Loading...
HomeMy WebLinkAbout062-650-003062-65-0-003 98-15Oa 062-6502003 PERMITN98-0850 EDWARD J AND HILDA M MLECZKO _ MLEEZKO, Judy & Ed 100 Silverado Trail, Oroville /00 Silverado Trail, Berry Creek (AG EXEMPT tractor sta.hav) Cont: Steve Orsillo i New Single Family� 14*71K .26 • 4 5 r BUILDING DIVISION COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE: (530) 538-7541 AGRICULTURAL BUILDING EXEMPTION PERMIT PERMIT NO. Agricultural building is defined as follows: Agricultural building is a structure designed and constructed to house farm implements, hay, grain, poultry, livestock, or other horticultural products. This structure shall not be a place of human habitation or a place of employment where agricultural products are processed, treated, or packaged, nor shall it be a place used by the public. ASSESSOR PARCEL NO. O ZONING 5� OWNEREd.)Q J d , 1 j Z f j O T� PHONE NO. OWNER'S A DRES ' 1DssoM 1�k. 3am Tale Sia LOCATION OF BU LD KIQ USE OF BUILDING a r SIZE OF STRUCTURE! 2 �j�/� ."7 ' X J 6 _ � SQ. FT. TYPE OF CONSTRUCTjON: WOOD FRAME -7STEEL CONCRETE OTHER (Specity) TYPE OF SIDI a ROOF COVERING a� FLOO TYPE raves ESTIMAZ COS T'lOF CONSTRUCTION $ lJ AG Buildings shall comply with the minimum front, side, and rear yard setback requirements of the applicable County Ordinances as follows: �- r - I - i - FRONT �J /j"'`� SIDES 20 4M4'L' REAR AG Buildings shall be a minimum of five (5) feet from any septic tank or leach fields. AG Buildings less than 1000 sq. ft. in floor area shall be located a minimum of 6 feet from a residence, 10 feet from a mobilehome, and 23 feet from a commercial building. AG Buildings greater than 1000 sq. ft. in floor area shall be located a minimum of 23 feet from a residence and a mobilehome, and 40 feet from a commercial building. AG Buildings must comply with Flood Zone requirements. Finish floor elevation must be at or above elevation USGS Datum. I declare under penalty of perjury that the building will be used as stated above and the purposed use confirms with thl AG Building definition. If any change in use or occupancy of the building is made, I will contact the Building Division ani obtain any necessary permits, inspections, and approvals to comply with the requirements in effec at that time and befor occupancy. Date Signature of Owner 4&t::5aaJ I -M Permit Fe - $60.00 The above described AG Building is exempt Yom a buil ing per it. FLVO I PARC P. ROP04G ISSU Receipt No. AS 7 z 9 SS Manager Building Divisi By Date 2 3 / Ps White — DPW, Yellow — Assessor, Pink — B. I., Goldenrod - Applicant II RESIDENTIAL 062-650-003, PERMIT#98-0850 'PERMIT NC-MLEEZKO, Judy & Ed 11 /(Y)Silverado Trail, Berry Creek PERMIT EX Cont: Steve Orsillo New Single Family %OWNER -CONTR. ASSESSOR PARCEL .LOCATION 44 CHECKED BY X SRA FLOOD CERTIFICATE REQ. _ FIRE SPRINKLERS REQ. — SPECIAL INSPECTION ITEMS VERIFY Temp. Power 0 . OFFICE COPY Address Called PGI Temp. Elec. Sel, GAS Called PG8 ELECTRIC DM17*W Meter By Temp. Gas Service Called PG&E JOB FINALED (Date) A120A,:� Signature V=OK , 0 = Not OK Not ' = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 1. Zoning Requirements - Setbacks - Easements 2. Footings; Soils-Size-DepthSpacing-Connectors-Steel 2. Soils; Special MH Support Sketch 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Wood Awn.; Posts-Beams-Rttrs.-Connectors Shthg: Rfg.-Bracing 4. Water, Location -Test -Easement Needed (Sketch) 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 5. Electricity; L.ocaton-Clearances-Gmd-/ /Amp -Concrete ----- 6. Carports; Windows -Doors 6. Gas; Location -Test -Wrap; / 112tt / /Nat or/ /'L°tt./ /LPG 7. Electric 7. Well Clearance & Disconnect 8. Frmg.; Sils-AnchorsStuds-Rttrs-Trusses 8. Utility Clearance 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s Card B-1 Date Card B-1 1. Zoning Requirements -Setbacks Easements Card B-1 Date Card B-1 2. Footings; Size -Spacing -Marriage Line POOLS (Plans) OK except #'s 3. Gas; MH Test -Demand Valve -Connector 1: Setbacks -Easements 4. Electricity; MH Test -Crossovers -Breakers -Clearances 2. Soils; Compaction -Structure Stability 5. Drain; MH Test -Fall -Flex Connector 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 6. Water; MH Test -Regulator -Connector 4. Eke.; Receptacles and Lighting, Distance-GFI 7. Water and Sewer Connected -C/O to Grade -HD Approval 5. Elec.; Pool Lighting; 15 Volts-GFI 8. Gas and Electricity Tagged 6. Elec.;'Enclosures; Conduit Entries -Terminals -Listed 9. Tie Downs -Type -Installation Cert. 7. Elec.; Bonding; Metal w/5 -Circulating Equip. -Heater 10. Exits; Insp.-Sketch 8. Elec.; Grounding; Equip. w/5 Circulating Equip. -Pool L.ghtq. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 11. Cert of Occupancy 9. Health Department Approval 12. Permanent Foundation Only: License Decal 10. Plumb.; Cir. Test -Water Supply Test Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 4 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils-Size-DepthSpacing-Connectors-Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rttrs.-Connectors Shthg: Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sils-AnchorsStuds-Rttrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1: Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Eke.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.;'Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5 -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5 Circulating Equip. -Pool L.ghtq. Boxes-Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card 8-1 V = No OK RESIDENTIAL - = Not Applicable = Not Ready Date UNDERFLOOR (Plans) OK except #'s ningSetbacks-Easments-FloodSlope F ., Main; Soils-Elec. Gmd.- i Ftg. Depth 3 Ftg. Garage; Soils-Steel-Elec. Gmd/ P Ftg. Depth 4. Ftg. Porches &Decks; Soils -Steel-/ N Ftg. Depth temwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 1 ienums & Ducts; Clearance -Material -Support -Ins. r14 rdersSills-Anchor Bolts -Joists Vents-Crippies 4A& -Access & Ventilation 16. Insulation Date 4,42A, eCard B-1 Date Card B-1 Date .7_4,4 Card B-1 Date Card B-1 Date LUMBING (Permit) OK except #'s er Htr.; Vent- ss -Combustion Air Baffle W r Pipe; T & hor-Na' Protectio o it 20. Shower Pan; Test, First Floor -Tub Access - e & Shower, Second Floor -Tub Access Gas Pipe; Sixe & Anchors Date i/g Card B-1 IZ,�; Date Card B-1 Date _61e6 Card B-1 (4!�F Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 23. F' re & Transformer Clearance -Ins. Protection EI Receptacles Spacing -Lights & Switches at Doors S}ze Boivas & No. of Conductors Stapled . R9w= Installed Close to Edge of Studs & C.J. E . Ground made up w/Mech Fastners-Bond Gas & Water 2 Appliance Circuts in Kitchen & Conductor Size GFI 29. SVWeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI Range Circ. g0or AI -Oven Circ. /%S / g Cu r AI 1ted Neutral 0 Yes p No Service -Riser Conductors & Ground -Main Disconect 32. Equip. Clearances Panels-Motors-Mech. Epuip. 33. C ,We, Closet Light -Shower Light -Spa Light Smoke Detector Date JS,91 Card B-1 40. Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 35. A .Ducts Insulation & Support ent Fan, Exhaust above insulation 37 ondensate Drg Dr ' & Overflow, Si�e Grade 38 .mance-V A s -Com r -Ret. r Vent 11 Autlet if Furnace in Attic Date Card B-1 Date Card B-1 Date C B-1 Date Card B-1 Date RAMMING (Plans) OK except #'s it oyer Materials & Anchors over Girders & Floor r p in Walls (rat proof) 1��!toBtops, Furred Ceilings -Stair � r eaders & Beams -Size & Bearing (Single & Duplex) C�l�q.. Joist-RfV. Ties-Purlin-roff Brac: TrW-SfyNi ng—� fireplace Ties or Type A Flue -Fireplace Throat cleave L%_ ss; Size & Romex Protection -Draft Stop -Ins. Baffles drJn .Windows or Exiting Doors -Sill Hgt. & Dimensions arage Fire Protection Framing Openings c Garage 3rd Protection vywooa on moot uvemang-Amc vents -Matter outriggers 56. Siding -Nailing Veneer k'57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access Glozing Area -Glass tection- lights -Plastic Oe"Shear Walls; K"' g -B 60. Brace Interior / Exterior Wall Panels _1. nsujoon-Walls-Ceilings FA,oMTiltrafion-Walls-Windows Date Card B-1 Date Card B-1,48 Date _ 47 Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 12 Ext Steps -Door & Sidelight Protection -Landings S e Detector Fumace; Vents -Clearance -Comb, Air-Conector- In Garage; Above Floor-Ducts-Mech. Protection .�edioom Exiling ,;�.FI. & Bath Fixtures & Tub Access -Spa 68' 9e. Trim & Subpanel, Breaker Sizes & Labels fairs & Rails Z,replace or Stove, Clearance -Hearth Fes. Outlets at Wood Panel, Int. & Ext. 7p! it. Fixt. & Appliance; Ground. -Air Gap -Cooking Clearance E . Outlets & Recepticales at Kit. Counter / JWGaraae Fire Door; Swing -Landing -Closure W. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. )f Garage; Above Floor -Meth. Protection Elec. & Mech. Equip. Listed for Location lec. tacles in Garage G.F.I. -Romex Protection JCJ-gullation- in Attic and rails & Deck Construction -Post Caps Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor f1 Yes I i V/following Instld./Drive2les Q No/Walks2les Q No/Planters 0 Yesoo Stucco Brown -Finish V A.C. Unit Disconnect, Electrical -Plumbing 10 -Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings er Well, Disconnect, Electrical, Plumbing tenor Elec. Trim, G.F.I. Receptacle -Underground W. Ventilation Throught House 89. lass Protection o ections from Pre ' us Inspections as Test -Meters gged, Gas -Electric er & Sewer Connected -C/O to Grade -HD Approval Energy Compliance Certificate -Other Certificates Date Card B-1 Date Card B-1 Dat Card B ,Z,,' Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION .7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 nom, �PERM iT ruo• (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER062-650-003 ' • ZONING 11.13 BUILDING PERMIT OWNER MLECZKO, JUDY AND ED TELEPHONE SO. FT. OCC. BUILDING VALVA ON OWNERS MAILING ADDRESS 5742 LILAC BLOSSOM LANE, SAN JOSE 95124 7 946 CONTRACTOR'S NAME STEVE ORSILLO TELFPfg 532-11 77FF 1Mg1X CONTRACTORS MAIuNG AD "296 OLIVE HWY. , OROVILLE 9596!6%, 4L ' 890 CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. -Filing Fee 20.00 Permit Fee $ 657.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS /00 SILVERADO TRAIL, BERRY CREEK Energy Plan Checking Fee $ 23.00 $ PERMIT FEE $ , LAT NO 3 sftt% Alb SUBDIVISION PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF 3J Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 63.00 Solar or heat pump water heater 23.00 Water piping 15.00 15.00 Each as water heater or vent 15.00 15.00 TYPE OF WORK New 1K Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 2 BEDROOM Gas piping system 1 - 5 outlets 15.001 15.00 Building sewer 15.00 15.00 Mobile Home S G W @20.00 PERMIT FEE $ 143.00 ELECTRICAL PERMIT Filing Fee 20.00 Main Service ZOOA V.LESS 23.00 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter • 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is i II force and effect. ���� , / License Class Lic. No. tl� OWNER BUILDER DECLARATION hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. a workers�compefLsa� in anc�e Ge er and,{�olicx number are: Carrier ((��jj0 LCIEA-) 11 �N � Policy Number We- - : Q? S� 0 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall- not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X ____ ate _� 5�- Signature of Applicant - ❑ Owner ❑ Contractor XAgent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. (p • c. only 237061/996.85 Main Service 200A To I000A 46.00NEW CONST. DWELLING OCCUP. SO 88.35 OR ADONS. ( 6 ACC. BLAS. S 5 3.50F`Q NEW CONST. MULTI -OUTLET NON-RESID. 4NC cl 97.50 POWER APPARATUS a SINGLE CIS. R FIXTUTLETRES Ex. Occup. OUTLET OR FocruREs BAS p':5o UNII Ex. Occup.OUTIers A o.1 Ek 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 131.35 MECHANICAL PERMIT Filing Fee 20.00 Heating 15.00 Cooling 15.00 Hood 6.50 6.50 Ventilation PERMIT FEE $ 96-50 Mobile Home Installation Fee $ Energy Inspection Fee $• 00 oc CONST. TV 7NTOTAL FEE $ 1,503.90 HAZ. - D. F IM k FL.O D F p `,�CEL �Q H%1 ISS Ug This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date 6/3/98 PERMIT EXPIRES ON 6/3/99 gra Receipt No. 2367 �3-407 Q5// WHITE-D.D.S.-B.D. CANAWASSES�SOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 Ctyen Cter Drive - Oroville, California 95965 - Telephone (916) 538-7541 ,ERMIT NO. (Rev. 12/96) IV ounAPPLICATION AND PERMIT ASSESSOR PARCE), NUMBER 1© - ®D3 ` HCl) 20NIN0 BUILDING PERMIT owNEq u TELEPHONE SO. FT, OCC. BUILDING VALUATION OWNERSIU ADDRESS J 11 e ��� J 01 "I'V42 CONI OR'S NAME ve ©/ S' �7 TELEPHONE I CONT)M(1.T�r0G ADD SS f , / _/?��CIT J `� CONSTRUCTION LENDER LENDER'SMAIUNO ADDRESS Fireplace S' Total Valuation $ Q ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 1/ S! Q ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ �, Q BUILDING ADDRESS i` veLrao Too -,Energy Plan Checking Fee $ E''r r LLF $ PERMIT FEE S f Q IDT NO. SUED LSp SHAME c V Cil` U � P E � � PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF/kfoo�Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00'3L Solar or heat pump water heater 23.00 Water piping 15.00 Each as water heater or vent 15.00 tl , TYPE OF WORK New ® Addition ❑ Remodel ❑ Utilities 13 Installation O Other ❑ ADescrrib`e Work: f� Gas piping stem 1 - 5 outlets 15.00 �.�OD Buildingsewer 15.00 Mobile Home I S G W @20.00 PERMIT FEE S c ELECTRICAL PERMIT Fling Fee 20.00 Main Service 800V OR LE 2o0A OR lES3 23.00 Z, LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is irMygorce and effect. O , / License Class LIC. NO. �[-- OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: 0 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers�yorr�pe sation in ance carrier and policy number are: Carrier Z� I?_ Main Service TOGA TO IOOOA 46,00 NEW CONST. DWELLING OCCUP. OR ADONS. ( 8 ACC. BLDS. 3.50,7SO; I,Gµq ,p MULTI -OUTLET TS @7,50 POWER APPARATUS 8 SINGLE OUTLET CII, Ex. Occup. OUTLET OR FIXTURES BAS 0':� Ex. Occup.ouT��RESIO.DEA 5.00 Temporary Service 23.00 ^— Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating JSt-9-0- Cooling JT, Q Hood 6.50 ( , Ventilation +-- PERMIT FEE S ,S Policy Number — 3,y a __6 ) (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 111 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. I X ______ a eJms_ Signature of Applicant - ❑ Owner ❑ Contractor Agent An OSHA permit is required for excavations over'0" de p a dem lition or construction of structures over 3 stories in height. C 3966 Mobile Home Installation Fee $ Energy Inspectin Fee $ c TOTAL FEE $ `SQ� gQ HAz. D. FEES IMP ,LOO CX PAR- COY PD v HD uE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date Dale Receipt No. '" C 1 WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK-INSPE 22R GOLDEN ROD -APPLICANT COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: 1'( CPASSESSOR PARCEL NUMBER: Proposed Building Ude: Building Inspector: Date: At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: Date Received By ❑ 1. All items have been submitted -------------------------------------------------------------------------------------- 02. Plot plans, 3/4 sets, signed by the preparer of plans. ---------------------------------------------------- 03. Complete plans, 3/4 sets, signed by the preparer of plans. --------------------------------------------- 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! --------- ❑ 6. Energy Design Compliance and supporting documentation. ------------------------------------------- ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. ------------------------------------------------ ❑ 8. Hazardous Material Form.--------------------------------------------------------------------------------- 9. Manufactured Home data and installation instructions including Tie Down Specifications.------------------ 0. Fees of $ l------------------------------------------------------------------------------------- .� Impact fees as shown on the attached schedule. -- ------------ ------ --- - ---- Cahfornia Department of Forestry plan appro aUf -- - -------------------------------- 1113. Flood elevation certificate.--------------------------------------------------------- I ------------------------------ JIW4. Sanitation and plot plan approval s Health Department. ------------------------------------------- _ 'Y ❑ 15. City of Chico plumbing permit. ----- ----------------------------------------------------------------------------- ❑ 16. Plot plan and business license approval from the City of Biggs. ❑ 17. Planning approval for (A) Use (B) Parking: ❑X0nlac'Lnd Development about❑Improvements,❑Parcel. ---------------- ncroachment Permit for driveway (construction approval prior to occupancy). --------------------• 020. Pre -inspection for required. Request to Building Inspector on ❑21. Contractor's license information. (Number, Name Style, Classification). ---------------------- =------------- ❑22. Workers' Compensation carrier and policy number. ----------------------------------------------------------- ❑23. Owner -Builder Verification (Given to owner ❑, Mailed to owner EI) - -------------------------------------- ❑ 24. Letter of signature authorization. ------------------------------------------------------------------------------- U / "�5 . Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- 026. Letter of intent on building use. ----------------------------------------------------------------------------------- ❑27. Manufactured Home utility clearance. --------------------------------------------------------------------------- ❑28. Existing violations and/or expired permits.---------------------------------------------------------------------- ❑29. 043 A, ❑Grant Deed, ❑ M.H. Title, ❑ Check to H.C.D $ er: — Sit oy G/GI .3oD o./_ 6V 7,�"4e 6>/G0,Z- �d��' `� ' �'"i/�2eG��u�s When you issue the permit, process as follows ail to owner, ❑ ail to co actor. /�� r „z . �y Telephone 7 `J� and hold for pickup at 1^© V , office. ❑ Deliver with inspector. Applicant: w Date: -s-sr- Copy Copy of Haz-Mat form sent ❑ Health Department, ❑ Fire Department, ❑ Air Pollution Date: By: Copy of plans sent ❑ Health Department, ❑ Fire Department, ❑ Other: Date: By: 1. Index permit application for the above items numbered: ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by ❑ phone, ❑ mail, ❑ Building Division counter, by Date: Contracto Owner, was advised of the above required data byWhone, ❑ mail, ❑ Building Division counter, by Date: < ---7.1 -52 Contractor, designer, owner, was advised of the above required data by phone, ❑ mail, ❑ Building Division counter, by Date: Contractor, designer, owner, advised of the above data ❑ phone, ❑ mail, ❑ Building D'vision counter, by Date: Plans reviewed by: Date: Plans approved`by: �-- Date: Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. 4 (Date) r TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Z-�J61G,oA Owner Location Plan Approved�ree sposal Water Supply: Public Clearance for welling. Other z Hold final f&: Final cleara'h' q'. K. fo NOTE: �/ Environmental Health Spe •. E.H. USE EN;— Plot Plan Attached Sent Plan Attached � Sent to B.p../ U .SsQ QCT AP# Private Well L� A- Date COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 TELEPHONE (916) 538-7541 SCHEDULE OF FEES DUE OWNER --- A.. P.* # PROPOSED BUILDING USE /�%�• J �- DATE REC # DATE REC 1. BUILDING PERMIT FEES Q' /f -- Q Balance Due ................ -- Additional Fees Due ........... $ -- Additional Fees Due ........... $ -- Revised Plan Checking Fee ....... $ 2. SCHOOL DISTRICT FEES Q/"C7 (paid at District Office) a% d . 3. SHERIFF FEES (paid at Building Division) ���. OD ��� Residential ........ � x $360.00 = $ 6 Units Commercial (sq.ft.)... x $0.03 = $ 1 Sq. Ft. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit) . x = $ #Units Amt. Commercial (sq.ft.) x =$ Sq.Ft. Amt. 5. RECREATION DISTRICT FEES (paid at District Office) 6. THERMALITO DRAINAGE DISTRICT FEES r$4.00 (paid at Building Division)A FRE INSPECTION AND PLAN CHECK $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. APPLICANT DATE �7 Original -Owner Copy -Building Div. (Rev. 12/96) And when recorded mail to: Building Division #7 County Center Drive Oroville, Ca. 95965 1'398-01023003 Recorded Official Records County Of Butte CANDACE J. GRUBBS Recorder REC FEE 10.00 CONFORM .00 I Fay 02:36PM 03 -Jun -1998 I Page 1 of 2 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code requires this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from'the use of agricultural chemicals, including. but not limited to herbicides. pesticides, and fertilizers.,,and from the pursuit of agricultural operations including, but not limited to cultivation. plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise. and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal. necessary farm operations. All that real property situate in the County of Butte, State of California. described as follows: s, t , -- P�k,\,8 S6� Date:—J-- �' �� PROPERTY OWNERS: 2- State of California ) Countv of Santa Clara ) On On 5/4/98 before me, Belen B Clark personally appeared Edward J Mleczko and Hilda M Mleczko personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument,, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my and and official seal. BE! EN B. CLARK coMMissioN #1102968 o Notary Public - C ie Signature Seal. _ � SANTA CLARA COUNTY v My Commission Expires JLINE 27; 2000 •,. P. # O 66-0, ~ 60 3 NOTE TO RECORDER: DO 1 �' RECORD THIS SIDE ' Instructions for recording Agricultural Statement of Acknowledgement: 1. Insert the legal description of the property in the space provided on the other side of this form. The legal description is the narrative description of the property - which will be on your deed. If you don't have access to the deed, the Recorders Office can provide this information. ( The description may be handwritten or typed in the space provided or attached on a separate sheet if more space is required). 2. Property owners must sign in the presence of a Notary Public and have the form notarized. 3. Make a copy of the form and then take the original and copy to the Recorder's Office at 25 County Center Drive, Oroville (the Administration Center building). The Recorder will record both the original and copy. They will keep the original and return the copy to you. Just bring the copy back to the Building Division at 7 County Center Drive. RECORDER'S FEES: $6.00 - 1st. Page $3.00 - Each Additional Page RECORDER'S OFFICE HOURS: 9:00a.m. - 3:00p.m. (Monday - Thursday). OVER 89-37031 ORDER NO. BU -108020-3 DESCRIPTION: ALL THAT CERTAIN REAL PROPERTY SITUATE IN THE STATE OF CALIFORNIA, COUNTY OF BUTTE, DESCRIBED AS FOLLOWS: IAT 3, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "SILVERADO SUBDIVISION", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON OCTOBER 28, 1988, IN BOOK 112 OF MAPS, AT PAGE(S) 31 THRU 35. RESERVING THEREFROM A NON—EXCLUSIVE EASEMENT FOR ROAD AND PUBLIC UTILITY PURPOSES OVER THAT PORTION LYING WITHIN SILVERADO DRIVE. PARCEL II• A NON—EXCLUSIVE EF.SEMENT FOR ROAD AND PUBLIC UTILITIES EASEMENTS OVER THOSE CERTAIN RCADS'SHOWN AS CHEYENNE COURT, AND SILVERADO DRIVE AS SHOWN ON THAT CERTAIN MAP ENTITLED, I'SILVERADO SUBDIVISION", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON OCTOBER 28, 1988, IN BOOK 112 OF MAPS, AT PAGE(S) 31 THRU 35. EXCEPTING THEREFROM ALL THAT PORTION LYING WITHIN THE BOUNDS OF PARCEL I, DESCRIBED HEREIN. STATE OF CALWOMA ty of BUTTE ass. 1� On this 7 day of Slt %�/ i4 H�ISiY.0 , 19 �, before tre, the ersigned, a tary Public in and for the State Ot CALIFORNIA . duly ccmnissioned and wworn, personally appeared HENRY T. RANGE. JR. . personally known to rte 70=VmVrmC<tn ate:f� cinettlmds:o!!c eaCletacCatx::: Rvldtncnl, to be the individual described in and who executed the foregoing intstnanent for HIN self and as attorney in `act of CYNYHIA A. RIIN. also therein described, and acknowledged to me that he si4ned and scaled the sane as al voluntary act and deed and as the free and voluntary act and deed of the said—_Mr-e—vo , es and purposes therein menticned, and on oath statedf at y autlorizing the execution of this instrtanent has not be! �ITItI+,�QuyLFis na+ living. WME1 seal rete affixed the day and year in this certificate above wrltDANIEL F. HUNT ,� r•,:; , .� �. • MO'ARV PUULIGCALIf•ORNIA ■ Signature w ;y y „��:`;� Uutte CuuMy ■ �,�i A) • My Co AMISSIon EXPLM 001. 1, IOBO • (This area for official notarial;14A)mrr WON ■■■■■■■�■r■■rrrr� END OF DOCUMENT :;:xl3Sd-.:x:::,+�Y�s1�•is:i��"�'u:P.ei3�E Et _.,... .,__.�'._. :�<):si`r.�.�k;'.:._.�,e.±<::�v..:'�'ar�::'""iti.%M.i';�.,i,:.�S.�!:�"�.i;alf�"ti�``'s'?+il�;fxc. �i.•x:�vicr'J�'rh 4:�rif'�. �w'_iii•�A _. .t'�T.rkid.e: £f;'� �.i"b`^^'ly^h�y.�'' �°'`^�iA"'t��'�";'F�. �i �tr^�.w(K` r(�]'�"�r%r'��t'�'�x�s�7�`Pi'�STi�...,"T `",Fr,�.�"+-•�"Tr' 1+"r"1.,�R}Tf,�+`, ,�.,;;i�G.'.;"i�:.-"y"`.T ^it-...y.rr�.c.. ,, . a BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) a r R School. District . �Q I✓L P1 s n ! ► S "Building Department No. A.P. Number Property Owner /V- pl /Oso - DJurisdiction: City County Property Location/A Subdivision Residential Development No of Living Units Commercial/Industrial Mobile Installation Naw . Lot No, Addition Arirlitinn Building Department Representative lrioor dans revieweD Dy acnooi uistnct versonnell ^ Sq. Footage JQ( 0 ! (Group R) Sq. Footage (Including Exterior Roofed Areas) Date District Identification No. 9 8 O 1 3� - 4 J School District certifies that a. 14 1 Q C a . (Applicant) t)d KC0 (Street Address) (Phone Number) (City) has complied with the requirements of Resolution No. representing /5 square feet. School District Representative (State) (Zip Code) 9,0 by payment of $. IFBi2926 $ ULL MITIGATION - $ u x Date r Paid by Check # �� it/''i �, fj, Remarks: Notice: You may protest the imposition of the fees identified above by -submitting a written protest to the District, in compliance: with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. r If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the. school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls (2/97)dmm N STATE OF CALIFORNIA MINI -MEMO STD 100-8 (REV. 9.70) TO: SUBJECT: &t6 .. ie- D e o DATE (',' --2— q8 s s A G E SIGNED ADDRESS PHONE RETURN TO Q- Z 99 SL R E P L Y SIGNED ADDRESS DATE SEND PARTS 1 AND 3 INTACT - PART 3 WILL BE RETURNED WITH REPLY 85 93594 STATE OF CALIFORNIA MINI -MEMO STD 100-B (REV. 9.70) S S A G E a i TO: SUBJECT: �(-� F Z (✓ DATE -2- SIGNED L ADDRESS PHONE RETURN TO R E P L Y SIGNED I ADDRESS - I DATE C SEND PARTS 1 AND 3 INTACT - PART 3 WILL BE RETURNED WITH REPLY 85 93594 `M ' MIT COUNTY OF BUTTE- DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION County Center Drive - Oroville, California 95965 -Telephone (916) 538-7541 ERMIT NO. N. (Rev. 12/96) APPLICATION AND PERMIT 6W- �i� ASSESsPARC$NL6 ZONING BUILDINGPERMIT o„„NE N T /c b TELEAMO"E SO. FT. OCC. BUILDING VALUATION OWNERS mAiuNdADoAES9 550 n 05e 9r� (,L CONT R s NAMETELEP,+oNe vt' �/ S C CO T 9(1�1LJNG ADO SS CONSTRUCTION LENDER i Fireplace LENDER'S MNUNG ADDRESS ' Total Valuation S ARCHITECT OR ENGINEER LICENSE No. Filing Fee $ 20.00 Permit Fee $ S �, D ARCHITECT OR ENGINEERS MA,UNG ADDRESS Plan Checking Fee S 7_ SUILOLNO ADORESs i v(1(� Q �!^ Energy Plan Checking Fee S i, b PERMIT FEE _ LLT NO. Bu -SO V771IPARCEL PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF uplex ❑ Mobilehome O Other sPEcLFY Each Trap 7.00 63,06 Solar or heat pump water heater 23.00 Water piping 15.00 8,00 Each gas water heater or vent 15.00 TYPE OF WORK New (�`Addition E3 Remodel ❑ Utilities ❑ Installation O Other O Describe Work: Gas piping system 1 - 5 outlets 15.00 Buildingsewer 15.00 Mobile Home I S I G W Q20.00 PERMIT FEE $ ELECTRICAL PERMIT Fling Fee 20.00 OOOV LE Main Service iow oROR LE,sss 23.00 LICENSED CONTRACTOR'S DECLARATION hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is i orce and effect ^ O License Class Lic. No. =,54 oL OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. a workers' �sation inE;Ot c�cQerrier end policy number are: Carrier (G1p[C�¢_IL> �F�c� Policy Number lU — a, $-__ G ) (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) not employ any person in any manner so as to become subject to workers'HAz compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the tabor Code, I shall forthwith comply with those provisions. X t c ate � S Signature of Applicant - ❑ Owner ❑ Contractor Agent An OSHA permit is required for excavations over '0' de a de lition or construction of structures over 3 stories in height. C Main Service 200A TO 1000A 46.00 NEW CONST. OWELLING OCCUP. SO.3 OR ADOS. ( ACC. SWSS. 3.5¢x; , New ►A NoN.RE . 97.50 PowEA APPAMTUS a SwGL� oLmET cR Ex. Occup. OUTLET OR FIXTURES aAL 200I .S0 Ex. Occup. oDs�nE o.�PA 5.00 Temporary Service 23.00 --- Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE t MECHANICAL PERMIT Filing Fee 20.00 Heating S(9 Cooling 4 ; Q Hood 8.50 ( , Ventilation �-- PERMIT FEE S �cs Mobile Home Installation Fee $ Energy Inspection Fee $ G - Oce CONST. TYPE p 5503, !C o FEES IMP FLoo COF PARCELm Ho I ISSUE This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By PERMIT EXPIRES ON the applicable provisions Resolutions to do work been paid. Date (Daro) Receipt No. WHITE-O.O.S -3.0. CANArrIY•ASSESSOR PINK-INSPE7,CR GOLDENROO•APPLICANT I RESIDENTIAL PLAN CHECKING GUIDE SINGLE FAMILY, DUPLEX AND MISCELLANEOUS ONLY OWNER: ,Z2J&/_' 2, A -D BU1LDINGPERM[nNUMBER.ZL ^Q11 �O ;' PLAN CHECKER: A ,:;�, -5:Z,5 A. P. NUMBER: D 50 Zoning requirements: (side yards and number of permitted living units). Valuation. Plans signed by designer. Proper description of work on application. Existing violations on property. Items on data sheet, (Impact Fees, Environmental Health, Developer Fees, etc.). Recorded notice of violation. DT A XT. Complete parcel size and dimensions. Setbacks, side yards, easements, etc. Other buildings or structures. \ Grading, fills and/or drainage. Flood hazard. Special conditions on creation map (Noise, S.R.A., Fire Sprinklers, Water Tender, Trees, etc.). F.A.U. & F.A.S. road setback. Building or utilities across lot lines (Record form). I PIAN: Complete to scale plan with dimensions. Required windows for light and ventilation (Section 1203). Required windows for second exit (Section 310.4). Skylights (Section 2409 dt 2603.7). Glazing in Hazardous Locations (Section 2406). Required room sizes, ceiling heights (Section 310.6). G.F.C.I. in baths, garage, kitchen, wet bar and exterior outlets (N.E.C. 210). Lights, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. Location of water heaters, heating and cooling equipment, other electrical or gas equipment. Garage firewall, door size and closer (Section 302.4). Minimum of one 3'0" exterior door (Section 1004.6). Fireplace and wood stove location, alcoves and clearance. Smoke detectors (Section 310.9.1). .Plumbing fixtures, water closet clearances and shower size. Conventional Construction - Unusually Shaped Buildings (Section 2326.5.4). Standard bracing or engineered design (Section 2326.11.3). Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Elevations and wall construction details complete enough to construct building. Roof construction.details complete enough to construct building. Rafter ties or bearing ridge beam. Fireplace construction details and Calc. if necessary. Garage door and/or porch header sizes. Stud heights. p% -/6>-Z 61­--�/". Adobe soils - special foundation design. Retaining walls requiring design. Special Inspection requirements. Header size. Sheetrock nailing inspection required? July 1996 3.2 V o say details: landings, rise and nm, head clearance, handrails (Section 1006). -rail details (Section 509). or stone veneer (Section 1403). or plaster - weep screeds (Section 2506).roof pitch for roof covering (Section 1501). Roof covering type - (fire hazard). Foam insulation - protection. 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts. Two exits on three - story dwellings (Section 1003). Underfloor access and ventilation (Section 2317.7). Attic access and ventilation (Section 1505). Combustion air for fuel burning appliances - L.P.G. requirements. Noise requirements on duplexes. Energy design Flashing at all exterior openings. C.D.F. responsible area requirements. 401 -,-30dQ Ice er— July 1996 3.3 CA ►,�� 8.5)<«<llZ:;,Ct.a 3� � f =� IV lll`�vje2 2 3� f X� , cel L C V44A4-: H.'"R -2. _.. It l✓� rclUvcJ� '' GJ \ , �c� iN �aCc Sdv- to 6ta-x ov; ca, ruo Fi w - r�-� � vs�.: - : �-C� � ►o �- � g �Cc22 �; � i•�.c� ��s C � :-- . � . V-� ry = Vl-2 ��2��^i I�S �_ %�- �� �" � c�l��c�a ' �� ., ►�•e • �'�ce �c � �c�� N 1 asq �•" j V��C-{ �L4� �I��=t _1-'l\\��C I��O)�1�� -7EA ���'I` J z. i � � I �ftt)� av�:vU f , �. Iv5ok was i -r1 yc .3.570,(£3 t. -t- 1 lo(� LtoX s o �&s �Wdu yv ox): amc� rK .• (SJ�JD---�-cl'�- ��1.�/i?��j't�1-�-t�112CtS�l� ���(l�� , _ _ , - __ , �O WON- e-V�NRWOP- -4 Li sj,�� Z 1 I (; EMT 77 7� Pet .'-.�-n ax (0. ? _�5, 'w'_ j I _- -.._.. ! t C i F I I �, I i � r t V. I. WLSIVTI A- a_ -- _ stir ; f I aQ1 u C7 �� _ -f _-- - --- - - �- - -!- .77 - - -----{-�- -1 ►zI- it VA A6 '--�- CERTIFICATE Or C•OMPLIANC:E: RESIDENTIAL ----------Page -1--_-------CF-IR Pr6j'egt'Title........... CUSTOM HOME Date........ 05/01/98 Project Address.!...... LOT 3-SILVERADO DR. --------------------- BERRY ----------- ------1BERRY CREEK. *v4.50* Documentation Author... MARTIN ALVIS ; Building Permit # Fox Company ; �/_2—, ; 3995 Olive Hwy. ; Plan Check: / Date ; Or ov i l l e, CA 95966 916-533-2730 ; Field i ihec k / Date Climate Zane........ .. li---------------------- C:� �mpl iance Method...... MICROPAS4 v4.50 for 1995 Standards by Enerc� imp, Inc. M I C R:.OPAS4 v4.50 F i l e -ORS 1528E Wt h -CT Z 1 1 S92 Program -FORM CF -1R User#-MP1809 User�Fox company Run-ORS1528E ------------------------------------------------------------------------------- GENERAL INFORMATION ------------------- Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction. Type.... Glazing Percentage......... Average Glazing U -value.... 1528 sf Single Family Detached New Front Facing 90 deg_ (E) 1 2 Raised Floor 20.8 % o f floor area 0.52 Btu/hr-sf-F BUILDING SHELL INSULATION Component Frame Cavity Sheathing Insul Assembly Type Type R -value R -value R -value U -value Location/Comments Wal 1 Wood R-21 R-0 R-21 0.059 outside, garage Roof Wood R-11 R-27 R:.-38 0.025 Attic Door n / a R-0 R -n / a R-0 0.330 Solid Wood Floor Wood R:.-19 R-0 R-19 0.037 Orientation ----------- Front Left Left Left Left Left Left Bac k: Bac k: Bac k: Bac k: Back Bac k: Bac k: Fright Right FENESTRATION ------------ # of Area U- Pan- (sf) Value es (E:) ✓ 20.0 (S) w40.0 (5 ) t-20. 0 (S) -48.0 (S) 0,53. 0 (S) V20.0 (S:) .✓4. 5 (W) X1.0 (W) X16.0 (W) i4.5 (W) 20.0 (W) _46.0 (W) `4.5 (W) __20.0 (N) -7.0 (N) -7.0 0.510 0.510 0.510 0.510 0.510. 0.540 0.540 0.540 0.570 0.540 0.510 0.540 0.540 0.540 0.510 0.510 Interior Shading/ Description --------------- Drapes.Std Drapes.Std Drapes -Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std Drapes.Std law, Drapes.Std Drapes. S b Exterior Shading Nene None None Nene Nene None Nene None None Over- hang/ Framing Fins Type Yes Vinyl None Vinyl None Vinyl Nene Vinyl Yes Vinyl None Vinyl Nene Vinyl None Vinyl None Nene Nene Vinyl Vinyl s('�l i n y l Vinyl Y s Vinyl None Vinyl None Vinyl CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... CUSTOM HOME Date........ 05/01/98 MIC'ROPAS4'v4.5O File-ORS1528E Wth-CTZ11S92 Program -FORM CF -IR User#-MP1809 User -Fox Company Run-ORS1528E ------------------------------------------------------------------------------- FENESTRATION WATER HEATING SYSTEMS Number Tank: External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ---------- Storage Gas Standard 1 0.62 EF 40 R-0 SPECIAL FEATURES/REMARKS # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (s•f) Value es Description Shading Fins Type ------------------- Window Right ----- ----- ---- (NF_) ''8.0 0.540 2 --------------- Drapes.Std ----------- ---- Nene Nene --------- Vinyl Window Front (SE) '�8.0 0.540 2 Drapes.Std None None Vinyl HVAC SYSTEMS ------------ Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.800 AFUE Crawlspace R-8 Setback: ACSpiit 12.00 SEER Craw1spaca P.-8 Setback WATER HEATING SYSTEMS Number Tank: External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value ---------- Storage Gas Standard 1 0.62 EF 40 R-0 SPECIAL FEATURES/REMARKS CERTIFICATE OF COMPLIANCE: RESIDENTIAL Rage 3 CF -IR ------------------------------------------------------------------------------- Pro.ject Title.......... CUSTOM HOME Date........ 05/01/98 f MICROPAS4 v4.50 File-ORS152BE Wth-CTZ11S92 Program -FORM C:F•-1P. User#-MP1809 User -For. Company Run-ORS1528E COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code. of Regulations, and the administrative regulations to implement them. This certific=ate has been signed by the individual with overall design responsibility. When this certificate of c=ompliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks sec=tion. DESIGNER or OWNER•. Name.... STEVE OR:SILLO Company. OR.'SILLO CONSTRUCTION Address. 4296 OLIVE HWY. OROVILLE CA. 95966 Phone... 53'-1131 License. B-542034 Signed.. ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) (date) DOCUMENTATION AUTHOR: Name.... MARTIN ALVIS Company. Fox Company Address. 3995 Olive Hwy. Or c iv i 1 1 e, CA 95966 Phone... 916-533•-2730 Signed:. toil -Cie) (date) MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R Project Title.......... CUSTOM HOME Date........ 05/01/98 Project Address:....... LOT 3 SILVERADO DR. --------------------- BERRY CREEK *v4.50* ; Documentation Author... MARTIN ALVIS ***#* ; Building_ Permit # Fox Company 3995 Olive Hwy. ; Plan Check / Date Oroville, CA 95966 916-533-2730 ; Field Check/ Date ; Climate Zane........... 11 --------------------- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-ORS15 8E Wth-CTZ11S9 Program -FORM MF -1R -; f User #-MP 1809 User -Fox Company Run -ORS 15' 8E ; ---------------------------------------------------------------------------------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the c=ompliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatary measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES -------------------------- Design- Enforce- er ment *150(a): Minimum R-19.ceiling insulation. 150(b): Loose fill insulation manufac=turers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets i=EC: quality standards. Indic=ate type and farm. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doers and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstr ipped; all .joints and penetrations caulked and sealed. _ 150(8): Vapor barriers mandatary in Climate Zones 14 and 16 ~^ only. _ 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. _ 150(e): Installation of Fireplaces, Dec=orative Gas Appliances and gas logs 1. Masonry and factory -built fireplac=es have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots o is al lowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -IR Project Title.......... CUSTOM HOME Date........ 05/01/38 MICROPAS4 v4.50 File-ORS15.28E Wth-CTZ11S92 Program -FORM MF -1R User#-MP1809 User -Fox Company Run-ORS152BE ---------------------------------•--------------------------------------------•--- SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES -------------------------------------------------------------- Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback; thermostat on all applicable heating systems. 150(j): Pipe and -tank: insulation - 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R--12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes c=losest to water heater tank:, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank:. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sec=tions 1002 and 1004; ducts insulated to a minimum installed value -of R-4.2 or ducts enclosed entirely within conditioned spar=e. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is c=ertified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot .light. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously inuously burning pilot light (Exception: Non -elec=trical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES ----------------- Design- Enforce- er meat 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY page 1 C -2R - -------------------------------------------------------- Pro.ject Title.......:.. CUSTOM HOME Date........ 05/01/98 Project Address ........ LOT a S I LUEP.ADO DR. ---------------------- BERRY CREEK *v4.50* ; ; Documentation Author... MARTIN ALVIS ### ; Building Permit # ; FoxCompany - , 3995 Olive Hwy. ; Plan Check / Date ; Or civ i 1 1 e, CA 95966 ; 916-533-2730 ; Field Check/ Date ; Climate Zane........... 11 --------------•-------- Compl iance Method...... MIC ROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. M I iROPAS4 v4.50 F i 1 e -ORS 1528E Wt h-CTZ 1 1 S92 Program -FORM C: -2R User #-MP 180`3 User -Fox Company Run -ORS 1528E ; ------------------------------------------------------------------------------- M I C ROPAS4 ENERGY USE SUMMARY - Energy Use Standard Proposed Compliance - - (kBtu/sf-yr) Design Design Margin = = Space Heating.......... 14.23 12.36 1.87 = = Spar=e Cooling .......... 1 .39 14.96 -2.57 = - Water Heating.......... 14.01 13.02 0.99 = Total 40.63 40.34 0.29 = # Building complies with Computer Performance GENERAL INFORMATION Conditioned Floor mor Area ..... 1528 s f Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 90 deg (E:) Number of Dwelling Units... 1 Number of Building Stories. Weather Data Type.......... FullYear Floor Construction Type.... Number of Building Zones... Conditioned ned Volume........ . Footprint Area ............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Glazing U -value.... Average Ceiling Height..... Raised Floor 1 15805 cf 997 s f 997 s f 0 sf 20.8 % of floor area 0.52 Btu/hr--sf•-F 10.3 ft COMPUTER METHOD SUMMARY page 2 C -gip Project Title.......... CUSTOM HOME Date........ 05/01/98 -------------------------- MICROPAS4 v4.50 File-ORS1528E Wth-CTZ11S92 Program -FORM C -2R User#-MP1809 User -Fox Company P.un-ORS158E ; ------------------------------------ ------------------------------------------ Zone Type HOUSE Residence BUILDING ZONE INFORMATION ------------------------- Flc nor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area (sf) (cf) Units itioned Type (ft) (sf) 1528 15805 .1.00 Yes Setback:: 8.0 n/a OPAQUE SURFACES Solar Form 3 Location/ Tilt mains Reference Comments 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 No W.21.2X6.16 garage 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 0 Yes R. 38.'2X4.24 Attic 90 Yes None Solid Wood 90 No None Solid Wood 0 No FC:. 19. ' %. 16 FENESTRATION SURFACES --------------------- Vent SC SC Interior Open U-- Ap=t Mass Int Shading/ Type value Azm Tlt Only Shade Description Fixed 0.510 Area U- Insul Act Surface (sf) value R-val Azm HOUSE es Type HOUSE 0.510 I Wall 266 0.059 21 90 2 Wall 250 0.059 21 180 3 Wall 67 0.059 21 180 4 Wall 232 0.059 21 270 5 Wall 181 0.059 21 .70 6 Wall 292 0.059 21 0 7 Wa 1 ]. 168 0.059 21 0 8 Wall 17 .0.059 21 45 9 Wall 17 0.059 21 135 10 Roof 997 0.025 38 n / a 11 Door 20 0.330 0 90 12 Door 18 0.330 0 0 13 Floor 997 0.037 19 n/a SURFACES Solar Form 3 Location/ Tilt mains Reference Comments 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 No W.21.2X6.16 garage 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 0 Yes R. 38.'2X4.24 Attic 90 Yes None Solid Wood 90 No None Solid Wood 0 No FC:. 19. ' %. 16 FENESTRATION SURFACES --------------------- Vent SC SC Interior Open U-- Ap=t Mass Int Shading/ Type value Azm Tlt Only Shade Description Fixed 0.510 90 # of 0.88 0.78 Drapes.Std Area Pan- Frame Surface (sf) es Type HOUSE 0.510 180 90 1 Window 20.0 2 Vinyl 2 Door 40.0 2 Vinyl 3 Window 20.0 2 Vinyl 4 Window 38.0 2 Vinyl 5 Door 53.0 2 Vinyl 6 Window 20.0 2 Vinyl 7 Window 4.5 2 Vinyl 8 Window 12.0 2 Vinyl 9 Window 16.0 2 Nome 10 Window 4.5 2 Vinyl 11 Door 20..0 2 Vinyl 12 Window 16.0 2 Vinyl 13 Window 4.5 2 Vinyl 14 Window 20.0 2 Vinyl 15 Window 7.0 2 Vinyl 16 Window 7.0 2 Vinyl 17 Window 8.0 2 Vinyl 18 Window 8.0 2 Vinyl SURFACES Solar Form 3 Location/ Tilt mains Reference Comments 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 No W.21.2X6.16 garage 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 90 Yes W.21.2X6.16 outside 0 Yes R. 38.'2X4.24 Attic 90 Yes None Solid Wood 90 No None Solid Wood 0 No FC:. 19. ' %. 16 FENESTRATION SURFACES --------------------- Vent SC SC Interior Open U-- Ap=t Mass Int Shading/ Type value Azm Tlt Only Shade Description Fixed 0.510 90 90 0.88 0.78 Drapes.Std Slider 0.510 180 90 0.88 0.78 Drapes.Std Fixed 0.510 180 90 0.88 0.78 Drapes.Std Fired 0.510 180 90 0.88 0.78 Drapes.Std Slider 0.510 180 90 0.88 0.78 Drapes.Std Slider 0.540 180 90 0.88 0.78 Drapes.Std Slider 0.540 180 90 0.88 0.78 Drapes.Std Slider 0.54070 90 0.88 0.78 Drapes.Std Fixed 0.570 270 90 0.88 0.78 Drapes.Std Slider 0.540 270 90 0.88 0.78 Drapes.Std Slider 0.510 270 90 0.88 0.78 Drapes.Std Slider 0.540 270 90 0.88 0.78 Drapes.Std Slider 0.54070 90 0.88 0.78 Drapes.Std Slider 0.540 270 90'0.88 0.78 Drapes.Std Fixed 0.510 0 90 0.88 0.78 Drapes.Std Fixed 0.510 0 90 0.88 0.78 Drapes.Std Slider 0.540 45 90 0.88 0.78 Drapes.Std Slider 0.540 135 90 0.88 0.78 Drapes.Std COMPUTER METHOD SUMMARY Page 3 C -'R Project Title.......... CUSTOM HOME Date........ 05/01/98 MICROPAS4 v4.50 File-0RS1528E Wth-CTZ11S92 Program -FORM C -'R User #•--MP 1809 User -Fox �x Company Run -ORS 158E ------------------------------------------------------------------------------- OVERHANGS AND SIDE FINS ---Window---------Overhang----- ---Left Fin--- ---Right Fin— HVAC SYSTEMS Area Duct Duct Duct System Type Left Fight R -value Efficienc=y HOUSE Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 20.0 5.0 4.0 1.33 0_ n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 53.0 6.67 8.0 1.33 0 n/a n/a n/a n/a n/a n/a n/a n/a 12 Window 16.0 4.0 4.0 1.33 0 n/a n/a n/a n/a n/a n/a n/a n/a 13 Window 4.5 3.0 1.5 1.33 0 n/a n/a n/a n/a n/a n/a n/a n/a 14 Window 20.0 4.0 5.0 1.33 0 n/a n/a n/a n/a n/a n/a n/a n/a HVAC SYSTEMS WATER HEATING SYSTEMS Number Tank: External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.62 40 R-0 SPECIAL FEATURES/REMARKS Minimum Duct Duct Duct System Type Efficiency Location R -value Efficienc=y HOUSE Furnace 0.800 AFUE Crawlspaca R-8 0.900 ACSplit 12.00 SEER Crawlspace R-8 0.920 WATER HEATING SYSTEMS Number Tank: External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas Standard 1 0.62 40 R-0 SPECIAL FEATURES/REMARKS • HVAC: SIZING Page 1 HVAC Prbject Title.......:.. CUSTOM HOME Date........ 05/01/98 Project Address........ LOT 3 SILVERADO DR. -------------- ------ BERRY CREEK; *v4.50* 1 ; Documentation Author... MARTIN ALVIS Building_ Permit # Fox Company ; 3995 Olive Hwy. ; Plan Check: / Date Or ov i l l e, CA 95966 916-533-2730 Field Check/ Date Climate Zone ........... 11 ------------------------ C:ompl iance Method MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. M I C:ROPAS4 v4.50 F i 1 e -ORS 1538E Wt h-C:T Z 11 S9' Program -HVAC SIZING --- - f User#-MP1809 User -Fox Company Run--ORS1528E ------------------------------------------------------------------------------- GENERAL INFORMATION Floor Area ................. 1528 sf Volume ..................... 15805 cf Front Orientation .......... Front Facing 90 deg (E:) Sizing Location ............ BERRY CREEK:: Latitude ................... 39.7 degrees Winter Outside Design ...... 4 F Winter Inside Design....... 70 F" Summer Outside Design...... 94 F Summer Inside Design....... 78 F Summer Range ............... 35 F Interior Shading Used...... Yes Exterior Shading Used...... No Overhang Shading Used...... Yes Latent Load Fraction ....... 0.30 HEATING AND COOLING LOAD SUMMARY -------------------------------- Heating Cooling Description (Btuh) CBtuh> Opaque Conduction and Solar ...... 7456 2131 Glazing Conduction ............... 7651 2661 Glazing Solar .................... n/a 8125 Infiltration ..................... 11045 186 Internal Gain .................... n/a 2100 Ducts ............................ 2615 844 Sensible Lead .................... 28767 17723 Latent Load ...................... n/a 5317 Minimum Total Load 28767 23040 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design fac=tors such as air flew requirements, outdoor design temperatures, coil slung, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC: equipment. - MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 1 MF -1R ------------------------------------------------- Pioject Title.......:... CUSTOM HOME Date........ 05/01/98 Project Address........ LOT 3 SILVERADO DR. *# --------------------- BERRY CREEK *v4.50* It Documentation Author.... MARTIN ALVIS ****** ; Building_ Permit # f Fox Company 3995 Olive Hwy. Plan Check / Dat e Oroville, CA 95966 f 916-533-2730 Field Check/ Date Climate Zone........... li --------------------- Compliance Method...... MICROPAS4 v4.50 for 1995 Standards by Enercomp, Inc. MICROPAS4 v4.50 File-ORS1528E Wth-C:TZ11S9 Program -FORM MF -1R User#-MP1809 User -Fox Company Run-0RS1528E ----------------------------------------------------------------------=--------- Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding mi.nimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING,ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19.ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all .joints and penetrations caulked and sealed. 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with Sec. 151 meets CEC quality standards. 150(e): Znstallation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 2 MF -1P, Project Title........... CUSTOM HOME Date........ 05/01/99 1 MICROPAS4 v4.50 File-ORS1528E Wth-CTZ11S92 Program -FORM MF -IR User#-MP1809 User -Fox Company F.un-ORS1528E SPACE CONDITIONING, WATER HEATING AND PLUMBING SYSTEM MEASURES ---------------------------------------------------------•---•-- Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. ' �Z& 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and. Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (P,-12 or greater) or combined interior/exterior insulation (R-16.. or greater). 2. First 5 feet of pipes closest to water heater tank, non- on- recirculating recirculating systems, insulated (R-4 or greater) . 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value.of R-4.2 or ducts enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light.. 2. System installed with: a. At least 36 inches pipe between filter and heater for future solar heating. b. Cover for outdoor pools or outdoor spa. 3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnEce, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance with pilot < 150 Btu/hr.). LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. MAY 2 0 1998 BUTTE COUNTY BUILDING DIVISION 1. 11- u�: 95 16: U6 t:11 915 5.46 2654 X11/08/1995 16:08 '1-702-853-11461 5 i J.R. WILLIAMS CO Ur r 1" MM^ 11/08/95 16:00 TX/RX u0.1335 P.003 0003 i I 1111 Ud 11 9.5 1U: UU tAi 91U 54U Z O 111/08/1995 16:08 1-702-853-0401 i I.M. WILLI OFFICE MAX PACE 114 X At 11/08/95 16:00 ;TX/RX .40.1335 i il P.004 m LAND DEVELOPMENT BUILDING / ENVIRONMENTAL` HEALTH ;-PERMIT CLEARANCE coding Permit No. OWNES A.P. NAME:(11 leQ�Ln I (_L9CCJ-61 NUMBER: ago L9SG—C_? PRINT LAST NAME FIRST COUNTY ZONING DESIGNATION: %/-7 3 FLOOD ZONE: 5-Z.,/ K FLOOD MAP: 2 5 /3 APPROVED: CONDITIONALLY APPROVED: '1/ RESOLVE PROBLEMS PRIOR TO APPROVAL: PARCEL CREATION BY DEEDS OR MAP DEED INFORMATION: DATE OF CREATION: DEED REFERENCE: LEGAL ACCESS PROVIDED: YES NO LEGAL ACCESS REQUIRED: YES NO COMPLIES WITH COUNTY STANDARDS FOR DEED CREATION: YES NO COMMENTS/CONDITIONS: MAP INFORMATION: DATE OF RECORDING � °6`'� Z8flyv� LOT BOOK PAGE '�13�� COMPLIANCE WITH OLD SUBDIVISION LOT ORDINANCE REQUIRED? (MAP RECORDED PRIOR TO BOOK 17 OF MAPS AT PAGE 23): YES 'XI NO ., IF YES, MARK APPROPRIATE ITEMS) BELOW: A. Construct road to B. Meet parcel size required by zone. C. Meet current E.H.D. requirements. CHECK SPECIAL CONDITIONS WHICH APPLY TO MAP: ALL FEES TO BE PAID TO THE BU/LD/NG DIVISION UNLESS OTHERWISE NOTED. 1. Maintain a 50 ft. building setback from centerline of road. 2. Maintain a ft.building setback from right-of-way/centerline of 3. Maintain a 100 ft. leachfield setback from all existing wells. W CMZ L X 4. Maintain a /00 ft.4ea64fie+d setback from VSLI)a-4te S61i✓/4-eO /7!S/1'L /Zi2 , 5. Pay water tender fees in the amount of $ to Battalion Number of the Butte County Fire Department.. X 6. Meet the Fire Safe Regulations of Butte County and P.R.C. 4290. _ 7. Connect to a public water supply. 8. Connect to a public sewer system. I _ 9. Automatic fire suppression sprinkler systems shall be installed in all residential structures in accordance with the National Fire Protection Association Standard for the installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet Fire Department specifications, serves the parcel. 10. Pay T.D.D. (Thermalito Drainage District) fee in the amount of $ _ 11. Meet the requirements of the Department of Fish and Game for the preservation of oak trees. (See phone number below) 12. Obtain approval from the Department of Fish and Game for vegetation removal. Contact Fish & Game at 916-355-7010. 13. A traffic mitigation fee for each new or additional living unit shall be paid. Pay the amount of $ as stated in the Oroville Area Traffic Mitigation Fee Agreement. Payment to be nmWe to the Plf wdag DAnEsiai7. _ 14. All new residential buildings shall be constructed to comply with the requirements of the Uniform Building Code for seismic safety. Mobile homes shall be constructed on a permanent foundation system which complies with the Seismic Zone 3 requirements of the Uniform Building Code. _ 15. Deer Mitigation fees are to be paid, if such fees have been adopted by the Butte County Board of Supervisors. X 16. Pay school impact mitigation fees. X 17. A development impact fee for sheriff facilities shall be paid pursuant to the provisions of Chapter 3, Article II of the Butte County Code. _ 18. Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988 as amended. _ 19. If any cultural resources are encountered during ground disturbing activities, all work shall cease in the area of the find pending examination of the site by a professional archaeologist. This person would then be able to assess the site significance and suggest appropriate mitigation measures. X 20. 13u c. /)i AIC, s >v /Ic/Cdr.�sT�'zvc 7 Z -w 0l %sircC" JZc-S.rr ,vr /Zour-i,�� Aw R CP0 /✓yT.c� cf 3 -4 21. 41/ /1 Ala 6VC10a/l -r7V dd / cv7 XA,%-Zu N6-' SPA- a AIZIZes 7OW-s. X 22. B/L/On. /SS(//Y�✓L6/ D% /i!//G/9/NZ /�l�/7C /k -/P /NS77V-6 G /-N/J l-/ L 4- ,4 ,4 30 0 0 �,9 � �a ;✓ w�-rz Tl¢.v/� GyiTi-1 C DT /'�/>/� /l a d c�D jt / ?qT r/,vl �3- Co e�/NLrGT/0 �/S 24. 25 A10 iMdonna aw 311.f18 30 AIN1103 9661+IAON C13AI333H LD 9/95 - CAWP51 \FORMS. K\BLDGPERM.CLR COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT. OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE /��z A -- OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. LT� M) -`: COUNTY OF BUTTE BUILDING DIVISION ' 4. } DEPARTMENT.OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the/ above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately.ZZ A t fz/ //4 % 4� *-, - - f, C L// S ecl ,off ei r % C6 (e S Date v Inspector REV 10/J2 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE--�-�' OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office%when correction of work is completed. If yo ave any questions pertaining to this matter, or need"additional explanation, please conta is office immediately. G.I /D�P�7'O�5 1%w✓ "e- o v >% / Date �d Inspector 'C11554,241 REV 10/92 - COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. ! 4 1 Date Inspector ✓�%j2'� REV 10/ 2 x Date Inspector ✓�%j2'� REV 10/ 2 '��`,.`+i''�""T`Z"►it"}�'�r�'-+'v'' `�'�i. `:".t ::'�F'''".sr''r�r �. "�T'R""'� "iP+TFI _", .�. COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES ' 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE -Aw lee�,�o OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. 0/--, /t/y-/- !'.ecc, r iv S A LoC T"/, Date Inspector REV 4/92, LOERKE INSULATION CO., INC. JSULATION CERTIFICATE J 100 Silverado Dr. Berry Creek Number and 5treetify Lot 138 Plan 339 ounty Subdivision Lot Number DESCRIPTION OF INSTALLATION 1. ROOF Material Brand Name Thickness (inches) Thermal Resistance (R -Value) 2. CEILING Batt or Blanket Type Fiberglass Batts Brand Name Johns Manville Thickness (inches) 10.25" Thermal Resistance (R -Value) R30 Loose Fill Type Fiberglass Brand Name Johns Manville Contractor/s min. installed weight/ft sq. Ib. Minimum Thickness inches. _ Manufacturer's installed weight per square foot to achieve Thermal Resistance (R Value) 3. EXTERIOR WALL Material Fiberglass Batts Thickness (inches) 6.5" 4. RAISED FLOOR Material Fiberglass Batts Thickness (inches) 6.5" 5. SLAB FLOOR/ PERIMETER Material Brand Name Johns Manville Thermal Resistance (R -Value) R19 Brand Name Johns Manville Thermal Resistance (R -Value) R19 Brand Name Thickness Thermal Resistance (R -Value) Perimeter Insulation Depth (inches) 6. FOUNDATION WALL Material Thickness (inches DECLARATION Brand Name Thermal Resistance (R -Value) I hereby certify that the above insulation was installed in the building at the above location in conformance with the current Energy Efficiency Standards for residential buildings (Title 24,Part 6, California Code of Regulations) as indicated on the Certificate of compliance, where applicable. C. L.#499150 Item #s Item #s LOERKE INSULATION CO., INC. nstal inSubcontractor Co.Name) Or General . ontractor (Co. Name) Or Owner Installing Subcontractor Co. ame) Or General Contractor (Co.Name) Or Owner Item #s Signature, Date Installing Subcont (ctor_ (Co. Name) ) Or General Contractor Co. Name Or Owner