Loading...
HomeMy WebLinkAbout039-460-093NOTES RESIDENTIAL 039-460-083t 02- P 3310 PERMIT NO. - MARTIN, LEE &r ALI 9368 LA ROSE CT., DURHAM CONT: STORNETTA BROS. NEW SINGLE FAMILY W/GARAGE _ SPECIAL CONDITIONS i CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY - USE PERMIT CONDITIONS SUB-STANDARD HOUSING LETTER OFFICE COPY - Address GAS Meter By Date` ELECTRIC Meter By Date I JOB FINALED (Date) i69c 3 _J Signature J=OK 0 = Not OK - = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) .'- Date ' - Date UNDESFLOOR (Plans) OK except #'s L/FtgfMain; Soils-Elec. Grnd.-//Z /" Ftg. Depth g. ,Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth tg,.eKrches & Decks; Soils -Steel-/ /" Ftg. Depth Stemwalls, Main; Steel-Blockouts-Wrapped Ga!HgWODowns and Special Anchors lab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9!D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15: Access & Ventilation 16. Insulation /% Date Card B-1 ✓ Date Card B-1 Date Card B-1Date Card B-1 Dante ' P MBING (Permit OK except #'s 7. WatW ttr.: Vent -Access -Combustion Air Baffle Test Fittings & Anchor -Nail Protection dr•, ' o '-&J 30 ower Pan: Test. First Floor -Tub Access Date 2Z,09s Pipe; Sixe & Anchors 23. Fire Sprinkler; Test F ri Exhaust above insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECT_MAL (Permit) OK except #'s Date 2 ix re & Transformer Clearance -Ins. Protection Date 2 ec.. Receptacles Spacing -Lights & Switches at Doors Date 2 izgiBbxes & No. of Conductors Stapled o9m6i Installed Close to Edge of Studs & C.J. io. Ground made up w/Mech Fasteners -Bon as & ter 29-12 Appliance Circuits in Kit n & Conductor Size GFI '1feed Wire Size/ („ /g C r AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cur AI -Oven Circ. / /ga Cu or Al Insulated Neutral Yes O No t 32. Serv' -Riser Conductors & Ground Main Disconnect p. Clearances Panels-Motors-Mech. Equip. Ids Closet Light -Shower Light -Spa Light moke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECH ICA Permit) OK except #'s C. Do6tonsulation & Support F ri Exhaust above insulation ZAo9densate Drain & Overflow, Size & Grade Xace-Vent Access -Comb. Ait-Return Air Vent 115 Outlet *60"Attic Access & Platform if Furnace in Attic Date Card B-1 / Date Card B-1 Date Card B;)Date Card B-1 Date FRAMT& jKrmit) OK except #'s roper Materials & Anchors alls Studs -Nailing Spacing & Braces -Plates -Sound 43. BSortlIg Walls over Girders & Floor Nailing raft Stop in Walls (rat proof) L4,!! r tops; Furred Ceilings -Stairs -Chasers -Tubs 46-'0HP,qriers & Beams -Size & Bearing A, Date FRAMINUContinued) 48e<in�jst'Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 49,41epidbe Ties or Type A Flue -Fireplace Throat Clearance 5 is Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5 Windows or Exiting Doors -Sill Ht. & Dimensions 5 qe Fire Protection Framinq-RC Channel 53. 5¢ ExLR'bors.One 3' -Check Garage 3rd Story, 2 Exits 55. Stai idth-Headroom-Rise-Run-Landing-Fire Protection Vents -Rafter Outriqqers 51. Sidi g -N "ling Veneer %tTresh-Drip Screed -Fd. Vents-Underflr. Access Wall Panels /63C4f filtration-Wa -Windows Date—l-j—G3 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FIN tans) OK except #'s xt. Steps -Door & Sidelight Protection-Landiigs Smoke Detector .66s Furnace Vents -clearance -Comb, Air-Connector- _,IRGarage; Above Floor-Ducts-Mech. Protect.on Broom Exiting .F.I. & Bath Fixtures & Tub Access -Spa W. Elec. Trim & Subpanel, Breaker Sizes & Labels -i9r tairs & Rails fireplace or Stove, Clearance -Hearth c. Outlets at Wood Panel, Int. & Ext. i . Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance V.Xlec. Outlets & Receptacles at Kit. Counter Pf G age Fire Door; Swing -Landing -Closure d.6-. .C. Duct in Garage -Damper /91'tr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. Zarage; Above Floor-Mech. Protection b.; Elec. & Mech. Equip. Listed for Location lec. Receptacles in Garage (F.F.I.)-Romex Protection . Insulation -Foam -Looked in Attic -8t- Guard Rails & Deck Construction -Post Caps -62v Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 174 83. F lowing Instld./Drive O Yes O No/Walks O Yes O No'Planters O Yes l7 No .'s(ucco Brown -Finish �eff. Unit Disconnect, Electrical -Plumbing is Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings ter Well, Disconnect, Electrical, Plumbing teVCerior Elec. Trim, G.F.I. Receptacle-Underg,ound W. Yofiqlation Throughout House ass Protection rrections from Previous Inspections Test -Meters Tagged, Gas -Electric VjKtgr & Sewer Connected -C/O to Grade -HD Approval ergy Compliance Certificate -Other Certificates Address Posted 96"' Fire Sprin Dat Card B-1 -Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: J=OK a 0 = Not OK = Not Applicable . =Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Gas; Location -Test -Wrap;-/ P' L 'ft. / P Nat. or/ /" L "ft./ P LPG 1. Zoning Requirements -Setbacks -Easements 7. 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext:; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ P' L 'ft. / P Nat. or/ /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext:; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION . 7 County Center Drive • Oro\tille, California 95965 • Telephone (530) 538-7541 .PERMIT 110. (Rev.12(96) - ". APPLICATION AND PERMIT ���� ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER TELEPHONE s�Qc, n� � SO. FT. OCC. BUILDING VALUATION 7 - q00 OWNER'S MAILING ADDR S .- 2-315 �` M O q 1 tt CONTRACTOR'S NAME TELEPHONE CONTRACTORS MAILING ADDRESS ., 106-46 '9011TH MILLER AVE.7f1 n CONSTRUCTION LENDER - r r .- Fireplace LENDERS MAILING ADDRESS Total Valuation$ q ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS AIAR LA, ROSE My M Energy Plan Checking Fee $ $ PERMIT FEE $ 1 Z r) LOT NO. ` n SUBDNISION'S NAME PARCEL MAP PLUMBING PERMIT Filing F&i 20.00 Each Trap 7.00 USEOFSTRUCTURE SF_4 Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK Neww Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: N ,W STN(;T.F FAMTT.V Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE $ rv-, ELECTRICAL PERMIT Filing Fee 20.00 Main Service xa0A OR LESS 23.00 LICENSED CONTRACTOR'S 'DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER - 'License Class Lic. No. 15 1 1 " i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELUNG OCCUP. OR ADDNS. ( 8 ACC. BLDS. SO 3.5¢FT. NOµHESID. MULTI- CIRCUITS OUTLET @7,50 APPARATUS b SINGLE OUTLET CI R. Ex. Occu OUTLET OR FOTTURES 20 BAL @ .50 LED APPLNS. OR Ex. Occup. ETS RESIO. EA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE $ 14q SS WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor r Code, for the performance of the work for which this permit is issued. ❑/Ilave and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier�CT,- C S;.� .. c 1r--. �. ., Policy Number �s1 Z ".� c��a �^�ta �• c>, I (The above sections need not be completed 0 the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700' of the Labor Code, I shall forthwith comply with those provisions. �� X Date 1 '1► '- -2_ — `� L Signature of App cant - ❑ Owner ❑-Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 1 20.00 Heating 1 b5_00 Cooling Hood 6.50 1-9 r1a Ventilation PERMIT FEE $76.50 Mobile Home Installation Fee $ Energy Inspection Fee $ 46.W OCC CONST. TYPE TOT L FEE $ 1 1 ( HAZ. / D. FEES IMP FLOOD CDF r- PAi)t:EL. AR �/ HD suE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date Dere Receipt No. n � 1 11S -7 G il'7 WHITE-D.D.S.-B. D. CANIRY'ASSESS0R P N -INSPECTOR GOLDENROD. APPLICANT LOERKE INSULATION CO., INC. INSULATION CERTIFICATE i. ROOF Materfal Thidctr (bu�ces) 2. CEILING Batt or Blanket Type .FNeMWs Haas Thickness (inches) .3 Loose FB Type Fiberglass Contreclo/s min. installed weVM sq.. 61 S tb, Brand Name e (R Vah�e) Brand Nam Johns Manville Thermal Resistance (R -Value) '�3g Braid Name Johns Mamr& Minimum Thiess i S • -qS inches. Iftmftchnes knuffied vveW Per square toot to admire Thermal Resistance (R VWw)1'Z3g 3. EXTERIOR WALL Material EMMON NO Thk*ness (an ) 6.5 4. RAISED FLOOR Material Thickness ) 5. SLAB FLOOR / PERIMETER Material Thwkness fthneWJas"m Deo @W"z= 8. FOUNDATION WALL f Thickness �-- Broad Name Johns Mame Themnal Resistance (R-VSW 2\` - Brand Name (R Vatus) Brand Name esistance (R-VatueL Bred Name Th(R ValueL. re 1 4,,.. i :.tet. • •. ' Genera corrtracbr ame O� � COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. i A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. d vc 5 i P6 e*. Date REV 10/92 ` —COUNTY OF BUTTE.,,. . BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA -! (530) 1391-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 r CORRECTION NOTICEAl OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is 'R completed. if you have any questions pertaining to this matter, or need additional explanation, please contact. Pis office immediately. � f �W[; t 131/-x --. —COUNTY OF BUTTE .. , . . L , , • . , ..,, BUILDING DIVISION','." , - DEPARTMENT OF DEVELOPMENT SERVICES 4ff'Main Street - Chico, CA - (530) 891-2751 7 County Center Drive - Oroville, CA - (530) 538-7541 CORRECTION NOTICE O,)- OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address an should be corrected. Please notice this office when correction of work Is completed. If yo have any questions pertaining to this matter, or need additional explanation, please contact , is office immediately. MA a & Aki'L&Aez WOV G' L ` /10 tll G� /W/z — ,j 3 d i MA a COUNTY OF BUTTE BUILDING DIVISION ........ DEPARTMENT OF DEVELOPMENTSERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-75410 L7 T (Rev.12/96) APPLICATION AND PERMIT Z- L�� ASSESSOR PARCEL NUMBER 039-460-0-&4� 93 ZONING SPI-1 BUILDING PERMIT OWNER MARTI TELEPHONE 899-0213— SO. FT. OCC. BUILDING VALUATION OWNERS MAILING ADDRESS 2315 TURNTREE C1, DURHAM, CA QSQIR 744 U 1 :399-00 CONTRACTOR'S NAME STORNETT343-6656 HONE c CONTRACTORS MAILING ADDRESS - CONSTRUCTION LENDER Fireplace 1900 00 LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Fee $ 20.00 —Filing Permit Fee $ 797-00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS Energy Plan Checking Fee $ PERMIT FEE $ LOT NO. 36 SUBDIVISION'S MIME PARCEL MAP PLUMBING PERMIT ri ling Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SFA Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 5 00 TYPE OF WORK New)i Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: NEW SINGLE FAMILY Gas piping system 1 - 5 outlets 15.00 15 QQ Building sewer 15.00 1 Mobile Home S G W 920.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service 200A OR LESS 23.00 0Q) LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is iforce and effect. _ License Class Lic. No. 15 1 �( 1 �i OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. WI have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensatio nsurance carr and policy aWber are: Carrier ST01rQ . tzs . Policy Number p%Q) 4=c� 3"-l0 — Q, j (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date i "�- — �-"' �-- Signature of ApAcant - ❑ Owner ontractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mein Service zoOA TO 10ooA v 46.00 NEW CONST. D ."NG UP. SO OR ADDNS. ( 8 ACC. Blas. 3•SQ FT. NON-REOSID. T. MULTI -OUTLET @7.50 POWER APPARATUS 8 SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FIXTURES BAL O 1.5500 FlXED APPLNS. OR Ex. Occup. 5.00 ourLETs RESID. EA Temporary Service 23.00 Mobile Home Facilities % 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating 25 QQ Cooling Hood 6.50 - cn Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 c TO L FEE $ HAZ D. FEES I OOD cop p CEL HD SUE — This permit is hereby issued under the of the Butte County Code and/or indicated above for which fees have - By PERMIT EXPIRES ON 3 applicable provisions Resolutions to do work been paid. / 3 jDate ! o ate ReceiptNo.16 0`� WHITE-D.D.S.-B.D. CANAR -ASSESSOR PI -INSPECTOR GOLDENROD -APPLICANT 1"/ E.N. U AIL7 Plot Plan Anachod _ Floor Plan Att=ftad G� Sant to B.O. U l �-- 33« TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Col 3 07 -IV Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for dwelling. Other Finrance O.K. for: NOTE: Environmental Health Specialist 8/96 *, 61 r COUNTY OF BUTTE-DEPAF�TMENT°QF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville,,tA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET 10+ 3 (_ OWNER: ASSESSOR PARCEL NUMBER Q3'� - 'Tt0 () ^ 03 rot Proposed Building Use:. 0 t AS 1 Counter Technician: Date: Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in ordei to Jpply. GY*11 .. Plot plans, 3 or 4 sets, signed,ty the preparer of the plans. QeT Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! Energy compliance design and supporting documentation in duplicate. ❑ 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The.permit will be indexed and returned to the plan review line-up when required items are received. Date Received By ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... ❑ 12. Hazardous Material Form............................................................................... _ ❑ 13. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) ees as shown on the attached Schedule of Fees Due Sheet................................3.77-5 1 Statement of Intent for Non -heated and A/C Buildings ............ ................................. V16. Sanitation and plot plan approval from the Environmental Health Department in ❑ 17. City of Chico Plumbing permit......................................................................... ❑ 18. California Department of Forestry plan approval ❑ paid. Sent. by: ...................... ❑ 19. Planning approval for (A) Use: (B)Parking: (C) Parcel Check: 12 . q -02- 0 .-A2- ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage .............................. bgkk 1. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancyy<). ❑ 2T Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... ❑ 26. Letter of Signature authorization.................................................................... %L7. Recorded copy of Agricultural Acknowledgment Statement .................................... 12- 0 28. Manufactured home utility clearance............................................................... ❑ 29. Existing violations and/or expired permits .......................................... :............... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, Check to H.C.D. $ ❑ 31. Other: When issued Telephone and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: C��(31°A �- �' Date: 1. Index permit application for the above items numbered: /A e �tter 2. AAditWnal items required i ' , esigner, owner, was advised cf the above data by ph e' • il, ❑ counter, by ..Date: l Contractor, designer, owne , was advised of the above da a by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: �� h Date: Plans approved by: _Date: Structural reviewed by: Date: Structural approved by: L Date: !Note transfer by: — �4= j� Date: , t • A Ye ow: Building Division COUNTY OF.BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE PROP G USES ILDING PERMIT FEES I I /_S , Balance Due .................. . $ , ((� Additional Fees Due ............... . Additional Fees Due ................. $ Revised Plan Checking Fee ........... $ 2. SCHOOL DISTRICT FEES o�-� at District Office) (Available after Plan Check) &:;esidential E F FEES (paid at Building Division) / ...................... —x$360. Units I Commercial (sq. ft.) ............... x $0.03—= -$----- Sq. ft. 4. URBAN AREA FEES (paid at Building Division) Residential ................... —x—=$ # Units Amt. G Commercial (sq. ft.) ............ —x—=$ Sq. ft. Amt. Ibt3C� A.P. #t - DATE Q-20-- RECEIPT # DATE REC. 375765 3,17'G RECREATIONAL DISTRICT FEES _ (paid at District Office) (Available after Plan Check) /-y -' THERMALITO DRAINAGE DISTRICT FEES `( C� �l $510.00 (paid at Building Division) _ 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) _ 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER eo Z, ( -7 / 0 -1, At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE 1 2— Pursuant Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner ' (Rev. 6/00) _�-v - r _y ,., vim..,✓'-, v. r v .� �..-v i:,.r V' �-.-;. �- .. _. _ �.... � o � - - r �- � - - - C Sa A BUTTE COUNTY PARK FAOILITY-FEE PAYMENT CERTIFICATION FORM DURHAM RE9.8EA-1 ON AND PARK DISTRICT Assessor Parcel` Number (s): Property Owner (s):��. � g3 ���� Project Location/Address: � � � �-! Subdivison Name: Assessable Square Footage: 7� . Type of Residential Development (check one): New Development Alteration/Addition Mobile Home (s) ❑ Non -Residential to Residential Comments: Building Division Representative Date Durham Recreation and Park District (DRPD) certifies that Lee Applicant Name 4L. t, L 9'2 (4 R 4 G� froc� C . Street Address C A -02-13 Applicant Phone Number I City State Zi,p Code. has complied with the requirements of the Butte County Board of Supervisors Resolution No. 93 - 114 by payment for ZZ -7 Z square feet at $ 1.04 per square foot for a total payment of $ 613P Representa ive PAID BY CHECK No.: � BANK No.: 90 -q2 -02 - PAID 0-q2O2PAID BY CASH: RECEIPT No.: J(p S LO (p Remarks: 2-112-t-1 D Date DISTRIBUTION: WHITE - APPLICANT PINK - DRPD YELLOW - BUTTE CO. BUILDING DIVISION t •,�. School District A.P. Number Property Owner Property Location/Address Subdivision Residential Development BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One f?Stg per Building) 04W Lf S 1> Building Department No. Jurisdiction: City County 0 No o Living Mobile Home Units Installation Commercial%Industrial New Addition Building Department Repre es ntat ve 6 4n Lot No. .................................................................................................................. Sq. Footage 7 Addition/ *Supplemental to (Group R) Conversion Permit # *(No foundation inspection;: ................................................................................................................... ,may, -;--_mow. -��..- ...• :,.ri_- �..._�,:. �. �: .� _ _ .. _. � .• Sq. Footage (including Exterior Roofed Areas) Irioor mans reviewed Dy Scnooi uistnct versonneu District Identification No. Date ,bu,eAlt" UN/'Cl --fl School District certifies that 7-1 AJ (Applicant) 7 -- (Street Address) (Phone Number) Du,e40-M 0 q 9S93 S (City) (State) (Zip Code) has complied with the requirements of Resolution No. 0.19-04 by payment of $ Z/ r6 ? . tJ $' representing w;?49 square feet. AB 2926 $ + jFULL MITIGATION.,.. S . � School District Representative Date Paid by Check 11 / Remarks: Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with' Government Code Section 660201a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act ICEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm ~--~-~-' -' �� -' ' --`-`'---' --��-�~-/-/-r----� 0, .s nicwthStar ENGINEERING Civil Engineers • Planners • Surveyors Al 1-21=03 STRUCTURAL CALCULATIONS PROJECT: Lee and Ali Martin Residence LOCATION: Lot #36, Durham Land Estates #4 Butte County, California JOB NUMBER: 7912 DATE: January 22, 2003 CODES: California Building Code, 2001 Edition Al CODE ENFORCEMENT: County of Butte Building Department LOADS: Seismic Zone: 3 Wind Speed: 75 mph Exposure: B (Method 2 used, u.n.o.) Soil Bearing: 1000 psf (per CBC TABLE 18 -I -A) I. NOTES: Are Special Inspections required for Engineering Elements Designed by NorthStar Engineering? No NorthStar Engineering is not responsible for these calculations unless this sheet is stamped by a registered professional engineer and wet signed with RED or BLUE ink. GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. f. Page 1 of "North$tar, 20 DECLARATION DRIVE ENGINEERING CHICO, CA 95973 BY: JMR 530-893-1600 1/22/03 FAX 530-893-2113 JOB NO: 7912 PG. 2 OF Al 1-21-03 LATERAL DESIGN BASED ON THE CALIFORNIA BUILDING CODE, 2001 EDITIONA1 GRAVITY LOADS. ROOF: COMPOSITION SHINGLES 3.0 PSF 1/2" OSB OR PLYWOOD 1.5 PSF FRAMING 3.0 PSF R-30 INSULATION (OPTIONAL) 2.0 PSF 5/8" GYPSUM WALLBOARD 3.2 PSF MISCELLANEOUS 1.3 PSF DEAD LOAD 14.0 PSF LIVE LOAD 16.0 PSF TOTAL LOAD 30.0 PSF LATERAL LOADS: SEISMIC: 2.5 * 0.36 * W = 0.200 W y 4.5 WHERE R = 4.5 SOIL PROFILE = Sd FOR STIFF SOIL PROFILE Ca = 0.36 PER UBC TABLE 16 - Q r-max=(V/2)"10/(Iw*V)=5/Iw=5/18'= 0.27778 p = 2 - 20 I (r -max * (Ab)^0.5) = 2 - 20 / (r -max * 4043^0.5) = 0.87 P = 1.00 E = p VW = 0.200 W (PER UBC EQ. 30-1) NET FORCE = 0.200 W 11.4 = 0.143 W WIND: EXPOSURE = B METHOD 2 WIND SPEED = 75 MPH Cq 1.3 DESIGN qs 14.5 PSF PRESSURE Ce 0-15' = 0.62 Cq*qs*Ce = 0.0117 KSF 15'- 20' = 0.67 = 0.0126 KSF 20'- 25' = 0.72 = 0.0136 KSF 25'- 30' = 0.76 = 0.0143 KSF 30'- 40' = 0.84 = 0.0158 KSF General Notes: 1. The engineer is responsible for the structural items as noted in the following calculations. Should any changes be made to the design as detailed in these calculations without written approval from the engineer then the engineer assumes no responsibility for the entire structure or portions thereof. 2. All water proofing and flashing (roofs, foundations, retaining walls, decks, garage floors, etc.) is the responsibility of the contractor or owner. 3. These calculations are based on a completed structure. Should an unfinished structure be subject to loads then the engineer shall be contacted for an interim design or if not, will assume no responsibility. 4. Building sites are assumed to be drained and free of clay or expansive soil. Any other conditions must be brought to the attention of the engineer. 5. These calculations assume stable, undisturbed soils, and level stepped footings. Any other conditions encountered must be brought to the attention of the engineer. 6. All footings shall bear on undisturbed soil with a footing depth below frost line (per local requirements). BY: p, t.taCdM DATE: I I Z JOB NO: -7 m ENGINEERING PAGE 3 OF Civil Engineers* Planners *Surveyors EF r 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893.2113 1 I JE 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893.2113 By: MEM No thSta " Dat2 ENGINEERING Jobob No. No. 79 7912 Page of LATERAL DESIGN SHEAR WALL LINE 1: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 �Lsw1 � L2 �Lsw2 L L3 LLsw3 L L4 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L5 LLsw5 I, L6 L1 = 1.5 FT Lsw1 = 4 FT L2 = 10.5 FT Lsw2 = 3 FT L3 = 10.83 FT Lsw3 = 4 FT L4 = 1.5 FT Lsw4 = 13.67 FT L5 = 0 FT Lsw5 = 0 FT L6 = 0 FT TOTAL LENGTH OF WALL (L) = 49 FT SHORTEST LENGTH OF SHEAR WALL = 3 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.85 K LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 6.79 K LATERAL FORCE THAT GOVERNS (V) 6.85 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 2305 FT12 DEAD LOAD OF DIAPHRAGM (DL) .= 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 149 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 110 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall./ 2) * (Lwext * Dlwext + Lwint * DLwint) W = 47.948 K TRIBUTARY WALL AREA FOR WIND (AREAw) = 581 FT^2 WIND PRESSURE (P) = 0.0117 KSF By: MEM Date: 8/12/02 Job No. 7912 Page 5 of SHEAR WALL LINE 1: NorthStar ENGINEERING (CONTINUED) 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= 0.278 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 2.50 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw/ 2 * Hwall * Dlwext) Fdwn = 0.14 K NET UPLIFT FORCE = Fuplift - Fdwn = 2.35 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V / L) * L1 = 0.21 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 0.34 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + 1-2) _ -1.13 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) _ -0.71 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) _ -2.23 K DSF6 = v * (Lsw1 + Lsw2 + Lsw3) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) _ -1.67 K DSF7 = v * (Lsw1 + Lsw2 + Lsw3) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -1.88 K DSF8 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.00 K DSF9 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 0.34 K MIN. DRAG STRUT FORCE _ -2.23 K USE: SHEAR WALL NO. 2 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 8/12/02 Job No. 7912 Page of SHEAR WALL LINE 2: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 LLsw1 L L2 NorthStar 20 DECLARATION DRIVE ENGINEERING CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL Vi PANEL SECTION, TYP. L3 LLsw3 L L4 L Lsw4L L5 LLsw5 I, L6 L1 = 1.5 FT Lsw1 = 16 FT L2 = 17.5 FT Lsw2 = 8 FT L3 = 6 FT Lsw3 = 0 FT L4 = 0 FT Lsw4 = - 0 FT L5 = 0 FT Lsw5 = 0 FT L6 = 0 FT TOTAL LENGTH OF WALL (L) = 49 FT SHORTEST LENGTH OF SHEAR WALL = 8 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.02 K LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 5.33 K LATERAL FORCE THAT GOVERNS (V) 6.02 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 1738 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 137 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 176 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * (Lwext * Dlwext + Lwint * DLwint) W = 42.116 K TRIBUTARY WALL AREA FOR WIND (AREAw) = 456 FT A2 WIND PRESSURE (P) = 0.0117 KSF By: MEM NorthS'tar 20 DECLARATION DRIVE Date: 8/12/02 ENGINEERING CHICO, CALIFORNIA 95.973 Job No. 7912 530-893-1600 Page % of FAX 530-893-2113 SHEAR WALL LINE 2: (CONTINUED) LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= . 0.251 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 2.26 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.38 K NET UPLIFT FORCE = Fuplift - Fdwn = 1.87 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V/ L) * L1 = 0.18 K DSF2=v*Lsw1-(V/L)*(Ll +Lsw1)= 1.86 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + 1-2) _ -0.29 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) = 0.74 K DSF5 = v * (Lsw1 + Lsw2) - (V / L).* (L1 + Lsw1 + L2 + Lsw2 + 1-3) = 0.00 K DSF6 = v * (Lsw1 + Lsw2 + Lsw3) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) = 0.00 K DSF7 = v * (Lsw1 + Lsw2 + Lsw3) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) = 0.00 K DSF8 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2.+ Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.00 K DSF9 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L)' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 1.86 K MIN. DRAG STRUT FORCE _ -0.29 K - USE: SHEAR WALL NO. 2 aHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 1/22/03 Job No. 7912 Page of Al 1-21-03 SHEAR WALL LINE A: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 L Lsw1 L L2 NorthStar ENGINEERING 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L4 L Lsw4L L5 LLsw5 L L6 L1 = 1.5 FT Lsw1 = 4 FT L2 = 8 FT Lsw2 = 4 FT L3 = 4 FT Lsw3 = 4 FT L4 = 28.67 FT Lsw4 = 3.92 FT Al L5 = 15.17 FT Lsw5 = 3.92 FT L6 = 1.5 FT TOTAL LENGTH OF WALL (L) = 78.68 FT SHORTEST LENGTH OF SHEAR WALL = 4 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.42 K LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 4.15 K LATERAL FORCE THAT GOVERNS (V) = 6.42 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 1949 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 156 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 143 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * (Lwext * Dlwext + Lwint * DLwint) W = 44.953 K TRIBUTARY WALL AREA FOR WIND (AREAw) = 355 FT^2 WIND PRESSURE (P) = 0.0117 KSF By: MEM Date: 1/22/03 Job No. 7912 Page of Al -21-03 SHEAR WALL LINE A: Nor#hS#ar ENGINEERING (CONTINUED) 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= 0.324 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 2.91 K DOWNWARD FORCE RESISTING UPLIFT (.Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.19 K NET UPLIFT FORCE = Fuplift - Fdwn = 2.72 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 =(V/L)-Ll = 0.12 K DSF2=v*Lsw1-(V/L)*(Ll +Lsw1)= 0.85 K DSF3=v*Lsw1-(V/L)*(Ll +Lsw1 +L2)= 0.19 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) = 1.16 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) = 0.83 K DSF6 = v' (Lsw1 + Lsw2 + Lsw3) - (V / L)' (L1 + Lswi + L2 + Lsw2 + L3 + Lsw3) = 1.80 K DSF7 = v' (Lsw1 + Lsw2 + Lsw3) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -0.54 K DSF8 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L)' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.41 K DSF9 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = -0.83 K DSF10 = v(Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.12 K MAX. DRAG STRUT FORCE = 1.80 K MIN. DRAG STRUT FORCE _ -0.83 K USE: SHEAR WALL NO. 3 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 8/12/02 Job No. 7912 Page IO of SHEAR WALL LINE B: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 LLsw1 L L2 NorthStar ENGINEERING 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L3 [,Lsw3 L L4 L Lsw4L L5 LLsw5 L L6 L1 = 7.5 FT Lsw1 = 4 FT L2 = 8.5 FT Lsw2 = 4 FT L3 = 26 FT Lsw3 = - 4 FT L4 = 17 FT Lsw4 = 6 FT L5 = 1.67 FT Lsw5 = 0 FT L6 = 0 FT TOTAL LENGTH OF WALL (L) = 78.67 FT SHORTEST LENGTH OF SHEAR WALL = 4 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.53 K LATERAL WIND FORCE ON WALL (Vw) = AREAwP = 3.28 K LATERAL FORCE THAT GOVERNS (V) = 6.53 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 2094 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 138 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 143 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIG. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2)' (Lwext' Dlwext + Lwint' DLwint) W = 45.687 K TRIBUTARY WALL AREA FOR WIND (AREAw) = 281 FT^2 WIND PRESSURE (P) = 0.0117 KSF j 1' By: MEM Date: 8/12/02 Job No. 7912 Page 1 I of . SHEAR WALL LINE B: NorthStar ENGINEERING (CONTINUED) 20 DECLARATION. DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= 0.363 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 3.26 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3.* (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.19 K NET UPLIFT FORCE = Fuplift - Fdwn = 3.07 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V / L) * L1 = 0.62 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 0.50 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + L2) _ -0.21 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1.+ L2 +. Lsw2) = 0.91 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3) _ -1.25 K DSF6 = v ' (Lsw1 + Lsw2 + Lsw3) - (V / L) ' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) _ -0.13 K DSF7 = v(Lsw1 + Lsw2 + Lsw3) - (V / L)' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -1.54 K DSF8 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.14 K DSF9 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L)' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v ' (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / L) ' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 0.91 K MIN. DRAG STRUT FORCE _ -1.54 K USE: SHEAR WALL NO. 3 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A:B. LSTA36 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 8/12/02 „ Job No. 7912 Page 12 of GARAGE DOOR BEAM - BM1 & BM2 MAXIMUM TRIBUTARY WIDTH (Wtrib) _ MAXIMUM SPAN LENGTH (Lspan) = NorthStar ENGINEERING UNIFORM DEAD LOAD (wDL) = DL * Wtrib = UNIFORM LIVE LOAD (wLL) = LL * Wtrib = WHERE 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 w 13.5 FT 10.5 FT 189 PLF Lspan 216 PLF DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 4X12 DOUGLAS FIR LARCH #1 BEAM AT LIVING ROOM - BM3 w MAXIMUM TRIBUTARY WIDTH (Wtrib) = 12.25 FT MAXIMUM SPAN LENGTH (Lspan) = 14.33 FT 12.25 UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 172 PLF Lspan UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 196 PLF WHERE DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 3 1/8"X>r"24F-V4 GLU-LAM 13'I� BEAM AT FAMILY ROOM - BM4 w MAXIMUM TRIBUTARY WIDTH (Wtrib) = 10.5 FT MAXIMUM SPAN LENGTH (Lspan) = 19.5 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 147 PLF Lspan (, UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 168 PLF WHERE DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 6X14 DOUGLAS FIR LARCH #1 By: MEM NorthStar Date: 8/12/02 ENGINEERING Job No. 7912 Page 13 of BEAM AT PATIO - BM5 MAXIMUM TRIBUTARY WIDTH (Wtrib) _ MAXIMUM SPAN LENGTH (Lspan) _ UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 w 8 FT 17 FT 112 PLF L Lspan UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 128 PLF WHERE DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 6X12 DOUGLAS FIR LARCH #1 BEAM AT ENTRY - BM6 w MAXIMUM TRIBUTARY WIDTH (Wtrib) = 12 FT MAXIMUM SPAN LENGTH (Lspan) = 10 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 168 PLF Lspan 4— UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 192 PLF WHERE DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 4X12 DOUGLAS FIR LARCH #1 NorthStar Engineering 20 Declaration Drive 530-893-1600 Title : Dsgnr: MEM Description : Page 1-4 CIF. Scope Rev: 510001 Timber Beam & Joist Description Timber Member Information Date: Job # 7912 Results Ratio = BM1 & BM2 BM3 BM4 BM5 BM6 Timber Section in -k 4x12 3.125x13.5 6x14 6x12 4x12 Beam Width in 3.500 3.125 5.500 5.500 3.500 Beam Depth in 11.250 13.500 13.500 11.500 11.250 Le: Unbraced Length ft 0.00 0.00 0.00 0.00 0.00 Timber Grade -0.167 'ouglas Fir - Larch, Duglas Fir, 24F - \Oouglas Fir - Larch,Douglas Fir - Larch,Douglas Fir - Larch, Fb - Basic Allow psi 1,350.0 2,400.0 1,350.0 1,350.0 1,350.0 Fv - Basic Allow psi 85.0 165.0 85.0 85.0 85.0 Elastic Modulus ksi 1,600.0 _.1,800.0 1,600.0 1,600.0 1,600.0 Load Duration Factor Shear OK 1.000 1.000 1.000 1.000 1.000 Member Type Sawn Glul-am Sawn Sawn Sawn Repetitive Status 1,433.25 No No No No No Center Span Data 1,638.00 1,088.00 960.00 Max. DL+LL lbs 2,126.25 Span ftl 10.50 14.33 19.50 17.00 10.00 Dead Load #/ft 189.00 287.00 147.00 112.00 168.00 Live Load #/ft 216.00 328.00 168.00 128.00 192.00 Results Ratio = 0.7852 - 0.8315 0.8071 0.6357 0.6583 I Mmax @ Center in -k 66.98 189.43 179.67 104.04 54.00 @ X = ft 5.25 7.16 9.75 8.50 5.00 fb : Actual psi 907.2 1,995.7 1,075.5 858.2 731.4 Fb : Allowable psi 1,485.0 2,400.0 1,332.4 1,350.0 1,485.0 in -0.167 Bending OK Bending OK Bending OK Bending OK Bending OK fv : Actual psi 66.7 132.9 55.1 43.0 56.0 Fv : Allowable psi) 85.0 165.0 85.0 85.0 85.0 Shear OK Shear OK Shear OK Shear OK Shear OK �eactions ' @ Left End DL lbs 992.25 2,056.35 1,433.25 952.00 840.00 LL lbs 1,134.00 2,350.12 1,638.00 1,088.00 960.00 Max. DL+LL lbs 2,126.25 4,406.47 3,071.25 2,040.00 1,800.00 @ Right End DL lbs 992.25 2,056.35 1,433.25 952.00 840.00 LL lbs 1,134.00 2,350.12 1,638.00 1,088.00 960.00 Max. DL+LL lbs 2,126.25 4,406.47 3,071.25 2,040.00 1,800.00 Deflections ' Center DL Defl in -0.078 -0.236 -0.265 -0.189 -0.057 L/Defl Ratio 1,619.7 728.3 882.9 1,081.0 2,109.4 Center LL Defl in -0.089 -0.270 -0.303 -0.216 -0.065 L/Defl Ratio 1,417.3 637.3 772.5 945.9 1,845.8 Center Total Defl in -0.167 -0.506 -0.568 -0.404 -0.122 Location ft 5.250 7.165 9.750 8.500 5.000 L/Defl Ratio 755.9 339.9 412.0 504.5 984.4 February 15, 2003 Lee and Ali Martin 2315 Turntree Ct. Durham, CA 95938 • Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 039-460-083 Building Permit Number: 02-3310 Thank you for resubmitting the plans for your building project. The plans have been reviewed, and the plan examiner's comments are listed below. Please respond in writing to each item by completing and returning the enclosed PLAN REVIEW RESPONSE FORM.. Your complete and clear response will expedite the re -check and approval of this project. STRUCTURAL COMMENTS: 7. Section A: please detail the lateral load path between the Living Room and Porch: Provide a lateral load path from the roof sheathing into the outermost porch beam and into the shear walls at each end. If you wish to discuss any of these requirements, please call (530) 872-2646 between the hours of 9:00 a.m. and 4:00 p.m., Tuesday through Thursday. Please refer to your Data Sheet for remaining non -plane check items. (You received this form when you applied for your permit.) The counter staff will answer any questions concerning the Data Sheet. Keith Long, Architect Plans Examiner Consultant 1 of 1 January 9, 2003 Lee and Ali Martin 2315 Turntree Ct. Durham, CA 95938 Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 039-460-083 Building Permit Number: 02-3310 Thank you for submitting the plans for your building project. The plans have been reviewed, and the plan examiner's comments are listed below. Please respond in writing to each item by completing and returning the enclosed PLAN REVIEW RESPONSE FORM. Your complete and clear response will expedite the re -check and approval of this project. NON-STRUCTURAL COMMENTS: 1. ' Specify and detail use of 12" a.b. in two -pour footings. 2. Please specify safety glazing at B. #2 and both sides of the entry door. 3. Roof plan: specify maximum span of rafters. Between the Floor Plan and Roof Plan, distinguish between ceiling joists and rafters. 4. Provide combustion air to the fireplace. 5. Require that listed equipment have the listing and installation instructions at the job site for review by the inspector(s). 6. Calculations p. 12 specify DF #1 garage door headers, yet the drawings Notes #1 specifies #2 grade. Please correlate to match the calculations. STRUCTURAL COMMENTS: 1. Show how ceiling framing has been included in roof dead load. 2. Plans were submitted 12/2/02. The applicable code would be 2001 CBC. 3. Shear wall Line 2: verify total wall length of 49'. 4. Shear wall Line 2: please identify L3 = 6'. 5. Shear wall Line A: the panels don't seem to correlate with the Plans. 6. Shear wall Line B: where is the L2=8.5'? 7. Section A: please detail the lateral load path between the Living Room and Porch. If you wish to discuss any of these requirements, please call (530) 872-2646 between the hours of 9:00 a.m. and 4:00 p.m., Tuesday through Thursday. 1 of 2 • Please refer to your Data Sheet for remaining non -plan check items. (You received this form when you applied for your permit.) The counter staff will answer any questions concerning the Data Sheet. t Keith Lo c 'tect Plans Examiner Consultant 2 of 2 o -o j -o 14 5E-1°TIG- APPRO- Butte Cou EavbonmentW iris : __/x1 ENVIRONMENTAL HEALTH S C 2"0 CHICO, CALIFORNIA ' �� 131���� ,qtr . •�--�-P J 9 -6 � 1 �� 8 � 1 ��f — - SDA 186dV N01102S • II . IONIAN f��—N cd I- i 'a0H Zlz9 7 � AGr.:x� I ��� »Qi �x:�, t� .l li �c j i it x ,9/l f .91 @ 9`Z Zi in 0 vxZ XS Vv foe `..... _ f nib r; 19061 Alpft rp ! ,I 1 ZC5 121-' 0; ! oZE T?,18516 t SN [ 63?? I Jti3 172:: IT 2 0/ l/eo January 9, 2003 Lec and Ali Martin 2315 Turntree Ct. Durham, CA 95938 Department of Development Services Building Division 7 County Cenier Drive Orovillc, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 039-460-083 Building Permit Number: 02-3310 Thank you for submitting the plans for your building project. The plans have been reviewed, and the plan examiner's comments are listed below. Please respond in writing to each item by completing and returning the enclosed PLAN REVIEW RESPONSE FORM. Your complete and clear response will expedite the re -check and approval of this project. NON-STRUCTURAL COMMENTS- Specify and detail use of 12" a -b. in two -pour footings. SNT .42 VTG . PTL A ! . \i4( Please specify safety glazing at B. #2 and both sides of the entry door. - St -AT . , VO� Roof plan: specify maximum span of rafters. Between the Floor Plan and Roof Plan, distinguish between ceiling joists and rafters. -SNT.#1 OaT(5#10 4 St1T,*Z ZAZ:'F IJ6Te #tS Provide combustion air to the fireplace. `ANT •# 1 Md -M-411. —'S % dT16G14GD 4pp0 equine listed equipment have the listing and installation instructions at the job site Tagt-&5 , or iiti, ew by the inspector(s). Got,17�AG7a�C,T fk-V%De,- KM' Calculations p. 12 specify DF #1 garage door headers, yet the drawings Notes #1 specifies #2 grade. Please correlate to match the calculations. SH T • # 1 GI•R A�$ 'Gti�Rli STRUCTURAL COMMENTS: — 5e4 ATTA.,,jJgD Com M�tJTc> ,+. ov, Show how ceiling framing has been included in roof dead load. 12'0'6` Plans were submitted 12/2/02. The applicable code would be 2001 CBC. Shear wall Line 2: verify total wall length of 49'. A4' - Shear wall Line 2: please identify L3 = 6'. ,S.'OF Shear wall Line A: the panels don't seem to correlate with the Plans. *444 ' Shear wall Line B: where is the L2=8.5'? QSection A: please detail the lateral load path between the Living Room and Porch. If you wish to discuss any of these requirements, please call (530) 872-2646 between the hours of 9:00 am. aiid 4:00 p.m., Tuesday through Thursday. _; ' _ 1•of2 NorthStar ENGINEERING Civil Engineers • Surveyors 5 Butte County Building Division 7 County Center Drive Oroville, CA 95965 Attention: Martha Christy, Keith Long RE: Parcel Number: -039-460-083 Plan No. 02-3310 This letter is in response to your plan check dated January 9, 2003. We have responded as follows: ,,Y. �* Refer to Page 2 of calculations for ceiling framing weight. Note that both the insulation and the gypsum board have been included in the calculation for the weight of the total roof dead load. .24" Refer to revised Page 1 and Page 2 of calculations for reference to 2001 California Building Code. 28 t The wall length along Line 2 is 46' with an overhang of 1.5' on each side. This adds up to a total wall length of 49' for Line 2. Ar -O- At shear wall Line 2, the length of L3 = 6' is found as follows; Refer to the 2'x4' window, wall length of 2.5', and overhang of 1.5' at the corner of the Master Bedroom. This adds up to 6 feet for L3. Note also that the 4' brace wall panel was removed from this wall line. ,6-.A` Refer to revised calculation pages for Shear Wall Line A. fa s� Refer to 5'x4'-6" window and corner wall approximately 3.5' long at KITCHEN for L2=8.5' length along Line B. ,07 Refer to revised Sheet 2, Section A for shear transfer detail. t, i DOlyE• mom- KC -D Ire 660 f5% - rca VOR jr%-PP- F" Z1�3 End of Reply, Michael Main, PE NorthStar Engineering 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX -893-2113 NorthStar ENGINEERING Civil Engineers • Surveyors February 21, 2003 Butte County Building Department 7 County Center Drive . Oroville, CA 95965 Fax: 538-2140 Attention: Keith Long RE: Permit for Martin Residence Building Permit Number: 02-3310 NorthStar Job Number: 7912 Dear Mr. Long, I have reviewed the plan check comments for the property located at the address above and respond as follows: - 7. See revised "Roof Plan" and "Section A" on sheet 2. This concludes my response at this time. If you have any questions, please contact me at 893-1600 ext: 210. Sincerely, Jeff Richelieu, .PE NorthStar Engineering 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX -893-2113 ML N raorthStar ENGINEERING Civil Engineers • Planners • Surveyors A1-21-03 STRUCTURAL CALCULATIONS PROJECT: Lee and Ali Martin Residence LOCATION: Lot #36, Durham Land Estates #4 Butte County, California JOB NUMBER: 7912 DATE: January 22, 2003 CODES: California Building Code, 2001 Edition A CODE ENFORCEMENT: County of Butte Building Department LOADS: Seismic Zone: 3 Wind Speed: 75 mph Exposure: B (Method 2 used, u.n.o.) II Soil Bearing: 1000 psf (per CBC TABLE 13 -I -A) I NOTES: Are Special Inspections required for Engineering Elements Designed by j NorthStar Engineering? No NorthStar Engineering is not responsible for these calculations unless this sheet is stamped by a registered professional engineer and wet signed with RED or BLUE ink. GENERAL: Any structural or non-structural items that are not specifically addressed in the following calculations and or details are designed by others and are not the responsibility of NorthStar Engineering. Page 1 of .- 40= 0.84 = 0.0158 KSF General Notes: 1. The engineer is responsible for the structural items as noted in the following calculations. Should any changes be made to the design as detailed in these calculations without written approval from the engineer then the engineer assumes no responsibility for the entire structure or portions thereof. 2. All water proofing and flashing (roofs,. foundations, retaining walls, decks, garage floors, etc.) is the responsibility of the contractor or owner. 3. These calculations are based on a completed structure. Should an unfinished structure be subject to loads then the engineer shall be contacted for an interim design or if not, will assume no responsibility. 4. Building sites are assumed to be drained and free of clay or expansive soil. Any other conditions must be brought to the attention of the engineer. 5. These calculations assume stable, undisturbed soils, and level stepped footings. Any other conditions encountered must be brought to the attention of the engineer. 6. All footings shall bear on undisturbed soil with a footing depth below frost line (per local requirements). NorthStar 20 DECLARATION DRIVE ENGINEERING CHICO, CA 95973530-893-1600 BY: J M R 1 /22/03 FAX 530-893-2113 JOB NO: 7912 PG. 2 OF Al -21-03 LATERAL DESIGN BASED ON THE CALIFORNIA BUILDING CODE, 2001 EDITION Al GRAVITY LOADS: ROOF: COMPOSITION SHINGLES 3.0 PSF 1/2" OSB OR PLYWOOD 1.5 PSF FRAMING 3.0 PSF R-30 INSULATION (OPTIONAL) 2.0 PSF 5/8" GYPSUM WALLBOARD 3.2 PSF MISCELLANEOUS 1.3 PSF DEAD LOAD 14.0 PSF LIVE LOAD 16.0 PSF TOTAL LOAD 30.0 PSF LATERAL LOADS: SEISMIC: 2.5 * 0.36 * W = 0.200 W 4.5 WHERE R = 4.5 SOIL PROFILE = Sd FOR STIFF SOIL PROFILE Ca = 0.36 PER UBC TABLE 16 - Q r -max = (V / 2) * 10 / (Iw * V) = 5 / Iw = 5 /18'= 0.27778 p = 2 - 20 / (r -max * (Ab)^0.5) = 2 - 20 / (r -max * 4043^0.5) = 0.87 p= 1.00 E = p " VW = 0.200 W (PER UBC EQ. 30-1) NET FORCE = 0.200 W / 1.4 = 0.143 W WIND: EXPOSURE = B METHOD 2 WIND SPEED = 75 MPH Cq 1.3 DESIGN qs 14.5 PSF. PRESSURE Ce 0-15' = 0.62 Cq*qs*Ce = 0.0117 KSF 15'- 20' _ '0.67 = 0.0126 KSF 20'- 25' = 0.72 = 0.0136 KSF 25'- 30' = 0.76 = 0.0143 KSF 30' .- 40= 0.84 = 0.0158 KSF General Notes: 1. The engineer is responsible for the structural items as noted in the following calculations. Should any changes be made to the design as detailed in these calculations without written approval from the engineer then the engineer assumes no responsibility for the entire structure or portions thereof. 2. All water proofing and flashing (roofs,. foundations, retaining walls, decks, garage floors, etc.) is the responsibility of the contractor or owner. 3. These calculations are based on a completed structure. Should an unfinished structure be subject to loads then the engineer shall be contacted for an interim design or if not, will assume no responsibility. 4. Building sites are assumed to be drained and free of clay or expansive soil. Any other conditions must be brought to the attention of the engineer. 5. These calculations assume stable, undisturbed soils, and level stepped footings. Any other conditions encountered must be brought to the attention of the engineer. 6. All footings shall bear on undisturbed soil with a footing depth below frost line (per local requirements). BY: 32 - DATE: 9 1 -z- JOB NO: -7 9 m PAGE 3 OF ENGINEERING Civil Engineers- Planners o Surveyors 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 - ----------- W 91 L I z i 1 i rL K L 300a J LL (L Ec�j ell W L I z i 1 i K . mg By: MEM Date: 8/12/02 Job No. 7912 Page of LATERAL DESIGN SHEAR WALL LINE 1: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. NorthStar ENGINEERING 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L1 = 1.5 FT Lsw1 = 4 FT L2 = 10.5 FT Lsw2 = 3 FT L3 = 10.83 FT Lsw3 = 4 FT L4 = 1.5 FT Lsw4 = 13.67 FT L5 = 0 FT Lsw5 = 0 FT L6 = 0 FT 47.948 K TRIBUTARY WALL AREA FOR WIND (AREAw) = TOTAL LENGTH OF WALL (L) = 49 FT SHORTEST LENGTH OF SHEAR WALL = 3 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 6.85 K 6.79 K LATERAL FORCE THAT GOVERNS (V) = 6.85 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 2305 FTA 2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 149 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 110 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * (Lwext * Dlwext + Lwint * DLwint) W = 47.948 K TRIBUTARY WALL AREA FOR WIND (AREAw) = 581 FT^2 WIND PRESSURE (P) = 0.0117 KSF By: MEM Date: 8/12/02 Job No. 7912 Page S of SHEAR WALL LINE 1: NorthStar ENGINEERING (CONTINUED) 20 DECLARATION DRIVE CHICO, CALIF=ORNIA 95973 530-893-1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) [Y-7 0.278'KL UPLIFT FORCE (Fuplift) = v * Hwall = 2.50 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.14 K NET UPLIFT FORCE = Fuplift - Fdwn = 2.35 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V / L) * L1 = 0.21 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 0.34 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + �2) _ -1.13 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) _ -0.71 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) _ -2.23 K DSF6 = v' (Lsw1 + Lsw2 + Lsw3) - (V / Q ' (L1 + Lsw1 + L2 + Lsw2, + L3 + Lsw3) _ -1.67 K DSF7 = v ' (Lsw1 + Lsw2 + Lsw3) - (V / L) ' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -1.88 K DSF8 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.00 K DSF9 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 0.34 K MIN. DRAG STRUT FORCE _ -2.23 K USE: SHEAR WALL NO. 2 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 8/12/02 Job No. 7912 Page ( of SHEAR WALL LINE 2: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 L Lsw1 L L2 NorthStar ENGINEERING 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L3 lLsw3 I L4 � Lsw4� L5 LLsw5 L L6 L1 = 1.5 FT Lsw1 = 16 FT L2 = 17.5 FT Lsw2 = 8 FT L3 = 6 FT Lsw3 = 0 FT L4 = 0. FT Lsw4 = 0 FT L5 = 0 FT Lsw5 = 0 FT L6 = 0 FT (Lwext * Dlwext + Lwint * DLwint) W = TRIBUTARY WALL AREA FOR WIND (AREAw) = TOTAL LENGTH OF WALL (L) = 49 FT SHORTEST LENGTH OF SHEAR WALL = 8 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.02 K LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 5.33 K LATERAL FORCE THAT GOVERNS (V) = 6.02 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 1738 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 137 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 176 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB: WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * (Lwext * Dlwext + Lwint * DLwint) W = TRIBUTARY WALL AREA FOR WIND (AREAw) = 42.116 K 456 FTA 2 WIND.PRESSURE (P) = 0.0117 KSF By: MEM Date: 8/12/02 Job No. 7912 Page % of SHEAR WALL LINE 2: NorthStar ENGINEERING (CONTINUED) 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893=1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= 0.251 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 2.26 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.38 K NET UPLIFT FORCE = Fuplift - Fdwn = 1.87 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V / L) * L1 = 0.18 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 1.86 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + 1-2) _ -0.29 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) = 0.74 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) = 0.00 K DSF6 = v ' (Lsw1 + Lsw2 + Lsw3) - (V / L) ' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) = 0.00 K DSF7 = v ' (Lsw1 + Lsw2 + Lsw3) - (V / Q ' (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) = 0.00 K DSF8 = v(Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.00 K DSF9 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v' (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 1.86 K MIN. DRAG STRUT FORCE _ -0.29 K USE: SHEAR WALL NO. 2 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM Date: 1/22/03 Job No. 7912 Page of Al -21-03 SHEAR WALL LINE A: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. L1 LLsw1 L L2 NiorthStar ENGINEERING sw2 � L3 LLsw3 L L4 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L5 LLsw5 L L6 L1 = 1.5 FT Lsw1 = 4 FT L2 = 8 FT Lsw2 = 4 FT 1-3 = 4 FT Lsw3 = 4 FT L4 = 28.67 FT Lsw4 = 3.92 FT Al L5 = 15.17 FT Lsw5 = 3.92 FT L6 = 1.5 FT TOTAL LENGTH OF WALL (L) = 78.68 FT SHORTEST LENGTH OF SHEAR WALL = 4 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.42 K LATERAL WIND FORCE ON WALL (Vw) = AREAw * P = 4.15 K LATERAL FORCE THAT GOVERNS (V) = 6.42 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = 1949 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 156 FT LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 143 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 KSF TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * (Lwext * Dlwext + Lwint * DLwint) W = 44.953 K355 TRIBUTARY WALL AREA FOR WIND (AREAw) = FTA 2 WIND PRESSURE (P) = 0.0117 KSF By: MEM Date: 1/22/03 Job No. 7912 Page of Al -21-03 SHEAR WALL LINE A: NorthStar ENGINEERING (CONTINUED) 20 DECLARATION DRIVE Cl ;ICU, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) v = 0.324 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 2.91 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.19 K NET UPLIFT FORCE = Fuplift - Fdwn = 2.72 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V / L) * L1 = 0.12 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 0.85 K DSF3=v*Lsw1-(V/L)*(Ll +Lsw1 +L2)= 0.19 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) = 1.16 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) = 0.83 K DSF6 = v * (Lsw1 + Lsw2 + Lsw3) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) = 1.80 K DSF7 = v * (Lsw1 + Lsw2 + Lsw3) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -0.54 K DSF8 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.41 K DSF9 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = -0.83 K DSF10 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.12 K MAX. DRAG STRUT FORCE = 1.80 K MIN. DRAG STRUT FORCE _ -0.83 K USE: SHEAR WALL NO. 3 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. MSTC28 STRAP AT ALL TOP PLATE SPLICES By: MEM NorthStar Date: 8/12/02. Job No. 7912 ENGINEERING Page ICJ of SHEAR WALL LINE B: INDICATES LENGTH OF DIAPHRAGM WITHOUT SHEAR PANEL, TYP. 20 DECLARATION DRIVE CHICO, CALIFORNIA 95973 530-893-1600 FAX 530-893-2113 INDICATES SHEAR WALL PANEL SECTION, TYP. L1 = 7.5 FT Lsw1 = 4 FT L2 = 8.5 FT Lsw2 = 4 FT L3 = 26 FT Lsw3 = 4 FT L4. = 17 FT Lsw4 = 6 FT L5 = 1.67 FT Lsw5 = 0 FT L6 = 0 FT DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 TOTAL LENGTH OF WALL (L) = 78.67 FT SHORTEST LENGTH OF SHEAR WALL = 4 FT LATERAL SEISMIC FORCE ON WALL (Vs) = K * W = 6.53 K i LATERAL WIND FORCE ON WALLVw — AREAw P = ( ) — * 3.28 K LATERAL FORCE THAT GOVERNS (V) = 6.53 K SEISMIC GOVERNS WHERE CONSTANT FOR SEISMIC CALCULATIONS (K) = 0.143 TRIBUTARY AREA OF DIAPHRAGM FOR SEISMIC (AREAs) = i 2094 FT^2 DEAD LOAD OF DIAPHRAGM (DL) = 0.014 KSF LENGTH OF TRIBUTARY WALLS EXTERIOR (Lwext) = 138 FT ' LENGTH OF TRIBUTARY WALLS INTERIOR (Lwint) = 143 FT HEIGHT OF TRIBUTARY WALLS (Hwall) = 9 FT DEAD LOAD OF WALLS EXTERIOR (Dlwint) = 0.016 KSF DEAD LOAD OF WALLS INTERIOR (Dlwext) = 0.01 TRIB. WEIGHT OF SHEAR WALL (W) = AREAs * DL + (Hwall / 2) * .KSF (Lwext * Dlwext + Lwint * DLwint) TRIBUTARY WALL AREA FOR WIND (AREAw) = W r f 45.687281 WIND PRESSURE (P) = FT^2 0.0117 KSF By: MEM NorthStar 20 DECLARATION DRIVE Date: 8/12/02 CHICO, CALIFORNIA 95973 Job No. 7912 ENGINEERING 530-893-1600 Page I I of FAX 530-893-2113 SHEAR WALL LINE B: (CONTINUED) LATERAL FORCE PER UNIT LENGTH (v) = V / (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) IV= 0.363 KLF UPLIFT FORCE (Fuplift) = v * Hwall = 3.26 K DOWNWARD FORCE RESISTING UPLIFT (Fdwn) = 2 / 3 * (0'* Lsw1 / 2 * DL + Lsw / 2 * Hwall * Dlwext) Fdwn = 0.19 K NET UPLIFT FORCE = Fuplift - Fdwn = 3.07 K HOLDOWN REQUIRED DRAG STRUT FORCE DSF1 = (V/ L) * L1 = 0.62 K DSF2 = v * Lsw1 - (V / L) * (L1 + Lsw1) = 0.50 K DSF3 = v * Lsw1 - (V / L) * (L1 + Lsw1 + 1-2) _ -0.21 K DSF4 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2) = 0.91 K DSF5 = v * (Lsw1 + Lsw2) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + 1-3) _ -1.25 K DSF6 = v (Lsw1 + Lsw2 + Lsw3) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3) _ -0.13 K DSF7 = v * (Lsw1 + Lsw2 + Lsw3) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4) _ -1.54 K DSF8 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L)•* (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4) DSF8 = 0.14 K DSF9 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4) - (V / L) * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5) DSF9 = 0.00 K DSF10 = v * (Lsw1 + Lsw2 + Lsw3 + Lsw4 + Lsw5) - (V / Q * (L1 + Lsw1 + L2 + Lsw2 + L3 + Lsw3 + L4 + Lsw4 + L5 + Lsw5) DSF10 = 0.00 K MAX. DRAG STRUT FORCE = 0.91 K MIN. DRAG STRUT FORCE _ -1.54'K USE: SHEAR WALL NO. 3 PHD2 HOLDOWN ON 2- 2X WITH SSTB20 A.B. LSTA36 STRAP AT ALL TOP PLATE SPLICES By: MEM NorthStar 20 DECLARATION DRIVE Date: 8/12/02 Job No. 7912 ENGINEERING CHICO, CALIFORNIA 95973 Page of 530-893-1600 FAX 530-893-2113 GARAGE DOOR BEAM - BM1 & BM2 MAXIMUM TRIBUTARYWIDTH (Wtrib) = 13.5 FT w MAXIMUM SPAN LENGTH (Lspan) = 10.5 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 189 PLF Lspan UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 216 PLF WHERE DL= 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 4X12 DOUGLAS FIR LARCH #1 BEAM AT LIVING ROOM - BM3 MAXIMUM TRIBUTARY WIDTH (Wtrib) = 12.25 FT w MAXIMUM SPAN LENGTH (Lspan) = 14.33 FT 12.25 UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 172 PLF Lspan UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 196 PLF WHERE DL= 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 3 1/8"X>Z""24F-V4 GLU-LAM 13'2, BEAM AT FAMILY ROOM - BM4 MAXIMUM TRIBUTARY WIDTH (Wtrib) = 10.5 FT w MAXIMUM SPAN LENGTH (Lspan) = 19.5 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 147 PLF Lspan UNIFORM LIVE LOAD (wLL) = LL *'Wtrib = 168 PLF WHERE DL= 14 PSF LL = 16 PSF DESIGN ANALYSIS: (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 6X14 DOUGLAS FIR LARCH #1 By: MEM NorthStar 20 DECLARATION DRIVE Date: 8/12/02 Job No. 7912 ENGINEERING CHICO, CALIFORNIA 95973 Page 13 of 530-893-1600 FAX 530-893-2113 BEAM AT PATIO - BM5 MAXIMUM TRIBUTARY WIDTH (VVtrib) = 8 FT w MAXIMUM SPAN LENGTH (Lspan) = 17 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib.= 112 PLF� Lspan (, UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 128 PLF WHERE DL = 14 PSF LL 16 PSF DESIGN ANALYSIS (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 6X12 DOUGLAS FIR LARCH #1 BEAM AT ENTRY - BM6 MAXIMUM TRIBUTARY WIDTH (Wtrib) = 12 FT w MAXIMUM SPAN LENGTH (Lspan) = 10 FT UNIFORM DEAD LOAD (wDL) = DL * Wtrib = 168 PLF �— UNIFORM LIVE LOAD (wLL) = LL * Wtrib = 192 PLF Lspan �- WHERE DL = 14 PSF LL = 16 PSF DESIGN ANALYSIS- (SEE COMPUTER SHEET ON PAGES THAT FOLLOW) USE: 4X12 DOUGLAS FIR LARCH #1 NorthStar Engineering 20 Declaration Drive 530-893-1600 Page 1-4 .o F 14 - Rev: 510001 Description Timber Member Information Title : . Dsgnr: MEM Description Scope Timber Beam & Joist LCenter Span Data Span Dead Load Live Load ft 10.50 #/ft 189.00 #/ft 216.00 BM1 & BM2 BM3 BM4 BM5 BM6 Timber Section 0.8071 4x12 3.125x13.5 6x14 6x12 412 Beam Width in 3.500 3.125 5.500 5.500 3.500 Beam Depth in 11.250 13.500 13.500 11.500 11.250 Le: Unbraced Length It 0.00 0.00 0.00 0.00 1,332.4 Tlmbef Grade 1,485.0 ouglas Fir - Larch, ouglas Fir, 24F - \Douglas Fir - Larch,Douglas 00 Fir - Larch,Douglas Fir Larch, Fb - Basic Allow psi 1,350.0 2,400.0 1,350.0 1,350.0 - 1,350.0 Fv - Basic Allow psi 85.0 165.0 85.0 85.0 85.0 Elastic Modulus ksi 1,600.0 1,800.0 1,600.0 1,600:0 1,600.0 Load Duration Factor Shear OK 1.000 1.000 1.000 1.000 1.000 Member Type Sawn Glul-am Sawn Sawn Sawn Repetitive Status 2,056.35 No No 840.00 LL Max. DL+LL lbs lbs 1,134.00 2,350.12 1,638.00 1,088.00 No No No LCenter Span Data Span Dead Load Live Load ft 10.50 #/ft 189.00 #/ft 216.00 14.33 287.00 328.00 19.50 147.00 168.00 17.00 112.00 128.00 10.00 168.00 192.00 LReSUItS Ratio = 0.7852 0.8315 0.8071 0.6357 0.6583 Mmax @ Center in-kl 66.98 189.43 179.67 104.04 54.00 @ X = ft 5.25 7.16 9.75 8.50 5.00 fb : Actual Fb : Allowable psi 907.2 1,995.7 -1,075.5 858.2 731.4 L/Defl Ratio psi 1,485.0 2,400.0 1,332.4 1,350.0 1,485.0 fv : Actual 339.9 Bending OK Bending OK Bending OK Bending OK Bending OK Fv : Allowable psil 66.7 132.9 55.1 43.0 56.0 psi 85.0 l 165.0 85.0 85.0 85.0 I- Shear OK Shear OK Shear OK Shear OK ShearrK OK OK Reactions @ Left End DL lbs992.25 2,056.35 1,433.25 952.00 840.00 LL Max. DL+LL lbs lbs 1,134.00 2,350.12 1,638.00 1,088.00 960.00 2,126.25 4,406.47 3,071.25 2,040.00 1,800.00 @ Right End DL lbs 992.25 2,056.35 1,433.25 952.00 840.00 LL Max. DL+LL lbs lbs 1,134.00 2,126.25 2,350.12' 1,638.00 1,088.00 960.00 4,406.47 3,071.25 2,040.00 1,800.00 --I IVA, lIVI IA tenter DL Defl L/Defl Ratio in -0.078 -0.236 -0.265 -0.189 -0.057 Center LL Defl 1,619.7 728.3 882.9 1,081.0 2,109.4 L/Defl Ratio in -0.089 -0.270 -0.303 -0.216 -0.065 Center Total Defl 1,417.3 in0.167 637.3 772.5 945.9 1,845.8 Location ft -0.506 -0.568 -0.404 0.122 L/Defl Ratio 5.250 7.165 9.750 8.500 5.000 755.9 339.9 412.0 504.5 984.4 Date: Job # 7912 i AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 2002-0058575 Recorded OfficialRecords Count BUTTf E CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 01:45PM 31 -Oct -2002 REC FEE 10.00 COPIES 2.50 MaryR Page 1 of 2 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Date10 -�30- Qa State of California County of ; On /Q - 80- 0 before me, personally appeared )V ` i)n n �► A�,LF personally known to me (or proved to me on the basis of sati�ory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my a d official seal. �-•• ' S. AMBROSE D Signature Seal: COMM. 01295163 NOTARY PUBLIC -CALIFORNIA N Q i . COUNTY OF BUTTE wrimrn, F.xpirse Feb. 24, 2005 W A.P;# 639- LitL6390'i EXHIBIT "A" ALL THAT CERTAIN LAND SITUATE, LYING AND BEING IN THE COUNTY OF BUTTE, STATE OF CALIFORNIA, DESCRIBED AS FOLLOWS: LOT 39 AS SHOWN ON THAT CERTAIN MAPINTITLED, "DURHAM LAND ESTATES, PHASE 4," WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JUNE 18, 2002, IN BOOK 154 OF MAPS, AT PAGE(S) 35, 36 AND 37. AP# 039-460-083-00 SITE PLAN REVIEW APPLICATION PTO Date: 12 - 2- U' 2 AP# C 3-1H L o Permit Number (if applicable) 0 2- 35 10 APPLICANT INFORMATION Parcel Size: , A C Owners Name: lag i t iJ� L� A L- 1 Owners Address: 'Z3 _rU2N3'296 6-T- Dy 2H r4W) 5�3� Telephone No.: X2-1 Situs Address: q3 b 8 LA 205 C C -r • LOT w Proposed Use: Residential IN New Single Family Residential ❑ Single Family Addition ❑ Mobile Home ❑ Residential Accessory ❑ Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other IN Septic ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necessary): ❑ Single Family Remodel ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) ❑ Approved Conditionally Approved ❑ Resolve Problems Prior to Approval Site Plan Stamped Approved By Date �2--i—��— Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: ❑ Snow Load Area: ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) ❑ SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attac end) • Flood Zone: • Flood Panel No.: Q52C9fi Index Date: ❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance ------------------------------------------------------------------------------------------------------------------------------------ ❑ Detached Building Use Form ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: sq�! -1 Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Zoning Code Streets & Hi hways Fire Prevention Subdivision Map Front Go qL— 2,0 qL Side Side Street Rear Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Applicable Development Fees: Standard Fees ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ® Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other -------------------------------------- Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) Amount Formula * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By ❑ Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation:❑ No ❑ Yes Comments: ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 IN Subdivision Map/Parcel Map: - 0 V—N-N� LF�►1JJ�> F—S i PIA Map Date of Recording: 6—)8-o12- Lot: 3 4P ❑ Use Permit/Minor Use Permit Permit Number: Book: 1 S Date of Approval: Page: -�, s 3 Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel ' ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ` ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. ❑■ Page 4 of 5 r r� NOTF'S 1. 11-11S SHEET SHOWS ADDITIONAL INFORMATION. IS FOR ADDITIONAL INFORMATION PURPOSES ONLY. DESCRIBING CONDITIONS AT THE TIME OF FILING AND IS NOT INTENDED TO AFFECT RECORD TITLE INTEREST. 2. A SOLID FENCE CHAIN LINK. BRICK. BLOCK OR SIMILAR MATERIAL. NOT WOOD. A MINIMUM OF SIX FEET IN HEIGHT SHALL BE INSTALLED ALONG THE SOUTHERN AND WESTERN PROPERTY LINES OF THE PROJECT. PRIOR TO ISSUANCE OF BUILDING PERMITS FOR ANY RESIDENCE IN PHASE 4. 3. DEVELOPMENT OF ALL LOTS IN THIS SUBDIVISION WILL REQUIRE CONNECTION TO A PUBLIC WATER SUPPLY. 4. SHOULD ANY ARCHAEOLOGICAL OR CULTURAL MATERIALS BE ENCOUNTERED DURING PROJECT CONSTRUCTION, SITE DEVELOPMENT SHALL CEASE AND ARCHAEOLOGICAL CONSULTATION SHALL BE IMMEDIATELY RETAINED. 5. ALL ALMOND TREES SHALL BE REMOVED FROM THE PROPERTY. REMOVAL OF TREES CAN FOLLOW THE PROPOSED PHASING PLAN SHOULD ACTIVE FARMING CONTINUE AS THE PROJECTAS IS DEVELOPED. 6. A DEVELOPMENT IMPACT FEE FOR SHERIFF'S FACILITIES SHALL BE PAID PURSUANT TO THE PROVISIONS OF CHAPTER 3. ARTICLE N OF THE BUTTE COUNTY CODE, PRIOR TO ISSUANCE OF BUILDING PERMITS OR USE PERMIT IN THE CASE OF A MOBILE HOME PARK. SAID FEE AMOUNT WILL BE DETERMINED AND CALCULATED AS OF THE DATE OF APPLICATION FOR THE BUILDING PERMIT OR USE PERMIT. 7. ALL OAK TREES ON THE PROPERTY SHALL BE PRESERVED EXCEPT FOR THOSE REOUtRED FOR ROADS, DRIVEWAYS, OR BUILDINGS. A NO DISTURBANCE SETBACK SHALL BE PROVIDED COMMENCING FROM THE OUTER EDGE OF THE OAK TREE CANOPY. 5'-I - 35 3 7 ADDITIONAL INFORMATION SHEET DURHAM LAND ES,- rA TSS PHASE 4 A PU X S Scar WSKN $ESN ,* A PORTION OF 17-il REMAINING LANCES Of 0URHAM. LANG ESTATES PHASI ' I ROOK Of OF W M PAC 71-74, ALSO BEING A POR17ON OF 774E SOUINEA-S-r 11-4 OF SEC17ON 25., TOWNSHIP 21 NORM, ?ANG 1 EAS' ' AN17 A POR770N OR P 8OLnNW114 OP SEC77ON 20, T'OWUS life' AfOR7►~t=� _. `._ r � Y � VI