Loading...
HomeMy WebLinkAbout035-420-005-'as` �' _ � '��. � F .. � li � _ �. -`« ' �,� � , - .� �_ i !: � � °t' , Ln �� PERMIT NO. 3866-79B,P,E,M PERMIT EXPIRES a v OWNER Sunbeatn Const. Co. CONTR.- owner +� LOCATION (A.P. 5294,Margo Lane, lot 121, Crestwood Sub#2, Oroville r r ( Temp. Power Pole Called PG&E Temp. Elea Se/r11 .�2�' ill Called PG&E Temp.,,��Gas Serv. `G Cdlled PG&E �% 3 OB tf d FINALED - / L (Date) (SignaturOl 5°�ti.- Setback Forms Main BI Footi )('Framir Stucco COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD S1 -7v'79 c. Water Piping Sewer Gas Piping ILE OME INSTALLATION - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping l49 DATE REMARKS OR CORRECTIONS r �w ' C (NOTE: An entry must be made on this form each time you vislt the job site.) P L U M B I N G Check List �rmit YUnde loor Stae D.W.V.: (1) Sizing. "(2) Materials. (3) Fittings. (4) Grade & Support. (5) Cleanouts & Accessibility. (6) Clearances. (7) Rough -in Locations. (8) Wrapping. (9) Test - including "Ts".. (10) Additional test not required.* Water: (1)Sizing. (2)- Materials. (3) Support. (4) Test. (5) Wrapping. E] (6) Dissimilar metals. (7) Service regulator installed or not required.* Gas: (1) Sizing. (2) Materials. (3) Support. (4) Log Lighter. (5) Wrapping. 13/Fram' S tae To Out D.W.V:: (1) Size. (2) Vent Area & Termination. (3) Materials. (4) Fittings. (5) Grade`& Support. (6) Cleanouts. (7) Traps. (8) Nail Protection. (9) Plumbing Access. (10) Toilet Clearances. (11) Shower size. (12) Shower Pan Test. (13) Vents - turns, horiz., runs, loop, wet,*etc. ❑* (14) Additional 2nd floor test not required.* Water: (1) Pipe Test. (2) Mixer Valves. (3) Support. .(4) Roof drains. Gas: (1) Size. (2) Materials. (3)'PR Valve Drain. Water Heater: (1) Vent. (2.)..Location, (3).PR Valve Drain. Final 6/0 D.W.V.: (1) Connected to sewer system. (}--Special systems. EWater: (1) Water Source. (2) Shut-off. menti -siphon Valves. Gas.: (1) Test. (2) Connectors. Water Heater: (1) Location. (2) Accessibility. (3) Clearances. (4) Stability. (5) 18" Garage Floor. (6) Mechanical protection. (7) Combustion Air. (8) Draft Diverter. (9) Vent Connector. (10) Vent. (11) Shut-off and connector. (12) PR Valve & Drain. Fixtures: (1) Approved. (2) Stability. (3) Clearances. (4) Trapped. (5) Connections. (6) Cross -connections. (7) Dishwasher Air Gap. M E C H A N I C A L Check List • B-21 ermit Underfloor Stage ' Underfloor Supply Plenum: (1) One-story. (2) Clearances. (3) Combustible material.'(4) Insulation and vapor barrier. (5) Access. (6) Catch receptacles and registers.,(7) Fire -stopping. (8) Boots. (9) Supply ducts. (10) Gas lines and plumbing'cleanouts. Q Ducts: (1) Size. (2)Materials. (3) Support. (4) Fittings. (5) Wrapping. (6) Insulation. (7) Clearances - ground, crawlspace, cleanouts, plumbing, etc. El Combustion Air: (1) Size. Q Refrigerant Piping: (1.) Material., (2) Support. (3) Fittings. (4) Insulation. ��rami Sta e Heating: (1) Approved appliances. (2) Accessibility. (3) Clearances. (4) Combustion air. Q,Vent and Connector:'•,(1)Approved. (2) Size. (3) Clearances. (4) Cap. (5) Termination. Ducts: (1) Materials. (2) Size. (3) Support. (4) Fittings. (5) Insulation., (6) Fire Damper. ❑ Refrigerant Piping: (1) Material, (2) Support. (3) Fittings. (4) Insulation. (5) Condensate drain. F ina l �Il Ieating: (1) Accessibility. (2) Combustion air. (3) Safety controls. (4) Electrical connection. (5) Fuel shut-off.. �o�lin: (1) Accessibility. (2) Support.. (3)•.Controls. (4) Pressure relief valves..(5)_Class 2 refrigerant. 5/79 Permit# INSULATION CERTIFICATION Oroville Num . t,er and Street City county Crestwood Sub lot 121 Subdivision Lot Number DESCRIPTION OF INSTALLATION ROOF Material Brand Name Thickness (inches) Thermal Resistance IR Value) EXTERIOR WALL Material Fiberglass Brand Name Certainteed Thickness (inches) 3�11 Thermal Resistance (R Value) 11 CEILING Batt or Blanket Type Brand Name Thickness (inches) Thermal Resistance (R Value) Loose Fill Type Fiberglass Brand Name Certainteed Minimum Thickness (inches) 1111 Number of bags 22 Weight per bag lb 2 Area Covered (ft 1 1140 Thermal Resistance (R Value) 25 FLOOR, ELEVATED .1 Material Brand Name Thickness (inches) Thermal Resistance (R Value) FLOOR, SLAB Material Brand Name Thickness (inches) Thermal Resistance (R Value) Width (inches) FOUNDATION WALL Material Brand Name Thickness (inches) Thermal Resistance (R Value) HEATING SYSTEM Gas Furnace Make Model Description Rated Bonnet Capacity DECLARATION I hereby certify that the above insulation was installed in the hu;lciing at the above locat;on in conformance with the current regulations setting Energy Conservation Standards for new rpsidenlial buildings (located in Title 24 of the California Administrative Code). "`BEAM CONSTRUCTION CO.-� UMSE #15326-6 General Contractor (Builder,) License Number < Signature i"rid-Tille oaf'* T. VISMCA Hawkins Insula i -InC. 378407 t1on onliactor (InE�It. )2��C a n Applicator) License Number 2-4-80 Sigoature and Tli-li Date CERTIFICATE REVIEWED BY Date BIN -029 —(B—Lt-i'l Tiny; g In s p fes) i c e I H t RESIDENTIAL' ENERGY CONSERVATION STANDARDS CONSTRUCTION COMPLIANCE CERTIFICATE THIS IS TO CERTIFY THAT ENERGY CONSERVATION REQUIREMENTS HAVE BEEN INSTALLED IN CONFORMANCE WITH CURRENT ENERGY CONSERVATION REGULATIONS AT .40 T e Z-/ (5126 (location) BUILDING PERMIT NO. A;P. NO. THE FOLLOWING HAVE BEEN INSTALLED AS PER APPROVED PLANS: (Check each item or write N/A if not applicable) INSULATION: Slab Edge. Fdn..Walls Floors -- -- Walls Ceiling/Roof /?-/�Q_ Ducts CirculatingTip-es APPROVED HEATER__` APPROVED WTR.HTR. ,. GLAZING: Single Glazed Special (Insulated)�,r� CERT. & LABELED WDS. & SLIDING DRS. WEATHERSTRIPPED DRS. BACK DAMPERED FANS INTERMITTENT IGNITION DINICES ' CERT. APPLIANCES I DECLARE THAT ALL REQUIRED ITEMS AS NOTED ABOVE HAVE BEEN INSTALLED IN ACCORDANCE WITH THE ENERGY CONSERVATION REQUIREMENTS AND AGREE TO THE COMPLETENESS OF THIS CERTIFICATE AS SUBMITTED. Insulation Applicator Name Signature of (please print) Insulation Applicator State Contractors License No. General ro-trac^r/Owner Name (please print) Signature of r/Owne �� Date G ref �O State Contractors License No. THIS CERTIFICATE MUST BE ON FILE WITH THE BUILDING DEPARTMENT PRIOR TO REQUESTING FINAL INSPECTION AND SHALL BE POSTED IN A CONSPICUOUS LOCATION WITHIN THE DWELLING. COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive — Oroville, California 95965 � Telephone: 534-4541 /,, _ APPLICATION` AND PERMIT ��`� Receipt No. GKu/ �5 4 v v _ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant Building permit expires Date BUILDING Owner C�� 5 % SO. FT. OCC. BUILDING VALUATI Mai I i ng Address 6� $ cr% 405, G'-" LL z? Telejhone No. es 2Y - bYg Contractor Mailing Address Fireplace Total Valuation S ,Q(3 Telephone No. Permit Fee Building Address {�L�-O Plan Checking Fee&/or Penalty Permit Fee (� PLUMBING No.1 @ FEE PERMIT FILING FEE $3.00 a,crO Each Trap 1.50 4/ga-t✓ Ler Repair drainage or vent piping 1.50 A. P. No. _ �� vs� `oning P anning Water piping 1.50 Each gas water heater or vent 1.50 Fees /J we, n Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 Parking EOA Plans ParcelEach Declaration 60' R/W Improvements additional outlet .30 Building sewer 5.00 Idg. s Rec'd P a r c ell"A"p p rovaI Plan royal Lawn sprinkler system 2.00 NEWru ADDITION ❑ UTILITIES ❑ OTHER ❑ Permit Fee $ . $ ' 4`VVY 'w) ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service 100 AMP O00V OR RSLess 5.00 Single Family Duplex ❑ Mobil Home ❑ Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER e00v 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW CONST. (DW • C. 4') 20 sq ft `S OR ADDNS. A S. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW NON .CONSTBRIS L I-OUTL T .CONS ANCH CIRCUITS) 12.50ea NEW CONSTR. (POWER APPARATUS.&J NON.RESID. (SINGLE OUTLET CIR. Ex. Occuo(OUTLETS OR FIXT11RE5 a �@ FIXED APPLN9. Ex. Occup.(OUTLETS ((RESID )REA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No. Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ ,`L S $ S MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor which requires every employer to be insured against liability for Workmen's Compensation.% ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE J$3.00 Heating�q 1.0c)Code CSN S Cooling Ventilation Hood 2.00 ��O Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 00 Date �S' ignature of Perm1 ee or Agent _ Land Development Fee $ QC TOTAL PERMIT FEE$ d �� This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated abo r which fees have been paid. PUB IC WORKS B Date Receipt No. GKu/ �5 4 v v _ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant Building permit expires Date This set of plans and spe ifications MUST .beG'S, 00 kept on the job at all times and it is unlawful tq mek® arty changes, or alterat ons on same `withoul written permission from the Department of Pub. Iic Works, County of Butte ' '� � '•,� 120 _o See Master Plari on f116 for Cgpct Plans. IN. VA Al AL AAA � - 4 `%e Bldg, Aft t from th BUT% COUNTY side propert �e and centerline of the end. P ng a s - �V��•I`� rrrl'' B. ILDING DEPARTMENT mum of a 2 ft. eav overhan ut a �rr7 �, c out of all Basemen s. APPROVED d -I . WO rIYO00 I AWN 49MOVIUS 5U%TE CO., CALIF 17 /!A RESIDENTIAL PLAN CHECKING GUIDE (S.F., DUPLEX, & MISC. ONLY) _ "j gav 9 , w• " OWNER (3Bldg. Permit �� / �� 4A� i9•. A. P. # 36 A. GENERAL Zoning requirements.(sideyards and parking). Valuation. ignature by R.C.E. or Architect (if required)., B. PLOT PLAN 1. Complete parcel size and dimensions. 22 `Setbackq, sideyards, easements, etc. .Other buildings or structures. Grading, fills, drainage. C FLOAR PLAN omplete to scale plan with dimensions. Required windows for light and ventilation (Sec. 1405). 3f Required windows for second exit (Sec. 1404). Allowable glazing for energy requirements (20% max. per.State law). $00man impact glass (Sec. 5406). 7�equired room sizes, ceiling heights (Sec. 1407). .F.C.I.'s in baths and exterior outlets (Sec. 210-8). 8! Light fixtures, switches, receptacles, and exterior receptacles for maintenance of /mechanical equipment. 1. Locations of water heater, heating & cooling equipment', other electrical or gas . equipment, and plumbing fixtures. O1Garage firewall, door size, and closer (Sec. 503(d)(4)). 11 - 3'0" exterior exit door (Sec. 3303d)'. 1 Fireplace location. 1y. Smoke detectors (Sec. 1413). D. STRUCTURAL DETAILS foundation plan complete enough to construct building. 2. Floor construction details complete enough to construct building. V,Elevations and wall construction details complete enough to construct 4! Roof construction details complete enough to construct building. /. fireplace construction details and calcs if over one-story in height. 6� Sufficient data and details to satisfy energy insulation requirements E. MISCELLANEOUS ITEMS TO LOOK OUT FOR jo#.*"',CCX plywood on.exposed locations and overhangs. Stairway details (Sec. 3305). 3viardrail details (Sec. 1716) 4� rick or stone veneer (Chapter -30). eVxterior plaster - weep screeds (Sec. 4706 & 4708). Proper roof pitch for roof covering (Chapter 32). �"Rafter ties or bearing ridge beam. Garage door•or porch header sizes. ;. Adequate bracing. building. (State law). 1� Living area over garage - complete 1 -hour separation required including supporting cells and posts, etc. Two (2) exits on three-story dwellings (Sec. 3302).