Loading...
HomeMy WebLinkAbout035-214-002AP 35-214-2 GEORGE 4529 Baggett R ovill Permit0- 29'88=74P;E' - `j-Cti � (util., MH) ; O�,u�tr. 35-214-2 �Tayne Anderton 4529 Marysville-Bagget Rd., Orovilh contr: Acro-Lume, Oroville Permit ## 79-76B(erect new awning/m)'# IF 1y 3 5 - 214- 2 . �---- --: GEORGE JACOB S � � 4529 Bagget Rd, OO�roville)�' " Contr: Lincoln Village MH, Orofj { Permit #6874-79MHI (existing' site) .ssued. -------- ----------- ! -_ ■ELEC. GAS . e z - cf-7 9 SUP—PC R T STRUC. /If0 COMPACTION TEST /U ` � �r 1q jgC)35-214-2 Contr: Lincoln Village MH, Oro Permit##7303-79P,E(inst. gas line & de from meter to pedestal) MH 35-214-02, WAYNE ANDERSON �,� 4529 Baggett-Mysv RdOrovillle Contr:Superior MH, Mysv ✓/J/ / Permit#365-87MHI(exlsting sits) Issued 1.1 BUTTE COUNTY INTER -DEPARTMENTAL CORRESPONDENCE DELIVER TO LAST PERSON NAMED DATE NAME DEPT. I DATE NAME DEPT. - II a t 0 o PERMIT NO. 365-87NHI xist site) PERMIT EXPIRES• OWNER WAYNE ANDERSON CONTR. Superior MH, MysV ASSESSOR PARCEL 35-214-02 LOCATION 4529 Baggett Mysv Rd, Oroville OFFICE Copy Address Temp. Power S Called P GA Meter t L CT Date L.ELECTRIC Temp. Elec. Me te r. 13 y Date Called Temp. Gas Service Called PG&E JOB FINALED (Date) I J OK . . D = Not OK - = Not Applicable = Not Ready RESIDENTIAL'(Single and Duplex) Date UNDERFLOOR Plans OK except#'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits _ 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection - 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 52. _ Siding -Nailing -Veneer 6.__Ste_mwalls; Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access_ _ 7. 8. Piers -Fireplace Fig. -Steel D.W.V.:Fall-Fittings-Test-2 way C/O -Sewer Test 54. _ Glazing Area -Glass Protection -Skylights -Plastic 55. Shear Walls; Nailing -Bolts 9. Gas Pipe: Size -Anchors 10. Water Pipe: Test -Anchors -Regulator -Service Test - 11. Electric; Underground 12. Plenums & D_ucts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI DateCard-BI Date Card -BI Date Date Card -BI Date d' FINAL (Plans) OK except #'s 56. Ext. Steps -Door & Sidelight Protection- Landings Card -BI Date Card -BI Card -81 Date Card -BI Date PLUMBING (Permit) OK except #'s 14. Water Ht.: Vent -Access -Combustion Air 15. Water Pipe: Test & Anchors -Nail Protection 16. D.W.V.: Test-Ftings & Anchors -Nail Protection 17. Shower Pan: Test, First Floor -Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 19. Gas Pipe: Size & Anchors Date -. Card -BI Date Date Card -BI Date ' 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Meth. Protection 59. Bedroom Exiting h 60. G.F.I. & Bath Fixtures & Tub Access • 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 66. Elec. Outlets & Receptacles at Kit.'Couriter , Date ELECTRICAL Permit OK except #'s 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper Card B -i Card B -I 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. _ Fixture & Transformer Clearance -Ins. Protection Elec. Receptacles Spacing -Lights & Switches at Doors Size Boxes & No. of Conductors -Stapled Romex Installed Close ',to Edge of Studs & C.J. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 2 Appliance Circuits in Kitchen & Conductor Size Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At Range Circ. / / ga. Cu or AI -Oven Circ. / -/g a. Cu or AI, Insulated Neutral Yes -::1 - __ - Service -Riser Conductors & Ground-MainDisconnect_ - - - Equip. Clearances: Panels Motors-Mech. Equip. Clothes Closet Light -Shower Light - _ -. -- -- - -----_ - --- - Date Card-BI'Date 11-.._ -_ _ Date Card -BI - Date 69, Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor -Meth. Protection 70. Plb., Elec. &Mech. Equip. Liated for Location 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. '72. Insulation -Foam -Looked in Attic E] Yes 73. Guard Rails & Deck Construction -Post Caps 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 75. Following instld.: Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No; Planters ❑Yes EJ -No 76. Stucco; Brown -Finish 77, - A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 78, Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground 81. Ventilation throughout House 82. Glass Protection Gate I MECHANICAL (Permit) OK except #'s 83. Corrections from Previous Inspections 84. Gas ;est -Meters Tagged; Gas -Electric Card -BI Caid-131 31. 32. 33. 34. 35. A.C. Ducts. Insulation & Support _ - - _ _ Vent Fan: Exhaust above Insulation _ -_,- Condensate Drain & Overflow: Size_& Grade _ Furnace -Vent: Access -Comb. Air -Return Air Vent -115V outlet Attic Access & Platform if Furnace in Attic Date Card -BI Date _ Date Card -BI Date 85. Water & Sewer Connected -C/O to Grade -HD Approval 86. Energy Compliance Certificate -Other Certificates - - Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except #'s Com tents at Final: 36. 37. 38. 39. 40. 41 42. 43. 44. 45. 46. 47. Sills; Proper Material & Anchors Walls: Studs -Nailing, Spacing & Bracing -Plates -Sound --- Bearing Walls over Girders & Floor Nailing Draft Slop in Walls (rat proof) Fire Stops: Furred Ceilin s -Stairs -Chases -Tub Header & Beam -Size & Bearing Hangers -Post Caps -Anchors -Connectors Cing. Joist-Rfir. Ties-Purlin-Roof Brac.-Truss-Shthng.-Ring. Fireplace Ties or Type A Flue -Fireplace Throat A,Iic Access: Size -& Romex Protection -_Draft Stop -Ins. B_a_ff_les Bdrm. Windows or Exiting Doors -Sill Hgl. & Dimensions Garage Fire Protection Framing --- -' (NOTE- Anentrymust be made each time youvisit jobsile). 0 = Not OK — = Not Applicable MOBILEHOMES MISCELLANEOUS = Not Ready Date MOBILEHOME UTILITIES (Plans) OK except #'s, 1., Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK'excepi #'s, 1• Zoning Requirements—Setbacks—Easements 2. Soils; Special MH Support—Sketch 2. Footings; Size—Depth—Spacing—Connectors 3. Sewer;, L.ocat ion— Test— Fa I I -C /0—Concrete 3. Decks; Girders and/or Joists—Decking—Bracing =Stairs—Rails 4. Waiter; Location—Test—Easement Needed (Sketch) 4. Wood Awn.; Posts—Beams—Rftrs.—Conne6;=Shth'g.—Rfg.-Bracing 5. Electricity; Ldcation—Clearances—Grnd.—/ Amp'—Concrete 5. Alum. Awn.; Columns—Connections—Splice—D6cal=Enclosures 6. Gas; Location—Test—Wrap:/ /"L" ft:/ Nat. or/ /'!L"ft./ '/"LPG 7. Utility Clearance 6. Carports; Windows—Doors tits 7. Elec. Card -BI Date Card -131 Date Card -BI Date Card -131 bate Card -BI Date Date Card -Bl Date - !V!OqEHOME INSTALIATION (Plans) OK except #'s Card -131 Date Date Card -81 Date POOLS (Plans) OK except #'s mg Reqwpid'ents—Setbacki—Easements 1. Setbacks—Easements ootin4n, -,=Opacing—Marriage Line .2. Soils; Compaction—Structure Stability as; MH Test—Demand—Valve—Connector 3. Pool Structure; Steel—Connect ions—Thickness—Dead, Men— L ini ng Electricity; MH Test—Crossovers—Breakers—Clearances 4. Elec.; Receptacles and Lighting; Distances—GFI" L-0- _EiEwn; MH Teat—Fal I—F lex Connector 5. Elec.: Pool Lighting; 15 volts—GFI Water; MH Test_Regulator—Connector 6. Elec.; Enclosures;. Conduit Entries—Terminals-Listed �d Sewer Connected—C/O to Grade—Hb Approval 7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater d Electricity Tagged 8.. Elec.; Grounding; Equip. w/5'—Circulating Equip.=Pool- Lghig. Boxes—Enclosures—Panel boards—Ins. to Main in Conduit" 2!�P_rlt- Insp.—Sketch )C Cert. of Occupancy 9. Health Department Approval _w� - - 10. Plumb; Cir. Test—Water Supply Test Card B-1 ICE - Date L3—:jn97Card-BI W Date5151r. Card -131 Date Card -Bl Date Card B-91. Date ^ Card -Bl. Date Card -Bl Date Card -Bl Date r2t_ r +� MOBILEHOME INSTALLATION ACCEPTANCE •,y----= COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS — 7 COUNTY CENTER DRIVE OROVILLE, CALIFORNIA — 534-4541 x PERMIT NO. r,a Address or location of mobilehome Owner's name 4� / i Owner's address G �" .Insignia or hud number f•)r1 7 U - 7 l`— _ Manufacturer's name Serial number of V.I.N. C (Official Approving Installation) Year of manufacture -11F THE MOBILEHOME IS MOVED OR RELOCATED, THE MOBILEHOME INSTALLATION ACCEPTANCE SHALL BECOME INVALID. THIS FORM SHALL NOT BE USED WHEN THE MOBILEHOME IS INSTALLED ON A FOUNDATION SYSTEM. = 513B White - Owner, Yellow - Installer, Pink - D.P.W COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751- 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE S. - PERMIT A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this I Inspector_Date-.A. n rl• COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS , 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. �Inspector____ Date_ 07 COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville;tallfomia 95965 - Telephone 916/534-4541 APPLICATION AND PERMIT ,PEERMIITT NO. r te) Zl 5-- '� ASSESS R ICE N�1 ER �p I� ZONIN BUILDING PERMIT Ow �rsQ TEL PH E SO. FT. OCC. BUILDING V DATION OW 'S fAAILING DRESS ' ©V ` CO T R'S NAM TEO CON TOR'SAI A o- Fireplace CONST UCTIO LENDER UNKNOWN Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS l r - � Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 1 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF [I Duplex❑ Mobilehome� Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G W 10.00 ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation56 Other ❑ Describe work: _ ' /� _ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service BOOV OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full fQrcP� and effect. License No., y� Classification r ElI, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.yd 1 OR ACDNS. ACC. BLDGS. /zQsgft NEW CONSTR.MULTI-OUTLET 2.50 ea NON.RESID BRANCH I CRC ITS POWER APPARATUS e (SINGLE OUTLET CIR. I EX, OCCUp(OUTLETS OR FIXTURES zAL@3t e L0 30 FIXED EX. OCCup. OUTLETS P(RESID IAPNSREA.� 1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. byirin 15.00 9 Permit Fee $ WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): �j The permit is for $100.00 (valuation) or less. ❑` I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor ' MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating i to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agains aid County in consequence of the granting of this permit. _�_ �� Date Signature of Applicant — Owner❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee Y - — r TOTAL PERMIT -FEE $ occup. CONST.TYPe I FVJP;"fi<J PO H Issu This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTO OF PUBLIC By PWT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date �� Receipt No. WHITE-D.P.W.. YELLOW -ASSESSOR, PINK -INSPECTOR. GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT, OF'PUBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CALrFORNIA 95965 - TELEPHONE: 916/534-4541 PERMIT APPLICATION DATA SHEET OWNER Proposed Building Use At time of permit application, I was advised the following data must be submitted prior to permit processing and:/Or issuance: DATE RECEIVED APPROVED 1. All items have been submitted. . . . . . . . . . . . 2. Plot plans in duplicate./triplicate, signed by preparer of plans. . 3. Complete plans in duplicate. /triplicate, signed by preparer of plans. 14. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. . . . . . 6. CUSD "Fees Paid" Stamp on Floor Plan . . . . . . . . 7 Statement of Intent for Non -Heated and AC Buildings. Fees of $ 9. Letter of signature authoriz ise--= - �, Sanitation approval from e.pt. . Planning approval for (A) Use: (B) Parking: Certificate of Workmen's Compensation Insurance. 13. Contractor's License Information (no., name style, lassif 14. Owner -Builder Verification (Given to owner0, Mail to owner ❑•), _15. Improvements may be required. . . . . . . . . . . . 16. Mobilehome Installation Data. . . . . . . . . . 1 Pre-Inspec. request to Pre -Inspection for Required. Building Inspector (Date) Recorded copy of Agricultural Acknowledgment Statement. 119. Driveway Permit. 20. Plot plan approved -from city of 21. I 22. When ou issue the per p ess as follows: —Mail to � o�wner, —Mail to contractor. Telephone �and hold for pickup at�'office, Deliver w/inspector. Other .. I i c a n D. Copy of plans sent Health Dept., Fire Dept., Other Date The following data must be submitted 1. Index permit for above items No. - 2. o._2. Additional items required: to.Rermit issuance:,(Circle new item not checked above). Contractor, designer, owner, was advised of above required data by_phone_stail_counter Contractor, designer, owner, was advised of above required data by—phone —mal l_counter. Plans checked by Copy—DPW Date Plans approved by Sets of plans on hold in File cabinet AP folder date date Date rs: 10:00 a.m. - 3:00 p.m. ' ' v 'BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville", CA {' PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET J 1. Owner's Name: ' 1 2. Installer's Name: S 3. Is the site currently under permit? YesLeL\j No F] (If yes, furnish permit number ) OR Is the site an existing site? Yes No Z. (If yes, furnish two plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes IF4 No F] (If no, clarify 5. What is the mobilehome electrical rating? --------------- ZD -D Amps 6. What is the mobilehome site service rating? --------.---- / Amps 7. What is the mobilehome site circuit breaker rating? Amps 8. Is there any other electric load to be served by the S mobilehome site service? -------------------------------- Yes No (If yes, identify the load and size: (Load) (Amps) 9. What is the mobilehome site gas 'pipe size? ------}------ (in.) 10. .., What is the t service. -'------ Natural LPG Ej e of gas 11. What is the gas pipe length from meter or tank to the mobilehome?--------------------------------------------- * 12. What is the mobilehome gas demand? ---------------------- *(This information not required if pipe.length less than 6 ft. on .natural gas or less than 50 ft. on LPG.) (ft, ) (BTU) MOBILEHOME SUPPORT DATA If other than single wide, X Mobilehome Mfr. &RZOAS'% furnish Setup Model No. Year/177- Width ear 7 -Width (ft.) Box Length17/0 (ft.) Tagalong or Expando Size ft. x "-" ft. On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural setup sheets (if not on file with the County of Butte). FOOTINGS (check one) 1. Wood -pressure treated or foundation grade . 2. Other (specify) SUPPORTS (check one) 1. Concrete block. R-11 Other (specify):. Pier Footing Sizes. and Locations: SINGLE -WIDE MULTI -WIDE -main Beams .,! ' —,I — ! , J J �lx3e 3rxIo--x�x o Glx 0 e 2 Main Beams —_Line 1 — — — — — — — — — — -- ..�-Line Tag or Triple Line 1 Line 1 Piers: Line 1 Openings: Size -Min. ---- - ---- ik Size -Min. ------------------ „x Spacing -Max. -'------- ,- I Each Side of Openings V From Ends -Max. ------- �_ With Width Over--------- " Line 2 Piers - Size -Min ------------- On Spacing -Max.--------- '- From Ends -Max .------- �_ Q Line 3 goof Loads: Size -Min. ---------- Location (Prom Front) Line 3 Piers: (Under Bearing Wall.Only) Size -Min.------------------ k u Spacing -Max. --------------- I_ n From Ends -Max.------------- I- 1, .1. f_4 --x30 „3&`X30" ♦/���� �,x W x x Ix I, Line 4 Piers: Size -Min .------------ k u Spacing -Max.--------- ,- From Ends -Max .------- Line 5 goof mads: Size -Min. ------------ Location (From Front) Line 5 Piers:. (Under Bearing Walls Only) Size -Min------------------- ,y� n MIMMI &-DEPA -D �,• a 4 Telephone 533.2000 .North Burbank Public Utility District 1960 Erin Street OROVILLE, CALIFORNIA 95965 DISTRICT APPROVAL AND .13-87 VERIFICATION OF INSPECTION BUILDING SEWERS - This verification form must be submitted to the Butte County Department of Public Works - Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by North Burbank Public Utility District, must be submitted to Butte County. Applicant: GEORGE JACOBS Applicant Address: . 4529 Baggett-Marysville Road, Oroville 533-9166 Applicant Phone No.: Property Location (s): 4529 Baggett-Marysville Road Bagget Tract, Lots 3 & 4 A. P. No. (s): 35-21-4-02 Replacing mobiles only - no changing of house lateral to be made Fees Paid: NO FEES DUE Application for service approved:. North Burbank February 18, 1987 Public Utility District Inspection(s) made and successful test(s) observed: Location: Date: By: North Burbank Public Utility District release to close permit: Date: M .3o PSF ' ROOF L.L. RIDGE BEAM SUPPORT LOCATION & CAPACITY MANUFACTURER: FA E 110 MODEL Fkl 242 - X = LOCATION FROM FRONT OF UNIT Y = CONCENTRATED LOAD 7T-'2 —2k- oO='-0) O 18-w 2CD-2 11.1-� # O na 24 -►0 41-4- '31 ca* 53 5 52194 35CD�� 2��c �•2-a� � O \6-(D 2(o-2 X12-8. q � 5�51� 5219 � t' O 19-10 2.1-& �2- 2 P, S'4* 40 33 32� 5 2— L0 3 550e- 3853 2kx 144 W lc) -lo 21 4-0 404 sv -o 35cp4-� 9 4 ll <o22q# �r 3 # 32�5t� 1 O 3 o # 5 4139 ee °� `o e °� aPpe Go"StNat eaoh 24Y �5'• 4u. -* 4,L B 5 �o# lssoe# 3 • eme"ts p�0ved i2 0 1 Cfl229 5 21 � a� �' 113 O Ig, -G45- 399(0# 5(.51# S191# 41'b9# 1 b i2—,co 30 - 2 4- 5 08(o 0t' Co 515# �15 O 1l -2 2k --\o- - MOBILE. HOME 0 Set—up Manual I - FAR WEST HOMES INC. OPWCVW aut�w av owal o t3�a PI Pv�atian front om+ssion or d' .approve . anY .�. �eq�ui�re�entS-0 f^F�J`erauxi�rla c�se d� $onstruction and �{ t� �, �a�{, by av3itable Oahe' set of apura�e► G%'at alk illives. each pwo o� m +1u;actur g` ATC OF CALIFORNIA �a�etitti�tit bf Housing and.ComTdr.ity Development of Codes and Standards piWision +� e� INDEX s..... Page .'. Information for permit (where required) 1 Set up & Level - Close-up- .; ;. `„ 2-3 Connect Utilities'. .. 4, ,. Chassis Tie Downs 4 Tests Required 5 & Inspe.ction 6 ? ', .Completion Pier. Spacing & Capacities 7-,8-9-10 Floor Mating Methods 11 Roof Mating Methods 12 „ Utilities Details 13-14-15 Tie Down Details 16-17 , Expando Set Up Procedures 18-19 Expando Set up Details. 20 Fold Down Eave,lhstalla.tzon Detail 21 Removable Eave Installation Detailst 22 �. Bottom Board Patching Details* 23 ShipLoose - Enclosure Materials 24 ' Appendix A - Ridge Deam Support Piers l ' Location & Capacity .. . .,. . .. ., /lam- t R V 01 ark ; cif'Federal Mobile Home ; r .. requrr nests` and Safety Standard: CUwost LCfi0n' One set of; apptMad �p� � be`availat�e . at each. platy of manufaobure at all Maes. . STATE OF CAUFORNIA = ;pepe "fflt of Houslog and CA=auu* DmWpmOd Division of Codes Sued Standards 6 INFORMATION FOR 'PERMIT TO SET-UP MOBILE HOME Page 1 Mobile Home MODEL SN' Box Size of Home - Wid.th 12' ( ) - 1.4 '( ) f 20 ' (), - 24'( 28' ( ) Db1 wide w/tag ( ), Length-(; Dept. Insignia Approval Number Electrical Feeder: Size (Diam. of Wire) Gas Supply Inlet - Size - 1'.' ( ) 3/4" ( ) Water Supply Connector: Size 3/4" Type Threaded Material ( ).Galvanized Waste Connector: Size 3" Type Threaded Material A.B.S. Amp Rating Roof Load: (. ) 201b. ( 1 30 lb. C 401b,-.( )601b (.)801b ( )1001r South Middle North Other. Horizontal Live Load Blind Load) : ( ) 1'51bs.' ° ' •(•) 251bs. Standard '`'Hurricane Note: Manufacturer to fill'in above data before'piacing ' manual -in home 1. Application & Permits A. Obtain set-up permit form from local'jurisdictioti'. B. Fill out' application. C. Complete installa'tion' information' sheet.• D. Return .to office -having jurisdiction with proper fee .for compliance and approval. NOTE: Details necessary to complete forms are -provided within these instructions. APPROVED Approval of these plans does. not authorize or approve any omission or deviation from requirements of • Federal Mlobile Home Construction and Safety Standards. One eat of approved plans shell be available at each Place of manufacture at all times. S OCT 15.11991 STATE OF CALIFORNIA Department of Housing and Community Development Division of Codes and Standerdf Revised; 10/15/81 �� � Step 1 Step 2 Step 3 Step 4 Page 2. ' MOBILE,HOM,E SET-UP INSTRUCTIONS Ground Preparation A. If in park,.check with manager.'fo.r p.ark requirements... B. If not in park, or if an .approved,.concrete pad is notes',::.•. '„ provided,` clear area of-.a'1.1'vegeta.tion', and debris., C. Level' -and compact area a minimum 4f exterior dimen , s.ions- of:- coach :plus 3' - 0 Pier Selection A. Select piers with capacity as shown on -page 7-10 of.:,. instructions. B. Provide footings for piers. as indicated,.on table -on,..-,,, pages 7 thru 10.. A. Move coach or ,Utility Fi,a1f into position, -remove. ship loose items. B. Remove polyethylene protection from both halves.o.f-•�.r double wide,. , Leveling A. Using hitch jack, bring unit to desired'' height, -'18 minimum to .joi.sts & 12" minimum: to beams.,_ , B. Place two piers directly behind axle area under I - beams. C. Place two. (2) 12 ton jacks as near, as: possible to. th,e, , piers under the I -beams. D: Using a 6' level, level unit side to side between I-• beams over -the two,.pi_ers. Leave outside slightly low' on double wides . E. Using a water level, level the uni"t•from.axle area'to front -of unit using hitch jack.. P.lace.water level. directly over the I -beams on'.•"both'" sides to' level'.. F. Place two piers in the.farthest,foxward position, using-. 6' level", level from side to. -side. G. Approximately halfway between the front piers and the rear piers (closest t.o'mid point on atta"ched.drawing) place two (2) more piers and using 6' level, level unit side to side. H. Place..remainde.r of pier.s.acc,ording.to drawing on pages - 7 thru 10. I. Perimeter Blocking may be required @ doors & Windows over 4-0" wide - See .pages ; 8'• thru 10.'-'" G. If home is single wide'- Se.e' 5tp e,'9,. "' Utilities Connection-,_Page'A W . . . . . . . . - WIT 0 Page 3 Step 5 Marriage of X ,and.,U;'rHalf A. Place two (2) pieces of 5/8" fir plywood on ground so that wheels of X unit rest on plywood.; B. Spread heavy grease or sand on plywood to provide slippery surface. C. Place heavy-duty dolly wheel under hitch post. D. Move X half as close as possible in alignment with U half or utility half, with wheels,resting on plywood. Use come-alongs to draw halves together. E. Adjust level of X half to same level as U half. Place. piers at spacing indicated on Blocking Diagram leavinq outer side slightly low. F. Bolt mating clips, provided on chassis outriggers, together with 3/8" x 2 - 1/2" machine bolts'with nuts and washers, through holes built in chassis outriggers. G. Jack outer edges of both halves slightly upward until ridge beams make contact and ceiling heights of both halves are in the same'plane. Make ridge beam connec- tions as shown on page` 12. H. After all bolts are in place.and tightened, lower both units and re -level blocks. I. Place piers under coiuwnn on"ridge„beam support points as shown on Blocking Diagram. Pages 7-10. See table, Appendix A for spacing & capacity for your model. Step 6 External Close -Up A. For metal roof - i'nstall metal ridge cap using permagum adjacent to roof and at edge*of ridge cap. Attach with' No. 8 x 1” sheet metal screws @ 4" O.C.,'see.details, page Paint sides of'ridge cap and 6" adjacent roof area with Plas-T-Cote, or equivalen't.''Ridge cap for asphalt shingle, see page 12 . B. For lap siding - starting from'bottom, apply strips of lap siding in slip joints with permagum behind no screws required. C. For vertical siding - slip close -off strip into Pitts- burgh Lock joint with perma=tape behind and secure at both sides with No. 8 x 3%4"'sheet metal screws at top bottom, and belt rails. D. Place front overhang close -off strip under eave with permagum under edges and secure with No.B x'3/4" sheet metal screws @ 4" O.C., both sides. Step 7 Internal Close -Up A. Install close-up moulding along ceiling joint. B. Install wall panels.at end wall joint., C. Install door jambs. D. Install carpeting. E. Install chrome floor moulding over floor joints where floor covering is linoleum. Page 4 Step 8 Connect Utilities A. Install heat cross-over, round•insula.ted.duct,per.detail on page Secure joints with'No. 8 x 3/4".sheet metal screws at four ' (4) points around"s"lip joint 'and tape with 2" heat duct tape.. 8. Connect water cross-over (if required) using approved cross -over, -see page 15. C. Connect gas cross-over, if`required; using approved quick disconnecty Connectors;:shall,be.identified:and listed by AGA or IAPMO. Cross-over. shall be -same size as the pipes it connects, see pagel5. D. Make electrical cross-over as shown on page 14 for amperage required for coach. E. The water supply system for the mobile -home has been designed for an inlet'water,pres.sure of 8.O..psi, a -pressure reducing -'valve must be installed.,. The .water .supply connection i.s 3/4". Provide master shut-off valve at supply inlet. Most piping subject.to freezing is enclosed in insulated basement (,area between_."I" beams)., however an outside accessible outlet,equipped.with GFI is provided to plug in heat tapes. Heat tape muI�st.be listed for.us•e with mobile 'homes. F.• This gas supply system has' •been`designed..for a maximum pressure of 1,4" water column!or 1/2"psi ;and not less than 7" water column or 1/4 psi. Make connection,with connector same size as piping. Connector must be AGA or IAPMO approved. G. Make electrical.supply hook=up per drawing on page 14 for.proper 'amperage. ' H. If outside..air conditioner is used' se.e,.,page,.14 for . connections. I. Make`sewer'connection with flexible 3" connectors at' both ends of drain line 'from coacth topark sewer inlet. Step 9 Chassis Tie Downs A. Install chassis tie downs at locatJions•as'shown on page16. These must meet the capac,i;ty +as shown on drawing 'on page l-6. Tie downs spaced ' as shown..for 15 PSF are considered mimimum required. ,x These ti.e downs provide a 1.5 safety factor:: `..' . B. , _ Vertical ties not required .for multiwide units. Page 5 Step 10 Tests Required A. Water and drainage - if water'at'normal: operating pressure is not available, the.,mobile home water piping system shall be tested by a 100 pounds per square inch air pressure test,.for a,.period of not less than 15 minutes without,leakng. Th.edrainage piping system shall be tested'-by..letting at least three (3) gallons of.water into -each fixture and receptor with not visible evidence of leaks.• If water is available at normal operating pressure; it'shall be connected to the mobile home for a period of 15 minutes with no visible evidence of leaks. B. Gas Piping- the mobile home gas piping system shall be tested before it is connected,to the gas supply. The mobile home, gas piping'system shall be subjected to a pressure test with all appliance burner and pilot valves closed..The gas piping system shall be pressurized a sufficient period of time before testing to assure that the . temperature of .. the - air, in- the piping and out- side air temperature.are equalized. The source of pressure shall be isolated before the pressure tests are made. The test shall consist of air pressure of,a least six (6) inches of mercury or three -(3) P.SI held for a period of not less than 10 minutes without showing any drop in pressure . ' , Pressure ,toy -be 'measur,e.d "with a mercury manometer or slope gage'.-: Calculated,'so, as to read in increments of not greater than -one-tenth pound or an equivalent device. _After satisfactory completion of test 14' inches water column and check appliance connections for leakage with soapy water or bubble solution. Gas•appliance" vents shall be' visually inspected to-insure,.that,-they -have not been dis- lodged in transit and are securely connected to appliances. C. Electrical - the electrical wiring and feeder assembly of the mobile home shall be tested before energizing. "All Electrical fixtures and equipment shall be connected and all branch circuit switches or circuit breakers shall be in the "on" position. The electric -al wiring and feeder assembly. The test shall be performed by checking between each supply conductor•,including the neutral conductor, and the mobile home',ground,c.onductor (green). •There shall be not evidence of any:connection between the circuit conductors, including'its neutral conductor, and the grounding conductor. .•Upon satisfactory completion of the test, the. mobile ,home may .be connected to -the lot or site service equipment., Page 5A Step 1,-)A Drainage " of plater Li ,,es If the home.is going to be vacant and without heat.in areas --subject -to'- freezing, temperatures,", Either ',of the following two methods•should11be-followed to prevent freezing of the water, lines inithe'homes A. If water lines inside the 'basement ar.e, sloped for drainage (contact -!manufacturer for information), disconnect,:thelprovided exposed drain caps under the'home,=open"all water fixtures -inside home-and•allow the water•in the' lines t'o 'drain,•'oute Re -install drain caps. B. If water lin,,s-inside.,the•basement are:ndt sloped ­for drainage, ' disconnect,t the exposed drain caps under the home, disconnect the lines from. all fixtures inside,,the home`,and -blow. out all remaining -water in 'the lines :using . an air pressure•not-exceeding~80 P.S.I. NOTE: Some components of the drain system maybe shipped loose with your home to protect them*,from•in—transit damage. All necessary ABS pipe and fitti.ngs'are provided to bring the entire drain system to one distribution point: These. . . fittings. and pipe should be installed by qualified personnel. using cement suitable for. ABS pipe. NOM.All.exposed'P-Traps-located below the bottom board at time of- set--up,..shall be -insulated to •prevent freezing. AAProvol Qt tlt�ua P 0�R.orti� ac ap�c (tame Construcu n and Salet1 o &Vtatwn IMM i iNlto�@ft�� it bo aYadat:.c at eacd piece of Standards.4f, sit 41 manutactute at all ttcao�, , ;OCT 1 i 1985 stato of palitern►q Department of Mei m a4 Community Dtve wl ent pnnuon of Codes Nd Uande.ds • page Step 11 Re -Leveling A. After a period of thirty ( 30 ) days, it is racommandad' that the coach be re-laveled following the same pro-. cedures as previously outlined. Step 12 Inspection A. Twenty-four (24) hours prior*to expected - ,tima of inspection, notify the enforcement agency of the time installation is to be. capplate.d and raquest an,inspaction. Step 13 A. Repair bottom board where necessary, see attachid• instructions. Page 23. Step 14 Skirting A. When a home is skirted an inspection panel not less than 18" in any dimension., and. not lose than four (4) square feet in area shall be located.so that utilities under the coach may be inspactad,'­11t shall not be fastened by any connecting means requiring the use of a special tool to remove the,panal...", B. Provide ventilation grille equal to two (.2)'squara feet for each 251 of perimeter. Step 15 Touch up painting of steel frame.' A. Should any part of the steel frame,become exposed, the areas shall be repainted with a zinc chromate paint or asphaltic'bes paint or a paint.certified by the paint manufacturer to have equal.corrossion protection. revised 8-9-78 FIELD"INSTALLED WALL`''FINISHINGS In the advent interior wall finishes are to'be field installed by the Dealer or.the Consumer rather than Factory installed, or new 'finishing"mat eri.al"applied over existing factory "install ed'wali1',firii6hes; 'all materials' listed for use - below shall'meeV`the'required .200 flame spread rating of Sec. 280."263"", and" Inter pretative, Bulletin C. - 1 - .7.6 of 'the Federal Mobile Home Construction•and Safety;Standai-ds-: A. 5/1611*or thicker gypsum wall board B. 3/16" or'thicker Lauan or plywood paneling C. Unfinished demension.lumber ( 1" nominal or - thicker ••boards) D. Mineral. base. Acoustic Tile .. The above materials.( A - C ) may'be,finished with natural gum varnish,•.latex.-or alkyd -paint, or 'wall paper. .; . 4,. . CAUTION: Wall and ceiling finishes �of furnace and water heater compartments .shall -meet a.,... flame spread rating not exceeding 25. .,.. Wall ceiling, and• -cabinet-° finishes within . 6" ' of each side of;`the range top 'shall meet a flame spread' rating not exceeding!�50. 1AUG.:10 W3 ,%� w..ww~ 0 I I 1 1 I I 1 1 � I I I I I I I 1 i 1 ..•i _= I .. 1 /rte/ 0_7! I• I .j It7 Q I' a I TTS Oe.+. .Q.oae l 1-W------1•--1--�--6i--ro F- ±77—T----tc�r7i GPICIPLISt I I I i I I 1 .1 Norte E.' /� � � � � � 1 j 1 j I .1. I I I 1• �/y I �j 1 C7 I •„O 1 O 1 1 D- 1 Cl O GInsawaram Inc." MSX. SVOGIN4 O O•C. WINPOW 4% poor- ' use�z OF PL.o+V O►r1+1►Iq Foo SINGLE WILES RIM jCIiT 1 It PLACe FIB{C. AT Icp" e+r OP15K PAC44 e d olt Mona IN wlorw. 1 Plfa ePUC,N6 90+466 60 Mftd 6=0'04• MiD.&T^A! Ilo'�Atll. /fY4.6"m I P• R.00e Ba*m Cows+ asvoar L"4TQF.* { a66ATea Lora* ►oa K"" pA000_ sae M,p%.W OW AT►ACH" POOH w TMIS MA41YA1.. SEE APPENDIX A !. P:AGe A P1eA AT iA• iIW o/ A M►�pow Oil cook Oo74,0 odSa-o-tT. MOB. 4• MINIMUM 0IST-0-AO6 FROM G"Wwp ro r_I•IO.SSI5 : Pl6►M • IZ� '' ANO 10• MIN �CoVNo T•2 p1..Goe= JO�sT 69NP LING WALL ONLY - Plea i Pa•o Sca iou.s coa3Q- L1. - SuJb►i W��7er ` Mu.TI•i1/IDt• •.- _. ., .r-....,..� ... � , • R+oAi RI or.. i 6Ei1w 8e�"� ' ' �� FooTwo'- pI1:R %ot�uo Pira LOC/ftT10N � C+w�c.ITY. L Foonwo C. Pw IT1/ S4-w•. C"An,c1rr Sq 11.4 PSFi eil ��n.�w• QGQ,o (.es • /000 23iY _39.0__ - 1773 •• -�i�wZ 2sls•_ _Cw..�•s _ ' / f90 —� 8L __• --Z/6 • - - ,a1'os__ t9o_. .. s_sss J68 100 o— ?2.7 _1773— 170 _ (99U PswM.Tew • /coo_ _/9( /t!L - —/9.3 . +KGwrw.�.A /coo.• 3f07 _327_— _•2SSS 24S /Soo Gw.•64s —, _,•• 2000. SE �_ 236¢ _ /70 1773 _ /26 P+da1.,eTw zoo* o�x _ /990 •_- -Iola _ i+12 i07 * COOT>X4wK 2000 _...�t?aI� —A 31w7 ty_s_ ,tssS — /e9•• 2000 Crloss,c &Soo - 236)' _ / 6 /773_ _ /OZ • - PecwcTsra-•--_. ..---.. .2600_ _ _0 _ i/t7 Cw.ea"a�e-_-- - M 2500 _ _ 31/07 %!4 25SS. .�: RiOo.• Besw 2600 .. _..... ,%� w..ww~ 0 cl 1 0i, 13 13 _3 0 Li 13 00 1 0 0 0 0 0 Ft 4- V#k.Q0Gw soppaqr. 3" Nwa e. F 1 0 1 1 a I PrMimaTua. pwma MAX. limpuc-Imr4 0W. W wlp�pcw OO,Ckw- w, It QIM JO01-T PL -ACG P191M AT %I Go ow .4%,O'OlL M w IN WIDTH PIER bp^clhlG, &44" 6'-0"04, A&JO OTAkqr 0,0* MAX.FIROM 6"00 P. RID"SAcolwbw&$-Oar O-iaLCATocs r ,-zao *"OW" *'j A'yr^C'"50 PI%M lN MANU&A.-. ZUZ ApmFN OIX A% PLACE A MAI% As f"CM cwh W'# -POW OA 000sk OPP4'a, oYVR4' Orr. WC119. f AND Igs, "M-, GSZ04wQ. TO FLDOrt T. S. uNoma ewzA-,l%irIG w^4.L- ohiLy. P_ Arm LOC.^IroN' BEAM Plea FboTwa 75" 170 try.OOtrup Loac Fc--,-&" C+pw jTy PmL,iT=Q 1000Apj�,E 1907 PIIA 4G51 ]20_ 32r5..., -Zss fts) Q,. OV S4.z 7 WOO 40 1773 A* 000: PZA;P4C7CJX 366 #2115 7-4553 Q.0c.% t5ca� v zS00 470 2500 11500 1500 t Z.31 4' 17-7b 170 2G4,Z 'L — 444 901 180 15.00 46515 497' 313 1500, 75" 170 ZODO 177 ! jza PmL,iT=Q 1000Apj�,E 1907 PIIA 4G51 ]20_ 32r5..., -Zss 171 ZOOO S4.z WOO 188 PZA;P4C7CJX v zS00 2500 75" 170 177 ! jza 1907 • 4 4G51 ]20_ 32r5..., -Zss 171 102 S4.z 465A 188 4 I 4. I• : 1 I ❑ 1 ❑ O i ❑ 1❑ ❑ i O I ❑ 0i ❑ IQ- -�--®--T--$-- --C --T-- 1-- -- F' -T-- --w-Ell S eroar See c..Aaalc I i 1 I 1 vI a 4tc ` I I 1 I I I I 1 I 1 I I I I 1 • I 1 I I I 1 I I I I b I pI ,.0 1 O' I' I3.' I D 1 O 1 D OI MAX. SPA,C.NG Old O.C. � WIMOOW OR DOOR' vrom Y2 OF Pl, FoR 6tN6Lc WIO�S OPeMiw4` • -11-IE2 AT .0{ .I 96 pbSQ - 01.a NINGO 4 =0" (M ►WOGS , IN WIPTM 1, Ptiit OoACING 111N4161 64 I -WK, W-0*04• wd0 %TAAT IWM&A.Plalom 6110% �. Rio" BIww1 CO►uma &owoRT LocAT•ONG . f 466AXaO i.00 & roA 6Ac.. W4066 AAI %o-pytd OW ATTA4HAQ PAM t11 TWIS MIY.II A,6. SEG APRej IOIX A ' S. PLA44 A Pew N SA.. 4os ow A Ml..poW oa 000a oPsio orsliL'•o'orr. W•oe. 4. MINIMUM DI%T%mCE- Im"m 6."W40 -TO G4AS'SIS I T'.6LM 7Z• OND 10* MIN GROUND To FLOOC JOIST. _ * 5. U1dOGFR lbmpI RINCs V%,A, L, ONLY .Ploy + Pr -o Scw60v�0: Foa g_ Psi LL St1.w►t W101 i Mut'i-WIOA RIDGe. _ OGa 8'o.c. Rbq'o 6 o.c 6 o.c.Rocl'o. 6'0.a PIER LOCATION BEAM BvM Pten FOOTIVO Meq Foov,wo CovACITr. . Foor...w C.O.PACITV Spa 'Am: G.vAcIfy Sp IAds (PSF) ens �an•Iu�) Recn'o Lei R.to'o. C.MAAGK • 1000 23(.4 j 40 1.17 3 Z55 Pcnws.a.a 1000 µ7S4 I.e5 35..(.- _513-- +� Cwrtaaa+w+t 1000 81 39 ) III (.l04 079 R.4xwa Baw+ .... _. - • -' 1000 _ ^ Crwcr..0 1500 Z13(.4• Z27 177', 170 P4:a,M.cTwa 1500 47 6 w 45(. 1354.(.. 54 Z . W GwTc4a�..x ._—... _..---- IFjOO -- ---- — --'- g11.1i9 761 .... (.10+ 56(. I c". Bdi ft4 1000 t C«A1i.L -2000 E E 29(.4 170 1773 1 S PmtNirtmw • ZooO DIK - 4754• 2. 9WZ , 5-36L 257 -- ._......__. .. A Ce t■a. +.1s 2DOO ..A%pE at 59 56(. 410+ 4139 L2.044. f3c.4. Z000 CMAI.SIS —. 2000 _ _ — 2Dir4 10f. 0.773• IOZ Ptair+erra 4754 274 'SCL Z06 7l CaAlsAwx -- — —_ —._— _2-300 - 12500— .. - - — 019q— . —.- 4&9 —•--- 41046 -- 952 Q.Oor Bw��_ 2700 � --.. . PA6e D i O i y .C] . 1. O I O � •� I ll� p 0 0 O tO O ; Q O; O. O 1 14,p, Qcmw Ow. Suppoar Zee vlaa.. •� I I I 1 I I I I• I � I I , I �.� Naha t. , I I � I I I � 1 I I I . I I I I I�� • I pe 1 I ' Ila--�--1--�---�---�--�--�•--'--�--1——�—�-_k'..q b vaclMarrc Iww O I p 1 O 1' O 1 p pl ; MAX. 4Vp,CaMCi S•�'OC .. •.• ...., , WOMMW do "OIL rbOti JOIST H►K. orsNMll Klw� Jril�� b�1 NdVI PERQr6m4 LUL TO GLR. %)= . �MiTlQ AlMREQ Co b' -O' O.C. PICK. PLAGlME�J'T �JMIE41 OR1.1�J ll►IL �wwii 1 �R '+T sort o� • I- oR Mo6.� oc,Lua% a MlRI�OT ON . WlPTM 1. Pwt %-^Clpq &4%6L So LY►tl. OI O'os„ M+o'arn►/tT 1�0' . °Ivow srws t• Rio" boom C"w6w a.•rar• jar470'm + aosalo 6"00 pai !. RAW A RAW A/ a^. Nae M I► Mposew OR Doan Owv'l �MrA4—�R 1rpf. 4. 60141418AYM 011T%"Cl PaFAfty IiKOWJpip CY►f'Sl.� •,_ 1aO< ISO lwD W IA1N rw"#mD To 14.a e= J04bTs i 'dw . . I -. . -..-.. - PMrlt ► A.o SWi'OVLX Roti loo PiW Lt. • ' Swam h/wa�' j Mu►�i•1JIoi ,._ ._ .. i PIa;4 10�.►TIOP1 CrwAGI> RK1G0aha Bre O.C. 'O Prw O O.C. �ovrluo ' O{• O. P1amoon.p � �(. Foo+lyo Y. Isr) .a• F l Ci~'vw. 6a•ws. CM'64fry , S• am. .w lob - ' Ileo. Pin�.ro•�a -__ __ 1177• sal al — -- Cwrlaaurus 1000 ' ---- 5970 860 +t,77 64'S 1000 X0212 /470_ rw►K�� IWO .1711 170 _ f�firnwe�all� -• . « S1f.♦ t's7 _ ,— _ IDoo __ 6970 S7� - ++77- 430 �raw.� 980 _=659 ° 735 Is co g- G . _ PI.a1Mrt�la _-APP9 NAIA:_. s�«_ 1110 _ /771_ 1 ItsCsul>,a4.lac , %Do* .._ - --• ', 597D ,C 322 X02/2 735- - poop -- .•- --- C..oss�s 1171 t IOL P4�a.+.na aaloa -. , - - ! l� IK . Wao �. 970 3�_� 4♦77 2S8 asoa '— Sg 7b 9 - .L -t't1_ Roost M^ToNcp METHODS. . iw�e"L'�"r i�iii•• iiia ?`} . h.__ . MA.aa►n,ae C.t-110 MNATHOO. F 4" (MtIJ. WOOD SGCtEWS . P1`G'C HOLES MV SZ . ft!. Dn 1t_t_EO . S C-rLF-W S MANN lbv- Pt.NIGCO IAB NR.GESS�.TLY. �Ir��S OEZ►.�L. VA" RaE v..xv-b OF-TVAi'c. MTcYHODS SNOW► Otl "C'H15 Sca�1i- t : , 'f t' ;To tus+ Titoss Roo MUT►+oo. OGM-T VV/ WALK�R,S ei-O oc. . , , .•• ,� ,t Bo�.Y-fox MsT►,wo. . M ETWO V 1 �� StJEET ME AL screew-� Q 4"O.C. YyyAI3oLTS wf WA51�-E.t� & 8l o"O•C. Gi fl �WJcGOM SE4L MET&L- HOOF 30ya. GAL . MIDGE CAr. n i1- 1 5114C,Ls WAL.LL- F-O� j �OUf!>LE 6UPPOOT W&,LL ' 20 4 30 PAF 12 OOF 40 4 8o 95 F QOC)F 1 METAL. ZOOF - EXP05SO VSEAM METAL tr-OOF CAr INSTALLATION 1L1'woop eGGESS l l I 30stw METtaL QOOF GAP I2 0 P>DL"�S VJJWASWE-C 1" QEt�MtaGUM ErY9) if00F SNENTWING ? G''s�,YwD C=-TV-IF'G. TY P. BULL L..EIjCy" OF (P4 v • os CO V EIZ- w�C.vol_ SC 204 3o t'st= tZopF 3uppt ju 404 80 -,P --,r lzOOF CONcEQLEp eFI&M - METAL OK 6VAINGLED GOOF CONCEALeD OUN4 - hAE-T4,L GOOF G&.P METW00 5 V,5 ",K 3La-, sc;.t=w5 c.OMPo-fLlt�iGE C4P-*F-1ELr> Int'5T�t.-LEC:) I-0" 0.C- STW-,,C,-E P12 P_DOF NAILS Ga 12OL. I�001= Sl-lE1�TUlf14 OHc Slee P-�czL:ED �cONPO-5t1iuC,t_ES� •� .5 �o�4N IcPI j ,�oF pLY LAP BELT@ 4�ttX,G 2031CP pSF SOF 5upv T✓4o 180 PSF VLOOF CONCEALED lEAM -METAL Oil tWN4LED 12OOF CONCEALED 5EAM - SU 1W4qLF- 4'DOF CAP At -TC -V -►-ATE tt-aoF MATING; METHOoS X001= JOINT SEAL(Wa METHODS U� Side Floor M4+'� X- SKAe 3" Dro:,n I%r.e S"pport l-- Collar- (To be installed A55 P.pe Str-o�pr�. durlr� sQ�-vp) NOTE: Apprv1! Flex -C•or%r%QC+c - sho,%% be, nN-5jmi%ed of e4, end of dreom 1^e �roM CoO6\ to park sewer inlet, DRAiNT UNF- CaossovER U- Side. Floor Mat') X -side C -aim I i L,.,..W....,�......1^i - Gas lyes �o�ned by C oci k Ptex GA , ' 15 YVATFa LINE Ozo.;,up RR i AJOTE5 Min. „�c,,,�, Is reed 4rcnm -Fn pork servp<Q, .pprv'Cl wa-ker. . c,os%Cwe r cor%nec4c�.••s rpq'd . CroS-,ovCr� sE.411 he tl,e; sone -,izc or b -.-der ck tl•e p•pc� in +tie rno6�lel.on�e a,A- -k1-,¢ 4/,d with mn h rro✓ided by M�r- NCil Fto be Gr r_ gtlntr Gts couch in/et Crc•:-.�,-e�- s1 -,n11 be i+\e SC.ry a !"ze_ us 4e p,pes w\ 4�\e chlel.on.e a� +ke. Cros5ou•c.r. CO-?7ec�fOns .rade wi1,1/1 1774f'/s sarpp/ic,Y ,6y /1� , •r ' MELD CorqN"S Wn•}er,Gas E SE 'er- 9 J - C30x NOT ' '` Cor;�eG�►ors shall, be " "+pmwSQIltebol� Gonr\ec�'Cr or ed / re MW) &1N. SERVICE CU E W AL v-,ipf 'r HW (AMPS) CONDUIT SIZE WIRE' SIZE, ICONDUIT SIZE NiRE SIZE .z00 2,"• 0d0 2 Z50M� 9.150Z.��__— - .- 400 ._ 00 5100'. 50 3: U-S;Ide Floor MCAVI x -516e Ou+r;�er Floor 61st -ter J - C3ox J - (3oc Me+r;1 Flex- C'o.Kiv'i' C ROSSOVEl2 N IE Camdv%k used A•o Ice c,r� app'-v'c\ tkkpe. Usa solderless w%re conr\eciors All 15 L ZO Arr\p' cressover-s s1\oJ1 be color- coded. -Car.ier•ed wl+k solderless type c4,r.eL+o�-S Utis.tonr\ect �cc- A�G . Flax Cor\dui} N, U►v'unde m oe u� toad,,' Access pw z t)t mvs4-be, Provided ,r. Pckf\e1 L0X ww". 6e u%; --d (A�sconrQci .r 50he} sl5k+ dsfi. QLAs,dc Of war -6. ! (j_�3�„� Cup t.,/,) -es ire ,Lunction box I f FteA Cor\A'j ''u1fh sc'o t-ch70cks or eguo/ qc cu WIRE 0 HW) AL Wil -<E (THW) SIZE AMP. CGtXj1T SIZE W10 SIZE C'ONcur SI -L>: WIRE SIZE 3 30 I if l0� 8 3 s_ 40 8 4„ 8 4 50 1„ 6 l •• 6 .CIRCUIT CU WIRE(T-HW) AL wiRE THW (AMPS C.oNarr s►zE WIIZE SIZE CGNW1T jIZE vVIRE SIZE. I 15 lI) 1 q, i '' 12 20 Z �� I Z 1 .� 2 10 s0 r„ !„ 6 5:10 pA>ykL 100 CUB a.,r %- t=1EL0 Co,,,N's : CIc c: j &-pp'll A/C . d ve rLL J 6 a a LL i o /CY vi C e 0 I SUPPORT AND ANCHO'AING SYSTEMS INSTALLATION INSTRUCTION Design Criteria. 4. The main frame structureshall be used as the points for connection of the . diagonpl ties (See Figure 23A). 5. Typical frame and ground connectors are illustrated in the Figures 23A and 23B.' 6. The tie down strapping used in con- junction. with above connectors shall be the equivalent of Type 1, Finished B, grade steel strapping, 11/4 inches wide Strap and 0.035 inches thick, conforming with Buckle Federal Specifications QQ-S-781-H. 7. Other approved connectors may be used providing they meet the strength requirements outlined on page 38. 8. Grounding anchors are to be an ap- proved type and installed in accordance with the manufacturers installation in- structions supplied with the anchors. 8' of Strap' 400 to'500 angle. 1 I See Coil Derail Frame of € 1 -Beam {i it Pull B' of Strap Thread' As Shown. Straps. Mi.ist Re Adjacent to Outrigger;. ,I 'S Coil Detail his Section of Coil foes Around I•Beam FIGURE 23A. To I -Beam See Coil Detail —� r— INSTALLATION INSTRUCTION Frame Head 40o t�� 500 / angle --.( i I 1. Ties shall be as evenly spaced as 1,—�a�,�, �f _,j,�r,- -• practical along the length of the home `��`"` `� with not. more than 8 feet open end Diagonal Ground ;''vertical Ground spacing at each end or /2 spacing shown Anchor Anchor in table "A" - whichever is less. ' 2. The djagonnl tjes (frame ties) required To I -Beam can be determined by reference to Table A in Figure 23D.. The spacing requirements are based on your geograph- ical area, Zone 1 .or Zone 2, indicated on your Data Plate. Coil Detail 3. Multi -wide homes require only the, diagonal ties. These shall be placl;d along the main frame and below the outer sidewall. . au _ di= ai -, .,; i: -fir_-,• • j Frame Head Pp°IESSIp i69. MIS if fig `CIVIL if or cau�°� I Q Q o J o �� 30 I Q Q o J J .I Z 1 Z I1�1 o ri f� ri LJ LJ LJ LJ n ri 1 LJ IJ a LJ J a SOUl J J .I Z Z o J a SOUl �1 Qo0 v ■ ` � / is • . 1 T t 3 #8x1%s ici�a"Nwcr�32'o.c.Sc�wzw@2"O.c- ww .,Row J .EA 64 w12-IOd 3 r, Oar. O OIC Awm. So�FiT #8x2' ' Sca .:W leo C nsP ` TU os @ IVoG. DErAIL . -f NO' Scow { F A. Fold. down eave B. Install #8x2" screws @ 32" O.C. C. Install optional' .019 Alum...Soffit • STRAP(9 9'$'o.G. SUE OMAU. eF-LOW Rooms PLY Oar) Taoss R-ywo. SP►,ICM / i/,� i • • �. . CMUNG MIA %. 1 `� � �I • ' i ` •�itb .rye .. -.. Topt 1x4 1 coo Ca i h' o�c. aGQ'c@ 5TH Ix4@24"QG. SOFFIT MW'L. R.Ywo. SPLXZ 2z COAX I Ile"WIGS x ze Car►L.v. . MGYN . I(o" MN.yc. STRAP 48~0. G. - w16- 8d TwSs 1 %CF I v*m (Opr) fx2'S44sw poll i >< C6IWIJ i MAT'L. Ixb ' 1-16d an Tsc I x 4 e 24 o.c. w/2x4 faA. srggp $oFFlr No. 10 x 2'/z" W000 Sc"w (Flet.0 WSTA"GO) 30PSr- REMOVAgL.E "EAVE QETAIL.. No Sc^La REMOVABLE EAV INSTALLATION . A. Temporarily support eaves'„in .place �.. B. Attache 22aa x 1� x 26” Galy. metal strap @ 48" O.C. W/ 8 - 8d nails.each end. + C. Install # lOx2�"- wood +screw's' @ 32 O.C. D. Shingle eave as require & IOno__ 1% .R I__...re PLVW G ED GE NAILING PLY WD 'SPLICE EA -TRUSS 3-10 d Q EA.2Y.4e r -x -r. PLI'W,D, REd D. a- to 4. Tlip. Ira d 16 2x4 . , I . V -*-T. 5%v %%UA TRUSSES 0- Iz" O.C. WIOX3�'SCREW- I er G.C. D5L."aK4.TOP FL. 2v.4"5 e 1c; O.C.. 2r.4:5 G:'O. C - .FiF-L,D INSTALLEDEA\jF- DETAIL 4,0 80 ?'SF 1XI;ISI CA om CczosS JL J - BOTTOM BOARD PATCHING INSTRUCTIONS The suitable method o'f sealing openings in bottom board is to use.2" wide -pressure sensitive vinyl tape or duct tape'. Small tears -in the undersiding should be.patched by running 2 inch tape the full length of the tear. For larger tears run.tape perpendicular to tears, 4 to 6 inches apart, then run tape full lendth of the tear, making sure the opening is completely sealed. For openings provided for projections of pipe, conduits, etc: an 'X' cut should be -made in the BOTTOM BOARD. The. corners should be folded along the projection and secured,to the projection with the tape making sure to form a complete seal. The following tapes are acceptable and should be locally available at building supply outlets. The manufacturer can be contacted for availability in various localities. MANUFACTURER Tuck Industries, New Rochelle, N.Y. Tuck #207 Darzes Container.Co., Inc•.,"Sacramento, CA.- NOPI 2" Vinyl Ideal Tape Co., Lowell, MA. Grade 370 Shuford Mills, Inc., Hickory, NC. OF -709 Shuford Mills, Inc., Hickory, NC. VF -710 Nashua Corp., Nashua, NH. #362. Kendall Co., Wellesley Hills, MA. Polyken #82.7 Adhesive Tape Corp., Brooklyn, N.Y. #480 -NOTE- FOR BEST ADHESION, SURFACE MUST BE DRY & FREE OF DUST OR DIRT. „r Ship Loose Close-Up Items 1. Lag Bolts for* Ridge Beam Mating 2. Tie Rods for -Floor Mating 3. Roof .Cap - Metal. or Composition 4. Interior Moulding 5. Siding Close-Up with channel for Lap Siding. 6. Canopy Seam Closure. APPENDIX A Ridge Beam Support Piers & Location of Capacity. 41 1 PERWT NO. 6874-79MHI existing si tP PERMIT EXPIRES uZ13Z80 OWNER GEORGE JACOBS CONTR. Lincoln Village MH I LOCATION (A.P. 35-214-2 ) 4529 Baggett Rd, Oroville u a Temp. Power Pole Called PG&E Temp!VElec. Serv.— alled PG&E ; Temp. Gas Serv. Called PG&E ,JOB FINALED (Date) (Signatur Brown Finish Interior Latl Doon.. rr Closer MOBILEHOI 'Water - OBILEHOI Water Piping DATE I MECHANICAL Heating Cooling Ducts Ventilation Final S ----------•-- --- Elec- Service L 7 9 Sewer (L Y ? ATION--------------Support Drainage REMARKS OR CORRECTIONS Gird. Fault Pro Service Temp. Pole Underground Permanent Final Elec. Pedestal Gas Piping Elec. Continuity Gas Piping (NOTE: An entry must be made on this form each time you visit the job site.) 2 COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS ` BUILDING INSPECTION RECORD 'BUILDING BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out. Slab Roof Sheathing Water Piping Piers • Roofing _ Sewer Garage Fdn. Vents Fixtures Footings Stemwa I I Garage Vents Insulation Water Htr. Heaters Slab ort Footings Prov. for psically • eCar Conformance of ex. structure Appliances Gas Pi in &Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls I Throat Rough Reinf. Steel I Final Fixtures Brown Finish Interior Latl Doon.. rr Closer MOBILEHOI 'Water - OBILEHOI Water Piping DATE I MECHANICAL Heating Cooling Ducts Ventilation Final S ----------•-- --- Elec- Service L 7 9 Sewer (L Y ? ATION--------------Support Drainage REMARKS OR CORRECTIONS Gird. Fault Pro Service Temp. Pole Underground Permanent Final Elec. Pedestal Gas Piping Elec. Continuity Gas Piping (NOTE: An entry must be made on this form each time you visit the job site.) 2 9. Electrical A. Is service large enough to provide adequate amperage -to mobilehome (must equal rating of mobilehome with a minimum of 190.amp) and other facilities.on lot,•i.e., water pumps, garage, cabana, etc.?' Yes No B. Is there proper clearances around panels? Yes" No_ C. Is power supply cord or feeder assembly properly fused? Yes' No D. Is continuity test satisfactory as.per the following procedure? Yes ✓�O 1. De -energize electrical wiring system of the mobilehome at the pedestal. 2. Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. 3. 'Switch all breakers and switches in the mobilehome to the "on" position. - 4. Connect one lead of a test instrument to the mobilehome grounding conductor and apply the other lead to each mobilehome supply conductor, including neutral. 5. kAll non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. 6. Upon completion of the above.pr.ocedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the -� mobilehome. Upon satisfactory completion of the electrical tests, the lot or site service equipment may be approved for energizing. _ • - 10. Is job card signed by Health Department for water and sanitation? 11. If everything okay, sign off -card and tag services. MOBILEHOME DATA Manufacturer and/or Namestyle Length 73 77• PF Width �Ly. /7l � Vehicle Serial No. �. State Identification No. P7 / 7 Additional Information or Comments: MOBILEHOME .] 1. Is the mobilehome located with�equired separa conform to plot plan? Yes ✓No 2. Does the mobilehome have required,clearances a 3. Are footings and supports properly sized, spac possible variation -at spring shackles.) (Secy. 4. Is the mobilehome level? (Sec. 5088) Yes ✓ No CHECK LIST Dn from lot lines and buildings and generally ve..ground?.(Sec.5085) Yest No and braced as per approved plans?. (Note. 32 & 5083) Yes�No 5. If mord than a single unit, are crossover connections properly installed? (Sec. 5088) Yes_✓ No_ ,.. 6. Water i A. Is flexible connector of adequate size and properly installed (1/2" ID min.)? ..(Sec. 5566) Yes_✓ No � - B. Test - Does water piping withstand working ressure or 50 lbs. air test? Yesy No Backflow - If coach is not State .of California approved, does station have backflow device and pressure -relief valve? Yes_ No 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at each end? Yeses No B. Does it have minimum k" per foot slope and is it properly supported? Yes cih% C. Are any leaks detected in drainage system after running 3 -gallons of water through each fixture including washing machine standpipe?, Yes No_� If coach is not State of California approved,,does station have required trap and vent? �. Yes No 8. Gas Piping and Gas Vents A. Connector - Is mobilehome connected to the gtas supply with an approved 3/4" minimum mobilehome connector riot more than 6 ft. long? Note:. All piping is to be at least as' large as the mobil ome gas line inlet without*reductions-other than the mobilehome connector. Yes_ No_ B. Test OK as per following procedure? Yes lIo_ 1. Open all appliance connector valves. P 2. Shut off appliance burner and pilot valves. 3. Air test with manometer to 10"-14" water column, or test with slope gauge (minimum 6oz.-maximum 8 oz.) calibrated in tenth pound increments. Test for 10 min, without drop. 4. Connect gas meter to mobilehome with con ector, turn on gas, test connections with soapy water. C. Are all appliance vents properly installed? Yes No COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of the California Administrative Code, Title 25, Chapter. 5, under permit number / k7 V l `% for the following location: 41 5 Z Owner �'�o1�-rsn� dtG�ss i Owner's Address Mobilehome Mfg. Model 7 7 -71-/- Year l Insignia No. 17 6,Y1 1-/c;_ Serial No. % / %fid % It is hereby certified for occupancy at the above described location and may be occupied. Director of Public Works Date J L ��- By THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED White - Owner, Yellow - Installer, Pink - D.P.W. COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 695 Oleander Avenue, Chico — Phone 343-4211, Ext. 70, 7 County Center Drivq, Oroville — Phone 534=4541 Skyway and Elliott Road, Paradise — Phone 877-3435 CORRECTION NOTICE BUIi6DING OR PROPERTY ADDRESS A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. Inspector Date COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 Tel epho 4:.534-4541 r .. r APPLICATION AND PERMIT autho ize re esentatives of the County of Butte to enter upon the abov -menti ed prop rty fo inspection purposes. ie Date Si azure ofPermitee or Agent fP Receipt No. ✓ 47 S"Z-- White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of e utte County Code and/or resolutions to do work indicated XE OR OF PUBLIC WORKS � Date 74 ' 7f Building permit expires Date _ 12--41-,90 BUILDING Owner it���"� SQ. FT. OCC. BUILDING VALUATION Mailing Address Afzxt h awr I Telephone No. Contractor ���� � a wu m L' Mailing Address �I��L�. LZ�Vp. Fireplace Total Valuation O�yt`l�: T+ �{r��N'�14 Permit Fee Building Address � �j29 6Ae, E T -F r—b . Plan Checking Fee&/or Penalty Permit Fee PLUMBING No. @ FEE PERMIT FILING FEE $3.00 .Oa Each TraD 1.50 Repair drainage or vent piping 1.50 5, Z� A. P. No. Z Zoning & Planning Water piping 1.50 Each gas water heater or vent r 1.50 F W . Swke+i Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Plans Parcel Declaration Parcel Map 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 Bld�'PiSs e�}7-c � Parcel Approval Plans Approval Lawn sprinkler 2.00 s P y NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ❑-- Permit•Fee $ •®a $ o0 /NS%f�LL Jqs I-IAJ E(.,ee_% ELECTRICAL No. @ FEE TO �� Tq� `-•� PERMIT FILING FEE $3.00 tQO Main service 600v OR LESS 100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER e O 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW OR ADDNST ( ACCLBLDGS.LING OCCUP. Y) 20sgft CONTRACTORS LICENSE LAW 1 am licensed under the provisions of Chapter 9, Div. 3, of 'the State of California Business & Professions Code under the name style of: j / /, r NEW CONSTR. BRANCH CIR T NON -R ESI D. BRANCH CIRCUITS) 2.50ea NEW CONSTR. (POWER APPARATUS 0 NON.RESID. SINGLE OUTLET CIR. Ex. OCCUD(OUTLETS OR FIXTIIRES) B L @251Co FIED APPLNS. OR EX. OCCup. OUXTLETS (RESID.) EA) 200 Temporary service 10.00 r Mobile Home Facilities 15.00 -®O IN/�s i License No. [ Classification Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ -00 $ bG WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. - ve placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ % Oe autho ize re esentatives of the County of Butte to enter upon the abov -menti ed prop rty fo inspection purposes. ie Date Si azure ofPermitee or Agent fP Receipt No. ✓ 47 S"Z-- White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of e utte County Code and/or resolutions to do work indicated XE OR OF PUBLIC WORKS � Date 74 ' 7f Building permit expires Date _ 12--41-,90 COUNTY OF BUTTE Department of Public Works 7 County Center Drive Oroville ----- 534-4541 ELECTRICAL INFORMATION FOR DE -RATING MOBILEHOMES Owner ow O'C1111, to—,, z r-0-4 Location 6 � 4.0t % Mobilehome Installation Permit No. FILL IN INFORMATION FOR ITEMS 1 THRU 10 Watts 1. Width. : '� x Box Length f'1 x 3 2. 2 Kitchen Appliance Circuits .... = 3,000 3. 1 Laundry Circuit ........ = 1,500 4. Ovens .. .. ....... .. ..... 5. Cook Stove Top ............................... _ 6. 'Hot Water Heater ......... .......... _ 7. Dishwasher & Disposal = 8. Clothes Dryer ... too, - 9. Other (specify, i.e., motors, exhaust fans, etc.) Sub -total -Watts ..... ' First 10,000 watts @ 100% = 10,000 yy Remaining �t1 watts@ 40'/0 ..................... a10. ns @100'/0.. Largest Demand = a o X Central Heat System . ' watts @ 65%.. _ iJsit ) TOTAL DEMAND WATTS REQUIRED i "Demand Watts Required" 230 ..... .... = vJ .AMPS De -rate Mobilehome to ......... AMPS BUTTE COUNTY BUILDING DEPARTMENT A PP E COUNTY OF BUTTE,. - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 . Teleph9ne:534-,4541 � APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the aboveentioned property for inspection purposes. K / Signature f Permitee or Agent Receipt No. ��q� White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above hich fees have been paid. 7D EC PUB WORKS By ate -//-/-3 Building permit expires Date BUILDING Owner �kOZ PlLl:�J-_.] SQ. FT. OCC. BUILDING VALUATION 4 Mailing Address /� j I 29-0 d i/`r leo Looe" L>rL9�-' "�I�6 Contractor Z, nl &b� V1Lh+0,: 0 1 Mailing Address a.L,tX L,,A 6CrA_ Fireplace Total Valuation _ CLJY VC's IJ' LL& f� / L.3 neN a�ae�a4 7`5 7 Permit Fee Building Address ��b, ��� Plan Checking Fee&/or Penalty Permit Fee PLUMBING No. @ FEE PERMIT FILING FEE $3.00 Each Trap 1,50 Q 200, 00 L -LZ Repair drainage or vent piping 1.50 A. P. No. 3 5 " 214- z- 1j('.4�1 y Coning`$. Planning Water piping 1.50 Each gas water heater or vent 1.50" s W `i�J'" on Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Plans Parcel Declaration Parcel Map 60' R/W Impro nts Each additional outlet .30 Building sewer 5.00 Bldg. P ns Recd I Parcel A oval ans Approval Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER Permit Fee $ $ FpIZ ELECTRICAL No. @ FEE 61 T -E PERMIT FILING FEE $3.00 Main service eooV OR LESS 100 AMP OR LESS 5.00 Single Family ❑ Duplex Mobil Home Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER 600V 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 OR ADDNST % ACCLBLDGS COUP. 7i1 •2P Sq ft /\ CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business &Professions Code under .the name y � _ ��� / � st I of: % / f 'L/1A` 2� N6 1-(u / LI � C l >N t!::S NEW CONSTR BRANCH CIR T NON-RESID. ( BRANCH CIRCUITS/ 2.50ea NEW CONSTR. POWER APPARATUS B NON-RESIDI. SINGLE OUTLET CIR. Ex. OCcUp{OUTLETS OR FIXTtIRES 50 t?B¢ � BAL@lOs APPLNS, OR Ex. Occup. OUTLETS (RESID.) EA) 2.00 p (OUTLETS Temporary service 10.00 Mobile Home Facilities 15.00 License No. ��b.7`l.rl Classification - I Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ E77 - WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. f1' I have placed on file with the County of Butte a certificate of J� Workmen's Compensation Insurance. ❑I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE - $3.00 Heating Cooling Ventilation Ha Hood Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby L ee 40P00 $ 4-0. 0Z TOTAL PERMIT FEE $ -+u OC authorize representatives of the County of Butte to enter upon the aboveentioned property for inspection purposes. K / Signature f Permitee or Agent Receipt No. ��q� White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above hich fees have been paid. 7D EC PUB WORKS By ate -//-/-3 Building permit expires Date NOTES t- b n a„ 3j ... w w ..wr tr' w. : °•^�CCOrf�iy; rl!`(� i�Shall �Ynshin `W�P �s < <' Y. y / , !. a. N T hi : ° - ,.; , ,t fr•' of c! gtt/'+Prt,r •rrR^,f�•.i4, f - Abri Frac -ices and } k. �n.,.UnIF f / SPC'r1r10d USG-' in fl c ryY } rib fir. Pr�irihy rrrt�. i, r } F' �% rcinc�l A I "y' Iviuclinnicctl Codes and i t' r�' tit �'�at L'f f IGQI OC1@�, ' t , 1 Y�; � +. WMiMMYw rA f. `\d�O.M Wli�06+rt!.u. t ,..11.:1-b W #• yt 1{ ,t ! r 1. A'w.. �.. r t Y t / J\7t n].�y.'} :i QMH .� •"iii u�. _ y rr , . i. �: ; ••.�{•L �! < h { r�' ♦,+ � - j t.... ty''. '` r y S `�Lii /�I l+tt+l '1 r 1 .ar.' .t S• i . N •'r. L �. j �sl� h r his.. set t'� plans a�.�t�a:�esals Nrv51- b. }: 7 N nepi an tf�e b 'af API tirli�; anr.i it is ur,la r�fv) to s !. >• �,• ° crake any clic; ges dr alleratians on' same without writfen' permis_ n from` the UEraar;rn fit of .I7ubPir. t �,• t; i d4. Works. County. f .Butte. �. -xt ; ., �ii?o►?i�s� r.7 2 X!S7�nd� ry d r ..,r i�?y €V'}"(,,... - ...?: rrV � 6 � Y'l.'`t�` l-_`, �.y'���-wd'` !! ••y.' �.� - � � i� '0 S' w JG JY A t t t f - ' 1 1 '• • i i f. BUTTE COUNTY+.* co 4klplta.I� - .. 17bsr� r-r7t BUILDING P��f�TM�Nl M 7Qhn Sid �Y•9•r•. Ylnr�V �9r>� Cii ir•i T� •{rte ixls' cenle rlinc. {?F j'11f' C�t.'� ran TII ! Itr)%i t . . ��:�s� /IPPR VSD m or 6 2 ft. eu%,e overhrn7.. ' .7 � wb r �+' t e � !! f' 't .• + t,: t.i ( i. ' / ' • t.' :S;-.7.,j� � , N/��..��G .. l lS 1.<,>".T�'d C1Y •_ . i J�.� '� ` •��� f Lv 14 K +,1 t: �� ra pt, ,r a.S'A i~� >til 10, t =ejlirT i- �' 4 BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS - 7 County Center Drive, Oroville, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 1. Owner's name: -- - � — ®RUIL— 2.. Installer's name:_ 3. Is*the site currently under permit? Yes / / No (If yes, furnish permit number ) OR Is the site an existing site? Yes / No 1..3}P (If yes, furnish two.(2) plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes / / No (If no, clarify ) 5. What is the mobilehome electrical rating? ----------------------- Amps What is the mobilehome site service rating? --------------------- �U6. Amps 7. What is the mobilehome site circuit breaker rating? ------------- Ja Amps 8. Is there any other electric load to be served by the mobilehome t site service? --------------------------------------------------- Yes / / No =27 (If yes, identify the load and size: (Load) (Amps) 9. What --- is the mobilehome site gas pipe size. ----------------- 10. 10. What is the type of gas service? ----------------------------- Natural LPG . r 11. What is the gas pipe length from meter or tank to the mobilehome? 12. :What is the mobilehome gas demand? ------------------------------ (BTU) (This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) 1..3}P MOBIDEHOME SUPPORT DATA VR If other than single wide, Mobilehome Mfr, furnish Setup Model No. c3 /_ ' Year, Width - (ft.) Box Length '> (ft) :Tagalong :.or Expando Size ft. "x fit. (SHOW SUPPORT DETAILS'BELOW).''' On all mobilehomes manufactured after October 7, . 1973,t furnish manufacturer's installation manual and structural setup sheets'X if .not on, file.,*i-th the County of Butte) . All center supports measured from front of ` mobilehome unless otherwise specified: -; 4 Footings (check one) ' Single 1. Wood either ' hA pressure treated ox foundation grade. Ax (ft.)(in:) (in.) (in.) 2. Other (specify) Center support Center support locations* footing -sizes Supports (check one) (in.) 1: Concrete block. ' 2:. Other (specify) (ft.)(in,) (in.) (in.) (----Tagalongi,or Expando,' show support details. (ft.)(in.)- (in.) '(in:) "3 1o2x�0 -- _Typical Support (in.) (in.) Footing Size_ 13 11x• Max. Pier Spacing_ Max. Overhang i (ft.) (in.) (ft.) (in. ) an BUTTE COUNTY BUILDING DEPARTMENT APPROVED *If center piers are other than drawn above, draw in --locations, spacing, and dimensions.., `iPERM1T NO. P 4. a �E •'M MH UTIL. PERMIT NO. 2988-74P.E ' PERMIT EXPIRES ;OWNER George Jacobs �c iCONTR. h. ,—LOCATION (A.P. 35-214-2 4529 Baggett Rd, Oroville r �4 Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Temp. Gas Serv. Called PG&E /FINALED (Date) (Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING I BUILDING (C*ont'd) I PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Pipingr Piers Roofing Sewer Garage Fdn: Vents Fixtures Footings Garage Vents Water Htr. Stemwall Slab Prov. for physically handicapped Heaters Appliances Carport Footings Conformance of ex. structure Gas Piping & Test — Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing 1 ELECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Under round Interior Lath Ventilation Permanent .� Door Closer Final Final DATE REMARKS OR CORRECTIONS e GotlTir✓v,�i7o�✓ � _ , / E5e-/ST7/UG /Pe�,O&VMN?Y QF & TE DEPARTMENT OF PUBLIC WOR _7— 57 7 County Center Drive`- Oroville, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT auuwiice reNreSenjail ves of the County of butte to enter upon the above-mentioned property for inspection purposes. w X Date gnature f Perm tee or Agent �] 6 // Receipt'No. /A2, White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR Of)PUBLIC WORKS BY Date —1 y— wilding permit expires Date ................... 7..% BUILDING OwneraGp 16 16Mailing SQ. FT. OCC. BUILDING VALUATION Address Telephone No. Fireplace Contractor Total Valuation Mai I ing Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee $ $ Building Address eVJ PLUMBING No. @ FEE PERMIT FILING FEE $2.00 a Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. 2_1 v%7 -a- Zoni n F ire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Building sewer 5.00 EQA Parking Parcelparcel Plans Declaration Ma 60' R/W Im rovements P Lawn sprinkler system 2.00 Bldg. Pla0j c'd Parcel tyroval PIApproval Permit Fee $ $ NEW ADDITION ❑ UTILITIESX OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service incl. 1 meter ,Q Additional meters, each 1.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Sub -panel (12 or less) (more than 12) Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures bal 610 Receps., switches & fix outlets 2u 25 CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp. or D.W. 1.00 Air conditioner or heat pump Water pump Mobil Home Facilities 5.00 Temp. Power Pole 5.00 License No. Classification Misc. wiring 01 am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ TOTAL PERMIT FEE $ auuwiice reNreSenjail ves of the County of butte to enter upon the above-mentioned property for inspection purposes. w X Date gnature f Perm tee or Agent �] 6 // Receipt'No. /A2, White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR Of)PUBLIC WORKS BY Date —1 y— wilding permit expires Date ................... 7..% ,PERMIT NO. 4279-76B PERMIT EXPIRES a ;OWNER Wayne Anderson CONTR. Acro -Lune, Oroville LOCATION (A.P. 35-.214-2 4529:IIarysville-Bagget Rd., OroviIle I, ,I t; a. $t t �v! 4 - Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E s Temp. Gas Serv. ` Ca'lled PG&E ' o is z1_FINALED (Dat ) j (Signature) 4 \ COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING' Setback �''�ZZ� ��' Firewall Soil Pip'n Forms Parapets 1st FI or Main Bldg. Restroom Finish. 2nd FI or Footings Windows 3rd Flo r Stemwall Siding To out Slab Roof Sheathing Water PiDi Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings Garage Vents Water Htr. Stemwal l Insulation Heaters Slab Prov. for physically Appliances Car ort handicapped p Conformance of ex. Gas Piping &Test Footings' structure Temp. Gas Slab f Final-/ �Z Sanitation Patio /` FIREPLACE Final Footings Z ? Footing E ECTRICAL Masonry Walls i Throat Rough Reinf. Steel i Final Fixtures Bond Beam, FIR S INKLERS Motors Framing V— /12 Test Water Htr. Stucco Final V Subpanels Mesh MIACHANICAL Grd. Fault Pr t. Scratch Heatinq Service Brown Cooling Temp. Pole Finish Ducts Under ro nd Interior Lath Ventilation Permane t Door Closer A Final Final DATE REMARKS O CORRECTIONS V l (NOTE: An entry must be made on this form each time you visit the job site.) T COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS / 7 County Center Drive — 0 oviIle, ;alifornia 95965 Telephq;.e: 534.4541 ttt[[[JJJ APPLICATION AND PERMIT BUILDING Owner A VkJ_ �1 _>ZS� SQ. FT. OCC. BUILDING VALUATION Mailing Address Telephone No. Contractor At T20 _ Mai I i ng Address -T-.3 Building Address L i A v C Telephone No. 1 LLQ . 3'33—(7a i A. P. No. Zoning & Planning Fees W.C. FireDept. FireZone Use Permit EQA I Parking I Parcel Parcel Ma 60' R/W I Im r Plans Declaration P p ovements Bldg. Plans Rec'd Parcel Approval ] PI&Ils-Approval NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ Single Family ❑ / Duplex s❑ Mobil/Home ❑C Others ❑ %,?,tC/ (/ (D / Y rX o / /y (1 ,li / AI u . CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: / W,: License No.o� %q S q 7 Classification Fireplace Total Valuation Permit Fee Plan Checking Fee &/or Penalty Permit Fee PLUMBING PERMIT FILING FEE Each Trap Repair drainage or vent piping Water piping Each gas water heater or vent Gas piping system 1 - 5 outlets Each additional outlet Building sewer Lawn sprinkler system Permit Fee ELECTRICAL PERMIT FILING FEE Main service incl. 1 meter Additional meters, each SUb-panel (12 or less) (more than 12) Ranqe, Cook -top or Oven Water Heater or Space Heater Light fixtures Receps., switches & fix outlets Hood, Ex. Fan or F.A. Furn. Motor Evap. cooler, gar, disp. or D.W. Air conditioner or heat pump Water pump Mobil Home Facilities Temp. Power Pole Misc. wirinq ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee MECHANICAL: WORKMEN'S COMPENSATION INSURANCE PERMIT FILING FEE 1 am aware of the provisions of Section3700 of the California Labor Heating Code which requires every employer to be insured against liability for Workmen's Compensation. I have placed on file with the County of Butte a certificate of Cooling Workmen's Compensation Insurance. I certify that in the performance of the work for which this Ventilation permit ,is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of Hood California. Permit Fee I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned pr er for inspection purposes. X Date7— Signature r eerc/mitee/or Agent Receipt No. �`y/�v White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant FEE $3.00 1.50 1.50 1.50 1.50 1.50 .30 5.00 2.00 2.00 TOTAL PERMIT FEE $_1�1_ This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF BLIC WORKS By Date c%��7, 7 tiding permit expires Date P-2--7 7 Return to DPW AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT RL GORD-E0 BUTTE COUNT.Y, FOR RESIDENTIAL DEVELOPMENT OFFICIAL RECORDS BY Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. 87!.- „7y 6454 1987 FEB 18 Pith 2: 49 The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this CANDACE J. GRUBBS property may be subject to inconveniences or discomfort arising from �P�1�� the use of agricultural chemicals, including, but not limited. to herbiccM,,R B¢ e and fertilizers; and from the pursuit of agricultural operations including, but.not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or disconform from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described - - as follows: Lotsy3 and 4 according to that certain map entitled, "Official Map of the Baggett Tract, near Oroville, Butte County California, which map was filed in the office of the Recorder of the County of Butte, State of California June 14, 1909 in Book 6 of Maps, at page 83 • Date: PROPERTYOWNER r � State of Owl FogpJiA ) On this the h day of e,6i2V!JR 19 9' before SS. me, the undersigned Notary Public, personally appeared _• County of .&IA's ) 6eelkle 3A 0OA9 4V NOT COMPARED *I H 0*R11G;1NAL DOCUMENT / ■ ■ / Personally known to me. J Proved to me on the basis • RICHaARDFEUERSTEM — of satisfactory evidence. r NOTARYpALIFORNIA Bum county � to be the person(s) whose names) A”subscribed to mm s �yco.wionExpl�resAn. a41,'ON O� the within instrument and acknowledged that 7f�Y ■ N ■o ■■■■■■■■■■■■■■■/■move■ g executed the same for the purposes therein contained. n/■■■■ ■■■/■/■//■ ■■■■■■/■■ SIN WITNESS WHEREOF, I hereunto set my hand and official seal. i RICHARD FMMTEIN ■ ■■ ■ NOTARY PUBLIC -CALIFORNIA UP / Butte County r / My commission Expkw Jen. 24, 190 / ■ ,a/'J•/■■■/r■�■■■■a�//■■■■/s� �1 Notary Public Present A.P. No. 87-06454 Return to DPW AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT RECORDED BUTTE COUNTY FOR RESIDENTIAL DEVELOPMENT OFFICIAL RECORDS BY Section 26-8.1 of the Butte County Code requires this acknowledgement 1•PART f SHMN be recorded prior to issuance of a building permit. 87- 6454 1981 FEB 18 Pi 2:9 The property described herein is adjacent to land or included CANDACE J:.GRUBBS within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort arising from CLERK -RECORDER FES the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust �.... smoke, noise, and odor. Butte County has established agricultural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or disconform from normalragas . necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: - Lots 3 and 4 according to that certain map entitled, "Official Map of the Baggett Tract, near Oroville, Butte County California, which map was filed in the office of the Recorder of the County of Butte, State of California June 14, 1909 in Book 6 of Maps, at page 83. Date: r!` v PROPERTY OWNER State of (2A)1 f01?PIJ1A ) pp ) SS. County of -&Me ) On this me, the &V s the day of _re,G2uA�f� 19�, before undersigned Notary Public, p sonally appeared !AIA JA_ CohS ®aoa■■oo■■■■■■o■■■■■o■a■■13 _ a RICHAR®FEUERNS4TEIN p L / Personally known to me. / / Proved to me on the basis ■ of satisfactory evidence. a NOTARY PUBLIC -CALIFORNIA ■ r -0 a Butfecounty o to be the person(s) whose names) IOP subscribed to My CommissionLxpiMsJan. 24,1889 a the within instrument and acknowledged that so. ,' ■s■■■o■■■■■■■■■oo■■a■■®■ ® executed the same for the purposes therein,eontained. means-na■■■Baseman Dan soon ■BIN WITNESS WHEREOF, I hereunto set my hand.t,`andofficial seal. n RICHARD FEUERSTEIN P ■ NOTARY PUBLIC -CALIFORNIA ~ `� e Butte county ■ ' ■ My Commission Expires Jan. 24,' 1899 ■ ■ ®o�1■etto■■oa■■■■m■00000ea®off Notary Public Present A.P. No. 9�NVD Q �QCUMEN� �o6*10 . tip r. , k Al ... I` ,. . {'t'T y J•; ',/ lJ : A V �r:�' ��; r1 � L o w s i dor GOO e. I Ill esn PCI100cis L��, ..0 I PIUt7O C,w7,�141� N ti "13'�j"d'a all of uo 54bt ai�t 10 Scabvl -3v: R!i✓"a �' ��) 4f' �CIO 17 % Lit 40 M I Y3^sc 1$4n &V Oct va Y'7 VA r 0 tv X <70 b& ry la "7 (vo )J -u 7£✓_G-p 5 r I 3 tat p 1 31 ('9 CJ