Loading...
HomeMy WebLinkAbout039-460-066BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAM (530)538-2140 WEBSITE: www.buttecounty.net\dds PERMIT NO. BP040940 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 01/27/2005 APN • 039-460.066-000 the Business and Professions Code, and my license is in full force and effect. License Class: Liic�enseN�u'm`b�er: Site Address: 2469 TRACY RANCH RD DUR /" Date: q_& _0q Contractor: D;f 1 L*A Map Index: Description: NSF(3650)GAR(1071)COV(948)OPEN(453) OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a Owner: WEBB BILL permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a 1814 CAPSTONE CT signed statement that he or she is licensed pursuant to the provisions of CHICO CA the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or 95926-9604 sheds exempt therefrom and the basis for the alleged exemption. Any violation of Section -7031.5 by any applicant for a permit subjects the applicant to a, civil,penalty.of not more than five hundred dollars ($500).): ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not -.intended or offered for sale (Sec. 7044, Business and Professions Code: TFie Contractors' S ate License Law does not apply to an Applicant: WEBB BILL. - owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). as.,gwner,,pf, the. proRe.ty,.,am..exclusively. contracting with licensed contractors to.construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does Contractor: not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I am Exempt under Article 3(of the Business and Code Date: :k of f.Professions v I I k Qb � Owner: License #: WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and Will maintain a certificate of consent to self -insure for „• „-„ workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Architect: is issued. ❑ '"I have and will maintain workers' co"mpensatidn insurance, as Engineer: VERTICAL TECHNOLOGY.ENGINEERING......_.. g required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurancecarrier and policy number are:. Carrier._ yra, %7---T—VAY P Total Square Ft: 6122 S.F. Valuation: $282,652.00 Policy M. Z ,& ❑ I certify itiat 1; performance. of the work for which this permit is Census Code: issued, I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwithcomply with those provisions. // Date: Applicant:Zoo WARNING: Failure' to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), in addition to the cost of g2g2 compensation, damages as provided for in Section 3706 of the Labor r C ('! I VVV code, interest, and attorney's fees. _ NS+. U_=;: , LENC—C- `ENCY' tis p -?"it is her.h,, i— ort , na .pepplicahlp nm isinns of the RnttP f'nunfv (nr1P and/nr . I hereby affirm that there is a construction lending agency for the Res lution o do work indicat d ab ve for which fees have been paid. - performance of the work for which this permit is issued (Sec 3097 Civ.) Name: BY Date: !!!',Q PERMIT EXPIRES ON: Z-2 7-66q, Date Address: ❑ " I hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte County to enter upon the above mentioned property for inspection purpose Print Name: !_� /�! Signature: / Date: 0 OLney l `12J_fA0tractor ❑ Agent for Owner ❑ Agent for Contractor National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement [LESS THAN 1 ACREI Project Title: Z -OT /�)v a)j)W (Aej O By signing below, I, the project owner/owner's agent, certify that I am aware that a construction project that disturbs 1 acre or more of land requires a Construction Storm Water Permit from the State Water Resources Control Board and that it is my responsibility to submit a Notice of Intent (N.O.I.), a Storm Water Pollution Prevention Plan (SWPPP), and a check for $700.00 made payable to the State Water Resources Control Board to obtain such a permit if my project disturbs 1 acre or more of land. I, further, certify that this project will not disturb 1 acre or more of land. I am aware that submitting false and/or inaccurate information may result in revocation of grading and/or other permits or other sanctions provided by law. Signed: Title: Date: NPDES & SWPPP Non -Compliance Certification Butte County Storm Water Management Program Revised 7/07103 COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: Wek I ASSESSOR PARCEL NUM E' v ~ q(, p Proposed Building Use: 1 v ✓ / G Counter Technician: Date: t r / Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order Eo apply. 1'1Site plans, 3 or 4 sets, signed by the preparer of the plans. r /El /12. Complete plans, 3 or 4 sets, signed by the preparer of the plans. L3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. 4. Engineered truss details and layouts in duplicate. No faxes! 5. Letter from Engineer or Architect for truss design review. 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate ❑ 11. Site plan and business license approval from the City of Biggs ❑ 12. Letter of intent for non-residential buildings ❑ 13. Detached Accessory Building Form filled out by the owner l _ 14. Hazardous Material Form 15. Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable. ❑ 16. Other I , I have been informeoo the above items andJrequirements for obtaining a building permit. 1. Index permit applicati or the above items numbered %_P 11 Plan Cfieck Letter 2. Additional item egwred 64 Contractor, designer, owne was advised of the above data by phone, ❑ mail, ❑ counter, b Date: ag Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: Date: Plans approved by: Date Structural reviewed by:� Date: Structural approved by: Date: �`. Note transfer by: r!t: Date: 101i Yellow: Building Division A tx.� Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ❑ 1709 . Fire Sprinklers............................................................................................ 18. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by 19. Soils Report and/or Engineered Foundation required ........................................... ........ ❑ / 20. Erosion Control Plan Required........................................................................ ........ C®Fees as shown on the attached Schedule of Fees Due Sheet .............................. ❑ 22. City of Chico Plumbing permit........................................................................ ❑ 23. California Department of Forestry plan approval ❑ paid. Sent by: ............. 24. Planning approval (A) Use:` (B)Parking: (C) Parcel Check: ` ❑ 25. Contact Land Development about _ Improvements, _ Drainage ......................... NPDESForm............................................................................................. 27 ncroachment Permit for driveway from the Public Works Dept ........................... 28. Pre -Inspection for required....... ❑ 29. Contractor's license information. (Number, Name Style, Classification) ................... g _ 30. Worker's Compensation Carrier and Policy Number ................................. ........ 31. Owner r -Builder Verification (_ Given to owner, _Mailed to owner) ..................... Letter of Signature authorization.................................................................... 33 ecorded copy of Agricultural Acknowledgment Statement ................................. (� ❑ 34. Manufactured home utility clearance............................................................... ❑ 35. Existing violations and/or expired permits......................................................... ❑ 36. Deed Restriction......................................................................................... ❑ 37. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑. , 38. Other: ❑ 39. Other: When issued Telephone and hold for pickup. I have been informeoo the above items andJrequirements for obtaining a building permit. 1. Index permit applicati or the above items numbered %_P 11 Plan Cfieck Letter 2. Additional item egwred 64 Contractor, designer, owne was advised of the above data by phone, ❑ mail, ❑ counter, b Date: ag Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: Date: Plans approved by: Date Structural reviewed by:� Date: Structural approved by: Date: �`. Note transfer by: r!t: Date: 101i Yellow: Building Division 1 E.H. USE ONLY Plot Plan Attached Floor Plan Attachad—C;71 Sant to B.D. cc TO: ing Department FROM: Environmental Health SUBJECT: Sanitation Clearance Owner Location AP# Plan Approved for: Sewage Disposal >r Water Supply: Public --*- Private Well Clearance for Other Hold final for: Final clearance O.K. for: NOTE: vironmental Health 8/96 ialist Date COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES — BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 TELEPHONE (530)538-7541 Wt �j SCHEDULE OF RECEIPT OF FEESOWNER "' 6l � I'� I PROPROS UILDING USE I. .BUILDING PERMIT FEES --- Balance Due ..................... $ --- Additional Fees Due........... -- evised Plan Checking Fee.... $ j� I d Oki SCHOOL DISTRICT FEES Vyl�nn (I V, / (paid at School Distric Offic) form available after 3. SHERIFF FEES (paid at Building Division) 0,0 Residential............ X $360.00 =$� Units Commercial (sq. ftg.)..... X $0.03 = $ Sq.Ftg. 4. URBAN AREA FEES A.P. # (. c� DATE % �/ — J RECEIPT # DATE REC. (paid at Building Division) Residential (per unit)..... X = $ if Units Amt. Commercial (Sq. Ftg.).... X = $ Sq. Fig. Amt. 6e 5. RECREATION DISTRICT FEES pxrkAlln (paid at Recreatio Dis tct Office) (form available a er.Plan Check) � �aP . 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK FEE $89.00 (paid at Building Division) 8. WATER TENDER FEES BATTALION # $200.00 (paid at Building Division) 9. NORTH CHICO SPECIFIC PLAN (paid at Building Division) Residential Zone X = $ Zone # Units Amt. Commercial (sq. ftg.) ......... X =$ Sq. Fig. a Amt. 10. OTHER S I / 1, A V'(� • At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the n checking process. L/ APPLICANT DATE I �� Pursuant to Government o e Section 66020, you are hereby notified that items, 2, 3, 4, 5, 6, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Division Yellow -Applicant Pink -Owner (rev. 2/2003) BUTTE COUNTY PARK FACILITY FEE PAYMENT CERTIFICATION FORM DURHAM RECREATION & PARK DISTRICT Assessor Parcel Number: 03C/ — ``t W — D (Q (P Property Owner():s 1 ` 1 Q ICU p Y V� Project Location/Address: � (I �O - rKa, . Project T Subdivision Name:'byK" J." Assessable Square Footage: 3(05—D Type of Residential Development (check one): New Development ❑ Alteration/Addition (� Mobile Home -Non-Reside Residenytial_K Comments: r' Durham Recreation and Park District (DRPD) certifies that S/S-z3a1�s Applicant Name Phone Number lZ� Vrilqws4g, �r. 61 c-0!. C{4 7S-5 7 3 Mailing Address , Has complied with the requirements of the Butte County Board of Supervisors Resolution No. 04-107 by payment for 3 (v50 square feet at $1.41 per ft. fora totaljpayment-of t4 D' epresentative Date Paid by Check No.: Remarks: Bank No.: qD- YZOZ _T_ Paid by Cash: _ Receipt No.: 2 106)q DISTRIBUTION: WHITE - APPLICANT PINK - DRPD YELLOW - BUTTE CO. BLDG. DIVISION BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) School District Building Department No. 0— 4 A.P. Number (0 Jurisdiction: city =EDCounty I Property Owner Property Location/Address -huy-v bz $ Subdivision a,* T l V�I.CJ- Lot No. Residential Development ........................................................... 4 ....................................... Sq. Footage 3 No of Living Mobile Home Addition) *Supplemental to (Group R) Units Installation Conversion Permit # ....................................................................... *(No foundation inspection) ! ....................... . .... Deed Restricted Sq. Footage (Attach a signed copy of Deed Restriction and Notice of Limited Use Facility document) I . �=Commercial/Industral Sc. Footage A New Addition (including Exterior f -I Building Department Representative District Identification No. 1611-297 J 'NJR OPI"-1 bW / -'-/ &-t> School District certifies that 5oofed Areas) 45—M �L Date I I 601 Webb (Applicant) 3336 (Street Address) (Phone Number) (City) (State) (Zip Code) has complied with the requirements of Resolution No. representing, School District Representative by payment of $ F/ 76 , square feet. JAB 2926 $ PFULL MMGATION $ Date Paid by Check # Remarks: Notlos: You may protest the Imposition of the fees Identified above by submitting a written protest to the District. In compliance with Government Code Section 66020(a). within 90 days from the date fen we paid. Failure to submit a timely written protest will'prohlbit you from challenging the Imposkfon of the fen In any court action, --.1f, subsequent to the School District Representative signing this Butts County Schools Impact Fee Certification Form, the School District Is by the applicable Local Planning Agency that this project Is being rovkiwed under the California Environmental Quality Act (CEPAh thlep M d may be subledto additional school lees to fully mitigate.ft Impact on the school districts schools. White (applicant), Yellow (building department), Pink (school district) feeform.As (10/03)dm.m AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 210m5-10121KD523-7 Recorded Official Records County Of Bulft CAND14CE J. BRUBBS Recorder ROSEMARY DICKSON Assistant 02:32PM 27 -Jan -2005 I REC FEE 7.00 1 COPIES 2,00 I 1 I 1 1 Kathy I Page i of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: �T 2S, AS S"owQ oti rA4�7- 6&w-r7j-vv A4Ak47, ��-rDUIt Z. WitiCA tM14$ W&S, �Cf�Ra�'sJ !N '�}� oFTfGE OF i7f� F T1+C 6vvv' pt= a3 S7 -47E- OF CAi-1r 0e-1V/lq, 01 ..1 V" 31 foo !/ ©t= mAf'S . A:r /' Date �-- OS PRAPE Y O WNEP S: • � 1 L l_ l/�� c�3iZ State of California ) County of ` U -H L ) On ,Jq 27 26057 before personally known to me (or proved to me on the asis of satisfactory evidence) to be the person(s) whose n(s) is/are subscribed to the within instrument and acknowledged to me thatOjeshe/they executed the same in er/their authorized capacity(ies), and that b�{liiller/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, execu ed the instrument. WITNESS my hand and official seal. - Signature /1 "Seal: AMBER(EAAGN /_ Nokwy ft �4Iae�elie A.P. # y 0 ®�C7 MV�.Oftfln. �i Butte County Department ofDevelopment Services -� r tF YVONNE CHRISTOPHER, DIRECTOR 7 County Center Drive O , Oroville, CA 95965 0 0 (530) 538.7601 Telephone CDU.N�y (530) 538-7785 Facsimile O TO: WILLDAN FROM: Scott Rutherford (530) 538-7160 srutherford(a)buttecou nty. net 1. SUBJECT: Plans Transmittal For Review Per Contract DATE: 07109/2004: AP, -A Certificate of Conforme an� Certificate 052736 ' THIS IS TO CERTIFY that the glued laminated timber products identified with ; Engineered Wood Systems (EWS) were a cone;.�,e mark of manufactured in accordance with the applica- and associated specifications indicated below ir standards ANSI Standard A-190.1-1992, For Wood Products- Structural Glued Laminated Timber NER-486 Glued Laminated Timber Combinations And "GAP" Computer Program For Determining Design Stresses RITC 117-93 - Manufacturing - Standard Specifications For Structural Glued Laminated Timber Of Softwood Species IT 1S HEREBY CERTIFIED that the APA. EWS trademarked structural.giu.ed laminated tirr-be, members • were produced in a manufacturing facility subject to regular audits in accordance witt, the Er-,gineered Woad Systema .(EWS)Quaiity Assurance Program. Routine audits include. insp cion of the manufacturing process and evaluation of the in -plant QA program with adequate sampling to verify confor/mance to industry. standards for lumber grade and giueline bond quality. 460 $f z E -AJ_-' All I ''meq---��a� �� °•�'�� 0 b y -- Thomas G. Williamsc„ Executive Vice Presidu-Ott EA'C("EERED vNODD SYSTCMS n e leieleo CO,Drnei�pn p) .qc�c ..fF %JGJiJ'- WOOD ASSOC 70, 1 Sou- gill Saeoi - RLQ. Box 11700, . _ T,ttAED Lt71pn- --- T^M+DSor,%r: (253) 56Z� stoma.. V-A Qe+ I1 -07p0 8000 - Fer Number. (753) 5&3.7265 Vc. fo..n (`o�mlt ((umtroc M;n%(a[lat;on corlCcjito is roquirod to Vo pos(od a( (ho bu;(ding Sao (+ror to tlw isSvAf•co or tho ootxrpancy pormil T)ur I Q a Ganem czlogor;os i4tod l»(ow aro tho "dual oquipmont'nQanod. Nolo may bo usod to moot thoso roquiromonts. n pp f anco s od on tho Iho c6cloncy and typo of lho appiianco inslaflod mus(bo oquivalont o! bonor than Ileo a(�' r pocaFt Con;l c•: CompGanoo (CF -M). This conit;c.210 (oras cquivAont) shat( bo propa(od and signod by po"on(s) assuming ovorall rosponsbiity for (ho appGznco inslaaatvn. 1- [ho undorsgnod• vorQy that tho oqugwnont Gstod to tho cItog<)cy abovo my s9natu(o is tho actual oquiprnont inslaltod a[• that (ho oqu;pmont moots or occoods tho roquiromonts of tho /1pp6anCo ErfoorxY $(an6ar6s. In ad�lon• (have vorifod tho oquipmon( is cquiva(ont to or Moro off;ciont than tho oquipmonl spo�o6 on tho Gort;fiCalo o(CompGarKo submatod 1, demonsualo cpmpfanco waft tho Enorgy Eff6ar-CY Standards for fcs;dont;al buildings. HVAC SYSTEMS (loco: Hydron;c boitor inform2tion is entered here. O:hor hydronc or combiicd hydronic cquipmont is listed undor Ylzlcr Hoating Sysloms- Hit ating Equip. CECCorttffQ Actua( 01strlb6tlon Duct or Hoating Load t(oat(n9 rypo (fumaco, f.(anuf. flako 4 Effldoncy Typo and PfpIng 60foro Ovor- Equipmont heatpump -etc.) fdoda(Numbar (f1WE,etc) Lout(on MIL SIz(ng(8tuh) Capachy{81 Gas -40 gal_ _5[Nc 35_000 — ScandaM PRV 40 NOCTO52 40 .62 1. Foedc"audaa a(or.p<(ratcdinptrtS7S000(iayhr)..iKtltct.a(.t.Lica:ndh.atpumpwat.Ch.alora,talEncrpyfaC:or. For carpo pa c atot.p. Kat.r h..t.ea (rated tnpu(s7S-000 Ott.A.11• rat hated G`wc n000wcy Et%oency and St>%dbfLott. Forza s to nt.[ a eotr c o < a Ka tee h e ctecs. Ct (Ratod lnp[r, and t%oo.ccr E(rooc-cy. F-oC(nctaa4aoovr ctectrtcw<t.r(rutda-ra(fiatC'QIK+u(. FAUCCTS 6[ SHOWER HCAOS All (aucatr 2nd showorhoadt tnrtatlod ala Gttod to [Ito comrntstori s D;l of Cortaliod Favoot and Slloworl.oad:- ptnruan( sato Z4. Van G,,SUA"or Z Soct;on 1 11. / c,c[w o• 0 ✓ �^ ,�.� Oato !`t S.�GGonvac+or(Co.(lama)wGa^onlC.o^ a 0 • r,.w.1 I -.-....r ..�1 Trane Cas Furnace • TUC I00C948B3 �_ 902: in accic 4.2 100.0 � c nnn_ TUC 060C936A 90X 60,000 48,000 Cooling Equip- CECCarttflad Comps ssor Untl Adua(' Duct or Type (air oond, ManuL flake & EtWiincy Typo and Typo Lnd R -Value heat um etc (loch( Number SEER) Location ._TRANE- 13 Hutt Compressor eP�4Rr,�nnA - in attic 4.2 1PP016C 1 ()()A Tho binding dosign haat loss and design heat gun Tato have boon 6atorminod using a mothod spo�od in Scctbn l SON tho EnorMoongy St"ards. zod,s two of tho eritoria used for cqupnonl sizing and soloct;orL SrpnatvrtS aoror0 "cf Oatc tN/.CSJ.sono-aclor(co.t�lrmc)orGcnorzlConra WATER KEATING SYSTEMS • EftergYt EjCtefnal WaterKeat(ng CECCatttf'led 4 Rated' Tank trtpui.(M Capactty Factor ort Reoott.ry Standby Tank Insuf(ion SystomtType fTfnexeld Qas_ etc( MartuLf4ake (lode! Number or 8tuh) (gallons) Ettadaney Loss (y) R Yatua Gas -40 gal_ _5[Nc 35_000 — ScandaM PRV 40 NOCTO52 40 .62 1. Foedc"audaa a(or.p<(ratcdinptrtS7S000(iayhr)..iKtltct.a(.t.Lica:ndh.atpumpwat.Ch.alora,talEncrpyfaC:or. For carpo pa c atot.p. Kat.r h..t.ea (rated tnpu(s7S-000 Ott.A.11• rat hated G`wc n000wcy Et%oency and St>%dbfLott. Forza s to nt.[ a eotr c o < a Ka tee h e ctecs. Ct (Ratod lnp[r, and t%oo.ccr E(rooc-cy. F-oC(nctaa4aoovr ctectrtcw<t.r(rutda-ra(fiatC'QIK+u(. FAUCCTS 6[ SHOWER HCAOS All (aucatr 2nd showorhoadt tnrtatlod ala Gttod to [Ito comrntstori s D;l of Cortaliod Favoot and Slloworl.oad:- ptnruan( sato Z4. Van G,,SUA"or Z Soct;on 1 11. / c,c[w o• 0 ✓ �^ ,�.� Oato !`t S.�GGonvac+or(Co.(lama)wGa^onlC.o^ a 0 • r,.w.1 I -.-....r ..�1 Aug 18 05 08:55a LOERKE INSULATION CO.,INC •5306918560 ; P.3 LOEPWE IMMLA-ROM CO., INC. INGULATm CERTIFICATE r � � DESCRIPTM OF WSTALLA710M i. ROOF Mab" erased Name TftOCr m Nom) Thea Red a (R Val) 2. MUNG w or Type 8mmbw_ Brw d Now Johns Mmmle 7htrknm ' l X�N, .2 S N o Them1W ReMstwo (R VaEua) -;�-3 0 Lae FM Type Fla Brod Nares Jobrw MemMo Cmtmt rte min. i adw va&Wft aq. A-4 5 1b. Mkm m Thldmess L Z - --4G k.:h. LftnhcwWs kmbftd v*ht por square trot to adim TheroW RoshMmm (R Value) -xZ() 3. EXTERIOR WALL Thld�ss futdlesl 3.5 4. RAISED FLOOR dial ebmkw Sam Thick= (Irldles) 5. SLAB FLOORVPWAETER • MBIA Thk*rd ss PerinWar fasuiagt Depth (Mdw 6. FOUNDATION WALL mato ffi mss [mdm DECLARATION Re�a)•ss� oa tha oeoe CA-0+4SM60 S dbti c.J� • le • 05 15—m . Dab L', . I"'f_ Brand Name Johnin Momft TbanW R (RVat L "z lkw d Nsma Jgbw AlmdRs Ti amd Resistama (R -Value) Bra nd Nerm Ther nd Res[stam (R Nage) Brand Nfea 110mal Reslsbam (R Viae) ;l�;:. r rf, i � �CSil'.=7= �•:IA[S�.�H' l�lrl�\ =•il 1 �j •a cTl 9` XA. r ech May 4, 2005 Bill Webb Dear Bill: VerTech Structural Engineering 383 RIO UNDO AVE x'200, CHIC O, CA, 95926 PH. (530) E3994371 6 FAX (530) 899-1102 It is OK to put a 16" electrical panel in the #6 shear wall at grid 4. Strap top and bottom of the opening per attached detail. 0 c? j ate-. iyo. S 4732 �< y Exp 0130106 CAS.\F���ti X74 0 PROVIDE SHEAR WALL NAILING ABOVE AND BELOW OPENINGS DOUBLE TOP PLATE HEADER\ KING UDS MAY SOLID BLOCK TYP! WIDTH TRIMMERS # MAY VARY CS16 STRAP X (10'-0" + WINDOW WIDTH) LONG WITH 10d NAILS AT 2 1/16- O.C. CENTERED ON WINDOW. WRAP AT CORNERS WHERE OCCURS.--, �I„ o�.,'�' ---n III 11 11 II 1111� OPENING STRAPPING DETAIL CK NO SCALE W452 NOTES { ' RESIDENTIAL " PE MIT NO 039-460-066 04-0940 WEBB, BILL = R G TRACY RANCID RD; DURHAM y l Cont: OWNER NSF; DECK, COV PORCH GAR IL OFFICE COPY k Address << GAS Date v Meter B ELECTRIC Date , Meter By t SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED (Date) Signature /� J=OK 0 = Not OK = Not Applicable . = Not Ready Date U 7. OK !1 RESIDENTIAL (Single & Duplex) t #'s Date FRA (Continued) Flood -Slope a -Post Caps -Anchors -Connectors Main; Soils-Elec. Grnd.-/ /" FA. Depth Cl' ist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. Garage; Soils-Steel-Elec. Gr . // V /" Ftg. Depth 9 pl Ties or Type A Flue -Fireplace Throat Clearance Porches & Decks; Soils -Steel-/ /" Ftg. Depth Access; Size & Romex Protection -Draft Stop -Ins. Baffles yells, Main; Steel-Blockouts-Wrapped . Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions walls, Garage; Steel- Bloc kouts-Wrapped 52. Gar a Fire Protection Framing -RC Channel Downs and Special Anchors 53. ope Line Firewall & Openings Steel -Wrapped 4. ors One 3' Check Garage 3rd Story, 2 Exits -Fireplace Ftq.-Steel 5@r S rs;Xidth-Headroom-Rise-Run-Landinq-Fire Protection 9: D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 16. Insulation Date WO Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water tr.; Vent -Access -Combustion Air Baffle 1 §meV ACer Pipe; Test & Anchor -Nail Protection W.V.; Test Fittings & Anchor -Nail Protection . Shower Pan; Test, First Floor -Tub Access 21. Te5Kb & Shower, Second Floor -Tub Access as Pipe; Sixe & Anchors 23. Fire Sprinkler; Test Date Card B-1 Date Card B-1 Date Card B -_t Date Card B-1 Date ELEC CAL (Permit) OK except #'s 2 re &XaEnsformer Clearance -Ins. Protection 2 lec ceptacles Spacina-Lights & Switches at Doors 26 xes & No. of Conductors Stapled , e Installed Close to Edge of Studs & C.J. E p round made up w/Mech Fasteners -Bond Gas & Water liance Circuits in Kitchen & Conductor Size GFI feed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al Ran Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al 1 lated Neutral ❑ Yes ❑ No Ue'Sqjrvice-Riser Conductors & Ground Main Disconnect 33. Zq 0' Clearances Panels-Motors-Mech. Equip. othes Closet Light -Shower Light -Spa Light Smoke Detector Date Card B-1 Date Card B-1 Date Card Date Card B-1 Date MEC N AL (Permit) OK except #'s . A . D cts Insulation & Support Ve F ; Exhaust above insulation Date -)L3. ensate Drain & Overflow, Size & Grade Dat - 39 rnace-Vent Access -Comb. Ait-Return Air Vent 115 Outlet Date Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRA G (Permit) OK except #'s 4 S .OK Proper Materials & Anchors 42. W Is Studs -Nailing Spacing & Braces -Plates -Sound arigo Walls over Girders & Floor Nailing Dr top in Walls (rat proof) 4 e Stops, Furred Ceilings -Stairs -Chasers -Tubs �AjirlHeaders & Beams -Size & Bearing 56!Plyood on Roof Overhang -Attic Vents -Rafter Outriggers 57. dina-Nailina Veneer &-j.fo Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59 Glazing Area -Glass Protection -Skylights -Plastic X60. Shear Walls; Nailing -Bolts 61. Interior/Exterior Wall Panels ulation-Walls-Ceilings -@3. Infiltration- - indows Date -)L3. Card B- Date Card B-1 Dat - Card B- Date Card B-1 Date FINAL ) OK except #'s Steos.Door & Sideliaht Protection- Land inas urna emits -clearance -Comb, Air-Connec`.or- In rte; Abgve Floor-Ducts-Mech. Protection 68!G. . Bath Fixtures & Tub Access -Spa c. Trim & Subpanel, Breaker Sizes & Labels. r .jStair Rails Wood Panel, Int. & Clearance 74r.-Siewloutlets & Receptacles at Kit. Counter 7 arag2Fire Door; Swing -Landing -Closure 76. A . Duct in Garaae-Damper iirage; Above Floor-Mech. Protection 7,9! lec. & Mech. Equip. Listed for Location ceptacles in Garage (F.F.I.)-Romex Protection I la ' n -Foam -Looked in Attic rd Rails & Deck Construction -Post Caps 8 Fdn. V2ents & Crawl Hole Door Drainage & Wood -Earth C)a.france Looked underf.lcor ❑ Yes i 8.3f Followinalnstld./Drive UXes O No/Walks ❑Ms- O No;Planters ❑.Ws O No 84. SUxto n -Finish A. nit Disconnect, Electrical -Plumbing en Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87 , Disconnect, Electrical, Plumbing aVtx1eK6`r Elec. Trim, G.F.I. Receptacle -Underground 89'Vero6tion Throughout House 941-Col;e6tions from Previous Inspections 9 as st-Meters Tagged, Gas -Electric 9 r & Sewer Connected -C/O to Grade -HD Approval 9 n y Compliance Certificate -Other Certificates 9 ddress Posted 96. Fire Sprinkl Date _ Card B 1 Date Card B-1 Data Card B-1 iN Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: v=OK 0 = Not OK . = NotReadyable 1. MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except N's 3. 1'. Zoning Requirements -Setbacks -Easements Wood Awn.; Posts- Beams- Rftrs-Connectors„ Shthg-Frg-Bracing 2. Soils; Special MH Support Sketch 6. 3. Sewer; Location -Test -Fall -C/0 -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main Conduit 9. Health Department Approval Date 10. Card B-1 Date Card B-1 Date 11. Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Enclosure; Fencing -Alarms 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line Card B-1 Date Card B-1 3. Gas; MH Test -Demand -Valve -Connector Card B-1 = Date ' - Card B-1 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Date Card B-1 Date Card B-1 Date . Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2: Footing's; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors„ Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses, 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI f '6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test, 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 = Date ' - Card B-1 VerticalTechnology Engineering 383 Rio Lindo Ave Suite 200, Chico, CA 95926 Ph. (530) 899-8716 Fax (530) 899-1102 Email vertech@sbcglobal.net Structural Calculations Client: Bill Webb Project: Hubbard Residence Location: Butte County, CA ®�-o 4:� BUTTE COUNTY BUILDING DiVISI® APPROVED s7/26/vs- Attention: /ate/os Attention: This engineer is not responsible for one inspection to assure compliance with the standards, sizes, materials, or workmanship specified -herein. This engineer is not responsible for any structural element or system not specifically noted in this set of specifications unless authorized in writing by this engineer. Workmanship is to be of the highest quality and in all cases follow accepted construction practice, the latest edition of the Uniform Building Code, and local building department standards. PROJECT ENGINEER DESIGN OF VERTECH ENGINEERING PAGE DATE -7"YP �-144�E- rtn%j o i ENGINEER DESIGN OF V ER 1 EGH CNUlNttFilNU DATE , (fl) ZX12 P�;ajml) �al 0 PROJECT ENGINEER DESIGN OF VERTECH ENGINEERING CA- A, Kit - PAGE DATE May 4, 2005 Bill Webb Dear Bill: VerTech Structural Engineering 3B3 Rio UNDO AVE #200, CHICO, CA, 95926 PH. (530) B99 -B716 FAX (530) B99-1 102 It is OK to put a 16" electrical panel in the #6 shear wall at grid 4. Strap top and bottom of the opening per attached detail. Sincerely, Mike Hubley S.E. Beam Sizer Design Program VerTech Engineering Project: Hubbard Date: 5/4/2005 Location: Rafter ❑ valley Beam Slope of roof 7 :12 Select Beam Width 1.5 in Dead Load 11 psf El Round Member Live Load 16 psf Dimensional ❑ Horiz. Member TULL Defl. Criteria (Ln 240 360 Fb' 1232 psi Length of Beam 14.5 ft Fv' 119 psi Width tributary to beam: 2 ft Unbraced Length 0.5 ft Height Required 8.1 in Co 1.25 CF 1.10 A Req'd 5 inA2 CM 1.00 Cv 1.00 S Req'd 15 in^3 Ct 1.00 Cfu 1.00 1 Req'd 66 in^4 Cf 1.00 Cr 1.00 Controlling Design Deflection CH 1.00 Cc 1.00 CL 1.00 Fbe= 15780 le= 1.0 RB= 6.7 Fb*= 1238 Total Uniform Load 57.469 plf Mmax 1510 ft -Ib Vmax 417 Ib ❑ Shear at d from face? EI Req'd 106 *10^6 #-in^2 Beam Sizer Design Program VerTech Engineering Project: Hubbard Date: 5/4/2005 Location: e Rafter El Valley Beam Slope of roof 7 :12 Select Beam Width 3 in Dead Load 11 psf ❑ Round Member Live Load 16 psf DF -L #2 Dimensional ❑ Horiz. Member TULL Defl. Criteria (U) 240 360 Fb' 1236 psi Length of Beam 14.5 ft Fv' 119 psi Width tributary to beam: 5 ft Unbraced Length 0.5 ft Height Required 8.7 in CD 1.25 CF 1.10 A Req'd 13 in^2 CM 1.00 Cv 1.00 S Req'd 37 in^3 Ct 1.00 Cfu 1.00 1 Req'd 165 in^4 Cf 1.00 Cr 1.00 Controlling Design Deflection CH 1.00 Cc 1.00 CL 1.00 Fbe= 58597 le= 1.0 RB= 3.5 Fb*= 1238 Total Uniform Load 143.674 plf Mmax 3776 ft -Ib Vmax 1042 Ib ❑ Shear at d from face? EI Req'd 264 *10^6 #-in^2 Beam Sizer Design Program VerTech Engineering Project: Hubbard Date: 5/4/2005 Location: Compressed ridge transition point Slope of roof Dead Load Live Load TULL Defl. Criteria (L) Length of Beam Width tributary to beam: Unbraced Length CD 1.25 CF CM 1.00 CV Ct 1.00 Cfu Cf 1.00 Cr CH 1.00 Cc CL 1.00 Fbe= 1820317 RB= 0.6 Total Uniform Load Mmax Vmax EI Req'd ❑ Valley Beam 0 :12 Select Beam Width 11.25 in 357 sf— ❑ Roun ember 0 sf P DF -L #1 Dimensional � ❑D Horiz. Member 240 360 Fb' 1875 psi 9 ft Fv' 119 psi 1 f 0.5 ft Height Required 4.2 in 1.50 A Req'd 2— 0 in^2 1.00 S Req'd 23 in^3 1.00 1 Req'd 69 in^4 1.00 Controlling Design Deflection 1.00 le= 1.0 Fb*= 1875 357.000 plf 3615 ft -lb 1607 Ib ❑ Shear at d from face? 117 *10^6 #-in^2 Beam Design Program VerTech Engineering Project: Hubbard Date: 5/4/05 Location: Ridge XP 8 ft Beam E 2125000 psi P 356 in^4 Seg Loc Stp 1 ft Wt 0.5 in Deflection Wu Lmaln T Lcant 11 R1 �r- R2 LMAIN 16 ft ❑ Apply Special Seismic Load Cases? DL RLL Wu (psf) 0 0 Wt (psf) 0 0 P (lb) 1042 0 at L( 9 ft Section Loc 8 ft Beam E 2125000 psi Beam 1 356 in^4 Seg Loc Stp 1 ft Size IT Step 0.5 in Deflection Live Load Total Load Limit (U ) 360 240 Unbr. Len 0.25 ft Beam Width 3 in Beam Height 11.25 in DF -L #1 Dimensional CD 1.25 CM 1.00 Ct 1.00 CL 1.00 CF- 1.10 CV 1.00 Cfu 1.00 Ci 1.00 Cr 1.00 Cc 1.00 Cf 1.00 CH 1.00 LCANTILEVER 0 ft ❑ Graph Values? FZI Beam Shear at d from face? FLL SL EQ WL 0 0 0 0 0 0 0 0 0 0 0 0 Active Section Location LL DO (in) 0.00 Envelope Max Min M (ft-lbf) 3647 3282 V (lbf) 456 410 DO (in) -0.18 -0.20 R1 (lbf) 456 410 R2 (lbf) 586 528 Cant' Defl (in) 0.00 0.00 LL DO (in) 0.00 Envelope Notes: None Fb Fv 26 psi Fv' 119 psi LL DO 0.00 in Allowable 0.53 in Max M (ft-lbf) 4103 V (lbf) 456 DO (in) 0.00 LL Defl (in) 0.00 Notes: None Fb Fv 26 psi Fv' 119 psi LL DO 0.00 in Allowable 0.53 in 778 psi Fb' 1374 psi TL DO 0.20 in Allowable 0.80 in Min 0 -586 -0.20 0.00 ❑ Include Self Weight? Trib Width 0 ft 0 ft Check Beam Size Beam Beam Design Program VerTech Engineering Project: Hubbard Date: 5/4/05 Location: Ridge XP 7 ft Beam E 2125000 psi P 178 in^4 Seg Loc Stp 1 ft i W[ y� -V -4- Wu Lmaln �C Lc ant Rl R2 LMAIN 14 ft ❑ Apply Special Seismic Load Cases? DL RLL Wu (psf) 0 0 Wt (psf) 0 0 P (lb) 1042 0 at Xp= 2.5 ft Section Loc 7 ft Beam E 2125000 psi Beam 1 178 in^4 Seg Loc Stp 1 ft Size IT Step 0.5 in Deflection Live Load Total Load Limit (U) 360 240 Unbr. Len 0.25 ft Beam Width 1.5 in Beam Height 11.25 in DF -L #1 Dimensional CD 1.25 CM 1.00 Ct 1.00 CL 1.00 CF 1.00 Cv 1.00 Cfu 1.00 Ci 1.00 Cr 1.00 Cc 1.00 Cf 1.00 CH 1.00 LCANTILEVER Max 0 ft ❑ Graph Values? 0 Beam Shear at d from face? FLL SL EQ WL 0 0 0 0 0 0 0 0 0 0 0 0 Active Section Location LL Defl (in) 0.00 Envelope Max Min M (ft-lbf) 1303 1172 V (lbf) -167 -186 Defl (in) -0.13 -0.14 R1 (Ibf) 856 770 R2 (lbf) 186 167 Cant' Defl (in) 0.00 0.00 LL Defl (in) 0.00 Envelope Notes: None Fb Fv 76 psi Fv' 119 psi LL Defl 0.00 in Allowable 0.47 in Max Min M (ft-lbf) 2047 0 V (lbf) 856 -186 Defl (in) 0.00 -0.14 LL Defl (in) 0.00 0.00 Notes: None Fb Fv 76 psi Fv' 119 psi LL Defl 0.00 in Allowable 0.47 in 776 psi Fb' 1247 psi TL Defl 0.14 in Allowable 0.70 in ❑ Include Self Weight? Trib Width 0 ft 0 ft Check Beam Size Beam i ' SITE PLAN REVIEW APPLICATION Date:G O `l AN QJ _0(a tP Permit Number (if applicable) 7 —a U APPLICANT INFORMATION Parcel Size: 0 acIv- Owners Name: tw l� r Owners Address: Telephone No.: Situs Address: Proposed Use: Residential New Single Family Residential ❑ Single Family Addition ❑ Single Family Remodel ❑ Mobile Home Residential Accessory Alt, C�t Ct SL f ��Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other ❑ Septic ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necessary): ❑ Commercial•Remodel ❑ Industrial Remodel ❑ Well DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) IN Approved ❑ Conditionally Approved ❑ Resolve Problems Prior to Approval IN Site Pla Stamped Approved By Date o" Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: ❑ Snow Load Area: ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) a Expansive Soils (Test for expansive soils and if verified proper foundation design required) SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: X • Flood Panel No.: (1160`7CO596C, Index Date: oe .❑ Sacramento River Reclamation District (Approval must be obtained from the Calif inia Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance -------------------------------------------------------------------------------------------- ❑ Detached Building Use Form ❑ Encroachment -Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Zoning Code Streets & Highways Fire Prevention Subdivision Map Fronto r Side Side Street Rear Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 7 Applicable Development Fees: Standard Fees Amount Formula ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Impact ❑ Other ------------------------------------------------------------------------------------------------------------------------- Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By ❑ Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation:❑ No ❑ Yes Comments: ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 Subdivision Map/Parcel Map: —7 Map Date of Recording: / -3 % Q l Lot: ❑ Use Permit/Minor Use Permit Permit Number: Book: * 1 A Page: .2- 9 " 32 Date of Approval: Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development.. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for roa Paee 4 of 5 a 0 Summary of Specific Requirements: This information provided in this summary is based on the application information and on the best available data at the time of review. CALArrys\Building Permit Site Plan Reviewl.doc Page 5 of 5 AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 205—X005237 Recorded Official Records County Of sME CANDAiF- J. GRUBBS Recorder ROSEMARY DICKSON Assistant 02:32PM 27 -Jan -2005 I REC FEE 7.00 1 COPIES 2.00 I I I I I 1 Kathy 1 Page 1 of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: 407- 2S AS SlbwQ oN � TA -PFT «YL.1ntfv� �Vli4P � ` o 2t-tRav� Li�D 2'1 W Wi Chi MA -P W hS la-eco"e`sJ OF T> 6o oAj r 1 of= B v-, 7-E- ) s-Pq-71E- OF CAU ro2nV 1 !q , (A9 J VLA( 31; /11J 3oOK CSZ or mA4>SJ A::r so ):21 i Date_ -OS PRAPE Y OWrrE}3,s: 31�-L l qtr , State of California ) County of 30+ L. ) —211 _ Z6OS before me, personall;appeared_ ' // � personally known to me (or proved,, . me on the oasis of satisfactory evidence) to be the person(s) whose nae(s) is/are subscribed to the within instrument and acknowledged to me that Qshe/they executed the same in ;er/their authorized capacity(ies), and that bx i her/their signature(s) on the instrument, the person(s) or the entity upon behalf auof thorized the person(s) acted, execu ed the instrument. WITNESS my hand and official seal. Signature 'Seal:LQAMVQW"-Ejq*w AMOER tib TAMAR,w ,r� /� � �N 14A7A1e A.P. # V3ff — ij( 0— 066 �C ft* fNO MoN 4, 20089 A W I LLDAN Serving Public Agencies October 20, 2004 Scott Rutherford Butte County Building Department 7 County Center Drive Oroville, CA 95965 (530) 538-7169 (530) 538-2140 FAX SUBJECT: COUNTY OF BUTTE PLAN REVIEW APPROVAL 117 C Street Marysville, California 95901 530/749.2373 fax 530/749.2199 www.willdan.com Willdan Project No: 14359-1048 Jurisdiction Job No: 04-0940 Assessor's Parcel No: 039-460-066 Applicant: Bill Webb Description: New Single -Family Dwelling Dear Mr. Rutherford: Willdan has completed a plan review of submitted plans and documents for the above referenced project and recommends your approval with the conditions noted on the 2nd page of this letter. The plans and documents provided for this review that have been found in compliance with the applicable codes are: 1. Plans: Two (2) copies C1 through A3 (5 sheets) dated 3/02/04 by Scott Jackson, two (2) copies 51.0 through 53.0 (4 sheets) dated 1/03/04 by Michael Hubley, and two (2) copies SDI (I sheet) dated 12/17/04 by Michael Hubley 2. Structural Calculations: Two (2) copies dated 2/24/04 by Michael Hubley of Vertical Technology Engineering 3. Energy Calculations: Two (2) copies dated 2/27/04 by Scott Jackson of Evergreen Development The plans have been stamped with the Willdan approval stamp and dated the date of this letter. According to our previous letters relating to this project, the superseded plans and documents will be discarded within 10 days unless we receive other instructions. On the pages to follow is the identification of the codes and standards applicable to the project, a code analysis, conditions -of -approval and identification of any deferred submittals. APPLICABLE CODES Unless noted otherwise, all comments are based on requirements of the 2001 California Building Standards Code found in the California Code of Regulations, Title 24: • Part 2, known as the California Building Code and abbreviated herein as "CBC". • Part 3, known as the California Electrical Code and abbreviated herein as "CEC". • Part 4, known as the California Mechanical Code and abbreviated herein as "CMC". • Part 5, known as the California Plumbing Code and abbreviated herein as "CPC". 117 C Street W I LLDAN Marysville, California 95901 Serving Public Agencies 530/749.2373 fax 530/749.2199 www.willdan.com • Part 6, known as the California Energy.Code, and Energy Commission Standards, and abbreviated herein as "CECS". CODE ANALYSIS Our plan review revealed the following information regarding the occupancy designation, type of construction, and other pertinent features. I Type of T e yp of 1" Floor 2ndFloor Sprinklers Stories Total, Sq Ft Occu anc Constr;'uction. S Ft h��7777777 -- R-3 V -N ` No 2 2884 766 3650. _ U-1 V -N No 1 1071 NA 1071 . Covered V -N No 1 948 NA 948 Porch Open Porch V -N No 2 NA. 453 453 This information is consistent with that shown on the plans. CONDITIONS OF APPROVAL i 1. Approval is contingent upon the review, requirements and approval of other departments and/or agencies that have jurisdiction over this project. I . 2. Revisions and/or notes as red' -lined on the plans. DEFERREDSUBMITTALS; Our plan review reveals no deferred submittals noted at this time. SPECIAL INSPECTION NEEDS Our plan, review` reveals no special inspection needs pursuant to CBC 1701. i Sincerely, Isaac Kuster Gordon Wright, P. E. Plans Examiner Plan Check Engineer f CC: Alice Mefford, amefford(a,buttecounty.net Michael Hubley; S.E.; Veffech Engineering, verteehna sbcglobal.net FAX (530) 899-1102 } Bill Webb, 121 Yellowstone Drive, Chico, CA 95973 Evergreen Development, 2530 Zanella Way, Chico, CA 95928, FAX (530) 894-5051 Page 2 of 2 i County of.Butte 1.4353-I 135