HomeMy WebLinkAbout035-071-015GENERAL NOTES
9.
The contractor shall have all,glass (inside and out), plumbing fixtures,
1.
The Contractor shall verify all dimensions and details prior, to
mirrors, vinyl floors, etc. cleaned by professional cleaners and shall
construction and notify the Architect of any discrepancies. j
be responsible for any damage or disfigurement therefrom.
2.
Contractor agrees that he shall assume sole and complete responsibility
10.
Hose bibbs shall have approved nonremovable backflow prevention devices'.
for job site conditions during the course of construction -of this
project, including safety of all persons and property; that.this
it.
water heaters shall be anchored to resist horizontal movement due to
requirement shall apply continuously and not be limited to normal J
earthquakes with 2" wide 16ga. G.I. straps within 6" of top of tank
working hours; and that the contractor shall defend, indemnify, and
a,nd lag screwed into adjacent wood stud walls.
hold the owner and architect harmless from any and all liability,
real or alleged, 10 connection with the performance of work on this
12..
rronches or excavations Vor more In depth Into which a person Is
project, excepting for liability arising from the sole negligence of
trequired to descend, must obtaln.a permit from Cal/Osha prior to the
the owner or architect. Contractor further agrees that he shall not-
Lssuance of a.building or encroachment permit. HSC 17922.5
-deviate from these drawings and details In any manner without first
obtaining written approval from the owner. Clarifications as to the
13..
Caulk and seal under perimeter wall plates at wood stud walls at
ttt
meaning or intent of the drawings and details shall be directed to the
building. All open Joints, penetrations, and other openings In the.
architect for direction prior to proceeding with the work effected,
building envelope shall be sealed, caulked, gasketed, or weatherstripp'ed
f'
to limit air leakage.
3.
All work shall be done in complete compliance with current governing
codes, rules, regulations, and standards of the authority having
14.
Exterior doors shall be provided with a seal, astragal, or baffle at the
Jurisdiction such as the Uniform Building Code (U.B.C. 19191 Edition),
head and -sill. Exter4or doors mounted between Jambs shall have a
the Mechanical Code National Electrical Code, and the county or
continuous seal or baffle at each Jamb.
city building department.4he
15.
Class In doors and sidelights within Oft. of doors, shall have safety
4.
The contractor shall obtain and pay for all permits and Inspections
glazing.
as required.
d
.6.
Exhaust fans shall have back draft dampers.
5.
All materials and workmanship shall be in accordance :with recognized
good quality and practices, free from hammer marks and other injuries,
rical contractor shall provide a 1.20 volt receptacle on a
and shall be adequately protected untill the completion 'of the Job.
disconnec. (01 feet of mechanical equipment. A permanent
Interior trim corners shall be mitered, no end grain showing, all nail
c e
electrical outlet and lighting ed by a switch located
heads set, trims to be true and straight.
alt the passageway opening shall be provided at or n ted
2t
furnaces.
6.
The contractor shall protect the work in progress, adjacent property,
and materials delivered to the job.
1,8.
Fire stops shall be installed in concealed spaces of stud walls and
partitions, in,71uding furred spaces, at the ceiling and floor levels
7.
Amounts for extras and credits for changes made in terms of the contract
aind at 110' intervals along the height of the wall, and at Interconne.c-
must be submitted to the owner in writing and signed by him before
tinnz between ccrcealed vertical and horizontal spaces such as Qcci-ir-,
proceeding with the work to insure adjustment in the contract price at
at soffits, dropped ceilings and cove ceilings.
the completion of the work.
19.
Fire stops of noncombustible material shall be installed In openings
8.
The contractor shall leave the building clean and the site free from all
airound vents, pipes, ducts, chimneys, and similar openings which afford
construction . debris,
a, passage for fire at ceiling and floor level:.
LA -V4414 --i
IT Ty
� ;--177__ _,444
T
_T_
12
A1
Li C:>f
VN
r;V 171 C
J
-7
4 I.w
rA I? tv 46-74
76,4 F T
V i"111 e:�
A-
00
eV
-7 64S
1-1
'Zz
L r
i.
4—
rr,
`7
L11 r
i x 4 x
e� q4I LF-F', ATTA e,- H
tin4i
61
Ji7 X -
vruTr
�Av,5,reko wi,,s! .5AMr-- 1�; WX-E-5
IF14 pe -
P -V
A,
�4.
*A 4 60 12
r
4N
4�
x
i
N
%
2v
M101
_77 7_7:!7-,- __7-_-_--_..
r4
(m)
Ve
4x 4 TUVS No. 2
7
_UW
�A
,4411
4
L
NEAA veef.,
1 en
FT
J
T
!7777: 77-7 1!
-7f ly
Vp it
Department Of
W1�4FTIIIL]IeA FVLILC:�5i; Code Enforcement
-*1 'i I i Approved
City Of ormfille
Datb 34J -q5 BY�-EP-
"OFFICE COPY'