HomeMy WebLinkAbout039-180-037CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 Project Address........ 2534 DAYTON RD. ******* --------------------- CHICO, CA. 95928 *v7.10* I I Documentation Author... BOB METZGER O.D.S. ******* I Building Permit # I Bob Metzger O.D.S. I i 2231 St. George Lane, Ste 70 I Plan Check / Date 1 Chico, CA 95926 I i 530-865-9688 I Field Check/ Date Climate Zone........... 11 / --------------------- Compliance Method...... MICROPAS7 v7,10 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -FORM CF -1R I i User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION I ------------------------------------------------------------------------------- -----------------------------=--------------------------------- - MICROPAS7 ENERGY USE SUMMARY = ---------------------------- = Energy Use Standard Proposed _ (kTDV/sf-yr) Design ---------- Design ---------- - ----------------------- Space Heating.......... 43.84 39.55 = Space Cooling.......... 72.38 69.57 = Water Heating.......... 13.14 10.13 = Total 129.36 119.25 Compliance = Margin = 4.29 = 3.01 = 10.11,"-- Building .0.11/ Building complies with Computer Performance *** *** HERS Verification Required for Compliance GENERAL INFORMATION ------------------- HERS Verification.......... Required Conditioned Floor Area..... 2262 sf .- Building Type .............. Single Family Detached Construction Type Existing+Addition+Alteration Vintage Assumptions ....... Before 1978 Fuel Type NaturalGas Building Front Orientation. Front Facing 0 deg (N) r Number of Dwelling Units... 1 Number of Building Stories. 1 WPathP r Dnta Tvne.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... V ,NJ Raised Floor-'®" \� 19097 cf 1+Pep 0 sf 16.,4 % of floor area 0.99 Btu/hr-sf-F 0.65 8.4 ft" CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 -----r r9-.-- r----------r--r9-.-r r-------.-------r..�r-.rr-----------------r-rrr-..�--- Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 ---------------------------------------------- . I MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -FORM CF -1R User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION I ------------------------------------------------------------------------------- BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo- Vent Vent Verified Area Volume Dwell Peop- it- stat Height Area Leakage or Zone Type (sf) (cf) Units le ioned Type (ft) (sf) Housewrap -------------- ----- ------ ----- ----- ------------- ----- ------- ---------- HOUSE - Existing Residence 2001 17009 0.12 0.5 Yes Setback 2.0 Standard No HOUSE - New (Added) Residence 261 2088 0.88 3.5 Yes Setback 2.0 Standard No OPAQUE SURFACES FENESTRATION SURFACES U- Sheath- Solar Appendix Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type ----- (sf) ---- or ----- R-val ----- R-val ----- Azm --- Tilt ---- --- Reference Comments --------- -------------- ------------ HOUSE - Existing 1 Wind Front (N) 40.0 1.280 1 Wall Wood 422 0.102 11 0 0 90 Yes IV.9 A3 3 Wall Wood 187 0.102 11 0 0 90 Yes IV.9 A3 4 Wall Wood 23 0.102 11 0 135 90 Yes IV.9 A3 5 Wall Wood 298 0.102 11 0 90 90 Yes IV.9 A3 8 Wall Wood 414 0.102 11 0 180 90 Yes IV.9 A3 10 Wall Wood 124 0.102 11 0 270 90 Yes IV.9 A3 11 Wall Wood 23 0.102 11 0 45 90 Yes IV.9 A3 12 Roof Wood 2001 0.076 11 0 n/a 0 Yes IV.1 Al2 14 Floor Wood 2001 0.099 0 0 n/a 0 Yes IV.20 Al 16 Door Other 17 0.500 0 0 270 90 Yes IV.5 A4 Entry HOUSE - Deleted 6 Wall Wood 189 0.102 11 0 90 90 Yes IV.9 A3 HOUSE - New (Added) 2 Wall Wood 119 0.102 13 0 0 90 Yes IV.9 A3 7 Wall Wood 174 0.102 13 0 90 90 Yes IV.9 A3 9 Wall Wood 44 0.102 13," 0 180 90 Yes IV.9 A3 13 Roof Wood 249 0.026 38/ 0 n/a 0 Yes IV.1 A8 15 Floor Wood 261 0.048 19/r 0 n/a 0 Yes IV.20 A4 FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) ----- factor ----- SHGC ----- Azm --- Tilt ---- Type -------- Location/Comments ------------------------ ------------------ HOUSE - Existing 1 Wind Front (N) 40.0 1.280 0.800 0 90 Standard F1/Existing Metal Single 2 Door Front (N) 20.0°1.250 0.800 0 90 Standard F1DR/Existing Metal Sing 4 Wind Front (N) 17.5 1.280 0.800 0 90 Standard F2/Existing Metal Single CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -FORM CF -1R I User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION i --------------------------------------------------------------- FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments ------------------ ----- ----- ----- --- ---- -------- ----------- 6 Wind Left (SE) 12.5 1.280 0.800 135 90 Standard FL1/Existing Metal Singl 7 Wind Left (E) 38.0 1.280 0.800 90 90 Standard L1/Existing Metal Single 10 Wind Back (S) 22.0 1.280 0.800 180 90 Standard Bl/Existing Metal Single 11 Door Back (S) 17.8 1.250 0.800 180 90 Standard B1DR/Existing Metal Sing 1'3 Wind Back (S) 20.0 1.280 0.800 180 90 Standard B2/Existing Metal Single 14 Wind Back (S) 38.0 1.280 0.800 180_ 90 Standard B3/Existing Metal Single 19 Wind Right (W) 9.0 1.280 0.800 270 90 Standard R1/Existing Metal Single 20 Wind Front (NE) 12.5 1.280 0.800 45 90 Standard FR1/Existing Metal Singl HOUSE - Deleted 3 Wind Front (N) 21.0 1.280 0.800 0 90 Standard F1/Existing Metal Single 8 Wind Left (E) 15.0 1.280 0.800 90 90 Standard L1/Existing Metal Single 12 Door Back (S) 17.8 1.250 0.800 180 90 Standard B1DR/Existing Metal Sing 15 Wind Back (S) 30.0 1.280 0.800 180 90 Standard B3/Existing Metal Single HOUSE - New (Added) 5 Wind Front (N) 10.0/6.300 0.250 0 90 Standard F3/Vinyl/Wood Operable 9 Wind Left (E) 16.5''0.300 0.250 90 90 Standard L2/Vinyl/Wood Operable 16 Wind Back (S) 12.0-,'0.300 0.250 180 90 Standard B4/Vinyl/Wood Operable 17 Door Back (S) 33.5/0.500 0.420 180 90 Standard B5DR/Vinyl/Wood Patio Do 18 Wind Back (S) 40.0/x.300 0.250 180 90 Standard B6/Vinyl/Wood Operable 21 Skyl Horz 12.0/0.840 0.670 0 0 None SKY.1/Vinyl/Wood Skyligh OVERHANGS ---Window--- ------------Overhang------------ Left Right Width Height Depth Height Extension Extension ----- ------ ----- ------ --------- --------- 3.2 4 Area Surface (sf) ----------- HOUSE - Existing ----- 1 Window 40.0 2 Door 20.0 4 Window 17.5 6 Window 12.5 7 Window 38.0 10 Window 22.0 11 Door 17.8 13 Window 20.0 14 Window 38.0 19 Window 9.0 20 Window 12.5 HOUSE - Deleted n/a 3 Window 21.0 8 Window 15.0 12 Door 17.8 ---Window--- ------------Overhang------------ Left Right Width Height Depth Height Extension Extension ----- ------ ----- ------ --------- --------- 3.2 4 10 1.5 n/a n/a 3.2 4 10 1.5 n/a n/a 3.5 5 8 1.5 n/a n/a 2.5 4 6.5 1.5 n/a n/a 7.5 5 3 1.5 n/a n/a 2.8 4 13.5 1.5 n/a n/a 2.8 4 13.5 1.5 n/a n/a 5 4 3.5 1.5 n/a n/a 4 4.5 3.5 1.5 n/a n/a 3 3 3.5 1.5 n/a n/a 2.5 5 6.5 1.5 n/a n/a 3.2 4 10 1.5 n/a n/a 7.5 5 3 1.5 n/a n/a 2.8 4 13.5 1.5 n/a n/a CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ---------- Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 I - MICROPAS7 v7.10 File -WHEELER Wth-CTZllS05 Program -FORM CF -1R I User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION I ------------------------------------------------------------------------------- OVERHANGS ---Window---------------Overhang------------ HVAC SYSTEMS 1 ----------- Verified Area Verified Verified Verified Verified Left Right Surface (sf) Width Height ------- Depth Height Extension --------- Extension --------- ----------- 15 Window ----- 30.0 ----- 4 4.5 ----- 3.5 ------ 1.5 n/a n/a HOUSE - New (Added) Existing Furnace 0.12 0.780 AFUE n/a n/a 5 Window 10.0 2.5 4 3.5 2.5 n/a n/a 9 Window 16.5 3 2.5 3.5 2 n/a n/a 16 Window 12.0 3 4 3.5 2 n/a n/a 17 Door 33.5 5 6.7 13.5 1.5 n/a n/a 18 Window 40.0 6 6.7 3.5 1.5 n/a n/a HVAC SYSTEMS 1 ----------- Verified HVAC SIZING Number Verified Verified Verified Verified Maximum System of Minimum Refrig Charge Adequate Fan Watt Cooling Type ------------ Systems ------- Efficiency EER ----------- ----- ------------- or TXV Airflow -------- Draw -------- Capacity -------- HOUSE - Existing (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- HOUSE - Existing Furnace 0.12 0.780 AFUE n/a n/a n/a n/a n/a ACSplit 0.12 13.00 SEER No No No No No HOUSE - New Furnace (Added) 0.88 0.800 AFUE,-n/a n/a n/a n/a n/a ACSplit 0.88 .13.00 SEER --'11.0 j' No No No No HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type ------------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- (Btu/hr) ---------- HOUSE - Existing Furnace 64583 n/a n/a n/a ACSplit n/a 32397 38850 n/a HOUSE - New (Added) Furnace 7670 n/a n/a n/a ACSplit n/a ---------- 10863 ---=------ 13027 ---------- n/a ---------- ------------- Total 72253 43259 51877 n/a Sizing Location............ CHICO EXP STA Winter Outside Design...... 22 F Winter Inside Design....... 70 F Summer Outside Design...... 100 F CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -FORM CF -1R I User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION ------------------------------------------------------------------------=------ Summer Inside Design....... 75 F Summer Range ............... 37 F WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value ---------------- -------- ------------------- ------ -------- ---------------- DHW - Existing 1 Instantaneous Gases Standard 1 n/a n/a R-n/a WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light -------------------------------------------------------------------- DHW - Existing 1 Instantan 0.76 n/a n/a R- n/a 500 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** ***installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This building incorporates a non-standard Water Heating System..-' DUCT SYSTEMS ------------ Verified Verified Verified System Duct Duct Duct Surface Buried Type Location ----------- R -value ------- Leakage ------- Area -------- Ducts --------- ------------- HOUSE - Existing Furnace Attic R-6 No No No ACSplit Attic R-6 No No No HOUSE -New (Added) Furnace Attic R-6 Yes No No ACSplit Attic /� R-6,--- Yes ., No No WATER HEATING SYSTEMS Number Tank External Heater in Energy Size Insulation Tank Type Type Distribution Type System Factor (gal) R -value ---------------- -------- ------------------- ------ -------- ---------------- DHW - Existing 1 Instantaneous Gases Standard 1 n/a n/a R-n/a WATER HEATING SYSTEMS DETAIL Standby Internal Tank Recovery Rated Loss Insulation Pilot System Efficiency Input Fraction R -value Light -------------------------------------------------------------------- DHW - Existing 1 Instantan 0.76 n/a n/a R- n/a 500 SPECIAL FEATURES AND MODELING ASSUMPTIONS ----------------------------------------- *** Items in this section should be documented on the plans, *** ***installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. This building incorporates a non-standard Water Heating System..-' CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 cc==cm==m=mamac=acaaaaaacaaaama======ecaaaaaca=cacaa==c=c=aaccaaaaaaaaaaac----- MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -FORM CF -IR User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION ------------------------------------------------------------------------------- HERS REQUIRED VERIFICATION *** Items in this section require field testing and/or *** *** verification by a certified home energy rater under *** *** the supervision of a CEC-approved HERS provider using *** *** CEC approved testing and/or verification methods and *** *** must be reported on the CF -4R installation certificate. *** This building incorporates HERS verified EER. This building incorporates HERS verified Duct Leakage. Target leakage is calculated and documented on the CF -4R. If the measured CFM is above the target, then corrective action must be taken to reduce the duct leakage and then must be retested. Alternatively, the compliance calculations could be redone without duct testing. If ducts are not installed, then HERS verification is not necessary. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall, design responsibility. DESIGNER or OWNER DOCUMENTATION AUTHOR Name.... GREG & DIANE Name.... BOB METZGER O.D.S. Company. WHEELER Company. Bob Metzger O.D.S. Address. 2534 DAYTON RD. Address. 2231 St. George Lane, CHICO, CA. 95928 Chico, CA 95926 Phone... 530-342-5040 Phone... 530-865-9688 License. N/A Signed.. a6 e O Signed.. ( at ) ENFORCEMENT AGENCY Name.... Title . . Agency.. Phone... Signed.. (date) Ste 70 a HVAC SIZING HVAC Page 1 ------- -------- -------------- Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 Project Address........ 2534 DAYTON RD. ******* --------------------- CHICO, CA. 95928 *v7.10* I I Documentation Author... BOB METZGER O.D.S. ******* I Building Permit # I Bob Metzger O.D.S. I I 2231 St. George Lane, Ste 70 { Plan Check / Date I Chico, CA 95926 I I 530-865-9688 ( Field Check/ Date 1 Climate Zone.. .. 11 - --------------------- Compliance Method...... MICROPAS7 v7.10 for 2005 Standards by Enercomp, Inc. I MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -HVAC SIZING I' 1 User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION 1 ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 2262 sf Volume ..................... 19097 cf Front Orientation.......... Front Facing 0 deg (N) Sizing Location............ CHICO EXP STA Latitude ................... 39.7 degrees Winter Outside Design...... 22 F Winter Inside Design....... 70 F Summer Outside Design...... 100 F Summer Inside Design........ 75 F Summer Range ............... 37 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.19 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btu/hr) ----------- (Btu/hr) --------- --------------------------------- Opaque Conduction and Solar...... 30921 12631 Glazing Conduction and Solar..... 17558 16189 Infiltration ..................... 10427 3324 Internal Gain .................... n/a 2520 Ducts ............................ 13346 8596 Sensible Load .................... 72253 Latent Load ...................... n/a Minimum Total Load 72253 43259 8617 51877 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 2 Project Title.......... WHEELER ADDITION Date..04/16/08 13:51:03 MICROPAS7 v7.10 File -WHEELER Wth-CTZ11S05 Program -HVAC SIZING I j User#-MP1722 User -Bob Metzger O.D.S. Run -WHEELER ADDITION ------------------------------------------------------------------------------- HEATING AND COOLING LOAD SUMMARY.BY ZONE ---------------------------------------- ZONE 'HOUSE' Floor Area ....................... 2001 sf Volume ........................... 17009 cf Heating Cooling Description (Btu/hr) (Btu/hr) Opaque Conduction and Solar...... 27812 10863 Glazing Conduction and Solar..... 15140 11264 Infiltration ..................... 9334 2976 Internal Gain .................... n/a 302 Ducts ............................ 122966991 Sensible Load .................... 64583 32397 Latent Load ...................... n/a 6453 Minimum Zone Load 64583 38850 ZONE 'HOUSE/N' Floor Area ....................... 261 sf Volume ........................... 2088 cf Heating Cooling Description (Btu/hr) ----------- (Btu/hr) ----------- --------------------------------- Opaque Conduction and Solar...... 3109 1768 Glazing Conduction and Solar..... 2418 4924 Infiltration ..................... 1093 349 Internal Gain.................. n/a 2218 Ducts ............................ 1050 1605 Sensible Load .................... 7670 10863 Latent Load ...................... n/a2164 ----------- ----------- Minimum Zone Load 7670 13027 MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Pagel asaaasass=semmasaar,-aaaaaaaa�caaaaeescss�=sz:ea,ce,_=.=a= .aaaaaaa=======casae===eve=a=====. Project Title.......... Project Address.; ......******* --------------------- _ *v7.10* I I Documentation Author... BOB METZGER O.D.S. ******* I Building Permit # I Bob Metzger O.D.S. J 1 2231 St. George Lane, Ste 70 ( Plan Check / Date 1 Chi.c.o,-_,CA 95926 I I I Field Check/ Date Climate Zone. ..... 11 --------------------- Compliance Method....,. MICROPAS7 77.10 for 2005 Standards by Enercomp, Inc. f MICROPAS7 v7.10 Wth-CTZ11S05 Program- Fo.,,M,MF-1R J User#-MP1722 User -Bob Metzger O.D.S. ------------------------------------------------------------------------------- 1 Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on thi,s checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a.): Minimum R-19 insulation in wood framed ceiling or in f� equivalent U -factor metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R -Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor 150(e): Installation of Fireplaces, Decorative Gas Appliances 1VT and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control r+ 2. .No continuous burning gas pilot lights allowed ct 150(f): Air retgrding wrap installed to comply with Sec. 151 meets requiiA, ents specified in ACM Residential Manual 150(g): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation' material without facings no greater than 0.3%, water vapor permeance'rate no greater than 2.0 perm/inch t' N 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF -6R form 116-17: FeAestration;Products, Exterior Doors and Infiltration/ Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage ci 2. Fenestration products (except field -fabricated) have label with certified U -factor, certified Solar Heat Gain _ Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weathers tripped; all joints - and penetrations caulked and sealed SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with"ASHRAE, SMACNA or ACCA 150(1): Setback thermostat on all applicable heating and/or��9 cooling systems --- 1 150(j): Water system pipe and tank insulation and cooling ____ systems Line insulation 1. Storage gas water heaters rated with an Energy Factor Tess than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R -value 3. The following piping is insulated according to Table 150-A/B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water `q pipes shall be insulated to Table 150B �d 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to `q Table 1.50-B and Equation 150-A Jac' 4. Steam hydropic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that due to sunlight, moisture, equipment maintenance and wind 6. Insulation for chilled water piping and refrigerant suction piping includes a -vapor retardant or is enclosed entirely in conditioned space . 7. Solar water -heating systems/collectors are certified by the ` Solar Rating and Certification Corporation *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5, supply -air and return -air ducts .and plenums are, insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL. 181, • UL-`�:��1A; `or UIQ"�81�._or."aero`soT"sealant"""��'ia�"' mee s die"'"""_-.__."_'."....'_..'...�.`-'M°'�.._..----.�...—,.�._-_._:_�.,_.,._.__..__�... requirements of UL 723. If mastic or tape is used to seal Openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used 2. Building cavities, support. platforms for air handlers, and plenums defined or constructed with materials other.than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support- platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause,f,-� reductions in the cross-sectional area of the ducts 3..Joints and seams of duct systems and their components shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually ��j� operated dampers 6 y 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant. and provides. shielding from solar radiation that can cause degradation of the materialfC? 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no ,Q electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and 'heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional.inlets and a circulation pump time switch 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) .118(i): Cool Roof material meets specified criteria | ES HTING MEASURES ------- oa- En- � sign- force u/a er meot and have an output frequency no less than .20 kHz 150 M 1: HIGH EFFICACY LUMINAIRES OTHER THAN. OUTDOOR HID: contain only high ef f icacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26). Ballast for lamps 13 watts. -or greater are electronic and have an output frequency no less than .20 kHz 15.0 W 1: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain _-oTr1,y--high _-----^ - ad6s -as outli-ined--iTr-Table 150-C, luminaire has factory installed HID ballast 150(k)3: Permanently installed luminaires in kitchens shall ---' ---' high'---- be high' efficacy lom1oaizea, op to 50 percent of the wattage, as determined in Seo. 130 (c)', of permanently installed luminaires in kitchens may be in luminaires that are not high efficacy luminaires, provided that these luminaires are controlled � by switches separate from those controlling the high efficacy luminaires tx 150(k)3, Permanently installed luminaires in bathrooms, ---- ---- --�' garages, laundry romma^ utility rooms shall be high . efficacy luminaires OR are ooutrollod.by an occupant ' l 1bi . ""=s not tvon"// automatically or have an *lwuxu on option 150(k)4: Permanently installed luminaires located other than in -kitchens, rooms shall be high efficacy luminaires. (except closets less OR are onut . with Section 119(d) that does not. turn on automatically ' or have an always on option 150(k)5;Lomivaireo that are recessed into insulated ceilings ---' ---- _--- aro approved for oazu clearance insulation cover (To) and are certified air tight to ASTM E283 and labeled as air tight (AT) to less than '2.0 CFM at 75 Pascals 150<k)6; Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) On are controlled by occupant sensors with integral photo control certified to comply ' with Section 119(d) �-_--- �| -___ I50(k)7; Lighting for parking lots for 8 or more vehicles shall , have lightingthat complies with oec' 130, 132, and 147. Lighting parking garages for 8 or more vehicles shall � have lighting that complies with aeo' 130, I31, and 146 I50(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four ' or more dwelling units shall be high efficacy luminaires OR | are controlled by an occupant oeuonr(o) certified to comply with Section 119(d) rol =0a IF APPLIES GENERAL NOTES SHEET -E 1. ALL PENETRATIONS THRU THE BUILDING ENVELOPE (CLG. WALLS AND FLOORS)lb 6E CAULKED, SEALED OR WEATHER STRIPPED. .SHIM SPACES AROUND EXTERIOR. DOORS, OF THE BUILDING ENVELOPE TO BE INSULATED. 2. ALL EXTERIOR PANELS EDGES TO BE CAULKED. 3. ANY ACCESSESS TO ATTIC SPACE OR CRAWL SPACE FROM CONDITIONED SPACE TO BE FULLY WEATHER STRIPPED. 4. EXHAUST FANS TO HAVE BACKDRAFT DAMPERS. 5. FIRE PLACES TO HAVE. a) O.S. COMBUSTABLE AIR TO F.P. BOX W/ MIN. DUCT CROSS-SECTIONAL AREA OF 6 SSD . INCHES b) DAMPERS TO 'DUCT ___ ACCESSABLE FROM INSIDE F.P. AREA c) FLUE .DAMPER.:.TIGHT-FITTING 8 READILY ACCESSABLE d) TIGHT -FITTING F.P. DOORS OR HEAT CIRCULATING DEVICE. 6. A/C DUCTS TO BE INSTALLED PER lA Ck1 U.M.C. & INSULATED (1" INSUL. GAS EQUIP.) & (2" INSUL.-HEATPUMP'EQUIP.) 15# DENSITY TYP. 7.' MAIN LIGHTING SOURCE IN ALL BATHS & KITCHEN TO BE FLOURESCENT OF 40 LUMENS/WATTS OR GRATER. 8. FAUCETS & SHOWER HEADS TO BE WATER SAVING TYPE 8 CERTIFIED BY C.E.C. 9. W.H. TO HAVE. a) V-6" HIGHT PLATFORM. b) . VENT T HRU ROOF.. 0 ADEQUATED CONBUSTABLE AIR VENTING - Z R-4 INSULATION 5'-0" TO & FROM UNCOND. SPACE. e) R-12 INSULATION WRAPPING.Lr-Jw1.l ouj ap. o� f) R -d- INSULATION ON CIRCULATING SYSTEM. S) CERTIFIED BY C.E.C. 10. GAS COOKING APPLIANCES NOT TO HAVE CONTINUOUS BURNING PILOT LIGHT. 11 A/C UNIT TO HAVE a) SIZED & CERTIFIED BY C.E.C. b) SET -BACK THERMOSTATS. f 12. INSULATION INSTALLER TO BE CERTIFIED BY STATE & LOOSE FILL INSULAT- ION TO HAVE MANUFRS. LABLED R -VALUE 13 BUILDER TO SUPPLY -TO OWNER ALL INFO. PERTAINING TO THE OPERATION OR TREATMENT OF ALL APPLIANCES & DEVICES RELATED TO ENERGY OR WATER USE. 14. ALL WOOS. @ CONDITIONED SPACED DUAL -PANE. DOORS 8 WDOS. TO BE FUL- LY WEATHER STRIPPED. 15. CAULK BETWEEN BOTTOM PLATE AND CONC. FLOOR. 16. PROVIDE INSULATION BAFFLES @ EAVE BLOCK VENTS. 17. USE ELECT. OUTLET GASKETS @ O.S. WALLS. 18 WATER HEATER .TO HAVE P -T VALVE WITH DISCHARGE TO OUT SIDE. 19. REF. FRZRS. FLUR. LAMP BALLAST TO BE CERTIFIED BY C.E.C. CON TRACT- OR -OWNER TO SUPPLY -MAKE AND MODEL. i I f ing; -- er:ature 702 ,c- . ��---1=— ✓0\z(�r ELECTRICAL LEGEND -220V PLUG GFI - GROUND FAULT INTERFERENCE ( - DUPLEX PLUG (FAN) = FAN ONLY -- STD. LIGHT (L I& F) = LIGHT & RECESSED LIGHT ... CLG. FAN FLUR. - FLOURESCENCE LIGHT - EXHAUST FAN STD. SWITCH I- SWITCH w/ DIMMER J --i (- DOOR BELL CHIMES r— -1- - DOOR BELLCHIMES r rIO'J - HARDWIRE. SMOKE DETECTOR w/ BATTERY BACK-UP r 5 N APPROVAL r 77 TITLE -24 ELECTRICAL NOTES 1. KITCHEN: HIGH-EFFICANCY OR UP TO 50% OF THE TOTAL WATTAGE SHALL BE LOW-EFFICANCY. ALL HIGH -EFFICACY & LOW -EFFICACY LIGHTING MUST BE CONTROLLED SEPERATELY. AND IN ADDITION 50% OF KITCHEN LIGHT MUST BE FLUR. LIGHTING. ALSO 2-20 AMP. APPLIANCES CURCUITS TO KITCHEN MUST BE PROVIDED. 2. BATHROOM: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. A 1 -MIN. 20 AMP. CURCUIT & PLUG TO EACH BATHROOM MUST BE PROVIDED. 3. GARAGE: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. 3a. GFI OUTLETS TO BE ON A SEPERATE CIRCUITS 4. LAUNDRY RM: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. A 1 -MIN. 20 -AMP CURCUIT & PLUG MUST BE PROVIDED TO THE LAUNDRY RM. AREA PER. 210.11.C.2 (SERVES NO OTHER). S. UTILITY RM: HIGH-EFFICANCY OR MANUAL -ON OCCUPANCY SENSOR. ALL OTHER ROOMS (E.G., LIVING RM., DINING RM., BEDROOMS, HALLWAYS) EXCEPT CLOSETS LESS THAN 70 SQ. FT: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR OR DIMMER. ALL LIGHTS AND RECEPTACLES, OTHER THEN ADD. WALL RECEPTACLES, SHALL NOTBE ON THIS CIRCUIT UNLESS SEPERATE 20 AMP. GFI BRANCH CIRCUIT IS PROVIDED @ EACH RM. PROVIDE ARC. FAULT CIR. BREAKERS IN EACH AND ALL BEIDROOMS. (INCLUDING LIGHTS & SMOKE DETECTORS) 6. OUTQOIIB_.L 7GHTING ATTACHED TO BLDG: HIGH -EFFICACY OR CONTROLLED BY MOTION SENSOR WITH PHOTOCONTROL. ALL EXT. ELECTRICAL FIXTURES, INCLUDING 0. S. LIGHTS, FANS, ECT, SHALL BE SUITABLE FOR DAMP/WET CONDITIONS AND WHILE IN USE. %. CELLING FANS BOXES MUST BE -LISTED PER. CEC 422-118. 8. RECESSED LIGHTS MUST BE IC & AC RATED. 9. PLUGS ON OPPOSITE SIDES OF THE GAR -HOUSE FIRE WALL TO BE SEPERATEb BY A CONT. VERT. 2X STUD M 6" MIN. APART, 10. SMOKE DETECTORS TO BE HARD WIRED w/ BATTERY BACKUP & AUDIBLE IN ALL BEDROOMS. 11. GFI CIRCUITS TO BE PROVIDED AT: KIT. COUNTER RCPT. & BATH COUNTER RCPT. & GAR. RCPT. & 0. S. RCPT. oR tir 4 f oST t ..�/$d a0 O G, 9. 41 N 17ow 01x OR 14C LA tbd e FC- F. rl0'("tr , co Ac' ' Ja TO ,�'b tiP on'SR er• Pal'oT BE - fq? it bTM. ��26ro(LY'] s u Y nqALIML � +r . "1 d i 0 hr„ MI pt+►.. A ��---1=— ✓0\z(�r ELECTRICAL LEGEND -220V PLUG GFI - GROUND FAULT INTERFERENCE ( - DUPLEX PLUG (FAN) = FAN ONLY -- STD. LIGHT (L I& F) = LIGHT & RECESSED LIGHT ... CLG. FAN FLUR. - FLOURESCENCE LIGHT - EXHAUST FAN STD. SWITCH I- SWITCH w/ DIMMER J --i (- DOOR BELL CHIMES r— -1- - DOOR BELLCHIMES r rIO'J - HARDWIRE. SMOKE DETECTOR w/ BATTERY BACK-UP r 5 N APPROVAL r 77 TITLE -24 ELECTRICAL NOTES 1. KITCHEN: HIGH-EFFICANCY OR UP TO 50% OF THE TOTAL WATTAGE SHALL BE LOW-EFFICANCY. ALL HIGH -EFFICACY & LOW -EFFICACY LIGHTING MUST BE CONTROLLED SEPERATELY. AND IN ADDITION 50% OF KITCHEN LIGHT MUST BE FLUR. LIGHTING. ALSO 2-20 AMP. APPLIANCES CURCUITS TO KITCHEN MUST BE PROVIDED. 2. BATHROOM: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. A 1 -MIN. 20 AMP. CURCUIT & PLUG TO EACH BATHROOM MUST BE PROVIDED. 3. GARAGE: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. 3a. GFI OUTLETS TO BE ON A SEPERATE CIRCUITS 4. LAUNDRY RM: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR. A 1 -MIN. 20 -AMP CURCUIT & PLUG MUST BE PROVIDED TO THE LAUNDRY RM. AREA PER. 210.11.C.2 (SERVES NO OTHER). S. UTILITY RM: HIGH-EFFICANCY OR MANUAL -ON OCCUPANCY SENSOR. ALL OTHER ROOMS (E.G., LIVING RM., DINING RM., BEDROOMS, HALLWAYS) EXCEPT CLOSETS LESS THAN 70 SQ. FT: HIGH -EFFICACY OR MANUAL -ON OCCUPANCY SENSOR OR DIMMER. ALL LIGHTS AND RECEPTACLES, OTHER THEN ADD. WALL RECEPTACLES, SHALL NOTBE ON THIS CIRCUIT UNLESS SEPERATE 20 AMP. GFI BRANCH CIRCUIT IS PROVIDED @ EACH RM. PROVIDE ARC. FAULT CIR. BREAKERS IN EACH AND ALL BEIDROOMS. (INCLUDING LIGHTS & SMOKE DETECTORS) 6. OUTQOIIB_.L 7GHTING ATTACHED TO BLDG: HIGH -EFFICACY OR CONTROLLED BY MOTION SENSOR WITH PHOTOCONTROL. ALL EXT. ELECTRICAL FIXTURES, INCLUDING 0. S. LIGHTS, FANS, ECT, SHALL BE SUITABLE FOR DAMP/WET CONDITIONS AND WHILE IN USE. %. CELLING FANS BOXES MUST BE -LISTED PER. CEC 422-118. 8. RECESSED LIGHTS MUST BE IC & AC RATED. 9. PLUGS ON OPPOSITE SIDES OF THE GAR -HOUSE FIRE WALL TO BE SEPERATEb BY A CONT. VERT. 2X STUD M 6" MIN. APART, 10. SMOKE DETECTORS TO BE HARD WIRED w/ BATTERY BACKUP & AUDIBLE IN ALL BEDROOMS. 11. GFI CIRCUITS TO BE PROVIDED AT: KIT. COUNTER RCPT. & BATH COUNTER RCPT. & GAR. RCPT. & 0. S. RCPT. oR tir 4 f oST t ..�/$d a0 O G, 9. 41 N 17ow 01x OR 14C LA tbd e FC- F. rl0'("tr , co Ac' ' Ja TO ,�'b tiP on'SR er• Pal'oT BE - fq? it bTM. ��26ro(LY'] s u �G.�Nt r-� u. LG, A` w� ctLl►1 ED nqALIML int . "1 6LA6 Ft40(L Go p.51M. 0 hr„ MI pt+►.. W) 1 0-,%U I ID 00 )-J NDDITiON k I IL PTL o fl� ff T-1 ff n it tr room- D4k-T-tot4 .. LEGEND (N) WALL (E) WALL REMOVED T�-Q- = (E) WALL (E) = EXISTING (N) = NEW OR ADDED REF. = REFERENCE TO (E) & VERIFY ALL INFO. IN FIELD APROXIMATE • VS4 - --- ------- r f � I r-- -:I �CDIf l A(,'V) /IM 4vL% I n 10 VERIFY ALL DEMINISIONS, NOTES, & VIEWS OF FIELD GENERAL NOTES THIS DRAWING BY BOB METZGER-O.D.S. HAS BEEN PROVIDED FOR THE OWNER ACCORDING TO THE CALIFORNIA BUILDING & PROFESSIONAL CODE, & CONTRACT BETWEEN BOB METZGER AND THE OWNER. FOR ANY QUESTIONS PLEASE CALL BOB METZGER OR OWNER. BOB METZGER-O.D.S. IS NOT AN ARCHITECT, OR IN ANY WAY REPRRESENTS ITSELF AS AN ARCHITECT OR ENGINEER. ALL ENGINEERING, IF NEEDED, FOR THIS PROJECT WILL BE DERTERMINED BY THE LOCAL BUILDING DEPARTMENT. THE ENTIRE PROJECT IS SUBJECT TO THE APPROVAL AND INSPECTION OF THE LOCAL BLDG. DEPT. BOB METZGER-O.D.S. IS NOT RESPONSIBLE FOR ANYONE'S INTERPRETATION OF THIS PLAN. STANDARD NOTES 1. VERIFY ALL DEMINSIONS, NOTES, & VIEWS OF FIELD. 2. SEE ATTACHED SHEETS FOR T-24 ENERGY CALCS. (KEEP w/ PLANS). 3. LUMBER; No. 2 D.F. LARCH TYP. U.O.N. (or BETTER). 4. ALL CONC. TO BE 2500 P.S.I., 28 DAYS, 5 SACK Min. S. PROVIDE DBL. TRIMMERS OVER OPENINGS. LARGER THAN 8'-0" U.O.N. 6. SOIL BEARING RESISTANCE IS BASED ON 1200 P.S.F. 7. (—) = APPROXIATE 8. A/C COND. UNIT(s) NOT TO BE WITHIN NARROW SIDEYARIDS. 9. ADDRESS #s TO BE LARGE ENOUGH TO BE CLEARLY SEEN FROM STREET. (4" HIGH MIN. CHARACTERS). 10. BOB METZGER IS NOT AN .0ARCHITECTAND WILL NOT PROVIDE ANY ENGINEERING SERVICES 11. ALL PLUMBING WALLS w/ LARGE VENTS & DRAINS=2x6 (OR LARGER. 12. PROVIDE TOTAL AREA OF PLUMBING VENT THUR. ROOF '.> MAIN SEWER LINE Per. TABLE 7-A U.P.C. (4" �= 12.56 S.F.). 13. HOSE BIBS TO HAVE BACK-FLOW DEVICES. 14. PROVIDE HAMMER DEVICE @ QUICK ACTING VALVES Per. U.M.C. 15. FOR ELEC. NOTES & INFO. SEE SEPERATE LIST OF T-24 (NOTES. d G IL UTTE COUNTY UrLi�'Ai�a j NISI �\ APPROVED _Ilk lki f d G IL UTTE COUNTY UrLi�'Ai�a j NISI �\ APPROVED _Ilk lki