Loading...
HomeMy WebLinkAbout047-320-061047-320-061 PERMITH95-0471 CRESPO, Raffael 14031 Heidirose Ln., Chico Cont; Frank Koulczyk New Single Family 047-320-061 PERMITN95-2436 CRESPO, Raffael 14031 Heidirose Ln., Chico Cont: Frank Koulczyk New Pri Det Garage 047-320-OGI 00-3063 RECK, RAE JEAN /. 14031 HEIDI ROSE LN, ICO a� CONTR: ARTIC AIR CHANGE OUT HVAC B07-2404 047-320-061 MISCELLANEOUS Phtovtaic Sys Roof ROOF MOUNT SOLAR SYSTEM 14031 HEIDEROSE LN RUMIANO, MARY C TRUST 11 J BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #:(530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #:(530) 538-7541 FAX#: (530) 538-2140 WEBSITE: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 14031 HEIDEROSE LN Owner: Permit N0: B07-2404 APN: 047-320-061 RUMIANO, MARY C TRUST Issued Date: 11/27/2007 By TMP Permit type: MISCELLANEOUS 14031 HEIDEROSE LN Subtype: Phtovtaic Sys Roof CHICO, CA 95973 Expiration Date: 11/26/2008 Description: ROOF MOUNT SOLAR SYSTEM (530) 893-8007 Occupancy: Zoning: Contractor Applicant: Square Footage: S P G SOLAR INC S P G SOLAR INC Building Garage Remdl/Addn 521 CAL OAK ROAD 521 CAL OAK ROAD OROVILLE, CA 95965 OROVILLE, CA 95965 Other Porch/Patio Total (530)533-5988 (530)533-5988 '.' FEE INFORMATION DBMSC Photovoltaic System $408.93 Total Charged: $408.93 Fees Paid: $408.93 Balance Due: $0.00 Receipt No: B5421 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License S P G SOLAR INC 759086 / B C46 C10 / 01/31/2008 Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) is in full force and effect. of Division 3 of the Business and Professions Code] or that he or she is exempt therefrom and the X basis for the alleged exemption: Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500); �_ 11/27/2007 Please check one of the following: ontractof S Signature Date ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK, �" ` WORKERS COMPENSATION �s.. 4 DECLARATION AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of the property, who builds or improves thereon, and who does I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: HAVE AND the work himself or herself or through his or her own employees, provided that such improvements ❑I WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are notintended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or performance of the work for which this permit is issued. improve for the purpose of sale.). IJ41AGE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by [ '1 ❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Provessions Code: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. The Contractors License Law dows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Carrier: STATE FUND Policy Number: 046-0016178-2006E,p Date:04/01/2008 Contractors License Law.). (This section need not a completed if the permit is or ons und>F red dollars ($100) or less.) ❑ I AM EXEMPT under Section B. & P.C. for this reason: ❑I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation laws of California, and agree that if I should become subject to the workers'X 11/27/2007 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those Owner's Signature Date provisions. X 11/27/2007 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building Z�J "nature Date ARNING: FAILURE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal D HALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, with injury, including death, and property damage caused t is arising out of, a in any way t authorize the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND ATTORNEY'S FEES. use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte County to enter the above mentioned property for inspection purposes. I hereby certify that I am the property owner or am authorized to act on the property owners behalf. PUeN9/►J6L11/27/2007 CONSTRUCTION LENDING AGENCY I HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name of Permittee [SIG Print Date the performance of the work for which this permit is issued. (3097 civ. code) Owner 1:1 Contractor OR DAgent for Owner for Contractor FILE COPY Lenders Address City State zip Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds NOTICE TO BUILDERS Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things you can do to expedite your permit: 0 Make sure your application is complete. 0 Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit. A permit may be renewed (for a fee) prior to expiration an indefinite number of times, provided construction progress has been documented by the Building Division during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications (not yet issued) must be requested within two years from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge of $54.99 to process the refund application will be assessed. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at hitp:Hmunicipalcodes.lexisnexis.com/codes/butteco/ Reference Number: B07-2404 Location: 14031 HEIDEROSE LN Parcel Number: 047-320-061 Owner Name: RUMIANO, MARY C TRUST Description: ROOF MOUNT SOLAR SYSTEM Date: 11/27/2007 Phone: (530) 893-8007 Signature of Applicant: �_ Date: 11/27/2007 FILE BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" OWNER INFORMATION Last Name p JM /4-Q First Name,J l Mailing Address 1020 l H,0a6 464— t A-,A)E City eAl[o Stateef} Zip ?fq 73 Phone%3v� X13—gaj-7 Fax E-mails CONTRACTOR Name SPG 5014-R" Address 5-Z1 ejtt 0Ag gB City 6,el) [JI LL.E State,, Zipjp$+,dS Phone53 3_ 59 g$ Fax E-mail Lis. # 7S9 d 6 Class a jol - —40' APPLICANT INFORMATION ARCHITECT/ENGINEER Name City 41?Z)01 t14� Address zip,'59,6-5- 59,6S City Fax State Zip Phone Fax E-mail State License Number APPLICANT INFORMATION Name,5P4 SO 1-141?- 14-2Address Address SZ/ 1064lG /L%% City 41?Z)01 t14� State C� zip,'59,6-5- 59,6S Phone Phone x-33 _ �$ Fax E-mail APPLICANT SIGNATURE X PERMIT NO. BIN # PROJECTLOCATION AP# Property Address lggl10� City eglLo e,4 `y'9 73 WORKER'S COMPENSATION Policy Number 0,0 �6 7 _ 2D0 7 Carrier STA�q If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: S.D2 eu) QWn)var*G poeig ,440V,077 -Eo syr 2-61 165 Z S 2 te"'.fi Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): For office use only: Zoning Flood Zone SRA I Yes I No Occ. Type Const. a 0 D �w profile, roof= " , ice• t � i : r" �gratedaookrfor iVp s and other Q�1 •- \ - ' ices! ac .mount ales ose�rvater= `•/+•� _�.�,■ �j K `t iY l tC - �` '•• S j!>r�. I is Hiqh Performance Products o Designed for pitched composite shingle roofs © Minimal or no shingle cutting required MAL,c� 25% faster installation than standard mounts Lower installation cost c Low -profile design enhances aesthetics while allowing ventilation and drainage e Extremely durable & corrosion -resistant c Provides positive waterproofing e Wind resistant to Category 3 130 mph) 2. c Can also be used to mount antennas, Y-a" -� -'w �%^. �• f'' _0 solar thermal, flagpoles, air conditioners, etc. o Available in clew„ r galvanizzeeeddor,��J'ry black4finishes GDEPMTmer EM ask /1 r1 r o Designed for pitched composite shingle roofs © Minimal or no shingle cutting required MAL,c� 25% faster installation than standard mounts Lower installation cost c Low -profile design enhances aesthetics while allowing ventilation and drainage e Extremely durable & corrosion -resistant c Provides positive waterproofing e Wind resistant to Category 3 130 mph) 2. c Can also be used to mount antennas, Y-a" -� -'w �%^. �• f'' _0 solar thermal, flagpoles, air conditioners, etc. o Available in clew„ r galvanizzeeeddor,��J'ry black4finishes GDEPMTmer EM ask � 1.60 �L� Solid Aluminum Block LO N 1.63 V C? Galvanized (Clear or Black) �b Off/ Gj• X3/8" threads Stainless Steel #304 "At Marin Solar we pride ourselves on qual- ity, aesthetics and performance. Using TTI Flat Jacks and Flush Mount products gives us that edge. The biggest advantage is peace of mind from roof leaks with the TTI Flat Jack flashing system." For more information on this product and other available products, ,Lplease contact us at: Roy Phillips President Marin Solar, Inc. ITT Thompson Technology Industries, Inc. 61 Paul Drive San Rafael, CA 94903 SPECIFICATIONS KC20OGT ■ Physical Specifications Unit: mm(in.) 990 (39.Oin.) 36 (1.4in.) 946 (37.2in.) 22 (0.9in.) 22 (0.9in. c v in N on to C N n!�O oo v (V v op o (O 04 36 (1.4in.) ■ Specifications 1 Electrical Performance under Standard Test Conditions (*STC) Maximum Power(Pmax) 20OW (+10//-5i) Maximum Power Voltage (vmpp) 26.3V Maximum Power Current (Impp) 7.61A Open Circuit Voltage (Voc) 32.9V Short Circuit Current (Isc) 8.21A Max System Voltage 600V Temperature Coefficient of Voc —1.23x10-1 VIC •STC :1Mdia— 1000W/ma, AM1.5 spectrum, modul9 temperture 25t 1 Electrical Performance at 800W/m2, NOCT, AM7.5 1 Maximum Power (Pmax) 142W Maximum Power Voltage (Vmpp) 23.2V Maximum Power Current (Impp) 6.13A Open Circuit Voltage (voc) 29.9V Short Circuit Current (Isc) 6.62A NOCT (Nominal Opemung Cel Tempemtum) :47t 19KHOCERa KYOCERA Corporation ■ KYOCERA Corporation Headquarters CORPORATE SOLAR ENERGY DIVISION 6 Takeda Tobadoho-cho Fushimi-ku, Kyoto 612-8501, Japan TEL:(81)75-604-3476 FAX:(81)75-604-3475 http://www.kyocera.com • KYOCERA Solar, Inc. 7812 East Acoma Drive Scottsdale, AZ 85260, USA TEL:(1)480-948-8003 or(800)223-9580 FAX:(1)480-483-6431 http://www.kyocerasolar.com • KYOCERA Solar do Brasil Ltda. Av. Guignard 661, Lois,A 22790-200, Recreio dos Bandeirantes, Rio de Janeiro, Brazil TEL:(55)21-2437-8525 FAX:(55)21-2437-2338 http://www.kyocerasolar.com.br • KYOCERA Solar Pty Ltd. Level 3, 6-10 Talavera Road, North Ryde N.S.W. 2113, Australia TEL:(61)2-9870-3948 FAX:(61)2-9888-9588 http:/Avw .kyocemsolar.com.au/ • KYOCERA Fineceramics GmbH Fritz Muller strasse 107, D-73730 Esslingen, Germany TEL:(49)711-93934-917 FAX: (49)711-93934-950 hftp://www.kyocerasolar.de/ ■ Cells } Number per Module 154 ■ Module Characteristics { Length x Width x Depth 1425mn(S62n)x99Drtm(39.Oe1)x36nrtI1AW Weight 18.5kg(40.7lbs.) Cable(+)720mm(28.3in),(•)1800mm(70.9in) ■ Junction Box Characteristics I Length x Width x Depth 113.6mm(4.5i )x76mm(8.On)x9mm(0.4in) IP Code IP65 ■ Reduction of Efficiency under Low Irradiance ) Reduction 7.8% Reduction of efficiency from an Irrandiance of 1000W/m2 to 20OW/m2 (module temperature 251C) Please contact our office for further information • KYOCERA Asia Pacific Pte. Ltd. 298 Tiong Bahru Road, #13-03105 Central Plaza, Singapore 168730 TEL:(65)6271-0500 FAX:(65)6271-0600 • KYOCERA Asia Pacific Ltd. Room 801-802, Tower 1 South Seas Centre, 75 Mody Road, Tsimshatsui East, Kowloon, Hong Kong TEL:(852)2-7237183 FAX:(852)2-7244501 • KYOCERA Asia Pacific Ltd. Taipei Office 10 R., No.66, Nanking West Road, Taipei, Taiwan TEL:(886)2-2555-3609 FAX:(886)2-2559-4131 • KYOCERA(Tianjin) Sales & Trading Corporation 19F, Tower C HeOiao Building 8A GuangHua Rd., Chao Yang District, Beijing 100026, China TEL:(86)10-6583-2270 FAX:(86)10-6583-2250 BUTTE COUNTY BUILDING DEPARTMENT AP+PROVED Kyocera reserves the right to modify these specifications without notice LIE/109M0703-SAGKM KC20OGT HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC MODULE THE NEW VALUE FRONTIER 1121104[r.1 LISTED HIGHLIGHTS OF KYOCERA PHOTOVOLTAIC MODULES Kyocera's advanced cell processing technology and automated production facilities produce a highly efficient multicrystal photovoltaic module. The conversion efficiency of the Kyocera solar cell is over 16%. These cells are encapsulated between a tempered glass cover and a pottant with back sheet to provide efficient protection from the severest environmental conditions. The entire laminate is installed in an anodized aluminum frame to provide structural strength and ease of installation. Equipped with plug-in connectors. APPLICATIONS KC200GT is ideal for grid tie system applications. • Residential roof top systems • Water Pumping systems • Large commercial grid tie systems • High Voltage stand alone systems • etc. QUALIFICATIONS • MODULE: UL1703 certified • FACTORY : IS09001 and ISO 14001 QUALITY ASSURANCE Kyocera multicrystal photovoltaic modules have passed the following tests. 0 Thermal cycling test • Thermal shock test • Thermal / Freezing and high humidity cycling test • Electrical isolation test • Hail impact test • Mechanical, wind and twist loading test • Salt mist test • Light and water -exposure test • Field exposure test LIMITED WARRANTY X 1 year limited warranty on material and workmanship X20 years limited warranty on power output: For detail, please refer to *category IV' in Warranty issued by Kyocera (Long term output warranty shall warrant if PV Modules) exhibits power output of less than 90% of the original minimum rated power specified at the time of sale within 10 years and less than 00% within 20 years after the date of sale to the Customer. The power output values shall be those measured under Kyocera's standard measurement conditions. Regarding the warranty conditions in detail, please refer to Warranty issued by Kyocera) ELECTRICAL CHARACTERISTICS Current -Voltage characteristics of Photovoltaic Current -Voltage characteristics of Photovoltaic Module KC200GT at various cell temperatures Module KC200GT at various irradiance levels voltage rV) I voltage rV) DC Input Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Recommended PV power 3000 - 5000 Wp 4000 - 6300 Wp 3600 - 5500 Wp Max. DC input voltage 500 V 500 V 500 V Operating DC voltage range 150 - 450 V 150 - 450 V 150 - 450 V Max. usable DC input current 26.1 A 33.2 A 29.3 A AC Output Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Maximum output power @400 C 4000 W 5100 W 4500 W Nominal AC output voltage 240 V 208 V Utility AC voltage range 212 - 264 V (240 V +10%/-12%) 183 - 227 V Maximum AC current 16.7 A 21.3 A 21.6 A Maximum utility back feed current 0.0 A 0.0 A 0.0 A Operating frequency range 59.3 - 60.5 Hz (60 Hz nom) Total harmonic distortion <5% Power Factor (cos phi) 1 General Data FRONIUS IG 4000 FRONIUS IG 5100 FRONIUS IG 4500 -LV Max. efficiency 95.2% 95.2 % .94.4% Consumption in stand-by < 0.15 W (night) Consumption during operation 15 W Enclosure NEMA 3R Size (Ixwxh) 28.4 x 16.5 x 8.8 in (720 x 418 x 223 mm) Weight ` 42 lbs. (19 kg) Ambient temperature range -5 to 122 °F (-20 to +50 °C) Cooling controlled forced ventilation Integrated DC and AC disconnects standard UL approved DC & AC disconnects Protections Ground fault protection Internal GFDI, in accordance with UL 1741 DC reverse polarity protection Internal diode Islanding protection Internal, in accordance with UL 1741, IEEE 1547 Over temperature Output power derating Surge Protection Internal DC & AC protection, Tested to 6 kV Compliance Safety UL 1741 EMI FCC Part 15; Class A & B Anti-Islanding protection UL 1741, IEEE 1547 Ground fault detector and interrupter Compliant with NEC Art. 690 requirements, UL 1741 Miscellaneous Maximum AC over current protection Two -pole, 30 A circuit breaker AC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire DC wire sizing Use maximum AWG 6 194°F (90 °C) copper wire AC disconnect 32 A DC disconnect 40 A Warranty 10 year Premium Warranty is Standard Distributed by D0 nius Fronius USA LLC A o Solar Electronic Division 10421 Citation Drive Suite 1100 Brighton, Mi 48116 Phone: 81 -Q -Z20 =4 14 Fax:'81 COUNTY E -Mail: ueEPARTM ENT a 00'a APPROVE® FRONIUS`�ICG L_ -- ■ GRID -TIED INVERTERS FOR PHOTOVOLTAIC SYSTEMS Light Weight At 42 lbs, the FRONIUS IG inverters are the lightest grid -connected inverters making them both easy and cost-effective to install. More Energy MIXT"" Concept allows your system to output more energy under part -load conditions. Lower Cost Integrated UL approved DC & AC disconnects which reduce installation time and complexity - often eliminating the need for additional disconnects. LCD Display User-friendly and comes standard with every FRONIUS IG; tracks more than 20 critical system performance parameters. Powerful At 4000, 4500 and 5100 watts, these inverters deliver more power output for higher performance installations. Reliable Fronius has been in business for over 60 years and has more than 200,000 FRONIUS IG inverters installed worldwide. Warranty 10 year Premium Warranty. (zt L:7 POWERING YOUR FUTURE a r �� 5 rid �� ■ GRID -TIED INVERTERS FOR PHOTOVOLTAIC SYSTEMS Light Weight At 42 lbs, the FRONIUS IG inverters are the lightest grid -connected inverters making them both easy and cost-effective to install. More Energy MIXT"" Concept allows your system to output more energy under part -load conditions. Lower Cost Integrated UL approved DC & AC disconnects which reduce installation time and complexity - often eliminating the need for additional disconnects. LCD Display User-friendly and comes standard with every FRONIUS IG; tracks more than 20 critical system performance parameters. Powerful At 4000, 4500 and 5100 watts, these inverters deliver more power output for higher performance installations. Reliable Fronius has been in business for over 60 years and has more than 200,000 FRONIUS IG inverters installed worldwide. Warranty 10 year Premium Warranty. (zt L:7 POWERING YOUR FUTURE 't At A� r C16 V v 50 CHANNEL NUTS & HARDWARE __.:; . ............ RESISTANCE TO SLIP -With Safety Factor of 3 00 COOPER B -Line i Thread U P I N .1, ni s, �u 'ber 1�' ga., C hannel _kesjstancc.to 14 Cl6n Slip n el 16 ji. channel #8-32 N221, N221WO,N521 50 N. -.-l'. 220 'Jm' 50 220 Ibs. so N 220 N721,TN221 # 10.-24 :..N222. N222WO N522 - ... - - .. ... . .:$ .. . . . ..100 I . . 40 P r .. 'N722, IN222 .0 10-32 N227, N227WO, N527 100 440 100 440 100 440 N727, TN227 ... ..... 1/4 '...,.FN224 N2;4,N�24wq..N5;4, N724 �300 . :..1330:;':::..::::300-:; -1 33 ::.�OQ `1330 TN224, BFN-4,'BMS-6,*BMT 6 8 N223, N223WO, N523, N723, TN723 450 2000 450 2000 450 2000 BFN-8, BMS -8, BMT -8 Nit 16 A;��W . 29, 'N728, so 3560 6 0 :.'600 "228, M-10, BMS -10, BlVff-10 7/16"-14 11'226, N226WO, N526 1000 4450 800 3560 800 3560 N726, TN226 `":T122S BMS-D-12,'BMT.D.12 .1500... N525,'N525WO, TN525, BMS -12, BMT -12 ?1500 -'6670 :...IOOD N255, N255WO, N755, TN255 1500 6670 1000 4450 1000 4450 4450 N555, N555WO 1500 6670 1000 4450 1000 N275.' N275WO, N775 1500 6670 1000 :4450 - :-4450 -:4450 :"N575,N575WO `1500 "'6670 4,000 507 7/8-4 N278, N278WO, N778 1500 6670 1 1000 4450 1000 1 4450 Resistance to Slip of Channel Nut Reference page 44 for general fitting and standard finish specifications. J (n-) y E �_U) CHANNEL NUTS & HARD WARE COOPER B-Line ..�CTTi4vA.>.tSNI•W�VxTw...:.:<....i+vc...... ... ... ... PULL-OUT STRENGTH •With Safety Factor of 3 -Maximum pullout strength for B 1 I & B 12 channels is limited to 1500 lbs. (6670 N). Pull -Out Strength of Channel Nut P Reference page 44 for general fitting and standard finish specifications. 41 0 118-32 N221, N221 W0,N521 200 890 200 890 200 890 N721,TN221 #10-24 : N222,N222W0,N522 250 1110 250 ' :.1110..,. 250. 1,110 fN722, TN222 " '`' #10-32 N227, N227WO, N527 250 1110 250 1110 250 1110 N7279 TN227 1/4"-20 FN224,1V224,N224W0, N524, N724, 450 2000 :1450 :' '.2000 :: 450. ' • :2000 TN224, BFN-6, BMS -6, BMT 6 .'. .: "' , S/ia„ 18 N223, N223W0, N523, N723, TN723 BFN-8, BMS -8, BMT -8 750 3330 750 3330 750 3330 3/8"-16 FN228, N228, N228W0, N528, N728, TN228, BFN-10, BMS -10, BMT -10 1100 4890 1000 .4450 ' .']000.::." 4450 7/ie"-14 N226, N226WO, N526 1500 6670 1200 5340 1000 4450 N726, TN226 :: N225,.N225W0, N725, TN225, ;• t/2"-13 "BMS -D,12, BMT D -l2 2000.: 8900 ... :1400. ; : ' ::.6230. ": ;' .1000 .:: ..4450 N525, N525WO, TN525, BMS -12, BMT 12 1500 6670 1400 6230 1000. ' ' 4450 N255, N255WO, N755, TN255 2000 8900 1400 6230 1000 4450 6670 1400 6230 1000 4450 N555, N555WO 1500 3/4"-10 N275, N275WO, N775 2000 8900 1400 6230 " 1000 "' 4450 6670 1400 "6230 1000 4450 " N575, N575WO 1500 7/8"-9 N278, N278WO, N778 1500 6670 1400 6230 1000 4450 Pull -Out Strength of Channel Nut P Reference page 44 for general fitting and standard finish specifications. 41 CHANNEL SELECTION CHART for Channels, Materials and Hole Patterns I® COOPER B -Line The selection has been prepared to provide a reference for available channel, materials and hole patterns. Material types available for various hole patterns are defined by numbers j thru q.. Some stainless steel channels with hole patterns are available on special order only. *Metric equivalent for thicknesses shown in chart. ••j - Steel 12 Ga. = 2.6 mm 18 Ga. = 1.2 mm • Aluminum 14 Ga. = 1.9 mm .105 = 2.6 min 3 - Type 304 Stainless Stec] 16 Ga. = 1.5 min .080 = 2.0 mm 4 - Type 316 Stainless Steel Properties may vary due to commercial tolerances of the material 'C11 ty ! w,< a D4 'c�Ea a e: VJ ' T BK style channel available in four (4) channel sizes and one([) hole pattern only. (Example BK221-1112) Reference page 14 for general fitting and standard finish specifications. 15 BITE COUNTY BUILDING DEPARTMENT s APPROVED Channel Part Numbering Example: 4 220 Channel Typc Role Patterns Material/Finish Length B11 Sli (pg. 40) GRN 120 B12 S(pg.40) GALV 240 B22 t H178 (pg. 40) HDG B24 t TH (pg.41) YZN B26 K06 (pg. 4 t) SS4 B32 SHA (pg.41) SS6 B42 S58 (pg. 42) AL B52 t M (pg. 42) B54 t 1-125 (pg. 43) B56 1-1112 t (pg. 42) B62 Leave blank for no hole pattern B72 E7016 'C11 ty ! w,< a D4 'c�Ea a e: VJ ' T BK style channel available in four (4) channel sizes and one([) hole pattern only. (Example BK221-1112) Reference page 14 for general fitting and standard finish specifications. 15 BITE COUNTY BUILDING DEPARTMENT s APPROVED 20 B22 CHANNEL B22 -Thickness: 12 Gauge (2.6 mm) •Standard lengths: 10' (3.05 m) & 20' (6.09 m) -Standard finishes: Plain, Dura -Green, Prc-Galvanized, Hot -Dipped Galvanized, Stainless Steel Type 304 or 316, Aluminum -Weight: 1.90 Lbs./Ft. (2.83 kg/m) SECTION PROPERTIES 00 COOPER B -Line 15/8" 3/8+, (41.3) 3/8+• (9.5) (9.5) 7/8„ (22.2) 9/32" Y - '1 (7.1) 15/8" X X (41.3) 7252 (18.4) I 13/16" (20.6) B22 1.910 1 (2.84) 1 .562 1 (3.62).1912 (7.96) .2125 (3.48) .583 (1.48)2399 (9.99) .2953 (4.84) .653 (1.66) B22A 3.820 (5.69) 1.124 (7.25) .9732 (40.51) .5989 (9.81) 931 (2.36) .4798 (19.97) .5905 (9.68) .653 (1.66) B22X 6.649 (9.89) 1.956 (12.62) 4.1484 (172.67) 1.7019 (27.89) 1.456 (3.70) 11,10231(45.88)l1.2027 (19.71) .751 1 (1.91) Calculations of section properties are based on metal thicknesses as determined by the AISI Cold -Formed Steel Design ?Manual. B22A Wt. 3.80 Lbs./Ft. (5.65 kg/m) Reference page 14 for general fitting and standard finish specifications. (4113) 31/4" x,H (82.5) 13/1 (20.6) 15/s" (41.3) ) t Or , 11 B22 BEAM LOADING DATA WAR B -Line Based on simple beam condition using an allowable design stress of 25,000 psi (172 1\41'a) in accordance with NVIVIA, with adequate lateral bracing (see page 11 for further explanation). Actual yield point of cold rolled steel is 42,000 psi. To determine concentrated load capacity at mid span, multiply uniform load by 0.5 and corresponding deflection by 0.8. *Failure determined by weld shear. 22 Reference page 14 for general fitting and standard finish specifications. E COUNTY BUILDING DEPAPTMA":NT APPR0VED B22 2610 (11610) 14 (.35) 261 (11610) 2610 (11610) 12 (305) B22A 2610* (11610) .002 (.05) 2610* (11610) 2610* (11610) B22X 5790* (25755) .001 .02) 5790* (25755) 5790* 25755) :. :.622 ` 2269.` : ;(10093)::: ''.031 :.' ::(.79) :; `:: :{10093) .' ;;:2269.:; :(10093) ' :. •18. `:.:' ::'(457). :. :.' B22A .. 2610* :; :;(1)610).: :007.:"," :.(.18) ;, .•2249. ,2610': ? ':,(116yo) :: ;2610• :; :(11610) '•:" `B22X 3790* 25755 :003 '' '' .07 5790• "' (25755) -5790' ` "'t25755) B22 1702 (7571) .056 (1.42) 1702 (7571) 1702 (7571) 24 (609) B22A 2610* (11610) .017 (.43) 2610• (11610) 2610• (11610) B22X 5790' 25755 .008 .20 5790• 25755 5790* (25755 22' .:,.:.' :.1361 '; ": ':;(60sa)• :. 087, :: ":(2,21) .: '"•1361 .:; :;(6054) ::; ::1294 ::: ;:(5756):. 30 ; " : ' (762) ." •: :B22A • 2610!" ': (1610) 033 .`:' •°:'(.84) ... '"2610! : `• .; :;2610•..'(11610) .: ~B22X 5790*,' 25755 '' '.017 ` 73 ' 5790* ,(11610) 5755 5790• ' "(25755) B22 1135 (5049) .126 (3.20) 1135 (5049) 899 (3999) 36 (914) B22A 2610• (11610) .057 (1.45) 2610• (11610) 2610* (11610) B22X 57904 (25755) .029 (.73) 5790• (25755) 5790• 25755) :... :.• ::B22 ::: '; :. .:Ed'(25755) ,;'(4323)..:.. :.:172 .° :(4.37) .; :972 :' .. `:(4323):'.'. ::660. `.`. •.(2936) '.:::42 .'? " :(1067).:. " ;.::B22A :.."... .2 '(11.6)0).;` ::091 ;_(2.31) ; :.261Q`•. •::''(11610) ::261.0.!::: ;(116]0)::; 'B22X 5' °:046 `' 1. 171 5790* " 25755 '57900 ' 125755 B22 851 (3785) .224 (5.69) 758 (3372) 505 (2246) 48 (1219) 822A 2405 (10698) .125 (3.17) 2405 (10698) 2405 (10698) B22X 5790* 25755 .068 1.73 5790' 25755 5790* 25755 1'B22 :. 756 ' : ::.`(3343) : ':.':284 ..': "'(7.2)) :: '.599 :(2664) :399 (17 5) .: "54. ::.., ()3�1} :, ; .:B22A ':' "• 2138. '.::(951.q) ,' ..)58.::: :(4.Q1) ;: :2138 {9510) :: `.2024 :{9003) B22X 5790• 25755 :097 "' 2.46 '° 5790* 125755 ' 5790' B22 681 (3029) .351 (8.91) 485 (2157) 323 (1437) 60 (1524) B22A 1924 (8558) .195 (4.95) 1924 (8558) 1640 (7295) B22X 5645 (25110) .130 (3.30) 5645 (25110) 5645 (25110) "B22 :. 619.:"; ;;:(2753)..:'' .::424::. :()0.77y ;:40) :.'' :(1784);'; •`::267 .`.::''•:(1187);' 66 :: `.: .(1676)..' • ':.."'B22A ..'•:.•. '' 1749 :; ;: (7780)..: . 236..:: . (5.49) •:• :.:7749: ; ';(7780) •::: :`]355 :: ° (6U27J B22X `5132 (22828 :' a 158: ' .01 5132 22828 :3132 22828 ' B22 567 (2522) .505 (12.83) 337 (1499) 225 (1001) 72 (1829) B22A 1603 (7130) .281 (7.14) 1603 (7130) 1139 (5066) B22X 4704 (20924) .188 (4.771 4704 (20924) 4704 20924 B22 :: 524 ";. :.(2331). `:593.'; .(15.06) : 287. ". 1(1276) "':: °;;(844),•: 78 • '. ' :(1981) ;: ; :'B22A • ':.': 1480 •:.: :::(6583) ':69'i :.,330.:: ;:(8.36) :`1455 ,(6472).' " .:.191'•'':.: :.`9.70 :': ::(4315) •': " 'B22X 4342 " : 14)'1 ':220 " (3,59 •4342 19314 4270 ' ` ( 18994 B22 486 (2162) .687 (17.45) 248 (1103) 165 (734) 84 (2133) B22A 1374 (6112) .383 (9.73) 1255 (5582) 837 (3723) B22X 4032 17935 .255 6.48 4032 (17935 3682 16378 :':..•: .: ::::B22::..:.:.• ':.(2019)':' :".789:: (20,04).: :.:'216.•::: :,(961) : :144.,'.:.. .::(640)':. B22A ; ':. •.1283 .; ; •: (509)• ; " : ::4.40 ' :':(11.17) .. ; :1093 ' ' ;; (4862) ' ; :'••.729::: :: (3243) ".. B22X 3763 ' )6738 :293 '' 7.44 3763 16736 3207 • 14265 822 425 (1890) .898 (22.81) 190 (845) 126 (560) 96 (2438) B22A 1202 (5347) .500 (12.70) 961 (4275) 640 (2847) B22X 3528 (15693) .334 8.48 3528 (15693) 2819 12539 :.: •: :.. :.B22 ..:.:'' . ' ' '.400 :(25.73) .' ,.;168 :.:: :: (747) ":: `112 '.:•' ' " (448) ..: ;(2591) .:' :::"B22A .:::.: :,`1132 ;; :.. :.'(5035): c .':.565 ::_:.:(14.35), :;851 ".:: ::(3785) ::: ?:567 `:'' `(2522) ; -B22X 3320 1a968 '.377 '(9.57 3320 ta768 2497• ' 11107 B22 378 (1681) 1.136 (28.85) 150 (667), 100 (445) 108 (2743) B22A 1069 (4755) .633 (16.08) 759 (3376) 506 (2251) B22X 3136 (13949) •422 (10.72) 3136 13949) 2227 9906 :....... :...:"• B22 :.358 "::: ';:(1592) `•., 1.266.;: :(32.15) :.. :134 ::';. -.•(596) B22A .: ' : •: ' :1013 ; .'(4506) :. :.7Q6 : (17.93) :• ; :681. . , '.(3029) '.; ':.454 . ' . (2019) .:.; B22X '2971 "' ''( 13215 :471^ 11.96 2971 •�13215 1999 -' 8892 B22 340 (1512) 1.403 (35.63) 121 (538) 81 (360) 120 (3048) B22A 962 (4279) .782 (19.86) 615 (2735) 410 (1824) B22X 2822 (12553) .521 (13.23) 2706 (12037) 1804 (8024) Based on simple beam condition using an allowable design stress of 25,000 psi (172 1\41'a) in accordance with NVIVIA, with adequate lateral bracing (see page 11 for further explanation). Actual yield point of cold rolled steel is 42,000 psi. To determine concentrated load capacity at mid span, multiply uniform load by 0.5 and corresponding deflection by 0.8. *Failure determined by weld shear. 22 Reference page 14 for general fitting and standard finish specifications. E COUNTY BUILDING DEPAPTMA":NT APPR0VED B22 COLUMN LOADING DATA coo B -Line raced Height. 'C.:, Style C. LoadingLUnb, Slot va ,:, -K - o.,, 1 B22 10454 (46502) 4276 (19120) 10598 (47142) 10222 (45470) 9950 (44260) 12 (305) B22A 21625 (96193) 7002 (31146) 21677 (96424) 21539 (95810) 21433 (95339) B22X 46948 208835 18975 (84405) 47061 (209338) 46761 208003 46531 20(,980 B22 •: ,. '9950.:: .(44260).' 4153 (18473)..; 10253 • .(45607) : 9481:: .:(42173): .8955 (39$34) 21433. .(95339) 6959: (30955) ... 21551. ;(95863) ? 21239.. (94476)':. 21001 ;(93417) 922X 46531 2069901 18859 (83899) 46787 •208119 46110 205107) 45593 (202808 B22 9311 (41417) 3993 (17762) 9801 (43597) 8582 (38174) 7801 (34700) 24 (609) B22A 21164 (94142) 6898 (30684) 21373 (95072) 20819 (92607) 20397 (90730) B22X 45947 (204382) 18693 (84440) 46401 (206402) 45198 (201051) 44282 196976) B22 .: :. 3582: .(38174)i 3802.. (16912) 9268 (41226) 7601.' ;' (33811) ; .6595• :(29336) 30 .:. :" (76.2).: ". `B22A `:< : 20819. .•(92607) :: 6821." '(30341):. 21145. (94057)..' 20279 :.',(90205) :. 19619 :(87269) :-.B22X '' 45198 201051 18485 82225 45906 '(204200) 44026 '195837 42593 189463 B22 7801 (34700) 3589 (15964) 8676 (38593) 6595 (28336) 5392 (23985) 36 (914) B22A 20397 (90730) 6728 (29927) 20866 (92816) 19619 (87269) 18669 (83044) B22X 44282 (196976) 18233 81104 45300 (201504) 42593 189463 40530 180286 B22 : .: `, `.6998. .:(31128) . 3360 '(14946) :8048 (35799) . .5595: :(24888 4444. ;(19768) 42 . ' : '(1067) .. ;':B22A `; ;19898.:, , (8$511) ; :.6.620. .1;29447) .: 20537. ,(91953) ' 18840 'A83804)].':I7546 :(78048) B22X " 43)98 192154 ' 17940 (79801) 44586 •'(198328 40901 (181937 38092 169441 B22 6193 (27548) 3118 (13869) 7401 (32921) 4718 (20987) 3791 (16863) 48 (1219) 1322A 19322 (85948) 6496 (28895) 20157 (89663) 17940 (79801) 16251 (72288) B22X 41948 186594) 17604 78306 43761 (194565) 38948r(701 35281 156938) .B22 .:: 5392 (2398s) . 2864. . (12740} 6746. :,(30008) ; 4090: 3310 - (14723) ,(1371) : B22A .18669 ' 1 (83044) 6263 (27859) . 19276 .'( .. 5) 1692Q.. 14782 " B22X 40530 (180286 16973 75499 42825 (190495 3673332092 ,(65753) (142752)' B22 4718 (20987) 2631 (11703) 6093 (27103) 36162936 (13060) 60 (1524) B22A 17940 (79801) 5340 (23753) 19244 (85601) 1578113141 (58454) B22X 38948 (173249) 14471 (64370) 41779 (185842) 34260 1 (152396) 28529 (1 26W " 222 .,' :4202 .• :(18691) , 2434 (1.9827) r :5441. .(24203) . 3242 ,(14421) .: 2634 (11716) : 66 (1676) $2ZA :17134..: '"(76216) . 4587 •(20404) : 18712 :..(83235). 1452) . (64592) ': 11328. •:(50389) B22X 37198 (165465 12431 (55296 40624 '180704 31525' 140230 ' 24593 (109395 B22 3791 (16863) 2264 (10071) 4869 (21658) 2936 (13060) 2381 (10591) 72 (1829) B22A 16251 (72288) 3968 (17650) 18129 (80642) 13141 (58454) 9524 (42365) B22X 35281 (156938) 10753 (47832) 39358 (175073) 28529 (126903) 20676 (91971) .:B22 :: .:,3456..:(15373). 2116. (9412) . .4412 ..:(19625) 2680.: :(11921) 2166. :(9635) 78 (1981) • B22A ..'.. :]5291. '(68018) :: 3456. (15373) . 17496 (77826) : 11642. :(51786) 8115 (36097) B22X "' 33197 147667 9366 41662 37984 168961 25275 (112429) 17617 •(78364 B22 3176 (14127) 1984 (8825) 4037 (17957) 2461 (10947) 1980 (8807) 84 (2133) B22A 14255 (63409) 3028 (13469) 16812 (74783) 10076 (44820) 6998 (31128) B22X 30947 137659) 8206 (36502) 36499 (162355) 21875 (97305) 15192 (67577 ;2936: '.(13060) .. 1867 ; (8305) :. 3,724 (165.65).; 2270.:. :(10097).: :(8078) . `90 ..(2286) .. .''B22A .`:; x13)4) :, 5(58454)•` 2667 • ;(11863).- 1607.7 .(715)4) :. 8778 , 1816. .:(39046)::, 6096. .(27116) `B22X '.28529(126903) 7227 32147 34903 155256 19057 84770 13234 58868 B22 2728 (16583) 1761 (7833) 3456 (15373) 2101 (9346) 1671 (7433) 96 (2438) B22A 11951 (53160) 2359 (10493) 15291 (68018) 7715 (34318) 5357 (23829) B22X 25945 (115409) 6393 (28437) 33197 (147667) 16749 (74503) 11630 (51733) '(23.9 " ".2545.°. {11321):, ?1664. (7402):: 3225 '(14345)., 1951: .".(8678).;.;. 1542'. ':(6343) ..:102 , :.: 1) .: ." B22A :' : ] 0678 .:'(47498) . 2093.: : {9310) 14455 `(64799) ; :683!1 "; (3Q399), ; :4746. ",(211.11) `.'B22k 23182 •"(103118) 5672 25230) ' 31382 " 139594 14836 ''(65994) 10303 (45830 B22 2381 (10591) 1575 (7006) 3022 (13442) 1816 (8078) 1426•" (68599) 108 (2743) B22A 9524 (42365) 1867 (8305) 13568 (60353) 6096 (27116) 4233 (18829) B22X 20676 91971 5059 22503 29456 131027 13234 58868 9190 40879 B22 '': ='°:..:2234 =` ".:(993.7) :. 1494 ' '(6645} :. 2842 " ;(12642) i694.; •:.(7535) :`.. 1322" •:(5880) 114. , {2895) •; ::B22A :8.548..: (38023) 1675 (7451) .12630.. '(56181), 5471 .` (24336) . 3799** (1 6899) B22X 18558 82550 4539 " ", 20190 27420 121970 11877 '"52831 8247 36684 B22 2101 (9346) 1418 (6307) 2680 (11921) 1583*' (7041) 1228** (5462) 120 (3048) B22A 7715 (34318) 1512 (6726) 11642 (51786) 4937 (21961) 3429** (15253) B22X 16749 (74503) 4097 (18224) 25275 (112429) 10718 (47676) 7444 (33112) **Where the slenderness ratio CSL exceeds 200, and K - end fixity factor, L - actual length and r = radius of gyration. Reference page 14 for general fitting and standard finish specifications. 23 b�o 40 CHANNEL HOLE PATTERNS WISH THRU B56SH SH TYPE CHANNEL -For beam loads use 90% of Channel Loading Chan B11SH B11S THRU B56S S TYPE CHANNEL -For beam loads use 90% of Channel Loading Chart B11S 12 Ga. (2.6) 31/4" (82.5) 2.97 (4.37) B12SH 12 Ga. (2.6) 27/16" (GI.9) 2.39 (3.51) B22SH :.: 12 Ga.' .:(2.6):I5�8"'.: 1,5J8" :•. ..(at,3y : .:1.82 (2:66) B24SH 14 Ga. - (1.9) 15/8" (41.3) 1.34 (1.99) B26SH 16 Ga. (1.5) 15/8" (41.3) 1.07 (1.59) B32SH 12 Ga. (2.6) 13/8" (34.9) 1.62 (2.41) B42SH..;: 12.Ga.: ;:(2,6) :,1".'" '(25.4)•: 1.36;.:::(2.02) (1.98) 1352SH 12 Ga. '(2.6) 13/16"--' :(20,6) '1.19 (1.77 B54SH 14 Ga. (1.9) 13116" (20.6) .91 (1.35) B56SH 16 Ga. (1.5) 13/16" (20.6) .80 (1.19) B11S THRU B56S S TYPE CHANNEL -For beam loads use 90% of Channel Loading Chart BlIH17/8 THRU B56H17/8 H17/8 TYPE CHANNEL -For beam loads use 90% of Channel Loading Chart B11S 12 Ga. (2.6) 31/4" (62.5) 2.94 (4.37) B12S 12 Ga. (2.6) 27/16" (G1.9} 2.36 (3.51) 132ZH17/8,• ; 12.pa. `12 Ga..(2,6) 'I S/ J 1,5J8" :•. ;(41:3) ..1,99..... (2:66) B24S 14 Ga. "(1.0) : •`15/a" :.(41.3):1 '.1.32 "'` (1.96) B26S 16 Ga. (1.5) 15/8" (41.3) 1.06 (1.58) B32S 12 Ga. (2.6) 13/8" (34.9) 1.59 (2.36) B42S. •:'.. 12 Ga .. ,(2.6)" : • ;'1':::; (25.d) ; ":1.33 :.. (1.98) B52S ° '' 12 Ga. (2.6) 1?/16". (20.6) 1.16 (1.72) B54S 14 Ga. (1.9) 13/16" (20.6) .89 0.32) B56S 16 Ga. 1 (1.5) 13/16" 1 (20.6) .79 (1.17) BlIH17/8 THRU B56H17/8 H17/8 TYPE CHANNEL -For beam loads use 90% of Channel Loading Chart 2 COOPER B -Line 9/16" X 11/8" SLOTS (14.3) (28.6) 17/8" (47.6) TYP. 9/16" DIA. HOLES (14.3) Reference page 14 for general fitting and standard finish specifications. BUTTE COUNTY BUILDING DEPARTMENT APPROVED B11H17/8 12 Ga. (2.6) 31/4" (82.5) 3.00 B12H17/8 12 Ga. (2.6) 27/16' (61.9) 2.42 132ZH17/8,• ; 12.pa. .(2,6), . 'I S/ J :(41.3) : `1.85.:: B24H17/8 • 14 Ga (1.9) 15/8' : (41:3)''-':1.16" :.'(2.02) B26H17/8 16 Ga. (1.5) 15/8" (41.3) 1.09 (1.62) B32H17/8 12 Ga. (2.6) 13/8" (34.9) 1.65 (2.45) B42P 7/8..: 12 GA. (2.6). ': ,1"...:: .(25,:4).: `1.39.:- .12.07) . 12 Ga. (2. (20.6) 1.22B52H17/8 B54H17/8 14 Ga. (1.9) 13/16' (20.6) .93 (1.38) B56H17/8 16 Ga. (1.5) 13/16" 1 (20.6) .82 (1.22) 2 COOPER B -Line 9/16" X 11/8" SLOTS (14.3) (28.6) 17/8" (47.6) TYP. 9/16" DIA. HOLES (14.3) Reference page 14 for general fitting and standard finish specifications. BUTTE COUNTY BUILDING DEPARTMENT APPROVED 900 ANGLE FITTINGS 00 COOPER B -Line B496 B496-1 B371-2 TWO HOLE ADJUSTABLE TWO HOLE ADJUSTABLE THREE HOLE ADJUSTABLE CORNER ANGLE CORNER ANGLE CORNER ANGLE -Standard finishes: ZN, GRN -Standard finishes: ZN, GRN, IM -Standard finishes: ZN, GRN -Wt./C 85 Lbs. (38.5 kg) -Wt./C 58 Lbs. (26.3 kg) -Wt./C 61 Lbs. (27.6 kg) 67/8" (174.6) (60.3) '9/16" x 29/16" SLOT (14.3) (65.1) 17/8„ (47.6) B 104SH THREE HOLE ADJUSTABLE CORNER ANGLE -Standard finishes: ZN, GRN -Wt./C 68 Lbs. (30.8 kg) 31/2„ 13/32, (10.3) 12318„ �.............. (60.3) f 47/8" (123.8) a 9/16" X 29/16" SLOT (14.3) (65.1) 17/8" (47.6) B461 TWO HOLE ADJUSTABLE CORNER ANGLE -Standard finishes: ZN, GRN -WI./C 87 Lbs. (39.4 kg) 31/2" (88.9) 1/2" (12.7) �N 9/16" X 29/16" SLOT ® / 1 9/16" X 29/I6" SLOT 41/8 (14,3) (65.1) 15/16" (33.3) 9/16" x 11/2" SLOT A, (14.3) (38.1) ,\`i n 25/8" "1 All -,(66.7) 37/8" (98.4) B112 FOUR HOLE ADJUSTABLE CORNER ANGLE -Standard finishes: ZN, GRN -Wt./C 180 Lbs. (81.6 kg) 21/4„ �• 9/16" x l 1/2" SLOT -(2) ' (14.3) (38.1) tet. 31/2 133/4" (88.9) 4" } (95.2) (101.6) .... •65/8„ _.. - B113 B109S FOUR HOLE ADJUSTABLE TWO HOLE TAPPED CORNER ANGLE CORNER ANGLE -Standard finishes: ZN, GRN -Standard finishes: ZN, GRN -Wt./C 256 Lbs. (116.1 kg) -Wt./C 33 Lbs. (14.9 kg) 9/16" x 11/2" SL07'•(2)33/4„ 5/16"-18 TAPPED (14.3) (38.1) (95.2)%: 17/8" 6„ 1 (47.6) 1 i (152.4). 85/8" i , (41.3) (219.1)'--- 17/8„ (47.6) Reference page 58 for general fitting and standar) finish specifications. B521 TWO HOLE BUS DUCT ANGLE -Standard finishes: ZN, GRN -Wt./C 37 Lbs. (16.8 kg) 1 /2" L' / , 17/8„ (12.7)1`'- j(47.6) 2" (50.8) S • , q ANGULAR FITTINGS B147 -B152 TWO HOLE OPEN ANGLE -Standard finishes: ZN, GRN l' G B243 -B253 FOUR HOLE OPEN ANGLE -Standard finishes: ZN, GRN 4„ 5) B162 -B165 TWO HOLE OPEN ANGLE -Standard finishes: ZN, GRN ...A (27.0) �' •... S i % 35/16„ ® / (84.1) COOPER B -Line (31 %/1.6,"1 (93.6) ® A 31/2" 88).9 ®® B322 -B332 TWO HOLE OPEN SHORT ANGLE -Standard finishes: ZN, GRN B154 TWO HOLE OPEN ANGLE •Standard finishes: ZN, GRN, SS4 •Wt,/C 58 Lbs. (26.3 kg) 3" I1/1G•• �. T70) (27.0) 5/16„ 458.7) B522 THREE HOLE 950 OPEN ANGLE FITTING -Standard finishes: ZN, GRN •Wt./C 54 Lbs. (24.5 kg) 17/g" (47,6) 1 5° 35/8" (92.0:� I �i I I• ?' A I5/8" (44.4y' ® j/ (41.3) ... i•. J B488 TWO HOLE LEG CONNECTION -Standard finishes: ZN, GRN -Wt./C 100 Lbs. (45.3 kg) 68 Reference page 58 for general fitting and standard finish specifications. . �LB`GV(��( �((�� `` jjJ� 7 " uBLxNG � -F Lill n l�� 1o� 6 I 4 - 200 m :6�0'ft •Ga,rd k '2Q(Yi �rtap(lv�st"gni C!� ;#Ce�fe ;ti.rY:ri ne Mea ow to Tut �I;Dr. Khvt 0 � 2QOQr9�N�YTEQ�_�r'7e��A s' RUMIANO 14031 HEIDE ROSE LANE CHICO, CA 95973 (530) 893-8007 5.02 KW PHOTOVOLTAIC ARRAY 24° FLUSH MOUNT ON COMP. SHINGLE ROOF (30) KYOCERA 20OW PV MODULES (1) FRONIUS IG 5100 (240VAC) SHEET INDEX SITE PLAN: A-0 COVER SHEET A-1 SITE PLAN STRUCTURAL: S-1 STRUCTURAL LAYOUT S-2 STRUCTURAL MOUNT ELECTRICAL E-1 SINGLE LINE BUFF COUIVTy BUILDIOG DEPARTFOEJyT APPROVED F a �� NtM��M NIgJQ PERMT suom ft A-0 2 1 �■IM .v .v ..�„ ra...�.�. S/oG ' G:�:�M� MOM/OIC41d��1A111R®OIO�MNd ORDMAD /1�mIMM�O/OwO�ol AMM/aL1 ACKERWAIM�IMAl,OAOIOOAOI MJ40�AOlOMIR.IORNMr1/1�w1110{RftMll� i:FMS~ MJJIMI CWAOLLTMT�M/MIMIA7M vwM�naM/ wuwxw�� 6 4 ;#Ce�fe ;ti.rY:ri ne Mea ow to Tut �I;Dr. Khvt 0 � 2QOQr9�N�YTEQ�_�r'7e��A s' RUMIANO 14031 HEIDE ROSE LANE CHICO, CA 95973 (530) 893-8007 5.02 KW PHOTOVOLTAIC ARRAY 24° FLUSH MOUNT ON COMP. SHINGLE ROOF (30) KYOCERA 20OW PV MODULES (1) FRONIUS IG 5100 (240VAC) SHEET INDEX SITE PLAN: A-0 COVER SHEET A-1 SITE PLAN STRUCTURAL: S-1 STRUCTURAL LAYOUT S-2 STRUCTURAL MOUNT ELECTRICAL E-1 SINGLE LINE BUFF COUIVTy BUILDIOG DEPARTFOEJyT APPROVED F a �� NtM��M NIgJQ PERMT suom ft A-0 2 1 �■IM .v .v - a 3 z ` LEGEND — — weopanum OOIlouraM 0 0MoMa - — - — - — - — - — - — - — - — F- ._._.------ _------ _____------ ------ ------ -----_ _________________ DRIVEWAY I W TO PL , I I i DRVEWAYLLJ Ac MVEKM c Z! / ascomNwr I I c gI / � 0 i. \ flDv I I / f 24W TO M W I / / REAR YARD Lu I •\ I 225 TO PL I I / I I / i g I ! e I WTOPL I i L._._._._._._._._._._._._._._._._._._._._._._._._._._._._....... ...... ...... ...... _._._._._._.-._._._._._._._._.J Bum COUNT Btu®ISG ®Epq _ Y R��ENT A # AP-pRo V,ED SCALE: 1" = 40' f4wA4 SPG cito 2D WWRM COURT wa�wwvAoa�ar��wwlaoa�s��ws�eoKrAio cnoo►a►.w„ SITE PLAN MCNATO, CA 99M MDGWAL �� FAPMOD �oOPE06 1 �IItN�MR NSM "IWO CA UC.f1590E9 VMN= URW.wewwa�wnlyjrm �w �w11�1�IftA0LL7MIt1��WM - �� O�� H/q!W . vwoMro w►Mw� o01if1alOnOtc PERW StX MTTAL A-1 ". .. a 4 3 Z 1 6 4 8 2 D .00 2"x6" RAFTERS ARE @ 24" O.C. 240 ROOF PITCH COMP. SHINGLE ROOF SHEATHING 1�� N we A AZDAU H: leo'' TILT: SCALE: 1/4" =1' PE 24 rCOMM v 8�� �ROro COURT sffic� NdVATO,G91D19 Mpdmy G UQ S16m omm i 4157857 a 4 .nor cr RESIDENCE VE T .ACK 0 1 O 6' 26'-42" t 4'-8" 18' 6' METER AC DISCONNECT INVERTER DC DISCONNECT D �o BME COUNTY 51' BUILDING DEPARfi&IN fA APPROVED �we+rwuww STRUCTURAL LAYOUT �� �IIM�M�t p1�MN M/q/q ooMnwloloc �TsueMrrrK S-1 2 6 14 v. 1�_ I " � SPECIFICATIONS KC 200 GT L: 56.2 W: 39.0 D: 1.4 40.7LBS E I 1 MODULE B22 FLASHING FLAT JACK \ T -CLIP \ s X 31/2" LAG �\ SCREW SETUP \ B22 1 AV 6" BUILDING DEPARTMENT APPROVED moi Zvi • I COMP. SHINGLE ROOF SHEATHING I" ' SCALE:1"=1' ------------------------------------------ BPOsoIAa o�.�.�.+.w..�.�.o�w,r.�►a►r�a�om.� ..o�usoorw�N.Oa...iomwo�sora«r, STRUCTURAL MOUNT NOVATO,CA94M AIOOwa�r� �oouawgoa�mamoi OfEl01�e �If11r1�R «�KM M/ql� so Ut fl/6�OB8 �..�.�. mm.�....�... 41bd637867 wAflNl/f�MO11v1101LrMingl�IfalrmoM �'� �fBlfll I1t�1�MM flH�fO/ epwSMMWLSAL Mw PEM 8t1B9Q AL S`2 OOffi1Rxmcft 5 4 9 E 1 E-1 ■ 1r ■� ■0 .v el FRONIUS RUMIANO 5.02KW oc ow IO 5100 CAO) MMI MODULES I 4 1 (�) (10) KYOCERA 2MG PV MODJLEB (N 8E�8 SQUARE o K3 &I GRID TIE D (1) FRONIUS 5100 (?A0) NVERTER FUSIBLE(30) X (177.2) X (4 A%) - 6023.S2W AC I LOCKABLE 5.1KiN INVERTER (to)KYOCERA20M PV MIODILEB (IN 30► 240 VAC ( I ( 1) 0 KYOCERA 2MGT PV MODULES � SERIES s POLE SOON UL #1741 z H9S1R KYOCERA KC200 GT MODULE: INTERNALACMC INXII.MTOSESCOOMWI MAXIMUM POWER 200 W 812 SARE OOPPER GROlBD p)gQp—CTg MAX POWER VOLTAGE: 28.3V OPEN CIRCUIT VOLTAGE: W -W 812 MIOIF2 of ml I=Re (1)BfOTHYYN,2 aR0I80 �MB1TOtiCIJtO POWER CURRENT: 7.81A MAX PO (2) 810 USE,2 COMUCTORS �. (2) 8f0 THWW2 CONDUCTORS t EMR CONDUIT SHORT CIRCUIT CURRENT. 8.21A j (1) 810 THW*2 GROUND EQLI UBU GROUND t EMT CONDUIT FRONIUS 5100 (M0) INVERTER: MAX DC NPUT: MV c MAX AC OUTPUT CURRENT: 21.3A PEAK EFFICMVY: 34.6IL (10) SERIES MODULES x (S) STRINGS: (� s10 TFMIIKZ ooNDUCTORs TOTAL OPCIRCUl T VOLTAGE 3'20 VOLTS EN (1) N THWN.Z GROUND GEC B4T TOMAL MAX POWER VOLTAGE: 283 VOLTS TOTAL SHORT CIRCUIT CURRENT: 24.53 AMPS NlOIMIi TOTAL MAX POWER CURREN 1: 22AS AMPS AC MAX OUTPUT tX«RRBR: pM) NRENr 21:2A 21.6AX 1.26 = 2LM RATED AMPS NOTE THE ABOVE LABEL IS TO BE PLACE AT THE MEANS PER NEC CODE S00M ■ATOIIIM MTEII VOLTA0I0m METER (OPEN CUItC T VOL.TAG XIM(MV COR■>eCMIQ �(1Sx1.1>fj � 171.77 VOC B 200 AMP MAIN AC DISC BREAKER CUTLER HAMMER NON FUSIBLE (2)810 THWW2 CONDUCTOR= LOCKABLE 2pOLF ,)86 THWNF2 GROUID GEC 30A PEW 2 POLE 240V 200AMP Da 221URB ENCURE, BUTTE EC AC DlsooNNT LOCATED WRIIN 1aFT of MAN SERVICE COUNTY A POINT OFCON ECTIOX THEOUMITOFA BUILDING DEPARTMENT PwroVOLTAIC FOWER SOURCE SI4ALL SE C0104C11DABN090.8IWORft APPROVED PG SPO SOUR ao�sle�n�eww�Nornnw woaw DATE OESptl.fl011 IN QlD 61 SINGLE LEVERONI couar!!� �m�AN� LINE �w N1�M Ml"to NOVATO, CA 94M ao�wt�a �t� Imp mtvl meo oi�ow6= SO�i4R ���. M54583-7657 �. a. wn�llwworv�aarrnwamwmmw awSS01Ml 111DII�MM nlq/m arw�awA�nKaw�w�a PEFMT SUBWTTAL aoNnwlaaarc a 4 a 2 � E-1 ■ 1r ■� ■0 .v "7w ter - s 047-320-061 00-3063 RECK, RAE JEAN 14031 HEIDI ROSE LN, CHICO CONTR: ARTIC AIR CHANGE OUT HVAC 6 cfl 61-1 COUNTY OFBUTTE - DEPARTMENT OF.iDEVELOPMENT SERVICES - BUILDINC*DIVLSION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541..PERMIT N0. (Rev. 12/96) APPLICATION AND PERMIT C, ASSESSOR PARCEL NUMBER ri(0-3PO--rel ZONING BUILDING PERMIT OWNER �,v/ 1 goo TO`-/?�L.�L.S.J� SO. FT. OCC. BUILDING VALUATION �, ��4R"/[�/Il �NERS MAILItJG~ADD C !1-� C� ,CO//]]NTRAGTOI/R''Sr��/NO.A�ME /r �. �I,/ 4�j 111 �� HONE �� CONTRACTORS 5 IIJNO ADDRESS�:�.�C� •, .� G rll5� 9 Ili J'� CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS - Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filen Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS l qo 3/ .,,.j��l� �r/' , , / ,. �_ Energy Plan Checking Fee $ (• Off' PERMIT FEE S LAT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.0023.00 USEOFSTRUCTURE SF`lf Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat um water heater Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK Other ❑ New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation (MC Describe Work: ii i14 l/i` i Gas piping system 1 - 5 outlets 15.00 Buildingsewer 15.00 Mobile Home S G W 920.00 r PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 Main Service zo AOR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. �, '% / License Class . (i Lic. No. \ c 1 "ff f OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is Issued. ❑ I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is Issued. My workers' 24 compensation, insurance carrier and policy number are: Carrier I%C tlVI � _ _, Policy Number � -RA/� `6,-,a i (The above sections need not be completed If the permit is for work of a valuation of one hundred dollars ($100) or less.) [31 certify that in the performance of the work for which this permit is issued, I shall not employ any person In any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions ' c,r� /g- ^ X ✓j � '%✓/.1. % d- C Date � `_ _ (f Signature'of Applicant - ❑ Owner 40 -,Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. DWEUUNG OCCUP. 3 Soso. AC..BILDS. FT• N ADDNS.. ( M NON-RESID. @7.50 POWER APPARATUS a SINGLE 011rLEr CIR. OUTLET OR FORUREs Ex, Occup. BAL p I: o Ex. Occup. ourtEEDTs R IES D.OEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Filing Fee 20.00 Heating 1,7,5w 15,00 Cooling 25 •ou Hood 6.50 Ventilation PERMIT FE15 $404)0 Mobile Home Installation Fee $ Energy Inspection Fee $ a Occ �'.3 coNST. TYPE atii... TOTAL FEE $�.L1Q HAZ. D. FEES• "IMP ry,r FLOOD COF PARCEL PD HD ISSUE, ✓ This permit is hereby Issued under the applicable provisions the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. BdmlQl D Date . �i :�8 CIU y PERMIT EXPIRES ON Date rReceipt No.nR % +. -' 1 WHITED.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT �a COUNTY QF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 T N � �h_1 (Rev. 12/96) APPLICATION AND PERMIT ASSESSORPARCEL NUMBZONING �- 3a C) - BUILDING PERMIT OWNER E HO 3 ''��„ SO. FT. OCC. BUILDING VALUATION /PWER`Sg DRE •CONTRA 'S ME ♦ TELEPHONE isq 5-333 a CONTRACTOR'S MAILING ADDRES e P 59d 9 CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS 0l3 &�_Xs, Energy Plan Checking Fee $ PERMIT FEE $ LOT NO. SUBDNISIONSNAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SFX Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: obafyv PAPvac Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W (9]20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.00 Main Service zo..OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license iS •n full force and effect. ? License ClassLic. No. 2 3 U 9 I J OWNER -BUILDER DEC AR TION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service z TO tOooA 46.00so NEW CONST. owEwNo occuP. EU ( NRA 3.5¢F°. cons . MUL�TcoS. NON RESID. 97.50 POWER APPARATus 8 SINGLE OUTLET CIR. EX. Occup. OUTLET OR FIXTURES .00 BAL 20 ®I.SU Ex. Occup. OuT�rs Ra10°� 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 723.00 EEI PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers; 'orrpensato? U durance carrier and policy number are: Carrier ���/N� _ �,,,, _ Policy Number (rhe above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthw't omply with those provisi om:ply with tthose provisl/� O'er �O X Date Signature of Applicant - ❑ Owner ontractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating �00 25.O() Cooling CO .il00 Hood 1 6.50 Ventilation PERMIT FEt $ (� Mobile Home Installation Fee $ Energy Inspection Fee $ Qo yOAM& TYPE TOTAL FEE $Q.(� HAz. D FE a FLooO cOF PARCEL PD HD Issu This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicate above for which fees have been paid. By Date Aa A?_Co PERMIT EXPIRES ON Date Receipt No. 3 WHITE•D.D.S.•B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROO•APPLICANT Contractor's License # 234913 ARTIC AIRE HEATING • AIR CONDITIONING • REFRIGERATION RESIDENTIAL • COMMERCIAL • INDUSTRIAL SERVING THE NORTH VALLEY SINCE 1960 ��11 l�Uw,h„� lamas ovu*of� 2a --doh 12,)Ze) m fLA1 1 Wrni+s 2838 HIGHWAY 32 0 CHICO, CALIFORNIA 95926 0 (916) 895-3330 RESIDENTIAL 047-320-061 PERMIT#95-0471 CRESPO, Raffael 14031 Heidirose Ln., Chico Cont; Frank Koulczyk New Single,FaTRi,l.y '71 -Z, . ...... OFFICE COPY Address GAS t Meter By Date ELECTRI Meter By Da rl JOBFINALED(D Signature 'J OK O = Not OK Not Applicable Not Ready RESIDENTIAL (Single = Date U NDJERFLOOR (Plans) OK except N'sn i 1 Datt Zoning -Setbacks -Easements -Flood -Slope o Ftg., Main; Soils-Elec. Grnd.-/ /' Ftg. Depth Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; el -Wrapped s -Fireplace Ftg.-Steel D.W Fall -Fitting -Test -2 Way C/O -Sewer Test F. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. EI fldc; Underground r Pi hums & Ducts; Clearance -Material -Support -Ins. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 i Date Card B-1 Date Card B-1 Date PLU ING (Permit),OK except ft's Water Htr.: Vent -Access -Combustion Air -Baffle -------------------- ------------------------------- 1 a er Pipe; Test & Anchor -Nail Protection --- ------- ----------------------------------- 1V.: Test -Fittings & Anchor -Nail Protection Pr Pan; Test, First Floor -Tub Access ----- --- ---- est Tub & Shower, Second Floor -Tub Access -------------------- ------ ----------- 21. -Pipe; Size & Anchors Date _ _ Card B-1 — Date — Card B_1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except k's & Transformer Clearance -Ins. Protection a3--riec. Receptacles Spacing -Lights & Switches at Doors . i ---------- --------------------------------------------------------- ze Boxes & No. of Conductors -Stapled ----------- - 25 mex Installed Close .to Edge of Studs & C.J. -------- — '-------------------------------- ----- ----------- quip. Ground made up w/Mech. Fastners-Bond Gas & Water ----- -- --------------------------------------------------------------- ,24-2—Appliance Circuts in Kitchen & Conductor Size/GFI ---------------------------------------------------- 3,a�weed Wire Size i r ga. Cu or AI-A.C. Wire Size ! 1 ga. ------ ---- - Cu or At A . Range Circ. ! ga. Cu or AI -Oven Circ. / / ga. Cu or Al. I sulated Neutral Cl Yes ❑ No ------------------ -- - --------------- S vice -Riser Conductors & Ground -Main Disconnect ------------- --------------------------------------------------------------- E uip. Clearances Panels-Motors-Mech. Equip. lo s Closet Light -Shower Light -Spa Light - - ------------------------- ---------------------- oke Detector - -------------- ------------------------------------------------------ Date Card B_1 Date - Card B_1 ---------------------------------------- - - - Date Card B-1 Date Card -B-1 Date MECHANICAL (Permit) OK except a's A.C. Ducts Insulation & S_upport 3 ent Fan Exhaust above insulation - 49 C ndensaI Drain & Overflow: Size & Grade - A-Z_,rr ance-Vent: Access-Comb'Air-Return Air Vent -115 out j� - Access & Platform - Fu------ in Attic --------------------------------------------------------------------------------- Date Card B_1 Date Card B-1 --------- ------------------------------- Date Card B-1 Date Card B-1 Date FR G (Plans) OK except 4's 9. S' . Proper Material & Anchors - - W --------------------------- Studs-Nailing.Spacing & Bracing -Plates -Sound 4 B rin Walls over Girders & Floor Nailing -- - - - - -- 9 ---------------------------------------------------------- 4 ---------------------------------------------------- 4 Dr It Stop in Walls (rat proof) ------------ ---- -- ----------------------------------------------------------- 43. it Stops: Furred Ceilings -Stairs -Chases -Tub ------------------------------------------------- —--------------- eaders & Beam -Size & Bearing & Duplex) FRAMING (Continued) angers -Post Caps -Anchors -Connectors In Joist-R1tr. ties-Purlin—roof Brac-Truss-Shthn - fng pplace Ties or Type A Flue-Firepla Throa Barance ccess; Size & Romex Protection -Draft Stop -Ins. Baffles Arm. Windows or Exiting Doors -Sill Hgt. & Dimensions 51(1'G rage Fire Protection Framing — erty Line Firewall & Openings _ rf1 �E' t. Doors -One 3' -Check Garage -3rd Story, 2 Exits -------- .SSS lairs; Width -Headroom -Rise -Run -Landing -Fire Protection plywood on Roof Overhang -Attic Vents -Rafter Outriggers ---------------- — — Siding -Nailing Veneer OWGIazing tucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Area -Glass Protection -Skylights -Plastic .hear Walls: Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows DateCard B-1 Date Card B-1 ------------------------ -- -- Date Card B-1 Date Card B-1 Date FINAL lans) OK except ft's 64"—Ext. Steps -Door & Sidelight Protection -Landings - 6_ Smoke Detector Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor -Ducts -Meeh. Protection ------------ - - ------ 64. Te�room Exiting ------------------ G.F.I. & Bath Fixtures & Tub Access -Spa ---------- - ------- �66. Elec. Trim & Subpanel; Breaker Sizes & Labels airs & Rails ------------i-___`__placer- -- ------------- — i'or Stove: Clearances -Hearth Outlets at Wood Panel; Int. & Ext. ------------- --------------------------- 7 it.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance let. Outlets & Receptacles at Kit. Counter ----------- ----------------------------- ,7 . arage Fire Door: Swing -Landing -Closer A.C. D ct in Garage -Damper -------- -- tr. Htr -Vents-Clearance-Comb. Air-Connector-P.R.V. ----------------------- In Garage: Above Floor -Meth. Protection ---------------------------- - Ib.. Elec. & Mech. Equip. Listed for Location -------------- r ---- --------- --- ) ec. Receptacles in Garage: (G.F.I. Romex Protection nsulation-Foam-Looked in Attic ❑ Yes ------------- ---------------------------- -- �dJrd Rails & Deck Construction -Post Caps ---------------------------------------- - Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes ollowing instld.: Drive ❑ No; Walks 2'Tes ❑ No; _ PI ters ❑ Yes ❑ No � f S Brown -Finish ---- 2Fs A. nit: Disconnect. Electrical, Plumbing -- - - ----- - -— Vents Above Roof; Plbg.-Appliance-Fireplace.-Clearance to — Openings - - Wa _ ell: Disconnect, Electrical, Plumbing --- Ext or Elec. Trim; G.F.I. Receptacle -Underground — — Ventilation Throughout House - -- - e . Gla ---; rotection------------------------ ----- ------------------— _rrections from Previous Inspections W�lrst-Meters Tagged; Gas -Electric ---& Sewer Connected -C/O to Grade -HD Approval -Compliance Certificate_Other Certificates -- ------- --------------------------------- Date -------------------------------Date Card B-1 Date Card B-1 -- -- — ------------------------------- --- ----- Date Card -8- I --------_--Date_ Card B-1 _ Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES - BUILDIN (VISION 7 County Center Drive - Oroville, Cdilifornie '95965 - Telephone (916) -7541 PERMIT NO. APPLICATION AND PERMIT `'021 ASSESSOR PARCEL NUMBER 'ZONING SR1 BUILDI G PERMIT OWNER TELEPHONE .SQ. FT. OCC. BUILDING VALUATION 2780 i R 150 120.00 OWNERS MAILING ADDRESS 1687 FILBERT AVE CHICO 95926 506 M 9,108.00 CONTRACTOR'S NAME 916 FRANK K011T.CZYKCONTRACTORS 4 TELEPHNE 823 COV 10 699.00 MAILING ADDRESS --15728 THIEL WAY, GRASS VALLEY 95949 Fireplace M 2,500.00 CONSTRUCTION LENDER UNKNOWN Total Valuation Is 172,427.00 Filing Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 895.00 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 581.75 Energy Plan Checking Fee $ 23.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDINGADDRESS 14031 HEIDI ROSE CHICO PERMITFEE $ 1519.75 PLUMBING PERMIT Filing Fee 20.00 Each Trap 1 7.00 119. 0 LOT No. SUBDIVISIONS NAME PARCEL MAP Solar Or heat pump water heater 23.00 USE OF STRUCTURE SFjg Duplex ❑ Mobilehome ❑ Other SPECIFY Water piping 15.00 15.0 Each gas water heater or vent 15.00 15.0 Gas piping system 1 - 5 outlets 15.00 15.0 Building sewer 15.00 15.0( TYPE OF WORK NewXM Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work3 BDRM, Mobile Home I S I GI W 1 920.00 PERMITFEE g 0 Contractor ELECTRICAL PERMIT Filino Fee 20.'00 Main Service EOOV OR LESS ( 200A OR LESS ) 23.00 Main Service ( 200A To I000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is iII force and effect. -� r, .'�� �� %7/ License Class n Lic. No. ` OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. N 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. OR ADDNS. 8 ACC. BIDS. ) P. 3.5Q FT.119-15 NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 POWER APPARATTLET sUS ) & SINGLE OUR. Ex. Occup. ( OUTLET OR FIXTURES) 20 Q 1.00 BAL .SO Ex. Occup. oFIXEDTs (RESID.) ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 158-15 Contractor WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑' I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensatiinsurance carrier and policy number are: Carrier S I A P91icy Number 3 W 7 - ,S (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comp) with t se pr visions. 2 X ��'i�2P? - -- Date=4zzJ! _- Signature of Applicant - ❑ Own Contractor ❑ Agen An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling 29-n Hood510N 6.50 6-90 Ventilation PERMITFEE $ 89 00 Contractor Mobile Home Installation Fee $ Energy Inspection Fee $ OU -- occ R3 CONST. TYPE VN TOTAL FEE $ 2011.90 HAZJ D. FEES IMP - V�j All C F PICEL X PD HD ISSUE _ This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. N s' BY I&C ate �7 PERMITEXPIRESON (Date R celptNo. 0 9 % I WHITE-D.D.S.•B.D. C ARY-ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT FM " COUNTY OF BUTTE x' BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 5387541, -;), 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE 0 NER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when* correction of work is completed. If you have any questions pertaining to this matter, or need -ad ditional explanation please contact this office immediately. .I-- Date j REV 10/92 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contept this office immediately. RCv I VIJL cos ION CERTIFICATE � V\1 i- LA . t COUNTY h �- SUBDIVISON LOT NUMBER DESCRIPTION OF 1NUALLATION ROOF MATERIAL BRAND NAMR _ e 'CII1C1cNRSSZincheej TORRM41• !tR$1.tiTANGNZt4-VAl*uR —' COILING -" BATTS or BLANKET TYPE BATTS RAND DAMN CERTAINTBEp THICKNESS(inches) (" THERMAL RES ISTANCS(R-VALUE) 1.00SR FILL. TYPE F B • USS ". BRAND NAME INSULSAFE III CONTRACTOR'S MIN INSTALLED VT • lb MINIMi11I THICKNESS ' �� " INCHES MANUFACTURER'S INSTALLED WT )'SR 8Q FT ACHRIVR THERMAL R -K -S- CANCII R -r 1.U6) R-� 19XTERIOR WALL "ATERIAtt. FIBERGLASS 'BRAND NAME_ CERTAINTEED TNICKNESS(inches) i' — 'THERMAL RESISTANCE(R VALUE) R- RAISED FLOOR NATERIAL —BRAND NAME CERTAINTEED" TIICIKNRSS(inchee) THERMAL RES 1$TANCE(R-VALUE) SLAB FLOOR MATERIAL BRAND NAME _ THICKNESS inches THERMAL. RESISTANCE R-VA1.UK) --- WIDTH(inches) --- --- FOUNDATION WALL MATERIAL -_-BRAND RAMP. THICKNESS nc hes THERMAL RgSI.RTANCE(R-VAL'Ugj-'- - DECLARATION I hereby certify that the above insulation was installed In the building at -the above location in confoMaice with the Current Building Energy Standards for new residential buildings cobtBioeo.in title 24 of the California Adminstrattve Code. General Contractor Bu er License NumTiex Signature- and Title Date MWKINS+INDUSTRIES� �IN.C. 622184 5-Contractocc5sulat on Ad R er cens-e -- -SECRETARY _��— ��— Si iattire .and T tle Date I�v'r�Ht-riti>tr w7� W- COUNTYOF BUTTE - DEPARTMENTOF;i!E F , LO -DEPARTMENT - BUI INC DIVISION � µ 7COUNTY CENTER DRIVE -OROVILL'E,CALIFORNIA95965-TELEPH� (916r531-7541 41 PERMIT APPLICATION DATA SHEET 10w*. _ OWNER RAPAdCtC3,00,, Proposed Building Use L -J) 6 A, J/` Building Inspector : P. No. Date 0. At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY �y All items have been submitted . ........................................ Plot plans, 3/4 sets, signed by preparer of plans.................. Complete plans, 3/4 sets, signed by preparer of plan s!t ................ . 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans. ............ . 5• Hazardous Material Form. ............................................ Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... 9. Mobilehome data a d anufactu er's i s allation instructions, 2 sets. ........... esof $ ,l l ................................ . mpact fees as shown on attached schedule. . California Department of Forestry plan approvaGi ,�./. i -J..... ..... 3 Flood elevation letter (100 year flood) by CaliforP�ineer. .. ............ . 14. Sanitation and plot plan approval GNI 4�0 Health Department . ............ 15. City of Chico plumbing permit . ................................ :......... 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Paiking: . ........ 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval required prior to occupancy). .. Preanspection requeis 20. Pre -inspection for required. . to Building Inspector (Date) 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... . Owner -Builder Verification (Given to owner_, Mail to owner _)............ 4. Recorded copy of Agricultural Acknowledgement Statement . .................. __ 25. Letter of signature authorization . .................... . ................... 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ..................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... Plan check list. l ..: ':................ .................... . b � 7~e�Clpre e.rir When you issue the permit, process as follows: Mail to owner. _f�Mail to contractor. Telephone and hold for pickup at office. Deliver with inspector. Other Parcel Creation Acreage Applica Date ��/9�• Copy of Haz-Mat form sent Health Dept. Fire Dept. Copy of plans sent Health Dept. Firp Dept. Other The following data must be submitted prior 1. Index permit for above items No. 2. Additional items required: Air Pollution Date Date new ft7not cWAed above). Z Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Plans checked by Date Plans approved by rS Date Sets of plans on hold in File cabinet AP folder /`....., n-.....i...enf -f P­61:_-­-4Lc -- - 1 E.H. US&04LY �+Plot PLa Amched Floor Plea Anwh Smt to B.D. ILA = TO: Building Department,,,�,�� / FROM: Environmental Health SUBJECT: Sanitation Clearance a ��Ietdi-tiose Lh 7 -3o? - Owner Location AP# Plan Approved for: Sewage Disposal Water Supply: Public Private Well Clearance for-,,�bedroom Thome. Other Hold final for: Final clearance O.K. for: NOTE: a Environmental ealth Specialist Date Q/o1) COUNTY OF BUTTE - OWNER DEPARTMENT OF DEVELOPiKENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 - TELEPHONE 916)538-7541 (916)'538-7541- OWNER PROPOSED BUILDING USE 100 3 &Z 3. SCHOOL DISTRICT FEES C4,1f 4-e-� (paid at District Office).. .. . . .......... SEMW FEES _. (paid at Building Department) Residential....... x 6 6 36 -0 unit amt. Commercial (sqft) x =$ sq.ft. amt. URBAN AREA FEES (paid at Building Department) Residential (per unit) x =$ # units amt. A. P. #_ �7- 320 -d6 DATE /3 %�- REC. # DATE REC Commercial (per sq.ft) x =$ sq.ft. amt. 4. RECREATION DISTRICT FEES (paid at District Office) ......................... 5. DRAINAGE DISTRICT FEES M"-,6-.- (Contact SRA FIRE Land Development Division) .............. INSPECTION AND PLAN CHECK = $89.00 ...... 71D J3' (paid at Building Department) �A>-7 . OTHER tO _ 00 At time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. APPLICANT DATE -j6 COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-754 PERMIT NO. APPLICATION AND PERMIT- �- ASSESSOR PARCEL NUMBER ,� , 31,0' -C)6/ - ZONINGS, BUILDING PERMIT OWNER ' ! ^' /� O ' TELEPHONE ,SO. FT. OCC. BUILDING VALUATION OWNER'S MAJU o 3 CONTRACM&S NAME YovlCiYk 9/6 TJNN y-©�/ ca) D coNrnAcroRs MARJ �So�2� /k,� W /'A� ,t o 5� � tt�.tt I� Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Fling Fee $ " ' 20.00 LENOEI S MAILING ADDRE'S'S Permit Fee eqz—. ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee - /J $ , 5 . 6' Energy Plan .Checking Fee : �'•- a $ ARCN?ECr OR ENGWEEA'S MAILING ADDRESS Penalty $ BUBDINGADORESS (] 3PERMITTEE S PLUMBING PERMIT Fling Fee 20.00 �(�/ . Each Trap 7.00 117, LOT NO. SUBON61ONSNAME PA% Solar Of heat pump water heater 23.00 Water piping 15.00 USEOFSTRUCTURE SF 0/0uplex ❑ Mobilehome ❑ Other SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 /4 - Building sewer 15.00 TYPE OF WORK New .&' Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: �Q2 Mobile Home S1 G1 W1 920.00 PERMITTEE S Contractor ELECTRICAL PERMIT Filina Fee 20.00 Main Service ( eoov oOR LER LEsSSs ) 20(M 23.00 - 3 - Main Service ( 200A TO I000A ) 48.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class LIc. No. • OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, army employees with wages as their sole compensation. will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLAR;;TION 1 hereby affirm under penalty of perjuryone of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work forwhich this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 13 I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavation over 5'0" deep and demolition or construction of structures over 3 t//o��ries in height. NEW�CDONST. A;; ( D 3 WING OCCans 3.Sd 30 FT. . NEW CONST. MULTI.OUTLET NON-RESIO. ( BRANCH CIRCUITS ) 97.50 •I POWER APPARATUS (a SINGLE OUTLET CIA. ) Ex. Occup. (OUTLET OR FORUAES) Q'-50 SAL FIXED APPLNS. OR Ex. Occup. ( (RESIO.) EA) 5.00 .UTLFrs Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE S mvn Contractor 6Y.15 MECHANICAL PERMIT Fling Fee 20.00 Heating �( Cooling Hood 8.50 Ventilation PERMITFEE S , Contractor Mobile Home Installation Fee Is Energy Inspection Fee $ c co T TOTAL FEE $ , I 11AZ. -'- 1 D. FEES I IMP I FL 0 CDf P ND ISSUE This permit is*hereby issued under tris of the Butte County Code and/or indicated above for which fees have BY PERMITEXPIRESON applicable provisions Resolutions to do work been paid. Date (Date) /Ill Receipt No.PCfZ 0.5-10+ V G WHITE -D.D.S. -8.01 CANARY- ASS E OR PINK -INSPECTOR GOLDENROD -APPLICANT I Ge/a-/-&-T� �F'7"V�''►i^�'�"'�Y'�"�'t�R�%�i"'M"�;.r- BUTTS COUNTY PARRS DEVELOPMENT FSS CERTIFICATION FORK CHICO AREA RECREATION AND PARK DISTRICT Assessor Parcel Number(s) — 22-0 —o61 Property Owner /� �/ a, Project Location/Address �/�/Gl.Yt0S� Subdivision Lot Number(s) y Residen al Development: (check one) New Development _Alteration/Addition _Mobilehome(s)_Non-Residential to Residential Total Number,of Dwelling Units Comment: B 9 Department Representative ate. Chico,Area Recreation and Park District(CARD) certifies that Applicant Name) (Street Address) City ate na " ri / Phone Number has complied with -the requirements of Butte Co. Resolution No. 90-140 by payment for dwelling units @ $1,189 for total payment of $ CARD Representative Date PAID BY CHECK NO. BANK N0. PAID BY CASH RECEIPT NO. y[aa REMARKS: Distribution: White --Applicant Pink --CARD park.fee (form revised 11/90) Yellow --Butte Co. Building Dept. Goldenrod --City of Chico Building Dept. �4/C.-V9`1 ':05°i, 0014#8407 CHECK $1189.00 y J; �fy1; l •' - ', ^7"N'!. '*, , +'�'J+'�i!S�I� Rr �' + : �T�'t•'�`°. r � r. . ti,;. „ � a'Vo BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORMt (One Fgrm;,Re.A_'Building) � +� School District .Building Department No. C �— A.P. Number y7' 32. - 061 Jurisdiction ❑ City❑ County Property Owner a - Property Location/Address Subdivison Lot No. l Residential Development ❑ ❑ Sq. Footage No. of Living MHI Addition (Group R) Units Commercial/Industrial ❑ ❑ Sq. Footage New Addition (Including Exterior Roofed Areas) Buiading a artment Representative —Da —te (Floor Plans reviewed by School District Personnel) District Identification No. 9S as r _School District certifies that (Apple ) (Street Address) (City) (Phone Number) � `1, 959Y` (State) , . 'I (Zip Code) has complied with the requirements of Resolution No.'79-- %e" by payment of $ representing School Distri prese square feet. ❑ Check here if fee received represents "Full Mitigation". Paid by Check # Remarks; Bank Number 90- 3 9 %c�,- _ Paid by_Cash Date ease note t at.t a payment described abovFe constitute Mull mitigation of the impacts of this development on school facilities and DOES.NOT,"constitute compliance with District Resolution No. 486-92, nor have the requirerrents.imposed as a mitigation measure by the City of Chico on Pre -zone No. been satisfied. White (applicant), Yellow (building department), Pink (school district) feeform.wk, (a/ea) And when recorded mail to: Building Division 4 95-0135451' Rec Fee 9.00 1 COP 1.50 #7 County Center Drive _ Recorded I Cash 10.50 Oroville, Ca. 95965 Official Records 1 County of 1 Butte 1 Candace J. Grubbs Recorder 1 _ :,,t�;r^�,.:..; • . 12:48pm 25 -Apr -95 1 PURL XX 2 J AGRICULTURAL STATE OF ACKNOWLEDGMENT* . ,,..~ . FOR RESIDENTIAL DEVELOPMENT �'� Section 26-8 of the Butte. County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described..herein is • adjacent.:to land or included within -an area. zoned. for- agriculturai. purposes, and. residents of this property may be subject to inconveniences or discomfort from the use of. agricultural chemicals; including, but not limited to herbicides. pesticides, and fertilizers. and from the pursuit of agricultural operations including, but not limited to cultivation. plowing, spraying, pruning, and harvesting which occasionally generate dust; smoke, noise. and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal. necessary farm operations. All that real property situate in the County of Butte. State of California. described as follows: /�� 'Ocl' -10 SEE ATTACHED LEGAL DESCRIPTION Date: 4/25/95 PROPERTY OWNERS: LAIIDELINA CRESP State of California ) County of BUTTE ) On 4/25/95. before me, TAMI BARLOW personally appeared LAIIDELINA CRESPO personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted. executed the instrument. WITNESS my hand and official seal. oFF78221 �L t"n 9�err TAMI BARLOW Cl NOTARY PUBLIC - CALIFORNIA Q COUNTY OF BUTTE (NO Sil;natur • My Commission Expires November 19, 1990 AMI BARLOW A.P.# J412— 3 a- U- 0 61/ DESCRIPTION ALL THAT CERTAIN REAL PROPERTY, SITUATE TN THE STATE OF CALIFORNIA., COUNTY OF BUTTE,. DESCRIBED AS' FOLLOWS: PARCEL" I PARCEL 4, AS SHOWN ON THAT CERTAIN PARCEL MAP, RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE., STATE OF CALIFORNIA, ON OCTOBER 8, 1992, IN BOOK 128 OF MAPS, AT PAGE(S) 4-7 AND 48.. PARCEL II: AN EASEMENT FOR ROAD AND PUBLIC UTILITIES LYING WITHIN HEIDEROSE LANE, AS SHOWN ON THAT CERTAIN PARCEL MAP, RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON OCTOBER 8, 1992, IN BOOK 128 OF MAPS, AT PAGE(S) 47 AND 48. EXCEPTING THEREFROM ALL THAT PORTION LYING WITHIN THE BOUNDS OF PARCEL I, DESCRIBED HEREIN. J RESIDENTIAL PLAN CHECKING GUIDE 8/91 (S.F., DUPLEX & MISC. ONLY) Bldg. Permit # � O � 7/ OWNER_ Ci,O� A.P. # y� GENERAL Plan Checker S -/ +. Zoning requirements: (sideyards and number of permitted living units). Valuation. lans signed by designer. Proper description of work on application. Existing violations on property. Items on data sheet. N.C., fees, Health, Developer Fees, License law, etc). Recorded notice of violation. PLOT PLAN �4Complete parcel size and -dimensions. -�-_Setbacks, sideyards, easements, etc. Other buildings or structures. Grading, fills, drainage. Flood hazard. Special conditions on creation map, • ustible, and foundations). FAU & FAS road setback. (noise, CDF, fire sprinklers, non -comb - Building or utilities across -lot lines'(Record form). FLOOR PLAN Complete to scale plan with dimensions. VtLocations equired windows for light and ventilation (Sec. 1205). equired windows for second exit (Sec. 1204). kylights (Chapter 34 & Sec. 5207). uman impact glass (Sec. 5406). i equired room sizes, ceiling heights (Sec. 1207). FCIs in baths, garage, kitchen, and exterior outlets (Article 210-8). ight fixtures, switches, receptacles, and exterior receptacles for main- enance of mechanical equipment. of water heater, heating and cooling equipment, other electrical or gas equipment. rage firewall, door size, and closer (Sec. 503(d)(3)). fIilumb,ng - 3'0" exterior exit door (sec. 3304 (f). ireplace and wood stovelocation, alcoves, and clearance. moke,detectorsti(Sec."1210).i fixtures, water closet clearances and shower size. STRUCTURAL DETAILS Standard bracing or engineered design (Table 25V.) Unusual shape, size, or split level -house requiring •lateral design.` Clerestory requiring balloon framing and/or engineering. ' Three story building requiring engineered calculations aad,plans.• `•' . Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. • Elevations and wall construction details complete enough to construct building Roof construction details complete enough to construct building. Fireplace construction details and calcs if necessary. —Rafter ties or bearing ridge beam. } Garage door or porch header sizes. Stud heights. . Adobe soils - special foundation design. . Retaining walls requiring design. . Special Inspection required. 8/91 RESIDENTIAL PLAN CHECKING GUIDE MISCELLANEOUS ITEMS TO LOOK OUT FOR ti " Stairway details: landings, rise and run, head clearance, handrails • (Sec. 3306). Guardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). Exterior plaster - weep screeds (Sec. 4706). Proper roof pitch for roof convering (Chapter 32). Roof covering type - (fire hazard). - Foam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts, etc. ..'O—.Two exits on three-story dwellings (sec. 3303 & see Mezannines - 1716). ttic access and ventilation (Sec. 3205). . Underfloor access and ventilation (Sec. 2516). Combustion air for fuel burning appliances - L.P.G. requirements. oise requirements on duplexes. . Energy design. lashing at all exterior openings. CDF responsa area requirements. y 2, .� 4- y '> � arm CERTIFICATE OF COMPLIANCE-. RESIDENTI7IL Page 1 CF- IR Project Tit.le.......... Crespo Residence. Dat.e........ 03/14/95 Project Address........ Heiderose Lane Chico 95 �� f�1 Documentation Author... Patricia Chaix 1 Building Permit # Company ................ Narrow Gauge Consulting Telephone ............... (916) 274--2033 1 Plan Check / Date Compliance Met.hod...... HICROPN94 by Enercomp, Inc. 1 Field Check/ Date 1 Cl irnat-9 Zone........... 11 ..... _............ ......... ......................................... ...... _....... _. 1 MICROPAS4 v4.02 File. -C7795 Wth CTZlIS92 Program, FORM CF -.1R 1 1 User# -MP 1035 User --Narrow Gauge Consulting Run --Larson 7795 1 GENERAL INFORMATION Conditioned'F1oor Berea..... Building Type...........,...... Construction Type ......... Building Front. Orientation. Number of Dwelling Units... Number of Stories............ Floor Constructiort Type... . 2_648 sf Single Family Detached New ' Front. Facing 30 deg (NE) Raised Floor (Package E) BUILDING SHELL INSULATION Component. Insulation Assembly Type R.--va Iue U -Value Locat i on/Corrinents Wall R--19 0.065 front wall, left wall, back wall right. wall, garage wall, attic wall Door R 0 x.330 front door, back door, garage door Floor R7_19 0.037 to crawl space Roof R--30 0.031 to attic F F. NF. STRAT I ON # of I nt.er i or Over-_. Area U- Pan-•- Shadi.rig/ Exterior hang/ Framing Orientation (s f) Value es Description Shading Fins Type Window Front. (NE) 30.0 0.850 2 Default Norte Yee; Metal Window Front (NE) 49.0 0.850 2 Default None None Metal W i rtdow Le f t (SE) 88.0 0.850 2 Default Norte Yes Metal Window Pack. (SW) 58.0 0.850 2 De fau It Mone YesOtaI Door Back (SW) 93.0 0.850` 2 Default. None: Yes Metal Door Back (SW) 40.0 0.850 2 Default None Noee OMMtrINk l Window Back (SW) 14.0 0.850 2 Default None,RhW i rtciow R. i. ght. (NW) 4 t . 0 0.850 - 2 De f au 1 t Nonr; e � THERMAL MUSS _... ._......... _ � Area Thickness Type Exposed (s f) ( in) Lci��olnts _..._....... _.......... ----------- _.......... _-....... _.......... _. __.._..._............ ........ ......_.__.._!_..._...._...._._..__..._._........... _.._._..--... Inter iorl•iorz Yes 17 4.0 i It Na hearth Int.eriorVert. Yes 48 4.0 rt.v heart.h Inter i or-Fiorz Yes 120 1.0 co ter t. i. 1 e InteriorVert. Yes 260 1.0 vertical tile CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF --1R Project Title., ........ Crespo Residence Date........ 03/14/95 MICROPAS4 v4.02 File --C7795. Wth--CTZ1 1592 Program -FORM CF -'-1R User# -MP 1035 User --Narrow Gauge Consulting .Run --Larson 7795 HVAC SYSTEMS Minimum Duct Duct Thermostat. Equipment Type Efficiency Location R --value Type Furnace 0.780 AFUE CraBilspace R"4.2 Setback. ACSplit 10.00 SEER Crawl pace R--4.2 Setback WATER. HEATING SYSTEMS ...... _.........-._................. _..._._.._.._...._._..._._......._. Number Tank External in .Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) Ovalue Storage Gas Standard 1 0.60 EF 50 R-12. SPECIAL. FEATURES/REMARKS E Note: Habitable square footage for energy. compliances may vary from measurement for other purposes. Ceiling Ins: Minimum R30 Wall Insulst ion: , Miri mum R.19 'Floor Insulation: Minimum R19 Water Heater.: 50 ,gal . max. / Gas / CEC approved . . . . . . . . . MINIMUM ENERGY FACTOR. = 0.60 . . . . . . . . . R12 external wrap required -- NOTE: . . . . . . . . . . Be sure wrap is installed in accordance . . . . . . , . . . with Prop. §5 Toxic Warnings; label . . . . . . . . . requirements Thermal Mass: 385 of minimum thermal,mass required per plan Glazing: 413 of max. '/ Metal frames, / Maximum U -values: . . . . . . . . 0.85 (NFRC labels required) Heat.ing:. Minimum' AFUE 78 Cooling: Minimum SEER 10 Ducts: Minimum R4.2 in craw Ispace .. + . I, t �.. .'',, �. ..' r r f � 1 ., �. [' � 1 <' i..: •• �. •.•.r . �, , ., ,. ...r E" r .. : + .. .. r ,. . � r .. .. , • • • ... ,5 ... t � ,� 1 1 ' :t". 1 : �. .. .i � is l �. 1 .. r'. r r +�. r 1 � CERTIFICATE OF COMPLIANCE: RESIDENTIQ Page 3 CF --1R Project Title ...... _. Crespo Residence Date......... 03/14/95 MICROPAS4 v4.02. File -•-C7795 Wth-CTZl1S92 Program -FORM CF71R i User&-MP1035 User -Narrow Gauge Consulting Run -Larson 7795 COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -241 Parts I and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted,for a single building plan to be built in multiple orientations, any shading feature that is varied,is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... Company. Address. Phone.,. License! S i geed . . -------------- (date) ENFORCEMENT AGENCY Name...., Title ... ..... Agency.. ------------------------- Phone ... Signed.. 4 (date) DOCUMENTATION AUTHOR Name....: , Pat.ricia Chaix Company. Narrow Gauge Consulting Address. P. 0. Box 1742 . Nevada City, CA 95959 Phone.. , (916) 274-2033 ' Signed.. (date) C. a r t i f 1 Unergy cap iy '4 Patricia Chaix R 92-92-181 r r r r C -A-0 E ' C California socia on of Building Energy Cormkonts._ s POINT SYSTEM Page I P -2R Project Title.......... Crespo Residence Date........ 03/14/95 Project Address........ Heiderose Lane Chico Documentation Author....Patricia Chaix Company ................ Narrow Gauge Consulting - Telephone .............. (916) 274-2033 Flan-Che-ck /-Date ----- — --------- Compliance Method...... MICROPAS4 by Enercomp, Inc. Field Check/ Date Climate Zone ........... 11 MICROPAS4 v4.02 File -C7795 Wth-CTZ11592 Program -FORM P --2R Userif-MP 1035 User -Narrow Gauge Consulting Run -Larson 7795 MICROPAS4 POINT SYSTEM SUMMARY Energy Use Points ----------------------- --------- Space Heating .......... -6 Space Cooling...... : ... 3 Water Heating.......... 4 Total I Building complies with Point System GENERAL INFORMATION Conditioned Floor Area..... Building Type. ............. Construction Type ......... Building Front Orientation. Number of Dwelling Units ... Number of Building Stories. Floor Construction Type.... Number.of Building Zones ... Conditioned Volume......... Footprint Area.... _ ...... Slab -On -Grade Area......... Glazing Percentage.......... ZAverage Ceiling Height..... 2648 sf Single Family Detached New Front Facing 30 deg (NE) Raised Floor (Package E) 22550 cf 2648, sf 0 sf 15.6% of FA 8.5 ft GLAZING Orientation Glass Area % Glass p. North 79.0 2.98% b. East 88.0 3.32% c. South 205.0 1.74% d. West 41"0 1,55% e. Skylight 6.0 0.00% Total 413.0 15.60% POINT SYSTEM Page 2 P --2R Projpct Title.......... Crespo Residence Date........ 03/14/95 MICROPAS4 v4.02 File --C7795 Wth--CTZ11592 Program -FORK P ---2R User# MP 101:35 User -Narrow Gauge'Consult-ing Run-L,arson 7795 SCORE CARD Point Total: w 2 1 57 4 Measure Points 1. Ceiling Insulation (U Value) 0.031 2. Wall Insulation (U --Value) 0.065 0 3. Raised FloorInsulation (U --Value) 0.037 0 4. Slab Edge Insulation (F2 Fact -or) 0.000 0 5. Infiltration .-- Ducts in Unconditioned Space Yes 0 6. Fenestration Heat Loss (1) --- Value) 0.850 at 15.60% -5 Sum 1--6 7. Fenestration Heat Gain SC Effective Shade % Fe -nes- Shade- % Fenes- Effective- tration open trat i on ness Ratio North 2.98% x 0.766 = 2.29% 0.866 0. East 3.32% x 0.665 = 2.21% 0.746 0 South 7.74% x 0.445 3.44% 0.794 0 West 1.55% x 0.659 1.02% 0.747 1 Skylight, 0.00% x 0.000 0.00% 0.000 0 8. Interior Therma I Mass (Mass/Area) 0.309 1 9. Exterior Wa 11. Mass (Mass/Area) 0.000 0 Sum 7-9 E qu i pment Duct Effective Zonal Efficiency Efficiency Efficiency Control 10. Heating 0.780 AruE x. o.. no 0.647.AFUE No 11. Cooling 10.000 SEER. x 0.860 8.600'SEER No 12. Water Heating Tank External Energy Size Insulation Tank Type Heater Type Factor (gal) R value Distribution Type 1. Storage Gas 0.60 50 R-12 Standard' 2. n/a n/a n/a n/a R---n/a n/a Point Total: w 2 1 57 4 r f . 4 ^ 1` _�.. . 1 S� '� 1 tt � T .� 1. + pct, f. ' +: C: ,. POINT SYSTEM Paye 3 P• -2R Protect Title.......... Crespo Residence Date ........ 03/14/95 1 MICROPAS4 v4.02 File --C7795 Wth-CTZ1 1592 Program -FORM P -2R 1 User #--MP 1035 User -Narrow Gauge Consulting Run --Larson 7795 1 BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond-- Thermostat Height Vent Area Zone Type (sf) (cf) Units it.ioned Type (fit) (sf) }HOUSE Residence 2648 22550 1.00 Yes Setback -2.0 n/a SC SC OPAQUE SURFACES Area Pan_-• Frame Open Area U•- --------------- Insul Act Shading/ Solar Form 3 Location/ Sur f ace (sf) value 0ya 1 AS Tilt Gains Reference Comments HOUSE _.._..__..._..._._..._.__ _.___...._._...... _._. _._._ --------- 1 Wall 283 0.065 R-•19 30 90 Yes; None front. wall 2 Wall 423 0.065 R-19- 120 90 Yes None left wall 3 Wall 378 0.065 R-19 210 90 Yes None back wall 4 Wall 466 0.065 R--19 300 90 Yes, None right wait 5 Wall' 148 0.065 R••-19 30 90 No None garage wall 6 Wall 54. 0.065 R-19 30 90 Yes None attic wall 7 Door 40 0.330 1-0 30 90 Yes; None front door 8 Door 20 0.330 R-0 210 90 Yes None back door 9 Door 36 0.330 R-•0 30 90 No None garage door 10 Floor 2648 0.037 R--19 0 0 No None to crawlspace 11 Roof 2671 0.031 R-•30 0 O Yes None to attic FENESTRATION SURFACES it of Vent SC SC Interior Area Pan_-• Frame Open U-- Act. Glass Int Shading/ Surface ----------- (sf)_ es Type Type' value Azm Tit Only Shade Description HOUSE ----- ---- _.._..__..._..._._..._.__ _.___...._._...... _._. _._._ 1 Window 30.0' 2 Metal Slider 0.850 30 90 008 88 0.78 Default 2 Window 29.0 2 Metal Slider 0.850 30 90 0.88 0.78 Default 3 Window 20.0 2 Metal Slider 0.850 30 90 0.88 0.78 Default 4 Window 8.0 2 Metal Slider- 0.850 120 90 0.88 0.78 Default 5 Window 8.0 2 Metal Slider 0.850 120 90 0.88 0.78 Default. 6 Window 16.0 2 Metal Slider 0:850 120 90 0.88 0.78 Default 7•Window 16.0 2 Metal Slider 0.850 120. 90 0..88 0.78 Default 8 Window 40.0 2 Metal Slider 0.850 120 90 0.88 0.78 Default 9 Window 12.0 2 Metal- Slider.0.850 210 90 0:88 0.78 De.f6ult. 10 Door 40.0 2 Metal Slider 0.850 210 90 0.88 0.78 Default 11 Window 6.0 2 Metal Slider 0.850 210 90 0..88 0..78 Default. 12 Window 24.0 2 Metal Slider 0.850 210 90 0.88 0.78 Default 13 Door 53.0 2 Metal Slider 0.850 210 90 0.88 0.78 Default. 14 Window 16.0 2 Metal Slider 0.850 210 90 0.88 0:78 Default 15 Door 40.0 2 Metal Slider 0.850 210 90 0.88 0.78 Default. 16 Window 14.0 2 Metal Slider 0.850 210 90 0.88 0.78 Default 17 Window 18.0 2 Metal Slider 0.850 300 90 0.88 0.78 Default. 18 Window 6.0 2 Metal Slider.0.850 300 90 0:88.0.78 Default 19 Window 17.0 2 Metal Slider 0.850 300 90 0..88 0.78 Default .. � ' �'.9: .. t 'x � .. . c� - �. . � r" .. ,� � ,� . 1. � .' , rp >r • ; ' x r .. � _ cr � ,1 c � .. � } 1 �c � � i; ... _ � ,. r r ,, .. 1.;i . 1+ �. - . - 1 t t .. .. �� .. � .. � 1 . POINT SYSTEM Page 4 P -2R Project Tit.le.......... Crespo Residence Date........ 03/14/95 MICR.OPA,S4 v4.02. File --C7795 Wth••-CTZ1 1592 Program -FORK P --2.R User #--•MP 1035 User -Narrow Gauge Consulting Run -Larson 7795 OVERHANGS AND SIDE FINS HOUSE. ,1 InteriorHorz 17 4.0 21.0 0.59 R-0.0 --- Window .....- ------ Overhang ----- --- Left Fin ------- vertical Right Fin- -- -in- -- 120 1.0 24.0 • 0.67 R.-•0.0 Area Area tile 4 InteriorVert 200 1.0 24.0 0.67 R--0.0 Left Rght HVAC SYSTEMS Surface (sf) Hght- Wdt.h Dpt.h Hght Ext Ext Ext Dpth Hght- Ext. Dpt.h Hght- IiOiJSF. 0.780 AFUE Crawlspace R--4.2 0.830 ACSplit 10.00,SEER Crawlspace R--4.2 0.860 WATER HEATING SYSTEMS 1 Window 30..0 5 n/a 6 0 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window . 8.0 4 n/a 2 0.5 n/a n/a, n/a n/a n/a n/a n/a n/a 5 Window 8.0 4 n/a 2- 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 16.0 4 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 16.0 4 n/a 18 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 40.0 6.5 n/a 2. 1 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 12.0 4 n/a 12 0.5 n/a n/a n/a n/a- n/a n/a n/a n/a 10 Dook 40.0 6 n/a 12. 1 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 6.0 3 n/a 12 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 24.0 6 n/a 17 0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 53.0 6.5 n/a 17 0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 16.0 4 n/a 2 0:5 n/a n/a n/a n/a n/a n/a n/a n/a 17 Window 18.0 3.5 n/a 2. 0.5 n/a n/a n/a n/a, n/a n/a n/a n/a 18 Window 6.,0 1.5 n/a -2 0.5 n/a n/a n/a -n/a n/a n/a n/a n/a 19 Window 17.0 3.5 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS . Area. Thick. Heat Conduct-- Surface Mass Type GO Ain) Cap i v i ty R --value Loca t i on/Corrvnent.s HOUSE. ,1 InteriorHorz 17 4.0 21.0 0.59 R-0.0 horizontal hearth 2 Interio-rVert 48 4.0 21.0 0.59 R--0.0 vertical hearth 3 Inter i orHorz 120 1.0 24.0 • 0.67 R.-•0.0 counter tile 4 InteriorVert 200 1.0 24.0 0.67 R--0.0 vertical the HVAC SYSTEMS Minirnurn Duct. Ducat. Duct. System Type Efficiency Location R --value Efficiency HOUSE Furnace 0.780 AFUE Crawlspace R--4.2 0.830 ACSplit 10.00,SEER Crawlspace R--4.2 0.860 WATER HEATING SYSTEMS Number Tank. Externa I in Energy Size Insulation Tank Type Heater Type Ditstribution Type System- Factor (gal) R --value 1 Storage Gas Standard 1 0.60 50 R-12 r ?J J r? 3 14 POINT SYSTEM Page 5 P72R Project Title ....... Crespo Residence D6te ........ 03/14/95 MICROPAS4 v4102 Fle-C7795 Wth-CTZ11S92 Program -FORM P --2R Userit-MP1035 User -Narrow Gauge Consulting Win -Larson 7795 i SPECIAL FEATURES/REMARXKS Note: Habitable square footage for energy compliances may vary from measurement for other purposes., Ceiling Ins: Minimum'R30 Wait Insulation: Minimum R19 Floor Insulation: Minimum R19 Water Heater: 50 gal. max. / Gas / CEC approved . ... . . . . . . MINIMUM ENERGY FACTOR = 0.60 . . . . . R12 external wrap required - NOTE: . . . . ... . . . . Be sure wrap is installed in accordance . . . . . . . . . . with Prop. 65 Toxic Warnings label ... . . . . . . . . . requ i rerfients Thermal Mass: 385 of minimum thermal mass Aquired per plan Glaxing: 413 of max. / Metal frames Maximum U --values: . . . . . . . . . 1 0.85 (NFRC,Iabels required) Heating: Minimum AFUE 78 Cooling: Minimum SEER 10 Duct-;: Minimum R4.2 in crawl space x HVAC SIZING Page 1 HVAC Project Title........... Crespo Residence Dat.e........ 03/14/95 Project Address........ Heiderose Lane -------•--.--___._._ ------ _ Chico Documentation Author... Patricia Chaix E31xi lding Perrnit if Company................. Narrow Gauge Consulting Telephone .............. (916) 274--2033 P16n Check'/ Date _________________ .Compliance Method...... MICROPAS4 by Enercornp, Inc. 1 Field Check./ Date 1 Climate 20ne ......... 1. 11 . ......... MICROPAS4 v4.02 File -C7795 WQ-CTZ1 1592 'PrograrrHVAC SIZING User#& -•MP 1035 User -Narrow Gauge Consulting Faun --Larson 7795 GENERAL INFORMATION Fboor Area ................. 2648 sf Volume....................... 22550 cf Front Orientation.......... Front Facing 30 deg (NE) Siring Location ............ CHICO EXP STA - Lat.itude................... 39.7 degrees Winter Outside Design...... 27 F Winter Inside Des,ign....... 70 F Summer Outside Design ...... 102 F Sumner Inside Design....... 78 F Summer Range ............... 37 F Interior Shading Used....... No Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fract.ion....... 0.20.. Description HEATING AND COOLING LOAD SUMMARY Heating Cooling (Ftuh) (Btuh) Opaque Conduction and Solar...... 14032 6665 Glaring Conduction ............... 15095 8425 Glazing Solar .................... n/a 11625 Infiltration ............:....... 14260 4686 Internal Gain .................... n/a 2550 Ducts ............................. 4339 1698 Sensible Load............ ...... 47726 35649 Latent Lorad.... .... ...... ....... n/a 7130 Minimum.Tota1 Load 47726 42779 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment.. Other relevant design factors such as air -flow requirements, outdoor design temperatures, coil sizing, availability of equipment., oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Mandatory Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION I DESIGNER 1 ENFORCEMENT I Building Envelope Measures • §150(a): Minimum R-19 ceiling insulation. X §150(b): Loose fill insulation manufacturer's labeled R -Value. X • §150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). ' §150(d): Minimum 8.13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. X §150(l): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no N/A greater than 2.0 perm/inch. §118: Insulation specified or installed meets California Energy Commission quality standards. Indicate type and form. X §116.17: Fenestration Products, Exterior Doors and Infiltration/Exfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b.' Manufacturad fenestration products have label with certified U -value, and infiltration certification. X c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §I 50(f): Special infiltration barrier installed to comply with §151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control X 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission— X §150(i): Setback thermostat on all applicable heating systems. §1500): Pipe and Tank Insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined intedorlexterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). X 3. All buried or exposed piping insulated in recirculating secticns of hot water system. 4. Cooling system piping below 55°F insulated. 5. Piping insulated between heating source and indirect hot water tank. ' §150(m): Ducts and Farts 1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exha;:31: fan systems have backdraft or automatic dampers X 3. Gravity vent?atng systems serving conditioned space have either automatic or readily accessible,. manually operated dampers.. §114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light X 2. System is installed with: a. At least 36' pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa X 3. Pool system has directional inlets and a circulation pump time switch. §115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously buring pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/ftr.) X Lighting Measures §150(k): 40 Iumenswatt or greater for general lighting in kitchens and moms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. X Revised January 1992 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -IR Project Title.,..,_..... Crespo Residence Date,.,.,.,. 03/14/95 Project Address ... : .... Heiderose Lane _--___.__-_____.__________ Chico Documentation Ahthor ... Patricia Chaix 1 Building Permit ff. Company: ....... ! ....... Narrow Gauge Consulting i Telephone..; ........... (916) 274-2033 .1 Tan Check /Date Compliance Method:..... MICROPA54 by Enercomp, Inc. i Field Check/ Date Climate Zone.... , , ...... 11 . ...... i MICROPAS4 v4.02 File -C7795 Wth-CTZ11S92 Program -FORM CF -1R UserD"MP1035 User-Krrow Gauge Consulting Run -Larson 7795 GENERAL INFORMATION Conditioned Floor Area..... Building Type. ............. Construction Type ........ Building Front. Orientation. Number of Dwelling Units... Number of Stories Floor Construction Type.... 2648 sf Single Amily Detached New Front Facing 30 deg (NE) Wised Floor (Package E) BUILDING SHELL INSULATION Component Insulation Assembly Type R --value U -Value Location/Comments .. ..................... . . . ...................... Wall ........ R.---19 . ..................... . ..... . ....... . ..... . ............................... 0.065 front wall, I ........... ­ ...... . ...... left wall, back . ...... . ...... . . wall . . ........ right wall, garage wall, attic wall Door R. --O 0.330 front door, back door, garage door Floor R-19 0.037 to crawlspace Roof R-30 0.031 to attic FENESTRATION # of Interior Over.-.. Area U- Pan- Shading/ Exterior hang/ F-raming Orientation (sf) Value es Description Shading Fins Type Window Front (NE) 30.0 0.850 2 Default None Yes Metal Window Front (NE) 49.0 0.850 2 Default None None Metal Window Left (SE) 88.0 0.850 2 'Default None Yes Metal Window Back (SW) 58.0 0.850 2 Default None Yes Metal Door Back (SW) 93.0 0.850 2 Default None Yes Metal Door Back (SW) 40.0 0.850 2 Default None None Metal Window Back (SW) 14.0 0.850 2 Default None None Metal Window Right (NW) 41.0 0.850 2 Default None Yes Metal THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments ........... IntiriorHorz Yes . ........ ....... ....... .......... .. . ....... .............. 17 4.0 . . . . . ..................... ------------- horizontal hearth InteriorVert Yes 48 4.0 vertical hearth InteriorHorz 'Yes 120 1.0 cointer tile InteriorVert Yes 200 1.0 vertical tile r CERTIFICATE OF COMPLIANCE: RESIDENTIAL., Page 2 CF ---IR Project Title......... Crespo Residence Date........ 03/14/95 i MICROPAS4 v4.02 File -C7795 Wth;-CT71 1S9r Program- --FORM CF --1R I User* -MP 1035- User.. -Narrow Gauge Consulting Rua -Larson 7795 i Equipment Type Furnace ACSpIit I WAC SY STF. MS Minimum Duct Efficiency Location 0.780 AFUE Crywlsspace 10.00 SEER. Craw 1 space WATER HEATING SYSTEMS Duct. Thermostat R --value Type 04.2 Setback. R•--4.2 Setback Number Tank. External in Energy Size Insulation Tank. Type Heater Type D i st.r ibut i on Type System Factor (gal) R -value Storage Gas Standard 1 0.60 EF 50 R-12 SPECIAL FEATURES/REMARKS Note: Hab i tab l e square foot., -age f or energy comp l i:.ances may I vary from measurement 'for other. purposes. Ceiling Ins! Minimum R30 Wall Insulation: Minimum R19 Floor Insulation. Minimum R19 Water Heater: 50 gal. max. / Gas / CEC approved . . . . . . . . . MINIMUM ENERGY FACTORS .. 0.60 . . . . . . . . R12 external wrap required -- NOTE: . . . . . . . Be sure wrap is installed in accordance . . .. . . . . . . . with Prop. 65 Toxic Warnings; label requirements Thermal Masi: 385 oaf minimum thermal mass required per plan Glazing: 413 sf max.. / Metal frimes / Maximum U --•values: . . . . . . . 0.85 (NFRC labels required) Heating: Minimum AFUE 78 Cooling: Minimum SEER 10 Ducts: Minimum R4.2 in craw Ispace CERTIFICATE OF COMPI.,IANCE: RESIDENTIAL, Page'3 CF --1R ------------ Project Tit.le.......... Crespo Residence Date. ..... 03/14/95 f MIC,ROPA.34 v4.012 File. -.C7795 Wth CTZ 1 i S92 Program --FORM CF -..IR 1 Userit---MP 1035 User. --Narrow Gauge Consulting -Run Larson 7795 COMPI.JANCE STATEMENT This; certificate of cornpl.iance lists the building features and performance spec i f i cat i ons • needed to comply with T i t. l e--24, Par=t.s 1 and 6. of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been !:jigned by the individual with overall design -responsibility.. When this certificate of compliance is subrnit.t.ed for .'a single b-iailding plan to be'buiIt. in multiple orient.at.ions, any shading feature that is, varied is indicated.in the Special Features/ Remarks section. DESIGNER or OWNER -DOCUMENTATION AUTHOR Name.... Company. Address. Phone... Li cense.. Signed... Name.... Title... Agency.. Phone... Signed.. (date) ENFORCEMENT AGENCY --------------- (date) Name. ... Patricia Cha ix Company. Narrow Gauge Consulting Address. P. 0. Box 1742 Nevada City, CA 95959 Phone... (916) 274--2033 Signed.. Certified Energy Aaalys,t Patricia Chaix R 92-92-181 ' rr rr �CABEC California Association of Building Energy Consultants POINT SYSTEM\�, Page 1 P -2R Project Title .......... Crespo Residence Date........ 03/14/95 Project Address ........ Heiderose Lane ----------------- Ch i co Documentation Author ... Patricia Chaix 1 BU_50 ing Permit 4 Company ................ Narrow Gauge Consulting : Telephone..............._ (916) 274-2033 1 Plan Check-/ Date ee Compliance Method...... MICROPAS4 by Enercomp, Inc. 1 Field_00-c750 -a Climate Zone............ 11 MICROPAS4 v4.02 File -C7795 Wth-CTZ11S92 Program -FORM P --2R User0MP1035 User -Narrow Gauge Consulting Run-Larsod 7795 ................ . ............ . .......... . ...... . ...... . ......... ................. . .. . ...... . ............. I . . ...... . ........... ... ..... ..... . ......... . .. ........... .................. MICROPAS4 POINT SYSTEM SUMMARY . ....... ....... Energy Use Points ---------------------- ------------- Space Heating .......... -6 Space Cooling..._...... 3 Water Heating .......... 4 ---------- Total 1 Building complies with Point System GENERAL INFORMATION Conditioned Floor Area ..... Building Type .............. Construction Type ... : ..... Building Front Orientation. Number of Dwelling Units... Number of Building Stories, Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area ............ Stab--On.--Grade Area ......... Gla2ing Percentage ......... Average Ceiling Height..... 2648 sf Single Family Detached New Front Facing 30 deg (NE) 1. Raised Floor (Package E) 22550 c 2648 sf 0 sf 15.6 % of FA 8.5 ft GLAZING Orientation Glass Area % Glass a. North b. East c. South d. West e. Skylight Tota I 79.0 2.98% 88.0 3.32% 205.0 7.74% 41.0 1.55% 0.0 0.00% 413.0 15.60% . ^ ' _ POINT SYSTEM . � Page`2 ' 9-2R ^ =============================================================================== Project Tit\a'.....''.. Creepm Residence Date...'''.' 03/14/95 | MIC8DPAS4 v4.02 File -C7795 Wtb-CTQ11G92 Program -FORM P -2R | � Ueer#-NP1035 User -Narrow Gauge Consulting Run -Larson 7195 | ' Point Total -G 2 4 1 ===== Measure Points 1' Ceiling Insulation (U -Value) 0'031 �.� -1 ^ 2' Wail Insulation (U -Value)' 0'065 U ' 3' Raised Floor Insulation (U -Value) ^ 0'037 U 4' Slab Edge Insulation (F2 Factor) 0.000 O 5' Infiltration - Ducts in -Unconditioned Space Yes O G' Tmoastratiou Heat Loss (U -Value) 0.850 at 15'60% -5 Som 1-6 7' Famostrotimu.8eat Gain SC Effective Shade % Fenes- Shade % Fmnes- Cffective- tratiun Open tratioo oess Ratio ____ ____ Nurt6 2'98% x 0'766 = 2'29% 0'868 O East 3.32% x 0.665 = 2'21% 8'746 O South 7'74% x 0'445 = 3'44% 0'794 O West 1'55% x 0'658 = 1,02% 0'747 1. Skylight 0'80% x. U'OOO = 0.00%, 0.000 O ' 8' Interior Thermal @deo (Mass/Area) 0,308 1 9' Exterior Wall Mase (Mase/Area) 0.008 O Sum 7-9 Cguipmeot ` Duct Effective Zonal Efficiency Efficiency Efficiency Control 10' Heating 0'780 AFDC x 0'830. = 0'647 AFDC No 11. Cooling 10.000 SEER x 0'860 = 8.608 SEER .o 12' Water Heating - Tank CztwrnaI . . Energy Size Insulation ?oob Type Beater Type Factor (gal) R -value Distribution Type ^ 1' Storage Gas 8'60 50 R-12 Standard ' Point Total -G 2 4 1 ===== _ t., .: • i>' i F � � i �� ' - '.J�)w .. i r � _ � ;., ' r' t 'S , 1 [ , �1 - 1r 1 .( 1 � . l�.t v.. _ ' .. _ i, ' L � � .. � _ n �_ ^fir.' '1�• � �': .. r �`. ,. , � { r � .. _ . .. . G .. � ` Ufa'. .. '1 � .... .. 1 .' r ' .' ' `.. - 'T ` � L POINT SYSTEM Page 3 P -3R =============================================================================== | NICBDPAB4 v4'02 File -C7795 Wth.-CTZ11892 9rogram-FORM P --2R | User#-MP1035 User -Narrow Gauge Consulting Run -Larson 7795 i BUILDING ZONE INFORMATION Fl*mr # of ' Area Volume Dwell Coud- Thermostat Zone Type (sf) (cf) Units itionad Type BOD8C . Residence' 2648 22550 1'00 Yes Setback OPAQUE SURFACES Area O- Iosni Act Soimr Form 3 Sul -face ` (sf) value R-val Azm Tilt Gains Reference HOUSE 1 Wal\ 2 Wmii 3 Wa\i 4 Wa[i 5 Wai1 G Watt 7 Door 8 Door 9 Door 10 Fioor 11 Roof Surface HOUSE 1 Window 2 Wiodow 3 giudmv 4'W i ndow 5 Wiodnw O W iudow ? gindow. 8 Wiodo* 9 Winduw 10 Door 11 Wiodow 12 Window 13 Door 14 Window 15 Door 16 Window 17 Wiudon 18 gindow 19Wirudow 283 423 378 466 148 54 40 20 36 2648 2671 0'065 R-19 30 90 Yeo None 0.085 R-19 120 90 Yes None 0.065 R-19 210 3Q Yes 0one 0'065 R-19 300 30 Yes � None: 8'065 R-19 30 90 No None 0.065 8_19 30 90 Yes None 0'330 R -O 30 SO Yes None 0'330 R -O 210 98 Yes None 0'330 k -O 30 90 No None 0,037 R-19 0 O No 0ooa O'031 R-30 O U Yes Kue 0'78 FENESTRATION Slider ' SURFACES 120 # of Aria Pan- Frame (mf) es Type 30'0 2 Nmtai 29'0 2 Metal 20'0 2 Metal 8.0 2 Metal 8'0 2 Metal 16.0 2 Metal 16'0 2 Metal 40'0 2 Natal 12'0 2 Metal 40'0 2 Metal G'O 2 Matal 24'0 2 Metal 53'0 2 Metal 16.0 2 Metal 40'0 2 Meta\ 14.0 2 Metal 18'0 2 Metal 6.0 2 Metai 17'0 2 Metal Vent Special Height Vent Area (ft) (sf) 2'O o/a Location/ Comments front we\> left wail back wall right wall ' garage wall attic wail front door 6aob door garage door to cra*iepace to attic Vent Sc 8C Interior Open O- Act Glass Int Shading/ Type ______ value _____ Aom ___ Tit ___ Only ..... ....... _ Shade Description ____ ______________ Slider 0'850 30 90 0'88 0'78 Default Slider 0.850 30 SO 8'88 0.78 Default Slider 0'850 30 80 0.88 0.78 Default Slider 0'850 120 90 0'88 0.78 Default Slider 0'850 120 90 8'88 008 Default Slider 0.850 120 SO 0'88 0.78 Default Slider 8'858 120 90 0'88 0'78 Default. Slider 0.850 120 9O 0'88 8'78 Default Slider 0.850 210 90 0'88 0'78 Default. Slider 0:850 210 90 0'88 0'78 Default Slider 0'850 210' 90 0'88 0'78 Default. Slider 0.850 210 90 0'88 UL78 Default Slider 0'850 210 90 0-88 0'78 Default Slider 0.850 210 90 0'88 0'78 Default Slider 0'858 210 98 0'88 0'78 Default. Slider 0'850 210 SD 0.88 0.78 Default Slider 0.850 300 90 0'88 0'78 Default Slider 0'850 300 90 0'88 0.78 Default Slider O'850 300 90 0'88 0.78 Default. .. ., .. t' f �l.� •.ti moi: ..�.'f� .. 1 ' f ' � FY �1 � �J • .. .. .+ _ 1 . S r .t . r. � . :�7 ^ JP i l � .. . '.k S l �:'� 1 ... Y„y7 � � . Y A_ l''-'. .'� .. .. x ... .. � .. r .r y ... .. ' 4. ,. � .. l � Y f, S _ .. C . � .. 1 i• ♦ �. o .. 1.. � . y .. .. ) .. .. 1 POINT SYSTEM Page 4 P -2R Project Title.......... Crespo Residence Date........ 03/14/95 MICR.OPAS4 v4.02 File -C7795 Wth--CTZ1 1592 Program -FORK P -2R User* -01035 User --Narrow Gauge Consulting Run. -.Lr -arson 7795 OVERHANGS AND SIDE. FINS --- Window ...:...... ------ --- Left Fin --- --- Right Fin -.-- Area Left Rght Surface (sf) Hght Wdth Dpth Hght. Ext Ext Ext Dpth Hght. Ext Dpth Hght. HOUSE 1 Window 30.0 5 n/a 6 0 n/a n/a n/a n/a .n/a n/a n/a ra/a 4 Window 8.0 4 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 5 Window 8.0 4 n/a 2. 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 16.0 4 n/a 2. 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 1.6.0 4 n/a 13 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 40.0 6.5 n/a 2 1 n/a n/a n/a n/a n/a. n/a n/a n/a 9 Window 12.0 4 n/a 12 0.5 n/a n/a n/a n/a n/a, n/a n/a n/a 10 Door 40.0.6 n/a 12 1 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 6.0 3 n/a 12. 0.5 n/a n/a n/a n/a n/a n/a 'n/a n/a 12 Window 24.0 6 n/a 17 0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Door 53.0 6.5 n/a 17 0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 16.0 4 n/a 2 0.5 n/a .n/a n/a n/a n/a n/a n/a n/a 17 Window 18.0 3.5 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 18 Window 6.0 1.5 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 19 Window 17.0.3.5 n/a 2 0.5 n/a n/a n/a n/a n/a n/a n/a n/a THE R.MAL MASS Area Thick Heat Conduct..- Surface Mas:; Type (s f) (in) Cap iv i t.y , R--v,-a lue Lor..at i on/Corrsnent.s HOUSE 1 Int.eriorHor% 17 4.0 21.0 0.59 k-•0..0 horizontal hearth 2 Inter i or -Vert 48 4.0 21.0 0.59 R --0.Q vertical hearth 3 InteriorHorr 120 1.0 24.0 0.67 R--O.O counter tile 4 Inter i o'rVert 200 1.0 24.0 0.67 RnO.O vertical tile HVAC SYSTEMS Minimum Duct Duct. Duct. System Type Efficiency Location R --value Efficiency HOUSE Furnace 0.780 AFUE Crawlspace R--4.2 0.830 KSplit 10.00 SEER Crawlspace R--4.2 0.860 WATER. HEATING SYSTEMS Number Tank External in Energy Sire Insulation Tank Type Heater Type Distribution Type System Factor (gal) R --value 1 Storage Gas Standard 1 0.60 50 , R-12 POINT SYSTEM Page 5 P -2R Project Title .......... Crespo Residence Date........ 03/14/95 1 MICROPAS4 v4.02 File—C7795 Wth--CTZ11S92 Prograrrr-FORM P -2R Usert-•MP 1035 User—Narrow Gauge Consulting Run—Larson 7795 _.._......._.__._._—.._........_._...._._...__._......._.._._._.._.._._._.._....__..---..._.__....__.____...__.._...._.....__._..._.__._.._. SPECIAL FEATURES/REMARKS Mote: Habitable square footage for energy compliances may Vary from measurement for other purposes. Ceiling Ins: Minimum R:30 Wall Insulation: Minimum R19 Floor Insulation. Minimum R19 Water Heater: 50 goal. max.. / Gr=as / CEC 'approved . . . . . . . . . MINIMUM ENERGY FACTOR = 0.60 . . . . . . R12 external wrap required -- NOTE: ' . . . . ." . . . . . Be sure wrap is. installed in accordance . . . . . . . . . . with Prop. 65 Toxic Warnings label . . . . . . . . . requ i rements Thermal Mass: 385 s f minimum thermal mass required per plan Glazing: 413 sf max. / Metal fr=ames / Maximum U --•values: . . . . . . . . . 0.85 (MFRC labels required) Heating: Minimum AFUE 78 Cooling: Minimum SEER. 10 Ducts: Minimum R4.2 in crawlsp,pace W HVAC SIZING Page 1 HVAC Project Title.......... Crespo Residence Date .......... 03/14/95 Project Address........ Heideco se Lane Chico Documentation Author... Patricia Chaix il1--TV i ng -Perm i t -i Company.... ............. Narrow Gauge Consulting -?- Telephone .............. (916) 274-2033 Fan Checi Date Compliance Method.....'.. MICROPAS4 by,Enerco&p, Inc. 1 field CheckThate Climate Zone........... 11 ... ... . ...... MICROPAS4 v4.02 File -C7795 Wth-CTZ11S92 Program -HVAC SIZING User#"KP1035 User -Narrow Gauge Consulting Run-Laison 7795 GENERAL INFORMATION Floor Area ................. 2648 sf Volume ............. ! ....... 22550 cf Front Orientation.......... Front Facing 30 deg (NE) Sizing Location..: ......... CHICO EXP STA Latitude ................... 39.7 degrees Winter Outside Design...... 27 F Winter Inside Design....... 70 F Summer Outside Design...... 102 F Summer Inside Design...... 178 F Summer Range ....... ....... 37 F Interior Shading Used...... No Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction ... ... 0.2p HEATING AND COOLING LOAD SUMMARY Description Opaque Conduction and Solar...... Glazing Conduction ............... Glazing Solar.' . .................. Infiltration._....... ;V ........... Internal Gain .................... Ducts............................ Sensible Load .................... Heating Cooling (Btuh) (Btuh) 14.032 6665 15095, 8425 n/a 11625 14260 4686 n/a 2550 4339 1698 47726 35649 Latent Load ......... ...... ..... n/a . 7130 ---------- ---- --- Minimum Total Load 47726 42779 Note: The lolds shown rare.onlyone of 'rr the citeia affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, overs i'zing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Mandator,/ Measures Checklist: Residential MF -1 R NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION DESIGNER I ENFORCEMENT Building Envelope Measures • §150(a): Minimum R-19 ceiling insulation. X §150(b): Loose fill insulation manufacturer's labeled R -Value. X • §150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). ' §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. X §150(1): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 permfinch. N/A §118: Insulation specified or installed meets California Energy Commission quality standards. Indicate type and form. X §116.17: Fenestration Products, Exterior Doors and InfiltratioNExfiltration Controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufacturad fenestration products have label with certified U -value, and infiltration certification. X c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed. §150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. §I 50(f): Special infiltration barrier installed to comply with §151 meets Commission quality standards. §150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control X 2. No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §110-13: HVAC equipment, water heaters; showerheads and faucets certified by the Commission. X §150(1): Setback thermostat on all applicable heating systems. §1500): Pipe and Tank Insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating secticns of hot water system. X 4. Cooling system piping below 55°F insulated. 5. Piping insulated between heating source and indirect hot water tank. ' §150(m): Ducts and Fans 1. Ducts constructed, installed and seaied to comply with UMC Sections 1002 and 1004; ducts insulated to a minimum installed value of R•4.2 or ducts enclosed entirely within conditioned space. 2. Exha::st fan systems have backdraft or automatic dampers X 3. Gravity vent?aging systems serving conditioned space have either automatic or readily accessible,. manually operated dampers.. §114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light rX System is installed with: a. At least 36' pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa X Pool system has directional inlets and a circulation pump time switch. §115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously buring pilot light (Exception: Non -electrical cooking appliance with pilot < 150 BhAr.) X Lighting Measures §150(k): 40 lumenswatt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. X Revised January 1992 LAND DEVELOPMENT - BUILDING PERMIT CLEARANCE Building Permit No. 7 © / OWNERS A.P. NAME: Oy-eS120, NUMBER: PRINT LAST NAM FIRST COUNTY ZONING DESIGNATION: SJ? I FLOOD ZONE: FLOOD MAP: i APPROVED: CONDITIONALLY APPROVED: RESOLVE PROBLEMS PRIOR TO APPROVAL: PARCEL CREATION BY DEEDS DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION COMMENTS/CONDITIONS: LEGAL ACCESS REQUIRED: YES NO YES NO PARCEL CREATION BY MAPy DATE OF RECORDING LOT BOOK elf PAGE 47149 COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BUILDING DIVISION UNLESS OTHERWISE NOTED. X 1. Maintain a 50 ft. building setback from centerline of road. X 2. Maintain a a2C7 building setback from rig ht -of -way/ee e -of Cu.1— CGe — .rae-- A— 3. Pay water tender fees in the amount of $ Z O to Battalion Number i of the Butte County Fire Department. 4. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. _ 5. Pay T.D.D. (Thermalito Drainage District) fee in the amount, of $ 6. Maintain a 100 ft. leachfield setback from all existing wells. 7. Maintain a ft. leachfield setback from 8. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. 9. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to the Planning Division. 10. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. 1 1. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. 12. CHECK APPROPRIATE REQUIREMENTS YES OR NO OR CONDITION NUMBER. LD 12194 - CAWP511F0RMS.KI8LDGPERM.CLR ,00SjuawdoiaAeO rl"-' 5661 v T W� 3une io i,: 1 -,. /RESIDENTIAL 047-320-061 PERMIT#95-2436 A CRESPO, Raffael ` ! 14031 Heidirose Ln., Chico �Cont: Frank Koulczyk Y " New Pri Det Garage yy..� - .. JOB FINALED (Date) y 11-6 Signature `l • d-L�M d=OK O = Not OK - = Not Applicabler f; • =Not Ready MOBILE HOMES""' Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements y 3z 2. Soils; Special MH Support Sketch " } '- - .r 3. Sewer; Location -Test -Fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Gmd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / P'L" ft. / /"Nat. or/ P L" ft./ P'LPG 7. Well Clearance & Disconnect --',8. Utility Clearance = Date . Card B-1 Date . Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test-Demand-Valve—Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Orain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval S. Gas and Electricity Tagged 9. Exits;'Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 --MISCFLLANEOU^S_...:.r (/fGs P!Footings: Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs.-Connectors _ Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors L+le c.-.... ,• . r ils-Anchors-Studs-Rftrs-Trusses Ctogiding: Nailing -Veneer -Stucco -Mesh //- -q,6 1 oof; Shthg-Roofing 1-ExT.'Teps-Doors-Landings Date // (j 415- Card B-1 kV Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except It's 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting. Distances-GFI 5.Elec.; Pool Lighting; 15 volts-GFI . . 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.: Cir. Test -Water Supply Test Date Card B-1-- Date Card B-1 Date Card B-1 Date Card B-1 -j=OK O = Not OK = Not Applicable Not Reedy RESIDENTIAL (: • = pate UNDERFLOOR (Plans) OK except k's - 1. Zoning -Setbacks -Easements -Flood -Slope' - - 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wrapped 6. Stemwalls, Garage: Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe: Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts: Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except ti's 16. _Water Htr.: Vent -Access -Combustion Air -Baffle _ - 17. Water Pipe: Test & Anchor -Nail_ Protection - 18. D.W.V.: Test -Fittings & Anchor -Nail Protection ------ -------------- ----19.-Shower -------_19.Shower Pan: Test. First Floor -Tub Access ---- -- ---- 20. Test Tub & Shower. Second Floor -Tub Access 21. Gas Pipe: Size & Anchors Date Card B -t Date Card B-1 ----------------- ---------------------------------------- Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except a's 22. Fixture& TransformerClearance-Ins. Protection __ __ 23. Elec. Receptacles Spacing -Lights & Switches at Doors -------- -- - -------•----------------- ---------------- --------------- 24. Size Boxes & No. of Conductors -Stapled --------------------------------------------- ----------------------------------- 25. Romex Installed Close to Edge of Studs & C.J. --------------------------------- - ----------------------------------------------- 26. Equip. Ground made up-w•Mech. Fastners-Bond Gas & Water ---------- -------------- ------------------------------ ----------------- 27 2 Appliance Circuts in Kitchen & Conductor Size,GFI --------------- ------ --------------------•--------•----------------------------- 28. Subfeed Wire Size ga. Cu or AI-A.C. Wire Size ' ga. Cu or Al --------------- ------- ---------------------------------- 29. Range Circ. ' • ga. Cu or AI -Oven Circ. / r ga. Cu or Al. Insulated Neutral O Yes- O -No --------------------------- - ---- ------- ---- -- ---------------- 30. Service -Riser Conductors & Ground -Main Disconnect - --------------•----------------------•-------------------------------- 31. Equip Clearances Panels -Motors -Meth. Equip. --------------------------------- ----------------•------------------- ----------- 32. Clothes Closet Light -Shower Light -Spa Light ------- - - - - -- -- -- - -- -- - - 33. Smoke Detector Date Card B-1Date Card 8-1 --------------------- _-------- - --•-----------------•-------..-... ---------- Date Card 9-1 Date Card B-1 Date MECHANICAL tPermrtl OK except a's 34 A.C. Ducts Insulation & Support ------------------.....- 35 Vent Fan: Exhaust above insulation ------ --•------ - - -- .._..-•------- --- 36. CondenFate Drain & Overflow. Size & Grade ........... .................... ... .... .. ... ....._ 37. Frrrnance-Vent: Access -Comb Air -Return -Air. Vent -115 outlet 38 Attic Access & Platform if Furnance in Attic ---- -- -- -- -- - Dare Cord 8.1 Date Card 8.1 Date Card B -i Date Card B -I Date FRAMING iPlansl OK ,,xccut .r s 39 Sits. Proper Material & AnChnrs JO Walls Sbids-Namnq Sp rcurq d Bracinq-Ptates-Sound . •11 Bearinq Wails over Gii leis & Flour N: iliny . .. J2 Diall Stup in Walls :rat prrnill .. -13 Fmm Stupe Furn;rl Cuihn,ls-51:ur (:bases -jun .. _... JJ H,•ar1,•r; .S Beam-`ir [�t : li,tarwrl - .. . jingle & Duplex) Date FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors r 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Rfng. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access: Size 8 Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions _50. Garage Fire Protection Framing 51. Property Line firewall & Openings Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits - 53. Stairs: Width -Headroom -Rise -Run -Landing -Fire Protection _ 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access - 57. Glazing Area -Glass Protection -Skylights -Plastic 58. Shear Walls; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows Date - Card B-1 Date Card B-1 Date - Card B -t Date Card B-1 Date FINAL (Plans) OK except a's 61. Ext. Steps -Door & Sidelight Protection -Landings 62. Smoke Detector --------------------- - 63. Furnace: Vents -Clearance -Comb. Air -Connector - In Garage: Above Floor -Ducts -Meth. Protection ------------ -------------- 64. Bedroom __ _ 65 G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel: Breaker Sizes & Labels --- ------------------------ 67. Stairs & Rails -------------------- 68. Fireplace or Stove:_ Clearances -Hearth 69.Elec. Outlets at Wood Panel: Int. & Ext. -- ---------------------- 70. Kit.Fixt_ & Appliance; Grnd.-Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter ---------- --------------------- 72. Garage Fire Door: Swing -Landing -Closer -------- ------------------- 73. A.C. Duct in Garage -Damper ----- --------------------------------- 74. Wtr. Htr.: Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage: Above floor -Meth. Protection 75. Plb. Elec. & Mech. Equip. Listed for Location 76. Elec. Receptacles in Garage: (G.F.I.)-Romex Protection ---------------•---------------------------------- - 7,_ Insulation -Foam -Looked in Attic CIYes 78. Guard Rails & Deck Construction -Post Caps -------------------------------------------- - 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes ------ ------------------------------- 80. Following instld.: Drive 0 Yes ❑ No: Walks ❑ Yes ❑ No; Planters ❑ -Yes---O--No al. Stucco: Brown -Finish ----------------------------------------------------- a2. A.C.Unit Disconnect Electrical Plumbing ---------------- ---------9-_-pP-------- - a3. Vents Above Roof: PIb A Trance -Fireplace. -Clearance to Openings - ------------------------------------- a4 Water Well: Disconnect. Electrical. Plumbing ...... ... ... ..--- --------------------------- ----� 85 Exterior Elec. Trim: G.F.I. Receptacle -Underground ... _ . ...... _ _- - _ . - --- ----- ------------- ------- 86 Ventilation Throughout House .. ... ... .. .. ... ---- ---------------- ------------- 87. Glass Protection 88 Corrections from Previous Inspections - - - - -------- ---------------- - 89 Gas T,:st-Meters Tagged: Gas -Electric ...... .. _ - ------------------------- 90. Water & Sewer Connected -C 0 to Grade -HD Approval ... . - -------------------------------------- 91 Energy Compliance Certificate -Other Certificates -------- -------- ---- Date Card 11-1 Data -- -------Card B_1 -- Date C.ud 6-1 Date - ----- Card B_1 - - C Date Can? 8-1 Dire Card B-1 Comments at Final: COUNTY OF BUTTE - ._:, ' 7 .County Cente �t DEPARTMENT OF DEVELOPMENT SERVICES-BUILDINGDIVISION V Drive - Orovillei California 95965 - Telephone (916) 538-7541 PIT NO. APPLICATION AND PERMIT 25 CS ASSESSOR PARCEL NUMBER 0477320-061 ZONING SR1 BUILDING PERMIT OWNER RAFF�AEL CRESPO TELEPHONE SO, Fr, OCC. BUILDING VALUATION 5 0 � , OWNERS MAILING ADDRESS 14031 HEIDIROSE LPI-CHICO, 95926 CONTRACTOR'S NAME FRANK KOULCZYK TELEPHONE CONTRACTORS MAILING ADDRESS 15728 THIEL WAY GRASS VALLEY 95949 Fireplace CONSTRUCTION LENDER NOTE \, UNINOWN Total Valuation Is Filing Fee $ 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 12Q .00 ARCHITECT OR ENGINEER NONE LICENSE NO. Plan Checking Fee $ 81.90 Energy Plan Checking Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Penalty $ BUILDING ADDRESS -- "-` 14031 NEIDIROSE LN PERMITFEE $ 227.90 CHICO 95926 PLUMBINGPERMIT Filing Fee 20.00 Each Trap 7.00 LOT NO. SUBDNISION'SNAME PARCEL MAP Solar or heat pump water heater 23.00 f USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other PRIVATE DET. GARAGE SPECIFY Water piping 15.00 Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 9n X 9R Mobile Home S G W 920.00 PERMITFEE g Contractor ELECTRICAL PERMIT Filinq Fee 20:00 Main Service EOOV OR LESS ( zooA OR LESS ) 23.00 Main Service ( 200A TO ,000A ) 46.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in f II force and effect. License Class Lic. No. 333 773 OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason NEW CONST. DWELLING OCCUP. SO. 19.60 OR ACDNS. ( 8 ACC. ) 3.SQ FT. NEW CONST. MULTI.OUTLET UTLE NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS 8 SINGLE OUTLET CIR. Ex. Occup. (OUTLET OR FIXTURES 2U O I•50 B^L Ex. Occup. ouTLEEDrsPaE o.�ea ( ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE $ 39.60 Contractor WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier.aA d policy number are: Carrier -5Th, %� ���/Uj� __ MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE S Contractor Policy Number Q 3 ,��% (The above sections need not be completed if the permit is for work Of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers compensation laws of California, and agree that if I should become subject to the workers' compens ion provisions of section 3700 of the Labor Code, I shall forthwith comply th tho provi ' ns. X r _Date � shp — Signature of Applicant - Owner Contractor ❑ Agent An OSHA permit is required for excavations over 50" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee Is Occ CONST. TYPE TOTAL FEE $ 267.50 HA2. _. D. FEES _ IMP FLOOD , — X CDF PARC0. PD HD V ISSUE! V/ This permit is hereby issued under the applicable provisions in the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. /L BY Date `0 lo �6 (Date) Receipt No. J 1S / < 3 1PERMITEXPIRESOKII WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR G LDENROD-APPLICANT I - i *..i. . COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1. 1469 Humboldtlpad, ,-Kfco, CA - (916) 89.1-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE CQksa0 Ci 5--Z-11-56 OWNER PERMIT NO. A routine inspection mdi Yes that the following violations of Butte County Ordinances exist at the above address should be corrected. Please notify this office when correction of work is completed. If u have any questions pertaining to this matter, or need additional explanation, please con this office immediately. –/-// S101"IV4 Ox -i Date I I —Z 9 j Inspector REV 10/92 .-,,;;OUNTYOF BUTTE - DEPARTMENTOF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 -TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER Ct F 1 i^C� S �O w P. o. 0 P Proposed Building Use �r-,C! (`Gt 4 F Building Inspector Date r At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. /0 14. 15. 16. 17. 18. 19. 20. ". 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. t All items have been submitted . ........................................ Plot plans, 3/4 sets, signed by preparer of plans . .......................... Complete plans, ;3/4 sets, signed by preparer of plans . ..................... . Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. Hazardous Material Form . ............................................ Energy Design kCompliance and supporting documentation . .................. Statement of Intent for Non -Heated and A/C Buildings . ...................... Engineered truss details and layout in duplicate (required prior to plan check): 4�.. . Mobilehome datand m ufacturer's installation instructions, 2 sets..��. ... . Fees of $ f'O _. r .�........... . Impact fees as'shown on attached schedule. .... �g�? t V .:......... . California Department of Forestry plan approval/fees. 19 .. ��.:.`......'........ re s Flood elevation letter (100 year flood �jy�California Engineer. y ........ . Sanitation and plot plan approval Health Department . ............ City of Chico plumbing permit. .............................. Plot plan and business license,approval from City of Biggs/Gridley. ............. Planning approval for (A) Use: • '� (B) Parking: ......... Contact Land Development.about (A) Improvements (B) Drainage. .......... . Driveway permit (construction approval.required prior to occupancy). . . � K" �� Pre -Inspection requ� Pre -inspection for Ck .k. required. . to Building Inspector (Date) Contractor's license information. (No., Name Style, Classification) . .............. Certificate of Workmans Compensation Insurance . .......................... Owner -Builder Verification (Given to owner , Mail to owner ......... :.. - Recorded copy of Agricultural Acknowledgement Statement . ............ • . Letter of signature authorization .................................... Copy of recorded deed of parcel creation and 60 right of way to a public road. .. `.. . Letter of intent on building use . .......................................... Mobilehome utility clearance . ..................:......... `.............. . Documentation of legal access . .......... .......... :.................. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... Existing violations/expired,permits....................................... . Plancheck list . ..................................................... When you issue the permit, process As follows: Mail to owner. Mail to contractor. Telephone and hold for pickup at Orn office. Deliver with inspector. Other Parcel Creation Acreage Applicant Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date s> By The following data must be submitted prior to permit i s ance: (Circle new item not checked"< 1. Index permit for above items No. d- 2. Additional items required: -Sem- (. Z Contractor, designer, owner, was advised of above required data by _ phone _ mai-( Counter by _ Date onC- ria or, designer, owner, was advised of above required data by _ phone _ mail oun er by _ Date Plans checked by Date Plans approved by Date Sets of plans on hold in Jfile cabinetf/t�,a"� :. f. )AP folder Copy - Department of Public Works w 'r t .../ TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance R.H. USE QM Plot Phm Athchad Floor Plan ABached, Sem to B.D. ft/a.- go Crete d ate/ f d A.3,e 4, <f7-`32- 4 / Owner /Location / Plan Approved for: Sewage Disposal lWater Supply: Public Private Well I/ Clearance for -bedm obi fie. Other 4,ri� Hold final for: Final clearance O.K. for: NOTE: Environmental lieale Specialist Date 8/92 3i ^"Yr`' c� ♦ .. •�- ,y�rr�yrgr.� .{ i}�'" .,y.x.viy-�1r'�hT4'�/T�'.:7G: �'s.. vw.��.i v<y.� 41.:� `::cw•p+rty �..�'_.j{ .'�`j''`'+�.. �4'1•°lL:a':. ,_._w yfs'�x'� �. ,.:� .s '" A , vxS • OVI COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION - 7 County Center Drive - Oroville, California 95965 - Telephone (916) 047-320-061 538-7541r,,�,, .� P o• APPLICATION AND PERMIT . �--5_- ""�°0p°"°�N11°�" SR1 BUILDING PERMIT owNER RAFFAEL CRESPO 1Ta�,oNa SO. Fr. OCC. BUILDING VALUATION OWNER'S MAVNG MORES 14031 HEIDIROSE LI'i CHICO 95926 COWRACM" NAIL!ONE FRANK KOULCZYR . CONTRACTOR'S A ADOP 15728 THIEL WAY GRASS VALLEY 95949 �F�jreplacoCONSTRUCnoNLENDER NONE UNiOROWN Valuation $ Fling Fee S 20.00 LENDER'S MAILING ADDRESS Permit Fee $ 12 ARCHITECT OR ENGINEER NONE LICENSE NO. Plan Checking Fee $ 81.90 Energy Plan Checking Fee $ ARCHITECT OR ENGNEERS MAILING ADDRESS Penalty $ eULDNG ADDRESS 14031 NEIDIROSE LN PERMITFEE $ 227.90 PLUMBINGPERMIT Fling Fee 20.00 CHICO, 95926 Each Trap 7.00 LOT NO. LOT NO. _P SUeONISION�NAME PARCEL MAP Solar or heat• pump water heater 23.00 Water piping 15.00 . USEOFSTRUCTURE SF O Duplex ❑ Mobilehome ❑ Other PRIVATE DET. GARAGE SPECIFY Each gas water heater or vent 15.00 Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 TYPE_ .F__WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: gn X 9R Mobile Home IS I GI W1 @20.00 PERMITFEE S Contractor ELECTRICAL PERMIT Filina Fee 20.00 - "0" OR LESS _ Main Service ( 200A Oa LESS ..., ... _ ....... ... -- 23.00 Main Service ( 200A TO 1000A ) NNEW�COOtS T. ( DWBE� G OIDCSUP. ) 3. 46.00 Se FT: 19.60 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in VI force and effect License Class Lic. No. 333 77 3 OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, army employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project O I am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' cooSmpensatio surance carr a d policy number are: Carrier /%% % _ Policy Number Q .S (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued. I shall not employ any person. in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the . workers' camp . on provisions of section 3700 of the Labor Code, I shall forthwith comply th tho rovi ' ns. �G r Date X � — Signature of Applicant - Owner Contractor Cl Agent An OSHA permit is required for excavations over So' deep and demolition or construction of structures over 3 stories in height NEW CONST. MULTI. CUTLET N0µR 10 ( CIRCUITS ) @7.50 POWEa APPAfiATUS WER (a SINGLE OUTLET 010. Ex. Occup. (OUTLET OR FOTTUaEs ) 2013 1•00 BAL Ex. Occup. FIXED APPLNs. OR p (OUTLETS (RESIO.) EA) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMITFEE S 39.60 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMITFEE S Contractor Mobile Home Installation Fee Is Energy Inspection Fee Is Occ CONST. rPE TOTAL FEE $ 267.50 I HAZ. 0. FEES I I -MP FLOVOO I COF PARCEL Po HO i SSUE A -� This permit is he, issued under trio in the Butte County Code and/or indicated above for which fees have By PERMITEXPIRESON applicable provisions Resolutions to do work been paid. Date (Date) – Receipt No. WHITE-O.O.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT CDF FIRE SAFE REQUIREMENTS 04�- - 320 - 06 cj.S = 2� 3 �.�'e5 0 ��f C e 1 AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte.County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. �] 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards �L] 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other appirte�ant'structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. 1 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [ 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [� 2. The length of ver-*:-i^curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [6] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [ 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. 1270.10 Width. All driveways shall provide a minimum 10 foot \ traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of :3.-, 04� -320 - 06 ( q5 -2 q3(, C'e5pp, kaffae AP # PERMIT # NAME [ J 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. 1273.10 Turnaround. A turnaround shall be provided at all // building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [�] 1. Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. [ 1. All parcels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ul] property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. 1276.02 Disposal of Vegetation and Fuels. Disposal, including / chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction Dr fi_ial inspection of a building permit. Page 2 of 3 -32-0-o61 q'5-2-43(, ere 5po, FFG-� AP # PERMIT # NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [ ] If Building Setback is Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed lot of wall area toward property line with insufficient setback -.Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry. Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3