Loading...
HomeMy WebLinkAbout035-420-02735-42-27 Surbeam Const Co. 5341 Becky Lane, lot 116, Crestwood Sub#2, Oroville Permit #3986-80B,P,E,M(new single family) G' 4 . i r ar t� G, ti - .r+ 35-42-27 Surbeam Const Co. 5341 Becky Lane, lot 116, Crestwood Sub#2, Oroville Permit #3986-80B,P,E,M(new single family) PEiwT NO. 3986-80B,P,E.,M PERMIT EXPIRES _ OWNER Sunbeam Const.Co. owner. fONTR. 35-42-27 LOCATION (A.P. ) % 5341 Becky Lane, lot 116, CrestwoodSubl2, Oroville .' > 'i f µ_ 1 A� o • ,r Temp. Power Pole �.� Called PG&E Temp..Elec. Serv. 11Z7 �D Called PG&E ` Temp. Gas Serv. Called PG&E w JOB FINALED r, (Date) (Signa e) Setback Forms 7 Main Bldg. Footings StemwaI l Slab Piers Garage Footings Stemwa I I Slab COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD AtflLDI�IG �. BUILDIIJG (Cgnt'd) PLUMBING Firewall Parapets Restroom Finish Windows Siding Roof Sheathin Roofing Fdn. Vents `-- Garage Vents Insulation Prov. for ph sica ly handicaDDed Conformance of ex. SolI Piping 1st Floor 2nd Floor 3rd FI or To ou -r y//�c Water Piping— Sewer Fixtures / Water Htr. Heaters _ Appliances Gas Piping & Test Temp.'Gas P� Patio S / FAEPLACE Ina(l /l / Z �' D Footings Footing E E TRI L Masonr Walls Throat Rout 6 Reinf. Steel Final Fixtures l000,// / cS"� Bond Beam -FIRE SPRINKLERS Motors Framing d Test Water Htr. Stucco Final Subpanels Mesh MECHA ICA Gird. Fault Prot. // /2 Scratch Heating Service ft Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath ti a nent Door Closer !Tgra FIna 1r a Z MOBILEHOMEUTILITIES.------------------ Service Vec. Pedes Water Piping Sewer Gas Piping OBILEHOME INSTALLATION .............. Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS t (NOTE: An entry must be made on this form each time you visit the job site.) RESIDENTIAL ENERGY -CONSERVATION STANDARDS . CONSTRUCTION COMPLIANCE CERTIFICATE THIS IS :TO CERTIFY THAT ENERGY CONSERVATION REQUIREMENTS HAVE BEEN. INSTALLED IN CONFORMANCE WITH CURRENT.,ENERGY CONSERVATION REGULATIONS AT Lot L �' CRESTG-100DX SUBDIVISION UNIT NO 9 • (location) BUILDING PERMIT NO. 3V 8 c� A:P. N0. 3 —C-12— -)--:z THE FOLL014ING tHAVE BEEN- INSTAUED 4AS PER APPROVED. PLANS (Check each item or write N/A .if -not -applicable) INSULATION: Slab Edge. Fdn. Walls Floors Walls — Ceiling/ X Ducts x Circulating Pipes NA APPROVED HEATER X APPROVED WTR.HTR. X GLAZING: Single Glazed NA Speaial'(Insulated) X` CERT:' .&.eLABELED WDS. & SLIDING DRS. I X .WEATHER.STRIPPED DRS. NA BACK Da'IPERED FANS X INTERMITTENT IGNITION DEVICES_ CERT_; APPLIANCES X I DECLARE THAT ALL REQUIRED ITEMS ;AS NOTED, ,ABOVE HAVE BEEN INSTALLED IN ACCORDANCE WITH THE ENERGY' CONSERVATION -REQUIREMENTS AND AGREE ,TO THE COMPLETENESS OF THIS -CERTIFICATE AS'". SUBMITTED. Insulation Applicator Name SEE ATTACHED (please print) Signature of Insulation Applicator _ State. Contractors License No. TTd General Contractor/Owner' rlameSTJNBEAM CONSTR ^.'TON. COPARY, (please print)*OCT 17 1980. Signature of Dat General Contractor/Owners -� .��/'/�� Gregory T. Vistica jaes 7 State Contractors License No. 15200 THIS CERTIFICATE MUST BE ON FILE WITH THE -BUILDING DEPARTMENT PRIOR TO REQUESTING FINAL NSPECTION AND SHALI, BE POSTED IN. A CONSPICUOUS LOCATION WITHIN T11E DWELLING. 1U.'s-1DF. IT0 AL. f -'Nr -*.I,,(:',' KI:VAT'I ON SJ'AINDARDS CON` TROCTION' CUIMPLIANCE cri,,'rn--1CATI,7 I 'i.,() n-,R'vjry niAT CONSERVATfO'N UQUTREMENTS IL.%Vl--, BhI-:N (,*Ijl(l\,).,Iq*r CONSERVAT1.014 RECAILAT'JuNti (location) it,, i; n I!!(; jiI:i\,1m rr k,,O.. A. P.. NO. '1'111: 1IAVF BEEN INSTALLI-M AS PER APPROVFD PLANS: ((:Ii(,(:k cacti item or write i,I/A if not applicable) GLA Z 114C NA S clazed NA NA Sjwcial. (f11.,;k111tcd) NA F I o(I rs JV4 CERT, & 'LABELED WDS. s SLTDING DR.S. NA i. I i 11JIt, r W EATI I I-:11STRITITI'D DRS . NA_ I NA BACK DAM1111-:1i'I'D FANS-____.— — NA i-rculating Pipci;... NA__ j'(:Nl'l'[(')N DEV ICES NA AlTi.�11VI:1) NA CKR.T. A IT).- NA I DITLAPE THA'r ALL RFQIITRr.:D ITUIS AS NOTFD ABOVE HAVE BF.FN TI-ISTAL1.171) W11,11 THE ENERGY (,0sH",E'I\'V AT'JOH AND AGKI-T TO THE. OV THTS AS SUBI"ITTED. hr:id aCimi Appl ic.-it.or Name Hawkins Insulation CoI ic. Si}',Ilavllre 01, print)I(m AppLicator St:itc Contractors Licenso. No._ 378407 'Gcncral ContriccorAMicr N.-inc' CONSTRUCTIM C-0 print) Sji,,natiirc of OCT 17 Contractortovni '2� y T. %qgflCA .,i L c Con t r,,ic tor, Mconse No. PIT", '11!:,T *Rr. ON WTTI I THE I'MYLOINC DETAwrm-'Nr mnoiz ro 1`1,iAl. IN'SITC.1-10N AND ';IIAI,I. III%' IN A CONST [C1100.1. LoCAT ION 4j:TI11:! T11F. Telephone 533.2000 North Burbank Public Utility District 1960 Elgin Street OROVILLE, CALIFORNIA 95965 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION BUILDING SEWERS This verification form must be submitted to the Butte County Department of Public Works - Building Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior to final approval by Butte County of a Building or an Occupancy Permit, a copy of this verification form, signed off by North,Burbank Public Utility District, 0 must be submitted to Butte County. Applicant: y Applicant Address: Applicant Phone No.: Property Location (s): ,.;:_ , A. P. No. (s): Fees Paid: Application for service approved North Burbank Public Utility District Inspection(s) made and successful tests) observed: Location: 7— Date: North Burbank Public Utility District release to close permit: FP Date: %S� �` ® By: = OK = Not OK = Not Applicable RESIDENTIAL (Si:ng,le and Duplex) = Not Ready Date UNDERFLOOR Plans OK exce tb's Date FRAMING (Continued) ng requirements -Setbacks -E 'ements +ABr�roperty Line Firewall & Openings F g., Mal Soi -Steg -EI rnd.- 114j" Ftg. Depth . Ext. Doors -One 3' -Check Garage -3rd story, 2 exits `. Ftg., G e; S -St - / ZL' Ftg. Depth `fle -S irs; Width -Headroom -Rise -Run -Landing -Fire Protection rF ., Porches & ecks; Soils -S eel- / /" D pth g + PI ood o o verhang-Attic Vents -Rafter Outriggers to all Ma' -Blo uts W pe iding i i Veneer . SterawaTIs, G ge; St -Blo o is-Wr ppe - Stucco -Drip Screed-Fdn. Vents-Underflr. Access -7—Tiers-Fireplace Ftg.-Steel 5#r Glazing Area -Glass Protection -Skylights -Plastic D.W.V.: Fall -Fittings -Test -2 way C/0 -Sewer Test ,_;yL-Shear Walls; Nailing -Bolts ^9r Gas Pipe; Size -Anchors 4" Water Pipe; Test -Anchors -Regulator -Ser Test Electric; Underground 42rPlenums & Ducts; Clearance -Material -Support -Ins. �4Girders-Sills-Anchor Bolts -Joists -Vents -Cripples Card -BI Dat Card -BI Date Card -BI Dat Card -BI Date Card -BI Dat Card -BI Date Card -BI Date lJCard-BI - Date FIN (Plans) OK except H's Card -BI Date i and -BI Date Date UMBING (Permit) OK except q's xt. Steps -Door & Sidelight Protection -Landings smoke Detector . Water Ht.; Vent -Access -Combustion Air 3K Furnace; Vents -Clearance -Comb. Air -Connector - Ducts-DuctsProtection5.ter 1 & Anc D T -Ft & AnQAafs_NnA_PrqS0'qtLf 17 B droom Exiting 1 17. A.401%er Pan; Test, First Floorub . G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor Tub Access lec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors *9- Stairs & Rails 62— Fi eplace or Stove; Clearances -Hearth ec. Outlets at Wood Panel; Int. & Ext. Card -BI _ Date3 Card -BI Date KJt. Fixt. & Appliance; Grnd.-> Cooking Clearance Card -B Da and -BI Date H . ec. Outlets & Receptacles at Kit. bounter Date ELEC RICAL Permit OK except q's Garage Fire Door; Swing -Landing -Closer �.-X.C. Duct in Garage -Damper F'xture & Transformer Clearance -Ins. Protection Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- IMech. Protection Elec. Receptacles Spacing -Lights &Switches at Doors 7D 5K., Elec. & Mech. Equip. Listed for Location ize Boxes & No. of Conductors -Stapled E Receptacles in Garage; (G.F.I.)-RorgIex Protec. omex Installed Close to Edge of Studs & C.J. 7 nsulation-Foam-Looked in Attic es 2 uip. Ground made up w/Mech. Fasteners -Bond Gas &Water -%. uard Rails & Deck Construction -Post Appliance Circuits in Kitchen & Conductor Size r-Drai ge & Wood-EAflh Clearance r / -EbrfS,4bfeed Wire Sjae/ / ga. C or AI-A.C. Wire Size / / ga. Cu or Al Range Circ. 0 / ga. Cu en Circ. / / ga. Cu or AI, Insulat Neutral ❑Yes o .2B: --S ce-Riser Conductors & Ground -Main Disconnect . Following instld.: Drive ,- es ❑ No; Walks es ❑ No; Planter [ ❑Yes o Stu ; Brown -Finish .70.- Equip. Clearances; Panels-Motors-Mech. Equip. C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet Clothes Closet Light -Shower Light Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. Card B -I _Dat Card BI Date �. ter Well; Disconnect, Electrical, Plumbing Exterior Elec. Trim; G.F.I. Receptacle -Underground Ventilation throughout House Card B-1 Dat Card -BI Date . falass Protection Date MECHANICAL (Perrr,it) OK except q's Porrections from Previous Inspections U, sTest-Meters Tagged; Gas -Electric A Ducts: Insulation & Support ter & Sewer Connected -C/O to Grade -HD Approval a2e"Vent Fan; Exhaust above Insulation _ densate Drain & Overflow; Size & Grade $6 Energy Compliance Certificate -Other Certificates _. Furnace -_Vent; Access -Comb. Air -Return Air Vent -115V outlet -•35_►Attic Access & Platform if Furnace in Attic aCard-BI Date' J _BI Date Card -BI � Card -BI Date` Card -BI Date Date Card -BI Date Card -BI Date Card -BI Date _ Card -BI Date Card -BI Date Date FR A G(Plans) OK except N's Comments at Final: S' s; Proper Material &Anchors _ Walls Studs -Nailing, Spacing & Bracing - ound ring Walls over Girders & F_loor Nailing_____ Dr ft Stop in Walls (rat proof) _ Fire Stops; Furred Ceilings -Stairs -Chases -Tub tom. der & Beam -Size & Bearing gers-Post Caps -Anchors -Conn fig. t FtrTies oo , ra ShU ;v/_1FfTig. 40� i, E eplace Ties or Type A Flue- ace Throat 146ro trc Access size &_Romex Protection -Draft Stop -Ins. Baffles m Windows or Exiting Doors -Sill Hat. & Dimensions Garage Fire Protection Framing (NOTE: Anentry must be made each time you visit jobsite) PERMIT NO. PERMIT EXPIRES OWNER CONTR. ASSESSOR PARCEL LOCATION Temp. Power Pole_ Called PG&E Temp. Elec. Service_ Called PG&E_ Temp. Gas Service _ Cal led PG&E JOB FINALED (Date) Signature J = OK 0 = Not OK = IVotApplicable MOBILEROMES MISCELLANEOUS = Not Ready Date MOBILEHOME UTILITIES (Plans) O,K except q's 1. Zoning Requirements -Setbacks -Easements 'Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except H's 1. Zoning Requirements -Setbacks -Easements• 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors _ 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4, Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ . / Amp -Concrete _ 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ ' /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except q's 1, Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test=Regulator-Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test t Card B-1 Date Card -BI Date Card -BI Date Card -BI Date Card B-1 Date Card -BI Date Card -BI Date Card -BI Date ,t r. COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-454 APPLICATION.AND PERMIT ASSESSOR PA CEL NUMBER r ZONING BUILDING PERMIT OWNER 14e,/`''� TELEPHONE SQ. FT. OCC. , BUILDING VALUATION V ZT L4" OWNER'S MAILIN ADDRESS O ®t -�r� e s J �. t� 3 2 SAll6oCr -- ONTRACTO '5 NA TELEPHONE y Cb CONTRACTOR'S MAILING ADDRESS CONSTR CTION LENDER��"� ��' S UNKNOWN Fireplace Total Valuation $ 30,9 p --- LENDER'S MAILING A DRESS ! v•Pr`,cY sr/c v � — S4c Permit Fee $ 1367 -- ARCHITECT OR ENGINEER LICENSE NO.Plan Checking Fee $ ,3 Z.-S)o Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUIL A RESS PLUMBING PERMIT Filing Fee 3.00 Each Trap 8 2.00, �G0 Repair drainage or vent piping 2.00 Water piping 2aOc� LOT N/O. 6 SUBDIVISION/+AME % CNe c I�Ct/DOCv PARCEL MAP - Each pas water heater or vent 2.00 Z-oo Gas piping system 1 - 5 outlets Z,.00 USE OF STRUCTURE SF [r Duplex❑ Mobilehome❑ Other SPECIFY Building sewer if"CPW Lawn sprinkler system 2.00 TYPE OF WORK New[j Addition,[] Remodel❑ Utilities❑ Installation❑ Other❑ Describe work: / VV Permit Fee $ 70 00 Contractor ELECTRICAL PERMIT Filing Fee 3.00 Main service 800V OR 000 AMP ORLESS5.00 Main service EA. ADD -L too AMP 2.50 NEW CONST. DWELLING OR ADDNS. ACC. BLD ) p 20sgft .Zlep� CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) �] I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR ULT. -OUTLET 2.50 ea NON.RESID. BRANCH CIRC ITS NEW CONST R. POWER APPARATUS & NON-RESID, ( SINGLE OUTLET CIR. Ex. Occ Up(OUTLETS OR FIXTURES 50@251 BAL@10a FIXED APP LNS. OR Ex. Occup.(0UTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 6.25 Permit Fee $ ,34 10_S_ Contractor MECHANICAL PERMIT FiIingFee 3.00 WORKMEN'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate -of Consent to Self -Insure. JI I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating 40 (J 4,00 qt w Co ling LI,d 3e G0 Hood 2.00 ,�,m(> Ventilation Permit Fee $ �® Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon.the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue. against aid C99unty in o equen a of t �e-9 ranting of this permit. �liss����� X Date ? o Signature of Applicant — Owner Contractor ❑ Agent ❑r An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Land Development Fee $ 2Slwo TOTAL PERMIT FEE $ t Z� OCCUP. GROUP 3 I TYPE OF CONST, W �j/ PARCEL � PD ND SSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF P�BLIC By r PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Dat :1 Receipt NO. q/ `7 (� WNITE•D. P: W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT Qq - Telephone 533.2000 North Burbank Public Utility District 1960 Elgin Street 10ROVILLE, CALIFORNIA 95965 DISTRICT APPROVAL AND VERIFICATION OF INSPECTION 172780 BUILDING SEWERS This verification form must be submitted to the Butte County Department of Public Works ' Building. Department prior to issuance of a building or occupancy permit, whichever is applicable. Prior -to final approval by Butte County of a Building or an Occupancy Permit, a copy of.this verification form, signed off by North,Burbank Public Utility District, must be submitted to Butte County. Applicant: SUNBEAM CONSTRUCTION' CO. Applicant Address: 11190 HOOPER LANE , LOS ALTOS HILLS, -CA 94022 t Applicant Phone No.: 415-948-6482 Property Location (s): 5341 BECKY LANE, OROVILLE CRESTWOOD UNIT NO. 2, LOT 116 A. P. No. (s): 035-42-0-027-0 -" Fees Paid: $300.00 SCOR FACILITY CHARGE PAID 6/29/79 NBPUD CONNECTION FEE UNPAID Application for service approved: North Burbank AUGUST 6, 1980 Public Utility District Inspection(s) made and successful test(s) observed: Location: Date: M North Burbank Public Utility District release to close permit: Date: By: a This set, of plans and specifications MUST r * kepf'on the job. at all mimes and it is uilawful to { snake any changes dr b1ferations on Adme without. °• written permission from the Doportmont of Public . Works, County of Butte. ' NOTE:—All Mat%rials & c Am. anship Shall Be in . Recognix . Good Practices and Accordance with of a quality prescribed for th Specified use fn the Plumbing achanical Codes and - Uniform Building, the National .Electrical Co_®. Gc cvA rloA/ �/ 5 A setback of 5 ft. from the °r ; ••; •; ° ,a property lines and a setback ''• of 50ft. from the : 0 road centerline shall be clear of structures or equipment ®kC®pt Ofor a 2 ft. eave overhang. 0 Y . 20' X3.5• L. .a -� 5 S110 4- 4 CUT e CUTTO� BUTTE COUNTY BUILDING DEPAPTMENT 54 -Ey® See Master Plan on file :for building A PRIM) .R OV ID /// 90 OOf>i/< ®/7061/LLQ i�UFl� CO 017A, 1A l L04° 6Li0�, G°�L/ OlIi4/ , 9