HomeMy WebLinkAbout041-330-030a —
41=33-30 '�•, J!'/VI
dSpring Valley Minerals �<
mi-S.of Cherokee Rd., 2 mi. E.of Y M
Hwy 70
contr: Gary Le4r, Oroville, -r
(-.. Permit #1366-81P,Etil. MH
I! F
ELEC. 5-217-91 fSpA
r.� f
'GAS-- 8/ 7(8-
' SUPPORT STRUCTURE RQ. /7"
COMPACTION TEST REQ.
41-33-30 -
tr: Gary Ledger, Oroville
Per�"ii-int �k1367-81P,E(uti1. ,MH)
ELEC . - S/ /Slli �•
GAS
SUPPORT STRUCTUREZR�SZ.�., A _
! COMPACTION TEST REQ. /littj�e=lii '
41� i
0 LD
mierokee Rd, 2 mi E Hwy 70, Oro
Permi.
ed
f
41-33-30
Contr, Cal Gas
PermitM-86P(gas line/MH)
+ Per -
mitj# 86MHI
4
I
u
` - r
x`1-33-30'
61 Cherokee Rd, ORovil-le-�
I ; ermit#55-88MHI(exis ng site)
k"-
. . . . . . . . . . . .
PERMIT NO.
PERMIT EXPIRES
OWNER Spring Valley Minerals
CONTR. Gary Ledger, Oroville
ASSESSOR PARCEL 4.1-33-30
LOCATION SIS Cherokee Rd., 2 mi.E.of
Hwy 70
n
r
r
r
c
k
t
t
i
Temp. Power Pole
f
Called PG&E'
Temp. Elec. Service
Y
Called PG&E
Temp. Gas Service
Called PG&E
JOB FINALED (Date)
Signatu
�l
�a
� �
,y . - � .`
.` .�
t
r
. y
�
1
`�
'•
:' x
�"..
.' F.
_.
V = OK
0 = Not OK
- = Not Applicable = Not Ready RESIDENTIAL.(Sing.le and
Duplex)
Date
UNDERFLOOR Plans OK except #'s
Date
FRAMING (Continued)
1. Zoning requirements -Setbacks -Easements t
48.
Property Line Firewall & Openings
2.
3.
Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth
Ftg., Garage; Soils -Steel- / /" Ftg. Depth
49.
50.
Ext. Doors -One 3' -Check Garage -3rd story, 2 exits
Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
4.
Ftg., Porches & Decks; Soils -Steel- / /'' Ftg. Depth
51.
Plywood on Roof Overhang -Attic Vents -Rafter Outriggers
5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab
52.
Siding -Nailing -Veneer
6.
Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab
53.
Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access
7.
Piers -Fireplace Ftg.-Steel
54.
Glazing Area -Glass Protection -Skylights -Plastic
8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test
55.
Shear Walls; Nailing -Bolts
9. Gas Pipe; Size -Anchors
10.
11.
Water Pipe; Test -Anchors -Regulator -Service Test
Electric; Underground
12.
Plenums & Ducts; Clearance -Material -Support -Ins.
13.
Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FINAL (Plans) OK except #'s
56. Ext. Steps -Door & Sidelight Protection -Landings
Card -BI
Date
Date Card -BI Date
PLUMBING (Permit) OK except #'s
14. Water Ht.; Vent -Access -Combustion Air
57.
58.
Smoke Detector
Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor-Ducts-Mech. Protection
15. Water Pipe; Test & Anchors -Nail Protection
16.
D.W.V.; Test-Fttngs & Anchors -Nail Protection '
59.
Bedroom Exiting
17.
Shower Pan; Test, First Floor -Tub Access
60.
G.F.I. & Bath Fixtures & Tub Access
18.
Test Tub & Shower, 2nd Floor -Tub Access
61.
62.
Elec. Trim & Subpanel; Breaker Sizes -Labels
Stairs & Rails
19. Gas Pipe; Size & Anchors
63.
Fireplace or Stove; Clearances -Hearth
Card -BI
Date Card -BI Date
64.
65.
Elec. Outlets at Wood Panel; Int. & Ext.
Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance
Card -BI
Date Card -BI Date
66.
Elec. Outlets & Receptacles at Kit. Counter
Date
ELECTRICAL Permit OK except #'s
67.
Garage Fire Door; Swing -Landing -Closer
68.
A.C. Duct in Garage -Damper
20.
Fixture & Transformer Clearance -Ins. Protection
69.
Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.-
In Garage; Above Floor-Mech. Protection
21. Elec. Receptacles Spacing -Lights &Switches at Doors
22.
Size Boxes & No. of Conductors -Stapled
70.
Plb., Elec. & Mech. Equip. Listed for Location
23.
Romex Installed Close to Edge of Studs & C.J.
71.
Elec. Receptacles in Garage; (G.F.I.)-Romex Protec.
24.
Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water
72.
Insulation -Foam -Looked in Attic F) Yes
25.
2 Appliance Circuits in Kitchen &Conductor Size
Guard Rails & Deck Construction -Post Caps
26.
Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al
74.
Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance
Looked under Floor ❑ Yes
27.
28.
Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al,
Insulated Neutral ❑Yes El No
Service -Riser Conductors & Ground -Main Disconnect
75.
76.
Following instld.: Drive El Yes ❑ No; Walks ❑ Yes E) No;
Planters ❑Yes ❑No
Stucco; Brown -Finish
29.
Equip. Clearances; Panels-Motors-Mech. Equip.
77,
A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet
30.
Clothes Closet Light -Shower Light
78.
Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs.
79.
Water Well; Disconnect, Electrical, Plumbing
80.
Exterior Elec. Trim; G.F.I. Receptacle -Underground
Card B -I
Card B-1
Date Card -BI Date
Date Card -BI Date
81.
Ventilation throughout House
82.
Glass Protection
Date
MECHANICAL (Permit) OK except #'s
83.
Corrections from Previous Inspections
84.
85.
Gas Test -Meters Tagged; Gas -Electric
Water & Sewer Connected -C/O to Grade -HD Approval
_
31.
32.
A.C. Ducts: Insulation & Support
Vent Fan; Exhaust above Insulation
86,
Energy Compliance Certificate -Other Certificates
_
33.
Condensate Drain & Overflow; Size & Grade
34.
35.
Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet
Attic Access & Platform if Furnace in Attic
Card -BI
Card -BI
Date Card -BI Date
Date Card -BI Date
Card -BI Date Card -BI Date
Card -BI
Date
Date Card -BI Date
FRAMING(Plans) OK except #'s
Card -BI
Date Card -BI Date
Comments at Final:
36.
Sills; Proper Material & Anchors
_
37.
Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound
38.
Bearing Walls over Girders & Floor Nailing
39.
Draft Stop in Walls (rat proof)
40.
Fire Stops; Furred Ceilings -Stairs -Chases -Tub
_
41.
42.
43.
44.
Header & Beam -Size & Bearing
Hangers -Post Caps -Anchors -Connectors
Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfnq. _
Fireplace Ties or Type AFlue-Fireplace Throat
45.
Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
46.
eZrr. Windows or Exiting Doors -Sill Hgt. & Dimensions
47.
Garage Fire Protection Framing
(NOTE: Anentry must be made each time you visit jobsite)
V=OK,
O = Not OK 1
Not Applicable M O g I L'EROM ES
= Not Ready
MISCELLANEOUS '
Date
MOBIL
JiHOME UTILITIES ( ns) OK except q's
Date
DECKS, COVERS, CARPORTS, ETC. (Plans) OK except k's
o ing Requirements—Setbacks—Easements
1. Zoning Requirements—Setbacks—Easements
P—foils; Special MH Support—Sketch
2. Footings; Size—Depth—Spacing—Connectors
Sew ; Location—Test—Fall-C/O—Concrete
3. Decks; Girders and/or Joists—Decking—Bracing—Stairs—Rails
*io`Wa!g,w Location—Test—Easement Needed (Sketch)
4. Wood Awn.; Posts—Beams—Rftrs.—Connec.—Shthg.—Rig.—Bracing
lectricity; Location—Clearances—Grnd.—/ / Amp—Concrete
• Location—Test—Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG
5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures
6. Carports; Windows—Doors
Poo -Utility Clearance
OM
7. Elec.
41f91Bl
Date 1-92card-13I Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
MOBIL OME INSTALLATION (P OK except H's
Date
POOLS (Plans) OK except H's
Af,olloning Requirements—Setbacks—Easements
1. Setbacks—Easements
Footings; Size—Spacing—Marriage Line
2. Soils; Compaction—Structure Stability
A001 -Gas; MH Test—Demand—Valve—Connector
3. Pool Structure; Steel—Connections—Thickness—Dead Men—Lining
lectricity; MH Test—Crossovers—Breakers—Clearances
i
4, Elec.; Receptacles and Lighting; Distances—GFI
tin; MH Test—Fall—Flex Connector
5. Elec.; Pool Lighting; 15 volts—GFI
"ter; MH Test—Regulator—Connector
I
6. Elec.; Enclosures; Conduit Entries—Terminals—Listed
W r and Sewer Connected—C/O to Grade—HD Approval
7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater
05."Gas and Electricity Tagged
8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghig.
Boxes—Enclosures—Panel boards—Ins. to Main in Conduit
9--EMM—h7s�p.—Sketch
Cert. of Occupancy
9. Health Department Approval
? Card -BI
10. Plumb; Cir. Test—Water Supply Test
Date Card -BI Date
C d B -I Dat d -BI Date
Card B -I
Date Card -BI Date
�' Card -BI
Date Card -BI Date
0
1.
to
�'--; - COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS
196 -Memorial Way, Chico — Phone: 891=2751 ,
7 County Center Drive, OroviIle— Phone: 534-4541
Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57
CORRECTION NOTICE
BUILDING OR PROPERTY ADDRESS
A routine inspection Indicates that the following violations of County Ordinance
exist at the above address and should be corrected. Please notify this office
when correction of work is completed. If you have any question pertaining to this
matter, or need additional explanation, please contact this office immediately.
i
�7i11��
/ h
�y L
1
l 1
/ 7
Inspector Date "`t` �� - Date
i
COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS
196 Memorial Way, Chico — Phone: 891-2751 '
7 County Center Drive, Orovi Ile — Phone: 534-4541
Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57
CORRECTION NOTICE
d /BUILDING OR PROPERTY ADDRESS
A routine inspection indicates that the following violations of County Ordinance
exist at the above address and should be corrected. Please notify this office
when correction of work is completed. If you have any question pertaining to this
matter, or need additional explanation, please contact this office immediately.
,� ,Q6A".!-A' .9•/fA /t�dC/`�/ �/./i+►V /iV�/L8�7'Q.�Gi�'%�!//�/�/l�
i
Al, /v
;r
//y/ON1i
in V .
I
Inspector�'��
at.
COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE
OROVILLE, CALIF. - 534-4541
CERTIFICATE OF OCCUPANCY ,�
This mobilehome has been installed in accordance with the requirements
of the California Administrative Code, Title 25, Chapter 5, under permit
number 'r for the following location:
Owner
Owner's Address r
Mobilehome Mfg. ModelYear
Insignia No.Serial No.
It is hereby certified for occupancy at the above described location and
may be occupied.
Director of Public Works
Date By
THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED
White - Owner, Yellow - Installer, Pink - D.P.W.
.0
r COUNTY OF BUTTE - DEPARTI EN.T OF PUBLIC WORKS PERMIT NO.
7 -County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 �?S�
_ APPLICATION AND PERMIT
ASSESSO ARCEL N4JMBER
ZONING
BUILDING PERMIT
OWNER I TELEPHONEall/
OWNER' MA 1 ADDRESS yn
Z
S(7. FT. OCC. BUILDING VALUATION
CONTRACTOR'S NAM
Aok
TELEPHONE
CONTRACTO MAIL NG ADDRESS
Fireplace
CONSTRUCTION LENDE
UNKNOWN
Total Valuation $ '
Filing Fee
$ 10.00
LENDERS MAILING ADDRESS
Permit Fee
$
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
$
Penalty
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS
JI
Permit fee
$
BUILDING JDDRESS o
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Solar Water Heater
20.00
Water piping
5.00
LOT NO.SUBDI
VISION NAME
PARCEL MAP
Each qas water heater or vent
5.00
Gas piping system 1 - 5 outlets
5.00
USE OF STRUCTURE
SF [:]Duplex ❑ Mobi lehome Other
SPECIFY
Building sewer
5.00
Mobile Home S G W
Fr-_0:0:e:o
TYPE OF WORK
New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installations Other ❑
Describe work: —
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
, ain service 600V OR LESS
100 AMP OR LESS
10.00
Main service EA. ADD•L 100 AMP
2.50
NEW CONST. DWELLING OCCUP.&
OR ADDNS. ACC. BLDGS. .
2hQSgft
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (check One):
ElNON.R
I am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and m license is in full force and effect.
Y Classification
License No.
I I, as the owner, or. my employees, with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
f9r.-sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONSTR( ULTI.OUTLET
NO N.R ESID `BRANCH CIRCUITS2.50 ea
NEW CONSTR. ( POWER APPARATUS &)
ESI D. SINGLE OUTLET CIR.
zo®soe
Ex. Occup(o FIXTURES 6AL@30a
FIXED A POR
LNS R
Ex. Occup. OUTLETS (RESID )EA.) 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
Misc. Wiring 15.00
Permit Fee $
Contractor
MECHANICAL PERMIT
FiIingFee 10.00
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
DK I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Heating
Cooling
Hood
3.00
Ventilation
permit Fee
$
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of'the Countyot
Butte to enter upon the above-mentioned property for inspection purposes.
1 also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and expenses which may in any way accrue
aga'st said County in con equelLce of the granting of this permit.
�
X C A CIL �, Date �/�LD�/ "�CJ —�z�
Signature of Applicant – Owner Contractor EJ Agent ❑
An OSHA permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
TOTAL PERMIT FEE $
OCCUP. GROUP
TYPE OF CONST,
I
PARCEL
PD
I HD
I ISSUE
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRECT—OR OF PUBLIC
BY
P IT EXPIRES Date
the applicable provi-
resolutions to do
fees have been paid.
WORKS
Date i Z
/', '�
I
Receipt No.xw
WHITE-D.P.W.. YELLOW -ASSESSOR. ;INK -INSPE TOR, GOLDENROD -APPLICANT
r
82-34044
Return to DPW AGRICULTURAL STATEMENT OF -ACKNOWLEDGEMENT
JFFICif�L RECO1`� `
- 'FOR?"RESIDENTIAL DEVELOPMENT I yTEO�-
Fi E �:O FAD S ? �::;:moi: •:;',": i�: Fr.,
Section 26-8:1 of the Butte County Code requires this acknowledgement
be recorded prior to issuancesof a building permit.
qg
o� I� t? 3,. I .II
The property described herein is adjacent to land or included ELEAHUR M.6ECKERh1`"z
within an area zoned for agricultural purposes, and residents of CLERK -RECORDER ,
this property may be subject to inconveniences or discomfort arising E
from the use of agricultural chemicals, including, but not limited to herbicides,
pesticides, and fertilizers; and from the pursuit of agricultural operations including,
but not limited to cultivation, plowing, spraying, pruning, and harvesting which occa-
sionally generate dust, smoke, noise, and odor. Butte County has established agricul-
tural zones which have as a priority use for productive agricultural purposes, and'
residents within said zones and on adjacent property should be prepared to accept such
inconvenience or discomfort from normal, necessary farm operations.
All that real property situate in the County of Butte, State of California,
described as follows:
},
.,That certain Placer Mining premises being known as Mineral Entry -Mo. W. be#rag Lot
42 and embracing portions of Sections 28, 29, 32 and 33, 11ow whip 21 Nor -t., Ramie
4 East, M.D.S. t M . , specifically described its Patent to Spring Valley H icing and
Irrigation Company, dated August 15, 1282 and recorded SeptevbF-_ 4, 1882 in 1ao:%
C of Patents, at page 377, records of Butte County, California
EXCEPTING TKE.ZFRM any veins or lodes of quartz. or other rock in place bearing,
gold, silver, cinnabar, lead, tin, copper, or other valuable deposits within the
land above described which may have been discovered or known to exist on or prior
to June 9, 1877, r
e
ALSO EXCEPTING THEREFROM those certain areas containing 5.31 acres, mare or less,
and 2.43 acres, more or less, as described in said Patent recorded Septe=ber 4,
1882 in Book C of Patents at page 377, records of Butte County, California
Date:
State of+a�
SS.
County of -'Ry--{ C.. )
�nuee@@cif@eeeeuaeseL�eaeeee@e;ieeeeseeeanaeeeeet[e[[tn8
OFFICIAL SEAL' s
C , JOHN A. STANTON '
M„
NOTARY PURLIC -'CALIFORNIA
3 r COUNTY OF BUTTE
My ummission Eepiros January 20, 19"
aerYYei@0Y1ede9Yl@3"a@@F3�H61¢7lfL(:snae@B1YS9s&e9e®ASEetl .
PROPERTY OWNERS: rek
On this the 1,5_dk day of �®tJt�►-nlx(L 19 FZ ,
before me, the undersigned Notary Public, personally
appeared �Co
s r— o
0
0
a
G7:
known to me to be the.person(s) whose name(s)
subscribed to the within instrument and acknowledged
that .fin ic executed the'same for the purposes
therein contained.
IN WITNESS WHEREOF, I hereunto set my hand and official
seal.
Present A.P. NO. -1711— &1 6 -1
Notary Public
END Of DOCUMENT
sic t_ DIAPI,We.
V
c, 4-
Am,�
7 AAe4
m
ri
c, 4-
Am,�
7 AAe4
m
BUTTE COUNTY.DEPARTMENT OF PUBLIC WORKS"" "`
7 County Center Drive, Oroville, CA....
PHONE: 534-4541
MOBILEHOME INSTALLATION SHEET
1.
Owner's name:
2.
Installer's name: cS/iE�
3.
Is the sits currently under permit? Yet No
(If yes, furnish permit number OR.
Is the site an existing site? Yes / / No
(If yes, furnish two (2) plot plans.)
4.' 'Will
the mobilehome be located at least 5 ft. away from septic tank
and leach
fields and
clear of. all setbacks.and easements? Yes T;7jT No
(If no, clarify
)
(
)
5.
What is the mobilehome electrical rating? ------------------------
Amps
6.
What is the mobilehome site service rating? ;---------
Amps
7.,
What is the mobilehome site circuit breaker )rating? -------------
O
Amps
8.
Is there any other electric load to be'served by the mobilehome
siteservice? ---------------------------------------------------
Yes
No .
(I£ yes, identify the load and size: oa
(Amps)
3��
9.
What is the mobilehome site'gas pipe size? ----------------------
(in.)
10.
What is the type of gas service?j Natural
11.
What is the gas pipe length from meter or tank to the mobilehome?
4�
(ft.
12.
What is the mobilehome ga and. -----------------------------
BTU)
(This info ation not required if pipe length less than 6 ft. 'on
natural
gas
or less han,50 ft. on LPG.)
IMS P TEs " ,e6qu�,eED
MOBILEHOME SUPPORT DATA
X ` If -other than single wide,.
Mobilehome Mfr. 16PV//t// 7Z—: furnish Setup Model No. Year/Y7.f
Width 2-- (ft.) Box Length (ft.) Tagalong or Expando Size ft. x ft.
(SHOW SUPPORT DETAILS BELOW)
On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation
manual and structural setup sheets (if not on .file with the County of Butte).
All center supports measured from front of
mobilehome unless otherwise specified. ,
Footings (check one)
Single 9.1. Wood either
pressure treated or
foundation grade.
x 2. Other: (specify)
(f .)(in:) (in.) (in.) E]
Center s port Center suppo
locatio s* footing siz s Supporta (check one)
(in.) ( j 1: Concrete block.
x
❑ .2 : Other. ( specify)
(ft.)(in.)
!r—Tagalong or Expando,'
show support details.
(ft.)(in.)
in.) (in.)
LX --
Typical Support
_330-
(in.) (in.)
Footing Size
(ft.)( n.)
Max. Pier Spacing
n(i.'
(ft.)(in.)
Max. Overhang
(Ift.)l (in.)
(in.) (in.)
(ft.)(in.)
BUTTE COUNTY
BUILDING DEPARTMENT
*If
than drawn above,
APPR®VEp••- T
center piers are
other
/�
draw in -locations,,
spacing,, and dimensions.
COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO.
r 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541/� 7��/
APPLICATION A-ND�PERMIT in
/�J
ASSESSOR PARCEL NUMBER
41-- 33--30
ZO ING
_Z
BUIL61NG PERMI
OWNER I
S'• `/
0^l K Lr 1 E I~e X
TELEPHONE
S0. FT. OCC. BUILDING VALUATION
O N RMAI INO ADDRESS
a 3L `/7`/A
0� i
CONTRACTOR'S NAg
ITELEPHONE
C N A TOR'S MAI NG ADDRESS
ode -2 d� Z B ��„�
Fireplace
ONSTRUCTION LENDER
�"
UNKNOWN
Total Valuation $
Filing Fee
$ 10:00
LENDER'S MAILING ADDRESS
`-
Permit Fee
$
ARCHITECT OR ENGINEER -
d uCP
LICENSE NO.
Plan Checking Fee
$ /Otoo
Penalty
$ -
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Permit fee
$ 149,.00
BUILDING ADDRESS t
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Repair drainage or vent piping
5.00
Water piping
LOT NO.SUBDIVISION
NAME
PARCEL MAP
Each qas water heater or vent
5.00
Gas piping system 1 - 5 outlets
USE OF STRUCTURE
SF ❑ Duplex❑ MobilehomeEg Other
SPECIFY
Building sewer
a
Lawn sprinkler system
5.00
TYPE OF WORK
New ❑ Addition ❑ Remodel ❑ Utilities Installation ❑ Other ❑
Describe work:
Permit Fee
$ 40.0
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
Main service 100 AMS
P ORLESS
5.00
Main service EA. ADD•L 100 AMP
2.50
NEW CONST. DWELLING OCCUP.EI\
OR ADDNS. ACC. BLDGS. /
22 sq ft
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (Check one):
'
❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and my license is in full force and effect.
License No. Classification
I, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONSTR. -OUTLET 2,50 ea
NO BRANCH CIRC TS
NEW CONSTR POWER APPARATUS 6
NON.RESID. SINGLE OUTLET CIR.
EX. Occup(OUTLETS OR FIXTURES 50@25
IXED APP LHS, OR \
Ex. OCCup.(OUTLETS (RESID.) EA.! 2.00
Temporary service 10.00
Mobile Home Facilities
15.00
Misc. Wiring 7.50
Permit Fee $
Contractor
MECHANICAL PERMIT
Filing Fee 10.00
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a•Certificate
of Consent to Self -Insure.
I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Noticet Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith Comply with such
provisions or this permit shall be deemed revoked.
Heating
Cooling
Hood
3.00
Ventilation
El
Permit Fee
S
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the County of
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and expenses which may.in any way accrue
against said Cc n consequence f the granting of this permit.
X - Date �� 41
Signa a of Applicant — Owner ❑ Contractor ❑ Agent
OSHA permit is required for excavations over 5'0" deep and demolition or construct-
n Of structures over 3 uiredQf in height.eceipt
Mobile Home Installation Fee $
TOTAL PERMIT FEE $ Z.vo
OCCUP. GROUP
TYPE OF CONST,
PARCEL
PD
1717
I
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRECTO F PUBLIC
BY
PE -EXPIRES Date_
the applicable provi-
resolutions to do
fees have been paid.
WORKS
Date�1_?/
.�/�/
No. X60 /r
ITE-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR, GOLDENROD -APPLICANT
r
33 3.0
�► permit will be require( for the J ! . N u pan m 'eD c �•>� . o
i�stalla#ion of the mobi ehome. u�at
Nd�se
ility connections shall be vwltNlS
f 4 ft: of. the m6', _hornel 01ther
70' `'M'
directly behind or within the ree
half of the roadside (left) of -the
A setback of 5 ft, from thy' mobilehome.
property lines and s Sousa(
of 50ft..from the road
centerline shall be clear of
structures or equipment except
for a 2 ft. eave overhang.
. Ali
'als :& �orS{r, a�ship .5ht,ces (and
NQYE:--ASS Maters alis �d C rc! FI use in thy'
anCe with ��r .;-e reris:e.� des and
Co
Aeeora , escrif,FG� . 4qc, cS ,anica` 'i
of a quality nw plumUnq 13 !G ! /
Uniform Bi:ildiElectricallCode.
the National
BUTTE COUNTY
BUILDING DEPART"M�`�:�j -
'APPROVED
This set of plans and specifications MUST be
kept on the job at all rimes and it is unlawful to
make any changes or alterations on same without /
written permission from the Department of Public
XAIe_L" r^.n+v A Butte.
r
I
PERMIT NO. T366-81P,E
PERMIT EXPIRES
OWNER Spring Valley Minerals
CONTR. Gary Ledger, Oroville
ASSESSOR PARCEL 41-33-30
LOCATION 4 mi.S.of Cherokee Rd., 2 mi.E.
of Hwy 70
, E, a& _7/0
Temp. Power Pole
Called PG&E
Temp. Elec. Service
Called PG&E
Temp. Gas Service
Called PG&E
JOB FINALED (Date)
Signature /
J=OK
0 = Not OK
= Not Applicable MOBILEHOMES
= Not Ready
�1
MISCELLANEOUS
Date
MOB16EHOME UTILITIES (Plans) OK except ti's
Date
DECKS, COVERS, CARPORTS, ETC. (Plans) OK except N's
Z ing Requirements—Setbacks—Easements
1. Zoning Requirements—Setbacks—Easements
So' ; Special MH Support—Sketch
2. Footings; Size—Depth—Spacing—Connectors
. Ser; Location—Test—Fall-C/0—Concrete
j
3. Decks; Girders and/or Joists—Decking—Bracing—Stairs—Rails
ocr; Location—Test—Easement Needed (Sketch)
j
4. Wood Awn.; Posts—Beams—Rftrs.—Connec.—Shthg.—Rfg.—Bracing
lectricity; Location—Clearances—Grnd.—/ Amp—Concrete
5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures
6. Gas; Location-Test—Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG
I
6. Carports; Windows—Doors
7 ity Clearance
7. Elec.
r
Card -BI
Date. Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date
Date Card -BI Date
MOBILEHOME INSTALLATION (Plans) OK except N's
1. Zoning Requirements—Setbacks—Easements
Card -BI
Date
Date Card -BI Date
POOLS (Plans) OK except N's
1. Setbacks—Easements
2. Footings; Size—Spacing—Marriage Line
2. Soils; Compaction—Structure Stability
3. Gas; MH Test—Demand—Valve—Connector
3. Pool Structure; Steel—Connections—Thickness—Dead Men—lining
4. Electricity; MH Test—Crossovers—Breakers—Clearances`
4, Elec.; Receptacles and Lighting; Distances—GFI
5. Drain; MH Test—Fall—Flex Connector
;
5. Elec.; Pool Lighting; 15 volts—GFI
6. Water; MH Test—Regulator—Connector
6. Elec.; Enclosures; Conduit Entries—Terminals—Listed
7. Water and Sewer Connected—C/O to Grade—HD Approval
7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater
8. Gas and Electricity Tagged
8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghtg.
Boxes—Enc losures— Pane lboards—Ins. to Main in Conduit
9. Exits; Insp.—Sketch
10. Cert. of Occupancy
9. Health Department Approval
10. Plumb; Cir. Test—Water Supply Test
Card B -I
Date Card -BI Date
"Card -BI
Date Card -BI Date
Card B-1
Date Card -BI Date
;Card -BI
Date Card -BI Date
V = OK
O = Not OK ?
- = Not Applicable
* = Not Ready RESIDENTIAL (Single and Duplex
Date
UNDERFLOOR Plans OK except #'s
Date
FRAMING (Continued)
1.
Zoning requirements -Setbacks -Easements
48.
Property Line Firewall & Openings
2.
Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth
49.
Ext. Doors -One 3' -Check Garage -3rd story, 2 exits
3.
Ftg., Garage; Soils -Steel- / /" Ftg. Depth
50.
Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
4.
Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth
51.
Plywood on Roof Overhang -Attic Vents -Rafter Outriggers
5.
Stemwalls, Main; Steel-Blockouts-Wrapped-Slab
52.
Siding -Nailing -Veneer
6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab
53.
Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access
7.
Piers -Fireplace Ft .-Steel
54.
Glazing Area -Glass Protection -Skylights -Plastic
8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test
55.
Shear Walls; Nailing -Bolts
9. Gas Pipe; Size -Anchors
10.
Water Pipe; Test -Anchors -Regulator -Service Test
11.
Electric; Underground
12.
Plenums & Ducts; Clearance -Material -Support -Ins.
13.
Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
Card -BI
Date Card -BI Date
Card -BI
Card -BI
Date Card -BI Date
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FINAL (Plans) OK except q's
Card -BI Date Card -BI Date
Date
PLUMBING (Permit) OK except N's
14. Water Ht.; Vent -Access -Combustion Air
56.
Ext. Steps -Door & Sidelight Protection -Landings
57.
Smoke Detector
58.
Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor-Ducts-Mech. Protection
15. Water Pipe; Test & Anchors -Nail Protection
16.
D.W.V.; Test-Fttngs & Anchors -Nail Protection
59.
Bedroom Exiting
17.
Shower Pan; Test, First Floor -Tub Access
60.
G.F.I. & Bath Fixtures & Tub Access
18.
Test Tub & Shower, 2nd Floor -Tub Access
61.
Elec. Trim & Subpanel; Breaker Sizes -Labels
19.
Gas Pipe; Size & Anchors
62.
Stairs & Rails
63.
Fireplace or Stove; Clearances -Hearth
Card -BI
Date Card -BI Date
64.
Elec. Outlets at Wood Panel; Int. & Ext.
65.
Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance
Card -BI
Date Card -BI Date
66.
Elec. Outlets & Receptacles at Kit. Counter
Date
ELECTRICAL(Permit) OK except q's
67.
Garage Fire Door; Swing -Landing -Closer
68.
A.C. Duct in Garage -Damper
20.
Fixture & Transformer Clearance -Ins. Protection
69.
Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.-
In Garage; Above Floor-Mech. Protection
21.
Elec. Receptacles Spacing -Lights &Switches at Doors
70.
Plb., Elec. & Mech. Equip. Listed for Location
22.
Size Boxes & No. of Conductors -Stapled
71.
Elec. Receptacles in Garage; (G.F.I.)-Romex Protec.
23. Romex Installed Close to Edge of Studs & C.J.
24.
Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water
72.
Insulation -Foam -Looked in Attic ❑Yes
73.
Guard Rails &Deck Construction -Post Caps
_
25.
26.
2 Appliance Circuits in Kitchen & Conductor Size
Subieed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or AI
74.
Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance
Looked under Floor ❑ Yes
27.
Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al,
Insulated Neutral ❑Yes ❑No
75,
Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No;
Planters Oyes ❑No
28.
Service -Riser Conductors & Ground -Main Disconnect
76.
Stucco; Brown -Finish
29.
Equip. Clearances; Panels-Motors-Mech. Equip.
77,
A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet
30.
Clothes Closet Light -Shower Light
78.
Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs.
79.
Water Well; Disconnect, Electrical, Plumbing
80.
Exterior Elec. Trim; G.F.I. Receptacle -Underground
Card B -I
Date Card -BI Date
81.
Ventilation throughout House
Card B -I
Date Card -BI Date
82.
Glass Protection
Date
MECHANICAL (Permit) OK except q's
83.
Corrections from Previous Inspections
84.
Gas Test -Meters Tagged; Gas -Electric
31.
A.C. Ducts; Insulation & Support
85.
Water & Sewer Connected -C/O to Grade -HD Approval
_
32.
33.
Vent Fan; Exhaust above Insulation
Condensate Drain & Overflow; Size & Grade
86.
Energy Compliance Certificate -Other Certificates
34.
Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet
35.
Attic Access & Platform if Furnace in Attic
-
Card -BI
Date Card -BI Date
Card -BI
_
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FRAMING(Plans) OK except q's
Comments at Final:
36.
Sills; Proper Material & Anchors
37.
_
Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound
_
38.
Bearing Walls over Girders & Floor Nailing
39.
Draft Stop in Walls (rat proof)
_40.
Fire Stops; Furred Ceilings -Stairs -Chases -Tub
Header & Beam -Size & Bearing
_41.
42.
43.
44.
Hangers -Post Caps -Anchors -Connectors
Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng.
Fireplace Ties or Type A Flue -Fireplace Throat
_
45.
Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
_
46.
Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
47.
Garage Fire Protection Framing
(NOTE: Anentry must be made each time you visit job site)
COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS
695 Oleander Avenue, Chico - Phone 343-4211, Ext. 70
7 County Center Drive, Oroville — Phone 534-4541
Skyway and Elliott Road, Paradise — Phone 877-3435
CORRECTION NOTICE
BUILDING OR PROPERTY ADDRESS
A routine inspection Indicates that the following violations of County Ordinance
exist at the above address and should be corrected. Please notify this office
when correction of work is co leted. If you have any question pertaining to this
matter, ^ n,ped additional eNanation, please contact this offAe immediately.
Inspector Date
J - COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO
7 County Center Drive - Oroville, Califa)rnia 9!4965 - Telephone 916/534-451
APPLICATION AND PERMIT
ASSESSOR PARCEL NUMBER
41-33-:3o
ZONING
X Z
66ILDING PERMI
OWNER .
k ydat
TELEPHONE
SO. FT. OCC. BUILDING VALUATION
7E'S MAILRG DRESS
It OcA 3714--W
CONTRACTOR• AM -
v -e
TELEPHONE
'
C T A TO 'S MAILING ADDRESS
do � w_cl
Fireplace
ONSTRUCTION LENDER
au
UNKNOWN
Total Valuation Is
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
`—
Permit Fee
$
ARCHITECT OR ENGINEER
66
LICENSE NO.
Plan Checking Fee
$ 0,00
Penalty
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Permit fee
$ 410.00
BUILDING ADDRESS 4. `/ Q .50t/ O
PLUMBING PERMIT
Filing Fee 10.00
2 Q1 �'- C • �^ °
Each Trap
2.00
Repair drainage or vent piping
5.00
Water piping
/64,00
LOT NO.
SUBDIVISION NAME
PARCEL MAP
Each qas water heater or vent _
5.00
Gas piping system 1 - 5 outlets
0. 00
USE OF STRUCTURE
SF ❑ Duplex❑ Mobilehome® Other
SPECIFY
Building sewer
/0-00
Lawn sprinkler system5.00
'
TYPE OF WORK
New ❑ Addition ❑ Remodel ❑ Uti lities X_ Installation ❑ Other ❑
Describe work:
Permit Fee
$40,C)0
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
Main service 100 AMP 00V OR ORSLESS
5.00
Main service EA. ADD'L 100 AMP
2.50
NEW CONST. I DWELLING OCCUP.N
OR ADDNS. \ ACC. BLDGS.
22 sq ft
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (check one):
❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business.
and Professions Code and my license is in full force and effect.
License No. Classification
I, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
I am exempt under Sec. , Business and Professions Code
for this reason
NEW CON STR. 171-OUTLET 2,50 ea
NON-RESID BRANCH CIRC ITS
NEW CONSTR. (POWER APPARATUS &I
NON-RESID. SINGLE OUTLET CIR, I
5002SC
Ex. Occup OUTLETS OR FIXTURES ggL�ol
Ex. Occup.(o LITLETS FIXED P(RESID )REA.,- 2.00
Temporary service 10.00
Mobile Home Facilities 15.00 lS�GO
Misc. Wiring 7.50
Permit Fee $ 2!�;&p0
Contractor
MECHANICAL PERMIT
FiIingFee 10.00
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
mit I shall not employ any person in any manner so as to become subject
Y" to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Heating
Cooling
Hood
3.00
Ventilation
permit Fee
S
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the County of
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and enses which may in any way accrue
agaisaid County/)n conseq nc a granting this permit. p
Xorate x—.20 0 l
Signaturef ppllcant — er Contractor ElAgent
An OSHA permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
TOTAL PERMIT FEE $ AO
OCCUP. GROUP
I TYPE OF.CONST.
PARCEL
PD ND
990E
t/
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRECT OF PUBLIC
B
PitT EXPIRE Date-
the applicable provi-
resolutions to do
fees have been paid.
WORKS
Date ill"P
r,/i'—g
Receipt No. �d
WHIT!-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT
E93-880ttached)
PERMIT NO. —
PERMIT EXPIRES' I
OWNER S12RIMC VAT.T.FY MTNFRAT 4(F Dpme S)
CONTR. siamPr
ASSESSOR PARCEL 43-33-30
LOCATIONCharelree Rd,—OR—d 11 A
&/T
A:
r
Lf _ 1 y -D7
Temp. Power Pole
} Called PG&E
Temp,, Elec. Service
Called PG&E
Temp. Gas Service /
Called PG&E r
{ JOB FINALED (Date)
1
Signature—
= OK
0 = Not. OK, ..
Not Readyable
= MOBILE HOMES
r
MISCELLANEOUS =-
Date
MOBILE HOME UTILITIES (Plans) OK except #'s
Date
DECKS,COVERS,CARPORTS,GARAGES, (Plans)OK except #'s
1. Zoning Requirements -Setbacks -Easements
1. Zoning Requirements -Setbacks -Easements
.2. Soils; Special MH Support -Sketch
2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel
3. Sewer; Location -Test -Fall -C/O -Concrete
y
3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails
. 4. Water; Location -Test -Easement Needed (Sketch)
4. Wood Awn.; Posts:Beams-Rftrs.-Connec.-
Shthg.-Rfg.-Bracing
5. Electricity; Location-Clearances-Grnd.-/ • / Amp -Concrete
6. Gas; Location -Test -Wrap: /- /"L"ft.
/ /"Nat. or/ /"L"ft./ /"LPG
5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures.
6. Carports; Windows -Doors
7. Utility Clearance
7. Elec.
8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses
9. Siding; Nailing -Veneer -Stucco -Mesh
Card -B1
Date Card -B1 Date
10. Roof; Shthg-Roofing
Card -B1
Date Card -B1 Date
,
11. Ext.; Steps -Doors -Landings
Date
MOBJLEMOME INSTALLATION Plans OK except #'s
o ng Requirements -Setbacks -Easements
Card -B1
Date Card -B1 Date
r' ootings; Size:Spacing-Marriage Line
r Card -Bt
Date Card -131 Date
H Test -Demand -Valve -Connector
lect ' ity; MH Test -Crossovers -Breakers -Clearances
; Date
POOLS (Plans) OK except #'s
ain; MH Test -Fall -Flex Connecto
1. Setbacks -Easements
§'W ater MH Test-Regulato actor
2. Soils; Compaction -Structure Stability
er and Sewer Connected -C/O to Grade -HD Approval
3. Pool Structure; Steel -Connections -Thickness -
Dead Men -Lining
8 nd Electricity Tagged
xrt fisp.-Sketch
r
4. Elec.; Receptacles and Lighting, Distances-GFI
ID -Cert. of Occupancy
5. Elec.; Pool Lighting; 15 volts-GFI
'
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
'
7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater
8. Elec.;Grounding; Equip. w/5' -circulating Equip. -Pool Lghtg.
Boxes-Enclosures-Panelboards-Ins. to Main in Conduit
Card -B1 Date Card -61 D -
Card -B
Date - Card-Bll Date
(
9. Health Department Approval
10. Plumb.; Cir. Test -Water Supply Test
r
( Card -B1
Date Card -B1 Date
Card -B1
Date Card -131 Date
I
{
r
t.
= OK
0 = Not Ap �lp
- = Not pljcakile
RESIDENTIAL (Single and Duplex)
= Not Ready
Date UNDERFLOOR (Plans) OK except #'s
1. Zoning requirements -Setbacks -Easements
2. Ftg., Main; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth
3. Ftg., Garage; Soils -Steel-/ /" Ftg. Depth
4. Ftg., Porches & Decks; Soils -Steel-/ /"Ftg. Depth
5. Stemwalls, Main; Steel-Blockouts-Wrapped
6. Stemwalls, Garage; Steel-Blockouts-Wrapped
7. Slab; Steel -Wrapped
8. Piers -Fireplace Ftg.-Steel
9. D.W.V.; Fall -Fittings -Test -2 way C/O -Sewer Test
10. Gas Pipe; Size -Anchors
11. Water Pipe; Test -Anchors -Regulator -Service Test
12. Electric; Underground
13. Plenums & Ducts; Clearance-Material-Supprt-Ins.
14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
15. Insulation
Card -B1 Date Card -B1 Date
Card -81 Date Card -131 Date
Date PLUMBING (Permit) OK except #'s
16. Water Ht. Vent -Access -Combustion Air
17. Water Pipe; Test & Anchors -Nail Protection
18. D.W.V.; Test-Fttngs & Anchors -Nail Protection
19. Shower Pan; Test, First Floor -Tub Access
20. Test Tub & Shower, 2nd Floor -Tub Access
21. Gas Pipe; Size & Anchors
Card -B1 Date Card -131 Date
Card -B1 Date Card -B1 Date
Date ELECTRICAL (Permit) OK except #'s
22. Fixture & Transformer Clearance -Ins. Protection
23. Elec. Receptacles Spacing -Lights & Switches at Doors
24. Size Boxes & No. of Conductors -Stapled
25. Romex Installed Close to Edge of Studs & C.J.
26. Equip. Ground made up w/Meeh. Fasteners -Bond Gas & Water
27. 2 Appliance Circuits in Kitchen & Conductor Size
28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / /ga.
Cu or Al
29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al.
Insulated Neutral Yes No
30. Service -Riser Conductors & Ground -Main Disconnect
31. Equip. Clearances Panels-Motors-Mech. Equip. I
32. Clothes Closet Light -Shower Light -Spa Light
Card -81 Date Card -61 Date
Card -131 Date Card -131 Date
Date MECHANICAL (Permit) OK except #'s
33. A.C. Ducts Insulation & Support
34. Vent Fan; Exhaust above insulation
35. Condensate Drain & Overflow; Size & Grade
36. Furnace -Vent; Access -Comb. Air -Return Air Vent -115 outlet
37. Attic Access & Platform if Furnace in Attic
Card -B1 Date Card -131 Date
Card -B1 Date Card -131 Date
Date FRAMING (Plans) OK except #'s
38. Sills, Proper Material & Anchors
39. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound
40. Bearing Walls over Girders & Floor Nailing
41. Draft Stop in Walls (rat proof)
42. Fire Stops; Furred Ceilings -Stairs -Chases -Tub
43. Header & Beam -Size & Bearing
Date FRAMING (Continued)
44. Hangers -Post Caps -Anchors -Connectors
45. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng.
46. Fireplace Ties or Type A Flue -Fireplace Throat
47. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
48. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
49. Garage Fire Protection Framing
50. Property Line Firewall & Openings
51. Ext. Doors -One T -Check Garage -3rd story, 2 exits
52. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
53. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers
54. Siding -Nailing Veneer
55. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access
56. Glazing Area -Glass Protection -Skylights -Plastic
57. Shear Walls; Nailing -Bolts
58. Insulation-Walls-Clg.
59. Infiltration-Walls-Wndws
Card -B1 Date Card -Bt Date
Card -B1 Date Card -131 Date
Date FINAL (Plans) OK except #'s
60. Ext. Steps -Door & Sidelight Protection -Landings
61. Smoke Detector
62. Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor -Ducts -Meth. Protection
63. Bedroom Exiting
64. G.F.I. & Bath Fixtures & Tub Access -Spa
65. Elec. Trim & Subpanel; Breaker Sizes -Labels
66. Stairs & Rails
67. Fireplace or Stove; Clearances -Hearth
68. Elec. Outlets at Wood Panel; Int. & Ext.
69. Kit. Fixt. & Appliance; Grnd. -Air Gap -Cooking Clearance
70. Elec. Outlets & Receptacles at Kit. Counter
71. Garage Fire Door; Swing -Landing -Closer
72. A.C. Duct in Garage -Damper
73. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.-
In Garage; Above Floor -Meeh. Protection
74. Plb., Elec. & Mech. Equip. Listed for Location
75. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec.
76. Insulation -Foam -Looked in Attic o Yes
77. Guard Rails & Deck Construction -Post Caps
78. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth
Clearance Looked under Floor O Yes
79. Following instld.; Drive O Yes 0 No; Walks 0 Yes O No;
Planters 0 Yes 0 No
80. Stucco; Brown -Finish
81. A.C. Unit; Disconnect, Electrical, Plumbing
82. Vents Above Roof; PIbg.-Appliance-Firep I. -Clearance to
Openings.
83. Water Well; Disconnect, Electrical, Plumbing
84. Exterior Elec. Trim; G.F.I. Receptacle -Underground
85. Ventilation throughout House
86. Glass Protection
87. Corrections from Previous Inpections
88. Gas Test -Meters Tagged; Gas -Electric
89. Water & Sewer Connected -C/O to Grade -HD Approval
90. Energy Compliance Certificate -Other Certificates
Card -81 Date Card -B1 Date
Card -131 Date Card -B1 Date
Card -131 Date Card -B1 Date
Comments at Final:
(NOTE: An entry must be made each time you visit job site)
MOBILEHOME INSTALLATION ACCEPTANCE
COUNTY OF BUTTE
D&ARTMENT OF PUBLIC WORKS — 7 COUNTY CENTER DRIVE
OROVILLE, CALIFORNIA — 534-4541
PERMIT N0,
Address or location of mobilehome '
Owner's name
Owner's address
Insignia or hud number
Manufacturer's name
Serial number of V.I.N.
Year of manufacture
tial Approving Installation) (Date)
IF THE MOBILEHOME IS MOVED OR RELOCATED, THE MOBILEHOME INSTALLATION
ACCEPTANCE SHALL BECOME INVALID. THIS FORM SHALL NOT BE USED WHEN THE
MOBILEHOME IS INSTALLED ON A FOUNDATION SYSTEM.
513B White - Owner, Yellow - Installer, Pink - D.P.W.
IL
COUNTY OF BUTTE
DEPARTMENT OF PUBLIC WORKS
196 Memorial Way, Chico — Phone: 891-2751 t
7 County Center Drive, OroviIIe — Phone. 538-7541
747 Elliott Road, Paradise— Phone: 872-6307
CORRECTION NOTICE
OWNER- " , PERMIT NO.
A routine inspection indicates that the following violations of County Ordinance
exist at the above address and should be corrected. Please notify this office
when correction of work is completed. If you have any question pertaining to this "x
matter, or need additional explanation, please contact this office immediately.
A
-5
'Ya
. =Y
z
f•
/ '
Inspector Date--,-, �-
Pr'""`�'"""�'"°
COUNTY OF BUTTE
,.� DEPARTMENT OF PUBLIC WORKS
196 Memorial Way, Chico — Phone: 891-2751 -
7 County Center Drive, Orovi Ile — Phone: 538-7541
747 Elliott Road, Paradise — Phone: 872-6307 ,+
CORRECTION NOTICE
A routine inspection indicates that the following violations of County Ordinance
exist at the above address and should be corrected. Please notify this office
when correction of work is completed. If you have any question pertaining to this
matter, or need additional explanation, please contact this office immediately.
�.3
..til
1
"J
.
AlA
.rJ
Inspector// Date — D
COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKSPERMIT NO. /)
+ 7 County Center Drive - Oroville. California x,5965 - Telephone: 916/538-754102-1
1 _5 _.V Y
APPLICATION AND PERMIT 0 CJ
N
ASSESSOR PARCEL BE
✓.0
OO ING
♦
r BUILDING PERMIT '
OWNER
7�
TEL PHONE
S0. FT. OCC. BUILDING VALUATION
OWNER'S MAI IN ADDRESS (N Y
CONTRACTOR'S N6AME
TELEPHONE
CONTRACTOR'S MAILING ADDRESS -
Fireplace
CONSTRUCTION LENDER
UNKNOWN-
Total Valuation Is
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
Permit Fee
$
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
.$
Energy Plan Checking Fee
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Penalty
$
BUILDING ADDRESS
aG r
Permit fee
$
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Solar or heat pump water heater
20.00
LOT NO.
SUBDIVISION NAME
PARCEL MAP
Water piping
5.00
Each qas water heater or vent
5.00
USE OF STRUCTURE
SF ❑ Duplex❑ MobilehomeU3"'-Other
SPECIFY
Gas piping system 1 - 5 outlets
5.00
Building sewer
5.00
Mobile Home S G W
0.00 ea
]_
TYPE OF WORK I
New ❑ Addition ❑ Remodel ❑ Utilities ❑ Instal latton9�--Other ❑
Describe work:�Q�(
I I
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
V R
Main service 100 AMP ORSLESS
10.00
Main service EA. ADD'L 100 AMP
2.50
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (check one):
F -1I am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and my license is in full force and effect.
License No. Classification
IJ71• '1, as the owner, or my employees with wages as their sole compen-
FFYY��YY'' sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONST. DWELLING OCCUP.m`
OR ADDNS. ACC. BLDGS. /21/2
2sgft
NEW CONSTR. TI -OUTLET
NON.RESIO .BRA C CIRC ITS
2,50 ea
/POWER APPARATUS e
(SINGLE OUTLET CIR.
Ex. Occup OUTLETS OR FIXTURES
eiAL@AL02230
FIXED APPLNS. OR
Ex. Occup, OUTLETS (RESIO.) EAJ
2.00
Temporary service
10.00
Mobile Home Facilities
15.00
Misc. Wiring
15.00
Permit Fee
$
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
1 shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement,should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Contractor
MECHANICAL PERMIT
Filing Fee 10.00
Heating
Cooling
g
Hood
3.00
Ventilation
Permit Fee
=
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the County of
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, i keep harmless the County of Butte against
all liabil' ' ju ts, co ,Andts, expenses which may in any way accrue
agof this permit.
�1_�
X Date o�
Sig tyre of Applicant — Owner ontrac or ElAgent®
An SHA permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
Energy Inspection Fee $
TOTAL PERMIT FEE
OCCUP.
CONST.TYPEJ
JSCHOOLJPL7_ARCELJ
PD
14;1.17
This p it is hereby issued under
sion of the Butte County Code and/or
WOr in ab ve for which
E TOR OF PUBLIC
B Y
PERMIT EXPIRES Date
the, applicable prov.1-
resolutions to do
fees have been paid.
WORKS
Date
Receipt No.
WHIT[-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT
AA
.lt
COUNTY OF BUTTE - DEPAR46NT OF PUBLIC WORKS - BUILDING DPVIS,ION -
F Aa:
L�IFORf'JA 95965 - TELEPHONE: 916/538-754
11 COUNTY CENTER DRIVE - OROVILLE,�1
PERMIT APPLICATION DATA SHEET
Permit No.
OWNER �/�'' A. P. No. `1'� 3C�
Proposed Building Use X11;1 Building Inspector g//�.' Dater���
At time of permit application, I was advised the following data must be submitted prior to permit processing
and/or issuance: DATE RECEIVED APPROVED
�1. All items have be�_e.n- ubmitted.
2. Plot plans i upd lica ' /triplicate, signed by preparer of plans.
3. Complete plans In duplicate/triplicate, signed by preparer of plans.
4. Complete engineered plans and calcs, with wet signature on plans.
5. Plans with Energy Design Compliance Statement. . . . . .
6. School District "Fees Paid" Stamp on Floor Plan.
7
8.
9.
�10.
12.
13.
�5.
6.
17.
18.
19.
20.
21.
22.
Statement of Intent for Non -Heated and AC Buildings.
Fees of $ . . . . . . . .
Letter of signature authorization. . . . . . .
Sanitation approval from_ Health Dept.
Planning approval for (A) Use: (B) Parking:
Certificate of Workmen's Compensation Insurance. . . . . .
Contractor's License Information (no., name style, classif.)
Owner -Builder Verification (Given to owner,], Mail to owner) _
Improvements may be required. . . . . . . . . . . .
Mobilehome Installation Data. . . . . . . . . .
Pre•Inspec. request to (Date)
Pre -Inspection for _.. _ _..._.__ _ Required. Building Inspector
Recorded copy of Agricultural Acknowledgment Statement.
Driveway Permit,
Plot plan approval from city of _
Engineered trusses in duplicate (required prior to plan check) _
When you issue thepermit, proc ss as follows: � Mail to owner. Mail to contractor_
Telephone -5 51-P -Ad and old for pickup _Ay -,7 offiV e, Deliver w/inspector.
Other
90 _
Applicant PDate
Copy of plans sent Health Dept., Fire Dept., Other Date
The following data must be submitted prior to
1. Index permit for above items No.
2. Additional items required: _
rTjt issuance: (Circle new item not checked above).
Contractor, designer, owner, was advised of above required data by_phone_L%fLrnail_counter by date
Contractor, designer, owner, was advised c? above required data by—phone —ma il—counter by date
/a y/
Plans checked by � Date Plans approved by Date
,
Sets of plans on hold in File cabinet AP folder
Copy—DP,W
TO Building Department
FROM: Environmental Health
SUBJECT:. Sanitation Clearance
Owner Location AP#
Plan Approved for: Sewage Disposal _ Water Supply
Hold final for: Water Supply.
Final clearance O.R..for: Water Supply
Clearance for _ �- bedroom mobile home. Other
NOTE ***
Sanitarian Date
0
COUNTY OF BUTTE - Department of Public Works
7 County Center Drive, Oroville, CA 95965 Phone: 916-538-7541
OWNER -BUILDER VERIFICATION
Attention Property Owner:
An 'owner -builder" building permit has-been applied for in your name and bearing
your signature.
Please complete and return this information at your earliest opportunity to avoid
unnecessary delay in processing and issuing your building permit. No building permit
will be issued until this verification is received.
1. I personally plan to provide the major labor and materials for construction of
the proposed property improvement (yes or no) y.a 5
2. I (have/ha%enegot) signed an application for a building permit
for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed
construction:
Name
Address City
Phone Contractors License No.
4. I plan to provide portions of this work, but I have hired the following person
to coordinate, supervise, and provide the major work:
Name
Address City
Phone Contractors.License No.
5. I.will provide some of the work but I have contracted (hired) the following
persons.to provide the work indicated:
Name Address Phone Type of Work
Signed:
Property.Owner
Social Security Number
v
NOTE: This Owner -Builder Verification is sent to you as required by.Sections 19831 and
19832 of the California Health and Safety Code.
This verification must be completed and returned to -our office before we are per-
mitted to issue the permit.
e� ��
�_/"��0 i
(N ��P
'—T�7 . (/ �1C� ._ �/ VI � /'I�Cllit.Cr�S. n�^'l.
0
5 `
`♦ '�. \_jam
aA-
Permit will to require < or the
installation of the mob, ehOme
I
c ee -33 30
IW A ',-0
J4.;e A FS/I v 0a
"
ems
14 d v !S. CC
Q
-200
A setback of 5 ft. from the"
property lines and a sctbac4
of 50ft. from the road
centerline shall be clear of
structures or equipment except
for a 2 ft. eave overhang.
Orla
0 and
ccc.r�'Cln'
'e V4 I C o c s
of 0
t
the U n1i ojion,l Icckr
This set of plans and specifications MUST 6e
l:epf on the job of c.Al times cnd if is unlawful to
n'IrAo vny*chanqes or 'ojfnrr.-+7rns on some withoutwriffen permission ,frcm 6e Department of PU61"c
c I ms shall be Mthftl
lity c
71 li, Ttconne
4 ft. of the m =home, f."I'ller
directly behind or within the re0t`
half Of .1he
rnobileborne._____----------*
7// F
rr
BUTTE COUNTY
BUILDING DEPARTMENT
APPROVED
-T
BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS
7 County Center Drive, Oroville, CA
PHONE: 538-7541
MOBILEHOME INSTALLATION SHEET
1. Owner's Name: F% NVA /IN k" /M E:R S
2. Installer's Name:
3. Is the site currently under permit? Yes No I I
(If yes, furnish permit number ) OR
Is the site an existing site? Yes El� No EJ
(If yes, furnish two plot plans.)
4. Will the mobilehome be located at least 5 ft. away from septic tank and leach
fields and clear of all setbacks and easements? Yes No
(If no, clarify
5. What is the mobilehome electrical rating? --------------- 0 4EW Amps
6. What is the mobilehome site service rating? ------------- �SQ Amps
7. What is the mobilehome site circuit breaker rating? ----- TO Amps
8. Is there any other electric load to be served by the
mobilehome site service? --------------------------------
Yes F] No
(If yes, identify the load and size: (Load) .(Amps)
9. What is the mobilehome site gas pipe size? ----= --------- ��-- (in.)
10. What is the type of gas service? ------------------- Natural F-1. LPG
11. What is the gas pipe length from meter or tank to the
------------ ------------------- E
mobilehome?----------- -- ft.).
4
12: What i8•theµmobilehome gas demand? ---------------------- (BTU)
*(This information not required if pipe length less than 6 ft. on
natural gas or fess than 50 ft. on LPG;)
a ..
MOBILEHOME SUPPORT DATA
yIf other than single wide,
Mobilehome Mfr. S i4VW4 Afs lye iwc. furnish Setup Model NO.
r. w
Year 19 � 1
Widtht�'(ft.) Box Length (ft.) Tagalong or Expando Size ft. x ft.
ip 15-/
On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation
manual and structural setup sheets (if not on file with the County of Butte).
FOOTINGS (check one) P1. Wood -pressure treated or foundation grade. 2. Other (specify)
SUPPORTS (check one) RV_
Concrete block.a 2. Other (specify)
Pier Footing Sizes and Locations
SINGLE -WIDE MULTI -WIDE
Lines _ Line
Line 2 _ _ _ `' _ _ _ _ _ _ _ � Line
Main Beams
Linc 2 _ , — _ _ — — — — — _ — — — — Line
— — — — — Main Beams — — — —
� ine 2
Line 1 Piers:
Size -Min. ------------
S pac I ng -Max.
-----------Spacing-Max.---
Fran finds -Max. -------
Line 1 Piers:
Size-Mln. ------------
Spat Lig-Max----------
From
--,------From Ends -Max.------- U '
Line 3 k of loads:
Size -Min -------------
Line 4
Tag or Triple
In, 4
r Line 1
Line 1 Openings:
Size -Min. ------------------
nx u
Each Side of Openings
With Width Over ---------
Line ] Piers: (Under Bearing Wall Only)
Size -Min .------------------
x
`Spacing -Max. ---------------
From Ends-Max--------------
11X "x 1. Ix 1. "x 11 "x 1. "x "x "x
Location (From Front) _ _ _ 11 1 _ _ _ 1. '_ _
1.1.ne. 4 Piera: Line 5 Piers: (Under Bearing Walls Only)
Siz,!-Min.------------ Size -Min -------------------
'k "x
Spaciog-Max.--I------- Spacing -Max .---------------
From Ends -Max.------- �_ �� From Ends -Max .-------------
Line_ 5 Roof loads:
S1zc-MJu.---'---------�
.x "x "x "x "x "x "x x
l,ocaLion (From Front)
~ PERMIT NO. 692-86P(MH)
PERMIT EXPIRES I12f,1R7
OWNER SPRTNG VAT.T.EY MTNF.RAT.S
CONTR. Cal Gas
ASSESSOR PARCEL 41-33-30
_-- ' mi S Cherokee Rd. 2 mi E Hwv 70.0rc
�6 AV G �
f
x
Temp. Power Pole
Called PG&E
{` Temp. Elec. Service
Called PG&E
(, Temp. Gas Service "
Called PC
JOB FINALE[
i,
Signature
J = OK
O = Not OK
= Not Applicable MOBILEHOMES
* = Not Ready
MISCELLANEOUS
Date
MOBILEHOME UTILITIES (Plans) OK except q's
1. Zoning Requirements -Setbacks -Easements
2. Soils; Special MH Support -Sketch
Date
DECKS, COVERS, CARPORTS, ETC. (Plans) OK except a's
1. Zoning Requirements -Setbacks -Easements _
2. Footings; Size -Depth -Spacing -Connectors
3. Sewer; Location -Test -Fall -C/O -Concrete
3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails
4. Water; Location -Test -Easement Needed (Sketch)
4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing
5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete
5. Alum. Awn.; Columns -Connections -Splice -Decal= Enclosures
6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat.or/. /"L"ft./ /"LPG
6. Carports; Windows -Doors
7. Utility Clearance
7. Elec.
Card -BI
Date Card - BI Date
Card -BI
Date Card -BI Date
Card -BI
Date
Date Card -BI Date
MOBILEHOME INSTALLATION (Plans) OK except N's
1. Zoning Requirements -Setbacks -Easements
Card -BI
Date
Date Card -BI Date
POOLS (Plans) OK except k's
1, Setbacks -Easements
2. Footings; Size -Spacing -Marriage Line
2. Soils; Compaction -Structure Stability
3. Gas; MH Test -Demand -Valve -Connector
4. Electricity; MH Test -Crossovers -Breakers -Clearances
3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining
4. Elec.; Receptacles and Lighting; Distances-GFI
5. Drain; MH Test -Fall -Flex Connector
5. Elec.; Pool Lighting; 15 volts-GFI
6. Water; MH Test -Regulator -Connector
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
7. Water and Sewer Connected -C/0 to Grade -HD Approval
7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater
8. Gas and Electricity Tagged
8. Elec.; Grounding; Equip.w/5'-Circulating Equip. -Pool Lghtg.
Boxes -Enclosures -Panel boards -Ins. to Main in Conduit
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
9. Health Department Approval
-
10. Plumb; Cir. Test -Water Supply Test
Card B -I
Date Card -BI Date
Card -BI
Date Card -BI Date
Card B -I
Date Card -BI Date
. Card -BI
Date Card -BI Date
J = OK
0 = Not OK
- = Not Applicable RESIDENTIAL'(Sing1e and Duplex)
= Not Ready
Date
UNDERFLOOR Plans OK except #'s
Date
FRAMING (Continued)
1.
Zoning requirements -Setbacks -Easements
48.
Property Line Firewall & Openings
2.
Fig., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth
49.
Ext. Doors -One 3'-Check.Garage-3rd story, 2 exits
3.
Ftg., Garage; Soils -Steel- / /" Ftg. Depth
50.
Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
4.
Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth
51.
Plywood on Roof Overhang -Attic Vents -Rafter Outriggers
5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab
52.
Siding -Nailing -Veneer
6.
Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab
53.
Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access
7.
Piers -Fireplace Ft .-Steel
54.
Glazing Area -Glass Protection -Skylights -Plastic
8.
D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test
55.
Shear Walls; Nailing -Bolts
9.
Gas Pipe; Size -Anchors
10.
Water Pipe; Test -Anchors -Regulator -Service Test
11.
Electric; Underground
_
12.
Plenums & Ducts; Clearance -Material -Support -Ins.
13.
Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FINAL (Plans) OK except N's
56. Ext. Steps -Door & Sidelight Protection -Landings
Card -BI
Date
_
Date Card -BI Date
PLUMBING (Permit) OK except N's
14. Water Ht.; Vent -Access -Combustion Air
57.
Smoke Detector
58.
Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor-Ducts-Mech. Protection
15. Water Pipe; Test,& Anchors -Nail Protection
16.
D.W.V.; Test-=Fttngs &Anchors -Nail Protection
59.
Bedroom Exiting
_
17.
Shower'Pan; Test, First Floor -Tub Access
60.
G.F.I. & Bath Fixtures & Tub Access
18.
Test'Tub & Shower, 2nd Floor -Tub Access
61.
Elec. Trim & Subpanel; Breaker Sizes -Labels
_
19.
Pipe; Size & Anchors
62.
Stairs & Rails
_
_Gas
63.
Fireplace or Stove; Clearances -Hearth
Card -BI
Date Card -BI Date
64.
Elec. Outlets at Wood Panel; Int. & Ext.
65.
Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance
Card -BI
Date Card -BI Date
66.
Elec. Outlets & Receptacles at Kit. Counter
Date
ELECTRICAL Permit OK except q's
67.
Garage Fire Door; Swing -Landing -Closer
68.
A.C. Duct in Garage -Damper
-
20.
Fixture & Transformer Clearance -Ins. Protection
69.
Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.-
In Garage; Above Floor-Mech. Protection
21.
22.
Elec. Receptacles Spacing -Lights &Switches at. Doors
Size Boxes & No. of Conductors -Stapled
70.
Plb., Elec. & Mech. Equip. Listed for Location
71.
Elec. Receptacles in Garage; (G.F.I.)-Romex Protec.
23• Romex Installed Close to Edge of Studs & C.J.
24.
Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water
72.
Insulation -Foam -Looked in Attic ❑Yes
73.
Guard Rails &Deck Construction -Post Caps
25.
26.
2 Appliance Wire Size Circuits in Kitchen & Conductor Size
Subleebfeed / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At
74.
Fdn. Vents & Crawl vole Door -Drainage & Wood -Earth Clearance
Looked under Floor ❑ Yes
27
28.
Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al,
Insulated_ Neutral -,Yes ❑No
Service -Riser Conductors & Ground -Main Disconnect
75,
Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No;
Planters ❑Yes []No
76.
Stucco; Brown -Finish
29.
Equip. Clearances: Panels-Motors-Mech. Equip.
77,
A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet
Card B -I
Card B -I
_
30.
Clothes Closet -Light -Shower Light
_-- _-_--__--.
Date _ Card BI Date
Date Card -BI Date
78.
Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs.
79.
Water Well; Disconnect, Electrical, Plumbing
80.
Exterior Elec. Trim; G.F.I. Receptacle -Underground
81.
82.
Ventilation throughout House
Glass Protection
Date
MECHANICAL (Permit) OK except q's
83.
_
Corrections from Previous Inspections
84.
Gas Test -Meters Tagged; Gas -Electric
_
Card -BI
Card -BI
31.
32.
33.--Condensate-0-rain
34.
35.
A. -C. Ducts_ Insulation & Support _ - _
Vent Fan:_Exhaust above Insulation _ - - _
& Overflow; Size & Grade
Furnace -Vent: Access -Comb. Air -Return Air Vent --115V outlet
Attic Access & Platform if Furnace in Attic
_ -
Date Card -BI_ Date _
Date Card -BI Date
85.
Water & Sewer Connected -C/O to Grade -HD Approval
86,
Energy Compliance Certificate -Other Certificates
--
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FRAMING(Plans) OK except q's
Comments at Final:
36.
37.
38.
39.
40.
Sills; Proper Material & Anchors
Walls: Studs -Nailing, Spacing & Bracing -Plates -Sound
Bearing Walls over Girders & Floor Nailing
Draft Stop in Walls (rat proof)
Fire Stop: Furred Ceilings -Stairs -Chases -Tub
_
_
41.
42.
43.
44.
45.
46.
47.
Header & Beam -Size & Bearing
Hangers -Post Caps -Anchors -Connectors
Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthrip -Rfng.
Fireplace Ties or Type A Flue -Fireplace Throat
Attic Access: Size & Romex Protection -Draft Stop -Ins. Baffles
Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
Garage Fire Protection Framing
_
_
(NOTE:Anentrymust be made each time youvisit jobsite)
.. COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS
7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541
APPLICATION AND PERMIT
PERMIT NO
ASSESSOR PARCEL NUMBER
41--33-30
ZONING
BUILDING PERMIT
OWNER .
TELEPHONE
SO. FT. OCC. BUILDING VALUATION
OW ER'S AILING A DRESS
CONTRACTOR'S AME
TELEPHONE
CONTRACTOR'S MAILING ADDRESS
Fireplace
CONSTRUCTION LENDER
UNKNOWN
Total Valuation Is
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
Permit Fee
$
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
$
Energy Plan Checking Fee
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS
,Penalty
$
B4 1mi. SDofEsCherokee Rd, 2 mi E of Hwy 70
Permit tee
$
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Oroville
Solar or heat pump water heater
20.00
LOT NO.
SUBDIVISION NAME
PARCEL MAP
Water piping
5,00
Each qas water heater or vent
5.00
USE OF STRUCTURE
SF ❑ Duplex❑ Mobilehomeba Other
SPECIFY
Gas piping system 1 - 5 outlets
5.00
Building sewer
5.00
Mobile Home S I G I W
10.00ea
TYPE OF WORK
New ❑ Addition ❑ Remodel [:]Uti lities [IInstallation XLX Other ❑
Describe work: Existing Site
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 110.00
Sym �
_
c 6�j
Main service 600V OR LESS
100 AMP OR LESS
10.00
Main service EA. ADO'L 100 AMP
2.50
CONTRACTORS LICENSE LAW
I declare under penalty,of perjury (Check One):
❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and my license is in full force and effect.
License No. Classification
1, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
1dfor sale. (Sec. 7044)
I, as the owner, am exclusively contracting with licensed contract-
ontract-
ors.
ors.(Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONST. DWELLING OCCUP.N) ,
OR ADONS. ACC. BLDGS. / /2 Qsq ft
NEW CONSTR. MULTI -OUTLET
NON.RESID BRANCH CIRC ITS 2.50 ea
POWER APPARATUS e
SINGLE OUTLET CIR.
Ex. Occu zD
p OUTLETS OR FIXTURES eAL&30
FIXED APLNS.FJ
Ex. OCCUp. OUTLETS P(RESID )REA.1 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
Misc. �Yirin 15.00
9
Permit Fee $
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Contractor
MECHANICAL PERMIT
FiIingFee 10.00
Heating
Cooling
Hood
3.00
Ventilation
permit Fee
$
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the County of
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and expenses which may in any way accrue
agai aid County ' onsequence o the granting of this permit. /
X 1/ Date �'_2 6 �(o
Signa, r of Applicant — caner❑ onrrac o Agent
An OS A permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
Energy Inspection Fee $
TOTAL PERMIT FEE $ D
occu P.
CONST.TYPc
I
I FLOo
PARCEL
PD
I HD
ISSUE
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRECTO"F PUBLIC
By
PE T EXPIRES Date _
the applicable provi-
resolutions to do
fees have been paid.
WORKS
Date 7 7-7-1?�-
— Z7
/�
R '
eceipt No. �7 O
WHITE-D.P.W.. YELLOW -ASSESSOR, PINK-INSPECTOR.GOLOENROa-APPLICANT
ly r
COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS - BUILDING DIVISION
7 COUNTY CENTER DRIVE - OROVILLE,'CAL1FOR'NIA 95965 - TELEPHONE: 916/53411541
1.
PERMITtAPPLICATION,DATA SHEET
Permit No. 1 /
OWNER �� V A. P. No.
Proposed Building Use
Permit Fee Based Upon: / Complete Contract Price DPW Valuation
a
Other (Explain)
Building Inspector Date
At time of permit application, I was advised the following.data must be submitted prior to permit processing
and/or issuance: DATE RECEIVED APPROVED
1. All items have been submitted. . . . . . . . . . . .
2., Plot plans in duplicate/triplicate. . . . . . . . . . .
3. Complete plans in duplicate/triplicate. . . . . . . . .
4. Complete engineered plans and calcs. . . . . . . . . .
5. Plans with Energy Design Compliance Statement. . . . . .
6. CUSD ''Fees Paid'' Stamp on Floor Plan . . . . . . . .
7 Statement of Intent for Non -Heated and AC Buildings.
8. Fees of $ . . . . . . . .
Letter of signature authorizati // . . .
Sanitation approval from— Uroui Z!f'- Health Dept.
11. Planning approval for (A) Use: (B) Parking:
12. Certificate of Workmen's Compensation Insurance. . . . . .
13. Contractor's License Information (no., name style, classif.)
14. Owner -Builder Verification (Given to owner❑, Mail to owner ❑ )
--��Improvements may be required. .. . .. ...
1 Mobilehome Installation Data. . • • . • . . .
17. Pre -Inspection for Required- BuildingPre-Insp
request to QQ�Qte)
p q Building Inspector .�
18. RecoOther
���hU'�u��ons�ruct� o�m approvaierequired prior o occupancy
19. Other •
Whe ou issue the permit, process as follows- Mai,IAo owner. Mail to contractor.
`{
Telephone 53Y -2 elV
and hold for pickup at () office. Deliver w/inspector.
Other
Applicant" - Date
Copy of plans sent Health Dept., Fire Dept., Other ��''c Date
During the plan checking process, the following data must be submitted prior to permit issuance:
(For required items not checked above at time of application, circle item.)
1. Index permit for above Items No. r
2. Additional items required:
r
(Contractor, Designer, Owner) was advised of above required data by
By
Plans checked by.
Plans approved by
Other
Copy–DPW
Telephone _
Date
Date
i I Other
Pate
To: Building Department r q
From: ?�vironmental Health
Subject: Sanitation Clearance
Owner U Location AP//
Plan Approved for: Sewage disposal c74\ water supply
Hold final for: water supply
Final clearance O.K. for: eater supply
Clearance for bedroom mobile home. Other.
Tanitarian Date
OArc e i
A permit will be require'c the.
installation of the mobi ehome. I
5
A.P. Lli-33 30
1
I .
A64 -00`r`
Nd�sc
v
. s
0
S r
700
u���ieGrr.W p
E`ec i Ri c
A setback of 5 ft. from ft;
property lines and a sotbach
of 50ft. from the road
centerline shall be clear of
structures or equipment except
for a 2 ft. eave overhang.
C� ship
Shall 9e in
•� A!!
Materials :& rl; , # Prc ^.t"ccs and
N+�TE, RFcrjrini'e ,_ ��,�:se in t r,'
ante w th f;,r ^.t,�. I Codes and
escriher. .! -In Ica�
of d �ua,►tY 1' Plun� incl o:
Uniform ding�
On mmiional Electr• A /
/L
This of plans and specifications MUST 6e
dept on the job of till times and it is unlawful to
snake any•changes or ol+areticns on some without
written permission from +he Department of Public
ww� r.ni.enty_ of Rut+e. --
S
ility connectii ns shall be withi14
4 ft. of the m home, e11bOr
directly behind or within the four
half of the roadside (left) of -the
mobilehome.
su� 90
�n
BUI,BUTTE
DING DEPARTMENT
APPROVED
m
TTU8
yl,juOD
w
BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS
7 County Center Drive, Oroville, CA
PHONE: 534-4541
MOBILEHOME INSTALLATION SHEET
1. Owner's Name: �Lxe
2. Installer's Name
3. Is the site currently under permit? Yes F] No a
_ (If yes,
furnish permit number
is the
) OR
Is the site an
existing site?
Yes
No
(If yes,
furnish two plot plans.)
mobilehome
site service rating? --------------
4. Will the mobilehome be located at least 5 ft. away from septic. tank and leach
fields and clear of all setbacks and easements? Yes Fx] No F]
(If no, clarify
5.
What
is the
mobilehome
electrical rating? ---------------
A9 D
Amps
6.
What
is the
mobilehome
site service rating? --------------
/,5_ 6)
Amps
7.
What
is the
mobilehome
site circuit breaker rating? -----
/0 O
Amps
8. Is there any other electric load to be served by the
mobilehome site service? -------------------------------- Yes F No
(If yes, identify the load and size: (Load) (Amps)
9. What is the mobilehome site gas pipe size?---�----- (in.)
YP g ? -------------------
10. What is the type of as service. � Natural F] LPG '®
11. What is the gas pipe length from meter or tank to the
mobilehome?---------------------------------------------
12.
---------------------------------12. What is the mobilehome gas demand? ---------------------- (BTU)
*(This information not required if pipe.length less than 6 ft. on
.natural gas or less than.50 ft. on LPG.)
BUTTE COUNTY
BUILDING DEPARTMENT
APPROVED ,��
Mobilehome Mfr.
MOBILEHOME SUPPORT DATA
r; 4.
If other than single wide,
furnish -Setup Model No. Year
Width `1i (ft.) Box Length 5_6 (ft.) Tagalong or Expando Size ft. x ft.
On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation
manual and structural setup sheets (if not on file with the County of Butte).
FOOTINGS (check one)❑ 1. Wood -pressure treated or foundation grade.F-1 2. Other (specify)
SUPPORTS (check one) al.• Concrete block. RX
Other (specify)
Pier Footing Sizes and Locations
SINGLE -WIDE
MULTI -WIDE
Line 1
Main Beams
Lines
Line 1 Piers:
Size-Min.------------
Spacing-Max.
From Ends -Max. -------
Line 2 Piers:
Size-Min-------------
Spacing-Max ----------
From Ends -Max .-----=-
Line 3 Roof Loads:
Size -Min -------------
Location (From Front)
Main Beams
Tag or Triple
Line 1
Line 1 Openings:
Size -Min. ------------------ „x
Each Side of Openings
With Width over ---------
Line 3 Piers: (Under Bearing Wall Only)
Size -Min .------------------
��x
Spacing -Max.---------------
From Ends -Max.------------- �_
e v riers•
Size -Min .------------
'k "
Spacing -Max----------
From Ends -Max. --; ----
e 5 Piers: (Under Bearing Walls.On y
Size -Min .------------------
Spacing -Max.--------------- r_ n
From Ends -Max .-------------
Line 5 Roof Wads:
Size -Min.------------
F
ux..Xnx.11xa nn nxLocation (From Front)
TV1:;;ti.iTil Aq:!(i �1V. lC]j t V
COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS
7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541
APPLICATION AND PERMIT
PERMIT NO�
ASSESSOR PARCEL NUMBER
41-33-30
ZONING
U
v
BUILDING PERMIT
OWNER
Spring Valley Minerals
TELEPHONE
SQ. FT. OCC. BUILDING VALUATION
OWNER'S MAILING ADDRESS
Rt 7, 287L, Oroville
CONTRACTOR'S NAME
C
TELEPHONE
CON ACTOR'S MAILING ADDRESS
Fireplace
CONSTRUCTION LENDER
UNKNOWN
Total Valuation is
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
Permit Fee
$
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
$
Energy Plan Checking Fee
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Penalty
$
BUILDING ADDRESS
1 mi S of Cherokee Rd 2 mi E of Hwy 70
Permit tee
$
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Orovillp
Solar or heat pump water heater
20.00
LOT NO.
SUBDIVISION NAME PARCEL MAP
Water piping
5.00
Each qas water heater or vent
5.00
USE OF STRUCTURE
SF ElDuplex❑ Mobilehome� Other SPECIFY
Gas piping system 1 - 5 outlets
5.00
Building sewer
5.00
Mobile Home S rG
10.00 ea
TYPE OF WORK
New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation[] Other QX
Describe work: Qas Line for ExistingS to
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
Main service 100 AMP V OR LESS
10.00
Main service EA. ADD -L 100 AMP
2.50
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (check one):
F1NON.R
I am licensed under provisions of Chapt. 9, Div. 3 of the Bushes$
and Professions Code and my license is in full force and effect.
License No. Classification
F1 1, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEW CONST. DWELLING OCCUP.61 ,
OR ACDNS. (ACC. BLDGS. /z¢sgft
NEW CONST R.UL 2,50 ea
ESID BRANCCHH CCIRRCCU ITS
POWER APPARATUS e
(SINGLE OUTLET CIR. I
Ex. Occup(OUTLETS OR FIXTURES 20®502
IIAL030
Ex. Occup. OUTLETS (PRESID )FIXED APLNS.REA.I 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
Misc. Iyirin 15.00
9
Permit Fee $
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
❑ I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
p�of Consent to Self -Insure.
I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with -such
provisions or this permit shall be deemed revoked.
Contractor
MECHANICAL PERMIT
Filing Fee 10.00
Heating
Cooling
g
Hood
3.00
Ventilation
permit Fee
$
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the Countyot
Butte to enter upon the above-mentioned property for inspection purposes.
1 also agree to save, indemnify and keep harmless the County of Butte against
all liabilities, judgments, costs, and expenses which may in any way accrue
again t said Count copsequence of the granting of this permit.
X e --CIS _ a
Signa u of Applican — Owner Contractor Agent&
An 0 A permit is required For excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee $
Energy Inspection Fee $
TOTAL PERMIT FEE $ pJv �O
occUP.
CONST.TYPE
I
I FLOOD
PARCEL
PD
HD
390E
This permit is hereby issued under the applicable provi-
sions of the Butte County Code and/or resolutions to do
work indicated above for which fees have been paid.
TO PUB ORKS
By.
PERMIT EXPIRES Date-
Receipt No.
WHITE-O.P.W.. YELLOW -ASSESSOR, PINK -INSPECTOR. GOLDENROD -APPLICANT