Loading...
HomeMy WebLinkAbout063-170-009RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 22-Oct72003 . 2003-0073939 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code ,Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. JOHN RUEDY 7 COUNTY CENTER DRIVE REAL PROPERTY OWNERILPSSOR OROVILLE BUTTE CA 811 WEST EAST AVE. # 7 CITY COUNTY STATE ZIP MAILING ADDRESS 538-7541 B IN PrRMIT N0. TELEPHONE WMBER CHICO BUTTE CA 95973 CITY COUNTY STATE -22 4759 HEIDI WAY 91096 INSTALLATION MAILING ADDRESS, IF DIFFERENT DEALER LICENSE NO. i FOREST RANCH BUTTE CA 95942 CITY COUNTY STATE ZIP SAME UNIITI�O� OWNER (if also property owner, write "SAME") A MAIIIDTG DRESS SAME CITY COUNTY STATE ZIP UNIT DESCRIPTION. BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE BUTTE CA 95965 CITY COUNTY STATE ZIP 03-1171 (530) 538-7541 B IN PrRMIT N0. TELEPHONE WMBER SIGNATURE OF LOCAL ACOTCY OFFICIAL D D & A CONSTRUCTION DEALER NAME (if not a dealer sale, write "NONE*) 91096 DEALER LICENSE NO. HBOS MANUFACTURING L 2003 ELATION 44 MANUFACTURERS NAME DATE OF MANUFACTURE MODEL NAME/NUMBER A/B H-021928 66728' ORE -445062/3 SERIAL NUMBERS) LENGTH X WIDTH INSIGNIA/LABEL NUMBER(S) REAL PROPERTY LEGALDESCRIPTION ASSESSORS PARCEL NUMBER AP # 063-170-009 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE -County Recorder CANARY - HCD PINK - Applicant GOLDENROD - Building Dept. 08/12/03 10:03 Escrow No. 209643 -JT Title Order No. 00209643 PARCEL I -A: BIDWELL TITLE + 530 821 5854 530 894 7647 EXHIBIT ONE N0.392 P003 A portion of Section 6, Township 23 North, Range 3 East, M.D.B.&M., more particularly described as follows: COMMENCING at the Southeast corner of said Section 6; thence North 0024'15" West along the East line of said Section 6, a distance of 440.42 feet, thence North 73057'54" West 295 feet to the point of beginning for the parcel of land described herein; thence South 22010'26" West, 629.58 feet to a point on the South line of said Section 6 Chet bears North 86 017'39" West, a distance of 487.14 feet from the Southeast comer of said Section 6; thence North 86017139" West along the South line of said Section 6, a distance of 268.62 feet; thence North 22010'26" East, 587.27 feet to a point at the Southeast corner of that certain parcel of land described in the. Deed to K. A. Gaines, et ux, recorded .lune 18, 1963 in Book 1252 of Official Records, at Page 220, thence South 73057'54" East 256.21 feet to the point of beginning. PARCEL 1-8: A right of way for road and public utility purposes over a strip of lend 60 feet in width, the centerline of which is described as follows: BEGINNING at the Southeast corner of Section 6, Township 23, Range 3 East, M.D.B.&M.; thence North 86017'39" West, 755.76 feet; thence North 22010'26" East, 310.55 feet to the end of said centerline. ALSO TOGETHER WITH a right of way for road and public utility purposes over the following described parcel of land: BEGINNING at the Southeast corner of Section 6, Township 23 North, Range 3 East, M.D.B,&M.; thence North 84017'39" East, a distance of 60 feet; thence Northeasterly In a straight line to a point on the East line of said Section 6 that bears North 0021'15" West, a distance of 60 feet from the Southeast comer of said Section 6; thence South 0021'15" East, 60 feet to the point of beginning. ALSO TOGETHER WITH a right of way for road and public utility purposes over a strip of land 60 feet in width, the centerline of which Is described as follows: BEGINNING at the Southeast corner of said Section 6, Township 23 North, Range 3 East, M.D.S.&M.; thence North 0021' 15" West along the East line of said Section 6, a distince of 940.05 feet to the end of said centerline. . ALSO TOGETHER WITH a right of way for road and utility purposes over a strip of land 60 feet in width, the centerline of which is described as follows: COMMENCING at the Northeast corner of the Southwest quarter of Section 6, Township 23 North, Range 3 East, M.D.B.&M.; thence South 0021'35" East along the West line of said Section 6, a distance of 1073.11 feet; thence South 68005'42" East, 743.85 feet to the point of beginning far said centerline; thence South 6016'420 East, 366.23 feet; thence South 47000'07" West, 378.66 feet; thence South 8304625" West, 450 feet to a point on the West line of the Southwest quarter of said Section 6 and the. end of said centerline. ALSO a right of way for road.and public utility purposes over a strip of land 60 feet in width, the centerline of which is described as follows: COMMENCING at the Northeast corner of the Southwest quarter of Section 6, Township 23 North, Range 3 East; M.D.S.&M.; thence South 0021'35" East along the West line of sold Section 6, a.distance of 1073.41 feet; thence South 68 005'42" East. 743.83 feet to the point of beginning for said centerline; thence North 26 023' 11 " East, 571.17 feet; thence North 10040110" East, 239.30 feet; thence North 6039'14" East, 225.72 feet; thence North 22021'01" West, 193.31 feet; thence North 83032'21" West, 252.10 feet; thence North 68°37'01" East, 267.82 feet; thence North 940'37'01 " Waat. 121 fact. mese or lace. eo a opine an Cha Seuthaantooly lino e4 eHa land eenvayed to tho County 08/12/03 10:03 BIDWELL TITLE � 530 821 5854 N0.392 P004 530 894 1641 of Butte by Deed recorded in Book 1139 of Officlal Records, at Page.453, records of Butte County, California, and the end of said centerline. BUILDING PERMIT NUMBER: 03-1171 Address or location of unit: 4759 HEIDI WAY, FOREST RANCH 95942 Legal Description of Real Property: AP # 063-170-009 SEE ATTACHED (g) Mo bilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: JOHN RUEDY Owner's address: 811 WEST EAST AVE. # 7, CHICO CA 95973 INSIGNIA OR HUD NUMBER: ORE445062/3 SERIAL NUMBER OR V.I.N.: A/B H-021928 MANUFACTURER'S NAME: HBOS MANUFACTURING LP YEAR: 2003 OFFICIAL APPROVING INSTALLATION. �� DATE: /6//7/0 %7 PHONE: (530) 538-7541 H.C.D. 513C 07/24/2003 10:10 5303433332 INTEGRITY HOMES PAGE 03 Y _ � � '` •'�` 5303.433332 •' `• ..,t:.,.:'-i;d•!_s.r"�^'^-,,;.,�••�'rx^;c'�:•rT'r:v.::��—rz�:_:•�_. •— e-:s:;aare.« J:;c-4•:.•-�;r:.=•:. .; •. .,.. - '��NT'A' ,,, •,. ._s.".^ ..: 86R:•>�:-. �..• :•� , :BUSINE6S,TRAK9PORTAT.ION 0 SIR O :-: T ,r:•=�.'y' :3'::yJy ::;:-; �t� h'rl TA'11:NL0_aCh:l fYG , Ctf2L ,,. T'. ;': _:_:.^ +•- a=:l, a �.. p j - �x~�• I.- -,-�? ,.t51�IfSft��l'29�Af��fD.�'�_ _.�.• .�;-wt-r^ x:.a,w.h.::. r<< { .c:;�.•.at' :e:;� ',li;>v�P✓^_�•.:s� �?`ir//��•x !: �t� 1y�19ry/TU1R DRI Pp�ry/±FSis11 :1:;_r?,�_.„,•s' \ tN.r _ ! 4 . � qI� .'.•'J;::. :,7. , •r.:' '•7;:I, if'�1+,•y;:i.4,7 =W.1 f71Y4� �i UFA TUR.ER CERTI1Fi _ . . a.::�.•,...1�:�...,::-,r:.�:i::,�,a„i;.,n��,,;�.a.:.::.;:;ri:,.',..a.5�.,;.;� • .'..''...L.Jr,CbIECK1E�'IIS.IS.A.DLPLI,CAIS.,MCA�EN7�f�,ORI01NAl�MC.0.N0, J APQU ACTQJ ED.W1 I (Spi'I lJUF1nIw&r'MA UFA'CTURED_HOUSING '.'a;;:;te.!•'=:`•;1.'•:: .;;a:'r.\�:., UMBER OF ' 2 PO ECTIOId - :(—'•$FsD SFAI61tE�AtvUlrY�tEl��Ip1 `MtdiQi *r 77: •�Q� : ; i., ..: . - ....faIJQ__ ._ NT 6®QUS1RA1S RT- A�yB--�`��S -? :'C ` AiIFR'7�AfOk�M. �:� w+viva- - :,��',•,....4.Isr :.,.: A°7. ^,y asf.., f": 'G ,h=Xs".•_..�'-tr�"v-t.; - .D •rv_e:•: ='::r ;n�T ":..::t=`-_"_'::1`.i•�z;r� ;:, :J:�,�-,�.:•'-•;�,�n._... '. - tt•,. tri"'Y.I °V" .T.;YII•:.y:_ i'k:•1•':.71 .,/.'•,. "C•Y:'r:'. '•!r:. I'r�1, �,t ANUFi4CTUR RNA • �! '� '• - -MANU TURER L'ICENSE'R • hi1HER;_ • ,.' •' .. - .rJ ., ,.: i,^:._..S M „ j.`;Y.'1•?.'Yr: �>,:• �t.t': �{' _: il•,f,{7i,. �. vltJ, I '3'ii>” C; : w;A•J n , ': ....... .... .. ..•... +.: .'' mss;?`l'��:`kr. ;:, ;r ,.; _ .?:: :.j.1 RBOS' .MAM:fJF•ACTURING '•I,'P10''7;4;913 t :.MANUFAGTURER.i4DDRE58; •,• ms:µ SUGGESTED REl'AdL PRICE: 'sC40_.Na -'EI,A4'''. ST.'; :'F ERMIS ON G ate 9783 $75,-47.5 PANUFACTURER''T,;RADENA,E; ;;; MODE L•NAME AND/OR NUMBER: DATEOFMANUIPtTURE; /'` ::I.L,�;r _ ,f.._. , y,ut._ � _ `�-l•11:� ,,yl�•�-,_ _ __� _.y.;•� ......4r-..., ^,; w: ,..., .,, , ,. _ __ .�1.+.,w�w __. 1. ... ... IL ;�y� , .... .. .s,. � .... � :.< nf•._�t.. •F/1•� ..y.••,`,' ..•jj':{i:Rd�.• •�.': ,_r{',Y•j.•.' . • NAIr I7 M FP K0 , 9RF@i R O) AR �. "' .: ....::.,•'".. .y+i;-.•:>_nt:d',; ,a.i.'. 1°45. :^•lti�'�'`rn u: S.r •a-•;.;.•..�;t.,,,i .. , y•nH"r....yr'!Y�,a:u1,-f.';:•1,'niy�,.pi_-'r•,�•,�1•y-:; r.:::::,'�.:.,r.,..:.,.n�•wir: •. h'.r-Y^".,t.!•7rh.^'(•^'•`... ij '•hF • L<w. • 1 •., • .:::.• • . ...: • ., i :..tib: :: • • . .:L •. T r So'.L sp ,✓kr•, - - h T .. s. ,�,. a S ,7 - rv. .' .-.',MStii w[:w.wir►.� :'.,. .1' . � u:•.. _.. . _:�.::..'..: ;, ...:.i: .:1 .':' � .. f:,/•' • � •/ . �. ,.� .... r... _ .1 .:_ _ Jr .... ,..' .`.p'J"'::ter. _„ .., .... ..y.. .. : ... •...._ ... _ _ - •.r:.:;cIiT�1' 14 Mtoo) 1. INVENTORY CRECJTOR.hIAME: .},L;,,�I •j 111 • VENTORY'CREDITORADDRESS:'1" ;;"V ..�.•�+,r...s,pJ.cii.i.}.... .:•`:,,'`'' ;.o+.:v ' �y.ne�•.�I•.P•�..,p.y-n�,n :.. .�. :i o : •: •� .. :: ,.. _, ,' !.; .. �, , I A'i:.J� iA .•�17����}-,�!-��S •/���.•-'- � G �J•W w .n...yW,i•, y,•.,^:y�•,w�..�.w,y:,•.:« "a�.!•r.•".`. ., -.. J ':7 ': +atJtf".r�ti:w�_.w..+..—_ T'�'',�,��.-�yyI .�...:w .•..ru,":..,,. .. • 1. _. •N �J�.L'%L J:I'i:,..,...w •. �a .1 1-..: :y .. .' . •.wry.:...\.,.. .J.,,..�WTURE.o•-,.'.,8.._.:... WIDTH 6EC71bT1•. :... ; MANUac1�1LR_ IAL:f�ll9�q`: - .r- y.r-:..ttCC1JNS`IGIAI�M1t7R (IUD LABEL NUMBER , w. in6 ... N. .. , ; • .: •'•.•. ..:. �..'; • .. , .. , ., •: '` Y.I.• ?: .7,r,-'"� ,"L• .A1 I •`•::�•+',! :a N .: .. = NDS I . JI ...1 �• '•' "''••:..: s.• >:�:.;:• 1}' „`f.; „�,..r. • INCWEB� , L�•Y.i::$�t rt',;: fy.�.y'i' `i '��ij' �:'N.. ''. i::�.o.'' _� �':::a=LL. ,r �:\:. ,; �,�:: �.�: 4.' �,• - ./r.., f, `,l?J:'I o•,�%,:,:: ,.S,•,W.•'G:, ,.1� 7. . n_.'::,:•�`-r•Ir Y,'-:po ._.r;:-•:.>•�:-;';._,r�..._.::r - �:,.•• k,.�:.,c F'�'' . • :: �. '�1�: I:rtT1'•'•�f'�'J t7"' ":.� ,. .i§�I -ifr' •r"i?i ; :m,' •:f ' is ' Li• v.> - ....�.e I` ._... _ 3G?rt;'i'.'•tkl 14'a,.S,' ., r'1... ;,'.1'SII!ii':ti:ty'1 I . .FTRAN$pORTER.NAME h • •• ':k�j:." :'rF )r:.f•,\: ;iF� :"tt: ., .., -:1 l%:"�•`.r>•:1: 7,.,�rJ .::�.. .:1'Y!I::: ':t;. F•..: TRANSPORTER ADDRESS: _..... __.. ,._. _....,....:..... ........ O 80X 16.3 fJ: • N,L%. I' - t ael ::.,...,r . I WK o:r .,,:��•''�:,�'_ ::�:: � .: •.,; � � .775 '...DE8T1NATtONFORIINLTDCSC0t18EDABOt/(:;. '� � .•1.`.`" - -s•"•-„"'J w�.. .`..n n MTEGRITY HOMES 3 13tree #SPLANADE - HICO c I QA1N6Ctd4t'pp1191tyCY BtJ*aftOiheTmvoof4h'tr8tatotiP4;�i,lFoj�rth9tthe9bavefede•e�e•fnre•d . : fib" •• ' .. ''ocuted'on_OAZ7'�"i,1O3 ' at! (Deter”— < 91GNATUFiEOFAUTHORIZEDA GENT=:.. (tS. ":irr?:7'r" ;;•�1� f�"'17:�'.{!.�i;?:;;.,..:. :ilrL 'i 117RfG'INAL"tC1NfCJ "• t?FIAVRii�l Y,,' iNIVEIj ,i�R�! GR ' 'ITdR; tl�Bt�TIiERE 19'NbME nr EN�FOIZWIaRD'�Tm 1+.fr:- !U tHA661+TR.RRE[T.. •_-... ... ' pOPr 4 (Wn IRE% :F.n R l o TWE:DBpA flclLffiT At P-V'tt ,F t08''•8X�`kAMENTG; OA'9Se2=182E,:1ii 1 fq or }dF.WE•'(6}:DJJtbKiiLL`�Y f LrSENkoa!)::f�:BElfillN i9 R•.; Q r, YMD,IVNIT NATt�110;,;,:•; Fr'i-,, -•_. p to TO 1T8 DE6fi � �, Tt9lS'.Atldfi�QAl`�• ,t`91a •-.��'z •:,r•. Fd8 :: <••> Slde lag :I.. r r ,., . ._ ... .. '.tib::: �F;:.�t,•_fy � _i �;. �..T, r•'•�'r:•.: , : ;:' �: ; •, •. STATE OF CALIFORNIA DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT DIVISION OF CODES AND STANDARDS REGISTRATION AND TITLING SECTION STATEMENT OF FACTS This unit is a: Mobilehome Commerical Coach Floating Home Truck Camper Decal (License) No. (s) Trade Name LE LA -n 6 KI Serial No. (s) I/ We, the undersigned, hereby state that the unit described above: be place—<A 4'e -% o. 01 3 1-1 o— boq by c�.u�''rnpriz.a-tiar� Affiant further agrees to indemnify and save harmless the Director of Housing and Community Development, State of California, and subsequent purchasers of said unit, for any loss they may suffer resulting from registration of the above- described unit in California, of from issuance of a California certificate of title covering the same. I / We certify'' under penalty of perjury that the foregoing is true and correct. `[ Executed on -'21 -- d3 at: Oroville ,California (Date) (City) (State) Signature of each affiant Printed name of each affiant Address 1740 Feather River Blvd. City Oroville HCD 476.6 (Rev 11/86) Michelle Freel, Office Manager State California 08/12/03 10:03 BIDWELL TITLE 4 530 821 5854 530 894 1641 RECORDING REQUESTED BY: Fldelity National Title of California Escrow No. 200643 -JT Title Order No. 00209643 When Recorded Mail Document and Tax Statement To: Mr. and Mrs. John Ruedy P.O. Box 2123 Chico, CA 95927 NO.392 P002 2 03---Qlf� 1 X25$ OfficialRecords1 TAX FEE 45.75 CountOf I NONUMEN 10.00 MIM 09 J. GRUBBS order I I Kathy I. Page 1 of 3 APN: Q63-170-009 GRANT DEED SPACE ABOVE THIS LINE FOR RECORDER'S USE The undersigned grantor(s) declare(G) Documentary transfer tax Is $46.75 1 X ) computed on full value of property conveyed, or I ) computed on full value less value of liens or encumbrances remaining at time of sale, f JG I Unincorporated Area City of Biggs j FOR A VALUABLE CONSIDERATION, receipt of which is hereby acknowledged, Gary Friedman as his Sole and Separate Property hereby GRANT(S) to John Ruedy and Agnes B. Ruedy, husband and wife as Joint Tenants the following described real property in the City of Biggs County of Butte, State of California: SEE EXHIBIT ONE ATTACHED HERETO AND MADE A PART HEREOF DATED: January 29, 2003 STATE OF *CALIFORNIA COUNTY OF —IE5 -�e—rsonally appeared 7M 0 personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within Instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(les), and that by his/her/their signatures) on the instrument the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument, Witness my ha d official seal. Signature U tf 0 J.TUNISON ,T NOTARY PUBL104A(.IFORW v 8MG ODUNlY O IdYcome.BxPfRE9 star,.a. eoo9 MAIL TAX STATEMENTS AS DIRECTED ABOVE M-213 (pcv 7/96) GRANT DEED 08/12/03 10:03 BIDWELL TITLE 4 530 821 5854 N0.392 P003 530 894 1641 Escrow No. 209643 -JT Title Order No. 00209643 EXHIBIT ONE PARCEL I -A: A portion of Section 6, Township 23 North, Range 3 East, M.D.B.&M., more particularly described as follows: COMMENCING at the Southeast corner of said Section 6; thence North 0024'15" West along the East line of said Section 6, a distance of 440,42 feet; thence North 73 °57'54" West 295 feet to the point of beginning for the parcel of land described herein; thence South 22010'26" West, 629.68 feet to a point on the South line of said Section 6 that bears North 86 017'39" West, a distance of 487.14 feet from the Southeast corner of said Section 6; thence North 86017139" West along the South line of said Section 6, a distance of 268.62 feet; thence North 22010'26" East:, 587.27 feet to a point at the Southeast corner of that certain parcel of land described in the. Deed to K. A. Gaines, et ux, recorded June 18, 1963 in Book 1252 of Official Records, at Page 220, thence South 73057154" East 256.21 feet to the point of beginning. PARCEL I -B: A right of way for road and public utility purposes over a strip of lend 60 feet in width, the centerline of which is described as follows: BEGINNING at the Southeast corner of Section 6, Township 23, Range 3 East, M.D.R.&M.; thence North 86017'39" West, 755.76 feet; thence North 22010'26' East, 310.55 feet to the end of said centerline. ALSO TOGETHER WITH a right of way for road and public utility purposes over the following described parcel of land: BEGINNING at the Southeast corner of Section 6, Township 23 North, Range 3 East, M.D.B.&M.; thence North 84017'39" East, a distance of 60 feet; thence Northeasterly In a straight Ilne to a point on the East line of said Section 6 that bears North 0021'15" West, a distance of 60 feet from the Southeast corner of said Section 6; thence South 0021'15" East, 60 feet to the point of beginning. ALSO TOGETHER WITH a right of way for road and public utility purposes over a strip of land 60 feet in width, the centerline of which Is described as follows: BEGINNING at the Southeast corner of said Section 6, Township 23 North, Range 3 East, M.D.B.&M,; thence North 0021' 15" West along the East line of said Section 6, a distance of 940.05 feet to the end of said centerline. . ALSO TOGETHER WITH a right of way for road and utility purposes over a strip of land 60 feet in width, the centerline of which is described as follows: COMMENCING at the Northeast comer of the Southwest quarter of Section 6, Township 23 North, Range 3 East, M.D.B.&M.; thence South 0021'35" East along the West line of said Section 6, a distance of 1073.11 feet; thence South 68005'42" East, 743.85 feet to the point of beginning for said centerline; thence South 6016'42" East, 366.23 feet; thence South 47000'07" West, 378.66 feet; thence South 83046'25" West, 450 feet to a point on the West line of the Southwest quarter of said Section 6 and the. end of said centerline. ALSO a right of way for road and public utility purposes over a strip of land 60 feet in width, the centerline of which is described as follows: COMMENCING at the Northeast corner of the Southwest quarter of Section 6, Township 23 North, Range 3 East; M.D.B.&M.; thence South 0021'35" East along the West line of said Section 6, a.distance of 1073.41 feet; thence South 68 005'42" East, 743.83 feet to the point of beginning for said centerline; thence North 26023'11 " East, 571.17 feet; thence North 10040' 10" East, 239.30 feet; thence North 6039'14" East, 225.72 feet; thence North 22021'01 West, 193.31 feet; thence North 83032'21" West, 252.10 feet; thence North 68037'01" East, 2.67.82 feet; thence North 64 °37'01 " Wont. 121 foot. mora or loco. co a point on tho seuthaaetorly 11na of tha land aanvovad to tho County 08/12/03 10:03 BIDWELL TITLE 4 530 821 5854 530 894 1641 N0.392 P004 of Butte by Deed recorded in Book 1139 of Official Records, at Page 453, records of Butte County, California, and the end of said centerline. NOTES r RESIDENTIAL > 063-170-009 03-1171 PERMIT NO. RUED -Y, JOHN ;41 HEIDI WAY, FOREST RANCH Cont: D & A CONST NEW MH PERM FND NEW SITE i a THE HCD FORM 433A FOR THIS MH CANNOT BE RECORDED UNTIL ONE OF THE FOLLOWING HAS BEEN TURNED IN TO THE BUILDING DIVISION: (1) LICENSE PLATE(S) OR DECAL (THE INSPECTOR MUST RETREIVE). (2) STATEMENT OF FACTS (ONLY ON NEW MH'S). INSPECTOR TO VERIFY SERIAL & LABEL #'S. ll_ CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED (Date) Signature J=OK -0 = Not OK - = Not Applicable . = Not Ready MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or / /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 ate Card B-1 Date Card B-1 Date, Card B-1 Date MOBIL ME INSTALLATION (Plans) OK a sept #'s on' equireme etbacks-E ents ootings; Siz acing -Ma a Line 3. Gas; MH Test -Demand -Valve -Connector 4.,A Electricity; MH Test -Crossovers -Breakers -Clearances rain; MH Test -Fall -Flex Connector . Water; MH Test -Regulator -Connector Oftater and Sewer Connected -C/O to Grade -HD Approval Gas and Electricity Tagged . Tie Downs -Typo -Installation Cert. 10. Exits; Insp.-Sketch 11. Cwt. of Occupancy VY'(,` T" - Date _ - Q Card B-1 t ' Date Card B-1 Date Card B-1 Date Card B-1 Date PERMANENT END RVCTEM (ONLY) 1. Zoriieauirements-Setbacks-Easements Line B! Gas; MH Test -Demand -Valve Sr' Electricity; MH Test . Water; MH Test 7 ater and Sewer Connected . §, and Electricity Tagged _ V Exits 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date 6 1 117 Card B-1 Date Card B-1 (041 iY1 od�.e�� ij Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails i 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 a Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater i 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test j 11. Light Niche ii 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = Not OK Re RESIDENTIAL (Single & Duplex) - = Not Applicable . =Not Ready Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 16. Insulation Date FRAMING (Continued) Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 52. Garage Fire Protection Framing -RC Channel 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 23. Fire Sprinkler; Test 60. Shear Walls; Nailing -Bolts Date Card B-1 Date Card B-1 Date 63. Infiltration -Walls -Windows Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Card B-1 Date Card B-1 24. Fixture & Transformer Clearance -Ins. Protection FINAL (Plans) OK except #'s 25. Elec. Receptacles Spacing -Lights & Switches at Doors 64. Ext. Steps -Door & Sidelight Protection -Landings 26. Size Boxes & No. of Conductors Stapled 27. Romex Installed Close to Edge of Studs & C.J. 67. Bedroom Exiting 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI 70. Stairs & Rails 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or All Insulated Neutral O Yes CI No 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 32. Service -Riser Conductors & Ground Main Disconnect 33. Equip. Clearances Panels-Motors-Mech. Equip. 76. A.C. Duct in Garage -Damper 34. Clothes Closet Light -Shower Light -Spa Light 35. Smoke Detector 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection Date Card B-1 Date Card B-1 Date 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 83. Following Instld./Drive O Yes 0 No/Walks 0 Yes O No/Planters O Yes O No 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 89. Ventilation Throughout House 40. Attic Access & Platform if Furnace in Attic Date 91. Corrections from Previous Inspections Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors 96. Fire Sprinkler 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound Date 43. Bearing Walls over Girders & Floor Nailing Card B-1 Date Card B-1 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes _ 83. Following Instld./Drive O Yes 0 No/Walks 0 Yes O No/Planters O Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date,- Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: INTER-DEPARTMENTAL MEMORANDUM NKI(I TO: BUILDING DIVISION, OROVILLE 0 FROM: /' x'!22 L,l lJ5 / ��, ENVIR. HEALTH, CHICO DATE: RELEASE ENV. HEALTH HOLD ON BUILDING FINAL F OWNER NAME: SEPTIC: L/ AP#:��p3 `%O�t`% ADDRESS/LOCATION: Comments: GL/memos/releasehold ,....�r,..tic.r-"'.ti:,.._..s!ai�..�ti.-.-..rpt....-....-w.c—�-._--s-.4.-.,r'4:�.,•v�..�_.,,._.--rti.:- ^.-.y.__.--.v.�..-� COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE ER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. l No 4c,c e �, �-n 1g.>rAt IF Dates?_ Inspector REV 10/92 COUNTY OF BUTTE • .. • • • • BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE c�3-Ii�-1 OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. ' Date G ~�3 Inspector �/ r REV 10/92 ACOUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 • Telephone (530) 538-7541 (Rev. 12/96) APPLICATION AND PERMIT (J ASSESSOaP�I,IJL (7-009 l / ZONING TM -5 BUILDING PERMIT OWNER Joh John Ruedy 345-3066 TELEPHONE SO. FT. OCC. BUILDING VALUATION 1769 R 95 526.00 OWNER'S ILIN1G ADDRESS W East Ave #7 Chico CA 95973 CONTRACTOR'S NAME D & A Construction 821-585 TELEPHONE CONT 8g8 W. Onstott #J Yuba City,CA 959993 CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 95 526.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee 621.50/2 $ 310.75 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 23.00 BUILDING ADDRESS Heidi Way, Forest Ranch Energy Plan Checking Fee $ $ PERMIT FEE $ 353.75 LOT NO. SUBDNISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 15.00 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: NH isntall on Perm fnd-new site Gas piping system 1 - 5 outlets 15.00 19.00 Building sewer 15.00 19-00 Mobile Home I S I G W 920.00 PERMIT FEE $ 65,00 ELECTRICAL PERMIT Filing Fee 20.00 Main Service '..A OR LESS 23.0023. 00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business an Professions Code, and my license iSn rce and effect. ' /�^���777 �J � �� /) License Class Lic. No. --71 C �-F� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO lOooA 46.00 NEW CONST. DWELLING OCCUP. SO OR ADONS. ( a ACC. BLOS. 3.5QFT; NEW CONST. MULTI -OUTLET NON-RESID. @7.50 POWER APPARATus 8 SINGLE OUTLET CIR. E(, OCCU OUTLET OR FDCTURES SAL @ .5Q LNS RA. 5.00 Ex. Occup. oFlxuTiErs L10E Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $43.00 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. V1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' cope sati n n rr' r and policy number are: Carrier Policy Number (The above sections need not be complete d the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. W X��_ Date4/'A /0 Signature of Appli ant - ❑ Owner X Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and de o ition or construction of structures over 3 stories in height. O MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE EE $461./5 N_T�QTA�L CIJF LFARCELJPDSU This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated abov for which fees have been paid. ate t�3 PERMIT EXPIRES ON 01to Receipt No. WHITE-D.D.S.-B.D. CANARY -ASS ES SOP PINK -INSPECTOR I JOLDENROD-APPLICANT PAF COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILD NG DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (530 538-7541 P 12196) APPLICATION AND PERMIT SCSI OR In BUILDINGPERMIT � OhI-1 1ergLP TE"'"O"e _N"5.3c . OC SO FTCC. BUILDING VALUATION I-1 S� IS ._ ... __ RS MAiU NO �w„� � l W �E_ was+ Pry �n.ue -� —1 Ch ► csJ ct5913 - 1 _ CO•rTRACTOR S NAW I TELEP-ONE 'Di AADDRESS ,r-CG��b'rcuc.-4-con C3TiS raUCT,ON LENOEA LE, DER SUNG ADDRESS __ Fireplace I ”-- Total Valuation Is / ARCWIECT OR ENGR.EEA UCENSE NO Filing Feb S 7,1 r„ Permit Fee - � b -31 p Plan CheckingFee b (� - AAC-TECT OR ENGWEEAS vAZUNG AOORESS &.404rG ADDRESS �`�` �. - Energy Plan Checking Fee b U b - PERMIT FEE S urNO. sueoNsoNSNAUE ►ARGEL MAP PLUMBING PERMIT Filing 20.00 USEOFSTRUCTURE 3a t7 A _ SF ❑ Duplex ❑ Mobilehome W' Other SPECIFY Each Trap 7.00; _ Soler or heat um water heater 23.00, Water piping 1 5.00,/ Each gas water heater or vent 1 5.001 TYPE OF WORKG � New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation Other ❑ a Describe Work: m I h I (•t fj+att 6�1 a ym -�jzd wskl# I i1Q_L� S I-�e — as i in stem 1• S outlets � 1 5.001 Building sewer 15.00: — Mobile Home � S � C' I W � I � @20.00' PERMIT FEE I s i ELECTRICAL PERMIT I I Fling Fee 20.0 Ma Service eoav OR LESS moA OR LESS I 23.00 Sry U'►�l �O I�� . °L(l- i (j 215 D -Z:;, JWT r -x O 3� s- C_ • P E.R�41IT FEE PAS � � 5^ . K/1 SHERIFF OTHER J AAk6V 4TT RECEXWr.> _ %r.� - « TO N �. 21h" GONMVTl�R > Main Se �ce nw To 1000A I 46.00: - NEW CD.67. r Ow31►+G DGGUP. SO. OR ADONS. a Kc. OCC I 3.5c" rT.: � OI AES � TFGIiiLET I 97.50; POWER TI/i I S"GLE 0 IR I I EX. OCCU OUnzr OR Fwn FIC's n%APPIxs. OR I Esc. Occup. DT1EO ETt RfS10 5.00 EA 1 _ Temporary Service i 23.00 . Mobile Home Facilities 1 20.00 Misc. Wirin ! 23.00. i PERMIT FEE _ -,MECHANICAL PERMIT Fling Fee 1 20 C7 Heatin I - CoolingI Hood 6.50: Ventile:ion � PERMIT FEE S Mobile Home Installation Fee b Energy Inspection Foe b '� °cc I eoNar nrE TO L FEE r I MAL 0. rEES r n o cor ► c I This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES 6N Mere) f ReceiptNo. WHITE•O.O.S.•B.O. CANARY -ASSESSOR PINK -INSPECTOR OOLOENROO•APPLICANf COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET J,,^, OWNER: P �- ASSESSOR PARCEL NUMBER 6A� Proposed Building Use: ,(W— M l l j` ta) `Fo K)0 S 6 Counter Technician Date:' Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. .. Plot plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! To5. Energy compliance desi n and supporting documentation in duplicate. J 6. Manufactured homes: ),,bata sheets and installation instructions'k Marriage line informationWFloor Plan, (,Pgie down or foundation plans, all in duplicate. $ ❑ 7. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicatj. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. i . Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required items are received. Date Received By ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Plot plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings......................................................... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... .Hazardous Material Form ...................................... _ ...... ............... 13. jR a* *ng items needed to issue the permit. (May require additional plan review upon receipt of the following items.) I1 14. Fees as shown on the attached Schedule of Fees Due Sheet ....................................... 3 . Statement of Intent for Non -heated and A/C Buildings ...................................... 6. ' anitation and plot plan approval from the Environmental Health De artm nt in, `P7. City of Chico Plumbing permit........................................�.. 18. California Department of Forestry plan approval paid. Sent O ❑ 19. Planning approval for (A) Use: D (B)Parking:(C) Parcel Check: ❑ Contact Land Development about ❑ Improvements, ❑ Drainage ............................... P21. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). re -Inspection for required ................ ❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 24. Worker's Compensation Carrier and Policy Number ..............:.............................. ❑ 25. Owner -Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... . Let ter of Signature authorization.................................................................... .. copy of Agricultural Acknowledgment Statement ..................................... . Manufactured home utility clearance............................................................... ,a ❑ 29. Existing violations and/or expir { a ❑ 30. ❑ Grant Deed, ❑ M.H. e t o cts Letter from Legal Owner, heck to H.C.D. ' c� ' ❑ 31. Other: When issued Telephone and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: Applicant: � '�.�I+T�-\�XI - a3 1. Index permit application for the above items numbered: It V Plan Check Letter 2. Additional items required Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ cou1pt^er,rby Date: Plans reviewed by: Date: Plans approved by: / Date: Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Date: Yellow: Building Division TO: Building Dep rt�nent FROM: Environmental Health SUBJECT: Sanitation Clearance E.H. USE ONLY n attached you Plan A d B.D.rl Y OwA er L cation AP# Plan Approved for: Sewage Disposal L--' Water Supply: Public Private Well Clearance for dwelling. Other Hold final for: "\ FIX141— 0// S&,�027 C`�- .K. for: NOTE: c- Environmental Health Specialist Date 8/96 COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 SCHEDULE OF FEES DUE �,►/� /U / g� /) OWNER 1 _ A.P. # (/(lJ�� �! L)u� PROPOSED BUILDING USE ' V L-' �%� i �����= 5/`� DATE '1- - 3 �, � im `�' RECEIPT # DATE RBC. 1. BUILDING PERMIT FEES � % Balance Due ....................... Additional Fees Due ................. $ Additional Fees Due ................. $ Revis d Plan Checking Fee .............$ L DISTRICT FEES (pard at District Office) (Available after Plan Check) 3. SHERIFF FEES (paid at Building Division) Residential ...................... •$360 - $ Units Commercial (sq. ft.) ............... x $0.03 = $ Sq. ft. 4. URBAN AREA FEES (paid at Building Division) Residential ................... -x-=$ # Units Amt. Commercial (sq. ft.) ............ -x-=$ Sq. ft. Amt. 5. RECREATIONAL DISTRICT FEES (paid at District Office) (Available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) S INSPECTION AND PLAN CHECK $89.00 d at Building Division) 8. WATER TENDER FEES (Battalion # $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER VW6 At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. 07 APPLICANT DATE tet' R> d 3 Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner ' (Rev. 6100) Building Permit Number: Q3-11%1 Owner Name: ueG Residential Construction Requirements IMPORTANT This set of plans and specifications MUST be kept on the job site at all times and it is unlawful to make any changes or alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship shall be in accordance with recognizedood practices and of a quality prescribed for the specific use in the 1998 California Building Code (1997 U.B.C), 1998 California Plumbing Code ( 1997'U.P.C.), 1998 California Mechanical Code (1997 U.M.C.) and the 1998 California Electrical Code (1996 N.E.C.) COMPLY WITH ITEMS CHECKED BELOW aYour parcel lies within a designated 100 -year flood plain. Finish floor, electrical, H.V.A.C. equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required - - - -- ------ Note: We will normally accept the foll6wing as'compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24" above grade, or engineered design required). I Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than I foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. Page 1 of 2 Building Permit Nu ber: Owner Name: Parcel lies within the State Responsibility Area (SRA). Comply with attached requirements. ❑ Fire sprinklers are required in this structure. ❑ The following parcel map requirements shall be met: All structures and equipment including overhangs shall be clear of all easements. A setback of DC7 feet from the side and _. feet from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the edge of the right of way shall be clear of structures and equipment except for a 2 foot overhang. Expansive soil may be encountered on this site. This condition may require the foundation to be designed by a California registered engineer or licensed architect. Page 2 of 2 N goo ALL STRUCTURES AND OVER aMCS SP L SE CI -7 OF ALL EASE A SE r BAVi O �Po C" b. FROm THE SIDE AND '-2'0 FT.-,- 0?? e : ; FJIIR PPOPERTY LINES AND SM" BE CLEAR OF w�UC'� �� � `� c��=�D '- JIENT EXCEPT FOR A 2 FT. EAV2 VER sAc' 3. 70nvx-�-) �e&A 4Q- % (Jk� qo`'t 9 (� lzo PLC too c� 1� ewDI zQ.1vV, REVIEWED BY BUTTE CO. FIRE DEPT. CALIF. DEPT. of FORESTRY C3 approved as submitted approved with conditions per attached sh et. Date gignature �3-/7D DDI AP# CDF FIRE SAFE REQUIREMENTS PERMIT # N E Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made apart of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. [`1" 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Drivewav Standards 273.02 Surface. All driveway surfaces and structures (bridges,. 1273. 07 culverts and other app -rte -cant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [t,1 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius 1. No roadway shall have --a horizontal inside radius of curvature of less than 50 feet and additional sur- face width of 4 -feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. [vI 2. The length of vertilcal. curves in roadway-s.':exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [L]--__1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 / feet long with a minimum 25 foot taper on each end. Mi7 [ 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of - 3--, D� 3-12�2- DD 03 �y-, � AP # PERMIT # NAME [11273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates Gate entrances shall be at least two feet wider than the roadway it serves. 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [� 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification /1276.01 Setback for Structure Defensible Space. [►�1' 1. All parcels 1 acre aild larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from 411 property lines and/or the center of the road. [ ] 2. For parcels less than 1 acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. [ 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r fi:ial inspection of a building permit. Page 2 of 3 AP # PERMIT # NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [ ] If Building Setback is Less Than 15 Feet Choose any 3 of the following: Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves Interior automatic sprinkler system per NFPA 13D Glass area not to exceed i0k of wall area toward property line with insufficient setback - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Da a Signatur Page 3 of 3 -02118/2003 14:13 15415671484 MARLETTE HOMES PAGE 05 fl u CC r, Clq C -o Za" CC I `TTE COUNTY MUILDIING DEPARTME `' = s p MOBILEHOME SUPPORT DATA Mobile Manufacturer: MarleA-k-e- Manufacture Year: If other then single wide, fumishSetup Model Number: E lA-MCA l Width: Qtplg' (ft) Length:(gyp (ft) Tagalong or Expando Size X On all mobilehomes manufactured after October 7, 1973, furnish manufacturer's installation manual and structural setup sheets. FOOTINGS: Wood pressure treated or foundation grade r<] Other: SUPPORTS: Concrete block [k] Other: Provide Tie Down Specifications for all Mobilehomes: CPN r �y ILNaa Line 1 Piers: Line 1 Openings Size minimum: ]XI I Size minimum: ] x Spacing maximum: Each side of openings " From ends -max: with width over: " Line 2 Piers: Line 4 Piers: Size minimum: 41 x ol Size minimum:]XI I Spacing maximum: $ o " Spacing maximum: " From ends -max: 2' o From ends -max: " Line 3 Roof Loads: Size minimum Location (from rear): Line 5 Roof Loads: Size minimum Location (from rear): BUTTE COUNTY BUILDING ®EMri I i A P, L9 R 0 ! F: 10"' MOBILEHOME INSTALLATION DATA 1) Owner's Name: -JDn 2) Assessor's Parcel Number: �y3 — 1-1 O ^ 00 q 3) Installer's Name: c A Cc,nS� 4) Is the site currently under permit? Yes [ ] No [X] Permit No. 5) Is the site an existing site? Yes[ ] No [?< ] (If yes, furnish two plot plans). 6) What is the electrical rating of the mobilehome? OCA Amperes. 7) What is the mobilehome site circuit breaker rating? 200 Amperes. 8) What is the electrical rating of the mobilehome site? 200 Amperes. 9) Is the main service remote from the mobilehome site? Yes [ J No [k] if it is, what is the rating? Amperes. 10) Is there any other electrical load to be served by the mobilehome site electric service (ie well, garage, etc.)? Yes [X] No [ ] If yes, please identify the load and size: a) The mobilehome site: Load- U.)AE1[ Amperes- 20 b) The main service: Load- Amperes - 11) Type of gas service at mobilehome site: Natural [ ] Propane VA None[ ] 12) Size of gas pipe at the mobilehome site from the meter or tank: 3/4" . 13) What is the gas pipe length from the meter or tank to the mobilehome? 25 -(ft.) 14) What is the mobilehome gas demand? B.T.U. • "(This information is not required if the pipe length is less than 6 feet on natural gas or less then 50 feet on propane). THE OTHER SIDE OF THIS FORM MUST BE COMPLETED IN ORDER TO PROCESS THIS PERMIT APPLICATION MJLo `"" �L11 r' F-4, 'I W L R L r Jon. 1 l � _ 'I W L R L r Jon. yo AMIR Tw f 1JyfL'' Et -9 6 a R£VPRf�HIT�IY ri�Yl X 15; °M� �� 02 2---------------------� lgi97�7rC trod A' calf G G ; L 94-& 0 6P -3-i 42-8 BP 4 I �-0_ 57-4. 8P-�5 � —&r -Tl i@t iGf� iCF.I �"lfi C'! i!'ilU' I t n�vniv �iF hf• ei i A —L r%r%rl Lt f trc trt M, ra t'71— D:.h Zirr F 9 ut un ry �„ai _ !""1..—. M:._I �I 6 - T i r�i�e i-e�l E ��� _ V, :'i!i ie•.if `i j C.'L. vii't;Fi f� `.Ei '. i'v f`� t i] irr. CZt ee. i.^— � -- v�.`t4 J'I � a WT Q b 2 d � �99Y3' W i— J LtQ lzr a C LO Lo v LO L -J Jon. yo AMIR Tw f 1JyfL'' rI 1 Alt -9 6 a R£VPRf�HIT�IY ri�Yl X 15; °M� �� 02 2---------------------� lgi97�7rC trod A' calf MA27MG ; L 94-& 0 6P -3-i 42-8 BP 4 I �-0_ 57-4. 8P-�5 � —&r -Tl J i 6 - T rti•�—r r�i�e i-e�l E ��� _ -- � a WT Q b ilk? �99Y3' L -J F f-0 Ld 77 0 x Ul F- Ld --I CE Nr Lo Lr) r L r� A 7' f N 1 ROOF ZONES � Tik IlfL s, C 7iOf fC GAS !k!Lr7T BY PIER) fA op LOCATION 20# 2 DRAIN OUTLET 60# BP -1 26'-2`' 0* -0" 2931 3 DRAIN X—OVER 6840 @ 26'-2Is @ YY 20'-1 4 WATER INLET 10880 e 3t -0't n', z- v I 1prl I 'j u v'j 5 WATER X—GVER nf 11 A a%j I -T @ M 1-8tf & iS-4 11 6 ELECTRICAL INLET 7148 0 13%-6Y4F; @ 12'-04" 7 ELECTRICAL1)1!X—OVEROVF 4666 @ 20'—B @ 13e-4" 8 H AT rT Y -R 1 4498 0 k @ 1 " 4 9 DRYER VENT 2015 @ 8'-91 ROOF ZONES (LOAD IN POUNDS SUPPORTED BY PIER) BP—# LOCATION 20# 30# 40# 60# BP -1 @ 0* -0" 2931 3908 4885 6840 13P-2 @ 14'-8" 4663 6217 7771 10880 I UY LjV%J fa n', z- v I 1prl I 'j u v'j k I � I li & j i Q.4 11p U-T-pu nf 11 A a%j I -T BP -4 @ 42'—olo —8" 3063 40134' 5105 7148 BP -5 @ 52 2000 2666 3333 4666 BP -6 @ 57'-4" 1928 2570 3213 4498 BP -7 I @ 66'-0" 864 1152 1440 2015 E r7 O (D N L IO E BLOCKS ARE 202 (NOMINAL) SPF #3 PRESSURE TREATED WOOD (TYPICAL) WITH ME "FDN' GRADE MARK M *\ Esp. SOIL BEARING CAPACITY (8) MAX. PIER CAPACITY (#) �F LENC 1,000 1,875 24 1,000 2.345 30 1,500 3.400 29 2.000 1 4,220 27 2,500 1 5,080 26 -77 MARLETTE HOMES - WOODEN FOOTINGS NOTE: WHERE FON LUMBER IS CUT OR DRILLED AFTER TREATMENT, THE CUT SURFACE SHALLBE FIELD TREATED W1T14 THE FOLLOWING PRESERVATIVES BY REPEATED BRUSHING, DIPPING OR SOAKING UNTIL TI I[ o.. '•': BLOCKS REQUIRED WOOD ABSORBS NO MORE PRESERVATIVE: A ��,,llAA�� PER ARSENATE (ACA), CHROMATEO COPPER ::(:IL BEARING ARSENATE (CCA), FLUOR CHRO?E ARS LY1l7l� ACaMOPPER CHROMATE (ACC) OR I '••''•'•`:ITY GREATER THAN COPPER NAPTHENATE. svldw o ese pans nOI__-p__. c e Fodnrdl Manufaclur v`:-- salbly Standards, FEB 15 200 DO NOT COPY Pepe It the a lusivo 1V0UBLHoM_dtK s oclales, rcf4Erl 405 4%40ar I Unpub I9h(OOD PSF SOIL AND 30" BLOCKS ONLY. SOIL BEARING CAPACITY (#) MAX. PIER CAPACITY BLOCK LENGTH (IN.) 1,000 3,750 24 1,000 4,690 30 1,500 5,625 24 21000 5,760 22 2,500 5,760 21 MAXIMUM PIER SPACING iSOIL BEARING C=, CAPACITY (B) ROOF LIVE LOAD (PSF) 30 40 60 80 120 N 1,000 (24') 2'-8" 2'-4" 2'-0` 1'-B' 1'-4" Md 1,000 (30") S-4" 3'-0" 2'-6' 2'-1' 1'-8" 1,500 4'-10" 4'-4" 3'-7" 3'-1" 2,000 6'-0' 5-4" 4'-6"13'-10" S-0" 2,500' 7'-2" 6--6" 1 5'-5"f4-7'1 S-7' SOIL BEARING CAPACITY ((J) MAX. PIER CAPACITY BLOCK LENGTH (IN.) 1,000 3,750 24 1.000 4,690 30 1,500 6,8_00 29 2,000 8,435 27 2,500 10,155 26 FOR CHASSIS BLOCKING ONLY: (174' SECTION WFTH 12' MAX. SOIL BEARING CAPACITY (# ROOF LIVE LOAD (PSF) 3D 40 60 80 120 1,000 (24") 5'-4" 4'-9" 4'-0' S-5" 2'-8- 1.000 (30") 6'-8` 6'-0" 5'-0' 4'-3" 7-4- 1,500 8'-0" 7'-2" 6'-0' 5'-2" 4'-0- 2,000 8'-0" 7'-4" 6'-1` 15'-3" 4'-1" 2,500 81-0" 7'-4" 6'-1" 5'-3' 4'-1" MAXIMUM PIER SPACING CHASSIS BLOCKING SOIL REARING CAPACITY ((O -'-ROOF LIVE LOAD (PSF) 30 40 60 80 120 11,000 (24") 4'-11' 4'-11' 4'-11' 4'-11' 4'-11" 1,000 (30") 6'-2" 6'-2" 6'-2" 6'-2•" 6'-2' 1,500 8'-07 8'-0" 8'-0" 8'-0" 8'-0" 2,000 W -O" 8'-0" 8'-0" 8'-0' 8'-0' 2,500. 8'-0" 7'-6" 5'-11" 4'-1" PERIMETER BLOCKING SOIL BEARING ROOF LIVE LOAD (PSF) CAPACITY (d) 30 40 60 80 120 1,000 (24')? :5'-9" 4'-7" S-4" 2'-7" 1'-10" 1,000 (30;)■ j7'-2"5'-9' 4'-2" 3'-3" 2'-3" 1,500 8'-0" 8'-0" 6'-1" 4'-9" 3'-3" 7.,000 8'-0" 8'-0" 7'-6" 5'-11" 4'-1" 7,500 8'-0" 8'-0" 8'-0" 7'-1" 11,520 -- SOIL BEARING CAPACITY (#) ROOF LIVE LOAD (PSF) 30 40 50 80 1 120 1,000 (24') 5'-4' 4'-9" 4'-0` S-5" 2'-8- 1,000 (30") 6'-B` 6'-0" 5'-0' 4'-3" S-4- 1,500 8'-0" 8'-0` 7'-3' 6'-2" 4'-10" 2,000 8'-0" 8'-0" 8'-0' 7'-8" 6'-0' 2,500 1 8'-O' B'-0` 8'-0" 1 8'-0" 7'-3" SOIL REARING MAX. Pli.1t BLOCK C ^;,CITY (//) CAPACITY P.� I. -LENGTH 1,000 5,625 24 l,noo - 7,030 i 30 1.500 I 10,19'1 29 :,000 _ 11,52u _ 27 L - -2,'i00 11,520 -- I 26 - FOR CHASSIS AND PERIMETER BLOCKING TOGETHER: (174' SECTION WITH 12' NOVERHANG) _ CHASSIS BLOCKING CHASSIS BLOCKING - CHASSIS BLOCKING SOIL BEARING CAPACITY (#) S''".. !FARING ROOF C. 11'ITY m 30 1.,- .: (24") 8'-0„ (:SD") 8'-0' 0 8'-0" -- 'i00 8'-0" Lt::. LOAD (PSF) 60 80 i 170 40 7-2: 6'-0" 5'-1' 4' 11" '/'-6" 6'-5" 0' 5-0" 0'-0" 8'-0"'+ I_'' o" 8'-0' 2,000 R' -w 8'-o' FOR CHASSIS AND PERIMETER BLOCKING TOGETHER: (174' SECTION WITH 12' NOVERHANG) _ CHASSIS BLOCKING CHASSIS BLOCKING - CHASSIS BLOCKING SOIL BEARING CAPACITY (#) ROOF LIVE LOAD (PSF) 30 40 1 60 80 120 1,000 (24`) W-0" 8'-0" 8'-0" 8-0" 8'-0" 1,000 (30') 8'-o` 8'-o" B-0' 8'-0" 8'-0" 1,500 8'-0" 8'-0" 8'-0" 8'-0" 8'-0" 2,000 8'-0" 8'-0" 8'-0" V-0" W -D" z,spo 8'-0' B' -o" e' -o" B. -O" B' -o" SOIL BEARING CAPACITY (#) ROOF LIVE LOAD (PSF) 3D 40 60 80 120 1.000 (24') 8'-0" 8'-0" 8'-0" B'-0" 8'-0- 1,000 (30") 8'-0" 8'-0" 8'-0" 8'-0" 8'-0- 1.500 B'-0" 0'-0" 8'-0" B' -D" 8'-0' 2,000 W-0" 8'-0" 8'-o" e'-0` e'-0' 2,500 0'-0" o'-0" 8'-0" PERIMETER BLOCKING PERIMETER BLOCKING PERIMETER BI -7f KINC SOIL BEARING CAPACITY (d) SO' 3EARING ROOF I.IVt: LOAD (PSi'1 1,000 (24") Ch.! .:! I (y) 30 An_]_60 80 f 1?0 1.000 (30') .I,).-0. I,:- o (24') 8,-0" 8 -0-1").-0.- 1,500 (30") 8'-0" 8'-U' U'..p• 8'-O" I II' o" (30") 2,000 I.5100 8'-0' 8'-0" Is' -0" 8'-0"' ! U" 8'-0" 8'-0" 2,500 8'-0` 1 If -o" 8'-0';1111'--!1" �'-o" TO FW 8'-0" L,SUO 137:`0'-8'-0"' 8'-0" 8'-0 I L• -0" 8'-0` 0" PERIMETER BLOCKING PERIMETER BLOCKING PERIMETER BI -7f KINC SOIL BEARING CAPACITY (d) ROOF LIVE LOAD (PSF) 30 40 1 60 BO 120 1,000 (24") 8'-0" 6'-0" 6'-B" 5-3" S-8- 1.000 (30') 8'-0" 8'-0" 8'-0" 6'-6" 4'-7- 1,500 8'-0" 8'-0" 8'-0" 7'-10" 5'-6" 2,000 8'-0" 8'-0" 8'-0" 8'-0" 5'-7" 2,500 B'-0` A'-0" 8--0" 1 B'-0" SOIL BEARING RUOF LIVE LOAD (PSF) CAPACITY ((j) 30 40 60 80 120 1,000 (24") 8'-0" 8'-0" 6'-B" 5'-3" 3'-8' 1,000 (30") 8'-0" 13'-0" 8'-0" 6'-6" 4'-7' 1,500 B'-0" 8'-0" 8'-0" 8'-0" 2,000 8'-0" 8'-0" 8'-0" 8'-0" 2,500 8'-0` 1 8'-0" 8'-0" 8'-0" S(I;: r:;:ARING ROOF I.1VF. LOAD (PSF) C:!IACITY (%�) 30 4U fiD 80 i ':?V 1,(000 (24') 8'-0" 6'-0" 8'-0" 7'-10"�';'-6" X00 (30") 8'-0" 8'-0 8'-0" 8'-0" v.,- 10' 1.500 8'-0" 8'-0"I':'-0" 8'-0" FI' 0" 00 8'-0" 8'-0 I L• -0" 8'-0` 0" 2.500 8'-0' B'-0" 8'-0" 8'-0" 11:' 0" 2"x 2'x S/16" STEEL ANGLE CHASSIS FRAME �A (2) REQUIRED 1/4" GRIPPER BASE 3/8" C1,D FLAt r.D GGLT, muT S y"ASHERR COUNTER BORED FLUSH WITH BOTTOM AT 8" O.C. (8) -REQUIRED 1/4" STAND BASE ABE SCO ABS PAD #503 DETAIL "A" oArH 'C" FRAME- ' COACH -J- FRAME 2" CHANNEL -t/4'1/4" GRIPPER 1/4'x1 TEK STS PLATE (4) REQUIRED TEK STS (2) REQUIRED 1/4" GRIPPER 1/2-13UNC-A307 x 4" -- BOLT WITH NUTS (4) REQUIRED 4t 1/2- SCH 40 PIPE RISER WITH /1/2- AOIUSTER HOLES AND 3/8 - THICK TOP PLATE o2" SCH 40 PIPE STAND WITH TWO 01/2- ADJUSTER HOLES ABESCO ABS PAD' 0503 STEEL FRAME SEE DETAIL "A" ILI BASE 10j; n 1/2" A307 BOLT 1/2' A307 BOLT (2) REQUIRED (4) REQUIRED 3/8'x 6'x 6' [T STEEL PLATE 1/2' A307 BOLT C—BEAM J—BEAM (2) REQUIRED ATTACHMENT ATTACHMENT 10.00 O r 01/2"x 3- C.R. LOCK PIN WITH k ft/8' BRIDGE o PIN 49/16 HOLE (TYP) / STAND BASE j TOP VIEW +� 17<at~ TUF-1 'PERMANENT FOUNDATION SYSTEM ABESCO-('US GUARD McANY- 5851 FLORIN - PER -UTS ROAD SACRAI�, CA 45823 PH: (800) 382-8831 FAX: (916) 383-5207 8' 1/2 DIA. HOLE {8) PLACES 1_ S••f—� .3Qv - 1 11 FEEL FRAME TOP VIEW STATE APPROVAL CA 7 U pg�, U - ZI O r v-4 7-3 cm < a WAYNE T. POLVADO, PE—LISTING NO. F94249 SHEET I of 3 P 0 Ln rY v N L9 m N CS) LL) Ln m A w m w Ln N 0 m N 0 GENERAL NOTES GUS GUARD TUF-1 1. DESIGN LOADS: LIVE LOAD - 30 LB. FLOOR LIVE LOAD - 40 PSF WIND LOAD - 80 MPH EXPOSURE 'C' SEISMIC ZONE '4' *SNOW LOAD 100 PSF (SEE NOTE #15) - �— 2. •T}i15-f0 Ni)ATI N SYSt�M li- DE'SIGPIECI.70 ..BE. C014S7`t2(JCTE'C1 OPd A FAIRLY LEVEL SITE WITH NO EXISTING SOIL PROBLEMS. 3. CHASSIS BEAM SUPPORTS SHALL'BE LOCATED AND SIZED FOR THE LOADS AS SHOWN IN THE '1108HE HOME INSTALLATION INSTRUCTIONS'. 4. IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.S.) CAN OCCUR, MANUFACTURED HOME SHALL BE READJUSTED WHEN DS EXCEEDS 1/4", OR WHEN R WILL ADVERSELY AFFECT M081LE HOME UNIT. 5. CARRY ALL FOOTINGS DOWN TO FIRM, UNDISTURBED SOIL FOOTINGS ARE DESIGNED FOR 1.000 PSF TOTAL LOAD SOIL PRESSURE, 'ANO SHALL BE COMPATIBLE WITH LOCAL SOIL CONDITIONS. COMPACTED SAXD MAY BE USED TO FILL IACAL VOIDS UNDER PADS. 6. STRUCTURAL STEEL: FAWCATED ACCORDING TO AISC SPECIFICATION. — ""-- ' INE19 TRODES=37IT-paTE5--Xs i1 A5& BOL75-SAE GR 5 --ASTM A449=ASTM• A3725. 7. THE GUS GUARD ASS BLIES SHOWN ON THIS PACE SHALL BE LISTED AND LABELED BY 8% AND ASSOCIATES FOR THE FOLLOWING LOADS: ALLOWABLE TOADS: HORIZONTAL VERTICAL GUS GUARD TUF-1 22D0# 6000# GUS GUARD MCP PAD 2200#' 6000# GUS GUARD E -Z TIE PAD 22004 6000# B. DURING PRELIMINARY INSPECTION, THE ESTIMATOR SHALL ENSURE MOBILE NOME CHASSIS BEAMS ARE OF STANDARD SECTION =, 16. FOUNDATION BLOCKS 16"1 16'x12" POURED IN PLACE AT GROUND LEVEL MAY BE USED AT INSTALLERS WSCREWR ALTERNATIVE TO PADS. SINGLE VADE COACHES DOUBLE/MULTIPLE COACHES S= 6' MIN. /16' MAX. S= 6MIN. / 21' MAX. YARJIES 10'-70' (SEE TABLE ON SHEET #3) -•• - E— S S---+�—~- - S —moi+ E PADS IN ANY PAIR MAY BE I STANDARD U.N. FOUNDATION - ROTATED 90 DEGREES OR PIERS AS RECOMMENDED BY PVC SERIES OFFSET TO OTHER SIDE TO THE MANUFACTURER OR THE SUPP RT AVOID CLEARANCE PROBLEMS. ENGINEER. TYPICAL THROUGHOUT PAD (TYP) 9. EXISTING COACHES MAY BE RETROFITTED TO kESIST SEISMIC FORCES BY INSTAWNG GUS GUARD TUF-1 UNITS AS SHOWN ON THIS PAGE OF TYPICAL �1�' :``.• 1t F9kNC8A•i1AN• •P4.AN5� .. u u u ❑ ❑ u 15. GUS GUARD TUF-1 FOUNDATION SYSTEM PROVIDES . I n RIDGE BEAM SUPPORT AS REWIRED BY MANUFACTURER E::] (TYPICAL) n ❑ ❑ E] MANUFACTURER OR REPLACE THEM ON A ONE TO SACRAME?dTO, CA 45823 ONE BASIS. El .0 .. ❑_ FAX: (916) 383-5207 8' NOW n a ❑ ,n PADS IN ANY PAIR MAY BE I STANDARD U.N. FOUNDATION - ROTATED 90 DEGREES OR PIERS AS RECOMMENDED BY PVC SERIES OFFSET TO OTHER SIDE TO THE MANUFACTURER OR THE SUPP RT AVOID CLEARANCE PROBLEMS. ENGINEER. TYPICAL THROUGHOUT PAD (TYP) 9. EXISTING COACHES MAY BE RETROFITTED TO kESIST SEISMIC FORCES BY INSTAWNG GUS GUARD TUF-1 UNITS AS SHOWN ON THIS PAGE OF TYPICAL �1�' :``.• 1t F9kNC8A•i1AN• •P4.AN5� .. � y 10. THE GUS GUARD TUF-1 SYSTEMS ARE SAFE FOR INSTALLATION IN FLOOD e� PLAIN AREAS WHERE DEPTH OF FLOODING DOES NOT EXCEED THE HEIGHT =~S OF THREE FEET. 15. GUS GUARD TUF-1 FOUNDATION SYSTEM PROVIDES . I ALLOWABLE SNOW LOAD TO 100 PSF WHEN INSTALLED 11. MULTIPLE LUNrT INSTALLATION IS ACCEPTABLE PROVIDED % c,, THE NUMBER OF TUF-1 UNITS UNDER EACH UNIT IS THE SAME A5 SHOWN REQUIRED PER EACH UNIT. F;•< '�era�''-�.::='= 12. SINGLE-WLDE UNITS REQUIRE ADDTRONAL RESTRAINT. s (SEE SHEET #3)pti; = s� • �'y�' 13. ALL METAL COMPONENTS AND ATTACHMENTS ITCWS SHALL BE PROTECnvE COATED. 14. WHEN CONCRETE SLAB IS IN EXISTANCE, PAD 15 NOT REQUIRED. . ANCHOR STAND TO CONCRETE SLAB WITH T U F -1 PERMANENT FOUR (4) 1/2"x 3 1/2" EXPANSION ANCHORS. FOUNDATION SYSTEM 15. GUS GUARD TUF-1 FOUNDATION SYSTEM PROVIDES ALLOWABLE SNOW LOAD TO 100 PSF WHEN INSTALLED A$ESCO-CM GUARD COMPANY WITH -EXISTING STANDARDS REQUIRED BY COACH 5851 FLORIN "PFRKINS ROAD MANUFACTURER OR REPLACE THEM ON A ONE TO SACRAME?dTO, CA 45823 ONE BASIS. PH: (800) 382-8831 FAX: (916) 383-5207 STATE APPROVAL O i ao » U a <fl `3 _ 1 a o 0 < a g - O J � COD � WAYNE T. POLVADO, PE -LISTING NO. F94249 SHEET 2 cf 3 N d 1/2-x 3 1/2- - EXPANSiON ANCHOR (4) REQUIRED CONCRETE -PAD INSTALLATION CHASSIS FRAME (2) REQUIRED 114- GRIPPER BASE 1/2-131UNC-A307 x 4' BOLT WITH NUTS (4) REQUIRED 01 1/2- SCH 40 PIPE RISER WITH 01/2- ADJUSTER HOLES AND 3/8 - THICK TOP PLATE 02" SCH 40 PIPE STAND WITH TWO 01/2" ADJUSTER HOLES ABESCO ABS PAD X1503 STEEL FRAME--\ ANCHOR BOLT 3/8- CAD PLATED SOLT, NUT & WASHER (4) REOU%RE160 COUNTER BORED FLUSH WITH BOTTOM :69.�ti-x11 -1t� ,tom+�-�- - ��- �• m --,� ���„-_-� - - ♦ Ill POURED IN PLACE 16xl6xl2 CONCRETEu c"1ru�« FOUNDATION INSTALLATION 1 01 /2": LOCK'I 01/8-. PIN , b" MAX eer-Few )F' PAD• • — LIGHT HEAVY—WEIGHT PLASTIC PAD INSTALLATION mmm-w= TT. -M7 lam' -1” to Wl 20 1 20 1 20 1 24 [ [W-1- In aal 10 1 10 1 10 1 10 14i1MBER OF TUF-1 REQUIRED NUMMR OF TUF-I REQUIRED S*iGLE WIDE Ut6TS REQUIRE (4) E -Z 71E PADS. GUS GUARD TUF-1 PIERS ARE TO BE PLACED AT APPROXIMATELY EQUAL RITERVALS ALCM EACH FRAU[,: 2A:i_. TUF-1 PERMANENT FOUNDATION SYSTEM ABESCO-GUS GUARD COMPANY 5851 FLORIN - PERKM ROAD SACRAMENTO, CA 95823 PH: (800) 382-8831 FAX: (916) 383-5207 TATE APPROVAL Lr. N CS) m N m w m Li 01 N CD D m WAYNE T. POLVADO, PE—LISTING NO. F94249 SHEET 3 of 3 w c BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Building) School District G V.,) Y.� ' Building Department No. A.P. Number 63 — / 70' O&Yurisdiction: City County 03 -//7/ - Property Owner / L) r /J Property Location/Address Y' 1,0 A-0 Subdivision ISS1120 .............................................................................................................. Residential Development Sq. Footage cl No of Living Mobile Home Addition/ 'Supplemental to (Group R) Units Installation Conversion Permit # He r4 n P e '(No foundation inspection): Commercial/industrial New Addition Building Dep rtment Representative runs reviewea oy acnooi uismm rersonneo District Identification No. (,/7vu / / U0School District certifies that (Street Address) (City) has complied with the requirements of Resolution No. representing % /lid square feet. School District Representative Paid by Check # Remarks: Sq. Footage (Including Exterior Roofed Areas) Date (Phone Number) (State)/�^/I (Zip Code) ' r,� V� by payment of $ 3/0'76,6 AB 2926 $ FULL MITIGATION $ Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school' district) . feeform.xls (10/98)dmm I ��`�.��� IIIIIIIIIIIIIIII IIII II I IIII II I IIII AND WHEN RECOkDED MAIL TO: Z Q) 10 Z3 —1010 4 8 1 2 el BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE ►� %� Recorded I DEC ORM 11.00 OROVILLE, CA 95965 Official Records I DINFORM 1.00 CountQf I dU rfe:_I CANDACE J. GRUBBS I Recorder I ROSEMARY DICKSON I Assistant I Karen 03:49PM 22 -Jul -2003 I page 1 of 2 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, n^,:sp, and odor. Butte Cnun+,y haE established as :C::ltural purpeses andresidents within said zone -s and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Date N�/�y / 7/ �dQ.3 P OP RTY O RS: To K�► C. t�,,u�y I�GLLIEs f3. P.Lq State of California ) County of QV}-+_- ) ' personally appeared To{nrn C�fr[h s RirP , &a 4d Agnp, Ra)ou 14pdv know*4e4« for proved to me on the basis of satisfactory eviden to be the Person(s) whose to the within instrument and acknowledged to me that JWW/they executed the same in capacity(ies), and that by Jiis/I}ef/their signature(s) on the instrument, the person(s) or the eni the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature 'L Lo"� Seal: A.P. #�(n'� — �G ie(s) 0,are subscribed /their authorized upon behalf of which MICHAEL D. -COLLINS COMM. 01316917 WTARY PMV 1 CALIFORMA BUTTE COUN�2005 MRComm. 6UG. Y. A portion of Section 6, Township 23 North, Range 3 East, M.D.B. & M., more particularly described as follows: Commencing at the South east corner of said Section 6; thence North 0 24115" West along the East line of said Section 6, a distance of 440.42 feet; thence North 73 57' 54" West 295 feet to the point of beginning for the parcel of land described herein; thence South 22 10126" West 529.58 feet to a point on the South line of said Section 6 that bears North 86 17139" West, a distance of 487.14 feet from Southeast corner of said Section 6; thence North 86 17'39" West along the South line of said Section 6, a distance of 268.62 feet; then North 22 10126" East. 587.27 feet to a point at the Southeast corner of that certain parcel of land described in the Deed to K.A. Gaines, et ux; recorded June 18, 1963 in Book 1252 of Official Records, at page 220, thence South 73 57154" East 256.21 feet to the point of beginning. TOGETHER. WITH all the rights of way for road and utility purposes shown in that certain deed recorded in Book 1703 of Official Records, at page 390, records of Butte County, California. AP: 063-170-00.9 BUTTE COUNTY '1�,� , H , AGRICULTURAL BUFFER NOTIFICATION AND/O UNUSUAL CIRCUMSTANCES REQUEST Butte County requires a 300 foot buffer between neighboring agricultural operation nd a residence. This dimension is based on environmental assessments and studies. The Agricultural C missioner may identify unusual circumstances where the 300 foot buffer cannot be met on existing parcels. This exception is not available for lots being created, divided or subdivided. Owner or Authorized Agent must complete the following and return with the required site plan to: Development Services Department, 7 County Center Drive, Oroville, CA (530) 538-7601 Name:- cA ct)G15+TUC4--�6n Phone: E,--,�o gat -3` 5sb Mailing Address: CA.bn iA'fU 00- 9591 E -Mail address c \Non `k2 -('S R @ Sbc(q t A &A Assessor's Parcel Number: Lo � -y-i © - O O 9 Reason you believe you qualify for the unusual circumstances exception: 'M lA a4 -cu r A C S S k_.,,, i horl,w_ ! S LPLr �ih_e 7i om G 7'o GQs f Owner o Auth rized Agent's signature Date UNUSUAL CIRCUMSTANCES DEFINITION: An exceptional or extraordinary condition where the existing lot size or shape or an existing improvement (well, septic systems, structures etc.) does not allow for the standard condition of a 300 -foot buffer zone. SITE PLAN REQUIREMENT: submit 4 copies with this form Refer to the Site Plan Submittal handout for specific requirements ...................................... Internal Dept. Contact Info: ❑ Env. Health ❑ Planning ❑ Building ❑ Other Contact Person: Phone: FORWARD THIS FORM TO LARRY IN DEVELOPMENT SERVICES FOR PROCESSING ......................................................................................................................................................................................... For Agricultural Commissioner office use only: (to be completed after submittal ) DISCRETIONARY PERMITS (Planning) MINISTERIAL PERMITS (Building) ® Exception Recommended ❑ Exception Granted with the ❑ Exception NOT Recommended following conditions: Reason/Conditions/Specific setbacks from adjacent agricultural operations: NO AG. isu_'Tc_'2 1SSUe_ Agricultural Department Signature: 1::::j2 Date: I'MC /03 oco3- no , crag cr (p �rf Cahnt�ed4 t Lzti UQ3 - k -10—M9 I v ironrnentai Nlealii ; APR 2 9 2003 r'hico, Califomia 45, P65,6b �/,W, 0 �?v U 1 o fJ� IZo O(o3- n i EN�jRCWENTA[ HIE40, APR 2 4 ?003 7 CCl1NT 1'Cc,V T DRI VE /cN N APPROVED Butte County Eno e I Heaith e i l S tura r S >r. APPROVED -- Butte County i, Envi I Health te3 i n lure Ila C9 a — ironrnental Heairii ENVIRONMENTAL HEALTH APR 2 4 2003 APR 2 9 2003 �r�ular�rs class rhico, Califomia 7 COUNTY CENTER DRIVE 6'-Ei o wi5zni M7,iaomAo ue IIS% BDRII. D1Nl.YC FAMY ROOM j / 6628-44-2 26'-80 z 66'—T- APPROX. ,1 i ti i9/ If ltiarisscif►�s�i/�tl'fl�l�L-'_.'-f_iti�r'�1/ i%f /''! tJ I LIy(N6 ROOM rr-r' DDR1�.4 ja,- 8D� 3 ppt �rss�� axr� DDm.Z 10'-8' r SITE PLAN REVIEW APPLICATION Date: AP# Permit Number (if applicable) 3 — -7 APPLICANT INFORMATION Parcel Size: A O 7 AL Owners Name: RU C Dom/ d H f Owners Address: e AS T Ave -TI -7 C u 1 G O e-- A 4i S Telephone No.:�1 S— 3 0 �o SNS i _ 82 I — S �j S Q Situs Address: .H 0 1r,) 1 Proposed Use: Residential ❑ New Single Family Residential ❑ Single Family Addition ❑ Single Family Remodel ® Mobile Home ❑ Residential Accessory ❑ Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other ® Septic ' ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necessary): ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) ® Approved ❑ Conditionally Approved ❑ Resolve Problems Prior to Approval JO Site Plan Stamped Approved By - ice' Date Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: N Snow Load Area: - 2dr'G TO 2SOd -�'T — El Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) IM SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: X • Flood Panel No.: L Index Date: ❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mu I berry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance ------------------------------------------------------------------------------------------------------------------- ❑ Detached Building Use Form ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: -'t") — 5 - Applicable Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 Zoning Code Streets & Highways Fire Prevention Subdivision Map Front so c,]-,- ,]LSide Side p 0 Side Street Rear b 3 0 Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 P - Applicable Development Fees: Standard Fees Amount Formula ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area - Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By In Deeds: Date of Creation: 12.-1'1 Legal Access Provided: ❑ No N Yes Deed of Reference: 1 1 - (,1 `7 Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: 0 No ❑ 'Yes, Road Name: Complies with County Standards for Deed Creation:[] No ❑ Yes Comments: Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 Subdivision Map/Parcel Map: Map Date of Recording: Lot: Book: Page: ❑ Use Permit/Minor Use Permit Permit Number: Date of Approval: Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. ❑0 Page 4 of 5 ,F , x a C Summary of Specific Requirements: . This information provided in this summary is based on the application information and on the best available data at the time of review. CAMy Documents\Building Permit Site Plan Reviewl.doc Page 5 of 5 ENCROACHMENT PERMIT County of Butte Department of Public Works 7 Count Center Drive Oroville, CA 95965 Phone (530) 538-7157 Ext. 2016 Fax: (530) 5384356 Download Forms: www.buttecounty.net/publicworks/forms.html NOTIFY COUNTY 24 HOURS BEFORE WORK IS TO BE DONE Phone (530) 538-7157 Ext. 2016 Permit Number District APPLICATION I / WE, the undersigned, hereby apply to the County of Butte for an encroachment permit to do the following work under or over the County roads and highways, all in accordance with County ordinances and general laws. All information except signature must be typed or legibly rinted. 1. Applicant's Name s n ^,..� z.Jr l 1 1 a. Company Name: 2. Address: (og' ( 0 (-(-lea U 5G9 I I. Phone: Cil �c7 Q �j� 4. Assessor's Parcel Number: V 5. Location of Work to be Done 2Ct_n Cly, 6. Applicant's Signature Q 7. Date: _ Q� CONTRACTOR'S INFORMATION 8. Contractor's Name 9. Address 10. Phone: 11. Fax: ��o gay 5�5 12. Contractor's License Number: ' / 1 13. Certificate of Insurance: Yes © No: ❑ 14. Contractor's Signature: 14a. Date Signed: 15. Authorized Agent: TYPE OF WORK TO BE DONE 16. Please Check: Curb: ❑ Gutter: ❑ Sidewalk: ❑ 17. Driveway (List Type): G1 Kl _ ^ 18.Other: PERMIT GRANTED In compliance with the above request, and subject to all terms, conditions (including those on page 2 of this permit form) and special conditions written below, permission is hereby nied. 19. Conditions/ e o e ec/�c! Underground Service Alert .S.A. must be notified two working days prior to any excavation. 800-227-2600 20. ❑ All work shall conform to accompanying: Detail ❑ Plans ❑ Special Conditions ❑ 21. Date Issued 22. Expiration Date: 23 Surety: Mike Crump, Director of Public Works **,.T-- 11-- By: 11VLV. IL perirnts are faxed to any number besides (530) 5384356, they can be delayed up to one week. Page 1 of 2 General Conditions —See Page 2 AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION '7 COUNTY CENTER DRIVE OROVILLE, CA 95965 COPY of Document Recorded 22 -Jul -2003 2003-0048126 Has not been compared vith original BUTTE COUNTY RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte. County has established agricultural purposes and residents within said Zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: Date PtCiLLE5 f3, State of California ) County of AA -Ie- ) personally appeared 06; C o. kAewrt-to-ruer pro oved to me on the basis of satisfactory evidenclto be the person(s) whose to the within instrument and acknowledged to me that XW/they executed the same in capacity(ies), and that byJiisWtheir signatures) on the instrument, the person(s) or the eni the person(s) acted, executed the instrument. WITNESS my hand and official seal. Signature �it `t��c,� A 'L/"01� < Seal: A.P.#COG Ie(s) Ware subscribed OteF/their authorized upon behalf of which MICHAEL D. CO LtINS COMM. N 1316917 No►� � 0 CAUFOMA BUTTE COUNTY Comm. Ex . AUG. 6, 2005 A portion of Section 6, Township 23 North, Range 3 East, M.D.B. & M., more particularly described as follows: Commencing at the South east corner of said Section 6; thence North 0 24'15" West along the East line of said Section 6, a distance of 440.42 feet; thence North 73 57' 54" West 295 feet to the point of beginning for the parcel of land described herein; thence South 22 10126" West 529.58 feet to a point on the South line of said Section 6 that bears North 86 17'39" West, a distance of 487.14 feet from Southeast corner of said Section 6; thence North 86 17139" West along the South line of said Section 6, a distance of 268.62 feet; then North 22 10126" East. 587.27 feet to a point at the Southeast corner of that certain parcel of land described in the Deed to K.A. Gaines, et ux; recorded June 18, 1963 in Book 1252 of Official Records, at page 220, thence South 73 57154" East 256.21 feet to the point of beginning. TOGETHER WITH all the rights of way for road and utility purposes shown in that certain deed recorded in Book 1703 of Official Records, at page 390, records of Butte County, California. AP: 063-170-009