HomeMy WebLinkAbout062-200-024AP 62-20-24 SUGAR PINE STORE ,(Bobby & Kaye Thompson) East Sugar Pine Dr., 50 ft. off Bald Rock Rd., Berry Creek T (REMODELING W/O PERMITS - Bar & Pool Room) C.A.- 62 -20 -24Th g11t1 smear Pine Store, Bald Rock Permit #287-81B,E(remodel/tavern) (replacepo ah deck on store) � 62-20-24 Permit #571-81B(foundation under exis .bldg.) Tavern TTS✓ 62 -?0-24 Permit #2773-$1B(remodel)t-a-vern) 62-20-24 .ROGER ._ROHLER.. -.. �¢��' I/��®�g� 95 Bald Rock Rd, Berry Creek Permit #3923-83B,P,E (conv repair gar to laundry per Special Inspection) 1Cirta./ . 62 0-24 Permit #1104-84E.(ele/propane,disp),__.. 62-20-24 c Permit#1450-86B(reroof/'sore) (-7 6 -t- 0 �1a 'q L 407-66B�` —20-24 0 BUTTE COUNTY DEVELOPMENT SERVICES 'i Complaint Form Complaint Date: Owner: Jct EDI�yaD5ot�1 Address: 2l TRr� C��R Complaint Location: `Z15 PJA LTJ -K -C A. P. * 'CXO?- - d Z4 Zoning: U Supervisorial �\\District: 6 Taken By: jw VIOLATION TYPE: BUILDING HEALTH PLANNING COMPLAINT: 7i �� -0,\ L�-S b -T+' f` G��C �=E-l�prl�S — '1�op�pcp�l.y W 1rD 1: Y�t'1 QTS fCAUTION: Yes No PERMIT HISTORY ON FILE: NONE AS FOLLOWS: FIELD INFORMATION: TENANT: Address: Description of Violation: '7-"T-'5 'e, J-o✓l�l�•z•� �`i Q,;� / / 4 -OTHER COMMENTS: � Approximate Building/Mobile Home Size: _ Approximate Building/Mobile Home Age: _ Under Construction Built by/for: Present Owner _ Has Power Has Gas Written Notice Given & Attached Describe Action Taken: ACTION RECOMMENDED: Information Only, File 30 Day Letter ' -y/10 Day Letter By:-�-- Previous Owner Occupied Date: Has Sanitation Facilities Person Contacted; Hold for Days Complaint Unfounded Other Alm- LO N _ 2 �� Roger L. and Susan Kohler 105 Gamble Road Berry Creek, CA,95916 RE: Code Violations 1215 Bald Rock Road Dear Mr. and Mrs. Kohler: --n81-M1 yr WCVCL.%Jr1V1C1Y 1 ACn V1%.tb 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 February 12, 1996 A.P. #062-20-0-024 This is a courtesy notice to notify you that there is a code violation existing on your property, created by a previous owner. The. violations are as follows: Failure to obtain the required permits, inspections and approvals from this office for installing and occupying three (3) travel trailers and one (1) motorhome. Permits and inspections are required to correct the above noted violation(s). Even though you did not create this violation(s), you as the current owner of record are required to resolve any violation(s) or correct any hazards. Please contact this office to discuss the appropriate correction of this code violation. It is the County's goal to obtain voluntary compliance with the Butte County Code. However, you should be advised that Butte County has an active Code Enforcement Program which provides an effective means of enforcement if voluntary compliance is not obtained. Enforcement may be pursued through the issuance of citations, fines and the recording of a Notice of Violation including a description of the action necessary to abate the violation. You have thirty (30) days to voluntarily comply with the above directions or to present an acceptable plan for abatement or corrective actions to be taken by you. Should you have any questions concerning this matter, please contact Michael Vieira or Scott Rutherford of this office at the address or telephone number listed above. MCV:dms cc: Assessor Yours very truly, Mic el C. Vieira, C.B.O. Manager, Building Inspection r] Cecil Jack and Mary Allen Edmondson 34 Ritberger Road Berry Creek, CA 95916 �ufte co."in LAND OF NATURAL WEALTH 'AND BEAUTY BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 RE: Code Vioaltions. 1215 Bald Rock Road, Berry Creek Dear Mr. and Mrs. Edmondson: September 26, 1995 A.P.#062-20-0-024 This is a formal warning notice. Pursuant to Butte County Code (BCC) Section 41-2, we sent you a courtesy notice dated May 24 ,1994 notifying You that you are in violation of the BCC at the above -referenced location. As of this date, the following violations still exist: Failure to obtain the required permits, inspections and approvals from t this office for. ins alling and occupying three and one (1) motorhome in violations of the Mobil homeravel Parkst Act eof Title 25, California .Code of Regulations, adopted by Section 28A=1 of the Butte County Code as follows: (a).1018 -Permits Required.for any Plumbing or Electric (b) 1018 -Inspections Required for any Plumbing or Electric Installed and occupied three (3) travel trailers and one (1) motorhome in violation of the Zoning Code as follows: (a) Butte County Code Section 24-95--U zone allows one (1) single family dwelling per parcel, g ily The above violations shall be corrected or abated by removal of the travel trailers and the motorhome from the property or converting -them to dead storage. This is your final warning. Unless you contact this office and make the proper arrangements to correct or abate the violation(s) voluntarily, within ten 10 days. from the date of this letter, enforcement shall be through the issuance of a citation pursued said violation(s) and for failing to comply wigthythis warningrlette ourt) for Letter to Cecil Jack and Mary Allen Edmondson A.P. #062-20-0-024 Page 2 September 26, 1995 Upon conviction of said violation(s) or of failing to comply with this letter, the court shall impose penalties (fines) and a Notice of Violation shall be recorded. in accordance with Butte County Code -Section 41-7. The Notice of Violation shall include a description of the premises the violation concerns, a description .of the. violation, the date of your conviction and the action necessary to corrector abate the violation(s): Should you have any, questions concerning this matter, please contact Scott Rutherford or Michael Vieira in this office at the address or telephone number listed above. Sincerely, MCV:dms Micael C. IVieira, C.B.O. Man ger; Building Inspection 1 2 3 4 8 8 7- 8 9 10 11 12 13 14 15 18 17 18 19 20 21 22 23 24 25 28 PROOF OF SERVICE BY MAIL T am: over the age :of 18 and not a party to this cause. I am a resident of -.and employed in the county where the mailing occurred. My business address is: Building Division Department of Development Services 7 County Center Drive Oroville,-CA.`95965 I served the.foregoing. SECOND NOTICE VIOLATION LETTER (062-20-0-024) - by enclosing a true copy in a sealed .envelope and depositing said envelope in the United States mail with postage fully prepaid on 26th. of September 19 __q5 and addressed as follows: Cecil Jack and Mary Allen Edmondson 34 Ritberger Road Berry Creek, CA 95916 I declare under penalty of perjury under the laws of the State of California that the foregoing is true and correct and that this declaration was executed on 9/26/95 at OROVILLE California. Donna Sperling Office Assistant III BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965-3397 TELEPHONE: (916) 538-7541 FAX: (916) 538-2140 May .24, 1994 Cecil Jack & Mary Allen Edmondson 34 Ritberger Road Berry Creek, CA 95916 RE: Code Violations A.P. #062-20-0-024- 1215 Bald Rock Road, Berry Creek Dear Mr. and Mrs. Edmondson: This is a courtesy notice to notify you that you are in violation of the Butte County Code, as follows, at the above -referenced location. Failure to obtain the required permits, inspections and approvals from this office for installing and occupying three (3) travel trailers and one (1) motorhome. Since the additional living units are not permitted in a U zone, the travel trailers and motorhome must be removed from the property or the occupancy and use must cease' and desist immediately and the travel trailers and motor - home be placed in dead storage. (You may check with the Planning Department about obtaining a permit for a mobilehome park.) It is the County's goal to obtain voluntary compliance with the Butte County Code. However, you should be advised that Butte County has an active Code Enforcement Program which provides an effective means of enforcement if voluntary compliance is not obtained. Enforcement may be pursued through the issuance of citations, fines and the recording of a Notice of. Violation including a description of the action necessary to abate the violation. You have thirty 30 days to voluntarily comply with the above directions or to present an acceptable plan for abatement or corrective actions to be taken by you. Should you have any questions concerning this matter, please contact Michael Vieira or Scott Rutherford in this office at the address or telephone number listed above. Si cerely, MCV:dms Mic 1 C. Vieira, C.B.O. Manager, Building Inspection cc: Assessor i .. 4�� o cvnd,�j VIOLATION CHECK LIST u A. P. # Address J2C Owner cya�i/Io�i�S� Owner's Address 3 i - Owner's Phone* No. Supervisoral District �2�cQJ Tenant s Name Phone No. Type of Violation in Detail with Code Section - Priority No. T 7s <e Specific Plot Plan with C/V Noted _yes no Penalties Required 1st. Notice Sent jZ V p? ��. �� 2nd. Notice Sent (� —� ate Date Comments and/or Determination M�` ���►'�- /k°iy�o� �r2� �-'.deo-� sR Disposition For Citation Citation (Date) (Date) Department Recommendation to. Court stir- ir-e 1 2 � � S'/� �-� /�L'� � o� � (��2%ilGiL.Q/ �G�''�IiTLGI /�.C�t:� �� •��C(.� ��� r V�' ���J-e-✓' �e�;✓i ��'o � ... �l/b s�['e-- a%� rc� VIOLATION CHECK LIST j : A.P. # d6�—20d-0� Address (! Cil � Owner ar- - 0kP- �p,, ,1p a,nCNril Fd Owner's Address 3 1C;�iGe i •1 .g A, 116t d 4��vv It, Owner's . Phone" No. Supervisoral District -*: �'j';: • Tenant's Name Phone No. � Type of Violation in Detail with Code Section - Priority No. -- / Date (Date) ' Department Recommendation to Court -Specific Plot Plan with C/V Noted no Penalties Required _yes t 1st. Notice Sent 2nd. Notice Sent ate Date Comments and/or Determination Court Action Notice of Violation -.Recorded (Date) 2 � � S'/� �-� /�L'� � o� � (��2%ilGiL.Q/ �G�''�IiTLGI /�.C�t:� �� •��C(.� ��� 9110S V�' ���J-e-✓' �e�;✓i ��'o � ... �l/b s�['e-- a%� rc� 4r o� f%j A0& emd 0kP- �p,, ,1p a,nCNril Fd i •1 .g A, 116t d 4��vv It, 7 -1-9- Disposition For Citation Citation Date (Date) ' Department Recommendation to Court Court Action Notice of Violation -.Recorded (Date) BUTTE COUNTY DEVELOPMENT SERVICES Complaint Form Complaint Date: Owner: Joc� D)., 0 Io so i Address: '!A t e LeLY- Complaint '?_C Location: A.P.# ,C(OZC) Z' Zoning: U Supervisorial District: Taken By: VIOLATION TYPE: �_ BUILDING HEALTH PLANNING coMPLAINT • Z irR•�a10�. `T�A�-1 I,EiZ-S b � ��"� �-c�PC�T-� P�-S SLS �o�jPR�I y L-40 i�t'1 QTS CAU�TI_O�N • Yes No PERMIT HISTORY ON FILE: NONE AS FOLLOWS: FIELD INFORMATION: TENANT: Address: Description of Violation: -. o OTHER COMMENTS: Approximate Building/Mobile Home Size: Approximate Building/Mobile Home Age: Under Construction Built by/for: Present owner Previous Owner Occupied Has Power Has Gas Has Sanitation Facilities Written Notice Given & Attached Person Contacted Describe Action Taken: } ACTION RECOMMENDED: Information Only, File Hold for Days 30 Day Letter Complaint Unfounded � 10 Day Letter Other By: ( > Y f�^�Z.. ,�.� _ Date: Ow ,?^"t.,'"v`iin -,.+ ',sej}�..` °r 's+�i'•`} ! "s=. -S -F5. �. .-a pr X� *. ='x4+^tH• t. :.ri vw il.1-5 y j`-oY� �Permit��Y45a9-�86�(rrEroof fafiore)a-��� $ P—� 0 6 , a o . ',G' � L} •�'`� 4ib u .. �"k5 - ,^,.a„�^.ccsv_ ' n o ` �+j����C��}�^. n� 1 11 Arr 's- Iv- �� BUIL bE AUG 2 g v- r 7'. COBUIrLp NOG DBP�t� ell:2-oVL " AUG 2 9 1995 ,LIV•P�weJ1R.. Y� ,i.o ce, XC�64, Mn�/>der�rvwwe� nrw-M.wA. �.,,r�n. uw�en, 9n w� ,�,�n➢e e�Q QUA � rma Bze. Aw� ecQ 5661 6 Z end 1d3U JNiaim9 311AS Ao umnoo C�f7br-h355 (6)1.1b) �ihs1, r�J UI�LD G Burro DEPT AUG 2 9 1995 August 20, 1995 To Whom It May Concern: We, the undersigned, are residents of Berry Creek, near the Sugar Pine Bar on Bald Rock Road. We are aware of the owners trying to develop a trailer park in the back area of the Sugar Pine Bar, and would not like it approved. There have been numerous problems relating to people who stay in their trailers behind the bar. There are continuing_q_arties,-general rowdiness,.and-ouns..being shot off. at,all times of the _ night. There are also health concerns, as some of these renters are emptying their sewage and gray water on the ground. We are aware that this is not a state regulated trailer park, and we are concerned that at this time, there are three trailers and no one to oversee their actions. We would like to see them removed. Name G�-Uf9�.J Com' ' �' %✓ , 9. Sincerely, Address f qO ►� � LA 1 Phone c) 6�E7� - 3Z-70 I S-0 I BUTTE COUNTY DEVELOPMENT SERVICES '.Complaint Form Complaint Date: Owner: J.ALK= EDMy ND So Address: 5.4c Rlt TP'TzC�ETz �y CSC- CA 95D 1(0 Complaint Location: `ZI 5 e>N l id Y—C - P -D VIOLATION TYPE: BUILDING �5. A.P.# C(oZ�2.Oa- (� , Zoning: U Supervisorial 'Di\strict: S Taken By: Jw HEALTH PLANNING COMPLAINT: 2- 7P-,-\ IiS12'6 D 0 -Tk� "�'-�'T�l.� - P�o6�st-� w �U 1' ••t'1 QTS PERMIT HISTORY ON FILE: NONE FIELD INFORMATION: TENANT: Address: t - Description of Violation: OTHER COMMENTS: Approximate Building/Mobile Home Size: Approximate Building/Mobile Home Age: Under Construction Built by/for: Present Owner Has Power Has Gas, Written Notice Given & Attached Describe•Action Taken: ACTION RECOMMENDED: Information Only; -File 30 Day Letter 10 Day Letter By: CAUTION• AS FOLLOWS: Yes No Previous Owner Occupied Has Sanitation Facilities Date: Person;Contacted Hold for Days 'Complaint Unfounded Other ADDRESS: PHONE NUMBER: OTHER COMMENTS: COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road,:Chico, CA - (916) 89.1-2751 7 County Center Dive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. L-r'�-� Q V A-tn 7 V COY t2f e 0. 0- A41U, a r� { OVP!/' {/d � 'At/�o+r�n ? e7c, X17 t sof Date 41112-119el Inspector REV 10/9 1450-86 Sugar Pl'n�e Starg 9 �d Rock R:D, BC "e - ia COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICAMN AICD PERMIT PERMIT NO. ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER -. TELEPHONE, SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS - CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS YPermit , rte'. �, fee $ -� PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S I G I W 10.00ea TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation❑ Other ❑ Describe work: Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service e00V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): El I am licensed under provisions of Chapt. 9, Div. 3 of the BUslnes$ and Professions Code and my license is in full force and effect. License No. Classification F1 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ 1, as the owner, am exclusively contracting with licensed contract- ontract- ors. ors.(Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST.(DWELLING OCCUP.& , OR ADDNS. ACC. BLDGS. /20sgft NEW CON5TRMULTI-OUTLET 2.50 ea NON.RESID BRANCH CIRC ITS POWER APPARATUS e (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES 200500 BALM 30 FIXED APLNS. EX. OCCUp. OUTLETS P(RESID )REA.) 1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. byirin 15.00 g Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ Occup. CONST.TYPE I I FLOOD PARCEL 1 PD F_77_[7= This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date Receipt No. � �� WMITE-D.P.W.. YELLOW-ASSF350R, PINK -INSPECTOR, GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS ' 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 - APPLICATTDNAND PERMIT PERMIT NO. �� ASSESSOR PARCEL NUMB — —� ZONING BUILDING PERMIT owNE �% TELEPHO EC — J SQ. FT. OCC. BUILDING VALUATION OWN LING A E 61 CONTR TOR'S NA `^ V TELE NE CON C 'S (LING ADDRESS Fireplace CONSTR TION LENDER UNKNOWN Total Valuation $ Filing Fee $ 1000 LENDE SMAILING ADDRESS Permit Fee $ ARCHITEIC7 OR ENGINEER LICENSE NO.Plan Checking Fee .$ Energy Plan Checking Fee $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS Permit fee $ PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME PARCEL MAP Water piping 5.00 Each qas water heater or vent 5.00 USE OF STRUCTUGas It, 1, ( � SF [:1 Duplex❑ Mobilehome❑ Other SPECIFY piping ;system 1 - 5 outlets 5.00 Building sewer 5.00 Mobile Home S G W 10.00 ea TYPE OF WORK New ❑ Addition [I Remodel Utilities I tallation❑ Other Describe work: R2Contractor Permit Fee $ ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Buslnes$ and Professions Code and my license is in full force and effect. License No. Classification �jFIXED - 1, as the owner, or my employees with wages as their sole compen- i` sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contra ors. (Sec. 7044) ❑ I am exempt under Sec.- Business and Professions Code for this reason NEW CONST. DWELLING OCCUP.ty , OR ACDNS. ACC. BI_ ) h2sgft NEW CONSTR.MULTI-OUTLETNCHCIRCU 2.50 ea NO N.R ESID BRANCH CIRCUITS) POWER APPARATUS .&) SINGLE OUTLET CIR. EX. Occup(OUTLETS OR FIXTURES 2AL0 eLO3090 APPLNS. OR EX. Occup. OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00ct- Misc. Wiring g 15.00 Permit Fee $ WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling g Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to save, inde •fy and keep harmless the County of Butte against all liabi s, • gment c sus; and expenses which may in any way accrue agai s u t on q en a of the granting of this it. X Date Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE occUP. CONST.TTPE I FLOOD PARCEL PD 1 ND 1 ISSUE This permit is hereby issued under si )ns of the Butte County Code and/or work indicated above for hich IREC PUBLIRKS Y PER EXPIRES Date the applicable provi- resolutions to do fees have been paid. Date ' Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR. PI R -INSPECTOR. GOLDENROD -APPLICANT • 4 C A00 y ' Aoo(D . XHAUST HOODS 'QER S�ec�o�a Zoo 13 j 0OTR —1 IE cAe�o�� rZtsc�1A1t1%cn► X115 IISCE� IA S�ECDOO At X003 (P) .v1Mc �o o3ar "APP`S CAq��j �M1'eA�SlOAi ��ioe� Co01U UCS sH AcE ?s a rim 7LEQv►�Q,� � a ... ' } r • , .. p.;,:.1"���rbut:�f::'T✓a4 �t'�`=Ltl7k���il n ,.. �{� .'. �,� ' F •'' _.. _ _ ., r � /�� �c PNvN �y,NP'JSd �c�Pe• . �Qot 0Vnte��� MO S�e�f P�a�e -t Mi ai-')? F40 � g 00F<oteo . 9Fy� ,�s/d agOST type 000 -P- Z %77- W % BUTTE COUNTY BUILDING DEPARTMtNt, APPROVED s y3. 6194 RABCO METAL PRODUCTS INC. Mfrs. of Duality Kitchen, Bar & Restaurant Equipment At'~ 417 East 15th Street Los Angeles, California 90015 (213) 747-5115 I -Effective: 3/1/80 : C� is MfrA, P00"C INC. 417 EAST 15th STREET - LOS ANGELES, CALIFORNIA 90015 (213) 747-5115 RANGE HOODS FOR KITCHEN EXHAUST page '13a Model # Galvanized iron hood, pitched or box type (please specify) , all welded REH-G construction, NSF Approved, with a 2Y" gutter around perimeter_ -with grease relief hole and removable stainless steel grease cup.. i i Up to, and including 48" wide, 21" high: 20 ga. $68.00 per lineal f t . MIN: CHARGE: $ 280.00 i -16 ga. $76.00 per lineal ft. MIN. CHARGE: $ 310•.00 From 48" wide up to and including 60" wide, 21" high:; 20 ga. $ 72.00 per lineal f t . MIN.: CHARGE: $ 288.00 16 ga. $,80.00 per lineal ft. MIN. CHARGE: $ 32.0::.00 � � *For built-in 3" galvanized air space against ceiling, add $10,00per lineal ft. MIN. -CHARGE: $ 42.00 *For 3" galvanized air space against wall, please.,;:." add $10.00per lineal ft. MIN... CHARGE: $ 42:00 Model # Stainless steel hood, pitched or box type (please specify) ; all -welded REH-S construction, NSF Approved, with a 2�" gutter around perimeter ;with grease relief hole,and removable stainless steel -grease cup. +} f„ Up to, and including 48" wide, 21" high: ~„ { 20 ga. -$ 136.00 per ;lineal f t. MIN .,,, .CHARGE : $ 540.:`00 �Y 18 ga. $1,56 00 per lineal. ft. MIN--, CHARGE:. $1620:00 BUTTE COUNTYrom '48" wide:up to and including 60" wide; 21" high, .` ga ,.,$;,146.00 per lineal ft. MIN.,•CHARGE: $ 580:00 7� BUILDING DEPARTty1f ga. t$ 166. 00 per.' lineal f t. MIN. CHARGE: $ 660.`00 AP P R0 , Ef)r built-in 3" stainless air space against ceiling, add $14.=00 per lineal ft. M•IN. CHARGE:-$. ;5.8,:.x00. *For 3" stainless air space against wall, -"please y add -f $,12.=00 per lineal" ft. MIN. CHARGE: $.-,,,O 00 Model #a , ' High velocity hood, all welded 'construction, NSF Approve$,:,made 'of - RHV`H 18 ga.-stainless steel, with a 10" wide stainless steel pl'aie,,shelf, standard 10",'x 20" filters, built-in 3" air space against -wall; and welded -in stainless steel grease' relief tube with removab , siain•- ' .less steel grease pan. $304.00,per* lineal ft. MIN. CHARGE: $,2602.00. ***NOTE: We will do complete engineering of your exhaust and return aix,.'systems, which includes sizing of all *associated components, as a free`�service. �- Just give us if call, or drop us .a line with the pertinent.infozmat • - ALL, ABOVE' PRICES ARE FOB FACTORY +;7.{ " 15" 5" Dimensional Data For Exhaust Hoods SEE 4AAft o%n3 -1f-VT oN *)cIDS cAcP * Z0 gAKQ J�4 3�0------------ FRONT -PITCHED, WALL -MOUNTED EXHAUST HOOD MODEL # REH 15" l variable L 15" 47" IN M atre 'ume . FM VAIM , � Welded -in grease relief tube 10"x20"x2" removable filters 101 1 12" Rern�vable grease pan 1, 91 911 VELOCITY',HOOD`Wiplate shelf and built-in filter bank with filter MODEL # RHVH variable 3" 18" "BOX" TYPE EXHAUST HOOD, with optional built-in 3" ceiling PITCHED "ISLAND" TYPE EXHAUST HOOD air space. MODEL # REH BUTTE COUNTY MODEL # REH �WST&W VS L. LlgTltJCc BUILMN(� DEPARTMENT Aft. maa�n�A�cTN2�iZ s 3 I1 MONs APPROVED 3 RABCO METAL PRODUCTS INC. INfr%Iiforni900152 of Quality Kitchen, Bar &Restaurant Equipment 417 East 15th Street Los Angeles, 13) 747-5115 .z. Woo Owner: Address: BUTTE COUNTY DEPAIST OF PUBLIC WORKS SPECIAL INSPECTION REPORT Tenant:= 10 aA�� Building Location: 0 Cc/ Type of Inspection requested: 77 1. Housing " 4. Other (specify 2. Financing -VL 2�ate of InsDeation Inspector EK3. Change of Occupancy to Present use of building: ��-�✓��-�� ��°` ��eC-� A Sanitation (Housing) 1. Water close t: 2. Lavatory: 3. Bathtub or shower: 4. Kitchen sink: 5. Hot and cold water to fixtures: '..6. Heating' facilities: 7. Natural light and ventilation: 8. Room and space requirements: 9. Bedroom window or door for second exit: 10. Infestation of insects, vermin, or rodents: ' 11. Connectior. to sewage disposal: 12. Connection to water -.supply: 13. Rubbish and garbage facilities: 14. Comanents: B. Structural 1. Piers and footings: 2. Floor construction: 3. Wall construction: 4. Ceiling and:roof construction: 5. Fireplaces:' 6. Comments.• C. Electrical. . t 1. Service ground•_ 2. Recepc: ; . a: ' 3. Fusin,: - 4. Cogmnents: D. Plumb -u . 1. Fixtures connected and vented: 2. Gas water heater: t 3. Gas heating vents: 4.. Comments • l...,nt�n.�crl nn hnrkl'. E Other I. Maintenance and repair,: 2. Fire hazards:.---- 3. Safety hazards:' 4. Weather protection: 5. T.Juderfloor and attic ventilation: 6. Conments: F. CoTwercial Buildin&s 1. Roof covering:_ 2.. Distance to property lines: 3. Physically handicapped: 4. iftest"oom floors and walls: 5. Exits: 6. Improvenants: 8. Comerit.-Z!, G. Field Problems or Viclaions 1. Problem or ;give 2. W h -at act k6,n t a, c7l (givJ V =� 3. WhIat ao-t:J.on recmeended: -/—/ A. -Infor.-aation only - nonT eta descripti011) �pifte d.J escription) T? �BHold for tcn (10.) days, then writ. -L. le.tte 11 /. r- W -,!.-,c. letter. 7 D. Other: W r7 -i / �^ PERMIT NO. 571-81B • PERMIT EXPIRES OWNER B Sugar Pine Store (Bob & Kaye Thompson) CONTR. owner I ASSESSOR PARCEL 62-20-24 LOCATION East Sugar Pine Dr., 50'off Bald Rodk Rd., Berry Creek t% 1W i 1 I a t s Temp. Power Pole Called PG&E = Temp. Elec. Service Called PG&E F Temp. Gas Service ` Called PG&E JOB FINALE[ Signature J = ,OK 0 = Not OK = Not Applicable MOBILEHOMES = Not Ready f MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except k's 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4, Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rig.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elea Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4, Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/0 to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date i� f V = OK 0 = Not OK - = Not Applicable = Not Ready 3_�) -Sd ACS RESIDENTIAL (Single and Duplex) Date UNDERF(L00R Plans OK except #'s Date . FRAMIPJG (Continued) /S�CIs�'� nin requirements -Setbacks -Easements 48. Property Line Firewall & Openings Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits -3 Fig.,Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection ffliw�g, Porches & Decks; Soils -Steel- / /" Ftg. Depth 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers - emwalls, Main; Steel-Blockouts-Wrapped-Slab 52. Siding -Nailing -Veneer -4w-- temwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 54. Glazing Area -Glass Protection -Skylights -Plastic n. n w \ c. i Fittings -Test -2 way C/O -Sewer Test 55. Shear Walls; Nailing -Bolts 9. 'ze-Anchors st-Anchors-Regu lator-Sery ice Test ound s; Clearance -Material -Support -Ins. 1 -s-Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date / Card-B1A-Date Date FINAL (Plans) OK except q's Card -BI to .-$' Card -BI Date Date _ PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 56. Ext. Steps -Door & Sidelight Protection -Landings 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Meth. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access _ 18. Test Tub & Shower, 2nd Floor -Tub Access 61. 62. Elec. Trim & Subpanel; Breaker Sizes -Labels Stairs & Rails 19. Gas Pipe; Size & Anchors 63. Fireplace or Stove; Clearances -Hearth Card -BI Date Card -BI Date 64. 65. Elec. Outlets at Wood Panel; Int. & Ext. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except p's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70. Plb., Elec. & Mech. Equip. Listed for Location 22. Size Boxes & No. of Conductors -Stapled 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 23. Romex Installed Close to Edge of Studs & C.J. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water 72. 73. Insulation -Foam -Looked in Attic E) Yes Guard Rails &Deck Construction -Post Caps _ - 25. 26. 2 Appliance Circuits in Kitchen & Conductor Size Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27. 28. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral CYes ❑No Service -Riser Conductors & Ground -Main Disconnect 75, 76. Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes El No; Planters ❑Yes 0 N Stucco; Brown -Finish 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date Card BI Date 81. Ventilation throughout House Card B -I Date Card -BI Date 82. Glass Protection Date MECHANICAL (Permit) OK except q's 83. Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 31. A.C. Ducts: Insulation & Support 85. Water & Sewer Connected -C/O to Grade -HO Approval 32. Vent Fan; Exhaust above Insulation 86, Energy Compliance Certificate -Other Certificates _ 33. Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic - Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FRAMING(Plans) OK except q's 36. Sills; Proper Material & Anchors Card -BI Date Card -BI Date Comments at Final: _ 37. 38. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound Bearing over Girders & Floor Nailing__ 39. _Walls Draft Stop in Walls (rat proof) _ 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. 42. 43. 44. 45. Header & Beam -Size & Bearing Hangers -Post Caps -Anchors -Connectors Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Ring. Fireplace Ties or Type A Flue -Fireplace Throat Attic Access: Size & Romex Protection -Draft Stop -Ins. Baffles ^ 46. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framing (NOTE: An entry must be made each time you visit jobsite) COUNTY OF BUTTE - DEPARTMENT 0F 7 County Center Drive - Oroville, California 95965 - PUBLIC WORKS PERMIT NO. Telephone 916/534-4541 . r ` Ai APPLICATION AND PERMIT ASS SOR PARC L NU BE Z04ING BUILDING PERMI 7-1lNER mow- M_ v .Y1 V TELEPHONE SQ. FT. OCC. BUILDING VALUATION O R'S AI IN A DRESS ® ~J CONTRACTOR'S N ME TE EPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER P_ UNKNOWN Total Valuation $ Filing Fee $ *10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ ,10D Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ oO BUIL I ADDSR_VS n f QJ PLUMBING PERMIT FilingFee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. SUBDIVISION NAME PAR EL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF ❑ Duplex❑ Mobilehome❑ Other �er'�l SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OF WORK New Addition❑ emodel UtilitiesQ Installation❑ ther Describe work: V Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600v OR LESS 100 AMP OR LESS 5.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. (DWELLING OCCUP.51) OR AODNS. \ ACC. BLDGS. 20 sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): El am licensed under provisions of Chapt. 9, Div. 3 of the BusinessOccup(50 and Professions Code and m license is in full force and effect. y License No. Classification �(C 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR .OUTLET 2.50 ea NON-RESID BRA CH CIRC ITS NEW CONSTR. (POWER APPARATUS &I NON-RESID. `SINGLE OUTLET CIR. a 25C Ex. OUTLETS OR FIXTURES BAL01 FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESID,) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shal I be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee S Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County i onsequence of the granting of this permit. ss�� X Date ` rX 6 — Signaturepplicant — caner � Contractor [:]Agent ❑ An OSHA ermit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OCCUP. GROUP I TYPE OF CONST, I PA EL P I HD ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIR TOR PUBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date •_ Receipt No. g78-7 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT -,n�.�`!'^�v.:w.-n:�.n,•,:-ya:�ii' �'o":-�,'7».+'^^�1.-,.+"i.:T."4;.n.w, .+:..',y,�r, w,.r ry,^.v;.vri.wC'�pl�..•r�wx+«-Lw w.� ,.. � ,.--,.... ---- - - - r• COUNTY OF BUTTE.- DEPARTMENT OF PUBLIC WORKS - BUILDING DIVISION �7 COUNTY CENTER DIiJVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE: 9'16/534-4541 PERMIT APPLICATION DATA SHEET 3 Permit No. OWNER_�" A. P. No. Proposed Building Use Permit Fee Based Upon: Complete Contract Price DPW Valuation 0 h .r_( plain) Building Inspector Date At time of permit application, I was advised thv following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED APPROVED r/ 1. All items have been submitted. . . . . . . . . . . . 2. Plot plans in duplicate/triplicate. . . . . . . . . . . 3. Complete plans in duplicate/triplicate. . . . . . . . . 4. Complete engineered plans and calcs: . . . . . . . . . 5. Plans with Energy Design Compliance Statement. . . . . . 6. State Energy Forms No. 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ . . . . . . . . 9. Letter of signature authorization. 10. Sanitation approval from Health Dept. 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. . . . . . 13. Contractor's License Information (no., name style, classif.) 14. Owner -Builder Verification (Given to owner❑, Mail to owner ❑ ) 15. Improvements may be required. . . . . . . . . . . . 16. Mobi lehome Installation Data. . . . . . . . . . . Pre-Inspec. request to 17. Pre -Inspection for Required. Building Inspector (Dote) 18. Other When you issue the permit, process as follows:_ Mail to owner. Mail to contractor. Telephone and hold for pickup at office. Deliver w/inspector. 'Other Applicant Date rZ "2 6—,,5Y -r v Copy of plans sent Health Dept., Fire Dept., Other Date During the plan checking process, the following data must be submitted prior to permit issuance. (For required items not checked above at time of application, circle item.) 1. Index permit for above Items No. 2. Additional items required: (Contractor, Designer, Owner) was advised of above required data by Telephone Mail Other By Date Plans Plans Other: Copy—DPW COUNTY OF BUTTE - Deportment of Public Works 7 County Center Drive, Oroville, CA. 95965 Phone: 916-534-4541 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information in the envelope provided at your earliest opportunity to avoid unnecessary delay in processing and issuing your build- ing permit. No building permit will be issued until this verification is received, 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no). 2. I (have/have not) t42- signed an application for a building permit for,the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction: Name Address City_ Phone Contractors License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractors License No. 5. I will provide some of the work but. I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Y Signed: Property Owner 461A Social Security numbe __I' S Date 2� —a 0—F1 NOTE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. ' • i ',Sy � e R-pi�4° -_,�-� �k>�,'__-•- - __ -- _ All_M�ter '�c?�Ko kmanship_Sha11_Be-ia'-= F - i7D7 G -Si. _�yo' ► '1 /accordance wrlh Recognized Good Prcictices and i X �D- - of-c-quality,-Prescrrbe-c far-th -S 6elfied us-eII the— Uniform B i i 41 �'ng. F umbina.&.1�Aechanical-Codes-ar�d-- _ the Natioal Electrical Ao posteruo._.. �� PoSfis y - e ly- %I N —_ GAS -17 10 — .............. 1 � � a q �� /� '��M „� • - .,: _ . -- - --- -- BUTTE -COUNTY' -- -----_ . -- .� . ; = ; r_t�_:?/,�5�!��_�.•`—RUItD11G _—___V4_�� Tv _� iA _ p� _{�•/+ 1 .lam �s�� `�__ :''� _�..`- �i� ♦-- _x..�f: ,�._.._k-..a,._..ir':i �l,�!Ga! _IAl•�YQ I.d�.�.%�-Li.C__'� • t -r• t-� ^':}-S'�"• PERMIT NO. 2773-81B . ^PERMIT EXPIRES OWNER Sugar Pine Store(Bob Thompson) CONTR. owner ASSESSOR PARCEL 62-23.24 1 LOCATION East Sugar Pine Dr., 50'off Bald Rock Rd., Berry Creek r�. tn. I x. P Y` Temp. Power Pole Called PG&E Temp. Elec. Service i Called PG&E Temp. Gas Service I Called PG&E JOB FINALED (Date) Signature V = OK 0 = Not OK- - = Not Applicable * = Not Ready - MOBILEHOMES MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except #'s Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors - 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails^ 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card, -BI Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/0 to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip, w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date -T'- = OK = Not OK = Not Applicable = Not Ready RESIDENTIAL (Single and Duplex) Date UNDE OR Plans OK except #'s Date FRAMING (Continued) o requirements -Setbacks -Easements 48. Property Line Firewall & Openings -. rni17� `F-tg-Depth 49. Ext. Doors -'One 3' -Check Garage -3rd story, 2 exits 3.. ept 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection tg., Porches & Decks; Soils -Steel- /" Fig. Depth 51. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 52. Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 55. Shear Walls; Nailing -Bolts 9. Gas Pipe; Size -Anchors 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except N's Card -BI Date Card -BI Date Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 56. Ext. Steps -Door & Sidelight Protection -Landings 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. 61. G.F.I. & Bath Fixtures & Tub Access Elec. Trim & Subpanel; Breaker Sizes -Labels 18. Test Tub & Shower, 2nd Floor -Tub Access 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. 64. Fireplace or Stove; Clearances -Hearth Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except p's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70, Plb., Elec. & Mech. Equip. Listed for Location 22. Size Boxes & No. of Conductors -Stapled 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 23. Romex Installed Close to Edge of Studs & C.J. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 72. Insulation -Foam -Looked in Attic E] Yes 73. 74. Guard Rails & Deck Construction -Post Caps Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 25. 2 Appliance Circuits in Kitchen & Conductor Size 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral []Yes El No 75, Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑Yes ❑No 28. Service -Riser Conductors & Ground -Main Disconnect 76. Stucco; Brown -Finish 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77, A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Date Card -BI Date 81. Ventilation throughout House Card B -I Date Card -BI Date 82. Glass Protection Date MECHANICAL (Permit) OK except N's 83. Corrections from Previous Inspections 84. 85. Gas Test -Meters Tagged; Gas -Electric Water & Sewer Connected -C/O to Grade -HD Approval 31. A.C. Ducts; Insulation & Support _ 32_ 33. Vent Fan; Exhaust above Insulation Condensate Drain & Overflow; Size & Grade 86. Energy Compliance Certificate -Other Certificates 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic - ------ Card -BI Date Card -BI Date Card -BI- _Date Card -BI Date Card -BI Date Card -BI Date Card-BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except p's 36. Sills; Proper Material & Anchors Comments at Final: 37. _ Studs -Nailing, Spacing & Bracing -Plates -Sound _ 38. _Walls; Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) _40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub _ _ 41. 42. 43. 44. 45. 46. Header & Beam -Size & Bearing Hangers -Post Caps -Anchors -Connectors Cl ng. Joist-Rft_r. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfng. Fireplace Ties or Type A Flue -Fireplace Throat Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions _ 47. Garage Fire Protection Framing (NOTE: Anentrymust be made each time youvisit jobsite) " COUNTY OF'BUTTt - DEPARTMENT OF PUBLIC WORKS r 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 . . - APPLICATION AND PERMIT PERMIT NO. —9 Z _A AS O PARCEL NUMBEEt ZONING qTL P _Nt .L BUILDING PERMI OWN R TELEPHONE �' ' Q. FT. OCC. BUILDING VALUA ION !/� d O O R S MAILI G AD S �� CONTFIACTOR'S NA E TELEPHONE G CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Q Total Valuation y _Q O Filing Fee Q $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ _O d ARCHITECT OR ENGIN R LICENSE NO. Plan Checking Fee •$' 2r -0e2 Penalty $ ARCHITECT ORENGINEER'S MAILING ADDRESS Permit fee $ p (� BUIL ING ADD E S N19,it ��� q-5-fl� PLUMBING PERMIT Filing Fee 10.00 •le y� A R — Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. SOB151VISION NAMEPARCEL MAP Each gas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF ElDuplex❑ Mobilehome❑ OtherI(fT'TAVER, SPECIFY Building sewer Lawn sprinkler system 1 1 5.00 TYPE OF WORK New ❑ Addition ❑ Remodel W Utilities ❑ Installation ❑ Other ❑ Describe work: _,ExiC 10 -6 -ea gk6Ai-' & ie C 4- , IQ4,AiA•P`e �. {-f��J� /�►dNC �J �,�� S'LA Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service s00v OR LESS 100 AMP OR LESS 5•00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. (DWELLING OCCUP.y) OR ADDNS. \ ACC. BLDGS. 2¢ sq ft CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No: Classification 1, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR. .OUTLET 2.50 ea NO N•RESID BRANCH CIRC TS NEW CONSTR. IPOWER APPARATUS S1 NON.RESID. ISINGLE OUTLET CIR, i Ex. Occup OUTLETS OR FIXTURES a �@1 250 FIXED APPLNS. OR Ex. Occup.(OUTLETS (RESID,) EA.1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT Filing Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. against s 'd Count i consequence of the granting of this permit. �� X Date Z —,P/ Signatureo Applicant — Owner � Contractor ❑ Agent F-1 An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories inheight. Mobile Home Installation Fee $ T . �-• IV � —. (� This permit is hereby issued under sions of the Butte County Code and/or workindicated above for which DIREC O OF PUBLIC By PE T EXPIRES Date _ the applicable provi- resolutions to do fees have been paid. WORKS Date•--/� — / —/r�� Receipt No. .5 � / 3 O WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT PEP.MIT NO. _ / 3923-83B,P,E t PERMIT EXPIRES 102 OWNER ROGER KOHLER CONTR. OWNER ASSESSOR PARCEL 62-20-24 LOCATION 95 Bald Rock Rd, Berry Creek 1 S Temp. Power Pols- . 'F OFFICE, Called PG& Temp. Elec. Seri x *� i Called PG Temp. Gas Servi ELECTRIC Meter ,By— Cal led PG&E' JOB FINALED (D Signature J V = OK 0 = Not OK = Not Applicable MOBILEHOMES * = Not Ready 4 MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support -Sketch 2, Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/O -Concrete _ 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) _ 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing_ 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /" LPG 7. Utility Clearance 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors, 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date _ POOLS (Plans) OK except k's 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test-Demand=Valve-Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances _ 4, Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test=Fall-Flex Connector 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enclosures -Panel boards -Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date J = OK 0 = Not OK = Not Applicable * = Not Ready RESIDENTIAL [.Single and Duplex) Date UNDERFLOOR Plans OK except #'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 'rewall & Openings 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth_6Q__S1&LL �Wi -Headroom-Rise-Run-Landing-Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 5; on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab Siding -Nailing -Veneer mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 64 4+f ri++g Area -Glass Protection -Skylights -Plastic _ 8. D.W.V.: Fall -Fittings -Test -2 way C/0 -Sewer Testar alts; Nailing -Bolts 9. Gas Pipe; Size -Anchors 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI aCard-BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except H's 66--&M-Steps-Door & Sidelight Protection -La Card -BI Date :Jff-PLUMQINB-(Permit) Date Card -BI Date OK except p's 57 _ Wat t.; Vent- Access -Combustion Air 58. Furnace• arance-Comb. Air -Connector- rage; Above Floor -Ducts -Meth. Protection -- Water ; Test & Anchors -Nail Protection Test-Fttngs & Anchors -Nail Protection 59 1-AZ-Str0v&4-Paft-Test, First Floor -Tub Access 60. C F '-�' t rPc R Tuh cess _ 18. Shower, 2nd Floor -Tub Access ec. Trim & Subpanel; Breaker Sizes -Labels 19. Pipe; Size & Anchors 62..S1ai ;-8r (sails -' - 63. Clearances -Hearth 64. 65. Flar O ler ger, - ; Int. & Ext. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance C Erl Dat et- Card -BI Date Card -BI Date Card -BI Date 66. s at Kit. Counter Date ELECTRICAL Permit OK except q's 67. Gacage_Eise-gee.-Sr: ng- ming -Closer 68. A.C. Du - per 20. Fixture & Transformer Clearance -Ins. Protection r. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In G r -,Above Floor-Mech. Protection -- - .Receptacles Spacing -Lights &Switches at Doors 7 v Ib., Elec. &Mech. Equip. Listed for Location 1 let Receotarlac in Garage; (G.F.I.)-Romex Protec. on- oam Looked in Attic ❑Yes ?�me s & No. of Conductors -Stapled 23--,Ko-me tailed Close to Edge of Studs & C.J. 4. quip. Ground made up w/Mech. Fasteners -Bond Gas & Water 73 _ tinction -Post Caps 2 Bits in Kitchen &Conductor Size ee Ire I / ga. Cu or AI-A.C. Wire Size / / ga. Cu or AI 74. Fdn. o Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27 g�'Cu or AI -Oven Circ. / / ga. Cu or At, Insulated Neutral `Yes ❑No 2 - Iser onductors & Ground -Main Disconnect 75. FOIIowja rive ❑Yes ❑ No; Walks EJ Yes ❑ No; ers 1:1 Yes ❑No 76 -_- _ 2 nets-Motors-Mech. Equip. 77, net - es-Brkr. & Cond. Size -115V Outlet _ 30. - ower Light - nts Above Root; Plbg.-Ap liance-Firepl.-Clearance to Opngs. _ ----.- �j��ard BI Date -_ l Prd-B-I Date Card -BI Date 79.' ; sconnect, Electrical, Plumbing 8 erior lec. Trim; G.F.I. Receptacle -Underground 8 ilat'on throughout House ass Protection Date MECHANICAL (Permit) OK except #'s84. 3 orrections from Previ p t' ns , 8 86. G e t -Meters Tag s -E ectric a er & Sewer C cted-C/O to Grade -HD Approval n icate-Other Certificates - _ 31. A.C. Ducts; Insulation & Support - 32.Vent Fan__Exhaust above Insulation 33. Condensate Drain _& Overilow; Size & Grade Card -BI- Card -BI 34. Furnace -Vent: Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Date - - Card-BI� Date Date Card -BI Date -B I Date Card -131 Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date _(rat FRA (PI ) OK except q's aterlal & Anchors _ _ o. �ringj_W_alls _37.ailing, Spacing & Bracing -Plates -Sound 3_over_Girders & Floor Nailing - proof) 4.0ilings-Stairs-Chases-Tub Comments at Final: Header & Beam -Size & Bearing 4 - ost Caps -Anchors -Connectors 4,3. ail g-,4efST--711r: Ses-Purlin-Roof Brac.-Truss-Shthnq.-Rfnq. 44. ,&.*�Type A Flue -Fireplace Throat 45. At+is-AeeQSS'Size & Romex Protection -Draft Stop -Ins. Baffles 46. ows or_Exiting_Doors-Sill Hgt. & Dimensions 47. on Framing _ (NOTE: An entry must be made each time you visit jobsite) COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This building has been constructed and completed in accordance with the requirements of the Uniform Building Code under permit number 3923-83 for the following: Use Classification Laundry Ruil.ding Address or Location 99 Ra 1 d Rork Rd, Rerry Creek Group B'2 occupancy; Type V -N construction. It is hereby certified for the occupancy described above and may be occupied. Director of Publ' -W rks Date 1/30/84 By POST IN A CONSP11C000S PLACE (Over) t, - COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville,-California 95965 - Telephone 916/534-4541 APPLICATION' -AND PERMIT PERMIT NO. ASSESSOR PAR NUMBER ���/ ZONI BUILDING PERMIT OWNER•D�r^,gyp+ / PLQ/aae TrELEPHONEL ✓�����t7 S0. FT. OCC, BUILDING VALUATION V OWNER'S MAILING ADDRESS G CONTRACTOR'S NAME TELEPHONE CONTRACTOR'S MAILING -ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ 10,ep ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ /57,00 Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ 640 BUILDING ADDRESS PLUMBING PERMIT Filing Fee 10.00 (^ ' J V Each Trap 2.00 /Q. � Solar Water Heater 20.00 e Water piping 5.00 5-; v-0 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 ,0'0 Gas piping system 1 - 5 outlets 5.00 _05-c" USE OF STRUCTURE SF ❑ Duplex ❑ Mobi lehome ❑ Other og!A&�ip%� . SPECT FY Building sewer 5.00 S Mobile Home TS7G W 10.00 e TYPE OF WORK New,Z Addition ❑ Remodel R Utilities ❑ Installation ❑ Other ❑ Describe work: �AYP6A9610A1e 4A94445 TD M►— Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 0ov OR LESS 1 100 AMP OR LESS v'0 10.00 /d. Main service EA. ADD'L 100 AMP 2.50 .30 NEW CONST. DWELLING OCCUP.& OR ADDNS. ( ACC. BLDGS. 2/20sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ 1 am licensed under provisions of Chapt. 9, Div. 3 of the Bus,ness and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- T sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR U TI.OUTLET NON -RESID BRANCH CIRCUITS) 2.50 ea5r NEW CONSTR POWER APPARATUS &'\ NON-RESID. SINGLE OUTLET CIR. / Ex. Occu /o TS P\ XOR FIOR F1 20Q50C 6 L®30 FIXEDD EX. Occup. OUTLETS (RESID.) EA.) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all li rd, c sts es which may in any way accrue said e nce he anting of this permi . %� Date Signature o Applicant — Owner E] Contractor ❑ Agent �An`OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structuress over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ ��<<J� .Xup. ORouP 2 TYPE OF 1/�//ag ARc�L PD ND IssO� This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUBLIC By. PE T EXPIRES Date- the applicable provi- resolutions to do fees have been paid. WORKS Date )/1— Y1T tea' Receipt No. v /S2, WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT � iFile No. BUTTE COUNTY (For Action 1, 2,3) Public Works Dept. (For Information ✓) 1 Director Dep. Dir. ( Sec. i Rd. & Br. Mtce. 1 Shop & Yards I Bldgs. & Grnds. I Bldg. Insp. Admin. t Design Engr. Bridge Engr. Constr. Engr. Surveys Mapping � i Transp. Land Day. iDrng. /S.I. t ; Sub. & Pcl. Maps Permits I Addr. F- J Roger Kohler 95 Bald Rock Rd. Berry Creek, CA 95916 Dear Mr. Kohler: November 17, 1983 RB Special Inspection #51-83 , AP #62-20-24 With reference to the above subject and your proposal to install a laundry in a portion of the garage and storage building behind the Sugar Pine Store, the requested inspection was made on November 15, 1983. The inspection revealed the following items which'must be done or resolved: (1) Verify building anchored properly with foundation bolts or provide slot type anchors. (2) Provide additional 4x12 headers across the room to limit the span of the 2x6 rafters to approximately 10'. (3) Remove all surrounding ground in contact with the wood siding, provide an adequate drainage system around the building and make the building weathertite. (4). The building -must be rewired and plumbed to meet code requirements. (5) The building must be accessible to the phys4cally handicapped. (6) The sewage disposal system must be approved by the Butte County Health Departmenti it is now in order for you to submit three copies of floor plans and plot plans and apply for the required permits and pay the appropriate fees. In addition to the above, our records indicate there are several permits on the main building which have not received final inspection and approval. When our Building Inspector is on the property inspecting the above work, please review the other permits with him and see if we can final these permits. An additional permit should be obtained if further items of work remain -to be done. Roger Kohler (RE: Special Inspection #51-83, AP #62-20-24) November 17, 1983 ' Page 2 Should you have any questions concerning this matter; please contact this office. Yours very truly, Clay Castleberry Director of Public Works Origirml signed BY.' J; R Glander. J.F.: Glander :. JFG:aj Chief Building Inspector 1 ' BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS SPECIAL INSPUTION,REPORT Owner: Ze—���l���d'S A. P. # Address: Date of Inspection' Tenant: Inspector -� Building Location: %a e �. ,�, S'••c�, {l�' Type of Inspection requested: 1. Housing ".2. 2. Financing 4. Other (specify) Present use of building: / / 3. Change of Occupancy to A A. Sanitation (Housing) , 1. Water closet: 2. Lavatory: 3. Bathtub or shower: 4. Kitchen sink: ._� 5. Hot and cold water to fixtures: 6- Heating facilities- (!!E::) acilities:® Natural light and ventilation: 8. Room and space requirements: 9. Bedroom window or door for second exit: 10. Infestation of insects, vermin, or rodents: i�. Connection to sewage disposal: /-�e,✓! h. ,(�,� �. 12. Connection to water supply: 13. Rubbish and garbage facilities: 14. Comments: r CC) Structural G4r.�� 1. Piers and footings: 2. Floor construction: 3. Wall'construction: 4. Ceiling and roof construction• Z :a 6. Comments: !.1-,,.aL-� — 2./ LO 7. Electrical 1. Service and ground: 2. Receptacles: 3. Fusing: 4. Comments: Is Ia E. Plumbing 1. Fixtures connected and vented: 2. Gas water heater: 3. Gas heating vents: 4. Comments: Other 1. Maintenance and repair: 2. Fire hazards: 3. Safety hazards: 4. Weather protection: 5. Underfloor and attic ventilation: 6. Comments: C ercial Buildings V Roof covering: /!/i��✓C_ 2. Distance to property lines: OC�� Physically handicapped: 4. Restroom floors and walls: 5. Exits: 01 e-- 6. Improvements: _;O� 7. Zoning: .4- z 8. Comments: G. Field Problems or Violations 1. Problem or violation (give complete description): 2. What action taken (give complete description): 3. What action recommended: / / A. Information only - file. / / B. Hold for ten days, then write letter. %7 C. Write letter. / / D. Other: r.,;�...-i-r.�-•�-�i-.,�.._r;.,:,.✓`•c:: �-�--..'-"tin: i.+:. �""�"s"'��.Y.��. .-.+.� r� .n;. �y.`�•.�, -�_ -., ..... _ _. -r.,� _ � . ter, ,.._ _r y .. � �. s, COUNTY OF BUTTE - DEPARTMENT 'OF PUBLIC WORKS aj 7 County Center Drive - Oroville, California 95965 Telephone: 534-4541 ' APPLICATION FOR SPECIAL INSPECTION Owner &QG-7F_L_ lZ,6f%LEP A. P. No. Mailing Address �j �CJ�1�-� ��,4 15Eel-- OVL��- Telephone No 157p Applicant F06EP �_'d HLESA2 Telephone No '5e/ ZS 7`- Mailing Address 9�;I 6171D P-0, 6L RIP. %&foc_� 1 6�4 y S cJl6 Building Location 867141/V D ,SU 611 /G.. 5 76i° '�5 I hereby request a special inspection of the following building: / / 1. Dwelling (if only a portion, specify) / / 2. Apartment House (if only a portion, specify) /_1 3. Commercial (specify present occupancy) 4. 4. Other (specify) 41144' 6r I am requesting a special inspection for the purpose of: / / 1. Moving the building. 2. Financing (specify agency) Case No. 3. Change of occupancy to 1_14kk(pry /'(i1/I/ . (lAyee IC) / / 4. Other (specify) I hereby certify that I will obtain the necessary permits and make any necessary corrections, alterations, or repairs required by the County of Butte, as a result of this inspection, to comply with building and housing code requirements. I also certify that prior to the use or occupancy of this building, I will complete the above required corrections, alterations, or repairs, or, if the building is presently occupied, I will complete the above required corrections, alterations, or repairs within thirty (30) days. I certify that I have read this application and state the above information is correct and hereby authorize-repFesentatives of the County of Butte to enter upon the above-mentioned property for inspectiopurposes., Date (Signature of Owner Fee paid $ 50.C -1f) 1st -DPW - 2nd -Inspector - 3rd -Applicant Receipt No. 676/5rr"lS I " <; COUNTY OF BUTTE - DEP,, F TMENT OF PUBLIC WORKS - BUILDING VISION 7 COUNTY CENTER DRIVE - OROVIL`•LE, CALIFORNIA 95965 - TELEPHONE: 916/534541 / PERMIT APPL'ICATION`bATA SHEET Permit No. OWNER A�4(t' A. P. No. 6Z" ` Z�Z/ Proposed Building Use Permit Fee Based Upon . Complete Contract Price '� DPW Valuation r r Other (Explain) ' r Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing /r and/or issuance: DATE RECEIVED APPROVED 1. All items have been submitted. . . . . . . . . . . . 2. Plot plans in duplicate./triplicate. . . . . ' . . . . . . 3. Complete plans in duplicate. /triplicate. . . . . . . . . 4. Complete engineered plans and-calcs. . . . . . . . . . . 5. Plans with Energy Design Compliance Statement. . . . . . 6. State Energy Forms No. 7 Statement of Intent for Non -Heated and AC Buildings. 8. Fees of $ , . . . . . . . 9. Letter of signature authorization. . . . . . . . . . . 10. Sanitation approval from Health Dept. 11. Planning approval for (A) Use: (B) Parking: 12. Certificate of Workmen's Compensation Insurance. 13. Contractor's License Information (no.,,/name style, classif.) 14. Owner -Builder Verification (Given to owner❑❑,) ' '�"` Mail to owner 15. Improvements may be required.• . . ., 16. Mobi lehome Installation Data. . . . . 17. Pre -inspection for f t -,Re uired.,Pre-Inspec. request to (Date) p t; q Building Inspector 18. Other When you issue the permit, process as follows: Mail to owner. Mail to contractor. Telephone and. honor pickup atoffice. Deliver w/inspector. Other ----� Appl icant / Date i r V- ' 7y Copy of plans sent Health Dept., Fire Dept., Other Date _During the plan checking-process.,.,the_followi ng 6ata,must be 'submitted pr-i,or,to permit issuance: (For required items not checked above at'time of -application, circle item:) 1. Index permit for above Items No. 2. Additional items required: (Contractor, Designer, Owner) was advised of,above required data by Telephone Mail Other By Date Plans checked by Date Plans approved by Date Other: i T K _Copy -IDP W" r. Mi Owner: Addrea BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS SPECIAL INSPECTION REPORT Tenant: Building Location: Type'of Inspection requested: . a 1. Housing.L( 2. F anc 3. Change of Occupancy to 61 f� 4. Other ( specify) Com) z B Date of Inspection Inspector--- 'Present nspector�'Present use of building: A. "Sanitation (Housing) ; 1. Water closet:. 2. Lavatory: .. . 3. Bathtub or shower: . 4. Kitchen sink: 5. Hot and cold water to fixtures: . 6. Heating facilities: - T.- Natural -light and. ventilation: - 8. Roam and space requirements: ' =9..' Bedroom window or -door for• second _exit: IOJ— Infestation of -insects', vermin, or rodents: • ' 11. CoXnecti.or to sewage disposal: 12. Connection to wate:r- supply:, 13. Rubbish and garbage facilities: '14., ing A. P. # .Comments: ' B. Structural • 1. Piers and footings: 2. Floor construction: - -, .. 3. Wall construction: 4. Ceiling and roof construction: ' 5. Fireplaces: -" 6. .Comments C. Electrical. • 1. Service `and ground:_ - • 2. Receptacle^• " 3.. Fusing: 4. Comments: - D. Plumbing � .. • 1. Fix tures connected and vented: . 2. Gas water heater: 3. Cas hearing vents: - 4... Comments • . E. Other 1. Maintenance and repair: 2 ., Fire hazards:.---- 3. azards ____3. Safety hazards:' 4. Weather protection: S.. Yjn.derfloor and attic. ventilation: 6. Conn ents: F. Conmercial Buildinfis 1. Roof covering: 2. .Distance to property lines: 3. Physically handicapped:. 4, "est-oom floors and -galls: 5. Exits: 6. Improvements: 7. Zor_ir.g: 8. Cotnm2nt- G. Field Problemis or Viola ions_ 1. Problem violation ive ^ompleta. description): 694, 2. What action,taken (give caump? 3. What ac r 7.;tfn recce en %% A. "'.nfor..a::ti.on only Hold for tcn (10) days, / / r- Write latter. /-7 D. other: G �� i `e 94 t -o �6er.;� t,ien wri,��: I.� ter. W ,Z m 287-81B,E PERMIT NO. + PERMIT EXPIRES �� bo HOL OWNER Sugar Pine Store (Bobby & Kaye Thou; ' CONTR. owner ASSESSOR PARCEL 62-20-24 LOCATION East Sugar Pine Dr., 50'off Bald Rock Rd., Berry Creek {i �• o { I t 7 Y t• ,,,,. Temp. Power Pole Called PG&E s 1 . Temp. Elec. Service j Called PG&E 3 Temp. Gas Service Called PG&E JOB FINALEEDD GBtrr-- 4 - Signature ✓t- i 1. J = OK , 0 = Not OK ='Not Applicable ' MOBILEHOMES * = Not Ready MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2: Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rig.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location -Test -Wrap:/ /"L"ft./ P'Nat. or/ /"L"ft./ /"LPG 7. Utility Clearance 6. Carports; Windows -Doors 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except N's 1, Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector._ 5. Elec.; Pool Lighting; 15 volts-GFI 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/0 to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged B. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes- Enc losures-Panelboards-Ins. to Main in Conduit 9. Exits; Insp.-Sketch 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B-1 Date Card -BI Date Card -BI Date Card -BI Date Card B-1 Date Card -BI Date Card -BI Date Card -BI Date = OK = Not OK = Not Applicable = Not Ready RESIDENTIAL (Single,and Duplex) Date UNDERFLOOR Plans OK exce t#'s Date FRAMING Continued 1. Zoning requirements -Setbacks -Easements ro Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth xt. Doors -One 3' -Check Garage -3rd story,.2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth -60r-6.tairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -S el- / /'' Ftg. Depth -51--Mywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel -Bloc uts-Wrapped-Slab MT -Nailing-Veneer 6. Stemwalls, Garage; Stee I -RTockouts- rapped -Slab --53."STQOco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ft .-S I 11 -1=717132ing Area -Glass Protection -Skylights -Plastic B. D.W.V.: al Fitting t-2 w O -Sewer Test --&S- shear Walls; Nailing -Bolts 9. Ga ize-An rs 10. Aat ipe; a nchor - e a r Service Test 11 t ' oun 12. On & ucts; r c -Material-Support-Ins. 13. Girders Sills-Ancho Bolts -Joists -Vents -Cripples Card -B t Card BI Date Card -BI Card -BI Date 7 Card -BI Date Date Card -BI Date Card -BI Date Card -BI Date Date FINAL (Plati.4 OK except k's Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except q's 57 or 14. Water Ht.; Vent -Access -Combustion Air 58. Furnace; Vents- - omb. Air -Connector - I ge; Above Floor-Ducts-Mech. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59 8-- 17. Shower Pan; Test, First Floor -Tub Access 60. _ ix ures & I ub Access 18. Test Tub & Shower, 2nd Floor -Tub Access Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors airs & Rails 63. PiFB131888 @F Siever64earjMes-Hearth 6 ood Panel; Int. & Ext. Card -BI Date Card -BI Date Ki & Appliance; Grnd.-A -Cooks earance Card -BI Date Card -BI Date 67. Elec. Outlets & Receptacles at Kit. Counter i ing- Land ing-Closer Date ELECTRICAL Permit OK except p's 68. Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In or-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70. P ec. 9 Equip. Listed for Location QLISize Boxes & No. of Conductors -Stapled 71. c. eceptacles in Garage; (G. F.I.)-Romex Protec. Romex Installed Close to Edge of Studs & C.J. =T -Equip. Ground made up w Fasteners -Bond Gas &Water 72. I ioaetrfHiri�Bm-Looked in Attic E] Yes `2'S�Appliance Circuits in KiKitchentchen &Conductor Size 73. GuaR-Rens-&Deck Construction -Post Caps 2 Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 74. Fdn. Venc'rawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes ••-Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral ❑Yes El No 75. 76. F win instl Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters Yes ❑No Stucco; Brown -Finish - 20 --ft 'ce-Riser Conductors & Ground -Main Disconnect •.29.�'MW. Clearances; Panels-Motors-Mech. Equip. 77, ct-Clrnces-Brkr. & Cond. Size -115V Outlet 86--6+ethes Closet Light -Shower Light Plbg.-Appliance-Firepl.-Clearance to Opngs. ater isconnect, Electrical, Plumbing 81, erior Elec. Trim; G.F.I. Receptacle -Underground ouse Card B -I _ Card -BI Date Card B -I Date Card -BI Date 82 Date MECHANICAL (Permit) OK except N's 31. A.C. Ducts; Insulation & Support orrections from Previous Inspections 84. est -Meters agged; Gas -Electric 85. nected-C/O to Grade -HD Approval 32. Vent Fan; Exhaust above Insulation 86. ertificate-Other Certificates 33. Condensate Drain & Overflow; Size & Grade gS -i!/Uf (.� / �tr,�cf T 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet f) Ld�� 35. Attic Access & Platform if Furnace in Attic Card -BI Card -BI Date Card -BI Date Date Card -BI Date ar Date Card -BI Date rd -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING X(Plans) OK except q's Comments at Final: Proper Material & Anchors Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound *71 38. Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) 40: Fire Stops; Furred Ceilings -Stairs -Chases -Tub Bader & Beam -Size & Bearing Hangers -Post Caps -Anchors -Connectors (c )Q5y. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthnq.-Ring. J 4. Fireplace Ties or Type A Flue -Fireplace Throat _ 4S. -Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles ,IL Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions .,47. Garage Fire Protection Framing (NOTE: An entry must be made each time you visit jobsite) JCOUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS P RMIT N 7 County Center Drive - Oroville/ California 95965 - Telephone 916/534-4541 • APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 2 - 0 - 7- Q 2 ZONIN �Z BUILDING PERMIT O ER '0.6 B Y � e,4 Y PSoi(/ ELP. EPHON T .5-C✓ F�p9�-�z sib SO. FT. OCC. BUILDING ATION _ / O D . A/pR� SSOWY �/G�r//Q�-oI�`��l(Q/ O9`/Ey�/Ir /" CONTRACTOR'S TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation Is sp.ov Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ p0 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 0 0 $ ARCHITECT ORPenalty ENGINEER'S MAILING ADDRESS Permit fee ; -00 BUILD I; G ADDRESS U1q-12_ 1>1NE belle OAF PLUMBING PERMIT Filing Fee 10.00 Bw-&D AVC4Each D ' Trap 2.00 Repair drainage or vent piping 5.00 (suG,�2 P/N E STOIC 5E/?0 Ci?�(& Water piping LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5,00 Gas piping system 1 - 5 outlets USE OF STRUCTUREBuilding SF ElDuplex❑ Mobilehome❑ Other 8 �Alxoek SPECIFY sewer Lawn sprinkler system 5.00 TYPE OF WORK New ❑ Addition ❑ emodeI L`f Utilities[I Installation Other ❑ Describe work: leEIA15779-L4- /t/C-fit/ 1t9e/O,_ PA971770 // /�� p %Vs% / %i- [`�� � � G4�3S ♦ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 600V OR LESS100 AMP OR LESS Main service 5.00 Main service EA. ADD'L 100 AMP 2,50 NEW CONST. DWELLING OCCUP.y\ OR ADDNS. ACC. BLDGS. 20sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check One): ❑ I am licensed under provisions of Chapt.9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I,, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR .Ou LET 2,50 ea NON•RES'D BRA CH CIRC TS NEW •CONSTR /SINGLE OUTLET CIR. POWER APPARATUS 6) NONRESID. \ ao@@1 Ex, Occup OUTLETS OR FIXTURES BAL@1 Ot IXED APPLNS, OR EX. Occup.�OUTLETS (RESID,) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ , Q Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee S Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. %�/" Date —Z� -- Signature of pplicant -• OWnerR Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE occ�P. GROUP .rL _P' of CONST. 1PARCELI PD_ V7 15911E V/ I This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRE R OF PUBLIC By PER10 EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date.��f���� Receipt No. T 73A?, WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT OWNER t sko& OVK�ZEi�► 'q►V�1L�1 � A. P. Page 1 Permit # #_�2-2� A • RAL Eoaf Zoning requirements (sideyards par ing, special Condit ons). Valuation. Signature by Improvements Complete plot See previous R.C.E. or Architect (if required). Calculations. and drainage -- Land Dev.,DPW; City of Chico; City of Biggs. plan with dimensions, easements, other buildings and other pertinent data. permits and plans in file for expired permits fou , etc. cmmf* Mars -db TAV%&0 B. OCCUPANCY REQUIREMENTS 1. Building use 2. Occupancy Class _ J 3. Building floor area 4. Total allowable floor area Basic allowable floor area Basis for increase JVALI Type of Co tr 0 sq.ft. Occupant Load sq.ft. � '� sq.ft. •�'� Additions, alterations, and repairs exceeding 50% (Sec. 104). C%!?% "compliance with occupancy group requirements (Chapters 5-13). cupancy separations. (Sec. 503). k'8�Area separations (Sec. 505). -Area due to location on property (Sec. 504).'�QtAt1 �ff� 1 Maximum height requirements (Sec. 507). �sV1ew WtT11 �m 11! Attic separations (Sec. 3025). 1� entilation and special hazards requirements (Chapters 6-13). 13! Fire extinguishing systems ( s stems 09 & Mechanical code requirement -/fire spri"n7remr system - Chapter 0). Health Dept. Plan Review - a) ur1= Ac (b) Co ercia Smoke detection system. e�- a'�a _ Z,- a- 1.. Fire Dept. Plan Review and/or Fire Marshal Plan Approval. Electrical Code Requirements (Pools or hazardous occ.) (Art. 680 & 500's). C. TYPES OF CONSTRUCTION REQUIREMENTS Y Fire retardant roof coverings (Sec. Parapet walls (Sec. 1709). Toilet room floors and walls (Sec. Physically handicapped (Sec. 1711 6 5e Guardrails (Sec. 1716). 1704) . E'K%"0k 1711) . CM Table 33A). K. Detailed types of construction requirements (Chapters 17-22). J/ Proper roof pitch for roof covering (Chapter 32). i;."'Attic access and ventilation (Sec. 3205). 9,l oof drainage '(Sec. 3207) . lv. Skylights (Chapters 34 & 52). 1 Stages and platforms (Chapter 39). Interior wall and ceiling finish (Chapter 42). 13#*.' Fire resistive requirements (Chapter 43). 1K. Wall and ceiling coverings (Chapter 47). 1V. Glass and glazing (Chapter 54). Human Impact (Sec. 5406). 16/'Building Materials - Check: Grade, Species, Allowable Stresses, Ext. or Int. -- Example: (Glu -lam Beams w/ certif. 24F ext.grade). .: Page 2. 'MULTIPLE FAMILY AND COMMERCIAL'PLAN CHECKING GUIDE (continued) D. UAIRS. EXITS AND OCCUPANT LOADS tGeneral Exit Requirements (Sec. 3301) (Post occ. load, etc`.). ber of exits, width and locations (Sec. 3302). rs (Sec. 3303). ridors and exterior exit balconies (Sec. 3304). irways, rise & run, width, winders, and construction (Sec. 3305). 6. Horizontal exit (Sec. 3307). 7 /� Exit and smokeproof enclosures (Sec. 3308.'& 3309). 8i( xit signs and illumination (Sec. 3312). 9 A'sles & seating (Sec. 3313).. l0�its for occupancy groups A-E (Sec. 3315-3319). E. ENGINEERING REGULATIONS, DESIGN, QUALITY, MATERIALS, AND DETAILED REQUIREMENTS Complete plans sufficient to show how building is proposed to be constructed and to verify conformance with Chapters 23-29. Plans must include plot plan, floor plan, foundation plan, elevations, and complete structural details. 'W%%L 164. V- _ - VAR -2—.Energy design, calcs, and necessary details (Sta e 1 w).�►Ti► -3—. Veneer (Chapter 30) . Chimneys and fireplaces (Chapter 37). Engineered plans if required. Plastics (Chapter 52). Excavation and grading (Chapter 70). X.' Continuous or Special Inspection (Sec. 305). i // Factory or other certification. 91 Soils or compaction data. 10�. Noise regulations. 1I Footing reinf. Min. Two #4 bars (cont.). l . Engineering Calc(s) should include: (a) Roof - Ceiling. (b) Floor - Ceiling. (c) Foundation. (d) Walls -- Large openings? (consider lateral). (e) Lateral:' 1. Roof Diaphram. 2. Shear Walls. 3.• Anchorage & Tie -downs. 4. Connections thru-out. (f) Retaining Walls. 287-81 Roger Kohler Permit #1104-84 OFFICE COPY Address pzAr—> - GAS Meter By Date. E L E C T RJC�--� Meter By Date COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - OroviIIe, California X5965 - Telephone 916/534-4541 APPLICATIDN'AND PERMIT PERMIT NO. l ASSESSOR PARCEL NUMBER IL C 7" _ Z u ZONING �� I, BUILDING PERMIT OWNER _ 1 C, t f. TELEPHONE SQ. FT. OCC, BUILDING VALUATION OWNER'S MAILING ADDRESS /_ -i r _� E G C 1'rr z4. I CONTRACTOR'S NAME fr'•r j, :TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER✓(NLS.+ UNKNOWN Total Valuation $ Filing Fee $ 10.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILDING ADDRESS PLUMBING PERMIT FiIIng Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 �_'[ r ('✓ .� Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE .t_ - I SF ElDuplex ❑ Mobi lehome ❑ Other L f ' =' '�' SPECIFY Building sewer 5.00 Mobile Home S G W 10.00 Be TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Uti Iities ❑ Installation ❑ Other 0• Describe work: r, r( r f L Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 600V OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.& OR ADDNS. ACC. BLDGS. 2I/Z0sgft CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR (MULTI -OUTLET 2,50 ea NON -REBID BRANCH CIRCUITS) NEW CONSTR. I POWER APPARATUS &' NON-RESID,/ %SINGLE OUTLET CIR. Ex. Occup\OUTLETS OR FIXTURES BA 0300 FIXED APPLNS. OR Ex. OCCUp. OUTLETS (RESID.) EA.1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. X Date Signature of Applicant — Owner ❑ Contractor ❑ Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ 1?, CL. OCCUP. GROUP I TYPE OF CONST. PARCEL PD I HD I ISSUE 1/ This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT 'COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 APPLICATION -AND-PERMIT . � PERMIT NO ASSESSOR P CEL NUMBER �0—ZQ — Z ZONING BUILDING PERMIT W OE i�/G T LEPHONE SQ. FT. OCC. BUILDING VAL TIO U' OWWMA13� ADDRESS �� ^�' lj`f / CONTRACTOR'S N(��A(MTJE oVV/V EPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LEND UNKNOWN Total Valuation is Filing Fee $ 0.00 LENDER'S MAILING ADDRESS Permit Fee $ ARCHITECT OR ENGINEE 71 LICENSE NO. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILD&eDRE ^�` PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Solar Water Heater 20.00 L -NAME Water piping 5.00 LOT NO. SUBDIVISION PARCEL MAP Each qas waterheater or vent 5,00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE ' SF ❑ Duplex ❑ Mobi lehome ❑ Other 17�i(l P�E �l-S /l/��� SPECIFY Building sewer 5.00 Mobile Home S G W 10-00ea TYPE OF WORK New Q Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other Describe work: C`'L�UI�CA� Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 1000V OR AMP ORLESS10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.& OR ADDNS. ACC. BLDGS. 2/20sgit CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one): ❑ I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CON5T NON•RESID R. BRANCH CIRCTITS 2.50 ea (� NEW CONSTR POWER APPARATUS 9 NON-RESID. SINGLE OUTLET CIR. / Ex. Occu 20050e P�ourLErs OR FIXTURES BAL®30 FIXED APPLNS. OR Ex. OCCUp. OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3,00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify a keep harmless the County of Butte against all liab' ' ' judgmen d expenses which may in any way accrue again aid y i n e e of the granting of this permit. X Date ° Sign tura of Applicant — Owner Contractor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construct-AD=L-CTOROF ion of structures over 33 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ OCCUP. GROUP TYPE OF CONST. JPARC.ELJ PD ND IS E This permit is hereby, issued under sion f the Butte County Code and/or wor di ted above for which PUBLIC B PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been aid. p WORKS Date 2�/7—ci -1 Receipt No. /O l3z, WHITE-D.P.W.. YELLOW -ASSESSOR. PINK -INSPECTOR. GOLDENROD -APPLICANT