HomeMy WebLinkAbout056-380-003 80MIC PIERS ! PRDCASr CONCRETE PADS OUTLINE OF 1009112 COACH ' Z4 . VR GO PLAN DOUBLE WIDE MOBILE COACH Scale: 1" = 10' NOTE: FOR MORE THAN TRIPLE WIDE UNITS, SUBMIT LAYOUT TO THARP k ASSOC. FOR APPROVAL. 13TANDARD PIER & LOOTING SPACING PER MOBILE HOME MANUFACTURER'S DISTAUATION MANUAL CONFIGURATION SHOVN 1S THE MINIMUM NUMBER OF PADS REQUIRED. I • SOSMIC CONCRETE OUT OF Ma a �SINGLE HIDE TYPICAL •-12' or 14' PLAN SINGLE WIDE MOBILE COACH Scale: 1" = 10' Nol 19T NDARD PIER A /'DOTING SPACING PER MOBILE HOME MANUFACTURER'S INSrAU ATTON MANUAL CONFIGURATION SHOWN 1S THE MINIMUM HUMBER Or PADS REQUIRED. . ELEVATION NOT TO SCALE tu THE FOUNDATION SYSTEM 1S SAFE FOR INSTALLATION IN FLOOD PLAINS UPON REVIEW AND APPROVAL BY THARP t ASSOC. • This set 0" Plans aw-i speciiicatioms MUST be kept on the job at all times and it is uydawlW W make anY changes or alterations 01) same without "T-itten permission from the Department of Public Works, County of ]Butte. M t/ a x M prRrroa oN ro. »tlewo aurw*rn • 2 - 3/8' x 1' BOLTS FIELD DRILL HOLES OPTION OF 4 - N14 TEX STS COACH C OR J BEAM 1/4'x2'x3' x 3' 4' PLATE ANGLE 3' WIDE � � 4 - 1/2' J SEISMIC BOLTS ,� PIER TYPICAL BEAM CONNECTIONS Not to Scole O 4- COACH 1 BEAM 3' X 3' PLATE ar pa +0 4 - 3/B` MAX TUBE HEIGHT BOLTS 8' SHORT TUBE h 14' LONG TUBE 2- DIA STD PIPE w ~ BOLTSO 3/16' PLATE LIGHTEN TO 180 CLAMP IN -POUNDS .4.. TORQUE 3/4' THREADED 3/16' PLATE LEGS ROD TTP Of 4 • 5/16' PLATE 5/8' X 1 1/4' BELT WITH HARDENED VASHER SEISMIC PIER Not to Sole CP - SE)Smic PIER 01 - PATENT PENDING IMIE1 190 IN -POUNDS 1S EQUIVALENT TO 13 FT -POUNDS 1$ So )N OVERSIZE FOR LMRING �- AND O+ CORNER SREAKAM • •1 a 1NsERT F ys' a 1 1/4' N.S 8' 240 �+- 36 1/2' -� 5/B' 11 1/8' FLANGE StA1NLESS StEE1 ANUaR MSERT 3.5' 4l4 -1r4 %M FF 1 + j . , PRECAST FOUNDATION PAD SCALE- 1' • 1.3' XTU112.- 'll Materials & T orkma,nship Sha11 Be lE Accordance with Recognized Good Practices and of a Quality Prescribed for the Specified use In t2ae'Uniforan Building, Plumbing & Mechanic.; Codes and the yati_onal Electricei Code. GENERAL NOTES: REFERENCE: CAR IFORNIA CODE OF REGULATIONS. TITLE 23 AND U.B.C. 1994 EDITION. 1. DESIGN LOADS;: COACH VERTICAL LIVE LOAD LATERAL LIVE LOAD SEISMIC SIZE ZONE ROOF fI00R WIND EXPOSURE SINGLE W1DIE 30 pd 40 pd 70 mph B 4 DOUBLE WID)E 30e 40 e =80 C 4 2. THE DESIGN UOADS SHALL BE CONSISTENT WITH ROOF LIVE LOAD, WIND LOAD. AND SEISMIC ZONE AS ESTABLISHED IFOR PERMANENT BUILDING WITHIN A SPECIFIC LOCAL AREA 3. ALL FOOT D40S ARE TO BE SUPPORTED BY FIRM. UNSATURATED. UNDISTURBED COHESIVE SOIL, FOOTINGS ARE DESIGNED FOR 1000 PSF TOTAL LOAD SOIL PRESSURE AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. 4. CONCRETE: 31000 PSI AT 29 DAYS AS TESTED AND MANUFACTURED BY STARL.ITE WEIGHT CONCRETE. S. STRUCTURAL STEEL: A. SMALL CONFORM TO ASTM A36 F, - 36 KSI MINIMUM. b. SMALL BE FABRICATED ACCORDING TO AISC SPECIFICATIONS. C. SHALL BE WELDED ACCORDING TO AWS SPECIFICATIONS: i. ELECTRODES: E70 R. PLATES: ASTM A36 ilii. ANCHOR BOLTS: ASTM A307 JW. BOLTS: SAE GRS=ASTM A449=ASTM A325 V'. THREADED ROD: COLD DRAWN LOW CARBON WELDABLE d. ALL MEI'ALCOMPONENTS INCLUDING NAILS A SCREWS ETC. ARE TO BE PROTECTIVE COATED. 6. THE PIER AND RIDGE BEAM SUPPORT ASSEMBLIES SHALL BE COATED WITH SHERMAN WILLIAMS E61 -RC2 OR APPROVED EQUIVALENT AND SHALL BE LISTED AND LABELED BY CERTIFIED TESTING AND CONSULTINO SERVICES (CTC) FOR THE FOLLOWING LOAD: A. LATERAL: 1700 b•. MAX b. VERTICAL: 13000 biL MAX 7. THIS FOUND&TION 1S FOR PLACING MANUFACTURED BLnLDINGS CONSTRUCTED WITH LONGITUDINAL OR CROSS JOINTS. 9. THIS FOUNDATION PLAN IS DESIGNED TO BE CONSTRUCTED (N` A FAIRLY LEVEL SITE WITH NO EXISTING SOIL PROBLEMS, IF' SETTLEMENT OCCURS DUE TO POOR SOIL, SEE NOTE 11. 9. PRECAST CONCRETE PAD SHALL BE PLACED ON LEVEL UNDISTURBED SOIL. 10. PAD ORIENTA'.TION MUST BE AS SHOWN IN DRAWING. THIS SHEET. 11. IN AREAS WIHERE DIFFERENTIAL SETTLEMENT (D.S.) CAN OCCUR, MANUFACTURED HOMES SHALL. BE READJUSTED WHEN D.S. EXCEED 1/4', OR WHEN IT WILL ADVERSELY AFFECT THE USE OF THE MANUFACTURED HOME. 12. THIS SYSTEM IS ADAPTABLE TO STANDARD HOLLOW MASONRY BLOCK PIERS. COACH LENGTH NOTES: 1. MAXIMUM LENGTH OF SINC.IE WIDE COACH - 6a FEET. 2. MAXIMUM LE:NOTH OF DOUBLE WIDE COACH - 70 FEET., 3. FOR TRIPLE WIDE COACHES, FOLLOW SAME PLACEMENT PATTERN AS SHOWN ON THE DOUBLE WIDE MOBILE COACH. 4. FOR ANY COACH SIZE OTHER THAN AS SHOWN ON THIS PLAN OR REFERENCED ABOVE, THE PIER AND PAD LAYOUT SHAllL BE REVIEWED AND APPROVED BY DONALD M. THARP A ASSOCIATES. pEAM SIZE MOTES: 1. SPACING SHOWN ON THIS PIAN ARE FOR COACHES WITH 10- AND 12- BEAMS. 2. ANY S- BEAM IS NOT TO CANTILEVER MORE THAN 6.0' ON EACH END OF UNIT AND SPACINCI OF SEISMIC PIERS CAN NOT EXCEED 13.5'. ,nuwt•+oe•t i�7LA*cu.Iru. f►1ltw. AFAtrtt AND SAFM COO( SEC -T"4 ta"I A P P R O VE D SUBJECT TO C!MRECTNY•+S NOTED yprovol do*, r.o• ovthonse or oppro..t cs,.• omasron o• dlriolit. 4oT �•r�,....w.+.rs o� oppl.cab7e Srore luw, v.'. ryvbwere+ State of Cf:il!Y"a DepornnMa o! )k-vsinc and CommvrOe Devekn~4 OIV15rCJCM4XS ANSTANr)ARDS BY !WC)olt 10401:� i SPA. N0. --3a -65------------- ,%;% Pian A. ,'rowel Exc im -LY9`i -17 Bu� @ ._s+e 1 iy C um I I 0r CAl'�0 BUIDNG DEPARPfl, IPPR FILA Mp RENEWAL OF STATE SUBMITTAL 30 -SF REVMK MS SY 10/08/96 11/06/96 YID a W a co O 4- N ar pa +0 • !r L7 �U 60 h 'b w h a to .4.. a W a Date 09/10/96 scala As Shawn Drawn YMD Job 95-36 Shoot 1 of I shows h z 0 U 0 p� M a 0Uc op fV O 00 W C4 �] z^�a Q N � Date 09/10/96 scala As Shawn Drawn YMD Job 95-36 Shoot 1 of I shows