Loading...
HomeMy WebLinkAbout058-720-028COLUMBUS CARR W/S Big Bend Rd., 3 Mi. S of Hw Q0, Oroville �- 7 Permit # 4867-7p4 (Util. MH`) ELEC as' GAS SUPPORT STRUCTURE REQ .,dL COMPACTION TEST REQ._ V& zabeth Carr W/S 'g Bend Rd.,.,3 mi:S.of Hwy 70, Orovil contra S.S. Mobile Home Serv. aradis .Permit #4916=76 I � issued �` contra Norths.aa e Aluminum, Chico Permit #536+"=76B(2 avenin s/MH Perrot �k6002-76B(adcr'l ftg..- awning & arport/MHt)` 058=720-028 03-062 PENCE, RICHARD 5061 NOBB RD, OROVILLE INALi NEW_ _MH_PIyR1N1 FND EX SITE 19- 058-720-028 03-0725 PENCE, RICHARD 5061 NOBB RD, OROVILLE (2) OPEN DECKS LL TE BUTTE COUNTY INTER - DELIVER TO LAST PERSON NAMED NAME DEPT. DATE NAME DEPT. _�-- Q-�) COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 1 c� (Rev. 12/96) APPLICATION AND PERMIT 63—®7`� ASSESSOR PARCEL NUMBER 058-720-028 ZONING FR -10 BUILDING PERMIT OWNER PENCE, RICHARD 624-4880 TELEPHONE SO. FT. OCC. BUILDING VALUATION . OWNERS MAILING ADDRESS 5061 NOBB ROAD OROVTLLF, CA 95q69 60 0PEN 420.00 150 OPEN 1050.00 NAME CONTRACTOR'S ��LVM OW TELEPHONE TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER LENDERS MAILING ADDRESS Fireplace Total Valuation $1470.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 35.00 ARCHITECT OR ENGINEERS MAILING ADORES=_ Plan Checking Fee $ 23.00 BUILDING ADDRESS 9061 NORR 'ROAD OROVITLE CA Energy Plan Checking Fee $ $ PERMIT FEE $ 78,00 LOT NO. SUBDNLS IONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 6 X10 BACK DECK; 10 X 15 FRONT DECK Gas piping stem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home ISI GI W @20.00 PERMIT FEE $ ELECTRICAL PERMIT Filing Fee 20.00 Main Service ao.OR LESS 200AA OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. 1 ❑ 1 am exempt under Sec. Business and Professions Code for this reason Mein Service 200A TO 1000A 46,00NEW CONST. DWELLING OCCUP. OR ADONS. ( & ACC. BUDS. SO 3.5Q�; Pp CONST...MULTI OUTLET 97.50 POWER APPARATUS 8 SINGLE OUrLET CIR. EX. Occup. OUTLET OR FOCTUREs BAL @ 1. 0 Ex. Occup. OF'xuriErs REwss ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (rhe above sections need not be completed if the permit is for work of a valuation Of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall o �withcomplywith�thoserovisions. X Date �� �� �� Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or constructionof structures over 3 stories in h figBy/ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 78.00 HAZ D FEES IMP FLOOD CDF PARCEL I PD HD ISSU Thi*'�h�reby issued under the applicable provisions ofEach feesdhave beentions paid to do work ��� C�paQ PERMIT EXPIRES ON Def Receipt No 0 WHITE-D.D.S.-B.D. CAN Y- ESSOR PINK -INSPECTOR GOLDENROD -APPLICANT :V.t2196) ssZ==P/AR/e oraw�scas e ® iL t � 6p0.C7" COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - 'UILDING DIVISION 7 County Center D(rra , Oroville, Ca dornia 35965 ► Telephone 530) 538-154}�� P t lap✓ APPLICATION AND PERMIT (�� _�[ � *?EUAiT FEE P. Alb SRA arm. . x 7g" p TO a=_ !VT zwo cv I —= • O=um ( Duna on F=ww) I LaZ4 - I 1 Hama Fad eetT Fa::a s Fes I 2D.DD Pnw" FEE s Nbbb Hama lndwb5on Fee Energy hsp=bn Fee ; rm T FEEE $ �_ IWO permlt is heresy issued undat the appB=bla Prow els Of the Hinge Carmty Code and/or Aesol &mm to do work in3kal9d above for wh'rh fees have been pari 3y . Dste Re ptNa PERMIT D71RF3 ON sw+rre_w .. .. ...... e._• e•evrtne e�uCati`S'PECTrJR �OL6=uR47.iPPLICkNT 1• � Firm Fee 5 20.00 Pwmv FEB ca eamNM= M=ama AUWt= Pian Chmkir►a Fes a Enemy Pian Che -Ung Fee S . r ; Pmmm FE s =rim UM ra�2 ewP PLutimNG •PERMT Fi%g Fee 20.D0 3 3 dlC_ Eat Trip 7.0D USECFS TRucrim Solar or heat pump wshT heeler 23.0D 3F 0 Duplex D MobOahaane O Mar Water p'lpmg • 15.DD —%ch g= wElar heir or vera 15.DD TYPE CF WORK G=s plpog vv&t= 1 - s ou19Eft 1 s.DD 0 ?&w G Add3sm D Reamdd D UuTes 0 bsbiNCm 077t5-0 Swirl sewer 15.DD � NbbDe Homo W L2o.00 tie waa . m E=RrAL P—=RmIT Fiimg Fee 20.00 Mein SWvim o 2300 SNOW Low D 2c o T'® 2�'vo "T marm smize °m' T° 10=k 4LOD OR AMME AMML *?EUAiT FEE P. Alb SRA arm. . x 7g" p TO a=_ !VT zwo cv I —= • O=um ( Duna on F=ww) I LaZ4 - I 1 Hama Fad eetT Fa::a s Fes I 2D.DD Pnw" FEE s Nbbb Hama lndwb5on Fee Energy hsp=bn Fee ; rm T FEEE $ �_ IWO permlt is heresy issued undat the appB=bla Prow els Of the Hinge Carmty Code and/or Aesol &mm to do work in3kal9d above for wh'rh fees have been pari 3y . Dste Re ptNa PERMIT D71RF3 ON sw+rre_w .. .. ...... e._• e•evrtne e�uCati`S'PECTrJR �OL6=uR47.iPPLICkNT 1• � COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION -.7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET 05� � Zo OWNER: ASSESSOR PARCEL NUMBE Proposed Building Use: Counter Technician: Date: 3-13 Items required in order to apply for a permit. All boxes MUST be checked (�R marked NA in order to apply. ..Plot plans, 3 or 4 sets, signed,�y the preparer of the plans. 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Energy compliance design and supporting documentation in duplicate. ❑ 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed b the he en ineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The.permit will be indexed and returned to the plan review line-up when required items are received. Date Received By ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... ❑ 12. Hazardous Material Form............................................................................... _ ❑ 13. Other Remaining items needed to issue the permit. (May require additional plan review upon. receipt of the following items.) ❑ 14/ Fees as shown on the attached Schedule of Fees Due Sheet ..........................om ' OP6.Statement of Intent for Non -heated and A/C Buildings................................ Sanitation and plot plan approval from the Environmental Health Department in -ly 03 ❑ 17. City of Chico Plumbing permit......................................................................... ❑ 18. California Department of Forestry plan approval ❑ paid. Sent by: ...................... ❑ 19. Planning approval for (A) Use: _K(B)Parking: (C) Parcel Check: Q 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... Ei'212 . Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). 0.'22: Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... ❑ 26. Letter of Signature authorization.................................................................... ❑ 27. Recorded copy of Agricultural Acknowledgment Statement .................................... ❑ 28. Manufactured home utility clearance............................................................... ❑ 29. Existing violations and/or expired permits......................................................... ❑ 30. ❑ Grant Deed, ❑ M.H. Title/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: When issued Telephone and hold for pickup. I have beengijollhe above items and requirements for obtaining a building permit. Applicant: Date: 7>3I �3 Index permit application for the above items numbered 2. Additional items required Contractor, designer, owner, was advised cf the above data by Contractor, designer, owner, was advised of the above data by Plans reviewed by: Date: Structural reviewed by: Date: Note transfer by: Date: Plan Check Letter ❑ phone, ❑ mail, ❑ counter, by Date: _ ❑ phone, ❑ mail, ❑ counter, by Date: _ Plans approved by: Date: _Structural approved by: Date: �� � �- r� �� /,�� dim NoT3 Qct--- . V 966T AW — H S 9 O cc a .o X BUTIt COA 4 BUILDING d ma NTe APj gl, Q 9 rA, U. 8 ff-W I M uJ ia -V LT 7cz ui o w-lT� 9 % ~ r .. • m ~ CD _ _ - zc o O L�+-�d" 40 L-4 �m f•— �, c N Q4 IL LLJJ La co s g o LL b- a N•£ I... tv 2 �r► +- - }- x o d N r—t cm Q � L O Lk• 'NIW .99. 331&VA* a- Jas- 174;V • ��h�c� ..J a Z , Ld • Y v LU . , v ti 5 J cC S � Lu- IC a xeC v I � r p p p Lu :9 CC CJS O_' Q G C7 co 3 J 'I .c E• - L O Lk• 'NIW .99. 331&VA* a- Jas- 174;V • ��h�c� ..J •Z Ld }- , v ti 5 J cC Z Lu- xeC I � r L O Lk• 'NIW .99. 331&VA* a- Jas- 174;V • ��h�c� WRIII ffi Z.- r � ��t�l�l�Ob�AR ��a�pfi itYu�� II���ViOI� I- -7*q _.J - 1 i 1 r IL I o �Ropos� op�� i,l F,eon* Dec/< o BUTTE COUNTY 1BUILDING DEPARTMENT APp.;?ovF,, a 00 N LQ %; 59696 elu1ollle0'Blllnmo — enlip,elueO RlunoO 1 SHuom onand d0 1N3Wludd30 – 311(18 d0 Jl1Nnoo j ar,�,7Q�/aNd Sd�1� 7!//1/V_ -7d 16-48 7VOIDU •9NIOtRJ�I 'ib'NO�dla �ltfib34p' — ob - ick - 9 ,,,�.s,,•Nlw„{� .. � 1SoJ .bxb- I � ••• 1� a; ,��'�.• •::`�•q J:•• • � 2134211)-' i.gQ.�103X j S1-109/ Nlw,e Uzi X03 OA W07 uj w 1VJt11 - ' ®Ct. d h` TlIW.b 3Q '� Atli 'XUW'10) nWbj •11W Oct. .fir �t73d 210 co 3WOH 3119OW .17 El .1109 1g/� (01 .LiNb1? NJ. N MOH9 10N 1IU21dnd H (�Ik” --j �ilw I1 UO) M311\ AOL SWIJ .31 x.11 •XdW •''".8i► '21391YIb1S 211tl15 bl X.Z I4- - 2 L* n - - - — °lX.b 1 dl.J..C3 L 9N1100.:1 •NIW,, Ix„b) s �o Nry 1,,6 �rlW g � a� •�� *l31 . 15V3321d �1 � \ 9 r 12133(3 -)(VW „,1 t- ' � 3 -Ildbdbdn- z. 1X3 UJ QOUM k 1d `J @1 1 I'IQ 9N1100.:1 •NIW,, Ix„b) s �o Nry 1,,6 �rlW g � a� •�� *l31 . 15V3321d �1 � \ 9 r 12133(3 -)(VW „,1 t- ' � 3 -Ildbdbdn- z. 1X3 UJ QOUM k 1d `J @1 1 E.H. USE ONLY F402 Plan Attochod nC Floor Plan Attached 1 (, 7 vJ Sent to S.D. Ar / TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance -40 Owner Location AP# Plan Approved for: Sewage Disposes Water Supply: Public Private Wel Clearance for dwelling. Other / 0 4 t� 1) to --4' 6 Y- ) D Ly� Hold final for: Final clearance O.K. for: NOTE: Z2 iAISS. 3- N -N Environmental Health Specialist Date 8/96 ,L L)�utte county ,Environmental Health . �.� APPROVED Butte Coun4 Envital HI i nature Ae IL la s 0 �J s� 0 rj � Z � 0 C F W C. r EAVU 03.,S--7 Z 0-1 ���� NoW Pio--- RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 24 -Feb -2004 2004-0010095 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. RICHARD B. PENCE AND BRENDA L. PENCE REAL PROPERTY OWNER/LESSOR 5061 NOBB RD. MAILING ADDRESS OROVILLE BUTTE CA 95965 CITY COUNTY STATE ZEF SAME INSTALLATION MAILING ADDRESS, IF DIFFERENT SAME CITY COUNTY STATE ZIP SAME UNIT OWNER (if also property owner, write "SAME") SAME MAILING ADDRESS CITY COUNTY STATE ZIP UNIT DESCRIPTION BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE BUTTE CA 95965 CITY COUNTY STATE ZIP 03-0624 530 538-7541 B PERMIT N0. TELEPHONE NUMBER SIMATURE OF LOCAL AGENCY OFFICIAL DATE NONE DEALER NAME (if not a dealer sale, write "NONE") NONE DEALER LICENSE NO. FLEETWOOD 1994 SPRINGHILL / 3523 U MANUFACTURERS NAME DATE OF MANUFACTURE MODEL NAMFINUMBER CAFLRI7A/B 16575SH 52 X 12 & 50'8" X 12 RAD772047/48 SERIAL. NUMBER(S) LENGTH X WIDTH INSIGNIA/LABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER AP # 058-720-028 SEE ATTACHED HCD FORM 433(A) REV. 8/91 Order No. 103085 EXHIBIT "ONE" A portion of the Southwest quarter of Section 6, Township 21 North, Range 5 East, more particularly described as follows: COMMENCING at the West quarter corner of, said Section 6; thence along the North line of said Southwest quarter, North 89 ° 30' 36" East, 2,721.43 feet to the Northeast corner of said Southwest quarter; thence along the East line of said Southwest quarter, South 01 ° 04' 53" West, 683.00 feet to the true point of beginning for the parcel of land herein described; thence from said true point of beginning, South 44°,59' 00" West, 705.84 feet; thence South 89 ° 59' 58" West, 60.00 feet to a point on a curve concave to the West having a radius of 50.00 feet; thence along the arc of said curve, whose tangent at this point is South 00 ° 00' 02" East, through a central angle of 76 ° 50' 58" an arc distance of 67.06 feet; thence South 760 50' 56" West, 136.80 feet to the beginning of a tangent curve concave to the Southeast, having a radius of 130.00 feet; thence along the arc of said curve, through a central°angle of 450 08' 07", an arc distance of 102.41 feet; thence South 31 ° 42' 49" West, 91.30 feet to a point on the Northeasterly boundary line of the Big Bend Road; said point being on a curve concave to the Southwest, having a radius of 330.00 feet; thence along the arc of said curve, whose tangent at this point bears South 830 50' 13" East, through a central angle of 620 10' 13", and arc distance of 358.07 feet; thence continuing along the Easterly line of said road, South 21 ° 40' 00" East, 50.56 feet to a point which bears South 01 ° 04' 53" West along the East line of the Southwest quarter of said Section 6, a distance of 956.01 feet and South�88° 42' 48" West, from the true point of beginning; thence North 880 42' 48" East, 551.97 feet to the East line of said Southwest quarter and North 010 04' 53" East, along said East line, _956.01 feet to the true point of beginning. EXCEPTING THEREFROM all hydrocarbons and minerals now or at any time hereafter. situate therein and thereunder and which may be produced therefrom together with the free and unlimited right to mine, drill bore, operate and remove from beneath the surface of said land at any level or levels, 100 feet or more, below the surface of said land for the purpose of development or removal of all hydrocarbons and minerals situated therein or thereunder or producible therefrom. Assessor's Parcel No: 058-720-028 :.o BUILDING PERMIT NUMBER: 03-0624 Address or location of unit: 5061 NOBB RD., OROVILLE CA 95965 Legal Description of Real Property: AP # 058-720-028 SEE ATTACHED (x) Mobilehome/Manufactured Home () Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: RICHARD B. PENCE AND BRENDA L. PENCE Owner's address: 5061 NOBB RD., OROVILLE CA 95965 INSIGNIA OR HUD NUMBER: RAD772047/48 SERIAL NUMBER OR V.I.N.: CAFLRI7A/B 16575SH MANUFACTURER'S NAME: FLEETWOOD YEAR: 1994 OFFICIAL APPROVING INSTALLATION: �Qa DATE: 4-17-03 PHONE: (530) 538-7541 H.C.D. 513C FROM : R&B4ENTRPZE FAX NO. : 5308722919 May. 05 2003 11:21AM P2 STATE OF CALIFORNIA - DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT CERTIFICATE OF TITLE Manufactured Home Decal No: LAV7U33 �� MenufaCttlrot IDlName i Tnde Name Model DOM I DFS RV Exp. Date I 09534 FLEETWOOD HM INC SPRING HILL 3523U 07728/1894 09/0811684 - Serial Number Labetltn919Me Number Weight Length Width SPC SCC Exempt Use Type i CAFLR17AI6575SH I RAD772047 18,500• 52' 12' 04 SFD I LPT i CAFLR17BIGS75SH RAD772048 15.400 50' 8" 1Z' J _. . Pald ls9uad TOUI.Feee 21.0 Apr 08, 2003 $221.00 Addressee RICHARD PENCE 5061 KNOBB RD OROVILLE, CA 95965 tic' '" _;r i. .� -- .0 i• �Z'".:�, 7 11 11— .. :;: ..._. . r :., .'`Y ^c:' .,' di.�• ..:t-.�:;i.'x_1=::\:`.'s::i.e.;:i'^f.• 'i a^-' Y .;j'•' '`•�" , -' .. =Registered 0wner(s RICHARD P.EyI✓E BRENDA FSE CE :: =r` Joint TeniFiEs with_`Right of S,tpivorship 5061 KN¢BB R[1 __;'y T:,::• ; OROVIL! E, CA 9M5 Situs l%dtlress 5061 Kftl'OBB FIOAD _ OROVI "LE, CA''9596. - _ .. �. :::: 'V f. �,., .."'r!_ `.)i. "r --.f 4. ^y:: ,fes^... ._ ., i•i:r� :IG .{'� hr {,) !' `rte• ��. .:: i�•:_!. ::�:_: -, ,)...=lAr,_.'f:f _. �':.. f. _ .� . ai^- .� _-a: �;p�. .;t>;:1-- -��• ( � =', �!f'...'.. .,;a, :ilii:' , :., .,... �. - - � i,� •� �•` -'`�� 'dam 'vn ^_rte <F:_=-y�c..:'.., •:' •_,;i'r r.,tit�\• .. .4\ fV" ..... ........... .... :ice a :S _ . IMPORTANT THE OWNER INFORMATION SHOWN ABOVE MAY NOT REFLECT ALL LIENS RECORDED WITH THE DEPARTMENT OF HOUSING -AN D. COMMUNITY DEVELOPMENT AGAINST THE DESCRIBED UNIT. THE CURRENT TITLE STATUS OF THE UNIT MAY 13E CONFIRMED THROUGH THE DEPARTMENT. LyrN: 7906207 04082003. 322 RECORDING REQUESTED BY: Fidelity National Title of California Escrow No. 103085 -TT Title Order No. 00103085 When Recorded Mail Document and Tax Statement To: Mr. and Mrs. Richard B. Pence 8401 Montna Drive Paradise, CA 95969 a10GDZ-101055is4a Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 09:00M 22 -Oct -2602 GRANT DEED - SPACE ABOVE The undersigned grantor(s) declare(s) Documentary transfer tax is $74.00 ( X ) computed on full value of property conveyed, or [ ] computed on full value less value of liens or encumbrances remaining at time of sale, [ l Unincorporated Area City of Oroville I REC FEE 10.00 I TAX 74.00 1 MNU1){EN Is. H I I I I Andrew I Page 1 of 2 RECORDER'S USE FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Columbus Carr, surviving Joint Tenant hereby GRANT(S) to Richard B. Pence and Brenda,L.•Pence , husband and wife, as Joint Tenants the following described real property in the City of Oroville County of Butte, State of California: See exhibit "one" attached hereto and made a part hereof DATED: August 8, 2002 STATE OF CALIFORNIA COUN OF Butte L;-J"J'q'I ON q_ &-1. before me, olumbus Carr —jerri A a+in�, �a o personally appeared Columbus Carr personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. Witness my hand and official seal. Signature r E RUST1 Nn #1239620 U) ic . a - California Exp.•OCT24,2003 MAIL TAX STATEMENTS AS DIRECTED ABOVE ru-zl s (Kev //y6) GRANT DEED Order No. 103085 EXHIBIT "ONE" A portion of the Southwest quarter of Section 6, Township 21 North, Range 5 East, more particularly described as follows: COMMENCING at the West quarter corner of said Section 6; thence along the North line of said Southwest quarter, North 890 30' 36" East, 2,721.43 feet to the Northeast corner of said Southwest quarter; thence along the East line of said Southwest quarter, South 01 ° 04' 53" West, 683.00 feet to the true point of beginning for the parcel of land herein described; thence from said true point of beginning, South 440 59' 00" West, 705'.84 feet; thence South 890 59' 58" West, 60.00 feet to a point on a curve concave to the West having a radius of 50.00 feet; thence along the arc of said curve, whose tangent at this point is South 001 00' 02" East, through a central angle of 761 50' 58" an arc distance of 67.06 feet; thence South 760 50' 56" West, 136.80 feet to the beginning of a tangent curve concave to the Southeast, having a radius of 130.00 feet; thence along the arc of said curve, through a central angle of 450 08' 07", an arc distance of 102.41 feet; thence South 31 ° 42' 49" West, 91.30 feet to a point on the Northeasterly boundary line of the Big Bend Road; said point being on a, curve concave to the Southwest, having a radius of 330.00 feet; thence along the arc of said curve, whose tangent at this point bears South 830 50' 13" East, through a central angle of 620 10' 13", and arc distance of 358.07 feet; thence continuing along the Easterly line of said road, South 21 ° 40' 00" East, 50.56 feet to a point which bears South 01 ° 04' 53" West along the East line of the Southwest quarter of said Section 6, a distance of 956.01 feet and -South 880 42' 48" West, from the true point of beginning; thence North 881 42' 48" East, 551.97 feet to the East line of said Southwest quarter and North 01 ° 04' 53" East, along said East line, 956.01 feet to the true point of beginning. EXCEPTING THEREFROM all hydrocarbons and minerals now or at any time hereafter situate therein and thereunder and which may be produced therefrom together with the free and unlimited right to mine, drill bore, operate and remove from beneath the surface of said land at any level or levels, 100 feet or more, below the surface.of said land for the purpose of development or removal of all hydrocarbons and minerals situated therein or thereunder or producible therefrom. Assessor's Parcel No: 058-720-028 AFD WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE. OROVILLE CA 95965 IIII III III I IIII I II IIII II I IIIII I III ' 2003-001 5600 Recorded I REC FEE 10.00 Official Records I CONFORM 1.00 County Of BUTTE I I CANDACE J. GRUBBS I Recorder I ROSEMARY DICKSON I Assistant I Cheryl 11:28AM 12 -Mar -2003 l Page 1 of 2 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for cultural this property y � Sri purposes, and residents of p perty ma be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Buttc County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary fanm operations. All that real property situate in the Count), of Butte, State of California, described as follows: ACL ,r:�xH\ISIT 't bMe Ii Dntc:� i�J r"PRORTY V, \C CAA .Qb;r-V-S0-.0- State or California County of /3 On(l ) rt�117,2�?8 before me, lVJ ft3 �n�c� 'R. \✓C 1� 'LLQ / Y 00- br. . personalh• appeared 0 (Gl2Q r 6� IPS h C id �i'C'�yLdcC known to me (er- ►vcd to � personall�- within instrument and acknowledged to m�tt e/th�utcd the same i)to be the person(s)whose (s) whose name(s)d•4Varc subscribed to the that by �//thelr authorized capacity(ics), and 0r/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the Instrument. WITNESS my hand and official seal. Signa Seal: JUDI SUTHERLAND COMM. #1215301 �- NOTARY PUBLIC - CALIFORNIA a BUTTE Cou *Comm. Expires May 4, 2003 6 Order No. 103085 EXHIBIT "ONE" A portion of the Southwest quarter of Section 6, Township 21 North, Range 5 >"ast, more particularly described as follows: COMMENCING at the West quarter corer of said Section 6; thence along the North line of said Southwest quarter, North 89Q 30' 36" East, 2,721.43 feet to the Northeast corner of said Southwest quarter;thence along the East line of said Southwest quarter, South 01 ° 04' 53" West, 683.00 feet to the true point of beginning for the parcel of land herein described; thence from said true point of beginning, South 440 59' 00" West, 705.84 feet; thence South 89° 59' 58" West, 60.00 feet to a point on a curve concave to the West having a radius of 50.00 feet; thence along the arc of said curve, whose tangent at this point is South 00° 00' 02" East, through a central angle of 76° 50' 58" an arc distance of 67.06 feet; thence South 760 50' 56" West, 136.80 feet to the beginning of a tangent curve concave to the Southeast, having a radius of 130.00 feet; thence along the arc of said curve, through a central angle of 450 08' 07", an arc distance of 102.41 feet; thence South 311 42'49" West, 91.30 feet to a point on the Northeasterly boundary line of the Big Bend Road; said point being on a curve concave to the Southwest, having a radius of 330.00 feet; thence along the arc of said curve, whose tangent at this point bears South 830 60' 13" East, through a central angle of 621 10' 13", and arc distance of 358.07 feet; thence continuing along the Easterly line of said road, South 21 ° 40' 00" East, 50.56 feet to a point which bears South 010 04' 53" West along the East line of the Southwest quarter of said Section 5, a distance of 956.01 feet and South 880 42' 48" West, from the true point of beginning; thence North 88 ° 42' 48" East, 551.97 feet to the East line of said Southwest quarter and North 01 ° 04' 53" East, along said East line, 956.01 feet to the true point of beginning. EXCEPTING THEREFROM all hydrocarbons and minerals now or at any time hereafter situate therein and thereunder and which may be produced therefrom together with the free and unlimited right to mine, drill bore, operate and romove from beneath the surface of said land at any level or levels, 100 feet or more, below the surface of said land for the purpose of development or removal of all hydrocarbons and minerals situated therein or thereunder or producible therefrom. Assessor's Parcel No: 058-720-028 Description: Butte, CA Document- Year. DoclD 2002.55642 Page: 2 of 2 order. wam Comment: Butte County Departrnent ofDevelopment Services ADMINISTRATION' BUILDING' GIS' PLANNING 7 County Center Drive Oroville, CA 95965 (530) 538-7541 Telephone. (530) 538-2140 Facsimile February 11, 2004 Mr. Richard B. Pence Mrs. Brenda L. Pence 5061 Nobb Road Oroville CA 95965 RE: Request for HCD 433A (mobile home on a foundation system) Location: 5061 Nobb Road, Oroville CA 95965 AP # 058-720-028 Dear Mr. and Mrs. Pence: The State of California requires the 433A document to be recorded with the County of Butte Recorder's office at the final of your permanent foundation being installed. Please come by Butte County Department of Development Services Building Division, 7 County Center Drive, Oroville to pick up your 433A which needs to be recorded. The recorded 433A and supporting documentation must be mailed prior to. the State of California removing the mobile from state license rolls and the Butte County Assessor treating the mobile as real property. Should you have any questions concerning this matter, please contact Alice Mefford or Tammie Powell at (530)538-7541. Thank you. Sincerely Tammie Powell Plans Application Assistant NOTES t RESIDENTIAL PERMIT NO 058-720-028 V 03-0624 i PENCE, RICHARD ¢ 5061 NOBB RD, OROVILLE I NEW MH PERM FND EX SITE P t` THE HCD FORM 433A FOR THIS MH CANNOT BE RECORDED UNTIL ONE OF THE FOLLOWING HAS _ BEEN TURNED IN TO THE BUILDING DIVISION: _. (1) LICENSE PLATE(S) OR DECAL (THE INSPECTOR MUST RETREIVE). (2) STATEMENT OF FACTS (ONLY ON NEW MH' S), +INSPECTOR TO VERIFY SERIAL & LABEL #'S. t Lf r t i SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS, REQ. SPECIAL -INSPECTION ITEMS ti VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER r===------ --- -- I j OFFICE COPY Address 506 A "�� e 1 GAS Meter By nate ELECTRIC UUU Meter By Date JOB FINALED (Date) i Signature . In J=OK 0 = Not OK . = NotReadyable DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. El�ity; Location-Clearances-Grnd-/ /Amp -Concrete 7. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date 12. Card B-1 Date Card B-1 Date Card B -T Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks -Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector . 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. , 10. Exits; Insp.-Sketch 11. Cert. of Occupancy M Date Card B-1 Date +' Card B-1 Date Card B-1 Date Card B-1• ,v Date PER19ANENT END SYSTEM (ONLY) y1!ing Requirements -Setbacks -Easements f/t Ewings; Size -Spacing -Marriage Line _ Bloc 'mg - 4 g - r ash MH Test -Demand -Valve 6-'Slectricity; MH Test J_WetEP"fGIH Test and Sewer Connected Gas and Electricity Tagged w Xlts 40 -License -Decals r 11. Verify #'s with Office -. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 C -A. FL iZ P AS -7S s MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = Not OK - = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftq.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test Stucco Mesh -Drip Screed -Fd. Vents-UnderfIr. Access 12. Electric Underground Glazing Area -Glass Protection -Skylights -Plastic 13. Plenums & Ducts; Clearance -Material -Support -Ins. Shear Walls; Nailing -Bolts 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Brace Interior/Exterior Wall Panels 15. Access & Ventilation Insulation -Walls -Ceilings 16. Insulation 63. Infiltration -Walls -Windows Date Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 64. 17. Water Htr.; Vent -Access -Combustion Air Baffle 65. 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 71. Fireplace or Stove, Clearance -Hearth Date 72. Card B-1 Date Card B-1 Date 73. Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Elec. Outlets & Receptacles at Kit. Counter 24. Fixture & Transformer Clearance -Ins. Protection Garage Fire Door; Swing -Landing -Closure 25. Elec. Receptacles Spacing -Lights & Switches at Doors 26. Size Boxes & No. of Conductors Stapled Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 27. Romex Installed Close to Edge of Studs & C.J. Plb.; Elec. & Mech. Equip. Listed for Location 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water Elec. Receptacles in Garage (F.F.I.)-Romex Protection 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI Insulation -Foam -Looked in Attic 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral O Yes O No 32. Service -Riser Conductors & Ground Main Disconnect _ 33. Equip. Clearances Panels-Motors-Mech. Equip. 34. Clothes Closet Light -Shower Light -Spa Light 35. Smoke Detector 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings Date Water Well, Disconnect, Electrical, Plumbing Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Glass Protection 36. A.C. Ducts Insulation & Support Corrections from Previous Inspections 37. Vent Fan, Exhaust above insulation Gas Test -Meters Tagged, Gas -Electric 38. Condensate Drain & Overflow, Size & Grade Water & Sewer Connected -C/O to Grade -HD Approval 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet Energy Compliance Certificate -Other Certificates 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing cqr Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-UnderfIr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes _ 83. Following Instld./Drive D Yes O No/Walks O Yes D No/Planters O Yes D No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: w COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION " 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-754.f PERT L (Rev.12/96) APPLICATION AND PERMIT ( r,�� ASSES SO_P!ARC!r6 028 /V5V1 Z° 10 FR— BUfLDING PERMIT OWNER Pence Richard 624- TELEPHONE 674-4R80 SO. FT. OCC. BUILDING VALUATION . OWNER'S MAILING ADDRESS 5062 90BB RD OROVTUY, 95965 n/y� 1200 CONTRAC�TOORR'SS NAME OiYL\I:iLI TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER LENDER'S MAIUNG ADDRESS Fireplace Total Valuation Is (;l;- j'3M ARCHITECT OR ENGINEER LICENSE NO. —Filing Fee $ 20.00 Permit Fee $ 7i t M ARCHITECT OR ENGINEERS MAIUNG ADDRESS Plan Checking Fee $ y?Z-M BUILDING ADDRESS 5061 IRA Rt), .F Energy Plan Checking Fee $ .T $ PERMIT FEE $ 7f{[L LOT NO.S UBDNISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE W SF ❑ Duplex ❑ Mobilehome.A Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 1 S M Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installationx Other ,❑ Describe Work: it �% 1-4 1_6C 71 ( A/ 1M I^ Gas piping system 1 - 5 outlets 15.00 5-(� Building sewer 15.00 1 r M Mobile Home S I G I W 920.00 PERMIT FEE $ 6SJ (i � } ELECTRICAL PERMIT Filing Fee 20.00 Main Service E00V OR LESS 2o0A OR LESS . 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. NO. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. 4�1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00NEW CONST. DWEwNG UP. OR ACDNS. ( & ACC. BIDS. S° 3.5QFT: NEW NONR SID. MULTI.OUTLET 97.50 APPARA U d SINGLE OUTLET CIR. _ Ex. OCCu OUTLET OR FOCTURES BAL'':p Ex. Occup. I,E PR=JOEa 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) certify that in the performance of the work for which this permit is issued, I shall employ any person In any manner SO aS t0 become subject t0 workers'HAzIn�P,� compensation laws of California, and agree that f I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date , t 0 Signaa're of`Applicant - ❑*Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. X/ MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ TOTALFEE$ 349,00not EocCOUTYM11111*1 R FLOOD i► co�, 1 PApQ, I� pip P HD_ x ISVUE !� This permit is hereby issued under of the Butte County Code and/or indicated4abo`ve forwhich fees have B "� y PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date ME !21 t Dale Receipt No. WHITE-D.D.S.-B.D. —CANARY -ASSESSOR PINK -INSPECTOR `_ GOLDENROD -APPLICANT COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OFDEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE ?e�c=c-�OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. It you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. r) r(o V(" 5 c17-7 0e,k4cr ,✓f M1A,V) ` nev iuraz COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE t -4i _ ca 3 - y< Z`-/ OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact �ofi ediately. r s i Date �� 3 Inspector REV 10/92 y ' COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is complet&&' If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. r /-� - - - k / - 1I 'i l d-- .c. L Datet � Inspector REV 10 2 i 1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT, SERVICES - BUILDING DIV" N 7 County Cuter D;l::ve • Oroville, California 95965 • Telephone (530) 538 MI a -75 (Rev.12/96) APPLICATION AND PERMIT , `'� ASSESSOR PARCEL NUMBER 058-720-028 ZONING FR -10 BU11DINGPERMIT Pence Richard 624 - TELEPHONE 624-4880 80. Fr, OCC. BUILDING VALUATION . OWNER'S MAILING ADDRESS 5061 NO'3_ RD, OROVILLE 95965 1200 "R 64,800-00 CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER [Fireplace LENDER'S MAILING ADDRESS Total Valuation $ L ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 241 A4 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS ' Energy Plan Checking Fee $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome)V Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation/v Other Describe Work: Gas piping system 1 - 5 outlets 15.00 15.00 Buildingsewer 15.00 Mobile Home I S I G I W 920.00 PERMIT FEE S ELECTRICAL PERMIT Filing Fee 20.00 600v OR LESS Main Service 200A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class Lic. No. OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that 1 am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, twill do the work, and the structure is not intended or offered for sale. lY I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. OR ADDNS. a ACC. BLDS. so 3.5,s NEW CONST. MUBRANC .OUTLET NOµgES'. 1 7.50 POWER APPARATUS a sINOLF o�mET CIR. EX. Occup. OUTLET OR FIXTURES) BAS @': 0 Ex. Occup. o-E�°�A R=.) E 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wirin 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permitis issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation pf one hundred dollars ($100) or less.) v I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the orkers' compensation provisions of section 3700 of the Labor Code, I shall o ith comply with those provisions. X Date t �� / 0 > Signature o Applicant - wt>�ner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.Idl MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ �T r� TOTAL FEE $ 349.00 HOZ' D. FEES IMP X X FLOOD X CDF X PARCEL X PD X HD ISSUE X This permit is hereby issued under the applicable provisions of th utteCoun Code and/or Resolutions to do work in ate a for . icb fees have been paid. ,{ By 'v PERMIT EXPIRES ON ✓ et Receipt No. WHITE-D.D.S.- CANAR - SSES R PINK -INSPECTOR LDE OD-APPLICA _ ;;,, " ., .• 4t � a a .. �� r'�; � r r � � ,y ;� �i I' 'S V .,�/y�y[j�� � � �� 3 �.� 1 `+ M' l3 c i �✓{� ' z � 1 � � � � � � - �' � �J.J� - —L �' "`�� „hP�i• ,...�..-.. �-.-.. ...�.,,,�;,,l,�..,6� _ t•re.�µL��� a:•,;�,�,ew. -,. ,,,+,...y�.�3: �i':•>, r:.+�,...3.,,;,,:..w• COUNTY OF. 6UT-T EPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center. rive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET nAn N 5_ �� OWNER: ` ASSESSOR PARCEL NUMBER a Proposed Building Use: � `--.''�ounter Technicians-�, ��r' `� Date: � 4_3 Items required in order to apply for a permit. X11 boxes MUST be checked OR marked NA in order to apply. Plot plans, 3 or 4 sets, signed by the preparer of the plans. 2: Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Energy compliance design and supporting documentation in duplicate. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down foundation plans, all in duplicate. + ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. indexed and returned to the plan review line-up when required items are received. .1e Date Received ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ "lot plan and business license approval from the City of Biggs ...................................... ❑ 10. Letter of intent for non-residential buildings........................................................ ❑ 11. Detached Accessory Building Form filled out by theo ner..................................... ❑ 12. Hazardous Material Form............................................................................. ' ❑ 13. Other The permit will be By Re ain n items ed issue trand r e d ' jonal plan revi w upon r cei FR g ite n ,14. ees as sho non the attaches ue h t....5'. r� P U� .................. tatement of Intent for Non-ildings........................................... c�- �� 436. nitation and plot plan apprironmental Health Department in Qom' .. City of Chico Plumbing permit.......................................................................: ❑ 18. California Department of Forestry plan approval ❑ paid. Sent by: ...................... ❑ 19. Planning approval for (A) Use: o (B)Parking: ti (C) Parcel Check: ❑ 20. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... ❑ 21..,,Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... 4. Worker's Compensation Carrier and Policy Number ............................................. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... 2 .. Letter of Signature authorization........................................................ Recorded copy of Agricultural Acknowledgment Statement .........................�..' Ci ❑ 28. Manuf"ele earance.............................................. .............. ❑ 29ge Existipired permits .................................... ....... +........ . Q r/Statement of Facts, ❑ Letter from Legal e t H. rth : ssued and hold or PICKUP. I have been informe f the Wite s and requirements for obtaining a building permit. Appli ant: Index permit applicatio r e above items numbered: 2. Additional items requ eed Co designer, owner, was advised of the above dat Contractor, designer, owner, was advised of the above dak Plans reviewed by: 3— 7— D 3 Date: Structural reviewed by: Date: `Note transfer by: Date: 3-s = j phone, `k r ail ❑ by EY phone, ❑ mail, J�1 Plans approvedyb.. Structural approve -,dl Yellow: Building Division 3 1A I Plan Check Letter _Date: Date: Date_ I 10 -()ca BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM ;77 r Building) School District Building Department No. A.P. Number Property Owner Property Location/Address Subdivision Jurisdiction: = City I ®County Lot No. Residential Development I ✓) No of Living Mobile Home Addition/ *Supplemental to Units Installation Conversion Permit # '(No foundation inspection): €................................................................................................................... Sq. Footage 000 40 (Group R) Sq. Footage (Including Exterior )Roofed Are ,5 A4 Lo 5 Date School District Representative Paid by Check # 014 Remarks: Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm (Moor Plans reviewed by Scnool Uistrict Personnel) District Identification No. 030120 . District that i mi �) t4d^Ucool certifies (Applicant) / I ��\ J b --O 5✓,� 3-;30 1l (Street Address) (Phone Number) 001UI•II-e. (City) (State) (Zip Code) has complied with the requirements of Resolution No. l�5740 by payment of $ representing 20 O square feet. AB 2926 S FULL MIT ATION S School District Representative Paid by Check # 014 Remarks: Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (10/98)dmm d �,WphK t'> ;"i 1H�Y p,te',f'fh'S+�°ti.'q E.H. U3U OtdiY 1 'Plot Pian AKethad a . 0 Floor Pian Annachad "' •r} Sant So 8.0. ! TO. Building Department FROM: . Environmental Health _ SUBJECT: Sanitation Clearance O ,, Location AP# Owner Public ` Private. Well\ Plan Approved for: Sewage Disposal-. Water,Supp'(y Clearance for . dwelling.' Other / d �L Lha-��',%� 1 _ ] B /t �/i//VI. /9lYl n J�� al -:for r t ~Environmental Health "Sp a s ! , o f }� �t� +' ' 1 i 1 tF.7,. }, t_ rf.�. ii• f _t_ }.- rF,at5Ne. v Kft tr x. t It, tAl Date eclallst y 1) +41 >•4 ). L'U 7�J 1 `�, tij nt�S`f ,y i-� r�a f ,.-fr j.y J4 �'' ;. ' riSy :. ' rf s , �/ i, wxx � y � `�`� tom' sJ�y �.w sg r• It APPROVED Butte County AppROVED - Ic IP--------- - - - ( AL ZiA It L -7! Li o3s - -7 0— Per-)- boo APPROVIR 'a Butte County * EnvironIn I Cta14�1 " i ov) I 3 ' ��• Unr fA Tj ko APPROVED '0 Butte Coun f Envc Z � ental ®alth pct . - to Ile FL ,110Pill ME 2A 1 HER !•;'VER D>_VD. FLEE D® Sl lncreSt Series .Model 35230 ORoviLLE, CA 95965 • 3 Bedrooms 2 Baths • 1,200 Square Feet (530) 532-3301 ! - ! .FREEZER ! 1 --1 �❑ I-- —� 3 O - O SPACE OR _._ .0 S Tllnl'INK. D F t t ;_ DINING mfir,_ ... _ SNACK AREA BATH- 1 13EDROOM #2 . -_�---! r- - saR 1r-6"xfl'-4" �1= ! I 10'-4"X 11-4" BATHS SHELF- i - - O _! »= WALK -W _I ! L.CLo5ET_ 1 _____— _-- PANTRY 23'-4" _ 01'T WALK-IN BAY5 MASTER. iBEDROOM #3 BEDROOM VYING ROOM i21-0.. X 11'-2" n1o'-to"x '-2^ 15'-6" X W-14 ENTRY G.! CLOSET OPT - 0❑ 1-- --- CORNERI3AY 00 CLOSET CLOSET _ i I OPT DEN PANTRY (TOOK ' SHELF - ' ALT. KITCHEN OPT.. DPT. ANGLED RECE55ED ENTRY RECE55ED ENTRY Note that square footage is measured from exterior wall to exterior wall, and is'an approximate figure. Length indicated in floorplans is floor length only. Renderings and diagrams are meant to be representative and, in keeping with Fleetwood's policy of constant updating and improvement, may vary from the actual home. Al dimensions are, nominal. Ask your retailer for specifics. (Add four feet to arrive at transportable length.) PRICES AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 01996 SU/17/NOV02 16 0- 4c.44rAt i J aff- Ild- SHELFBARBAO L.t_}rI WALK-IN.. _ _ - 1 I+ -I cL05E'f._ .. -- --- _-- PANTRY j 23-4 OPT WALK-IN BAYS, MASTER LIVING ROOM BEDROOM #3 BEDROOM 21'-o"XW-2 i 10'-10"X.1'-2" .15'-6"X n'-4" ENTRY CLOSET. OM -❑' --- 1-4 CORNER BAY - CLOSET - CLOSET � OPT DEN 12'-10" X W-2" PANTRY BOOK- SHELF ALT. KITCHEN OPT. OPT. ANGLED RECESSED ENTRY RECE55EV ENTRY - Note that square footage is measured from exterior wall to exterior wall, and is an approximate figure. Length indicated in floorplans is floor. length only. Renderings and diagrams are meant to be representative and, in keeping with Fleetwood's policy of constant updating and improvement, may vary from the actual home. All dimensions are nominal. Ask your retailer for specifics. (Add four feet to arrive at transportable length.) PRICES AND SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. ®1996 SU/17/NOV02 2. Assessor's Parcel Number: 3. Installer's Name: R \ 4. Is the site currently under permit? YesK No[ J Permit No. 5. Is the site an existing site? Yes]No[ ] (If yes, furnish two plot plans). 6. What is the electrical rating of the mobilehome? %b d Amperes. 7. What is the mobilehome site circuit breaker rating? %D d Amperes. 8. What is the electrical rating of the mobilehome site? / O- Amperes. 9. Is the main service remote from the mobilehome site? Yes[ ] No[ ] If it is, what is the rating 24J-0 Amperes. 10. Is there any othert`,,,-lectric load to be served by the mobilehome site electric service (i.e. well, garage etc.)? Yes[ ] No[ -I If yes, please identify the load and size: a) The mobile home site: Load- Amperes - b) The main service: Load- Amperes - 11. Type of gas service at mobilehome site: Natural[ ] Propane[vf'/None[ ] 12. Size of as pipe at the mobilehome site from the meter or tank: inches. 13. What is the gas pipe length from the meter or tank to the mobilehome?_W 14. What is the mobilehome gas demand? B.T.U.* *(This information is not required if the pipe length is less than 6 feet on natural gas or less than 50 feet on propane). THE OTHER SIDE OF TRIS FORM MUST BE COMPLETED IN ORDER TO PROCESS THIS,PERMIT APPLICATION BUTTE COITy YMUM DEPAMNEW May 1995 PP0 ' 8.5 Mobilehome Manufacturer: Manufacture Year:. f g S If other than single wide;'furnish Setup Model Number: Width: (ft.) Length: 5 Z 5,o(ft.) Tagalong or Expando Size = �-� O On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural setup sheets. FOOTINGS: Wood pressure tre ed or foundation grade[ Other: SUPPORTS: Concrete block[✓,Other: Provide Tie Down Specifications for all Mobilehomes: Pier Footings Sizes and Location SINGLE WIDE MULTI -WIDE Line 1 e I Line 2 IL ine 2 Main Beam .................................................................................Lme 3 Line 2 Line 1 Line 2 ................................................................................Main Beams Line 2 Line 1 e3 rag or Triple ine 4 .......... ' el Line 1 Piers: Size minimum: r ixV Spacing maximum: I V` From ends -maximum: ` Line 2 Piers: Size minimum: ),] x -2m]- Spacing 2].Spacing maximum: 1 ^1 ` o ` From ends -maximum: ` Line 3 Roof Loads: z4� Size minimum Location (from front): Line 5 Roof Loads: Size minimum: Location (from front): Line 1 Openings Size minimum: [ 2,11 x [ i y]. Each side of openings with width over: I z, ` (A D Line 4 Piers: Size minimum: I X.F ]. Spacing maximum: ` From ends -maximum: ` vt�a.� a yx �u3,a a�{x3o a � v ,z scan &I 4OVE COUNTY OVER @ULM DEPA. . UP Apppo�tD i f . DOhELE WIDE r1EFiI!;G 1'�ORt.SHEET eos _ - :DE L: 35Z' 3 Z—PSF ROOF IOJED PIRh'T� 1. -7_ S/l/ Limi fc ` SEE PFRIMITER PIERING SU •.D'£ MDU'RIMIMSTRELE .f r -c — -- r —s — t- _— — t— -- -t . — •*•— SEE t; ATIAG'Lit:E PIERIt.G uta' FRONT OF* SEE PERIMETER UtiIT FIERING REOUIREMENTS TAE LE • . I%011 SEE FIRING PLMI, AND PIER LOAD CRPACITY M WINGS FOR RtUJIR=IlENTS-OF MAIN - F,ikII. SUFPORT CAF/.CITYAND FOOTING SIZE. • MOM* LIRE FIERING T:.EIE• ?. E E c j'.: IAalc: F::T I:T R.1B7.2h� 1•. Mfr+ �R 3i.� 1'.'iE�,�S tttt P%lE%,1; STFI P.'11m; %ts 1, a . •- 1Ga :�:'.S tT :nom': i.?:T i:ST i:+5, f QST P:ST FJR LOAD tcPcCtTY1%LFS. Z$SG yr;2v 3300 3`736 078 WNlW-JN.cif iIECE F�•�TI►:3 J IE Zy X 18 12-14 xag I ?_4XZ?_ Z4 X2y 2-4XZO y M I,- L4 Z9"q 1. C 11 E: F =,orl S`ZES be cel Ors iDJJFS= If S07.1 cor ditio%t diger See ihE PIEI Loid CE p DLA► wav; ins G' the How Te:hrj.m; In`IEIli Von W naIf oT fn01n S et m1wht-M. PERIMETER FIERING FECU'•REMENIS TLFLE. =:D LSD: =S ►E WJCLt• F.Dt,DS•:iEti1':t,::• . JAM E; SiU:11� i.l E C•' i'::':%,:S 14f:D AND t• • ; •'• 1 f: C,LD FIMFL1, S 1': , C,..'E r Cr f LOOR • -FcoNss, i F;15TS-AT ni. -- EE.SE'.•.•tIL-WHEN - -; `�-c•1 r•Es•t t�• . Y • -• - _ • .. ... .._-. _-----.._- . -. =_:E114tEt.S".UI:E. ALE FRDI : fF.Di:7 i1F UUIT. MAIN BEAM FOOTING CONFIGURATIONS AND SPACING 12 WIDE - MULTIPLE SECTIONS SECTION "A" { {i --- I 1 I SECTION "B" i :i --- +_____t__._i.. ___t i; SPACING VARIES SECTION "C": SEE TABLE ' - 'a ■ MAIN BEAM FOOTINGS These tables determine the footing pad configuration and footing spacing along the main beams of the section(s). Refer to pages 13 and 14 for footing pad configuration details Review the table that indicates the footing type you are going to use. Refer to page 17 for the procedure on using the tables. 8" X 16" X 4" CONCRETE FOOTINGS � Roof MAXIMUM MAIN BEAM FOOTING SPACING (In Feet) y Live Dbl. Pad Footing Triple. Pad Footing Two Dbl Pad Ftng. v a o Load (W Main Beam Size Main Beam Size in Beam Size w (pso 8" 10" 12" 8" 1 10" 12" 8" 10" 12" Size 20 3'-6" T-6" 3'-6" 5' 5' 5' 7' 7' 7- 1000 30 40 3' 3' 3' 4'-6" 4'-6" 4'-6" 6' 6' 6- 30 3' 2'-6" 2'-6" 2'-6" 4' 4' 4' 5'-6" 5'-6" 5'-6" 1500 20 30 5' 5' 5' 7'-6" 7'-6" 7'-6" 8' 10' 10' 20 40 4'-6" 4'-6" 4'-6" 6'-6" 6'-6" 6'-6" 8' g' 91 30 4'-6" 4' 4' 4' 6' 6' 6' 8' 8' 8' 2000 30 6' 6' 7' 8' 10' 10' 8' 10' 12'- 20 30 40 5'-6" 5'-6" 6' 5'-6" 8' 8' 9' 8' 9' 8' 8' 8' 10' 10' 12' 11' 3000 20 8' 8' 10' 9' 10' 9' 8' 8' 10' 12' 8' 10' 12' 20 30 400 8' 8' 8' 10' 10' 10' 12' 8' 10' 12' 40 8' 8'-6" 8'-6" 8' 8' 10' 12' 8' 10' 12' 8' 20 8' 10' 12' 8' 10' 12' 8' 10' 12' :400JO30 12' 8' 10' 12' 8' 10' 12' g' 10' 12' 11'-6" 40 8' 10' 10'-6" 8' 10' 12' 8' 10' 12' 2" X 12" X 24" WOOD FOOTINGS � Roof MAXIMUM MAIN BEAM FOOTING SPACING (in Feet) Roof Live Sgl. Pad Dbl. Pad Triple Pad ca N Load Footing Footing Footing O g (pso Main Beam Main Beam Main Beam 0 Main Beam Size Size Size Size Size 8 10" 1 12" 8" 1 10" 1 12" 8" 1 10" 1 12" 1000 20 T-6" 3'-6" 3'-6" 7' 7' 7' 8' 10' 11' 10' 30 3' 3' 3' 6'-6" 6'-6" 6'-6" 8' 9'-6" 9'-6" 10' 40 2'-6" 2'-6" 2'-6" 5'-6" 5'-6" 5'-6" 8' 8'-6" 8'-6" 1500 20 5'-6" 5'-6" 5-6" 8' 10' 11' 8' 10' 8' 8' 10' 10' 30 4'-6" 4'-6" 4'-6" 8' 9'-6" 9'-6" 8' 10' Al2' 10' 40 4' 4' 4' 8' 8'-6" 8'-6" 8' 10' 2000 20 30 7 6'-6" 7 6'-6" 7 6'-6" 8' 8' 10' 10' 12' 12' 8' 8' 10' 10' 12' 12' 10' 10' 40 5'-6" 5'-6" 5'-6" 8' 10' 11'-6" 8' 10' 12' 3000 20 30 8 8' 10' 9'-6" 11' 9'-6" 8' 8' 10' 10' 12' 12' 10' 12' 8' 10' 40 8' 8'-6" 8'-6" 8' 10' 12' 8' 10' 12' 20 8' 10 12 8' 10' 12' 8' 10 12' 4000 30 8' 10' 12' 8' 10' 12' 8' 10' 12' 40 8' 10' 11'-6" 8' 1 10' 12' 8' 10' 12' 16" X 16" X 4" CONCRETE FOOTINGS Roof MAXIMUM MAIN BEAM FOOTING SPACING (In Feet) Live Sgl. Pad Dbl. Pad Two Dbl Pad C H Load Footing Footing Ftng. v 8 (psf) Main Beam Main Beam Main Beam 0 Size Size Size 8" 1 10" 1 12" 8" 1 10" 12" 8" 10" 12" 1000 20 3'-6" T-6" 3'-6" 7' 7' 7' 8' 10' 12' 30 3' 3' 3' 6' 6' 6' 8' 10' 12' 40 2'.6" 2'.6" 2'-6" 5'-6" 5'-6" 5'-6" 8' 10' 11' 1500 20 30 5' 4'-6" 5' 4'-6" 5' 4'-6" 8' 8' 10' 9' 10' 9' 8' 8' 10' 10' 12' 12' 40 4' 4' 4' 8' 8' 8' 8' 10' 12' 2000 20 30 7' 6' 7' 6' 7' 6' 8' 8' 10' 10' 12' 8' 10' 12' 40 5'-6" 5'-6" 5'-6" 8' 10' 12' 11' 8' 8' 10' 10' 12' 12' 3000 20 30 8' 8' 10' 9' 10' 9' 8' 8' 10' 10' 12' 12' 8' 8' 10' 10' 12' 40 8' 8' 8' 8' 10' 12' 8' 10' 12' 12' 4000 20 30 8' 10' 12' 8' 10' 12' 8' 10' 12' 40 8' 10' 12' 8' 10' 12' 8' 10' 12' 8' 10' 10' 6" 8' 10' 12' Multiple Section Installation Manual for WZ-1 Page 20 �J` Bt,0�11iG � PA S. �PPRO�ED z 6 n 6 A NOTES/LEGEND C3) 7 A OPT 5 CIRC 3 7 cis 0 OPT OPT a 0 DEN 142.7 SQ.FT. 7 APPROVED rj PFS Corporation Suncreist, MAM 3623U NTRY Madison - 4 I �j 7116/01 HUD Manufactured MAWM 5 1/-4# Illf Home I Den N.T.3 Construction & 13/-4# f s e t Safety Standard . Mark Lively 7117/02 BCHRM Ft n O is 5 z 6 n 6 A �r� Lr NOTES RESIDENTIAL PERMIT NO. x058-720-028 03-0725 PENCE; RICHARD i t 5061 NOBB.RD, OROVILLE (2) OPEN DECKS SPECIAL CONDITIONS SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER 1 f ;JOB FINALED (Date) Signature CHECKED BY J=OK 0 = Not OK r = NotReadyable DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Date 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) Footings; Size -Spacing -Marriage Line 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 3. 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or/ /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance Electricity; MH Test 10. Roof; Shthg-Roofing 6. Water; MH Test Ext.; Steps -Doors -Landings Date 7. Card B-1 Date . Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks -Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line License Decals 3. Gas; MH Test -Demand -Valve -Connector 11. 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector Pool Structure; Steel -Connections -Thickness Dead Men -Lining 6. Water; MH Test -Regulator -Connector Date 7. Water and Sewer Connected -C/O to Grade -HD Approval Card B-1 8. Gas and Electricity Tagged Card B-1 Date 9. Tie Downs -Type -Installation Cert. 7. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 1. Zoning Requirements -Setbacks -Easements 5. 2. Footings; Size -Spacing -Marriage Line 6. Carports; Windows -Doors 3. Blocking Electric 4. Gas; MH Test -Demand -Valve 9. 5. Electricity; MH Test 10. Roof; Shthg-Roofing 6. Water; MH Test Ext.; Steps -Doors -Landings 7. Water and Sewer Connected 8. Gas and Electricity Tagged Card B-1 Date Card B-1 9. Exits Card B-1 Date Card B-1 Date 10. License Decals 1. Setbacks -Easements 11. Verify #'s with Office Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining Date Elec.; Receptacles and Lighting, Distance-GFI Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils-Size-Depth-Spacing-Conhectors-Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric B. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries_Terminals-Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures -Panel boards- Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date, Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = Not OK = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 15. Access & Ventilation 60. Shear Walls; Nailing -Bolts 16. Insulation 62. Insulation -Walls -Ceilings Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 68. G.F.I. & Bath Fixtures & Tub Access -Spa 20. Shower Pan; Test, First Floor -Tub Access 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 21. Test Tub & Shower, Second Floor -Tub Access 70. Stairs & Rails 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance Date Card B-1 Date Card B-1 Date 76. A.C. Duct in Garage -Damper Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 78. Plb.; Elec. & Mech. Equip. Listed for Location 24. Fixture & Transformer Clearance -Ins. Protection 25. Elec. Receptacles Spacing -Lights & Switches at Doors 81. Guard Rails & Deck Construction -Post Caps 26. Size Boxes & No. of Conductors Stapled 27. Romex Installed Close to Edge of Studs & C.J. 83. Following Instld./Drive 0 Yes 0 No/Walks 0 Yes 0 No/Planters O Yes O No 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral 0 Yes 0 No 89. Ventilation Throughout House 32. Service -Riser Conductors & Ground Main Disconnect 33. Equip. Clearances Panels-Motors-Mech. Equip. 92. Gas Test -Meters Tagged, Gas -Electric 34. Clothes Closet Light -Shower Light -Spa Light 93. Water & Sewer Connected -C/O to Grade -HD Approval 35. Smoke Detector 95. Address Posted Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor 0 Yes _ 83. Following Instld./Drive 0 Yes 0 No/Walks 0 Yes 0 No/Planters O Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY 05 BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 Grounty Center Drive • Oroville, California 95965 • Telephone (530) 538-7541n ERMIT o "" (Rev. 12/96) APPLICATION AND PERMIT (��_ / L� ASSESSOR PARCEL NUMBER 058-720-028 ZONING )''i2-10 BUILDING PERMIT OWNER 624-488060 TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS EN 420.00 150 OPEN 1050.00 CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTORS MAIUNG ADDRESS CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $1470.00 ARCHITECT OR ENGINEER LICENSE NO. Fling Fee $ 20.00 Permit Fee $ 35.00 ARCHITECT OR ENGINEERS KMUNG ADDRESS Plan Checking Fee $ 23.00 BUILDING ADDRESS 5061 NOBB Ail n Energy Plan Checking Fee $ PERMIT FEE $ 78.00 LAT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 6 X10 BACK DECK; 00 X 15 FRONMECK Gas piping stem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home ISI GI W1 @20.00 PERMIT FEE S 414. ELECTRICAL PERMIT Fling Fee 20.00 OR LESS Main Service 200, OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POWER License Class Lic. No. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service 200A TO I 000 46.00 NEW CONST. DWELLING OCCUP, OR ADONS. ( a ACC. BUDS. SO 3.50FT. NON -RID. MULTI -OUTLET @7,50 APPARATUS 8 SINGLE OUTLET CIR. Ex. OCCU OUTLET OR FIXTURES e20 Ex. Occup. DFUTLEEDTS RL. °� 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE S MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) /I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall orthwith comply with those provisions. c^ t X_ Date 111�� 6� Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 78.00 HAZ. D. FEES I IMP I PD I HD I ISSUE This permit is hereby issued under the of the ,Butte County 'Code and/or indicated above for which fees have f / ey N PERMIT EXPIRES ON applicable provisions Resolutions to do work been paid. Date Date ReceiptNO. 51/9W17/9 7F i% WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT 1 REQUEST FOR INSPECTION Loca�ion • Owner: Call L] Phone: Permit No. V 16 2cr. Contractor: BLDG. PLUMB/MECH ELECTRIC M.H.I./M.H.U. PRE - INSPECTION Form Rough Rough Fnd/Ftg Frame/Underfloor Top Out Temp. Service Job Status Stucco Lath Stucco Brown Woodstove Gas Pipinglrest Temp. Gas Sewer Piping Main Service Underground Well Circuit Corrections Final Permit Renewal Verify Utilities Ex Mobile Site Brace Panel Water Piping POOL Insulation Shower Pan Nailing Demo Gunite Bonding Corrections Corrections Corrections Light Niche Ready for Final Final Final Corrections Final Inspec. on: Date: Comment: PRE -INSPECTION REPORT' OWNER All DATE: 3 3 LOCATION: . �� i� C� A.P. CONTRACTOR •_ Q -n PRE-INSPETION FOR E M ZONING: DATE TO INSPECTOR: -� .� PERMIT HISTORY:( ) NONE ( ) AS FOLLOWS: BUILDING INSPECTOR'S REPORT BaldlnB Description: Electric: CommerciaWsage: Residential/# of Units: Cun early Occupied Abandon amt Yes_No Electric currently On ' Off Condition of Electric Gas: Natural. Propane---Lz-� None Obvious Problems: Sanitation: Currently On Plumbing Working Well Working Potable Water /70 0J 1� 4, ACTION RECOMMENDED: bSSUE: HOLD FOR Inspector. �75— Date Sketch buildings on reverse and indicate location on, p'roper COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION ` < 7 County Center Drive & Orovi[te, CPOOmia 95905 • Telephone (530) 538-1541 P:-:P1AT !J0• < APPLICATION AND PERMIT :v.121967 " BUILDING PEWIT u P 6. '77 �s el SQ. FT. OCC. BUILDING VALUATION s: �. �ecn�-earn sce� :r�m►an� ( -�rSpR-1965 Mot= {C7MEMS Firepfa� � � rwass low val aason �oRENMEM s FiTho Fee 5 20.00 pwmlt Fes 4 1" L' G 61 m earn s uaca+a �n�as Plan ch=ldnq Fes s 2 ;2 C' aaamu�mma�ss -�` %� L) n .-- U_ % gy Pian Chug Fee s PEPArT Fm �rers se rr,�a x4r PLI�6QSIWG ,pER i T FFmg Fee 20.00 Ead; Trap 7. D D USEOFSTrRU=RE Solar or heel pump waiel hem 23.OD �F U Duplex D 6bb0aharnsMar Ws:r piping Is. Do — sP r Each gn wart heir or vert IS. DO � j TYPE OF WORK Crs pwmg ! - s oaAw= 15.00 7 j !m G A=C3 Rmcdd O us= D bdasr= 01her f] __ -%Afmg sewer I S.DD - L f / IJbbile G W @120.OD De=Tibs Word C/1' -- PEn" Fm S ELECT IC L PEW T Fi%,g Fee zD.oD snm► 70 sem% 4SOD eaLM o (.7SD �.O o su0� EX a LOD ?C i' FEE PUD Tear setvoa ZLDD fJbble Haase Facmes 2:ROD SCR $ f%-- 'Allrbg MDD PER Aft(T Fig S OTM.• � XF-C"HICAL PERBMT FMig Fes 2D.00 HesFmg H=d 6.50 1'mIsm = 4 T ` PF..RUTT F.=k s I1bbh Hmns bsstMon Fes = alwrw bsspe�on Fee S L L, F EEE $ 3 ' G 6 "�/3 MM TO De� � CO Fra V� FLa70 CDP PM=PD 1� C TWX pmnd Is her bar Issued under The appf=bls prodsimns of lhe Bulte emu* Code and/or Ammohdnrs to do work indicabd above for whi-h fees have been paid. By . Dam Re�pWo, PERM? ExmEs ON �..+.+� � . - .., �.... vr_e revrene oue.nSPeGi7R c'o0_O-�1RDD•IPPL!^,-AHr �� COLUMBUS CARR W/S Big Bend Rd., 3 Mi. S of HW'v 70, Oroville -� t # 486 ��7�- 7� Permit 7-74 (Util. MH) i --GAS SUPPORT STRUCTURE REQ.,,710 COMPACTION TEST REQ, IUB 'zabeth Carr �- 4 W/ ig Bend Rd...,3 mi:S.of Hwy 70, Orovil contr: S. Mobile Home Seryaradise. s Permit #491 ryMHI �I1 . e .,-,issued Q' contr: Norths, ate Aluminum, Chico T+ Permit ��536, -76B(2 awnings Permit* 6002-76B(add' 1 ftg,. - awning & ea rport/MH) ri ' � �� ` .. •. � .. - - • t�� `" �, fes.. xze-l- i -s -z' / y /-77Zf) IV 7 -�f k / 4 6� 75 S'j) J_ PERMIT NO. 6002-76B 4�'`• PERMIT EXPIRES OWNER Columbus Carr CONTR. owner LOCATION (A.P. 62-45-28 Ne Side Big Bend Rd., 3 mi. S.of Hwy q0, Oro. All, i� yyyy! "Q 'y' f 1 � • g } Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Temp. Gas Serv. Called PG&E JOB - t FINALED • (Date) i (Signature) . 1 ( • 'S I C J_ PERMIT NO. 6002-76B 4�'`• PERMIT EXPIRES OWNER Columbus Carr CONTR. owner LOCATION (A.P. 62-45-28 Ne Side Big Bend Rd., 3 mi. S.of Hwy q0, Oro. All, i� yyyy! "Q 'y' f 1 � • g } Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Temp. Gas Serv. Called PG&E JOB - t FINALED • (Date) i (Signature) . 1 ( • Setback Forms Main Bldg. Footings Stemwal I Slab Piers Garage Footings Stemwa I I Slab Carport Footings Slab Patio Footings Masonry Walls Reinf. Steel Bond Beam Framing Stucco Mesh Scratch Brown Finish Interior Lath Door Closer DATE COUNTY OF BUTTE — DEPARTMENT OF.PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Firewall Soil Piping Parapets 1st Floor Restroom Finish 2nd Floor Windows 3rd Floor Siding To out Roof Sheathing Water Piping Roofing Sewer Fdn. Vents Fixtures Garage Vents Insulation Water Htr. Heaters Prov. for physically handicapped Conformance of ex. structure Final Appliances Gas Piping &Test Temp. Gas Sanitation FIREPLACE Final Footing ELECTRICAL Throat Rough Final Fixtures FIRE SPRINKLERS Motors Test Water Htr. Final Subpanels MECHANICAL Grd. Fault Prot. Heating Service Cooling Temp. Pole Ducts Underground Ventilation Permanent Final Final REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) µ I. PERMIT NO. 5361-76B ) PERMIT EXPIRES d' S `OWNER Columbus Carr ICONTR. Northstate Aluminum, Chico LOCATION (A.P. 62-45-28 ) W/S Big Bend Rd.,3 mi.'S.of H2y 70, Oroville r rV'•' i� 1 s i I� Temp. Power Pole_ Called PG&E _ Temp. Elec. Serv._ Called PG&E Temp. Gas Serv. Called PG&E ` JOB FINALED (Date) (Signature) I COUNTY OF BUTTE — DEPARTME14T OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows" 3rd Floor Stemwall Sidinq To out Slab Roof Sheathing Water Piping Piers Roofing .Sewer Garage Fdn. Vents Fixtures Footings Stemwa I I Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for physically handica ed Conformance of ex. structure Appliances Gas Pipinq & Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath. Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) S PERMIT NO. 4916-76MHI (e >e l � PERMIT EXPIRES 8/31/77 OWNER ELIZABETH CARR CONTR. S .O . S . MH SER. LOCATION (A.P. 62-45-28 W/S.Big Bend Rd, 3 mi. S of Hwy 70, Oro. Temp. Power Pole Called PG&E Temp. Elea Serv. Called PG&E Temp. Gas Serv. Called PG&E ° JOB FINALED (Date) (Signature) MOBILEHOME INSTALLATION INSPECTION CHECK LIST 1: Is the mobilehome located w' required separation from lot lines and buildings and generaily conform to,. -plot plan? Yes No " 2. Does the mobilehome have required clearances above ground? (Sec.5085) Yes No 3. Are footings and supports properly sized, spaced,, and braced as�Rer approved plans? (Note possible variation at spring shackles.) ( ec. 5082 & 5083) Yes V/ No 4. Is the mobilehome levels Sec. 5088) Yes No. 77%��� .5. I.f more than a sin are crossover connections properly installed? (Sec. 5Q.88) Yes No 6. Water A. Is fl ible connector of adequate size and properly installed (1/2" ID min.)? (Sec, 5566) Yes c B: Tes -Does water piping withstand workingpressure or.50 lbs. air test? Ye No C. Backflow - If coach.is not State of Call -approved, approved, does station have backflow device and pressure -relief valve? Yes No 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at each end? YesL No B. Does it have minimum %" per foot slope and is it a p p properly supported? Yes No C. Are any leaks detected in drainage system after runnin -gallons of water through each -fixture including washing machine standpipe? Yes No D. If coach is not State of.California a®r_--does station have required trap and.vent? Yes No 8. Gas Piping and Gas Vents A. Connector - Is mobilehome connected to the gas supply with an approved 3/4" minimum mobilehome connector not more than 6 -ft. long? Note: All piping is to be at least as large as the mobilehome gas line inlet without reductions other than the mobilehome connector. Ye No �j B. Test OK as per following procedure? Yes /j' No 1. Open all appliance connector valves.? ' 2.. Shut off appliance burner and pilot valves. 3. Air test with manometer to 10"-14" water column, or test xdith slope gauge (minimum 6oz.-maximum 8 oz.) calibrated in tenth pound increments. Test for 10 min. without drop. 4. Connect gas meter to mobilehome with connector, turn on gas, test connections with soapy water. C. Are all appliance vents properly installed? Yes No 9. Electrical A. Is service large enough to provide adequate amperage -to mobilehome (must equal rating of mobi_lehon.e with a minimum of 100 amp) and other facilities on lot, i.e., water.pumps, garage, cabana, etc.? YesP No B. Is there proper clearances around panels? Yeso No C. Is power supply cord or feeder assembly properly fused? Yes No f D. Is continuity test satisfactory as per the following procedure? Yes No 1. De -energize electrical wiring system of the mobilehome at the edestal. 2. Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. 3. Switch all breakers and switches in the mobilehome to the "on" position. 4. Connect one lead of a test.instrument to the mobilehome grounding conductor and apply the other "Lead to each m.obileilorne supply conductor, including neutral. 5. All non-current., carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. 6. Upon completion of the above procedure, the power supply cord or feeder.assembly conductors. shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the mobilehome. Upon satisfactory completion of the electrical tests, the lot or site service equipment may be approved for energizing. 10. I's job card signed by Health Department for water and sanitation? 11. If everything okay, sign off card and tag services. MOBILEHOME DATA Manufacturer and/or Namestyle Length b76( Width Vehicle Serial No. State Identification No. Additional,Informati_on or Comments: N COUNTY OF BUTTE —' DEPARTME-NT OF PUBLIC WORKS • P BUILDING INSPECTION RECORD BUILDING, BUILDING (Cont'd) PLUMBING Setback Firewall Soil Piping Forms Parapets 1st Floor. Main Bldg. Restroom Finish 2nd Floor Footings Windows- 3rd Floor Stemwall Sidina To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents • Fixtures Footings StemwaII Garage Vents Insulation - Watei Htr. Heaters Slab Carport Footings Prov. for physically handicapped Conformance of ex. structure Appliances Gas Piping & Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECTRICAL Masonry Walls Throat Rou h Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh MECHANICAL Grd. Fault Prot. Scratch Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final DATE REMARKS OR CORRECTIONS 7c 600z--7 & (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center grive Orovi Ile, California 95965 Telephone: 534-4541 — 7 APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the above-mentioned , property f r inspection purposes. X r�G/ " ' , Date Signature of Permiiifee or Agent Receipt No. _/�T 3,-Q White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date C Building permit expires Date _5_�11_z�5Vz7 BUILDING OwnerE�� &� 0, SQ. FT. OCC. BUILDING VALUATION Mailing Address Telephone No. Fireplace Contractor Total Valuation Mailing Address Permit Fee Plan Checking Fee &/or Penalty T lep ne N —�d Permit Fee Building Address ` PLUMBING No. @ FEE PERMIT FILING FEE J$3.00 . Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. a �- z -- Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 Fe Sa on Fire Dept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans arcel Declaration Parcel Ma P 60' R/W Improvements P Lawn sprinkler system 2.00 ad/ Parcel Approval Plans Approval Permit Fee $ NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 Main service 100 AMP ORSLESS 5.00 Main service EA. ADD'L too AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home JR Others ❑ Main service 1100EAMP OR LESS 25.00 Main service EA. ADD'L too AMP 1.00 NEW CONST. OR ADDNS. ( DACCLBLDGS LING CCUP. &) 2¢sq ft NEW CONSTR. MULTI -OUTLET NON.RESID. (BRANCH CIRCUITS) 2.50ea 7 / 1 NEW CONSTPOWER APPARATUS NON-RESID.R (SINGLE OUTLET CIR.&J CONTRA TORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California BusirlessJ& Professions Code under the name St Ie 0 Y mss) u/ Ex. Occup(OUTLETS OR FIXTURES) BA@ FIXED APPLNS. OR Ex. Occup. OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 qe� License No. d Classification I �r I Mobile Home Facilities 15.00 Misc. Wiring 6.25 I ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor . Code wich requires every employer to be insured against liability W men's Compensation. I have placed on file with the County of Butte a certificate of iWorkmen's Compensation Insurance. I certify that in the performance of the work for which this El permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE ' authorize representatives of the County of Butte to enter upon the above-mentioned , property f r inspection purposes. X r�G/ " ' , Date Signature of Permiiifee or Agent Receipt No. _/�T 3,-Q White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date C Building permit expires Date _5_�11_z�5Vz7 WoArnanshl'o Skull, Be in Accordonc, with Recognize -i Good Prodi'and Of 0 qljqlii-Y 'prescribed for the Spec;fvdd uses si' n the ;i Unifc.-M Building, Numbing f110,1NIcifionul electrical Code. _&16� . fianicu'l Codes 74ho W&*_ Sef6ack shall be 5 ft. Troni 60 J t'ldlt) properly links and 50 ft. front file roc -, Peirn cenferliho of Ac J iffinq a max]- ' 2 mum oda ft. save overhung but entirely out of cill easemcnfs. CIO A 41 q 7:) 71 46#- > c: Q ITJ Jb♦(Z) (A rn (­-� :r T M 1� C10 This -t 01plan, a;,,4_t ASUSy kept on the - job at all times and it is uj,!.3\,,,fU make any chango5 or alterations on rjjj,;� Wil; written pnriiiisson from' the Depar-in-,ent of Pu Works, of But?o, 13UTTF= COUNTY BUILDING DPARTMCI APPPOVE-D .�. a n 2t out of cill easemcnfs. CIO A 41 q 7:) 71 46#- > c: Q ITJ Jb♦(Z) (A rn (­-� :r T M 1� C10 This -t 01plan, a;,,4_t ASUSy kept on the - job at all times and it is uj,!.3\,,,fU make any chango5 or alterations on rjjj,;� Wil; written pnriiiisson from' the Depar-in-,ent of Pu Works, of But?o, 13UTTF= COUNTY BUILDING DPARTMCI APPPOVE-D �- COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS 7 County Center Drive —' Oroville, California 959657(� Telephone: 534-4541 (`C-�v APPLICATION AND PERMIT W"" y "' ­­— . "­ ups" MV This permit is hereby issued under the applicable provisions of above-mentione rty for inspection purposes. the Butte County Code and/or resolutions to do work indicated q�� ' above for which fees have been paid. to l/� DIRECTOR O PUBLIC WORKS ^�f SZtufPermitee or Agent B Date1� /bReceipt� ga � — White-D.P.W. _ Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant uilding permit expires Date. y- BUILDING Owner SQ. FT. OCC. UILDING VALUATION o Mailing Address Telephone No. Fireplace Contractor Total Valuation Mailing Address (�, Permit Fee Plan Checking Fee &/or Penalty e o. Permit Fee Building Address PLUMBING No. @ FEE PERMIT FILING FEE J$3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 0 Each gas water heater or vent,, ----1.50 _ A. P. No. CQ m.c / J Zoning & Planning Gas piping system 1 - lets 1.50 Each additional et .30 ees .C.S i tion Fire Dept. Fire Zone Use Permit Buildings er 5.00 EQA Parking Plans ParcelParcel Declaration a P 60' R/W ImprovementsLawn sprinkler system 2.00 Bldg. Plans Recd I P4,erApprovol I P a pproval Permit Fee $ $ NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ ELECTRICAL No. @ PERMIT FILING FEE Main service 800v OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD O AMP 2.50 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service °o E P oR LESS 25.00 Main servi EA. ADD'L too AMP 1.00 N.OEW CDNST ( AACCLBLDGDWELINGS.OCCUP. &) 20sgft NEW CONSTR. MULTI -OUTLET NON -R ESI D. (BRANCH CIRCUITS) 2.50ea NEW CONSTR. (POWER APPARATUS &) NON.RESI D. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style f. L ^ Ex. Occup(OUTLETS OR FIXTURES)@L� BAL@1 FIXED APP LNS. OR Ex. Occup.(OUTLETS (RESID.) EA) 2.00 Temporary service 00 Mobile Home Facilitie 15.00 License No. ® Classification Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permi Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Wor en's Compensation. have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby .. MECHANICAL No.1 @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilatio Hood 2.00 Permit Fee $ $ TOTAL PERMIT FEE $ W"" y "' ­­— . "­ ups" MV This permit is hereby issued under the applicable provisions of above-mentione rty for inspection purposes. the Butte County Code and/or resolutions to do work indicated q�� ' above for which fees have been paid. to l/� DIRECTOR O PUBLIC WORKS ^�f SZtufPermitee or Agent B Date1� /bReceipt� ga � — White-D.P.W. _ Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant uilding permit expires Date. y- t 1N3W1Udd71CI- JNicnina uNno 3.uns I N\ ...0. ^, '�J,nf� ut • `J j! �, C }G t`llIUJIXPI.[! e 3UItt!WJ�7Ci 'E>C`M �`C}1 }O .11} Ia(u.77 £Iral�i J1U�} '11 Of p. -,Q A;;jcjc.jd -r1i til t KIM 'n4110 }A A{ut:nz) 'sj,o 0119nd 10 4u,%tJ:J,o: a(3 o.•t :.u:: i ..� ..tai J u;►�},� .:, 01 III)MOlUel '.� t� u i Cw.a� 4V '• l;�• 09 ISM suol};»;�:�.,�s },rr'O su,,Idfo {±s $,yl"I > E 0,5 -p z i0 0 v 'v m 3 o � m sc° DZ CD'A O :� Q A Q0 o m -«;3QQca i Q . > — — — m 0 A' C aT ID � ST too fio C -D• < �CD CD 4,n �x- Q ° 7 0 7 A CL �n Q '-0-0 O Q.� A N �• N co 3 =(D a. Q_ S' I e760 � ' m 3 c tT 0 — m 3 N m c T c •� 0 a o a .a m 3 „ r n 3 as C I � ' m 3 c tT 0 — I , BnirDiw D;,tbV9lV4EVU BnllEOf1b1bA j wclxlwnl,l ,t 5 {�' �.. w OAGLP LO ?0 it' {lou AW I • I, y f j•`O1F2' COflu}%1 Ot Qflji(V sw 1•.o pc :cliwFu} of b"�'Icc Cil f,u'Gq\tfl' 40 1p!: t:+ o{ by ije Gill xt,.c.t;cc.}!oul Wf121 Po / S 20- Po. 4 ^2' P r F i X ✓, y asua �y p'p r Z 0 r X 9 0 N x 00 V cg D _ o ,00", aaP,pr .e V dtl 0 P _ Xd6'w�110 0 " \ u.° qo p 0 fl fi, 9 '0 X �. G p4 'OJ fro 0-rJ .P ��9 ;. 7 0' 0- Gr-, 0 = o'.. W Np q C, t6 0 0 SSS 3 �, nP n u aL. a �4 ✓.0 S .�Jrr� epcc �0n �LP Ys'? o7da� \\ �➢o qp oFY p � ° •� W m i J �f/�� ° 061' :°:7y ` I'• ' a 1� J, oq y o " -f L �� W P of p ,CJI o P a P' G O G� -r 9 �10"�•I L_ w 'v Ifl s 0, D- / r o " r a' 9u0d 4.00" r--=�- o? o -I r f4° 0 / S 20- Po. 4 ^2' P r F i X ✓, y asua �y p'p r Z 0 r X 9 0 N x 00 V cg D _ o ,00", aaP,pr .e V dtl 0 P _ Xd6'w�110 0 " \ u.° qo p 0 fl fi, 9 '0 X �. G p4 'OJ fro 0-rJ .P ��9 ;. 7 0' 0- Gr-, 0 = o'.. W Np q C, t6 0 0 SSS 3 �, nP n u aL. a �4 ✓.0 S .�Jrr� epcc �0n �LP Ys'? o7da� \\ �➢o qp oFY p � ° •� W m i J �f/�� ° 061' :°:7y ` I'• ' a 1� J, oq y o " -f L �� W P of p ,CJI o P a P' G O G� -r 9 �10"�•I L_ w 'v Ifl s 0, V' p n Xp9 / P D 0.o b =Llo Il' f�c a N p P t 4.00" r--=�- o? o m 0 f4° 0 o. it°'• s c Lo SInn 0 ''• �� � p p �� p N 0� P }•i4, Efl x 0 P P )Cp S'F J P n iprD.J 7 4 3� v0 J i� p P 0' 0 is 06P 'p O(dL' G �•/� i P 0 l( Lfy f .o r P hP r ry P Q; o 9 D 11 i. P .• N P p J' ^ P LL '6 p P 9 W �10"�•I L_ w 'v Ifl s 0, V' p n Xp9 / y�so O Il' f�c a N p P t N Nf W0 m 0 f4° 0 o. it°'• s c Y 9 SInn 0 ''• �� � p p �� p N 0� P }•i4, ^.rJ'r. x 0 P P )Cp S'F J P n iprD.J 7 4 3� v0 J i� p P 0' 0 is G .r / G �•/� i P 0 l( Lfy f .o r P hP r ry P Q; o 9 D 11 i. P .• N P p J' ^ P LL '6 p P �p J 1 C�A'F tn 1 01' � .✓i P �9 X' 0 P 0 n v, n % C °i q r # P r tP N C. ,r r�i p I r 1 i II a `I � F- � I pg� � rD o is ggs qo�9 3 P 1 t -' J 'SmrS fap o r•' ^ Vfl �P X IS i F �i rLS 5; p4, P a"p o p3D, n p + r 0 A 'P -11 , G 7O�� �10"�•I L_ w 'v Ifl s 0, V' p n Xp9 0, y�so Il' f�c N p P t Nf W0 1.95" Gp mho .0 �10"�•I L_ w 'v Ifl s 0, F.. gym. O 0, ° t O W vW O Nf W0 m 0 f4° o ➢ ,r G p3 9• o. it°'• s c 2.00" r a 0 '0 0, � P? P 1.9 L O.D D � L 0 ''• �� � p p �� p N 0� P }•i4, ^.rJ'r. x 0 P P )Cp S'F J P n iprD.J 7 4 3� v0 J i� p P 0' 0 is G .r P 0 P n P / G Y�• �� n' P Q; o 9 D 11 i. P .• N P p J' ^ a'I/..�i 0 7y '6 p �p ^ rn P 9 P + 3 P £• 1 01' � .✓i P �9 X' jJ n .� 9 i� 7• �_ J r0 3 9 1 I' U' 0 J, p P, ) P U i ,J �_ 9 P 0 OPS -rj�� 90� 0 J' PJ 03 rP 3�9a AK.O �3L �u C�£. O.p x P 9 r H Q i •^ P P (. D P a 1 P O a OryP n j P• G i s 9 0% .p. r i "O S y-0 L 9 P F 9 j+ xtfN c •J ; a P 9 p ^ ./` P j fl L r P O r P ' s N (• r ' ID D a n£ � .r � ° +g p p ➢ q J r ,moo r• u '.. 2 p� �.rr p �Pv � r v �� Lo 7 /..�.. Y _ COUNTY OF BUTTE — DEfi�ARTENT OF PUBLIC WORKS 7 County Center Drive = UrovWle, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT X9/6 u . — — —FI -11 Lau— vi mu Vvullty v1 ouLLu tv viper uNvn trle above -m tinned property for inspection purposes. X Date NOV e mi a or Agent Receipt . 46 ge 1 7 6 -7 White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY • Date permit expires Date B/3,_7/�7 BUILDING Owner ELS ZA 3€7-/4 G14Iq /2 SQ. FT. OCC. BUILDING VALUATION Mailing Address Telephone No. Fireplace Contractor Total Valuation Mailing Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. e '.7'- 7,el/ Permit Fee $ Building Address Lk//L' 123c/\� .116 PLUMBING No. @ FEE PERMIT FILING FEE $3.00 //64/ 7o Each Trap 1.50 Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 p A. P. No. Zoning & Planning Gas piping system 1 - 5 outlets 1.50 Each additional outlet .30 F 4< WA3, .9aR4t284ew FireDept. Fire Zone Use Permit Building sewer 5.00 EQA Parking Plans J Parcel Declaration Parcel Ma p 60' R/W Im r p ovem is Lawn sprinkler system 2.00 Bldg. Plans Recd Parcel roval Plan pprovol Permit Fee $ $ NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER ELECTRICAL No.1 @ FEE PERMIT FILING FEE $3.00 it/S �lLy ?/ON Main service 100 AMP OR00V OR LE LESS5.00 Main service EA. ADD'L 100 AMP 2.50 Main service Ov ER 00 AMP OR LESS 25.00 Single Family ❑ Duplex ❑ Mobil Home Others ❑ Main service EA. ADD'L 100 AMP 1.00 ' NEW CONS. OR ADDNST ( ACCLBLDGDWELING OCCUP. &) 20sgft NEW CONSTR. MULTI.OUTLET NON.RESID. (BRANCH CIRCUITS) 2.50ea .NEW CONSTR. POWER APPARATUS &) NON.RESID. (SINGLE OUTLET CIR. CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the namg style of- ` �. F t 4 a dv Ex. Occup(OUTLETS OR FIXTURES) BAL@1 Ex. Occup ( FIXED TS (RESAPPLN• OR OUTLETS (R ESi D.) EA) 2•00 Temporary service 10.00 Mobile Home Facilities 15.00 License No.-(�?�Q� Classification Misc. Wiring 6.25 I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. sI certify that in the performance of the work for which this permit�is issued I shall not employ any person in any manner Ss to become subject to the Workmen's Compensation Laws of California. MECHANICAL No.1 @ FEEPERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 1 1 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above I information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby 6171V 14---7r,4,d—A-47101V 30,V TOTALPERMIT FEE a O $ 1 u . — — —FI -11 Lau— vi mu Vvullty v1 ouLLu tv viper uNvn trle above -m tinned property for inspection purposes. X Date NOV e mi a or Agent Receipt . 46 ge 1 7 6 -7 White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY • Date permit expires Date B/3,_7/�7 i This set of plans and specificati s kept on fhe j�.9,, at all ti es and it i MUST be ma,�Ce any chnrC;cs or alterations ons me without written permission from the Departm of of Public Works, County of Butte. The Setback shall be #t. from the ide property .line and 5 ft. from the nterline of the road, oermiffing q ma 'mum of a 2 ft. eave overhang. O RME C UNtY pE RrM APPRO_ ! Nr X OY Hd S°S Q � o bo � N t NINa i This set of plans and specificati s kept on fhe j�.9,, at all ti es and it i MUST be ma,�Ce any chnrC;cs or alterations ons me without written permission from the Departm of of Public Works, County of Butte. The Setback shall be #t. from the ide property .line and 5 ft. from the nterline of the road, oermiffing q ma 'mum of a 2 ft. eave overhang. O RME C UNtY pE RrM APPRO_ ! Nr X OY Hd S°S � 1 BUTTE COUNTY DEPARTMENT OF PUBLIC .WORKS 7 County Center Drive, Oroville,^CA. PHONE: 534-4541' 1. Owner's name: 2. Installer's na ' MOBILEHOME INSTALLATION SHEET 3. Is the site currently under permit? Yes / / No / / ( If yes, furnish permit number s ) OR Is the site an existing site? Yes No ti (If yes, furnish two'(2) plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach.fields and clear of all setbacks and easements?, Yes /t No ( If no, clarify 5. What is the mobilehome electrical rating? ---------- ----------- c MOO Amp 6. What is the mobilehome site service rating? --------- �--------rwe 'Amps 7. What is the mobilehome site circuit,breaker rating? ----'- --------- ps 8. Is there any other electric load to be served by the mobilehome /k. site service? --------------------------------------------------- Yes / / No / / (If yes, identify the load and size: W ( (Load) 'Z-0 (Amps) 9.' What is the mobilehome site gas'pipe'size?---------------------- 3 (in.) 10. What is the type of gas service? ----------------------------- Natural / / LPG 11. What is the gas pipe length from 1 meter or tank to the mobilehome? 12. What, is/the mobilehome gas demand? ------------------------------ .(BTU) 1,!`'JAT$(This;information not required if pipe length less than 6 ft. on natural gas or less `thatn450(.`ft. on LPG.) C ..moi ` T, r� -ii • 6l L c All MOBILEHOME SUPPORT DATA Mob ilehome Mfr. rl-�L1 P �j9 (^ Setup Model No.k- SSS Year [ (a Width 1 (ft.) Length h ""/ ' (ft.) Expando' Size ft.x /Aft. (Draw support—details below) . On all mobilehomes manufactured after October'7, 1973, furnish manufacturer's installation manual and structural setup sheets (if not.on .file with.the County of Butte). A - Sinkle = Footings- (check. one) *If center piers are other than drawn above, draw in locations, spacing, and dimensions. . 1. Wood. either pressure treated or fdn. grade. �`) 2. Concrete pad. 3. Other,: specify Supports (check one) 1. Concrete block / / 2. Concrete piers 7 3. Steel piers 4. Other, specify Typical Support Footing Size Max. Pier Spacing Max. Overhang BUTTE COUNTY BUILDING DEPARTMENT APPROVED y�Y BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS SPECIAL-'INS'PECTION REPORT Owner: ,�S1-/7-,4i E. Other 1. Maintenance and repair: 2 F'h ire azards: 3. Safety hazards: 4. Weather protection:_ 5. Underfloor and attic 6. Comments: ventilation: F. Commercial Buildings 1. Roof covering: 2. Distance to property lines: 3. Physically handicapped: 4. Restroom floors and walls: 5. Exits: 6. Improvements: 7. Zoning: 8. Comments: G. Field Problems or Violations 1. Problem or violation (give complete description): 2. What action taken (give complete description): 3. What action recommended: 77 A. Information only - file. B. Hold for ten (10) days, then write letter. C. Write letter. 7 D. Other.• ��i PERMIT NUMBER - B 4867-74 P E PERMIT EXPIRES OWNER Columbus Carr CONTR:. LOCATION (A.P. W/S Big Bend Rd., 3 mi. so - of Hlway 70., Oro. COUNTY OF BUTTE`,` DEPARTMENT OF PUBLIC WORKS— . . 695 Oleander Avenue, Chico — Phone 343-4211, Ext. 70 7 County Center Drive, Oroville — Phdne 534-454?.0 Skyway and Elliott Road, Paradise — Phone 877-3435 air. --71 CORRECTION NOTICE BUILDING OR PROPERTY ADDRESS A routine inspection indicates that the folrowing violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. liJ Inspector Date ,9 G/ 5 - Job A( Owner BLDG. Form Frame Lath Fireplace Final County of Butte DEPARTMENT OF PUBLIC WORKS REQUEST FOR INSPECTION��—%� Z Time Red rmit# s Contractor LUMBING 6 ELECTRICAL OTHER Roug Gas Piping Appliances Sewer M�.Se,-i Water Pipe Te Final Readq for Insp. on 5— ( 1976 Date Inspection� made: DATE REMARKS OR CORRECTIONS a COUNTY OF BUTTE -Department of Public Works ' BUILDING INSPECTION RECORD Zoning Setback Forms Foundation Piers & Girders Fireplace Rgh. Plumbing Bond Beam Lath & Plaster_ Rein. Steeh. Gas Piping & Test Found. Vents Framing '•. Plmg. Topout Rough Elec. Wtr. Htr. Furnace Kitchen Vent Firewall Garage Vents Sanitation & Water ELECTRIC GAS BUILDING Temporary Temporary Cert. of Occup. Final Final Final DATE REMARKS OR CORRECTIONS a c A COUNTY OF BUTTE — DEPARTMENT OF PUBLI /" 7 County Center Drive - .Oroville, California 95965 ���/// Tel e*ne: 04-4541 APPLIC00 %AND PERMIT auurun; re reseniotives of the County of Butte to enter upon the above-rnnedproerty fo in ction purposes. Date Sig t re of Permitee or Agent /G Receipt . � L)&73-:)__ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR PUBLIC WORKS Date Building permit expires Date .....................�' _ �� BUILDING Owner SQ. FT. OCC. BUILDING VALUATION Mai I i ng Address a _ &49 /�PA/VNI Lo Telephone No. J& a 6 Fireplace Contractor W Total Valuation Mai I Ing Address Permit Fee Plan Checking Fee &/or Penalty Telephone No. Permit Fee $ $ Building Address WI -5 '816 $EwZ!>?nIPLUMBING No.1 @ FEE PERMIT FILING FEE $2.00 x.00 p ./w Each Trap 1.50 © �� Repair drainage or vent piping 1.50 Water piping 1.50 Each gas water heater or vent 1.50 A. P. No. �— �Pj `��7 T Loni ` Gas piping system 1 - 5 outlets 1.50 ,� Q Each additional outlet 30 F ion Fire Dept. Fire Zone Use Permit EQA Parking Parcel parcel Ma 60' R/W Im rov ments Plans Declaration cel P Building sewer 5.00 5,00 Lawn sprinkler system 2.00 . Pl15s-(iec' �yP Pard®/�p}+avaf PI s Approval Permit Fee $ 0.W Q = NEW ❑ ADDITION ❑ UTILITI S OTHER ❑ ELECTRICAL No. @ FEE PERMIT FILING FEE 1 $3.00 3, O -D Main service incl. 1 meter Additional meters, each 1.00 Sub -panel (12 or less) (more than 12) Single Family ❑ Duplex ❑ Mobil Home Others ❑ Range, Cook -top or Oven 1.00 Water Heater or Space Heater 1.00 Light fixtures 20 Bio Receps., switches & fix outlets CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: Hood, Ex. Fan or F.A. Furn. Motor 1.00 Evap. cooler, gar. disp.or D.W. 1.00 Air conditioner or heat pump Water pump To Mobil Home Facilities 5.00 j 0 p Temp. Power Pole 5.00 License No. Classification Misc. wiring I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑ I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this prmit is issued I shall not employ any person in any manner o as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby TOTAL PERMIT FEE $ `)� auurun; re reseniotives of the County of Butte to enter upon the above-rnnedproerty fo in ction purposes. Date Sig t re of Permitee or Agent /G Receipt . � L)&73-:)__ White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR PUBLIC WORKS Date Building permit expires Date .....................�' _ �� ri y r 1 r r� oo, - 'Poo* �g f ! Vit, • Columbus & Elizabeth Carr 1426 6th. Ave. San Francisco., CA. 94122 COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville, California 95965 PHONE: 916-53445 1 t DATE o With reference to the above subject: Attached is:' Application for.permit Building Plans Engr. Calcs. OTHER AM We need the following information: j RE: MOBILE HOME UTILITY APPLN. #4867-74 Typical Plan Sheet Mobile Home Sheet List of Codes Enforced - Permit application signed and completed where indicated with. all copies returned. F e e s o f $ ,Z Z ✓�= .5 :�.e;-.��ci�' °� ,� - �i�d �,�✓ CertificatWorkmen's Compensation Insurance. Contractors License Law information. Letter authorizing signature of Complete plans, in duplicate, including plot & floor plans and complete structural details. Plot plans in duplicate. Structural details in duplicate. Complete plans, in duplicate, prepared`by registered civil engineer or.architect. Engr. calcs. Two (2) sets.of plans in accordance.with changes marked in red.. Sanitation approval from Butte County Health Dept. 695 Oleander Ave., Chico. Oroville. Skyway & Elliott Rd.,Paradi Planning approval, i.e., use permit, variance, rezoning, etc., from Butte County Planning -Dept., 7 County -Center Dr., Oroville. Improvement Plans. Parcel declaration recording data. Verification of access.or right of way by -deed. , Verification of legally created parcel by deed. Deed for:right of way. Parcel map recorded, i As soon as we receive the above.data, we will process your application, or, should you have any questions concerning the above, please contact this office. . JFG:dd Yours very truly, Clay Castleberry Director of Public Works J.F. Glander Assistant Director' 9 All utility, connections shall. be _.a . . located within 4 ft. outside the -rear J f' third sect�pM ' of the mobile home DUT`fE COUNTY n the left `road) side of the mobile ome: • - BUILDING':DEPARTMENT; :�h .... _ , APPROVED J - This si# ofpl¢ns M1 !ST he kes-fin-4 it is unl^wfut� : ♦ . . make angchn_ ". -c ltc,rr" ons on same;' ithout Written rmiss.ion from the`Dep rtment of Public ,t�4 i I ALt Works, bounty of Butte.^ ��� •• -, -ry �. "_` ^ ` -71 ` Y.i '.� v�� � �-.r:�.e.• .'�`�• Y�,.iL .+� k^�.a '`.l � r i _ .... r ,t - I� do Ake r;_ • 'stub -out; to be as er Buttgi�=Caur t, ,Health. Dept. Re r, • j� _ • J ; • ',_ _ �- � �j� -'; , //'`:rte � .;�_ .. _:� ��. • � z�,� •giirer.�enfis.:� � � �� ' t J4 �'•,. .• �/ , "' ` ' `'t ..... ^ 4 � � \_ �. ty: lit' � 5 � C � 4.i r _. s + i :�'E ul? VI _ r� r, p� �,. � Y �► ; -ter �� j fihe�i ba' ` sha11A be 5 ft: fro%r► fl , , , r _ _ = r. r • r side. and the p ;Perty'line , SQ ft. from -/- -�- .- --�` ' : the, cenfier ne ;af the road, permitting Of a 2 .ft. ; eave overhang• , t ,• r .kms } } i '$}�.,! •v _ r� ' Zr4 — i * 'h •rte ra: r _ ,�S.:.c„�4"fi.'..,-. 4 ;��.• c _ ,� "'-'£ 'n`.ir- :.._3 _ _ M�'1S .fit , a- ,..,,.-_•.r . -t /`//���' 1 �s V ba r V� 4 k, It ,.•A'.'�` vy� i G xozaadBUI 2uTp;T09 •$trjsTA odris sat3e►s •Q•Z "soM aTtgrM ;o so3*osT(j Sxaagat3svO Av=a 11 AInxz Asan 9snox xo3oadoui $uTPTTnq `g3TaX qo8 saa pp: Gal *on zoa:juoa.esaetd 'eAoge 943 2ujp4v2os suoTzsonb Aue eAsq noel p1nogg • ..... . •attTAoxp �aATx� se3ua� e�zuno� L 12uam "doa gztFag Aumo ezzn8 oq3 mos; goop eq3 ;o wn3eaot eqz to; tenoaddv uT"go zona► no4 I9:11=ed S"neeT an oz soTxd . •41o301pou n 9:1; sad pesTnbas oqz xo; Atddv pue ozeaTtdnp.uT )loop eq3 ;o euetd texnzonxis puv zot4.3Tmgne nob zegz gse.3snm OA °oxo;asauz I.njox o1gz xo; paxTnbes an vzTmxad 2vg3 ppeTnpe eq eoeeta ezT=vd Axesseoau-ogz.:znogTTA p®og puag STg uo.Ausdoxd xnOA ao xauoTzTpuoa xTtt ae potly:390; pug . sloop pooet a pazaYuTeuoa oney n0A zog3 say;;o e7g3 pamxoM seq xo3zedouT ptsT; sno 30fgns eAoge sgz.oz.soaese;as,gzTM . 9Z•S'-Z9 dV alviod BaTPIT"a .gm L461 `5 Axtmuvr .. :4290...214 xsea lli+l6 . •VO' `oaeTauesd ince *oAV.gz9 - 9Zbi sago sngmntoo ,�'" `"[� ,,.•-' fes'' Y d yr+•;! �• n Owner: Address: Tenant: BUTTE'COUNTY DEPARTMENT OF PUBLIC WORKS SPECIAL INSPECTION REPORTt- cc_ A.P. Date of Inspection) 7f Inspecto;_C� Building Location: Type of Inspection requested: / / 1. Housing / / 4. Other Present .use of A. Sanitation (Housing) 1. Water closet:_ 2. Lavatory: 3. Bathtub or shower: 4. Kitchen sink: 5. Hot and cold water to fixtures: 6. Heating facilities: 7. Natural light and ventilation: 8. Room and space requirements: 9. Bedroom window or door for second exit: 10. Infestation of insects, vermin, or rodents: 11. Connection to sewage disposal: 12. Connection to water supply: 13. Rubbish and garbage facilities: 14. Comments: B. Structural 1. Piers and footings: 2. Floor construction: 3. Wall construction: 4. Ceiling and roof construction: 5. Fireplaces: 6. Comments: . C. . Electrical 1. Service and ground: 2. Receptacles: 3. Fusing: 4. Comments: D. Plumbing 1. Fixtures connected and vented: 2. Gas water heater: 3. Gas heating vents:" 4. Comments• (continued on back) E. Other 1. Maintenance and repair: 2. Fire hazards: 3. Safety hazards: 4. Weather protection: 5. Underfloor and attic ventilation: 6. Comments F. Commercial Buildings 1. Roof covering: 2. Distance to property lines: 3. Physically handicapped: 4. Restroom floors and walls: 5. Exits: 6. Improvements: 7. Zoning: 8. Comments G. Field Problems or Violations 1. Prob em or latio (g iv complete escriptioza): 7 3. What action recommended: �� t T1 A. Information only - file. B Hold for ten (10) days, then write letter. C. Write letter. D. Other: ft ®iAFvRIAGE Lim Sv'^P0-ms AS SPECIFIED BY HOME MANUFACTURER 3 -.STANDARD tR-.ICAL SUPPORT PIERS AS' • 4 INCH SHORT -TUBE < ' ®iAFvRIAGE Lim Sv'^P0-ms AS SPECIFIED BY HOME MANUFACTURER xzz -.STANDARD tR-.ICAL SUPPORT PIERS AS' • 4 INCH SHORT -TUBE < ' 8 INCH LONG TUBE4 SPECIFIED BY HOME MANUFACTURER - 3/8' BOLTS 14 INCH EX -LONG TUBEzo ' LL T I r i� MUST EXTcl:- ¢ Wc S TUBE cls FT -LBS) TORQUE ' 3' MIN IN TO CLAMP go I. ELECTRODES: E70 U. PLATES: A STM Ul BOLTS: STAND ASTM A301 SEISMIC 1�PLATE BASE ASE • �ODRDID xmD.c rt -MTM mul TYPICAL BEAM 4' THREADED ROD T SHALL 11.5 MCH REGULAR 2 �wa w L_TJ 1 �JEl1= wa w jv� 1 U 10.3 INCH EXTRA LARGE H 9 P OF 4 M O 9. THIS FOUNDATIOpp SYSTEY PLAN I3 DESIGNED TO BE CONSTRUCTED ON A FAIRLY LEVE, SITE WITH NO FJISIING SOri PROBLEMS, IF SLTTTIEMENT OCCURS DUB TO POOR 3011, /8'. X t l/4' BOLI N i' SES NOTE 11. 10. CHASSIS BEAM SUPPORTS SHALL B LOCATED AND SIZED FOR LOAD AS SHOWN IN THE MOBILE HOME INSTALLATION INSTRUCTIONS. V W ITH HARDENED WASHER .THE It. IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.�.) CAN OCCUR. MANUFACTURED HOMES SHALL BE READJUST WHEN D.S. EXCEEDS 1/4 , OR WHEN IT WLLL ADVERSELY AFFECT I I ""'PLATE I I I I Not to Scale IJP 3. MAXUM LENGTH OF TRIPLE IM SPACING OP STANDARD PIERS AND PAD SUPPORT'S TO HB DETERMINED By ICSJ 11i I ILSI 1 STATE MOBLE HOMES PARK ACT. c H 13. THIS SYSTEM IS ADAPTABLE 14TH HOLLOW MASONRY BLACK PLER9. A A. 8 FEET FOR SINGLE WIDE COACHES. B. 10 FEET FOR 20 FEET DOUBLE WIDE COACHES FOR 24', 28', 28' Mt 32' DOUBLE WEDES Mt ALL TRIPLE WIDE COACHES W � a 0 C. 12 FEET 5. FOR TRIPLE WIDE COACHES, FOLLOW SAME PLACEMENT PATTERN AS ASHOWN ON THE co ►z LSJ � lJ ' IJ ►+r _ co LI LTJ 8. FOR ANY LAYOUT SHALL BE REVIEWED AND APPROVED BY THARP # ASSOC.. INC. SSW roDATIOe I I PADS I I (sj sIS41OC Pm -,I !POUND?T� I �m (� (� ( OUTUNT OF4 4 D 4 4 D� 4 or M011nn COACH 24', 28'. 28'. OR 32 12'. 14', OR Ie' PLAN PLAN DOUBLE WIDE MOBILE COACH goal.: 1' - 10' I SINGLE WIDE MOBILE COACH scale: 1' - 10' So= PIER An .-r0MDATmm PAD' . COACH 1 BEA" BOLTS 2' DIA STD PIPE MAX HT ABOVE CLAMP xzz FIELD DRILL HOLES • 4 INCH SHORT -TUBE OPTION OF ' 8 INCH LONG TUBE4 COACH C - 3/8' BOLTS 14 INCH EX -LONG TUBEzo I/4'x2'x4• TIG WELTp MUST EXTcl:- ¢ Wc S TUBE cls FT -LBS) TORQUE ' 3' MIN IN TO CLAMP go I. ELECTRODES: E70 U. PLATES: A STM Ul BOLTS: STAND ASTM A301 SEISMIC 1�PLATE BASE ASE O PIER TYPICAL BEAM 4' THREADED ROD T SHALL 11.5 MCH REGULAR 2 U) � u 16' PLATE LEGS L 10.3 INCH EXTRA LARGE H 9 P OF 4 M O 9. THIS FOUNDATIOpp SYSTEY PLAN I3 DESIGNED TO BE CONSTRUCTED ON A FAIRLY LEVE, SITE WITH NO FJISIING SOri PROBLEMS, IF SLTTTIEMENT OCCURS DUB TO POOR 3011, /8'. X t l/4' BOLI N i' SES NOTE 11. 10. CHASSIS BEAM SUPPORTS SHALL B LOCATED AND SIZED FOR LOAD AS SHOWN IN THE MOBILE HOME INSTALLATION INSTRUCTIONS. V W ITH HARDENED WASHER .THE It. IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.�.) CAN OCCUR. MANUFACTURED HOMES SHALL BE READJUST WHEN D.S. EXCEEDS 1/4 , OR WHEN IT WLLL ADVERSELY AFFECT � E IA y ""'PLATE SEISMIC PIER Not to Scale C.P. SEISMIC PIER#1-PATENT #5595366 e - 3/0. x 1' BOLTS xzz FIELD DRILL HOLES AREA. 3. THIS PLAN IS CONSIDERED TO CONSTITUTE A FOUNDATION SYSTEM. OPTION OF 0 u 4 - 914 TEX STS COACH C N OR J BEAM I/4'x2'x4• 3' x 3' PLATE ANGLE 3' VIDE Wc ACCORD c. SHALL BE WELDED ACCORDING TO AWS SPECIFICATIONS: 4 - 1/2' go I. ELECTRODES: E70 U. PLATES: A STM Ul BOLTS: STAND ASTM A301 SEISMIC BOLTS 1� Iv. THREADED ROD: COLD DRAWN LAW CARBON WELDABLE METAL COMPONENTS INCLUDING NAILS R SCREWS ETC. ARE TO BE O PIER TYPICAL BEAM CONNECTION Not to Sccle 1IMNG2 So IN OVERSIZE ID OR CORNERB BREAKAGE . Jb I/C 1 3/e• rLANGELL S NCHOR INSSTEER t I in 1'I 4x4 -4x4 WWF PRECAST FOUNDATION PAD Not to Scole 3D'x31 PI HOLES FOR 1/2' x 2 1/2' CA 18'x24'x3/4" PLYWOOD A H 38' I MAX( ELEVATION NOT TO SCALE 3/4' PLYWOOD SHEETS ­ •^rte 0 WITH rHVS ALTERNATIVE PLYWOOD FOUNDATION PAD Nu G TO SCALE R.EFERENCE:CAIIFORNIA CODE' OF REGULATIUNS,- TLTIE 28 AND U.B.C. 1994 EDIiTON. 1. •OtSIGN LOADS: COACH SIZEAM; C LOAD SINGLE HIDES 30 PsM 1 40 Est 0 M B4 DOUBLE WIDES 30 Pst 40 Psf M B 4 IDLE HIDES 30 Psf 40 Psf M B 4 n� v •.asu i .:.I'- .i 2. THE DESIGN (AADS SHALL BE CONSISTENT WITH ROOF LIVE LOTHINAD, WIND LOAD AND SEISMIC ZONE AS ESTABLISHED FOR PERMANENT BUILDING WIA SPECIFIGI LOCAL xzz x o AREA. 3. THIS PLAN IS CONSIDERED TO CONSTITUTE A FOUNDATION SYSTEM. C ' 0 u 4. ALL FOOTINGS ARE TO BE SUPPORTED BY FILM, UNSATURATED. UNDISTURBED SOIL FOOTINGS ARE DESIGNED FOR 1000 PSF TOTAL LOAD SOLI. PRESSURE W N AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. U) 5. STRUCTURAL STEEL. ASTM pp,yy SHANFABRCORbHLUBEBRIAD TOWSPMEI CAbONS. Z. Wc ACCORD c. SHALL BE WELDED ACCORDING TO AWS SPECIFICATIONS: 1-N O go I. ELECTRODES: E70 U. PLATES: A STM Ul BOLTS: STAND ASTM A301 U i y 1� Iv. THREADED ROD: COLD DRAWN LAW CARBON WELDABLE METAL COMPONENTS INCLUDING NAILS R SCREWS ETC. ARE TO BE O C � d. ALL 8. THE PIER UPIVE TPPORT ASSEMBLIES SHALL BE COATED WITH SHERMAN WU11W E8l-RC2 U) V 1 W OR APPROVED EQUIVALENT- 7. THIN C.P. SEISMIC P �H�(� BE LISTED AULD ZABEIED BY CERTIFIED TESTING AND FOR THE FOLLOWING WADS: U) � u p ++ CONSULTING SERVLCESCTC) e. LATERAL 1700 LBS. ULTIiATE LOAD b. VERTICAL : 13000 ULTIMATE LOAD. H 9 S. THIS FOUNDATION SYSTEM 19 FOR PLACING MANUFACTURED BUILDINGS CONSTRUCTED WITH LONGITUDINAL OR CROSS JOINTS. M O 9. THIS FOUNDATIOpp SYSTEY PLAN I3 DESIGNED TO BE CONSTRUCTED ON A FAIRLY LEVE, SITE WITH NO FJISIING SOri PROBLEMS, IF SLTTTIEMENT OCCURS DUB TO POOR 3011, F4 r ` N i' SES NOTE 11. 10. CHASSIS BEAM SUPPORTS SHALL B LOCATED AND SIZED FOR LOAD AS SHOWN IN THE MOBILE HOME INSTALLATION INSTRUCTIONS. V W oEi E .THE It. IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.�.) CAN OCCUR. MANUFACTURED HOMES SHALL BE READJUST WHEN D.S. EXCEEDS 1/4 , OR WHEN IT WLLL ADVERSELY AFFECT � E IA y THE USE OF THE MANUFACTURED HOME. 12. STANDARD PIER & FOOTING SPACING PER MOBILE COACH MANUFACTURER'S O F�1 n INSTALLATION MANUAL WITHOUT MANUFACTURER'S INSTALLATION MANUAL IJP 3. MAXUM LENGTH OF TRIPLE IM SPACING OP STANDARD PIERS AND PAD SUPPORT'S TO HB DETERMINED By rWrhh V d STATE MOBLE HOMES PARK ACT. 4. UNLESS APPROVED BY THARP [s ASSOC.. FLOOR TO RIDGE HEIGHT NOT TO EXCEED: 4. H 13. THIS SYSTEM IS ADAPTABLE 14TH HOLLOW MASONRY BLACK PLER9. A A. 8 FEET FOR SINGLE WIDE COACHES. B. 10 FEET FOR 20 FEET DOUBLE WIDE COACHES FOR 24', 28', 28' Mt 32' DOUBLE WEDES Mt ALL TRIPLE WIDE COACHES W � a 0 O 01 In C4 1 fU kD %D v FOCNDATION PAD NOTES* FOUNDATION 1. THE'FOUNDATION PAD SHOWN 04 THIS PIAN 19 A PRECAST CONCRETE FOUNDATION -PAD. xzz 1-1 44 LO I THE PLYWOOD F°)UNDATIOP PAL' ';AY BE !'SED AS AN _-LIMRNATE. 2. FOUNDATION PADS SHALL BE PLACED ON LEVEL UNDISTURBED SOIL 3. CONLMETE FOUNDATION PAD A. 3000 PSI AT 28 DAYS AS TESTED AND MANUF. BY STARLITE WEIGHT CONCRETE. v B. PREFERRED PAD ORIENTATION WHERE EVER POSSIBLE IS THAT THE LONG DIMENSION OF THE PAD BE PERPENDICULAR TO THE COACH BEAM (AS SHOWN ON THE PLAN). H ALF OF THEN IQ C. WHERE FIELD PADS IN A TRAVERSE OLDNE CAN BE ROTATNS REQUIRE PAD E DIMENSION D THAT THE LONo MORE NG D W 44 OF THE PADS ARE PARALLEL. TO THE COACH BEAM. DATE- II -07-02 4. PRESSURE TTZCATED FOUNDATION PAD A. 3/4 INCH A.P.A. 48/24 EXTERIOR P.S.I.-83 CC. PLUGGED, NER-QA397,PRP-108. SCALE, AS SHOWN V) >_ DRAWN, YMW COACH SIZE NOTES: 1. MAXIMUM LENGTH OF SINGLE WIDE COACH - 88 FEET.z U Z O O 2. MAXIMUM LENGTH OF DOUBLE WIDE COACH 70 FEET. WIDE COACH 70 FEET. SHEET: co E- 3. MAXUM LENGTH OF TRIPLE IM 0o W d 4. UNLESS APPROVED BY THARP [s ASSOC.. FLOOR TO RIDGE HEIGHT NOT TO EXCEED: 4. V a Z A A. 8 FEET FOR SINGLE WIDE COACHES. B. 10 FEET FOR 20 FEET DOUBLE WIDE COACHES FOR 24', 28', 28' Mt 32' DOUBLE WEDES Mt ALL TRIPLE WIDE COACHES W � a 0 C. 12 FEET 5. FOR TRIPLE WIDE COACHES, FOLLOW SAME PLACEMENT PATTERN AS ASHOWN ON THE co ►z DOUBLE WIDE NOBLE COACH PIAN. COACH SIZE OTHER THAN AS SHOWN ON THIS PLAN OR REFERENCED ABOVE. ►+r _ co 0 8. FOR ANY LAYOUT SHALL BE REVIEWED AND APPROVED BY THARP # ASSOC.. INC. Qi (sj HOBQJ?HOW POUND, ON S (Tm MWH AND SAFETY CODE. SBCTANI im APPROVED IRwwr TO CORA:.CTIONS NORBD ANaaNiLODO MOP AUIf10KI7� D%AIIa6�BAef miomanDBvwxr/ I%DY� AMLWAMAVWB uM AND REMLATIONS Hale d6ifuah <; I oD by N®1N3 ffiMa�A� 4 xzz rTi W a0 P 44 IQ O 44 DATE- II -07-02 OQpoFES3 SCALE, AS SHOWN N, es m DRAWN, YMW JOB #: 95-36-80 F CIVIL r �OFCAL SHEET: AS SPECIFIED BY VHOME 1 -STANDARD VERTICAL MANUFACTURER SUPPORT PIERS SPECII+'fED BY HOME MANUFACTURER M=t or a COACH n n n n B INCH LONG TUBE 4 - 3/8' BOLTS 14 INCH EX -TONG TUBE `P TURK MIST EXTc)7- f a ni�n v n n n h 4 � - y AS SPECIFIED BY VHOME 1 -STANDARD VERTICAL MANUFACTURER SUPPORT PIERS SPECII+'fED BY HOME MANUFACTURER M=t or a COACH n n n n B INCH LONG TUBE 4 - 3/8' BOLTS 14 INCH EX -TONG TUBE `P TURK MIST EXTc)7- 180 FN ¢ O (15 FT -LBS) TORQUE a ni�n v n n n h 4 � 4. ALL FOOTINGS ARE TO BE SUPPORTED' BY FIRM, UNSATURATED. UNDISTURBED DESIGNED FOR 1000 PSF TOTAL LOAD SOIL PRESSURE W +N n h n n u upu se1s1IC P= ! rotTIIDA7� u o v o a PIER#1-PATENT #5595366 C b. SHALL BE FABRICATED ACCORD I7C 70 Alsc sPEC1FlCAT1o17s. f, OITL 4 4 OF MOBILE COACH DOUBLE WIDE MOBILE COACH swe: I' - 10' , COACH I BEA" r X r aaO�T'i9 ...tErr'mm. 4 EDITION. NO'CES: ' REFERENCE:CALRNLA CODE- OP REGULATIONS. TITh 28 AND U.B.C. 189 sI'O 2' DIA 1, , SIGN (AADS: . MAX HT ABOVE CLAMP Til W B INCH LONG TUBE 4 - 3/8' BOLTS 14 INCH EX -TONG TUBE `P TURK MIST EXTc)7- 180 FN ¢ O (15 FT -LBS) TORQUE I � 4 - 1/2' CLIAWPLATE 3. THIS PLAN IS CONSIDERED TO CONSTITUTE A FOUNDATION SYSTEM. 4 � 4. ALL FOOTINGS ARE TO BE SUPPORTED' BY FIRM, UNSATURATED. UNDISTURBED DESIGNED FOR 1000 PSF TOTAL LOAD SOIL PRESSURE W +N SOIL FOOTINGS ARE AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. rn LiJ lit se1s1IC P= ! rotTIIDA7� II. STRUCTURAL STEEL: • e. SHALL CONFORM TO ASTM A36 pp•�� 3p r ME=Cl V[ • N C.P. SEISMIC PIER#1-PATENT #5595366 C b. SHALL BE FABRICATED ACCORD I7C 70 Alsc sPEC1FlCAT1o17s. f, OITL 4 4 OF MOBILE COACH COACH I BEA" r X r aaO�T'i9 ...tErr'mm. 4 EDITION. NO'CES: ' REFERENCE:CALRNLA CODE- OP REGULATIONS. TITh 28 AND U.B.C. 189 sI'O 2' DIA 1, , SIGN (AADS: . MAX HT ABOVE CLAMP STD PIPE 4 INCH SHORT TUBE B INCH LONG TUBE 4 - 3/8' BOLTS 14 INCH EX -TONG TUBE TIGHTEN TD -LRS TURK MIST EXTc)7- 180 FN ¢ O (15 FT -LBS) TORQUE 3' MIN IN TO CLAMP 4 - 1/2' CLIAWPLATE COACH SIZE SINGLE WIDES 30 Ps! 40 Psf 0 M B 4 DOUBLE WEDES 30 Pst 40 Pst Y B 4 LE RIDES 30 Pst 40 Pet M B 4 p)LIn O L 0 ` OD H� Z.z Iu 0 RICH SMALL 7 IN BASE HE1t*+TX3/16'PLATE 4' THREADED ROD PLATE LEGS 2. TELE DESIGN LOADS SILAId BE CONSISTENT W1TH BOOP LIVE IAAD, WIND (AAD AND SEISMIC ZONE AS ESTABLISHED FOR PERMANENT BUIDING WMHN,A SPECff1Ct LOCAL OPTION OF ILS REGULAR16' 18.3 INCH EXTRA LARGE OR J BEAN �� 3' x 3' PLATE 41 4 - 1/2' /8'.X 1 1/4' BOLT HARDENED WASHER 3. THIS PLAN IS CONSIDERED TO CONSTITUTE A FOUNDATION SYSTEM. uITH CD 4. ALL FOOTINGS ARE TO BE SUPPORTED' BY FIRM, UNSATURATED. UNDISTURBED DESIGNED FOR 1000 PSF TOTAL LOAD SOIL PRESSURE W +N SOIL FOOTINGS ARE AND SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. rn t o SEISMIC PIER Not to Sca(e II. STRUCTURAL STEEL: • e. SHALL CONFORM TO ASTM A36 pp•�� 3p r ME=Cl V[ • N C.P. SEISMIC PIER#1-PATENT #5595366 C b. SHALL BE FABRICATED ACCORD I7C 70 Alsc sPEC1FlCAT1o17s. f, a% e-3/8'xl'91LTS FIELD GRILL HOLES - OPTION OF 4'- 414 TEX STS COACH C OR J BEAN I/4'xP'x4' 3' x 3' PLATE ANGLE 3' W11; 4 - 1/2' SEISMIC BOLTS TYPICAL BEAM CONNECTION X12'. 14'. OR 18'—� PLAN SINGLE WIDE MOBILE COACH Scale: 1' - 10' Not to $Cale 12 SO IN OVERSIZE FOR CHIPPING STAIrLI:S4LML AMI INSERTT 1' 4x4 -4u4 VVF PRECAST FOUNDATION PAD Not to scale 30'x37 PI HOES FOR VY x 2 1/2' CA 18'x24'x3/4' PLYWOOD ELEVATION . NOT TL Cf'I _E MAX 3/4' PLYWOOD SHEETS erocvrn Trx-.cTHER WITH -HWS ALTERNATIVE PLYWOOD FOUNDATION PAD NU G TO SCALE c. SHALL BE WELDED ACCORDING TO AWS SPECIFICATION-. L ELECTRODES: E70 AA33�� W. PLA: ST�MI % ASSY A307 O O y U Iv.THREADED ROD: COIR DRAWN LOW CARBON WELDABLE C d. ALL METAL COMPONENTS INCLUDING NAILS 8 SCREWS EIC. ARE TO BE r�7a a PROTECTIVE COATED. �/ 1 C 0 E8l-RC2 8. THE PIER SUPPORT ASSEMBLIES SHALL BE COATED WITH SHERMAN WIIJAMS OR APPROVED EQUIVALENT. 0 7. THE C.P. SELSIIC PIN BE LISTED ACID "BE= BY CERTIPM TESTING AND � o Q CONSULTING SERVICI� (CTC POR THE FOLLOWING :AADS: U �+ e. LATERAL : 1700 MDS. ULTIkATE WAD I $ W b. VERTICAL : 13000 ULTIMATE LOAD Z > e. THIS FOUNDATION SYSTEM IS FOR PLACING MANUFACTURED BUILDINGS CONSTRUCTED 0 Ot WITH LANGITUDINpALgyOR CROSS JOIafS. LEVEL 0 M 9. SITE WFO1TH NO EXISIItNG S0 PROBLEMS. �E 3 TBL7LEMENTBE NOCCURS DUCTED B TO jPOORYSOD, F=4 • U0 N SEE NOTE 11. d W 10. CHASSIS BEAM SUPPORTS SHALL BE LOCATED AND SIZED FOR - Y THE LOAD AS SHOWN IN THE MOBILE HOME DNSTAILATION INSTRUCTIONS. ^' W E V i1.IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D -V CAN OCCUR. MANUFACTURED HOMES w �' yW W SHALL BE READJUSTED WHEN D.S. EXCEEDS 1/4, OR WHEN IT WILL ADVERSELY AFFECT .!:�0 a, a THE USE OF THE MANUFACTURED HOME. N 12. STANDARD PIER R FOOTING SPACING PER MOBILE COACH MANUFACTURER'S a INSTALLATION MANUAL WITHOUT MANUFACTURER'S INSTALLATION MANUAL f.L� jW�(40 V A SPACING OP STANDARD DETERMINED AND PAD SUPPORTS TO BE DBTERNED BY _ STATE MOBILE HOMES PARK ACT. rn 13.THtS SYSTEM IS ADAPTABLE ACTH HOLLOW MASONRY BLOCK PLEBS. FOUNDATION PAD NOTES 1. THE'FOUNDATION PAD SHOWN 0.4 THIS PLAN 19 A PRECAST CONCRETE FOUNDATION PAD. THIN PLYWOOD F)UNDAT1Otj PAM. :Ay BE usED AS AN _1TER.NATE. 117 Z. FOUNDATION PADS SHALL BE PLeCED ON LEVEL UNDISTURBED SOIL 3. CONCRETE FOUNDATION PAD A. 3000 PSI AT 28 DAYS AS TESTED AND MANUF. BY STARLTTE WEIGHT CONCRETE. v B. PREFERRED PAD ORIENTATION WHERE EVER POSSIBLE 13 THAT THE LONG DIMENSION Of THE PAD BE PERPENDICULAR TO THE COACH BEAM (AS SHOWN ON THE PLAN). C. WHERE FIELD HALF OF THE PADS IN A TRAVERSE LINENS QC I BE ROTATION. ROTATED So HAT THE LONO MORE NG�DIMENSION OF THIN PADS ARE PARALLEL TO THE COACH BEAM. W E" 4. PRESSURE TREATED FOUNDATION A. 3/4 INCH A.P.A. 48/24 EXTERIOR P.S.I.-83 CC. PLUGGED, NER-QA307.PRP-108. COACH SIZE NOTES: U 1. MAXIMUM LENGTH OF SINGLE WIDE COACH 88 FEET. Z O 2. MAXIMUM LENGTH OF DOUBLE WIDE COACH 70 FEET. 3. MAXIMUM LENGTH OF TRIPLE WIDE' COACH 7'0 FEET. 00 d 4. UNLESS APPROVED BY THARP ME' ASSOC.. FLOOR TO RIDGE HEIGHT NOT TO EXCEED: (/J W 0) A A. 8 FEET FOR SINGLE WIDE COACHES. B. !0 FEET FOR 20 FEET DOUBLE WIDE COACH. a CO C. 12 FEET FOR 24', 28', 28' i 32'_ DOUBLE TIMALL ES It ATRIPLE WIDE COACHES W (:) . 8. FOR TRIPLE_ WIDE COACHES. FOLLOW SAME PLACEMENT PATTERN AS ASHOWN ON THE Q.4 1,� (� � DOUBLE - WIDEJMOBIE COACH PIwN: i E .( C0 8. FOR ANY COACHTSfZE OTHWTHAN AS SHOWN ON THIS PLAN OR REFERENCED ABOVE. 1.4 LAYOUT SHALL BE REVIEWED AND APPROVED BY THARP & ASSOC., INC. - 0 z �U) Q NAM � mnww COOP. SBCTION OW QTTE /Y I `IIiBIBLTi!OaCORf..'.CT70N1 NQ[1� ` . � 1L f. }sem Xapj AMPNt _ 13 a . S m 4Aemen Dswtaax F➢OM AeQU �(.4Py O ��uW,�� Aprb Lias dGifoaY 1 LIR ovgoPEsS - E• 11-07-02 /1t749mA6� SCALE, AS SHOW m DRAWN YMW S� r �(ti>s �!%— J� 6 a .Ioes JOB #: 95-36-80 7��y OFCAA`% SHEET, 1 1 I ui