Loading...
HomeMy WebLinkAbout040-215-0090 40-215-9 - - = — -• - -_ ...��� _ ---_- _ _ _ - � q John Clark I 2362 Durham St., Du$am n� / ontr : Chico Elec . , Chico Permit #3900-81E(new elec.serv./SF) 40-215-09 STEVE GRAVES 2362 Durham St, Durham eTm t#28L6-88B E-(new'"garage) 040-21-5-009 91-3766 GRAVES, STEVEN, VANESSA CONTR: LYM ELECTRIC 2362 DURHAM ST, DURHAM UNDRGRND ELEC/SF B07-2303 040-215-009 MISCELLANEOUS Room Addn-First Stry CARPORT TO LIVING 530_SQ.FT. 2362 DURHAM ST GONZALEZ, FELIX APPROVED ��1 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 WEBSITE: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 2362 DURHAM ST Owner: Permit No: B07-2303 APN: 040-215-009 GONZALEZ, FELIX Issued Date: 1/16/2008 By GLB Permit type: MISCELLANEOUS 2362 DURHAM ST Subtype: Room Addn-First Stry DURHAM, CA 95938 Expiration Date: 1/15/2009 Description: CARPORT TO LIVING 530 SQ.FT. (530) 899-7453 Occupancy: Zoning: R3 Contractor Applicant: Square Footage: GONZALEZ, FELIX GONZALEZ, FELIX Building Garage Remdl/Addn 2362 DURHAM ST 2362 DURHAM ST 530 DURHAM, CA 95938 DURHAM, CA 95938 (530)'899-7453 (530)899-7453 Other Porch/Patio Total 530 FEE INFORMATION DBEH Building Review Fee $75.70 DBF Room Addition - First Stor $186.77 DBF Room Addition - First Stor $186.37 DBMSC Room Add -1st Story 250sf $279.55 DBMSC Room Add -1st Story 250sf $280.15 DBSMIP Residential $2.95 DBSMIP Residential $0.50 Tota] Charged: $1,011.99 Fees Paid: $1,011.99 Balance Due: $0.00 Receipt No: B6109 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License GONZALEZ, FELIX / / Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) is in full force and effect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the X1/16/2008 basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil of not more than five hundred dollars penalty [$500]; Please check one of the following: Contractors Signature Date • ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of the property, who builds or improves thereon, and who does WORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: HAVE AND the work himself or herself or through his or her own employees, provided that such improvements ❑I WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). I HAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by ❑❑ Section 3700 I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Provessions Code: of the Labor Code, for the performance of the work for which this permit is issued. My Workers' Compensation insurance carrier and policy number are; The Contractor's License Law dows not apply to an owner of the property who builds or improves thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Contractors License Law.). Cartier: Policy Number: Exp. Date: (This section need not a competed if the permit is or one hundred dollars ($100) or less. ❑ I AM EXEMPT under Section B. 8 P.C. for this reason: ❑I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California, and agree that if I should become subject to the workers'X 1/16/2008 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those O nets Signature Date provisions. 1/16/2008 1 hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and Slate laws relating to building ' SI nature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CML FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, injury, including death, and property damage caused arising out of, in any way connected with DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND the issuance of this permit. I hereby acknowledge thatt is issuance of this pea rmit does not authorize the use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. County to enter the above mentioned property for inspection purposes. I hereby certify that I am the propor authorized to on the propert ers behalf. CONSTRUCTION LENDING AGENCY 1/16/2008 I HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Aame of Permittee [SIGN] Print Date the performance of the work for which this permit is issued. (3097 civ. code) Owner 1:1 Contractor OR. Agent for Owner ❑Agent for Contractor FILE COPY Lenders Address City State zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OF APPLICATION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" OWNER INFORMATION Last Name Gn =41Z First Name , Mailing Addys., U City State C� Zip Phone O _ Fax E-mail APPLICANT =NATURE X � PERMIT NO.. BIN # PROJECT LOCATION AP# 04-0 — '0 05 — 00 Property Address o? 3(o City r ,, (I?—" WORKER'S COMPENSATION Policy Number `Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: AA �e r Sq FT- Living 3() arage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: - CONTRACTOR Name Ow�t Address Ur CityZ�jState State Zip Phone O _ Fax E-mail Lic. # Class APPLICANT =NATURE X � PERMIT NO.. BIN # PROJECT LOCATION AP# 04-0 — '0 05 — 00 Property Address o? 3(o City r ,, (I?—" WORKER'S COMPENSATION Policy Number `Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: AA �e r Sq FT- Living 3() arage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: - ARCHITECT/ENG/NEER Name 0 W Address ekw e City State Zip Phone Fax E-mail State License Number APPLICANT =NATURE X � PERMIT NO.. BIN # PROJECT LOCATION AP# 04-0 — '0 05 — 00 Property Address o? 3(o City r ,, (I?—" WORKER'S COMPENSATION Policy Number `Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: AA �e r Sq FT- Living 3() arage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: - APPLICANT INFORMATION Name 0 W Address ekw e City State Zip Phone Fax E-mail APPLICANT =NATURE X � PERMIT NO.. BIN # PROJECT LOCATION AP# 04-0 — '0 05 — 00 Property Address o? 3(o City r ,, (I?—" WORKER'S COMPENSATION Policy Number `Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: AA �e r Sq FT- Living 3() arage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: - Zoning `;3 I Flood Zone ISRAI res No 0cc. Type Const. Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds PERMIT APPLICATION DATA SHEET Reference Number: B07-2303 Date: 11/09/2007 Location: 2362 DURHAM ST By: TMP Parcel Number: 040-215-009 Sub Type: Room Addn-First Str Owner Name: GONZALEZ, FELIX Phone: (530) 899-7453 Description: CARPORT TO LIVING 530 SO.FT. The above permit application has the following Clearances required prior to permit issuance. Please contact each department indicated below regarding specific requirements pertaining to your permit application. Yes No DRAINAGE DISTRICTS ❑ ❑ Thermalito Irrigation District, 410 Grand Avenue, Oroville CA 95965 - (530) 533-0740 ❑ ❑ LOAPUD, 1960 Elgin Street, Oroville CA 95966 - (530) 533-2000 ❑ ❑ City of Chico, 545 Vallombrosa, Chico CA 95926 - (530) 895-4711 PARKS & RECREATION DISTRICTS ❑ ❑ Chico Area Recreation District, 545 Vallombrosa, Chico CA 95926 - (530) 895-4711 ❑ Durham Park & Recreation District, 9447 Midway, Durham CA 95938 - (530) 345-1921 ❑ ❑ Feather River Recreaction & Park District, 1200 Myers Street, Oroville CA 95966 - (530) 533-2011 ❑ ❑ Paradise Parks & Recreation, 6626 Skyway, Paradise CA 95969 - (530) 872-6393 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ SCHOOL DISTRICTS Biggs Unified School District, 300 B Street, Biggs CA 95917 - (530) 868-1281 Chico Unified School District, 1163 East 7th Street, Chico CA 95926 - (530) 891-3006 Durham Unified School District, 4920 Putney Drive, Durham CA 95938 - (530) 895-4675 Gridley School District, 429 Magnolia, Gridley CA 95948 - (530) 846-4723 Marysville School District, 1919 B Street, Marysville CA 95901 - (530) 741-6000 Oroville Elementary School District, 2795 Yard Street, Oroville CA 95966 - (530) 532-3000 Oroville Union High, 2211 Washington Ave, Oroville CA 95966 - (530) 538-2300 Ext:105 Paradise Unified School District, 6696 Clark Road, Paradise CA 95969 - (530) 872-6400 OTHER Recorded copy of Agricultural Acknowledgment Statement- See Attached Instructions City of Biggs Planning Department, 3016 Sixth Street Biggs CA 95917 - (530) 868-5447 Other: Other: Other: Signature of Property Owner: A�FDate: 11/09/2007 APPLICANT Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds OWNER -BUILDER INFORMATION An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit. Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that you plan to subcontract, you should be aware of the following information for your benefit and protection: ° If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $500 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. ° If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal ° income tax withholding, federal social security taxes, workers/ compensation insurance, disability insurance costs, and unemployment compensation contributions. There may be financial risks to you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. ° For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or through thier own employees, without a license contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractor is to secure an "owner -builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board's automated telephone information system at 1-800-321 -CLSB (2752) or by accessing thier website at www.CSLB.ca.gov. PLEASE COMPLETE AND RETURN THE ENCLOSED OWNER -BUILDER VERIFICATION FORM SO THAT WE CAN CONFIRM THAT YOU ARE AWARE OF THESE MATTERS. THE BUILDING PERMIT WILL NOT BE ISSUED UNTILL THE VERIFICATION IS RETURNED. OWNER BUILDER VERIFICATION PLEASE COMPLETE THIS FORM AS REQUIRED BY THE STATE OF CALIFORNIA (SENATE BILL NO. 831 EFFECTIVE JULY 1, 1980). NO BUILDING PERMIT WILL BE ISSUED7oRPNO)THIS VERIFICATION IS RECEIVED. 1. I PERSONALLY PLANROVIDE THE MAJOR LABOR AND MATERIALS FOR CONSTRUCTION OF THE PROPOSED PROPERTY IMPROVEMENT. (YE 2. (HAV VE NOT) SIGNED AN APPLICATION FOR A BUILDING PERMIT FOR THE PROPOSED WORK. 3. I HAVE CONTRACTED WITH THE FOLLOWING PERSON (FIRM) TO PROVIDE THE PROPOSED CONSTRUCTION: NAME ADDRESS CITY PHONE CONTRACTORS LICENSE NO 4. I PLAN TO PROVIDE PORTIONS OF THE WORK, BUT I HAVE HIRED THE FOLLOWING PERSON TO COORDINATE, SUPERVISE, AND PROVIDE THE MAJOR WORK: ADDRESS CITY PHONE CONTRACTORS LICENSE NO 5. I WILL PROVIDE SOME OF THE WORK BUT I HAVE CONTRACTED (HIRED) THE FOLLOWING PERSONS TO PROVIDE THE WORK INDICATED: NAME ADDRESS PHONE TYPE OF WORK Description: CARPORT TO LIVING 530 SQ.FT. Reference Number: B07-2303 Applicant Name: GONZALEZ, FELIX Owner's Name: GONZALEZ, FELI /� AP h Signature of Property Owner: G� Date: 040-215-009 Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds NOTICE TO BUILDERS Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things you can do to expedite your permit: 0 Make sure your application is complete. 0 Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit. A permit may be renewed (for a fee) prior to expiration an indefinite number of times, provided construction progress has been documented by the Building Division during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications (not yet issued) must be requested within two years from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge of $54.99 to process the refund application will be assessed. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at http://municit)alcodes.lexisnexis.com/codes/butteco/ Reference Number: B07-2303 Location: 2362 DURHAM ST Parcel Number: 040-215-009 Owner Name: GONZALEZ, FELIX Description: CARPORT TO LIVING 530 SQ.FT. Date: 11/09/2007 Phone: (530) 899-7453 Signature of Applicant: Date: 11/09/2007 FILE BUTTE COUNTY DEVELOPMENT FEE CERTIFICATION FORM ❑ FEATHER RIVER RECREATION AND PARK DISTRICT (FRRPD) ❑ CHICO AREA RECREATION AND PARI{ DISTRICT (CARD) ❑ P RADISE RECREATION AND PARK DISTRICT (PRPD) UR.HAM RECREATION AND PARI{ DISTRICT (DRPD) Assessor Parcel Number (s)� J /S Q�� Building Permit Number $Q 7- Property Owner (s) Project Location /P Subdivision Name New Development teration/ ddition(s) Mobile home Assessable Sq. Ftge Q3 O Type of Residential Development (check one) . Demo Permit (date issued Comments: Single Family -Detached Non -Residential to Residential Mobile home replacement _ Single Family -Attached _ Multi -Family Dwelling. _ verified by Assessor Department verified by Building Department ❑ FRRPD ❑ CARD ❑ PRPD RPD certifies that: Applicant Name Phone Number 'a3G9- urkam C A M2 Mailing Address City State Zip Has complied with requirements of the Butte County Board of Supervisors Resolution No. o J7— 16-6 by Payment of: Dwelling Units @ $ per unit for a total of $ S30 Square Feet @ $ a 3 s per sq foot for a total of Remarks: Paid by Check No: /go/ Paid by Cash: and Park District Representative Recei pt No: 93 Date BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) School District L)IAI-Iryl S(V CCL, i 1 1-4. Building Department No. Tax Rate Area No. A.P. Number ���"'G� Jurisdiction: = City County Property Owner T P If y Property Location/Address / . �— Subdivision Residential Development Q Q No of Living Mobile Home Units Installation Commercial/Industrial Q ,Nbw Addition Lot No. ................................................................................................... © Sq. Footage Addition/ 'Supplemental to (Group R) Conversion Permit # Cr. Demo - ( ) "(No foundation inspection) existing sq. ft. see attached ............. _................................................................................... Net total sq. ft. Deed Restricted Sq. Footage (Attach a signed copy of Deed Restriction and Notice of Limited Use Facility document) District Identification No. - /0 3 & ✓`� /—/670 School District certifies that a 3C,, (Street Address) Sq. Footage ' (Including Exterior Roofed Areas) 1-67-102 . Date (Payor) ittre- r 959.38 (City) (Zip Code) f i 9- 74/5 3 (Phone Number) has complied with the requirements of Resolution No. d 6e by payment of $ / 3 93. Qd representing square feet. JAB 2926 $ ' FULL MIT)GATION $ School District Representative t y / �DD.rre� Paid b Check # � Remarks: Date /—/0- b R - Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (school district), Yellow (building department), Pink (applicant) feeform.xls (12/06)dmm 1 PLAN REVIEW RESPONSE FORM In order to expedite the review of your plans, please complete the following information and return this form with your re -submittal. this form is not complete, as to all correction items, we will not be able to accept your re -submittal for review. There must be a VZ response to every item requested in our plan correction letter. `By others'' is not considered a valid response. Please indicate y. response to each item and the location where the information can be found on the plans/calcs. ATTACH THIS FORM TO A COPY OF YOUR PLAN REVIEW LETTER AND RETURN WrM RMSED AND ORIGINAL PLANS. OWNERS NAME DATE: ASSESSORS PARCEL NUMBER PERMIT NUMBER RESPONSE FOR PLAN HECK LETTER DATED: IQ 1'-4 ;© , , PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANSICALCS: � A coMMENTs 1 Q.eu.e3a las CAQ.A— '&D&l ''til. � ro QIr -i< L.A,0S PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CAWS: COMMENTS: ' �N(o Oc.sN 6a i Zj . %�Q�t1 a CLe� EYT► P((o S _IZ Q3 S 12" 1.-> t0C PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANSICALCS: -7( - COMMENTS: A,i- dF �N(o Oc.sN 6a i Zj . %�Q�t1 a CLe� EYT► P((o S _IZ Q3 S 12" 1.-> t0C I N f' F`Z S 0 i,.r t� S "4CD . COMMENTS: "jgl.cr 4PtCZS-> Nlftet� PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALLS: M . �,/� Az: 4 7 (pew () .4 , COMMENTS: "jgl.cr 4PtCZS-> Nlftet� Of''c_ i. Z4-C.0WA-t. P%t-ls}—. Ao QE -Cs —1-t� D=&t t_ 4 1 6,.j SrtT PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANSICALCS: COMMENTS �'�� �¢n.ori �-T 1-Y'�u►.�TCr.iO,.tt-,r- . 1 • L40 A16-rQD e:xj S -V. &A I Z /l -T e11zM-A-4(=6 Ni & PLAN REVIEW RESPONSE FORM � In order to mTedite'the review of your plans please complete the following information and retmn this form:with your re -submit this form is not complete, as to all correction items, we will not be able to accept your m-submitial for review. 'Dere must be a response to every idem requested in our plan correction letter. `By other? is not considered_ a valid response, please indicate response to each item and the location where the information can be found on the plans/calcs. ATTACH THIS FORM TO A COPY OF YOUR PLAN PmEw LETTER AND RETURN wrlli'REVISED AND ORIGINAL. PLAN OWNERS NAME DATE, /� !/Y- 12, /17jo-7 ASSESSORS PARCEL NUMBER . PERMIT NUMBER c)69 8-7 RESPONSE FOR PLAN HECK LETTER DATED: rutin %mma.. a i tai i KtZrUNSh BY'. LOCATION ON PLANSICALCS: COMMENTS, s i t✓`� --� t`J so—r- •-to i u O'!L 4.A ver tZTI tJ - M G w p 1 iv ' ` tf-rh I ►—� PLAN CtLECK fr"M # RESPONSE BY: COMMENTS: LOCATION ON Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE"CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile December 4, 2007 Felix Gonalez 2362 Durham St. - Durham, CA 95938 www.buttegeneralplan.net www.buttecou nty. netidds ADMINISTRATION " BUILDING' PLANNING Assessor Parcel Number: 040-215-009 Building Permit Number: 07-2303 Thank you for submitting the plans for your building project. The plans have been reviewed and comments are listed below. Please respond in writing to each item by letter or by completing and returning a Plan Review Response Form. Your complete and clear response will expedite the re -check and approval of this project. Plan Review comments: 1. The portion of your home in which your conversion is purposed was built without permits and inspections. A permit was applied for, but the inspection record indicates no work was ever started. The permit was filed on September 20, 1989, stating no work done. The purposed conversion at this e is considered an addition. The portion of the structure built without permits and inspections ust comply with the 2001 edition California BuildingCode requirements. Note on the plans: For all PEX or CPVC installations, a completed "REQUEST TO USE PEX WATER PIPE" or "Certificate of Compliance for installations of CPVC Plumbing Materials" form must be submitted and approved by the Building Official. 3. Please indicate complete framing details for roof construction and provide beams and footing sized to acc mmodate loads. 4.,1- ovide a braced wall panel schedule for this plan. erify Roof beams in purposed garage area. The beams shown on page A2 do not match the beams /§hown in the section on page A5. 6/ Show complete building on submitted pans. The storage area is not shown completely and is also d' ted as being built without a building permit or required inspections. Wall framing details, braced wall information, foundation detail and roof framing plan will be required. Provide 2 copies of revised plans to this office so plan checking may continue on this application. If you wish to discuss any of these requirements, please call (530) 538-7541 between the hours of 1:00 p.m. and 4:00 p.m., Monday through Friday. Please refer to your Data Sheet for remaining non -plan check items. (You received this form when you applied for your permit.) The counter staff will answer any questions concerning the Data Sheet. / 1 - Carl Nelson Plans examiner 1 PERMIT NO. 2826-88B, E PERMIT EXPIRES i3 10 OWNER STEVE RAVES CONTR. owner ASSESSOR PARCEL 407215-09 LOCATION 2362 Durham St,Durham �� 0 Temp. Power Pole Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Service r r Called PG&E JOB FINALED (Date) Signature = OK 0 --:"Not OK, Not ' = Not Ready MOBILE MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. Y /"Nat. or/ /"L"ft./ /"LPG 7. Utility Clearance Card -B1 Date Card -61 Date Card -B1 Date Card -131 Date Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy. Card -81 Date Card -131 Date Card -131 Date Card -B1 Date MISCELLANEOUS Date DECKS, COVERS,CARPORTS,GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms-Rftrs.-Connec.- Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Elec. 8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Card -131 Date Card -B1 Date Card -61 Date Card -131 Date Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness - Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures;`Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.;Grounding; Equip. w/5' -circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Card -131 Date Card -131 Date Card -131 Date Card -131 Date r- 1 = OK 0 = NotOK RESIDENTIAL (Single and Duplex) - =Not Applicable = Not Ready Date UNDERFLOOR (Plans) OK except #'s -r Date FRAMING (Continued) rT 1. Zoning -Setbacks; -Easements -Flood -Slope 45. Hangers -Post Caps -Anchors -Connectors 2. Ftg., Main; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 46. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng. 3. Ftg., Garage; Soils -Steel-/ P' Ftg. Depth 47. Fireplace Ties or Type A Flue -Fireplace Throat Clearance _ 4. Ftg., Porches & Decks; Soils -Steel-/ /"Ftg. Depth 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 5. Stemwalls, Main; Steel- Blockouts-Wrapped 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 50. Garage Fire Protection Framing 7. Slab; Steel -Wrapped 51. Property Line Firewall & Openings 8. Piers -Fireplace Ftg.-Steel 52. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 9. D.W.V.; Fall -Fittings -Test -2 way C/O -Sewer Test 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 10. Gas Pipe; Size -Anchors 54. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 11. Water Pipe; Test -Anchors -Regulator -Service Test 55. Siding -Nailing Veneer 12. Electric; Underground 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 13. Plenums & Ducts; Clearance-Material-Supprt-Ins. 57. Glazing Area -Glass Protection -Skylights -Plastic 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 58. Shear Walls; Nailing -Bolts 15. Insulation 59. Insulation-Walls-Clg. 60. Infiltration-Walls-Wndws Card -131 Date Card -131 Date Card -131 Date Card -131 Date Card -B1 Date Card -B1 Date Card -131 Date Card -B1 Date Date PLUMBING (Permit) OK except #'s 16. Water Ht. Vent -Access -Combustion Air -Baffle Date FINAL (Plans) OK except #'s 17. Water Pipe; Test & Anchors -Nail Protection 61. Ext. Steps -Door & Sidelight Protection -Landings 18. D.W.V.; Test-Fttngs & Anchors -Nail Protection 62. Smoke Detector 19. Shower Pan; Test, First Floor -Tub Access 63. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Meeh. Protection 20. Test Tub & Shower, 2nd Floor -Tub Access 21. Gas Pipe; Size & Anchors 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes -Labels Card -61 Date Card -B1 Date 67. Stairs &Rails Card -B1 Date Card -131 Date 68. Fireplace or Stove; Clearances -Hearth 69. Elec. Outlets at Wood Panel; Int. & Ext. Date ELECTRICAL (Permit) OK except #'s e 22. Fixture & Transformer Clearance -Ins. Protection 70. Kit. Fixt. & Appliance; Grnd. -Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter 23. Elec. Receptacles Spacing -Lights & Switches at Doors 72. Garage Fire Door; Swing -Landing -Closer r 24. Size Boxes & No. of Conductors -Stapled 73. A.C. Duct in Garage -Damper 25. Romex Installed Close to Edge of Studs & C.J. 26. Equip. Ground made up w/Meeh. Fasteners -Bond Gas & Water 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 27. 2 Appliance Circuts in Kitchen &Conductor Size/G.F.I. 75. Plb., Elec. & Mech. Equip. Listed for Location 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / /ga. Cu or Al 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral Yes No 77. Insulation -Foam -Looked in Attic ❑ Yes 78. Guard Rails & Deck Construction -Post Caps 30. Service -Riser Conductors & Ground -Main Disconnect 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 31. Equip. Clearances Panels-Motors-Mech. Equip. 80. Following instid.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector 81. Stucco; Brown -Finish Card -131 Date Card -61 Date 82. A.C. Unit; Disconnect, Electrical, Plumbing Card -B1 Date Card -131 Date 83. Vents Above Roof; Pibg.-Appliance-Firepl.-Clearance to Openings. Date MECHANICAL (Permit) OK except #'s 84. Water Well; Disconnect, Electrical, Plumbing 34. A.C. Ducts Insulation & Support 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 35. Vent Fan; Exhaust above insulation 86. Ventilation throughout House 36. Condensate Drain & Overflow; Size & Grade 87. Glass Protection 37. Furnace -Vent; Access -Comb. Air -Return Air Vent -115 outlet 88. Corrections from Previous Inpections 38. Attic Access & Platform if Furnace in Attic 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Card -81 Date Card -81 Date 92. Roofing Certificate Card -B1 Date Card -B1 Date Card -131 Date Card -131 Date Card -131 Date Card -131 Date Date FRAMING (Plans) OK except #'s 39. Sills, Proper Material & Anchors Card -B1 Date Card -131 Date 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound Comments at Final: 41. Bearing Walls over Girders & Floor Nailing 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Header & Beam -Size & Bearing (NOTE: An entry must be made each time you visit job site) J _ COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville. California 95965 - Telephone: 916/538-7541 APPLICATION AND -PERMIT PERMIT N0 ASSESSORP RCEL NUMBER �... — �® a ZONING BUILDING PERMIT OWNER t ��T TELEPHONE SQ. FT. OCC. BUILDING VALU ION OWNER'S MAILING ADDR S CONTRACTOR'AME TELEPHONE C TRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ a o ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee .$ SE Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ '1 PLUMBING PERMIT Filing Fee 10.00 AM 7 215 , Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each pas water heater or vent 5.00 / USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 % Building sewer 5.00 % Mob le Home Is G W 0.00 ea TYPE OF WORK ' Newx Addition ❑ Remodel ❑ Utilities ❑ Installation[] Other ❑ Describe work: -2 Permit Fee $ Contractor Contractor ELECTRICAL PERMIT FiIin9 Fee 10.00 SAW Main service eoov OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 TRACTORS LICENSE LAW I declare under pen l o p(check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- Y'sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCU OR ADDNS. ( ACC. BLDGS. yz2sq ft rR Perjury NEW CONSTR TI.OUTLET 2.50 ea NON-RESID BRANCH CIRC 1 S POWER APPARATUS &) (SINGLE OUTLET CIR. EX. OCCUp(OUTLETS OR FIXTURES .200030 FIXED APPLNS. OR EX. Occup. OUTLETS (RESID.) EA.) 1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. �Yirin 15.00 9 Permit Fee $ a , KMEN'S COMPENSATION INSURANCE I declare undeFptnaity of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement,should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 10.Q0 Heating Cooling Hood 3.00 Ventilation Permit Fee ; Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, an penses which may in any way accrue against said C,pdnty in cons eque he granting of this permit. ...' X Date Signature of Applicant — Own.r Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ _ TOTAL PE MIT FEE $ o OP. �, CONS .T E V SCHOOL FVDJ PARCEL PD HD Is3u his permit is hereby issued under sions of the Butte County Code and/or work indicated above for which 211EC R O PUBLIC BY PERMIT EXPIRES Date the applicable resolutions to do to do fees have been paid. WORKS &V/., Date r3 5 " Receipt No. 01 / J �' a--- WHITE-D.P.W., YELLOW-A3e9330R. PINK -INSPECTOR. GOLDENROD -APPLICANT '.�.`."-.��z.+..-.,__..ry--•� ..z.....-.+p.:eM. r'w A- --Irgrnf+'„77IFL«'.��(9"`flel�h COUNTY OF BUTTE -'DEPARTMENT-OF UBLIC WORKS - BUILDING DIVISION 7 COUNTY CENTER DRI;{E - OROVILLE, OAUFORMA 95965 -TELEPHONE: 916/538-7541 Ij PERMIT,APPLICATION DATA SHEET Permit No. OWNER 5t"Coue �. �f'o•veS A. P. No. V0- al- -5 Proposed Building Use Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and:/or issuance: DATE RECEIVED APPROVED 1. All items.have been submitted. . . . . . . . . . . 2. Plot plans in duplicate. /triplicate, signed by preparer of plans. . 3. Complete plans in duplicate./triplicate, signed by preparer of plans. 4. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. . . . . . 6. School District "Fees Paid" Stamp on Floor Plan. 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ , , , , , , , 9. Letter of signature authorization( 10. Sanitation approval from Health Dept. 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. . . . . . 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to owner0, Mail to ownerE]) _15. Improvements may be required. . . . . . . . . . . . 16. Mobi lehome Installation Data. . . . . . . . . . Prednspec. request to (Date) 17. Pre -Inspection for Required. guilding Inspector , 18. Recorded copy of Agricultural Acknowledgment Statement. f 19. Driveway Permi,b, 20. Plot plan approval from city of 21. Engineered trusses'in duplicate (required prior to plan check)._, 22. ,eS When you issue the permit, process as follows: Mail to owner, Mail to contractor. Telephone and hold for pickup at office, Deliver w/inspector. Other_ .00* Applica-Date ^��o Copy of plans sent Health Dept., Fire Dept., Other Date The following data must be submitted 1. Index permit for above items No. - 2. o._2. Additional items required: ipr tom permit issuance: (Circle new item not checked above). Contractor, designer, n wwas advised of above required data by phone�nall_counter by 169- date Contractor, designer, er, was advised of above required data by—phone _mall—counter by date Plans checked by Date Plans approved byDate A Sets of plans on hold in File cabinet AP folder Copy—DPW TO Building Department ..�,,. FROM: Environmental Health SUBJECT: Sanitation Clearance QVIRVISMA Plan Approved for:. Sewage Disposal Water Supply Hold final for: Water Supply Final clearance O.K. for: Water Supply Clearance for bedroom mobile home. 'Other C, NOTE * * * COUNTY OF BUTTE - Department of Public Works 7 County Center Drive, Oroville, CA 95965 Phone: 916-538-7541 OWNER -BUILDER VERIFICATION Attention Property Owner: An 'owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed pro pert improvement (yes or no) 2. -I (have/have not) signed an application for a building permit for the proposed work 3. 1 -have contracted'with the following person (firm) to provide the proposed construction: Name Address City Phone Contractors License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractors License No. 5. I.will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: Property Owner S/�� Social Security Number - Date �'— / — NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to -our office before we are per- mitted to issue the permit. C f r i t' 1, t Y �=)..l ' \L.� • T# ! k �. r . ) too: 60.4PARED WVTH OR161NA1`D6COM.64T L ea AP NOTICE OF CONSTRUCTION > AFFECTING ADJOINING PROPERTY The undersigned, /; %�; ` �j /9 (% jS do hereby declare as follows: 1. I am, (rare), the. -owners) of that certain•real property situated in the County of Butte, State of California, described in attached Exhibit A. 2. I, (1p), intend to apply to the County of Butte for a building permit and, pursuant to said permit, to construct improvements on the said property. I, itt), do hereby place all subsequent purchasers and encumbrancers on notice that such improvements will be constructed over a parcel or lot line(s) as described in the above noted Exhibit A, and that subsequent purchasers and encumbrancers should be aware of the location of such improvements. 3. So long as such improvements remain, said parcels or lots cannot be sold separately.. ; DATED • 'Signature of owner of record STATE OF CALIFORNIA ss. COUNTY OF BUTTE i� Signature of owner of record STEVEN GRAVES On SEPMMER 7 , 19_&L_,tbefore me, the undersigned, A Notary Public in and for the State of California, residing therein, duly commissioned and sworn, personally appeared STEVEN GRAVES -PROVED TO ME )b0g90to be the person whose name subscribed to the within instrument and acknowledged that he executed the same. WITNESS my hand and offical seal. SANDY A. STACK ■ NOTARY PUBLIC -CALIFORNIA ■ ■ Butte County ■ A My Commission Expires Nov. 3,1989Ik 9 SANDY A STACK Name typed or printed AFTER COMPLETION, THIS DOCUMENT MUST BE RECORDED IN THE OFFICE OF THE COUNTY RECORDER. LD 1540 (5/88) 040-21-5-009-0 GRANT DEED TkA,,vS-- . W PA," FOR A VALUABLE CONSIDERATION, receipt of which is oereby acknowledged. ROSETTA F. CLARK, a married woman, dealinq with her separate property who acquired t tle as ROSETTA CHAPPELL, a widow hereby GRANT(S) to STEVEN R. GRAVES and VANESSA L. GRAVES, HUSBAND AND WIFE , as Joint Tenants the real property in the jkX*kX unincorporated `tate of California, described as County of Butte Lot 12, the South 20 feet of Lots 17 and 18, and the South 107 feet of Lot 11, in Block A of the Town of Durham, according to that certain Map entitled, f "OFFICIAL MAP OF BLOCK "A" OF THE TOWN OF DURHAM, BUTTE COUNTY, CALIFORNIA," which Map was'filed in the Office of the Recorder of the County of Butte, State of California, on October 23, 1924, In Book A of Maps, at Page 5.2. A EXCEPTING THEREFROM said Lot 11, the right to use as a private alley, in common with others, the Southerly 59 feet and 8 inches thereof. Gated --- November a, 1986 -------------- ----.. STATE OF CALIFORNIA Eutte rss COUN *,Y CFOr— November 4, 1986 [ afnre me• the orndersigned. a Notary Public in and for said Slat 1. per - Rosetta F. Clark sonally aDDeAred. — ------ I--------------------- -- ROSETTA F. CLARK 8s-39970 t ' Order No. 71%-:::2_J :R C: F:; Escrow No. 90355 LP ( OFEUIIECOU%TY..ALIFOft A AT THE REQUEST OF Loan No. MiD VALLEY TiT, LE CO. IA NOV -% PM 12: 35 WHEN RECORDED MAIL TO: ELEANOR M. CEUDI STEVEN R. GRAVES, ETUX CLERK -RECORDER FEC _ ' 2362 Durham Street 816-39970 Durham, California 95938 r Pegr SPACE ABOVE THIS LINE FOR NECOROE R'S USE MAIL TAX STATEMENTS TO: pOCUAAENTARY TRANSFER TAX 5. .... 5.8...3.Q ....... _.................. ..X. Computed on the consideration or value of property comeyeA: OR a SAME AS ABOVE ...... Computed on the consideration or value leu liero or encumbrances remaining attide of sale. Sianeture of Declarant or Agent d.terminlnp te• - Firm Nemo MID VALLEY TITLE AN') ESCROW COMPANY 040-21-5-009-0 GRANT DEED TkA,,vS-- . W PA," FOR A VALUABLE CONSIDERATION, receipt of which is oereby acknowledged. ROSETTA F. CLARK, a married woman, dealinq with her separate property who acquired t tle as ROSETTA CHAPPELL, a widow hereby GRANT(S) to STEVEN R. GRAVES and VANESSA L. GRAVES, HUSBAND AND WIFE , as Joint Tenants the real property in the jkX*kX unincorporated `tate of California, described as County of Butte Lot 12, the South 20 feet of Lots 17 and 18, and the South 107 feet of Lot 11, in Block A of the Town of Durham, according to that certain Map entitled, f "OFFICIAL MAP OF BLOCK "A" OF THE TOWN OF DURHAM, BUTTE COUNTY, CALIFORNIA," which Map was'filed in the Office of the Recorder of the County of Butte, State of California, on October 23, 1924, In Book A of Maps, at Page 5.2. A EXCEPTING THEREFROM said Lot 11, the right to use as a private alley, in common with others, the Southerly 59 feet and 8 inches thereof. Gated --- November a, 1986 -------------- ----.. STATE OF CALIFORNIA Eutte rss COUN *,Y CFOr— November 4, 1986 [ afnre me• the orndersigned. a Notary Public in and for said Slat 1. per - Rosetta F. Clark sonally aDDeAred. — ------ I--------------------- -- ROSETTA F. CLARK AP NO. ��Z /� S 01 ' 89-030335 Rec Fee 7.00 Check 7.00 Recorded ; 1 Official Records ; County of Butte ; Candace J. Grubbs ; Recorder ; 110:07am 7 -Sep -88 ; 'BG 2 NOTICE OF CONSTRUCTION AFFECTING ADJOINING PROPERTY The undersigned, do hereby declare as follows: 1. I am, ( are), the owner(s) of that certain real property situated in the County of Butte, State of California, described in attached Exhibit A. 2. I, (1P), intend to apply to the County of Butte for a building permit and, pursuant to said permit, to construct improvements on the said property. I, ), do hereby place all subsequent purchasers and encumbrancers on notice that such improvements will be constructed over a parcel or lot line(s) as described in the above noted Exhibit A, and that subsequent purchasers and encumbrancers should be aware of the location of such improvements. 3. So long as such improvements remain, said parcels or lots cannot be sold separately. DATED: Signature of owner of record STATE OF CALIFORNIA ss. COUNTY OF BUTTE Signature of owner of record STEVEN GRAVES On SEP'T'EMBER 7 , 19_before me, the undersigned, A Notary Public in and for the State of California, residing therein, duly commissioned and sworn, personally appeared STEVEN GRAVES PROVED TO ME %Ugg000goM to be the person whose named subscribed to the within instrument and acknowledged that he executed the same. WITNESS my hand and offical seal. -� '« M mse-manamme®omoaeOmanamaBig. SANDY A. STACK � a NOTARY PUBLIC -CALIFORNIA a B Butte County Q My Commission Expires Nov. 3,1989 ®ato®®®osa��ata®�■®�r�aoao■®� NOW SANDY A. STACK Name typed or printed AFTER COMPLETION, THIS DOCUMENT MUST BE RECORDED IN THE OFFICE OF THE COUNTY RECORDER. LD 1540 (5/88) 11 i Order No. Escrow No. 90355 LP Loan No. WHEN RECORDED MAIL TO: STEVEN R. GRAVES, ETUX 2362 Durham Street Durham, California 95938 -?9970 CF EUTTE COUNTtCAUFORN14 AT THE REQUEST OF MID VALLEY TITLE CO, ISEG WOV -7 PM C1. 35 ELEANOR H. CECY,ER CLERIC -RECORDER FEE_ 86-399'70 Lj MAIL TAX STATEMENTS TO: ~ DOCUMENTARY TRANSFER TAX S._.18...3.Q........ .._. ..X. Computed on the consideration or value of property convayaA: OR SAME AS ABOVE ...... Computed on ltl[e consideration or value less liens or encumbrances remai"" et 7e of sale. _ Slpruture of paclaren[ or Agent oe[erm l nlnp u. - Flrm N.me MID VALT,EY TITLE AN'� ESCROW i OMPA°' 040-21-5-009-0 GRANT DEED tRA,\4S: .. zu P,qw FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, ROSETTA F. CLARK, a married woman, dealing with her separate property who acquired t tle as ROSETTA CHAPPELL, a widow hereby GRANT(S) to STEVEN R. GRAVES and VANESSA L. GRAVES, HUSBAND AND WIFE as Joint Tenants the real property in the:U)t)fkX unincorporated County of Butte `:tate of California, described as Lot 12, the South 20 feet of Lots 17 and 18, and the South 107 feet of Lot 11, in Block A of the Town of Durham, according to that certain Map entitled, "OFFICIAL AAP OF BLOCK "A" OF THE TOWN OF DURHAM, BUTTE COUNTY, CALIFORNIA," which Map was filed in the Office of the Recorder of the County of Butte, State of Californa, on October 23, 1924, In Book A of Maps, at Page 5.2. EXCEPTING THEREFROM said Lot 11, the right to use as a private alley, in common with others, the Southerly 59 feet and 8 inches thereof. Dated November d, _1986 STATE OF CALIFORNIA ButteIss COUNTY OF._. 1 On— November 4, 1986 bfnre rne, the undersigned a Notary public In and for said Stat �. per- sonally appeared—. Rosetta F. Clark ROSETTA F. CLARK iz 41. OFFICIA1.1 SE END OF DOCUMENT COUNTY OF BUTTE--bERARTMENT OF PUBLIC WQRKS IJCounty Center Drive - Oroville, California 95965 - Telephone 916/534-4541 f' APPLIC)VION AND PERMIT PERMIT NO ASSES$OR PARCEL NUMBER ZONING BUILDING PERMIT OWNER TELEPHONE John C 1&rk ( 91-0872 SQ. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 2362 Durham bt., tXr..:em "'A. 9 3 CONTRACTOR'S NAME hie:-) tfirc TELEPHONE t: )1-1911 CONTRACTOR'S MAILING ADDRESS 19 'Esplanade, (, A -�(. C.: Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation is Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING ADDRESS �v9p I�, ? �� y rl PLUMBING PERMIT Filing Fee 10.00 ` Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF El Duplex[-]Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler s p y 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Uti Iities ❑ Installation ❑ Other ®'' Describe work: new service Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 1100 AMPOR S ORLESS 5.00 fever ' Main service//EA. ADD'L 100 AMP 2.50 NEW CONST. OR ADDNS. l ACCLBL GS.LING CCUP.N\ I 20 sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): -. p I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. 7Q0 9L2 Classification "..7 11 ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professiens Code for this reason NEW CONSTR I -OUTLET NON.RESID BRANCH CIRC ITS 2.50 ea NEW CONSTR (POWER APPARATUSFJ� 01 NON-RESID. (SINGLE OUTLET CIR. / Ex. Occup OUTLETS OR FIXTURES a �@1 IXED APPLNS. OR EX. Occup.(OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 lJ�� .-�rV -,., r -: . -5- j Permit Fee '71" ...� $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation —+ permit Fee S Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said C,unty'•jn,consequence of the granting of this permit. X )' r j Si4j S• 1 1 Q/ /�j 1 r Date Signature of Applicant Owner ❑ Contractor EJ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures overr storriies in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE 6"J oo OCCUP. GROUP I TYPE OF CONST, JPARCFLJ PD 1 HD I 1S5o� This permit is hereby issued under the applicable provi- sions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS r By PERMIT EXPIRES Date it�.t" /A—e!+ Receipt No. C� WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT A � ���✓�/ rte �� � � ��� ���� ��- � ,o��� ���� r J I ,COUNTY OF'BUTTE -'DEPARTMENT OF PUBLIC WORK P RMI 0. 7 County Center Drive - Oroville, California 95965 - Telephone 916/534 5 APPLICATION 0D PERMIT , ASSE4SOR,7SCEL NUMBER i ZONING BUILDING PERMIT OWNER j John Clark TELEPHONE 891-o872 SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 2362 Durham St., Durham CA. 95938 CONTRACTOR'S NAME Chico Electric TELEPHONE 1891-1933 CONTRACTOR'S MAILING ADDRESS 1933 Esplanade, Chico, CA. 95926 Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING ADDRESS She PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF F1 Duplex❑ Mobilehome❑ Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Instal lation ❑ Other Describe work: new service Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100V OR L 00 AMP ORSLESS 5.00 • 0 Main service EA_ ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.y\ OR AODNS. ACC. SLOGS. 2� sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, D'v. 3 of the Business and Professions Code and my license is in full force and effect. License No. .09O!98P Classification CID ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ 1 am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR. I -OUTLET 2.50 ea NO N.R ESID BRANCH CIRC ITS NEW CONSTR. POWER APPARATUS D\ NON.RESID. SINGLE OUTLET CIR. 1 Ex. Occup OUTLETS OR FIXTURES BAL01 00 XED APPLNS. OR EX. Occup. (0%TLETS (RESID,) EA./ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 7. i_/KzS Permit Fe22 _� $ Contractor MECHANICAL PERMIT FiIirig Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ® I have placed on file with the County of Butte- Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to ente on the above-mentioned property for inspection purposes. Iso agree to s e, indemnify and keep harmless the County of Butte against Lail iabiIities, jud ents, costs, and expenses which may in any way accrue agai t id unty 'n ons rice of the granting of this permit. X Date 10/9/81 Signature of Applicant — Owner ❑ Contractor F1 Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 storiesin height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ 3 �Q OCCUP. GROUP177TYPE of CONST. PD HD SSD �/ This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DtR TOR OF P ELIC By. KDate PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS �'a Receipt No. J� �S(4 7` WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT V ,a r COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS ai. 196 Memorial Way, Chico — Phone:691-27.51 7 County Center Drive, Oroville — Phone: 538-7541 7r 747 Elliott Road, Paradise— Phone: 872-6307 CORRECTION NOTICE ER ERMI T NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. 'r � � A t: .t fes= il? Y•� Date 412 Inspector a t r " s COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone: 916.'538.7541 • • APPLICATION AND VERMIT PERMIT NO. ASSESSOR PARCEL NUMBER 4p-215 ZONING BUILDING PERMIT OWNER Steven & Vanessa Graves TELEPHONE 89"798 SO.FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 2362 Durham St., Durham 95938 CONTRACTOR'S NAME L m Electric TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN C Total Valuation $ LENDER'S MAILING ADDRESS f Filing Fee $ 15,00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS' Permit fee $ PLUMBING PERMIT Filing Fee 15.00 2362 Durham St.. Durham 95938 I Each Trap 5.00 ? Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP t Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTUREI SF [X Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home I S I G JW I @ 15.00 TYPE OF WORK New ❑ Addition U Remodel ❑ Utilities ® Installation ❑ Other ❑ Describe work: D.U.M. _ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 t Main service 600V OR LESS 200A OR LESS 18.50 CONTRACTORS LICENSE LAW 1 I declare under penalty of perjury (check one): i I ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license Is In full force and effect. License No. Classification 1 ❑ I, as the owner, or my employees with wages as their soleRcompen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract - ors. (Sec. 7044) ❑ 1 am exempt under Sec. , Business and Professions Code for this reason Main service 200A TO IOOOA) 37.50 NEW CONST. DWELLING OCCUR.&) 3.60sq.ft. OR ADDNS. ACC. BLDGS. // NEW CONSTR. ULTI-OUTLET @ 5.00 NON-RESID. BRANCH CIRC ITS (POWER APPARATUS e1 SINGLE OUTLET CIR. I 20 76d EX. OCCUp OUTLETS OR FIXTURES FIXED APLNS. EX. Occup. OUTLETS P(RESID,)REA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring 1 15.00 15.00 Permit Fee $481.30 — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): u The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 15.00 Heating Cooling g Hood 6.50 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes.DCC I also agree to save, indemnify and keep harmless the County of Butte against, all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X ' t ' Date �� - %� Signature of Applicant — Owner 5 Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ CONST TYPE TOTAL FEE $48.50 I I HAz I DFEES I IMP FLOOD I CDF PARCELPD HD ISSUE This permit is hereby issued under the applicable provi- sions of the Butte County Code and/or resolutions to do work indicate4 aboveff ' which fees have been paid. r IRE TOF3'OF PUBLIC WORKS BY ���t/1 %=— Date/ ?5- rl PEWIT EXPIRES Date y Receipt NO. 200963 WHITE-D.P.W., YELLOW -ASSESSOR' PINK -INSPECTOR, GOLDENROD -APPLICANT I '.1 .,a 040-21-5-009' 91-3766`: GRAVES, STEVEN, VANESSA CONTR: LYM ELECTRIC 2362 DURHAM ST, DURHAM UNDRGRND ELEC/SF CA Braced. wall lines A 3/8" C.D.X. plywood or 5/8"T-111 with grooves. Nail with 8 ds 6 o.c. at edges 8" o.c. field. Cover 3 16" o.c. stud bays or 2-24" o.c. stud bays. B 7/8 portland cement plaster on studs 16" o.c. nail wire lath with 1/2" long ,7/16" head nails ,r. or 16 ga. staples with 7/8" leg. 4 ft. panel length covering 3 stud bays at 16" o.c. or 2 stud bays at 24" o.c. Gypsum board, 1/2" min. thickness. nail 7" o.c. V all stud plates and edges (must block all edges) nail with 5d coolers at 7" o.c.. 6d coolers on 5/8" gyp.bd. screws may be used. Panel length 4ft. if gyp bd. applied both sides. 8 ft: in length if. applied one side. ( 3 stud bays at 16" o.c. 2 stud bays at 24" o.c.) DDHardboard sheathing (plywood or o.s.b.)4 ft. X 8 ft. or 4 ft. X 9 ft. 3/8" min. thickness on 16" oc or 24" o.c. stud bays. Nail with a ds 6" o.c. edges 8" oxfield on 2X or greater framing.members. panel length 4 ft. min: , EAlternat braced panel: 2'-8" min. length. 3/8" C.D.X. -plywood ood nailed with 8ds at 6" o.c. edges 8" o.c. field. ( Block all edges.) 1/2" min. anchor bolts at panel quarter points and Simpson PA1442'at panel ends(HPAI-ID22 or PH022 at foundation end cond's/ 2500 P.s.i. concrete Braced wall plates shall be nailed to the floor framing and top plates shall be nailed to the framing above per table 23 -II -B-1. Sills shall be bolted to the foundation or slab with 1/2" min. anchor bolts at 6 ft. O.C. min. Ty : 1Nit SIGN GARAGE HEADER DESIGN GONZALES RESIDENCE CARPORT CONVERSION AP# 040-215-009 Dead Load (pso 10 F'b Live Load (psD 20 E Total Load (pso 30 1.986264 Span (ft) 13 19.25 Tributary (ft) 8 83.44813635 w 240 M max 5070 D.FIR #2 F'b 900 F'v 180 E 1600000 D. FIR #1 1000 F'b F'v 180 E 1700000 4x6 Deflect. 1 48.53 #2 1.986264 78.53942244 A 19.25 #1 -1.869425 83.44813635 S 17.65 4x8 1 111.1 #2 0.867627 179.8007384 A 25.38 #1 0.81659 191.0382845 S 30.66 4x10 1 230.8 #2 0.417649 373.5194457 A 32.38 #1' 0.393081 396.8644111 S 49.91 4x12 1 415.3 #2 0.232105 672.1084307 A 39.38 #1 0.218452 714.1152076 S 73.83 3x8 1 79.39 #2 1.214175 128.4822738 A 18.13 #1 1.142753 136.5124159 S 21.9 f Qs1 RIX No '6 P. FN11- OF CAL���� A req (fv) S reqs - 1C 67.6 13 60.84 'Z�. �j�' �..� x i3 �� Ci•"yak V/ GARAGE HEADER DESIGN D.FIR #2 F'b 900 F'v 180 Dead Load (pso 20 E 1600000 Live Load (pso 10 Total Load (pso 30 _ Span (ft) 13 D. FIR #1 Tributary (ft) I8 F'b 1000 F'v 180 E 1700000 w 240 A req (fv) S req M max 5070 Di- * 2 13 67.6 ✓ 1 13 60.84 4x6 Deflect. 1 '48.53 #2 1.986264 78.53942244 A 19.25 #1 1.869425 83.44813635 S -17.65 4x8 1 111.1 #2.0.867627 179.8007384 A 25.38 #1 0.81659 191.0382845 S 30.66 4x10 1 230.8 #2 0.417649 373.5194457 A 32.38 #1 0.393081 396.8644111 S 49.91 4x12 1 415.3 #2 0.232105 672.1084307 A 39.38 #1 0.218452 714.1152076 S 73.83 3x8 1 79.39 #2 1.214175 128.4822738 A 18.13 #1 1.142753 136.5124159 S 21.9 0 GONZALES RESIDENCE CARPORT CONVERSION AP# 040-215-009 �X IZ Fid Z CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 1 Project Title.......... The Gonzales Addition Date..05/07/07 14:27:12 ******* Project Address......... 2362 Durham Street Durham, Ca. *v7.30* Documentation Author... Marty Runnells ******* Building Permit Energy Calculation Services 574 Manzanita Avenue, Ste 9- Plan Check Date Chico, CA 95926 530-894-8466 Field Check/ Date Climate Zone........... 11 Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition MICROPAS7 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kTDV/sf-yr) Design Design Margin Space Heating.......... 75.61 67.06 8.55 Space Cooling.......... 111.27 100.46 10.81 Water Heating.......... 13.79 13.79 0.00 Total 200.67 181..31 19.36 *** Building complies with Computer Performance *** GENERAL INFORMATION HERS Verification........ . Conditioned Floor Area..... Building Type .............. Construction Type ......... Vintage Assumptions ....... Fuel Type ................. Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -factor... Average Glazing SHGC....... Average Ceiling Height..... Not Required 1520 sf Single Family Detached Existing+Addition+Alteration Before 1978 NaturalGas Front Facing 170 deg (S) 1 1 FullYear Slab On Grade 2 12152 cf 1519 sf 16.1 % of floor area 0.94 Btu/hr-sf-F 0.65 8 ft BUTTE COUNTY BUILDING APPROVRD CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 2 Drniart T;r1P.......... The Gonzales Addition Date. .05/07/07 14:27:12 ��.J MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition t BUILDING ZONE INFORMATION Floor # of # of Cond- Thermo - Area Volume Dwell Peop- it- stat Zone Type (sf) (cf) Units le ioned Type HOUSE - Existing Vent Vent Verified Height Area Leakage or (ft) (sf) Housewrap Residence 994 7952 0.66 2.0 Yes Setback ADD - New (Added) Residence 526 4200 0.34 0.0 Yes NoSetback OPAQUE SURFACES 2.0 Standard No 2.0 Standard No Surface Length F2 Insul (ft) Factor R-val HOUSE - Existing 14 SlabEdge 162 HOUSE - Deleted 15 SlabEdge 28 ADD - New (Added) 16 SlabEdge 68 Appendix Solar IV Location/ Gains Reference Comments 0.730' R-0 No IV.26 U- SLAB Sheath- 0.730 Solar Appendix IV.26 Al SLAB Frame Area fact- Cavity ing Act Gains IV Location/ Surface Type (sf) or R-val R-val Azm Tilt Reference Comments HOUSE - 1 Wall Existing Wood 150 0.356 0 0 170 90 Yes IV.9 Al FRONT 2 Door Other 10 0.500 0 0 170 90 Yes IV.5 A4 FRONT 3 Roof Wood 22 0.300 0 0 125 90 Yes IV.1 Al FRONT 4 Roof Wood 22 0.300 0 0 215 90 Yes IV.1 Al FRONT 6 Wall Wood 236 0.356 0 0 260 90 Yes IV.9 Al LEFT 7 Wall Wood 222 0.356 0 0 350 90 Yes IV.9 Al BACK 17 Roof Wood 994 0.300 0 0 n/a 0 Yes IV.1 Al TO ATTIC HOUSE - 10 Wall Deleted Wood 159 0.356 0 0 80 90 Yes IV.9 Al RIGHT 11 Door Other 9 0.500 0 0 80 90 Yes IV.5 A4 RIGHT ADD - New (Added) 5 Wall Wood 111 0.102 13 0 170 90 Yes IV.9 A3 FRONT 8 Wall Wood 74 0.102 13 0 350 90 Yes IV.9 A3 BACK 9 Door Other 9 0.500 0 0 350 90 Yes IV.5 A4 BACK 12 Wall Wood- 240 0.102 13 0 170 90 No IV.9 A3 TO GARAGE 13 Door Other 18 0.500 0 0 170 90 No IV.5 A4 TO GARAGE 18 Roof Wood 525 0.032 30 0 n/a 0 Yes IV.1 A7 TO ATTIC PERIMETER LOSSES Surface Length F2 Insul (ft) Factor R-val HOUSE - Existing 14 SlabEdge 162 HOUSE - Deleted 15 SlabEdge 28 ADD - New (Added) 16 SlabEdge 68 Appendix Solar IV Location/ Gains Reference Comments 0.730' R-0 No IV.26 Al SLAB EDGE 0.730 R-0 No IV.26 Al SLAB EDGE 0.730 R-0 No IV.26 Al SLAB EDGE CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 3 Project Title.......... The Gonzales Addition Date...05/07/07 14:27:12 MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition FENESTRATION SURFACES Exterior Area U- Act Shade Orientation (sf) factor SHGC Azm Tilt Type Location/Comments HOUSE - Existing 1 Wind Front (S) 12.0 1.280 0.800 170 90 Standard FG1 2 Door Front (S) 10.0 0.990 0.740 170 90 Standard FG2 3 Wind Right (SE) 12.5 1.280 0.800 125 90 Standard FG3 4 Wind Front (S) 30.0 1.280 0.800 170 90 Standard FG4 5 Wind Front (SW) 12.5 1.280 0.800 215 90 Standard FG5 8 Wind Left (W) 18.0 1.280 0.800 260 90 Standard LG1 9 Wind Left (W) 18.0 1.280 0.800 260 90 Standard LG2 10 Wind Back (N) 16.0 1.280 0.800 350 90 Standard BG1 11 Wind Back (N) 6.0 1.280 0.800 350 90 Standard BG2 12 Wind Back (N) 16.0 1.280 0.800 350 90 Standard BG3 HOUSE - Deleted 16 Wind Right (E) 24.0 1.280 0.800 80 90 Standard RG1 17 Door Right (E) 8.5 0.990 0.740 80 90 Standard RG2 18 Wind Right (E) 24.0 1.280 0.800 80 90 Standard RG3 ADD - New (Added) 6 Wind Front (S) 9.0 0.400 0.400 170 90 Standard FG1 7 Wind Front (S) 24.0 0.400 0.400.170 90 Standard FG2 13 Door Back (N) 9.0 0.530 0.650 350 90 Standard BG1 14 Wind Back (N) 40.0 0.400 0.400 350 90 Standard BG2 15 Wind Back (N) 12.0 0.400 0.400 350 90 Standard BG3 SLAB SURFACES Area Slab Type (sf) HOUSE - Existing Standard Slab 994 ADD - New (Added) Standard Slab 525 HVAC SYSTEMS Verified Verified Verified Verified Verified Maximum System Minimum Refrig Charge Adequate Fan Watt Cooling Type Efficiency EER or TXV Airflow Draw Capacity HOUSE - Existing Furnace 0.780 AFUE n/a n/a n/a n/a n/a NoCooling 13.00 SEER No Yes No No No ADD - New (Added) RoomHP 6.60 HSPF n/a n/a n/a n/a n/a RoomHP 9.70 EER No No No No No CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 4 ID r T;r1P---------- The Gonzales Addition Date..05/07/07 14:27:12 --, - -- - MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition HOUSE - Existing Furnace Attic NoCooling Attic ADD - New (Added) RoomHP None RoomHP None R-2.1 Pre2001 No No R-2.1 Pre2001 No No R-n/a n/a n/a n/a R-n/a n/a n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** .The existing building incorporates higher opaque U -factors or F -factors than the defaults for the specified vintage. REMARKS All unknown energy values -for the existing residence are taken from Table R3.11, 2005 Residential Manual, Default Assumptions For Existing Buildings - Vintage Table. Additions and alterations typically have special rules for HVAC SIZING Verified Total Sensible Design Maximum Heating Cooling Cooling Cooling System Load Load Capacity Capacity Type (Btu/hr) (Btu/hr) (Btu/hr) (Btu/hr) HOUSE - Existing Furnace 65430 n/a n/a n/a NoCooling n/a 44109 52895 n/a . ADD - New (Added) RoomHP '10581 n/a n/a n/a RoomHP n/a 5187 6220 n/a Total 76011 49296 59115 n/a Sizing Location............ CHICO EXP STA Winter Outside Design...... 22 F Winter Inside Design....... 70 F Summer Outside Design...... 100 F .Summer Inside Design....... 75 F Summer Range ............... 37 F DUCT SYSTEMS Verified Verified Verified System Duct Duct Duct Surface Buried Type Location R -value Leakage Area Ducts HOUSE - Existing Furnace Attic NoCooling Attic ADD - New (Added) RoomHP None RoomHP None R-2.1 Pre2001 No No R-2.1 Pre2001 No No R-n/a n/a n/a n/a R-n/a n/a n/a n/a SPECIAL FEATURES AND MODELING ASSUMPTIONS *** Items in this section should be documented on the plans, *** *** installed to manufacturer and CEC specifications, and *** *** verified during plan check and field inspection. *** .The existing building incorporates higher opaque U -factors or F -factors than the defaults for the specified vintage. REMARKS All unknown energy values -for the existing residence are taken from Table R3.11, 2005 Residential Manual, Default Assumptions For Existing Buildings - Vintage Table. Additions and alterations typically have special rules for CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 5 Prn�ect Title.......... The Gonzales Addition Date..05/07/07 14:27:12 MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition REMARKS modeling to avoid an undue energy penalty. These modeling assumptions may result in a HERS verification note on the Certificate of Compliance. Such measure(s) are for modeling assumptions only. The general guideline is that when additions and alterations use existing equipment for space conditioning, the existing building zone and the addition zone use current Package D assumptions for the HVAC system to avoid an energy penalty, Package D in Zones 2 and 8 - 15 is 13 SEER with Verified Refrigerant Charge or TXV. Package D in Zones 1, 3 - 7 and 16 is 13 SEER. Note that existing duct systems being extended less than 40 linear feet into newly conditioned space do not require duct leakage testing. Conditioned square footage is determined by the conditioned footprint of each floor or level. Ceiling height is not used to determine floor area. Additionally, stair areas are counted at each floor or level. The reference FRONT orientation used in these calculations may or may not contain the entry door to the dwelling. This in no way affects the accuracy of these calculations. Any new wall between conditioned space and crawlspace or attic shall be insulated to a value of R-19 or greater. Energy Calculation Services has C -HERS raters on staff. If these documents require HERS inspections or testing we are certified to provide these services. Please call 1 (530) 894-8466 for additional information. i CERTIFICATE OF COMPLIANCE: RESIDENTIAL COMPUTER METHOD CF -1R Page 6 Prosect Title.......... The Gonzales Addition Date..05/07/07 14:27:12 . MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition COMPLIANCE STATEMENT This certificate of compliance lists the building.features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. DESIGNER or OW DOCUMENTATION AUTHOR Name.... LK Name.... Marty Runnells Company. Company. Energy Calculation Services Address. Address. 574 Manzanita Avenue, Ste 9 Chico, CA 95926 Phone... Phone... 530-894-8466 License. l6 p Signed.. 5Si ne G ate ate ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. ate MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 1 Pro'ect Title ........ The Gonzales Addition Date..05/07/07 14:27:12 project Address........ 2362 Durham Street *v7.30* Durham, Ca. Documentation Author... Marty Runnells ******* Energy Calculation Services 574 Manzanita Avenue, Ste 9 Chico, CA 95926 530-894-8466 Climate Zone........... 11 Cm,=thnr3 - - _ - - - MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- Fing Permit *150(a): Minimum R-19 insulation in wood framed ceiling or Date Field Check/ Date Climate Zone........... 11 Cm,=thnr3 - - _ - - - MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition Note: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. More stringent compliance requirements from the Certificate of Compliance supersede the items marked with an asterisk (*). When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES De- En- sign- force- n/a er ment *150(a): Minimum R-19 insulation in wood framed ceiling or equivalent U -factor in metal frame ceiling 150(b): Loose fill insulation manufacturer's labeled R -Value *150(c): Minimum R-13 wall insulation in wood framed walls or equivalent U -factor in metal frame walls (does not apply to exterior mass walls) *150(d): Minimum R-13 raised floor insulation in framed floors or equivalent U -factor 150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door covering the entire opening of the firebox b. Outside air intake with damper and control, flue damper and control 2. No continuous burning gas pilot lights allowed 150(f): Air retarding wrap installed to comply with Sec. 151 meets requirements specified in ACM Residential Manual —7 150(8): Vapor barriers mandatory in Climate Zones 14,16 only 150(1): Slab edge insulation - water absorption rate for the insulation material without facings no greater than 0.3%, water vapor permeance rate no greater than 2.0 perm/inch 118: Insulation specified or installed meets insulation quality standards. Indicate type and include CF -6R form Infiltration% —� 116-17: Fenestration Products, Exterior Doors and Exfiltration Controls 1. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage 2. Fenestration products (except field -fabricated) have label with certified U -factor, certified Solar Heat Gain Coefficient (SHGC), and infiltration certification 3. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed �L SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES De- En- MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 2 Prosect Title.......... The Gonzales Addition Date..05/07/07 14:27:12 MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition sign- force n/a er ment 110-113: HVAC equipment, water heaters, showerheads and faucets certified by the Energy Commission 150(h): Heating and/or cooling loads calculated in accordance with ASHRAE, SMACNA or ACCA 150(i): Setback thermostat on all applicable heating and/or cooling systems 150(j): Water system pipe and tank insulation and cooling systems line insulation 1. Storage gas water heaters rated with an Energy Factor less than 0.58 must be externally wrapped with insulation having an installed thermal resistance of R12 or greater 2. Back-up tanks for solar system, unfired storage tanks, or other indirect hot water tanks have R-12 external insulation or R-16 internal and indicated on the exterior of the tank showing the R -value 3. The following piping is insulated according to Table 150-A B or Equation 150-A Insulation Thickness: 1. First 5 feet of hot and cold water pipes closest to water heater tank, non -recirculating systems, and entire length of recirculating sections of hot water pipes shall be insulated to Table 1502 2. Cooling system piping (suction, chilled water, or brine lines), piping insulated between heating source and indirect hot water tank shall be insulated to Table 150-B and Equation 150-A 4. Steam hydronic heating systems or hot water systems >15 psi, meet requirements of Table 123-A 5. Insulation must be protected from damage, including that / to sunlight, moisture, equipment maintenance and wind / 6. Insulation for chilled water piping and refrigerant suction piping includes a vapor retardant or is enclosed entirely / in conditioned space 7. Solar water -heating systems/collectors are certified by the Solar Rating and Certification Corporation - *150(m): Ducts and Fans 1. All ducts and plenums installed, sealed and insulated to meet the requirements of the CMC Sections 601, 602, 603, 604, 605 and Standard 6-5; supply -air and return -air ducts and plenums are insulated to a minimum installed level of R-4.2 or enclosed entirely in conditioned space. Openings shall be sealed with mastic, tape, or other duct -closure system that meets the applicable requirements of UL 181, UL 181A, or UL 181B or aerosol sealant that meets the requirements of UL 723. If mastic or tape is used to seal openings greater than 1/4 inch, the combination of mastic and either mesh or tape shall be used — 2. Building cavities, support platforms for air handlers, an plenums defined or constructed with materials other than sealed sheet metal, duct board or flexible duct shall not be used for conveying conditioned air. Building cavities and support platforms may contain ducts. Ducts installed in cavities and support platforms shall not be compressed to cause / reductions in the cross-sectional area of the ducts 3. Joints and seams of duct systems and their components MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 3 Prn�ect Title.......... The Gonzales Addition Date..05/07/07 14:27:12 MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition shall not be sealed with cloth backed rubber adhesive duct tapes unless such tape is used in combination with mastic and draw bands 4. Exhaust fan systems have back draft or automatic dampers 5. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers 6. Protection of Insulation. Insulation shall be protected from damage due to sunlight, moisture, equipment mainten- ance and wind. Cellular foam insulation shall be protected as above or painted with a coating that is water retardant and provides shielding from solar radiation that can cause degradation of the material 7. Flexible ducts cannot have porous inner cores 114: Pool and Spa Heating Systems and Equipment 1. A thermal efficiency that complies with the Appliance Efficiency Regulations, on-off switch mounted outside of the heater, weatherproof operating instructions, no electric resistance heating and no pilot light 2. System is installed with: a. At least 36 inches of pipe between filter and heater for future solar heating b. Cover for outdoor pools or outdoor spas. 3. Pool system has directional inlets and a circulation / pump time switch 115: Gas-fired central furnaces, pool heaters, spa heaters or household cooking appliances have no continuously burning pilot light (Exception: Non -electrical cooking appliances with pilot < 150 Btu/hr) 118(i): Cool Roof material meets specified criteria RESIDENTIAL LIGHTING MEASURES De- En- sign- force n/a er ment 150(k)l: HIGH EFFICACY LUMINAIRES OTHER THAN OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, and do not contain a medium screw base socket (E24/E26) Ballast for lamps 13 watts or greater are electronic and have an output frequency no less than 20 kHz 150(k)l: HIGH EFFICACY LUMINAIRES - OUTDOOR HID: contain only high efficacy lamps as outlined in Table 150-C, / luminaire has factory installed HID.ballast 150(k)2: Permanently installed luminaires in kitchens shall be high efficacy luminaires. Up to 50 percent of the wattage, as determined in Sec. 130(c), of permanently installed luminaires in kitchens may be in luminaires.that are not high efficacy luminaires, provided that these luminaires are controlled by switches separate from those controlling the high efficacy luminaires 150(k)3: Permanently installed luminaires in bathrooms, garages, laundry rooms, utility rooms shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) that does not turn on automatically or have an always on option 150(k)4: Permanently installed luminaires located other than in kitchens, bathrooms, garages, laundry rooms, and utility MANDATORY MEASURES CHECKLIST: RESIDENTIAL MF -1R Page 4 .,,«- m4f-lc ThP Gonzales Addition Date..05/07/07 14:27:12 F MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition rooms shall be high efficacy luminaires (except closets less than 70 ft2), OR are controlled by a dimmer switch OR are controlled by an occupant sensor(s) that complies with Section 119(d) that does not turn on automatically or have an always on option 150(k)5: Luminaires that are recessed into insulated ceilings are approved for zero clearance insulation cover (IC) and j ,are certified.air tight to ASTM E283 and labeled as air tight (AT) to less than 2.0 CFM at 75 Pascals 150(k)6: Luminaires providing outdoor lighting and permanently mounted to a residential building or to other buildings on the same lot shall be high efficacy luminaires (not in- cluding lighting around swimming pools/water features or other Article 680 locations) OR are controlled by occupant sensors with integral photo control certified to comply with`Section 119(d) 150(k)7: Lighting for parking lots for 8 or more vehicles shal have lighting that complies with Sec. 130, 132, and 147. Lighting for parking garages for 8 or more vehicles shall have lighting that complies with Sec. 130, 131, and 146 150(k)8: Permanently installed lighting in the enclosed, non - dwelling spaces of low-rise residential buildings with four or more dwelling units shall be high efficacy luminaires OR are controlled by an occupant sensor(s) certified to comply with Section 119(d) RESIDENTIAL KITCHEN LIGHTING WORKSHEET WS -5R Page 1 Prn;Pr_t Title.......... The Gonzales Addition Date..05/07/07 14:27:12 MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition At least 50% of the total rated wattage of permanently installed luminaires in the kitchen must be in luminaires that are high efficacy luminaires as defined in Table 150-C. Luminaires that are not high efficacy must be switched separately. KITCHEN LIGHTING SCHEDULE High Efficacy Luminaire Type (Yes/No) Watts High Efficacy Quantity Watts x = or X = or X = or x = or x = or Total A= Complies if A >= B Yes Rules for Determining Residential Kitchen Luminaire Wattage B= No Other Watts Screw Base Sockets - Section 130(c) 1 (Not containing permanently installed ballasts) The maximum relamping rated wattage of the luminaire, as listed on a permanent factory -installed label (luminaire wattage is not based on type or wattage of lamp that is used). Permanently or Remotely Installed Ballasts - Section 130(c) 2 The operating input wattage of the rated lamp/ballast combination based on values published in manufacturerTs catalogs based on independent testing lab reports. Line Voltage Track Lighting (90 through 480 volts) - Sectign 130(c) 3 1. Volt-ampere (VA) rating of the branch circuit(s) feeding the tracks; or 2. For tracks equipped with an integral current limiter, theihigher of - The wattage (or VA) rating of an approved integral current limiter controlling the track system or - 15 watts per linear foot of the track; or 3. For tracks without an integral current limiter, the higher of - 45 watts per linear foot of the track or - The total wattage of all of the luminaires included in the system. Low Voltage Track Lighting (less than 90 volts) - Section 130(c) 4 Rated wattage of the transformer feeding the system, as shown on a. permanent factory -installed label Other Lighting - Section 130(c) 5 (Lighting systems that are not addressed in Sections 130 (c) :1-4) The maximum rated wattage, or operating input wattage of the system, listed on a permanent factory installed label, or published in manufacturer's catalogs, based on independent testing lab reports. HVAC SIZING HVAC Page 1 Project Title.......... The Gonzales Addition Date..05/07/07 14:27:12 Project Address........ 2362 Durham Street ******* Durham, Ca. *v7.30* Documentation Author... Marty Runnells ******* Energy Calculation Services 574 Manzanita Avenue, Ste 9 Chico, CA 95926 530-894-8466 Climate Zone........... 11 Compliance Method...... MICROPAS7 v7.30 for 2005 Standards by Enercomp, Inc. MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -HVAC SIZING User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition GENERAL INFORMATION Floor Area ................. Volume ..................... Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...... Winter Inside Design....... Summer Outside Desi.gn...... Summer Inside Design....... Summer Range ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction....... Description 1520 sf 12152 cf Front Facing CHICO EXP STA 39.7 degrees 22 F 70 F 100 F 75 F 37 F Yes Yes Yes 0.19 HEATING AND COOLING LOAD SUMMARY Heating (Btu/hr) Opaque Conduction and Solar...... 41026 Glazing Conduction and Solar..... 10999 Infiltration ..................... 6540 Internal Gain .................... n/a Ducts ............................ 17446 Sensible Load ..................... Latent Load ...................... Minimum Total Load 170 deg (S) Cooling (Btu/hr) 21284 11023 2085 2055 12848 76011 49296 n/a 9820 76011 59115 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outside air, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING HVAC Page 2 Prn;ect Title.......... The Gonzales Addition Date..05/07/07 14:27:12 _ J MICROPAS7 v7.30 File-07205ADD Wth-CTZ11S05 Program -HVAC SIZING User#-MP1333 User -Energy Calculation Servic Run -1520 SF Existing+Addition 0 HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'HOUSE' Floor Area.. .... 994 sf Volume...... ................... 7952 cf Heating Description (Btu/hr) Opaque Conduction and Solar...... 34208 Glazing Conduction and Solar..... 9138 Infiltration ..................... 4637 Internal Gain .................... n/a Ducts ............................ 17446 Sensible Load .................... 65430 Latent Load ...................... n/a Minimum'Zone Load 65430 ZONE 'ADD/N' Floor Area ....................... 526 sf Volume ............................ 4200 cf Heating Description (Btu/hr) Opaque Conduction and Solar...... Glazing Conduction and Solar..... Infiltration ..................... Internal Gain .................... Ducts ............................ Sensible Load .................... Latent Load ...................... r Cooling (Btu/hr) 19484 8787 147.8 1511 12848 44109 8786 M Cooling (Btu/hr) 6817 1800 1861 2236 1903 607 n/a 544 0 0 10581 5187 n/a 1033 Minimum Zone. Load 10581 6220 COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Orovllle, California 95965 - Telephone: 916.'538-7541 APPLICATION AND PERMIT P RMIT N0. _ ASSESSOR PARCEL NUMBER 40 -215 -moi ZONING' BUILDING PERMIT OWNER Steven & Vanessa Graves TELEPHONE 891-6798 SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 2362 Durham St., Durham 95938 CONTRACTOR'S NAME L m Electric TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation is LENDER'S MAILING ADDRESS Filing Fee $ 15,00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ,. ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 15.00 2362 Durham St., Durham 95938 Each Trap 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or vent 7.00 USE OF STRUCTURE SF [X Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home I S I G JW I @ 15.00 TYPE OF WORK New U Addition ❑ Remodel ❑ Utilities ® Installation❑ Other ❑ Describe work: D.U.U.D. Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200V OR LESS 00A OR LESS 118.50 18.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) I, as the owner, am exclusively contracting with licensed contract ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason Main service 200A TO 1000A1 37.50 DWELLING OCCUP.&) NEW CONST.OR ADONIS. / ( ACC. BLDGS. / 3.6C sq.ft. NEW CONSTR MULT'-OUTLET NON-RESID, BRANCH CIRC ITS @ 5 00 POWER APPARATUS &) (SINGLE OUTLET C'R. ) Ex. Occup(OUTLETS OR FIXTURES 20 @ 76d FIXED Ex. Occup. OUTLETS P(RESID ) EA.) 1 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. byirin g 1 15.00 15.00 Permit Fee $48.50 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIingFee 1 15.00 Heating Cooling Hood 6.50 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. so a e to save, indemnify and keep harmless the County of Butte against li ilities, judgments, osts, and expenses which may in any way accrue t said County in sequence of the granting of this permit. ef Date is -aa -si il Signature of Applicant — Owner % Contractor ElAgent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee S Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $48.50 HAz DFEES IMP FLOOD CDF PARCEL PD RDi This permit is hereby issued under the sions of the Butte County Code and/or work indica above which fees R F PUBLIC BY PE MIT EXPIRES Date /171;_�j applicable provi- resolutions to do have been paid. WORKS Z Receipt No. 100963 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT �cj. *[T• �+r•"'I�T_.. .. . + '" A�+M I,'A,�SM["—TS�f ',"-'{El�f��'""M7���""��C-.i /'.Ri..��+�[ '' "Y �".1.�'�A�L.%�r f �'7 i� �� t^;k`- " i��.i+��� a A COUNTY OF BUTTE - DEPARTMENT'OF,RUBLIC WORKS --BUILDING DIVISIO 7 COUNTY CENTfR DRIVE - OROVIL,LE, CALIFORNIA 95965 -TELEPHONE: 916/538-7541 766 • _�• v PERM11 APPLICATON�DATA SHEET «. Permit No. OWNER P. No. -Y0 ' Propose4Bu Tg,n,. U Building Inspecto Date At time of permit application, I was advised the following data must be submitted prio t permit processing and/or issuance: 'DATE 1. RECEIVED APPROVED All items have been submitted. + 2. Plot plans in duplicate/triplicate, signed by preparer of plans........ 3. Complete plans in duplicate/triplicate, signed by preparer. of•plans . . 4. Complete engineered plans and calcs, with wet signature on plans .. 5. Hazardous Material Form .......................................... = 6. Energy Design Compliance and supporting documentation ......... 7. Statement of Intent for Non -Heated and AC Buildings .............. 8. Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation instructions....................................................... 10. Fees of $ 11. Chico Urban Area fees paid .................... 12. Park fees paid .................................................... 13. School District fees paid .............. 14. Sanitation approval from Health Department 15. City of Chico plumbing permit ..................................... 16. Plot plan and business license approval from City of (see City for other requirements) ,. 17. Planning approval for (A) Use: (B) Parking: ...... 18. Improvements may be required. Contact Land Development Section DPW `. 19. Driveway permit (construction approval required prior to occupancy) 20. Pre -Inspection for required Pre-i"spec. request to Building Inspector (Date) 21. Contractor's license information (No., Name Style, Classifications ... 22. Certificate of Workmans Compensation Insurance .................. 23. Owner -Builder Verification (Given to owner ❑, Mail to owner ❑) ..... A 24. Recorded copy of Agricultural Acknowledgment Statement ......... 25. 4. Letter of signature authorization ............"1• ................... 26. 27. When you issue the permit, process as follows:. _Mail to owner. Mail to contractor. Telephoneand hold for'pickup at office. _Deliver w/inspector. Other - C' App. art i'�1o7 ?�G-O Date �el -aa �� , Copy of Haz-Mat form sent Health Dept. tXl Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By ,. The following data must be submitted prior to permit issuance: (Circle new -item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by—phone---mai [—counter by': Contractor, designer, owner, was advised of above required data by—phone —mal l—counter by - Plans checked b, Sets of plans on hold in Copy—DPW Date Plans approved by File cabinet AP folder ..date date Date COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Orovllle. California 95965 - Telephone: 916.`536-7541 APPfICATION AND PERMIT ASSESSOR PARCEL NUMBER � O Z ( S — ZONING BUILDING PERMIT OWNER �e r �eS ha s TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADD ESS CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation is LENDER'S MAILING ADDRESS Filing Fee $ 15.00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee ; ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS ._ I I Permit fee $ LL r V-, ave S PLUMBING PERMIT Filing Fee 15.00 Each Trap1 5.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 7.00 Each qas water heater or. vent 7.00 USE OF STRUCTURE SF6A—Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home I S I G JW I @ 15.00 TYPE OF WORK New ❑ Addition a Remodel ❑ Utilities ❑ Installation❑ Other _ Describe work: • C e n (rP 4-o U vt d e r C r o A. tY Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 15.00 SS Main service 200A OR LESS 18.501 is CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): ❑I am licensed under p provisions of Cha t. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification E] 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered . for sale. (Sec. 7044) �] I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) I am exempt under Sec. , Business and Professions Code for this reason Main service 20CATO1000AI 37.50 NEW CONST. DWELLING OCCUP.aI� OR ADONS. ACC. BLDGS. 3.6Csq.ft. NEW CONS R_ U TI -OUTLET NO N.R ESI D• BRANCH CIRC ITS @ 5.00 POWER APPARATUS e) SINGLE OUTLET CIR. Ex. OCCUp(OUTLETS OR FIXTURES 20 76d FIXED APLNS. Ex. OCCup. OUTLETS (RESID )REA.) I 3.00 Temporary service 1 15.00 Mobile Home Facilities 15.00 Misc. IYirin 9 1 15.00 Permit Fee $ . — WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check ane): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT FiIirig Fee 15.00 Heating Cooling Hood 6.50 Ventilation Permit Fee ; Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner❑ Contractor ❑ Agent ❑ An OSHA ion of structures over 39 stories in height. excavations over 5'0" deep and demolition or construct- Mobile Home Installation Fee S Energy Inspection Fee $ OCC CONST TYPE TOTAL FEES ��------ HAz OFEES I IMP I FLOOD I COF PARCEL PD HD ISSUE This permit is hereby issued under the sions of the Butte County Code and/or work indicated above for which fees DIRECTOR OF PUBLIC BY PERMIT EXPIRES Date applicable provi- resolutions to do have been paid. WORKS Date Receipt No. r^ In ARCHITECTURAL SYMBOLS TITLE 24 -REQUIREMENTS DETAIL N ENERGY REQUIREMENTS DETAIL BUBBLE REFER TO ATTACHED ENERGY A83 CERTIFICATE OF COMPLIANCE FOR �cJ SHEET DETAIL IS DRAWN SPECIFIC ENERGY REQUIREMENTS FOR THIS BUILDING ' oEui TIRE DETAIL TITLE ---- 1/4 wa�a DETAIL SECTION SYMBOL BUILDING SECTION SYMBOL A13 !� ENLARGED PLAN I OR ENLARGED DETAIL SYMBOL l 1 0 REVISION BUBBLE CD 0 4 I_ — -- -_ -- —_ _j --F. 7001_CB C. CMC, CPC, 2004 CEC, AND 2065_ JALIFORNIA 005- JALIFORNIA ENERGY STANDARDS >S AMENDED BY THE JURISDICTION APPLY TO THIS OROJECT N OTE: PROPERTY OWNER IS RESPONSIBLE -FOR DETERMINING LOCATIONS OF PROPERTY LINES AND EASEMENTS AND MAINTAINING REQUIRED SETBACKS FROM PROPERTY LINES AND EASEMENTS. A SURVEY MAY BE REQUIRED IF DETERMINED NECESSARY BY THE BUILDING OFFICIAL. `1 PROVIDE MINIMUM DISTANCE 1 FROM FOOTING OF STRUCTURE i OF 5 FT FROM ALL PORTIONS I OF PRIVATE SEWAGE DEPOSAL SYSTEM INCUDING SEPTIC TANK, LEACH AREA AND PITS�� 100' i �7EMiTING IEACH uNEs-------- -----t . ' _11 EIOSTING ( J 1500 GAL SEPTIC TANK I SAGE NEIN PLUMBING L -1- J 17 I CONNECTED TO EXIST. TANK --1 EXISTING HOUSE 17 APPROVED PLANS AN SITE PERMIT SHALL BE ON FOR ALL INPECTIONS I PROPOSED 16' CONVERSION EXISTING CARPORT EASITNG CONCRETE DRIVEWAY j, i I 17 ARM 2Dm REVISIONS I SKEET ADDFD — 3 SEE THE ATTACHED B:JT�TE SHEET INDEX w D_ Z N Z UJI z 0 W 0H V REQUIREMENTS T1 SITE PLAN ARCHITECTURAL DRAWINGS ' Z O V Al EXISTING FLOOR PLAN AND ELEVATION DRAWN BY - A2 NEW FLOOR PLAN MATT TEAGUE 1 v>' o) � 2367 DAYTON RD. A3 ' ELEVATIONS CHICQ,_4 95928 30) 83-1 A4 ELEVATIONS DA A5 SECTIONS A6 FOUNDATION PLAN A7 DETAILS QA8 NEW FLOOR PLAN (EXISTING_ STORAGE) t ' t I 0 r, BUILDING PERMIT# ASSESSOR'S PARCEL# ()i ✓ " 21 S' _- E COUP i SUL1.�IMG D1VISION A"' W01PROW ED 17 ARM 2Dm REVISIONS 1 12/17/07 SKEET ADDFD — SEE THE ATTACHED B:JT�TE RESIDENTIAL C^TTNTY Z N Z UJI z 0 W 0H V 100 — SEE THE ATTACHED B:JT�TE RESIDENTIAL C^TTNTY CONSTRUCTION FILE COPY .. 0 3 2n08uj REQUIREMENTS EVELOPMENT W �MO _ SERVICES O N � o _ T v>' o) � LUQ N O co) Og O IS REaV53 PLAN SEAT o "o a SITE FLAN THESE PLANS CONTAIN REVISIONS O NOTED BY DATE 0 I 1 . T1 .I , 0 00 N 16'- 0" aT EXISTING FLOOR PLAN ®" 1/e- - r -D- PROPOSED CONVERSION TO LIVING SPACE 0 Do N p an c ec `1 EXISTING AREAS LMNG AREA 994 SO. FT. COVERED CARPORT 952 SO. FT. DETACHED STORAGE 259 SO. FT. EXISTING FRONT. ELEVATION 1/e r -o - t rJ�7 z 0 CE cn 0 OC 0 LU O LL U O z IL V � W U W00 F- K) o Ln � O to rn '0 LU O UA O N � z cMv a O o a C7 Al 3 w w Of z o DRAWN BY: MATT TEAGUE 2367 DAYTON RD. CHICO.C 95928 I ( 0 93 1350 ATEV 1 APRIL 2007+ REVISIONS DATE Existing portion of structure not 1 h ked p an c ec `1 EXISTING AREAS LMNG AREA 994 SO. FT. COVERED CARPORT 952 SO. FT. DETACHED STORAGE 259 SO. FT. EXISTING FRONT. ELEVATION 1/e r -o - t rJ�7 z 0 CE cn 0 OC 0 LU O LL U O z IL V � W U W00 F- K) o Ln � O to rn '0 LU O UA O N � z cMv a O o a C7 Al PROVIDE ATTIC ACCESS MINIMUM SIZE 2211X30" IN CORRIDOR, HALLWAY OR OTHER READILY ACCESSIBLE LOCATION WITH 36" LEGEND UNOBSTRUCTED HEADROOM IN ATTIC CBC SECTION 1505.1 INDICATES METHOD OF BRACED WALL PANEL�_-BP - - - 18'-0" PER METHODS LISTED UNDER UBC 2320.11.3 INDICATES BRACED 4 FT. WALL PANEL PER ALT 1 UBC CHAP. 23 SECTION 2320.11.3 INDICATES ALTERNATE BRACED WALL PANEL - SEE DETAIL 1/A7 SEE ATTACHED BRACED 2 s� WALL SCHEDULE FOR COMPLIANCE OF CBC 2320.11.3 BP Provide SMOKE DETECTORS/ALARMS REQUIREMENTS As required by CBC 310.9 3'-6" r z. ` _ I — - I i a BATH (E) BEDROOM 5 I BP I CLOSET SET ( 2 LINEN 5-10 NEW AREAS LMNG AREA 1520 SQ. FT. PANTRY N GARAGE 685 SQ. FT. 2 ° FOR ALL PEX OR CPVC INSTALLATIONS, A COMPLETED "REQUEST TO USE PEX WATER PIPE" OR "CERTIFICATE OF COMPLIANCE FOR INSTALLATIONS OF CPVC PLUMBING MATERIALS FORM MUST BE SUBMITTED AND APPROVED BY THE BUILDING OFFICIAL/ Qi • Ci1 COMPLY. WITH CALIFORNAIA ELECTRICAL CODE- ART/o 410-8 REQUIREMENTS F LIGHTING FIXTURES IN CLOTHES CLOSETS BP 6�-2" ALT ®, NEW FLOOR PLAN _._......._....._..... I I BPALT . STEPS 6 6 dLDG. 2'-6" 14'-6" /14c r'* U Lv OBJ '41-L. #1 poo"n g LIf,CfAj G EDROOM Swr,, F_T5 r t''xlr_A`s 6'-10" I 7'-8" C 504 ENVIRONMENTAL AIR DUCTS SHALL BE INSTALLED AS DESCRIBED BY THIS CODE (E) STORAGE 2 1/rte n \ A5 2'-2" 4 BEAM 0 fil W/H 2 m 4X12 HEADER 26 26 pJ Z m C-1)3 �N WALK-IN M I �o t, I I M. BATH U-')>< o i I I O W J vC.7 I I Z 3 �C3 6 U -)o —4X12 HEADER d x o_ 2 1 HR RATED FIRE DOOR w/ CLOSURE !1` 0 DINING LAUNDRY io........ ............ ._ . _. _-._....-- �rD 'LXX , J r0�, EXISTING ........................_ 6X14 BEAM 6°4° 3 3°3° -10°8° -- — eGARAGE3DDOOR BP 4 jjLo� h /� ` ALT 12'-4" 5'-8" S� /dS 16'-0" 34'-0" �� %�7�0� �✓ 3 BP 01 0 I 00 N 17 P� z:5 On. W Li O O U 11- J cc LL O a a v Z W U z 00 O1 W H� o N �� � LU IS! cr V (I o CO) O Ing:4kZ N� BUTTE Cr_lllvgln�;9cl_ 0 3__ UlrNw'r W SEE SHEET A8 z ,h FOR NEW STORAGE AREA o FLOOR PLAN & L SECTION Q DRAWN BY: BP I MATT TEAGUE ALT 2367- DAYTON RE ( CHICO, CA 95921 (530) 893sc1350 W/H 2 m 4X12 HEADER 26 26 pJ Z m C-1)3 �N WALK-IN M I �o t, I I M. BATH U-')>< o i I I O W J vC.7 I I Z 3 �C3 6 U -)o —4X12 HEADER d x o_ 2 1 HR RATED FIRE DOOR w/ CLOSURE !1` 0 DINING LAUNDRY io........ ............ ._ . _. _-._....-- �rD 'LXX , J r0�, EXISTING ........................_ 6X14 BEAM 6°4° 3 3°3° -10°8° -- — eGARAGE3DDOOR BP 4 jjLo� h /� ` ALT 12'-4" 5'-8" S� /dS 16'-0" 34'-0" �� %�7�0� �✓ 3 BP 01 0 I 00 N 17 P� z:5 On. W Li O O U 11- J cc LL O a a v Z W U z 00 O1 W H� o N �� � LU IS! cr V (I o CO) O Ing:4kZ N� BUTTE Cr_lllvgln�;9cl_ 0 3__ UlrNw'r FRONT ELEVATION 1/4' - V-0' MATCH EXISTING LAP SIDING w LLI z 0 DRAWN BY. MATT TEAGUE 2367'DAYTON RD] CHICO, CA 95928 (5,30) S93)--1356 17 JPRL 2007 DATE REAR ELEVATION 1/4' - V -0 - ii A RIGHT ELEVATION 1/4. _ 1•-0. BUT -TE u Y y SUILDING DIVIS i'll 3 w w Of z 0 U DRAWN BY: MATT TEAGUE 2367 DAYTON RD. O co Fn Z >o z O Q U O J cc W a U °.P v z 00 LU F- V) O v N Obi Ln LU Q N O � W O (o z N� a 0 o Q 2X6 PULRIN EXIST. 6X14 BEAM DINING INTERIOR FOOTING #4 X 12" DOWELS INTO EXIST. SLAB ® 48" O.C. 077= SAWCUT AND EXCAVATE EXIST. SLAB AT NEW EXT. FOOTING 2X4 STRUT ® 6' O.C. _PURLIN TO BEARING WALL EXIST. 9" I -JOISTS ® 24" O.C. NEW BEARING WALLS — WALK-IN 2X6 PURLIN EXISTING ROOF: COMP. SHINGLES ON 7/16 OSB ON 2X6 RAFTERS'24" O.C. &aSECTION 2X6 PULRIN EXIST. 6X14 BEAM R-30 INSULATION BEDROOM NFW 4" SI AB R-19 INSULATION ® ALL NEW EXTERIOR WALLS �ow 1 3 A7 2X4 STRUT ® 6' O.C. _PURLIN TO BEARING WALL EXIST. 9" 1 -JOISTS ® 24" O.C. — A 4X12 BEAMS GARAGE ONLY GARAGE EXIST. SLAB 2X6 PURLIN 2 SECTION R-38 INSULATION EXIST. 6X14 BEAM SdUTTE 'LDIN II G IVIN." APPROVED (E) STORAGE I , 3 w w o' z 0 U DRAWN BY: MATT TEAGUE 2367 DAYTO RD. CHICO, GArg4928 )/>39 0 TE ,7 AM 2007 REVISIONS DALE z O_ cc o[ Z W Z O O V V W CL co at a V W U z 0c) °' W F -M O C V) a) O co) (3' U) W Q N CC mU O co) O NQ z N� o O oa A5 m M, CLOSET LINEN (E) FOOTING AND STEMWALL (E) STORAGE 3� BP ALT ALT - - ----- - - - - - - - -- - - - - - - - --------- --- (E) BEDROOM BEDROOM INTERIOR FOOTING SEE SECTION 1 SHT. A5 (E) FOOTING ----------- -- --------- -- A ------------AND STEMWALL w/ F FOUNDATION BOLTS ------------ I ---------- - - - - - - - - - - ---- - - - - - - - GARAGE CONCRETE SLAB OVER CLEAN PEA GRAVEL OVER EXISTING CONCRETE SLAB ----------------- - -- - - - - - - - - - - - - - - - - - - - - - - -- - - - --- - - CLOSET &P BP EXIST. FOOTING . .................................... 0 - - - - - - - - - - - - - - - - - - - - - --- - - o I BP BP ALT I ---------------I FOUNDATION PLAN EMSTMG CONCRETE SLAB ®R ALTi uz LL rolws Lu 0 > tr) I W N :2 a) Lo A ul < cr < L) co) o EXIST. FOOTING z 0Z) t. OEB�O DRAWN BY. _ 'ALT MATT TEAGUE 2367 DAYTON RD. CHICO, C 928 (5 3- 6'(:560� U4 REVISIONS A WE ti I. r4 A7 EMSTMG CONCRETE SLAB ®R ALTi uz LL rolws Lu 0 W He 00 V) tr) I BP N :2 a) Lo ul < cr < L) co) o EXIST. FOOTING Lu <a_j C'4 < Z*k Z 0 A6 �J i GARAGE DOOR HEADER . I . I . I OF SLAB OR STEM WALL 2'-8" MIN TOP PLATE 2x BLK'G. ® PLYWOOD JOINT EDGE NAIL ALL BOUNDARY MEMBERS 3/8" CDX OR OSB W/ 8d ® 8" O.C. EDDGES & 12" O.C. FIELD. STUDS, DBL. KING STUD WHERE HDR. OCCURS (2) 2x POST 2 — 1/2" x 10" A.B. W/ 7" EMB. SIMP. PHD2W/ SSTB16, TYP. —P.T. SILL OR SOLE PLATE CONT. FTG. W/ #4 MIN. TOP & BOT. ALTERNATE BRACED WALL ELEV. VIEW 1" = 1'-0" 4" CONC. SLAB W/ #4 ® 48" O.C. E.W. ANCHOR BOLTS PER DETAIL 2, THIS SHT. #4 ® 48" O.C. E.W. CLEAN PEA GRAVEL FILL O.G. #4 HORIZ SAWCUT EXIST. AT BOTTOM SLAB FOR NEW FOOTING 12" (D4LB FOOTING . VIEW 12" MAX 12" MAX WHERE PLATE IS DRILLED OT NOTCHED MORE THAN ONE-THIRD WIDTH OF THE PLATE, SILL BOLTS SHALL BE PLACED 9" MAX EA. SIDE OF CUT. PLATES LESS THAN 6" IN WIDTH SHALL NOT BE DRILLED OR NOTCHED EXCEPT FOR BOLTS. EACH PLATE SHALL HAVE TWO BOLTS MIN. PROVIDE WASHER AND NUT 4" CONC. SLAB W/ #4 ® 48" O.C. E.W. 2" X 2" X 3/16" PLATE WASHER, TYP. x a N z [ a D TYP. ANCHOR BOLT PLACEMENT PLAN VIEW 1" = I,-0" ANCHOR BOLTS PER DETAIL 2, THIS SHT. #4 ® 48" O.C. E.W. #4 HORIZ AT BOTTOM 4 SLAB FOOTING (GARAGE) S SEC. VIEW 1" = 1'-0" 3 w w Z 0 U DRANRJ BY: MATT TEAGUE 2367 DAaGF6N RD MITE CouNn'Y W RW LDWGDlVlSlr'�-t�^ z 00 V) a) 0 "I Lr) T-4 F4 co) o:i O Na qh N Z N� n 0 o a ( V A7 ER ■ 3 3 BP BP SHEET A2 UAKAUE SHEET A2 I MY ®, FLOOR PLAN SEE ATTACHED BRACED WALL SCHEDULE FOUR COMPLIANCE OF CBC .2320.11.3 REQUIREMENTS 3 w STORAGE CONSTRUCTION NOTES ' w z 1. CONTRACTOR TO VERIFY LOCATION. OF ALL EXISTING P FOUNDATION ANCHOR BOLTS AND SHALL INSTALL ADDITIONAL AT EACH PROPOSED BRACED WALL PANEL TO MEET REQUIREMENTS OF UBC 2320.11.3 AND 1806.6. FOR ADDITIONAL BOLTS, USE 1/2" DRAWN BY: HILTI KWIK BOLT 3 (KB -3) WITH MIN. 3-1/2" EMBEDMENT. MArr TEAGUE 2. EXISTING STORAGE CEILING TO REMAIN OPEN AND UNFINISHED. 2367.Ro t CHIC O9 9 i (5 , 93— 0 DA 17 APRIL 2007 LEGEND INDICATES METHOD OF BRACED WALL PANEL/S@"T PER METHODS LISTED UNDER UBC 2320.11.3 INDICATES BRACED 4 FT. WALL PANEL PER L � UBC CHAP. 23 SECTION 2320.11.3 (� Qj) INDICATES ALTERNATE BRACED WALL PANEL Cp .� SEE DETAIL 1/A7 EXISTING WALLS: LAP SIDING 0/ 2X4 STUDS ® 16" O.C. SEE FLOOR PLAN FOR BRACED WALL PANEL LOCATIONS EXISTING FOOTING EXIST. 4X6 STRONG -BACK EXIST. 2X4 TIES ® 24" O.C. EXIST. SLAB I I SHEET ADDED 1 W 0 WHM Do O In 0) oI co) mO Lo W Q N of O co) o J C-4= qh to Z N� d 0 o a (3 SECTION 1,. 1 ; la• -1-�' ilul ; " I ` 1 x, 4'1,4 r''` ! A8 t Z z 0 U)" Lu Ix Lu EXISTING ROOF: V Q N COMP. SHINGLES ON 7/16 OSB ON ¢ —1U. z 2X6 RAFTERS 24" O.C. Q N W 0 WHM Do O In 0) oI co) mO Lo W Q N of O co) o J C-4= qh to Z N� d 0 o a (3 SECTION 1,. 1 ; la• -1-�' ilul ; " I ` 1 x, 4'1,4 r''` ! A8 t FILE Copy OWNER VO/� N-� 1,'�'� "1��1 0" - Q BP#07 26303 F