Loading...
HomeMy WebLinkAbout058-440-008058440-008 99-1894 BAKER, ROBERT & PATRICIA 190 S'T'ORM MOUNTAIN DRIVE.ORO 'ONTR: D Xe D 1-IOMH5 MI -I ON PEW FND, NE SITE �,'17ai �i� I��• l"1�� � j36`b- t�� t BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION (IVR): (530) 538-4365 OFFICE: (530) 538-7541 FAX#: (530) 538-2140 ONLINE PERMIT/RENEWAL PAYMENTS: www.buttecounty.net\dds PROJECT INFORMATION Site Address: 3540 STONE MOUNTAIN RD Owner: Permit NO: B08-1814 APN: 058-440-008 BAKER, ROBERT Issued Date: 9/22/2008 By GLB Permit type: RESIDENTIAL 3540 STONE MTN RD Subtype: SFD-Mobile Home PFS OROVILLE, CA 95965 Expiration Date: 9/22/2009 Description: NEW MH EX SITE PERM FND 1350 (530) 210-8582 Occupancy: R-3 Zoning: FR10 Contractor Applicant: Square Footage: FREEDOM HOMES FREEDOM HOMES Building Garage Remdl/Addn 2243 FEATHER RIVER BLVD 2243 FEATHER RIVER BLVD 1,350 OROVILLE, CA 95965 OROVILLE, CA 95965 Other Porch/Patio Total (530) 532-3301 (530) 532-3301 1,350 FEE INFORMATION DBEH Building Review Fee $78.90 DBF MH Plan Check $241.16 DBFIRE Fire Inspection (SRA) $107.00 DBFIRE Fire Inspection (SRA) $107.00 DBFIRE SRA Fire Plan Review (S $107.00 DBMSC Mobile Home Permit Fee. $361.74 DBOMSC Fire Safe Standards Rev $118.98 Total Charged: $1,130.56 Fees Paid: $1,130.56 DBSMIP Residential $8'78 Balance Due: $0.00 Receipt No: B8651 LICENSED CONTRACTOR'S DECLARATION OWNER / BUILDER DECLARATION Contractor (Name) State Contractors License No. / Class / Expires I HEREBY AFFIRM UNDER PENALTY OF PERJURY that I am exempt from the Contractor's License FREEDOM HOMES 839031 / B / 5/31/2010 Law for the following reason (Sec. 7031.5), Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair any structure prior to its issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed I HEREBY AFFIRM UNDER PE LTY OF PERJURY that I am licensed under provisions of Chapter 9 (commencing with S ion 7000) ivision 3 of the Business and Professions Code, and my license pursuant to the provisions of the Contractor's License Law [Chapter 9 (commencing with Section 7000) is full force and effec . of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects /22/2008 the applicant to a civil penalty of not more than five hundred dollars ($500); Please check one of the following: Contractors Silnture Date ❑ I, AS OWNER OF THE PROPERTY, OR MY EMPLOYEES WITH WAGES AS THEIR SOLE COMPENSATION, WILL DO THE WORK, AND THE STRUCTURE IS NOT INTENDED OR OFFERED FOR SALE (Sec. 7044, Business and Professions Code: The Contractors License Law does not apply to an owner of the property, who builds or improves thereon, and who does WORKERS' COMPENSATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY one of the following declarations: HAVE the work himself or herself or through his or her own employees, provided that such improvements ❑I AND WILL MAINTAIN A CERTIFICATE OF CONSENT TO SELF -INSURE FOR are not intended or offered for sale. If, however, the building or improvement is sold within one WORKERS' COMPENSATION, as provided for by Section 3700 of the Labor Code, for the year of completion, the owner -builder will have the burden of proof that he or she did not build or rfo peance of the work for which this permit is issued. improve for the purpose of sale.). AVE AND WILL MAINTAIN WORKER'S COMPENSATION INSURANCE, as required by ❑ I, AS OWNER OF THE PROPERTY, AM EXCLUSIVELY CONTRACTING WITH LICENSED CONTRACTORS TO CONSTRUCT THE PROJECT (Sec. 7044, Business and Professions Code: Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. The Contractors License Law dows not apply to an owner of the property who builds or improves My Workers' Compensation insurance carrier and policy number are; thereon, and who contracts for the projects with a contractor(s) licensed pursuant to the Carrier: XL Specialty Insuranpolicy Number:RWD9435192 Exp. Date:?/1/2009 Contractors License Law.). (This section need not be competed if the permit is or once uniteliars ($100) or es— s ) IAM EXEMPT under Section B. & P.C. for this reason: ❑ I CERTIFY THAT IN THE PERFORMANCE OF THE WORK FOR WHICH THIS PERMIT IS ❑ ISSUED, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California, and agree that if I should become subject to the workers' X 9/22/2008 compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those Owners Signature Date provisions. 9/22/2008 I hereby certify that I have read this application and state that the above information is correct. I agree to comply with all City and County ordinances, rules, regulations, and State laws relating to building Signature Date WARNING: FAIL RE TO SECURE WORKERS' COMPENSATION COVERAGE IS UNLAWFUL, construction, and with any and all conditions of permit. I agree to defend, indemnify, and hold harmless Butte County, its officers, agents and employees from any and all claims and liability for personal AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, injury, including death, and property damage caused by, arising out of, or in any way connected with the issuance of this permit. I hereby acknowledge that issuance of this permit does not authorize the DAMAGES AS PROVIDED FOR INSECTION 3706 OF THE LABOR CODE, INTEREST AND use or occupancy of any sidewalk, street, or subsidewalk. I hereby authorize representatives of Butte ATTORNEY'S FEES. County to enter the above m tioned pro y for inspection purposes. I hereby certify that I am the P rtyowner oramauthorizA ctonth ropertyownersbehalf. 9/22/2008 CONSTRUCTION LENDING AGENCY 1 HEREBY AFFIRM UNDER PENALTY OF PERJURY that there is a construction lending agency for Name of Permi S N] Date the performance of the work for which this permit is issued. (3097 civ. code) Owner Contractor OR. Agent for Owner ❑Agent for Contractor FILE COPY Lenders Address City State Zip BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION" OFFICE #: (530) 538-7541 FAX #: (530) 538-2140 A FEE WILL BE REQUIRED AT TIME OF APPLICA TION Website: www.buttecounty.net/dds PLEASE PRINT CLEARLY -�� • �s �q PERMIT , 4 NO. t BIN # "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public infurimitiun related to this application is subject to public inspection and will be posted on the County's website for electronic access. CONTRACTOR OWNER INFORMATION Last Name Mailing Address First Name 0 C>D City ®� Zip �b �/b State C Zip Phone �O � Fax , E-mail Fax CONTRACTOR Name h v 1 Address , _2 E� 639 / City e movi � �- State 04 Zip �b �/b Phone to Fax o E-mail Lic. # kl o 3 ! Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name City o %L� Address Zip City Fax �� State Zip Phone Fax E-mail Open Cc State License Number APPLICANT INFORMATION Name JzF_t>0 , ' h 'mss `/.r5. 'Address g �y � : y,� Ez K/ �1 ��l City o %L� State �i �,j Zip PhoneQ. Fax �� E-mail PROJECT LOCATION Property Address - City WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than licensed contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Address DESCRIPTION OR SCOPE OF WORK: i Sq FT- Living �o Garage Open Cc ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): i I For office use Zoning Occ. Zone I I SRA Yes I Na I Type Const. dI WA F BUTTE COUNTY FEE SUMMARY 7 County Center Drive Oroville, CA 95965 Department of Development Services Phone (530) 538-7541 Fax (530) 538-2140 Permit Number: B08-1814 Job Address: 3540 STONE MOUNTAIN RD Contractor: FREEDOM HOMES 2243 FEATHER RIVER BLVD OROVILLE, CA 95965 Printed: 9/4/2008 11:17 am Fee Description Account Number Fee Amount Paid Date Pmt Amt DBEH Building Review Fee 0021-540013-4614901-1010( $78.90 9/4/2008 $78.90 DBFIRE Fire Inspection (SRA) 0100-450001-4617240-1010( $107.00 9/4/2008 $107.00 0100-450001-4617240-1010( $107.00 DBOMSC Fire Safe Standards Rev 0010-440001-4210501-1010( $118.98 DBFIRE SRA Fire Plan Review (S 0100-450001-4617240-1010( $107.00 9/4/2008 $107.00 DBMSC Mobile Home Permit Fee. 0010-440001-4210500-1010( $361.74 DBF MH Plan Check 0010-440001-4210501-1010( $241.16 9/4/2008 $241.16 DBSMIP Residential 1001-0-280-1011298 $8.78 Printed By: Gwyn Benedict 19130.56 $534.06 Balance Due: $596.50 At the time of permit application, I was advised the above fees are required prior to issuance of the permit. process. Date: 9/4/2008 Pursuant "overnment code Section 66020, you are hereby notified those items listed above may have been imposed on your project. You have 90 days from the date of approval of the project or from the impostion of the above referenced items during which you may request a protest. The requirments for a protest are specified in Government Code Section 66020(a). Butte County Department of Public Works J. MICHAEL CRUMP, DIRECTOR LAND DEVELOPMENT DIVISION Storm Water Managment Program 7 County Center Drive Oroville, CA 95965 (530) 538-7266 Telephone (530) 538-7171 Fax www.buttecounty.net/dds National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgment [LESS THAN 1 ACRE 1 Reference Number: B08-1814 Date: 9/4/2008 Location: 3540 STONE MOUNTAIN RD By: GLB Parcel Number: 058-440-008 Sub Type: SFD-Mobile Home PI Owner Name: BAKER, ROBERT Phone: (530) 210-8582 Description: NEW MH EX SITE PERM FND 1350'- HUMBOLDT FIRE By signing below, I the project owner/owners' agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site buildouts of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the state of California Regional Water Quality Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for this project that disturbes one acre or more of land may result in revocation of grading and/or other permits or other santions provided by law. Signed; Title: FILE Date: 9/4/2008 Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds "PERMIT APPLICATION DATA SHEET" Reference Number: B08-1814 Date: 9/4/2008 Location: 3540 STONE MOUNTAIN RD By: GLB Parcel Number: 058-440-008 Sub Type: SFD-Mobile Home PI Owner Name: BAKER, ROBERT Phone: (530) 210-8582 Description: NEW MH EX SITE PERM FND 1350'- HUMBOLDT FIRE ❑ Marysville School District, 1919 B Street, Marysville CA 95901 - (530) 741-6000 The above permit application has the following Clearances required prior to permit issuance. Please contact each department indicated below regarding specific requirements pertaining to your permit application. Yes No SEWER DISTRICTS ❑ ❑ Thermalito Irrigation District, 410 Grand Avenue, Oroville CA 95965 - (530) 533-0740 ❑ ❑ LOAPUD, 1960 Elgin Street, Oroville CA 95966 - (530) 533-2000 ❑ ❑ City of Chico, PO Box 3420, 411 Main Street, Chico CA 95927 - (530) 879-6700 PARKS & RECREATION DISTRICTS ❑ ❑ Chico Area Recreation District, 545 Vallombrosa, Chico CA 95926 - (530) 895-4711 ❑ ❑ Durham Park & Recreation District, 9447 Midway, Durham CA 95938 - (530) 345-1921 ❑ ❑ Feather River Recreaction & Park District, 1200 Myers Street, Oroville CA 95966 - (530) 533-2011 0/ ❑ Paradise Parks & Recreation, 6626 Skyway, Paradise CA 95969 - (530) 872-6393 SCHOOL DISTRICTS ❑ ❑ Biggs Unified School District, 300 B Street, Biggs CA 95917 - (530) 868-1281 ❑ ❑ Chico Unified School District, 1163 East 7th Street, Chico CA 95926 - (530) 891-3006 ❑ ❑ Durham Unified School District, 4920 Putney Drive, Durham CA 95938 - (530) 895-4675 ❑ ❑ Gridley School District, 429 Magnolia, Gridley CA 95948 - (530) 846-4723 ❑ ❑ Marysville School District, 1919 B Street, Marysville CA 95901 - (530) 741-6000 ❑ ❑ Oroville Elementary School District, 2795 Yard Street, Oroville CA 95966 - (530) 532-3000 [FkK ❑ Oroville Union High, 2211 Washington Ave, Oroville CA 95966 - (530) 538-2300 Ext:105 ❑ ❑ Paradise Unified School District, 6696 Clark Road, Paradise CA 95969 - (530) 872-6400 OTHER ❑ ❑ Recorded copy of Agricultural Acknowledgment Statement- See Attached Instructions ❑ ❑ City of Biggs Planning Department, 3016 Sixth Street Biggs CA 95917 - (530) 868-5447 0� F] Other: I T `� C) a v'T71Tto— —f(:, �1 ❑ ❑ Other: "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Signature of Applicant: Date: 9/4/2008 FILE California Department of Forestry and Fire Protection Butte County Fire Department Fire Prevention Bureau 176 Nelson Avenue, Oroville CA 95965 (530) 538-7888 Office, (530) 538-2105 Fax Reference Number: B08-1814 Date: 9/4/2008 Location: 3540 STONE MOUNTAIN RD By: GLB Parcel Number: 058-440-008 Sub Type: SFD-Mobile Home PI Owner Name: BAKER, ROBERT Phone: (530) 210-8582 Description: NEW MH EX SITE PERM FND 1350'- HUMBOLDT FIRE To meet the requirements of Government Code section 51182 and Public Resource Code 4291, Butte County requires a pre -construction inspection to pro -actively provide the below building and site requirements to the property owner. Your property is located within the State Responsibility Area (SRA) of Butte County. All development within the SRA is required to meet the below requirements: ✓ Public Resources Code 4290 ✓ Public Resources Code 4291 ✓ California Building Code, Chapter 7A ✓ Butte County Improvement Standards Requirements prior to scheduling the pre -inspection: ✓ Full plan submittal to Butte County Development Services -Building Division ✓ Driveway and building pad must be identified on site ✓ Structure location must be staked out on the building site Requests for inspections shall be made a minimum of 72 hours in advance by calling the Fire Prevention Bureau's 24 hour inspection line at (530) 538-6226, (When the recording comes on, enter the extension number). For the pre -inspections, the property owner or authorized agent is required to meet the inspector at the construction site with two hard copies of the site plan. I have read and understand the above pre -inspection requirements 9/4/2008 Date Rev'd 5/7/07 ignature All of the Fire Safe Requirements are posted on the Butte County Fire Department website at http://buttefire.org/Fireprevention/protplan/proti)lan.html FILE Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-2140 Fax www.buttecounty.net/dds NOTICE TO BUILDERS** Before your building permit can be issued, your plans must be checked for compliance with the California Building Codes. In addition, your plans are routed to other regulatory entities including but not limited to Planning, Public Works, Environmental Health, and the California Department of Forestry for their clearances and approvals. There are some things you can do to expedite your permit: 0 Make sure your application is complete. 0 Be responsive to requests from County departments for any additional materials or requirements. The Building Division places its highest priority on processing building permits as quickly as possible and each day that passes without a complete application adds to processing time. Every permit issued by the Building Official shall expire and become null and void if the work authorized by such permit is not started or completed within one year from the date of issuance of such permit. A permit may be renewed (for a fee) prior to expiration an indefinite number of times, provided construction progress has been documented by the Building Division during each year during scheduled inspections. No changes may be made in the original plans and specifications for such work. In order to reinstate action on a permit after expiration, the permittee shall pay a new full permit fee and additional plan checking and documentation may be required. Upon completion of work covered by this permit, please contact this office for final inspection. As a reminder to you, it is illegal to occupy this building or any portion of the building for which this permit is issued without a final inspection. EXPIRATION OF PERMIT APPLICATION AND REFUND POLICY" Application for which a permit has not been issued will expire one year after date of application. Refunds may only be made upon written request by the person who originally paid the fees. Refunds for permit applications, if the permit has not issued, but not after 180 days from the date of fee payment. Fees paid at the time of application are for Plan Check and administration. The Plan Check portion of fees is refundable only if the permit is cancelled or withdrawn before any plan checking is done. Building Division costs will be deducted prior to authorizing a refund and a charge to process the refund application will be assessed. Refunds on permits (issued) may be requested prior to the expiration of the permit, provided no work has been done pursuant to the permit. An Inspection may be required (and deducted from any refund amount) to determine no work was done. Fee/refund information can be read on-line at http://municipalcodes.lexisnexis.com/codes/butteco/ "When filed, this application and all supporting material becomes subject to the California Public Records Act. All public information related to this application is subject to public inspection and will be posted on the County's website for electronic access. Reference Number: B08-1814 Location: 3540 STONE MOUNTAIN RD Parcel Number: 058-440-008 Date: 9/4/2008 Owner Name: BAKER, ROBERT Phone: (530) 210-8582 Description: NEW MH EX SITE PERM FND 1350'- HUMBOLDT FIRE Signature of Applicant: Date: 9/4/2008 FILE PERMIT CHECKLIST FOR BUTTE FIRE STORM 2008 Permit Fee Waiver/Reduction Application Form (this form must be reviewed by Supervisor) completed or attached to Damage Assessment Case ('Completed Application —1511 documents required for submittal ELP�ans reviewed by Plan Checker C- For fee waivers – checked size and use of structure to building and assessor's more info screens on Damage Assessment Case for the parcel W�d review for EH Haz-Mat write `Butte Fire Storm 2008' in "Notes" ge return date on all reviews for 10 days from application date ❑ Application given to Supervisor Reviewed by; Date: 9/x"/0, CADocuments and Settings\amefford\My Documents\Trak It\Permit Procedures for Trakit\PERMIT CHECKLIST FIRE STORM 2008.doc Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile www.buttecounty.net/dds PLAN CHANGE E�/ Owner's Name: 30_� BP#: Date: Contact Person & Phone Number: RECHECK ❑ AP#: br)U - AZ40 ` w Received By: Time: OSE OF PLAN CHANGE OR RECHECK ❑ Response to Inspector's Correction Notice — Inspector's Name: ❑ Response to Plan Check Letter — Plans Examiner's Name: *Submit two (2) drawings reflecting the revision for plan review along with your approved plans. If engineering is involved in this revision, the engineer must put his requirements on these drawings and wet stamp and sign two sets of engineered drawings. Drawings must clearly show changes proposed and locations involved. WHEN APPROVED: Mail to Call Deliver with Next Inspection ( for 8 V2 X 11 only) and hold for pick-up. Minimum revised plan check fee to be collected at time of submission of revision, plans examiner will determine if additional plan checkinj fees are needed: ❑ Minimum $118.98 paid. /IA - ❑ Additional Fee Amount: Receipt #: Revised 2/08 HOUSING ACFNCY 1 DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT Amg1d C hum DIVISION OF CODES AND STANDARDS ' 1800 Third Street, Room, 260, P.O. Bax 1407 Saaamento,CA 95812-1407 From TDD Phones 1(800) 735-2929 (916) 445-9471 FAX (916) 3274712 www haLcagov w September 1, 2008 NOTICE OF EMERGENCY ACTION SUBJECT: MANUFACTURED HOME, MOBILEHOME, MULTIFAMILY MANUFACTURED HOME AND COMMERCIAL MODULAR IGNITION RESISTANT CONSTRUCTION SYSTEM REGULATIONS The Department of Housing and Community Development's (HCD) proposed emergency regulations that affect the exterior design, construction, installation and alteration of any new or used manufactured home, multifamily manufactured home or commercial modular or used mobilehome designated for installation in Wildland Urban Interface Fire Areas in California has been approved by the Office of Administrative Law (OAL) and is effective beginning September 1, 2008. The emergency regulations are adopted into California Code of Regulations, Title 25, Chapter 3, Subchapter 2, and adopt by reference portions of the California Code of Regulations, Title 24, California Building Code, Part 2, Chapter 7A. The emergency regulations have been filed with the Secretary of State, making the emergency regulations effective for one hundred and eighty (180) days. Within this 180 -day effective period of September 1, 2008 through February 27, 2009, HCD is proceeding with a regular rulemaking action, including a public comment period. The emergency regulations will remain in effect during this rulemaking action. You may review the new regulatory language on HCD's website at the following address: http://www.hcd.ca.gov/codes/mhp/ under the heading Wildland Urban Interface (WUI) Emergency Regulations. If you have any questions regarding this proposed emergency action please contact Richard Weinert at (916) 445-3338. REFER TO CALIFORNIA TITLE 25 - SEcriO1i1337- SKIRTING SHALL NOT ii BE INSTALLED UNTIL ALL UNDERFLOOR INSPECTIONS HAVE BEEN APPROVED FOR MANUFACTURED HOME tsutte uounry uepartment of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 - (530) 538-7601 Telephone ! 1 (530) 538-7785 Facsimile RSR i ^� www.buttecounty.net/dds ju e www.buttecieneralplan.n.et.. �`,, e���0 ADMINISTRATIONBUILDING * PLANNING Skirting for Manufactured/Mobile Homes in a State Responsibility Area 20D7 '74 Notes: 1. These are acceptable options where there is no perimeter masonry foundation. 2. Siding must -be supported a minimum of 6" above finish grade, except when concrete slab (option' 3) is used. 3. Siding must be a product approved by the California State Fire Marshall and installed according to the manufacturers listing. Approved products may be viewed at: .http://www.osfm.flre.ca.gov/strucfireengin eer/odf/bml/wuioroducts.pdf CIPT low OPTM +.MOSILEHOME. JI�PpRo./E� MOBILEHOME A p R izp�/F.D 51 P I h1� 51DINlj. - �p.tJN �L orz IIx �il W Fib W oo b PL a1'r- I gnH KH , ¢' L,JIDE. MItJ I -0 N14 I o Prr2aVEt; hl al Na. .7 s r14L,0 _. R£t�V•10o1� 0l2 `. �` a Go Al I IIJtJcuS GO NGf2E"f�21,c Z x 11i 1 F14 Df`) GRADE AWAY FROM MOBILEHOME TO A DISTANCE OF 5'-0" MIN. (TYPICAL FOR.ALL OPTIONS) �i In LOF�ctzal-15 46 ,.w Intl Mlhl. MOBILEHOME . C}IAIJN�L ole 21cA0 r bl= oP_ .. 114 J(fj S. S. ,� 11 CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL WILD LAND URBAN INTERFACE (WUI) PRODUCTS Published by CAL -FIRE FIRE ENGINEERING DIVISION Revised 08/15/08 htto•//osfm fire ca_.gov/s trucf] re e ngi nee r/pd f/bm I /WLI I products.pdf Starting January 2008, the new 2007 California Building Code (CBC) becomes effective. For products to be used in the Wildland Urban Interface (WUI), there are some regulations that required building products to comply with specific standards. In an effort to provide the home owners, Industries, designers, local fire and building officials a readily list of "compliance WUI products", the State Fire Marshal Is publishing this "WUI Products Handbook". All products published In this handbook have been reviewed and verified their compliance In accordance with the new 2007 CBC by SFM staff. Only products submitted to the SFM and in compliance will be published. It should be noted that products are not in this handbook may still comply with the standards. It is not a requirement for any products to be In this handbook. This handbook will be categorized Into 4 main sections: 1. Exterior Wall Siding and Sheathing (SFM Standard 12-7A-1) 2. Exterior Windows (SFM Standard 12.7A-2) 3. Under Eave (SFM Standard 12.7A-3) 4. Decking (SFM Standard 12-7A-4) The handbook may contain other products that are not listed above. The SFM reserves the right to remove any products In this handbook for cause. The local Authority Having Jurisdiction (AH)) has the right to approved or dis- approved products for used within their respective Jurisdiction. Our approvals are based upon technical data submitted by applicants. The CSFM Fire Engineering staff reviews test results and/or other data, but does not make an independent verification of any claims. All products shall be constructed in accordance with all applicable codes and ordinances. Refer to the appropriate AH) for details. Building Standards and Materials for Building Code Chapter 7A, 2007 California Building Code The California Building Commission adopted the Wildland-Urban Interface (WUI) codes in late 2005. The majority of the new requirements take effect in 2008. These new codes include provisions for ignition resistant construction standards in the wildland urban interface. The updated fire hazard severity zones will be used by building officials to determine appropriate construction materials for new buildings in the wildland urban interface. The updated zones will also be used by property owners to comply with natural hazards disclosure requirements at time of property sale. It is likely that the fire hazard severity zones will be used by local government as they update the safety element of general plans. The new building standard for the Fire Hazard Severity Zones will be enforced by the Building Official as projects go through the plan checking process. To best assist them in determining If a product meets the code requirements, the State Fire Marshal's Building Materials Listing program (BML) Program is accepting applications for materials for listing or for the review of meeting the standards. These materials will be posted on the SFM BML website at: http•//osfmfireca v/ ticf!Eeengineer/pdf/bml/wuip o u tts. df and the Wildland Urban Interface Building Codes page of the Wildland Hazards and Building Codes at: htt /www.fire.ca,gov ire preventionMre prevention wttdlitnd codes pltp The SFM listing service provides building authorities, architectural and engineering communities, contractors, and the fire service with a reliable and readily available source of information. Since the materials under Wildland Urban Interface Building Codes (except roof wood shakes and shingles) are not required by law to be listed by the SFM, the listings for these products are strictly voluntary. Materials not listed by the SFM may still qualify for use provided they met all the requirements under Chapter 7A. If not listed on the SFM site, all documentation and testing certificates showing compliance must be submitted to the building official having jurisdiction for final approval. For product listing Information please contact: 'Ben Ho, Chief Fire Engineering Division 1131 S Street, Sacramento, CA 95811 (916) 445- 8312 ben.honfire.ca.gov Information regarding the listing application, regulations and publications etc. can be downloaded at: http://osfm.fire.ca.gov/strucfireenAineer/sirucflreengineer bml.php http•//osfm fire ca aov/strucfireenaineer/pdf/bmlAistmaApplication.pdf http//osfm fire ca aov/strvcfreengineer/odf/bml/t-19.0 http//osfm fire ca aov/strucfireenaineer/pdf/bml/categorvbm.pdf h_p l/osfm.fire.ca.gov/­strucfireen ineer/pdf/lab/approvedtestin_qlabspdf For questions relative to Wildland Hazards and Wildland Urban Interface_reaulations and Chapter 7A please contact: Ethan Foote, Assistant Chief WUI Regulations Unit 1131 S Street, Sacramento, CA 958111 (916)445-8200 ethan.foote0fire.ca.gov Information regarding all Wildland Urban Interface issues can be downloaded at: http:t/www.fire.ca.gov/tire_prevention/fire_prevenUon wildland_codes.php All SFM W standards can be downloaded at the following links: Testing Standards CA SFM 12.7A-1, Exterior Wall Siding and Sheathing http:/MvAv.fire.ca.goviriire—prevenUonidownloads/Part_iLCA_SFM 12-7A-t_Test_Standards.pdf Y Testing Standards CA SFM 12.7A-1, Exterior Windows hitp:/Mrww.fire.ca.govlfire—prevenlion/dovmloadsrPart_12_CA_SFM_12.7A-2 Test_Standards.pdf Y Testing Standards CA SFM 12.7A-1, Under Eaves hop:ilvlww.f ire.ca.gov/Rre prevention/downloadsiPart_12_CA_S FM_12-7A-3_TesLStandards. pdf L Testing Standards CA SFM 12.7A-1, Decking hOp:lMiww.fire.ca.govifire—preventlonldownloads/Parl_72_CA_SFM 12-7A-0 TesLSlandards.pdf 2007 California Building Code CHAPTER 7A MATERIALS AND CONSTRUCTION METHODS FOR EXTERIOR WILDFIRE EXPOSURE(SFM] SECTION 701A SCOPE, PURPOSEAND APPLICATION 701A.1 Scope. This chapter applies to building m8mdals, systems and or assemblies used In the exterior design and construction of new buildings located within a lMldlend-Urban Interface Fire Area as defined In Section 702A 701A.2 Purpose. The purpose of this Chapter Is to establish minimum standards for the protection oflife and property by increasing the ability of a building located In any Fire Hazard Severity Zone wohin Slate Responsibility Areas or any Midland -urban Interface Fire Area to malst the intrusion of flame or burning embers projected by a vegetation fire and conmbufes to a systematic reduction In conflagration losses. 70/A.3. Application. New buildings located In any Fire Hazard Severity Zone within State Responsibility Areas or any Midland -Urban Interface Fire Area designated by the enfoming agency lar which an application for a building permit Is 'submitted on or after December 1, 2005, shall comply with the following Sections: 1. 704A.1— Roofing 2. 704A.2 —AHIc Ventilation 701A.3.1 Alternates formaterlals, design, tests, endmothods ofconstrrctlon. The enforcing agencyls permlttedto modilythe provisions of this chapter Por site-spedfie conditions In accordance with Appendix Chapter 1, Section 104.10. When requlrod by the enforcing agencylorthe purposes ofgranting modifications, a fni preloction plan shallbe submitted In accordance with the California Fire Code, Chapter 47. 701A.3.2 New Buildings Locatedin Any Fire Hazard Severity Zone. Newbufldings located In any Fire Hazard Severity Zone shall comply with one of the following: 1. State Responsibility Areas. New buildings located In any Fire Hazard Severity Zone within State Responsibility Areas, lar which an application lar a building permit Is submitted on or ager January 1, 2000, shall comply with ail sections of this chapter. 2. Local Agency Very -High Fire Hazard Severity Zone. New buildings located M oily Local Agency Very -High Fire Hazard Severity Zone for which an application for a building permit Is submitted on or ager July 1, 2008, shall comply with all sections of(his chapter. 3. Wildland-Urban interface Fire Area designated by the enforcing agency. New buildings located In any Midland -Urban Interface Fire Area designated by the enforcing agency for which an application for a building permit Is submitted on or after January 1, 2008, shell comply with all sections of (his chapter. 701A.3.2.11nspeclion and certification. BulMing permit applications and final completion approvals forbuild/ngs Wlhln the scope and appticaflah of this chapter shall comply with the following: , 701A.3.2.2 The local building official shoo, prior to construction, provide Ne ownerorapplicant a ceNficaeon that the building as proposed to be built complies with fig applicable state and local bu(IrMg standards, Inducting those for materials and construction methods for %W&e exposure as described In this Chapter. 701A.3.2.3 The local building official shag upon completion ofconsbudion, provide Ne owrierorappgoant with a copy ofthe Mal Inspection report that demonstrates the building was consbuotedin compliance with ell applicable slide and l calbuilding standards, Including those for materials and construction methods for wildfire exposure as described In this Chapter. 701A3.2.4 Prforto buflding per iff Mal appovat the prepefty shallbe In compliance wahahe vegeletlon dearanceregiaements prescribetI M CagAxnia Pubk Resources Code 4291 and Cafiforrnla Government Code Section 51182 SECT70N 702A - DEFINITIONS For the purposes of Nis chapter, certain terns are defined below: CDF DIRECTOR means the Director ofthe California Department of Forestry and Fire Protection. FIRE PROTECTION PLAN Is a document prepared We specifib project or development proposed fore Midland -Urban Interface Fire Area. It describes ways to minlmize and mitigate potential for loss from wildfire exposure. The Fire protection Plan shag be In accordance wilh this chapter and the California Fire Code, Chapter 47. When required by the enforcing agency tar the purposes of granting modifications, a gra protection plan shag be submitted. Only locally adopted ordinances (hat have been Red wlfh the California Building Standards Commission orthe Department of Housing and Community Development In accordance with Section 10 1. 8 shall apply. FIRE HAZARD SEVERITY ZONES are geographical areas designated pursuant to California Public Resources Codes Sections 4201 through 4204 and classified as Very High, High, or Moderate in State Responsibility Areas or as Local Agency Very High Fire Hazard Severity Zones designated pursuant to California Government Code` Sections 51175 through 51189. See California Fire Code Article 86, The California Code of Regulations, Title 14, Section 1280 entitles the maps ofthese geographical areas as'Maps ofthe Fire Hazard Severity Zones In the State Responsibility Area of Cagfomla.' IGNITION -RESISTANT MATERIAL la anypmdud wi)dh, when tested In accordance wMASTM E84 Ara periodof30minutes. shal haw a game spread dnof over 25 grid show no evidence ofpogress" combustion. In addition, the game font shag not pogessmcre am 1035 feet p2Wai) beyond the cargo** algia burner at any time during the test. Materials shag pass the accelerated weathering test and be identified as Exterior type, In accordance with ASTM D2898 and ASTM D3201. Ali materials shag bear Identtflcadon showing the &a performance rating thereof. That Mengfication shall be Issued by ICC-ESACBO ES or a testing facility recognized by the State Fire Marshal having a service for Inspection of materials of the factory. Fire-Refanlant-Tmated Wbodornoncombusfible motorists as dehred 61 se Wan 202 shagsatisyme intent of fins section. The enforcing agencymay use otherdefiriflons oflgnNlon•redstam materialthatrefiect wildfire exposure to buiding materials andNr theirmaterials performance in resisting ignition. LOCAL AGENCY VERY HIGH FIRE HAZARD SEVERITYZONEmeens an area designated by a local agency upon the recommendation ofthe COO Dlrectorpursuant fo Govemment Code Sections 51177(c), 51178 and 5118 that Is not a state responsibility area and where a local agency, city, county, city and county, or district Is responsible nor fire protection. STATE RESPONSIBILITYAREA means lands (hat are classified by the Board ofForesby pursuant to Public Resources Code Section 4125 where the finandalmsponsibillfy olpreventing and suppressing forest fuss Is priman7ythe responsibility ofthe state. WILDFIRE Is any uncontrolled fire spreading through vegetative reels that threatens to destroy life, property, wmsoumes as defined In Public Resources Code Sections 4103 and 4104. WILDFIRE EXPOSUREls one or a combination ofredlent heat. convective heat, dbad game contact and burning embers being projected by vegetation fire to a structure and Its Immediate environment. ML GLAND -URBAN INTERFACE RRE AREA Is a geographical me klentifled by the state as a 'Fire Hazard Severity Zone'In accordance with the Public Resources Code Sections 4201 through 4204 and Government Code Sections 51175 through 51189, or other areas designated by the enforcing agency to be at a significant risk tram wildfires. See Section 706A for the applicable referenced Sections of (he Government Code and the Public Resources Code. SECTION 703A— STANDARDS OF QUALITY 703A1 General. Materia{ systems, and methods olconstructlon used shall be In accordance with this Chapter. 703A.2 Qualification by Testing. Material and material assemblies tested In acconfanco with the requirements of section 7034 shallbe acceptedtoruse when the results andconditions offhose tests are met. Testing shall be parfomredby a testing agency approved by the State Fire Marshal orklenfited by an ICC-ESICBO£S report 703A.3 Standards of Quality. The State Fire Marshal standards gstedbelow and as referenced In this Chapter are located In the California Referenced Standards Code, Pan 12 and Chapter 35 of this code. SFM 12.7A-/, Exterior Wag Siding and Sheathing SFM 12.7A-2, Exterior Window SFM 12.7A-3, Under Eave SFM 12.7A4, Decking SECTION - 704A - MATERIALS, SYSTEMS AND METHODS OF CONSTRUCTION SECTION 704A 1- ROOFS 704A.1 ROOFING 704A.1.1Oaneral. Roofs shag comply with the requirements of Chapter 7A and Chapter lS Roots shag have a roofing assembly Installed in accordance with tis listing and the manufacturers Installation Instructions. 704A. 1.2 Roof Coverings. Where the MI'Prefile allows a space between the rootcovering andmoldecking, the spaces shag be constructed to prevent the Intrusion of flames and embers, be fire -stopped with approved materials Or have one layer of No. 72 ASTM cap sheet Installed over the combustible decking. 744A.1.3 Roof Valleys. When provided, valley flashings shall be notless than 0.019- inch (0.48 mm) (No. 26 galvanized sheet gage) conoslon-resistant metal installed over a mlplmum 36 Inches (9 14 mm) wide underleymenf consisting o/one layer of No. 72 ASTM cap sheet running the full length of the va0ey. 704A.1.5 Roof Gutters. Roofguhers shagbe provided with the means to praventlhe accumulation olleaves anddehds In the gutter. 704A.2 Attic Ventilation. 704A.2.1 General. When required by Chapter 15, mol and attic vents shaflreslstthe intrusion of flame end embers Into the attic area of the structure, or shag be protected by corrosion resistant non-combustible wire mesh with 34 Inch (6 mm) openings or Its equivalent 704A.2.2 Eave or COmlce Vents. Vents shag not be Installed in eaves and cortices. Exception: Eave and comics, vents maybe used provided they resist the Intrusion of flame and burning embers Into the attic area o/the structure. 704A.2.3 Eave Protection. Eaves and sothfs shall meet the requirements of SFM 12.7A-3 or shag bs protected by Ignlflon- resistant materials ornoncombustible construction on the exposed underside. 704A.3. EXTERIOR WALLS 704A.3.1 Gen mL Exterior wags shah be epproved noncombustible orlgnlgon resistant material, heavy timber, Orbit Wall construction or shall provide protection from the 0>dusbn offlames and embers irn accordance with standadSFM 12.7A-1. 704A.3.1.1 Exterior wall coverings. Exterior wad coverings shall extend from the top or the foundation to (he real, and terminate at 21nch (50.8 mm) nominal solid wood blooming between mItem at ell roof overhangs, Orin the case of enclosed eaves, terminate at the endosum. 704A.3.2 Exterior Wall Openings. Exterior wag openings shag be in accordance Win Ws section. 104A.3.2.1 Exterior Wall Vents. Unless otherwise prohibited by other provisions ofthls code, vent openings in exterior waits shall resist the Intrusion of flame and embers lob the structure or vents shall be screened with a cormslon+eslsfant non- combustible wire mesh with h bw h (8 mm) openings or Is equivalent 704A3.2.2 Exterior Glazing and window walI5. Exterior windows, window wags, glazed doors, and glazed openings within exterior doors shag be insulating -glass units wgh a minimum or one tempered pane, or glass block units, or have a two resistance rating of not less than 20 minutes, when tested acoordmg to ASTM E 2010, or conform to the performance requbaments of SFM 12.7A-2 704A.3.2.3 Exterior doorassemblles. ExtedardoOf 8ssambhles shallcnnfonn M Me performance requirements ofstandard SFM 12.7A -for shallbe ofapprovednoncombustible conshudlon, or solid core woodhaving shies andrells not less then 116 k hes thick with Interior geld panel tfddohess no less than 1 1/4'Odrk or shag have a Are resistance rating of not less than 20 minutes when tested according to ASTME 2074. Exception: Noncombustible or exterior gra retadent treated wood vehicle access doors are notrequietl to comply W M this chaptar. 70444 DECKING, FLOORS AND UNDERFLOOR PROTECTION 70444.1 Decklpg. 70444.1.1 Decking Surfaces. Decklpg surface; stalrtreads, risers, andlandi gs oldeck; parches, S balconies where any portion of such surface Is witidn 10 feet (3048 mm) o/the Primary structure shah comply with one of the following methods: 1. Shallbe constructed of Igndlon Resistant Materials and pass the performance mqubements of SFM 12-7A-4, Parts A and B. 2 Shag be constructed wm heavy 6,711W. exterlarfve retardant treated wood orapproved non-combustible materials. 3.Shall pass the performance requirements or SFM 12.7A4, Pan A, 12-7A-4.7.5.1 any vdh a nel peak heat reteese rare of 25kWAg4lora 40mhute observation period and* a Decking surface material shag pass the accelerated weathering fest and be Identified as Exterior type, in accordance with ASTM D2898 and ASTM D3201 end; b. The eldedorWww "to %tk h&Me dedclsefladhedandvb* 10 (3048mm) feet ofthe deck shaftbe constructed of approved noncombustible or Ignition resistant material Exception: Wags are net requited to comply with this sub-sedhn Il the decking surface material conforms to ASTM E.84 Class B flame spread. The use or paid; coatings, stains, orother surface treatments are not an approved method ofprotedion as required in this Chapter 70444.2 Underfloorand Appendages Protection 704A4.2.1 Underside o/Appendages and Floor projections. The underside ofcenidevered andoverhangbg appendages and floor projections shag maintain the Ignidon+edstant Integrity of extedar wags, orthe projection shall be enclosed to the grade. 704A.4.2. Unenclosed UndernoorProtectlon. Buildings shallhave agunder0oormasarcbsedtomegrodev&texferkuwass in accords= with section 704AI Exception: The complete endosum ofundernearames may be omitted where the underside Olaf/ exposed doors, exposed smrduml columns, beams and supporting wags ata protected es required with exterfor/gMlon mslstantmaterfal cons(rodion tube heavy timber. " 705A. ANCILLARY BUILDINGS AND STRUCTURES 705A.1 Ancillary Buildings and Structures. When required by the enforcing agency ancillary bdldings and smrdhrres and detached accessory structures shag comply with the provisions of this Chapter. 8 Wildland Urban Interface (WUI) Products Exterior Wall Siding and Sheathing (SFM Standard 12-7A-1) *Company Name: APA -THE ENGINEERED WOOD ASSOCIATION 7011 South 1911 Street, Tacoma, WA 98466 Product Description: "APA 30310" plywood siding with shiplap edges, nominal 19/32" thick and grooves spaced 4" on center, manufactured with veneers of all Southern Pine or Douglas Fir face, back and center with Hemlock or Douglas fir cross piles, 4'x8' panel. *Company Name: APA -THE ENGINEERED WOOD ASSOCIATION 7011 South 191" Street, Tacoma, WA 98466 Product Description: "APA 3030" plywood siding with reverse -board and batten, nominal 19/32" thick and shiplap edges, grooves spaced 12" on center, manufactured with face, back and center of Douglas Fir veneers and cross ply veneers of Hemlock or Douglas, 4'x8' panel. *Company Name: BARRIER TECHNOLOGY CORP. 510 4`" Street North, Watkins, MN 55389 Product Description: Blazeguard" sheathing with Pyrotile bonded to A" CDX plywood, 3/8", 15/32", Y.", 5/8" or %" thickness, panel size 4'x8'. *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins, MN 55389 Product Description: Blazeguard" sheathing with Pyrotile bonded to 7/16" oriented strand board (OSB), 3/8", 15/32", A", 5/8" or %" thickness, panel size 4'x8'. *Company Name: BODYGUARD WOOD PRODUCTS 5485 NW Osprey Place, Portland, OR 97229 Product Description: Bodyguard" "V -Rustic" siding Pattern Number 793, 794 and 795, preservative treated pine, minimum 3/4x6 Inches Product Description: dimension, with no through holes or loose knots, installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal Installation only. OCompany Name: BODYGUARD WOOD PRODUCTS 5485 NW Osprey Place, Portland, OR 97229 Product Description: Bodyguard" "RAB Smooth Face R/S" back siding Nos. 371 and 372, preservative treated pine, minimum 1 x6 Inches dimension, with no through holes or loose knots, Installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal installation only. OCompany Name: BODYGUARD WOOD PRODUCTS 5485 NW Osprey Place, Portland, OR 97229 Product Description: Bodyguard" 2 lap siding Nos. 430, preservative treated pine, minimum 1 x6 Inches dimension, with no through holes or loose knots, Installed over oriented strand board (0513) with a 7/16" minimum thickness. For horizontal installation only. *Company Name: BODYGUARD WOOD PRODUCTS 5485 NW Osprey Place, Portland, OR 97229 Product Description: Bodyguard" 3 lap siding Nos. 432 and 433, preservative treated pine, minimum 1 x8 Inches dimension, with no through holes or loose knots, installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal Installation only. OCompany Name: BODYGUARD WOOD PRODUCTS 5485 NW Osprey Place, Portland, OR 97229 Product Description: Bodyguard" cove siding Nos. 771 and 772, preservative treated pine, minimum 1x8 Inches dimension, with no through holes or loose knots, installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal Installation only. *Company Name: CEDAR VALLEY MANUFACTURING 943 San Felipe Road, Hollister, CA95023 Product Description: Cedar Valley FTX Pressure Treated 1 -Course Cedar Shingle Panel, 7-1/8" exposure siding product, Western Red Cedar vertical -grain heartwood shingle, installed over oriented strand board (OSB) with a 7/16" minimum thickness. Fol horizontal installation only. *Company Name: CEDAR VALLEY MANUFACTURING 10 943 San Felipe Road, Hollister, CA95023 *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. Product Description: Cedar Valley "California Stack" 1 -Course Cedar Shingle Siding 10901 Elm Avenue, Fontana, CA 92337 Panel, 4'r4" or greater exposure, Western Red Cedar vertical- Product Description: "Cempanelm" vertical siding, fiber -cement, 5/16" thick. grain heartwood shingle applied over fiberglass matte to a square cut plywood backer, Installed over oriented strand *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. board (OSB) with a 7/16" minimum thickness. 10901 Elm Avenue, Fontana, CA 92337 Product Description: "HardieShingle'"" panel, fiber -cement, 1/4" thick. *Company Name: p Y CERTAINTEED CORPORATION "HardieShingleT" lap siding, fiber -cement, 1 /4" thick. 803 Belden Road, Jackson, MI 49203 Product Description: "Weatherboards'"" lap siding, fiber -cement, type " Smooth, Cedar, Smooth Bead, Textured Bead, Select Cedar, Dutch *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. Lap", 5/16" thick, 5 % to 12" width, 12' length. Product Description: 10901 Elm Avenue, Fontana, CA 92337 "HardiePlankT " lap siding, fiber -cement, 5/16" thick. "HardiePanel'"" vertical siding, fiber -cement, 5/16" thick. *Company Name: CERTAINTEED CORPORATION 803 Belden Road, Jackson, MI 49203 *Company Name: LOUISIANA-PACIFIC Product Description: "Weatherboards'' shapes siding, fiber -cement, type 414 Union Street, Suite 2000, Nashville, TN 37219 "Perfection Shingle, Random Square Staggered Edge, Half Product Description: "LP SmartSidem Precision Series" exterior lap siding, oriented Rounds, Octagons, 5/16" thick, 16" width, 48" length. strand back -bone, 3/8" thick, applied over 1 /2 standard gypsum wallboard. *Company Name: CERTAINTEED CORPORATION 803 Belden Road, Jackson, MI 49203 *Company Name: LOUISIANA-PACIFIC Product Description: "WeatherboardsT"" vertical siding, fiber -cement, type "Stucco, Product Description: 414 Union Street, Suite 2000, Nashville, TN 37219 "LP SmartSidem Precision Series" exterior panel siding, Cedar 8"Groove, Cedar (no groove), Smooth, Octagons, 5/16" thick, 4'" width, 8, 9 or 10' length. oriented strand back -bone, 7/16" thick. *Company Name: LOUISIANA-PACIFIC *Company Name: COLLIN PRODUCTS LLC 414 Union Street, Suite 2000, Nashville, TN 37219 6410 Highway 66, Klamath Falls, OR 97601 Product Description: "LP SmartSidem Fountation Series" exterior lap siding, wet Product Description: TruWoodm 7/16" Sturdy Panel vertical shiplap siding, process fiber back -bone, 112" thick, applied over 5/8" type X Installed over 5/8" Type X gypsum wallboard. standard gypsum wallboard. *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. *Company Name: LOUISIANA-PACIFIC 10901 Elm Avenue, Fontana, CA 92337 414 Union Street, Suite 2000, Nashville, TN 37219 Product Description: "Artisanm" lap siding, fiber -cement, 5/8" thick. Product Description: "LP SmartSidem Fountation Series" exterior panel siding, wet process fiber back -bone, 7/16" thick. *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. *Company Name: ROSEBURG FOREST PRODUCTS Co. Product Description: 10901 Elm Avenue, Fontana, CA 92337 "Cemplankm" lap siding, fiber -cement, 5/16" thick. Description: P.O. Box 1088, Roseburg, OR 97470 "Breckenridge" Siding, 19/32" thick, plain square edge, APA Product it 12 *Company Name: WINDSOR MILL 7950 Redwood Drive #4, Cotati, CA 94931 Product Description: WlndsorONEO 8025 w 1212 preservative treated radiate solid pine wood siding, i x6, 1 x8, and i x 10 v -rustic shiplap siding pattern, with no through holes or loose knots, Installed over oriented strand board (OSB) with a 7/16" minimum thickness. for "Horizontal" Installation only. *Company Name: SHAKERTOWN 1200 Kerron Street, Winlock, WA 98596 Product Description: Shakertownm Craftman- 1 -Course Cedar Shingle Panel, 4-1/2", 7' and 14" exposure siding product, Western Red Cedar vertical -grain heartwood shingle, Installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal Installation only. *Company Name: Various Manufacturers Product Description: Solid "Wood" siding with no through holes or loose knots, Installed over structural plywood or oriented strand board (OSB) with a 7/16" minimum thickness and complying with Voluntary Product Standard PSi or Voluntary Product Standard PS2, with the following Interlocking designs when Installed in accordance with industrial technical guide. Refer to manufacturer's Installations for details. i. Tongue & Groove Shiplaa Loa Cabin: When applied in a horizontal orientation with minimum nominal 6" wide and nominal i" thick board made of wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford 'Cedar", "Alaska Yellow Cedar", "Ponderosa Pine", "Douglas Fir", "White Fir", and "Western Spruce", or other wood species having a Flame Spread Rating not greater than 150 (Class C) when tested in accordance with ASTM E84. 2. Rabbeted Bevel: When applied in a horizontal orientation with minimum nominal 6" wide and nominal 1" thick boards made of a wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford Cedar", "Alaska Yellow Cedar', or other wood species having a Flame Spread Rating not greater than 75 (Class B) when tested In accordance with ASTM E84. 3. Board and Batten: When applied in a vertical orientation with minimum nominal 8" wide and nominal 1"thick boards, and minimum nominal 4"wide and nominal 1.1/4" thick battens, with boards installed with a gap not more than h", with battens fastened to the wood frame with not less than 3" long fasteners at a schedule not more than 24" on center, and boards and battens made of a wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford Cedar", "Alaska Yellow Cedar", or other wood species having a Flame Spread Rating not greater than 75 (Class B) when tested in accordance with ASTM E84. All nominal board sizes shall comply with the.applicable provisions of American Softwood Lumber Standard PS 20. Edge and end glued siding is permitted to be used Interchangeably with solid sawn members. certified siding, Installed over 5/32" CDX plywood sheathing. *Company Name: ROSEBURG FOREST PRODUCTS Co. P.O. Box 1088, Roseburg, OR 97470 Product Description: "Douglas Fir" siding, 11 /32" thick, 12" groove spacing, 1.5" groove width, 3/8' groove depth, shiplap, APA certified siding, Installed over 15/32" CDX plywood sheathing. *Company Name: ROSEBURG FOREST PRODUCTS Co. P.O. Box 1088, Roseburg, OR 97470 Product Description: "DuraTemp" siding, 15/32" thick, 4 ply, 8" groove spacing, 3/8" groove width, lap edge, APA certified siding, installed over 15/32" CDX plywood sheathing. *Company Name: WHISPER CREEK LOG HOMES 997 West 950 North, Suite 100, Centerville, UT 84014 Product Description: "Whisper Creek Log" siding, nominal A round "slices" cut from softwood log, mechanically fastened to 7/16" oriented strand board sheathing and supported on nominal 2" x 6" lumber framing. The log sections measured approximately 9' wide, 3" to 4" at the radius, with a nominal 1" gap between sections. Foamed polyethylene backer rod filled the gap between log sections, providing support to a minimum %z' thick application of UL listed Sashco Sealant, Inc. chinking material. *Company Name: WINDSOR MILL 7950 Redwood Drive #4, Cotati, CA 94931 Product Description: WlndsorONEO 8025 w 1212 preservative treated radiate solid pine wood siding, i x6, 1 x8, and i x 10 v -rustic shiplap siding pattern, with no through holes or loose knots, Installed over oriented strand board (OSB) with a 7/16" minimum thickness. for "Horizontal" Installation only. *Company Name: SHAKERTOWN 1200 Kerron Street, Winlock, WA 98596 Product Description: Shakertownm Craftman- 1 -Course Cedar Shingle Panel, 4-1/2", 7' and 14" exposure siding product, Western Red Cedar vertical -grain heartwood shingle, Installed over oriented strand board (OSB) with a 7/16" minimum thickness. For horizontal Installation only. *Company Name: Various Manufacturers Product Description: Solid "Wood" siding with no through holes or loose knots, Installed over structural plywood or oriented strand board (OSB) with a 7/16" minimum thickness and complying with Voluntary Product Standard PSi or Voluntary Product Standard PS2, with the following Interlocking designs when Installed in accordance with industrial technical guide. Refer to manufacturer's Installations for details. i. Tongue & Groove Shiplaa Loa Cabin: When applied in a horizontal orientation with minimum nominal 6" wide and nominal i" thick board made of wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford 'Cedar", "Alaska Yellow Cedar", "Ponderosa Pine", "Douglas Fir", "White Fir", and "Western Spruce", or other wood species having a Flame Spread Rating not greater than 150 (Class C) when tested in accordance with ASTM E84. 2. Rabbeted Bevel: When applied in a horizontal orientation with minimum nominal 6" wide and nominal 1" thick boards made of a wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford Cedar", "Alaska Yellow Cedar', or other wood species having a Flame Spread Rating not greater than 75 (Class B) when tested In accordance with ASTM E84. 3. Board and Batten: When applied in a vertical orientation with minimum nominal 8" wide and nominal 1"thick boards, and minimum nominal 4"wide and nominal 1.1/4" thick battens, with boards installed with a gap not more than h", with battens fastened to the wood frame with not less than 3" long fasteners at a schedule not more than 24" on center, and boards and battens made of a wood species "Redwood", "Western Red Cedar", "Incense Cedar", "Port Orford Cedar", "Alaska Yellow Cedar", or other wood species having a Flame Spread Rating not greater than 75 (Class B) when tested in accordance with ASTM E84. All nominal board sizes shall comply with the.applicable provisions of American Softwood Lumber Standard PS 20. Edge and end glued siding is permitted to be used Interchangeably with solid sawn members. The recommended installation practice for solid wood siding In wall construction regarding butt and overlapping Joints Is: butt Joints between pieces should be staggered a minimum of 12" and all butt joints should be flush with no gap. Nall joints into the studs or blocking members. One nail at each crossing with the wood frame support member shall be used for nominal 6" siding and 2 nails for nominal 8" or wider siding. Exterior Windows (SFM Standard 12-7A-2) None Under Eave (SFM Standard 12.7A-3) *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins, MN 55389 Product Description: Blazeguardm sheathing with Pyrotile bonded to %_" CDX plywood, 3/8", 15/32", Y.", 5/8" or i." thickness, panel size 4'x8'. *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins; MN 55389 Product Description: Blazeguardm sheathing with Pyrotile bonded to 7/16" oriented strand board (OSB), 3/8", 15/32", %a", 5/8" or %" thickness, panel size 4'x8'. *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. Product Description: 10901 Elm Avenue, Fontana, CA 92337 Product Description: "CemSoffitm" un -vented, fiber -cement soffit, 3/16" thick and Test Protocol W thick. *Company Name: JAMES HARDIE BUILDING PRODUCTS, INC. *Company Name: 10901 Elm Avenue, Fontana, CA 92337 Product Description: "HardieSoffltm" un -vented, fiber -cement soffit, 3/16" thick Product Description: and W thick. Decking (SFM Standard 12-7A-4) *Company Name: ELK COMPOSITE BUILDING PRODUCTS, INC. 9806 Lackman Road, Lenexa, ICS 66219 Product Description: "CrossTimbers FR" composite deck board, I' thick x 5.5" width (nominal 1" x 6"). Test Protocol 12-7A-4, Part A only, Accelerated weathering. Flame Spread Class B *Company Name: EPOCH COMPOSITE PRODUCTS, INC., A TAMKO COMPANY Product Description: 223 South KK Highway, Lamar, MO 64759 Product Description: "EverGrain" composite deck board, 15/16" thick x 5.5" width Test Protocol 12-7A-4, Part A only, Accelerated weathering. Flame Spread Class C (Refer to Exception of 704A.4.1.1 (3) (b)) *Company Name: EPOCH COMPOSITE PRODUCTS, INC., A TAMKO COMPANY Product Description: 223 South KK Highway, Lamar, MO 64759 Product Description: "EverGrain" composite deck board, 1- 7/16" thick x 5.5" width Test Protocol 12.7A-4, Part A only, Accelerated weathering. Flame Spread Class C (Refer to Exception of 704A.4.1.1 (3) (b)) *Company Name: FIBER COMPOSITES, LLC *Company Name: FIBER COMPOSITES, LLC 181 Random Drive, New London, NC 28127 Product Description: "Fiberon" composite deck board, 1 " thick x 5 1/8" width. Test Protocol 12-7A-4, Part A only, Accelerated weathering. Flame Spread Class B *Company Name: FIBER COMPOSITES, LLC 181 Random Drive, New London, NC 28127 Product Description: "WeatherBestT" Meridian" composite deck board, 1 " thick x 5 1/8" width. Test Protocol 12-7A-4, Part A only, Accelerated weathering. Flame Spread Class B *Company Name: FIBER COMPOSITES, LLC Is 1 16 181 Random Drive, New London, NC 2 812 7 Product Description: "Portico" composite deck board, 1" thick x 5 1 /8" width. Test Protocol 12.7A-4, Part A only, Accelerated weathering. Flame Spread Class 8 *Company Name: FIBER COMPOSITES, LLC 181 Random Drive, New London, NC 28127 Product Description: "WeatherSest- Selma" composite deck board, 1 " thick x 5 Is 1 16 1/2" width. Test Protocol 12.7A-4, Part A only, Accelerated weathering. Flame Spread Class C (Refer to Exception of 704A.4.1.1 (3) (b)) *Company Name: FIBER COMPOSITES, LLC Ignition -Resistant Materials (ASTM E84 for 30 Min. with Accelerated Weathering Test) *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins, MN 55389 Product Description: Blazeguardm sheathing with Pyrotile bonded to W COX 181 Random Drive, New London, NC 28127 Product Description: "Veranda" composite deck board, 1 " thick x 5 1/8" width. Test Protocol 12-7A-4, Part A only, Accelerated weathering. Flame Spread Class B *Company Name: TREX COMPANY, INC. 245 Capitol Avenue, Winchester, VA 22601 Product Description: "Trex Accents: Fire Defense" wood and polyethylene *Company Name: composite deck board, nominal 5/4" thick x 5-1/2' width, nominal density of 0.036 Ib/In'. Test Protocol 1 2.7A-4, Part A only, Accelerated weathering. Flame Spread Class B *Company Name: Various Manufacturers Product Description: Solid "Wood" decking: "Redwood", "Western Red Cedar', "Incense Cedar", "Port Orford Cedar", and "Alaska Yellow *Company Name: Cedar". Sizes: Minimum nominal 2" thickness (American Softwood Product Description: Lumber Standard PS 20). Lumber grades: Construction Common and better grades for Redwood, 3 Common and better grades for Cedars, and Commercial decking or better grades for both Redwood and *Company Name: Cedars. Special instructions: solid wood decking shall be Installed Product Description: over 2"x6"solid "Doug Fir" or better jolsts spacing 24" or less on center. Flame Spread Class C (Refer to Exception of 704A.4.1.1 (3) (b)) Ignition -Resistant Materials (ASTM E84 for 30 Min. with Accelerated Weathering Test) *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins, MN 55389 Product Description: Blazeguardm sheathing with Pyrotile bonded to W COX *Company Name: HOOVER TREATED WOOD PRODUCTS, INC. 154 Wire Road, Thomson, GA 30824 Product Description: "EXTERIOR FIRE X" pressured Impregnated treated plywood (Douglas Fir, Micro -Lam Douglas Fir, Southern Yellow Pine, Gang -Lam Southern Yellow Pine, Micro -Lam Southern Yellow Pine, Spruce Master Plank). (CSFM Listing No. 2580- 1701:101) Wood Shapes and Shingles Roofing Materials (UBC 15-2) is 17 plywood, 3/8", 15/32", W, 5/8" or''/." thickness, panel size 4'x8'. *Company Name: BARRIER TECHNOLOGY CORP. 510 41" Street North, Watkins, MN 55389 Product Description: Blazeguardm sheathing with Pyrotile bonded to 7/16" oriented strand board (OSB), 3/8", 15/32", Y.", 5/8" or Y.." thickness, panel size 4'x8'. *Company Name: CHEMCO INC. 4191 Grandview Road (P.O. Box 875), Ferndale, WA 98248 Product Description: Type "FRX" and "Thermex-FR" fire -retardant -treated lumber. Products are Douglas Fir, Southern Yellow Pine, Western Red Cedar, White Spruce and Western Hemlock pressure Impregnated with "FRX" and "Thermex-FR " fire retardant chemical. *Company Name: CHEMCO INC. 4191 Grandview Road (P.O. Box 875), Ferndale, WA 98248 Product Description: Type "FRX" and 'Thermex-FR" fire -retardant -treated plywood. The plywood is Structural I grade, exterior plywood complying with PSI. Products are pressure Impregnated with "FRX" and "Thermex-FR " fire retardant chemical. *Company Name: HOOVER TREATED WOOD PRODUCTS, INC. 154 Wire Road, Thomson, GA 30824 Product Description: "EXTERIOR FIRE X" pressured impregnated treated lumbers (Douglas Fir, Southern Yellow Pine, Western Red Cedar, Redwood). (CSFM Listing No. 2520-1701:100) *Company Name: HOOVER TREATED WOOD PRODUCTS, INC. 154 Wire Road, Thomson, GA 30824 Product Description: "EXTERIOR FIRE X" pressured Impregnated treated plywood (Douglas Fir, Micro -Lam Douglas Fir, Southern Yellow Pine, Gang -Lam Southern Yellow Pine, Micro -Lam Southern Yellow Pine, Spruce Master Plank). (CSFM Listing No. 2580- 1701:101) Wood Shapes and Shingles Roofing Materials (UBC 15-2) is 17 V1 Butte County Department of Development Services TIM SNELLINGS, DIRECTOR I PETE CALARCO, ASSISTANT DIRECTOR 7 County Center Drive Oroville, CA 95965 (530) 538-7601 Telephone (530) 538-7785 Facsimile www.buttecounty.netldds FACE OF FOOTING TOP OF SLOPE FACE OF STRUCTURE TOE OF M BUT NEED NOT H SLOPE EXCEED 40 FT. (12 192 mm) MAX I M12 BUT NEED NOT EXCEED 15 FT. (4572 mml MAX. BUILDING CLEARANCE FROM ASCENDING SLOPES X1. REQUIRED SETBACK RETAINING 1 �� W WALL) / STEEPER THAN 1 T0.1 -j L, `-J TOE FOR PURPOSES OF FIGURE 1 B-1-1 FOOTING SETBACK FROM DESCENDING SLOPE SURFACE STEEPER THAN 1 TO 1 j L X1. REQUIRED SETBACK POOL SETBACK EQUAL TO f ONE-HALF BUILDING FOOTING N- 7 FT. (2134 mm) SETBACK DISTANCE AS REQUIRED BY FIGURE 1 B-1-1 FOR SLOPES STEEPER THAN 3 TO 1 SLOPED BUILDING SITE'S 3-1 ;-06 STRUCTURE SETBACKS FOR PURPOSES OF FIGURE 18-1-1 i PORTIONS OF POOL WITHIN 7 FT. FI34 mm) SHALL BE CAPABLE OF SUPPORTING WATER WITHOUT SOIL SUPPORT 13 Butte County Building Division UFACTURED HOME SUPPORT DATA Owner's name:_ Home Manufacturer:�� A. ©5 -- Cp Model Num er / Name: I Manufacture Year:' Width: a(op �� (ft) Length: -b - ft. FOOTINGS: Wood -pressure treate�o� fofoundationrad SUPPORTS: Concrete block Other:[ ] 9 Other:[ ] Provide manufacturer's installation manual support requirements and state approved or engineered foundation or tie down system specifications. Pier Footing Sizes and Locations SINGLE WIDE Line 1 Line 2 �� _ Section 1 Line 1 Section 2 Section 3 Line 1 Piers: Minimum size piers: X Spacing maximum: d From ends maximum: Line 2 Piers: Minimum size piers: Spacing maximum: From ends maximum: Line 3 Roof Loads: Minimum size piers: Location (from front): Minimum size piers: Location (continued): Line 4 Roof Loads: Minimum size piers: Location (from front): Minimum size piers: Location (continued): /2 ~ X oj�. MULTI -WIDE Line 1 Line 2 Line 3 Line 2 Line 4 (triple wide only) Line 2 - -Snow Load: psf Snow Load requirements may be obtained at httP://www.upstate-ca-Com/butte/bufte—County/ Insert AP #, view snow load in lower right comer. Line 1 Openinos Minimum size pier: [/a? j X [ a3l j Re uired at each side of openings over wide. r,v )02 awl,5�1001VOVI-av I i I O OPT. I SDa Ld I � r;. L ^ �j 1 � roTEs: P - 3 � � � • _ A L TBS FUDI ULAN INT,K MALT 91 AN E11AC1 HkO MAM-A *= R8 LOM 1610E TOILE► 9440 M1D,111 (W -To i0 EM) M. ►OST NO SPLICE SAO PUNS OIS fUOIA'TI€ 01*016) ARE TO SE STARTED AT T)i SEAR Of 60-TOOD MR" WM. TH8 FLOOR PLM AID ATTA0 0 OPTION DETAIL$ (IF AFPMICAOLE) IS 0E800 TO IEET TIE FOLLAM STRUCTURAL KWIAEIIS:9T8; WSD IOIE(8) I ROOF LO $) 30 Ibl. n >< w PERIMETER PIERINO REQUIRED WHEN ROOF LIVE L('AD ) 20 PII 5 L E G E N D 1--I RECE P I ACL E SWI ICN O lFf lik" T A T ® SMOKE ALARM SMOKE ALARM WN19. k" I0 VLIGNT FIXTURE ® EXWIUSI FAN ® VIDEO DIGITAL CARIE PAFEL EO ® VIDEODIGITAL CAELI CUTLET FAN FAN W/LIGN IFANEL 80X RAG RETURN AIR y GRILLE q a FLOOR "MR aloss-0VEit LOCATION / AIR IUPPLT O4FPORT POST Q OfARIVALL pA 160 L $a-8' pe 160 X $a-8• © L WOOOLAW n IN=? Rom WATERFORD mm 4513B OLMM TIME FLOOR PLAN Dower: AIVAR K. aa: OV12104 M KY FP.1 . n. to ZE-Dr 11-! 1/Z DRAIN OUTLET X01 n OAS INLET a } n --------------------fl--------------o-------o, _E ISE n LEM DVCEll-c ON CT10T46ffaf_,OM A�.NIi y ®I I I 1�? -------------- - 1r.D1YFlf,illEtTJ7� y/ - ,y_+ ILlR Kpc T CONNECTION O�JN1T I >1 1�------- -------❑---�—❑-------❑---a❑-------aJ za-s•� � Dr m Lr tfARIVALL 4 -STRAP mm Doi I LUAU- uoo .• 33ov ISEO Y V , u 0 00 PERIMETER PIERIN3 FOR A HOME WITH 2X4 SIDEWALLS PERIMETER PIERING REOUIRED WHEN ROOF LIVE LOAD ) 20 p11 CHASE I S--1 NFC Y.R. SPACINO IS 1 -SEAM SIZE L E Qioo7lTAWK. "CO71Fw IHS DRAWIPL SOL WAND 17-1 IICT IME WATERFORD 45138 ■aw TIRf PIER LAYOUT 301 ROOF LOAD Lvmoy: AKAR K. "rt: 04/19/04 I.XO M SP.E.I E. tr A /1 Al �I Xi2 Foundation System, Installation Instructions for California for Ground & Concrete Systems California Building Code (CBC) 2007 Wind 85 mph, Exposure C; Seismic Design Category D By Tie Down Engineering May 16, 2008 Xi2 Concrete System Engineer Approval State Approval IU=FACMFD ROMVMOWM ?xoM2 FOUNDATION SYSnM APPROVED. SLl�3E4`�`.'�U iAARL'.G3'P�3I+H)7RD APPROVAL UA NOT At ORIZU. R APPR(VS A . OMISSIONS OR VE'1t'lATt0NFROM 1ktQWREMEM O APPLICABLE STATE LAWS AND RROUL.A"[ ONS St¢1a oiCmfiCanut D*WtMW d HOWSS VW Ca MUSIty (JF Q0 AND STA"A*Mf � BUTTE c ' ��L4 I .7) r•).. Page 1 of 8 Xi2 Foundation System Installation Instructions for California for Ground & Concrete Systems CBC -07, 85 mph Wind Exposure C; Seismic Category D By Tie Down Engineering REQUIREMENTS • These plans and specifications meet the requirements of Title 25 Section 1333 and Wind & Seismic Requirements, CBC 2007. • Maximum vertical projection at sidewall is 9'. Higher walls may be used when the design loads are adjusted accordingly and approved by HUD. • Main rail spacing must be 75.5" - 99.5" * Except single sections 95" minimum • Additional vertical anchor ties that are unique to a home's design may be required by the home manufacturer. These locations may include shear walls, marriage line ridge beam support posts, and rim plates. The longitudinal component of the Xi2 system replaces end frame ties. Check manufacturers set-up requirements. • Maximum pier height is 48" pier. *Except for single sections 36". • Steel piers must be fastened to the I-beam with clamps provided with steel pier. • Systems must be placed as evenly as possible, no more than 10' from end of home. • Designed for 7:12 roof slope. *Except single sections, (20° - 4.37 in. 12" pitch). Additional Requirements for Concrete Systems • Poured concrete must be 2,500 PSI minimum at 28 days. • Square concrete pads minimum is 18" wide by 12" deep. Round concrete pads minimum is 18" wide by 14" deep. Strip footings minimum is 18" wide by 14' long by 6" deep. * Xi2 components exceed HUD code 3280.3068 "Anchoring equipment exposed to weathering shall have a resistance to weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 ounces per square foot of surface coating...." Page 2 of 8 0 0 0 Owner: dokoe-' REVISION: BP# 06—/61/y APN: 0s0-- c/ya - vo �2> Date /8101 FILE COPY 0 6 Zz. % tP `mac"FLEFIWOOD. HOMES Waterford Series Model 4513B Bedrooms • 2 Baths • 1,X -US; are e OI{'WP L' 1 2 - a OPT CUT CORNER BATH OPT. MORNINC, ROOM ENrRY DP(. A(RIUM A104 J L OPT. S.O.D. �......f :.:a.I. :.OESX "MORNIlJG"� l .� s f ROOM.E'' _ 010 MrlIR3r lJ i �" 0 OPT. ATRIUM OOOr Orr. p On. 9.0.0. ; 1 WAI;:IN ow .....i..4..1. 1 ..BFORnnu ea P7 ` ..._!... ; _: Oil .,.., _ DINING AREA T nu. C 0 j'1 I = i' 4 +BATF. .....I. Orr. p MASTER BEDROOM / \ OPr. BATH QT. TONER P01 I DORMER r� ' Ali ,.DarNEa 1 AN T r ; T 4 v 1 i � i :LIVING ROAt I I � 1 PT. DEN #2 10'-3"X 9'-4• L\W/EOXED i OORMER MOEIGAW DOrNFR I .._ ;.I OPT. CORNER BAY LT. ENTRY DOOR LOCATION OPT. RECESSED O .ANGLED ENTRY RECESSED ENTRY Fleetwood Homes reserves the fight to change- colors, prices, specifications. models, dimensions and materials without notice. Rendering and diagrams are meant to be representative arid, in keeping wth'leetwood's policy of cowstant updating and improvernea may vary from the actual hot?*.. All dimensions are c:ominal and approximated. Square footage is measured from exterior wall to exterior wall, and 6 an approximate figut- Length indicated rn Rc<;rplant i5 floor length only. The length of the hitch -is not ;ncleded. (Add four feet to are:;e at transportable length.) Ask your retailer for specifics. PRICES AND SPECIFICATIONS SUBJf-CTTt:1''t?ANGE WITHOUT NOTICE OR 001.1 ,ATION. F- kW49- Ii%Gari; ' �c"FLEACE7 JW0 D. HOMES OPrT. MOuR�NING. ROOM^MEEWRY C !. A MiU11 DOOR OPT, S.G.D. G.0 IY;NFI; ( tur —o;�;: 0- L 441111 0 -L:4'-C.7 0H OPT. DEN A'2 r'OPLL DORNE� r /aanya 1 �--....,,__,.-1_._. 10'•3' x 9'r' OP.''CUTCORNER off. OATH • _ lr %OATHS . I Waterford Series Model 4513B 3 Bedrooms -2 Baths • 1,350 Square Feet o � tp e EAN s j BEDROOM d2 (OPr.ORL3AM j �j `� �W/OOYEOOUT it9W DR. COREDOUTWDW. W/O[RinW ODRNER OPT. CORNER BAY f OPTEECE SED Wux-w' amir ----j Fleetwood Homes reserves the Tight to change colors, prices, specifications, models, dimensions and materials without notice. Rendering and diagrams are meant to be representat • = 1•r, rM.f+ T updating and irnprovernenl; may yaiy Dorn the actual home. All dimemiuns are nominal and approxin'Ialed. Square footage is rneasured from exterfor wall to exteiicn wall, and is arl length only. The length of the hitch is not included. (Add four feet to arrive at transportable length.) Ask your retailer for'specihcs. PRICES AND SPECIFICATIONS SUBJECT To CHANGE PFSAPPfrnV•il._I I; 12!11% in keeping wlth'IeetwLvd's poliq+of co'Istant male fiqure. Length indicated in Bc.-o(pI:,ns is floor �NOTICF. OR OBLIGATION. 'st:F/l7/pit �c:? OPT. DEN A'2 r'OPLL DORNE� r /aanya 1 r / RAN / 10'•3' x 9'r' �, 9• OPf. A. DOOR ' � ASTER EDR M y ' ' 'LIVING Rbo)w o axyr-e i / r7-e'x 13'•0' i , , r0� OA TONtR DORMER ALT. ENTRY DOOR LOCA BEDROOM t � 1aa•x9i• x^ ' ., I_: 11,1'� = orL OPT STUDY DINING 1's� u 1a•sx3•1-3'X9'-4" +' AREA 19 xv-o nN a. D o � tp e EAN s j BEDROOM d2 (OPr.ORL3AM j �j `� �W/OOYEOOUT it9W DR. COREDOUTWDW. W/O[RinW ODRNER OPT. CORNER BAY f OPTEECE SED Wux-w' amir ----j Fleetwood Homes reserves the Tight to change colors, prices, specifications, models, dimensions and materials without notice. Rendering and diagrams are meant to be representat • = 1•r, rM.f+ T updating and irnprovernenl; may yaiy Dorn the actual home. All dimemiuns are nominal and approxin'Ialed. Square footage is rneasured from exterfor wall to exteiicn wall, and is arl length only. The length of the hitch is not included. (Add four feet to arrive at transportable length.) Ask your retailer for'specihcs. PRICES AND SPECIFICATIONS SUBJECT To CHANGE PFSAPPfrnV•il._I I; 12!11% in keeping wlth'IeetwLvd's poliq+of co'Istant male fiqure. Length indicated in Bc.-o(pI:,ns is floor �NOTICF. OR OBLIGATION. 'st:F/l7/pit �c:? r'OPLL DORNE� r /aanya 1 r / RAN / FAN ' � ASTER EDR M y ' ' 'LIVING Rbo)w o axyr-e i / r7-e'x 13'•0' i , , r0� OA TONtR DORMER ALT. ENTRY DOOR LOCA o � tp e EAN s j BEDROOM d2 (OPr.ORL3AM j �j `� �W/OOYEOOUT it9W DR. COREDOUTWDW. W/O[RinW ODRNER OPT. CORNER BAY f OPTEECE SED Wux-w' amir ----j Fleetwood Homes reserves the Tight to change colors, prices, specifications, models, dimensions and materials without notice. Rendering and diagrams are meant to be representat • = 1•r, rM.f+ T updating and irnprovernenl; may yaiy Dorn the actual home. All dimemiuns are nominal and approxin'Ialed. Square footage is rneasured from exterfor wall to exteiicn wall, and is arl length only. The length of the hitch is not included. (Add four feet to arrive at transportable length.) Ask your retailer for'specihcs. PRICES AND SPECIFICATIONS SUBJECT To CHANGE PFSAPPfrnV•il._I I; 12!11% in keeping wlth'IeetwLvd's poliq+of co'Istant male fiqure. Length indicated in Bc.-o(pI:,ns is floor �NOTICF. OR OBLIGATION. 'st:F/l7/pit �c:? RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 1 999-004'3602 Recorded I REC FEE .00 OfficialRecordsI CONFORM .00 Count �I BOfUTTE 7 COUNTY CENTER DRIVE CANDACE J. GRUBBS I Recorder I ROSEMARY DICKSON I Assistant I Maureen 11:20AM 29 -Nov -1999 I Page 1 of 3 SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, i INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of d,.e.,real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ROBERT J. BAKER & PATRICIA A. BAKER BUTTE COUNTY BUILDING DIVISION REAL PROPERTY OWNERILESSOR LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 2151 GRAND AVENUE 7 COUNTY CENTER DRIVE MAILING ADDRESS MAILING ADDRESS OROVMLE, BUTTE, CA 95965 OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP CITY COUNTY STATE ZIP 3540 STONE MOUNTRAIN ROAD 99-1894 (530)538-7541 INSTALLATION MAILING ADDRESS, IF DIFFERENT BUILD PTELEPHONE NUMBER OROVILLE, BUTTE, CA 95965 11/29/99 CITY COUNTY STATE ZIP SIGNATURE OF LOCAL AGENZ7ZTVCLAL DATE SAME NONE UNIT OWNER (if also property owner, write "SAME") DEALER NAME (d'not a dealer sale, write "NONE") MARLING ADDRESS DEALER LICENSE NO. cm courrrY sn� UNIT DESCRIPTION r8 FLEETWOOD 1997 SUNCREST MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMEINUMBER CAFLV17A/B202934 1 44'X 24' RAD1010685/6 SERIAL. NUMBER(S) LENGTH X WIDTH INSIGNIAILABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER A.P. #6-58-44-0-0-08,, SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE - County Recorder CANARY - HCD PINK - Applicant GOLDENROD- Building Dept LEGAL DESCRIPTION A.P. #058-440-008 All that certain real property situate in the County of Butte, State of California, described as follows: Parcel One: Parcel 1, as shown on that certain Parcel Map, filed in the Office of the Recorder of the County of Butte, State of California, on March 6, 1972 in book 41 of Maps, at Page(s) 43. Parcel Two: Being a portion of the L. Ferro Tract as shown on that certain Record of Survey map of Section 21, Township 22 North, Range 4 East, M.D.B. & M., as recorded May 14, 1968 in book 33 of maps at page 37, and being more particularly described as follows: A non-exclusive easement for road and public utility purposes over strip of land 60.00 feet in width lying 30.00 feet on each side of the following described centerline: Beginning at the Northeast corner of that certain parcel of land conveyed in deed to Wm. R. Tindle, et ux recorded in book 1520 at page 563, Butte County Official Records and being as shown on that certain record of survey of a portion of the East half of Section 21, Township 22 North, Range 4 East, M.D.B. & M. For David W. Harper, et al which map was filed in the office of the Recorder of Butte County, in book 33 of maps at page 46; thence following along the Northerly boundary line of said Tindle parcel, North 79 deg. 20'58" west for a distance of 68.15 feet thence following along the arc of a 550.00 foot radius curve concave to the Northeast, Southerly through a central angle of 7 deg. 55'52" for an arc distance of 76.13 feet to the beginning of a 450.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 3 deg. 22'44" for an arc distance of 26.54 feet to a point therein, said point being the true point of beginning for the centerline herein described; thence South 55 deg. 4544" West for 36/08 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 45 deg. 34'52" for an arc distance of 79.55 feet to the end of said curve; thence South 10 deg. 10'52" West for 213.78 feet to the beginning of a 300.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 11 deg. 1710" for an arc distance of 59.09 feet to the end of said curve; thence South 1 deg. 06'18" East for 236.19 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through as central angle of 176 deg. 02'56" for an arc distance of 307.26 feet to the end of said curve; thence North 5 deg. 03'22" west for 247.14 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 59 deg. 2357" for an arc distance of 103.67 feet to the end of said curve; thence North 64 deg. 26'37" West 64.25 feet to the beginning of a 200.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 22 deg. 16'28" for an arc distance of 77.75 feet to the end of said curve; thence North 42 deg. 10'09" West for 139.04 feet to the beginning of a 100.00 foot radius curve to the left; thence following r along the .� Page 2 Legal Description AP # 058-440-008 arc of said curve to the left through a central angle of 25 deg. 38'48" for an arc distance of 44.76 feet to the end of said curve; thence North 67 deg. 48'57" West for 186.17 feet to the beginning of 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 22 deg. 39'30" for an arc distance of 39.50 feet to the end of said curve; thence North 45 deg. 09'27" West for 35.09 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 23 deg. 36'40" for an arc distance of 41.21 feet to the end of said curve; thence North 68 deg. 4607" West for an arc distance of 140.00 feet to the beginning of a 300.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 4 deg. 46'04" for an arc distance of 24.96 feet to the end of said curve; thence North 73 deg. 32'11" West for 39.91 feet to the beginning of a 200.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 19 deg. 2720" for an arc distance of 67.91 feet to the end of said curve; thence South 87 deg. 00'29" West for a distance of 103.72 feet to the end of said centerline, said road easement is to include 20.00 foot radius returns at the intersection with the Oroville-Concow Road. The boundaries of said easement are to be lengthened or shortened to meet the property lines involved. Said road easement is for the benefit of and appurtenant to the lands of the grantees herein and shall inure to the benefits of and may be used by all persons who may hereafter become the owner of said appurtenant property of parts or portion thereof. E.H. SE ONLY Plot Plan Attached Floor Plan Attached i Sent to B.D. / TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Owner . Location AP# Plan Approved for: Sewage Disposal----�,. Water Supply: Public Private Well Clearance for dwelling. Other P Q /�j�Y`? �z-P ,L-jjo Hold final for: Final cleaafr/cjnce O K. for: NOTE: //lel//1�C�/!�1 5,0� `�-WICFI1_S//'G-'Health Specialist Environmental 8/96 Date w J AV =(=qw I � W-,Ap . H O M E S Westfield Series Model 6522L APPROVED Butte County Environmental Health (WL __ -L. v r it WP„7,APR98 • II rtj (.2243 4 -cm Tr'Y 1 FEATHER .. (530)532-3301 COU -I ! L ;nuir L)rivE oroviffe, Ca 2 Bedrooms -1 Bath - 806 Square Feet Exterior • Embossed fiber cement siding built to resist weather damage • Full 4:12 roof pitch for exterior eye appeal • 2" x 4" exterior wall construction provides a sturdy frame • Transverse floor with 2" x 6" floor joists for better support (2" x 8" on 16' wide) • Owens Corning® Class -A fire -rated composition shingle roof for long lasting performance • Vented roof cavity releases hot air and condensation for increased energy -efficiency Interior • Decorative vinyl -covered gypsum wall panels are easy to clean • 18 oz. carpet in all living/bedroom areas for high performance and low. maintenance - 100% nylon prevent fuzzing and shedding - Multi -colored dye technique minimizes tracking and spotting -Treated with Scotchgard" for easy cleaning • Acoustical vaulted ceilings throughout provides an open look and feel Baths • Easy -care laminate countertop with 4" ceramic tile backsplash protects walls from water damage and adds color to your decor • Recessed medicine cabinet provides convenient storage space in each bath • Ceiling exhaust fan provides'extra ventilation in each bath • Window in each bath draws in natural light • Moen® 4" dual lever faucets and' single -lever shower faucets -"Buy it for looks. Buy it for life" Kitchen • Maytag® appliances provide name brand confidence and hassle -free service • 30" free standing gas range • 15 cubic ft. frost -free refrigerator • Moen® single -lever metal faucet -"Buy it for . looks. Buy it for life" • Bank of 4 drawers provides convenient storage for your utensils • Double cell porcelain sink adds flexibility in kitchen activities • Congoleum® no -wax, vinyl flooring is easy to clean • Elegant crown molding adds a finishing touch to overhead cabinets Utility, Safety and Energy Features • Inside mount, 100 AMP panel box offers easy access • Overhead utility shelf expands your storage space FLEETWOOD. ONE YEAR I FIVE YEAR Note that square footage is measured from exterior wall to exterior wall, and is an approximate figure. Length indicated in . • floorplans is floor length only. Renderings and diagrams are meant to be representative and, in kdeping with Fleetwood's policy of constant updating and improvement, may vary from the actual home. All dimensions are nominal. Ask your retailer for specifics. (Add four feet to arrive at transportable length.) PRICES AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. LIMITED WARRANTY �� 01996 • .Zone II insulation package increases energy - efficiency - Includes:.white vinyl framed dual -paned windows, R-22 ceiling, R-11 sidewalls, R-11 floor insulation - the higher the "R value, the better the insulation. • 30 gallon electric water heater is efficient and easy to maintain • Intertherm® gas furnace provides name brand confidence and hassle -free service. Optional Features • Dishwasher and garbage disposal make kitchen clean-up quick and easy • Inswing entry door with deadbolt, peephole, and brass knocker for your family's s ifety • 2 x W sidewalls with R-19 insulation to increase your home's energy -efficiency • Zone III insulation package meets 'the challenges of your climate - Includes: white vinyl framed, dual -paned windows, 2" x 6" exterior walls with R-33 ceiling, R-19 sidewall, R-22 floor insulation • 2nd bath for.the 6522L provides privacy and convenience FLEETWCOD 1111111111111113 .FLEETWOOD HOMES of CALIFORNIA, INC. a subsidiary of.Fleetwood Enterprises, Inc. 18 N. Pioneer Ave., P.O. Box 1308 Woodland, CA 95776 (530) 662.3223WRIVAUG98 j-) V/Zzp .S�erl-e 10 i �q 7 Co Ur`6vv;illle. Cp COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - OrovilleCalifornia 95965 -Telephone (916) 538-7541 P RMIT NO./ APPLICATION' AND PERMIT 9 Ll ~ `'� � ASSESSOR PARCEL NUMBER 058-440-008 ZONING FR -10 BUILDING PERMIT OWNER JOSE kERCADO TELEPHONE SO. FT. OCC. BUILDING VALLMTION OWNERS MAILING ADDRESS 3824 PRESDIO ST. SACRA14ENTO CA 95838 CONTRACTOR'S NAME 014NER TELEPHONE , ' CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE N0. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS SW ME r,.MOUNTAIN RD & CONCON PERMIT FEE $ PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 CO Solar or heat pump water heater 23.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP ELMAP Water piping P P 9 15.00 Each gas water heater or vent 15.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other ELE FOP, 14ELL SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G W @20.00 TYPE OF WORK New ❑ Addition ❑ Remodel ElUtilities ❑ Installation ID Other Describe Work: PERMIT FEE $ Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service ( 10V OR 200AORLESS ) 23.00 23.00 Main Service ( 200A TO 1000A ) 46.00 NEW CONST. DWELLING OCCUP. g, OR ADONS. 1 & ACC. BLOS. ) 3.50 FT0. CONTRACTORS LICENSE LAW declare under penalty of perjury (check one) ❑ 1 am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification 1, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) ❑ 1, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) O 1 am exempt under Sec. Business and Professions Code forthis reason NEW CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS ) 8 SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) B20@r.00 Ex. Occup.FIXED APPWS. OR ( OUTLETS IflESID.1 EA. ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 F_ N1 SPECTI ON 23.00 WORKER'S COMPENSATION INSURANCE declare under penalty of perjury (check one): O This permit is for $100.00 (valuation) or less. O I have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a ertificate of Consent to Self -insure. hall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 66.00 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Contractor I certify that 1 have read this application and state that the above information is correct. 1 agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the grantin of this permit. X Date Sig aure of Applicant A Owner ElContractor ❑ Agent A SHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEES 56.00 HA?. I D. FEES 1 IMP 1 FLOOD I CDF PARCEL PO HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. p� By !�/GV�'' ate C `7 q PERMIT EXPIRES ON /� %•Z /s (D e) Receipt No. {O (p WHITE-D.D.S.-B.O. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTYOF BUTTE - DEPARTMENTOF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA95965 -TELEPHONE (916) 538-7541 OWNER Proposed Building Use PERMIT APPLICATION DATA SHEET Building Inspector MU1041 Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: 1. All items have been submitted. 2. Plot plans, 3/4 sets, signed by preparer of plans. 3. Complete plans, 3/4 sets, signed by preparer of plans. 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans. 5. Hazardous Material Form. 6. Energy Design Compliance and supporting documentation. 7. Statement of Intent for Non -Heated and A/C Buildings. 8. Engineered truss details and layout in duplicate (required prior to plan check). 9. Mobilehome data and manufacturer's installation instructions, 2 sets. 10. Fees of $ 11. Impact fees as shown on attached schedule. 12. California Department'of Forestry plan approval/fees. 13. Flood elevation letter (100 year flood) by California Engineer. 14. Sanitation and plot plan approval Health Department. 15. City of Chico plumbing permit. 16. Plot plan and business license approval from City of Biggs/Gridley. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. 19. Driveway permit (construction approval required prior to occupancy). 20. Pre -inspection for . D I-P, required. 21. Contractor's license information. (No., Name Style, Classification). 22. Certificate of Workmans Compensation Insurance. 23. Owner -Builder Verification (Given to owner , Mail to owner . 24. Recorded copy of Agricultural Acknowledgement Statement. 25. Letter of signature authorization. 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. 27. Letter of intent on building use. 28. Mobilehome utility clearance. 29. Documentation of legal access. 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements. 31. Existing violations/expired permits. 32. Plan check list. 33. 34. When you issue the permit, process as follows: Mail to owner. Mail to contractor. Telephone and hold for pickup at office. Deliver with inspector. Other Applicant W-200000�,NAINZNQ� EXPIRATION OF APPLICATION Applications for which a permit has not been issued, will expire by limitation one year after date of application. In order to renew action on an application after expiration, a new application; plans and fees will be required. FEE REFUNDS Refunds can only be made upon writtten request by the person who paid the fee. The request must be made within one year from the date of fee payment on permits not issued, and one yearfrom the date of permit issuancefor permits issued; however, on issued permits refunds can only be made if no construction work has been done. Filing fees, plan checking fees for work plan checked. and other department costs are not refundable. Original - Applicant '7T'�'{�:*.�i��7� � .. ' y[3w1�^w'� ^epi`sln-:.rK�1'w#'t'f�ilrrtlj"!�'��'l l[�}✓'�.'r'',�.4��„"'. COU NTYOF BUTTE - DEPARTMENT OF ,EVELOPMENTSERVICES - BUILDING DIVISION ..` x 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA95965 -TELEPHONE (916) 538-7541 / . PERMIT APPLICATION DATA SHEET V OWNER A. P. No. Proposed Building Use Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. All items have been submitted......................................... 2. Plot plans, 3/4 sets, signed by preparer of plans. ......................... . 3. Complete plans, 3/4 sets, signed by preparer of plans. ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans. ............. 5. Hazardous Material Form.............................................. 6. Energy Design Compliance and supporting documentation . ................... 7. Statement of Intent for Non-Heated and A/C Buildings. ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). .... 9. Mobil home data and manufacturer's installation instructions, 2 sets. ........... 10. Fees of $ .......................................... 11. Impact fees as shown on attached schedule. ............................. . 12. California Department of Forestry plan approval/fees. ....................... . 13. Flood elevation letter (100 year flood) by California Engineer. ................. . 14. Sanitation and plot plan approval Health Department . ............ 15. City of Chico plumbing permit........................................... 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. 20. Driveway permit (construction approval required prior to occupancy). . . .Pre Inspection revue q Pre-inspection for D:�e� required. to Building Inspector�74-1 20%M 21. ... Contractor's license information. *(No., Name Style, Classification). .............. 22. Certificate of Workmans Compensation Insurance. .......................... 23. Owner-Builder Verification (Given to owner , Mail to owner _). ........... 24. Recorded copy of Agricultural Acknowledgement Statement. .................. 25. Letter of signature authorization......................................... 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. .... . 27. Letter of intent on building use.......................................... 28. Mobilehome utility clearance.......................................... . 29. Documentation of legal access . ..................... :.................. 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements. ................ 31. Existing violations/expired permits....................................... 32. Plan check list . ..................................................... 33. 34. .. ` When you issue the permit, process as follows: ail to owner. Mail to contractor. Telephone and hold for pickup at office. Deliver with inspector. Other Parcel Creation Acreage - Applicant Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior•to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Plans checked by Date Plans approved by Date Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works COUNTY OF BUTTE Department- of Development Services Building Division Oroville: 7 County Center Dr., Oroville CA 95965 Ph: 916-538-7541 Chico: 1469 Humboldt Rd., Chico CA 95928 Ph: 916-891-2751 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earldest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) 2. I (have/have not) AU signed an application for a building permit for the proposed work. 3. I have c Name Address Phone 4 with the following person (firm) to provide the proposed construction: I plan to provide, provide the major Name Address Phone City Contractor's License No. of this work, but I have hired the following person to coordinate, supervise, and City Contractor's License No. 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: GA e Property Owner Social Security Number ' — Date . RrI36/gV NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. co U�p Ode o6,p�F 9S� COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES, BUILDING DIVISION 7 County CPhone:Y enter D916 ive�5 8�7541e CA 95965 COUN OF1p�jgTG JOSE MERCADO 3824 PRESIDIO ST. SACRAMENTO, CA 95838 RE: APPLICATION FOR ELECTRIC SERVICE DATE: 8/24/94 A.P. # 058-440-008 With reference to the above subject: Attached is: _K_Application for permit Mobilehome Utilities Installation Sheet Building Plans Mobilehome Installation Information Sheet Engineered Calculations - Typical Plan Sheet Owner -Builder Verification Fm List of Codes.Enforced We need the following information prior to permit processing and/or issuance: _Permit application signed and completed where indicated with all copies returned. Plot plans, 3/4 sets, signed by preparer of plans. 'Complete plans, 3/4 sets, signed by preparer of plans. Engineered plans and calcs, 3/4 sets, with wet signature on plans. Hazardous Material Form Energy Design Compliance and supporting documentation. Statement of Intent for Non -Heated and A/C Buildings. Engineered truss details and layout in duplicate. Mobilehome data and manufacturer's installation instructions, 2 sets. X Fees of $ 66.00 payable to Butte County Treasurer. Impact fees paid. California Department of -Forestry plan approval/fees. Flood elevation letter (100 year flood) by California Engineer. Sanitation and plot plan approval Health Department.' City of C::ico plumbing permit. Plot plan and business, license approval from City of Biggs/Gridley. Planning approval for Land Development (a) Improvements (b) Drainage. Driveway permit (approval of construction required prior to occupancy). Contractor's license information (.No. Name Style, Class) or exemption statement. ,_ertificate of-.or;^rans Compensation Insurance. X Owner -Builder Verification Form. Recorded copy of rigricultural Acknowledgement Statement. Letter of signature authorization. Copy of recorded deed of parcel creation and 60' right of way to a public road. Letter of intent on building use. Mobilehome utility clearance. Documentation of legal access. Documentation of 5011 subdivision developed or (a) Road improvements completed and (b) Parcel meets zoning area and frontage requirements. Existing violations/expired permits resolved. Plan check list data and revisions. sets of plans in accordance with changes marked in red. Other: Should you have any questions concerRing-the above, please contact ALICE MEFFORD of this office.. Y rs very tr ly, Mic ael C. Vlieira, C.B.O. MCV:ahb Manager, Building Inspection PRE -INSPECTION OWNER: DATE�"�/� LOCATION: `J(.JC6jSA" mi, � I�VtC'.61.C) VCS A. P. C��g'-�� -CSD CONTRACTOR: ZONING F j?-� -------------------- PRE-INSPECTION FOR: DATE TO INSPECTOR , -------------=-------------------•-_1 PERMIT HISTORY: NONE AS FOLLOWS: ! % DD l�f.f�i✓ 7 4�,, -' 07- )0'�t37 TYPE OF OCCUPANCY • FIELD - INFORMATION Aga BUILDING USAGE: TENNANT: 9 E:] OCCUPIED 0 HAS ELECTRIC FD HAS GAS Q HAS�'SANITATION FACILITIES 0 HEATED -COOLED OTHER COMMENTS: [-I PERSON CONTACTED ACTION RECOMMENDED: ISSUE OLD FOR OTHER: BY DATE r -PA" COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 'PERMIT NO. APPLICATION AND PERMIT qq _ -22moZ ASSESSOR PARCEL NUMBER 058-440-008 ZONING FR -10 BUILDING PERMIT OWNER JOSE HERCADO TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAIUNG ADDRESS 382 PRESDIO ST., SAMIJENTO CA 95838 CONTRACTOR'S NAME 014NER TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOVM Total Valuation Is LENDER'S MAILING ADDRESS Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER LICENSE No. Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS SW CO2, STONE MOTINTAIN ED & CONCON 1d), PERMIT FEE $ PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 1 �' W Solar or heat pump water heater 23.00 LOT NO. SUBDIVISION'S NAME PARCEL MAP i piping P P 9 15.00 Each gas water heater or vent 15.00 USE OF STRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other ELE FOR WELL SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G I W @20.00 TYPE OF WORK New ❑ Addition ElRemodel ❑ Utilities ElInstallation ❑ Other Describe Work: PERMIT FEE g Contractor ELECTRICAL PERMIT Filing Fee 20.00 i Main Service ( 000V OR LESS ) fl 2 00A OLESS 23 .00 23.00 Main Service ( 200A TO 1000A ) 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( & ACC. SLOS. ) 3.50 FST,D. CONTRACTORS LICENSE LAW declare under penalty of perjury (check one) ❑ 1 am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) O I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) ❑ I am exempt under Sec. Business and Professions Code forthis reasonPRE—INSPECTION NEW CONST. MULTI -OUTLET •NON.RESID. ( BRANCH CIRCUITS ) @7.50 / POW ER APPARATUS ) 1 6 SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 @ 1.00 BAL. .50 FIXED APPLNS. OR EX. Occup. ( OUTLETS (RESID.) EA. ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE eclare under penalty of perjury (check one): O This permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a ertificate of Consent to Self -insure. I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 66.00 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against Said Cou in consequence of the grantin of this permit. X "" �' Date a re of Applicant - O%vner ❑ Contractor ❑ Agent A SHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST. TYPE TOTAL FEES 66.00 HAZ. 1 0. FEES IMP I FLOOD CDF PARCEL PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. BY Date PERMIT EXPIRES ON (Date) Receipt No. l� WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT _ w4er ,�� TRITuuo""'LANC, = C TRI TOOL INTERNATIONAL INC. TRI TOOL SERVICES. INC. *k _ 3806 SECURITY PARK DRIVE RANCHO CORDOVA. CA 95742.6990 (800) 345 5015 (916) 351 0144 TELEX 377.364 (PAX) 351 0372 1 � 7 ®ATI: /Q NO. OF RAGES: (Including this page) r COMPANY:_ D e p7; o4 of V, ,. T URGENT CONFIDENTIAL TELEPHONE ! FAX: S 3,P a1 VO ORIGINATORIDEP.` ' i PENT: SUBJECT: � MESSAGE: >q v c( %U o S nuc 1 I 0 u LC4 7 /'U,)& To A,9 r/ i -fes c� i✓v �_ .e �' 7-A \S 6 f-'1) F K>tivLj bi F- 7o ac a TO 39Vd_��_ � �; i01 IJl Z/EO—T9C-9T6 L.9 :9G t,66T/6T/6T ' JITNTY O I#UTTE - DEPAR TNZNT OF DEVELOPMENT SERVICES, BUILDING DIVISION #: 7 count =_y1 y Center Drive, oroville CA 9S96s Phone 916-538-7541 JOSE MERCADO 3824 PRESIDIO ST. SACRAMENTO, CA 95838 _ RE: APPLICATION FOR ELECTRIC SERVICE DATE A . P . 0 058-440-008 :�-- With reference to the above subject: Attached is: Application for permit Building Plans Mobilehome Utilities Installation Sheet Engineered Calculations Mobilehome Installation Information Sheet =Owner-Suilder if-ification Fm TYPlcal Plan Sheet List of Codes Enforced we need the following information prior to permit processing and/or issuance: P®"<<'it applic.aticn,sigrad and Completed where indicated with x,11 Copies returned. Plot plans, 3/4 sets, signed b Complete plans, 3/4 sets, signed nep db rey plans, pie f r Engineered plans and talcs, 3/4 sets, withwetsignature on plans, _ Hazardous Material Form Energy Design Compliance and supporting documentation. Statement of Intent for Non -Heated and A/C Buildings. Engineered truss details and layout in duplicate. =Mobilehome data and manufacturer's installation instructions, Pees of $ payable to Butte County Treasurer. 2 sets. Impact fees paid. California Department of Forestry plan approval/fees. Flood elevation letter (100 year flood) by California Engineer, Sanitation and plot pian approval City of Chico plumbin Health Department. Plot plan and business license approval from City of Bi Planning approval for ggs/Gridley. Lard Development (a) Improvements (b) Drainage. ^=iveway permit (approval of construction re ired prioto occupancy. Contractor's license information. (No. Name Style, Class) or exemption)statement, =pertificate Of :tior:c-^;ans Compenser-ion Insurance. Owner -Builder Verification Form. Recorded copy Agric::ltural Acknowledgement —Letter of signature authorization. Statement. Copy of recorded deed of parcel creation and 60' right of way to a public road. Letter of intent on building use. Mobilehome Utility clearance, Documentation of legal access. - -Documentation Documentation of 50V subdivision developed or (a) Road improvements completed and (b) Parcel meets zoning area and frontage requirements. Existing violations/expired permits resolved. Plan check list data and revisions. 60tS of plans in accordance with changes marked in red. ,cher. nould you have any questions concerning the f this office. =v: ahb above, please contact ALICE `IEFFORD Y rs aver7yty, Mic aera, C.B.O. Man ger, Building Inspection a r © 39t7_d 6111 -1001 Idl ��ZLE©-TSC-9T6 L9;:90 b66T/6T/©T �*OI2IVId UYtIt1�iIU8 �23�IV1132 TKMf,90J3V3f340 TYAXM'TAAg3Q - Mus 90 YTYIiI F 88289 A7 4iilvcmO -OVIIC 101aaa vanuoJ t*2r-ate-ate sonodq OQADIM 320t ,T2 OIC223s1q 0' & 8CBee h0 'OTY1aWOR =3TAQ�IVs�32 �IS1T3,I:3 A0� .i�.GI?A�I.I"?gA :3R 800_0+ -8eo 0 .9 . A �39Cd:�e' svode 914.1 a.1 5.1n919101 dJIW ' tEi b9t�Jby?l1 eart2 nQ�� tt16�8RZ 8!li.1�f27U smoctsfidoM._ .1im7eq lot noiisnIIq}A__„ sn�+i9 Etiibiiu8 . ]9s�i2 c�o'.�bmza3ni nni.1aS:io.1enl gmotisLidcsM,�,_,_ endii8lu3ta7 basfl9ntpn3 i .198142 naf4 teotq�`I' b9a�otn8 esbo� 30 381.1 _ mei noi.16sr3.. 'x.161tt: -zanwO - 93nscteex zcs`bns ptsise90oXq Sim 9g ci Yo27q notzamYotni enlwoil9Y e+i3 bash 3w b3rtzu:g': z9sgo3 fts 143!w b�3e3.i)?.'si 3 5ik bsrc.tq�`c3 b� nbsaExexs2i�l �ran4tq rCfqleq _ .enLiq 10 z9xsgsiq yd- E. «2natq 30 jgjsgoxq Yd b3:spiz ,a.1�+s AEMg . ens.tq no OWIznpiE .1sw K71W •.173.1 8 iM,101 ntb� 9saMbt3uo xaxnli� _noi.1aynszsu3ob. Ent.Izoqk ,A bzs sznzllgmcO npiesti Ygi9n3 ,8gnjbTIu9 D\A bm baJeOH-SOM 101 in inI to 3nsms3alZ 018011qub n4 7uoyel bna 81ia3ab eeuli bsissn1pn3 2.19a s .atcory�u=7ett1 nok uiisssc:i a `.791UZ003un" bn8 slob 9modol'doM­ .�9xuaegzT �(�nuo7 a s�u8 oy sidaXaq n---.�«-- 2 10 ae9S y :btaq east 7OagmI_ .0gg1\16voxgq5 nsiq y=.1es7oa to vism-I3agsct srn,102116D .YesntEnS sknxo3;ita:) ,jd (booi' 76ey 001) 15120: '13:1sv919 boo"- «at�gmyzsg9Q d.1i89H tavO qQA nafq yaiq tM5 nota[t33na2 .11mzoq vnttimuiq ooifm to Y210_ .y9Ibi7O\zV?,a 30 Y3i ma�3 I5vo7gge sasezij uesnIzavoud bna nsngnnatq, . epa:t: �s7n. S e3ns1n9volgml� ta} myCf9v9C t�ortsqua�o 01 101Iq he7lupoI noi 3 m+u7 I?noo 10 l evozggs) 3 imxaq yCt9tfs938j2 nat.1gmsxs za +a$ai� 9Ivja 9msOi .601) . SI., mYo3n"i eanaoil 8,1013allno!) . o3nazuans nr,_.. r:snhgttsc.r a^$.^port :o ,fIvA roijs3iiiz9v lgb!iu@-:9nwG__z_ 3;;stTgpf.`.slwan$MA " igcz bs.b7ol9n.....,.,- ..noi.1e�sizori3as s7u.1scsp.:s "to z973s.i baoi Iilduq'b a: xf5w 30 .1rigiz .`Oa bns noi.1gg'r3 ls3Zsq to b5 -5b b5b7o39x 310 VgOO e8t+ VnIbltud no Ina:n i to 29:15a . �onaYa9ta •.v9# t1�v 9MCsAaf idnM .8e9oo$ ,Ep*r.+i 3o t3C?.f38JCsamu3aL,�- �igmo9 e7n9mauo7q.tz kaQA (b) Yo b9golev9b bna bsjno-zivibdus i�4 3� nat3r:3romu�oa_,__ .a.1nameYzu89z ags.1no73 bna *ale gninos eaeam 10.3!4q (d) .b.vjoG*j allmiaq bsxigxs\snaiJsfgiv 2013aix3 . enoiei.vei bna b3ab 381.E A0043 nBSq,� bet n! ba$lzm 009nad3 MJIw 93nabYa3oa ni .2as`q tc;b3oa :Y9ri� a -------------- C3R0'�'3�!.30I.IA .1:,e;nco saeafq .�vodb sti3 pntn•sa3noo ar.Os�$9ug xnb sVed e333ia e�ri�or zy yJav 87 Y .O s:a ,57191 t9b nc�i339getti �,nibEiuB ,xDLO O&M NOTES . RESIDENTIAL 058440-008 99-1894 sPERMIT,NO. _--BAKER, ROBERT & PATRICIA-- -- - ,Ys4QSTOvIOUNTAIN DRIVE, ORO CONTR: ll&DHOMES MH ON PERM FND, NEW S THE HCD FORM 433A FOR THIS MH CANNOT BE RECORDED UNTIL ONE OF THE FOLLOWING HAVE BEEN TURNED IN TO THE BLDG DIV: k1) LICENSE PLATES) or DECALkTHE INSPECTOR MUST RETRIEVE) k2) STATEMENT OF FACTSkONLY ON NEW MH'S) INSPEQjQR TO VERIFY SERIAL & LABEL #'S SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER OFFICE COPY Address GAS Meter By Dat � I ELECT Meter B Date JOB FINALED (Date Signature ' V=OK 0 = Not OK - = Not Applicable = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. 1. Zoning Requirements -Setbacks -Easements Footings; Size -Spacing -Marriage Line Ext.; Steps -Doors -Landings Soils: Special MH Support Sketch 1,o-4! Electricity; MH Test -Crossovers -Breakers -Clearances 5. ewer; Location -Test -Fall -C/O -Concrete 6. 4_ e -r, Location -Test- Easement Needed (Sketch) Water and Sewer Connected -C/O to Grade -HD Approval 5. icity; Location-Clearances-Grnd•/ /Amp -Concrete 9. 6.� as; Location -Test -Wrap;-/ ,' /" L'ft. / P Nat. or / /"L"ft.�)/'LPG Exits; Insp.-Sketch 7. Well Clearance 8 Discohnec 12. 8. Utility Clearance Date / - Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOB&"OME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line Ext.; Steps -Doors -Landings Gas; MH Test -Demand -Valve -Connector 1,o-4! Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Fou dation Only; License Decal Date -/ a- Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 19 01-7 735cl,2 MISCELLANEOUS Date DECKS, COVER ,, CARPORTS GARAGES (Plans) OK except #'s oning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs.-Connectors Shthg.-Frg-Bracing { 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports: Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses i 9. Siding; Nailing -Veneer -Stucco -Mesh j 10. Roof; Shthg-Roofing w 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ;Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed ` 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater j 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. }) Boxes- Enclosures- Pane lboards-Ins. to Main in Conduit 9. Health Department Approval l' 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 ./= OK 0 = Not OK - = Not Applicable = Not Ready RESIDENTIAL (; Date Hangers -Post Caps -Anchors -Connectors Underfloor (Plans) OK except #_s Cling. Joist-Rftr. Ties-Purlin-Roff Brac.-Truss-Shting.-Rfng. 1. Zoning -Setbacks -Easements -Flood -Slope " 49. 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 52. 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 5. Stemwalls, Main; Steel-Blockouts-Wrapped 55. 6. Stemwalls, Garage; Steel- Blockouts-Wrapped Siding -Nailing Veneer 6a. Hold Downs and Special Anchors 58. 7. Slab, Steel -Wrapped Shear Walls; Nailing -Bolts 8. Piers -Fireplace Ftg.-Steel 61. 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Infiltration -Walls -Windows 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Gas Test -Meters Tagged, Gas -Electric 11. Water Pipe; Test -Anchors -Regulator -Service Test Water & Sewer Connected -C/O to Grade -HD Approval 12. Electric Underground Energy Compliance Certificate -Other Certificates 13. Plenums & Ducts; Clearance -Material -Support -Ins. Address Posted 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation Card B-1 Date Card B-1 16. Insulation Card B-1 Date Card B-1 Date Date Comments at Final: Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip. Ground made up w/Mach Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or M-A.C. Wire Size / / ga Cu or AI 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or Al Insulated Neutral O Yes O No 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35. A.C. Ducts Insulation & Support 36. Vent Fan, Exhaust above insulation 37. Condensate Drain & Overflow, Size & Grade 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 39. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) • Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roff Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 82. Following Instld./Drive :) Yes ] No/Walks J Yes ❑ No/Planters Q Yes D No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: �3.*'„i•'-�„�'�fl;�'t•'�;„'�-�.,..-'^fir-- - »�-�...-� :+"`_.=t'.'-:,,^-+:.. -. �.�,,:-,:,*..�� COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • ('530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 r 1 CORRECTION NOTICE 6WNER Y# PERMIT A routine inspect ion indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. f / r Ti!�- Y /2'L4,o t O1 / ! _ 1- �- , or w� Y y, -ik Date Inspector REV 10/,92 ' F a COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVI 411 Main Street - Chico, CA * (530)'891-2751 7 County Center Drive - Orovill�, CA • (539) 538-7541 CORRECTIONNOTICES 'ZI OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please, contact this office immediately. Z 7} Date - Inspector REV 10/92 ��� �3) �°'°D RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 29 -Nov -1999 1999-0049602 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ROBERT J. BAKER & PATRICIA A. BAKER BUTTE COUNTY BUILDING DIVISION REAL PROPERTY OWNER (LESSOR LOCAL AGENCY ISSUING PERMIr and CERTIFICATE OF OCCUPANCY 2151 GRAND AVENUE 7 COUNTY CENTER DRIVE MAILING ADDRESS MAILING ADDRESS OROVILLE, BUTTE, CA 95965 OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP CITY COUNTY STATE zip 3540 STONE MOUNTRAIN ROAD 99-1894 (530)538-7541 INSTALLATION MAILING ADDRESS, IF DIFFERENT BUILDPE TELEPHONE NUMBER OROVILLE, BUTTE, CA 95965 ; 11/29/99 CITY COUNTY STATE ZIP SIGNATURE OF LOCAL AGE?ZT5FCLAL DATE SAME NONE UNIT OWNER (if also property owner, write •SAME') DEALER NAME Cifnot a dealer sale, write'NONE') MAILING ADDRESS DEALER LICENSE NO. em coor+rr suis Z2 UNIT DESCRIPTION FLEETWOOD 1997 SUNCREST MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAME/NUMBER _OAELV17A/B20293SC12 44'X 24' RAD1010685/6 SERIAL NUMBER(S) LENGTH X WIDTH INSIGNWLABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER A.P. #058440-008 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE - County Recorder CANARY - HCD PINK - Appfieant GOLDENROD- Balding Dept 14 BUILDING PERMIT NUMBER: 99-1894 Address or location of unit: 3540 STONE MOUNTRAIN ROAD, OROVILLE, CA 95965 Legal Description of Real Property: A.P. #058-440-008 SEE ATTACHED t (x) Mobilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: ROBERT J. & PATRICIA A. BAKER Owner's address: 2151 GRAND AVE., OROVILLE, CA 95965 INSIGNIA OR HUD NUMBER: RAD1010685/6 SERIAL NUMBER OR V.I.N.: CAFLVI7A/B20293SC12 ' MANUFACTURER'S NAME: FLEETWOOD YEAR: 1997 OFFICIAL APPROVING INSTALLATION: DATE: 11/29/99 PHONE: (530) 538-7541 9 H.C.D. 513C , 2 LEGAL DESCRIPTION A.P. #058-440-008 All that certain real property situate in the County of Butte, State of California, described as follows: Parcel One: Parcel 1, as shown on that certain Parcel Map, filed in the Office of the Recorder of the County of Butte, State of California, on March 6, 1972 in book 41 of Maps, at Page(s) 43. Parcel Two: Being a portion of the L. Ferro Tract as shown on that certain Record of Survey map of Section 21, Township 22 North, Range 4 East, M.D.B. & M., as recorded May 14, 1968 in book 33 of maps at page 37, and being more particularly described as follows: A non-exclusive easement for road and public utility purposes over strip of land 60.00 feet in width lying 30.00 feet on each side of the following described centerline: Beginning at the Northeast corner of that certain parcel of land conveyed in deed to Wm. R. Tindle, et ux recorded in book 1520 at page 563, Butte County Official Records and being as shown on that certain record of survey of a portion of the East half of Section 21, Township 22 North, Range 4 East, M.D.B. & M. For David W. Harper, et al which map was filed in the office of the Recorder of Butte County, in book 33 of maps at page 46; thence following along the Northerly boundary line of said Tindle parcel, North 79 deg. 20'58" west for a distance of 68.15 feet thence following along the arc of a 550.00 foot radius curve concave to the Northeast, Southerly through a central angle of 7 deg. 55'52" for an arc distance of 76.13 feet to the beginning of a 450.00 foot radius curve to the right; thence following along the arc of said curve to. the right through a central angle of 3 deg. 22'44" for an arc distance of 26.54 feet to a point therein, said point being the true point of beginning for the centerline herein described; thence South 55 deg. 45'44" West for 36/08 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 45 deg. 34'52" for an arc distance of 79.55 feet to the end of said curve; thence South 10 deg. 10'52" West for 213.78 feet to the beginning of a 300.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 11 deg. 1710" for an arc distance of 59.09 feet to the end of said curve; thence South 1 deg. 06'18" East for 236.19 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through as central angle of 176 deg. 02'56" for an arc distance of 307.26 feet to the end of said curve; thence North 5 deg. 03'22" west for 247.14 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 59 deg. 23'57" for an arc distance of 103.67 feet to the end of said curve; thence North 64 deg. 26'37" West 64.25 feet to the beginning of a 200.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 22 deg. 16'28" for an arc distance of 77.75 feet to the end of said curve; thence North 42 deg. 10'09" West for 139.04 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the Page 2 Legal Description AP # 058-440-008 arc of said curve to the left through a central angle of 25 deg. 38'48" for an arc distance of 44.76 feet to the end of said curve; thence North 67 deg. 48'57" West for 186.17 feet to the beginning of 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 22 deg. 39'30" for an arc distance of 39.50 feet to the end of said curve; thence North 45 deg. 09'27" West for 35.09 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 23 deg. 36'40" for an arc distance of 41.21 feet to the end of said curve; thence North 68 deg. 460711 West for an arc distance of 140.00 feet to the beginning of a 300.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 4 deg. 46'04" for an arc distance of 24.96 feet to the end of said curve; thence North 73 deg. 32'11" West for 39.91 feet to the beginning of a 200.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 19 deg. 2720" for an arc distance of 67.91 feet to the end of said curve; thence South 87 deg. 00'29" West for a distance of 103.72 feet to the end of said centerline, said road easement is to include 20.00 foot radius returns at the intersection with the Oroville-Concow Road. The boundaries of said easement are to be lengthened or shortened to meet the property lines involved. Said road easement is for the benefit of and appurtenant to the lands of the grantees herein and shall inure to the benefits of and may be used by all persons who may hereafter become the owner of said appurtenant property of parts or portion thereof. M 11/29/99 10:06 FAX 530 532 3304 D.& D HOMES ®002 TV STATE OF CALIFORNIA NUMBER: BUSINESS. TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT •) DIVISION OF CODES AND STANDARDS - MANUFACTURED HOUSING PROGRAM MANUFACTURER CERTIFICATE OF' ORIGIN HCO 483.0 -Side 1 - (5195) - • • _ - _.. .. . • - _ K ❑ CHECK IF THIS IS A DUPLICATE MCO ENTER ORIGINAL MCO NO. MANUF-AGTURED •HOMEIMOB ILEFK= xUSF,D'(SJNGLE FAMILY DWELLING) D MFD (MULTIPLE FAMILY DWELLING) NUMBER OF TRANSPORTABLE SECTIONS 2 .. .. 's• .. '- :;� .. C.OMMERCIALCOACH: OCCUPANCY GROUP MANUFACTURER NAME: 'MANUFACTUREUICENSE NUMBER: Fleetwood Homes, Inc. 9534 �6CAU r MANUFACTURER ADDRESS: SUGGESTED RETAIL PRICE: P.O. Box 1308, �. wood! d . Ca. 7 :: `� ,� � � •,,.;��;.� ,-- s L NAME ANMR NUMBER: DATE OF MANUFACTURER: .'Suncrest 344-2K 8-26-97 NAME OF DEALER OWNERSHIP TRANSFERRED TO: DEALER NUMBER: DATE OF TRANSFER: H i• D' HCAIes .-1.373() •8-29-97 `a DEALER ADDRESS: 224 3 Feather River --�6lvd..-- .Oroville Ca. _ ..9 5965 slree State INVENTORY CREDITOR NAME: Green -Trees-Fisianc al.=.-Attax: hccounts 'Payable INVENTORY CREDTTOR- P` ''J`5570 Santa Aiiar ' Ca:I' 927995570 tree (01y) State ' SECTION- _ : LENGTH ' W DJ H• 1NEIlwF - ' 1.8 MANUFACTURER SERIAL NUMBER NCO tMSIGNtA OR Iwo LABEL NUMBER ' INCHE ' INCHES (POUNDS) :i/�..i' �+�-'��av!l�f�� /�.il.f.:t ' 1.:.• 1�... �%��._!I��.i.../q�.I -s�C, I is TRANSPORTER NAME TRANSPOWER DECAL NUMBER Mobile Hage. Service .. ,�. 115192 � TRANSPORTERAOORE88:,: P.O. Box 1'19 Durham, Ca 5939 SIM ' I Cal* unser penalty of p"wdet Ike Usti at Ma SIM x Ceft ma !flet the Zeal, fees &C We ft -4 Wff6a . t- Emotedon ac Woodland, Yolo, California (Ogle) !C' Mauro) S16"RE OF AVTNOAt;EO AOENTT ' A6j=gVTION: ORIGINAL (PINK) FO TO THE WVENTORY CRIOROO, URfEB' xAstE IS NONE. THER FORwAROTO THE PURCWLSER COPY 1 (VAgw) FORV"D TO THE DEPARTMENI AT P.O. BOX 1018. SACRAMENTO. CA 95812AMB• WITHIN FIVE (6) DAYS OF RELEASE. COPY 2 (YELLOW) OELIVER TO THE TTRRAN PORTER TO ACCOMPANY THE UNIT TO ITS DESTINATION. COPY 9 (GOLAENROD TO BE RETAINED BY:TNE MANUFACTURER HCO 483.0 -Side 1 - (5195) - • • _ - _.. .. . • - _ K STATE OF CALIFORNIA�N� B1. :�5, TRANSPORTATION AND HOUSING AGENCY : _i'1UkTMENT OF HOUSING AND COMMUNITY DEVELOPMENT DMSION OF CODES AND STANDARDSs REGISTRATION AND TITLING PROGRAM "h -4 STATEMENT OF FACTS This unit is a: ® Mobilehome 0 Commercial Coach 0 Floating Home El Truck Camper Decal (License) No.(s) Trade Name -Fie.��O j I/We, the undersigned, hereby state: Serial No. -(s) THE ABOVE DESCRIBED MOBILE I•IOME HAS BEEN INSTALLED ON AN APPROVED PERMANENT•FOUNDATION SYSTEM AND IS PRESENTLY IN ESCROW WHICH WILL CLOSE WITIiIN 45 DAYS. I/We further agree to indemnify and save harmless the Director of IIousing and Community Development, State of California, and subsequent purchasers of said.unit, for any loss they may suffer resulting from registration of the above-described unit in California, or from issuance of a California certificate of title covering the same. I/We certify under pena►ty of perjury that the foregoing► is true and correct. Executed on )? / ( 4 (bate) Signature(s) oJiC_Lir" (City) - Printed namc(s) C7" 1 lgr (State) Address AP -0 ©-'5_?" T g 00 4nS City , State. HCD 476.6 (P F" RECORDING REQUESTED BY:, Fidelity National Title of California Escrow No. 100979•JC Title Order No. 00100979 When Recorded Mail Document and Tax Statement To: Mr. and Mrs. Robert J. Baker 2151 Grand Ave. Oroville. CA 95965 1 999-92)lG26884B Recorded Official Records I REC FEE I TAX 10.00 County Of 1 14.85 CANDACEUJTEGRUBBS j ROSEMARYrder DICKSON j Assistant 11:56PM 21 -Jun -1999 I Maureen I Fuge 1 of 2 GRANT DEED SPACE ABOVE THIS LINE FOR RECOROEFVS USE The undersigned grantor(s) declare(s) Documentary transfer tax is $14.85 I X I computed on full value of property conveyeJ, or ( ) computed on full value less value of liens or encumbrances remaining at time of sale, I X ) Unincorporated Area City of FOR A VALUABLE CONSIDERATION. recoipt of which is hereby acknowledged, Jose Mercado an unmarried man and Linda Mercado, An Unmarried Woman who acquired titleas Linda Lakin hereby GRANT(S) to kbd�dtl,1!/B'Akf fh6/F1a4rrldib/Al./0a(k/ef/ Robert J. Baker and Patricia A. Baker,husband and wife as joint the following described real Tenants roe p p rty in the County of Butte, State of G.alifornia SEE EXHIBIT ONE ATTACHED HERETO AND MADE A PART HEREOF PIEC- iK1, F'S INA NO: f( CORD 15 DUE TO DATED: June 75, 1999 (;lJAL!')'( OF Ob'!}.I.Ai ry'�1►1�tr_r.rr STATE OF CALIFORNIA COUNTY OF ON .... `/ before me, hvt%ersonall y appeared personally known to me (or proved to me On the basis of satisfactory evidence) to be the person(s) whose names) is/are subscribed to the within instrument and acknowledged to me that •h*Mhe/they executed the same in hlslher/their authorized cepacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the persons) acted, executed the instrument. Witness my hoed and official seal. Signature .JoseMereado v Linda Mercado LINDA L MEAD Commission If 1150982 -i Notary Public - California So=Vnento County FD -213 (Rev 7/96) MAIL TAX STATEMENTS AS DIRECTED ABOVE GRANT DEED `J 00979 -JC /o. 00100979 EXHIBIT ONE cel One: Parcel 1, as shown on that certain Parcel Map, filed in the Office of the Recorder of the County of Butte, State of California, on March 6, 1972 in book 41 of Maps, at Page(s) 43. Parcel Two: Being a portion of the L. Ferro Tract as shown on that certain Record of Survey map of Section 21, Township 22 North, Range 4 East, M. D. B. & M., as recorded May 14, 1968 in book 33 of maps at page 37, and being more particularly described as follows: A non exclusive easement for road and public utility purposes over strip of land 60.00 feet in width lying 30.00 feet on each side of the following described centerline: Beginning at the Northeast corner of that certain parcel of land conveyed in deed to Wm. R. Tindle, et ux recorded in book 1520 at page 563, Butte County Official Records and being as shown on that certain record of survey of a portion of the East half of Section 21, Township 22 North, Range 4 East, M. D. B. & M. for David W. Harper, et al which map was filed in the office of the Recorder of Butte County, California, in book 33 of maps at page 46; thence following along the Northerly boundary line of said Tindle parcel, North 790 20' 58" West for a distance of 68.15 feet thence following along the arc of a 550.00 foot radius curve concave to the Northeast, Southerly through a central angle of 71 55' 52" for an arc distance of 76.13 feet to the beginning of a 450.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 31 22' 44" for an arc distance of 26.54 feet to a point therein, said point being the true point of beginning for the centerline herein described; thence South 551 45' 44" West for 36.08 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 450 34' 52" for an arc distance of 79.55 feet to the end of said curve; thence South 101 10' 52" West for 213.78 feet to the beginning of a 300.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 11 ° 17' 10" for an arc distance of 59.09 feet to the end of said curve; thence South 1 ° 06' 18" East for 236.19 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through as central angle of 176° 02' 56" for an arc distance of 307.26 feet to the end of said curve; thence North 51 03' 22" West for 247.14 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 59023' 57" for an arc distance of 103.67 feet to the end of said curve; thence North 64° 26' 37" West 64.25 feet to the beginning of a 200.00 foot radius curve to the right ; thence following along the arc of said curve to the right through a central angle of 22° 16' 28" for an arc distance of 77.75 feet to the end of said curve; thence North 42 ° 10' 09" West for 139.04 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 251 38' 48" for ars arc distance of 44.76 feet to the end of said curve; thence North 670 48' 57" West for 186.17 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 22° 39' 30" for an arc distance of 39.50 feet to the end of said curve; thence North 450 09' 27" West for 35.09 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 231 36' 40" for an arc distance of 41.21 feet to the end of said curve; thence North 681 46' 07" West for an arc distance of 140.00 feet to the beginning of a 3.00.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 40 46' 04" for an arc distance of 24.96 feet to the end of said curve; thence North 73° 32' 11" West for 39.91 feet to the beginning of a 200.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 190 27' 20" for an arc distance of 67.91 feet to the end of said curve; thence South 870 00' 29" West for a distance of ,103.72 feet to the end of said centerline, said road easement is to include 20.00 foot radius l efurns at the intersection .with the Oroville-Concow Road. The boundaries of said easement are to be lengthened or shortened to meet the property lines involved. Said road easement is for the benefit of and appurtenant to the lands of the grantees herein and shall inure to the benefit of and may be used by all persons who may hereafter become the owner of said appurtenant property of parts or portion thereof. _4k COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 61 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 9% '-AMNO. (Rev. APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER ROBERT TELEPHONE SO. FT. OCC: BUILDING VALUATION 1034 R 55,836 .OWNER'S MAILING ADDRESS 9151 CRANI) AVENITE, OROVILLE, 9596 '-L'-- CONTRACTOR'S NAME D AND HOMES TELEPHONE CONTRACTORS MAILING ADDRESS 994'1 FFAIHER RIVER T CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 143.49 BUILDING ADDRESS Energy Plan Checking Fee $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PAR L jAAP !/ PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome PC Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Unities ❑ Installation ❑ Other &Y Describe Work: MN/PERM FDN Gas piping stem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home ISI GI W @20.00 PERMIT FEE S 65.00 ELECTRICAL PERMIT Filing Fee 20.00 OOOVR LESS Main Service .0A OR LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my licenseJJ's�, In f i rCe and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor .Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My worked' co pe tion insafance carrier and policy number are: Carrier �► z!4ne -fiJ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if should become subject to the works s' comp ns ' n visions of section 3700 of the Labor Code, I shall fortth comply w th s , provisions. X ( Date 14717 Signaturg of Applica ❑ Owner ❑ Contractor ❑ Age An OSHA permit is re ired for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. DWEwNG OCCUP. SO OR ADDNS. ( a ACC. S.3.50FT, 1t p°�I.T MUL 11 UTLET 97.50 POWER APPARATUS a SINGLE ounEr dR. @ 1 00 EX. OCCU OUTLET OR FIXTURES 620 .FIX50 UNS Ex. Occup.OUT>�rTS (RR.,6.)OFR.a 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 63 ..00 MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee Is Energy Inspection Fee $ occ CONST. TYPE TOT FE 12 4 + ' D. FEES I FLoo CDF p HD S This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have BJPLkX­6/.te PERM T EXPIRES ON the app(cable provisions Resolutions to do work been paid. Date Receipt No. WHITE-D.D.S.-B.D. CANARY -ASS OR NK -INSPECTOR GOLDENROD -APPLICANT ,�,'y`�,-,.� .�+t''. j'rj`�"'�r'';j'ae "�T�j:',,s{)'J�`+Za aM�'...i�.;i...w��G:.h:.,.h"ti0"S.r7f"it+-t�'�...,,44.Y+X•sj•`�,SES;.�Y'`r`+`""1"`.t.:1't°''�'"• . ICOUNTk OF BUTTE - DEPARtTMENTF Q VELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE;,CALIFORNIA 95965 - TELEPHONE (530) 538-7541: PERMIT.APPLICATION DATA SHEET OWNER: k f"p- R a ASSESSOR PARCEL NUMBER: © O P, Proposed Building Use: (d,, �Z fo,)Building Inspector: %% Date:f At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By 111. All iiems have been submitted -------------------------------------------------------------------------------------- 132. Plot plans, 3/4.sets, signed by the preparer of plans. ------------------------------------------------------------ ❑3. Complete plans, 3/4 sets, signed by the preparer of plans. ----------------------------------------------------- ❑4. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ ❑ 6. Energy Design Compliance and supporting documentation.---------------------------------------------------- „ ❑ 7. Statement of Intent for Non -Heated and'A/C Buildings. ---- ❑ 8. Hazardous Material Form. ❑ 9. Manufactured Home data and installation instructions including Tie Down Specifications .------------------ . A10. ges of $------=------------------------------------------------------------------------------ yy 1. pact fees as shown on the attached schedule. ---------------------------- ------------------------- C - -- California Department of Forestry plan approval/fees. -- ------------------ lood elevation certificate. --------------------------------------------- �<Vsanitation and plot plan approval _ Health Department. ❑ 15. City of Chico plumbing permit.--------------------------------------- E116. -------------------------------------- ❑ 16. lot plan and business license approval from the City of Biggs. ---------------------- ❑ . P anning approval for (A) Use: -/ (B) Parking: - Contact Land Development about Improvements, ❑ Drainage, 16 Legal Parcel. ❑ 19. Encroachment Permit for driveway (construction approval prior to occupancy). ---• ❑20. Pre -inspection for required Request to Building Inspector on 021. Contractor's license information. (Number, Name Style, Classification). El 22. Workers' Compensation carrier and policy number. ----------------------- ❑23.Owner- Builder Verification (Given to owner 11, Mailed to owner ❑). - 02 er of signature authorization. ---------------I----------------------------- 5 Recorded copy of Agricultural Acknowledgment Statement. -------------- El 26. Letter of intent on building use.----------------------------------------------------------------------------------- ❑ anufactured Home utility clearance. ----- --- -------------------------------------------------------------- 28 , sting viol ' d/or eepired permi -------------------------------------------------------------------- 2 . ❑433 A, �[h►�Title, Check to H.C.D $ ZZ . --------------- 30. Other: ------- When you issue the permit, process as follows ❑ Mail to owner, ❑Mail to contractor. ALelephone-S3' 2- ;33 O / and hold for pickup at 0A_Z.> L k. i Applicant: Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: r with inspector. Date: By: Date: By: 1. Index permit application for the above items numbered:4V2 ❑ Plan Check List 2. Additional items required: % Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by ❑;phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by. -.b phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by o,phone, ❑ mail, ❑uildin uis�io counter, by Date: Plans reviewed by: Date: �� Plans approved by: Date: • � — ., Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folde`; "t`�.'' ;,:Note transfer by: Date: Yellow Copy - Department of Development Services, Building -Division. E.H. USE ONLY Rot Pion Attached ✓ Floor Ran Anschod�— Sent to B.O. TO: Building Department ��. FROM: Environmental Health SUBJECT: Sanitation Clearance yyv-ate Owner Location AP# Plan Approved for: Sewage Disposal j-� Water Su ply: Public Private Well Clearance for dwelling. Other Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist Date 8/96 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 j L SCHEDULE OF FEES DUE OWNER I�. �� fJ�/C�y A.P. # C>S—,' ' y�L-6 —c� U S On n ' ,,/� PROPOSED BUILDING USE m!K Al --zJ .51 � . DATE 1. BUILDING PERMIT, FEES -- Balance Due ................ $ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee ....... $ tL SCHOOL DISTRICT FEES D� f'� •� (paidat istrict Office) SHE FEES (paid at Building Division) !1 '00 Residential ........ �_ x $360.00 Units Commercial (sq.ft.)... x $0.03 = $ Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x : = $ #units Amt. Commercial (sq.ft.) .. x =$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES $510.0 (paid at Building Division) SRA FIRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER RECEIPT # DATE REC i At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit These fees may be changed durin& the p* checking process. APPLICANT Pursuant to Government Code Se ion 6602 project. You have 90 days from khe date protest. The requirements for a pro are Original -Building Div. 2nd Copy - Applicant / q -' DATE you are hereby notified that items 2,3,4,5,6,8,9, and 10 above y have been imposed on your approval of the project or from the imposition of the above mentioned items during which you may specified in Government Code Section 66020(a). 3rd Copy - Owner (Rev. 2/97) :N `r\� .'t'.��....*�..,. rx .,: ih•%t`ahs...,wlir�°'..rK1rx'��i=`'gy.,«�yL,,-•, „ 7i .•a2` `. iii Ile?�F Y.t4%wdKtA'�►'r t'+.-'3 ".,^,�. .7r - �•..,. - - .-e r., TM.=r F po3,,e' 14 BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building)p . School District' �r� �I X— 1--��� Building Department No. A.P. Number (—,1/1&—&V9risdiction: X City County Property Owner Q r(ri_Y Property Location/Address Subdivision Lot No. . Residential Development FTJ .....:......................................................................:....................................... LJ Sq. Footage t�3L No of Living Mobile Home Addition/ 'Supplemental to (Group ) Units Installation Conversion Permit # *(No foundation inspection): ................................................................................................................... Commercial/Industrial Sq. Footage New Addition (Including Exterior Roofed Areas) Buil ing Department epresent,4Nve Date moor vans revievveo oy acnooi District Identification No. 000043 Orovi-1141n... UhCQ n School District certifies tha (Street Address) am 14e, Jisned (City) has complied with the requirements of Resolution No. representing D" " square feet. S67oor5istriat Reoresentative_ I' Paid by Check # Remarks: ursinct rersonneU (State) � Mr (Phone Number) (Zip Code) by payment of $ �"1��► 6�.+d� AB 2926 $ FULL MITIGATION $ l I _ I eury .d .-s l i 10-T-1,01 Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with' Government Code Section 66020(x), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the,School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agencyithat this project is being reviewed under the California Environmental Quality Act (CEQA), i this project may be subject to additional school fees to fully mitigate its impact on the school district's schools: White (applicant), Yellow (building department), Pink (school district) feeform.xis I10i9e)drnm COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 11 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 "_ jIf NO 196) 6) APPLICATION AND PERMIT ASSESSORPARCELNU►eEN ons _ o © 6 ZONM �&-,e /p BUILDING PERMIT °N'"ER TVLEPHONZ SO• FT. OCC. BUILDING VALUATION OWNERS MARM ADORES S .2-i s l U COMRACfOR'S lyA1! c • e�vca.,� TCU9110NE -54W 33oI CONTRACTOA MAUNO AO Z e � / —� I/ CONSTRUCTION LENDER LENDER*$ MNUNG ADDRESS Fireplace Total Valuation S ARCHITECT OR ENOINE61 LICENSE NO. Rlinq Fee $ 20.00 ARCHITECT OR ENGNEER S MA ING ADDRESS Permit Fee S 2 2 (D. Plan Checking Fee $ L n a,�orulAooaEss Energy Plan Checking Fee E $ PERMIT FEE _ „ 2 LOTNI/p w vsNswwE sueaa PARCEL. MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other sPEcsv Each Trap 7.00 Solar or heat pump water heater 23.00 i Water piping 15.00 Each ss water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Describe Work: Other ❑ Gas piping system t - 5 outlets 15.00 / j , o0 Building sower 15.00 /S ®o Mobile Home I S I G I W (g?20.00 i PERMIT FEE ELECTRICAL PERMIT Filing Fee 20.00 Main Service 2a.ow 001.1 LIEN, 23.00 2.3 0v ' n L/ (� t l V 0 L , /� L O I / 1 Cv VV Main Service 200A TO 1000A 48,00 NEWDNDWELLSO OR ADw+S. s. ( IJG a ACC. OLDS. 3.5¢FT: NtW . MULTI -OUTLET H CIRCUITS @7.50 NON.RESID. PGWER APPARATUS oUTtET FL 00 EX. OCCU OOR FIXTURES g� 0 I.SO MDA"INS MD Ex. Occup. FDCE5.00 R.,NS Eslo. OR EA. Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE 49M a d MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt: S Mobile Home Installation Fee S Energy Inspection Fee 5 occ coral. TTPE TOTAL FEES �z• D. FEES IMP :L000 COF PARCEL PO ND I ESUE 2, 237�9' This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By PERMIT EXPIRES ON Date And when recorded mail to: Building Division 117 County Carter Drive Orovillc, Ca..95965 COPY of Document Recorded 13 -Sep -1999 . 1999-0039039 Hag not been compared with original- BUTTE riginalBUTTE COUNTY RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEDCMRNT FOR RF,SIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjaccni to land or included within an arca zoned ror agricultural purposes, and residents of this property may be subject. to inconveniences or discomfort from the use or agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and front the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Bulle County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Bullc, State or California, (described as follows: S5 ed i dYs P't V C- 1 -4 �� ' 1 �' l)% /� �C..a f Dale: i-�_ PROPERTY OWNERS: State of California ) Countyof Oil `� t� `l `i berore tne, C' Uu rt ►,� _ LC; ,Z- personally appeared i (Z l (1 I Personally known to me to be the person(4 whose n:uuc(gish"subscribed to llie within instn►ntcut and acknowled-.1cd to site that he/she/ltu;} executed the same in kis/hcr/their authorized capacity(ics), and that by un the instrument, tits persou(,g or the entity upon behalf or which the person(syncted, . executed the instrument. '1 WITNESS my td :lid or 7., %,MY CYNTHIA A. COSTA D0COMM# 1103301 NOTARY PUBLIC -CALIFORNIA �Signature !�L- SFCOUNTY OF BUTTE w Comm. Expires Oct. 30, 2000 1 A.P.11 EXHIBIT "ONE" Parcel One: Order No. 100979 Parcel 1, as shown on that certain Parcel Map, filed in the Office of the Recorder of the County of Butte, State of California; on March 6, 1972 in book 41 of Maps, at Page(s) 43. Parcel Two: Being a portion of the L. Ferro Tract as shown on that certain Record of Survey map of Section 21, Township 22 North, Range 4 East, M. D. B. & M., as recorded May 14, 1968 in book 33 of maps at page 37, and being more particularly described as follows: A non exclusive easement for road and public utility purposes over strip of land 60.00 feet in width lying 30.00 feet on each side of the following described centerline: Beginning at the Northeast corner of that certain parcel of land conveyed in deed to Wm. R. Tindle, et ux recorded in book 1520 at page 563, Butte County Official Records and being as shown on that certain record of survey of a portion of the East half. of Section 21, Township 22 North, Range 4 East, M. D. B. & M. for David W. Harper, et al which map was filed in the office of the Recorder of Butte County, California, in book 33 of maps at page 46; thence following along the Northerly boundary line of said Tindle parcel, North 79 ° 20' 58" West for a distance of 68.15 feet thence following along the arc of a 550.00 foot radius curve concave to the Northeast, Southerly through a central angle of 70 55' 52" for an arc distance of 76.13 feet to the beginning of a 450.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 30 22' 44" for an arc distance of 26.54 feet to a point therein, said point being the true point of beginning for the centerline herein described; thence South 550 45' 44" West for 36.08 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 451 34' 52" for an arc distance of 79.55 feet to the end of said curve; thence South 100 10' 52" West for 213.78 feet to the beginning of a 300.00 foot radius curve to the right; thence following along'the arc of said curve to the right through a central angle of 11 ° 17' 10" for an arc distance of 59.09 feet to the end of said curve; thence South 1 ° 06' 18" East for 236.19 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the`right through as central angle of 1761 02' 56" for an arc distance of 307.26 feet to the end of said curve; thence North 5 003' 22" West for 247.14 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 59°23' 57" for an arc distance of 103.67 feet to the end of said curve; thence North 641 26' 37" West 64.25 feet to the beginning of a 200.00 foot radius curve to the right ; thence following along the arc of said curve to the right through a central angle of 220 16' 28" for an arc distance of 77.75 feet to the end of said curve; thence North 420 10' 09" West for 139.04 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 251 38' 48" for an arc distance of 44.76 feet to the end of said curve; thence North 670 48' 57" West for 186.17 feet to the beginning of a 100.00 foot radius curve to the right; thence following along the arc of said curve to the right through a central angle of 220 39' 30" for an arc distance of 39.50 feet to the end of said curve; thence North 450 09' 27" West for 35.09 feet to the beginning of a 100.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 230 36' 40" for an arc distance of 41.21 feet to the end of said curve; thence North 68° 46' 07" West for an arc distance of 140.00 feet to the beginning of a 300.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 40 46' 04" for an arc distance of 24.96 feet to the end of said curve; thence North 730 32' 11 " West for 39.91 feet to the beginning of a 200.00 foot radius curve to the left; thence following along the arc of said curve to the left through a central angle of 19 0 27' 20" for an arc distance of 67.91 feet to the end of said curve; Order No. 100979 thence South 87° 00' 29" West for a distance of 103.72 feet to the end of said centerline, said road easement is to include 20.00 foot radius returns at the intersection with the Oroville-Concow Road. The boundaries of said easement are to be lengthened or shortened to meet the property lines involved. Said road easement is for the benefit of and appurtenant to the lands of the grantees herein and shall inure to the benefit of and may be used by all persons who may hereafter become the owner of said appurtenant property of parts or portion thereof. Assessor's Parcel No: 058-440-008 9:)-a Z- - I - '�AT iZ 1 L j d1 63�1L�� BUILDING PERMIT i SITE PLAN CHECKLIST APN: C�'S8 �'�l O= DO Building Permit No.: - .�•� Proposed Use: SFD O MHO Res. Accessory U. Ag. Bldg. U Commercial O InduArW O Other: Zone District: �IZ 10 General Plan: A- A Z. The Proposed Use Is: Permitted: Not Permitted: Requires a Use Permit: Requires a Minor Use Permit: Requires an Administrative Permit: Accessory Bldg. Use: Parcel Created By Map? No: Yes: h Book/Page _ _ Map Conditions? No: Yes: . See reverse side Use Permit: Variance: Dev. Agreement:. Applicable Setback Zoning Code Streets & Hwy. Fire Prevention Subdivision Map Front Side - Side, street Rear Q 3 Height Parcel in Land Conservation Agreement? No: 2< Yes: , Check Use Parcel in North Chico Specific Plan? No: Yes: , he NCSP Zoning Parcel in Floodplain? No- -_----<- Yes: , Zone: Panel No.:e-- Parcel in Enterprise Zone? Yes: , Check Use CommerciaUIndustrial Uses Parking Requirements: OK as shown Other. Landscaping Requirements: OK as shown Other Comments: Reviewed By: Date: CHECK • • • WHICH • PARCEL./ RR PAID TO THE RURDING I UNLESS OTHERWISE N/ TED, —1. Submit a plan of the existing on-site mature trees, located in the proposed for building and driveway area prior to grading or t vegetation removal. Minimize the removal of mature trees, where possible. A mature tree shall be defined as'a tree with a trunk measuring 4 inches in diameter. 4 feet from ground level. Mature trees removed shall be replaced by planting replacement trees of equal number and not less than --gallon size. _2. Prior to' the commencement of grading and/or construction activity, all individual or groups of oak trees which ane to be I retained as part of the project, shall be fully protected through the use of root protection zones (RPZ). During oonetpuctIM RPZs shall be established using protective fencing enclosing an area with a radius 1.5 times the distance from the trunk to the dripline. Within this protective buffer, no grading, trenching, fill, or vegetation alteration of any kind shall be allowed. • The RPZs shall be maintained after the completion of construction in order to continue to protect the oak trees, but the ftcing shall be removed. _3. Fencing for areas other than residential areas shall be limited to a maximum of 5 wire strands. The lower strand shall be at _ least 16" above the ground and the upper strand shall be no higher than 48" above the grotmd. _4. Pay the required CSA 87 Traffic and Drainage Mitigation fee of $2,500. _5. Prior to any clearing, grading and/or construction in a Federal or State identified 100 year floodplain and/or streambed the ' following entidkmems trust be obtained. a California Fish and Game 1604 Streambed Alteration permit and an Army Corps • 404 permit or exemption certificate. _6. Pay the current West Chico Fire Station Fee of $75. —7. Pay water tender fees in the amount of $200 to Battalion Number of the Butte County Fire Department. '7` —8. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with thi Nationd*F' ire . Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 131), unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. —9. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish 8t: Game at 916-355-7,016.'- -10. 16-355-7010.-_10. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $750 as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to dee Planning Division. _ 11. Provide information showing that proposed construction will mitigate exterior sound levels to a 45 dB interior level. —12. —13. 14 K:`BLDG 14.FR.'A' tj LAND DEVELOPMENT OROVILLE / CHICO BUILDING / ENVIRONMENTAL HEALTH - PERMIT CLEARANCE MC�cA-oa OWNERS BAKER, ROBERT & PATRICIA NAME PRINT LAST NAME FIRST Building Permit No... 99-1894 A.P. 058-440–.008 NUMBER. ADDRESS/LOCATION: STONE MOUNTAIN DRIVE, OROVILLE COUNTY ZONING _ DESIGNATION: D FLOOD MAP: FLOOD ZONE: APPROVED: CONDITIONALLY APPROVED: RESOLVE PROBLEMS PRIOR40 APPROVAL: /r 9.7A , PARCEL CREATION BY DEEDS OR MAP DEED INFORMATION: DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO LEGAL ACCESS REQUIRED: ' `'VES.' NO Y - COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: YES NO COMMENTS/CONDITIONS: MAP INFORMATION: DATE OF RECORDING: �3 /CO ZZZ LOT _ BO . OK_ ­_41 PAGE .7 COMPLIANCE WITH OLDU IVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES NO . IF YES, MARK APPROPRIATE.ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BUILDING DIVISION UNLESS OTHERWISE NOTED. �. Maintain a 50 ft. building setback from centerline of road. —2. Maintain a ft. building setback from right-0f--way/centerline —3. Comply with Zoning code for building setback from road. 4. Maintain a 100 ft. leachfield setback from all existing wells. 5. Maintain a ft. leachfield setback from —6. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. X. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. _ 8. Conned to a public water supply. —9. Connect to a public sewer system. : r —10. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and, mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. -11. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ _ 12. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) _ 13. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010. _ 14. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to the Planning Division. - —15. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. —16. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors.. X 17. Pay school impact mitigation fees. X 18. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II bf the Butte County Code. _ 19. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. —20. If any cultural resources are encountered during ground disturbing'activdies, all work shall cease in the area of the find pending examination of the site by a professional archaeologist. This person would then be able to assess the site significance and suggest appropriate mitigation measures. 22. 23. 24. —25. 26. AI 11MS � JO kINnO3 3 66% E z end LD 6/98 (13103311 FORMS\BLDG PERMIT CLEARANCE 5y3.6?�' / 11 D'G�! g 73,3 7 ----�- e The attached Fire Safe ,r��iireracnt ��Splet,tb ,u speci#i� 0 ALL ���,,,,MlLUE) XCi E� B A CDF FIRE SAFE REQUIREMENTS AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building. Department for compliance. [�] 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards [�] 1273.02 Surface All driveway surfaces and structures (bridges, 1273.07 culverts and other app-arte-aant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. ( 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius [ 1. No roadway shall have a horizontal inside radius of curvature of less 'than 50 feet and additional'sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 -feet to those from 100-200 feet: [�] 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [�] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. 1273.05 Turnouts.' Shall be a minimum'of 10 feet wide and 30 I -P feet long with a minimum 25 foot taper on each end. [-] 1270.10 Width. All driveways shall provide a minimum 10 foot traf f is lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of AP # PERMIT # NAME [� 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800,feet, turnouts shall be provided'no more than 400 feet apart. Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [�] 1. Gate entrances shall be at least two feet wider than the roadway it serves. [7C] 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [ ] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space. 1. All parcels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from ull property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of ..road .construction �r f'_:ial inspection of a building permit. e Page 2 of 3 AP # PERMIT # NAME other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [ ] If Building Setback is Less Than 15 Feet Choose any3 of the following: Metal or no doors on side toward property line with insuffi= cient setback Class A or B roof with enclosed eaves Interior automatic sprinkler system per NFPA 13D Glass area not to exceed i0t of wall area toward property line with insufficient setback - Siding from the following list: Stucco -'3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature Page 3 of 3 M.H.L- Z Mobilehome Manufacturer: �'�``"'`�t Manufacture Year:_1 If other than single wide, furnish Setup Model Number: 3 1 Width: (ft.) Length: ft.) Tagalong or Expando ) On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural setup sheets. FOOTINGS: Wood pressure treated or foundation grade[C- Other: SUPPORTS: Concrete block] Other: Provide Tie Down Specifications `for•alt Mobii'ehomes:= Footiiit,'a'Sizes-`Wd Location.. -.41V sINGIZ WIDE _ .. MULTI -WIDE _ Line 1 " Lino 1........ Line 2 - Lino 2 ....................................................................................... Main Lieanu Line 2 ............ ..................................................................................�.. • 02 . Line.1 Lino 3 . Lino 2 •• � Main Ikiimt�'' .. .. .... • .......................................................................................... Lino 2 Lino 1 ........................................ Tag or Tripl t e q Line 1 Piers: ` Line 1 Openings " Size minimum: r ix v - Size minimum: [ 12 ] x [ cY j. . Spacing maximum: - ., ` Each side of openings From ends -maximum: with width over: ` Line 2 Piers: ?: Size minimum: 17-41 x befl. Spacing maximum: 14 0 " From ends -maximum: 2 o ` Line 3 Roof Loads: Size minimum Location (from front): Line 5 Roof Loads: Size minimum: Location (from front): Line 4 Piers: Size minimum: x [ ]. Spacing maximum: ` From ends -maximum: ` O VER yt,T-^-j"`ct""•"Sy��Aa,''�.•,; "y, '•vL�,.:3 .+:{�4"_'(Pr �; J�;'•„'a..+.�'�i�a� si ••r'•.$4's•7�z'. v/ .i 1.. �4.}. ,..,�-- • _ -' w-. �"E`7',--='�%�•�� �-Y�'SY.r � :t..'t'�.-., i�., � +•:''L • h `S 058-440=008 'PERMIT#94-2492 MER CADO, JOSE t. SE COR STONETMTN RD &'CONCOW RD.,'CONCOW ELE FOR WELL F r_. I r 1 YJ i COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 :2PE MIT NO. .r APPLICATION AND PERMIT r `� 11-4 ASSESSOR PARCEL NUMBER M— 40-0 ZONING - ,-1D BUILDING PERMIT OWNER JOSS JOSS %-11CIUDO SQ. FT, OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS ?fir ? L Z114 . -.300 CT. Cts 93333 CONTRACTOR'S NAME 1 -sr l TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEER uCENSE No- Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS - Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESS �+ •r+ 1:211 1) (' 'T), PERMIT FEE $ -Al", r PLUMBING PERMIT Filing Fee 20.00 Each Trap 1 1 7.00 a Solar or heat pump water heater 23.00 LOT NO. SUBDIVISION'S NAME _w _ PARCEL MAP Water piping 15.00 Each gas water heater or vent 15.00 USE OF STRUCTURE SF ElDuplex ❑ Mobilehome ❑ Other EV; roll '^;j j, SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G I W @20.00 TYPE OF WORK New ❑ Addition ❑ Remodel ElUtilities ❑ Installation ❑ Other Q Describe Work: PERMIT FEE $ Contractor ELECTRICAL PERMIT Filing Fee 20.00 I Main Service BOOV OR LESS ( 2WA OR LESS ) 23 ^^ 23.00 / J U. r Main Service ( 200A TO 1000A ) 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. ( & ACC. BLDS. ) SO, 3.50so CONST. MULTI -OUTLET NON-RESID. ( BRANCH CIRCUITS ) @7.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one) ❑ 1 am a license8 under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) ❑ I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) El am exempt under Sec. Business and Professions Code forthis reason ( POWER APPARATUS ) a SINGLE OUTLET CIR- Ex. Occup. ( OUTLET OR FIXTURES ) B20 @ 1.00 Ex. Occup.FIXED APPWS. OR (OUTLETS A=.,EA. ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 i` I T '• 13 WORKER'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a ertificate of Consent to Self -insure. I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant:.4f after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ v C� Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the grantin of this permit. IL X ;e, Date �,� Signature of Applicant ;oV Owner ❑ Contractor ❑ Agent An,OSHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ DCC CONST. TYPE TOTAL FEE $ co HAZ. 1 O. FEES I IMP I FLOOD I CDF PARCEL PD HD I ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. ' - r - BY ' 1. r Date PERMIT EXPIRES ON /Date/ %,, Receipt N0. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT LAND DEVELOPMENT OROVILI O BUILDING / ENVIRONMENTAL HEAL - PERMIT CLEARANCE Building Permit No. NAME OWNERS I f ; 1 m) NUMBER PRINT LAST NAME F I ST,�'M ADDRESS / LOCATION: l,�fm CSL C, �-0 ) c�" T O at f�/! COUNTY ZONING C� DESIGNATION: �O FLOOD MAP: ;�U FLOOD ZONE: X APPROVED: CONDITIONALLY APPROVED: RESOLVE PROBLEMS PRIOR TO APPROVAL PARCEL CREATION BY DEEDS OR MAP ✓ �' 97 4C DEED INFORMATION: DATE OF CREATION: DEED REFERENCE: - LEGAL ACCESS PROVIDED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: COMMENTS/CONDITIONS: MAP INFORMATION: LEGAL ACCESS REQUIRED: YES NO YES NO DATE OF RECORDING: —3/&/% Z LOT BOOK / PAGE COMPLIANCE WITH OLD SVB10IVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES K NO. IF YES, MARK APPROPRIATE ITEM(S) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BUILDING DIWSION UNLESS OTHERWISE NOTED. x1. Maintain a 50 ft. building setback from centerline of road. —2. Maintain a ft. building setback from right-of-way/centerline —3. Comply with Zoning code for building setback from road. —4. Maintain a 100 ft. leachfield setback from all eAsting wells. —5. Maintain a ft. leachfield setback from —6. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department. X7. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. —8. Conned to a public water supply. 9. Conned to a public sewer system. _ 10. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. -11. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ _ 12. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) —13. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010. —14. A traffic mitigation fee for each new or additional Irving unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be made to the Planning Division. —15. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies,vrith the Seismic Zone 3 requirements of the Uniform Building Code. _ 16. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. X 17. Pay school impact mitigation fees. X 18. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II of the Butte County Code. _ 19. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. _ 20. If any cultural resources are encountered during ground disturbing activities, all work shall cease in the area of the find pending examination of the site by a professional archaeologist. This person would then be able to assess the site significance and suggest appropriate mitigation measures. 21. 22. 23. 24. 25. 26. 41d iN31111dOIJUa aIW1 3.Un910 uNn00 6661 g o Nnr LD 6/98 FORMS\BLDG PERMIT CLEARANCE f REFER TO CALIFORNIA TITLE 25 =- SEE STRUCTURE REFER TO CALIFORNIA TITLE 25 - SETBACK AITACHME .. _ I THE 2007 CBC, CMC, CPC, -TA #LtI '�! �!>�� rno Annc I 1�/r I $ECT/ON 7337- SKIRTING SHALL NOT �•��M . LOAD INFORMATION FOR I41 --�^ SIT L _ FOR SLOPED BUILDING CEC, AND 2005 CALIFORNIA ENERGY STANDARDS AS BE INSTALLED UNTIL ALL UND SITES I ERFLOOR _ _ .. ._...... .. -- -. .. . nnnnnlrnrTllccn unnnc INSPECTIONS HAVE BEEN APPROVED FOR ."' '.•�""'�"' • ......�. AM ION MANUFACTURED HOME - _ - - APPLY, PLYY TO THIS PROJECT. ...:...;.._ _ _ of<".CALIFORNIA CODE '.... • ................_ . REGULATIONS 10 S T IT :.....:......•............,............:...................;_......._.........:......._.. ended b : Requirements as am :........ .. _ - dict Y ;... �� the jurisdiction apply to this ;......;... ............. .. .. .. . - project pp Y .. ..... .. .. .. ...: .. .. .. JIGI K -- B U DIN :..' P 8 �� y ..� E • �- R MI T Ea'r/ � �.'. sf D Iz d d: . - .t::...; ... t7 p: R R ;: _ e y. ;: (i f . Y/�S o P L d P D � o r Al JD' R c ...:;:.7 .... .. EL i• • •t I .. •! •V y• " .V LAI RSI �E A- I A. MK s'� ACOMPLY S N� s J F1APPROVEDi E I.. • MATERIAL _ ;��....,,....�-�,,,11� Al ➢t/��,- i• ...'....... •::..........:.i=:..........(i ........ ...;: ....: �: c. . I ..... I-,. .. _ .. ... • • �••- F - - •• _REQUIREMENTSSEE HANDOUT FOR ......:......f .. •' },:::? -b. 3.. A ` :...........:............... .....- ......,DIVISION OF FORFSTRY:............:......CURRENT INFORMATION ON APPROVED '` MATERIALS FROM FIRE CALIFORNIA . ... ' ' .. Arm .. _............-- Y MJI^! .•M -Pro ............... .. .. .. .....:...:.. ... LANDINGS AT DOORS 4 .. • I SHALL COMPLY WITH II ,.. : 2007 CBC SECTIONS :....:.. .. :...... .....:.....:.....:...................:......:............:......:............:...... .: J 1 008.1 .5, 1 009.4 & .. .. .. ............................ . .. 1010.6 i.... .. .. .. . _ .. .. I' .. _. ......................................... ............ ............:............................. :... ;......;.... � __..,..... , t I .. .. .. _. ...!..I ....: .. ..... .. .. .............. ...... :............... ........ ......................... I ALL COVERED DECKS AND :. :.. .. .. ... .. .. .. .. .. .. .. OPEN • � SQUARE FEET IN AREA WILL DECKS EXCEEDING 36 i 'REQUIRE .. t ' , • - ............. ............PER : • ..IMIT NOTE APPROVED PLANS AND ............t••• ••'v I••• �' •' E CONDITIONS PERMIT SHALL BE ON SITE ' A r il' .1 .. .-- . ........ D n p �R, .. .. . .___ SIT """"""""""""" �`r t"�" FOR ALL INSPECTIONS ,. •I• ENGINEERING MAY BE REQUIRED IF ANYNOT SHOWN FOLLOWING .:..... : : T SHOW ``��Cio�_g1111'`S' U E �Itl�S C ': V ' : � : ,'•• SITE CONDITIONS ARE OBSERVED AND _ q l TTACH L E APPROVED PLANS: •• NDNTH • - pate::' SEE�14 D `.`. .. - _ ; ;:.....;.....;....:►Js'......; ......:.......... .. CALIFORNIA HCD ...... ' �i•�EXPANSIVE SOILS L ,......,.....;. Paticln9 ja :•,,,,,;,,,,,,;,,,,, ... ..l . „ t arSr,3aad.5i+�..a•.•.� NOTICE OF EXCESSIVE CUTS OR FILLS • - -" : • • ALTERATIONS T❑ NATURAL DRAINAGE -. .. .. .rte. j AL �0"r ••" E ERGENCYACTTQ OTHER UNUSUAL SOIL OR GEOGRAPHIC '• T CONDITIONS .....:.._ ..:............................ - :....................� . ................ - - - - - ..........:......:..................:......... ........ :..... 115 ......._.. . /� - / tlrvurt. 7,UTrF PROPERTY OWNER15; RESPONSIBLE FOR PROVIDE FOR ALL Assessor's Parcel Number.. U [5� M [YJ o - ® ® a Scale: 1" O 0 DETERMINING LOCATIONS OF PROPERTY LINES - o �+ ° AND EASEMENTS AND MAINTAINING REQUIRED Owner Name' SETBACKS FROM PROPERTY LINES AND FILE COPY Address /Phone -No. 3��� 5� /��lUlilRrj o �, o 1 — - 1e ®_�1J1-- o, o , EASEMENTS.• A SURVEY MAY BE REQUIRED IF SIIP Location c/�j r. _— _�-- DETERMINED NECESSARY BY THE BUILDING "' ❑FFICIAL. ------------- FOLE C C py OWNER b/fVfftZ A P NOXV E3 p #04 0,62-26>0 A �rt 4