Loading...
HomeMy WebLinkAbout040-370-011MICHAEL CLARK GORDON Everet£' 633-69B* 501-69B _485-69E;, 152 Estates Drive; Chico - Contr : Butte Roofing Company7 �`� y ` - - P Permit#3115-86B(reroof/patio/SF) 152 Estates Dr. Chico. x040370"01 1f ~PERMIT#97""2049, ' # - " . Y � t. (newi,s ngle ami--ly)---( add- covered porch) =W-ILLITS'ty &"Barbarai ' = "Cont ;Russ �Coll`ar,rG'/2-�3/ 97 "' ------•--� _ - 3Adc1'M .s •1' MILLIGAN, Fred 248-71B - - aster Bedrm/ Laundry /SFI + • .,,may-n .A••�r' i L .t 'ldP.:J. :.;,.. _ .k!y.YSplr'i t'F.,�`,�.N°;: •3' "' ,.,, _ _ 235-71P' 74 0-37-1 rpt{ ` 152"Estates Dr., Chico CONTR: Holiday Pools, 170 E.Lassen', Chico =' (new swimming pool) (o Nq {t ` �-t R t r i t s, hsr:' M RESIDENTIAL \� X040-370-011 ^PERMIT#97-2 40 9 ; WILLITS, Rusty & Barbara s PERMIT NC 152 .Estates.Dr.. , Chico. Cont: Russ Collar PERMIT EXI Add Master_Bedrm/Laundry/SF OWNER CONTR. ASSESSOR PARCEL LOCATION �j t� ki • k. it ' J f i f Temp. Power Pole i Celled PG&E Temp. Elec. Service Called PG&E k Temp. Gas Service Called PG&E J JOB FINALED (Date) Signature -- L V=OK > O = Not OK = No Applicable ble MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK accept #'s II 1. Zoning. Requirements -Setbacks -Easements 1. Zoning Requirements - Setbacks - Easements I 2. Footings; SoilsSao-DepthSpacing-Connectors-Steel 2. Soils; Special MH Support SkeE & Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer, Location-Test-Fall--CIO-Concrete 4. Wood Awn:; PostsBeams-Rftrs.-Connectors Sh!j:=Rfg.$racing 4. Water, Location -Test -Easement Needed (Sketch) 5. Alum. Awn.; Columns-ConnectionsSplice-Decal-Enclosures S. Electricity; Location-Clearances-Gmd-/ /Amp•Concrete 6. Carports; Windows -Doors 6. Gas; Location -Test -Wrap; / /'LYL / /Nat. or/ PL°fL/ "G 7. Electric 7. Well Clearance & Disconnect 8. Frmg.; Sills-Anctrors-Studs-Rftrs-Trusses 8. Utility Clearance 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing Date Card B-1 Date Card B-1 Date Card B-1 Date Cana B-1 _Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements- Setbacks Easements Cana B-1 Date Card B-1 2. Footings; SimeSpacng-Marriage Line POOLS (Plans) OK except #'s 3. Gas; MH Test-DemarKWalve-Connector I 1. Setbacks -Easements - 4. Electricity; MH Test•Crossovers-BreakersClearances 2. Soils; Compaction -Structure Stability 5. Drain; MH Test-FalWlex Connector 3. Pod Structure; SteelConnections-Thickness Dead Men -Lining 6. Water; MH Test -Regulator -Connector 4. Elec.; Receptacles and Lighting, Dlstance:GA 7. Water and Sewer Connected -C/0 to Grade -HD Approval . 5. Elec.; Pool Lighting; 15 Volts-GFI 8. Gas and Electricity Tagged 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 9. Tie Downs -Type -Installation Cert. 7. Elec.; Bonding; Metal w/5 -Circulating Equip. -Heater 10. Exits; Insp.-Sketch 8. Elec.; Grounding; Equip. w/S Circulating Equip. -Pool 1.ghtg. Boxes-Enclosures-Panelboards4ns. to Main in Conduit 11. Cert of Occupancy 9. Health Department Approval 12. Permanent Foundation Only: License Decal 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MISCELLANEOUS _Date DECKS, CONERS, CARAOR , AG S (Plans) OK except #'s II 1. Zoning. Requirements -Setbacks -Easements I 2. Footings; SoilsSao-DepthSpacing-Connectors-Steel & Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn:; PostsBeams-Rftrs.-Connectors Sh!j:=Rfg.$racing 5. Alum. Awn.; Columns-ConnectionsSplice-Decal-Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anctrors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext;, Steps•Doors-Landings 12. Braced Wall,Panels Date Card B-1 Date Card B-1 Date Cana B-1 Date Card B-1 Date POOLS (Plans) OK except #'s I 1. Setbacks -Easements - 2. Soils; Compaction -Structure Stability 3. Pod Structure; SteelConnections-Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Dlstance:GA 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/S Circulating Equip. -Pool 1.ghtg. Boxes-Enclosures-Panelboards4ns. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date 'Card B-1 Date Card B-1 O -Not OK Not Applicable Not Ready Date YJWERFLOOR (Plans) OK except RESIDENTIAL (Single & Duplex) It, jffj 12!Ftg., Main; Soils-Elec. Gmd.-/ P Ftg. Depth 3. Ftg. Garage; Soils-Steel-Elec. Gmd/ /" Ftg. Depth 4. Ftg._>c6es& Decks; SoilsSteel-/ /" Ftg. Depth 6eSlimwalls, Main;,Steel-Blockouts4Nrapped ELECTRICAL (Permit) OK except #'s 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 23. 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped Elec. Receptacles Spacing -Lights & Switches at Doors 8. Piers -Fireplace Ftg.-Steel 25. 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Romex Installed Close to Edge of Studs & C.J. 11. Water Pipe; Test -Anchors -Regulator -Service Test 27. 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 2 Appliance Circuts in Kitchen & Conductor Size GFI 14. Girders -Sills -Anchor Bolts -Joists Vents -Clippies 29. 15. Access & Ventilation 16. Insulation Range Circ. / / ga Cu or AI -Oven Circ. / / ga Cu or Al Insulated Neutral 0 Yes 0 No Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #s Clothes Closet Light -Shower Light -Spa Light 17. Water Htr.; Vent -Access -Combustion Air Baffle 34. 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access Date 22. Gas Pipe; Sixe & Anctiors Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mech Fastners-Bond Gas & Water 28. 2 Appliance Circuts in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or Al 30. Range Circ. / / ga Cu or AI -Oven Circ. / / ga Cu or Al Insulated Neutral 0 Yes 0 No 31. Service -Riser Conductors & Ground -Main Disconect 32. Equip. Clearances Panels -Motors -Meth. Epuip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35. A.C. Ducts Insulation & Support 36. Vent Fan, Exhaust above insulation 37. Condensate Drain & Overflow, Size & Grade 38. Fumance-Vent Access -Comb. Air -Return Air Vent 115 outlet 39. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except #'s 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing Date FRAMING (Continued) - 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr: Ties-Purlin-roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3 -Check Garage 3rd Story, 2 Exits 54. Stairs; Width-Headroom-Rise-Rurrtanding-Fire Protection 55 Plywood on Roof Overhang -Attic Vents -Rafter Outriggers . Siding -Nailing Veneer �. . Stucco Mesh -Drip Screed -Fd. Vents-Underfir. Access ` 58. Glazing Area -Class Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior / Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1,-- Date Card B-1 Date Ca -1 Date Card B-1 Date AINAL "') OK except #'s t S -Door & Sidelight Protection -Landings moke Detector tor - In e; ecttrProtection %-11!5pting 6 . FI. & Bath Fixtures & Tub Access -Spa ne , rea er Sizes & Labels 69. is ea 71. ec. u e a ane , nt. & Ext. 72. Kit=F&I-&-Appffa7me'6ro - r a coking Clearance 73. e s a i. ounter Firc-Boor,-SW s re 75. A.C. D�aGa r -JD(triitf • VentsSlearance-Comb. Air Connector-P.R.V. In ra F1aerMe o ec on 77. Plb., Elec. & Mech_E up. Listed for Location 78 mex Protection 79." nsu ation- oam- in c --89-6aardreils8� s_ 81. "Inan.Nben s ra Hole oor rainage & Wood -Earth Clearance Looked under Floor Yes 82. Fol ng Instid./Ddve 0 Yes 0 NoNValks 0 Yes 0 No/Planters 0 Yes 0 No eje*Stucco Brown -Finish ni isconnect, Electrical -Plumbing 85. g- p lance fireplace -Clearance to Openings 86. Wa1erJA! ing 87. Ext c e- nderground s Protection 90. Corrections fromT7Inspections as es - ers agg G59 -Electric 92, Water r onnect a D Approval &eofn-ergy Compliance Certificate -Other Certificates Date Ca 8-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: _ COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES - BUILDINGDIVISION v 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541PERMIT NO. (Rev. 1.2/96) APPLICATION AND PERMIT q7 -a6 Z-lq- ASSESSOR PARCEL NUMBER 0-370-011 ZONING BUILDING PERMIT OWNER AND BARBARA WILLITS TELEPHONE 892-8154 SO. Fr. OCC. BUILDING VALUATION OWNERSRUSTY MA o `Y�"ESTATES DR. CHICO 276 + 904.00 60 C 780.00 CONTRACTOR'S NAME RUSS COLLAR TEL��j4j(C�NE 3055 g gooF 21.8 3,815.00 4.8 BUILTUP 624.00 CONTRACTORS MAIUNG ADDRESS 4425 WILLOW SPRINGS RD CHICO CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $ 20.123.00* ARCHITECT OR ENGINEER TTM CRRTR LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 216.00 ARCHITECT OR ENGINEERS NOCAILING ADDRESS Plan Checking Fee $ 140.40 BUILDING ADDRESS Energy Plan Checking Fee $ 23.00 PERMIT FEE $ 394.40 LOT NO. 47 SUBDIVISIONS NAME BUTTE CREEK SUB. #1 PARCEL MAP PLUMBING PERMIT Filing Feel 20.00 USEOFSTRUCTURE SF Ik Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap7.00 Solar or heat um water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: MASTER BEDROOM/LAUNDRY Gas i in system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home ISI GI W1 @20.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service ODDV OR LESS 200A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter • 9 (commencing with Section 7000) of Division 3 of the Business and Pr essions Code, and my license is in full f fce and effect. �{ �/ License Class Lic. No. �(/ �9' WNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO ,oDDA 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( a ACC. BLDS. S 3.5¢FTO. NEW CONST. MULTI.OUTLET NON•RESID. ANC @7.50 POWER APPARATUS 8 SINGLE OUTLET CIR. Ex. OCCU . OUTLET OR FDMRES SAl Q,.50 LNS Ex. Occup. olFir�iErs RES D.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE _ ' WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 1011", have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' cArryo sa i In ins�Ferl) cayr. and policy number are: Carrier --) �J/til� ,`� j� Policy Num er P (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply."Math those provisions. �y X ___ Date _ s/�� _ Signature of Applicant - Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in heig t. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEI: $ Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ PE TOTAL FEE $ 510.05 ±HAZ.D. EES IMP F OD CDF PARCEL pD HD SUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have - A By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. �e- ate l �. % �cQ7 Date Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSES OR PINK-INSP&CTOR GOLDENROD -APPLICANT ' ? . + . , � r r�i� ,A � ` '�,� � � J..�,r� �E1 �,?' �`�+, +;`Ma �" \� `�'`4?'ti"`•` r::�'-��%t.1..rr,.;,w�'"',.a.;:a��Y� . ?o-���'u,:±�h.iT'�•��",;:w,ri G 1. �tir'➢i �•. 1 � J �, � •f..' � �.-..y� ��.r } �' � P rNAt # COUNTY,1W BUTTE DEPARTMENT OF DEVELOPMENT"SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541. SCHEDULE OF FEES DUE OWNER i—hi PROPOSED BUILDING USE sle 1. BUILDING PERMIT FEES -- Balance Due ................ $ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES / Gy (paid at District Office) 3. SHERIFF FEES (paid at Building Division) Residential ....:... x $360.00 = $ t� `�' ""• ' Units Commercial (sq.ft.)... x $0.03 = $ • Sq.Ft. 7 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x = $ #Units • Amt. f r Commercial (sq.ft.) .. x =$ A.P. # 0 7e — O// DATE REC # DATE REC Sq.Ft. Amt. �. 5. RECREATION DISTRICT FEES w (paid at at District Office) ' 6. THERMAL'ITO DRAINAGE DISTRICT FEES $425.00 (paid at Building Division) Aj rr 7: SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) - 8. WATER TENDER FEES (Battalion # ) =- $200.00 -(paid at Building Division) r 9. ,CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These feesm y be changed during the plan checking process. APPLICANT DATE Original -Owner Copy -Building Div. (Rev. 12/96) I I • LINTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. w.t2/96} APPLICATION AND PERMIT SSESSOR PARCEL NUMBER 2ON'"O BUILDING PERMIT IWNER �f — 7EUFYNONE c%/SWI/ ►� � ANN 1X56 D� :ONTRACTOR'S NAME TELEPHONE mss C.oZt - q(IRE 3 :ONrRACTOMA CJD A�Q �Bi 5 �, S W, bra INSTRUCTION LENDER INDER'S MMUNO ADDRESS OACMMECT OR ENGINEER -{ rrANSE NO. ARCHITECT OR EWMEMS MAILING- ADDRESS BUiLDINO ADDRESS � OA- LOT NO. G�/ I BUBDrm1oN C.. 1 PARCEL MAP / go ` SF ® Dupiex O Mobilehome O Other svEcln SO, FT. I OCC. I BUILDING VALUATION Fireplace /v o Total Valuatlon $ Filing Fee Permit Fee a�G Plan Checking Fee / 4G0 , (LD Energy Plan Checking Fee PERMIT FEE PLUM13ING PERMIT Each Trap Solar or heat pump water heater Water piping TYPE OF WORK Gas piping system 1 - 5 outlets New O Addition Ll Remodel O Utilities Q Installation O Other O Building sewer ,/1,, �,, •t' I / Mobile Home I S G W Describe Work: LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. b License Class B Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law tot the following reason: O I. as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. O I, as owner of the property. am exclusively contracting with licensed contractors to construct the project. O 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: O 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code. for the -dormance of the work for which this permit is issued. V"'Iphnve and will maintain workers' compensation insurance. as required by Section II 3700 of the Labor Code, tot the performance of work for which this permit is issued. A�w My workers' compensation i urenc carrier and policy number are: �.- Carrier 1I1� Policy Number 97 (The above sections need not be completed it thi perm) is for work of a valuation of one hundred dollars ($100) or less.) O 1 certify that in the performance of the work for which this permit is issued. 1 shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with th/oprovisions. X _���J./Date gnatu Sire o' f�licant - O Owner Contractor O Agent An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. Receipt No. T. PERMIT FEE s ELECTRICAL PERMIT LE Main $efVICB aooAeoov OR OR lEBSSS Main Service ]DOA TO I—A , fling Fee 7.00 23.00 15.00 15.00 15.00 1 S.00 (IR20.00 20.00 Fee 20.00 23.00 3 EX. Occup. OUTLET OR FIXTURES BAL " .so Ex. Occup.OVILIFTS CREFiXED ra o a 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc.^Wirin =+ 23.00 PERMIT FEE _ MECHANICAL PERMIT f=iling Fee 20.00 Heating __> &Lekpiad_ 6.50 PERMIT FEI! S .O Mobile Home Inst4liation Fee Energy Inspectio Fee , $ `OM TOTAL FEE S HA2 O. FEES RAP 1 FT I D PARCEL PO ND SUE r � Y This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON owo) COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER (f �y i y2,Qv ,� (,,y�// iTl ASSESSOR PARCEL q6 -� 70 Proposed Building Use: S /tiG Building Inspector: Date: l?'- Z Q'7 At time of permit applicatio , I was advised the following data must beub eed prior to permit processing and/or issuance: Date Received By All items have been submitted -------------------------------------------------------------------------------------- 02. Plot plans, 3/4 sets, signed by the preparer of plans. ------------------------------------------------------------ ❑ 3. Complete plans, 3/4 sets, signed by the preparer of plans. ----------------------------------------------------- 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ 116. ----------------- ❑6. Energy Design Compliance and supporting documentation. ---------------------------------------------------- r ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. --------------------------------------------------------- ❑ 8. Hazardous Material Form.------------------------------------------------------------------------------------------ ❑9 anufactured Home data and installation instructions including Tie Down Specifications .---.-------------- 10. Fees of $ t9, /V------------------------------------------------------------ - =L1Y ) 1-------- Jul . Impact fees as shown on the attached schedule. ---------------------------------------------------------------- ❑ 12. ;lood ifornia Department of Forestry pleval/fees. --------------------------------------------------------- 3. elevation certificate. ------- .� --------------------------------------------------- Sanitation and plot plan approvalCHealth Department. ------------------------------------------- ❑ 15. City of Chico plumbing permit.----------------------------------------------------------------------------------- ❑ 16. Plot plan and business license approval from the City of Biggs ❑ 17. Planning approval for (A) Use: (B) Parking: 1:118. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ----------------------- 1119. ---------------------- ❑19. Encroachment Permit for driveway (construction approval prior to occupancy). ---------------------------- 020. Pre -inspection for required Request to Building Inspector on (Date) ❑21. Contractor's license information. (Number, Name Style, Classification). ------------------------------------ 022. Workers' Compensation carrier and policy number.----------------------------------------------------------- ,u ❑23. Owner -Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- i ❑24. Letter of signature authorization. -------------------------------------------------------------------------------- ❑25. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- 1126. ------------------------------------------------- ❑26. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing violations and/or expired permits.---------------------------------------------------------------------- ❑29. ❑433 A, []Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ .--------------- E130. -------------- ❑30. Other: When you issue the permit, process as follows ❑ Mail to owner, ❑Mail to contractor. OTelephone and hold for pickup at o ce.Xn�7 ector. Applicant: Date: Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Qppganw4t, ❑ Air Pollution Date-,' By: Copy of plans sent ❑ Health Department, ❑ Fire Departm the : By: 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above data ❑phone, ❑mail; ❑Building ivision counter, by Date: Contractor, designer, owner, was advised of the above required data b ❑ phone, ❑ mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division.counter, by Date: Contractor, designer, owner, was advised of the above required data by o phone, ❑ mail, ❑ Building Di ision counter, by Date: Plans reviewed by: Date: Plans approved by: Date: Sets of plans on hold in ❑ Plan Cabinet, o A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. J U E.H. USE ONLY / Plot Plan Attached J - Floor Plan Attached y Sent to B.D. TO: Building Department FROM: Environmental Health ' SUBJECT: Sanitation Clearance Rus�fy V1,111±5 ISS Es it.S nlr• .40- 370-011 Owner Location AP# Plan Approved for: Sewage Disposal -,X' Water Supply: Public Private Well Clearance fordweHia: Other Sr'A7°jj 6(re4 eLISC:t- ta-eV-1'5-i'ft4 64rv1114-t as Axwx ox JD/eats . Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist 8/96 9- 23 —97 Date FLOOD PLAIN DECLARATION 4 I declare the actual value of the proposed construction work under building permit . application number: at the location of Assessor Parcel Number: AL2 -?,?D' o for the construction of an addition for bZGQa P�G4-t��'j does not equal or exceed the'definition. of "Substantial Improvement I am aware the building site is in a flood - plain area, even though I am not required to comply with the flood plain management criteria. Property Owner: �,L , G✓/L�� /� Address: PhoneNumber: fL -ori s7' Date: Substantial improvement is defined as follows: Any repair, reconstruction, orimprovement of a.... structure, the cost equals or exceeds 50% of the market value of the structure either, (a) before improvement or repair is"started or (b)' if the structure has been damaged; and is being restored; before the damage occurred. NOTE: Documentation may be required to substantiate cost. wp gfi STEP 121N 6IN -R CLST AN SITTING AREA ' 24F- V4 3 1/8- X 12 GLB 2-6 -- --' RELOCATE.'(SE) PR ; 2-& FR .T(j ADJACE Y:.... • .. , ; .. . WALL• ' ' ' - :: .22 5-0 BF 3- . REMO _ 2X6 CJ (E) DR AT 16 IN 2X2 E BATH OAC AFTERS AT 24 IN BEARING WALL F LAL�= ( j ��! L. ROOF W► fir! S i )'L!7 AND PER WN E --4ROV Vjr0nmentat liealth County :nvronmental H 2 2 1997 Date , Caiifomia Signature NT �o �x J X N 0 o \v I=-. IZ Qp g' PtJ�uc vT�t.�TY. QA�C`M�NT �• ' 4or fal l�ealf� SEP 2 2 199, riga AOR991emia . utte County Envi onmental Health Date 'gnature o�An r -I 19,1if, " A } I 'fit Z co✓Q Ea c, =c T- 010 fc,Xfo.�A'A or - L ,o-s(r 4 i N �1 1 �� %�I v 1 WAS IiWAIN- 4Gp1�� i 4441 co c: -,g . AM 4o *3'70,�'-01 1 I zv!jrY46WeAe-4 wiuAII�;F. ADDITION WORKSHEET Page 1 ADD Project Title.......... The Willits Addition Date........ 09/17/97 Project Address........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Building Permit Energy Calculation Services 1907 Mangrove Avenue, Suite D Plan Check Date Chico, CA 95926 916-894-8466 Fie C ec Date Climate Zone ........... 11.- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by.Enercomp, Inc. MICROPAS4 v4.50 File-97208EX Program -ADDITIONS User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition ADDITION WORKSHEET - COMPUTER PERFORMANCE EXISTING File Name .................. 97208EX Run Title .................. 1180 SF Existing Res. Conditioned Floor Area..... 1180 sf Standard Design Energy Use. 46.97 kBtu/sf-yr Proposed Design Energy Use. 149.76 kBtu/sf-yr NEW (EXISTING PLUS ADDITION) File Name .................•.. 97208ADD Run Title .................. 1456 SF Existing+Addition Conditioned Floor Area..... 1456 sf Standard Design Energy Use. 43.66 kBtu/sf-yr Proposed Design Energy Use. 100.87 kBtu/sf-yr FLOOR AREA RATIO Floor Existing New Area Floor Area Floor Area Ratio 1180 / 1456 = 0.810 ADDITION DESIGN ENERGY USE FOR NEW (EXISTING PLUS ADDITION) Floor New Area Existing Existing Addition Standard Ratio Proposed Standard Design 43.66 + 0.810 x ( 149.76 46.97) = 126.97 Note: If (Existing Proposed - Existing Standard) is negative, this difference is set to zero. ADDITION ENERGY USE SUMMARY Energy Use Addition Proposed (kBtu/sf-yr) Design Design New .................... 126.97 100.87 *** Addition complies with Computer e Compliance Margin 2.10 ii<ir�a b CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... The Willits Addition_ Date........ 09/17/97 Project Address........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Building Permit Energy Calculation Services 1907 Mangrove Avenue, Suite D Plan Check Date Chico, CA 95926 916-894-8466 Field Check/ Date Climate Zone .. ..... . 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition GENERAL INFORMATION Conditioned Floor Area..... 1456 sf Building Type .............. Single Family Detached Construction Type ......... Existing Plus Addition Building Front Orientation. Front Facing 90 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Raised Floor Glazing Percentage......... 19.6 0 of floor area Average Glazing U -value.... 0.59 Btu/hr-sf.-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R -value R -value R -value U -value Location/Comments Wall n/a R-0 R-n/a R-0 0.386 FRONT, TO GARAGE LEFT, BACK, RIGHT Door n/a R-0 R-n/a R-0 0.330 ENTRY, TO GARAGE Wall n/a R-13 R-n/a R-13 0.088 LEFT, BACK, BACK -LEFT BACK -RIGHT, RIGHT Roof n/a R-19 R-n/a R-19 0.049 TO ATTIC Roof n/a R-30 R-n/a R-30 0.031 TO ATTIC Floor n/a R-0 R-n/a R-0 0.101 RAISED FLOOR Floor n/a R-19 R-n/a R-19 0.037 RAISED FLOOR FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (E) 16.0 0.600 2 Drapes.Std None None Vinyl Window Front (E) 16.0 0.600 2 Drapes.Std None None Vinyl Window Front (E) 9.0 0.600 2 Drapes.Std None None Vinyl Window Front (E) 35.0 0.600 2 Drapes.Std None None Vinyl Window Left (S) 9.0 0.600 2 Drapes.Std None None Vinyl Door Left (S) 40.0 0.550 2 Drapes.Std None None Wood Window Back (W) 12.0 0.600 2 Drapes.Std None None Vinyl Window Back (W) 40.0 0.600 2 Drapes.Std None None -Vinyl Window Back (W) 24.0 0.600 2 Drapes.Std None None Vinyl Window Back (W) 40.0 0.600 12 Drapes.Std None None Vinyl Window Left (SW) 6.8 0.570 2 Drapes.Std None None Vinyl Window Back (W) 20.3 0.600 2 Drapes.Std None None Vinyl Window Back (NW) 6.8 0.570 2 Drapes.Std None None Vinyl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... The Willits Addition Date........ 09/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition FENESTRATION , ..,, rt . - ____ # of-Intexior. Area U- Pan- Shading/ Orientation (sf) Value es Description Window Right (N) 6.0 0.600 2 Drapes.Std Window Right (N) 4.0 0.600 2 Drapes.Std Attic R-2.1 HVAC SYSTEMS .. ..._,.....__.._.Over.- .� ,....._... Exterior hang/ Framing Shading Fins Type None None Vinyl None None Vinyl Tank Type Storage Thermostat Type Setback Setback Setback Setback Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value Gas Standard 1 .53 EF 40 R-0 SPECIAL FEATURES/REMARKS All energy values for the existing building are from Table 7-2; Default Energy Values for Existing Building built before 1978. Energy enhancements to the existing house include the installation of a new HVAC unit in 1988 and Vinyl framed replacement windows. Minimum Duct Duct Equipment Type Efficiency Location R -value Gas 0.780 AFUE Attic R-2.1 AirCond 8.90 SEER Attic R-2.1 Gas 0.780 AFUE Attic R-4.2 AirCond 8.90 SEER Attic R-4.2 WATER HEATING SYSTEMS Tank Type Storage Thermostat Type Setback Setback Setback Setback Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value Gas Standard 1 .53 EF 40 R-0 SPECIAL FEATURES/REMARKS All energy values for the existing building are from Table 7-2; Default Energy Values for Existing Building built before 1978. Energy enhancements to the existing house include the installation of a new HVAC unit in 1988 and Vinyl framed replacement windows. .y t CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... The Willits Addition__ Date........ 09/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM CF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition COMPLIANCE STATEMENT This- certificat.e_._o.f....compliance lists, .the- building feat.ures..and,.performance—.- specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. when this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Tim Crete Company. Architect Address. Phone... Licens Sig d. Name.... Title... Agency.. Phone... Signed.. DOCUMENTATION AUTHOR Name.... Marty Runnells Company. Energy Calculation Services Address. 1907 Mangrove Avenue, Suite D Chico, CA 95926 Phone... 916-894-8466 to MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... The Willits Addition Date........ 09/17/97 ProjectAddress........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Energy Calculation Services 1907 Mangrove Avenue, Suite D Chico, CA 95926 916-894-8466 Climate Zone........... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specif.ications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. Building Permit Plan Che -c Date Fie C ec Date Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specif.ications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b) Loose fill insulation manufacturers labeled R -Value. *150(c) Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). ✓ *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.30, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form.. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. w a 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. N MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1R Project Title.......... The Willits,Addition Date........ 09/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM MF -1R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES IIesign.- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. ✓ 150(i): Setback thermostat on all applicable heating systems. � A 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between.heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. ,, 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. N/A 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have -..no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). P A LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page 1 C -2R Project Title.......... The Willits Addition Date........ 09/17/97 Project Address........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Bui ing Permit Energy Calculation Services 1907 Mangrove Avenue, Suite D Plan Check Date Chico, CA 95926 916-894-8466 Field Check/ Date Climate Zone. Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM C -2R . User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area....;... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1456 sf Single Family Detached Existing Plus Addition Front Facing 90 deg (E) 1 1 ReducedYear Raised Floor 2 11648 cf 1456 sf 1456 sf 0 sf 19.6 % of floor area 0.59 Btu/hr-sf-F 8 ft BUILDING ZONE INFORMATION MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 13.71 41.49 -27.78 Space Cooling.......... 15.48 43.46 -27.98 Water Heating.......... 14.47 15.92 -1.45 (sf) Total 43.66 100.87 -57.21 *** Building does not comply with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area....;... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1456 sf Single Family Detached Existing Plus Addition Front Facing 90 deg (E) 1 1 ReducedYear Raised Floor 2 11648 cf 1456 sf 1456 sf 0 sf 19.6 % of floor area 0.59 Btu/hr-sf-F 8 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) EXISTING Residence 1180 9440, 0.81 Yes Setback 2.0 n/a ADDITION Residence 276 2208 0.19 Yes Setback 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... The Willits Addition Date........ 09/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition OPAQUE SURFACES _,Ar.ea._ ...U- .__Insul Act Solar ._ . _. Form 3 .,..-Location/ .__... Surface (sf) value R-val Azm Tilt Gains Reference .. Comments EXISTING - Existing 1 Wall 288 0.386 0 90 90 Yes None FRONT 2 Wall 142 0.386 0 90 90 No None TO GARAGE 3 Door 20 0.330 0 90 90 Yes None ENTRY 4 Door 18 0.330 0 90 90 No None TO GARAGE 5 Wall 127 0.386 0 180 90 Yes None LEFT 6 Wall 104 0.386 0 180 90 No None TO GARAGE 8 Wall 244 0.386 0 270 90 Yes' None BACK 12 Wall 230 0.386 0" 0 90 Yes None RIGHT 14 Roof 1180 0.049 19 n/a 0 Yes None TO ATTIC 16 Floor 1180 0.101 0 n/a 0 No None RAISED FLOOR ADDITION - Existing 7 Wall 56 0.088 13 180 90 Yes None LEFT 9 Wall 132 0.088 13 270 90 Yes None BACK 10 Wall 17 0.088 13 225 90 Yes None BACK -LEFT 11 Wall 17 0.088 13 315 90 Yes None BACK -RIGHT 13 Wall 96 0.088 13 0 90 Yes None RIGHT 15 Roof 276 0.031 30 n/a 0 Yes None TO ATTIC 17 Floor 276 0.037 19 n/a 0 No None RAISED FLOOR FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface .(sf) es Type Type value Azm Tlt Only Shade Description EXISTING - Existing 1 Window 16.0 2 Vinyl Slider 0.600 90 90 0.88 0.78 Drapes.Std 2 Window 16.0 2 Vinyl Slider 0.600 90 90 0.88 0.78 Drapes.Std 3 Window 9.0 2 Vinyl Slider 0.600 90 90 0.88 0.78 Drapes.Std 4 Window 35.0 2 Vinyl Slider 0.600 90 90 0.88 0.78 Drapes.Std 5 Window 9.0 2 Vinyl Slider 0.600 180 90 0.88 0.78 Drapes.Std 7 Window 12.0 2 Vinyl Slider 0.600'270 90 0.88 0.78 Drapes.Std 8 Window 40.0 2 Vinyl Slider 0.600 270 90 0.88 0.78 Drapes.Std 9 Window 24.0 2 Vinyl Slider 0.600 270 90 0.88 0.78 Drapes.Std 10 Window 40.0 2 Vinyl Slider 0.600 270 90 0.88 0.78 Drapes.Std 14 -Window 6.0 2 Vinyl Slider 0.600 0 90 0.88 0.78 Drapes.Std 15 Window 4.0 2 Vinyl Slider 0.600 0 90 0.88 0.78 Drapes.Std ADDITION - Existing 6 Door 40.0 2 Wood Hinged 0.550 180 90 0.88 0.78 Drapes.Std 11 Window 6.8 2 Vinyl Fixed 0.570 225 90 0.88 0.78 Drapes.Std 12 Window 20.3 2 Vinyl Slider 0.600 270 90 0.88 0.78 Drapes.Std 13 Window 6.8 2 Vinyl Fixed 0.570'315 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page 3 C-2R Project Title.......... The Willits Addition Date... ... 09/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition Tank Type 1 Storage Duct HVAC SYSTEMS _.. _.._. ..Minimum _ Duct System Type Efficiency Location EXISTING R-4.2 0.810 Gas 0.780 AFUE Attic AirCond 8.90 SEER Attic ADDITION Gas 0.780 AFUE Attic AirCond 8.90 SEER Attic WATER HEATING SYSTEMS Tank Type 1 Storage Duct _ __.D.uc.t R -value Efficiency R-2.1 0.780 R-2.1 0.740 R-4.2 0.830 R-4.2 0.810 Number Tank in Energy Size Heater Type Distribution Type System Factor (gal) Gas Standard 1 .53 40 SPECIAL FEATURES/REMARKS All energy values for the existing building are from Table 7-2; Default Energy Values for Existing Building built before 1978. Energy enhancements to the existing house include the installation of a new HVAC unit in 1988 and Vinyl framed replacement windows. External Insulation R -value HVAC SIZING Page 1 HVAC Project Title........ The Willits Addition Date........ 09/17/9.7 Project Address........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Building Permit Energy Calculation Services 1907 Mangrove Avenue, Suite D Plan Check Date Chico, CA 95926 916-894-8466 Field Check/ Date Climate Zone....... .... 11 Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -HVAC SIZING User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition GENERAL INFORMATION Floor Area ................. Volume ..................... Front Orientation.......... Sizing Location............ Latitude ................... Winter Outside Design...... Winter Inside Design....... Summer Outside Design...... Summer Inside Design....... Summer Range ............... Interior Shading Used...... Exterior Shading Used...... Overhang Shading Used...... Latent Load Fraction ........ Description 1456 sf 11648 cf Front Facing 90 CHICO EXP STA 39.7 degrees 27 F 70 F 102 F 78 F 37 F Yes Yes Yes 0.20 HEATING AND COOLING LOAD SUMMARY deg (E) Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 29000 12804 Glazing Conduction ............... 7247 4045 Glazing Solar .................... n/a 10482 Infiltration ..................... 7366 2420 Internal Gain .................... n/a 2100 Ducts ............................ 4361 3185 Sensible Load .................... 47973 35036 Latent Load ...................... n/a 7007 Minimum Total Load 47973 42044 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. HVAC SIZING Page 2, HVAC Project Title...... The. Willits -Addition Date........ 09-/17/97 MICROPAS4 v4.50 File-97208ADD Wth-CTZ11S92 Program -HVAC SIZING User#-MP1333 User -Energy Calculation Servic Run -1456 SF Existing+Addition HEATING AND COOLING LOAD SUMMARY BY ZONE ZONE 'EXISTING' Floor Area ....................... 1180 sf Volume ........................... 9440 cf Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain.................... Ducts............................ Sensible Load ..................... Latent Load ...................... Minimum Zone Load ZONE 'ADDITION' Heating (Btuh) 26989 5444 n/a 5969 n/a 3840 42242 n/a 42242 Floor Area..... .................. 276 sf Volume ........................... 2208 cf Heating Description (Btuh) Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar .................... Infiltration ..................... Internal Gain .................... Ducts ............................ Sensible Load.................... Latent Load ...................... Minimum Zone Load Cooling (Btuh) 11803 3038 8464 1962 1701 2697 29665 5933 35599 Cooling (Btuh) 2011 1001 1803 1006 n/a 2018 1396 459 n/a 399 521 488 5731 5371 n/a 1074 5731 6445 COMPUTER METHOD SUMMARY Page 1 C -2R Project Title........ The Willits Addition Date...... 09_/17/97. Project Address........ 152 Estates Drive ******* Chico *v4.50* Documentation Author... Marty Runnells ******* Building Permit Energy Calculation Services 1907 Mangrove Avenue, Suite D Plan Check Date Chico, CA 95926 916-894-8466 Field Check/ Date Climate_ Zone.......„.............. 11.,.. Compliance Method...... MI v4.50 for 1995 Standards by E P nercomp, Inc. MICROPAS4 v4.50 File-97208EX Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Servic Run -1180 SF Existing Res. GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area............. Ground Floor Area.... .... Slab -On --:Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1180 sf Single Family Detached Existing. Front Facing 90 deg (E) 1 1 ReducedYear Raised Floor 1 9440 cf 1180 sf 1180 sf 0 sf 21.3 0 of floor area 1.19 Btu/hr-sf-F 8 ft BUILDING ZONE INFORMATION Floor Area Volume Zone Type (sf) (cf) EXISTING Residence 1180 9440. # of Dwell Cond- Thermostat Units itioned Type 1.00 Yes Setback Vent Special Height Vent Area (ft) (sf) 2.0 n/a MICROPAS4 ENERGY USE SUMMARY Energy Use Standard Proposed Compliance (kBtu/sf-yr) Design Design Margin Space Heating.......... 13.83 61.65 -47.82 Space Cooling.......... 16.43 69.59 -53.16 Water Heating.......... 16.71 18.52 -1.81 Total 46.97 149..76 -102.79 *** Building does not comply with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area............. Ground Floor Area.... .... Slab -On --:Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... 1180 sf Single Family Detached Existing. Front Facing 90 deg (E) 1 1 ReducedYear Raised Floor 1 9440 cf 1180 sf 1180 sf 0 sf 21.3 0 of floor area 1.19 Btu/hr-sf-F 8 ft BUILDING ZONE INFORMATION Floor Area Volume Zone Type (sf) (cf) EXISTING Residence 1180 9440. # of Dwell Cond- Thermostat Units itioned Type 1.00 Yes Setback Vent Special Height Vent Area (ft) (sf) 2.0 n/a COMPUTER METHOD SUMMARY Page 2 C -2R Project Title.......... The, Willits Addition Date........ 09/17/97 MICROPAS4 v4.50 File-97208EX Wth-CTZ11S92 Program -FORM C -2R User#-MP1333 User -Energy Calculation Servic Run -1180 SF Existing Res. Form 3 - Location,/ -Reference Comments None FRONT None TO GARAGE OPAQUE SURFACES None �^ Area LEFT .Insul Act None Solar Surface (sf) value R-val Azm Tilt Gains EXISTING - Existing Shading/ Surface (sf) es Type 1 Wall 288 0.386 0 90 90 Yes 2 Wall 142 0.386 0 90 90 No 3 Door 20 0.330 0 90 90 Yes 4 Door 18 0.330 0 90 90 No 5 Wall 127 0.386 0 180 90 Yes 6 Wall 104 0.386 0 180 90 No 7 Wall 388 0.386 0 270 90 Yes 8 Wall 230 0.386 0 0 90 Yes 9 Roof 1180 0.049 19 n/a 0 Yes 10 Floor 1180 0.101 0 n/a 0 No Form 3 - Location,/ -Reference Comments None FRONT None TO GARAGE None ENTRY None TO GARAGE None LEFT None TO GARAGE None BACK None RIGHT None TO ATTIC None RAISED FLOOR FENESTRATION SURFACES HVAC SYSTEMS Minimum: Duct System Type Efficiency Location EXISTING Gas 0.750 AFUE Attic AirCond 8.00 SEER Attic Duct Duct R -value Efficiency R-2.1 0.780 R-2.1 0.740 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 .53 40 R-0 # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description EXISTING - Existing 1 Window 16.0 1 Metal Slider 1.190 90 90 1.00 0.88 Drapes.Std 2 Window 16.0 1 Metal Slider 1.190 90 90 1.00 0.88 Drapes.Std 3 Window 9.0 1 Metal Slider 1.190 90 90 1.00 0.88 Drapes.Std 4 Window 35.0 1 Metal Slider 1.190 90 90 1.00 0.88 Drapes.Std 5 Window 9.0 1 Metal Slider 1.190 180 90 1.00 0.88 Drapes.Std 6 Window 12.0 1 Metal Slider 1.190 270 90 1.00 0.88 Drapes.Std 7 Window 40.0 1 Metal Slider 1.190 270 90 1.00 0.88 Drapes.Std 8 Window 24.0 1 Metal Slider 1.190 270 90 1.00 0.88 Drapes.Std 9 Window 40.0 1 Metal Slider 1.190 270 90 1.00 0.88 Drapes.Std 10 Window 40.0 1 Metal Slider 1.190 270 90 1.00 0.88 Drapes.Std 11 Window 6.0 1 Metal Slider 1.190 0 90 1.00 0.88 Drapes.Std 12 Window 4.0 1 Metal- Slider 1.190 0 90 1.00 0.88 Drapes.Std HVAC SYSTEMS Minimum: Duct System Type Efficiency Location EXISTING Gas 0.750 AFUE Attic AirCond 8.00 SEER Attic Duct Duct R -value Efficiency R-2.1 0.780 R-2.1 0.740 WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 .53 40 R-0 t COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... The. Willits.._Acldition Date........ 09/17/.97 MICROPAS4 v4.50 File-97208EX Wth-CTZ11S92 Program -FORM C- 2R User#-MP1333 User -Energy Calculation Servic. Run -1180 SF Existing Res. SPECIAL FEATURES/REMARKS All ..energy. value s...for ...the,. exist ng...,b.u- l.ding are from.Table Default Energy Values for Existing Building built before 1978. Energy enhancements to the existing house include the - installation of a new HVAC unit in 1988 and Vinyl framed replacement windows. School District A.P. Number Property Owner BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM" - (One form per Building) Building Department No. �tJ ` 3 `%d '61Jurisdiction:City E2' County Property Location/Address �Z G• S'i �I~ %��'j' T% K_ Subdivision Residential Development No of Living Mobile Home. Units Installation Commercial/Industrial • New x Building D Lot No. Sq. Footage on 76 Addition (Group R) Sq. Footage Addition (Including Exterior Roofed Areas) Date ' wwor rians revieweD Dy acnooi uismct rersonneu ,District Identification No. School District certifies that P� %'� �.(� "0 ,r-- - (Applicant) wc, 0_• (Street Address) (Phone Number) G (City) (State) (Zip Code) has complied with the requirements of Resolution No. representing / square feet. School -District Paid by Check # / Vr� Remarks: „w L5/? -96 by payment of $ IFBi2926 $ ULL MITIGATION $ Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days'from the date fees are paid. Failure�to submit a timely written protest will prohibit you from challenging the Imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (2/977m dye ' COUNTY OF BUTTE BUILDING DIVISION Y DEPARTMENT OF DEVELOPMENT SERVICE9111 411 Main Street, Chico, CA - (916) 891-1751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE tvac-17 S y'7_76y OWNER PERMIT A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. '/) ,AAv 13A7F10(L9- L,dq COv'4'fZ k� Ar ' Date /U Z "`7 Inspector REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. 4/ Ail - Date Inspector Ni REV 10192 INSULATION CERTIFICATE 152 ES+a+_e s urn or and Street ount Description of Installation 1. ROOF Material Thickness (inches) 2 3. .: 4. 5 4 ty uuuivision Brand Name Thermal Rosistanco (R-Valuo) CEILING Batt or Blanket Type Fiberglass Batts. Brand Name Schuller Tnt. Thickness (inches) in -as " Thermal Resistance (R-Valuo) 1,30 Loose Fill Type Fiberglass Brand Name Schuller Tnt. Contractor/s min installed weight/It' Ib Minimum thickness inches Manufacturer's installed weight per square foot to achieve Thermal Resistance (R-Valuo) EXTERIOR WALL Frame Typo A. Cavity Insulation Material Fiberglass Batts Brand Name Schuller Tnt. Thickness (inches) 3.5" Thermal Resistance (R-Valuo) 3 B . Exterior Foam Sheathing Material Brand Name Thickness (inches) Thermal Resistance (R -Value)' RAISED FLOOR Material Fiberglass Batts Brand Name Schuller Tnt. Thickness (inches) Thermal Resistance (R-Valuo) SLAB FLOOR/PERIMETER Material Thickness (inches) Perimeter Insulation Depth (inches) FOUNDATION WALL Material Thickness (inches) Declaration Brand Name Thermal Resistance (R -Value) Brand Name Thermal Resistance (R-Valuo) IC -1 I hereby certify that the above insulatiun was installed in the building at the above location in conformance with the current E-neryy £lliciency Standards for residential buildings (Title 24, Part G, California Code of Regulations) as indicated on the Certificate of Compliance,dwhere a>rr>�licablo. LOIT E' INSULATION CO. , 1 -NC. P.O. Box 7927 C.L.14 9150 UChid CA. 95Q27 tem s ignature, ate 10-31�-� lnsta ing Subcontractor(Co.Name) General Contractor (Co. Name) OR Owner Item As—Signature, Date Item #S –Signature,- Date ns a1 inp u contractor lCo.Name) General Contractor (Co. Name) OR Owner nl sta1 ung Subcontractor(Co. ame R— General Contractor (Co. Name) OR Owner 61 Hk--. ENGINEERED WOOD SYSTEMS Certificate of .Conformance Certificate 19683 THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural wood products identified below and marked with a collective mark of American Wood Systems (AWS) were man- ufactured in accordance with the specifications indicated below. W ANSI Standard A190.1-1983, for Structural Glued Laminated Timber NER 267 a Prov;.loaded end loin;s Job Name GEORGIA PACIFIC CORPORATION SX-RAVIENTO , CA Job Location SAC -36130 072693 5643 Customer's Or- No. Date - Mfgr's Order No. �- 1/8 x '12 24f -v4 glulam beam Signature�, Title _ QudlitY Co:ltr'o 1 WatsoR Bohemia Inc. Vaughn, Oregon 072793 Company _ Address Date _ IT IS HEREBY CERTIFIED that the structural glued laminated timber production of the above-named manufacturer which carries a collective mark of American Wood Systems (AWS) is subject to regular audit by American Wood Systems, such audit consisting of the inspection with reasonable frequency of the manufacturing process, with adequate sampling to verify the quality of glulam construction and the adequacy of glue bond. 'VSnull// t1 . •.N..w�y I ' f`Or�tYQH,gr�..�t� SEAQ, ' .% y Michael R. O'Halloran Executive Vice President <� :� l(�- �� .. � �, �o " COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICA410N NID PERMIT l PERMIT NO. ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER iC: TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 1 -ti- CONTRACTOR'S NAME TELEPHONE X60 (11) CONTRACTOR'S MAILING -ADDRESS .l , A-. S] :) q r r - Fireplace CONSTRUCTION LENDER UNKNOWN 1 Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ 1 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 '2 .:.VV Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 10.00 ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation[] Other ❑ Describe work: r t --r- in- lio f ' f• 11. f Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 600V OR LESS Main service 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑NON.RESID 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business/POWER and Professions Code and my license is in full force and effect. y �`r o License No. Classification n ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ontract- ors.(Sec. 7044) ors. ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. / DWELLING OCCUP.N\ OR ADDNS. l ACC. BLDGS. / yzQsgft NEW CONSTR ULTI.OUTLET BRANCH CIRC ITS 2,50 ea APPARATUS e) (SINGLE OUTLET CIR. EX. OCCU o UTLETS OR FIXTURES 200500 1.200500 FIXED Ex. Occup. OUTLETS (RESID 1REA.) 1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ;❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. 1 C/.L:i� X �S'� ��1�- Date •• Signature of Applicant — Owner El Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ 2,-),,00 OCcu P. CONST.TYPC I I JFLO..JPARCE1J PD I ND I ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which fees DIRECTOR OF PUBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do have been paid. WORKS Date Receipt No. � WHITE-D.P.W.. YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO 7 County Center Drive - Oroville, Californ� 95965 - Telephone 916/534-45 3l� APPLICATION Ak PERMIT 01 / ASSESSOR PARC L`NUM� R YLQ I//n7 ZONING BUILDING PERMIT OWNER Michael Clark TELEPHONE 894-1777 SQ. FT. OCC, BUILDING VALUATION OWNER'S MAILING ADDRESS V 152 Estates Drive Chico 95928 q es p CONTRACTOR'S NAME Butte Roofin .Rany 1342-6553R TELEPHONE $400-00 CONTRACTOR'S MAILING ADDRE P.O. Box 557 Chico C Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ 10.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 152 Estates Drive Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF 91 Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 10.00 ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: reroof patio— hui 1 t ii 4 c Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 110.00 Main service 10001 OR LE 0 AMP ORLESS10.00 Main service EA. ADD•L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. 1a�5g Classification _Y77 ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUPM , OR ACDNS. ACC. BLDGS. /zQsgft NEW CONST R. RANCH C LET RCC 2.50 ea NO ESID BRANCH CIRC ITS POWER APPARATUS o- (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES 20®DOS DAL030 Ex. OCCup. OUTLETS P(RESID )FIXED APLNSREA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. 6yirin g 15.00 Permit Fee $ WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against s940 County Inc nseq a the granting of this permit. /�1 X /�+�.-:e_ (%'" Date 10/15/,.86 Signature of Applicant — Owner El Contractor ❑ AgentX An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ 20..00 OCGUP. CONST.TYPE "' I IFLOODIPARCELI PD I ND ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUB By PERMIT EXPIRES a e ,ZQ-� the applicable provi- resolutions to do fees have been paid. IC WORKS Date 7-,F7-2�� `— 79 Receipt No. WNITE-O.P.W.. YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDEN ROD -APPLICANT COUNTY OF rjUTTF DEPT. OF PUBLIC WORKS OCT 161986