Loading...
HomeMy WebLinkAbout058-660-011ORUM--, Bill'218'Rich Gulch Rd, Oioviileit es for travel'trailerGASCOMPACTION TEST REQSUPPORT STRUCT REQ058-660-011 02-0919 'ORUM, BILL218 RICH GULCH RD., OROVILLNEW DETACHED GAF-�,GE � � / � :6� RESIDENTIAL 1 / C^_ PERMIT NO. -058-660-011 :02t.0919 j DRUM, BILL 218 RICH GULCH RD., OROVILLE CONTR: JAY BRYANT 4 NEW DETACHED GARAGE SPECIAL CONDITIONS CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER INALE JOB FINALED (Date) Z-- Signature Y = OK = Not OK = Not Applicable. MOBILE HOMES = Not Ready, Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ PLPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval . 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 MISCELLANEOUS Date D CKS, COVEX, CARPORTS GARAGES (Plans) OK except #'s FINAL (Plans) OK except #'s 1. Z g Requirements -Setbacks -Easements Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders andlor Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Bea ms- Rftrs.-Connectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. EIe c 9. rmg.; Sills-Anchors-Studs-Rftrs-Trusses Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 10. ed Wall Panels 11. Light Niche Date Card 13-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 /= OK 0 = Not OK = Not Applicable = Not Ready Date RESIDENTIAL (%4 Date Underfloor (Plans) OK except #'s Hangers -Post Caps -Anchors -Connectors 1. Zoning -Setbacks -Easements -Flood -Slope Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rfng. 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth Fireplace Ties or Type A Flue -Fireplace Throat Clearance 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 5. Stemwalls, Main; Steel-Blockouts-Wrapped Garage Fire Protection Framing 6. Stemwalls, Garage; Steel-Blockouts-Wrapped Property Line Firewall & Openings 6a. Hold Downs and Special Anchors Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 7. Slab, Steel -Wrapped Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 8. Piers -Fireplace Ftg.-Steel Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Siding -Nailing Veneer 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 11. Water Pipe; Test -Anchors -Regulator -Service Test Glazing Area -Glass Protection -Skylights -Plastic 12. Electric Underground Shear Walls; Nailing -Bolts 13. Plenums & Ducts; Clearance -Material -Support -Ins. Brace Interior/Exterior Wall Panels 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Insulation -Walls -Ceilings 15. Access & Ventilation Infiltration -Walls -Windows 16. Insulation Date Date Date Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s Ext. Steps -Door & Sidelight Protection -Landings 17. Water Htr.; Vent -Access -Combustion Air Baffle Smoke Detector 18. Water Pipe; Test & Anchor -Nail Protection Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection Bedroom Exiting 20. Shower Pan; Test, First Floor -Tub Access G.F.I. & Bath Fixtures & Tub Access -Spa 21. Test Tub & Shower, Second Floor -Tub Access Elec. Trim & Subpanel, Breaker Sizes & Labels 22. Gas Pipe; Sixe & Anchors Stairs & Rails 70. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date 72. ELECTRICAL (Permit) OK except #'s 23. Fixture & Transformer Clearance -Ins. Protection 24. Elec. Receptacles Spacing -Lights & Switches at Doors 25. _ Size Boxes & No. of Conductors Stapled 26. Romex Installed Close to Edge of Studs & C.J. 27. Equip: Ground made up w/Mech Fasteners -Bond Gas & Water 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or At Insulated Neutral ❑ Yes O No 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 33. Clothes Closet Light -Shower Light -Spa Light 34. Smoke Detector 84. A.C. Unit Disconnect, Electrical -Plumbing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Water Well, Disconnect, Electrical, Plumbing MECHANICAL (Permit) OK except #'s 87. 35. A.C. Ducts Insulation & Support 88. 36. Vent Fan, Exhaust above insulation 89. 37. Condensate Drain & Overflow, Size & Grade 90. 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 91. 39. Attic Access & Platform if Furnace in Attic 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Date FRAMING (Permit) OK except #'s Date 40. Sits Proper Materials & Anchors Card B-1 Date Card B-1 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 82. Following Instld./Drive ] Yes ] NoMalks ] Yes ] No/Planters 0 Yes ] No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO.' (Rev. 12/96) APPLICATION AND PERMIT 02-0919 ASSESSOR PARCEL NUMBER 1 ZONING t BUILDING PERMIT OWN%ill Orum TELEPHONE SO. FT. OCC. BUILDING VALUATION 976 U 10,368.00 . OWNERS MAILING ADDRESS 218 Rich Gulch Oroville 95966 CONTTurf ShiedTELEPHONE 916-483-T CONTRACTORS MAILING ADDRESS 3200 Orange Grove North Hj-hl nds CA 95660 CONSTRUCTION LENDER Cont. Jay Bryant CA 95660 Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 126-00 ARCHITECT OR ENGINEERS MAILING ADDRESS - Plan Checking Fee $ BUILDING ADDRESS 218 Rich Gulch Road Oroville Energy Plan Checking Fee $ $ PERMIT FEE $ LAT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome IR Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other] Describe Work: New Det Garage Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.00 a00OR LESS Main Service 200.OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, And my license is . full force and effect. ` / a i _ I cct� License Class LIC. E lllddd��� W OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. �( I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My worker�mpe satipn insurance carrier and policy number are: Carrier ��// /x.11 /.N - Policy Number UA'7S��j IQT0 —® If (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that f I should become subject to the workers' c ensation provisions of section 3700 of the Labor Code, I shall forthwith o ply wit "ose provisi S. X Date 02— Signature f Ap lican - O er Contractor ❑ Agent An OSHA ermit is required for excavations over 5'0" deep and demolition or construction of struct res over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. OWEWNOOCCUP. SO OR ADDNS. ( a.CC. BLDS. 3.5Q Noa�loNEW MULTI.OUTLET @7,50 POWER APPARATUS 8 SINGLE OUTLET CIR. Ex. OCCU OUTLET OR FIXTURES BAL @ 1:50 Ex. Occup.OFUTLEEDTSA R °E, 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT . Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 227. 90 H.z. FEES IMP FLoo CDF CEL H ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees. have been paid. By Date 1i b Z 4Y, PERMIT EXPIRES O � O pe 7-" Receipt No. a 62 WHITE-D.D.S.-B.D. CANARY -ASSES PINK -INSPECTOR GOLDENROD -APPLICANT _.-....- 4 COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER:ASSESSOR PARCEL NUMBE Ldzo Proposed Building Use: Counter Technician: Date: U Items required in order to apply for a ermi Il boxes MUST be checked OR mr ed NA in order to apply. t lot plans, 3 or 4 sets, signed by the preparer of the plans. omplete plans, 3 or 4 sets, signed by the preparer of the plans. ngineered plans, 3 or 4 sets, with wet signature on plans AND2 sets of stamped and signed calculations. ngineered truss details and layouts in duplicate. No faxes! nergy compliance design and supporting documentation in duplicate. ❑ 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ 7.. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be' indexed and returned to the plan review line-up when required items are received. q, Date Received By 8. Flood Elevation Certificate, wet -stamped and,signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... Q/�0. Letter of intent for non-residential buildings....................................................... 1. Detached Accessory Building Form filled out by the owner...................................�P ❑ 12. Hazardous Material Form............................................................................... t t. ❑ 13. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) I ❑ 14.. Fees as shown on the attached Schedule of Fees Due Sheet ....................................... Statement of Intent for Non -heated and A/C Buildings ................................. . Sanitation and plot plan approval from the Environmental Health Dep,, -------- City 7. of Chico Plumbing permit. ........................... .:......... 18. California Department of Forestry plan approval paid. Sent by: 1.�'- ...................... Y ❑ 19. Planning approval for (A) Use.- O lZ (B)Parking: (C) Parcel Check: ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... ❑ 21. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ............... :.... ................... ...... ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... ❑ 26. Letter of Signature authorization.................................................................... ❑ 27. Recorded copy of Agricultural Acknowledgment Statement .................................... ❑ '28. Manufactured home utility clearance............................................................... ❑ 29. Existing violations and/or expired permits......................................................... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: Or When issued Telephone `— t and hold for pickup. I have been informed o above ' sand requir ents fo to ing a buildin� permit. -- - i 0, oz Applicant: t F. 1. Index permit plication for the above items number Plan Check Letter ' 2. Ad ' al itogs required ac , esigner, owner, was advised of the above data by ph ne, ❑ ail, ❑counter, by _I?Y!7 Date: Facto , signer, owner, was advised of the above data by ion , ❑ mail, ❑ cou r by Date: 2,0 ed by: Date:_ Plans approved by: Date: Structural reviewed by: Date: S 2� o Structural approved by: Date: �' 0/ o Note transfer by: Date: Yellow: Building Division r TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance E.H. USE ONLY Piot Plan Anschod Roes Plan At4qftad Sant to B.D. Owner Location AP# Plan Approved for: Sewage DisposW---:,- Wa er Supply: Public Private We'41� Clearance for dwelling. Other Hold final for: Final clearance O.K. for: NOTE: Environmental Health Specialist 8/96 Date Department of Development Services Building Division 7 County Center Drive Oroville, CA 95965 (530) 538-7541 (530) 538-2140 FAX DETACHED ACCESSORY BUILDING OWNER'S STATEMENT OF USE Plan review will not be started until this form is completed, signed by the property owner, and returned to the Butte County Building Division. Attached Accessory Buildings and Additions will be checked for residential use. Exception: Garages and Carports. Owner: -, m Ov,_,Jrc1 Phone:(gco); CDz e C(_Q35— Mailing Address 1 z? ;Ute J C.OG� C I • Site Address: % i q e tck 17�S 04- ", C)COV k `�C . ca- - Assessor's Parcel Number: OS?5 ^ UQ -0 — 0` � Zone: Please answer questions 1-16, and explain any yes answers for questions 2-14 in the space provided on page 2 of this form. GENERAL INFORMATION: 1. Is there a primary dwelling on the property? Yes Jig No ❑ 2. Is the structure already built, under construction, or under notice of code violation? Yes ❑ NoIA 3. Will items produced in this building be offered for sale? Yes ❑ No 4. Will the public have access to this building? Yes ❑ No 5. Will any advertising, on or off site, be associated with the use of this building? Yes ❑ No SITE CONDITIONS: 6. Is the structure foundation within 5' of septic tank or 10' of leach lines? Yes ❑ No 7. Is any portion of the structure located closer than 20' to your front property line? Yes ❑ No 8. Do you plan to add a driveway or modify existing access to a county maintained road? Yes ❑ Nog 9. Will the proposed structure encroach within any recorded easement? Yes ❑ No CONSTRUCTION FEATURES: 10. Will this building have insulated floor, wails, or ceiling? Yes ❑ No'� 11. Will this building be heated or cooled? Yes ❑ No 0 12. Will this building have a water closet/toilet? Yes ❑ No B 13. Will this building have a sink? Yes ❑ No 14. Will this building have a water heater? Yes ❑ No 15. What type of floor covering will the building have? PoK4_ CuNG �4� 16. -What type of Lyall covering will the building have? t)oPE_, 00j,,,3 Vj3aMe 1 of 2 PROPOSED USE: (check only one box) 1. ❑ Residential Storage Shed — I will be storing /I 1 ICl(� � in this building and it will not be used for any other purpose (no bathroom and no heating or cooling). 2. % Private Garage — "A building or a portion of a building not more that 1,000 square feet (3,000 by exception) in area in which only motor vehicles used by tenants of the building or buildings on the premises are stored or kept." A Garage door is required. 3. ❑ Residential Carport — A covered structure intended for parking of vehicles. Two or more sides must be entirely open. 4. ❑ Residential Occupancy — Structures meant to be occupied, as opposed to a storage shed, garage, or carport. If you checked #4, please check the uses below which best fit this building. ❑ GuestHouse ❑ Pool House ❑ Studio Apartment ❑ In-law quarters ❑ Recreation Room ❑ Game Room ❑ Study ❑ Library ❑ Bonus Room ❑ Playroom ❑ Den ❑ Studio ❑ Artist Studio ❑ Hobby Room ❑ Craft Room ❑ Sewing Room ❑ Canning Kitchen ❑ Music Room ❑ Family Room ❑ Sun Room [; 'Private Office Q Workshop' ❑ Horne Occupancy ` ❑ 0-dier — Use = 1. Describe type of Workshop 2. `hut be approved by the Buae County Planning Division. Explanations: This area is for explanation of any "yes" answers on questions 2-14. Please indicate the question 15 ber before the explanation. 'r1kcps_ 1�- /-)�, dk c rn �T IMnln 1� Terns_ <v.� �i� !'rt,D Additional Information: Plan review will not be started until this form is completed and received. A Plans Examiner will contact the ntynsr ,�iith crpeci:C rPy:lir%meCtt$ per ibe•use ii:dIC«tCv. I hearby affirm under penalty of perjury that the above information is true and correct. I understand that any changes to the use, or character of use, of this building will require permits from the permitting authority. I understand that Real Estate Disclosure laws require disclosure of this information if or when the property is offered for sale. Owner's Name: Please /?v Owner's Si ture: Date: 2 2 of 2 Pagel of 16 C)2-o9i9 150 COW. TT 3UILDING DEPARTMENT �►PPROYP-ID/ S17 2- a Z P. lr r e Structural Calculations for Owner: Standard 24'x,24' Ranch Garage Project: 24' x 24' Ranch Garage Project # TS -96271 P.O. # 96271 Invoice # 0 Tuff Shed Store: #100 N. Highlands, CA 95660 Client: Tuff Shed Inc. 1777 S. Harrison Street Suite 600 Denver, Colorado 80210 Structural Engineer: Steven B. Brown & Assoc. 4885 Riverbend Road, Suite B Boulder, CO 80301 (303) 442-2009 Date: March 15, 2002 C)2-o9i9 150 COW. TT 3UILDING DEPARTMENT �►PPROYP-ID/ S17 2- a Z P. lr r i Page 2 of 16 Standard 24'x 24' Ranch Garage Design Criteria Building Code: 1997 UBC Allowable Soil Bearing Pressure 1000 psf Loads: Seismic Zone 4 Wind 85 mph Exposure B Roof Dead Load 10 psf Roof Live Load 30 psf Loft Dead' Load 0 psf Loft Live Load D psf Materials: Hem Fir #2 Fb 850 psi • Fv 75 psi E 1.3x106 psi Microllam LVL Fb 2600 psi F„ 285 psi E 1.9x106 psi LamHeader Fb 525 psi 700, 1000, 1100 F„ 140 psi E 0.9x106 psi LamHeader Fb 1000 psi 800, 1200, 1300, F„ 140 psi 2000 E 1.2x106 psi LamHeader Fb 1500 psi 900, 1400, 1500, F„ 190 psi 2100, 2200 E 1.9x106 psi Concrete f'c 2500 psi 1/2" A.B. Shear Capacity 1250 Ib 6eLo 1/2" A.B. Tension Capacity 950 Ib 5/8" A.B. Shear Capacity 2750 Ib 5/8" A.B. Tension Capacity 1500 Ib C SCfRIA FOUNDATION PLAN 2A'-0' ZX TREATED SOLEPIATE TYPICAL ALL W ALLS(UN O ) r ---- --------- I � I SEE FOOTING DETAIL CF. I i l NO TANDEM PARKING ALLOA'FDIN 2 WPICAL ALL 'AL3 I I b I I I ( I' I I I II � II II� II I I SCfRIA FOUNDATION PLAN I — J SSTB18 PHD2 'HOLDOWNS SHALLBE RE'TIGHTENED JUST RAOR TO COVERING THE WALL FRAMING.'231558• J ' FLOOR PLAN PH02 PLATE INTERLOCK AT CORNERS ROOF FRAMING PLAN ZX TREATED SOLEPIATE TYPICAL ALL W ALLS(UN O ) NO TANDEM PARKING ALLOA'FDIN _ SINGLE FAMILY RESIDENRAL ZONES, INDIVIDUAL PARKING SPACES SHALL a•a o BE EASILY ACCESEID • LC STUDSalwoc TYPICAL I — J SSTB18 PHD2 'HOLDOWNS SHALLBE RE'TIGHTENED JUST RAOR TO COVERING THE WALL FRAMING.'231558• J ' FLOOR PLAN PH02 PLATE INTERLOCK AT CORNERS ROOF FRAMING PLAN Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project* TS -96271 Page: 4 of 16 Subject: Headers Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 3' Header Truss bearing wall Loads: Roof _ Dead Load 10 psf Live Load 30 psf Total Load 40 psf _ Beam Span, L Use 2 2x6 #2 HF Beam 2 3' Header Loads: Roof Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x6 13.00 ft Fbv Cf Fb ,psi= 1270.8 850 • 1.3 Fv ',psi - 86.25 75 E, psi= 1,300,000 726.17 b= 3.0 in Sfey_ 6.9 0 S= 15.1 in3 Afe¢ 15.5 int A= 16.5 in' Ifer- 6.5 in' 1= 41.6 in hfeQ 5.2 in h= 5.5 in Use 2 2x6 #2 HF Beam 2 3' Header Loads: Roof Beam Span, L Use 2 2x4 #2 HF 3.25 ft Hem Fir 13.00 ft Total Load 30.00 plf w=Trib Width * TL+w2= 550.00 plf M=w 1-2/ 8= 726.17 ft*Ib R=V=w L / 2= 893.75 Ib Afe¢ 4.2 Microllam .I, cr- 1.8 in 1= 10.7 in 151/2 in h= 3.5 in Use 2 2x4 #2 HF Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x4 1 ; Total Load Fb,v Cf Fe ,psi= 1466.3 850 1.5 F; ',psi = 86.25 75 E, psi= 1,300,000 S= 39.3 in3 b= 3.0 in Sf(F 1.6 in3 S= 6.1 in3 Afe¢ 4.2 in A= 1o.5 in .I, cr- 1.8 in 1= 10.7 in hrey= 1.9 in h= 3.5 in Use 2 2x4 #2 HF End wall 700 Dead Load Fbv Cf 30 psf Total Load Fe ,psi= 3324.7 2600 1.11 900,000 Fv',psi = 327.75 285 S= 39.3 in3 A,e¢ 8.3 in A= 13.5 int E, psi= 1,900,000 150.00 h= 9 in CE) - b= 3.5 in OK Sfe¢ 2.6 in3 S= 17.6 in3 OK OK Are¢ 4.1 int A= 19.3 int OK OK Ifeq-- 4.5 in" I= 48.5 in' OK OK hfey= 2.5 in h= 5.5 in OK Use 2 51/2 ML TIW End wall 700 Dead Load 10 psf Live Load 30 psf Total Load 40 psf. Cp Defl. Limit 1.15 FL / 240 LamHeader Series 700 ft Fb,v Fti ,psi= 603.8 525 F, ',psi = 161 140 E, psi= 900,000 b= 3.5 in S,e¢ 14.4 in3 S= 39.3 in3 A,e¢ 8.3 in A= 13.5 int I, Q= 9.4 .in" 1= 176.6 in 150.00 h= 9 in Use 1 700 Series Cf 1 OK OK OK Use 2 51/2 ML Use 1 700 Series 3.25 ft 2.00 ft 70.00 plf w=Trib Width *,TL+w2= 150.00 plf CE) Defl. Limit M=w 1-2/ 8= 198.05 ft*lb 11.151 LI 240 R=V=w L / 2= 243.75 Ib Microllam LamHeader Series 51/2 TIW 700 Fb,v . Fb v Cf Fti ,psi= 2990.0 2600 Fe ,psi= 603.8 525 1 Fv',psi = 327.75 285 Fv',psi = 161 140 E, psi= 1,900,000 E, psi= 900,000 b= 3.5 in b= 3.5 in OK s,, • o.8 in3 S= 17.6 in3 OK S,, 3.9 in3 S= 39.3 in3 OK OK A,e¢ 1.1 in A= 19.3 inZ OK Afe¢ 1 2.3 in A= 13.5 in OK OK IMF 1.2 in I= 48.5 in OK Ifecr- 2.6 in 1= 176.6 in" OK OK h1eq= 1.6 in h= 5.5 in OK h= 9 in Use 2 51/2 ML Use 1 700 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project* TS -96271 Page: 5 of 16 Subject: Headers Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 4' Header Truss bearing wall Loads: Roof Dead Load 10 psf Live Load 30 psf. Total Load 40 psf Use 2 2x8 #2 HF Beam Span, L ft Tributary Width 13.00 Other Load, w2 603.8 525 Uniform Load, w plf Max Moment 550.00 Max Shear #2 Hem Fir 2x8 I 'W R=V=w L / 2= Fbv Cf Fe ,psi= 1173.0 850 1.2 F„',psi = 86.25 75 E, psi= 1,300,000 b= 3.5 in b= 3.0 in S,q= 12.7 in3 S= 26.3 in3 Ares 20.3 in A= 21.8 in' Ire¢ 14.6 in' 1= 95.3 in" hre4 6.8 in h= 7.3 in Use 2 2x8 #2 HF Beam 2 4' Header End wall Loads: Roof Dead Load 10 psf Live Load 30 psf Total Load 40 psf 4.25 ft Fb,v 13.00 ft 603.8 525 30.00 plf w=Trib Width * TL+w2= 550.00 plf M=w L2/ 8= 1241.80 ft*Ib R=V=w L / 2= 1168.75 Ib 1,900,000 Microllam h= 9 in 51/2 b= 3.5 in 150.00 Beam 2 4' Header End wall Loads: Roof Dead Load 10 psf Live Load 30 psf Total Load 40 psf Limit PC�aLDefl. 15 Fb,v Cf Fe ,psi= 603.8 525 Fb ,psi= 3324.7 2600 1.11 900,000 ft F,', psi = 327.75 285 S= 39.3 in3 Arm 10.9 in A= 13.5 in E, psi= 1,900,000 h= 9 in Uniform Load, w b= 3.5 in 150.00 OK Srr- 4.5 in3 S= 17.6 0 OK OK A, 5.3 in A= 19.3 in' OK OK Irk 10.0 in' 1= 48.5 in" OK OK hfey= 3.2 in h= 5.5 in OK #2 Hem Fir Use 2 51/2 ML Beam 2 4' Header End wall Loads: Roof Dead Load 10 psf Live Load 30 psf Total Load 40 psf LamHeader Series Limit PC�aLDefl. 15 L / 240 LamHeader Series 700 4.25 Fb,v Fe ,psi= 603.8 525 F,', psi = 161 140 E, psi= 900,000 ft b= 3.5 in Sri 24.7 in3 S= 39.3 in3 Arm 10.9 in A= 13.5 in IfeCr- 21.1 in" 1= 176.6 in" h= 9 in Use 1 700 Series Cif 1 OK OK OK Use 2 2x4 #2 HF I Use 2 5112 ML Use 1 700 Series Beam Span, L 4.25 ft Tributary Width 2.00 ft Other Load, w2 70.00 plf Uniform Load, w w=Trib Width * TL+w2= 150.00 plf CD efl. Limit Max Moment M=w LZ/ 8= 338.67 ft*lb 1.15 1 L / 240 Max Shear R=V=w L / 2= 318.75 Ib #2 Hem Fir Microllam LamHeader Series 2x4 51/2 � 700 � Fbv Cf Fbv Fbv Cf Fe ,psi= 1466.3 850 1.5 Fe ,psi= 2990.0 2600 Fti ,psi= 603.8 525 1 F„',psi = 86.25 75 F,', psi = 327.75 285 F,',psi = 161 140 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 900,000 b= 3.0 in b= 3.5 in b= 3.5 in Sri 2.8 in3 S= 6.1 in3 OKSreP 1.4 in3 S= 17.6 in3 OK S,, 6.7 in3 S= 39.3 in3 OK Are4= 5.5 in A= 10.5 in OK Arm 1.5 in A= 19.3 in OK Are¢ 3.0 in' A= 13.5 in' OK Irey_ 4.0 in 1= 10.7 in OK Irk 2.7 in' i= 48.5 in' OK Irk 5.8 in 1= 176.6 in OK hreV 2.5 in h= 3.5 in OK hr,= 2.1 in h= 5.5 in OK h= 9 in Use 2 2x4 #2 HF I Use 2 5112 ML Use 1 700 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project* TS -96271 Page: 6 of 16 Subject: Headers Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 6' Header Truss bearing wall Loads: Dead Load 10 psf Roof - Live Load 30 psf Total Load 40 psf Beam Span, L 6.25 ft Tributary Width 13.00 ft Other Load, w2 30.00 plf Uniform Load, w w=Trib Width * TL+w2= 550.00 plf Co Defl. Limit Max Moment M=w L2/ 8= 2685.55 ft*lb 11.151 11 240 Max Shear R=V=w L / 2= 1718.75 Ib #2 Hem Fir Microllam LamHeader Series 2x12 17W 5 1/2 W 900 Fb v Cf Fb v Cf Fb v Cf Fe ,psi= 977.5 850 1 Fe ,psi= 3324.7 2600 1.11 Fti ,psi= 1983.8 1500 1.15 F„',psi 86.25 75 F„',psi = 327.75 285 F„',psi = 218.5 190 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 1,900,000 b= 3.0 in b= 3.5 in b= 3.5 in Sreq= 33.0 in3 S= 63.3 in3 OK Sre¢ 9.7 0 S= 17.6 in3 OK Sreq= 16.2 in3 S= 39.3 in3 OK Area= 29.9 inZ A= 33.8 inZ OK Arecr- 7.9 inZ A= 19.3 int' OK Area_ 11.8 inZ A= 13.5 inZ OK Ireq_ 46.5 in° 1= 356.0 in' OK Ireq= 31.8 in' 1= 48.5 in° OK Ireq= 31.8 in" 1= 176.6 in" OK hreq= 10.0 in h= 11.3 in OK h,eq= 4.8 in h= 5.5 in OK h= 9 in Use 2 2x12 #2 HF Use 2 51/2 ML FUse 1 900 Series Beam 2 6' Header End wall Loads: Dead Load 10 psf Roof Live Load 30 psf Total Load 40 psf Beam Span, L 6.25 ft Tributary Width 2.00 ft Other Load, w2 70:00 plf Uniform Load, w w=Trib Width * TL+w2= 150.00 plf I CDJD Limit Max Moment M=w L2/ 8= 732.42 ft*Ib 11.151 L/ 240 Max Shear R=V=w L / 2= 468.75 lb #2 Hem Fir Microllam LamHeader Series 2x65 1/2 0 700 � Fb.v Cf Fb„ Fb,v Cf Fe ,psi= 1270.8 850 1.3 Fti ,psi= 2990.0 2600 Fb ,psi= 603.8 525 1 F„',psi = 86.25 75 F, ',psi = 327.75 285 F„',psi = 161 140 E,. psi= 1,300,000 E, psi= 1,900,000 E, psi= 900,000 b= 3.0 in b= 3.5 in b= 3.5 in Srecp 6.9 in3 S= 15.1 in3 OK 2.9 in3 S= 17.6 in3 OK S;, 14.6 in3 S= 39.3 in3 OK Area= 8.2 inZ A= 16.5 int OK Are, 2.1 inZ A= 19.3 in' OK Are¢ 4.4 in' A= 13.5 inZ OK 1req= 12.7 in' 1= 41.6 in' OK Ireq= 8.7 in° 1= 48.5 in' OK Ire¢ 18.3 in' 1= 176.6 in4 OK hreq= 3.7 in h= 5.5 in OK hreq= 3.1 in h= 5.5 in OK h= 9 in Use 2 '2x6 #2 HF a Use 2 51/2 ML FUse 1 700 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project #: TS -96271 Page: 7 of 16 Subject: Headers Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 8' Header Truss bearing wall Loads: Roof - Dead Load 10 psf Live Load 30 psf Total Load 40 psf Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x12 I ; Fby Cf Fb ,Psi= 977.5 850 1 F„',psi = ' 86.25 75 E, psi= 1,300,000 b= 3.0 in SfeQ_ 57.4 0 S= 63.3 in3 Area 39.5 in A= 33.8 in Ireq= 106.9 in" I= 356.0 in" hf, 13.2 in h= '11.3 in Does Not Work! 2 2x12 #2 HF Use 2 71/4 ML Co 8.25 ft Fby 13.00 ft F,', psi = 30.00 plf w=Trib Width * TL+w2= 550.00 plf M=w Lz/ 8= 4679.30 ft*Ib R=V=w L / 2= 2268.75 Ib 1,900,000 Microllam in IfeQ= 73.1 in" 1= 382.5 7 1/4 OK Sfe¢ 17.5 in3 Use 2 71/4 ML Co I Defl. Limit 1.15 Fby Cf 1500 F,', psi = Fti ,psi= 3202.1 2600 1.07 1,900,000 F, ',psi = 327.75 285 in SfeQ_ 32.6 in3 S= 63.8 E, psi= 1,900,000 A= 18.0 in IfeQ= 73.1 in" 1= 382.5 b= 3.5 in OK Sfe¢ 17.5 in3 S= 30.7 in3 OK NG Are¢ 10.4 int A= 25.4 in OK OK Ireq 73.1 in' 1= 111.1 in" OK NG hfeQ 6.3 in h= 7.3 in OK Use 2 71/4 ML Co I Defl. Limit 1.15 L / 240 LamHeader Series 1400 ; Use 1 1400 Series Cf 1 OK OK OK Beam 2 8' Header ' Dy Fb ,psi= 1725.0 1500 F,', psi = 218.5 190 E, psi= 1,900,000 b= 3.5 in SfeQ_ 32.6 in3 S= 63.8 in3 Are, 15.6 in A= 18.0 in IfeQ= 73.1 in" 1= 382.5 in" h= 12 in Use 1 1400 Series Cf 1 OK OK OK Beam 2 8' Header End wall Loads: Dead Load 10 psf Roof Live Load 30 psf Total Load 40 psf Beam Span, L 8.25 ft Tributary Width 2:00 ft Other Load, w2 70.00 pif Uniform Load, w w=Trib Width * TL+w2= 150.00 plf CD Defl. Limit Max Moment M=w LZ/ 8= 1276.17 ft*lb 1.16 L/ 240 Max Shear R=V=w L / 2= 618.75 Ib #2 Hem Fir Microllam LamHeader Series 2x6 VI 1 51/2 700 Fby Cf Fb•v Fby Cf Fb ,psi= 1270.8 850 1.3 Fb ,psi= 2990.0 2600 Fe ,psi= 603.8 525 1 F„',psi = 86.25 75 F, ',psi = 327.75 285 F„',psi = 161 140 E., psi= 1,300,000 E, psi= 1,900,000 E, psi= 900,000 b= 3.0 in b= 3.5 in b= 3.5 in Sreq-- 12.1 in3 S= 15.1 in3 OK Sfe, 5.1 in3 S= 17.6 in3 OK S,, 25.4 in3 S= 39.3 in3 OK Area_ 10.8 inZ A= 16.5 in' OK Are¢ 2.8 inZ A= 19.3 inZ OK Ar q= 5.8 inZ A= 13.5 inZ OK IfeQ= 29.2 in" 1= 41.6 in" OK Ire¢ 19.9 in" I= 48.5 in" OK Ireq= 42.1 in" 1= 176.6 in" OK h,q 4.9 in h= 5.5 in OK h,eq= 4.1 in h= 5.5 in OK 'h= 9 in Use 2 2x6 #2 HF Use 2 51/2 MLJ Use 1 700 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project* TS -96271 Page: 8 of 16 Subject: Headers' Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 10' Header Truss bearing wall Loads:Roof Dead Load 10 psf _ Live Load 30 psf Total Load 40 psf Beam Span, L 10.25 ft Tributary Width 13.00 ft Other Load, w2 30.00 plf Uniform Load, w w=Trib Width * TL+w2= 550.00 plf CD Defl. Limit Max Moment M=w L2/ 8= 7223.05 ft*Ib 1.15 L / 240 Max Shear R=V=w L / 2= 2818.75 Ib #2 Hem Fir Microllam LamHeader Series 2x12 191/4 IW I 2100 ► Fby Cf Fby Cf Fbv Cf Fe ,psi= 977.5 850 1 Fe ,psi= 3097.7 2600 1.04 Fb ,psi= 1552.5 1500 0.9 F„',psi = 86.25 75 F,', psi = 327.75 285 F„',psi = 218.5 190 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 1,900,000 b= 3.0 in ' b= 3.5 in b= 3.5 in Srry= 88.7 in3 S= 63.3 in3 NG S,-- 28.0 in3 S= 49.9 in3 OK Sre4 55.8 0 S= 115.1 in3 OK Are¢ 49.0 in A= 33.8 in NG Arm 12.9 in' A= 32.4 in OK Are, 19.4 int A= 22.5 in OK 1, 205.0 in 1= 356.0 in" OK leq= 140.3 in' 1= 230.8 in' OK 1', 140.3 in" 1= 862.9 in" OK hrey= 16.3 in h= 11.3 in NG hreq 7.8 in h= '9.3 in OK h= 15 in Does Not Work 2 2x12 #2 HF Use 2 91/4 M -L-1 Use 1 2100 Series Beam 2 10' Header End wall Loads: Dead Load 10 psf Roof Live Load 30 psf Total Load 40 psf Beam Span, L 10.25 ft Tributary Width 2.00 ft Other Load, w2 70.00 plf Uniform Load, w w=Trib Width * TL+w2= .150.00 plf Co Defl. Limit Max Moment M=w L2/ 8= 1969.92 ft*Ib 1.15 L / 240 Max Shear R=V=w L / 2= 768.75 lb #2 Hem Fir Microllam r LamHeader Series 2x8 I s 5 1/2 � 700 Fb,� Cf Fb,v Fb y Cf Fe ,psi= 1173.0 850 1.2 Fti ,psi= 2990.0 2600 Fb ,psi= 603.8 525 1 F„',psi = 86.25 75 F„',psi = 327.75 285 F„',psi = 161 140 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 900,000 b= 3.0 in b= 3.5 in b= 3.5 in Sre4= 20.2 in3 S= 26.3 in3 OK Sre¢ 7.9 in3 S= 17.6 in3 OK S, 39.2 in3 S= 39.3 in3 OK Arra 13.4 in A= 21.8 in' OK A, 3.5 in A= 19.3 int OK Are¢ 7.2 in A= 13.5 int OK Irerr 55.9 in' 1= 95.3 in OK Ireq_ 38.3 in" 1= 48.5 in" OK Irk 80.8 in' 1= 176.6 in' OK 'hfeq= 6.3 in h= 7.3 in OK hrey= 5.1 in h= 5.5 in OK h= 9 in Use 2 2x8 #2 HF Use 2 51/2 ML Use 1 700 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project #: TS -96271 Page: 9 of 16 Subject: Headers Designed by: SB Date: 3/15/2002 Checked by: Date: Beam 1 12' Header. Truss bearing wall Loads: Roof - Dead Load 10 psf Live Load 30 psf Total Load 40 psf Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x12 � Fb,„ Cf Fb ,psi= 12.25 ft F„ °, psi = 13.00 ft E, psi= 30.00 plf w=Tdb Width ' TL+w2= 550.00 plf M=w L2/ 8= 10316.80 ft" Ib R=V=w L / 2= 3368.75 Ib Ire¢ 350.0 Microllam 356.0 in' hfeq 19.5 in h= 191/2 OK Does Not Work! A, 2 2x12 #2 HF Fb ,psi= 977.5 850 1 F„ °, psi = 86.25 75 E, psi= 1,300,000 327.75 285 w=Tdb Width = TL+w2= b= 3.0 in Sf cr- 126.7 in3 - S= 63.3 in3 Afeq_ 58.6 in A= 33.8 in Ire¢ 350.0 in' 1= 356.0 in' hfeq 19.5 in h= 11.3 in OK Does Not Work! A, 2 2x12 #2 HF Fb,,, Cf Use 2 91/2 ML Beam 2 12' Header End wall Loads: Roofv Dead Load 10 psf Live Load 30 psf Total Load 40 psf Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x10 I ; . Fb,„ Cf Fe ,psi= 1075.3 850 1.1 F„',psi = 86.25 75 E, psi= 1,300,000 b= 3.0 in Sfeq= 31.4 in S= 42.8 in A,eq= 16.0 in A= 27.8 in Ireq= 95.4 in' 1= 197.9 in' hfeq 7.9 in h= • 9.3 in Use 2 2x10 #2 HF 12.25 Fti ,psi= 3086.5 2600 1.03 ft E, psi= F, %psi = 327.75 285 w=Tdb Width = TL+w2= 150.00 plf E, psi= 1,900,000 ft'Ib R=V=w L / 2= 918.75 Ib b= 3.5 in Microllam NG S,e¢ 40.1 in3 S= 52.6 in OK NG A, 15.4 in A= 33.3 int OK OK I,eq= 239.5 in 1= 250.1 in OK NG hfeQ 9.4 in h= 9.5 in OK Use 2 91/2 ML Beam 2 12' Header End wall Loads: Roofv Dead Load 10 psf Live Load 30 psf Total Load 40 psf Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x10 I ; . Fb,„ Cf Fe ,psi= 1075.3 850 1.1 F„',psi = 86.25 75 E, psi= 1,300,000 b= 3.0 in Sfeq= 31.4 in S= 42.8 in A,eq= 16.0 in A= 27.8 in Ireq= 95.4 in' 1= 197.9 in' hfeq 7.9 in h= • 9.3 in Use 2 2x10 #2 HF Co I Defl. Limit 1.15 L/- 240 LamHeader Series 2200 IV 12.25 ft Fby 2.00 ft E, psi= 70.00 plf w=Tdb Width = TL+w2= 150.00 plf M=w 12/ 8= 2813.67 ft'Ib R=V=w L / 2= 918.75 Ib 1,900,000 Microllam 1 2200 Series 71/4 OK Sreq= 11.3 in' Co I Defl. Limit 1.15 L/- 240 LamHeader Series 2200 IV FbV Fe ,psi= Fby F„',psi = 218.5 190 E, psi= Fe ,psi= 2990.0 2600 b= 3.5 in S,eq= 79.7 in' S= 126.5 in F„',psi = 327.75 285 Ife¢ 239.5 in 1= 948.4 in' E, psi= 1,900,000 Not Work! 1 2200 Series b= 3.5 in OK Sreq= 11.3 in' S= 30.7 in OK OK Afeq= 4.2 in A= 25.4 in OK OK Ifeq= 65.3 in" 1= 111.1 in' OK OK hfeq= 6.1 in h= ' 7.3 in OK Use 2 71/4 ML Co I Defl. Limit 1.15 L/- 240 LamHeader Series 2200 IV C. FbV Fe ,psi= 1552.5 1500 F„',psi = 218.5 190 E, psi= 1,900,000 Af, b= 3.5 in S,eq= 79.7 in' S= 126.5 in AfeQ_ 23.1 in A= 22.5 in Ife¢ 239.5 in 1= 948.4 in' h= 15 in Does Not Work! 1 2200 Series C. I Defl. Limit 1.15 L/ 240 0 M• OK NG OK LamHeader Series 800 IW Fb,„ Cf Fe ,psi= 1190.3 900 1.15 F„',psi = 161 140 E, psi= 1,200,000 Use 1 800 Series b= 3.5 in ,f, 28.4 in3 S= 39.3 in OK Af, 8.6 in A= 13.5 in OK Ifeq 103.4 in' 1= 176.6 in' OK h= 9 in Use 1 800 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project #: TS-96271 Page: 10 of 16 Subject: Headers Designed by: 'SB Date: 3/15/2002 • Checked by: Date: Beam 1 14' Header Truss bearing wall Loads: Dead Load 10 psf Roof - Live Load 30 psf Total Load 40 psf Beam Span, L 14.25 ft Tributary Width 13.00 ft Other Load, w2 30.00 plf Uniform Load, w w=Trib Width * TL+w2= 550.00 plf CD I Defl. Limit Max Moment. M=w 1-2/ 8= 13960.55 ft*Ib 11.151 L/ 240 Max Shear R=V=w L / 2= 3918.75 Ib #2 Hem Fir Microllam LamHeader Series 2x12 111/4 2200 Fb,,, Cf Fb„ Cf Fb,,, Cf Fb' ,psi= 977.5 850 1 Fti ,psi= 3016.4 2600 1.01 Fti ,psi= 1552.5 1500 0.9 F„', psi = 86.25 75 F„ ',psi = 327.75 285 F„ ', psi = 218.5 190 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 1,900,000 b= 3.0 in b= 3.5 in b= 3.5 in S,e¢ 171.4 in3 S= 63.3 in3 NG Sferr- 55.5 0 S= 73.8 in3 OK S,e¢ 107.9 in3 S= 126.5 in3 OK Afe¢ 68.2 in A= 33.8 in NG A/e¢ 17.9 int A= 39.4 int OK Ai cr- 26.9 in A= 22.5 in NG Ire¢ 550.9 in 1= 356.0 in' NG Ire¢ 376.9 in' 1= 415.3 in' OK I, q= 376.9 in' 1= 948.4 in' OK h,eq= 22.7 in h= 11.3 in NG h1eQ 10.9 in h= 11.3 in OK h= 15 in Does Not Work! Does Not Work! 2 2x12 #2 HF Fuse 2 111/4 IVILI F 1 2200 Series Beam 2 14' Header End wall Loads: Dead Load 10 psf Rif Live Load 30 psf _ Total Load 40 psf Beam Span, L 14.25 ft Tributary Width 2.00 ft Other Load, w2 70.00 plf Uniform Load, w w=Trib Width * TL+w2= 150.00 plf CE) Defl. Limit Max Moment M=w 12/ 8= 3807.42 ft*Ib 11.151 L/ 240 Max Shear R=V=w L / 2= 1068.75 lb #2 Hem Fir Microllam LamHeader Series 2x10 71/4 � 800 � Fb,� Cr Fb„ Fb„ Cf Fb ,psi= 1075.3 850 1.1 Fb ,psi= 2990.0 2600 Fe ,psi= 1190.3 900 1.15 F„',psi = 86.25 75 F,,',psi = 327.75 285 F, ',psi = 161 140 E, psi= 1,300,000 E, psi= 1,900,000 E, psi= 1,200,000 b= 3.0 in b= 3.5 in b= 3.5 in SreQ_ 42.5 in3 s= 42.8 in3 OK Sfe - 15.3 in3 S= 30.7 in3 OK S1e¢ 38.4 in3 S= 39.3 in3 OK Amq-- 18.6 in A= 27.8 in OK A,e¢ - 4.9 in A= 25.4 int OK A,e¢ 10.0 in A= 13.5 in OK Irey_ 150.2 in' i= 197.9 in' OK Ire¢ 102.8 in" i= 111.1 in' OK I,e¢ 162.8 in' 1= 176.6 in' OK hfea 9.2 in h= 9.3 in OK tr,= 7.1 in h= 7.3 in OK h= 9 in Use 2 2x10 #2 HF Use 2 71/4 ML Use 1 800 Series Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Gar Project #: TS -96271 Subject: Headers Designed by: SB Checked by: Beam 1 16' Header Truss bearing wall Loads:Roflf - Dead Load 10 psf Live Load 30 psf Total Load 40 psf Beam Span, L Tributary Width Other Load, w2 Uniform Load, w Max Moment Max Shear #2 Hem Fir 2x12 � Fb,„ Cf Fe ; psi= 977.5 850 1 F„ %psi = 86.25 75 E, psi= 1,300,000 b= 3.0 in Sreq= 229.8 in S= 63.3 in' AfeQ= 78.9 in A= 33.8 int Ire,= 855.2 in' 1= 356.0 in hf, 26.3 in h= 11.3 in Does Not Work! 2 2x12 #2 HF Flay Cf Fb ,psi= 2928.0 2600 0.98 F„',psi = 327.75 285 16.50 ft 1,900,000 13.00 ft 1552.5 1500 30.00 plf w=Trib Width * TL+w2= 550.00 plf M=w► L2/ 8= 18717.19 ft*Ib R=V=w L / 2= 4537.50 Ib A= 49.0 int Microllam NG Ire,= 14 1= 800.3 in OK Flay Cf Fb ,psi= 2928.0 2600 0.98 F„',psi = 327.75 285 Use 2 14 ML Beam 2 16' Header End wall E, psi= 1,900,000 Fb,„ Fb' ,psi= 1552.5 1500 Dead Load 10 psf b= 3.5 in E, psi= NG sreq_ J6.7 in S= 114.3 in OK NG A, 20.8 in' A= 49.0 int OK NG Ire,= 585.2 in' 1= 800.3 in OK NG hfeQ 12.6 in h= 14.0 in OK Use 2 14 ML Beam 2 16' Header End wall 1.15 Loads: Fb,„ Fb' ,psi= 1552.5 1500 Dead Load 10 psf 218.5 190 E, psi= Roof 1W b= 3.5 in Sfe,_ 144.7 in S= 126.5 in AfeQ_ 31.1 in A= 22.5 in Ifeq= 585.2 in' I= 948.4 in' Live Load 30 psf h= 15 in Does Not Work ! 1 2200 Series Total Load 40 psf Beam Span, L 16.25 ft Tributary Width 2.00 ft Other Load, w2 70.00 plf Uniform Load, w w=Trib Width * TL+w2= 150.00 plf Max Moment M=w 1-2/ 8= 4951.17 ft*Ib Max Shear R=V=w L / 2= 1218.75 Ib #2 Hem Fir Microllam 2x12 91/4 Fb,v Cf Fb,v Fe ,psi= 977.5 `850 1 Fti ,psi= 2990.0 2600 F„ ', psi = 86.25 75 F,', psi = 327.75 285 E, psi= 1,300,000 E, psi= 1,900,000 b= 3.0 in b= 3.5 in Sreq= 60.8 in S= 63.3 in' OK Sreq 19.9 Ina S= 49.9 Ina OK AfeQ= 21.2 in A= 33.8 in OK Afeq 5.6 in A= 32.4 in OK Ireq= 222.8 in° 1= 356.0 in° ; OK Ifeq= 152.4 in' 1= 230.8 in' OK hr ,= 11.0 in h= 11.3 in OK h,ey= 8.1 in h= 9.3 in OK Use 2 2x12 #2 HF I I Use 2 91/4 ML Page: 11 of 16 Date: 3/15/2002 Date: CID I Defl. Limit 1.15 L/ 240 LamHeader Series 2200 Fb ,psi= 1035.0 900 Fb,„ Fb' ,psi= 1552.5 1500 F„',psi = 218.5 190 E, psi= 1,900,000 S= 63.8 m3 b= 3.5 in Sfe,_ 144.7 in S= 126.5 in AfeQ_ 31.1 in A= 22.5 in Ifeq= 585.2 in' I= 948.4 in' h= 15 in Does Not Work ! 1 2200 Series Co I Defl. Limit 11.151--L/ 240 LamHeader Series 1200 Use 1 1200 Series NG NG OK Cf 1 OK OK OK o,v Fb ,psi= 1035.0 900 F„',psi = 161 140 E, psi= 1,200,000 b= 3.5 in SfeQ= 57.4 in S= 63.8 m3 AMP 11.4 in A= 18.0 in Ife¢ 241.4 in 1= 382.5 in h= 12 in Use 1 1200 Series NG NG OK Cf 1 OK OK OK Steven B. Brown & Associates Consulting Engineers Project: Standard 24' x 24' Ranch Garage Project #: TS -96271 Page: 12 of 16 Subject: Designed by: SB Date: 3/15/2002 Checked by: Date: Anchor_ Bolts Assume walls take shear in proportion to their length. Reaction Rv is the same for each segment in a wall line. Anchor Bolt Diameter, in 5/8 Width Pwind Wall A w. L Lengths, ft = 11 Rv Rh TRV Width= 11 ft Total, ft 11 Height= 8.1 ft Rh=Pwind= 1510 Ib Rv= . 1112 Ib Rv<1500 -> 5/8" AB A.B. Interaction No Holdowns Required 1510 / 3 / 2750+1112 / 1500= 0.92 <1 OK # of 5/8" A.B. = 1 A.B. Spacing= Code Min of 6'0.C. Width Pwind Wall C L rn ft i Rv Rh tv Width= 8 ft Total, ft 8 Height= 8.1 ft Rh=Pwind= 1 b84.0 Ib Rv= 1098 Ib Rv<1500 -> 5/8" AB A.B. Interaction No Holdowns Required 1084 / 3 / 2750+1098 / 1500= 0.86 <1 OK # of 5/8" A.B. = 1 A.B. Spacing= Code Min of 6' O.C. Width Pwind - Wall B w L 3ngths, ft = 4 TlY f — Rv Rh Rv Width= 4 ft Total, ft 8 Height= 8.1 ft Rh=Pwind= 755.0 Ib Rv= 1529.0 Ib Rv<3610 -> PHD2 A.B. Interaction Rv<"20 -> SSTB16 755 / 2 / 2750+1529 / 1500= 1.16 >1 NG # of 5/8" A.B. = 1 . A.B. Spacing= Code Min of 6'0.C. , Width Pwind Wall D L m Segment Lengths, ft = 8 I Rv ♦ Rh TIRV Width= 8 ft otal, ft 8 Height= 8.1 ft Rh=Pwind= 1084.0 Ib Rv= 1098 Ib Rv<1500 -,> 5/8" AB ,.B. -Interaction No Holdowns Required 1084 / 3 / 2750+1098 / 1500= 0.86 <1 OK # of 5/8" A.B. = 1 A.B. Spacing= Code Min of 6' O.C1 Soil Bearing Pressure Footing Width, in = 12 Soil Bearing Pressure Under Footing=(Roof & Loft DL+LL) Width/2 + Wall Wt x Wall Ht + Footing Wt Soil Bearing Pressure Under Footing= * 786. psf < 1000 psf Good Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Garage Project #: TS -96271 Page: 13 of 16 Subject: Lateral Analysis Designed by: SB Date: 3/15/2002 Checked by: Date: Wall Height, ft 8.1 Building Width, ft 24 Building Length, ft 24 Roof DL, psf 10 Wall DL, psf 10 Seismic Zone 4 Roof Pitch, in/ft 4 Roof Height Above Top of Wall, ft 4.00 Shortest Wall, ft= 4 Seismic Wind UBC ' 97 Base Shear Eq. 30-5 UBC ' 97 Wind Pressure Eq. 20-1 UBC ' 97 Load Combinations 1612.3.1: E/1.4 V=(2.5Ca/R)W/1.4 P=CeCggslw P = 1.00 Wind Speed= 85 mph Exposure B Ca=.44 x Na Cq walls = 1.3 Na= 1.1 UBC Sec 1629.4.2 Cq roof= 1.5 Ce = 0.62 Ca 0.48 Iw = 1 qs = 18:5 psf R= 5.50 Pwans = 14.93 psf W=RoofoL x Width x Length + 2 (Width+Length) Height/2 x WallDL Proof = 17.23 psf W= 9648.0 Ib Minimum Wind Wall Shear (Wind Against Gable End) Seismic Wall Shear V=Pwalls x Width x (Wall Ht/2+Roof Ht/2) V= 1516.1 Ib V= 2L,6_8,,9 Ib - Wind Controls 4._0_0 Shear Diaphragms -14 12.6\ ;12 Roof Pwind wall= Palls x Wall Ht/2 x Building Len/2 4.00 ft Pwind wall= 725.7 Ib Pwind roof --Proof x 4/12.65 x Building Width/2 x Building Len/2 Pwind roof= 784.5 Ib 8.1 ft htotal=Pv✓ind wall+Pwind roof Ptotai= 1510.2 Ib Wind Load Along Top -of Long Wall, W= 125.9 plf M roof diaphragm = - 9,061 ft"llb V roof diaphragm = 62.9 Ib/ft 8d@6" and 12" Field „ Using 15/32" Plywood `Chord.Stress= 71.9 psi < 525 psi hord Splice Nailing=. 4 - 16d Nails Each Side of Splice Drag Strait Nailing= 6 " O.C. w/ 16d Minimum Shear Wall Nailing Requirements using Duratemp 8d @ 6" Edges and @ 12" Field - has 213 plf Capacity Wall A Length, ft = 11 Duratemp with V Wall A, Of = 137.3 Min Nailing Number of A35 along Wall A = 4 Bearinq Walls Wall C Length, ft = 6 Duratemp with V wan c, Of = 135.5 Min Nailing OK � wind roof wind wall 2 v M for #2 Hem Fir Wall B Length, ft = 8 Duratemp with V wan e. Of = 188.8 Min Nailing Number of A35 along Wall B = 4 Wall D Length, ft = 8 Duratemp with V Wall D, Of = 135.5 Min Nailing h Steven B. Brown & Associates Consulting Engineers Project Standard 24'x 24' Ranch Garage Project #: TS -96271 Page: 14 of 16 Subject: Designed by: SB Date: 3/15/2002 Checked by: Date: Wall Height, ft 8.1 Building Width, ft 24 Building Length, ft 24 Roof DL, psf 10 . Wall DL, psf 10 Floor DL, psf 50 Truss / Rafter Ties Wind Uplift= (12/12.65*0.9*Pwind-0.9*Roof 0L)*Width8WIdi„ g/2*2 Wind Uplift= 137.05 lb Uplift<365 Ib. Use H2.5 Ties Overturning 4.00 ---- t Up wind 12.6 12 4.00 ft P wind 8.1 ft � DL 24 ft R, R2 WDL=(90%)(Roof+Walls+Floor) for 1/2 the Building , Pwind=P total (see Lateral calcs) Up wind=(vert component x Cq) P Area/2=12/12.65 x .9 P Width xLength/2 MOT= P wind x Ht + Up wind x Width/2 Mres=WDL x Width/2 Mres/MoT= 3.62 OK 1.5 x MOT= 94,602 ft*Ib Mor Want =1.5 Mres WDL= 19051.2 Ib Pwind= 1510 Ib Up wind= 4236 Ib Mo -r= 63,068 ft*Ib Mres 228,614 ft*Ib Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Garage Project #: TS -96271 Page: 15 of 16 Subject: Lam Header Design tables Designed by: SB Date: 3/15/2002 Checked by: Date: 2X4 LAMHEADER ALLOWABLE DESIGN PROPERTIES (100% Load Duration) BEAM GRADE/ DEPTH FLANGE FLANGE WEB WEB AREA E I S SHEAR MOMENT WEIGHT MATERIAL WIDTH DEPTH DEPTH WIDTH - (in) (in) (in) (in) (in) (int) (psi) (in") (in') (Ibs) (in -lbs) (Ib/lin ft) 700 Stud WW 9 3.5 1.5 6 1.5 19.50 900,000 176.63 39.25 2,730 20,606 4.5 800 Sel Str WW 9 3.5 1.5 6 1.5 19.50 1,200,000 176.63 39.25 2,730 40,624 4.5 900 Set Str DF 9 3.5 1.5 6 1.5 19.50 1,900,000 176.63 39.25 3,705 67,706 4.5 1000 Stud WW 12 3.5 1.5 9 1.5 24.00 900,000 382.50 63.75 3,360 33,469 5.5 1100 Stud WW 12 3.5 3 6 1.5 30.00 900,000 468.00 78.00 4,200 40,950 6.9 1200 Sel Str. WW 12 3.5 1.5 9 1.5 24.00 1,200,000 382.50 63.75 3,360 57,375 5.5 1300 Sel Str. WW 12 3.5 3 6 1.5 30.00 1,200,000 468.00 78.00 4,200 70,200 6.9 1400 Set Str DF 12 3.5 1.5 9. 1.5 24.00 1,900,000 382.50 63.75 4,560 95,625 5.5 1500 Set Str DF 12 3.5 3 6 1.5 30.00 1,900,000 468.00 78.00 5,700 117,000 6.9 2000 Set Str. WW 15 3.5 3 9 1.5 34.50 1,200,000 862.88 115.05 4,830 93,191 7.9 2100 Set Str DF 15 3.5 3 9 1.5 34.50 1,900,000 862.88 115.05 6,555 155,318 7.9 2200 Set Str. DF 15 3.5 4.5 6 1.5 40.50 1,900,000 948.38 126.45 7,695 170,708 9.3 2X4 LAMHEADER ALLOWABLE DESIGN PROPERTIES (115% Load Duration) BEAM GRADE/ DEPTH FLANGE FLANGE WEB WEB AREA E I S SHEAR MOMENT WEIGHT MATERIAL WIDTH DEPTH DEPTH WIDTH (in) (in) (in) '(in) (in) (in') (psi) (W) (in') (Ibs) (in-Ibs) (Ib/lin ft) 700 Stud WW 9 3.5 1.5 6 1.5 19.50 900,000 176.63 39.25 3,140 23,697 4.5 800 Set Str WW 9 3.5 1.5 6 1.5 19.50 1,200,000 176.63 39.25 3,140 46,717 4.5 900 Set Str DF 9 3.5 1.5 6 1.5 19.50 1,900,000 176.63 39.25 4,261 77,862 4.5 1000 Stud WW 12 3.5 1.5 9 1.5 24.00 900,000 382.50 63.75 3,864 38,489 5.5 1100 Stud WW 12 3.5 3 6 1.5 30.00 900,000 468.00 78.00 4,830 47,093 6.9 1200 Set Str. WW 12 3.5 1.5 • 9 1.5 24.00 1,200,000 382.50 63.75 3,864 65,981 5.5 1300 Set Str. WW 12 3.5 3 6 1.5 30.00 1,200,000 468.00 78.00 4,830 80,730 6.9 1400 Set Str DF 12 3.5 1.5 9 1.5 24.00 1,900,000 382.50 63.75 5,244 109,969 5.5 1500 Set Str DF 12 3.5 3 6 1.5 30.00 1,900,000 468.00 78.00 6,555 134,550 6.9 2000 Set Str. WW 15 3.5 3 9 1.5 34.50 1,200,000 862.88 115.05 5,555 107,169 7.9 2100 Set Str DF 15 -3.5 3• 9 1.5 34.50 1,900,000 862.88 115.05 7,538 178,615 7.9 2200 Set Str. DF 15 3.5 4.5 6 1.5 40.50 1,900,000 948.38 126.45 8,849 196,314 9.3 } Steven B. Brown & Associates Consulting Engineers Project: Standard 24'x 24' Ranch Garage Project #: TS -96271 Page: 16 of 16 Subject: Duratemp Designed by: SB Date: 3/15/2002 Checked by: Date: Duratemp Siding & CDX Shear Wall Schedule Based on I.C.B.O. Report No.: ER -4856 and A.P.A. Report Thickness, in Nail Size,, d Nail Spacing, in Allowable Allowable Shearon Shearon Hem Fir • Doug Fir Studs, plf Studs, plf 1/2 8 6 213 260 1/2 8 4 312 380 (7) 1/2 8 3 402 (7) 490 (7) 1/2 8 2 525 (7) 640 (7) .1/2 10 6 254 310 1/2 10 4 377 (7) 460 (7) 1/2 10 3 492 (7) 600 (7) 1/2 10 1 2 631 (7) 770 (7) Notes: 1) Use 5/8" dia. Anchor Bolts at Spacing = (880 x 1.33) / (Actual Wall Shear), in feet 2) Use plate washers with a min. of 2" x 2"=X V at each anchor bolt in shear walls. 3) Use 16d common nails at bottom plate nailing into wood framing below. Spacing=(141 x 1.33 x 12) / (Actual Wall Shear), in inches 4) Duratemp shall be installed per I.C.B.O. Report No.: ER -4856 5) Duratemp shear panels shall be nailed with common nails at all edges as noted and nailed at 12" o.c. at intermediate framing members. t 6) Nails shall be common or galvanized box nails. 7) Framing members shall be minimum 3x lumber at abutting panels and at foundation sill plates. Edge nailing shall be staggered. 10 RESIDENTIAL 58-66-11 1294-91P,E ORUM, Bill 218 Rich Gulch Rd, Oroville (utilities for travel trailer) I t ti OFFICE COPY Address ` =BY --\— Date I ELECTRIC Meter By—„eI DateGs } JOB FINALED (Date) 1 Signature ircrr_o` C 1/ =OK, 0 ='Not OKNot . '=Not Readyable 'MOBILE HOMES Date MOLE HOME UTILITIES (Plans) OK except #'s 1�ng Requirements -Setbacks -Easements 2_saifs; special MH Support Sketch 3. S r; Location -Test -Fall -C/O Concrete ' ter; Location -Test -Easement Needed (Sketch) vf Electricity; Location-Clearences-Grnd mp-Concrete 6. Gas, - : / P'L"ft. / /"Nat. or/ /"L"ft. /"LPG 7. Utility Clearance Date Card B-1 Date Card B-1 Date o 7JL/Gl, Card B-1 Date Card B-1 Date 'MOBILE HOME INSTALLATION (Plans) OK except tt's 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances S. Drain; MH Test -fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except N's 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rttrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except If's 1. Setbacks -Easements 2 Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit _ 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date -Card B-1 Date Card B-1 -J=QI{i O= Not Applicable ' = Not Ready RESIDENTIAL- (; Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel -Bloc kouts-Wrapped J 6a. Hold Downs and Special Anchors .• 7. Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 10. Gas Pipe; Size -Anchors 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 16. Water Htr.; Vent -Access -Combustion Air -Baffle 17. Water Pipe; Test & Anchor -Nail Protection „j 18. D.W.V.; Test -Fittings & Anchor -Nail Protection 19. Shower Pan; Test, First Floor -Tub Access 20. Test Tub & Shower, Second Floor -Tub Access 21. Gas Pipe; Size & Anchors Date Card B71 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 22. Fixture & Transformer Clearance -Ins. Protection 23. Elec. Receptacles Spacing -Lights & Switches at Doors 24. Size Boxes & No. of Conductors -Stapled 25. Romex Installed Close to Edge of Studs & C.J. 26. Equip. Ground made up w/Meth. Fastners-Bond Gas & Water 27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI 28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al. Insulated Neutral ❑ Yes ❑ No 30. Service -Riser Conductors & Ground -Main Disconnect 31. Equip. Clearances Panels-Motors-Mech. Equip. 32. Clothes Closet Light -Shower Light -Spa Light 33. Smoke Detector Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 34. A.C. Ducts Insulation & Support 35. Vent Fan; Exhaust above insulation 36. Condensate Drain & Overflow; Size & Grade 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnance in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Plans) OK except #'s 39. Sils. Proper Material & Anchors 40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 41. Bearing Walls over Girders & Floor Nailing 42. Draft Stop in Walls (rat proof) 43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 44. Headers & Beam -Size & Bearino (NOTE: An entry must be made >ingle & Duplex) Date FRAMING (Continued) 45. Hangers -Post Caps -Anchors -Connectors 46. Cing. Joist-Rftr. ties-Purlin-roof Brac-Truss-Shthng.-Ring. 47. Fireplace Ties or Type A Flue -Fireplace Throat clearance 48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 50. Garage Fire Protection Framing 51. Property Line Firewall & Openings 52. Ext. Doors -One T -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55. Siding -Nailing Veneer 56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 57. Glazing Area -Glass Protection -Skylights -Plastic. 58. Shear Walls; Nailing -Bolts 59. Insulation -Walls -Ceilings 60. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 61. Ext. Steps -Door & Sidelight Protection -Landings 62. Smoke Detector 63, Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Mach. Protection 64. Bedroom Exiting 65. G.F.I. & Bath Fixtures & Tub Access -Spa 66. Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails 68. Fireplace or Stove; Clearances -Hearth 69. Elec. Outlets at Wood Panel; Int. & Ext. 70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 71. Elec. Outlets & Receptacles at Kit. Counter 72. Garage Fire Door; Swing -Landing -Closer 73. A.C. Duct in Garage -Damper 74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor-Mech. Protection 75. Plb., Elec. & Mech. Equip. Listed for Location 76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 77. Insulation -Foam -Looked in Attic ❑ Yes 78. Guard Rails & Deck Constryc Caps 79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 81. Stucco; Brown -Finish 82. A.C. Unit; Disconnect, Electrical, Plumbing 83. Vents Above Roof; PIbg.-Appliance-Fireplace. -Cl earance to Openings 84. Water Well; Disconnect, Electrical, Plumbing 85. Exterior Elec. Trim; G.F.I. Receptacle -Underground 86. Ventilation Throughout House 87. Glass Protection 88. Corrections from Previous Inspections 89. Gas Test -Meters Tagged; Gas -Electric 90. Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: ! each time you visit job site) Y COUNTY OF BUTTE J DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Orovi Ile — Phone: 538-7541 747 Elliott Road, Paradise — Phone: 872-6307 CORRECTION NOTICE OWNER, PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. Date4K Inspector �' 3y 5Y, Date4K Inspector �' COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. �.a 7 County Center Drive - Orovllle, Callfornla 95985 - Telephone: 918/538-7541 Z__ 9 Y—W APPLICATION AN%-!*ERMIT , T 1/ a NUM0914 0 66 MT 9'26 t ZON FR -10 BUILDING PERMIT 011110rum (408) T IMMS SO. FT. OCC. BUILDING VALUATION OWZ2�gJoo�Stoc%R�t., Milpitas, CA 95035 CO�} TR ACTOR'S NAME UnKnoWn TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER one UNKNOWN Total Valuation is Filing Fee $ }e! LENDER'S MAILING ADDRESS Permit Fee $ ARfYHHIne CT OR ENGINEER LICENSE NO. Plan Checking Fee $ 1 O 1 Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BufiG Rich sdulch Road, Oroville Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. 11 SUBDIVISION NAMPARCEL Deer Peak Est. MAP RY� Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF F1Duplex❑ Mobilehomeyk Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S G W I O.00ea 4 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ UtilitiesH Installation❑ Other ❑ Describe work: MHU for TT Permit Fee $ 40 00 Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service sDOV OR LESS 100 AMP OR LESS 10.00 10.00 Main service EA. ADD'L 100 AMP 2.50 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered �for sale. (Sec. 7044) 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.tr New DONS.' ( A BI , hQsgft ULT OUTLET NON.RESID BRANCH CIRC ITS 2.50 ea APPARATUS tr (SINGLE OUTLET CIR. (SINGLE Ex. Occup\OUTLETS OR FIXTURES 2ALO 5AL030 \ Ex. Occup. OUTLETSP(RESID IRE A./ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 9 15.00 Permit Fee $ 37.50 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate Consent to Self -Insure. hall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed.revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating . Cooling g Hood 3.00 Ventilation Permit Fee $ Contractor ! I certify that I have read this application and state that the above information y is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liab' ' ' judgme is c.ost.s�aa�-exile es which may in any way accrue agai t said C o f the grantln s permit. X Date l/ Signature o Applicant — Owner Contractor Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE - TOTAL F 92.5 ' I HAL 1 CU66_PARK I SCHL I F I WPAR PD I D Is This permit is hereby issued under tne.applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated abo a for which fees have been paid. E, VORpf FYBLIC WORKS f� By Date ' 2 ` PE MIT EXPIRES Date ^2 Receipt No. 88891-92.50 WHITE-O.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT } ;• -� -,, n '�• �x y++,.yw+.,�,_,n,x�rrY�r+^►ti`rg7.°"�"'- ;or. fir^.-•!r*++.r ., lv''.'+`"_'.,yX�?*' jam.+ �;�h ,-y.:�.... ,r -t,. M..,•� ...Y'.+t, *a..• .. n Yr+ COUNTY OF BUTTE - DEPARTMENT'0411BLIC WORKS 4 -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CRL4 A 95965 -TELEPHONE. 916/538-7541 PERMIT APPLICATION DATA SHEET ° Permit No. -' 6600( 0 i OWNER t L � �U �-.-= A. P. No. Proposed Building Use Building Inspector Date:l�T9/ At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED 1. All items have been submitted . ................................ ... 2. Plot plans in duplicate/triplicate, signed by preparer of plans. 3. Complete plans in duplicate/triplicate, signed by preparer. of plans . . 4. Complete engineered plans and calcs, with wet signature on plans .. 5. Hazardous Material Form .......................................... 6. Energy Design Compliance and supporting documentation ......... f' 7. Statement of Intent for Non -Heated and AC Buildings 8. Engineered truss details and layout in duplicate (required prior to plan check) 9. Mobilehome installation data including manufacturer's installation t instructions. IF' 10. Fees of $ 11. ..... ................... Chico Urban Area fees paid ....................................... 12. Park fees paid .................................................... 13. School District fees paid .............. 14. Sanitation approval from �►�%(� Pp Health Department -G// A10 _>< 15. City of Chico plumbing permit. 16. Plot Ian and business license a ' r p approval from City of (see City for other requirements) " .:` 17. Planning approval for (A) Use: (B) Parking: ...... 18. 19. Improvements may be required. Contact Land Development Section DPW a Driveway permit (construction approval required prior,to occupancy) Le 20. 21. Pre-Inspectiona� for required .,.. Pre -Ins quest to Buildinggec. re Inspector (Date) Contractor's license information (No., Name Style, Classification) �~ w-_- 22. ... Certificate of Workmans Compensation,lnsurance ..... ? ...f......... 23. 24. Owner -Builder Verification (Given:towner ❑, Mail to owner ❑) .. Recorded copy of AgriculturahAcknowledgment Statement 25. Letter of signature authorisation .• . ............................... 26. t 27. When you issue the per it, process as follows: Mail to owner. Mail to contractor. Telephone 263 - d�and hold for pickup at OAd office. Deliver w/inspector. Copy of Haz-Mat,form sent Health Dept. Fire Dept. _Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: (Circle new item not checked above). 1. Index permit for above items No. 2. Additional items required: , I Contractor, designer, owner, was advised of above required data by—phone---mai [—counter by .date Contractor, designer, owner, was advised of above required data by_phone—mal l—counter by date Plans checked by Date Checked by Date Pl s approved by A41 Date Sets of plans on hold in File cabinett-11APfolder Copy—DPW — TO:, Building Department FROM: Encroachment Permit Section ' r RE: Driveway Clearance owner location AP # 1 Driveway permit /1"n' 12a-e'W has been issued for the above property. v 7k- lof� s ij6 ature date Building Department Environmental Health Sanitation Clearance r(, Owner. Location AP proved for: Sewage Disposal al for: earance O.R. for: e for r bedroom mobile Oome. Other an F Water Supply %J�r Water Supply Water Supply Date COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center Drive - Oroville, Cellfornla 95985 - Telephone: 918/538.7541 058-666-611 APPLICATAN Aka PERMIT ASSESSOR PAPICKL NUMBS - - - / / NDN BUILDING PERMIT .- OWNER I f I Q U M t(08 2(,3r TELEIPHON 3S SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDR SS a2 W OLC� r'44_5 036 CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $/A® C! Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING A EDESS A n •--�#IT•'- /�,'Roaal 0,eQ C. , Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO.SUBDIVISION 1 NAME feet &446.5 T PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF ❑ Duplex[] Mobilehomek Other sPECIFv Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S G 0.00ea TYPE OF WOR New❑ Addition /❑/� �Rf model❑ Utilities Installation❑ Other EJ Describe work: IV, NI - V -Cbg- 17-7 Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 1 10.00 Main service 100V OR 00 AMP ORSLESS 10.006 0 Main service EA. ADD'L 100 AMP 2.50 �t b CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): El am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification. ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.di OR ACDNS. (ACC. BLDGS. ,/z¢sgft NEW CONSTR ULTI.OUTLET NO N•tiE SID BRANCH CIRC ITS 2.50 ea POWER APPARATUS e (SINGLE OUTLET CIR. Ex. Occup( OR FIXTURES 20050t eALO3o FIXED APPLNS. Ex. OCCUp. OUTLETS (RESID.)REA.J 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 J�IQ 6 Misc. Wiring g 15.00 Permit Fee $ 3 (� WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to 4he W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed.revoked. Contractor MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling g Hood 3.00 Ventilation permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ I An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST TYPE TOTAL FEE $ �°� HAz. CUA PARK scHL FIo coF PAR PD 1 Ho. ISSUE This permit is hereby issued unser the applicable provi- sions of the Butte County. Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date No. • 5� 7. -T. -.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT �w- y .,X This set of plans and specifications MUST kept on the job at all times and it is unlawful tc make any changes -or alterations on same with- out written permission from the Department of Public Works, County of Butte. oArnanship Shall Be in NOTE. Materials &ni ed Good Practice �^ th A��°fC° with RSO for the S ea�f Codd � uality prescribed M• of a 'q ngplumbing Ut;�rm W� �}rical Cod ibe.IN °l p �P A setback of A ft. from the C. T\ property lines and a setback of C3 5o ft: from the road. centerline shall be clear of structures or equipment excePt 61 N for 2 eaveovethl oBN .. Alb �k v 4 1294-4 BUTTE COUNTY � BUILDJNG DEPARTMEN' APPR VED o� s12p, �ci T� FrF: ytir3it 7i i C{ bns zntsi :o tg,, '� �{i}'yY6ifttf i'1 ti ��1t, i^tril3 t� #5 #r_q 0. t nci tq4 x ;i hrtfi�tr7 Nati ;srIt atollf�a„�airw7a Ji1w tue fttz )fort � �FJ.f�rnnrr, +;o ►'�{ , d,;n t 0 iia .4 - r},`` der..,, ILI .4 - r},`` der..,, Return to DPW AGRICULTURAL STATEMMI OF ACKNOWLEDGEMENT FOR RESIDENTIAL DEVELOPMNT Section 26-8:1 of the Butte County Code, requires this acknowledgement be recorded prior to issuance of a building permit. 91-016809 .Rec Fee 5.00• The property described herein is adjacent r Check 5. 00 to land or included within an area zoned Recorded for agricultural purposes, and residents ' Official Records of this property may be subject to incon- County of ; veniences or discomfort arising from the i Butte ; use of agricultural chemicals, including, Candace J. Grubbs but not limited to herbicides, pesticides, Recorder and fertilizers; and from the pursuit 12:06pm 30 -Apr -91 XX of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All 'th-at real :property.*.situate in the County of Butte, State of California, described as follows: 11 �)� 6A7� °`�--- In�' d -L sol l J 0 to" Date: / PROPE Y O NEK-_\ ED State of On this the 30th day of APRIL 19 91 , before me, the SS. undersigned Notary Public, personally appeared County of ) IRIS ORUM nPersonally known to me.f7l Proved to me on the basis 0FFICIt�L SE of satisfactory evidence. Euna+••, A T K. VANEE to be the person{( whose nameij is NOTARYPUBLIC-CALIFORNIA subscribed to the within instrument and acknowledged that s e BUTTE COUNTY executed the same for the purposes therein contained. IN WITNESS �oN ` My Comm. ExptresJune20,1994 WHEREOF, I hereunto set my hand and official seal. Present A.P. No. C -- ) / Notary Public END OF DOCUMENT _. r ..