Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
039-460-090
CertainTeed.M _ j � Builders Statement InsulSafe 4 Fiber Glass Blowing Insulation a Homeowner Name / Jobsite Name 9-1;z (0 ke, )&" MAs �. ✓�ltA(�s Installer/Contractor (sign) Company Name Date Builder (sign) Company Name Date Inspected By (sign if required) Date R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG . MINIMUM WEIGHT- POUNDS PER SQ. FT. MINIMUM THICKNESS To obtain a Thermal Resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag should not cover more than: (sq. ft.) Weight per sq. ft. of installed insulation should not be less than: abs.) Should not be less than: an.) 60 36.5 27 0.986 22 49 29.6 34 0.800 181/2 44 26.4 38 0.712 16'/4 38 22.8 44 0.615 143/4 30 18.0 56 0.485 12 26 15.5 65 0.418 10'/2 22 13.1 76 0.353 9 19 11.1 90 0.301 73/4 13 7.7 129 0.209 51/2 11 .6.6 151 0.179 43/4 ' THERMAL PERFORMANCE—ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number'of bags per 1,000 sq. ft of net area for each R -Value listed. I • The maximum net coverage must not exceed that specified for each R -Value. • The installed insulation must be at or above the specified minimum thickness for each R -Value. • Failure to install the required minimum weight per sq. ft of insulation at or above the minimum thickness will result in reduced R -Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. • DANGER: RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. 30-24-233 Builders Statement A Saint-Gobain Company ©2002 CertainTeed Corporation 11/02 R -VALUE THICKNESS AREA (SQ. FT.) . INSULSAFE 4 BAGS USED BATTS/ROLLS (✓) CEILINGS WALLS FLOORS ' THERMAL PERFORMANCE—ATTIC BLOWING APPLICATION • In accordance with the chart above, you must install the minimum number'of bags per 1,000 sq. ft of net area for each R -Value listed. I • The maximum net coverage must not exceed that specified for each R -Value. • The installed insulation must be at or above the specified minimum thickness for each R -Value. • Failure to install the required minimum weight per sq. ft of insulation at or above the minimum thickness will result in reduced R -Value. • This product should not be mixed with other blown insulations or the thermal claims will become invalid. • DANGER: RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OF SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. 30-24-233 Builders Statement A Saint-Gobain Company ©2002 CertainTeed Corporation 11/02 ■ Manufacturer Insulation Fact Sheet CertainTeedCq This is CertainTeed Corporation I nsu Sae 4 Fiber Glass Blowing Insulation CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 THERMAL PERFORMANCE—HORIZONTAL OPEN BLOW 4 The following thermal performances are achieved at weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application: R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG MINIMUM WEIGHT- POUNDS PER SQ. FT. MINIMUM THICKNESS To obtain a Thermal Resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag should not cover more than: (sq. ft.) Weight per sq. ft. of installed insulation should not be less than: (lbs.) Should not be less than: (in.) 60 36.5 27 0.986 22 49 29.6 34 0.800 181/2 44 26.4 38 0.712 163/4 38 22.8 44 0.615 143/4 30 18.0 56 0.485 12 26 15.5 65 0.418 102 22 13.1 76 0.353 9 19 11.1 90 0.301 73/4 13 7.7 129 0.209 5'/2 11 6.6 151 0.179 4 3/4 R -values are determined in accordance with ASTM C 687 and C 518. Complies with ASTM C 764 as Type 1 insulation. THERMAL PERFORMANCE—SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the foll6wing thermal performances are achieved at the thicknesses, weights and coverages specified. R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG MINIMUM WEIGHT- POUNDS PER SQ. FT. MINIMUM THICKNESS To obtain a Thermal Resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag should not cover more than: (sq'ft.) Weight per sq. ft. of installed insulation should not be less than: (lbs.) Should not be less than: (in.) 29 35.8 28 0.967 71/4 22 27.2 37 0.733 51/2 16 19.8 51 q 0.533 4 15 17.9 56 0.484 3s/e 14 17.3 58 0.467 372 READ THIS BEFORE YOU BUY What you should know about R -Values. The chart shows the R -Value of this insulation. R means resistance to heat flow. The higher the R - Value, the greater the insulating power. Compare insulation R -Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the Climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R -Value, it is essential that this insulation be installed properly. 0 • • Jan.12. 2005 10:59AM MEEKS CHI CO� ..••• No•4529 P. 1/1 I.. A J. &V ` F certificate of Conform-,ant,,.*.,,E-_,, Certificate 0 5 2 7 3 5 ' THIS IS TO Ci=FiTIEY that the glued laminated timber products identified with a colle.- ve mark of Engineered Wood Systems (EWS) were manufactured in accordance with the apptica;;i, standards and associated specifications indicated tka-lover. ANSI Standard k190,1-1992, For Wood Products - Structural hued Laminated Timber NER-486 Glued Laminated Timber Combinations And `GAP" Computer Program For Determining Design Stresses ' A 1TC 117-93 - Manufacturing - Standard Specifications For Structural Glued Laminated 1-imber Of Softwood Species ?T IS HtREBY CERTIFIED that the APA. EWS trademarked structural glued laminated tifT-bG.' member, were produced in a manufacturing iacllity subject to regular audits in actor lance with the E,T,ginesred WOOd Systeme-(EWS) Quality Assurance Program. Routine audits include insp ec;;on of the manuiacturing process and evaluation of the in -plant QA program with adequate sarrrr{;ng to vsriiy coniormance to industry standards for lumber grade and giueline bond quality. 1 �e �l ,' t-4ms S�d.,�- I10 -S a✓i /°Ie.fl,'� "'s J�� 51)G W Do Its A SIF—Al y� r � � �ilM<l 3� r i y ,Vj.• 01 ala Y � � by Thomas G, Wllliamsc; l Executive Vice Presiti(,:)t ENG'�✓fE�FJ 1'K70D S`"Si LMS �) 0 ld0lea GMDnrPI.(fn Ot P.�jt .. Y�.,. 70' 1 scwm 19th Srew - (v, E ENGIN@FSHD w�OD.455DCK7�Cjn• d. gar ,rroo • 7=conn.. Wti pBc,,.o7lro T-tophor": 4253) 6;64-e000 • Fer Nvm1w. (253) SGS7?6S PLAN REVISION Owner's Name:��� BP#: 03– l R11 Date: /oa f V 1 Contact Person & Phone Number:I INK�oaW �. Time: /'6-'D T PURPOSE -OF RE -SUBMITTAL OR REVISION ❑ Permit Application Data Sheet Item ❑ �*Engineering 0' *Plan Revision ❑ *Requested by Building Inspector's Correction Notice – Inspector's Name: ❑ Requested by Plan's Examiner – Plan Examiner's Name: ❑ Other: *If revising a plan which has already been issued, submit two (2) drawings reflecting the revision for plan review along with your approved plans. If engineering is involved in this revision, the engineer must put his requirements on these drawings and wet stamp and sign two sets of engineered drawings. Revised drawings must. clearly show changes proposed and locations involved. WHEN APPROVED, PROCESS AS FOLLOWS: ❑ Mail to Owner/Contractor at this address: M- Call and hold for pick-up. ❑ Deliver with next inspection. Minimum revised plan check fee to - be collected at time of submission of revision, plans examiner will determine if additional plan checking fees are needed: Q Minimum $54.99 Receipt #: va�__ — ❑ Fee not required for revisions requested by plans examiner prior to issuance of permit. ❑ Additional Fee Amount: Receipt #: Revised 2/04 r C o ii✓s a (= -sF_ rb R, H --C> 2 Roof Beam( 2001 California Building Code (97 NDS)1 Ver: 6.00.5 By: Gregory A. Peitz, Architect on: 09-17-2004 : 9:17:35 PM Project: MERRITT HOUSE - Location: LIVING ROOM WINDOWS Summary: 3.5 IN x 5.5 IN x 4.3 FT / #2 - Douglas Fir -Larch - Dry Use Section Adequate By: 73.7% Controlling Factor: Area / Depth Required 4.07 In Deflections: Dead Load: DLD= Live Load: LLD= Total Load: TLD= Reactions (Each End): Live Load: LL-Rxn= Dead Load: DL-Rxn= Total Load: TL-Rxn= Bearing Length Required (Beam only, support capacity not checked): BL= Beam Data: Span: L= Maximum Unbraced Span: Lu= Pitch Of Roof: RP= Live Load Deflect. Criteria: U Total Load Deflect. Criteria: U Non -Snow Live Load: Roof Loaded Area: Live Load Method: ti�C/�, RLA= �J ; �e Roof Loadinq:��� �,'�� Method = Roof Live Load -Side One: �Ry LL1= Roof Dead Load -Side One: v �� �,� DLI= Tributary Width -Side One: Roof Live Load -Side Two: Moo C 21283 N �. TW1= LL2= Roof Dead Load -Side Two: DL2= Tributary Width -Side Two: N T TW2= Roof Duration Factor: RE�S.,�_ � Beam Self Weight: �F Cd= BSW= �� Slope/Pitch Adjusted Lengths and Loads: \\ CiAy� Adjusted Beam Length: Ladi= Beam Uniform Live Load: wL= Beam Uniform Dead Load: wDadj= —WT= Total Uniform Load: Properties For: #2- Douglas Fir -Larch Bending Stress: Fb= Shear Stress: Fv= Modulus of Elasticity: E= Stress Perpendicular to Grain: FcLperp= Adjusted Properties Fb' (Tension): Fb'= Adjustment Factors: Cd=1.25 Cf --1.30 Fv': FV= Adjustment Factors: Cd=1.25 Design Requirements: Controlling Moment: 2.15 ft from left support Critical moment created by combining all dead and live loads. Controlling Shear: At a distanced from support. Critical shear created by combining all dead and live loads. Comparisons With Required Sections: Section Modulus (Moment): Sreq= S= Areq= A= Ireq= COUNTY 1= 0.02 IN 0.03 IN = U1750 0.05 IN = U1021 640 LB 457 LB 1097 LB 0.50 IN 4.3 FT 0.0 FT 6 :12 240 180 80.0 SF One 16.0 PSF 10.0 PSF 15.0 FT 16.0 PSF 10.0 PSF 3.6 FT 1.25 5 PLF 4.3 FT 298 PLF 213 PLF 510 PLF 900 PSI 95 PSI 1600000 PSI 625 PSI 1463 PSI 119 PSI M= 1179 FT -LB V= 878 LB Area (Shear): Moment of Inertia (Deflection): inme opop -be HW R BUTTE BUILDING DIVISION APPROVE' �✓W iS� �'► +0 BP 9.68 IN3 17.65 IN3 11.09 IN2 19.25 IN2 8.56 IN4 48.53 IN4 034 4/0 4to/ Ceqale r rev Roof Beam[ 2001 California Building Code (97 NDS) ) Ver: 6.00.5 By: Gregory A. Peitz, Architect on: 09-17-2004: 5:59:07 PM Project: MERRITT HOUSE -Location: MASTER BEDROOM PATIO DOORS _-, 4t -Sc;, Fo i f� Summary: 6926 3.5 IN x 11.25 IN x 9.5 FT / #2 - Douglas Fir -Larch - Dry Use /V00 K Section Adequate By: 9.9% Controlling Factor: Section Modulus / Depth Required 10.73 In Deflections: 67.16 Dead Load: DLD= Live Load: LLD= Total Load: TLD= Reactions (Each End): A= Live Load: LL-Rxn= Dead Load: DL-Rxn= Total Load: TL-Rxn= Bearing Length Required (Beam only, support capacity not checked): BL= Beam Data: Span: L= Maximum Unbraced Span: Lu= Pitch Of Roof: RP= Live Load Deflect. Criteria: L/ Total Load Deflect. Criteria: L/ Non -Snow Live Load: Roof Loaded Area: RLA= Live Load Method: Method = Roof Loading: Roof Live Load -Side One: LL1= Roof Dead Load -Side One: DL1= Tributary Width -Side One: TW1= Roof Live Load -Side Two: LL2= Roof Dead Load -Side Two: DL2= Tributary Width -Side Two: TW2= Roof Duration Factor: Cd= Beam Self Weight: BSW= Slope/Pitch Adjusted Lengths and Loads: Adjusted Beam Length: Ladi= Beam Uniform Live Load: wL= Beam Uniform Dead Load: wD_adi= Total Uniform Load: wT= Properties For: #2- Douglas Fir -Larch Bending Stress: Fb= Shear Stress: Fv= Modulus of Elasticity: E= Stress Perpendicular to Grain: Fpm Adjusted Properties -perp= Fb' (Tension): Fb'= Adjustment Factors: Cd=1.25 Cf --1.10 Fv': Adjustment Factors: Cd=1.25 Design Requirements: Controlling Moment: 4.75 ft from left support Critical moment created by combining all dead and live loads. Controlling Shear: At a distanced from support. Critical shear created by combining all dead and live loads. Comparisons With Required Sections: Section Modulus (Moment): Area (Shear): Moment of Inertia (Deflection): Fv'= W //tndw 1 0.08 IN 0.09 IN = U1230 0.17 IN = U673 1596 LB 1320 LB 2916 LB 1.33 IN 9.5 FT 0.0 FT 6 :12 240 180 228.0 SF One 14.0 PSF 10.0 PSF 22.0 FT 14.0 PSF 10.0 PSF 2.0 FT 1.25 10 PLF 9.5 FT 336 PLF 278 PLF 614 PLF 900 PSI 95 PSI 1600000 PSI 625 PSI 1238 PSI 119 PSI M= 6926 FT -LB V= 2391 LB Sreq= 67.16 IN3 S= 73.83 IN3 Areq= 30.20 IN2 A= 39.38 IN2 Ireq= 111.01 IN4 1= 415.28 IN4 7,* Roof Beam[ 2001 California Building Code (97 NDS) 1 Ver: 6.00.5 By: Greonry A Pait7 Architect on: 09-17-2004: 9:1 :06 PM Project: MERRITT HOUSE- Location FI:Z&147, P000p�. ;E^/ TK�, 1395 Summary: Sreq= ( 2 ) 3.5 IN x 5.5 IN x 6.3 FT / #2 - Douglas Fir -Larch - Dry Use IN3 Section Adequate By: 68.4% Controlling Factor: Section Modulus / Depth Required 4.24 In Deflections: IN3 Dead Load: DLD= Live Load: LLD= Total Load: TLD= Reactions (Each End): 27.15 Live Load: LL-Rxn= Dead Load: DL-Rxn= Total Load: TL-Rxn= Bearing Length Required (Beam only, support capacity not checked): BL= Beam Data: Span: L= Maximum Unbraced Span: Lu= Pitch Of Roof: RP= Live Load Deflect. Criteria: L/ Total Load Deflect. Criteria: L/ Non -Snow Live Load: Roof Loaded Area: RLA= Live Load Method: Method = Roof Loading: Roof Live Load -Side One: LL1= Roof Dead Load -Side One: DL1= Tributary Width -Side One: TWI= Roof Live Load -Side Two: LL2= Roof Dead Load=Side.Two: DL2= Tributary Width -Side Two: T/2= Roof Duration Factor: Cd= Beam Self Weight: BSW= Slope/Pitch Adjusted Lengths and Loads: Adjusted Beam Length: Ladi= Beam Uniform Live Load. wL= Beam Uniform Dead Load: wD_adi= Total Uniform Load: wT= Properties For: #2- Douglas Fir -Larch Bending Stress: Fb= Shear Stress: Fv= Modulus of Elasticity: E_ Stress Perpendicular to Grain: Fc Adjusted Properties -perp= Fb' (Tension): Fb'= Adjustment Factors: Cd=1.25 Cf=1.30 Fv': Adjustment Factors: Cd=1.25 Design Requirements: Controlling Moment: 3.15 ft from left support Critical moment created by combining all dead and live loads. Controlling Shear: At a distanced from support. Critical shear created by combining all dead and live loads. Comparisons With Required Sections: Section Modulus (Moment): Area (Shear): Moment of Inertia (Deflection): FV= -yj di coin ft P?-, 0.05 IN 0.07 IN = U1113 0.12 IN = U643 937 LB 685 LB 1622 LB 0.37 IN 6.3 FT 0.0 FT 6 :12 240 180 117.2 SF One 16.0 PSF 10.0 PSF 15.0 FT 16.0 PSF 10.0 PSF 3.6 FT 1.25 9 PLF 6.3 FT 298 PLF 217 PLF 515 PLF 900 PSI 95 PSI 1600000 PSI 625 PSI 1463 PSl 119 PSI M= 2555 FT -L6 V= 1395 LB Sreq= 20.96 IN3 S= 35.29 IN3 Areq= 17.62 IN2 A= 38.50 IN2 Ireq= 27.15 IN4 1= 97.05 IN4 - O DEVELOPMENT SERVICES - COUNTY OF BUTTE DEPARTMENT F BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-753-11 38-753 6_' 1 EERMIIT No. (Rev. 12/96) APPLICATION AND PERMIT `�`-�' ASSESSO�ilDE4 NMj9E�+ 90 y (+ U U ZONING BUILDING PERMIT OWNERU STAN MERRITT 343-2002 TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS 5602 MACANARLAN LANE DURHAM CA 95938 910 U 16,380.00 DDMRAKEVIN EPIERCE 895-1113 TELEPHONE745 C 9 85.00 CONTRACTORS MAIUNG ADDRESS PO BOX 7468 CHICO CA 95927 CONSTRUCTION LENDER Fireplace A 1500.00 LENDER'S M.UUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER UCENSE NO. Fee $ 20.00 -Filing Permit Fee $ 1017-50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ rrl AR BUILDINGADDRESS 9326 LA ROSE CT DURHAM CA Energy Plan Checking Fee $ 21-00 $ PERMIT FEE $ 1791 _,qS LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 105-.00 Solar or hest um water heater 23.00 Water piping 15.0015.00 Each as water heater or vent 15.0015.00 TYPE OF WORK Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: �j�jvl 2 5 ]A SIG�F PAM1� Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 SPRINKLER 15.00 PERMIT FEE $ 200, 00 ELECTRICAL PERMIT Fling Fee 20.00 800VMain Service 2DDA OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class 'c n Lic. No. J7 1 % OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service zoOA TO I 000 46.00 NEW CONST. ( OWEWNG OCCUP. OR ADONS.. 3.5Qs'148. 51 NEW CONSTMUL�TICOUTLS. LpµRESID. C @7.50 APPARATUS 8 SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FD(TURES 20 p 1.00 BAL @ .SD Ex. Occup. OFlxuTLEEDTSA Aa ) E 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 191.51 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that f I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X K —�� Date a O 3 Signature of Applicant - ❑ Owner -X Contractor ❑ Agen An OSHA permit is required for excavations over 5'0"deep and demolition or constructionn1f of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating 2 119-00 30-00 Cooling Hood 6.50 Ventilation 8.00 PERMIT FEE $ 99.50 Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ corer. TYPE O L FEE $ 2258.88 HAZ. D. F D CDF PAR H SSUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have PERMIT EXPIRES -6 1 the applicable provisions Resolutions to do work been paid. Da 05- afe ReceiptNo. ?CT3776 27 — 773 _ 1 WHITE-D.D.S.-B.D. CANARY -ASSESSOR I K -INSPECTOR OLDENROD-APPLICANT k") L\ Feb 01 02 08:13a COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISIO 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 tRev.12/ga) APPLICATION AND PERMIT r PERMIT .. ASSESSORPARCELNUMSER 39, H6 - /!`// � 20NINCSR _ ' BUILDING PERMIT OWNER Sr,A,V /�9FRa frT -- TELEPHONE 3Y3 2©}02_ SO. FT. OCC. BUILDING VALUATION 3333 P, F7 ------ OWNERS MAILING ADDRESS MAC A/V/AA� _r ` Ld 10 0 A, , 9 / 3 5602 /- - --- 10 U 16 -- '3 BD COMMCTOR'S NAME } yv//\/ P 1 E/m r TELEPHONE �7 /'oJ j l ` o •-- - CO R0TO SR'S MAILING / DRESS j '75172,7 6 -8 C tJ 1 C `, ( `A / i %2 % '71/6-8 il C �Y --- CONSTRUCTION LENDER Fireplace $ 15,00 -LENDER'S MAILING ADDRESS Total Valuation $'L N ARCHITECT ORNGIEER rim LICENSE NO. Filing Fee $ 2 • 0 Permit Fee �1 6 $ 0 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checkin Fee $ _&q0_735 -LTUILDINGAODRE LA ROSC GT Energy Plan Checking Fee $ 23 _ # qt, o V R HAIY1 �I f hr� L -,P, J L1 �-S' I PERMIT FEE $ LOT No. 33 SUBDNL910NS NAME �5y.,_3S 37 6-18-D PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 I �_ USEOFSTRUCTURE I ,US A�- SFX Duplex ❑ Mobilehome ❑ Other SPECIFYEach Solar or heat pump water heater 23.00 Water piping 15.00 15 gas water heater or vent 15.00 / TYPE OF WORK New A Addition ❑ Remodel ❑ Uliliti"es ❑ Installation 13 Other y❑ Describe Work: 3 ak 2 BIGt,�!-% V d,�?, Kato C' Gas piping system 1 - 5 outlets 15.00 I f Buildingsewer 15.00 15 Mobile Home ISI al W1 920.00 SPA INK LE2 1 PERMIT FEE $ 00. ELECTRICAL PERMIT Filing Fee 20.00 aoov oR tess Main Service zooAOR tEss 23.00 23 Cllr . '� OS � 7e i— v (�L� %� •. (/ �"'t 9 •1t n " PEPAIT FEE PAM � �� � y � SIM c SHEMPERM17 arm. AA6VNT RECEM0 : "773 y8not * 3-75- 6'Z% To:E w ngro COmim Main Service II TO IOOOA 46.00 r;L NEW coNOT. u� pWE1LIND OCCUP. 3.501, I49. C OR ADDNS. %r3 6 ACC. BLDS. Fr. I G .7 NtW CO 5 I. MULTI.OUTLET /�1 NON•RES10. QG 7.501 POWER APPAMTUS -'• 'POWER OIIILET 0 - Ex. Occup. ovnzr OR FORURes 20 ® ,.00 6AL ® .50 FIXED APPLNS. OR Ex. Occup. GIlnETD �,o, Ew 5.00 _ Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring23.00 FEE $ 1. MECHANICAL PERMIT Filing Fee 1 20.00 Heating IF 1 30 Cooling S 25- ` QS Hood 6.50 i 6.50 Ventilation PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection Fee S y occ CONST. TMPE TOTXL FEE $ HA2. D. FEES I VO I CDF I P' EL I NO I ISSUE This permit is hereby issued under of the Butte County Code and/or Indicated above for which fees have jEByEXPIRES ON - the applicable pr6visibns Resolutions to do work been -paid. DateReceiptNo.PERMIT ere - WHITE-D.D.S.•B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT f l f� 3 i • 1 � COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION ti 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET St A � Mt AAI rr ASSESSOR PARCEL NUMBER 3q, / 6 F OWNER: �j _ Proposed Building Use: �r 36/1 SXc Counter Technician: C H t Co Date: q " y 3 Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. Of 1.. Plot plans, 3 or 4 sets, signed by the preparer of the plans. V 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. [X,3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. • a ' Vim. Engineered truss details and layouts in duplicate. No faxes! Ca% Energy compliance design and supporting documentation in duplicate. 0HA. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. \\ VIF.. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. 14 Items required+for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required.items are received. Date Received � ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ By ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... ❑ 12. Hazardous Material Form............................................................................... ❑ 13. Other .... a�inn items needed to issue the permit. (May require additional plan review upon receipt of the ffooJlowing items.) 1 y85. yo ees as shown on the attached Schedule of Fees Due Sheet ................................ : ...... ❑ ,5. Statement of Intent for Non -heated and A/C Buildings......................................�.� 6. Sanitation and plot plan approval from the Environmental Health Department in 17. City of Chico Plumbing permit........................................................................ ❑ 18. California Department of Forestry plan approval ❑ paid. Sent by: ...................... ❑ 19. Planning approval for (A) Use: ® i, (B)Parking: (C) Parcel Check: L, �8 ❑. 20.ontact Land Development about ❑ Improvements, ❑ Drainage ............................... �. K1ychment Permit for driveway from the Public Works Dept. (construction approval prior to occupanc re -Inspection for required ................ ❑ 23 Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24 Worker's Compensation Carrier and Policy Number ..............:..... ........................ ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owne �..................... I f Signature authorization................................................................... 2�. e de opy of Agricultural Acknowledgment Statement ................................... actured home utility clearance............................................................... ❑ 29. Existing violations and/or expired permits......................................................... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: When issued Telephone _ and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: ` , Dat //;4//0,3j — a- 1. Index permit application for the above items numbered: ( Plan Check Letter 2. Additional items required a 3 Contractor, designer, owner, was advised of the above data by Vphone, ❑ mail, ❑ counter, by DatM3ft6 Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: —Date: Plans Plans approved by: _ Date:^ —6 Structural reviewed by: Date`:; Structural approved by: Date: Note transfer by: 1 b_q —(�' .�a W �.-117016t6:3 Yellow' Building Division W ` Li •W ��3 /. 1 TO: Building Department FROM: !"Environmental Health SUBJECT: Sanitation Clearance E.H. USE ONLY l o: Ps.o Attachedw � Floor Plan Attached (] i Sana to B.D. �i2 R—nrz M Owner Location AP# Plan Approved for: Sewage Disposal _� Water Supply: Public -i Private Well Clearance for dwelling. Other final for: Final clearance O.K. for: NOTE: Environmental Health Specialist Date 8/96 OWNER COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE St -A 4 CAA) i7 - PROPOSED BUILDING USE BUILDING PERMIT FEES Balance Due ....................... $ Additional Fees Due ................. $ Additional Fees Due ................. $ 6QRevised Plan Checking Fee .............$ SCHOOL DISTRICT FEES u R PIA s» (paid at District Office) (Available after Plan Check) P3.1 SHERIFF FEES (paid at Building Division) Residential ...................... I x $360.00 = $ Units Commercial (sq. ft.) ............... x $0.03 = $ Sq. ft. 4. URBAN AREA FEES (paid at Building Division) Residential ................... —x—=$ # Units Amt. Commercial (sq. ft.) ............ —x—=$- Sq. x=$_Sq. ft. Amt. S. REATIONAL DISTRICT FEES D UR NAM (paid at District Office) (Available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER 1.360 qb A.P. # 3 If" y6 - 01&3� DATE 1A /0— RECEIPT # DT C. 81s,00 At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE /l Q Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). /A Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 6/00) ENCROACHMENT PERMIT County of Butte Department of Public Works 7 Count Center Drive Oroville, CA 95965 Phone (530) 538-7157 Ext. 2016 Fax: (530) 538-4356 Download Forms: www.buttecounty.net/publicworks/forms.html NOTIFY COUNTY 24 HOURS BEFORE WORK IS TO BE DONE Phone (530) 538-7157 Ext. 2016 Permit Number District APPLICATION I / WE, the undersigned, hereby apply to the County of Butte for an encroachment peninit to do the following work under or over the County roads and hi hwas, all in ac ordance with 90-unty ordin es and general laws. All information except signature must be typed or legibly rinted. 1. Applicant's Name: ` 1 Ia. Company Name: 2. Address: V � ,• 3. Phone: •.. , z I _ 1 , ' T 4. Assessor Parcel N er; 090 o'f 5. Locatio f Work tc5be Done Sam i �' X1'1 i 6. Applicant's Signature 4L. 7. Date: %�� / � // .^�� L/ '� L/ CONTRACTOR'S INFORMATION 8. Contractor's Name CdJ it - 9. Address 10. Phone: 11. Fax: 12. Contractor's License Number. 13. Certificate of Insurance: Yes ❑ No: ❑ 14. Contractor's Signature: 14a. Date Signed: 15. Authorized Agent: TYPE OF WORK TO BE DONE 16. Please Check: Curb: ❑ Gutter: ❑ Sidewalk: ❑ 17. Driveway (List Type): s Chi 18.Other: PERMIT GRANTED In compliance with the above request, and subject to all terms, conditions (including those on page 2 of this permit form) and special conditions written below, ermission is hereby granted. 19. Conditions Underground Service Alert .S.A. must be notified two working days prior to any excavation. 800-227-2600 20. 09LA11 work shall conform to accompanying: Detail ❑ Plans ❑ Special Conditions 21. Date Issued f 03 O y 22. Expiration Date: o 23 Surety: Mike Cramp, Director of•Public.Works By: ** Note: If permits are faxed to any number besides (530) 538-4356, they can be delayed up to one vAek. Page 1 of 2 General Conditions — See Page 2 AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 COPY of Document Recorded 04 -May -2004 2004-0026053 Has not been compared with original BUTTE COUNTY RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, -including -bat not -limited to -herbicides; pesticides,"and fertilizers; -and from the ursuif of a tcul"tural o erations P gr.— P including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor.' Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience. or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: L 0� 3 3 as SAOW4 oPI 7 %cdcev-tal`vl /yla�o eni fie d «p�I�hali �-an d Estate s f PA�xg e �- -�� l ed ; ri 4 e c r". e of *A -e- Caumty 0ecol,dev, o4 9u'ffe Couml yj C'cl_r/"oto9/la, o n �u � � rg � 2 oo 2 � &1 b o o k f �, o-¢ m�,oS� a � pa g e(S� 3s3 Date 5S — � 4 q PROPERTY OWNERS: State of California ) County of OUj1 el > On before me, He-G(l Q• A-ct..iLl,l.(1 personally appeared 340J,7/el A-. personally known to me (or proved to on th basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my h nd and offic' .Signatur Seal: HF -IDI R. HUKILL q- COMM. #1411254 m toW.My Notary Publie-Callfomla (n WBUTTE COUNTY A.P. # f) —p '- Q ?0 Comm. Exp. April 15, 2007 Z� - off ZE`o 3 41� 4 • _ j yy1 � `. � �°wr` � t BUTTE. COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM Building) (One form per , � ,�, � •�+' ��..� ." a I f} j"'i � 1 r- .�"' i ( ; `� ` ` ! i �" School District Building Department No. �r t/ , /� 0.39-14W-0.90 170 A.P. Number '_ - Jurisdiction: !� J� lClty��� .County Property Owner i t 1 ` Property LocatioNAddress MOO �04- CL e \ 1t Subdivis ori / .......................t............................. Residential De ��Igpment ,! ...................................... ...•`.. , - Sq. Footage �.: 33 3 3 No'of Living„� !, Mobile Home AdditioNj •Suppgeelemental�to Y (Group R) e Units. Installation a Conversion Permit # *(No foundation inspection)I. ................................................................................................................... CommerciaUlndusbial” - F Sq. Footage New Addition (Including Exterior Building Department t (door dans reweweo by school Uistnct Nersonneq ,r District Identification No. (e, 0`17 3 Dbr ekke-Aly �% / FI e� 7 School District certifies that T� GI3oZ % L�1 I�iC'SE CT (Street Address)'" Thu lel-ern (City) has complied with the requirements.of Resolution No. representing 3333 square feet. School District Representative i Paid by Check # _ �� / Remarks: T e ' u s � Roofed Areas) /0'9-03 Date ,5721 N, melee-177," (Applicant) 34 3-2 6o 'I, (Phone Number) COO 95; 93 S' (State) (Zip Code) t ` 6..? -D .2, by payment of $ 1�13 2926 $ FULL MITIGATION $ s-�-off Date Notice: You may protest the imposition of the fees identified above by submitting•a written protest to the District, in compliance with Government Code Section 66020(x), within 90 days from thl date fees are paid. Failure to submit a timely written,protest will prohibit you from challenging the imposition,of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the,applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm r -.,F4 , , . ,..r, .-1 +" .� �,, j I "I " J;BUTTE COUNTY PARK FACILITII'.FEE PAYMENT CERTIFICATION FORM DURHAM RECREATION AND PARK DISTRICT TAssessor Parcel Number (s): Property Owner (s): ��iC�Clc1Y1 j \Project Location/Address t Subdivison Name lLUULp CA -r► f)0h'dtC_,at*V Assessable Square Footage: 333 13 Type of Residential Development (check one): New'Development Alteration/Addition ❑ Mobile'Home (s) Non -Residential to Residential Comments: lv- 9 -o3 Building Division Representative Date Durham Recreation and Park District (DRPD) certifies that M,r►7H_ 3- 2 -002 - Applicant Name Applicant Phone NuHber cl to 62 M 1 A_na r 1 in A ve., Street Address State m Zip Code has complied with the requirements of the Butte County Board of Supervisors Resolution No. 93 - 114 by payment forsquare feet at $ 1.04 per square foot for a total payment 3:2- •of$3'4wo- . o-Yv 51y 10y '---b6PD Representative Date BANK No.: q0 - X90 L4 PAID BY CASH: RECEIPT No.: Remarks: DISTRIBUTION: WHITE - APPLICANT PINK - DRPD YELLOW - BUTTE CO. BUILDING DIVISION Butte County Deparnnent ofDevelopment Services YVONNE CHRISTOPHER, DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile TO: LP2A FROM: Michael Vieira (530) 538-7159 mvieira(cD-buttecounty.net SUBJECT: Plans Transmittal For Review Per Contract DATE: 7/10/2003 Applicant: Merritt, Stan Project Type: NSF 100% Plan Check Fees $ 661.38 Energy Calc Fees $ 23.00 $ 684.38 Permit No: 03-1199 APN: 39-46-90 70% $ 462.97 $ 16.10 $ 479.07 LP2A Fee- $ 479.07 Copies Attached: Qty Chk - Application Site Plan Review FEMA Elevation Certificate Building Plans Truss Calculations Energy Calculations Structural Calculations Residential Plan Review Guide Residential Construction Requirements Other Other r• s W { AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 63-1111 NSs4.d 2004-0026053 Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 11:10AM 04 -May -2004 REC FEE 7.00 CONFORM 1.00 Travis Page 1 of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary.farm operations. All that real property situate in the County of Butte, State of California, described as follows: L of 3 3 a -s sAowvl on fk-t Ce�`�af1 V1 A/4,0 eniJIed cr DuIr w o► ya n d Estaf e s PAa.s e !ecfl ; e oty-tce e 11 of *A -e- coumty Oecov'de✓, o49uIfe- C.oumfkl, 62alP�o�'�ldiQ. Q 11 ZYu > I .e 46 ?0o2 i -n book 1.<-4, o -f ryir ,oS� Q � Date Is-- 4 — o q PROPERTY OWNERS: Yro,Pg I e /`I. ZLI eIr r,' II State of California ) County of OUT -Fe ) On YY OLU L11 9-bZ) y before me, 06di 9.44Ulc i, ) personally appeared personally known to me (or proved to me on th basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/:�er/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my h nd and offic' Signatur Seal: HEIDI R. HUKILL COMM. 0411254 fn Nota Public-Callfomia In A.P.# O — 4&0-0!O W WMy, BUTTE COUNTY -• Comm. Exp. AO 15, 2007 I�II�I�II��II�II�I�iII��III��IIII Z:a:csoaSoo ---4-11-0WW 333 33B 1 bib-MsR Pbmog is OMO 1 to yt uoo I I aeb^rcasA i Yl02?!3IQ yflm4 m aivs^iT 1 inshICIA 110 t sQaq I P98S-gsM-�A MABI:II rr:r a 4.A ` - SITE PLAN REVIEW APPLICATION Date: 4 -2Li-0 AP# a?R ^ L4 C9 C) Permit Number (if applicable) d 3 i APPLICANT INFORMATION Parcel Size. I OS A �- Owners Name: m L ?` ' S Q A A) Owners Address: S C�0 2 L,>j 1D92—HAtf) gS938 Telephone No.: 393- 2&02 �/1 N P)Erzee /3 Situs Address: % eospl Proposed Use: Residential New Single Family Residential ❑ Single Family Addition ❑ Mobile Home ❑ Residential Accessory ❑ Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other ❑ Septic ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necessary): ❑ Single Family Remodel ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) ❑ Approved M Conditionally Approved ❑ Resolve Problems Prior to Approval ® Site Plan Stamped Approved By Date Li Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: ❑ Snow Load Area: ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) ❑ SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: X • Flood Panel No.: O S 2- Index Date: ❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance ------------------------------------------------------------------------------------------------------------------- ❑ Detached Building Use Form ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: S R — Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Zoning Code Streets. & Highways Fire Prevention Subdivision Map Fronts- - p Side Side Street Rear Height Waterway NIA N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 a Applicable Development Fees: Standard Fees Amount Formula ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ® Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other -------------------------------------- Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation:[] No ❑ Yes Comments: ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 fm Subdivision Map/Parcel Map: bU rLHA,, Lrvt.)j-> 0 S -T P H y Map Date of Recording: Z.:,—) 6— d 2} Lot: 33 ❑ Use Permit/Minor Use Permit Permit Number: Book: I S t Page: 3�; 3-7 Date of Approval: Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval• ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be - prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. El u Page 4 of 5 7 AWES 1. TJ -HS SHEET SHOWS ADDITIONAL INFORMATION. IS FOR ADDITIONAL INFORMATION PURPOSES ONLY. DESCRIBING CONDITIONS AT THE TIME OF FILING AND IS NOT INTENDED TO AFFECT RECORD TITLE INTEREST. 2 A SOLID FENCE CHAIN LINK. BRICK. BLOCK OR SIMILAR MATERIAL, NOT WOOD. A MINIMUM OF SIX FEET IN HEIGHT SMALL BE INSTALLED ALONG THE SOUTHERN AND WESTERN PROPERTY LINES OF THE PROJECT. PRIOR TO ISSUANCE OF BUILDING PERMITS FOR ANY RESIDENCE IN PHASE 4. 3. DEVELOPMENT OF ALL LOTS IN THIS SUBDIVISION WILL REQUIRE CONNECTION TO A PUBLIC WATER SUPPLY. 4. SHOULD ANY ARCHAEOLOGICAL OR CULTURAL MATERIALS BE ENCOUNTERED DURING PROJECT CONSTRUCTION, SITE DEVELOPMENT SHALL CEASE AND ARCHAEOLOGICAL CONSULTATION SHALL BE IMMEDIATELY RETAINED. 5. ALL ALMOND TREES SHALL BE REMOVED FROM THE PROPERTY. REMOVAL OF TREES CAN FOLLOW THE PROPOSED PHASING PLAN SHOULD ACTIVE FARMING CONTINUE AS THE PROJECT IS DEVELOPED. 6. A DEVELOPMENT IMPACT FEE FOR SHERIFF'S FACILITIES SHALL BE PAID PURSUANT TO THE PROVISIONS OF CHAPTER 3. ARTICLE OF THE BUTTE COUNTY CODE, PRIOR TO ISSUANCE OF BUILDING PERMITS OR USE PERMIT IN THE CASE OF A MOBILE HOME PARK. SAID FEE AMOUNT WILL BE DETERMINED AND CALCULATED AS OF THE DATE OF APPLICATION FOR THE BUILDING PERMIT OR USE PERMIT. 7. ALL OAK TREES ON THE PROPERTY SHALL BE PRESERVED EXCEPT FOR THOSE REQUIRED FOR ROADS, DRIVEWAYS, OR BUILDINGS. A NO DISTURBANCE SETBACK SHALL BE PROVIDED COMMENCING FROM THE OUTER EDGE OF THE OAK TREE CANOPY. �5��-3537 646- 0'2, ADDITIONAL INFORMATION SHEET auFNIAM LAND E -8 -TATE, S PHASE 4 A PEMW Sir SLAS NSIM BEIMQ A POR77O f OF SHE REMAINING >N.,HAltr1 .ANC) EST'AS PHASIC' Ir SO 151 OF MA -.M. fi�,4� i'��-�'� ALSO BMW A POt�1701V dF 7iH SOUTHEAST V- 4 OF S�C7ION 2 TOWNSHIP2-1 NOR-lh NANGE I EAST' 1� A POR -170 OP' 66r vESW 114 OP �ri.►�•r�►i.• 0.^ 1" Ar00%Aft'r'i! August 13, 2003 County of Butte- FIRST CHECK Jurisdiction Appi .NoR03-119 LP2A Job No. 26615-011, Stan Merritt ' 5602 Macanarlan Lane Durham, CA 95938.. Re: Plan Review: Merritt SFD Address: La Rose Court Dear Mr. Vieria: Linhart Petersen Powers Associates- (t_P2A} has._ completed an initial review of the following documents: 1. Plans: One (1). copy plan sheets 1 through 8 (8 sheets) title sheet dated April 16. 2003 by Gregory A. Petiz Architect. 2. Structural-Catculations: One (I) -copy. -by Gregory A. Peitz Architect 3. Title 24 Energy Comptiance. Documentation- One - dated_ m (1.) copy April 2.1,_ 2003 by Gregory A. Peitz Architect. 4. Truss Calculations: One (1) copy dated March 25, 2,003 by MiTek Industries, Inc. Note: Floodplain Mitigation Measures and/or comments will be reviewed by Butte County. These documents were reviewed only for their conformance to the 2001 'California Building, Plumbing, Mechanical, and Electrical Codes. Our comments- followonthe-attached-list. Please submit an itemized response letter and two (2) sets -of complete -and, revised- document with all revisions clouded. Sincerely, "LINRART PETERSEN POWERS ASSOCIATE=S Roger terson, S.E. Mike Bayless Structural Engineer Plans Examiner KB/MB:rs is\pendingplanreview\butte\2d3015-011.doc enclosures WMr. Michael Moira, County of. Butte,. Fax: (530)-538-214,a LINHART PETERSEN POWERS ASSOCIATES 76)0 Auburn Boulevard. - Citrus Heights, CA 9561.0 (91.6) 725-4200 - FAX (916) 725-8242- • T611 Free(977) 235-065.-- Merritt SFD La Rose COurt- August 13, 2003 County of Butte - FirSt Mel* LP2A Job No.., 2030015.011 Page 2 Re: Occupanty.Group(s): R-3tUA Type of Construction: V -N Stories: Two - Building Area (sq. ft.):' 3333/910845 - covered porch A. The following plan review documents are based on the County of Butte Building Regulations. For your convenience, the followingcomments, are_ referred to the 2001 California Building Code unless otherwise noted. B. Please respond in writing to each comment by marking the attached comment list or creating a response letter. Indicate which. detail, specification,-. or calculation.shows> the requested information. Your complete and clear responses will expedite the re -cheek and hopefully, approval of this project. Thank you- for your assistance. C. For clarity, specify on cover sheet that the 2001 CBG CMC; CRC,' CEG. as amended by State of California_andlacal.iurisdictiortare applicable to this project. D. Please be sure to include on the resubmittal the architect's/engineer's "wet" stamp, signature, registration number and expiration date on all_ sheetsof plans-.[,all-.sheets_of plans depicting structural designed elements] and cover sheets of specifications and calculations. UBC 106.3.2 ARCHITEETUM— A1. The plans show the garage "fire wall separation" extending to the garage ceiling; and the ceiling is showry protecteduvith twalayers of/2' type "x" gyp. This is not an assembly recognized by the code as an adequate occupancy separation. Please either provide an -assembly whicITis- found- in the_cade,.or provide the listingfor the currently specified assembly. CBC TABLE 7-C, Item #21; Sheet 1; CBC 302.2, 302.4 Ex. 3 A2. Amend the plans for shower and tub/shower walls to specify a smooth, hard, nonabsorbent surface -(e.9:, ceramic.tille). over-a_moisture_resistant undedayment (q,.g,. w.r. gyp) to a height of 70 inches above the drain inlet. Sheet 1, CBC 807.1.3 A3. Amend the floor plans to show additional smoke detectors outside the Master Bedroom. Sheet 5', CBC 310:9:1.4 A4. Locate an 18 inch x 24 inch crawl space access on the floor and/or foundation plan. Sheet 1, 3, CBC 2306:3- A5. Amend the floor plans to show a -minimum -36 inch -deep: landing -outside -all exterior. daors (not more than 8 inches lower than threshold for in -swinging doors, and not more than 1 inch lower than threshold for out -swinging- doors)- - garage> -man -door. Street --1;_ E,BC 1003.3.1.7 A6. Specify a minimum 1/4 inch per ft- slope for weather-exposed-landingsrbalconim..and-roof decks which are sealed underneath - please clarify how the under -porch area is to drain if it is unsealed. Sheets 1, 3, CBC 1402:3- Merritt SFD Le Rose Court August 13, 20,03 County of Butte - First Check LP2A Job No:: 20300.1.5-011 Page 3 AT Specify the make, model number, and I.C:B.O, evaluation-, reporLnumber- (or othe-r approved listing) of the metal fireplace on the plans. Sheet 1, CBC 3102.5.1 MECHANICAL PLUMBING AND ELECTRICAL COMMENTS: A8. Specify a smooth metal duct for the dryer exhaust which extends outside with a backdraft damper. Sheet 1, CMC 504 and 908' A9. Amend the plans to specify that- shower and- tub -shower- combinations shall be -provided with individual control valves of the pressure balance or the thermostatic mixing valve type. Sheet 1, CPC SECTION -420.0- A10. Amend the plans to specify receptacles at the frwt_ and rear- of the_ h e. and thaithey must be within 6 feet 6 inches of grade (and waterproof and GFCI protected). Sheet 5, CEC SECTION 210-52 A11. Amend the plans to specify that the two small appliance- braneh- circuits_ for. the kitchO. are limited to supplying wall and counter space outlets (note they cannot serve the dining room, outside plugs, range hood disposals-, dishwasherst of microwaves- --Only- therequired countertop/wall outlets including the refrigerator. Sheet 5. CEC SECTION 210-52(b) Al2. Locate an electrical service panel -on the-ptartts.and-show-the-arnperage. size. Sheet 5 A13. Specify the light fixtures in tub or shower enclosures -with. the -Iabek "suitable-.fOL damp locations." Sheet 5, CEC 410-4(a) T-24 ENERGY CQMPLIANCE COMMENTS: No Comments STRLJGTt1RAL.CQMMENTS S1. Provide a note on the plans to indicate the governing code for this project is the 2001' CBC. CBC 106:1,.3 S2. Provide structural specifications--clearly-indicated.:on::the- Plans- fou the: follawing_Aems,_to corTespond:with the structural calculations: 1. Concrete strength for all footings and slab 2. Grade..of, concrete.reinforcemeut. 3. Type of nails & bolts used for this project 4. Grades-ofzait.dimension-&manufactured-iumher 5. Pressure treated sill plates S3. Provide a note on the plans- to-indicati--that-gkxKWamnated--fabrication,.shall-he-.peiformed in an approved_fabricatoes_�hop in accordance with CBC 1701.7. CBC 2304.4.3 S4. Provide -a note -on -the- plans- -to-- indicate-- that glued4aminated -beam.inspection certificates shall be submitted to the field inspector prior to completion of the frame inspection in accordance with-CBC-1704:6-2- Merritt SFO County of Butte - First Check La Rose Court LP2A Job No-: 2030015-011 Page 4 August 13, 2003 S5. Amend the plans to specify the camber for the glued laminated beams; or il_ no -camber, then. so -indicate. CBC 1.06.,3.3 S6. Provide a minimum nailing table on the plans, in- accordance= with. -CBC- Table. -23466-1. CSC, 10&.1,21 S7. Revise the shearwall schedule to indicate the- spacing-of-the-A35--anc-.ors:for-each_type_0 shearwall, as indicated in foundation details 4/8 & 10/8. CBC 1605.2 & 1633.2.3 S8. Clearly indicate all post sizes on the plans for this project. CBC 106.3.3 S9. Provide structural details to indicate the following items: 1. Indicate shear transfer from-the.garage-rooEdiaphmgmalong_the-rightwall line into through the floor and into the exterior shearwall. 2. Indicate the connection of -the -garage rflof_rafters_to-the_ridp_bea[R 3. Indicate the end walls of garage are to be balloon framed from the bonus room floor to the roof -diaphragm.-.- 4. diaphragm.>4. Indicate the connection of the jack trusses at the front porch to the exterior wall along the. left -wall line- of the -house. S10. Review and revise the wall connections tv the rno--diaphrag . for. forces_peMendicu{aLto the walls for this project. Provide a direct connection to the diaphragms for out of plane wall forces. For example, detail 618: CBC -t695.2 S11. Review and coordinate the length of the CS16- strap=indicated-1a section--9=2-arid-the-hoof framing plan on sheet 4. CBC 106.3.3 S12. Amend the roof framing plan and section B-2 to clearly indicate the required nailing of all CS16 straps. CBC 1633.2.3- S13. Provide structural calculations for the 2x8 rafters :-employed- at.- the- garage.-- In,, tt e calculations, demonstrate a single 2x8 rafter is adequate to the support the roof and pony wall at the roof pitch change. CBC %05, t S14. Amend the lateral structural-caleutattoms to-include-buildir�9 redundancy,calculaiions� in accordance- with CBC -1630;4A—:8:1.630..2.3.4. Revise -the -drawings. as required. S15. Revise the structural calculations for the 2'-6" long shearwall at the garage, as indicated in the structural calculations on page -6 sirice-the-height-to-width-ratio-does_-nnLconform-to Table 23 -II -G. Please note, since this project is located in a seismic zone 3, the maximum height -to -width ratio is 3.5:1-. CBCt68.5.2 S16. Amend -the garage shearwaWoverturning=calculations-on:- page -6,,:since--the-T.5' sheancvall height is too low. Please note, the double top plate height at the garage is 9.4', as indicated on building section- B 2/2: -CBC--t6-30;8 - ' ' S17. Provide structurah calculations= and,. revise= the -plans< W-.indicate_continuous_chords-.aed collector lines for the diaphragms for this project, include chord, collector (drag struts), and ties around:openings.in accordance- with=CBC-16-33:2:5;16,33:2,6=&=231.5,5.2. Merritt SFD La Rose -Count-: August 13, 2003 County of Butte.- Fjmt_Cbe_k LP2A Job No.: 2030015.019 Papa 5 S18. Revise the roof framing plan to clearly indicate continuous-chords-at:the,angles-walls-a_t the dinlnq<r.--ocm & n_ook..P lease, n ole,, s traps a re r equired a t t he v arious t op plate butt splices. CBC 1633.2.6 t Prefoaeufactuced-RoaTrusses l S19. Amend the plans to clearly indicate all post sizes below the girder trusses for this project Clearly indicate-a-C=plete-vertical.toad_p-ath from truss to the wall, through the floors to the foundation. CBC 106.3.3 & 1605.2 S20. The engineer of record shall amend the plans as- requited•= upon-msubr.r ittalrto_pmvide details indicating that uplift at all trusses has been considered and a complete vertical load path to the foundation has been provided -for these -trusses -via -the -plans -and -details -MC 1605:2:2 &=16052-3, S21. The nremanufactured roof- truss engineer shalt- review-: andm. coordinate -the- num he[. -of bearing points for truss types "A, Al, A1A, A3, B, BGE & C", in accordance with the roof framing plan on sheet 4 prepared by the engineer of -record: EBC460� 2 S22. The oremanbfactured- roof- truss- engineer -shat!_- amend-- alt appropriate_ root. truss calculations and plans for the drag forces specified by the engineer of record for this project upon resubmittal'. CBC -16052- S23. The premanufactured roof -truss en ineer shalt--ambnd-the-roof=tum-calculations_for-moot truss type "A4" to include the weight of the attic mounted FAU, as s hown o n t he r oof framing plan on sheet 4 by the engineer of -record. CBC -1605:2 S24. The premanufactured roof truss engineer shall- provide truss-- to. truss-. conaectiOnn calculations-and:plans..indicatng_hanger. sizes.andlocations upon resubmittal CBC 1605.2 SOIL / FOUNDATION COMMENTS S25. Provide structural notes on sheet 3 to indicate that the subgrade is to be prepared in accordance-with_.CBC-331:2,�33a &3113A S26. Revise the foundation plan on sheet 3 to indicate the anchor bolt spacing for all shearwalis employed for this project, since some are- not shown-on-the,plan.-CBC--1-632.3 S27. Revise detail 1/8 to indicate shear transfer--frorn-the, deck- diaphmgrn--into- the ... continuous foundation-CB-C-1.605.2- S28. oundation_CBC _1.605..2 S28. Amend detail 2/8 for the following items: - 1. Indicate:the-roowr-edreinforcementforthe.. 1- 6-" s4uare- spread. footink 2. Indicate the connection of the 4x6 girder to the 4x4 post. S29. Amend foundation details-2/8� 4/6 5/&,-94/6--&=1:1-/8-taindicate_BCLftomjpisis-_.as.-indicated on the foundation plan. CBC 106.3.3 S30. Revise detail 5/8- to indicate- shear-traWer- from- the-floor-diaphragm_-inta.the :contirnuQus foundation. CBC 1605.2 & 1633.2.3. Merritt SFD County of Butte - First Check La Rose Court LP2A-Job No.:. 2030015-411, Auggst 13, 2003 Page 6 S31. Revise the foundation plan on -sheet 3-to-indicate-tt►e--Gonnedion=-Of-the-2x6-ledge -aLthe, front and'rear-deeks=to--the:e)derior,wall. CBC 106.3.3 & 1605.1 S32. Amend the foundation plan to indicate the required reinforcement for all spread footings employed' for this project.- CBC: 1:06-;13- S33. Amend' the foundation- plan- on- sheet -3 -,--at= ft_—garage,- to--indicateAhe- required --slab reinforcing & gravel sub base, in accordance with CBC 1907.12.2.2 & 1825.2 If you have any- questions regarding-. the- above- eomrnwts,-please contacLRoger Reters_o0 Structural) a nd/or M ike B ayless ( Non-structural) a t( 916) 7 25-4200 b etween 8:00 A M. t o 5:00' P.M., M=F. [ENDI 0� - 4�o - bt(o .-A -0 j*1 O-ARAOL E GEILINGS MEm5RANE GON515TING of TNO LAYERS OF 112 E 'X'(5yP5UM BOARD, APPLIED PERPENDICULAR ,TTOM CHORD. THE BASE L/4.Y'ER 15 ATTACHED WITH 5. TYPE '5'5(-'REt45 SPACED UP TO 12v O.C. THE FAGU N5TALLED WITH THE JOINT5 STAGGERED FROM THC THE FACE LAYER f5 FA5TENED WITH 2" LONG TREWS, WHICH ARE 5PACEu 1:2" O.C. IN THE FIELD AT THE- BUTT JOINTS. AN ADDITIONAL ROW OF TYPE 1 11:2" LONG ARE 5PACED e," O.C.-AND ro" FROM E OF THE BUTT JOINT. THE FACE LAYER MUST BE 17H L L -p HEATER ANO .ATCsP-4 !E,:' PLATF,-,).R X T (L N 4 7 - rl, 14 BUTTE COUNTY BUILDING DIVISION' APPROVED E3 11 I `5._.: ._.: SERA/ ir E LINO T.CL6. UP 05-' f;Z; 3 7S lti:f 1=1 T. IIl f _ff <1 I HALL HOIN000 q, C_L( WOOD W ` (Rev. 12/96) COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7563 PERMIT NO. , - - APPLICATION AND PERMIT 1 ASSESS()(i�i>�=EI�I�L1t1BEbW �UJ](17�9, (�LHUiI��-VL"1 ZONING BUILDING PERMIT OWNER STAN _MER,itTIT 343-2002 TELEPHONE SO. FT. OCC. � BUILDING VALUATION 1 OWNERth](U y MACANARW LANE DURHAM CA 95938 910 L , OR'S NAME CONTRACT145 KEVIN PIERCE 895-1113 TELEPHONE C— 90 •M 77 W cONTRAC_Tf ROWM9 CHICO CA 95927 CONSTRUCTION LENDER i ,Fireplace A 1500 00 LENDER'S MAILING ADDRESS _--.- - --"' 'Total Valuation $ 207. ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 1011.7,50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $662.98 BUILDIN 4326 S 111, ROSE Cr DURHAM CA Energy Plan Checking Fee $ $ PERMIT FEE $ 1791 LOT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE v( Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap , 1 7.00105.00 Solar or heat pump water heater 23.00 Water piping 15.0015• Each as water heater or vent 15.001• 0Q 1 ` p TYPE OF WORK New11 Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 3 Rt1 M 9_ S BA NEW TTJ( _E F'sAM Y ' Gas piping system 1 - 5 outlets 15-0015.00 Building sewer 15.00 Mobile Home I S I G JW @20.00 SPRINKLER ,t 15.00 PERMIT FEE $J20Q.00 ELECTRICAL PERMIT Fling Fee 20.00 r' 80V OR LESS Main Service 200A ...SS23.00 3.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. � 35 % OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A To WEL OCso NEW CONST. ( DCU 3.50FT. OR ADDNS. & . 148. 51 NEW CONST. MULTI -OUTLET -OUTLET NON•RESID. BRANCH CIRCUITS@7.50 PO'..RA 8 SINGLE R AOUTLET XIII. OUTLET OR FIXTURES 20 Q 1.00 Ex. Occup. SAL p .50 R 5.00 Ex. Occup. oUTLEeDrsA a,6.) E temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $191.51 WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as, provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Fling Fee 20.00 Heating• 15 00 30.00 CoolingQQ Hood 6.50 0• Ventilation • • PERMIT FEE $ VIY• Policy Number "• (The above sections need not be completed if the permit is for work of a valuation of one hundred dollais ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in: any manner so as to become subject to workers' compensation laws of Calffornia, and agree that f 1 should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. )� % X /t ^-�-" " Date `//01 01 0 3 Signature of Applicant - ❑ OwneTX Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. /� ^� Mobile Home Installation Fee $ Energy Inspection Fee $ 4 • UU OCC CONST. TYPE TOTAL FEE $ 2258.88 HAZ. D. FEES P `i� OD CDF .... PARCEL r PD V ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code'and/or Resolutions to do work indicated above for which fees have been paid. B•, [,�gk/�� � Date IV PERMIT EXPIRES ON 'Date Receipt No. fL� �� �� �i "x �'%� �a � �� ! �� �, y�,/ WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT NOTES Fye " RESIDENTIAL ' 039-460-090 PERMIT NO. MERRITT, STAN 93�/ LAROSE CT, DURHAM (Cont: PIERCE, KEVIN NEW SINGLE FAMILY w 1 SPECIAL 03-1199 CHECKED BY SRA - FLOOD CERTIFICATE REQ. ` FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS ' VERIFY e USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER OFFICE COPY 1 I Address GAS Meter By DatLiELECTRIC'/Meter r ByDaattW I �j t JOB FINALED (Date Signature J=OK = Not OK - RESIDENTIAL(. = Not Applicable Read . =Not Ready — _ Date UNDERF OR (Plans) OK except #'s 1. in -Setbacks-Easements-Flood-Slope 2, F .Main; Soils-Elec. Grnd.-/ Ftg. Depth Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches &Decks; Soils -Steel -V? " Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stem , Garage; Steel-Blockouts-Wrapped 6 Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V, Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. OF as Pipe; Size Anchors -Yard Gas Piping; Size Test 14,4Vater Pipe; Test -Anchors -Regulator -Service Test 12. Electr' nder round 13. PI ums & Ducts; Clearance -Material -Support -Ins. 1 irders-Sills Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation Insulation Date Card B- Date -7a`{ Card B-1 DateCar -1 Date �-g -�/ Card B-1 Date PL B e it) OK except #'s ater tr.; Vent -Access -Combustion Air Baffle le-D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shovy4r Pan; Test, First Floor -Tub Access 21. jPXTub & Shower, Second Floor -Tub Access Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test Date Card B-1 Date ' Card B-1 Date Card B-11-1--- Date Card B-1 Date ELECTB A (Permit) OK except #'s 24-'IFtxjdre,WTransformer Clearance -Ins. Protection 2 e eceptacles Spacing -Lights & Switches at Doors 2� es & No. of Conductors Stapled 27 a Installed Close to Edge of Studs & C.J. 2Aelfgdip. Gpwfid made up w/Mech Fasteners -Bond Gas & Water 12%92 A lance Circuits in Kitchen & Conductor Size GFI ub ed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ . /g C r Al ange Circle/ /qa Cu or AI -Oven Circ. / / a Cu or Al Insel'ated-Neutral 9 -Yes O No 3i'Se e ' -Ri er Conductors & Ground Main Disconnect 33. ui P. earances Panels-Motors-Mech. Equip. CI es Closet Light -Shower Light -Spa Light Smoke Detector Date Card B-1 Date Card B-1 Date Card B -V Date Card B-1 Date MECH CA��jP r it) OK except #'s 3".C. P,.Insulation & Support aZ-4169VW, Exhaust above insulation densate Drain & Overflow, Size & Grade 3 . Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40!Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s /4ysip Proper Materials & Anchors Studs -Nailing Spacing & Braces -Plates -Sound L4_3Aearing Walls over Girders & Floor Nailing 7-c4fbraft Stop in Walls (rat proof) Wire Stops, Furred Ceilings -Stairs -Chasers -Tubs (46j4eaders & Beams -Size & Bearing jingle & Duplex) Date FRAMI Continued) 4 a ens P 9't Caps -Anchors -Connectors 48. Ii oist-Rftr. Ties- Purlin-Roll Brac.-Truss-Shting.-Rtng. 4 :,Fireplace Ties or Type A Flue -Fireplace Throat Clearance d. AttiiC, cess; Size & Romex Protection -Draft Stop -Ins. Baffles !D . drm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Pr2pigrty Line Firewall & Openings - f 5 xt. Door -One 3' -Check Garage 3rd Story, 2 Exits 55. Sta' , Width-Headroom-Rise-Run-Landinq-Fire Protection t. ywood on Roof Overhang -Attic Vents -Rafter Outriggers 57 _ inq-Nailinq Veneer 58. Styefo Mesh -Drip Screed -Fd. Vents-Underflr. Access Area -Glass - /x,,6'1. _6fape Interior/Exterior Wall Panels '63. Infiltration -Wal . dows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL P s) OK except #'s Steps -Door & Sidelight Protection -Landings 69ISmqXerbetector urnace Vents -clearance -Comb, Air -Connector - In arage; Above Floor-Ducts-Mech. Protection 68!G. Bath Fixtures & Tub Access -Spa ' Trim & Subpanel, Breaker Sizes & Labels S ' s & Rails . Fireplace or Stove, Clearance -Hearth EI . Outlets at Wood Panel, Int. & Ext. 78'-Kil F&t. & Appliance; Ground-Air-Gap-Cookinq Clearance Z4r .Outlets & Receptacles at Kit. Counter 71 -Gaffe Fire Door; Swing -Landing -Closure 7 ..C%Duct in Garage -Damper 7.7!Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in ge; Above Floor-Mech. Protection 7 .; Elec. & Mech. Equip. Listed for Location (Mleggeceptacies in Garage (F.F.I.)-Romex Protection sulation-Foam-Looked in Attic 81. Gyafd Rails & Deck Construction -Post Caps dn. VBents & Crawl Hole Door Drainage & Wood -Earth _ Clearance Looked under loor 0 Yes 83!ollowing Instld./Drive s 0 No/Walks 0 NovPlanters es O No 84. Stu o Brown -Finish C. Unit Disconnect, Electrical -Plumbing aia-AwfiAbove Roof, Plbg-Appliance-Fireplace-Clearance to Openings at Well, Disconnect, Electrical, Plumbing 8 xte ' lec. Trim, G.F.I. Receptacle -Underground entlation Throughout House QQ-913ss Protection Corre o s -from Previous Inspections 9 as st-Meters Tagged, Gas -Electric ate Sewer Connected -C/O to Grade -HD Approval n y Compliance Certificate -Other Certificates (95Wddress Posted 96. Fire Sprinkle Dater •-(%S Card B-1 Date Card B-1 Date and B-1 Date Card B-1 Date Card B-1 V Date Card B-1 Comments at Final: J=OK 0 = Not OK . = Not Readyable MOBILE HOMES Date FAOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/0 -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or / /" L "ft./ P LPG MISCELLANEOUS Date 7. Well Clearance & Disconnect 1. 8. Utility Clearance 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 7. 1. Zoning Requirements -Setbacks -Easements 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 2. Footings;"Size-Spacing-Marriage Line Siding; Nailing -Veneer -Stucco -Mesh 3. Gas; MH Test -Demand -Valve -Connector Roof; Shthg-Roofing 4. Electricity; MH Test -Crossovers -Breakers -Clearances 11. 5. Drain; MH Test -Fall -Flex Connector 12. Braced Wall Panels 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O tc Grade -HD Approval Card B-1 Date Card B-1 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. POOLS (Plans) OK except #'s 10. Exits; Insp.-Sketch Setbacks -Easements 11. Cert. of Occupancy Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 7. 1. Zoning Requirements -Setbacks -Easements 8. 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 12. 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged "9. Exits 10. License Decals 11. Verify #'s with- Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #s. 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams-Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors . 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes -Enclosures- Panel boards -Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 i' 4f INTER -DEPARTMENTAL MEMORANDUM rl TO'--, BUILDING DIV SION, O OVILLE FRAM: ENVIR. HEALTH, CHICO DATE: RELEASE ENV. HEALTH HOLD ON BUILDING FINAL FOR: OWNER NAME: zgkL�— SEPTIC: WELL: o/ ADDRESS/LOCATION: Comments: GUmemos/releasehold TT BUE COUNTY OCT 14 2004 DESELOpMENT f'" "'�\ .. _.. .� _ ,� ,r ,:� � ;� y f �R Is„ �� .f.1. _. „. �11]jjj([� � x ,� jj � 41t :1.4F _ _ _ �., '�