Loading...
HomeMy WebLinkAbout039-460-032"COMPLAIN: TO INSPECTOR l 39-4625'2 2408-91B' CLAWSON, Glenn , 9343 Holland Ave, Durham cont: Butte Roofing ) (reroof/sf) I / f - B08-2087 039-460-032 MISCELLANEOUS Electric Panel NEW ELECTRIC PANEL SERVICE UP 9343 HOLLAND AVE DAVIS MICHAEL J'& DE, . ow �a S�aa a �; - l- F�i BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR): (530) 538-4365 OFFICE: (530) 538-7541 FAX#: (530) 538-2140 ONLINE PERMIT/RENEWAL PAYMENTS: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 9343 HOLLAND AVE Owner: Permit No: B08-2087 APN: 039-460-032 DAVIS MICHAEL J & DE, Issued Date: 10/14/2008 By TMP Permit type: MISCELLANEOUS 9343 HOLLAND AVE Subtype: Electric Panel DURHAM, CA 95938 Expiration Date: 10/14/2009 Description: NEW ELECTRIC PANEL SERVICE (530) 518-7500 Occupancy: Zoning: R1 Contractor Applicant: Square Footage: BARKER ELECTRIC BARKER ELECTRIC Building Garage Remdl/Addn 2935 RODEO AVENUE 2935 RODEO AVENUE CHICO, CA 95973 CHICO, CA 95973 Other Porch/Patio Total (530) 342-4806 (530) 342-4806 FEE INFORMATION DBE Single Phase Service-Resid $59.00 Total Charged: $59.00 Fees Paid: $59.00 Balance Due: $0.00 Receipt No: B8832 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License BARKER ELECTRIC 626363 / C10 / 08/31/2009 Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Sed' vision f th Business and Professions Code, and my license pursuant to the provisions of the Contractors License Law [Chapter 9 (commencing with Section 7000) is i7ndeffect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects X 10/14/2008 the applicant to a civil penalty of not more than five hundred dollars [$500); Please check one of the following: Signatu Date M ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of the property, who builds or improves thereon, and who does ORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: the work himself or herself or through his or her own employees, provided that such improvements ❑I HAVE AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by ❑❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Professions Code: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. The Contractors License Law cows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors License Law.). Cartier: Policy Number. Exp. Date: (This section need not a competed if the permit is or one a hundred dollars ($10o) or ess. ❑ 1 AM EXEMPT under Section B. 8 P.C. for this reason: �I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, and agree that if I should become subject to the workers'X 10/14/2008 compensation provisions of Section 3700 of Labor ode, I shall forthwith comply with those Owners Signature Date provisions. X 10/14/2008 I hereby certify that I have read this application and state that the above information is cored. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building Sig tore Date WARNING: FAILURE T SECUCWORKERS-COMP ENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EM TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE injury, including death, and property damage caused by, arising out of, or in any way connected with HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. County to enter the above mentioned property for inspection purposes. I hereby certify that I am the property owner or amauthorizedt property ersbehalf. 10/14/2008 CONSTRUCTION LENDING AGENCY 1 HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Narfle Of Permittee [SIGN] Print ate the performance of the work for which this permit is issued. (3097 civ. code) Owner Contractor OR;Agent for Owner DAgent for Contractor FILE COPY Lenders Address City State Zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION" OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds PLEASE PRINT CLEARLY PERMIT NO. �( G .0 BIN # "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. APPLICANT INFORMATION OWNER INFORMATION Last Nam Name FI me Mailing Ad Address City�J State S Zi Phon Q O Fax E -mad Q APPLICANT INFORMATION CONTRACTOR Name Name -� C Zip Address Fax State City Phone S& t Fax Z' Plog Q Fax _ 3 -77 E-mail Lic. j Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name City Address Zip City Fax State Zip Phone Fax E-mail State License Number APPLICANT INFORMATION Name Address City State Zip Phone Fax E-mail PROJECT LOCATION AP# < QJ Q 2 Property Address 3/ C/ City bq. c/ 3 WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than licensed contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: Zoning Flood Zone SRA I Yes I No Occ. Type Const. BUTTE COUNTY DEVELOPMENT SERVICES COMPLAINT R Date: �Ilds-- AP#: 0 3 9 -- e/k) - 6 3 Z Owner: �� C�� e l 5 l� General Plan: Owner: 3� 3 GC Com, Address: Ci 9S-939 City Zip: Cofnplaint/Violation Location: TYPE: { } Building { } Health COMPLAINT: Zoning: Z 1D k Supervisorial District #: ;1/ i3 �f3 � � Gr' ,, Zlze { } Planning { } Housing Permit History on File { } None { } See Attached Tenant: INSPECTOR'S REPORT Address: 11cc. Zq- L0 Complaint Taken By: eW7 0,� te- / oew Caution: { } Yes Why: Description of Violation: C111 C)c� I�l�- Approx. Size of Bldg/MH: Approx. Age of Bldg/MH: { } Occupied Has Electricity { } Yes { } No Has Gas/Propane { } Yes { } No { } Vacant Has Sanitation { } Yes { } No Obvious Sewage Problems { } Yes { } No Under Construction { } Yes { ) No Built by/for { } Present Owner { } Previous Owner Hazards: { } No { } Yes (explain) Person Contacted: Describe Action Taken: INSPECT ST ATTACK A COPY OF THE CORRECTJO� NOTICE!! Inspect ��' Date: C.//7 UJ' ACTION RECOMMENDED { Information Only, File { } Hold for Days Complaint Unfounded { } Other { Resolved per Inspector's Report { } Send Letter of Compliance T--- --- ----, -3__-. - _1-J. -1.... --. 1—+;— ^- 0— 1-.nn1r -f 0— cb..+ BUTTE COUNTY DEVELOPMENT SERVICES COMPLAINT FORM This information is not available to the public! ! ! ! ! ! ! DO NOT COPY FOR THE PUBLIC OR THE FIELD INSPECTOR!! The following information is required for Housing Complaints and the Complainant MUST BE the person living at the complaint address! Complainant: Address: Phone Number: The above information is not available to the public!!!.". '..I (2) BUTTE COUNTY DEVELOPMENT SERVICES COMPLAINT FORM Date: I�® AP#: 0 3 9— el6o -Z: 6 7 -,2 - Owner: 2Owner: ,e l 5 G ,�Gw7a General Plan: Z /� Owner: 3L13 ��LcC� Lam. Zoning: Address: // Gtr `� chi Ci C-�% 3 S Supervisorial District #: City Zip: // Complaint/Violation Location: Gl a y,� f �2����� Gam,, Zz, za- ,-t TYPE: { } Building: { )Health { } Planning { } Housing Complaint Taken By:S COMPLAINT: Permit History on File { } None { } See Attached Tenant: Description of Violation: INSPECTOR'S REPORT Address: At� 'e- / Z"W Caution: { } Yes Why: Approx. Size of Bldg/MH: Approx. Age of Bldg/MH: { } Occupied Has Electricity { } Yes { } No Has Gas/Propane { } Yes { } No { } Vacant Has Sanitation { } Yes { } No Obvious Sewage Problems { } Yes { } No Under Construction { } Yes { } No Built by/for { } Present Owner { } Previous Owner Hazards: { } No { } Yes (explain) Person Contacted: Describe Action Taken: INSPECTOR MUST ATTACH A COPY OF THE CORRECTION NOTICE!! Inspector: Date: ACTION RECOMMENDED { } Information Only, File { . ) Hold for Days { )Complaint Unfounded { } Other { } Resolved per Inspector's Report { } Send better of Compliance r- -- - _c_- --- - -2__-. - _1..c -1-- -44.1. -11 1 -:TA.-- 1-+-- -- +1- i.nnlr -f +b;o drool' ^l:�Y•"Iifi`-'�`. Kl'�"tf",�'-'.h`�(;:ie:'.e-�^s:s`%'rl'n:'i;.�er :T'!!.U«s7�`�ic.}�r•: x;,l1;I;l,:.,e,:. ice.-I'' .,. ,�,;v.-� .'�T^r;r-. +A�r.r. a-•- ,�. . - = 9-46-32 2408-91B CLAWSON, Glenn 9343 Holland Ave, Durham cont: Butte Roofing (reroof/sf) Lt kutn" �I COUNTY OF BUTTE -, DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7"County Center Drive Orovllle,,Callfornla 95965 - Telephone: 916/538-7541 APPLICATIA AND. PERMIT I if ASSESSOR PARCEL NUMBER l �x.�� ! ! ZONING /C BUILDING PERMIT OWNER TELEPHONE SQ. FT. 4'OCC. I BUILDING VALUATION OWN /// EEWSAILIN DDR S4 l��� / / 8vk�z CO TRACTOR'S N TELEPHONE CO C OR' AIL, G D R SS J5 V -Fireplace CONSTRUCTION NDER UNKNOWN Total Valuation $ Filing Fee $ ;0,00 LENDER'S MAILING ADORES Per^q(t Fce $ , ARCHITECT OR L,4 ;INEIEP. v ESE o• LICNN Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S M \I LING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 3 ar ¢ Each ,Trap 2.00 Solar or heat pump water heater 20.00 LOT NO.SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE i SF Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 10.00ea TYPE OF WORK 1 New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other Describe work: ( Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business(POWER and Professions Code and my license is In full force and effect. q/ �2 0 0 "Classification. C-- / License No. -C- : ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ontract- ❑ I, as the owner, am exclusively contracting with licensed contract-ors. ors.(Sec. 7044) / ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.& New DNNSTFL AMULTI-OUTLET ) , hdsgft NON.RESID BRANCH CIRCUITS) 2.50 ea APPARATUS e) (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES .220050e 00(930 Ex. Occup. OUTLETS FIXED P(RESID )REA.) 2.00 Temporary service 10.00 Mobile Home Facilities 1.5.00 Misc. Wiring i 15.00 4 Permit Fee $ .Contractor _ _ WORKMEN'S'COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. rVi I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate _ of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation penult Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agai/ns s ii/d)county i�ncnseq a he.granting of this permit. (� X Date1 / Signature of Applicant - Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and de lition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $ HALcuA PARK SCHL PLD cDF PAR PD i HD. (SSU This permit is hereby issued under the applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated above for which fees have been aid. I f 'I 1 p IRE, T OF PUBLI, WORKS A n By A� r Da / PERMIT EXPIRES Date % 9 Receipt No. 77 ;73 � 35�f- WHITE-D.P.W., YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, Californ'it 95965 - Telephone: 916/538-7541 APPLICATION JD PERMIT PERMIT NO. ASSESSOR PARCEL NUMBER _ ZONING 332—G BUILDING PERMIT 164 i OWNER.—/.TELEPHONE SO. FT. DCC. BUILDING VALUATION TIM,AI LIN DR S O TR CTOR' N TELEPHONE - n3 C C OR' AI LSI D SS Fireplace CONSTRUCTION VENDER UNKNCWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRE —OR Penni: Fee $ x,00 ARCHITECT L.� ;liner LICENSE No. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEEF'S M (LING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 3 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO.SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF Duplex❑ Mobilehome❑ Other SPECI FV Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 10.00 ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation[] Other ( Describe work: +(_ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100 AMP OR1 OR LESS10.00 Main Service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): �(f I am licensed u:.nder provisions of Chapt. 9, Div. 3 of the BU$Ines$ /\ and Professions �Code and my license is In full force and effect. License No.ST� 76 0 D Classification. C��� ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do The work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. I DWELLING OCCUP.& OR ADONS. % ACC. BLOGS. , �2�SQ ft NEW CONSTR MULTI—OUTLET NON.RESID BRANCH CIRC ITS 2.50 ea POWER APPARATUS 61 SINGLE OUTLET CIR. / EX. Occup(OUTLETS OR FIXTURES0 5 AL0 AL@ 3 FIXED APLNS. \ Ex. OCCUp. OUTLETS (RESID )REAJ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Se f -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If af-er making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling g Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue agains `ai County in c se rice ranting of this permit. X �� �g� Date / ... —�- Signature of Applicant — Owner ❑ Contractor ❑ Agent IN An OSHA permit is required for excavations over 5'0" deep and de lition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $ p— 31-1 .1 HAi. CUA- PARK SCHL FLD coF PAR Po 1 Ho. Issu This permit is hereby issued under the applicable provi- sions of the Butte County -Code and/or resolutions to do work indi d above for which fees have been paid. IRE OF PU L WORKS By Da14 ? / PERMIT EXPIRES Date Receipt No. 05c573� 35- WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR. GOLDENROD -APPLICANT BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR): (530) 538-4365 OFFICE: (530) 538-7541 FAX#: (530) 538-2140 ONLINE PERMIT/RENEWAL PAYMENTS: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 9343 HOLLAND AVE Owner: Permit NO: B08-2405 APN: 039-460-032 DAVIS MICHAEL J & DE, Issued Date: 12/5/2008 By GLB Permit type: MISCELLANEOUS 9343 HOLLAND AVE Subtype: Phtovtaic Sys Grnd DURHAM, CA 95938 Expiration Date: 12/5/2009 Description: ROOF MOUNT SOLAR SYSTEM (530) 894-8068 Occupancy: Zoning: R1 _ Contractor Applicant: Square Footage: ALTERNATIVE ENERGY SYSTEMS INC ALTERNATIVE ENERGY SYS Building Garage Remdl/Addn P O BOX 9231 P O BOX 9231 CHICO, CA 959279231 CHICO, CA 959279231 (530)345-6980 (530)345-6980 Other Porch/Patio Total FEE INFORMATION DBMSC Photovoltaic System $421.93 Total Charged: $421.93 Fees Paid: $421.93 Balance Due: $0.00 Receipt No: B9283 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires ALTERNATIVE ENERGY SYSTE 853351 / C10 / 1131/2009 I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 also requires the applicant for such permit to file a signed statement that he or she is licensed (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law (Chapter 9 (commencing with Section 7000) is in full force and ect of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the X basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil of than five hundred 12/5/2008 penalty not more dollars [$500]; Please check one of the following: Contractors Signature Date ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractor's License WORKERS' COMPENSATION DECLARATION I HER BY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: Law does not apply to an owner of the property, who builds or improves thereon, and who does HAVE AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR the work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). ❑ I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by Section 3700 the Labor Code, for E]1, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Professions Code: of the performance of the work for which this permit is issued. My Workers' Compensation insurance carrier and policy number are; The Contractor's License Law dows not apply to an owner of the property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Carrier: STATE FUND Policy Number: 713-0019419 Exp. Dale:5/1/2009 Contractor's License Law.). (This section nee not a competed if the permit is or one hun re dollars ($100) or less. ❑ I AM EXEMPT under Section B. & P.C. for this reason: ❑I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, and agree that if I should become subject to the workers'X 12/5/2008 compensation provitnaa.,o4ection 3700 of the Labor Code, I shall forthwith comply with those Owners Signature Date provisions. X 12/5/2008 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and Stale laws relating to building Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, injury, includirg death, and property damage caused by, arising out of, or in any way connected with DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. County to enter the above mentioned property for inspection purposes. I hereby certify that I am the prope -owner authorized to act on the prop ertyo efsbehalf. CONSTRUCTION LENDING AGENCY 12/5/2008 1 HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name f Permittee [SIGN] Print Date the performance of the work for which this permit is issued. (3097 civ. code) Owner n Contractor OR Agent for Owner ❑Agent for Contractor V FILE COPY Lenders Address City State zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE_ WILL BE REQUIRED AT TIME OF APPLICATION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" OWNER INFORMATION Last Name OCLU1< First Name I 1 re Mailing Address 713 4o' J City tate G A Zip s Phone ��- y _ 6'3 ax EF E-mail CONTRACTOR Name / Address City i cep State Zip'% Z Phone-,.,/ �D Fax E-mail Lic. #9s .33 Clas C✓ (D APPLICANT SIGNATURE Ir , X PERMIT NO. BIN # PROJECT LOCATION AP# © , Property Address 17313 LJoa � d � City L C- /A rt WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must he shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK.- Sq ORK.Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office onl ARCHITECT/ENGINEER Name Type Const. Address City State Zip Phone Fax E-mail State License Number APPLICANT SIGNATURE Ir , X PERMIT NO. BIN # PROJECT LOCATION AP# © , Property Address 17313 LJoa � d � City L C- /A rt WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must he shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK.- Sq ORK.Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office onl APPLICANT INFORMATION Name Type Const. Address City State Zip Phone Fax E-mail APPLICANT SIGNATURE Ir , X PERMIT NO. BIN # PROJECT LOCATION AP# © , Property Address 17313 LJoa � d � City L C- /A rt WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must he shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK.- Sq ORK.Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office onl Zoning Flood Zone SRA I res No Occ. Type Const. PG&E MAIN 150' METER r- -------------------- ---- ----------- ----- --------.-.--, I i i INVERTER LOCATION i I I I i 25'-� ! PROPOSED SOLAR ARRAY LOCATION FLUSH MOUNTED AND INSTALLED PER MANUFACTURES ; i 0 INSTRUCTIONS I DRIVEWAY i i (RAIL SPAN NOT TO EXCEED 4'EXISTINIG HOME ; ! OR CANTILEVER MORE THAN 16�� ) I I i I i SHED o_ i i i � I �._ _.- _._._._._ _._._.-._._._:_._._._ _._._._._._._._._._._._ _._._._ _._._ _ _ _._. ------ ------ LOCATION/SITE: _._ LOCATION/SITE: DESIGNED AND INSTALLED BY MIKE DAVIS ALTERNATIVE ENERGY SYSTEMS INC. 9343 HOLLAND AVE PO BOX 9231, CHICO, CA 95927 DURHAM, CA 95938 LANCE MCCLUNG, C-10, 853351 PHOTOVOLTAIC SOLAR SYSTEM DRAWING SCALE .06"=1' 12-3-2008 -5F couwl BIJ 8ul. R'SSON o . C� PHOTOVOLTAIC SOLAR SYSTEM 6 (10) SPR -225-1 I (10) SPR-225- BLK-U PV BLK-U PV MODULE MODULE 10GA Note: A separate ground will be required for lightning suppression and bonded to main ground at the as near to inverter as possible. All mounting to be flashed sealed and installed in accordance with manufacturers instructions. DC array wires are to be metallic from roof penetration to the inverter All electrical wiring will be installed in accordance with the 2007 Califorina Building Code and 2005 NEC article 690. SUNPOWER SPR -4000m-240 4KWATT INVERTER with integrated DC Disconnect MAIN METER 0 CB30 CB30 LOCATION/SITE: DESIGNED AND INSTALLED BY PHOTOVOLTAIC SOLAR SYSTEM MIKE DAVIS ALTERNATIVE ENERGY SYSTEMS INC. 9343 HOLLAND AVE PO BOX 9231, CHICO, CA 95927 DRAWING SCALE .025"=1' LINE ITEM DIAGRAM DURHAM, CA 95938 LANCE MCCLUNG, C-10, 853351 12-4-2008 ARRAY DEAD LOAD CALCULATION ITEM PANEL RAIL STRUT TILT LEGS # EA 20 6.75 0 • 0 LENGTH (FT) : 17 16 WEIGHT/FT (LB) 1 1.9 WEIGHT EA (LB) 33 5 WEIGHT/ITEM (LB) 660 114.75 - 0 SUM 775 LB AREA 300 FT"2 WEIGHT/FT"2. 2.6 PSF Location: Designed & Installed by: Mike Davis ALTERNATIVE ENERGY SYSTEMS INC 9343 Holland Ave PO Box 9231 Durham, CA 95938 Chico, CA 95927 BENEFITS Highest Efficiency Panel efficiency of 18.1 % is the highest commercially available for residential applications Attractive Design Unique design combines high efficiency and an elegant, all -black appearance More Power Delivers up to 50% more power per unit area than conventional solar panels Reliable and Robust'Design Proven materials, tempered front glass, and a sturdy anodized frame allow panel to operate reliably in multiple mounting configurations SPR-225-BLK 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE The SunPower 225 Solar Panel provides a revolutionary combination of high efficiency and attractive, uniform appearance. Utilizing 72 next generation SunPower all - back contact solar cells and an all -black backsheet, the SunPower 225 elegantly delivers an unprecedented total panel conversion efficiency of 18.1 %. The panel's reduced voltage -temperature coefficient and exceptional low -light performance attributes provide far higher energy delivery per peak power than conventional panels. SunPower's High Efficiency Advantage - up to 50% More Power Comparable systems covering 25 m2 / 270 h2 Conventional r SunPower Watts / Panel 165 225 Efficiency 12.0% 18.1% kWs 3.0 4.5 CEc us e: �d 225 SOLAR PANEL EXCEPTIONAL EFFICIENCY AND APPEARANCE Electrical Data Measured al Standard Test CondiBons ISrcl: irradiance of 1000/m2, air _ moss 1.5g, and cell temperature 25° C Peak Power (+/-5%) Pmax 225 W Rated Voltage Vmp 41.0 V Rated Current Imp 5.49 A Open Circuit Voltage Voc 48.5 V Short Circuit Current Isc 5.87 A Maximum System Voltage IEC, UL 1000 V, 600 V Temperature Coefficients Power -0.38% /oC Voltage (Voc) -132.5 mV/aC Current (Isc) 3.5 mA/aC Series Fuse Rating 20A Peak Power per Unit Area 181 W/m2, 16.8 W/ft2 CEC PTC Rating 207.1 W IV Curve 7.0 t 6.0 5.0 r 1000 W/m2 A501 -C 4.0 800 W/tae3.02.0 f S00 W/m21.0 _ 1000 W 0.0 - 0 10 20 30 40 50 60 Voltage (1/) Current/voltage characteristics with dependence on irrodiance and module temperature. Tested Operating Conditions Temperature -404 C to +854 C (-40aF to +185of) Max load 50 psf (2400 Pascals) front and back Impact Resistance Hail - 25mm (1 in) at 23 m/s (52 mph) Warranty and Certifications Warranty 25 year limited power warranty 10 year limited product warranty Certifications IEC 61215, Safety tested IEC 61730 UL listed (UL 1703), Class C Fire Rating Dimensions nun rri IF 1� 1200 4.2 C16 2X04.2 6161 IGa�41 + "1 754 129.691 4 91s 2X2 �f �1I ®Ie6.61.26) (36.0521 112.69) �1 11:11 "' 04.21161 lc ­ l CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Go to www.sunpowercorp.com/panels for details About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. ® October 2007 SunPower Corporation. All rights reserved. Specificctions included in this datasheet are subject to change without notice. Document #001.42188 Rev %0 Printed on paper d e recr cla p p www.sunpowercorp.com Mechanical Data Solar Cells 72 SunPower allback contact monocrystalline Front Glass 3.2 mm (1/8 in) tempered Junction Box IP -65 rated with 3 bypass diodes Output Cables 900mm length cable / MultimContoct connectors Frame Anodized aluminum alloy type 6063 Weight 15 kg, 33 lbs IV Curve 7.0 t 6.0 5.0 r 1000 W/m2 A501 -C 4.0 800 W/tae3.02.0 f S00 W/m21.0 _ 1000 W 0.0 - 0 10 20 30 40 50 60 Voltage (1/) Current/voltage characteristics with dependence on irrodiance and module temperature. Tested Operating Conditions Temperature -404 C to +854 C (-40aF to +185of) Max load 50 psf (2400 Pascals) front and back Impact Resistance Hail - 25mm (1 in) at 23 m/s (52 mph) Warranty and Certifications Warranty 25 year limited power warranty 10 year limited product warranty Certifications IEC 61215, Safety tested IEC 61730 UL listed (UL 1703), Class C Fire Rating Dimensions nun rri IF 1� 1200 4.2 C16 2X04.2 6161 IGa�41 + "1 754 129.691 4 91s 2X2 �f �1I ®Ie6.61.26) (36.0521 112.69) �1 11:11 "' 04.21161 lc ­ l CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Go to www.sunpowercorp.com/panels for details About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. ® October 2007 SunPower Corporation. All rights reserved. Specificctions included in this datasheet are subject to change without notice. Document #001.42188 Rev %0 Printed on paper d e recr cla p p www.sunpowercorp.com BENEFITS Reliable and Robust Design Proven track record for durability and longevity High Efficiency Weighted CEC efficiency over 95% and peak efficiency over 96% Reduced Installation Cost Integrated DC disconnect with fuses lowers material costs and labor requirements Attractive Aesthetics Integrated disconnect eliminates need for visible conduits to inverter Ideal Output Ideal for residential applications 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE The SunPower inverters 3000m and 4000m provide exceptional reliability combined with superior performance. Innovative design and advanced testing have been brought together to create a durable inverter that enables optimal system performance over the long term. Both models come with a standard 10 -year warranty. SPR -3000m and SPR -4000m www.sunpowercorp.com 3000m & 4000m INVERTERS EXCEPTIONAL RELIABILITY AND PERFORMANCE Electrical Data Shipping Dimensions W x H x D inches 23.5' x 18.5' x 16.0' SPR -3000m SPR -4000m AC Power 3000 W 3500 W @ 208 V / 4000 W @ 240 V AC Maximum Output Current (@ 208Vr 240V) 15A, 12.5A 17A, 16.6A AC Nominal Voltage Range 183-229V@208 VAC 211 - 264 V @ 240 VAC 183-229V@208 VAC 211- 264 V @ 240 VAC AC Frequency /Range 60 Hz / 59.3 Hz - 60.5 Hz 60 Hz / 59.3 Hz - 60.5 Hz Power Factor 1 1 Peak Inverter Efficiency 96.6% 96.8% CEC Weighted Efficiency 95.0 %@ 208 V 95.5 % @ 240 V 95.5 %@ 208 V 96.0 % @ 240 V Recommended Array Input Power (DC @ STC) 3600 W 4800 W DC Input Voltage Range 200 -500 V @ 208V 200 - 500 V @ 240V 250-600 V @ 208 VAC 250 - 600 V @ 240 VAC Peak Power Tracking Voltage g g 180 - 400 V @ 208 VAC 200 - 400 V @ 240 VAC 220 - 480 V @ 208 VAC 250 - 480 V @ 240 VAC DC Max. Input Current 17 A 18A DC Voltage Ripple <5% No. of Fused String Inputs 4 Power Consumption: Standby / Nighttime <7W/0.1 W Fused DC Disconnect Standard; Complies w NEC Standards Grounding Positive Ground SPRrn Efficiency Curves 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% % of Rated Output Power Mechanical Data Shipping Dimensions W x H x D inches 23.5' x 18.5' x 16.0' Unit Dimensions W x H x D inches 17.8'x 13.8'x 9.3' Inverter Weight 88 lbs Shipping Weight 94 lbs Cooling Forced Air / Sealed Electronics Enclosure Enclosure NEMA 3R Mounting Wall Mount Bracket Standard Ambient Temperature Range -13 to +113 °F Warranty and Certifications Warranty 10 year limited warranty Compliance: IEEE -929, IEEE -1547, UL 1741-2005, Certifications UL 1998, FCC Port 15 A & B U About SunPower SunPower designs, manufactures and delivers high-performance solar electric technology worldwide. Our high -efficiency solar cells generate up to 50 percent more power than conventional solar cells. Our high-performance solar panels, roof tiles and trackers deliver significantly more energy than competing systems. mJuns 2007 SunPower Corporation. All rights reserved. Specifications included in this dotosheet ore subject to change without notice. Document b 001-16966, Rev •• www.sunpowercorp.com SORARMOUNT. Installation with Top Mounting Clamps Installation Manual 201.1 U.S. Des. Patent No. D496,2485. Other patents pending. This manual details the No. of procedure for flush mounting %- footing SolarMount to a pitched roof. Rail length (inches) If your installation includes tilt legs, see also the instructions bolts shipped with the leg kit. 48-106 Contents 4 Installer reponsibility ...... 2 Laying out the 2 installation area ........... 2 Laying out L -feet .......... 3 Installing L -feet ........... 3 Laying out standoffs ....... 4 Installing standoffs ........ 4 Installing SolarMount 10 rails ..................... 5 Installing the modules ..... 6 Part quantities 12 SolarMoune Rail Sets T -bolt slot for module Footing boli slot Top Mounting Clamp Sets, Sizes A -F, GO% Ht, and ) Modules End Mid Y4" module No. of Y4- flange %- footing Ye" flange Rail length (inches) rails L -feet bolts nuts 48-106 2 4 4 4 120-180 2 6 6 6 192-216 2 8 8 8 226-288 (w/ splice) 2 10 10 10 300-336 (w/ splice) 2 12 12 12 348-408 (w/ splice) 2 14 14 14 420-432 (w/ splice) 2 , 16 16 16 Top Mounting Clamp Sets, Sizes A -F, GO% Ht, and ) Modules End Mid Y4" module Y4 -x%" Y4- flange per row clamps clamps Tboks -- safety bolts nuts 4— 2 -- -- 6 --- 2 2 —•- 8 - 3 4 4 8 2 10 4 4 6 10 212 5 4 8 12 2 14 6 4 10 14 2 16 7 4 12 16 2 18 8 4 14 18 2 20 9 4 16 20 2 22 10 4 18 22 2 24 II 4 20 24 2 26 12 4 22 26 2 28 * In size G, end clamps and mid clamps are identical, except that end clamps include spacers. For illustration, see page 14. f In size H, end clamps and mid clamps are identical Hexheod bolts replace T -bobs. For illustration, see page 14. Figure 3. Exploded view of a low -profile installation mounted flush to the roof with L feet. Wrenches and torque Wrench Recommended size torque (ft -lbs) Y4" hardware '/e" Is '/a" hardware '/6 30 UniRac welcomes input concerning the accuracy and user friendliness of this publication. Please write to publications@unirac.com. Stainless steel hardware can seize up, a process called galling.To significantly re- duce its likelihood, (1) apply lubricant to bolts, preferably an anti -seize lubricant, available at auto parts stores, (2) shade hardware prior to installation, and (3) avoid spinning on nuts at high speed. See Installation Supplement 910, Galling and hs Prevention, at www.unirac.com. t ' © 2005 by UniRac, Inc. All rights reserved. NMACO Installation Manual 201.1 Installer responsibility The installer is solely responsible for: • Complying with all applicable local or national ' building codes, including any that may supercede this manual; • Ensuring that UniRac and other products are ap- propriate for the particular installation and the installation environment; • Ensuring that the roof, its rafters, connections, and other structural support members can sup- port the array under building live load conditions. i Low -profile High-profile mode mode JIJT i Lower roof edge Figure 4. Rails may be placed parallel or perpendicular to rafters. SolarMountO Top Mounting • Using only UniRac parts and installer -supplied parts as specified by UniRac (substitution of parts may void the warranty); • Ensuring that lag screws have adequate pullout strength and shear capacities as installed; • Maintaining the waterproof integrity of the roof, including selection of appropriate flashing; and • Ensuring safe installation of all electrical aspects of the PV array. Laying out the installation area The installation can be laid out with rails parallel to the rafters (high-profile mode) or perpendicular to the rafters (low -profile mode). Note that SolarMount rails make ex- cellent straight edges for doing layouts. Center the installation area over the rafters as much as possible. Leave enough room to safely move around the array during installation. The width of the installation area is equal to the length of one module. The length of the installation area is equal to: • the total width of the modules, • plus 1 inch for each space between modules (for mid -clamp), • plus 3 inches (11/2 inches for each set of end clamps). 10 year limited Product Warranty, 5 year limited Finish Warranty UniRac, Inc., warrants to the original purchaser ('.'Purchaser') of product(s) that it manufactures ("Product') at the original installation site that the Product shall be free from defects in material and workmanship for a period often (10) years, except for the anodized finish, which finish shall be free from visible peeling, or cracking or chalking under normal atmospheric conditions for a period of five (5) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser ("Finish Warranty"). The Finish Warranty does not apply to any foreign residue deposited on the finish. All installations in corrosive atmospheric conditions are excluded.The Finish Warranty isVOID if Nye 2 the practices specified byAAMA 609 & 610-02 "Cleaning and Maintenance forArchitecturally Finished Aluminum" (www.aamanet.org) are not followed by Purchaser.This Warranty does not cover damage to the Product that occurs during its shipment, storage, or installation. This Warranty shall beVOID if installation of the Product is not performed in accordance with UniRac's written installation instructions, or 9 the Product has been modified, repaired, or reworked in a manner not previously authorized by Unillac IN WRIITING, or if the Product is installed in an environment for which it was not designed. UniRac shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by Purchaser under any circumstances. If within the specified Warranty periods the Product shall be reasonably proven to be defective, then UniRac shall repair or replace the defective Product, or any part thereof, in UniRac's sole discretion. Such repair or replacement shall completely satisfy and discharge all of UniRac's liability with respect to this limited Warranty. Under no circumstances shall UniRac be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product Manufacturers of related items, such as PV modules and Flashings, may provide written warranties of their own. UniRac's limited Warranty covers only its Product, and not any related items. Installation Manual 201.1 Laying out L -feet L -feet (Fig. 5) are used for installation through existing roofing material, such as asphalt shingles or sheet metal. Use Figure 6 or Figure 7 below to locate and mark the L -feet lag bolt holes within the installation area. Consult UniRac's SolarMount Code -Compliant Planning and Assembly to determine foot spacing that o-vill meet code. Download the version for theapplicable building code at www.unirac.com. In low -profile layouts, stagger feet on rafters (Fig. 7) to distribute the load. If multiple high-profile rows are to be installed adjacent to one another, it will not be possible for each row to be centered above the rafters. Adjust as needed, following the guidelines in Figure 7 as closely as possible. 25% typical each end .I I 13/4'-� r+- I ql l T' Lower roof edge J E I il' I t� Rafters Figure 7. High-profile layout SolarMount® Top Mounting UNMRACO Figure 5 _ Overhang— ��- Foot ,t—spacing 13/a" - - 6 $ 4 1�% I Lower roof edge I r Figure 6. Lore -profile layout 50% typical 13/4' t I Fool Il\ � i 'ij _f spacing I / I ,-: I' Overhang Installing L -feet Stagger feet on rafters 25% typical Ieach end 50% typical _y Drill pilot holes through the rocf into the center of the rafter at each L -foot lag bolt hole location. Consult procedural step 6 and Table 4 (p. 8) in SolarMount Code Compliant Planning andAssembly to select the lag bolts that meet building code wind load requirements. Lag bolts are not provided with SolarMount rail sets. Apply sealant into the hole, and on the shafts of the lag bolts. Seal the underside 'of the L -feet with a suitable weatherproof sealant. Securely fasten the L -feet to the roof with the lag bolts. Ensure that the L -feet face as shown in Figure 6 or Figure 7. The single -slotted square side of the L -foot must always be against the roof with the double -slotted side perpendicular to the roof. - hp 3 Installation Manual 201.1 SolarMount® Top Mounting WRAC' Laying out standoffs Standoffs (Fig. 8) are used for flashed installations, such as those with file and shake shingles. Use Figure 9 or Figure 10 to locate and mark the standoff lag bolt holes within the installation area. Consult UniRac's SolarMount Code -Compliant Planning and Assembly to determine foot spacing that will meet code. Download the version for the applicable building code at www.unirac.com. Remove the tile or shake underneath each standoff location, exposing the roofing underlayment. Ensure that the standoff base lies flat on the underlayment, but remove no more material than required for the flashings to be installed properly. Use the standoff base as a template to mark lag bolt hole locations on underlayment above the center of the rafters (Fig. 9 or Fig. 10). In low -profile layouts, stagger standoffs on rafters (Fig. 9) to distrib- ute the load. When determining the distance between the rails in high-profile mode, keep in mind that the center of each rail will be offset from the standoff lag bolt holes by '/16 of an inch. If multiple high-profile rows are to be installed adjacent to each other, it will not be possible for each row to be centered above the rafters. Adjust as needed following the guidelines in Figure 10 as closely as possible. Figure B. SolarMount standoff choices: alumi- num 2 -piece (left), steel flat -top (center), and steel raised flange. 7Wo-piece standoffs allow flashings to be precisely placed over bases pri- or to installation of the standoff itself. Raised flange standoffs do not require L feet. OverhangFoot spacing -^ ` ' \ j 25% typical each end 13/a" i �H+` ✓ ,, ; 1 50% typical e Lower roof edge -- — Stagger standoffs on rafters Figure 9. Low -profile layout 25% typical 5076 typical each end l� ` 7/16" i 1 %��� i • I' .I �;� ., •:) � � ; �� Foot Y 7 spacing i I I Figure B. SolarMount standoff choices: alumi- num 2 -piece (left), steel flat -top (center), and steel raised flange. 7Wo-piece standoffs allow flashings to be precisely placed over bases pri- or to installation of the standoff itself. Raised flange standoffs do not require L feet. OverhangFoot spacing -^ ` ' \ j 25% typical each end 13/a" i �H+` ✓ ,, ; 1 50% typical e Lower roof edge -- — Stagger standoffs on rafters Figure 9. Low -profile layout 25% typical 5076 typical each end l� ` 7/16" 1 %��� i • I' .I �;� ., •:) � � ; �� Foot spacing i I I Lower roof edge II I Overhang y Rafters Figure 10. High-profile layout Installing standoffs Drill 3/ie-inch pilot holes through the underlayment into the center of the rafters at each standoff location. Securely fas- ten each standoff to the rafters with the two 5/x' x 31/2' lag bolts provided with it. Verify that the lag bolts you use are adequate for your installa- tion by following procedural steps 4A or Q (pp. 5, 8) in SolarMount Code -Compliant Planning and Assembly. If you are using raised -flange standoffs, ensure that they face as shown in Figure 9 or Figure 10. Steel flattop standoffs should also be lagged at oppo- site corners. SolarMount steel standoffs are designed for installation with collared flashings available from UniRac. Aluminum flashings take all metal flashings, also available from UniRac. Install and seal flashings and standoffs using standard build- ing practices. ftR 4 NM C''. installation Manual 201.1 Figure 11. Splice bars slide into the footing bolt slots of SolarMount rail sections. Aligning the Rail Ends. . Align one pair of rail ends to the edge of the instal- lation area (Fig. 13 or Fig. 14). The opposite pair of rail ends will overhang the side of the installation area. Do not trim them off until the installation is complete. In low -profile mode (Fig. 13), either end of the rails can be aligned, but the first module must be installed at the aligned end. 1 i 1 i' 1 Edge of installation area Figure 13. Low -profile mode SolarMount° Top Mounting Installing SolarMount rails Keep rail slots free of roofing grit or other debris. Foreign matter will cause bolts to bind as they slide in the slots. Installing Splices. If your installation uses SolarMount splice bars, attach the rails together (Fig. 11) before mounting the rails to the foot- ings. Use splice bars only with flush installations or those that use low -profile tilt legs. If using more than one splice per rail, con- tact UniRac concerning thermal expan- sion issues. Mounting Rails on Footings. Rails may be attached to either of two mounting holes in the footings (Fig. 12). Mount in the lower hole for a low profile, more aesthetically pleasing instal- lation. Mount in the upper hole for a higher profile, which will maximize airflow under the modules. This will cool them more and may enhance performance in hotter climates. Slide the %-inch mounting bolts into the footing bolt slots. Loosely attach the rails to the footings with the flange nuts. Ensure that the rails are oriented to the footings as shown in Figure 6, 7, 9, or 10, whichever is appropriate. Edge of installation area Figure 14. High-profile mode For the safest high-profile installation (Fig. 14), the aligned end of the rails must face the lower edge of the roof. Securely tighten the flange nuts on the mounting bolts after alignment is complete (28-32 ft lbs). Mount modules to the rails as soon as possible. Temperature changes may bow the rails within a few hours if module placement is delayed. Por 5 UNC Ca Installation Manual 201.1 Installing the modules Prewiring Modules. If modules are the Plug and Play type, no prewiring is required, and you can proceed directly to "Installing the First Module" below. If modules have standard J -boxes, each module should be prewired with one end of the intermodule cable for ease of installation. For safety reasons, module prewiring should not be performed on the roof. Leave covers off J -boxes. They will be installed when the modules are installed' on the rails. Installing the First Module. In high-profile installations, the safety bolt and flange nut must be fastened to the module bolt slot at the aligned (lower) end of each rail. It will prevent the lower end clamps and clamping bolts from sliding out of the rail slot during installation. If there is a return cable to the inverter, connect it to the first module. Close the J -box cover. Secure the first module with T -bolts and end clamps at the aligned end of each rail. Allow half an inch between the rail ends and the end clamps (Fig. 15). Finger tighten flange nuts, center and align the module as needed, and securely tighten the flange nuts (15 ft lbs). Installing the Other Modules. Lay the second module face down (glass to glass) on the first module. Connect intermodule cable to the second module and close the J -box cover. Turn the second module face up (Fig. 16). With T -bolts, mid clamps, and flange nuts, secure the adjacent sides of the first and second modules. Align the second module and securely tighten the flange nuts (Fig. 17). For a neat installation, fasten cable clamps to rails with self -tapping screws. Repeat the procedure until all modules are installed. Attach the outside edge of the last module to the rail with end clamps. Trim off any excess rail, being careful not to cut into the roof. Allow half an inch between the end clamp and the end of the rail (Fig. 15). Check that all flange nuts on T -bolts are securely fastened. t 1 � . High -lipped module (cross section) "Spacer So'arMount rail with G clamps and spacer SolarMount® Top Mounting Module i �tframe /2" minimum I/4" module bolt and flange nut End clamp Roil to Figure 15 "N ZJ-boxes Figure 16 Module Frames 4" module bolt and flange nut X. Mid clamp Figure 17 Low -lipped module (cross section) 3�. G;_.4_Wt3 .i �4�iE_J Ys.., SolarMount rail with Size H clamps--� Figure 18. Size G clamps (for modules with high lips) ules with low lips) are identical and employ hexhead include a spacer for the end clamps but are otherwise bolts in place of T -bolts; their heads slide into Solar - identical. Size H mid clamps and end clamps (for mod- Mount® rails. °"` UniRac, Inc. 3201 University Boulevard SE, Suite 110 505.242.6411 6 www.unirac.com Albuquerque NM 87106-5635 USA 505.242.6412 Fax