by: Planning approval for (A) Use:(B)Parking: (C) Parcel Check:..G. ❑ 25. Contact Land Development about _ Improvements, _ Drainage ........................ f26. NPDES Form............................................................................................. ❑ 27. Encroachment Permit for driveway from the Public Works Dept ........................... ❑ 28. Contractor's license information. (Number, Name Style, Classification) ................... ❑ 29. Worker's Compensation Carrier and Policy Number .......................................... ❑ 30. Owner -Builder Verification ( _ Given to owner, _Mailed to owner) ..................... ❑ 31. Letter of Signature authorization.................................................................... ❑ 32. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 33. Existing violations and/or expired permits......................................................... ❑ 34. Deed Restriction.......................................................................................... ❑ 35. ❑ Legal description, ❑ M.H. Title, title search, registration or MCO ......................... ❑ 36. Other: ❑ 37. Other: When issued Telephone - t ' 1 and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: Date: 1 8 C2S 1. Index permit appliEati n for the above it numbered: Plan Check Letter 2. Additional items required Contractor, designer, owner, was advised of the above data by 0 phone, il, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: Date: Plans approved by: Date: Structural reviewed by- Date:Structural approved by: Date: i in Note transfer by: QqQjjn Date: 11_ Yellow: Building Division COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES — BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 TELEPHONE (530)538-7541 SCHEDULE OF RECEIPT OF FEES OWNER V A.P. # PROPROSED BUILDING USE li0y DATE ' O RECEIPT # DATE C. 1. BUILDING PERMIT FEES //3 5 --- Balance Due ..................... $ J --- Additional Fees Due........... $ Revised Plan Checking Fee.. $ 2. SCHOOL DISTRICT FEES (paid at School District Office) (form available after Plan Check) 3. SHERIFF FEES (paid at Building Division) Residential............ X $360.00 =$ Units Commercial (sq. ftg.)..... 4. URBAN AREA FEES Residential (per unit).. X $0.03 = $ Sq.Ftg. (paid at Building Division) X =$ # Units Amt. Commercial (Sq. Ftg.).... X = $ Sq. Fig. Amt. 5. RECREATION DISTRICT FEES (paid at Recreation District Office) (form available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK FEE $89.00 (paid at Building Division) 8. WATER TENDER FEES BATTALION # $200.00 (paid at Building Division) 9. NORTH CHICO SPECIFIC PLAN (paid at Building Division) Residential Zone X = $ Zone # Units Amt. Commercial (sq. ftg.) ......... X = $ 6"" � -# U I t Am Sq. Fig. t. THER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the plan checking process. APPLICANT aA DATE I X ®S Pursuant to Government Ae Section 660�you hereby notified that items, 2, 3, 4, 5, 6, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Division Yellow -Applicant Pink -Owner (rev. 2/2003) Q P,�TtrtENT °��v r rF°� I p , 1 1 C ' J ` �\ a .. a 5 ,tUc vYOR� Department C o u n t J. Michael Crump, Director Public f B u t Works LAND DEVELOPMENT DIVISION Storm Water Management Program 7 County Center Drive Oroville. CA 95965 (530) 538-7266 (FAX) 538-7171 National Pollutant Discharge Elimination System (NPDES) Phase li Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement LLESS THAN 1 ACRE1 Project Description: Project Location and/or Parcel Number: los -7 A 01-01/11le C gs,:71Gs By signing below, I, the project owner/owner's agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I, therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site build -outs of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project. that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions .provided by law. Signed: Title: &rd- 0 Date: Less than 1 Acre NPDES & SWPPP Compliance Certification Butte County Storm Water Management Program Revised 5/24/04 Serving WI LLDA�N Public April 19, 2005 Scott Rutherford Butte County Building Department 7 County Center Drive Oroville, CA 95965 v (530) 538-7169 (530) 538-2140 FAX \ SUBJECT: COUNTY OF BUTTE PLAN REVIEW APPROVAL 117 C Street Marysville, California 95901 530/749.2373 fax 530/749.2199 www.willdan.com Willdan Project No: 14353-1497 Jurisdiction Job No: 05-0727 Assessor's Parcel No: 031-281-080 Description: Cov Deck/Gar Conv Dear Mr. Rutherford: Willdan has completed a plan review of submitted plans and documents for the above referenced project and recommends your approval with the conditions noted on the 2"d page of this letter. The plans and documents provided for this review that have been found in compliance with the applicable codes are: ➢ Plans: Two (2) copies, sheets 1 through 2, dated 3/7/05 by Dick Miller ➢ Enerily Calculations: Two (2) copies, dated 3/14/05, by Donna Wallace The plans have been stamped with the Willdan approval stamp and dated the date of this letter. According to our previous letters relating to this project, the superseded plans and documents will be discarded within 10 days unless we receive other instructions. On the pages to follow is the identification of the codes and standards applicable to the project, a code analysis, conditions -of -approval and identification of any deferred submittals. A W I LLDAN Serving Public Agencies i APPLICABLE CODES Unless noted otherwise, all comments are based on requirements of the 2001 California Building Standards Code found in the California Code of Regulations, Title 24: • Part 2, known as the California Building Code and abbreviated herein as "CBC" • Part 3, known as the California Electrical Code and abbreviated herein as "CEC" • Part 4, known as the California Mechanical Code and abbreviated herein as "CMC" • Part 5, known as the California Plumbing Code and abbreviated herein as "CPC" Part 6, known as the California Energy Code, and Energy Commission Standards, and abbreviated herein as "CELS" CODE ANALYSIS ! 1. Our plan review revealed the following information regarding the occupancy designation, type of construction, and other pertinent features. This information is consistent with that shown on the plans and permit documentation. Specific Use Type of Occu anc Type of Construction ls` Floor Sprinklers Stories S Ft 2 nd Floor S Ft Total Sq Ft Dwelling R-3 V -N No 1 252 NA 252 Porch R-3 V -N No 1 384 NA 384 CONDITIONS OF APPROVAL 1. Approval is contingent upon the review, requirements and approval of other departments and/or agencies that have jurisdiction over this project. 2. Revisions and/or notes as red -lined on the plans. 3. There is no directional arrow indicated on the site plan. The building orientation will be verified as facing East by the Building Department as is indicated on the energy calculations. ' l - DEFERRED SUBMITTALS i Our plan review reveals no deferred submittals noted at this time. SPECIAL INSPECTION NEEDS {{� 1 Our plan review reveals no special inspection needs pursuant to CBC 1701. 0cey,ust R� i Guzman S. . J Plans Examiner Plan Check Engineer Ce: Alice Mefford, E-mail: amefford@buttecounty.net Ye Xiong, 1435 7h Street, Oroville, CA 959651 mage 2 of 2Count}' of Butte 1'enrut .Number 05-0)727 f Willdan Prgjcct Number 14353-1497 SITE PLAN REVIEW APPLICATION Date: S. 2 d 5— AP# d .31• Z 0 (� o Permit Number (if applicable) 0_ 672 Bin Number APPLICANT INFORMATION Owners Name: Owners Address: Telephone No.: Situs Address: Proposed Use: Parcel Size: �W /q35- 7-0 S, Residential ❑ New Single Family Residential ❑ Single Family Addition ❑ Mobile Home ❑ Residential Accessory ❑ Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ TemporaryTravel-Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other ❑ Septic ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if ne5ess�� Single Family Remodel ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well ❑ Agricultural Buffer Form ❑ Applicable ❑ N/A DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) Approved ❑ Conditionally Approved ❑ Resolve Problems Prior to Approval Sit an Stampe pproved By Date -0 S Page 1of5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: ❑ Snow Load Area: ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) ❑ SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: Q • Flood Panel No.: j0Ljj0L Index Date: 0'-- ❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance --------------------------------------------------------------------------------------------------------------- ❑ Detached Building Use Form- ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: d�- 2 (a,?) Applicable Building Setbacks: ❑ Setbacks drawn on site Plana ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Zoning Code Streets & Highways Fire Prevention Subdivision Map Front 120 ' Side Side Street Rear Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plana ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Applicable Development Fees: Standard Fees ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) Amount Formula * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By ❑ Deeds: Date of Creation: Legal Access Provided: Deed of Reference: Legal Access Required Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation:❑ No ❑ Yes Comments: ❑ Parcel Deemed to be legal ❑ No ❑ Yes ❑ No ❑ Yes ❑ Verify Legal Parcel ❑ Verify Legal Access ❑ Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 ❑ Subdivision ME/Parcel Map: Map Date of Recording: Lot: . Book: ❑ Use Permit/Minor Use Permit Permit Number: Date of Approval: Page: Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D; unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. 1 n Page 4 of 5 n 0 0 Summary of Specific Requirements: This information provided in this summary is based on the application information and on the best available data at the time of review. CALarrys\Building Permit Site Plan Reviewl.doc Page 5 of 5 Butte County Department of Development Services YVONNE CHRISTOPHER, DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538.7785 Facsimile ADMINISTRATION * BUILDING * GIS * PLANNING May 2, 2005 Ye Xiong 1435 Seventh Street Oroville, CA 95965 Subject: Building Permit 05-0727 (APN: 031-281-080); Parking Requirements Dear Ye: The Butte County Department of Development Services, Planning Division, has reviewed the submitted proposal. You are proposing to convert a garage to residential space. The Zoning Code requires two off street parking spaces for all single family residences. The garage is currently considered one parking space, and the drive way is the other parking space. You must indicate on the site plan where the other parking space will be located (replacement of the parking space located in the garage). Please indicate that you meet the minimum parking standards on you site plan; and return that to the Planning Division. Should you have any questions please feel free to call Chris Tolley, Assistant Planner, between the hours of 8:00 a.m. and 4:00 p.m. Monday through Friday at (530) 538-7603. (w) Interim Planning �, fo TYP. � - 1--- V G PLYWOOD CC Ut AeM L," _ CLIP: .r <--2•K IT' SPUR GTrZI i�Erz. nett+a +• 'TDP VIEW H RUP9RIL _ NOT 5 110 11111 - FbK CLMUTY. 2"ks(o DECKING -(ACI') 3l�' � BOLT i CLIP: .r <--2•K IT' SPUR GTrZI i�Erz. nett+a +• 'TDP VIEW H RUP9RIL _ NOT 5 110 11111 - FbK CLMUTY. 2"ks(o DECKING -(ACI') 3l�' � BOLT . GIRDERS � y'c ��here �� �a►�o � I W TA G PLYWOOD CC EWE diJ (O.cT,I.YJ �'h rt -,7 u Cp r oc MOBILE- II6MC J V `J ®R ®ELK r ' . FK141J 3 v� ® MAX. CLIP (Eft. DE . JIN11' POST 2"x l�' GrUARPRA1L ' i`IDE _! � '1eQ'• PRESSURE" ,./t.�,5� DECKIIJG' GIRDER I w10 PRECIIST 4"t P POST k -.fid—f.3 ' IEI ,aP504M PlAW)VAL 13RI�CING. TYPICAL RFSI D'rA17101— 6OUNTY OF BUTTE - DEPAnTMENT OF PUBLIC WORKS I if MIN. ` rdoTIN6 Tcounty Carder ®JBv® - ' Orov1J1®, Cpllrornla ve9®s , 'Yele(rhono: `i9I3--7�lal i G N is :�.m �2 ry �U�jJ �"P1 N.�.. Tom, ,� � F � tt r�9 i� �. y AMR, ROVED CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page l Project -Title CF -1R Ye Xiong Addi.ti.on Date..03./14/05 11:00:04 Project -Address........ 1435 7th Avenue ******* Thermolito, California *v6.01* Documentation Author... Donna Wallace ******* Building Permit 399 East 9th Avenue Plan Check -T Date Chico, CA 95926 530-893-4982 Field Check Date Climate Zone. ....... 11 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM CF -1R User#-MP0995 User- Run -Ye Xiong`, GENERAL INFORMATION Conditioned Floor Area..... 252 sf Building Type....... .... Single Family Detached Construction Type ......... Addition Alone Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 0.18 Number of Stories.......... 1 Floor Construction Type.... Slab On Grade KE(__�`EIVE Glazing Percentage........'. 11.5 % of floor area Average Glazing U -factor... 0.81 Btu/hr-sf-F Average Glazing SHGC....... 0.7 MAR 2 3 2005 Average Ceiling Height .... 8 ft BUILDING SHELL INSULATION WILLDAN Component Frame Cavity Sheathing Total AssemblyL`'�C Type Type R -value R -value R -value U -factor Location/Comments Wall Wood R-13 R-0 R-13 0.088 Typical Roof Wood R-11 R-19 R-30 0 . 031 Typic] S1abEdge n/a R-0 R-n/a F2=0.760 to vu S1abEdge n/a R-0 R -n a / F2=0.510 to ravels ace FENESTRATION APR 19 2005 . Area U- Interior Exterior hang/ Orientation (sf) Factor SHGC Shading Shading Fins Window Front (E) 20.0 0.600 0.650 Standard -Standard Yes Window Left (S) 9.0- 1.280 0.800 Standard Standard None SLAB SURFACES Area Slab Type (sf) Standard Slab 252 BUTT LE; BUILDING U1V1SRC1'1ty� APPROVED. CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF-1R Project Title.......... Ye Xiong Addition Date..03/14/05 11:00:04 MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program-FORM CF-1R User##-MP0995 User- Run-Ye Xiong HVAC SYSTEMS Refrigerant Tested ACOA Equipment Minimum Charge and Duct Duct Duct Manual Thermostat Type Efficiency Airflow Location R-value Leakage D Type YP Furnace 0.630 AFUE n/a None R-n a n/a NoCooling 10.00 SEER No Attic / / n/a Setback R-4.2 No No Setback SPECIAL FEATURES AND MODELING ASSUMPTIONS ***Items in this section should be documented on the plans, *** ***.installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building does not have a cooling system installed. REMARKS Fenestration was assigned CEC default U-factors and default SHGC-values. The HVAC system and water heater are existing. ------=I CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF-1R Project Title.......... Ye Xiong Addition Date..03/14/05 11:00:04 MICROPAS6 v6.01 File-XI ONG Wth-CTZ11S92 Program-FORM CF-1R User#-MP0995 User- Run-Ye Xiong COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title-24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any "shading feature that is varied is indicated in the Special Features Modeling Assumptions section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name .. Ye Xiong Name.... Donna Wallace Company. Company. Address. 1435 7th Avenue Address. 399 East 9th Avenue Thermolito, California Chico, CA 95926 Phone... 530-532-4979 License. Phone... 530-893-4982 " Signed.. T Signed. ��_ 3///s dated Td—a ENFORCEMENT AGENCY Name. Title .. Agency.. Phone . Signed.. date. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Pagel MF -1R t Title Ye Xiong Addition Date..03/14/05 11:00:04 Projec ... ..... ******* Project Address........ 1435 7th Avenue Thermolito, California *v6.01* Documentation Author... Donna Wallace ******* Building Permit 399 East 9th Avenue Plan Check Date Chico, CA 95926 530-893-4982 Field Check Date Climate Zone....... 11 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM MF -1R User#-MP0995 User- Run -Ye Xiong" Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permitdocuments, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a) Minimum R-19 ceiling insulation. R-30 150(b): Loose fill insulation manufacturer's labeled R -Value. N/A *150(c): Minimum R-13 'wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply_ R-13 to exterior mass walls). A floor insulation in framed floors. N/A *150(d): Minimum R-13 raise 150(1): Slab edge insulation - water absorption rate no _greater than 0.3% water vapor transmission rate no greater than 2.0 N/A perm/inch. 118: Insulation specified or installed meets insulation quality FIBERGLASS BATTS standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. 2. Fenestration products (except field fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification. 3. Exterior doors and windows weatherstripped; all joints BY CONTRACTOR and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 N/A only. 150(f): Special infiltration barrier installed to comply with N/A Sec. 151 meets Commission quality standards. 1`50(6): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. N/A ��1161!!W�[�4111�b'NpY�BYI'YwaR��x. IIII _ MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Propect Title .... . ___ Ye Xinna Arbilt;nn nate n�/14/nr, ii -nn -n4 MICROPAS6 x6.01 File-XIONG Wth-CTZ11S92 Program -FORM MF -1R User#-MP0995 User- Run -Ye Xiong -SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES Design- Enforce- er Ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Commission. N/A 150(h); Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA. ATTACHED 150(1): Setback thermostat on all applicable heating and/or cooling systems N/A 150(j): Pipe and Tank insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R-12 or greater. 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, onrecirculating'systems, insulated (R-4 or greater). 3. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 combined internal/external insulation. 4. All buried or exposed piping insulated in recirculating sections of hot water system. 5. Cooling system piping below 55 degrees insulated. 6. Piping insulated between heating source and indirect hot water tank. N/A *150 (m) : Ducts and Fans 1. All ducts and plenums installed, sealed and in- sulated, to meet the requirements of the 1998 CMC sectons 601, 603, and 604, and standard 6-3; ducts insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, aerosol sealant, or other duct -closure system that meets the applicable requirements of UL181, UL181A, or UL181B. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used. Building cavities shall not be used for conveying conditioned air. Joints and seams of duct, systems and - their components shall not be sealed with cloth back rubber addhesive duct tapes unless such tape is used in combination with mastic and drawbands. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. N/A 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System ,is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spas 3. Pool system has directional inlets and a circulation pump time switch. N/A 115: Gas-fired central furnaces, pool heaters, spa heaters or MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 3 MF -1R Project Title.......... Ye Xiong Addition Date..03/14/05 11:00:04 MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM MF -1R User##-MP0995 User- Run -Ye Xiong household cooking appliances have no continuously burning Pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr)' . N/A LIGHTING MEASURES Design- Enforce- 150(k)l: Luminaires for general lighting in kitchens shall er have lamps with an ment efficacy of 40 lumens/watt or greater for general lighting in. kitchens. This general lighting shall be controlled by a'switch on a readily accessible lighting control panel at an entrance to the kitchen. N/A 150(k)2: Rooms with a shower or bathtub must have either at least one luminaire with lamps with an efficacy of 40- lumens/watt or greater switched at the entrance to the room or one of the alternatives to this requirement allowed in Sec. 150(k)2.; and recessed ceiling fixtures are IC (insulation cover) approved. N/A COMPUTER METHOD SUMMARY Page 1 C -2R 05 11:00:04 Project TitDate..03/14/05 Ye Xiong Addition / / Project Address........ 1435 7th Avenue ******* Thermolito, California *v6.01* Documentation Author... Donna Wallace ******* 399 East 9th Avenue Chico, CA 95926 530-893-4982 Climate Zone........... 11 C -14 �,- -- Nrc hnrl MTCROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User- Run -Ye Xiong MICROPAS6 ENERGY USE Building Permit Plan Chec Date Field Check/ Date MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User- Run -Ye Xiong MICROPAS6 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 32.39 24.15 8.24 Space Cooling.......... 13.39 21.11 -7.72 1 45 78 45 26 0.52 Tota +APP11-10t4 *** Water Heating not calculated GENERAL INFORMATION Conditioned Floor Area..... 252 sf Building Type. ....... ... Single Family Detached Construction Type,......... Addition Alone Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 0.18 Number of Building Stories. 1 Weather Data Type.......... ReducedYear Floor Construction Type.... Slab On Grade Number of Building Zones... 1 Conditioned Volume......... 2016 cf Slab -On -Grade Area ........ 252 sf Glazing Percentage....... 11.5 % of floor area Average Glazing U -factor... 0.81 Btu/hr-sf-F Average Glazing SHGC....... 0.7 Average Ceiling Height. 8 ft BUILDING ZONE INFORMATION Floor # of Vent Vent Air Area Volume Dwell Cond Thermostat Height Area Leakage Zone Type (sf) (cf) Units itioned Type (ft) (sf) Credit HOUSE Residence 252 2016 0.18 Yes Setback 2.O Standard No COMPUTER METHOD SUMMARY .Page 2 C -2R Project Title.......... Ye Xiong Addition Date..03/14/05 11:00:04 MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -FORM C -2R User#-MP0995 User- Run -Ye Xiong OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) factor R-val Azm Tilt Gains Reference Comments HOUSE - New 1 Wall 76 0.088 13 90 90 Yes W.13.2X4.16 Typical 1Wall 159 0.088 13 180 90 Yes W.13.2X4.16 3 Wall 32 0.088 13 0 90 Yes W.13 2X4.16 4 Roof 252 0.031 30 n/a 0 Yes R.30.2X4.24 Typical PERIMETER LOSSES Length F2 Insul Solar Surface (ft) Factor R-val Gains Location/Comments HOUSE - New 5 SlabEdge 37 0.760 R-0 No to Outside 6 SlabEdge 29 0.510 R-0 No to Crawl space FENESTRATION SURFACES Area U- Act Exterior Shade Interior Shade Orientation (sf) factor SHGC Azm Tilt Type/SHGC Type/SHGC HOUSE - New 1 Window Front (E) 20.0 0.600 0.650 90 90 Standard/0.76 Standard/0.68 2 Window Left (S), 9.0 1.280 0.800 180 90 Standard/0.76 Standard/0.68 OVERHANGS AND SIDE FINS Window= Overhang 'Left 'Fin Right Fin— Area Left Rght Surface (sf) Wdth Hgth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE New 1 Window 20.0 n/a 4.0 2.0 0.7 n/a n/a n/a n/a n/a n/a n/a n/a SLAB SURFACES Area Slab Type (sf) HOUSE Standard Slab 252 COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... Ye Xiong,Addition Date..03/14/05 11:00:04 i MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program-FORM C-2R User#-MP0995 User- Run-Ye Xiong HVAC SYSTEMS Refrigerant Tested ACCA System Minimum Charge and Duct Duct Duct Manual Duct Type -Efficiency Airflow Location R-value Leakage D Eff HOUSE Furnace 0.630 AFUE n/a None R-n/a n/a n/a 1.000 NoCooling 10.00 SEER No Attic R-4.2 No No 0.645 SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** ** verified during plan check and field inspection. *** This building does not have a cooling system installed. REMARKS Fenestration was assigned CEC default U-factors and default SHGC-values. The HVAC system and water heater are existing. �I I�� HVAC SIZING Page 1 HVAC Project Title.......... Ye Xiong Addition Date..03/14/05 11:00:04 Prot Add 1435 7th A ******* �ec ress. venue Thermolito, California *v6.01* Documentation Author... Donna Wallace ******* Building Permit 399 East 9th Avenue Plan Check Date Chico, CA 95926 530-893-4982 Field Check Date Climate Zone....... ... 11 Compliance Method...... MICROPAS6 v6.01 for 2001 Standards by Enercomp, Inc. MICROPAS6 v6.01 File-XIONG Wth-CTZ11S92 Program -HVAC SIZING User#-MP0995 User- Run -Ye Xiong GENERAL INFORMATION Floor Area.......... ..... 252 sf Volume.. .. .......... 2016 cf Front Orientation.......... Front Facing 90 deg (E) Sizing Location............ OROVILLE RS Latitude.. ................ 39.5 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 104 F Summer Inside Design....... 78 F Summer Range.... ....... 37 F Interior Shading Used...... No Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction....... 0.20 HEATING AND COOLING LOAD SUMMARY Heating Cooling Description (Btuh) (Btuh) Opaque Conduction and Solar...... 2971 930 Glazing Conduction ............... 941 612 Glazing Solar. ................... n/a 1204 Infiltration: .... ... ... 1147 471 Internal Gain .................... n/a 378 Ducts. .. ....... .......... 0 359 Sensible Load.................... 5059 3954 Latent Load........... ......... n/a 791 Minimum Total Load 4744 5059 Note: The loads shown -are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. s2` 'iu i 7N AU Y i i S4 x80 PRINTED ON NO. 10