Loading...
HomeMy WebLinkAbout043-720-010owet4� 0 I o 0 a L c � U EA "COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING IVISION IO O ` T, `7 County Center Drive Oroville,.California 95965 • Telephone (530) 538-7541ag ,PAAR, 10. (Rev 12/96) ��' APPLICATION AND`PERMIT ASSESsoRPARCEL NUMBER . - •. - 043-720-010 ZONING - - BUILDING PERMIT OWNER LANA, PETER TELEPHONE 89.4-8564 SO. FT. OCC. BUILDING VALUATION 720 U ` '12 96 . OWNERS'MAIUNG ADDRESS - .1620 LAZY TRAIL DR., CHICO CA 9592650 C. 650.00 CONTRACTOR'S NAMETELEPHONE - _ - - `ADDRESS. 415 • R3 22,410.00 '..-32' COMP 1920.00- CONTRACTOR'S •MAILING CONSTRUCTION LENDER -.- Fireplace .. LENDER'S MAILING ADDRESS _ Total Valuation - $ 41,9 0.00 ARCHITECT OR ENGINEER, LICENSE NO. Filing Fee $ 20.00 Permit Fee $362,50 ARCHITECT OR ENGINEERS MAILING ADDRESS) f' Plan Checking Fee $215-61 BUILDING ADDRESS I 1620 LAZY TRAIL DR., CHICO Energy Plan Checking Fee $2-1,00 $ PERMIT FEE LOT NO. SUBDIVISIONS NOME PARCEL MAP Filing PLUMBING PERMIT 9 Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE ° SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ - osfalla,!p .0 Other Other ❑ Describe Work: NEW GARAGE & ATTACHED TO EX RESIDENCE. Gas piping system 1 - 5 outlets 15.00 Buildingsewer 15.00 Mobile Home S G W 920.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service �coAv oA LEss 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter .9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjurythat I am exempt from.the Contractors License Law for the following reason:I ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ I am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. SO OR ACDNS. ( a ACC. BUDS. 3.5¢Fr. 39.17 NONfiE4ID. MULTFOUTLET @7,50 POWER APPARATUS a 8 W GLE OIITLE7 CIR. CUTLET OR Ex. Occup. SAL 0'1: 0 Ex. Occup. ams' o E, 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring23.00 PERMIT FEE $ 59.17 WORKERS' COMPENSATION DECLARATION 1 hereby affirm Linder penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed R the permit is for work of a valuation of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is Issued, I shall not employ any person in any r so as to become subject to workers' compensatio aws of.Cal'rfor ' , and gree that if I should become subject to the workers'; m ensati ovisio of section 3700 of the Labor Code,' I shall forthw' o pl ose isions. / .�1 X Date (" �p V Si at re ppli n - Owner ', O -Contractor p Agent n O p rm' ' requir for excavations over 5'0"deep and demolitio or cons u 'on o structure er 3 stories in eight Receipt No. 53�� .I �' MECHANICAL PERMIT Filing Fee .20.00 Heating Cooling Hood 6.50 Ventilation " PERMIT FEIE $ 50.00 Mobile Home Installation Fee $ Energy Inspection Fee $46.00 OCC CONST. TYPE TOTAL FEE_$ 96,30 VN J . D. VFoIM c PAR E This permit is hereby Issued under the applicable provisions of the Butte County Code and/or Resolutions to do work Indic ove or w 'ch fees have been paid. r ,.i1 B Date b v'i PERMIT EXPIRES ON 5 at WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINKJIFSPECTOR . ' GOLDEN ROD -APPLICANT ' Feb 01 02 08:13a P. a01 ;COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION - 7 County Center Drive Oroville, California 95965 •Telephone (530) 538-754 PE 0. 09ev.12/96) APPLICATION AND PERMIT . "�a°�' n 1 % 1/�C 2pH1NO /j��j e. ,f B.yUILDING R SQ.'FT. OCC. BU DING VALUATION ' 60 2 NERC. " W..0 vCONSTRUCTIONLENDER TKA CAI C 0 CONTRACTOR'S NAME -..CONTRACTORS MM" ADM$$ - LENDERS M UNG ADDRESS - _- Fireplace Total Valuation S . ARCHrTECT OR ENOb1EO1 LICENSE NO. - Fling Fee $ 20.00 ARCHTECT OR ENGINEER'S LLWNG ADDRESS _ Permit Fee a Plan Checkin Fee. euao noo 9 � T��l or / Energy Plan Checking fee $ . (� . ai -- _ IN Gr C -H 1� tC-6l(--` - • S PERMIT FEE S LOTNO SUBDIM191ONSN41AE AROEL MW PLUMBING PERMIT Filing Fee 1 20.00 USEOFSTRUCTURE SF 0 Duplex ❑ Mobilehome ❑ Other sPEosv Each Trap 1 7.001 __— Solar or heat pump water heater 1 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ ,*Utilities ❑ Ir>alte9a, n 0 other ❑ // Describe Work: ti� Q► Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I WT ­Q20.00 PERMIT FEE s ELECTRICAL PERMIT Filing Fee 20.00 -- Main Service •o0V OR LESS oow oR .ss 23.00 �� *P FEE I ``1�� (_X` /vf S� SHMFF ¢ arm. � AA REb �lL -h/ ` • - TO 1111a 1" COQI [I Main Service 200A TO 1000A 46.00 NEW CON0 . DwtllJPq OCCUP. 3.SQ so. OR ADDNS. 8 ACO. BLD.. FT. muLT;' O, LET NOHAEs1D. ®7.50; MNMAPPARATUS 8 .IN OUTLET CR xo p 1. 0oo Ex. Occup. ouner OR FtxruRE. SAL 0 5 —Temporary FUCED APPLN9. OR Ex. o°°u o� SID. � S.00 Service 23.00 –� Mobile Home Facilities 20.00 _ Misc. Wirin �� 23,00 7_ PER IT FEE i MECHANICAL PER T Filing Fee 20.00 Heating ,&D �QO Coolin •,.. Hood 6.50 ; Ventilation PERMIT FOE S O.(iO Mobile Home Installation Fee S Energy Inspection Fee I S lc O0 `PE TO AL FEE $ 11A%2. , FE FL D CDF EL HD SUE IV/1 This permit is hereby Issued under the applicable provisions .. of the. Butte County Code and/or Resolutions to do work Indicated above for which fees have been paid. - By Date PERMIT EXPIRES ON To Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR OOLDENROD•APPLICANT °Lr . i .�: 1.,L��:..'.'ra+l�::v,�--'-.'"•."'r^,;.H..� "�Y`i. t..w fit+ ,rvY, r� �' •`��`;fi�-^"��..;-i:�;-�- �'•..�. t �„ � c. ;n:�: c... COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SLRVICES-BUILDING DIVISION 7'County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: ���J , 1 ASSESSOR PARCEL NUMBER O43_" Proposed Building Use: r • Counter Technician: 01,&&AV Date: 6) �Vy Items required in order to apply for a permit. All boxes MUST be checked OR. marked NA in order to apply. C'l1. of plans, or 4 set �ned by the preparer of the plans. Com. Complete plans, 915r 4 sets, signed by the preparer of the plans. 143. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. 4. Engineered truss details and layouts in duplicate. No faxes! 5 Energy compliance design and supporting documentation in duplicate. . Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. IV, NX T. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed b tengineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required items are received. Date Received By ❑ 8. Flood Elevation Certificate, wet-stamped.and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings.......................................................... ❑ 11. Detached Accessory Building Form filled. out by the owner ...................................... ❑ 12. Hazardous Material Form.....................................................:......................... ❑ 13. Other ' ing items needed to issue the permit. (May require additional plan review upon receipt of the followi items.) 4. Fees as shown on the attached Schedule of Fees Due Sheet. . .. .................................... 10-f d1_1 .❑ 1 . Statement of Intent for Non -heated and A/C Buildings ................................ eN I A. . 16. Sanitation and, plot plan approval from the Environmental Health Department in *+ ❑ 17. City of Chico Plumbing permit...................................................................... ❑ 18. California Department of Forestry plan approval ❑ paid. Sent by: ...................... ❑ 19. Planning approval for (A) Use: 4 K (B)Parking: (C) Parcel Check: ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... ❑ 21'. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... ❑ 26. Letter of Signature authorization.................................................................... ❑ 27. Recorded copy of Agricultural Acknowledgment Statement .................................... ❑ 28. Manufactured home utility clearance............................................................... _ ❑ 29. Existing violations and/or expired permits.......................................................... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: _ When issued Telephone and hold for pickup. I have been informe �ite nd requirements for obtaining a building permit. .e q g gP 1_�710LY .il_� Xpplicant: Date: Cly a2 ®y 1. Index erm Vequired on for the above items numbered: Yt7lan Wck Letter P 2. Addit item Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the above ata by ❑, phone, El mail, ❑ counter, by Date: Plans reviewed by: Date: • • i Plans approved by: Date: Structural reviewed by: Date: Structural :approved by: Dater /1 &0 Note transfer by: Date: Yellow: Building Division 11 E.N. USE ONLY Plot Pian Attached W �.. Floor Plan Attache Fry Som to D.D. TO: Building Department FROM: Environmental Health SUBJECT: Sanitation yClearance -72-0 - 0 l0 Owner 1 - cation AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well ClearAnce for dwelling. Other Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist Date 8/96 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE OWNER A.P. # PROPOSED UILDING USE DING PERMIT FEES Balance Due ....................... $ _ Additional Fees Due ................. $ _ Additional Fees Due .. ............. $ _ Revised Plan Checking Fee .............$ _ 2. SCHOOL DISTRICT FEES (paid at District Office) (Available after Plan Check) 3. SHERIFF FEES (paid at Building Division) 54. 09 Residential ...................... -x$360.00=$ Units Commercial (sq. ft.) ............... x $0.03 = $ Sq. ft. 4. URBAN AREA FEES (paid at Building Division) Residential ................... -x-=$ # Units Amt. Commercial (sq. ft.) ............ -x-=$ Sq. ft. Amt. DATE RECEIPT # DATE REC. 5. RECREATIONAL DISTRICT FEES ti (paid at District Office) (Available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 6/00) .r-.-- < ...,w.;,+.—.•. -.y -v ,....- { .:-.-:::K�•�......-...--� .—.-, _. - acs+v��W;Tf,.x.4.wes.�v'-v.rvw-'^.+++-:�,,,.,"+}=F.�:M...::•�i-6r.�,:.u'-w.-, ti:..,.!_. ..Y�� L COUNTY OF BUTTE ` DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION * t , COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE PROPOSED BUILDING USE BUILDING PERMIT FEES: t 1 ` } Balance Due ....................... $ ( ' Additional Fees Due ................. $ Additional Fees Due ......:.......... $ Revised Plan Checking Fee .............$ 2. -SCHOOL DISTRICT FEES (paid at District Office) (Available after Plan Check) 3. SHERIFF{FEES (paid at Building Division) Residential :....................... x $360.00 = $ Units Commercial (sq. ft.) ............... x $0.03 = $ Sq.ft. 4. URBAN AREA FEES (paid at Building Division) Residential .................... -x-=$ # Units Amt. Commercial (sq. ft.) ............ -x_=$ Sq. ft. Amt. 5. RECREATIONAL DISTRICT FEES (paid at District Office) (Available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER A.P. # DATE # DATE REC. RECEIPT r4 ac-/ At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE Pursuant to Government Code Section 66020, you are hereby notified that items 2,:3, 4, 5, 6_71 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project of from the imposition of the above mentioned items during which -you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner (Rev. 6/00) BUTTE. COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Bullding) School, District.— CBuilding Department No. A.P. Number ;'f� Jurisdiction: 0 city County P Pe rortj! Owner �f �V.� `��` Property LocatioNAddress y Subdivision Lot No. Residential Development �.= i _ Sq. Footage No of,L•rving Mobile Home itioN *Supplemental to (Group R) Units Installation Conversion Permit # '(No foundation ins i Commercial/.Industrial Sq. Footage . New Addition. (Including F)derior Roofed Areas) Building Department Representative Date (Floor Plans reviewed by School District Personnel) Distnct'Identification•No. School District certifies`that-Q/C�l/ (Applicant) (Street Address) (Phone Number) ;(.City) (State) (zip Cod e) has complied with the requirements of Resolution No. by payment of $ representing. / l./ square feet. 2826 $ LL MITIGATION ; �- School District Representative Date Paid by Check # Remarks:(�C�C��/� Notfice: You may protest the imposition of the fees identified above by submitting a written protest to the District,. in compliance with. Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written.protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project Is being reviewed under the California Environmental Quality Act (CEQA), this project may. be subject to additional school fees-to fully, mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.x(s (10/98)dmm �/ LE ` VERTECH ENGINEERING :PROJECT:". -"8/16/02 ' STRUCTURAL NOTES t 1.. GENERAL # A) ; : " .ALLWORK SHALL CONFORM TO.,,THE 1997:,UBC-AND ALL APPLICABLE LOCAL CODES; B) " THE ENGINEER (VERTECH ENGINEERING) IS" FOR THE STRUCTURAL ITEMS IN THE PLANS , ONLY SHOULD ANY CHANGES BE:MADE FROM THE DESIGNAS;SPECIFIED'IN.THESECALCULATIONS.>. v WITHOUT:THE 1NRITTEN APPROVAL°fROMTHE ENGINEER, -THEN�THE ENGINEER,WILL ASSUME NO-' 4 RESPONSIBILITY"fOR ANY-ELEMENT.OR SYSTEM OPTHE IS," ,C) DRAWING;S'AJ4D CALCULATIONS,REPTHE 'FINISHED STRUCTURE AND; UNLESS SPECIFICALLY: NOTED OTHE�WIS1=;-DOiNOT SHOW THE METHOD.OF CONSTRUCTION.' THE�CONTRACTOR IS RESPONSIBLE t ' `FOR'THE`METHOD'OF CONSTRUCTION-ANDSHALL;PROVI DE ALL:MEASURES NECESSARY,TO PROTECT.THE <; - -THE .RESENT PUBLIC, CONSTRLICTION ;WORKERS;,AND.THE STRUCTURE, DURING CONSTRUCTION., SUCH MEASURES SHALL INCLUDEfORMING, SHORING, BRACING; SCAFFOLDING, ETC. IF.A PART ICULARrEATURE'OF CONSTRUCTION ISNOT FULLY'SHOWN ON THE DRAWINGS OR IN THE • CALCULATIONS,,THEN IT SHALL BE CONSTRUCTED INTHE SAME'CHARACTER AS'SIMILAR CONDITIONS THAT 'ARE SHOWN ON THE DESIGN"DOCUMENTS. " - E) = . --ANY,.CONDITIONS'VOTED AS, EXISTING MUST BE FIELD VERIFIED BY THE C.ONTRACTOR,`AND ANY " _DISCREPANC.ES`MUST BE BROUGHT TO THE ATTENTION OF.THE ENGINEER WITHOUT PROCEEDINGWITH OONSTRUCTIJN PRIOR TO THE REVIEW OF. THE ENGINEER. " r F) ALLWATER.PROOFING AND FLASHING -(ROOFS, FOUNDATIONS,- GARAGE FLOORS ETC )-IS THE ` RESPONSIBILITY,"OF THE CONTRACTOR OR OWNER. 2: SITE WORK. /FOUNDATIONS " A) - ASSUMEDWAXIMUM SOIL BEARINGi::, 1000'PSF PER UBC TABLE 18 1-A B) -,`BUILDING SITE IS ASSUMEDTO BE DRAINED AND" FREE OF CLAY OR EXPANSIVE -SOIL. ENGINEER HAS NOT MApEA GEOTECHNICAL REVIEW ,OF;SITE, ANY OTHER CONDITIONS ENCOUNTERED MUST BE BROUGHT TO, TH(ATTENTION OF THE ENGINEER. ` C) THESE CALCULATIONS ASSUME STABLE,. UNDISTURBED SOILS, AND, LEVELOR STEPPED FOOTINGS. ANY OTHER CONDITIONS SHOULD BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR•TO THE -'- CONSTRUCTION'OF THE FOUNDATIONS. D) " ALL FOOTINGS INCLUDING RETAINING WALL FOOTINGS; SPREAD FOOTINGS, WALL FOOTINGS, AND GRADE BEAMS SHALL.BEAR,ON UNDISTURBED SOIL WITH A FOOTING -DEPTH BELOW-FROSTLINE (127 TO"24"AS-PER ' LOCAL REQUIREMENTS) , E) . BOTTOM OF ALL FOUNDATION TRENCHES SHALL BE CLEAN AND LEVEL":-.' F) ALCFINISHED GRADE SHALL SLOPE AT A• MINIMUM SLOPE OF•2% AWAY FROM ALL FOUNDATIONS.A,MINIMUM OF;10 FEET HDRIZONTAL.. FOUNDATIONSSHALL-NOT _BE'SCALED FROM PLAN OR DETAIL DRAWINGS. ,: u H) FILL MATERIAL SHALL BE:FREE FROM DEBRIS; VEGETATION, AND,OTHER FOREIGN;SUBSTANCES.; 1) USE 4 DIAMETERmRLRFORATED"PIPE SUB -DRAIN BEHIND ALL RETAINING WALLS. SLOPE PIPE ''d:DRAIN TO ' DAYLIGHT 'r 4. CONCRETE I REINFORCING " A) " f CONCRETE S'HALL,HAVE A.MiNIMUM;28 DAY STRENGTH OFf '2 500 PS1 U N 0..., C) ALL CEMENT .JSEU-S`HALL CONFORM,TO,'ASTM "C-150 AND'SHALL'4BE TYPE II OR TYPE III LOW ALKALI D) AGGREGATE SHAI',L CONFORM TO:ASTM C-33 AND SHALL NOT CONTAIN MATERIALS WHICH ARE ALKALI :REACTIVE AS DETERMINED BY ASTM C-227; 289, AND 295. IF TEST:DATA1S UNAVAILABLE IN. REGARDS TO -ALKALI REACTIVE MATERIALS PROVIDE CEMENT WITH A MAXIMUM ALKALI,CONTENT'LESS THAN 0!45% BY WEIGHT A .E) CONCRETEEKCPO5ED TO FREEZING OR THAWING SHALL,BE PROTECTED IN ACCORDANCE TO THE LATEST EDITION OF THE ACI CODE AND,UBC"APPENDIX, CHAPTER 19' F) SLABS ON'GRADE SHALL BE,PER THE CONTRACTOR. VERTECH RECOMMENDS THE FOLLOWING ASA ,SUITABLE SLAB OIV'GRADE .,AT GARAGE SLABS;`USE 4'' THICK S.-O.G. WITH#3 BARS, AT 15`- O.C:, EACH WA MOISTURE BARIER,'OVER 4" AGGREGATE`BASE: USE 3-12 _ SLAB WITIHD# ATF 50E W BOVE MID DEPT"OFR SLAB "OR,6X6•WWF ABOVE MID=DEPTH OF SLAB WITH SAME SUIB=SLABBUILDUP AT ALLOTHER AREAS:. - ' ' ' " a'- G)"-= = SAW -CUTTOP'/. F SLAB`F I R,CRACK CONTROL AT'INTERVAL•S NOT TO EXCEED.20'-0'-WHERE"SLAB Is,., REINFORCED "SAWCUT AT -INTERVALS NOT TO EXCEED 7'=0'WHERE SLAB IS UN REINFORCED I)REINFORCEMENT COVER SHALLBE AS FOLLOWS: CONCRETE,C.ASTAGAINST AND PERMANENTLY EXPOSED TO,SOIL. 3 ,CONCRETE'\AIITHSOIL OR'WEPTHER"EXPOSURE>#5 BARS AND.SMALLER 1`Y: #6 BARS'AND LARGER CONCRETE WITHOUT SOIL OR WEATHER EXPOSURE '/.', J) „ REINFORCEMENT SHALL BE GRADE 60"PER ASTM A615 U.N.O. LAP.REINFORCING 40 BAR DIAMETERS U.N'O K) " 45;AND LARGER REBAR SHALL NOT BE RE=BENT."` L) ALL REINFOR ANDANCHOR BOLTS SHALL BEACCURATELY LOCATED -AND ADEQUATELY ,INt!STEEL SECURED INPOSITION BEFORE AND DURING CONCRETE PLACEMENT. r v4r VERTECH ENGINEERING PROJECT: .8/16/02 .5. MASONRY A)CEMENT MASONRY UNITS SHALL CONFORM TO UBC STANDARD 21-4, GRADER TYPE I, AND, SHALL BE SINGLE OR DOUBLE OPEN END BOND BEAM UNITS. B) F'm MIN SHALL BE 1,500 PSI WITH COMPLIANCE VERIFIED AS REQUIRED PER UBC SECTION 2105:3:_ C) EACH CELL SHALL BE COMPLETELY,FILLED'WITH GROUT CONFORMING TO ASTM C279 TYPES WITH A'. MINIMUM STRENGTH OF 2,000 PSI.` D) LAP REINFORCING THE GREATER OF 60 BAR DIAMETERS •OR 2'-0'. -.E) . LOCATE ANCHOR BOLTS WITHIN 2" OF THE CENTER OF A CELL. 6. ,FRAMINGILUMBER 6-1 MATERIALS:' A:) SHEATHING: .1.ROOF SHEATHING: SEE PLANS 2., FLOOR SHEATHING: SEE PLANS 3. WALL SHEATHING: SEE PLANS B.) GLUE -LAMS: GLUE -LAMS SHALL BE 24F -V4 U.N.O. WITH A CAMBER OF R=1600' U.N.O. GLUE -LAMS EXPOSED TO WEATHER MUST BE RATED FOR EXTERIOR USE BY THE MANUFACTURER:. GLUED LAMINATED FABRICATON SHALL BE PERFORMED IN AN APPROVED FABRICATORS SHOP IN ACCORDANCE WITH UBC 1761.7 AND UBC 2304.4.3. BEAM INSPECTION CERTIFICATES SHALL BE SUBMITTED TO,THE FIELC INSPECTOR PRIOR TO COMPLETION OF FRAME INSPECTION IN ACCORDANCE WITH UBC . -1704.6.2. �C.) MICRO -LAMS: MICRO -LAMS (LAMINATED VENEER LUMBER) SHALL HAVE FB = 2800 PSI & FV = 285 PS[ MIN., AND SHALL BE MANUFACTURED, APPROVED AND IDENTIFIED AS PER NER-481 D.) SILL PLATES: SILL PLATES SHALL BE PRESSURE TREATED DOUGLAS FIR WITH 1/2" DIAMETER ANCHOR BOLTS AND 2" X 2" X 3/16" PLATE WASHERS LOCATED AT 4'.-0" O.C. MAX. WITH ONE BOLT LOCATED 1'-0" MAXIMUM FROM EACH END OF EACH PIECE. E.) FRAMING LUMBER: ALL FRAMING LUMBER SHALL BE DOUGLAS FIR LARCH AS GRADED BY THE W.W.P.A. OR W.C.L.I.B. AND SHALL HAVE A MOISTURE CONTENT LESS THAN 19%, U.N.O. 1. STUDS SHALL BE STUD GRADE OR BETTER. 2. ALL POSTS SHALL BE DF -L #1 U.N.O. •3. 2X AND 3X RAFTERS SHALL BE DF -L #2 U.N.O. 4. 2X JOISTS SHALL BE DF -L #2 U.N:O. 5. CONCEALED BEAMS SHALL BE DF -L #2 6., EXPOSED BEAMS SHALL BE DF -L #1 APPEARANCE GRADE FOHC (4X6 AND, LARGER) F.) NAILS: ALL NAILS SHALL BE COMMON U.N.O. WHERE EXPOSED TO WEATHER OR WITHIN 18". OF .FOUNDATION, NAILS SHALL BE GALVANIZED. G.) BOLTS AND, LAG SCREWS: BOLTS AND LAG SCREWS SHALL BE ASTM A-307 U.N.O. AND PROVIDED NEW.•AND WITHOUT EXCESSIVE RUST. H.) ', .„ALL HARDWARE CALLED SHALL BE SIMPSON STRONG TIE CO.; OR ENGINEER APPROVED, EQUIVELANT, !!`,'INSTALLED -PER MANUFACTURER'S RECOMMENDATIONS WITH ALL HOLES FILLED WITH, RECOMMENDED FASTENERS I.) MANUFACTURED "I” JOISTS: MANUFACTURED I JOISTS (SUCH AS TRUSS JOISTS) SHALL BE•,INSTALLED PER THE MANUFACTURES RECOMMENDATIONS USING A DEFLECTION LIMIT OF U480 U.N.O. USE A MANUFACTURED 1-1/4" RIM BOARD (SUCH AS TIMBER STRAND) WITH ALL I" JOISTS. -;USE A DOUBLE RIM OR,1 2% LVL'RIM AT ALL LOCATIONS .WHERE LEDGERS ARE USED (SUCH AS DECK LEDGERS):, 6-2 GENERAL FRAMING A:) . MINIMUM NAILING: MINIMUM NAILING SHALL.BE PER 1997 UBC TABLE 23 -II -B-1, B) LARGER MEMBERS: ALL FRAMING MEMBERS SPECIFIED IN THESE CALCULATIONS ARE MINIMUMS,. LARGER MEMBERS MAY BE SUBSTITUTED AT CONTRACTORS OPTION. C.) .;SHRINKAGE: CARE SHALL BE TAKEN TO ALLOW FOR EFFECTS'OF SHRINKAGE WHICH COULD CAUSE SETTLEMENT OF ROOF AND OR FLOORS AND COULD LEAD TO FAILURE OF ASSOCIATED FRAMING MEMBERS. THE CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO PROTECT FRAMING FROM THE F EFFECTS OF SHRINKAGE. 6-3 BEAM•FRAMING.. A.) BUILT UP BEAMS: ALL BUILT UP, LAMINATED DOUBLE OR MULTIPLE 2X JOISTS AND BEAMS SHALL BENAI LED ,TOGETHER WITH 16d NAILS AT 6' O.C., T&B U.N.O. B.) DOUBLE JOISTS: PROVIDE DOUBLE FLOOR JOISTS UNDER PARTITION WALLSRUNNING PARALLEL TO JOIST SPAN AND UNDER ALL LOCATIONS WHERE TUBS MAY BE LOCATED. ADEQUATE SUPPORT SHALL BE PROVIDED FOR ALL OTHER EQUIPMENT OR FURNISHINGS WHICH MAY NOT BE.SHOWN ON THE STRUCTURAL DRAWINGS INCLUDING BUT NOT LIMITED TO`. HOT WATER HEATER, STOVE, REFRIGERATOR, OVEN, FIRE PLACE ENCLOSURES, WOOD BURNING STOVE, ETC... C.) BLOCKING: PROVIDE SOLID BLOCKING IN JOIST FRAMING ABOVE ALL SUPPORTS AND MIDSPAN OF JOISTS SPANNING GREATER THAN 10'-0' VERTECH ENGINEERING PROJECTr 8/16/02-. . 6-4 POSTS/TRIMMERS A.) SUPPORT: SUPPORT ALL UPPER LEVEL POSTS AND TRIMMERS IN LOWER LEVELS WITH EQUIVELANT FRAMING AND BLOCK OR OTHERWISE FRAME POSTS THROUGH*FLOOR•SYSTEMS. B.) . • WHERE POSTS WITH COLUMN CAPS OR BEARING PLATES ARE SPECIFIED; THE'LOAD IS TO BE TRANSFERRED TO THE FOUNDATION BY VERTICAL GRAIN ONLY, U.N:O. 6-5 WALL FRAMING . ' A.) DOUBLE TOP PLATE SPLICES: SPLICES AND JOINTS IN DOUBLE TOP PLATE OF STUD BEARING WALL SHALL OCCUR AT THE CENTER LINE OF SUPPORTING STUD TOP PLATE SPLICES OF STUD WALLS,SHALL BE 48'LONG WITH (12) 16d SINKERS EACH SIDE OF EACH SPLICE U.N.O. WHERE SPLICE IS INTERUPTED; USE ST6224 STRAP U'.N.O. B.) FIRE BLOCKS: FIRE BLOCK STUD WALLS AT MID -HEIGHT WHERE STUD LENGTH EXCEEDS 8'-0" C.) MIS -PLACED ANCHOR BOLTS: WHERE ANCHOR BOLTS HAVE BEEN INCORRECTLY PLACED, USE HILTI QWIK- BOLT II OF SAME DIAMETER WITH EMBEDMENT IN CONCRETE AND INSTALLATION PER MANUFACTURERS RECOMMENDATIONS AND CURRENT ICBO REPORT. CRIPPLE WALLS: CRIPPLE WALLS SHALL BE A MINIMUM OF 14' IN HEIGHT. FOR LESSER HEIGHTS, STACK 2X PLATES (AND SHIM AS REQUIRED). E.) NOTCHED OR CUT STUDS: NOTCHED AND/OR CUT STUDS TO CLEAR ANCHOR BOLTS ARE NOT ALLOWED. STUDS SHALL HAVE FULL BEARING TO THE FOUNDATION PLATE. F.) LET -IN BRACES: LET IN BRACES SHALL NOT BE USED FOR TEMPORARY BRACING ON ANY WALL FRAME. STEEL STRAFS WHICH DO NOT REQUIRE THE CUTTING OF STUDS ARE AN ACCEPTABLE ALTERNATIVE. .'6-6 CONNECTIONS ,) HOLES FOR.THROUGH BOLTS SHALL BE DRILLED 1/16' OVERSIZE. B.) ALL BOLTS, NUTS, AND LAG SCREWS SHALL BE PROVIDED WITH FLAT OR MALLEABLE WASHERS WHERE BEARING AGAINST WOOD. C:) ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED UPON INSTALLATION AND RE -TIGHTENED BEFORE CLOSING IN OR AT COMPLETION OF JOB. D:) LAG SCREWS SHALL BE SCREWED, NOT DRIVEN, INTO PLACE.,' 7. DESIGN LOADS A) ALL DESIGN LOADS ARE PER UBC CHAPTER 16, DIVISIONS I, II; III, AND IV U.N:O. B) ROOF LIVE LOAD/SNOW LOAD: 20 PSF' . . C) SEISMIC ZONE: 3 D) WIND`SPEED:.75 MPH EXP B PROJECT Lana VERTECH `. ENGINEERING PAGE ENGINEER A7 DATE V O DESIGN OF r oo' . O I_ . r ov V.'g 2 , _ -. Ply � "2•� i r� s ul cx orl ` 2 Is " ,x. c, 2,5 rood LL_ '20 Ps wall OL IS., 1997 UBC Wind Loads Wall Elements VerTech Engineering All structures 10.8 11.6 (UBC CH16 DIV III) Enclosed and Unenclosed Structures -10.8 -11.6 Project ' Lana Addition Partially Enclosed -14.3' Date: 8/16/2002. Comments': Parapet,Walls -11.7 .11.7 -12.6 12.6 -13.5:7 13.5 :.. . Roof Elements - Enclosed and Unenclosed Structures Wind.Speed: 75 mph Importance Slope <7:1Z -11.7 Exposure: B 7:12 to 12:12 -11.7. 1.1.7 =12.6 12:6 El one Story or Partially Enclosed Multi-StoryStruMre Partially Enclosed Primary Frame Elevation Elevation Elevation Method A 15 20 25 Windward Wall 7.2 7.8 8.3 Leeward Wall -4.5 -4.8 -5.2 Roof Slope <2:12 -20.6 Leeward or Flat Roof -10.8 -11.6 -12.5-, Windward Roof ?7.12;to12:12 ;-14.3 -15.5 -16.7 Slope <2:12 -10.8 -11.6 -12.5 2:12 to <9:12, -12.6 2:7 -13.6 2.9 -14.6. 3.1 9:12 to 12:12 3.6 3.9 4.2 >12:12 - 6:3 .6.8 7.3 Wind.Parallel to Ridges -10.8 -11.6 -12.5 Method B, On Vertical Projected Area . Structure <= 40' High 11.7 12.6 13.5 Structure .>40' High 12.6 13.6 14.6 On Horizontal Projected Area -10.8 -11.6 -12.5 Elements and Components not in areas of discontinuity Wall Elements All structures 10.8 11.6 12.5 Enclosed and Unenclosed Structures -10.8 -11.6 Partially Enclosed -14.3' -15:5 -16:7 Parapet,Walls -11.7 .11.7 -12.6 12.6 -13.5:7 13.5 :.. . Roof Elements - Enclosed and Unenclosed Structures Slope <7:1Z -11.7 -12:6 713.5 7:12 to 12:12 -11.7. 1.1.7 =12.6 12:6 -13.5 13.5 Partially Enclosed Slope.<2:12 ;F -15.2 -16.5 2:12 to 7:12 -14.3 7.2 -15.5 7.8 -16.7 8.3 >7:12 to: 12:12 -15.2 15.2 -16.5 16.5 -17.7. 17.7 Elements and Components In areas of discontinuity Wali Come,s -13.5 10.8 -14.5 11.6 -15.6 12.5 Roof Eaves, rakes or ridges without overhangs Slope <2:12 -20.6 -22.3 -24.0. F 2:12.to,7:12 -23.3 -25.2 -27.1 ?7.12;to12:12 ;-14.3 -15.5 -16.7 Slope, 212 at overhangs, canopies -25.1 -27.1 -29:2 Soil type = .sd v Soil Profile Types 1= 1, Importance Factor Table 16-K R= 5.5 Overstrength and Ductility Factor Table 16-N or 16-P Ca = 0.36 Seismic Coefficient Table 16-Q Cv = 0.54 Seismic Coefficient Table 16-R hn = 15 _HEIGHT TO ROOF) Ct = C20 FOR ALL OTHERS T -A Ct(hn) Max I 1.4*TA VEQ Ft ='0.07•T'V (If T<.7, Ft -6) =20. 2 EQ• CvURT = 0.6441 0.6459 VIW: VEQ = 7.5 7 V: Ft = 0.00 Ils�i_■�r�MK!Lj= ° ° - Wougn M. Ve�rTech. E'n i n ee ri n g� g Project �n ono►{LL�. Page, .r. l _ Engineer ;4T i h s Date { Desi n of Shear; Walls, Framiri 3' Panel Shear,UNalls' II - _ Resistive A35- Sihl `` " Lateral] WallAttachment Attachment Load♦' ;Len th Len tFi' Len th Lo ft ad 'r Ed e' Nail Wall iL1 Ll . a Ll ILb . ' in A 2001 6:25 . 6.25 ,. 6.25 320 4 . — , , :. _ t i; a R { _ L r. � e Pi,N'REVIE �RESPOle1SE FOS In order to expedite the review'of your plans; please complete the following information and return this form with your re -submittal. .` this form is.not complete, as to all correction items, we will" not be able toaccept your re -submittal for. review. There must be, a vWi response to every item requested in our plan corntion letter. "By others" is _not, considered a valid:'response.. Please indicate yo►,. response, to each item and the location where the information can be found on the plans/calcs: -ATTACH THIS FORM TO A COPY OF YOUR PLAN. REVIEW LETTER AND RETURN WITH REVISED AND ORIGINAL PLANS. NAME OWNERS .: DATE:: ASSESSORS -PARCEL -'NUMBER- PERMIT NUMBER. RESPONSE FOR,'PLAN CHECK LETTER DATED: , PLAN CHECK ITEM # I,VMMtN 1'S:� I . ,2t/i3i1�5 PLAN CHECK ITEM # . . COMMENTS: G 'Par , RESPONSE BY: LOCATION ON PLANS/CALCS: L 0) 1074�_ J� lo_4 RESPONSE BY:. LOCATION ON PLANS/CALCS: 1l; PLAN CHECK ITEM # . RESPONSE BY: LOCATION ON PLANS/CALCS: Sig/Tim? COMMENTS:' - PLAN OMMENTS PLAN CHECK ITEM # RESPONSE BY: LOCATION ON PLANS/CALCS:��-- P p COMMENTS: ;000.y - J vm w + � L PLAN CHECK ITEM N RESPONSE -BY: COMMENTS: PLAN CHECK ITEM N RESPONSE BY: COMMENTS: PLAN CHECK ITEM M RESPONSE BY: COMMENTS: LOCATION ON PLANS/CALCS: L s� F4oe� LOCATION ON PUNS/CALCS: LOCATION ON PUNS/CALCS: ------------ PLAN CHECK ITEM N RESPONSE BY: LOCATION ON PUNS/CALCS: DZ -, RESPONSE FOR PUN CHECK LETTER DATED: PLAN CHECK REM N, RESPONSE BY: LOCATION ON PUNS/CALCS.. COMMENTS:.. � O7if� LL• C^d�"�-/�!/��, "; r„ 1 �' :: �5, /�/i�/�',�+ OF PLAN CHECK ITEM:N , RESPONSE BY:. nLOCATION ON PUNS/CALCS: COMMENTS: LOCATION ON PUNS/CALCS: PLAN CHECK ITEM N _ RESPONSE BY: COMMENTS: L PLAN CHECK ITEM N RESPONSE -BY: COMMENTS: PLAN CHECK ITEM N RESPONSE BY: COMMENTS: PLAN CHECK ITEM M RESPONSE BY: COMMENTS: LOCATION ON PLANS/CALCS: L s� F4oe� LOCATION ON PUNS/CALCS: LOCATION ON PUNS/CALCS: ------------ PLAN CHECK ITEM N RESPONSE BY: LOCATION ON PUNS/CALCS: 1i r �h?<' PERMIT NO 1643-87 PERMIT EXPIRES. - / AWNER _ •�AAUICuER•. CONTR.,'_ ASSESSOR PARCEL42 4918 . LOCATION 620 Lazy Trail Dr, Chico � OFFICE COPY ' r Address�lC1 GAS Meter By Date ELECTRIC Meter By Date • ?t,;j. OFFI` CE COPY c: Address ' GAS �. Meter By at E L E C T R I C J% ` Meter By �— Date _ Temp Power Polo.', Called PG&E' 4• Temp. Elec: Service Called PGBE Temp..Gae Service.. _ 0 1; . cill6d PG&E j, _ I r OB FINALED (Date) Signature OK 0 —Not OK. - = Not Applicable = Not Ready MOBILE HOMES MISCELLANEOUS Date : MOBILE 'HOME UTILITIES (Plarfsy:0K excepts#'s,-. _ ;Date DECKS,COVERS,CARPORTS,GARAGES, (Plan OK except #'s 1:,Z6ning•,Requirements-Setbacks-Easements 1. Zoning Requirements -Setbacks -Easements 2 `Soils; Special'MH Support -Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Sewer; Location-Test-Fall,C/O-Concrete - 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails J; ", ..,4•Water; Location -Test -Easement. Needed (Sketch)': 4. Wood Awn.; Posts_Beams-Rftrs.-Connec.- Shthg.-Rfg.-Bracing :; ' 5. Electric ity;:Location=Clearances=Gend.-/ .TAmp-Concrete 't-fi. Gas; Location -Test ;Wrap::/ / L',ft.".; •, •"; /" Nat:.or/ /''L''ft./ . /"LPG 5: -Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures. 6: Carports; Windows -Doors - T Utility Clearance a - T Elec. 8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses 9 . Siding; Nailing -Veneer -Stucco -Mesh - . r. Ca"rd-131" "' Date' - Card -131, . Date'.... 10. Roof; Shthg=Roofing- Card 131 _ :."` •' Date : ; = . Card781 , , ' . _.:Date .. • : " -� ` " 11. Ext.; Steps -Doors -Landings Date' MOSILEHOME;INSTALLATION (Plans) .OK except #'s .' Zoning -Requirements -Setbacks -Easements '. Card -131 Date Card -131 Date 2."Footings; Size -Spacing -Marriage; Line. Card -131 Date Card -131 Date 3.'Gas; MH Test-Demand;Valve-Connector , "Electricity; MH Test -Crossovers -Breakers -Clearances" ; Date POOLS (Plans) OK.except #'s' 5. "Drain; MH Test -Fall -Flex Connector 1. Setbacks -Easements 6. Water; MH Test -Regulator -,Connector 2. Soils; Compaction -Structure Stability .7. Water and Sewer. Connected -C/O, to Grade -HD Approval 3. Pool Structure; Steel7Connections-Thi6kness- Dead Men -Lining :. 8.. Gas.and,.Electricity Tagged .: _"• .' . ;r ; "_ 9. Exits; Insp.-Sketch ` ' ;; 4. Elec.; `Receptacles and Lighting, Distances-GFI 10. Cert, of Occupancy. . :'' ". 5. Elec.;. Pool. Lighting; 15 volts=GFI . - 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.;Grounding; Equip. w/5' -circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit Card -131": Date -... , Card -131_'. Date Card -131 '.Date, Card -B1 Date 9. Health Department Approval - '• 10. Plumb.; Cir. Test -Water Supply Test ` ± Card -131 Date Card -B1 Date Card -131 Date, Card -131 Date = OKE - = Noot"A plicable _ RESIDENTIAL (Single and Duplex)- = Not Ready Date i. ;' ,UND LOO ` Piens OK exce t,.#'s Date. IFRAMIINGContinued) Veto Hangers -Post Caps-Anchors=Connectors g.' in; Soils-Steel-Elec. Grnd.-/ P' Ftg. DepthCln .Joist-Rftr. Ties- Puri in -Roof Brad. -Tru hthng.-Rfng. tg., Garage; Soils -Steel-/ /" Ftg. Depth . ireplace Ties or Typ : A Flue -Fireplace T t 4. Ft ., ,Por ' s & cks; Soils -Steel-/ /"Ftg. Depth . Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles to ll ; Steel-Blockouts-Wrapped Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions . e s, Garage; Steel -BI kouts-Wrapped age Fire- Protection 'Framing . ab; Steel -Wrapped erty Line Firewall & Openings 8. Piers -Fireplace Ftg.-Steel Doors -One T -Check Garage -3rd story: 2 exits 9. D.W.V.; fall -Fittings -Test -2 way C/O -Sewer, Test ''527Stxrrs; Width-Headroom-Rise-Run=Lending-Fine. Protection 10. Gas Pipe; Size -Anchors od. on Roof Overhang -Attic Vents -Rafter Outriggers , 11. -Water Pipe; Test -Anchors -Regulator -Service Test. 54. Siding-Nailing—,Veneer 12. Electric; Underground . Stucc -Dr reed -Fd. Vents-Underflr. Access`. 13. Plenums &Ducts; Clearance-Material-Supprt-Ins. 56. Gla g,Area-Glass'Protection-Skylights-Plastic' 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 57. Ke • Walls; Nailing -Bolts 15. Insulation wiulation-Waft-Clg. 5 nfiltration- alts-Wndws Card -131 Date 6 Card -B1 .. Date j Card-B1DateL4110 Card -131. Date Card -B1 Dat�ard=1' Date. Card -131 Date Card=B1 - Date Date PLUMBING Permit OK except #'s .- , - 16:)Nater Ht. Vent -Access -Combustion Air, Date Plans OK except #'s. ' ater Pipe;.Test & Anchors -Nail Protection, Ext taps -Door & Sidelight, Protection -Landis s L -TIT. D.W.V.; Test-Fttngs & Anchors -Nail Protection ryeke Detector hower Pan; Test, First Floor-Tub:Access 1 urnace; Vents -Clearance -Comb. Air -Connector - F In arage; Above -Floor -Ducts -Meeh. Protection 20. Test Tub & Shower, 2nd Floor -Tub Access i Lgl as Pipe; Size-& Anchors Broom Exiting . G.F.I. & Bath Fixtures &Tub Access -Spa .: Iec..Trim.& Subpanel; Breaker Sizes -Labels. Card -B1 Date Card -B1 ' Date irs &Rails Card -81 Date Card -81 Date place or Stove; Clearances -Hearth _ • Etc. Outlets at Wood Panel; int. & Ext. Date ELEC ICAL Permit OK 'except #'s xture & Transformer Clearance -Ins. Protection , K►t. Fixt. & Appliance; Grnd. -Air Gap -Cooking Clearance - Iec. Receptacles, Spacing -Lights & Switches at Doors . F ec. Outlets & Receptacles at Kit. Counter Boxes &.No. of Conductors -Stapled 'WGarage Fire Door; Swing -Landing -Closer mex Installed Close to Edge of'Studs & C.J. . A.C. Duct in Gara e -Damper uip. Ground made up w/Mach. Fasteners -Bond Gas & Water r. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor -Meeh. Protection .Appliance Circuits in Kitchen & Conductor Size /7�Ib., Elec. & Mach. Equip. Listed for Location Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / /ga. gAi-or Al 7 Iec. Receptacles in Garage; (G.F.I.) Protec. W. Range Circ. / / ga.. Cu or Al -Oven Circ. t / ga. Cu or Al, jasulated Neutral Yes No IS -Foam -Looked in Attic ❑ Yes --'Guard Rails & Deck Construction -Post Caps Service -Riser Conductors & Ground -Main Disconnect a-78:-Pdn. Vents' & Crawl Hole Door=Dralnage & Wood -Earth Clearance Looked under Floor` O Yes Equip. Clearances Panels -Motors -Meeh. Equip. Clothes Closet Light -Shower Light -Spa Light 79:,Following instld.; Drive es ❑ No; Walks . A-YA ❑ No; Pljonters ❑ Yes &_1146 tucco; Brown -Finish Card -B1 Date Card -131 Date AtA.C. Unit; Disconnect, Electrical, Plumbing Q 2 Vents Above -Roof; Plbg.-Appliance-Firepl.-Clearance to Openings. Card -131 Date Card -131 Date Date. IPECHANICAL.(Permit) OK except #'s -• &--Water Well; Disconnect, Electrical, Plumbing ._Q: Ducts Insulation & Support . xterior Eleb. Trim; G.F.I. Receptacle -Underground e t Fan; Exhaustabove insulation qU Wgtilation throughout House ndensate Drain & Overflow; Size & Grade. A -111 -loss Protection Fugnace-Vent; Access -Comb. Air -Return Air, Vent-115.outlet r ections from,Previoug Inpections t7eAttic Access & Platform if Furnace in Attic 88: t=Meters Tagged; -Electric - Sf f JKWater & Sewer Connected -C/O to Grad&HY Approval nergy Compliance Certificate -Other Certificates; Card -61 Date Card -131 Date .Card -B1 Date Card -131 Date Card -:B1 Date Card -131 Date Date F NG Plans OK except #'s Card -B1 Date 'Card -B1 Date Ste, Proper Material & Anchors Card -B1 Date Card -B1 Date Wal s Studs -Nailing, Spacing & Bracing—Plates-Sound Comments at Final: . 4 Baring Walls over Girders & Floor Nailing raft Stop in Walls (rat,proof) 1 e, Stops; Furred Ceilings -Stairs -Chases -Tub Bader & Beam -Size & Bearing (NOTE: An entry must be made each time you.visit lob site) - c WE COUNTY ,OF BUTTE DEPARTMENT OF PUBLIC WORKS " Noi : 7 County Center Drive,- Oroville. California 95965 : Telephone 916/538 7541 x APPLICATION AND `I?ERMIT: '. ASSESSOR P RCEL.'NU R „ -ZONING A5K`` L '•- ' BUILDING PERMIT OWNER - _ =TELEPHONE- SO. FT.. OCC. BUILDING VALUATION , 10 OWNER' MAI NG ADDRESS-- /n"�"- .. _ 44766 CONTRACTOR'S NAME - TEL PHONE •, _ - , {ONTRACTOR'S MAI LLN GSA D RESS `. - Fireplace GONS.T••UC TI "ENDER,:. - - - , / UNKNOWNValuation Total, a Filing'Fe.e ,, - 10:00 LENDER'S MAI ING ADDRESS Permit - Fee .. $ ARCHITECT -.OR ENGINEER - - L CENSE No,' Plan Checking Fee - .A$.. Energy. Plan Checking F@@' y AR CHI TECTIO,R-ENGINEER'S MAILING A-DDRESS b s - . •t,' •Penalty $ , B.UILDING ADDRES5•=`. .. - - Permit f@@, - $ � PLUMBING PERMIT Filing Fee '• 10.00 - ° Z Each'Teap" 2.00 0? r' 'PAR'CEL Sol ar or heat pumpwater. heater 20:00 LOT NO. SUBDIVISION NAME -p .; 1`614 c l60 OR4 � � MAP', ��— Z� Water piping � � -. � � 5.00 Each•gas water heater or vent, 5.00. , 'USE OF STRUCTURE SF Duplex0 MobilehomeQ , Other • SPECIFY `Gas. piping system 1 - 5 outlets 5.00 Building sewer 5.Q0 Mobile Home S G W 0.00 ea. TYPE OF WORK New Add ition❑ Re ode Cl Utilities El Installation❑ Other 0 DescLLriibe: work: bP /g%% Permit Fee $ Contractor - ELECTRICAL PERMIT ' Filing Fee. 10.00 - Main service 600v OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'.L 100 AMP'. ,-2.50 - CONTRACTORS.LICENSE LAW I declare under penalty of perjury (check.one): . �_ I. am licensed under provisions of Chapt. 9, Div. 3, of. the. Business and .Profes Bions. Code/and my license. is' in,full fo/ryce and effect.. GGi rrl - R` 1 - - License No.• ' Classification -ii-.as the owner, or my employees with wages as their sole compen-: sation,,.wil1. do•tbe work, and the structure is not 'int.ended or offered ,for sale. ;(Sec. 7044) k Q , I,' as the owner, am 'exclusively contracting ,with .licensed .contract- ors. (Sec. 7944) Q 1 am exempt `under Sec. Business and Professions ,Code: for this reason NEW CONST. f DWELLING OC P , OR ADONS.- ACC. B.LDGS. h2sgft ZZ NEW CONSTR ULTLOUTE-TL NON.RESID (BRANCH. CIRC ITS' 2.50 ea. , _ POWER APPARATUS tr (SINGLE OUTLET CIR. '� Ex. OCcup(OUTLETS OR FIXTURES 5AL030 nALa3o UNS. OR \ Ex. Occup. our OUTLETS P(RESIOJ EA.) 2.00 Temporary service, 10.00 Mobile Home Facilities 15.00 ' Misc. Wiring' 15.00 Permit Fee $ Q. Contractor -WORKMEN'S COMPENSATION. INSURANCE ` I declare under penalty of perjury. (check one): Q 'The permit is for $100.00 (valuation) or less. I have placed on file with the County of 'Butte Building Department " . . a Certificate'of-Workmen's:Compensation -Insurance or -a Certificate of Consent to Self -Insure., , I ` shall hot -employ any person "in any manner so as to become'.subject, .tto the W. C. laws of California. Notice'to Applicant: If'after making this statement, should you become subject to the W. C. provisions of the Labor;Code, you -must forthwith comply with such' -provisions orthis.permit shall' be deemed revoked. MECHANICAL PERMIT Filing Fee -10.00 Heating G! Cooling I. Hood '' 3.00 JLA Ventilation . •1" ,Permit Fee $ ' Contractor I certify .that I have read this application and state .that the above information" i.s.correct.,lh,agree to comply to all County Ordinances and State" Laws relating to buiIdingconstruction, and hereby authorize representatives'of the Countyot Butte to enter upon the above-mentioned property for inspection purposes: „ 1 also agree to save;.indemnify and.keep harmless•�the County of Butte against' all,,.liabilities, judgments; costs, and. expenses which may:'in any way accrue "against'sald County inconsequence of, the granting of this' permi `.' `" c► `� X Date 3 v Signature'of. pliconf;= Owne' Contractor iC. Agent ❑ An OSHA permit is-4quired for ezcovctions over 5'0''' deep.dnd demolition or construct -"IR ion,of structures over'3 stories in height. Mobile Home Installation Fee $ " Energy Inspection Fee $ TOTAL.PERMIT FEE $ OccUP:J CONaT.TYPE - FU ARCS D. N1.D lana Thi's ,permit is hereby: is ed under sions of the Butte County..Code and/_or work 'ndicated abOVe :fOr which CeTOR OF PUBLIC ' By - . PERMIT EXPIRES: Date .the applicable provi- resolutions to do . fees. have :been paid. WORKS. Date v Receipt Na « !� ' D.P.W.. YELLOW=ASSESSOR, PINK•INSPECTO, GOLDENROD:APPLICANT. WHIT[ R r y I: kt _.t:.-..ra._ +.� r.. _,.n` •- r- i i i rth., g, > a s t a T Y s c 1` y !.1 'i-°��5fs. �F.- _i ° + k �"fr .sem r, `a .#stn ''t r$ a . a , t : � #, r - r ' ur 'r.aa i 4r t , i ? F t.1 4 ,, S', P ? F 4 h. nr ! t l v y•.. vI i i _ ii t ~ `1 1� . % de ar j„} rr C•`. ,i t t 3 'c. t: ' T. r si r ,i ,. 1• r' i't r - �. 11 I., -fit r` r t' a t. F.- . !•t. 1?' i s e. 1 I S7'.: �' � r . ++ ''s� —* 7 r S r L x, 9 s 1. 1 •,✓J av, - '4 t f _ :Zr A 's-- F,, e 1 Lai �i�, S e '7'i.d,i i�Q +*rY 1 t ln•Yi. ! 7 � ., w, ,�' _a., .y p�,.. .� ._ �` ii•'"'A. "yv .� • 1° '! k+ ;fir rid t — ' i"y�� r s ?. is s k}•; .t�. �'� t• ,t t r .... r K t Y 6 Sr �'i 'W,r' r i( , f , ti t.. 7 a-" ,.. ;.' :t 5.+ t _ ` - - a �F ;s•°r,Sr. tl` C1 +:i { Y t f , A q1f .r,.� J ..r a- .+\ _•J , 'C44 r„�r.. f. 7 s / � I ,r'. - t li y , 1 ,{ r e, t �.: .0- ,r r - 3 ,., F 1. f M l ! ' aG - '' {,..:.i4 t' 4 u tt ,+ ;i' #Y at 4 * CJ f t , , r J ' Ifs. `t ri Ys j iJ Y t; r P ; t i } :i s ..*k � ' ,f'� y.. - - , o f i-.a y , 'JI I y, % t,r a - r t '. 4`i. i 4 'P'ti ; • ti - ". i ` .'I, +.I .. f-"`. .-t c. . k I �, S a.r w y -r.:. i _ s x ;, b . r t s I r, k ,I J k .. , h r �, ° 3 s.I f , r sa r I,'i 1 } �. 8 b �: a v r t 't ;� `f r 9 �rte�9 ,iJ t ° it r. Q . 3.� ' Ll { r r +c i A � t rY, ' ,.� . 1 •moi -f �' �r � ..,-.t '4 .:J - s4; * ,; F } r - ' h iT ,T - f ,Cr` 4 r 2� iF ' a C,r r 7 yr4F\ `} , i v J s �� � h -.� :, y- 3 r 2 } v t:. — i 1 ." ', r _ ! IG +41. r - - !r .r- t , y t I .{ rf ,, i sk : t -� F t 2 � . ;�+ �r 2. Y. -� ..3. .r`:. w. .,jt ., t- Sh4 P }it) t ) t ` y ri'� , ' s -K }� ',r do I ..0 ' r e * i; n, c ,, t o v i u is it 1 i, } S y rf ti h a'. r > '7 J. i'„h Y ,� t t s t' - rt L ,? k i rt.- � k F-F -l'' I 1 d 4�r� y r - r6 y t I '',�. Y yr .. W .k 11 t , r'. ,lr t. k: ; ilx t r - � 4, � +rc 5 : It ,i r -'t -% s ! -,> c ) � r { -t. a , + . c r I YL 7fJ t: t,: f i ir„. a >(Tt x'+i1 r � -k :-r '.. r,, T —.. 1 - r a x �. :ttr n., ?, �, I:. .s I o F rs rh y ,.r a e :� } T r14� lFt t � .1t °,r lid, i . c 1. ._ "t :v :;I K c. g I; I. r i r r•� , i. 1 S N L....1 11 I J1. W ) 1 1-.1 , z j + l i r ,Y x -.�- I r :'•itl , y� ~ t K h/ ! r y i .. r 1 f _ j Y •� r+ `41 -! `J 1.�,1V j' f i.'f r' ,VI i'. k �•.'4 -: ' ) \- ti r v t _- 3 I'.) . s a e 9�. "�, �. ". di r Ti •;� r� - ` � I y+ _ � ,-. �, # . � .71 t..3 r�• t ,» _ r .,. .- fit ^r7 1 rf * t I r' s � „• �-1 -i 5. t F ,,.I. y t , -, c^ 4 _ '»�11 . a. -4 ,Ja i T h ar f 2, .. f e» tS.T-, . r !'s �t ,.t 4 •'R. cs" i '/ .`* .� t7t \1; .r' " '', .{s ..,� J , ., t t i,F 4i' . r x - I - „r tai # ,. 4'a: V e-- . jt: o NI t' ;'� " r we f. ti,i t .`c i _e c '.i " 4\= , .r---' „� :-Y ! 1. 4 .. } �, <� � ti > ^ ° t- c a pt t' :.. t� � s � � 11 r ; ... L,. a : •rte � 4 � ' I � L } . f r. y ' �' _' t -. 1 _ `2 t{., -F 2 - "� d yam. ; i + t� "' - + ?. f .*tea '�-, "r• ` r- ,.,. tt:e F z-14 S 'ls T-i Y .1. � f Z, 1'c . v. [ 'i r Y ,1 ��3 ZF X'..1. rr ,r. r ry i 4. * , �-v �`t'�� 'plc - _ _r >s`,yw :a, J i r n - `i; 1` Y r t 1 r t 't t Y' 1 `, 4� � ) a i s < f T `h: r t•'r `it y,'. i''tk,. P `, �. f ?y' r^•r ,.S IK i� 1 •t ty'� trr ' Ik `d I ; r4 f .. ,,,," I Art '. o ti s.. -.` � ,. k � ,a. ;" aE �l ;� ass. :a .I i� - i to 1' , .�. f4 y 41 r ,,1,, i r I {)J'J?`': ,; t :"N•r��,s,,3. >r �Y�,, Y, �. A, .I SS > �,� V' wr -', ....A.EZx,r-, ., s...;i a. ' Mh:n duh I x7Al•Lc .Yr.. _:%--;fis >.X Gyi.Jt J ,�, N, •. ', J^S, f. , . P'Krtl!Nb Y>.'T... w„' iY.., _ _ ....... .. n:. ...0 : ' ..-'. COUNTY OF BUTTE - DEPARTMENT�OF PUBLIC WORKS - BUILDING rDIVISION 7 COUNTY CENTER DRIVE - OROVILLE CALIFORNIA.95965 '- TELEPHONE: 91:6/534-4541 PERMIT APPLIJTIO DATA SHEET /� ,/ Permit No. OWNER �l y— X/ %7i�C/� � .., A. P. No. Proposed Building Use /U-Sra Building Inspector 6� Date S I " At time of permit application, I was advised the following data must be submitted prior to permit processing andlor issuance: DATE RECEIVED APPROVED 1. All items have been submitted. . . . . . . . . . 33.. Plot plans in duplicate. /triplicate, signed by preparer of plans. . Complete plans in duplicate./triplicate, signed by preparer of plans. 4. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. _ "Fees g �6. CUSD Paid" Stamp on Floor Plan . . . 7 Statement of Intent for Non -Heated and AC Buildings. 4 8. Fees of $ . . . . . . , . Letter of signature authorizatio C� -. Sanitation approval from -�� Health Dept. 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. . . . q ° 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to ownerE, Mail 'to owner ❑ ) _15. Improvements may be required. 16. Mobilehome Installation Data. . . . . . . . ' ' 17. Pre-Inspec. request to (Date) Pre -Inspection for Required. Building Inspector ��8. Recorded copy of Agricultural Acknowledgment Statement. _19. Driveway Permit. Y 20. Plot plan approval from city of f :` •'' 21. 22. ., ry When you issue the permit, process as follows: I Mail to owner, Mai to contractor. Telephone and hold for pickup at office, Deliver w/inspector,. Other '� e • '' Applicant �.1,11M cam. ��`�' Date �� • Copy of plans sent Health Dept., Fire Dept., Other Date The following data must be submitted prior to permit issuance: (Circle new item not checked ab9ye). 1. Index permit for above,items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data. by—phone---mal counter b"y date Contractor, designer, owner, was advised of above required data by_phone—mal l_counter by date Plans checked by Copy—DPW Date Plans approved by Sets of plans on hold in File cabinet AP folder 10:00 a.m. - 3:00 p.m. P ^.:ICJ r`1.i*. - .♦4 _ • l � 7 .. �" I..i .1.4 � ., L:4lr' .. i r TO: Building Department. FROM: Environmental Health, Chico SUBJECT.: Sanitation Clearance d✓� tom, � -?zr�, Owner Location AP Plann,approved for; sewage. disposal water supply- Hold final for: water supply Final clearance O:K, for: _ water supply Clearance for bedroom mobile me. Other • 1 Note*** Sanitarian Date RESIDENTIAL PLAN CHECKING GUIDE (S.F., DUPLEX & MISC. ONLY) 7/85 Bldg. Permit # 16q OWNER `� I�� %Z!C�� � A.P. # GENERAL Y„,Zoning requirements: (sideyards Valuation. ans signed by designer. ,�tlergy Design and Compliance. Existing violations on property. PLOT PLAN and number of permitted living units). b� complete parcel. .size and dimensions. 2o.01 -Setbacks, sideyards, easements, etc. �3her buildings or structures. �ading, fills, drainage.. ood hazard. 6! Special conditions on creation map or compliance document. FLOOR PLAN ]si omplete to scale plan with dimensions. quired windows for light and ventilation (Sec.,1205). � Required windows for second exit (Sec. 1204). �lights (Chapter 34 & Sec:.. 5207). Lyman impact glass (Sec. 5406). 6/wired room sizes, ceiling heights (Sec. 1207).. Z� G.F.C.I.'s in baths, garage and exterior outlets (Article 210-8). 80e0oright fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment.. Locations of water heater, heating and cooling equipment, other electrical or gas �uipment, and plumbing fixtures. 18/rage firewall, door size, and closer (Sec..503(d)(3)). 1 1 - 3'0” exterior exit door (Sec. 3304(e)). 1Qi�egkesa and wood stove location. 13,/Smoke detectors (Sec. 1210). STRUCTURAL DETAILS Im ,Foundation plan complete enough;Ao construct building. � oor construction details complete enough:to construct building. evations and wall construction details complete enough to construct building. of construction details complete enough to construct building: eplace construction details and calcs if necessary. Sufficient data and details to satisfy energy requirements (State Law) (Form 1). MISCE LLANEOUS ITEMS TO LOOK OUT FOR :5:osure I plywood on exposed locations and overhangs. Jrairway details: landings, rise and run, head clearance, handrails (Sec.. 3306). ardrail details (Sec. 1711 & 3306(j)). 4,-'-B ck or -stone veneer (Chapter 30). 5/.�&terior plaster - weep screeds (Sec. 4706). �! oper roof pitch for roof covering (Chapter 32). Rafter ties or bearing ridge beam. RESIDENTIAL PLAN CHECKING GUIDE (CONT'D) 7/85 MISC ELLANEOUS ITEMS TO LOOK OUT FOR (CONT'D) �! rage door or porch header sizes. Adequate bracing. .19 ­T ving area over garage - complete 1-hour separation required on garage side including supporting walls and posts, etc. o exits on three-story dwellings (Sec. 3303 & see Mezannines 1716). A is access and ventilation (Sec. 3205). V;FOrfloor access and ventilation (Sec. 2516). JJ-eod stoves, clearances, alcoves & 1-hour shafts. 70. Combustion air for fuel burning appliances. poise requirements on duplexes. A+. obe soils - special foundation design. -M.77Tetaining walls requiring design. usual shape, size or split level house requiring lateral design. f ZONE 11?aDla ]-7a: Gelling loculation -Table 3-7.: South-Faein Clazin 'Pts kTable '3-10: Shading Coefficient -Points ! POINTS ' OWNER' c Fi/IIJJ,,'' :- . : . Points .I . Orten-: PERMIT y ASSIGNED ACTUAL . ;:: IF 1 Glasing .Type I-: 1 0-3:i. V to . I 6 4`xp : 1< value of Insulation• I Yoinb I I '. ,1 6.3' (:, -Total I I 1 $IAB INSULATION ' J I I I ': ' I ` I: of I sngl, Dbl. Tcpi . ' .83 up, I.. _ I South --:;1-'0. 1, 3.2 1:6.4 1,3:0 1:9.6 I: I to; '1,to • I- to . I to I up Floor I °(0 - I (u.- {. (D - 1 '2 P.AISED FLOOR -' R-19 +1 1 +2 1 ,+2 ', +3. -1 19 ,1 0 I 0 1, 0-1 `.'0 1. 0 1.10) I0':65) 1 0:414 { "o :1 1 i =2 I v2..I ' =] �.. ( 22 1 2' 1 West •' 1 I-' ' 1 olnisA oints I ointsl T. CEhLING R 30 ''�- I 30" ( I o" +! +9' +g a , : y 4 WALL R-19 " 0 I +1 I +3 ( 1 +2 '- I ie 49 -.0' 1 0A 0 1 .0.1 , >0, 6 up t� o lQ s �� +2 I .:.+2 1 +2 1 3.6 I -1 . I '�tf- ' I 0' PrP 3 3 "r � ` 3 'I '6 I 12 I h5 83 up .1 3.7- 5.2 L :' -4 1 . -2 1 -2 1_ L. S 3 'I 5. NORTH GLAZING 2.4-3 67 -.� I' 7nc.11a-. I -Value'-of lnsv/eC1on'I': Skylight I 1 '1, ..8 1 1.6 1 3:'2' 6.5 I -6 I -i. { _3 ` g� O 0-12- I 1: -1.'8-'8:9 6 EAST GLAZING 2 5-3 bry =7 .� 0 i. 1 1 `3 I 6 :1 -' 1 0 1 I' -10 {.. -9 I ` 7- ',-'SOUTHL GLAZING. '. 1 6-3.67, I Table. 3-4a.. Wall Insulation Pointe .-13 . `.'I' 10:1-I1:S 1 :.-11 I -0-- L:-11_ , I ` -► p .. 1 Il value of' Inaulacion 1 I 11.,6-13.0 L' -21 1 -16' 1 =14 ^'I I, 13.1-14.5 I I 8 ,WEST GLAZING 2.9-6%- 3 `T�- 7 :'. .I .Pointe :I . -25 ,-19. -16r. `1.14 ' I 1 1 6-16.0 1' -23 I 22-6' 1 '.9 1 9 SKYLIGIIT '­' t I 1'.4-,2.4;1_. .+1:--'l 10 SHADING :(Exclude -Overhang) 1 .- I 19._: 1 . Table 3 8. 'Went-Faein-Clazln Pts.- 1'' -3 1 .,,tabl'e 3 12'..% no6abla-Iniulailoa - 7. EAST 6.6- I ;' 1 30 1 +3_ I total Olaileg type I SOUTH. 19:-.42' �j• �- I 1_: x eE 1 .Sngl, Dbl, Trpl, -' WEST = 13'- 36 C►_ Table .3-S. North Fac1e' Glatin Pts {; Floor. .I Aree I, (u ' `I (U... I (u . I . J 1.10).1 0.6550.41).1. ,4 SKYLIGHT > 37.- '57. 1 =5 I :Z it 1 I' Glating Type 1 . I .1 I ointa I olnes I ointsl :- 11 HORIZONTAL SOUTH OVERHANG 2 �. �� O - `':li - 1 • =S • 1 -5 '`1 'Af I Total ', I• I of O 'to A'.3 •i �6. +6 1: .+5 I +6 I '+6,•>I .: 4a NONE '�- 1 -8` 1 -4 -.2 :Sngl,; I Yloor 1 U - I Obl, , Trpl, 1 U'- 1 U -r I I 2.7- 2.8 I 0 I +2,: I +3 I_. 12 MOYAHLE INSULATION -5 3 -2 :h_=1 1 . ; 1 - 8. -.12 1' A ea I'Ot66 L.0:42 1',0:41'.1 I 2.9- 3.6 - . 1 -3 .{ 0 .I +1 5�0 �� " 1 ) 1.30 10.65 1-dovn I I' '3:7= 4:2 I,' I. 0 13 �.' INFILTRATION':(Standard. 0){Tight +12) 'I ; r2 L 1 4 -13-1'' -8 -5 _2 .I r .. 1.4 " THERttAL:;MA55 I `S:7- 6:2']+,---:j9 I . -16 3= 2.3 I +1 - .f� . 1 +2 :1 1 - h ',3'iT6'T - - - to g ; 1-' 1 7 8- .8.7 1' _ =15 , 4- 2. 3.6 1 -2 .+2 I 0 +1 1 1 5.7- 6.2 1. 1 6.3- 6.9 I � -13" I '1 -7 I ' 15 GAS FURNACE (SE). 7,1'-767. �"' 1, '3'.7- 4.8.,1 ` =4 I -2 1 • -1 I ' f -'7,0- 7.6 1', . -15. -10.: -18 I -12 1 1 ' 7 57 97. :�- s 16 HEAT PUt (EER)!,; _ �,�_ I 1 4.9= 6.1 I -7.1 6.2-'7.3 'I ' -9.., I 1 -4 rr 3 1' 1 7.7- 8.2 I 8,.3- 8.8-1,-22 .-9 -2J 1,•r14:. -16.'1 T. 17 DUAL PACK.(SE,'.SEER) 8 0-_8 3/7T-76% 8•• '�'- .7:4-.8.2'I', -12.1: I 8:3-.9.7, I -14- I -8 1-"-7I,"-lg- l0 : -8 I: 0,6-10.1-{" .I • ,-13' I r15 _ :. WOOD" STOVE • ' 4 ' I 9:8-10.8':{ . -17*-10 1 10.9-12.0'.I -19 '1 ,.1 I -12 I -1 1. 10.2-11.0 1 ' .=27 I -20• I -16 1 -29 1 -23 1 -17' -1 - ATER. 40 12.L-13.2 1 -22 J .=14 ,`I =16 'I -13 I' 1 11.1-11.8 1 .'-35 i -26 1 -21 I . 111.9-12.7 ( 738 I -29. 1.-24' ,WATERY :; r C =< "• . -25 „1.13.3-i4a.l, -za: I, ' 1 14:6-1 5.3 :-ls: -1, -1s : I . 1 12.8-13.5•-62 1 -32'._1`.-27 , =66` 1'-29 1 -8.3- 8.8' 1 ..-28 1 .-22" -.-3z;:T0L-17ATTIC 1, -so =387" 1.` 4.4-15:2 : 1 '• OTHER .I . Orten-: I I Flooe Area . .•.tation I• I ' I I-: 1 0-3:i. V to . I 6 4`xp : •' J.. I '. ,1 6.3' I 01-.1t I 0.,.1 +l, I +2,,. 1 .20 .36 .1 . 0 I 3 7-.82. I o.' I 0' 1' I 0 1 0 ' .83 up, I.. 1 0 . 11 f. I r2 I South --:;1-'0. 1, 3.2 1:6.4 1,3:0 1:9.6 I: I to; '1,to • I- to . I to I up I 1 3.1'1 6.3:1-7.9 1 9:5 1' - I +1 1 +2 1 ,+2 ', +3. • .19-.4'2 :I ,1 0 I 0 1, 0-1 `.'0 1. 0 I., ;43-.66,. I "o :1 1 i =2 I v2..I ' =] �.. -1 ' -2`1 "-4 1.,--;4 J; 6' West •' 1 .1.1 1.6 1 3.2 1 6.4 1 9.0 be7-2"teed. FoorPointsF to .,1 to. I,to 1 -to 1 up 1 F 1.5"I 3 1 1;6.3 1 7 '9 1= I."• 1 a{ . 0-.121 1 0 I +1 I +3 .13 .36 i. -.0' 1 0A 0 1 .0.1 , >0, .37-.57, I 0 I, 1 1 -3 1 6 I =7 Area'. : 1 1. L0)' .:0.65).1 3 'I '6 I 12 I h5 83 up .1 -2:1 4 f 81 16 I` .0:65 I .dovn-.I (`0.6, 1, 0 : I r2 3 '' 1 I' 7nc.11a-. I -Value'-of lnsv/eC1on'I': Skylight I 1 '1, ..8 1 1.6 1 3:'2' I to. to' 1-,t6- I. to 1 to to, I 7' 1'151 J:1 13915:2 0-12- I 0 i;+1 w I +3 I +6 1.. +7 .13-.36 :_ I' 0 I 0 1"0 1 :0:;1. 0 37 :57 1 0 i. 1 1 `3 I 6 :1 -' .58-.82 +7 .{ . I +4. ".83'.up_ 1 -2 •Ir 4 1: ,-e . 1, -16 1;=-20 '• OTHER :> `I " 1 1 1 I ,Table 3-11.• Borizontal South 4 - Overhanq::Polnts Table 3-9.' Sk 11oht.Polnta outA Gl'azlog _. -TOTAL' `OINrS,. + " Table -3-6.. Eait-Facin Clazin Pts. I Length Out` I Area I ::of Floor 1? r. GlaiinB'TYPe I L` C1azing-Typ� 1 1''Eom Wall' 1 I" I .:Y Total ..1, :, -1 3 .1. .: Et -- 1 ., 'Dbl,• ..-x. of gl, Sn Floor', o Dbl;,-: Trpl; L I 0=6 3 1 6 4 up' 1 _ able 3-1. be7-2"teed. FoorPointsF ( Z. ;"1 Sngl., Trpl; Floor: ', I (U - ' I..(U. (U - I _ I' I. -. I - Area. 1 0.66- I U I 0 42= 1 0 4171-1 :. 0 0 -2} - Area'. : 1 1. L0)' .:0.65).1 :0.4i);I _ :L. - I' 1:10 I` .0:65 I .dovn-.I (`0.6, 1, 0 : I r2 3 '' 1 I' 7nc.11a-. I -Value'-of lnsv/eC1on'I': 1 A Value of ' 1 ." I" . �1 oin'ts.'1 points 1 oirital . I 1'.,1 - 1.9. -1 -2 1 1 { tiue I I 1 Insul'etion.. I Pointe+ +7 .{ . I +4. r4' I +4 I I :up to 1.3 I 1' I 1 4-.2.2 1 -3 I C I--. 0 1 12.0 up I 0 I 0 I ^ I' Depth. I i..:_' I up to 1.3 +3 -2 Inches 0-2 1'3-4• I 3-6, L 7+-1 :.,. I 1'.4-,2.4;1_. .+1:--'l +2 1 '.+2 1 .- 1 2:3- 2:8 I : -6_ I -4.: 1'' -3 1 .,,tabl'e 3 12'..% no6abla-Iniulailoa - ,1 I'- , ,:'. Delov,.3 ,;. I ;' I I 2' S '7:6 1, -2 ,i o I Q '_l I 1 -z 9-}3.6 I -7> I -6 I rs:1 Poinca 1 3... 4:: 1 8 1 I' 3'. 7- 4`6 1 =5 I :Z it 1..:1 : 3.7-;4':2 I -11•. 'ti I =8', , =10' I 6`.,I O - `':li - 1 • =S • 1 -5 '`1 'Af 1' S -'7 -6 { ( ,4.7- 5'.6 1 -8` 1 -4 i '3 1 1• •'4`.3-, 5.0 1 14 , I - i =8. 1, 1, Moveable_..Insulatloa -5 3 -2 :h_=1 1 . ; 1 - 8. -.12 ,i 1 •.. -4'. 1 I S 7- 6:7.1. -10 I : =6 1 -5 •1 I :' S.1- 5.6 I '-16 I r12 I Area,' I of Floor P-Pelnts. 1. '" ,.1-. 1.16 =x.19.1 -5 i -2 I -1 `1 0 1 1 13 - 'I ; r2 L I 6 8-:7.7 -13-1'' -8 I , -7' 'I I `S:7- 6:2']+,---:j9 I . -16 I • I: 20. } I S.'. I -1 1 ; 0 1 +1 1 1, - ) 0 ' 1-' 1 7 8- .8.7 1' _ =15 I . -10 1 `-Q . I I 6 3- 6.9 1' - .1 1 . -16 1 -17777. T -77r 1: ' -17 T I -10 1 1',7,.O- p.'6.1 . -24 I r4a,,., l -15 I I' y` 0 5 s I ' o 1` 9 '8 lli2 1' •.-z1 `11--15I' ' 1 -13 1 '7 7 ';8.2 I -26. 1 . -20:; 1' -17 ') I: . S 6 - 11 3 1 `+2 L , 11.9 12:7.1 . -25 1 -18 .-1 -13 1 1 -8.3- 8.8' 1 ..-28 1 .-22" , 1,. -19 1 --1 11-:6 - 17'-5 : : +4 1' 112.8-14.0 1 ' -23 ' I -21 . I, -18, .1 = 1 8:9- 9.3 1 .-31 I '-2f` I .-21 I I - 17.6-- 2] S .: } +6 -32 1 -24 I 20' I I 9.6-10.1. 1 : -37 • 1 ' 26 - ( 22 I b'• ZONE 11 TABLE 3-14 (ADAFTEO) INTEN,IOR IN MASS POINTS Tabla 3-13. Inffltzation Control Featvres Points �- --- 1 Control Features I Points I T- I I I Standard I 0 10.9 air changes per hr I -I I I I I Tight 1 +12 I I I 10.6 air changes per hr .1 I i I I Table 3-15. Cas Furn4ce Without Refrigeration Cooling Points 1TSeasonal Efficiency Points I I (SE), I I I' 1- I I I - 71---;4 --- -1- - 0- - I - - I 77 - 82 I +2 I I 83/ 88 I +4 I I .89 - 94 i +6 I I 95 up 1 +8 I I I I Table 3-16. Heat Pumo points I Energy Efficiency I Points 1 I Ratio (EEA) I A 1,50 I C I 7.5 - +3 3.0 - 8.3 +6 II1 8.4 - 3. +9 - 9/6 88 I+12 I 9.: 97..9 97 +18 1 1 •10.3 10.8 1 +21 1 I 10. - 11.5 I +24 1 1 6 - 12.3 1 +27 I I 2.4 - 13.2 I +30 I Table 3-17. Cas Furnace With Refrleeration Coollne Points IRefrigeracioal Gas Furnace I I Cooling 1 SE % I I -171-177-i83-18975-5-7 I 1 761 821 881 941 uIsI 1 8.0,- 8.3 1 01 +21 +41 +61 +8 1 I 1 +41 +61 +91+10 1 I 8.S - 9.2 1 +41 +61 +E1+101+12 1 1 9.1 - '-).7 1 +61 +81+101121+14 1 I 9.8 - 10.3 1 +314-101+121+1'41+16 1 110.4 - 10.9 1+10;+L2i+l+ 1161+15 I 111.0 - 11.6 1+121+151+161•+181+20 1 7/7/83 QS: FT. 1,000 I A / C D A 1,50 I C D A 2,000 B C D A / C D I A , B C D I A , I C 0 A , I C 0 I A . B C O A- 5,000AREA i 8 C `50 2 2 2 2 2 2 2 0 i 2 2 2 0 0 -0 0 0 0 0 0 -0_ 0 0, ,0 '.0 0 0 0 0 0 0 00 2 (00 and u I!i 0. 0 0 01 100. 4 4 4 2 2 2 2 2 2 2 2 2 2 2 2 0 2 2 +13 +17 +it +26 +30 . 0 +4. -4-7 +11 +15 1-19 +2 2 +26 1,20fr1,499 0 +3 +6 +9 +12 +15 +18 +21 1,500-1.999 0 +2 +5 +1 +9 +12 +14 +le 2.000 -?,999 0 +2 +3 +5 2 0 2 2 0 0 2 2 0 0 2 2 0 01 0 0 0 0 ISO 0 6" 6 6 ..4 4 4 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2' 2 '. 2 2' 2 2• ` 0 2 2 2 0 2 2 2 0 200 I I 6 t 6 6 4 2 4 4 4 2 4 4 2. 2 2 2 2 .. 2 2 .2 2 2 2 2 2- i 2 2 2 2 2 253 10 10 8 6 6 6 6 4 6 6 4 2 4 4 4 2 2 4 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 307 12 12 10 6 8 8 6 4 6 6 6 4 6 6 4 2 4 4 '4` 2 :' ,2 4 4 2 2 2 2 I 2 2 2 7 2. 7 2 I 350 14 14 12 8 10 IG 8 6 6 6 6. 4 6 6 6 2 6 _-Is_..4.�2-"'4-4""-1`­2-�4­ 4" 7""'2' -4"'-4-=2 ...7. 2 2 7 2 400 14 14 12 8 10 10 8 6 8 8 6 4 6 6 4 4 6 -2" - 6 4 2 4 4 4 2 4 4 4 2 4 4 I 2 4 4 2 $07 18 18 16 10 . 12 12 10 6 10 10 8 6 R 8 6 4 6 6 6 4' 6 6- '6 2 6 6 4 2 4 4 4 2 4 4 4 j 603 22 20 18 12 14 14 12 8 12 12 10 6 10 10 a 6 8 8 6 •, 4 8 E 6 4 "6 6 6 4 6 2 ( 6 6 4 2 773 24 24 20 14 18 16 •14 10 14 14 12 8 10 10 10 6 10 10 a 6 a B 6 - 4 8 6. 6 6 6 6 41 6 6 R 2 230 26 24 22 16 70 16 16 10 14 14 12 8 12 10 10 6 10 10 8 6 10 R 8 4 hee - 6 4 8 6 6 4 6 6 6 3 900 28 28 74 16 22 20 18 12 16 16 14 10 14 14 12 '8 12 12 10 6 10 10 3 �6 0 a '8 4 8 a 6 4 a a 6 c i L, 110 30 50 26 18 22 20 20 14 18 18 16 10 14 1/" 12 8 12 12 10 6 12 1 0 61 10 70 B 6 8 8 0 4 a i I,;OU .12 32 28 2O 24 24 22 14 20 20 18 10 16 16 14 8 if 11 12 88 1 6 10 10 10 6 in 10 9 6 '0 e 6 e 4 ! 1,200 34 32 30 22 26 26 22 16 22 20 18 12 18 18 14 10 14 14 LV -'S 14 12 12 8 '12 12 10 E 10 10 9 6 10 In a 6 ; 1,100 37 14 72 22 28 26 24 16 22 22 20 12 18 19 lE 10 14 8 14 !2 '12 8 12 12 10 6 12 t0 10 6 10 ;0 F. 6 -1.400 - - .34 --34 _32 24- 28 - 28 26 18 24 - 24 -20 -11 -20- 20 -18 1.2-' -18 - 16 -14 - 10- -14 14- -12- - 8 14 -14 -I2 -- 8 12- - 12 ; G C ; .0 10 11 5 1,100 I 76 31 74 24 30 70 26 18 24 24 22 14 22 2 18 12 18 is 16 10 16 16. 1.4- 8 14 14 12' a i7 12 to 61 77 17 1;. i 2,000 34 34 32 22 30 ..30 26. 18 26 22 16 22 22 20 14 20 20 18 12 18 iB 16 10 16 16 ii 61 1/ 14 12 e 8 I 2,507 I 74 34 3 2 30 30 26 18 26 26 24 16 24 24 22. 14 22 22 19 12 20 20 la Ir 19 15 16 "D i J,C00 34 32 70 22 - 30 30 26 i8 28 ''6 .24 16 l24 24 22 14 22 22 20 14I 3,500 32 32 30 20 30 30 36'. 1d 28 28 24 16 26 24 22 T4 1 '4 ',4 20, 14 ' 4.700 - - - 32 32 30 TO JO 30 26 18 78 26 24 if iS n 2:: 1F .I 4,500 f i 32 32 2a 20 1 30 37 26 1t j ib .^. . 2- ;E ; 2f 23 j IJ % . Al I . J•y- Lgncrete Slab: HC -8.93; R-.29; Factor -7.3 2. 3 7/4' Thick Common Brick: 11C-7.125; .R•.13; Factor -7.3 8 1. SV,Concrete Slab: HC -14.106; R-.458; F.ctor•7.1 C 1. 8- So11d Filled Block: HC•2o.63; R-1.93;. Factor•6.1 _ 2. 8• SOltd Filled Block With Both Sides Exposed To Conditioned Air. NOTE: Use all square footage directly exposed to conditioned air for Thermal'Mass Area: R HC -10.164; -.96�; Factor -6.1- D) 1• Thick Concrete/Tiler HC -2.55; R-.083; Factorr3.7 Table 3-19. Zonally Controlled Electric Resistance Space Heat lit Points I Points for this neaaurc v!11 Table 3-20. -Solar Water Heatin .With rag Backu Points be completed after the CEC I 1 has approved an Alternative I Component Package for ReSLstance 'I 1 Beat. Table 3-19. Active'Solar Space Hearing Yitn cas-Points I Net Solar Fraction I (NSF), Z �I 0- 6 1 0 7-1/ 1 +2 I 15 -/13 I +4 1 I 24 30 I +6 I - 39 I +8 1 1 0-47 1; +10 1 I 48 - 55 I +12 I I 56 - 63 I +14 I 64 - 71 1 +18 1 I 72 up I I +20 I I I ;wood stove 033 points'(no back up) casablanca fan + 1.point M.ul[3CamiT`~("er unit points) i` ,Floor Area Not Solar Fraction (NSF), Z per un�c, ft2. 0.9 ic-i9 2c'-29 30-39 40-49 50-59 60-69 70-79 , 600-799 0 +3 +7 +1 IT E3"T +17 +21 +24 800-999 0 +3 +S +11 +14 +16 +19 1,000-1,499 0 +2 +6 +8 +10 +12 +14 1,500-1,999 0 + +3 +4 +6 +7 +8 +10 2 (00 and u 0 +1 +2 +4 +5 F +5 1 +7 1 +q All others (pe building paints) euo-899 0 +5 +10 +14 +19 +24 +29 +34 900-999 0 +4 +9 +13 +17 +it +26 +30 1,000-1,199 0 +4. -4-7 +11 +15 1-19 +2 2 +26 1,20fr1,499 0 +3 +6 +9 +12 +15 +18 +21 1,500-1.999 0 +2 +5 +1 +9 +12 +14 +le 2.000 -?,999 0 +2 +3 +5 +7 +8 +10 +11 3,0(0 ar.d uo 0 +1 +3 +s +5 4j +9 +I0 Table 3-21. Other Water I!eatlnq Pts. I System Type I Points I i I I Cas 0 i I I I I Heat F.mp 1 0 I I I I 1 Solar with Eleetrte ( I 1 Re+lstaace Backup 1 I 1 Meeting the Require- I I 1 cents 1u Part•2 I 0 I I I 1 I Electric Resistants I I 1 Daly -40 RESIDENTIAL ENERGY PLAN CHECK/INSPECTION SUMMARY FORM..J.- owner -Owner ��iC�1% Qzic,lc� Climate Zone f Permit No.... l6`J�3 Floor Area 1 Compliance path: Package ❑ A ❑ B ❑ C &Point System ❑ Budget 10 Other'. MIN R -VALUE DESCRIPTION REQ'D INSTALLED ITEMS (1) INSULATION Roof/Ceiling Wall ❑' Slab Floor Perimeter ❑ Raised Floor (2). INFILTRATION: ❑ (A) A vapor.barrier is required in climate zones,.1, 14 & 16. (B).All manufactured windows and sliding. glass doors shall meet the 1972 ANSI Air Infiltration Standards and shall be certified and labeled. (C) All swinging doors and windows leading to unconditioned areas . shall be fully weatherstripped. Tight - the above standard features plus:: [] -(D) Continuous infiltration.barrier Q (E) Electrical outlet plate gasket ❑ (F) Air-to-air heat exchanger (3) GLAZING: (A) Location Area Glazing %Floor Area' Single Double .Triple Total Bldg 377.34 1q. / 7 X North East South 0.O /.,f' X Rpr West .0 i x ❑ Skylights�— (B) Shading Shading Coefficient Description ' East South West Cl Skylights ® (C) South Overhang Length of projection __A� ft., Description z ❑ (D) Moveable insulation: Area ft Description (E) Thermal mass ❑ Type - Area Ft.2 HC= . R=. MC= Location ❑ Type - Area.. Ft.Z HC= R= MC= Location ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft. HC= R= MC=. Location ❑ Type - Area Ft. HC= R=. MC= Location ❑ Type - Area Ft.Z HC= R= MC= Location 7/83, r ❑ (4) MASONRY AND FACTORY-BUIIN-FIREPLACES shall be,equipped with .tight" fitting closeable metal or glass doors covering the entire opening of the firebox; a combusion air intake -equipped with a readily accessible, openable, and tight fitting damper to draw air from the outside of the building; and .a tight fitting flue damper with a readily accessible control. *1(5) HEATING, VENTIIATING, AIR CONDITIONING SYSTEM (A) Heating. Central Gas Furnace (brand and model number) SE Btu/hr = (heating capacity) [] Heat Pump (brand and model number) ACOP *1 Btu/hr (heating capacity at 47°F) Artiva Qnlar _ model number, type (liquid or air) solar fraction Collector brand and ft2 collector area collector orientation collector tilt 1;ated y -intercept rated slope Other U)ObO SM d (describe) (B) Cooling D Electric Air Conditioner (brand and model number) (seasonal EER) Btu hr (cooling capacity at 95°F) Electric Heat Pump EER Btu/hr (cooling capacity at 95°F) Other I (describe) (C) A TWO-STAGE THERMOSTAT, which controls the supplementary heat on its second stage, shall be required for heat pumps. (D)AN AUTOMATIC SETBACK shall be provided.for;all..thermostats, except those controlling heat pumps. ® (E) AN INTERMITTENT IGNITION DEVICE shall-be.provided for all gas=fired fan type central furnaces, gas-fired fan type wall furnaces and gas cooking appliances. (F) BACKDRAFT DAMPERS shall be provided for all fan systems exhausting air to the outside. ® (G) DUCT CONSTRUCTION & INSULATION. All transverse duct, plenum, and fitting.joints shall be sealed with pressure sensitive tape or mastic to prevent air loss and shall be insulated to conform to the provisions of Section 1005 of the UMC, 1976 Edition. 7/83 2 (6) DOMESTIC WATER SYSTEM , (B) Gas Only Gallons (brand and model number)(tank size) ❑ Heat Pump w/Electric Backup (brand, and model number) Gallons (tank size) _. 2- b* Active Solar (collector brand and. model number) (rated y -intercept) (rated slope) (solar fraction) ft2 ' (backup heater type, brand and. model-number)(collector area) (collector' orientation) (collector tilt) ❑ Location f Solar Panels. ❑ Other. ;(Describe) (B) TANK -INSULATION. Storage type water heaters and storage and backup tanks for solar systems shall be externally wrapped with R-12 insulation or greater. (C) PIPE INSULATION. The five feet of pipe closest to the .water heater and outside conditioned space shall be insulated with.a. minimum of R-3. Steam and steam conditioned space shall be insulated with a minimum of R-3. Steam and steam condensation return piping and recirculating hot water.piping outside the building envelope shall be insulated in accordance with T20 -1408(d). ® (D) FLOW RESTRICTORS shall be provided for showerheads and faucets as outlined in the new appliance efficiency standards and shall be certified to the Energy Commission. (7) LIGHTING (A) Lamps' used in.luminaries for general lighting in kitchens and . bathrooms shall have an efficacy of not less than•25 lumens per. Watt (usually florescent). *1 Submit.documentation of sizing heating and cooling equipment by.Minual J, sizing charts.(form #4) or other approved methods, section 2-5352(8), and fill out the following: Heating:. Winter design,temperature o27 °, elevation X00 ', heating load V " -BTU, elev t, .factor-�--•-= x heating load = maximum outlet capacity gas furnace Q'TD BTU Cooling: Summer design temperature, cooling load y BTU (USE ONLY AS A SIZING GUIDE, COOLING MAY BE INADEQUATE) 2 * Submit T.I.P.-S.E. chart or other approved system (form -#5) to document sizing of solar panels. ® DESIGN. COMPLIANCE STATEMENT: The above building design meets the requirements of . Title 24,.Part 2, Chapter.2-53 of the California Administration Code. 7/83 -1-="-= =-- - SIGNATURE BUILDING DESIGNER OR APPLICANT 3 'i RECORDED IN OFFICIAL RECORDS V O' BUTTE COUNTY,CALIr:ORNIA AT 1 iiF S T O MID VALLEY TITLE CO. 1986 JUL 29 Pik 12: 03 ELEQNIOR MI. BECKER / CLERK -RECORDER FEE 24293 Return'to DP'vl . AGRICULTURAL STATEMENT OF ACIa:OWLEDGEMENT J(�L� A.. C : FOR RESIDENTIAL DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be rkcar_de� prior to issuance of a building permit. NG';-C^r^PAAr- The property described herein is adjacent to land or included CRIG�NAC1)0C1JA,ENT within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort arising from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, I pruning, and harvesting which occa sionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural.zones which have as'a priority use for productive agricultural purposes,.and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary'farm"operations. All that real property situate in the Gounty of Butte, State of California, described as follows: Lots 140, 153, 154 and 163, as shown on.that certain Map entitled,`"Big Chico Creek -Estates Unit 4", which Map was filed in the Office of the Recorder of the County of Butte, State of California, on May 13,.1983, in Book 91 of Maps, at Pages 28.thru 33. a :Date•' 4 PROPERTY OWNERS Melvin W. Hegemie State of On 28 this the Cali€.. ) `- _—, day of July � 19 86 Butte ) SS.. before me, the undersigned Notary Public, personally County of ) appeared ®e®®e®®m®mae��c�e�mo®�aomo� ® - MARY R. CAS€BEER n NOTARY PU6LrGCALIFORNIA 60o Count ® MY C=w4*1M E)Pr8S Nov.30,1988 ®ma®a®a®m®am®a®®®®®®®m® Melvin W: Heaertier 9 known to me to be the person(s) whose name(s) .is subscribed to the within instrument and acknowledged that. he executed the same for the purposes therein contained. IN 14ITNESS WHEREOF, I hereunto set my hand and official seal. 042-48-0-01370,,014, 02.4 Present A.P. NO. 042747-0-023-0. A. otary:Public, Mary R. Casebeer k COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS } 196 Memorial Way, Chico.— Phone: 891-2751 7` County Center Drive, Oroville.— Phone: 538-7541 X747 Elliott Road, Paradise —'*Phone: 872-6307 i C RRECTION NOTICE r Ill 1n OWNER PERMIT NO. .•A routine inspection Indicates that the following violations of County Ordinance existai-the above address and should be corrected. Please notify this office when correction of work _-is-completed. If you have anyquestion ertaining-to this inaJter. or need addition I explanatio please contact this o Ice Immediately. inspector Date =OK 0 = Not OK Applicable MOBILE HOMES MISCELLANEOUS - =Not Date" i" MOBILE HOME" UTIL'ITIES"(Plans) OK. except #'s .: ` ' Date . + DECKS,COVERS,CARPORTS,GARAGES, (Plans)OK except#'s' 1. Zoning Requirements-Setbacks=Ea"seinents 1. Zoning Requirements -Setbacks -Easements: 4.".Soils;Special.MH Support -Sketch 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. -Sewer; Location-Test-Fall-C/OConcrete, ' = 3. Decks;:. Girders and/or:Joists-Decking-Bracing:Stairs=Rails i4:, -Water; Location -Test -Easement Needed -(Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.- Shthg.-Rfg.-Bracing Electricity; Location-Clearanc_ es=Grnd.-/ _,: / Amp -Concrete ' 6.'Gas; Location=Test-Wrap: / , / L" ft: , /-- /."Nat: or/ ; /"L"ft./r /"LPG - S. Alum. Awn-.; Col umns-Connections-Splice- Decal=Enclosures'. 6. Carports; Windows -Doors 7. -Utility Clearance 7.. Elec., 8. Frmg; Sills-Anchors-Studs-Rftrs-Trusses 9: Siding; Nailing -Veneer -Stucco -Mesh Card -B1 Date Card=1 ,' ",-'Date f 10. -Roof; Shthg-_Roofing Date Card -B1:= Date 1.1. Ext.; Steps -Doors -Landings Date'.' MOBILEHOME INSTALLATION. -(Plans) OK except #'s' l t. 1. Zoning Requirements -Setbacks -Easements { Card -B1 . -'Date Card -B1 ., Date 2. Footings;.Size-Spacing-Marriage_Line J Card -B1 Date Card -81 Date, -.'3.- Gas; MH Test -Demand -Valve -Connector. " l 4: Electricity; MH Test-Crossovers-Breakers=Clearances { Date PO Plans OK except #'s 5. Drain; MH Test -Fall -Flex Connector. acks-Easements 6. Water; MH Test -Regulator -Connector .. )....... S ; Compaction -Structure Stability 7 -Water.and Sewer Connected-C/O.to Grade -HD Approval ool Structure; Steel-Connections=Thickness= Dead Men -Lining 8. Gas and Electricity Tagged' : 9' Exits; Insp.-Sketch . { Elec.; Receptacles and Lighting, Distances-GFI • of Occupancy - .. • .: ... . �. _ { Elec.; Pool Li htin 15 volts-GFI ; g 9;'. . y f Elec.;.Enclosures; Conduit Entries -Terminals -Listed• ' j Elec.; Bonding; Metal w/5'-Circulating.!Equip.-Heater ' Ground ing, •Equip. W/5' -circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit' Card -B1:': Date Card=B1 ', DateElec.; Card -B1 Date Card -B1 Date j . , - , 9. alth. Department Approval J. f I j. . Plumb:; Cir. Test -Water Supply Test Card -B1 f Card -B1 Date rd -B1 L, .. Date '- -Date -B1. Date " or v6 v' = OK o = Not, J) RESIDENTIAL- (Single and Duplex) '-.Not Applicable _�:. • *-'Not Ready Date_;.'rUNDERFLOOR `(Plans),.OKexcept.#'s Date FRAMING(Continued)` 1. Zoning requirements, -;Setbacks, -Easements i 44. Hangers- Post'Caps-Anchors-Co nnectors 2. Ftg:,,Main; Soils='Steel-Elec:1-Grrid:-/ /" Ftg. Depth 45. Cing. Joist-Rftr.:Ties-Purlin-Roof Brac.-Truss=Shthng..-Rfng. 3. Ffg:,'Garage; Soils -Steel=/ /" Ftg. Depths 46. Fireplace Ties or Type A Flue -Fireplace. Throat.. _ 4. Ftg.; Porches & Deck's; Soil§ -Steel-/ /"Ftg. Depth 47. Attic Access; Size & Romex Protection -Draft Stop=Ins. Baffles 5. Stemwalls,-Main; Steel-Blockouts,-Wrapped 48. Bdrm. Windows or Exiting Doors -Sill Hgt. &Dimensions 6.54emwalis, Garage; Steel-Blockouts-Wrapped 49. Garage Fire" Protection Framing r - 7: Slab; Steel -Wrapped i 50. Property Line Firewall & Openings 8. Piers -Fireplace Ftg.-Steel 51. Ext. Doors -One T -Check Garage -3rd story; 2 -exits 9. DMM. Fall-Fittings-Test-2"way'C/O-Sewer, Test 52:`Stairs; Width- Head room=Rise-Run-Landing=Fire Protection 10 Gas Pipe-, Siie-Anchors 53. Plywood on Roof Overhang -Attic Vents-Rafter,.Outriggers . 1 -1< -Water Pipe; Test -Anchors -Regulator -Service Test 54. Siding -Nailing Veneer 12.:Electric; Underground '. 55. Stucco Mesh -Drip Screed -Fd. Vents-Underflr."Access 13: Plenurns'&•Ducts; Clearance-Material-Supprt-Ins. 56..Glazin6`Area-Gl6ss'Protection=Skylights-Pl66ti6 14. Girders-Sills-Anchor.Bolts-Joists-Vents-Cripples.: 57. Shear WaI16"Nailing-13'olts 15. Insulation 58:. Insulation-.Walls=Clg. - 59. Infiltration-Walls-Wndws ' Card -B1.. Date Card -B1 Date i'✓' Card -5f Date Card -131, Date. 1 Card -131 Date Card -B1 ' Date ' Card -131 Date Card -61 Date 'PLUMBING (Permit) OK exce tWs. 1 -Dat". 16.' Water Ht. Vent -Access -Combustion Air; :.' Date FINAL (Plans) OK except #'s" 77 7777. 17;;Water Pipe;"Test&Anchors-Nail Protection . 60.:Ext. Steps -Door & Sidelight,P[otection-Landings 18. D.W.V.; Test-Fttngs.& Anchors-Nail',Protection 61. Smoke Detector 19.,Shower Pan; Test; First Floor-Tub,Access 62. Furnace; Vents-Clearance-Comb.Air-Connector- In Garage; Above Floor -Ducts -Mach. Protection 20.'Test Tuba& Shower, :2nd Floor -Tub Access, 21: "Gas. Pipe> Size & Anchors 63. Bedroom Exiting a . 64. G.F.I. & Bath Fixtures"&.Tub Access -Spa 65. Elec.• Trim. & Subpanel; Breaker.;Sizes-Labels .••:..,. Card -131 Date Card -B1 Date l 66: Stairs &Rails Card -131 Date Card -B1 Date 67..Fireplace or Stove; Clearances -Hearth 68.,Elec. Outlets at Wood Panel; Int:,& Ext. Date ELECTRICAL (Permit) OK. except #'s' 22- Fixture -&'Transformer Clearance -Ins. Protection 69. Kit. Fixf. & Appliance; Grnd. -Air Gap -Cooking Clearance 23.'Elec. Receptacles Spacing -Lights ii Switchies at Doors 70. Elec. ,Outlets & Receptacles at Kit. "Counter 24. Size Boxes & No. -of Conductors -Stapled 71. Garage Fire Door; Swing -Landing -Closer 25. Romex Installed.Close to Edge of Studs &!C.J. 72• A.C. Duct in Garage -Damper 26. Equip. Ground made up w/Mach. Fasteners -,Bond Gas &Water 73. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor -Mach. Protection 27. 2 Appliance Circuits in.Kifchen & Conductor Size 74. Plb., Elec. & Mech. Equip. Listed for Location 28. Subfeed,.Wire Size / / ga. Cu or AI-A.C. Wire Size / /ga. 'Cu or Al ( 75. Elec. Receptacles in Garage; (G.F.I.)-Romex Protect 29. Range Circ. / / ga. Cu or Al -Oven. Circ. ,/ / ga. Cu or Al. Insulated Neutral Yes No 76. Insulation -Foam -Looked in Attic ❑ Yes 77. Guard:'Rails & Deck Construction -Post Caps 30. Service -Riser Conductors & Ground -Mai n, Disconnect 78. Fdn. Vents & Crawl Hole Door-Drainagge & Wood -Earth Clearance Looked under Floor ❑Yes 31. Equip. Clearances Panels -Motors -Mach. Equip. 32. Clothes Closet Light -Shower Light -Spa Light 79. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes O No; Planters ❑ Yes ❑ No 80. Stucco; Brown -Finish j Card -B1 Date Card -B1 Date 81. A.C. Unit; Disconnect, Electrical, Plumbing Card -B1 Date Card -B1 Date 82. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Openings. i Date MECHANICAL''(Permit) OK,except,#'s 83. Water Well; Disconnect, Electrical, Plumbing 33. A.C. Ducts'Insulation & Support 84. Exterior Elec. Trim; G.F.I. Receptacle -Underground 34. Vent Fan; Exhaust above insulation 85. Ventilation throughout House 35. Condensate Drain. & Overflow; Size & Grade 86. Glass Protection 36. Furnace -Vent; Access -Comb. Air -Return Air Vent -115 outlet 87. Corrections from Previous Inpections 37. Attic Access & Platform if Furnace in Attic . 88. Gas Test -Meters Tagged; Gas -Electric h 89..Water & Sewer Connected -C/O to Grade -HD Approval 90. Energy Compliance. Certificate -Other Certificates Card -B1 Date Card -131 Date � _ Card -B1 Date Card -B1 Date Card -B1 Date Card -B1 Date Date FRAMING (Plans) OK except #'s Card -B1 Date Card -81 Date. 38. Sills, Proper Material & Anchors , Card -B1 Date Card -B1 Date 39. Walls Studs -Nailing,; Spacing & Bracing-Plates-Sound Comments at Final: 40. Bearing Walls over Girders & Floor Nailing 41. Draft Stop in Walls (rat proof) 42. Fire Stops; Furred. Gel lings-Stairs-Chases-Tub 43. Header & Beam=Size & Bearin (NOTE: An entry must be made each time you visit job site) .J .. - COUNTY.OF BUT'T_E. DEPARTMENT OF PUBLIC WORKS ERMIT N 7 County Cente'r,Dnve.-'Oroville, California,95965'-- Telephone: 916/538-7541 APPLICATION PERMIT '. ASSESS R PARCEL NUM8L9R ZONI G - BUILDING PE - MIT OWNER, - TELEPHONE SQ..FT. OCC. BUILDING• VALUATION - ' OWNER'S MAILING'ADDRPSS •/- _ - ONTRACTOR'S"NAM a•' _,e' - EEPHONE "• - .CONTRACTOR'S MAILINGADDRESS .. "r -� /l�� Fireplace: "CONSTRUCTION L"E ER - .. UNKNOWN Total Valuation 'Filing Fee $. 10.00 L••ENDER'S MAILING'ADDRESS - - - - l . Permit Fee $ -ARCHITECT OR ENGINEER ,' '=' .. LICENSE NO. - ' Pian'Checking Fee. $ Energy Plan Checking Fee •• $•;. ARCHITECT'OR ENGIN•EER'S MAILING ADDRESS, - f -Penalty $, •-.•BUILDING ,ADDRESS,-. • - i, ;.. - Permit fee $ PLUMBING PERMIT' Filing Fee 10.00 J/ Each Trap ' -Sol ar' or heat pump water heater .20 .00 LOT NO., .<:l S SU.B DI VI510N.N AME .PARCEL MAP -�2 Materplping - 5:00,+ Each qas water heater or vent . 5.00 USE OF STRUCTURE y� SF ❑ . ,Duplex❑.' Mobilehome❑ Other- SPECIFY Gas piping system 1,- 5 outlet's 5:00 Building sewer 5.00 Mobile Home- IS I G' W'J 10.00 ea TYPE OF, WORK News. Addition ❑ Remo�ddeel ❑- Uti Iities ❑ Installation ❑ ''Other.[] Describe work: X „ Permit fee $ ' Contractor ELECTRICAL PERMIT Filing Fee 10.00 - /- �. _.. (Q Main service 600V OR LESS' 100 AMP OR LESS 10,00 ' Main Service .EA, ADD -L. 100 AMP - 2:50 - CONTRACTORS LICENSE -LAW I declare.under penalty of perjury, (check one): dam licensed under provisions of Chapt. 9; Div. 3 of the Business - and Professions Code and my license is in full force and effect. License No. '3'5 7.19 �^ Classification ��� "- - - 1, 'as the owner,. or my employees with, wages as.their sole'compen- sation, will .do the work,and the structure is not.-, or offered for sale. (Sec. 7044): EJ I, as the, owner, am' -exclusively contracting with, licensed contract- ors. (Sec. 7044) ❑ t I am exempt ,under Sec. Business and Professions Code' for this reason NEW CONST._ ( DWELLING OCCUP.EI OR: AODNS.' 1 ACC. BLDGS. . . ) /4sq.ft NEW CONST ;'TI.OUTLET NON-RESID BRANCH IRC ITS 2.50ea " BOWER APPARATUS 61 . SINGLE OUTLET.CIR, I Ex. Occu (6 20050t PC UTLETS OR FIXTURES BAL930 "- FIXED APPLNS. OR Ex:•Occup. OUTLETS (RE SID ) EA-.) 2.00 Temporary service 10.00- Mobile Home Facilities, ` 15.00. Mi'sc tiyiring 15.00 Permit. -Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ; ❑ . The permit is'for $100.00 (valuation)' or less. I have placed on file'.with, the County of Butte Building Department a. Certificate of Workmen's Compensation"Insurance or 'a Certificate of.0 nt to Self -Insure. ; all not employ any person in any manner so as -to become subject -'to the W. -C. laws of California.. Notice oto Applicant. If after, making this statement, should you become subject. to the W. C. provisions, of the Labor. Code, you must forthwith comply with such provi:sions'or this-permiLshal l be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 :'Heating Cooling .Mood 3.00 !Ventilation " Permit Fee $ Contractor I'certify,that I have•read•this application and state that the above information is correct.' I_agree to comply,to all.County Ordinances and State Laws relating to`buildi.ng construction, and -hereby authorize representatives of the Countyot Butte`to enter upon the above-mentioned property for inspection purposes.. " .I`also'agree.to,save,'indemnify and keep.ha'rmless th'e.Couniy'of Butte against alI._Iiabili ' ,`-judgments,�costs,'and expenses which'may in any way accrue agai st I County ' con equence of the granting.of this permit. / _a c�� X Date to 7.Signatu�e'ofApplicant- Owner❑' 'Conrra-ior❑ Agent❑ :;Ari'0SHA.pe}mit is `.required for excavations over 5'0" -.deep and demolitlon'or construct -DIRECTOR ion of structuies'over. 3 storiesin height. Mobile Home Instal latlon'Fe.e �; $ Energy Inspection Fee.: $ TOTAL PERMIT FEE $ 3 OCCUP. J,.00N5T;TYgK1 I.FLOPO PARCEL 'PD MD ,ID9U This. permit is hereby issued under sions of.the •Butte County. Code and/or work "indicated above'for`which OF PUBLIC gy'.. T.1. PE 1 "EXPIRES' Date the applicable provi- . resolutions to do fees have been paid. WORKS " Date Receipt No.° WNITE D.P.W.; YELLOW-"8Z530R,. PINK -INSPECTOR _-GOLDENROD-APPLICAN'T, �f h _X 1. ! -t ifn w -e ...k rI 11 'tI "�, a '' f• Y ,� i'_ h,r .i d° k iJ '..�� �. t 'e1 f i - r r T:' .t ,-ti 'h•.5t ft a... y f -;'! j_ e , •, t •f �y i` �-' t. lY _ C �_ i:: 1 'j .y '' r v�,. < h i 1 a- ,r`' F 5 - i. - e, ai r 'C# ti, L k4 r i .- I' j '` ..!`rF, f, �� i. - �.. 1 •4 � -N �t ,,; 1. r Y g `� �r t , 1 .- _ { , .t r Z - - y - _ ' 7'. 1 _ _ii. _ A t.. t f 1: -,. _.7.. .o, „ _ ,✓l. _ -K _ S.. r<Y 'a.,, 4•r<s.- 'A r' L1'" :' { �. ��'.•.i �✓` i t"- ri J• - '{ Y', - ! ;q 'Y,t�:;c�S� 'k ,fv f r 'r. f r f i a,.,, 'i� r - 'Y S :l C', - +, T • Z ?'J� 1 a _ •fes 7 �.. t r L `5. - i _ : 4 t j i 1 '4 ^ a` �• , ;; I . , - .: �� t- �r i,, E• ):.• n �f t j' ;v _ . k re .. ri a it r' rr, •? ! , F. r r t , r - ; is _ l s ' 1 '+: ,, f ' {. h {1. 4�•', a. _. t 1 .� y'` ,j. y d f � lY Y MI ,,. 'i w /`r !+' `iX ~ r ' `, ... F y ,G 4 } -f , 3 x 1 r . - _ t 1 i 5,fit Y j r t ,- ,, l e"i wY,; !. 1 { .N ' -_i - _ f st i d ,,* i-Ct-.:'r f1 .-`: ,{ _.4, ISI =, y r. f� _t�_ :,,j.: b J^ i t. •fw �i rr 1 ?. xl - .,3 _ 1 ' .4 t �. G - r. t .:R, , "` {... ..i 1. Y M t ` a � ; '{. , f J t _.• -' '.:_ _ ` f 1 � � . is #' .2'rI. tH. . � - a I - _ {. Z:.� !kr,.. r 11 + '. r- rt. '� t - > Irt '. 1 Kir a- '.s t t .. w k 'P { �,. 1 {," ' l - .( T1 1. ai { �' *y,' } .r t - � .c TL• -,e ;\. �- `P v "k, % • G. 1 u �., 3 -� ' S�1 y. 7iCt S �' i� �';,t :} _ .t i ,1 J 3 s; 't..i _I. -.1 ti', - ti y°' �,. 1 �r i. l +,� t .� 3 {. 1. I � ': l C .t.. - a' �., f ; r,. 7 „ _ - z G - c t '� J .Y 4. _ !- L '\ ! !. f Ya:, l -.i�t ' _ ` fit.}1. bs {1 t. f '� L7 5 1' . � .n Q } � e _a - ;f `. a ,.. r! ti - ..t'e t 7. {. J _ is - y } �. - 1. Y? r ' r .. .r. i�- ., , •,p,' '1i+ �", +�F Y. r,- ,".• . .,T F 4i`.L" S -iI.i%7 ). ` �'� G. �'' .''' 'f. �l �i _ + ':. �_!--.'+�=•'S.�'_; 1 - t _k•- 7 $.3.: �l r�i'. 0., '•�^ f M1� i Ls . 1 t '7 , � r. - •`t. t. , _ } .i �J; '` t- rt` _ - ( :tr,.,. i` c : ,y 'F x. ;f a -,y_{. t ° h ✓< Y 1 .eY .".��' i 5 _ �'.. .. i �.fi l ice. - S' , s_.a. ;;�. t .! t f J- a - Y t y, ,Y.. fY S , �. _ "tt Y h $ t ;Ir E:-., LM. k 1.- ',: �, 1 e i, t1. ;� , "( _ =fid ,u,C j _ Z < i t -t, , i - l 1 Y,. { y �. _ _ :t - _ r t ; - ,d a. _ �, 1 l r� , :��� R .t > - r y t' ! r ,m,-t,� i. t ! - a J rf l) 1 _ -.j,. r' 1 . _ s•- � , tb. .ice •t - a, ' r Y 1 'a i rt. t - i° -i . .- ! :i' J y' ?I >. •` 1 _` .! ! . I rr Y: i:yv,r,•:" ;17riCi. f '��,# 7:'$Si'( .76 -� : �. wQ:3C...T" L ori',' fi 'v'T "',•�`'.7r'` .".y;.,'r'. '" .M - COUNTYJOF BUTTE - DEPARTMENT OF1 PUBLIC WORKS - BUILDING DIVtISION 7 COUNTY CENTER DRIVE - OROVILLE CALIFC�RtJI`A{95965 - TELEPHONE: 916/534541 rrr�i1F PERMIT APPLICATION DATA SHEET Permit No. OWNER A. P..No. � r `. Proposed Building Use � Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and:/or, issuance: DATE RECEIVED APPROVED 1. All items have been submitted. . . . . . . . . 2. Plot plans in duplicate/triplicate, signed by preparer of plans. 3. Complete plans in duplicate:/triplicate, signed by preparer of plans, 4. Complete engineered plans and calcs, with wet signature on plans. 5. Plans with Energy Design Compliance Statement. . . . . . 6. CUSD "Fees Paid" Stamp on Floor Plan 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ , 9. Letter of signature authoriz . . . . . . . . Sanitation approval from 2�� Health Dept. G - a�f — fi 7 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. 13. Contractor's License Information (no., name style, classif.) ` 14, Owner -Builder Verification (Given to owner0, Mail to owner El _15. Improvements may be required. . • . . . . . . . . 16. Mobi lehome Installation Data. . . . . . . . Pre-Inspec.request to (Date) 17. Pre -Inspection for Required, Building Inspector 18. Recorded copy of Agricultural Acknowledgment Statement. 19. Driveway Permit. 20. Plot plan approval from city of 21. 22. \ When you issue the permit, process as follows: Mail to owner, !ail to contractor., Telephone and hold for pickup at—off ice, Deliver w/inspector,. Other Applicant 0X/ Copy,of plans sent Health Dept., Fire Dept,, Other Date The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. r 2,. Additional items required: x Contractor,` designer, owner, was advised of above required data by_phone---jnall—counter by date Contractor,. designer, o er, as advised of above required data by—phone—mall counter y date Plans checked by - Date Plans approved I Date _ Sets of plans on hold in File cabinet AP folder Copy—DPW — Flours: 10:00 a.m. - 3:00 p.m. �` � t , . 1. f` ` � T. TO: Building Department FROM: Environmental Health, Chico SUBJECT: Sanitation Clearance 1,6 Co /b Owner Locaticth AP Plan approved for: sewage disposal water supply Hold final for: water supply Final clearance O A . for: water supply Clearance for bedroom mobile home. Other ACW Note*** tarian Date IM July 30' 2002', Peter Lana 1620*'Lazy trail Drive Chico, CA 95926 Department of Development- Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX Assessor Parcel Number: 043-720,-010 Building Permit.Number: 02-1693 Thank you f6r submitting the plans for your building project. The plans have been reviewed, and the plan exam'iner's comments are listed below. Please respond in writing to each item by completing and returning the enclosed PLAN REVIEW RESPONSE FORM. Your complete and clear response will expedite the re -check and approval of this project. NON-STRUCTURAL COMMENTS: Provide location of heating and cooling equipment. The required fire separation assembly between the garage and the house must be installed to provide a complete separation. Assembly must be carried to the roof sheathing. Framing for the roof interferes with this requirement. All walls and ceiling will need to be covered with 5/8th's Type X sheetrock to meet the requirement for a complete separation. 2x8 ceiling 01st do not meet required span. Please resize joists for span with sheetrock ceiling. VA((.3 FAu/.Lt. ckk1q., JJ&4 *Q,-, Z. (fig-n�;t Gte U 6`f " 4 Foundation plan does not note which foundation detail will be used at the bearing wall between the garage and the recreation room. Please note foundation plan. The size of the roof truss is not noted on the plan so I'm assuming you will be using a 11 7/81h's member. Please confirm size you will be using. Please provide two sets of energy calculations. You signed our handout for energy requirements but your plan does not meet the requirements set out on the handout. If you were to use this handout you will need to change your plans to meet the following requirements: rovide a larger roof truss to meet requirement for R-38 insulation and one inch air gap for roof venting. R-38 insulation will not fit into a 117/8th's rafter without compressing the batt and then you have a reduced R -value of 37, without required venting. Provide an Energy Standards approved radiant barrier. q ie windows'must meet both the U - factor and the solar heat gain coefficient -therefore, you cannot re -use existing sliding glass door. You will need to provide anew sliding glass door. Your ductwork to the new room will be required to be sealed and tested for code ompliance for air leakage, you will need to provide a TXV valve on your air conditioner. ;K last two items will be required to have T special inspection, which you must hire, at your own expense. The last two items can be waived if your provide windows with a maximum 0.40 U -Factor and a maximum 0.35. -solar heat gain coefficient (all windows, including study windows) and you provide a high 1 of 2 PROJECT PROCESSING RECORD Applicant: Owner: A.P. #• 043 -7.00 0 l Permit #: d a '10` j Work Description: A—&,L, Date Description of Step or Status l -d UT{ S Y fir. i � i. Y. •: o o RESIDENTIAL PLAN REVIEW GUIDE o ___::- o t •t 0 o SINGLE FAX flLX, DUPLEXAND MISCELLANEOUS ONLY '2'a � 1 . Y : 4 'moi � � 1 ti _�•t. Owner:' Q/Y Building Permit Number:. Plans Examiner: Martha Christy, A. P. Number: ENERAL: T 1 Zoning requirements — (number of permitted living units). Plans signed by the designer. Proper description of work on the application: Existing violations on the property: Recorded notice of violation..' Building permit valuation. LOT PLAN: Complete parcel size and dimensions. Setbacks, side yard, easements, etc. Other buildings or structures. Grading; fills and/or drainage.' 'Flood hazard. Special conditions on Parcel Map: Noise ❑ SRA ❑ Fire Sprinklers ❑ Water Tender ❑ Traffic and Drainage fees ❑ Federal Aid Route and/or Federal Aid Secondary Route setback requirement Building or utilities across lot lines (Lot.merger approval by Butte County Land Development FLOOR PLAN: 'Plans and specifications drawn to scale with dimensions and of sufficient clarity (UBC section 106.3 3) /2'' ' 1.0% of natural light and 5% of ventilation (Uniform Building Code section, IMP)—, �! Escape or rescue windows shall have a minimum net clear openable area of 5 7 square feet: The minimum net clear openable height dimension shall be 24 The minimum net clear openable widthdunerision shall be;20" = , When windows am provided as a means of escape or rescue, they shall have.a friishedtsillheightsnot. more 'than 44" above the floor (Uniform Building Code section 310.4). 4. Skylights (Uniform Building Code section 2409 & 2603.7). f-5. Glazing.in Hazardous locations (Uniform Building Code,section 2406). , Habitableace shall have a ceiling height of not less than 7 feet 6 inchesx ece t as otherwise SP g. � P perinrtted iri•ttus `. "� section. Kitchens, halls, bathrooms and toilet compartments may have a ceiling height of not less than 7 feet measured to the lowest projection from the ceiling (Uniform Building Code section 310:6.1). All habitable rooms except kitchens shall have an area of not less than 70 square feet and not less than7feet in any dimension (Uniform Building Code section 310.6.2 &310.6.3). GFCI in baths, garage, kitchen, wet bar, and exterior receptacles (NEC 210). r,. Water heaters which depend on the_combustion of fuel shall not be installed in a room used or designed to be used for sleeping purposes, bathroom, clothes closets or in a closet or other confined space opening into' a bath f r' or bedroom (Uniform Plumbing* Code section 509.0). Fuel burning equipment shall not be installed in a closet, bathroom or a room readily usable as a bedroom,, or in 'a room, compartment or alcove opening directly into any of these (Uniform Mechanical Code section -304.5). 1 ' Garage firewall separation -required oD. garage side including supporting walls and posts (Uniform Building..'." Code section 302.4 exception #3).. O. r00� �'�.': j2C(,}'i h.Z7•Q�, Under no circumstances shall a private garage have any opening mt6 a'room used -for sleeping purposes ' -(Uniform Building Code section 312.4); 5 Wood stove location - Alcove — UMC section 205 confined space & 223 unconfinedspace & 304 2) Smokedetectors (Uniform' Building Code section 310.9:1). Page 1 of 2 y Water closet clearances (Uniform Plumbing Code 408.5). 1 Shower compartment minimum 1024 sq. in. & 30" circle (Uniform Plumbing Code 412.7). 17: earing walls shall be supported on masonry or concrete foundations that shall be of sufficient size to suppo�'�jj OVA I d / all loads (Uniform Building Code section 1806.3). Wm - NQ, -,D T/1'a roes -r) STRUCTURAL DETAILS:Oj ? Lj ') 1. Braced wall panels shall start at not inore than 8 feet from"each end of�a braced wall line. Braced wall panels t'�►� �l must be in line or offset from each other by not more than 4 feet (UBC section 2320.11.3). Spacing shall not �Qlyi exceed 34 feet on center in both the longitudinal and transverse directions (UBC section 2320.4.1.) Braced wall ((J,r0 Ywt lines must be continuous throughout the structure. i {c OV; -A 2. A California licensed architect or registered engineer must prepare a lateral analysis for the areas of the building $� that do not comply with the Uniform Building Code. This must include the designer's "wet" stamp, signature, registration number and expiration date on all sheets of plans depicting the designed elements and cover sheets of calculations. Clerestory requiring balloon framing and/or engineering. 4., Foundation plans complete enough to construct building (Uniform Building Code Table 18 -I -C); 5. Floor construction details complete enough to construct building. I 6 Elevations and wall construction details complete enough to construct (building. _ rO� C 7,Roof construction details complete enough to construct building. -ZA6 8. Fireplace construction details and calculations if necessary. J 38 9. Garage door header size(s). i 5 4�� j ` 4" 10. Porch header size(s). a i�Pit 11. Typical header size(s). 12. Stud heights. rylpde le_dl 12 'gh expansive soil - special foundation design required.A,YIj l- . ,14' etaimng walls requiring design. JJ �.Npsum wallboard nailing inspection required. If the area below the lowest floor is fully enclosed, than a minimum of two openings are required with a total net area of at least one square inch for every square foot of area enclosed with the bottom of the openings no more than one foot above grade. Alternatively, certification may be provided by a registered professional engineer or architect that the design will allow equalization of hydrostatic flood forces on exterior walls. Building must be designed and anchored to prevent floatation, collapse or lateral movement. Construction design requirements must be shown on the building plans. Electric, heating, ventilation, plumbing and air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accuml lating with the compogents during conditions of flooding. .NIJSCELLANEOUS ITEMS: ,Y Stairway details - landings, rise and run, head clearance, handrails (Uniform Building Code section 1003). ii Guardrails (Uniform Building Code section 509). Brick or stone veneer (Uniform Building Code section 1403). �*✓ Exterior plaster - weep screeds (Uniform Building Code section 2506.'5). Roof pitch for roof covering (Uniform Building Code Table 15-B-1& 2, 15-D-1 & 2). Foam insulation - protection. 36" halls and stairways (Uniform Building Code section 1004.3.3.2). wo exits on three - story dwellings (Uniform Building Code section 1004.2.3.2). �.,Underfloor access and ventilation (Uniform Building Code section 2306.3 & 2306.7). ttic access and ventilation (Uniform Building Code section 1505). f _-&*it haWG �2- 3Qj Vunnergy od requirements. desigmcompliance and supporting documentation. DF responsible area requirements. BUILDING PERMIT REQUIREMENTS:pQ,u 1. ❑ SRA. 2. ❑ Flood elevation certificate. ,Q„ ,(��„ L f2..._r/ er--c6zk— 3. ❑ Fire Sprinklers required. 4. ❑ Special Inspection requirements. 5. ❑ Use Permit conditions. 6. ❑ Sub -Standard Housing letter. �(9(Q Whem i n 5+V-11 e CO Page 2 of 2 1rOOm lis �W . a '`i . _._ ' I rWIWWWI sR..^`, �_ '_ iRWIW'WY1911Wr•i 1 AAJ APPROVW Duft County D n" 1.4 Y% L -C) Environmental Health Chico, Califomla