Loading...
HomeMy WebLinkAbout035-071-015GENERAL NOTES 9. The contractor shall have all,glass (inside and out), plumbing fixtures, 1. The Contractor shall verify all dimensions and details prior, to mirrors, vinyl floors, etc. cleaned by professional cleaners and shall construction and notify the Architect of any discrepancies. j be responsible for any damage or disfigurement therefrom. 2. Contractor agrees that he shall assume sole and complete responsibility 10. Hose bibbs shall have approved nonremovable backflow prevention devices'. for job site conditions during the course of construction -of this project, including safety of all persons and property; that.this it. water heaters shall be anchored to resist horizontal movement due to requirement shall apply continuously and not be limited to normal J earthquakes with 2" wide 16ga. G.I. straps within 6" of top of tank working hours; and that the contractor shall defend, indemnify, and a,nd lag screwed into adjacent wood stud walls. hold the owner and architect harmless from any and all liability, real or alleged, 10 connection with the performance of work on this 12.. rronches or excavations Vor more In depth Into which a person Is project, excepting for liability arising from the sole negligence of trequired to descend, must obtaln.a permit from Cal/Osha prior to the the owner or architect. Contractor further agrees that he shall not- Lssuance of a.building or encroachment permit. HSC 17922.5 -deviate from these drawings and details In any manner without first obtaining written approval from the owner. Clarifications as to the 13.. Caulk and seal under perimeter wall plates at wood stud walls at ttt meaning or intent of the drawings and details shall be directed to the building. All open Joints, penetrations, and other openings In the. architect for direction prior to proceeding with the work effected, building envelope shall be sealed, caulked, gasketed, or weatherstripp'ed f' to limit air leakage. 3. All work shall be done in complete compliance with current governing codes, rules, regulations, and standards of the authority having 14. Exterior doors shall be provided with a seal, astragal, or baffle at the Jurisdiction such as the Uniform Building Code (U.B.C. 19191 Edition), head and -sill. Exter4or doors mounted between Jambs shall have a the Mechanical Code National Electrical Code, and the county or continuous seal or baffle at each Jamb. city building department.4he 15. Class In doors and sidelights within Oft. of doors, shall have safety 4. The contractor shall obtain and pay for all permits and Inspections glazing. as required. d .6. Exhaust fans shall have back draft dampers. 5. All materials and workmanship shall be in accordance :with recognized good quality and practices, free from hammer marks and other injuries, rical contractor shall provide a 1.20 volt receptacle on a and shall be adequately protected untill the completion 'of the Job. disconnec. (01 feet of mechanical equipment. A permanent Interior trim corners shall be mitered, no end grain showing, all nail c e electrical outlet and lighting ed by a switch located heads set, trims to be true and straight. alt the passageway opening shall be provided at or n ted 2t furnaces. 6. The contractor shall protect the work in progress, adjacent property, and materials delivered to the job. 1,8. Fire stops shall be installed in concealed spaces of stud walls and partitions, in,71uding furred spaces, at the ceiling and floor levels 7. Amounts for extras and credits for changes made in terms of the contract aind at 110' intervals along the height of the wall, and at Interconne.c- must be submitted to the owner in writing and signed by him before tinnz between ccrcealed vertical and horizontal spaces such as Qcci-ir-, proceeding with the work to insure adjustment in the contract price at at soffits, dropped ceilings and cove ceilings. the completion of the work. 19. Fire stops of noncombustible material shall be installed In openings 8. The contractor shall leave the building clean and the site free from all airound vents, pipes, ducts, chimneys, and similar openings which afford construction . debris, a, passage for fire at ceiling and floor level:. LA -V4414 --i IT Ty � ;--177__ _,444 T _T_ 12 A1 Li C:>f VN r;V 171 C J -7 4 I.w rA I? tv 46-74 76,4 F T V i"111 e:� A- 00 eV -7 64S 1-1 'Zz L r i. 4— rr, `7 L11 r i x 4 x e� q4I LF-F', ATTA e,- H tin4i 61 Ji7 X - vruTr �Av,5,reko wi,,s! .5AMr-- 1�; WX-E-5 IF14 pe - P -V A, �4. *A 4 60 12 r 4N 4� x i N % 2v M101 _77 7_7:!7-,- __7-_-_--_.. r4 (m) Ve 4x 4 TUVS No. 2 7 _UW �A ,4411 4 L NEAA veef., 1 en FT J T !7777: 77-7 1! -7f ly Vp it Department Of W1�4FTIIIL]IeA FVLILC:�5i; Code Enforcement -*1 'i I i Approved City Of ormfille Datb 34J -q5 BY�-EP- "OFFICE COPY'