Loading...
HomeMy WebLinkAbout039-460-056Building Permit Number: d3_ 311 Owner Name: Xn a zvl-e,4 Residential Construction Requirements IMPORTANT This set of plans and specifications MUST be kept on the job site at all times and it is unlawful to make any changes or alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship shall be in accordance with recognized good practices and of a quality prescribed for the specific use in the 2001 California Building Code (2001 U.B.C), 2000 California Plumbing Code ( 2000 U.P.C.), 2000 California Mechanical Code (2000 U.M.C.) and the 1999 California Electrical Code (1999 N.E.C.) COMPLY WITH ITEMS CHECKED BELOW ;M Your parcel lies within a designated 100 -year flood plain. Finish floor, electrical, H.V.A.C. equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required Note: We will normally accept the following as compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24" above grade, or engineered design required). 3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than 1 foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. Page 2of2 Building permit Number: 03—_5/ Owner Name: Knnolu-"o /Y 19 requirements. Parcel lies Within the State Responsibility Area (SRA). Comply with attached M9 Fire sprinklers are required in this structure. The f0llOwing Parcel map requirements shall be met: . . . . ....... ....... . ...... ... . All structures and equipment including 9 OvClh-angs shall be clear of all easements. A setback of -6— feet from the side and —a feet from ght oarpolines and 20feet (25 feet if Federal Aid Route) from the edgeof the rf way shall be clear of structures and equipment except for a 2 foot overhang. Expansive soil may be encountered on this site. This condition may requi th foundation to be designed by a California registered en * r e e edition or licensed architect. u -- _ .; ;• ._ offs couftfq LAND OF NATURAL WEALTH AND BEAUTY Y i, of ;; .,,•�Y... BUILDING DIVISION •;:.,z;,,��.r .{ � . ;� , ; ,, ;: •, DEPARTMENT OF DEVELOPMENT SERVICES `� ` ;,' •''j'. ' 7 COUNTY CENTER DRIVE • OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (530) 535-7541 October 6, 1999 FAX: (530) 538-2140 Re: Swimming Pool Safety Act Clarification Of Enforcement In Butte County Effective Date: January 1, 1998 To Whom It May Concern, In December of 1997, just prior to the effective date of the Swimming Pool Safety Act, (see back page) we initiated a letter of explanation, and a mailing to all pool contractors in Butte County. Due to the poor wording of the Act itself, a number of questions have arisen concerning compliance with the Act and how to enforce it. We have revised our letter to describe how enforcement will occur in Butte County, and are again conducting a mailing to notify pool contractors. This revised letter should clarify several common questions or problems concerning our enforcement of the Swimming Pool Safety Act including: 1. In our review of legislative considerations, we discovered that when accommodation was provided to allow exit alarms on doors providing direct access to the pool, it was assumed that a conforming perimeter fence was already in place. However, in many cases there is no pre-existing pool or parcel enclosure, and unless the residence is one side of an enclosure which entirely surrounds the pool, installation of exit alarms alone does not constitute compliance. 2. The 1994 Uniform Building Code, Appendix Chapter 4, Division 1, and the 1997 Uniform Building Code, Appendix Chapter 4, Division 1, specifically allow the use of chain link fencing. as pool barrier material. In Butte County we will continue to allow the use of 11 gage, 2-1/4 inch mesh, chain link fencing as pool barrier material. Other types of fencing will be considered on a case by case basis, based upon the requirements of the Swimming Pool Safety Act. Please call for clarification prior to installation. 3. All access gates through the enclosure shall open away from the swimming pool, and be self- closing with a self -latching device placed no lower than 60 inches above the ground. This includes large gates for vehicle access. Should you have further questions concerning this matter, please contact this office at the address or phone number listed above. Sincerel*Mzger,'iBui'1'Mng C.B.O. Inspection CALIFORNIA HEALTH AND SAFETY CODE SECTION 115920-115927 115920. SWUY21ING POOL SAFETY ACT 115921. As used in this article the following terms have the following meanings: a) "Swimming pool" or "pool" means arty structure intended for swimming or recreational bathing that contains water over 1: inches deep. "Swimming pool" includes in -ground and aboveground structures and includes, but is not limited to, hot tubs, spas, portable spas, and non-portable wading pools. b) "Public swimming pool" means a swimming pool operated for use of the general public with or without charge, or for the use of the members and guests of a private club. Public swimming pool does not include a swimming pool located on the grounds of a private single-family homes. c) "Enclosure" means a fence, wall, or other barrier that isolates a swimming pool from access to the home. d) "Approved safety pool cover" means a manually or power -operated safety pool cover that meets all of the performance standards of the American Society for Testing and Materials (ASTM), in compliance with standard F1346-91. e) "Exit alarms" means devices that make audible, continuous alarm sounds when any door or window, that permits access from the residence to the pool area that is without any intervening enclosure, is opened or is len ajar. Exit alarms may be battery operated or may be connected to the electrical wiring of the building:. . 115922. Commencing January 1, 199:, except as provided in Section 115925, whenever a construction permit is issued for construction of a new swimming pool at a private single-family home it shall be equipped with at least one of the following safety features: a) The pool shall be isolated from access to a home by an enclosure that meets the requirements of Section 115923. b) The pool shall be equipped with an approved safety pool cover. c) The residence shall be equipped with exit alarms on those doors providing direct access to the pool. d) All doorsproviding direct access from the home to the swimming pool shall be equipped with aself-closing, self Iatching device with a release mechanism placed no lower that 54 inches above the floor. e) Other means of protection, if the degree of protection afforded is equal to or greater than that afforded by any of the devices set forth in subdivisions a) to d), inclusive, as determined by the building official of the jurisdiction issuing the applicable building permit Any ordinance governing child access to pools adopted by a political subdivision on or before January 1, 1997, is presumed to afford protection that is equal to or greater that afforded by any of the devices set forth in subdivisions a) to d), inclusive. 115923. An enclosure shall have all or the following characteristics: a) Any access gates through the enclosure open away from the swimming pool, and are self-closing with a self -latching device placed no lower than 60 inches above the ground. b) A minimum height of 60 inches. c) A maximum vertical clearance from the ground to the bottom of the enclosure of two inches. d) Gaps or voids, if any, do not allow passage of a sphere equal to or greater that four inches in diameter. e) An outside. surface free of protrusions, cavities, or other physical characteristics that would serve.as handholds or footholds that could enable a child below the age of five years to climb over. 115924. Any person entering into an agreement to build a swimming pool shall give the consumer notice of the requirements of this article. 115925. The requirements of this article shall not apply to any of the following: a) Public swimming pools. b) Hot tubs or spas with locking safety covers that comply with the American Society for Testing Materials -Emergency Performance Specification (ASTM ES 13-:9).,- c) Any pool with the jurisdiction of any political subdivision that adopts an ordinance for swimming pool safety that includes requirements that are at least as stringent as this article. d) An apartment complex, or any residential setting other than a single-family home. 115926. This article does not apply to any facility regulated by the State Department of Social Services even if the facility is also used as the private residence of the operator. Pool safety in those facilities shall be regulated pursuant to regulations adopted thereof by the State Department of Social Services. 115927. Notwithstanding any other provision of law, this article shall not be subject to further modification or interpretation by any regulatory agency of the state, this modification or interpretation by any regulatory agency of the state, this authority being reserved exclusively to local jurisdictions, as provided for in subdivision (e) of Section 114922 and subdivision (c) of Section 115924. -t-30-0 175.5 125.5 PLA.` NING DIVISION - BUILDING PLAN AIJFKUVAL > Date: 10` N 0-0 Far":- Landscaping: N090202 5 00 �jj I TDW A:�- C©v�s Pjm5 are, 4-o b-v— �� a�� c�nspe�k� `tea GENERAL SPECIFICATIONS' SIZE 2©x40 AREA 9A 4 Ef DEPTH -316—TO 7V SHAPER EC TA KrG LE PERIMETER 160 TEMPLATE NO. CUSTOM ealth ELECTRICAL, MECHANIOAL, AND PLUMS )ING TILE SIZE x 6 �2��MA CONSTRUCTION ( NOT PLAN CHECKED ) SHALLCOMPLY V41TH CURRENT EDIT04 TILE COLOR 0 T OF NEC, UMC AND UPC. 18�'RAISEQ LOUNGE COPING NO AREA COPING COLOR N 0 POOL CAPACITY '3rajo 00 GALS. STE P PUMP CAPACITY 110 G.P.M. 0 STEPS MOTOR H.P. 112 H.P. FILTER GO SO. FT. 0 FILTER RATE 110 G.P.M. TURNOVER G HRS. VACUUM LINE & SKIMMER 2 ()C� BENCH RETURN LINE 15*4- NOT E: 0 MAIN DRAIN Soe the attfach-ed SKIMMER - MODEL U-3 40'd BACKWASH To D (S LINE 20 OF 1,12" FILL LINE <-4 21 L16H T ANTI -SYPHON VALVE AUTO ELLL _ _Pages V�50O�- HEATER SIZE N 0 BTU GASLINE BY: NO VENTED BY: 0 )y NI/ LIGHT 50 0 (W) I 6o (WJ -SWIMOUT 121 CLOCK 22-0 (v) lo. LIGHT ELECTRIC BY: C F, p (00(W) ELECTRICAL BONDING BY: C , F, P STEPS/BENCHES I POOL CLEANER POO ,L -VAC CHLORINATOR NO PATIO _(E) BOARD -SIZE N 0 COLOR No ,_.SARAANN CT1__ BOARD SUPPORTS- NO DECK DRAIN <; DECK ROCK—SALT LADDER -Model NO SLIDE -#N _0C*I*r____-Y_ RESIDEMCF - STUB PLUMB 0 YES VN o BU17EE GOUNI TILE L COPING ID1 ASAP 0 OTN TMC BUILDING DEPAR I DECK BY: C F P OWNERO. p P R V TREES, ETC. NO CONCRETE REMOVAL BY: N TO DETERMINE APPROXIMATE ELEVATION SCALE •1/8" 1, 0, PERMIT OFFICE ON L NOTE SALES OFFICE MAISEDPND BEAM: OF POOL DAY OF EXCAVATION. YES NO 0 HEIGHT- 18fl WIDTH 1211 PLASTER G REY it- PHONE NO. MGR. OWNER: 310 5 NO. SALESMAN POOL AREA TO BE FENCED, PER COUNTY PO SSIBLE PEBBLE -TEC MAP BOOK NO. I DATE OR CITY ORDINANCE. GATES TO BE SELF SWIMMING POOL CLOSING AND SELF LATCHING. BY OWNER LEGAL DESCRIPTION NAME TOM AND SARA KNOWLES AP 039 -460 -05ro OWN. BY 85 SARA ANN CT PLAY AREA 12_X1?_ 144 Ica FT ADDRESS92 OWNER: DURHAM WET DOWN CONCRETE SHELL AT LEAST TWICE DAILY FOR 7 DAYS. LOT NO: CROSS STREETS DO NOT TURN ON POOL LIGHT WHEN POOL C WO. BY IS EMPTY. TRACT N0. DONOT USE RUBBER HOSE WHEN FILLING RES. PHONE 5946025 BUS. PHONE 342-6196 POOL AS IT WILL MARK PLASTER. BOOK —PAGE —BLOCK MAILING ADDRESS — PRINTS CARE -FREE POOLS S_ #9 Alyssum Way C_ Chico, California 95928 tsm Bell Contr. Lic. #38082'6 Phone 342-4639 �^ s I � -��� .. � y t ;: ..,_. � i � 1 I I � I i I li I r �� r t � -���