Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
042-130-070
042-130-070 PERMIT#915- 044,MERRIMAN, Chuck & Linda2799 Oak Way, ChicoCont; Gard Anderson tNew. Single Family. , _. I - � /�� 1.)042-130-070 PERMIT#96-1591MERRIMAN, Charles2799 Oak Way, Chico v/Cont; Adonis Pools & SplasNew Pr i'Swimming Pool I 10 0-070 01-0166 2799 Oak Way, o si Cont: Dan Heal� Gas line for futur log ligghte ME�TO -070 - 01-0193 FAMILY TRUST 2799 OAK W ICO CONTR: LAMBERT RY V/ 0 CLEARANCE GAS FIREPLA BO J�w042-130-070 OAK XVAY _ ----_-_Application naWayne A. Anderson T' ~rI BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 1 WEBSITE: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 2799 OAK WAY Owner: Permit No: B07-1920 APN: 042-130-070 MORGAN, JAMES Issued Date: 09/11/2007 By KCG Permit type: MISCELLANEOUS 2799 OAK WAY Subtype: Phtovtaic Sys Roof CHICO, CA 95973 Expiration Date: 09/10/2008 Description: ROOF MOUNT SOLAR SYSTEM (530) 828-2626 Occupancy: Zoning: Contractor Applicant: Square Footage: ALTERNATIVE ENERGY SYSTEMS INC ALTERNATIVE ENERGY SYS Building Garage RemdUAddn P O BOX 9231 P O BOX 9231 CHICO, CA 959279231 CHICO, CA 959279231 (530) 345-6980 (530) 345-6980 Other Porch/Patio Total FEE INFORMATION DBMSC Photovoltaic System $408.93 Total Charged: $408.93 Fees Paid: $408.93 Balance Due: $0.00 Receipt No: B4572 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Nance) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License ALTERNATIVE ENERGY SYSTE 853351 / C10 / 01/31/2009 Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) is in full force and effect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects X 09/11/2007 the applicant to a civil penalty of not more than five hundred dollars [$500]; Please check one of the following: Contractor's Signature Date ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of the property, who builds or improves thereon, and who does WORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: the work himself or herself or through his or her own employees, provided that such improvements ❑I HAVE AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). 1paHAVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by ❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Provessions Code: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. The Contractors License Law dows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Carrier: STATE FUND policy Number: 713-00194h19 Exp. Date:05/01/2008 Contractor's License Law.). (This section need not be completed a the permit is or one url rlars ($100)oror es— ed dol ❑ I AM EXEMPT under Section B. & P.C. for this reason: ❑I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California, and agree that if I should become subject to the workers' X 09/11/2007 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those Owners Signature Date provisions. X 09/11/2007 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building Signature Date WARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, injury, including death, and property damage caused by, arising out of, or in any way connected with the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. County to enter the above mentioned property for inspection purposes. I hereby certify that I am the properly owner am authorized to on the property owners behalf. 09/11/2007 CONSTRUCTION LENDING AGENCY I HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name Of Permittee [SIGN] Print Date the performance of the work for which this permit is issued. (3097 civ, code) Owner ontractor Oji; Agent for Owner Agent for Contractor FILE COPY Lenders Address City State Zip SCALE: .015" = 1' BD7• Ig2D PLOT PLAN -BUILDING DIVISION APPROVE®' �i le �o o��- (�Dol -------------------- 543'-----=----------------I A2N � I' INVERTER - LOCATED INSIDE REAR OF GARAGE EXISTING I HOME � N w � co I I SOLAR PANELS 220' FLUSHMOUNTED PER , MANUFACTURERS INSTRUCTIONS Q UJ I PGE MAIN METER o I -----------283'------------ N I ------ -------378'------------- —J BD7• Ig2D PLOT PLAN -BUILDING DIVISION APPROVE®' �i le �o o��- (�Dol I ARRAY DEAD LOAD CALCULATION ITEM. PANEL RAIL STRUT TILT LEGS # EA 27 8.74 0 0 LENGTH (FT) 17 16 WEIGHT/FT (LB) 1 1.9 WEIGHT EA (LB) 33 5 WEIGHT/ITEM (LB) 891 148.58 - 0 SUM 1,040 LB AREA 405 FT"2 WEIGHT/FT"2 2.6 PSF Location: JIM MORGAN 2799 OAK WAY CHICO, C A 95973 Designed & Installed by: 'ALTERNATIVE ENERGY SYSTEMS INC PO Box 9231 Chico, CA 95927 4 !DIVISION A ��S® BUTTE COUNTY 3UILDING DIVISION APOPOvED 5KWATT SOLAR GENERATOR LINE ITEM DIAGRAM The SunPower SPR-205-BLK is designed specifically for on -grid residential systems where a combination of high module efficiency and outstanding appearance is desirable. Utilizing 72 series -connected A-300 solar cells, the SPR-205-BLK delivers industry-leading power density in a unique all -black module package with exceptionally uniform appearance. SunPower modules—innovative design, proven materials, outstanding performance. • All -black module package eliminates harsh reflections and other noticeable cosmetic module features to provide optimum array appearance • Unique all -back contact solar cells with conversion efficiency up to 21.5`Y • Low voltage temperature coefficient, exceptional low -light performance, and high sensitivity to light across the entire solar spectrum maximize yearly energy delivery • Highest quality, high -transmission tempered glass provides enhanced stiffness and impact resistance • Aerospace style cell interconnects with in -plane strain relief provide extremely high reliability • Advanced EVA encapsulation system with multi -layer backsheet meets the most stringent safety requirements for high-voltage operation • A sturdy, black anodized aluminum frame allows modules to be easily roof -mounted with a wide variety of standard mounting systems 0 May 2007 SunPower Corporation. All rights reserved. specifications included in this dmosheet aro subject to change without rwtice. SunPower Corporation® 1.877.SUN.0123 Email: sales@sunpowercorp.com Engineered in California S!R-205-BLK RESIDENTIAL PV MODULE An unequaled combination of power and grace t j` COUN BUILDING DIVISION UL LIMD UL 1703, Clas C FirKMOVED t � ) IEC 61215, Safety Class II Certified www.sunpo-rvercorp.can Document# 001.12153 Rev 'A SPR-205-BLK " RESIDENTIAL PV MODULE ELECTRICAL CHARACTERISTICS AT STANDARD TEST. CONDITIONS (STC) STC is defined as: irradiance of 1000W/m2, spectrum AM,,l .5g and cell temperature of 25°C a' , Peak Power' -9 Pmax 205W Rated Voltage VmP 40.OV Rated Current Imp 5.13A Open Circuit Voltage V. 47.8V Short Circuit Current I,c 5.53A ` Series Fuse Rating 15A Maximum System Voltage 600V (UL) r . c: ..... _....--- 1 1000 1OOOV (IEC) Temperature Coefficients Power -0.38%/aC .__............._j Voltage (V«) -136.8mV/°C Current(1,,)3.5mA/aC Module Efficiency 16.5% p Peak Power per Unit Area 15.3W/sq.h. ; 165W/m' PTC Rating 189W .. IVB CURVE 6.0- r . c: ..... _....--- 1 1000 - Watts -._.. --I m2; -................._.- '--"-i'-'---------- SeC; AM 1. S9 .......... .__............._j ..__...._........_..---'-- - a.0- -- -- -- '— ---- ---- a 2:5 r s- , S1.0.4 .. .................. ............. _...... _.... _... .... ----._....... ..................... _.......... _ ......._.. - -- ----- _-_.... . ................ ....... _... .._..... _....... ...... --- ._il.! LS..L ...1.!_+ L�1_.i_r.LL. 4....1-� �11:•.-;!-0 w 5 10 is 20 25 30 35 40 45 s0 volts Peak Power Tolerance: +/- 5% 2 Power guaranteed for 25 years. See SunPower limited Warranty for details. i MECHANICAL SPECIFICATIONS Length 61.39 in x 31.42 in [1559 mm x 798mm] Thickness, including junction box 1.81 in [46 mm] Weight, 33 lbs [15 kg] DIMENSIONS"„ in[nnn] a S} -4 r.;'sf Lri7.Od 47.24 0.1614.21 I' 11801 112001 1C—edt J 2%01 10.21 ' I Groii4) 29.69 31.42 17541 V981 I x . s 36.02 12.69 1.81 19151 13221 61.39 8%0.2616.61 115591 1461 0.1614.21 lC—dI wil ®Aby 2007 SunPower corporation. All rights reserved. specifications included in this dalasheM ore subject to change without nonce. 1. D1�� D�� %` ' �ln.001.12153 Rev'A SunPower Corporation®.r V 1 VVV �•Y 1.877.SUN.0123 Email: sales@sunpowercorp.com www.sunpo rcor"p:c rgtr,�(1,�ED s ,Engineered in California r � i Installation Manual 808.1 SunFrame@ Planning and Assembly for Threaded Slot Rail UMIRAc® Using standoffs with L -foot adjusting sliders Two-piece aluminum standoffs may be used with footing of each standoff to the slider using the slider's 3/9 -inch hex - sliders, although flashings may not be available to cover the head bolt. Note that L -feet are positioned long side up on the entire length of the slider. Use the bases of the standoffs lowest rows and with long side down in subsequent rows— only in the lowest row. In subsequent rows, attach the shaft in the same manner as an installation with no standoffs. With standoffs of equal length, orient L foot to compensate for If the standoff supporting the lowest rail is 1 inch taller than height difference. ..the standoffs on the footing sliders, place both L feet in the same orientation—either both long side up or both short side up. a [a met i This example assumes a rail seven times the length of the shaded areas. If more than one splice is used, be sure the footing spacing (A). A splice may be located in any of the combination does not violate Requirements 5, 6, or 7. Footing and splicing requirements The following criteria are required for sound installations While short sections of rail are structurally permissable, they can usually be avoided by effective planning, which also pro- motes superior aesthetics. See "Material planning for rails and cap strips" (p. 13). The installer is solely responsible for ensuring that the roof and its structural members can support the array and its live loads. For rail lengths exceeding 48 feet, thermal expansion joints may be necessary. Please contact UniRac. 1. Footing spacing along the rail (A in illustration above) is determined by wind loading (see pp. 5-8, especially step 4). Foot spacing must never exceed 48 inches. . 3. Do not locate a splice in the center third of the span between two adjacent feet. 4. In a spliced length of rail, all end sections must be sup- ported by no less than two L -feet. 5. All interior rail sections must be supported by no less than one L -foot. 6. Interior rail sections supported by only one L -foot must be adjacent, on at least one side, to a rail section sup - .ported by no less than two L -feet. 7. Rail sections longer than half the footing spacing re- quire no fewer than two L -feet. 2. Overhang (B) must be no more than half the length of Rafters the maximum footing spacing (A). For example, if Span A is 32 inches, Overhang B should not exceed 16 inches. i �Stringer ; ------- --_-_' Aik Rail Modules should always be fully supported by rails. In other words, modules should never overhang rails. This is especially critical when supporting the short side of a non -rectangular module. When a rail supports a pair of non- rectangular modules by themselves (right), it must be supported by at least two L feet. The rail should be at least 14 and no more than 24 inches long, which will likely require a stringer between rafters to ensure proper footings. Non-rec)gpgular modules BUILDING DIVIbl-up, it 000nV D UNMAQ® Installation Manual 808.1 SunFrame®Planning and Assembly for Threaded Slot Rail 3. Laying out and installing the next row of L -feet With L -feet only: Position the second row of L -feet in accor- dance with Figure 10. Ensure that you measure between the lower bolt hole centers of each row of L -feet. Install the second row of L -feet in the same manner and orientation as the first row, but leave the lag screws a half turn loose. Be aware of the set-up time of your sealant; the L -feet will not be fully tight- ened until Step. 4. With L -foot adjusting sliders: Use a chalk line to mark the position of the slider center holes of the next row. The illustra- tion below provides spacing guidelines. The length of the module (A in Fig. 11) includes any protrusions, such as lips or pan -head screws in its frame. Attach and seal L -foot adjusting slider: Install lower lag first, footing bolt next, and upper lag last. Attach an L -foot with its short side up to each slider. Roof peak -� Module length +'/." (hole to hole) Figure 10. L foot separation. See the note on module length in the caption of Figure 4 (p. 9). A = module length A Align slider Acenter hole to chalk line Lowest row of L -feet (no footing sliders) A + 1 3/16" A + 2 '/4" 4. Installing the second rails With L -feet only (Fig. 12): Install and align the second rail in the same manner and orientation as the first rail. After rail alignment, securely tighten the rail mounting bolts to between 30 and 35 foot-pounds. Lay one module in place at one end of the rails, and snug the upper rail (Fig. 12) toward the lower rail, leaving no gap between the ends of the modules and either rail. (If pan -head screw heads represent the true end of the modules, be sure the screw heads touch the rails on both ends.) Securely tighten the lag screw on that end. Slide the module down the rails, snugging the rails and tightening the remaining lag screws as you go. With L -foot adjusting sliders: Install rails on first and second rows of L -feet. Verify spacing by placing a module onto the rails at several points along the row. Adjust L -foot positions as needed. 5. Installing remaining L -feet and rails Install the L -feet and the rails for the remaining rows, follow- ing Steps 3 and 4. You may use the same module to space all the rows. When complete, confirm that: Page 12 >>� Align slider A - 3'/4" center hole to chalk line A + 3/4„ Figure 11. If you are usingL foot adjusting sliders, this spacing between rows places L feet at the center of their adjustment range. Snug Module ; , •, i Lag screw Lag screw' tight) {half'tur'n loose) '( Figure 12. Position and secure top rail. • All rails are fitted and aligned. • All footing bolts and lag screws are secure. • The module used for fitting is resting (but not se- cured) in the highest row. BUTTE COUNTY BUILDING DIMS APPROVED Installation Manual 808.1 SunFrame® Planning and Assembly for Threaded Slot Rail VNORACM Material planning for rails and cap strips Trim line (array edge);; 1 Preplanning material use for your particular array can prevent assemblies and cap strip assemblies need to be cut and Trim line (array edge$. >� structural or asthetic problems, particularly those caused by spliced from 192 -inch sections of rail and cap strip. The • • V 112" • very short lengths of rail or cap strip. This example illustrates example illustrates one means of doing so, without violating one approach. structural requirements or aesthetic goals. if_ Stuctural requirements for rails are detailed in "Footing Rail segments come from five 192 -inch lengths, lettered A and splicing requirements" (p.11). Structurally, cap strips thru E. Rail A, for example, is cut into two 96 -inch segments, require: with one segment spliced into each of the first two rails. • A screw in every prepunched hole (which occur Similarly, five 192 -inch cap strips are designated V through it f It every 8 inches, beginning 4 inches from the ends of Z. _ 1i !i� •^ • the rails). All cap strip segments are cut at the midpoint between • • W 112"�• • One screw 4 inches or less from the each end prepunched screw holes. For each rail, start with the cap °' X 96" ; ; 2nd cap strip •,, of every rail segment. Wherever there is no strip segment that crosses the array center line, and position (i prepunched hole within 4 inches of an end of a over the center line so that the appropriate holes are spaced ( segment, drill a 1/4 -inch hole 2 inches from the end equally on either side. It of the segment and install a cap strip screw. (In -' Position each cap strip onto its rail and mark its trim point. most cases, you can avoid this situation with good Remove and trim before final mounting. 11, ° Y 128" I •9I , 1 material planning.) Preliminary footing and splice positions must be Structural requirements always take precedence, but usually checked against structural requirements in "Footing good planning can also achieve both material conservation , . ; and splicing requirements" (p.11). In this example, and superior aesthetics. This example conserves material the center of the array is offset 2 inches from the center e and achieves two specific aesthetic goals: rafter. This prevents rail splices BD (3rd rail) and CE AM • Cap strip screws must align across the rails. (4th rail) from falling too close to the center of the spans • W 80" J ; C ; r I Z 128" i 1 between footings (Requirement 3, p. 11). Because foot- A 96" • End screws must be equidistant from both sides of ings are not visible from ground level, there is negligible ; ; the array. aesthetic loss. „ li The example assumes an array of three rows, each holding it 11 1 li( 11 five modules 41 inches wide. Thus, four 205 -inch rail Array center line ii Usable remainder: D, 70"; E, 70'; Y, 64"; Z, 64" ii ii 91 ii — Trim line (array edge);; 1 Trim line (array edge$. >� • • V 112" • ; ; X 96"' 1 st cap strip •j, if_ 11 I t 11 C 83" ; ; ; ; ii E 122" 4th rail it f It li li _ 1i !i� •^ • iI 11 ii ii 1i • • W 112"�• " • •11 ." I � •� °' X 96" ; ; 2nd cap strip •,, r)) B 83" (i i r I D 12Z' 3rd rail ( It : -- 3rd cap strip 2nd rail 99 1 ., 1 • V 80" •! I •ii � 11, ° Y 128" I •9I , 1 1 A 96" i ii ti C 109., .I 1 , i AM 4th cap strip • W 80" J ; C ; r I Z 128" i 1 A 96" ; ; ; ; ; ; B 109" ; ; 1 st rail „ li it 11 1 li( 11 li II 11 It Usable remainder: D, 70"; E, 70'; Y, 64"; Z, 64" 9U-ffE ON 'LDING DIVISION -. 13 • -' VN®RAC® Installation Manual'808.'1 : SunFrame®:Planning and Assembly for Threaded Slot Rail 6. Securing the first module Gather sufficient lengths of cap strip pp -..5 Pi screws PermiSsable overhang ' to cover the length of the first rail. Formodule width maximum visual appeal and materialg. m conservation see"Material planning for dr( rails and cap strips".(p13)m Slide the first module into final,position at one end of the array. Lay the remaining . r� modules in the toprow, leaving a a g g P ' ` WW=,� about a foot wide between the first and SE cond modules(Fig. 13)• , w s ' �gax a " The temPo.rarY gap allows the installer to, %rte .place one of his feet between modules. He' can access the section ofthe cap strip he, 51 needs. to secure while_ leaning toward thet a peak of the roof.For the:ame being, the o not ins all s u eco cap step until lower Iasi module may overhang the rail b u Y g Y Pf� modules ore placed to one third its width.. Attach the end of the cap striwith the cap strip screws (Fig. 13, inset), so Figure 13 Begin cap strip installation. ' that'the upper end of the'firstmodule is ; . . secure _ ' The structural integrity of your array,requires that cap strip screws fully engage the threaded rail:"Use the cap 2 Ins oil screws strip screws supplied with your cap strips. Any substitute F screws must be 1/4-20 Type F• thread cutting (1878 stainless ''€ steel).and the correct length."See. Table 4'(pg ,15) to match screw length to the size cap strip in your installation. l 5tide \ Every cap strip segment must have a cap strip screw 4.;, by € x F _ ., �Steppmggap ; . inches or lessfrom each end. If the nearest predrilled E' v hole falls more than 4 inches from any end, drilla. 's " 1 1/4 -inch hole 2 inches from the end and install an additional S screw. r' Figure 14. Position and secure modules one by one. Wherever it is necessary to make a new cap, strip hole," drill a 1/4 -inch hole ' .b. efore installingthecap strip screw.,' 7. Installing the remaining modules in the.top row Slide the next module into final position and install the'screws to secure it (Fig. 14):For a neat installation, use cable ties to • k W Slide ands _� attach excess wiring to the rail beneath the flanges. UniRdc's k ecureaone „ A' �' cable ties can be attached to the SunFrame rail by drilling a # z °z bygone , 1/4 -inch hole in the rail and pushing the end of the tie into the i hole. 1 st Continue the process until all. modules in the top row, are in Stepping gape. final place and secured from the top. When complete, every r \, \ prepunched hole:in the cap strip will be secured by a screw, —! and•the top end of the first row of modules willbe secure. Figure 15'; As modules slide into place, the stepping gap shifts, 8. Installing the remaining" modules row by row always allowing access to the section of cap strip being secured. - ' Repeat Steps 6 and 7 for the remaing rows {Fig. 15). Each, subsequent cap strip will secure the tops to the modules being installed and the bottoms of the modules in the row above. " Place the final cap strip in the lowest rail,`.securing the•bottom of the lowest module row. (��jj� L `-�i�Un\i N W qH jp� \\1flfl1$$�`� aaq� /j ®"i 14 PR U AP i r ,iiY Installation Manual 808.1 SunFrame® Planning and Assembly for Threaded Slot Rail UN®RACO 9. Installing the end caps Attach the end caps to the ends of the rails by securing with the truss head sheet metal screws provided (Fig. 16). Figure 16. End cap installation. Table 4: PV module, cap strip, and cap strip screw compatibility To ensure code compliance and a structurally sound array, cap strip sizes and cap strip screw lengths must be compatible with the PV modules in your installation. All cap strip screws must be %,-20Type F thread cutting (18-8 stainless steel). ' Module thickness or type Cap strip Required screw inches mm cross section Cap strip size length (inches) 1.34-1.42 34-36 el— C 3/," 1.50-1.57 38-40 -5--M D 3/," 1.77-1.85 45-47TT F I %," 1.93-2.01 49-51IT E I A" Sharp lipped modules G I" Sanyo lipped modules H 3/," P.'c 15 UN®RAW Installation Manual 808.1 ' SunFrame®Planning and Assembly for Threaded Slot Rail Frequently asked questions about standoffs and roof variations How high above the roof is a SunFrame array? The answer depends on the orientation of your L -feet and the length of your standoffs, if used. See the illustration ap- propriate to your installation. How can I seal the roof penetration required when standoffs are lagged below the roofing material? Many types and brands of flashing can be used with Sun - Frame. UniRac offers a Oatey® "No -Calk" flashings for its steel standoffs and Oatey® or UniRac flashings for its aluminum two-piece standoffs. See our SunFrame Pro -Pak Price List. How do I attach SunFrame to a standing -seam metal roof? A good solution comes from Metal Roof Innovations, Ltd. (MRI). It manufactures the S-5!' clamp, designed to attach a wide variety of products to most standing -seam metal roofs. It is an elegant solution that eliminates flashings and penetrations altogether. Wl Module thickness varies SunFrame L -feet will mount to the top of the S-5! clamps with the 3/8 -inch stainless steel bolt provided with the S-5! See www.s-5solutions.com for different clamp models and details regarding installation. When using S-5! clamps, make sure that there are enough clamp/L-feet attachments to the metal roof to meet the Metal Roof Manufacturers' and MRI specifications regarding wind loads, etc. Module thickness r varies 2'/4-±/8- 7/g-+ 1/8- 2'/4-± '/8 - Standoff height (3", 4", 6", or 7 - all ± 1/8-) - i . I— 10 year limited Product Warranty, 5 year limited Finish Warranty UniRac, Inc., warrants to the original purchaser ("Purchaser") of product(s) that it manufactures ("Product") at the original installation site that the Product shall be free from defects in material and workmanship for a period often (10) years, except for the anodized finish, which finish shall be free from visible peeling, or cracking or chalking under normal atmospheric conditions for a period of five (5) years, from the earlier of 1) the date the installation of the Product is completed, or 2) 30 days after the purchase of the Product by the original Purchaser ("Finish Warranty"). The Finish Warranty does not apply to any foreign residue deposited on the finish. All installations in corrosive atmospheric conditions are excluded.The Finish Warranty isVOID if c I .'t� Pn, 16 1411 Broadway NE, Albuquerque NM 87102-1545 USA • 505.242.6411 • Fax 505.242.6412 the practices specified byAAMA 609 & 610-02 — "Cleaning and Maintenance for Architecturally Finished Aluminum" (www.aamanetorg) are not followed by Purchaser.This Warranty does not cover damage to the Product that occurs during its shipment, storage, or installation. This Warranty shall beVOID if installation of the Product is not performed in accordance with UniRac's written installation instructions, or if the Product has been modified, repaired, or reworked in a manner not previously authorized by UniRac IN WRITING, or if the Product is installed in an environment for which it was not designed. UniRac shall not be liable for consequential, contingent or incidental damages arising out of the use of the Product by Purchaser under any circumstances. Module thickness varies MI 7/8-± 1/8- If within the specified Warranty periods the Product shall be reasonably proven to be defective, then UniRac shall repair or replace the defective Product, or any part thereof, in UniRac's sole discretion. Such repair or replacement shall completely satisfy and discharge all of UniRac's liability with respect to this limited Warranty. Under no circumstances shall UniRac be liable for special, indirect or consequential damages arising out of or related to use by Purchaser of the Product. Manufacturers of related items, such as PV modules and flashings, may provide written warranties of their own. UniRac's limited Warranty covers only its Product, and not any related items. THE STANDARD IN PV MOUNTING STRUCTURES" e: Xantrex GT Series Grid Tie Solar Inverters Xantrex photovoltaic string inverters offer high efficiency, clean aesthetics, high reliability, as well as lower installed cost, through time -saving installation and included features.The result is a high-performance inverter that makes utility -interactive installations easier and more cost effective. Technology ;i > ► Proven high -frequency design in a compact enclosure ► Integrated DC/AC disconnect that is NEC compliant to eliminate the need for external DC (PV) and in some jurisdictions, AC disconnects ; ► Large heat sink offers extraordinary heat dispersion without the need for a cooling fan; :q K% y ► Backlit, two-line, 16 -character liquid crystal display (LCD) provides instantane6us'pc,' daily and lifetime energy production, photovoltaic array voltage and current, utility voltage and frequency; time online`- "selling" today, fault messages, and installer customized screens ► Bright LED indicators provide system status at -a -glance q ls LCD vibration sensor allows the tap of a finger to tum backlight on and to cycle through display screens ► Integrated R5232 and XanbusTm R145 communication ports f ; " s7 M s ► Free PC software for remote monitoring and system troubleshooting available;online) , :�►� Installation l ► Flexible module selection and sizing due to wide PV input MPPT tracking voltage range, y'r " ^G ► Lightweight and versatile mounting bracket simplifies installation ► Modular design allows inverters to be mounted side-by-side, using each wiring box as a wiring raceway ► Easy access DC (photovoltaic) and AC (utility) terminal block simplifies wiring. ► Integrated, lockable AC/DC disconnect saves installation time and balance of system component cost ► Rugged NEMA 311 inverter enclosure allows reliable outdoor and indoor installations Performance ► Best -in -class efficiency to maximize investment of solar system ► Accurate MPPT tracking ensures maximum energy harvest under any condition 1;• , ► Excellent thermal performance, ► FCC Part B compliance means less potential interference with communication, radio, and consumer electronics Serviceability` ► 10 -year standard warranty l, Sealed inverter enclosure can be separated from the wiring box allowing DC/AC connections to remain intact in the unlikely event the inverter needs to be serviced;- i A 02007 Xanbu Technology Inc. AU dghts reserved.Xantrex is a registered tredereark ofXantrex International. Pdnted In Canada. •o ""'. �'!" xantrex GT SERIES WARRA?M 1 rc�Aas Standard 10 -year warranty Xantrex Technology Inc. Customer Serviceffechnical Support customerservice@xantrex.com Toll free: 1-800-670-0707 c, m 170 PHOTOVOLTAIC CSA 1. C us 077-01 POWER INVERTER www.xantrex.com This document is printed on acid free, 10% postconsumer, elemental chlorine free Productolith paper stock. Xantrex GT Series Grid Tie Solar Inverters Electrical Specifications Models GT2.5-NA-DS-240 GT3.0-NA-DS-240, ;' GT3:3-NA-DS-240 GT33-NA-DS 208 GTIA-NA-DS-240 GTS.O-NA-DS-240 Maximum AC power output 2500 W 3000 W 3300 W 3800 W 5000 W AC output voltage (nominal) 240 Vac 240 Vac 240 Vac 208 Vac 240 Vac 240 Vac AC output voltage range 211 - 264 Vac 211.- 264 Vac 1i - • 211 - 264 Vac 183 --'228 Vac 211 - 264 Vac 211 - 264 Vac AC frequency (nominal) 60 Hz i60 Hz •+r 60 Hi 60 Hz 60 Hz AC frequency range 59.3 - 605 Hz 59.3 - 60.5 Hz' 59.3 - 60.5 Hz 59.3 - 60.5 Hz 593 - 60.5 Hz Maximum continuous output current 11.8A .141A 15.6 A. t'fQ .18A'' r 16A 23A Current THD <3% <5% ^i r <3%'_ p <3% <2% Power factor > 0.9 > 0.9 > 0.9 > 0.9 > 0,9 DC input voltage range 195 - 600 Vdc 195 - 600.Vdc •195 - 600 Vdc 195 - 600 Vdc 235 - 600 Vdc Peak power tracking voltage range 195 - 550 Vdc 195 - 550 Vdc 195 - 550 Vdc 195 - 550 Vdc 235 - 550 Vdc Peak inverter efficiency 94.8% 94.6% ,t 953% ' 94.7% 95.7% 96.5% CEC efficiency 94.0% 94.5% 94.5% 94:0% 95.0% 95.5% Night-time power consumption 1 W 1 W 1 W 1 W 1 W Output over -current protection 15A 20A 20A 25 A 20A 30A Mechanical Specifications Operating temperature range -13°Fto+149°F (-25°Cto+65°0 Enclosure type NEMA 3R (outdoor rated) Unit weight 49.0 lbs (22.2 kg) to 58.Olb (25.8 kg) ' ' yt bw' Shipping weight 57.0 Its (25.9 kg) to 65.01b (27.2 kg).; Shipping dimensions (H x W x D) 34.1 x 20.4 x 10.3' (866 x,51 8 x 262 mm) Inverter dimensions (H x W x D) 28.5 x 15.9 x 5.7- (755 x 403 x 146 mm) " Mounting Wall mount (mounting bracket included) Features PV / Utility disconnect Eliminates need for external PV (DC) disconnect Complies with NEC requirements. Cooling Convection cooled, fan not required. Display Backlit, two-line, 16 -character liquid crystal display provides instantaneous power, daily and lifetime energy production, PV array voltage and current utility voltage and frequency, time online 'selling" today, fault messages, and installer customizable screens. Communications One RS 232 and two XanbusTm R145 ports.. , Wiring box PV, utility, ground, and communications connections. The inverter can be separated from the wiring box. Warranty 10 -year standard Part number (negative ground) 864-0108 864-0002 864-0107 . � K,.• t:,1__86470111 , r 864-0119 864.0118 Part number (positive ground) 864-0112 N/A . 864-0114 N/A N/A Positive grounding Positive grounding configurations available for the GT215-A-DS-240, GT33-NA-DS-240, GT3.3-NA-DS-208, & GT3.8-NA-DS-240 inverters as required. Specifications subject to change without noti¢ •J t'1, "jy' l•, O 2007 Xanbu Technology Inc All rights reserved. Xanax Is a reghtered trademark. of Xentres International. Printed In Canada 7 5 2 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" APPLICANT INFORMATION OWNER INFORMATION Last Name h,4 b GV_1 First Name VV Mailing Address 2 �.� City/ 3 State If.57,7 73 Phone.qZ,— 8-tate(— tate Fax E-mail State License Number APPLICANT INFORMATION ARCHITECT/ENGINEER CONTRACTOR Name Address S Address E-mail 3 City Phone 8-tate(— tate E-mail State License Number Phone Phone S Fax Lic. # s- s Class lQ APPLICANT INFORMATION ARCHITECT/ENGINEER Name Stat Address Phone yS ,, / [> LY ?R,, City E-mail State Zip Phone Fax E-mail State License Number APPLICANT INFORMATION Name Address City ` Stat ZS Phone yS ,, / [> LY ?R,, Fax •3 s. E-mail P 4f'l' SIGNATURE X PERMIT NO. BIN #• PROJECT LOCATION AP# Z-130 -0-70 Property Address /C oll City11 l A'7 WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: Scl FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: Zoning Flood Zone SRA I Yes I No Occ. Type Const. 1 t ' /042-130-070 01-0193 MERRIMAN FAMILY TRUST 2799 OAK WAY CHICO . CONTR: LAMBERT MASONRY O CLEARANCE GAS FIREPLACE COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754 rG/a IT NO. (Rev. 12/96) APPLICATION AND PERMIT C ASSESSOR PARCEL NUM886"'0 w 130 _ 020 ZONING BUILDING PERMIT OWNER 1 C. m'1''i n" -h 2u2� JEUEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S tlJNG ADDRESS Oak ,u CONTRACT) NAME t_t 1 c .�rn1 TELEPHONE y3-0.1 CONTRAO 'S MAILING ADDRESS- /� 9 r[.+ 9 3 !/ CONSTRUCTION LENDER Fireplace I A ro LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER UCENSE NO. Fling Fee $ 20.00 Permit Fee ARCHITECT OR ENGINEERS MAILING ADDRESS Pian Checking Fee $ BUILDING ADDRESS Energy Plan Checking Fee $ PERMIT FEE $ 19 LOT NO. SUBDNIS IONS NOME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE _ SF,9 Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE - WORK New ❑ Addition ❑ Remodel ❑ Utilities 0 Installation ❑ Other - Describe Work: 01 ? Lc�_ • �/ ?L2, �/ 1)< u Gas pipinstem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W 920 0 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service oa LEN 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in II force and effect. w �`- License Class- Lic. No. -� OWNER -BUILDER DECLARATION I hereby affir{n under' penalty of perjury that I am exempt from the Contractors License Law for the following` reason: -❑ _,I, as owner of the, property, or my employees with wages as their sole compensation, wiif tto tlT� worif, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service TO 46. NEW CONST. DWEELNJG OCCUP. ELCU OR AODNs. ( a ACC. BUDS. so 3.50 FT. CON9T9 pgµgESlp. MULTI.OUTLETC. @7.50 POWER APPAMTUS 8 SOM OUTLET US Ex, Occup. OLmFTORFIXTURES a20 1.00 FU(ED APPUVS. OR Ex. Occup. O.gESlp, E1 5.00 Temporary Service 23.00 Mobile Home Facilities :,,;0.00 Misc. Wirina 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit Is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith amply wKtho" provisions.' % 1 N \ X �f(! �-' d NI i /I (_ I Signature of Appricant - ❑ Owner ❑'Contractor ❑ Agent An OSHA permit is recWired foo a avalns ovgr 5'0" deep and demolition or construction of structures over 3 stories in �heiFhtl. ��J MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEP $ Mobile Home Installation Fee $ Energy Inspection Fee $ g� /�c S Tv� TOTAL FEE $ 5 5 ' ()D HA2. D FE IMP FLOOD CDF PARCEL PD I HO ISSUE This permit is hereby issued under j of the Butte County Code and/or indicated tibov® for which fees have �� By ! iLCkJ /1 r PERMIT EXPIRES ON f " the applicable provisions Resolutions to do work been paid. Date 36 - (J Oats ReceiptNo. �) r! f WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 P ;IT NO. ---���al (Rev. 12/96) APPLICATION AND -PERM -IT' � ASSESSOR PARCELNUMB 2-0 ZONING BUILDING PERMIT OWNERLEPHONE 99-- 5 SO. FT. OCC. BUILDING VALUATION . OWNER'S MAILING DRESS /Q uAl CONTRACT NAME ry� 2 q TMJ N CONTRAC- C_I DRESS / 9 q5 G -1,3 ,N CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace -6 b • Da Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Flin Fee $ 20.00 Permit Fee $ 3 5, oto ARCHITECT OR ENGINEER'S MAIUNG ADDRESS Pian Checking Fee $ BUILDING ADDRESS / j 1l.//V/ Energy Plan Checking Fee $ �-� PERMIT FEE $ 5 rj . oU LOT NO. SUBDIVISION'S NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF)( Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other Describe Work:0_/-LQ1%Ae_Q_ (,U l( CZO %a V'C_ Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE _ ELECTRICAL PERMIT Fling Fee 20.00 LE Main Service 20 A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in II force and effect. /" /�, License Class Lic. No. e t (/L�r % OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed 0 the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' co pensation provisions of section 3700 of the Labor Code, I shall forthwith, mply tho p on!an . X / � Date ''C/ Signature of Apolca t - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO ta00A 46.00 NEW CONST. DWEWNG OCCUP. OR ADDNS. ( a ACC. erns. sD 3.5¢Fr: NNON•20N& ' muLTI.0 TLET 97.50 POWER APPARATUS 8 SINGLE OUTLET CIA. .00 Ex. Occup. OUTLET ORFD=RES B420 p'.w Ex. Occup. ou7Drs gaDaPR.A. 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirina 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEI: $ Mobile Home Installation Fee $ Energy Inspection Fee $ g� /Lc 3 TYPE ._EO TOTAL FEE $ rj , UD HAZ. o FE IMP j FLOOD CDF PARCEL PO HD ISSUE t This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work -above for which fees have been paid. indicar0V0_W16eJAW By Date / -36 -6 ERMIT EXPIRES ON{ 36� '� Dela Receipt No. W60 9 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT M I COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (530) 538 5 1. PERMIT N+ (Rev. 12/96) APPLICATION AND PERMIT C., ASSES80RPARC TT _ ^, z0+uNo BUILDING PERMIT OwNE�. 1 I�s/N� i©Y11.� �Tt.+ TELVIMNE SO. FT. OCC. BUILDING VALUATION ow NEA COM R'9 NAME V T s=a Oa CONrRAGTO MAU ADDRESS - rd 3 CONSTRUCTION LENDEA LENDER'S MIUUNO ADDRESS Fireplace Total Valuation t+ ARCHITECT OR ENGINEER LICENSE N0. Filing Fee S 20.00 Permit Fee $ ARCWrECT OR ENOWEWS MAJUM ADORESS Plan Checking Fee $ BUILDINOADDRESS _ VVA`-UVJ` Energy Plan Checking Fee $ I $ j PERMIT FEE PLUMBING PERMIT $ Filing Fee 20.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP USEOFSTRUCTURE SF Y Duplex ❑ Mobilehome ❑ Other 1 sP�� Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK + New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: Gas piping system 1 - 5 outlets 15.00 t Building sewer 15.00 i Mobile Home S G W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service AOR LEMS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Profassions Code, and my license is in full fo fe and effect^�! License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that 1 am exempt from the ContrL}ctors License Law for the following reason: I ❑ I, as owner of the property, or my employees with wages as their sale compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensO contractors to construct the project ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I 1 heroby affirm under penalty of perjury one of the following declarations: 16 I have and will maintain a certificate of consent to self -insure for workers' ompensation, as provided for by section 3700 of the Labor Code, for the performanceof the work for which this permit is issued. + have and will maintain workers' compensation Insurance, as requlrod by Section 3700 of the Labor Code, for tha.performance of work for which this permit is issued. My workers' pe tion Insurance carrier and policy number -we: Carrier Policy Number (The above sections need not be completed if the permit Is for work of a valuation of one hundred dollars ($100) or lose.) ❑ 1 certify that in the performance of the work for which this permit Is Issued, I shall not employ any person In any manner so as to become subject to workers' com ensation laws of California, and agree that if 1 should become subject to the w rs' compensation provisions of section 3700 of the Labor Code, I shell f rth ith comply with tho pr vision . X U,1 Sig ntur f Applicant - 0 Owner ❑ Contractor ❑ Agent7Z An OSHA permit is required for excavations over SO' deep and demolition or construction of structures over 3 stories In height. Main Service 200A TO 1000A 48.00 NEW CONST. OWEiIJNO OCCUP. 3 SQFT. OR "DOM. a ACC. eu)s. EW G0115TO NON.REs+O. ' MULTICTn r @7.50 P.0 APmUS oAclR. AL 20 ®+00 Ex. Occup. OLITLET OR FMRES B .50 FaEo APPLNS. oR Ex. Occup. oM. Eslo. Ew 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE _ MECHANICAL PERMIT Fling Fee 20.00 Heating Coolie Hood 8.50 Ventilation PERMIT FES t Mobile Home Installation Fee $ Energy Inspection Fee $ �� �� TOTAL FEES 35. KAZ 0 IMP FLO00 COf PARCEL Po Ho UE This permit is hereby Issued under the applicable provisions of the B tte County Code and/or Resolutions to do work indicat above for which fees have been paid. By ^^/Date PERMIT EXPIRES ON ��o�f' -o to Receipt No. WHITE-D.D.S.-B.D. CANARY - ASSESSOR PINK -INSPECTOR GOLOENROD•APPLICANT x042-130-070 I 01-0166 Merrimanfamilffrust:, , 2799 Oak Way, Chico Cont: Dan Heal 'Gas line for future log lighter I N41 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDINg DIVISION ` 7 County Center Drive • Oroville, California 95965 • Telephone (530) 5 7541 RMIT NO. W�. (Rev.12/96) APPLICATION AND PERMIT (), ASSESSOR PARCEL NyMeFAx.-01 ZONING BUILDING PERMIT OWNEfi,.� 1 . f 1 TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER D/qS��S LJ CONTRACTOR'S NAME f � � — fj�r n TELEPHONE ;�s•��j--� 1�� t! CONTRACTOR MAILING ADDRESS ^� r CONSTRUCTION LENDER Fireplace LENDER'S MAIUNG ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS /'� •---I !; • r , �J a, Energy Plan Checking Fee $ $ • !�` W PERMIT FEE S LOT NO. SUBDNIS IONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF JY Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: ' Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W 920.00 PERMIT FEE S y fj • {7! rJ ELECTRICAL PERMIT Filing Fee 20.00 Main Service CoA oA "ss 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full fore and effect. yq ��•i, License Class �' Lic. No. , ` �, - OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: C I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for th9 performance of work for which this permit is issued. My workers'penaation insurance carrier and policy number are: Carrier , Y- '_';.r r - t Policy Number A/ fe& a - e., `-s z_ i� (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the WQfkers' compensation provisions of section 3700 of the Labor Code, I shall ii forthwith comply with tho pr is7,; X `•- Date , �� _ Sig6atur'e-6f Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Main Service sooA TO 46.00so CCU000A NEW CONST. DWEILMN3 OCCUP. SO OR ADDNS. ( a ACC. BLD S. 3.50FT. EW T. NON•RESID. MULTI.OUTLET 97.50 POWER APPARATUS IS CLE OUTLET CIR. 20 @ 1.00 Ex. Occu OUTLET ORFUTURES BAL @ .w Ex. Occup. o,n,EE°rs PP M.) Ew 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE i MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ �' • .�� CQNST. TYPE t1 TOTAL FEE $ HA2 D IMP - FLOOD CDF PARCEL PO HD ISgUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicat above for which fees have been paid. B j' ; y C �- . -• Date PERMIT EXPIRES ON )�q 0 Delo Receipt No. 'moi 0 V / , � 1� __ __ WHITE-D.D.S.-B.O. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 I 7 County Center Drive • Oroville, CA • (530) 538-7541 3vOWNCORRECTION NOTICE LIL /30- OWNER ER PERMIT NO.. t• A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, .h . please contact this office immediately. 1517VC4-- '��--- . l sd'� - / `'✓ Sp" � � c moi, � ../ r+• 7 4 S, h " I YF. _ Date Z� / Inspector REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street * Chico, CA * (530) 891-2751 7 County Center Drive - Oroville, CA * (530) 538-7541 Fl. CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office -immediately. ri Al Date Inspector REV 10/42 Fal -- ". ------ -ter_-"--•. ••--"�----'-r '�.-�_._._.1,!'•..�...,citi...-..a.�...-....-Y,y+a�iiFtW...�c, r.J�--w' -" K`rV+"--`+'— — . - —" COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDIN DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 5 -7541' RMIT NO. (Rev. 12/96) APPLICATION AND PERM(T (� ASSESSOR PARCEM7 36 ZONING BUILDING/PERMIT OWNE . f TELEPHONE SO. FT. OCC. BUILDING VALUATION .OWNER S CONI R'S NAMEV. ain 3(1 5-c i a CONTRACTOR MAIU :ADDRESS ^ 'J( oicLah� rd CONSTRUCTION UEND Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Fee $ 20.00 —Filing Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS _ Energy Plan Checking Fee $ PERMIT FEE $ LAT NO. SUBDMSIOWS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF X Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water Water piping 15.00 gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ U5lities ❑ Installation ❑ Other ❑ Describe Work: Gas piping stem 1 - 5 outlets 15.00 !j, (j Building sewer 15.00 Mobile Home ISI GI W @20.00 PERMIT FEE $ 35 ELECTRICAL PERMIT Fling Fee 20.00 Main Service zoDA OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full for a and effect.a License Class C Lic. No. OWNER -BUILDER DECLARATIONEX. I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO L000A 46.00 NEW CONST. DWELLING OCCUP. OR SUDS .I ( & A . 3.50so FT.. cONS. NDN REBONST ID. @7.50 POWER APPARATUS a SINGLE otrrt� cIR. OCCu OUTLET OR FIXTURES .00 BAL @ I.50 Ex. Occup. GimEls RES 6.) E 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION 1 heroby affirm under penalty of perjury one of the following declarations: El I have and will maintain a certificate of consent to self -insure for workers' .,compensation, as provided for by section 3700 of the Labor Code, for the of the work for which this permit is issued. have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' pe ation insurance carrier and policy number are: Carrier _, - �,, Policy Number (The above sections need not be completed 0 the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' an bon laws of California, and agree that 9 1 should become subject to the rs' compensation provisions of section 3700 of the Labor Code, I shall ith comply with tho a provision 0—of X CrC9 V Sig Applicant - ❑Owner ❑ Contractor ❑ Agent Aatur An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt $ Mobile Home Installation Fee $ Energy Inspection Fee $ �Dc TYPE TOTAL FEE $ LIU HAz. D IMP FLOOD CDF PARCEL PD HD UE This permit is hereby issued under the applicable provisions the B tte County Code and/or Resolutions to do work indicat above for which fees have been paid. By &MIGI&O I nn/Date PERMIT EXPIRES ON Date ReceiptNo. y WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT ,jsI I TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance E.H. USE ONLY Plot Plan Anodwd Yes y, a Fl" Plan Attached %s' Sore to B.D. 9-7 /1%E",k,e/H/d V 2-799 Lick y4y, X92- - /36 - 076 Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for . Other is o,�rrol dd/ Hold final for: Final clearance O.K. for: NOTE: Pool a,;2y ✓asciorr ax d 71- Enviro entd Health Specialist Date 8/92 / � y , \ \ � \ . � . � � � \ � j. � � � A 9 � f, 2 3 . ® � m m � , � ` � � - � , . � � : m � � , ','E �� �l[UA L __- _-_- - -' -_ ------ -- ---. 042-130-070 PEDMIT#90-1591 " - | MEDRIMAJV, Charles / 2799 Oak Way, Chico Cont; Adonis Pools & Spas ' New Pri Swimmio8,Pool ' ` [ � | ` r , � JOB FINALED (Date) �/// 1�?6 Signature �� V=OK O = Not OK Not oAeady Not RMOBILE HOMES ' Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements - Setbacks - Easements 2. Footings; Soils-Size-DepthSpacing-Connectors-Steel 2. Soils; Special MH Support Sketch 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer, Location -Test -Fall -C/O -Concrete 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 4. Water, Location -Test -Easement Needed (Sketch) 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 5. Electricity; Location-Clearances-Gmd-/ /Amp -Concrete 6. Carports; Windows -Doors 6. Gas; Location -Test -Wrap; / tUft. / /Nat. or/ /'L"ft./ /LPG 7. Electric 7. Well Clearance & Disconnect 8. Frmg.; Sils-AnchorsStuds-Rftrs-Trusses 8. Utility Clearance 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements- Setbacks Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line POOLS Plans OK except #'s 3. Gas; MH Test -Demand -Valve -Connector etbacks-Easements 4. Electricity; MH Test -Crossovers -Breakers -Clearances is; Compaction -Structure Stability 5. Drain; MH Test -Fall -Flex Connector Structure; Steel -Connections -Thickness Dead Men -Linin 6. Water; MH Test -Regulator -Connector 4 I rR' eceptacles and Lighting, Distance-GFI Pool Lighting; 15 Volts-GFI 7. Water and Sewer Connected -C/O to Grade -HD Approval I .; Enclosures; Conduit Entries -Terminals -Listed 8. Gas and Electricity Tagged V-1116—&-nding; Metal w/6 -Circulating Equip. -Heater 9. Tie Downs -Type -Installation Cert. . Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 10. Exits; Insp.-Sketch -G. Health Q2ga=ent Approval 11. Cert of Occupancy 1 mb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS .Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils-Size-DepthSpacing-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS Plans OK except #'s etbacks-Easements is; Compaction -Structure Stability Structure; Steel -Connections -Thickness Dead Men -Linin 4 I rR' eceptacles and Lighting, Distance-GFI Pool Lighting; 15 Volts-GFI I .; Enclosures; Conduit Entries -Terminals -Listed V-1116—&-nding; Metal w/6 -Circulating Equip. -Heater . Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit -G. Health Q2ga=ent Approval 1 mb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 i J=OK O=Not OK _ Not Applicable Not Ready RESIDENTIAL (Single = Date UNDERFLOOR (Plans) OK except N's 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; 'Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth & Duplex) Date FRAMING (Continued) 45. -Hangers -Post Caps -Anchors -Connectors 46 Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth ------ 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel- Bloc kouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit),OK except 4's 16. Water Htr.: Vent -Access -Combustion Air -Baffle --------------------------------------------------- ------ - --- ----- 17. Water Pipe; Test & Anchor -Nail Protection --------------------- 18. D.W.V ; Test -Fittings & Anchor -Nail Protection --------------------------------------------------- --- 19. Shower Pan; Test. First Floor -Tub Access ------- -------------------------- ----------------------------- 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe: Size & Anchors ---------------------------------------------------------------------------- DateCard B-1 Date Card B-1 ------------------------ ----------------------- -------------- ------ Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except n's '22. Fixture &•Transformer Clearance -Ins. Protection --------------------------------------------------------------- 23. Elec. Receptacles Spacing -Lights & Switches at Doors ------------------------------------------------------------ -- 24. Size Boxes & No. of Conductors -Stapled ---------------------------- 25. ---------------------- 25. Romex Installed Close to Edge of Studs & C.J. -------------- ------ --- ----------`-------------------------------------- 26. Equip. Ground made up wrMech. Fastners-Bond Gas & Water --------- --- -------------------- - 27. 2 Appliance Circuts in Kitchen & Conductor Size,GFI --------------------------------------------- --- --- -- 28. Subfeed Wire Size ga. Cu or AI-A.C. Wire Size ga. Cu or At -------------------------- 29. Range Circ ga. Cu or AI -Oven Circ. ga. Cu or Al. Insulated Neutral C1Yes ❑ No - ------------------------ ------ ---..... .. 30. Service -Riser Conductors & Ground -Main Disconnect - -------------------- -- ------------ ---.... .. 31. Equip. Clearances Panels-Motors-Mech. Equip. ------.._I----------------- ------- ------- --- .. 32. Clothes Closet Light -Shower Light -Spa Light -------------------------- ------------------- ....... . 33. Smoke Detector ------------------------------- - I— ------------------ --- --- -I ..... ........ .. Date Card B-1 Date Card B-1 - -----------. ...... _............. .. ....I----------- _. ... ... ... . Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except a's 34. A.C. Ducts Insulation & Support ---------------------...----------- .. . . . ......... .... ... .. .. .. 35. Vent Fan: Exhaust above insulation ---------- ----- _._ .. _....__...... .. 36. Condensate Drain & Overflow: Sze & Grade " 37 Furnance-Vent: Access -Comb. ....Air -Return Air Vent -115 outlet - - - ------ ----- - 38 Attic Access & Platform if Furnance in Attic ------ ------ --- --- --- -. .. Date Card B-1 Date Card B-1 Date Card B-1 Date Card 8-1 Date FRAMING (Plans) OK except a's 39 S Is. Proper Material & Anchors ....... ... __. ... ... 40 Walls Studs -Nailing. Spacing & Bracing -Plates -Sound ...... ....... ... ... .. ... _--........ I... ...... . 41. Bearing Walls over Girders & Floor Nailing 42 Draft Stop in Walls (rat proof) ------ -- ----- --- ... _._ .... ... .... 43. Fire Stops: Furred Ceilings -Stairs -Chases -Tub -----------. .... - 44. Headers & Beam -Size & Bearing 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50 Garage Fire Protection Framing _ 51. Property Line Firewall & Openings _ 52. Ext. Doors -One 3=Check Garage -3rd Story, 2 Exits ______ 53. _Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. Sidiho-Nailina Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access ---------------- 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls: Nailin Bolls 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows ------------------------------------------------ - Date Card -B-1 Date Card B-1 - ----------- ----- ----------------------- Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except a's 61. Ext. -Steps -Door & Sidelight Protection -Landings 62. Smoke Detector ----- ------- ------------------------------ - - 63. Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor -Ducts -Meth. Protection ------------------------------------ 64. Bedroom Exiting 65 G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel: Breaker Sizes & Labels ------------------------------------------ 67. Stairs & Rails --- - - - ----------------------------------- 68. Fireplace or Stove: Clearances -Hearth . _-- .._..------------------------------- 69 Elec. Outlets at Wood Panel: Int. & Ext. . - - - --- ------------------ -------- --- ---------- 70. Kit.Fixt. & Appliance: Grnd.-Air Gap -Cooking Clearance ----------------------- ----------- -- 71. Elec. Outlets & Receptacles at Kit. Counter . ... ... ... ...------------------------------------- 72. Garage Fire Door: Swing -Landing -Closer ... ... .. . ...... . ... - - - --------------- - 73. A.C. Duct in Garage -Damper ..................... --------------------- --- 74. Wtr. Htr.: Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above Floor-Mech. Protection ..... - ------------------------------- ---- 75. Plb.. Elec. & Mech. Equip. Listed for Location ...... .............--------------------------------------- - 76. Elec. Receptacles in Garage: (G.F.I.)-Romex Protection --- ------- - ---- ---------------------------- 7, Insulation -Foam -Looked in Attic ❑ Yes ------ ------------------------------------------- 78. Guard Rails & Deck Construction -Post Caps ---..---------...----------------------------------- -- 79 Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes - - - ------------------------------------- 80 Following instld.,. Drive ❑ Yes ❑ No: Walks ❑ Yes ❑ No: Planters ❑ Yes ❑ No . ... .-------------- ------------------------------ 81. Stucco: Brown -Finish ... ... ... ... -- - - ------------------- C isco ------------------- 82 A Unit: Dnnect. Electrical, Plumbing .. . -- --------------------------- - - - - - - - - --- - - - ------------------ --------- 83. Vents Above Roof: Plbg.-Appliance-Fireplace.-Clearance to Openings ....... ... - ----------------------------- 84 --- ------------------------84 Water Well: Disconnect. Electrical, Plumbing -------------------------- ----- 85 Exterior Elec. Trim. G.F I. Receptacle -Underground . . ---- ------ ------------------------------- 66 Ventilation Throughout House .. . - ------ ------------------ ------------------- 87 Glass Protection - - ---------------------- 88. Corrections from Previous Inspections --- .-. ----------- ------------------------- 89 Gas Test -Meters Tagged: Gas -Electric --- - -- --------------------------------------------- ------------------------------------ 90 Water & Sewer Connected-CrO to Grade -HD Approval - -- ------------------------- 91 Energy Compliance Certificate -Other Certificates - - ---- - -- --------------------- Date Card B-1Date Card B-1 . . ..... . .... ._-------------------- ------------- Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: __,COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 .County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO, ql APPLICATION AND PERMIT L I SESSOR PARCEL NUMBER (+2-130-070 ZONING BUILDING PERMIT OWNER CHARLES MERRIMAN TELEPHONE 899-7454 SO. FT. OCC. BUILDING VALUATION 25,000 OWNERS MAKING ADDRESS 2799 OAK WAY CONTRACTOR'S NAME ADONIS POOLS & SPAS TEIEPHONE 891-1197 CONTRACTORS MAILING ADDRESS 12 PHEASANT RUN CT Fireplace CONSTRUCTION LENDER UN -OWN Total Valuation Is Filing Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 252.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 23.00 Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS - 2799 OAK WAY, TTICO PERMITFEE $ 295.00 PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 LOT NO. SUBDNISIONSNAME PARCEL MAP Solar or heat pump water heater 23.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other POOL SPECIFY Water piping 15.00 5.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: MASTER 94-504 Mobile Home S I GI W @20.00 PERMITFEE g 35.00 Contractor ELECTRICAL PERMIT Filina Fee 20:00 Main Service600v OR LESS ( 200A OR LESS ) 23.00 Main Service ( 200A TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is full r and effect. ` % License Class Lic. No. (D vJ OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages astheir sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this son NEW CONST. DWELLING OCCUR 50. OR ( 8 ACC. BLDS. ) 3.5¢ FT. CNS. NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 S / POWER APPARATUS ) 8 SINGLE OUTLET UCIR Ex. Occup. (OUTLET OR FURORES) BA0 @ 1.00 Ex. Occup. ( OUITLETS(RESD.OEA, ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 130.00 PERMITFEE $ 50,00 Contractor WORKERS' COMPENSATION DECLARATION ker_Zyaffirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance cTarrier and policy number are: Carrier ��'-(�) OD MECHANICAL PERMIT FilingFee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE $ Contractor / Policy Number (The above sections nee not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ an person in manner so as to become subject to workers' P Y Y P any mJ compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall fo hwith comply with those provisions. Q X _ Date r I� I�Q-- Signature of Applic t - ❑ Owner ❑ Contracto�A6eni An OSHA permit is required for excavations over 5'0" and demolition or construction height. of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee Is OCC CONST. TYPE TOTAL FEE $ 80'QO HAZ. I D. FEES I IMP I FLOOD CDF PARC0. PD I MDQrISSU50 This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indic d above r which fees have been paid. BY Date PERMITEXPIRESON 7/7- f/ y 7 I (Date) Receipt No. 10 ( / b WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT 0 ;COUPITYOF BUTTE - DEPARTIIENTOD,XyEWOPMENTSERVICES - BUILDING DIVISION 7COUNTY CENTER DRIVE;:,OROVILLE, CALIFORNIA 95965 -TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER C t414A WJ l "ERR 1 /n A irj A. P. No. / 13 -70 Proposed Building Use /Uc�' p''� �5P"�L .Building Inspector tDate ig GJ6 7-1 At time of > ermit application, I was advised the following data must be submitted prior to permit processing and/or issuance: 1. I DATE RECEIVED BY All items have been :submitted.... ` ..................................... 2. Plot plans, 3/4 sets, signed -by preparer of,plans. z' ....................... ° 3. Complete plans, 3/4 sets',`signed by preparer of plans. ................ .. . 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material.Form............................................. 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent,for Non-Heated,and A/C Buildings . ..................... . 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . - 9. Mobilehome data and manufacturer's installation instructions, 2 sets. ........... _r 10. Fees of $........................................ ` 11. Impact fees as shown on attached schedule . ............................. . 12. California Department of Forestry plan approval/fees. ►" 13. Flood elevation letter (10.0 year flood) by California Engineer . ................. . 14. Sanitation and plot plan approval Health;Qepartment. ............ 15. City of Chico plumbing permit' .................... �................. . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: . ......... 18. Contact Land Development.about (A), Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval required prior to occupancy). ...- 20. Pre Inspection requ. Pre -inspection for required. .. to Building Inspector (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner . ........... ' 24. Recorded copy of Agricultural Acknowledgement Statement . ................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ..................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed -. and (B) Parcel meets zoning area and frontage requirements. 31. Existing violations/expired permits. 32. Plan check list . ....................................................... . 33. 34. W_her ou issue the permit, process as follows: Mail to owner. Mail to contractor. �� Telephone and hold for pickup at office. Deliver with inspector. Other Parcel Creation "� Acreage Applicant4 Date )6 Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date_ -- Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index,permit for above items No. 2. Add itional,ite_ms required: Contractor,-iiesigne�owner, was advised of above required data by_ phone -mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Plans checked by Date Plans approved by Date oZ G Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works L Cf) 'N APPROVED &mq count•y Date Environmental Health si MAY 2 2 1995 Chloo, Califomia LAND DEVELOPMENT - BUILDING PERMIT CLEARANCE Building Permit No. 'qNDE/-S oma' , W S Y/V L/ OWNERNAME %rl lit LL d NUMBER: D T 1-30 -0-70 1 PRINT LAST NAME FIRST/ COUNTY ZONING* DESIGNATION: A S FLOOD ZONE: FLOOD MAP: -Zoo C3 APPROVED: CONDITIONALLY APPROVED: PARCEL CREATION BY DEEDS RESOLVE PROBLEMS PRIOR TO APPROVAL: In/A-S a 4z- - 1 3o - of 9 SPI -17 rb Y C)3-99 3-t& e, O / LAG 0 DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO LEGAL ACCESS REQUIRED: YES NO COMPLIES WITH COUNTY STANDARDS---FOR-DEED CREATION: YES NO O&C3 Nb'r FKOAf r COMMENTS/CONDITIONS: -Pf2,0 V 1 0C �C2.Eg Tl n/�i %J��D Llai- 99 34 % 3 -7 ) DATE OF RECORDING PARCEL CREATION BY MAP LOT BOOK PAGE COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DIVISION UNLESS OTHERWISE NO TED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a building setback from right-of-way/centerline of 3. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. 4. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. 5. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ 6. Maintain a 100 ft. leachfield setback from all existing wells. . 7. Maintain a ft. leachfield setback from 8. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. 9. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to the Planning Division. 10. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. 11. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. 12 9LL CHECK APPROPRIATE REQUIREMENTS YES OR NO OR CONDITION NUMBER. LD 12194 - C:1WP511F0RMS.K\BLDGPERM.CLR W jo" Sfc�/iv2y L)t R SIDENTIAL 042130-070 PERMIT#95-1044 --- 'MERRIMAN, Chuck & Linda 2799 Oak Way, Chico Cont; Gard Anderson New Single Family e;� loo OFFICE COPY Address 29g 004/- GAS Meter 4eter By ELECTRIC Date/ Meter By Date�� OFFICE COPY Address lz?qi Odk 0j, 7-84io�?— GAS Meter By ELECTRIC Meter By'Datews>-q 5;r - JOB FINALED (Date) Signature F J=OK O= Not OW =Not Applicable MOBILE HOMES } ' =Not Ready ) Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks- asements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /"L"ft. f / /"Nat. or/ /"L"ft./ /"LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector ti 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J I MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing _ 11. Ext.; Steps -Doors -Landings t Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s s.W 1. Setbacks -Easements ..} 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining i 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK O = Not OK = Not Applicable = Not Ready I RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except ff's VTfWZ_r -iyi - - Easements -Flood -SI Main: Soils-Elec. Grnd.-/ /" $!Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg. orches & Decks; Soils -Steel-/ /Ftg. Depth temwalls, Main; Steel -Bloc kouts-Wrapped emwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped iB-PieL%,FPPeoIace Fta.-Steel W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test s Pipe; Size -Anchors - yard gas piping: size -test Ater Pipe; Test -Anchor -Regulator -Service Test _ / 12. Elecyie; Underqround ri11-Pienu Ducts; Clearance -Material -Support -Ins. 1 d Sills -Anchor Bolts -Joists -Vents -Cripples 1 cces Ventilation e -4i 1 sulation Date WlrU Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMB IN Permit) •OK except N's 1 ater H r.: Vent -Access -Combustion Air -Baffle -------------------- ------------------------------ - 1 ater Pipe; Test & Anchor -Nail Protection __ ----------------- 18 D.W.V.; Test -Fittings & Anchor -Nail Protection - -- --- ----------------- — ----------------- —19. Shower Pan: Test. First Floor -Tub Access -- — _--2T-Test Tub & Shower. Second Floor -Tub Access -- V -G- as-Pipe_Size & Anchors Date (7��Card B-1 Date Card B-1 -- ----------------------------- Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except ft's �?•r Fixture & Transformer Clearance -Ins. Protection -- ----- -- Elec. eceptacles Spacing -Lights & Switches at Doors ---- -- -- - ---- ------------------------------------------- Size Boxes & No. of Conductors -Stapled -------------------- - - - o -x Installed Close to Edge of Studs & C.J. -------------- ---- --- - - ------ -- ------------------------------------------- �0 � Equi round made up w/Meth. Fastners-Bon &Wad r� --------- --- ---- ------------------------------------------ Applian_ce Circuts in Kitchen & Conductor Size/GFI L& -S I ire Size i ( a Cu or AI- .C. Wire Size r ga. --- ------ ----- - -------------- - -Cu o AI-- -- ----------------------- - ------ �nge Circ. ///,, ga. Cu or A Oven Circ. / ga. Cu or AI. Insulated Ne7fral Yes_ -------/ear uce-Riser Conductors & Ground -Main Disconnect ------------------------------------------------------ E Clearances Panels-Motors-Mech. Equip - -- --------------------------------------------- - - -- Clo Closet Light -Shower Light -Spa Light ---------- moke Detector ---------------- ---------------- ---- ------------- - - - ----------------------------- ---- -- -- --=- ----------- --- ----- - - ---- -- - - Date j(,-(8-4)Card B-1 Date Card B_1 -----F----- --------------- -------- -------------- - - Date Card B-1 Date Card B -t Date MECHAJNIGAL (Permit) OK except n's A.0Ducts Insulation & Support ------------------------------------------------------------- '3�Dent .Exhaust above insulation --------------- C3t3� o n. ate Drain & Overflow: Size & Grade ---- ---- ---- --- ---------------------------- 3 urnance-Vent: Access -Comb Air -Return Air Vent -1 15 outlet -- - -- -- -- - - - - -- -- --- - 38. Attic Access & Platform if Furnance in Attic Date( ----- - -��_ ,� C - - ardrd-B_1 -----Date------------------- Card -----B----1 ----------- - -- - --- -- ----------------- --------------------------- Date Card B-1 Date Card B-1 Date FRAM!(Plans) OK except ft's Sits. Proper Material & Anchors -------------------------------------------------- 4� Nailing Spacing & Bracing -Plates -Sound -- --------------------------------------- ng Walls over Girders & Floor Nailing ---------------- --------------------------------------- ------------------ ------ Draft Stop in Walls (rat proof) _ 4 Fire ops Furred Ceilings -Stairs -Chases -Tub JA-<eaders & Beam -Size & Bearing Date FRAMING (Continued) . 4(vWSngers-Post Caps -Anchors -Connectors Ing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. -- - 47• Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles --- 4�6 r -Windows or Exiting Doors -Sill Hgt. & Dimensions arage Fire Protection Framing �3T.-Property Line Firewall & Openings ------------------ xt. Doors -One 3' -Check Garage -3rd Story, 2 Exits ----- X57 St -_ Width -Headroom-Rise-Run-Landing-Fire Protection plywood on Roof Overhang -Attic Vents -Rafter Outriggers g Nailing Veneer (y� 5 tucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows -Date //40 Card B-1 Date Card B-1 Date Card 13-1 Date Card B-1 Date FINAL - except ft's -LandingstDo61. ection 2 oke Detector 6 nate: Vents -Clearance -Comb. Air - connector -In. rage; Above Floor -Ducts -Meth. Protection Bedroom Exiting -- F.I. & Bath Fixtures & Tu ccess 66. • c. Tri�S pa _Breaker Sizes els ---------- 67. Stairs A" :��------- u c_e or Stove: Cleasy-rtes ------ 69--EVC-Outlets at Wood Pa, 117ligy Ext. 7.P1"Kit.Fixt &Appliance; Grp.- � ap-Cookinarance 7V-- Outlets & Recepta Sat Kit unter ------- - --- ---- ----- 7� Ga e Fire or: ng -La mg-CI� ------- - - - --------- 7 A.C. Duct in Garage -Damper 7 tr. Htr_Vents-Clearance-Comb Air -Connector- . . In arage: Above Floor -Meth. Protection ( 7Elec. & Mech. Equip. Listed for Loc 'on --------------------- - --- ---- 76. yEI�e''Receptacles in Garage; (G.F.. - omex Protection i Insulation -Foam -Looked in Attic _ --------------- 74—,Guard Rails & Deck Construction- aps ';i dn. Vents & Crawl Hole Door-Drainag9e, & �Woo� .-Earth Clear nce Looked under Flo _ - ------- - - - - Y - v -. --- No: Walks ❑ Yes Q— - PI ters Yes ---------------- ---_Ye - ------ ------------------------ -- Stucy-p.: Brown -Finish y - -- A"C Unit Disconnect Elect ' Plumbing 4eVents Above Roof; Plbg.-Appliance-F' ace. -Clearance to O Ings -- ater Well; Disconne umbing ` er.or Elec. Trim I. Receptacle -Underground en anon Throughout House ------------ ' .Glass Protection----------�-------------- ---- ----------------- tions from Previous Inspections_ -- -�' .( Gas Test --Meters Tagged; Gas_Ele_ctri — 90. Water Sewer Connected -C/__ Grade -HD Approval 9l!ergy -nCompliance Certificate -Other Certificates Date- % Z9 _-I-.-----Card B-1 Date Card B-1 - --- —----------------------- Date , ff . Card -8- 1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: I 2277 East Fifteenth Street PIPE NIPPLES: NX EDMUND A. Ali~ M OMPANY, Inc. STEEL, BRASS, PLASTIC, STAINLESS AND ALUMINUM PIPE NIPPLES (213)625-2723 P R O D U C T L I N E Los Angeles, California 90021 7 Bl Standard Black CW Standard Galvanized CW Extra Heavy Black CW Extra Heavy Galvanized CW Seamless Pipe and Pressure Tube Nipples - Schedule 40, 80, 160 and Double Extra Heavy (Galvanized Seamless.nipples available upon request) -;>Right & Left Combination - Black`& Galvanized Butt Nipples (all materials) Brass (Schedule •.40 & 80,) Aluminum (Schedule .40-.& 80) Stainless Steel'(all,,types, schedules & grades) P.V.C. Plastic (;Schedule 40 & 80) Mo�ided Poly Cut -Off .Risers Marlex 900 Elbows Tank .& Longscrew Nipples Victualic Type Grooved Adaptors Electrical Conduit - Rigid Conduit and Aluminum and Running Thread Assortments and 1/2" - 3/4" = 1" -Gray Trays Cut -to -Length Pipe Special Fabrication P.T.F.E. Thread Seal Tape COUPLINGS: Standard Merchant.Steel - Black & Galvanized Standard Merchant Steel Half -Couplings Standard Merchant Right & Left A.P.I. Recessed Line Pipe Couplings - Black & Galvanized A.A.R. Non -Recessed Extra Heavy Non -Recessed Half -Couplings Rigid Galvanized Conduit Couplings FORGED STEEL: (Manufactured by ANVIL Products, Inc.) Forged Steel Fittings - 2000#, 3000# & 6000# Anvilets Valves - Gate, Globe, Check, Stop Check, Swing Check Threaded, Socket Weld & Flanged �Merchant Items Steel Fittings for Plastic Pipe "IF IT'S A PIPE NIPPLE ...... WE HAVE IT" INSULATION CERTIFICATE GARD ANDERSON IC -1 2799 OAK WAY CHICO Number and Street City BUTTE County-___ _ _ Subdivision, of Number Description of Installation ROOF Material Thickness (inches) 2. CEILING Batt or Blanket Type Thickness (inches) _ Loose Fill Type INSUL-SAFE III FIBERGLASS 12 Brand Name Thermal Resistance (R -Value) Brand Name CERTAINTEED Thermal Resistance (R -Value) 38 Brand Name CERTAINTEED Contractor/s min installed weight/ft' Ib Minimum thickness inches Manufacturer's installed weight per square foot to achieve Thermal Resistance (R -Value) 3. EXTERIOR WALL Frame Type WOOD A. Cavity Insulation Material FIBERGLASS BATTS Thickness (inches) -6 8 . Exterior Foam Sheathing Material Thickness (inches) Brand Name CERTAINTEED Thermal Resistance (R -Value) 19 Brand Name Thermal Resistance .(R -Value) 4. RAISED FLOOR Material FIBERGLASS BATTS Brand Name CERTAINTEED Thickness (inches) 6i: Thermal Resistance (R -Value) 19 5. SLAB FLOOR/PERIMETER Material Thickness (inches) Perimeter Insulation Depth (inches) 6. FOUNDATION WALL Brand Name Thermal Resistance (R -Value) Material Brand Name Thickness (inches) Thermal Resistance (R -Value) Declaration I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficiency Standards for residential buildings (Title 24, Part 6, California Code of Regulations) as indicated on the Certificate of Compliance, where applicable. 2,34 ���. ! tef- #s —nature, Oate 10/23/95 tel#s — Signature, Date 9 �) - 1120-f- tem—Signature, Date Revised July 1995 SHASTA INSULATION Installing u contractor o.Name) General Contractor lCo. Name) OR Owner Installing Subcontractor(Co. ame General Contractor (Co. Name) OR Owner n Subcontractor-( Co. Name Genera Contractor (Co. Name) OR Owner s I WOOL APAltv-ro Certificate of Conformance' Certificate K? 20863 THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural wood products -identified below and marked with a collective mark of American Wood Systems (AWS) were man. ufactured in accordance .with the specifications Indicated below. X)0 ANSI Standard A190.1-1983, for Structural Glued Laminated Timber NER 261 IT IS HEREBY CERTIFIED that the structural glued laminated timber production of the above-named manufacturer which carries a collective mark of American Wood Systems (AWS) Is subject to regular audit by American Wood Systems, such audit consisting of the Inspection with reasonabi frequency of the manufacturing process, with adequate sampling to verify the quality of glulam conelfuction and the adequacy of glue bond. wN ��.��PpOAgr `r�� 1 vyi by SEAL . YASH1it6 11 t� Thomas G. Williamson Executive Vice President AMERICAN WOOD SYSTEMS — A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION WESTERN BUYERS INC. Mga/4 itl&y _ CrARD Aiypogsa Job Name ELK GROVE, CALIFORNIA Job Location . WB-22789��. 09-0I643 Mipr's Order No. Customer's Order No. Date Yt " A YF k14 se x� A0 , QUALITY CONTROL SUPERVISOR Signature—Title BOISE CASCADE, CORP. Address P. 0. BOX 50 Date. Company BOISE, ID 83128 IT IS HEREBY CERTIFIED that the structural glued laminated timber production of the above-named manufacturer which carries a collective mark of American Wood Systems (AWS) Is subject to regular audit by American Wood Systems, such audit consisting of the Inspection with reasonabi frequency of the manufacturing process, with adequate sampling to verify the quality of glulam conelfuction and the adequacy of glue bond. wN ��.��PpOAgr `r�� 1 vyi by SEAL . YASH1it6 11 t� Thomas G. Williamson Executive Vice President AMERICAN WOOD SYSTEMS — A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 53.8-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE 14 11i �S-/off OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please c9ntact this office immediately. IT W6440 0 v Aj 41212kv 0h L14erE Ccs L«(, A Loc 10.4 a t9c.woJCJVYv� `- (L alk�" 61 Qlyrz _ (=IJ � &- t1(d� %� Date inspector �' �J� Inspector REV 10/92 .. COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538=7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE q-�)7- 10gq OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, AIM contact this office immediately. OL&I)L' -#s cm --�9 V t/ w,.�r_rif.�►' I1 _:, .` � ire a V g '111,11®RIAL116161M W17- 015 a •, .l Date �, Inspector REV 10/92—> COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891"2751 7 County Center Drive, Oroville, CA - (9 16) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. 1-- -- Date �0'/y�) Inspector �1�j k l/ REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER 1►[0a A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. �f) i0t 2 rt S Cd/A'S/7"' A-1- n l-A-T�- C -It" l , Date I I' I J� c Inspector REV 10/92 COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES- BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT NO. APPLICAftNAND PERMIT 95-1D ASSESSOR PARCEL NUMBER 049-130-070 ZONING AS BUILDING PERMIT OWNER CHUCK & LINDA MERRIMAN TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 2763 OAK WAY, CHIC0 95926 3811 R 205,794 1318 M 23,724 CONTRACTOR'S -NAME GARD ANDERSON TELEPHONE 342-6138 497 C 6,461 CONTRACTORS MAILING ADDRESS 9737 OAK WAY, CHTCQ 05996 Fireplace 1 3 4,500 CONSTRUCTION LENDER UNXNOWN Total Valuation Is 240,479 Fling Fee $ 20,00 LENDER'S MAIUNG ADDRESS Permit Fee $ 1,133.0( ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 736.4 Energy Plan Checking Fee $ 23 ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS PERMIT FEE $ 1,912.45 PLUMBING PERMIT Fling Fee 20.00 Each Trap 181 7.00 126.00 LAT NO. SUBDIVISIONS NAME PARCEL MAP Solar or heat pump water heater 23.00 USEOFSTRUCTURE SFX3 Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 15.00 Each gas water heater or vent 15.00 30,00 Gas piping system 1 - 5 outlets 15.00 15.00 Building sewer 15.00 15.00 TYPE OF WORK New IX Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 4 BDRM Mobile Home ISI GI W1 @20.00 PERMITFEE $ 221,00 Contractor ELECTRICAL PERMIT Filina Fee 20:00 Main Service OOOV OR LESS ( zooA oR LESS ) 23.00 Main Service ( 200A TO 1000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in II force and effect. License Class 2 Lic. No. d �� OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR ADDNS. ( .-& _ACC. BLDS. ) SD. 3 . 52 Fr. 179.5 NEW CONST. MULTI-OUTIET NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( OWER APPARATUS ) 8 PSINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 Q 1.00 B`'L .50 EX. Occup. ( OUTLETS P DJ EA 1 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 222.5 Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. O 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 Heating 2 15.00 30.00 Cooling 2 25.00 50.00 Hood 6.50 6.50 Ventilation 4.501 18.00 PERMITFEE $ 124.50 Contractor Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. & / �/ ' X �(.t __ ___ Date _ � Signature of Applicant - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over '0" deep and demolition or construction of structures over 3 stories ' height.. Mobile Home Installation Fee Is Energy Inspection Fee I $ 46.00 OCC CONST. TYPE TOTAL F $ 2 5 .45 HAZ. D. FEES IMP FL D C PARCEL HD SUE This permit is hereby issued under of the Butte County Code or indicate v for which f s avb By PERMITEXPIRESON '76 I the applicable provisions Resolutions to been p -d. Dat 7 9N D..) do work O T RipcelptN . b39 ys �`��7 y (O [, S� WHITE•D.D.S.-B.D.OVARY-ASSESSOR PI K -INSPECTOR GOLDENROD -APPLICANT 1 1 COUNTYOF BUTTE - DEPARTMENTROF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLI•=;f� j , IA 95965 - TELEPHONE (916) 538-7541 u.� a .... t. 'PERMIT APPLICATION DATA SHEET OWNER CPiuck L ���.� i� f4A /i+'1�n/ .� A. P. No. 2- - ?J - %O Proposed Building Use /yC.✓ t%�°S2 5/� Building Inspector L- DateEll 94 Z At time of permit application, I was advised the following data must be submitted prior'to permit processing and/or issuance: `4•r Y DATE RECEIVED BY ,-r 1. All items have been submitted. ....... ......., ... . 2. Plot plans, 3/4 sets, signed by preparer of plans. ................. 3. Complete plans, 3/4 sets, signed by preparer of plans. ......... ............. 4. Engineered plans and'calcs, 3/4 sets, with wet signature on plans. %............ ' 5. Hazardous Material Form . ........................................... . &:� n' rgy Design Compliance and supporting documentation. ...:............. . 7. r Statement,of Intent for Non -Heated and A/C Buildings. ......'...: .......... . 8, E'ngineere'd truss details and layout in duplicate (required prior to plan check). .... 9. Mobilehome data and manufacturer's installation instructions, 2 sets. ... `...... . Feesof $ r ......................................... . 7ig11. Impact fees as shown on attached schedule . ............................. . 12. California Department of Forestry plan approval/fees. ....................... . 3. Flood elevation letter (100 year flood) y California Engineer. .. ............. ' H11- 0 14. S nitation and plot plan approval Health Department . ............ ity of Chico plumbing permit. .............................:.......... . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: ......... 18. Contact Land Development about (A) Improvements (B) Drainage. ....... 9. Driveway permit (construction approval required prior to occupancy). .. ": ""A'.... Pre4nspection requ�- 20. Pre -inspection for required. .. to Building inspector (Date) 21. Contractor's license information. No., Name Style, Classification . .............. Certificate of Workmans Compe satiori Insurance . ......................... . Owner -Builder Verification (Given to owner , Mail to owner _). .......... . . Recorded copy of Agricultural Acknowledgement Statement . .................. r;25. Letter of signature authorization . ............................. . . . . . . . . . . . . Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance. ........... ~ ............................. . 29. Documentation of legal access . ............ . 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ................ Existing violations/expired permits . ....................... 32. Plan check kst..................................... .... .....� � 33. 34. - When ou issue the permit, process as follows: Mail to owner. Mail to contractor. Telephone J y1- V)Q and hold for pickup at office. Deliver with inspector. rA - Other Parcel Creation 1` Acreage Applicant Date -� t. 9S <. Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of ,plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. /TI t 2. Additional items required: Contractor, designer, owner, was advised of above required data by _.phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _mail Counter by _ Date Plans checked -by,. Date Plans approved by Date `, Sets of plans on hold in File cabinet AP folder Copy Department of Public Works J TO: Building Department 96 I/ZI Q FROM: EncroachmentPermitSection 41A �RE- Driveway Clearance Z, ez, 2-7 owner location tj AP # Driveway permit ��Q 3 Z has been issued for the above property. s ature date TO: Building Department FROM: Environmental Health E.H. USE ONLY Plot PLn AttacW Floor Plan AttwW Seat to B.D. / SUBJECT: Sanitation Clearance ma rt 12-/.3-0 Owner Locatin AN Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for bedroom mobile, home. Other Hold final for: Final clearance O.K. for: �5 SP jht NOTE: Enviro5fdental HeaSpecialist Date J i r 1• f y � k • • • i 1 1 r 4 4 � J 1• 6 J cn � Yam J 07-0615 10:1 nAM PFROM MID-VAn'E:Y` °TI LTE T(1'h'iiiFj 1 ' � ?full/lif)4 * Mid Valley Title and Escrow Co. Chico Office Phone (916) 893-5644 Customer Service Only (916) 893-0] 55 * Fax (916) 893-1853 * # Date: Tune' :�LL-> * To: * Company Name * l From * Fax Nwriber: # of pages being sent: Including this Cover Sheet. * Notes: _ * 1� This fax is from the Customer Service Department „'""” Y'+�► STK' '' a � "1�/`1 +ohm q t BUTTE COUNTY PARRS DEVELOPWW FEE CERTIFICATION FORM CHICO AREA RECREATION AND -PARK DISTRICT Assessor Parcel Number(s) y2 ' �3 - Z799 Property Owner N,5'&A /* Project Location/Address 04 A ".I Subdivision x- Lot Number(s) Residential Development 1(0eck,one) tAkr ew Development _Alteration/Addition _Mobilehome(s) _Non -Residential 'e. to Residential Total Number of Dwelling'Units Comment: B i Department Representative ate Chico Area Recreation and Park District(CARD) certifies that 4 ,b &b6f5C�:J GonIST.) 3 V?_ -61.3s) -'(Applicant-Name Phone Number K - , (Street Address), (0 -CA (City) (State) (Zip Code) has complied with'the requirements of Butte Co. Resolution No. 90-140 by payment for ' dwelling units.@ $1,189 for total payment of $ CARD Represent t Date PAID BY CHECK NO. REMARKS: BANK N0. PAID BY CASH' RECEIPT NO. Distribution: White --Applicant Pink --CARD park.fee (form revised 11/90) ;s Yellow--Butte Co. Building Dept. Goldenrod --City of Chico Building Dept. 07105195 P:16RH 001.4#0664 CHECK #11,4 - +--r+ray.:r+�:V:uP�r•Y•erv+r.7anyT�.:e!^3icfSi4�p'�C�t'h'Y�'`S`trxfbf�vYs-+�'r i BUTTE COUNTY SCHOOIeSNWP�ACT FEE CERTIFICATION FORM (One Form.. Pii i$uilding) School District C#/4 O Building bepartment No. A.P. Number �jl Z - / =J- 7 Jurisdiction ❑xK City [County Property Owner Ck/ UG kr 1%6. e -/MA Property Location/Address Subdivison;l ' Lot No. Residential Development ; Q ❑ ❑ Sq. Footage No. of Living MHI Addition (Group R) • Units Commercial/Industrial ❑ ❑ Sq. Footage New Addition (Including Exterior Roofed Areas) Build ng Department Representative Date .� (Floor Plans reviewed by School District Personnel) a - r District Identification No. X6000 OU0 UP�hao_t�) School District certifies that 1 /ND&?S;i:yJ�-U�� s;{ (Applicant) (Street Address) (Phone Number) CHI 160 95` 7 3 (City) / (State) n , / (Zip Code) has complied with the requirements of Resolution No. �t%7 '97 61615c]-g9- representing 1 6 5 c] g — P q by payment of $ ��i. � v - P representing ,38 I/ square feet. ❑ Check here if fee received represents "Full Mitigation". L6 A;s School District Representative Date Paid by Check # Remarks: '�- Bank Number Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under. the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.wkl (4/84) COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DMSION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 - TELEPHONE (916) 538-7541 OWNER A. P. # `ToZ -/ 3 — 7e) PROPOSED BUILDING USE DATE I_ REC. # DATE REC 6 k� 1. SCHOOL DISTRICT FEES l LO /- -71S (paid at District Office) .......................... SHEiIFF R�ildin De artment _ (paid at u g . p ) 2/ Residential...... I x =$ 3Ca 0 1®T� unit amt. Commercial (sgft) z =$ sq.ft'. amt. 3.- URBAN AREA FEES (paid at Building Department) Residential (per unit) x =$ # units amt. Commercial (per sq.ft) x =$ sq.ft. amt. 4. RECREATION DISTRICT FEES (paid at District Office)........................./0 J �S 5. DRAINAGE DISTRICT FEES (Contact Land Development Division) .............. 6. SRA FIRE INSPECTION AND PLAN CHECK = $89.00...... (paid at Building Department) 7. OTHER 8. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. APPLICANT DATE n7—H,-q5 I iI :LOAM FROM MID—VALL'Y T I T L' TO 89561 1 / !'llllc/111.14 r • 95-1192 2 Recording requested by: Ri#148268yTRHile 95-020192: Rea Fee 12.00 And wttcn fet:nfded lull) t0: ( Check 12. 00 Building Disii;Wtt Recorded I Ott 07 Count) Center Drive County Records 1 Go OroB silk. Cs 95963 Butte nut 1 tt• 1 Candace J. Grubbs 1 Recorder 1 a=ooae 19 -Jun -95 I NYTC nr 3 &Q1t1CULT4IRAL STATEMENT OF AGKNOWLED)GMENT FOR R£SIDENTLAL REVELQPWENT Section 26-8 of the Butte County Code requires thus acknowledgment to be lrmrdcprior to issuarwe of a building petrttit. Tbc property described herein is adjacent to land or included aittun an arca zoned for agncultural purposes. and residents of taus property may be subject to inconveniences or discomfort from the use of agricultural chemicals. tnciud,ng. but not limited to herbicitles, pesticides. and fenilizers: and from the purstut of agricultural operations including. but not limited to cub auon. plowing spraying. pruning_ and hamcsung which occasionally generate dust. smoke. noise. and odor Butte County has establrshod agneullunll purposes and residents ",%thin lard none,: and on adjacent property- should be prepared to . Crept such incomemence or discomfort from not•tttal. necessary farm operations. All that real property sttupw in the County of Butte. State of California, describod as follows: SEE ATTACHED LEGAL DESCRIPTION AP8042-130070 Dalt' �' '4zzffl --57— Static of California ) Count. of Butte ) on 6/9/95 before me. Tama Harlow penonall. appe,tt•ed ._Charles S.__Mt'_r_rimem and Linda J. Merriman peraonalh kAowo to rwe (or proved to me on the haai. of .alisfaclo" cvidcntt) to be the per-ina0) whn•e narrte(a) i. -dare subscribed to the Mithin inurvmcat and trl.nnwled);ed In me that hekhellhe% executed the same in his/herhheir aulhoritcd capacig(ies), qnd that M hWherllheir .ittnalurcis) on the irtwument, the person(s) or the t:niit.* peon hchalf of which the 1lerstrn(s) acted. clecuted ItK• inalrument. WITNESS sed hand and ttirtcial seat. s>r a��K rex arsrtt c= 'RAMI BARLOW trox.,R. ►vrua � C10400 w tiivnjlurc trrror (lJ. c. -f. rt_e� ta. teal: roOUTTr Mr Gumnnrp•,CpTM Wo'�E.v ,O Ifgt . .. M .- - r - . -�1, t• -- + "_trr `�'r.J.�.,i C"t'�T.: fTt y}r •. tl�..r ,l+f,r wt s.,-rl'.".4n+•:_Jlt" ,i.rr seios-2e c 14" vol Daglsel V?/o—Ee 400431 1 bob-so.7ott ( nbiomor toAzAtio 1 t:n J$nuol 1 011ua 1 oddati*D A noabrfaa 1 iobi000fl AYvu I cc-aat-et oaoos9 :Yd bufaaupo2 palbi000ri OiftT Y0116V.bIM a9T BdiU►to -*I 16a b—lmm nail« b.MA of tf.tiviG talbllu8 veho 1w*73 pcua) to WPM a�) a4MI000 c Z�iiiV ��►_tiYOi' 1�.2A � O .�r'i N�1P w i-� .1wA 1�1:�� 'Irrl:(lN.9Q,t'i'� 1'�..J�ZI'R[�1A tips z1f iu" gnWjud s 10 mor:tttt, of ronq tyft i1 W al mrnab�laonUx calf nitupr *WI gfnuo7 ,,:,9 N1110 "I aotf�-2 Bull b tlnutAm bta .tatogruq Imullumg& sal biros bsq nR nulfrw Wastant td bnsl of Ia=Lt* to am3d bsdmb inq w tnu m,l ion tW Intbulmi :tsmmwb Imin1w^anRc !o Vr. x11 moil noltrsaotub r0 ir7It fJCr.I:= OI txxdu2 ad vl[m Wr" .sour, idw m tmi mil foa f,sd ptbulmo enol mrxlo la mimngc to fianuq sal mad bac :m!Win0 btu .etau rap ,sob*,dso4 bxltddslta sad (lnx17 atf,td tubo bnt otron o4oma Rub wmiorra;t 411tnoas= Axdn gamrtcd bAx-Anututq .$Irl!Ylgi antimAq va ewetasmemaj *.m "SL or bent" ed bluods rtsegasq tnrxtf w va tans Z --A= b&rj nudlra ifm gmm We as wp" tevrfluerrao trlotimmo and Osu*= Atmon morl naimoufb "rwo(to1 tc bcdn=!o ramoLls71* n1i12 ;)"U3 10. Anw:) Wb n, alGtftt ar'go:Q I= f: AI IIA MOMIROM JA03J 03HDATTA 33t3 OTO-oEt-SMU ZA3H'ia►p 890.4q v7� ar»Q `\,. ( nim�tila7loeekf2 of fu(l b f1nta] ..._.- r •---____---- -- e;otY:.Q t?tfi�T_ _ �.ree:tYroi=J,.,�.,_2e�Q1� f10 !t7saan7q ,jtGatYz9F� .L r6n.t.I_ brr; ryr�l��;�,L2_(A�!'tbt17___ batrtygapa Sllsnor»q sdl N bAnwdsq askpi if) '.won wodw 7df sA os Wmbt+s isonsl.stof to rtesd -At no soot of bsrvsq W aw of nwOOA Jel:,(+ar)(u2�gc! beanvaub snAfSrsdkiA to a:mu sAf trstwr,n nArbANsA fsAf em al bf4bII"m4U bats taamvlpot nide« .bs17a L.Innnsq ear dwAw U IIIA -Ad rsoqu l,s1ns -A1 sa stf:,-+:. it -4 %dt ,mviatnivoir 2d1 sop 1419nuis.8eir v*jdIt1741*%d !d tedt , ........ `•Y L.!amurfrWs 741 bvir.4-an J--=: �� "� •'� '� a Iua,11p book bnsti eel f.11W isx• �. ,� «''.,,,l.,...,...��y ; fait ., is-"�•�'"1 .,T�.?-� C1�.\`,� � i►rr.n,eit 07-06-95 10:10AM FROM MID -VALLEY TITLE TO $956512 F003/004 .41 DEBCRZpTZox 95-10191 ORDER NO. BU -148268 TB ALL,THATCERTAIN REAL PROPERTY SITUATE IN THE STATE OF CALTFORNZA, COUNTY OF BUTTE, DESCRIBED AS FOLLOWS: A PORTION OF LAT 24, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "MAP OF THE SEVENTH SUBDIVISION OF THE JOHN BIDWELL RANCHO, NEAR CHICO, BUTTE CO., CALIFORNIA", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 11, 1902, IN BOOK 5 OF MAPS, AT PAGE(S) 29, MORE PARTICULARLY DESCRIBED AS FOLLOWS. COMMENCING AT THE NORTHWEST CORNER OF SAID IAT 24 ON THE CENTERLIN$ OF 070: WAY; 'THENCE SOUTH ALONG THE WESTERLY PROPERTY LINE OF GRID LOT 24, A DISTANCE OF 779.00 FEET TO THE TRUE POINT OF BECINNXNGI THENCE EAST, A DISTANCE OF 378.00 FEET; THENCE SOUTH, A DISTANCE OF 26.00 FEET; THENCE EAST, A DISTANCE OF 282.00 FEET TO A POINT ON T" k-':ASTeRLY PROPERTY Ltng.OF SAID IAT 24; THENCE SOUTH ALONG SAID EASTERLY PROPERTY LINE, A DISTANCE OF 277.4 FEET; THENCE SOUTH 70 DEG. 00f 00^ WEST, A DISTANCE OF 124.013 FEET; THENCE WEST, A DISTANCE OF 543.4 FEET TO A POINT ON THE WESTERLY PROPRRTY LTXV op SAID LOT 24; THENCE NORTH ALONG SAID PROPERTY LINE, A DISTANCE OF 345.84 FEET TO THE TRUE POINT OF BEGINNING. AN FASNT FOR THE PURPOSES OF INGRESS, EGRESS AND PUBLIC UTILITIES ON THE WESTERLY 60 FEET OF LOT 24, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "MAP OF THE SEVENTH SUBDIVISION OF THE JOHN BIDWELL RANCHO, NEAR CHICO, BUTTE CO., CALIFORNIA", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER .11, 1902, TN RCOX K lap' MA -PS, AT PAGE(S) 29 FROM OAK WAY TO THE NORTHERLY LINE OF THE FOLLOWING DESCRIBED PARCEL: A PORTION OF LOUT 24, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "MAP OF THE SEVENTH SUBDIVISION OF THE JOHN BIDWELL RANCHO, NEAR CHICO, BUTTE CO., CALIFORNIA", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 11, 1902, IN BOOK 5 OF MAPS, AT PAGE(S) 29, MORE PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCING AT THE NORTHWEST CORNER OF SAID LOT 24 ON T14E CENTERLINE OF OAK WAY: THENCE SOUTH ALONG THE WESTERLY PROPERTY LINE OF SAID IAT 24, A DISTANCE OF 779.00 FEET TO THE TRUE POINT OF BEGINNINGS THENCE EAST, A DISTANCE OF 378.00 FEET: THENCE SOUTH, A DISTANCE OF 26.00 FEET; THENCE EAST, A DISTANCE OF 282.00 FEET TO A POINT ON THE EASTERLY PROPERTY LINE OF SAID LAT 24; THENCE SOUTH AI4NO SAID CONTINUED 07-06-90 10:10AM FROM MID -VALLEY 'TITLE TO 8956512 P004/004 95-10191 ORDER NO. BU -148268 TH P1 ORL IIs CONTZ"M EASTERLY PROPERTY LINE, A DISTANCE OF 277.4 FEET; THENCE SOUTH 70 DEG. 00' 00" WEST, A DISTANCE OF 124.08 FEET; THENCE WEST, A DISTANCE OF 543.4 FEET TO A POINT ON THE WESTERLY PROPERTY LINE OF SATO LOT 24; THENCE NORTH ALONG SAID PROPERTY LINE, A DISTANCE OF 345.84 FEET TO THE TRUE POINT OF BEGINNING. A PERPETUAL AND EXCLUSIVE EASEMENT TO OPERATE, MAINTAIN, INSPECT, RrPAIR AND REPLACE AN EXISTING WELL AND WATER PIPELINE AND APPURTENANCES, TOO',THER WITH TBI: RIGHT To ENTER UPON TKe SAID EASEMENT WITH WORKERS, TOOLS AND EQUIPMENT FOR SUCH PURPOSES, OVER ALONG AND UNDER THE REAL PROPERTY DESCRIBED AS FOLLOWS: AH EASEMENT 10 FEET WIDE FOR WATER LINE PURPOSES, LYING 5 FEET ON EACH SIDE OF THE FOLLOWING DESCRIBED CENTERLINE: COMMLNCING AT THE NORTHEAST CORNER OF LOT 24AS SHOWN ON Tu^T CERTAIN MAP ENTITLED, "MAP OF THE SEVENTH SUBDIVISION OF THE JOAN BIDWEL,L RANCHO, NEAR CHICO, BUTTE CO., CALIFORNIA", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 11, 1902, IN BOOK 5 OF MAPS, AT STA E(S) 24, BEING ON THE CENTERLINE OF OAK WAY; THENCE SOUTH ALONG THS EASTERLY PROPERTY LINE OF SAID LOT 24, A DISTANCE OF 240.00 THENCE WEST A DISTANCE OF 15.00 FEET TO AN EXISTING WELL AND r PUMP BEING THE TRUE POINT OF BEGINNING; THENCE EAST, A DISTANCE OF =I^ 10,00 FEET; THENCE SOUTH, A DISTANCE OF 565,00 FEET AND THE END OF THIS DESCRIPTION. SAID EASEMENT INCLUDES THE'AREA WITHIN A 20 FOOT DIAMETER CIrtCLZ AROUND SAID WELL. ET40 OF POCUMENT COgUu D of! BUTTE JUN 2 9 1993 Wayne A. Anderson 5 Elverta Circle Chico, CA 95926 Dear Mr. Anderson: 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7266 FAX: (916) 538-2140 June 28, 1993 RE: AP-_42=13-19=ptn. APPLICATION �FOA-DETERMINATION At the regular meeting of the Butte County Development Review Committee held on June 28, 1993, the Commmittee granted a Certificate of Compliance for the above -referenced property. There are 'no conditions, but there will be a note placed on the certificate as follows: "An 80 ft. minimum sanitary well seal will be required on newly --constructed domestic wells to protect groundwater from shallow water -nitrate contamination." There will also be a note to state: "There shall be a 100 ft. building setback from the top of the bank of Lindo Channel." There is a fifteen -day appeal period before this certificate can be recorded, unless you sign and return the enclosed waiver, waiving your right to appeal the committee's decision. Should you have any questions regarding this matter, please contact this office at 538-7266. Very truly yours, ): r_,V _jezt� Stuart Edell Manager,Land Development Division Department of Development Services SE/ds cc Planning Division Environmental Health Department Building Department AWC g, //V ESI -7,�e V r /VaP7 utte, Co 0 a A CLEAN INDOOR AIR ENVIRONMENT FOR A HEALTHIER TOMORROW DEPARTMENT OF PUBLIC HEALTH DIVISION OF ENVIRONMENTAL HEAL'T'H 18-B County Center Drive 1469 Humboldt Road 7 County Center Drive OroviUe, CA 95965 Chico, CA 95928 Oroville, CA 95965 95969 (916) 538-7282 (9 16) 891-2727 (916) 538-7281 FAX (916) 538-2165 FAX (916) 895-6512 FAX (916) 538-2140 June 7, 1995 Gard Anderson 2737 Oak Way Chico, CA 95926 Dear Mr. Anderson: The application which you recently submitted to this department to construct a sewage disp_o-s_a-l,s_ystem on the property located at Oak Way, Chico AFJ-- -4<2-130-070 has been reviewed. A permit$c:a-n-not be_i.s.ss-ued at this time for the following reason(s) . Insufficient or questionable information. Please submit another plot map and two (2) floor plans. If you have any questions, please contact Loralyn Engellenner at the Chico office listed above between 8 and 9am, Monday through Thursday. LIE/dd//septic/anderson cc `-Building Department Wayne Anderson RESIDENTIAL PLAN CHECKING GUIDE 8/91 (S.F., DUPLEX & MISC. ONLY) s �d� Bldg. Permit # 9 OWNER A.P. # 7n -IS -JG Plan Checker Al - GENERAL r, I. Zoning requirements: (sideyards and number of permitted living units). 2. Valuation. 3. Plans signed by designer. 4. Proper description of work on application. 5. Existing violations on property. 6. Items on data sheet. (W.C., fees, Health, Developer Fees, License -law, etc). 7. Recorded notice of violation. PLOTPLAN• GY. Complete parcel size and dimensions. Setbacks, sideyards, easements, etc. �ther buildings or structures. Grading, fills, drainage. -5-.—Flood hazard. -4.-Special conditions on creation map, (noise, CDF, fire sprinklers, non-comb- ustible, and foundations). 7:�.—.FAU & FAS road setback. j8! Building or utilities across lot lines (Record form). FLOOR PLAN Complete to scale plan with dimensions. . /Required windows for light 4'and'ventilation (Sec. 1205). .3� Required windows for second exit (Sec. 1204). Skylights (Chapter 34 & Sec. 5207). - //Human impact glass (Sec. 5406). b� Required room sizes, ceiling heights (Sec. 1207). ;: GFCIs in baths, garage, kitchen, and exterior outlets (Article 210-8). Light fixtures, switches, receptacles, and exterior receptacles for main- /tenance of mechanical equipment. �: Locations of water heater, heating and cooling equipment, other electrical or gas equipment. / Garage firewall, door size, and closer (Sec. 503(d)(3)). I_d- /1 - 3'0" exterior exit door (sec. 3304 (f). Fl replace and wood stove location, alcoves, and clearance. moke detectors (Sec. 1210). . Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS P l Standard bracing or engineered design (Table 25V) /Unusual shape, size, or split level house requiring lateral design. , Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. /foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Y�Elevations and wall construction details complete enough to construct building .1oof construction details complete enough to construct building. ireplace construction details and calcs if necessary. Z.,iA�Rafter ties or bearing ridge beam. Garage door or porch header sizes. Stud heights. soils - special foundation design. ��idobeetaining walls requiring design. Inspection required. 8/91 RESIDENTIAL PLAN CHECKING GUIDE MISC LANEOUS ITEMS TO LOOK OUT FOR airway details: landings, rise and run, head clearance, handrails r ec. 3306). uardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). Exterior plaster - weep screeds (Sec. 4706). 5( 'roper roof pitch for roof convering (Chapter 32). �Roof covering type - (fire hazard). 7. Foam insulation - protection. $� 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts, etc. L00wo exits on three-story dwellings (sec. 3303 & see Mezannines - 1716). W Attic access and ventilation (Sec. 3205). nderfloor access and ventilation (Sec. 2516). ombustion air for fuel burning appliances - L.P.G. requirements. oise requirements on duplexes. Energy design. Flashing at all exterior openings. 1 CDF responsible area requirements.