Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
064-180-003
A 1, NOTES H RESIDENTIAL 'x PERMIT NO. __064:180;003 03-0919 .., _. �.,... r..�: h i KETTLE CONST,. ' ,t 1 D(o MASON CT, MAGALIk I NEW SINGLE FAMILY t. 1 1 SPECIAL CONDITIONS CHECKED BY SRA I FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. f is SPECIAL INSPECTION ITEMS VERIFY l` USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER • ,t OFFICE COPY Address GAS DAty� Meter B. ELECRIC Da��-- Meter By t ' t� JOB FINALED (Date) ` O � Signature 0 J=OK 0 = Not OK = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) Date UNDEOPCOOR (Plans) OK excect #'s / <6 "/ tg. in; Soils-Elec. Grnd.-/ /" Ftg. Depth g., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ft , orches & Decks; Soils -Steel-/ /" Ftg. Depth Ste s. Main: Steel- Rlncknuts-Wranneri @@!Hold Downs and Special Anchors 7. Slab Steel -Wrapped ler - e lace Ftg.-Steel .V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF,Qaas'Pipe; Size Anchors -Yard Gas Piping; Size Test-. V. -Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. it rs-Sills-Anchor Bolts-Joists-Vents-Crippies Access & Ventilation 16. Insulation Date 7 // Card B-1 Date Card B-1 Date/ Card B- Date . Card B -1 - Date PLU G.(Permit) OK except #'s 1 r Htr.; Vent -Access -Combustion Air Baffle r Pipe; Test & Anchor -Nail Protection V; Test Fittings & Anchor -Nail Protection Shower Pan; Test, First Floor -Tub Access �� 21. Test -Tub & Shower, Second Floor -Tub Access Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test Date Card B-1 Date Card B-1,-_, Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s Fixture & Transformer Clearance -Ins. Protection ec. Receptacles Spacing -Lights & Switches at Doors Date FRAMINgAPermit) OK except #'s 4d, -,<i s P er Materials & Anchors 4 alts ds -Nailing Spacing & Braces -Plates -Sound 4 arin alts over Girders & Floor Nailing 4 ' aft p in Walls (rat proof) ' S • ps, Furred Ceilings -Stairs -Chasers -Tubs _ 4�.ders & Beams -Size & Bearing Date FRAM!(Continued) Hers -Post Caps -Anchors -Connectors 40'Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. ce ies or Type A Flue -Fireplace Throat Clearance 66!Atti Access; Size & Romex Protection -Draft Stop -Ins. Baffles dr . Windows or Exiting Doors -Sill Ht. mensions 5 . darag€Fire Protection Framing -R annel 53-15roperty Line Firewall & Openings xt cors -One 3' -Check Garage 3rd Story, 2 Exits t `idth-Headroom-Rise-Run-Landing-Fire Protection IyyueotY on Roof Overhang -Attic Vents -Rafter Outriggers 6; -Siding- Nailing Veneer 58. Stucga-Nlesh-Drip Screed -Fd. Vents-Underflr. Access &i lazing Area -Glass Protection -Skylights -Plastic 60. Sjmr Walls; Nailing -Bolts Br Interior/Exterior Wall Panels Ion -Walls -Ceilings @a" -Infiltration -Walls -Windows Date Card Date Card B-1 Date Car Date Card B-1 Date FINA tans) OK except #'s %* E4Steps-Door & Sidelight Protection -Landings Vents -clearance -Comb, Air -Connector - e; Above Floor-Ducts-Mech. Protection 69! & Bath Fixtures & Tub Access -Spa C. Trim & Subpanel, Breaker Sizes & Labels S ' s & Rails place or Stove, Clearance -Hearth EI . Outlets at Wood Panel, Int. & Ext. ixt. & Appliance; Ground -Air -Gap -Cooking Clearance 700" E!W. Outlets & Receptacles at Kit. Counter 7 -Garage Fire Door; Swing -Landing -Closure Duct in Garage -Damper 7 ' tP. r. Htr.; Vents -Clearance -Comb. Air Connector-R.V. ye``arage; Above Floor-Mech. Protection 7r 1b.; Elec. & Mech. Equip. Listed for Location 76' E!gW Receptacles in Garage (F.F.I.)-Romex Protection ation-Foam-Looked in Attic -'"4r 96ard Rails & Deck Construction -Post Caps Fdn. VBents &Crawl Hole Door Drainage & Wood -Earth _Q18arance Looked under.. Floor 0 Yes 8r Following Instlol./Drive O Yes O No/Walks O Yes O No/Planters O Yes O No 'S cc Brown -Finish Unit Disconnect, Electrical -Plumbing 8116'. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings .-83► Wa r Well, Disconnect, Electrical, Plumbing N-Tderior Elec. Trim, G.F.I. Receptacle -Underground K V�tilation Throughout House "'Glass Protection -9- erections from Previous Inspections As Test -Meters Tagged, Gas -Electric a er & Sewer Connected -C/O to Grade -HD Approval 0. ergy Compliance Certificate -Other Certificates . Address Posted @@—Fire Sprinkler Dateto �'L ,03Card B -14T Date Card B-1 Date' Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: maize Boxes & No. of Conductors Stapled •- r�7ex Installed Close to Edge of Studs & C.J. quip. Ground made up w/Mech Fasteners -Bond Gas &•Water e2f-22 . pliance Circuits in Kitchen & Conductor Size GFI _ Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral O Yes Q No 3E.Ice-Riser Conductors & Ground Main Disconnect ' 3$ quip. Clearances Panels-Motors-Mech. Equip. - 41,,Crothes Closet Light -Shower Light -Spa Light - t5.ke Detector Date Card B-1 Date Card B-1 .. •. Date Card B-1 Date Card Date MECHANICAL (Permit) OK except #'s CDucts Insulation & Support $7�/egf Fan, Exhaust above insulation 3 ondansate Drain & Overflow, Size & Grade 29, -Vent Access -Comb. Ait-Return Air Vent 115 Outlet is Access & Platform if Furnace in Attic ._ Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMINgAPermit) OK except #'s 4d, -,<i s P er Materials & Anchors 4 alts ds -Nailing Spacing & Braces -Plates -Sound 4 arin alts over Girders & Floor Nailing 4 ' aft p in Walls (rat proof) ' S • ps, Furred Ceilings -Stairs -Chasers -Tubs _ 4�.ders & Beams -Size & Bearing Date FRAM!(Continued) Hers -Post Caps -Anchors -Connectors 40'Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. ce ies or Type A Flue -Fireplace Throat Clearance 66!Atti Access; Size & Romex Protection -Draft Stop -Ins. Baffles dr . Windows or Exiting Doors -Sill Ht. mensions 5 . darag€Fire Protection Framing -R annel 53-15roperty Line Firewall & Openings xt cors -One 3' -Check Garage 3rd Story, 2 Exits t `idth-Headroom-Rise-Run-Landing-Fire Protection IyyueotY on Roof Overhang -Attic Vents -Rafter Outriggers 6; -Siding- Nailing Veneer 58. Stucga-Nlesh-Drip Screed -Fd. Vents-Underflr. Access &i lazing Area -Glass Protection -Skylights -Plastic 60. Sjmr Walls; Nailing -Bolts Br Interior/Exterior Wall Panels Ion -Walls -Ceilings @a" -Infiltration -Walls -Windows Date Card Date Card B-1 Date Car Date Card B-1 Date FINA tans) OK except #'s %* E4Steps-Door & Sidelight Protection -Landings Vents -clearance -Comb, Air -Connector - e; Above Floor-Ducts-Mech. Protection 69! & Bath Fixtures & Tub Access -Spa C. Trim & Subpanel, Breaker Sizes & Labels S ' s & Rails place or Stove, Clearance -Hearth EI . Outlets at Wood Panel, Int. & Ext. ixt. & Appliance; Ground -Air -Gap -Cooking Clearance 700" E!W. Outlets & Receptacles at Kit. Counter 7 -Garage Fire Door; Swing -Landing -Closure Duct in Garage -Damper 7 ' tP. r. Htr.; Vents -Clearance -Comb. Air Connector-R.V. ye``arage; Above Floor-Mech. Protection 7r 1b.; Elec. & Mech. Equip. Listed for Location 76' E!gW Receptacles in Garage (F.F.I.)-Romex Protection ation-Foam-Looked in Attic -'"4r 96ard Rails & Deck Construction -Post Caps Fdn. VBents &Crawl Hole Door Drainage & Wood -Earth _Q18arance Looked under.. Floor 0 Yes 8r Following Instlol./Drive O Yes O No/Walks O Yes O No/Planters O Yes O No 'S cc Brown -Finish Unit Disconnect, Electrical -Plumbing 8116'. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings .-83► Wa r Well, Disconnect, Electrical, Plumbing N-Tderior Elec. Trim, G.F.I. Receptacle -Underground K V�tilation Throughout House "'Glass Protection -9- erections from Previous Inspections As Test -Meters Tagged, Gas -Electric a er & Sewer Connected -C/O to Grade -HD Approval 0. ergy Compliance Certificate -Other Certificates . Address Posted @@—Fire Sprinkler Dateto �'L ,03Card B -14T Date Card B-1 Date' Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: = QK = Not OK = NotReadyable MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date Card B-1 Date Card B-1 Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s Card B-1 Date Card B-1 Date PERMANENT END SYSTEM (ONLY) 1. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 6. 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged Health Department Approval 9. Exits Plumb.; Cir. Test -Water Supply Test 10. License Decals 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes -Enclosures- Panel boards -Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card 8-1 Date Card B-1 Date Card B-1 Date Card B-1 COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION i !Q 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PV1 (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 064-180-003 ZONING , BU I LD I NG P ER M IT OWNER KETT TELEPHONE 877-0849 SO. FT. OCC. BUILDING VALUATION 1 84 R-" 85 536.00 ' OWNERS MAILING ADDRESS 16 SLOPE OAKS CT. PARADISE 484 U 8,712.00 CONTRACTOR'S NAME OWNER TELEPHONE 1 C 1 456.00 CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ U • UU ARCHITECT OR ENGINEER LICENSE NO. Filen Fee $ 20.00 Permit Fee $ 621.50 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ __AM - X197 BUILDINGjADDRESS,Energy MASON COURT MAGA Plan Checking Fee $ 88.00 MAST- $ PERMIT FEE $ 1,114.47 LOT �"�5 su olvs NS, r�tc�ui`�� PINES X14 38-38/41 PARCEL MAP 7-15-71 PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ff Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 81 7-6056.00. Solar or heat pump water heater 23.00 Water piping 15.00 L5. 00 Each gas water heater or vent 15.00 TYPE OF WORK New M Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: new sr master 01-07 3 brm, 2 bath W/2 Car garage Gas piping system 1- 5 outlets 1 1 5.00 Building sewer 1 15.00 5 . QQ Mobile Home I S I G I W @20.00 PERMIT FEE $ 00 ELECTRICAL PERMIT Filing Fee 20.00 R LESS Main Service A OR LESS 23.00 Z3. 00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. t License Class �.+/.,� i�.¢.00 Lic. No. � is Z � OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service TO 46.00 CCU000A NEW CONST. DWELLING OCCUP. W:O OR ADDNS. ( 6 ACC. S. SO 3.5QFT. 2.24 NON-RESIDT MULTI.OUTLET 97.50 POWER APPARATUS h SINGLE OUTLET CIR. Ex. OCCU OUTLET OR FIXTURES 20®' .� BAL @ .50 Ex. Occup. GFlxuTLEEOTs REFS p) Ea 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 1• MECHANICAL PERMIT Filing Fee 20.00 Heating 1 15.00 Cooling Hood 6.50 Ventilation as s t OVom 1 15.00 1 0( PERMIT FEE $ Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X / Date y��/O $ Signature of Applicant - ❑ Owner I3�%Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep d demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 Occ CONST. TYPE TTAL FEE $ 4,183.2 Irk HAZ. •• p, IMP FLOOD X COS Y/ PARCEL — PO HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. 1, "; By !V t '! �-� t'' Date EXPIRES ON Date —9r3 .01,1tRMIT Receipt No. -5560(10HL e-s WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INS CTOR GOLDENROD -APPLICANT I CertainTeedlml�" � Builders Statement E • Homeowner Name / Jobsith Name InsulSafe 4'. Fiber Glass Blowing, Insulation 4 Inspected By (sign if required) - t - 3 - - - - - - - - - Date R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG MINIMUM WEIGHT- POUNDS PER SQ. FT. MINIMUM THICKNESS To obtain a Thermal Resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag should not cover more than:'(sq. ft.) Weight per sq. fL of installed insulation should not be less than: abs.) Should not be less than: (n.) 60 36.5 27 0.986 22 49 29.6 34 )1 0.800 18'/2, 44 26.4 381i 0.712 163/4 38 22.8 441 - 0.615 •14% 30 18.0 5611 0.485. 12 26 15.5 651. 0.418 10'/2 22 13.1 7611 0.353 9 19 '11.1 90'l 0.301 73/4 13 7.7 129 ! 0.209 51h 11 6.6 151lI 0.179 '43/4 IL THERMAL PERFORMANCE—ATTIC BLOWING APPLICATION ._ 1y • In accordance with the chart above, you must installs;the minimum number of bags per 1,000 sq. ft. of net area for each R -Value listed. • The maximum net coverage must not exceed that specified'for each R -Value. .- • The installed insulation must be at or above the specified minimum thickness for each R -Value. 4. • Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in reduced R -Value. This product should not be mixed with other blown. insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OFA SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. f 30-24-233 Builders Statement A Saint-Gobain Company ©2002 CertainTeed Corporation 11/02 .1 . t ii R -VALUE THICKNESS AREA (SQ. FT) INSULSAFE 4 (✓) BAGS USED BATTS/ROLLS (✓) 1 O " it CEILINGS WALLS t 1 I FLOORS LO I THERMAL PERFORMANCE—ATTIC BLOWING APPLICATION ._ 1y • In accordance with the chart above, you must installs;the minimum number of bags per 1,000 sq. ft. of net area for each R -Value listed. • The maximum net coverage must not exceed that specified'for each R -Value. .- • The installed insulation must be at or above the specified minimum thickness for each R -Value. 4. • Failure to install the required minimum weight per sq. ft. of insulation at or above the minimum thickness will result in reduced R -Value. This product should not be mixed with other blown. insulations or the thermal claims will become invalid. DANGER: RECESSED LIGHT FIXTURES—TO PREVENT OVERHEATING, DO NOT INSULATE ON TOP OR WITHIN 3" OFA SUCH DEVICES. DOES NOT APPLY TO TYPE IC LIGHT FIXTURES OR TO FLUORESCENT FIXTURES WITH THERMALLY PROTECTED BALLASTS. f 30-24-233 Builders Statement A Saint-Gobain Company ©2002 CertainTeed Corporation 11/02 .1 . t Manufacturer Insulation Fact Sheet CertainTeed Cli 0 This is CertainTeed Corporation I nsu Sae 4 Fiber Glass Blowing Insulation 0 CertainTeed Corporation P.O. Box 860 Valley Forge, PA 19482 THERMAL PERFORMANCE—HORIZONTAL OPEN BLOW The following thermal performances are achieved at weights and coverages specified when insulation is installed with pneumatic equipment in a horizontal open blow application: R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG MINIMUM WEIGHT- MINIMUM POUNDS PER SQ. FT. THICKNESS To obtain a Thermal Resistance- - (R) of: Bags per _ 1000 sq. ft. • of net area: - - Contents of bag should not cover 'more than: (sq.ft.)—_— Weight per sq. ft. of Should not be installed insulation should less than: "" not be less than: (lbs.)" -" (m.) ` - 60 36.5 27 0.986 22 49 29.6 34 0.800 18'2 44 26.4 38 0.712 161/4 38 22.8 44 0.615 143/4 30 18.0 56 0.485 12 26 15.5 65 0.418 1072 22 13.1 76 0.353 9 19 11.1 90 0.301 71/4 13 7.7 129 0.209 5'2 11 6.6 151 0.179 R -values are determined in accordance with ASTM C 687 and C 518. Complies with ASTM C 764 as Type 1 insulation. THERMAL PERFORMANCE—SIDEWALL RETROFIT APPLICATION When installed with pneumatic equipment in sidewalls, the following thermal performances are achieved at the thicknesses, weights and coverages specified. R -VALUE BAGS PER 1000 SQ. FT. MAXIMUM SQ. FT. PER BAG MINIMUM WEIGHT- POUNDS PER SQ. FT. MINIMUM THICKNESS To obtain a Thermal Resistance (R) of: Bags per 1000 sq. ft. of net area: Contents of bag should not cover more than: (sq. ft.) Weight per sq. ft. of installed insulation should not be less than: (Ibs.) Should not be less than: (in.) �`�~'•_2^--�� -� - -35°.3' _ - _ -28 '- -- -'_ - _—' 0.967- - _ -•_ - -71/4 22 27.2 37 0.733 5'2 16 19.8 51 0.533 4 15 17.9 56 0.484 31/e 14 17.3 58 0.467 T/2 READ THIS BEFORE YOU BUY What you should know about R -Values. The chart shows the R -Value of this insulation. R means resistance to heat flow. The higher the R - Value, the greater the insulating power. Compare insulation R -Values before you buy. There are other factors to consider. The amount of insulation you need depends mainly on the climate you live in. Also, your fuel savings from insulation will depend upon the climate, the type and size of your house, the amount of insulation already in your house, and your fuel use patterns and family size. If you buy too much insulation, it will cost you more than what you'll save on fuel. To get the marked R -Value, it is essential that this insulation be installed properly. • • Gi COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, Craliforni.a 95965 • Telephone (530) 538-7541 (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 064-180-003 ZONING T- BUILDING PERMIT OWNER KETTLE.877-0849 TELEPHONE SQ. FT. OCC. BUILDING VALUATION 1584 R- 85.536.00 OWNER'S MAIUNG ADDRESS , 16 SLOPE OAKS CT. PARADISE. CA 99969 484 U 8,712.00 CONTRACTOR'S NAME OWNER TELEPHONE 112 C 1. 4 5 6. 0 0 CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 95,704.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 621 5 0 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 4 0 3. 7 9 7 BUILDINWDRESS, MASON COURT MAGALIA,MASTER Energy Plan Checking Fee $ 46.00 $ 23.00 PERMIT FEE $ 1.114.4 7 LA 2�5 UBDNISION'SNAME PARADISE PINES #14 38-38,4117-15-,l PARCEL MAP PLUMBING PERMIT Fling Feel 20.00 Each Trap 8 7-0056 • 00 USEOFSTRUCTURE SF Ci Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat pump water heater 23.00 Water piping 1 15.00 5 • 00 Each as water heater or vent 15.00 5 00 TYPE OF WORK New IR Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: new sr master 01-07• 3 brm, 2 bath w/2 Car garage Gas piping system 1 - 5 outlets 1 • 15.0 0 5•00 Building sewer 1 15.00 5 • 00 Mobile Home I S I G I W 920.00 PERMIT FEE $ 136.00 ELECTRICAL PERMIT Fling Fee 20.00 •00V OR LESS Main Service zo.A OR LESS 23=23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. / ' License Class i4C/�Ci94�: Lic. No. � 2- ZS OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Main Service TO 46.00 Yoo CCU000A NEW CONST. DWFILNG OCCUP. so OR ADONS. ( a ACC. S.3.50FT. 2.24 N.icO DT. MULTI -OUTLET 97,50 POWER APPARATUS a swGLE oLmEr aR. Ex. Occup. OUTLET OR FIXTURES 209''00 BAL Q .SO Ex. Occup. OUTLETS" PERa 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Fling Fee 20.00 Heating 1 115.00 15.0 Cooling 1 15.00 T5.0 Hood 1 6.50 6.50 Ventilation ;z a S S t O V e - 1 15. 0 - PERMIT FEt $ Policy Number (The above sections need not be completed if the permit is for work of a valuation Of one hundred dollars ($100) or less.) I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X Date 3 Signature of Applicant - ❑ Owner Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep d demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ CONST. TYPE T AL FEE $ 4 183.21 HAZ. _ D. F IMP _ FLOOD X CDf V/ ppRC0. _ PD HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. indicated I By A61F Dat ES O�fN 611 t/ ate `^- ReceiptNo. r WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -I CTOR GOL NR D -APPLICANT r E.H. USE ONLY Plot Ran Attached Floor Ran AtUithed ®� .. 919 Seat to TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance r I's 9- L,4 �o5 wss, c�. Dt- Lj -0(9 60 Owner Location AP# . Plan Approved fo • Sewage Disposal, Water Supp y: Public Private Well Clearance for welling. Other �,.(a.-i�.. G� .Qr(4(4& Hold final for: Final clearance O.K. for: NOTE: dD Environmental Health Specialist 8/96 V `Aw"11 iF�ro e.'.a`�e.�Yc.m'`vsix'Hww;W+.'... "` y`4.:� :,.��^, `pf-"`pq�ii'Sy+�,'i4: _ -.....-,yy,'__'..""`".'""'r"'++•i.-+..=.+mit:. COUNTY OF BUTTE-DEPARTMEN-TOI�`DEVELOPMENT. SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95.965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET / ' OWNER: ~Y� ASSESSOR PARCEL NUMBER CY/`7 ( '30 —v�'3 24 63 Proposed Building Use: / Y ' S * F +D k.Q 1 rI -Z&Hunter Technician: V Date: _ Items .equired in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. plans, 3 or 4 sets, signed by the preparer of the plans. 'O'2eomplete plans, 3 or 4 sets, signed by the preparer of the plans. l . 1,,tigineered truss details and layouts in duplicate. No faxes! l g/ Energy compliance design and supporting documentation in duplicate. 6. Manufactured homes: (A) Data sheets and installation instructions, (B) Marriage line information, (C) Floor Plan, (D) Tie down or foundation plans, all in duplicate. "T. Metal buildings: (A) Metal Building Plans, (B) Foundation plans and calculations in triplicate, (C) Elevation views in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be. indexed and returned to the plan review line-up when required items are received. Date'Received By 8.: 'Flood Elevation Certificate, wet -stamped and signed, in duplicate ri 9Plot plan and business license approval from the City of Biggs.... ' El 10. Letter of intent for non-residential buildings ......................... t' ❑ °f=1. Detached Accessory Building Form filled out by the owner..... 12 Hazardous Material Form ............................................... ❑ 13. Other R fining items needed to issue the permit. (May require additional plan review upon receipt of the following items.) Ls as shown on the attached Schedule of Fees Due Sheet ....................................... loi `ement of Intent for Non -heated and A/C Buildings ................................... I itation and plot plan approval from the Environmental Health De a ent in �D =) ❑ 1 Ci of Chico Plumbing permit .............................. .................. alifornia Department of Forestry planar, roval aid. Sent 19. Planning approval for (A) Use: O K (B)Parking: (C) P rcel Check: 4 ._')_ � ontact Land Development about ❑ Improvements, ❑ Drainage ............................... 1. croachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 22. Pre -Inspection for required ................ ;❑ 23. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ . Worker's Compensation Carrier and Policy Number ..............:.............................. 4wowner-Builder Verification (❑ Given to owner, ❑ Mailed to owner) ..................... etter of Signature authorization.................................................................... Recorded copy of Agricultural Acknowledgment Statement .................................... (p / Manufactured home utility clearance................................................................ ❑ 29. Existing violations and/or expired permits......................................................... ❑ 30. ❑ Grant Deed ❑ M . Te/Statement of Facts, ❑ Letter from Legal Owner, ❑ Check to H.C.D. $ ❑ 31. Other: When issued Telep one and hold for pickup. I have been informed of the above items a5d requirements for 49, btaining a building permit. *Pplicant: /` Date: 4-/—/-03 1. Index permit application f' 'onor e bove i m r Plan Check Letter 2. Ad al items requiredI Al c23 I 4o , designer, owner, w ad ised ' ove a by phon ., ap,0 ter, by Date: on ractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: Date: s 'i — O3 Plans approved by: Date: C' to b �l Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Yellow:;Building Division n,r rr� 1 COUNTY OF BUTTE . DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (530) 538-7541 . 1 A SCHEDULE OF FEES DUE OWNER USE N -'S ' F 4-6 � rn CtazEA-k00 B ILDING PERMIT FEES Q alance Due ....................... $ I SI3 -a y A.P. #Gq— /80--QQ3 DATE RECEIPT # DATE REC Additional Fees Due . ................. $ Additional Fees Due ................. $ Revised Plan Checking Fee .............$ SCHOOL DISTRICT FEES ai le'Owwel 11-04 3 K9 {,maid at District Office) (Available after Plan Check) FEES (paid at Building Division) ...................... x$360.00=$ Units Commercial (sq. ft.) ............... x $0.03 = $ % Sq. ft. 4. URBAN AREA FEES (paid at Building Division) Residential ................... —x—=$ # Units Amt. Commercial (sq. ft.) ............ —x—=$ Sq. ft. Amt. 5. RECREATIONAL DISTRICT FEES (paid at District Office) (Available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES 510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK 0. Fq• W • $89.00 (paid at Building Division) 8. WATER TENDER FEES (Battalion # ) $200.00 (paid at Building Division) 9. CSA 87 TRAFFIC FEE $2500.00 (paid at Building Division) 10. OTHER At time of permit application, I was advised the above fees are required to be paid prior to issuance of the building permit. These fees may be changed during the plan checking process. PLICANT DATE " 3 Pursuant to Government Code Section 66020, you are hereby notified that items 2, 3, 4, 5, 6, 7, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original - Buiding Div. 2nd Copy - Applicant 3rd Copy - Owner ' (Rev. 6/00) I I AND WHEN RECORDED MAIL TO: . BUTTE COUNTY BUILDING DIVISION -7 COUNTY CENTER DRIVE ' OROVILLE, CA 95965 kt- COPY of Document Recorded 12 -Jun -2003 2003-0038221 Has not been compared with original BUTTE COUNTY RECORDER -- AGRICULTURAL AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgment to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuitof agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: I Date �Q-�O-O� PROPERTY OWNERS: State of California ) County1 of On before me, personally appeared �9 �d personally - known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s) or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESSm hand and official seal. CHERIHOVEY Signature.A--,Seal: Commission/ 1327113 Notary Public - California Butte County SA.P.ir Comm Expires Oct 27.2005 Im. 11 W041 Preliminary Report Description The land referred to herein is situated in the State of California, County of Butte, and is described as follows: PARCEL I: LOT 275, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "PARADISE PINES UNIT NO. 14", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF 'THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON JULY 15, 1971, IN BOOK 38 OF MAPS, AT PAGES 37, 38, 3940 AND 41. EXCEPTING. THEREFROM ALL MINERALS, OIL, GAS, ASPHALTUM AND OTHER HYDROCARBON SUBSTANCES, WITH PROVISION THAT ANY AND ALL . MINING OPERATIONS SHALL BE DONE FROM ORIFICES OUTSIDE - HE SURFACE AREA OF. THE LAND DESCRIBED HEREIN, AND THAT NO DAMAGE SHALL BE DONE TO SURFACE OF SAID LAND: APN 064-180-003-000 PARCEL II: A NON-EXCLUSIVE EASEMENT OVER LOTS A AND B (THE COMMON AREA) OF SAID PARADISE PINES UNIT' NO. 14, AND THE LOTS DESIGNATED FOR COMMON AND RECREATION AREAS, AS DESCRIBED IN THE DECLARATION OF ANNEXATION FOR UNITS. IV; VI, VIII, X, XI, XII, XIII AND XIV.. r+: ENCROACHMENT PERMIT County of Butte Department of Public Works 7 Count Center Drive Oroville, CA 95965 Phone (530) 538-7157 Ext. 2016 Fax: (530) 538-4356 Download Forms: www.buttecounty.net/publicworks/forms.html NOTIFY COUNTY 24 HOURS BEFORE WORK IS TO BE DONE Permit Number District �� f Phone (530 538-7157 Ext. 2016 030 Ltj 7 E ' APPLICATION I / WE, the undersigned, hereby apply to the County of Butte for an encroachment permit to do the following work under or over the County roads and highways, all in accordance with County ordinances and general laws. All information except signature must be typed or legibly rinted. 1. Applicant's Name: 1 a. Company Name: 2. Address: //ln S��' C'.'i %C 'S �l ,��i G / C 4. Assessor's Parcel Number: 3. Phone: G� 3 7? 08 UGC 5. Location Location of Work to be Done 6. Applicant ign/ C 7. Date: CONTRACTOR'S INFORMATION 8. Contractor's Name 9. Address 0,7 10. Phone: � —7 ,7 ` G� � � c 11. Fax: 12. Contractor's License Number. 13. Certificate of Insurance: Yes El No: El�C�Z 14. Contractor's Signature: _ 14a. Date Signed: 15. Authorized Agent: TYPE OF WORK TO BE DONE 16. Please Check: Curb: ❑ Gum; Sidewalk: ❑ 17. Driveway (List Type): C� L 18. Other. PERMIT GRANTED In compliance with the above request, and subject to all terms, conditions (including those on page 2 of this permit form) and special conditions written below, enmssion is hereby ted. 19. Conditions P% �� O r t L YY1 'CYC Pr e—�� (1 �, o ¢ t C—. v.� -C Go -4S —C (L�► �T t E otJ-V ever' Tv O t S Gil S 3 3 55--�5358-14-0(0 Underground Service Alert .S.A. must be notified two working days prior to any excavation. 800-227-2600 20. 0 All work shall conform to accompanying: Detail K Plans ❑ Special Conditions 21. Date Issued 7/ 22. Expiration Date: t G O y 23 Surety. tS Mike Crump, Director of Public Works BY: e—a,4��t **Note: If permits are faxed to any number besides (530) 538-4356, they can be delayed up to one eek. General Conditions — See Page 2 Page 1 of 2 OR GENERAL CONDITIONS 1. It is understood and agreed that the County has prior right to the use of its rights of way. It is further understood and agreed by the Permittee that the doing of any work under this permit shall constitute an acceptance of all the provisions contained herein and failure on the Permittee's part to comply with any provision will be cause for revocation of this permit Except as otherwise provided for public agencies and franchise holders, this permit is revocable at any time. This permit is to be on job at all times while the work is being done. 2. All work shall be done subject to the supervision of and to the satisfaction of the Public Works Department of the County of Butte. The Permittee shall, at all times, during the progress of the work, keep the County Highway in as neat and clean a condition as is possible and upon completion of the work granted herein, shall leave the County Highway in a thoroughly neat, dean, and usable condition. 3. The Permittee agrees by the acceptance of this permit to properly maintain any encroachment placed by the Permittee on any pad of the County Highway and to immediately repair any injury to any portion of the highway, which occurs as a result of the encroachment, until such time as the Permittee may be relieved of the responsibility of such encroachment by the County Department of Public Works. 4. It is further agreed by the Permittee that whenever construction, reconstruction, or maintenance work upon the highway may require the installation provided herein shall, upon request of the County Department of Public Works, be immediately moved by and at the sole expense of the Permittee. 5. No material used for fill or backfill in the construction of the encroachment shall be borrowed or taken from within the County right of way. 6. At least one lane of any public road, under the jurisdiction of the Board of Supervisors of Butte County, and other public roads junctioning or intersecting therewith, shall be kept open for travel by the general public at all times. No public road under the jurisdiction of the Board shall be dosed to travel by the general public without special permission, in writing, from the Board of Supervisors. 7. The Permittee, by the acoeptanoe of this permit, shall assume full responsibility for all liability for personal injury or damage to property which may arise out of the work herein permitted or which may arise out of the failure on the part of the Permittee to do the work provided for under this permit In the event any claim of such liability is made against the County of Butte or any department, official, or employee thereof, the Permittee shall defend, indemnify, and hold them and each of them harmless for such claim, 8. All excavations shall be backfilled and compacted immediately after work therein has been completed. Trenches shall not be left open farther than 300 feet in advance of pipe laying operations or 200 feet to the rear thereof, unless otherwise permitted by the Engineer. Unless otherwise permitted under the Special Conditions, backfill shall be place and mechanically compacted in such a manner that the relative compaction throughout the entire fill within the County road right of way shall conform to the percentage of compaction as stated below. Permittee shall notify foreman 24 hours before backfilling and/or paving. a The relative compaction from the bottom of excavation to a plane five feet (6) below finish surface grades shall be no less than ninety percent (90%) as determined by Test Method No. Calif. 216•C of the Materials and Research department State of Ga!rfom!=, Tn_ns� taticn Department, Division of Highways, or other approved test method. b. The relative compaction from a plane five feet (5) below the finish surface grade to said finish surface grad shall be no less than ninety-five percent (95%) as determined by the above testing method. Permittee shall bear all costs and responsibility for compaction tests. a The relative compaction from a plane five feet (51 below the finish surface grade to said finish surface grad shall be no less than ninety-five percent (95%) as determined by the above testing method. Permittee shall bear all costs and responsibility for compaction tests. Material for use as trench backfill in any existing or proposed roadway section shall be sand, shall be place in 8" lifts, and be compacted to a relative compaction of not less than 95%. Material for use as backfill in roadside gutter excavations shall be the native material and be compacted to a relative compaction of not less than 90%. Any pavement cutting shall be scored, or saw out before trenching. NGnimum depth of cover over all underground facilities shall be 30 inches, except drainage culverts. ` All installations, parallel with roadway, shall be placed as dose to the right-cf--way line as possible. No portion of the backfill(s) shall be compacted by ponding or jetting.. All pavements, curbs, gutters, lsidewalk! , borrow ditches, 'pipes, headwalls, road signs, trees, shrubbery, and/or other permanent road facilities impaired by or as a result of construction operations at the construction site(s); or at other grounds) occupied by materials and/or equipment, shall be restored immediately upon backfilling or the excavation to the original grades and cross sections, and to a'condition as good as, or better than, existed prior to the construction. All surfacing materials of roadways and driveway approaches cut or damaged by or as a result of construction operations, shall be replaced within ONE WEEK following the backfilling of excavation, weather permitting, with compacted layers of surfacing materials at least as thick as the existing, and no less than two inches (2') of asphalt concrete over eight inches (8") of aggregate base, according to current California State Specifications. 9. Whenever necessary to secure permission from abutting property owners, such authority must be secured by the Permittee prior to starting work. . 10. The future safety and convenience of the traveling public shall be given every consideration in the location and type of construction. Permittee shall cause to be placed, erected, and maintained all warning signals, lights, barricades, signs, and other devices or measures essential to safeguard travel by the general public over and at the site of work authorized herein. 11. If the construction work covered by this permit is to be done by a private contractor hired by the applicant, applicant shall notify contractor as to the special conditions and requirements contained herein. Page 2 of 2 ,.00ATION: e,/0Gy A/7aso17 Cf DATE: `r / O 2- /0 3 FOREMAN: ► yg n k ee MIN. DISTANCE: DISTRICT: PERMIT#: SPEED LVAIT OF` ROADWAY, o DRIVEWAY LOCATION: .c � DISTANCE TO NEAREST INTERSECTION: SIGHT DISTANCE OOD --O-POOR IF POOR - RECOMMENDATION TO IMPROVE: O CUT BANK O REMOVE VEGETATION (TEMPORARY) ❑ OTHER (EXPLAIN) ADJACENT TOPO - LAT ❑' CUT SLOPE FT. ❑ Fel SLOPE FT. AND GUTTER_ ❑ AC DIKE ❑ EXIST. DIST, I TO EP FT. DRAINAGE RECOMMENDATIONS ❑ NONE SwALE CULVERT MIN. DIST. FT. EDGE OF EXISTING PAVEMENT (EP) 1 —----------- ��. z Li J 12' MIN. ]\\AREA 20' MAX. TO BE PAVED R/W 1 10' MIN, .NOTE: IF GREATER THAN 107o UP' OR DOWN REFER. TO ENGINEERING. MAX. 1 FOOT VERT. RISE OR DROP PER 10 FEET HORIZ. DISTANCE MIN. DEPTH TO t FT. EP DIAMETER \-;L— IN. LENGTH a -,o FT. EXIST. DIST. I MIN. I I I O OTHER (EXPLAIN) 2y, DIST. NOTE: PAVEMENT TO EXTEND AT 29 CROSS SLOPE OR MATCH • EXISTING ROADWAY CROSS SLOPE. MIN. DEPTH KT.& t PRIVATE DRIVEWAY FIELD REVIEW 00,MWeer 4 uT u BUTTE -COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One form per Bullding) School District Qn f a �Q g y Building Department No. A.P. Number ��%� �QQ — Q p �j Jurisdiction: �, Clty County Property Owner t + i (Y ! .v S t i u e- ` - % D .4/ Property Location/Address ► v ► G 5 r)A/ ,L 10 G Q Ge (► 4 Subdivision Pf, e 4, 41 ; e5.0 i A e- S dk 14 Lot No. Residential Development .................................................................................................................. $ Sq. Footage rj No of Living Mobile Home Addition/ 'Supplemental to (Group R) Units Installation Conversion Permit;# '(No foundation inspection). Commercial/Industrial Sq. Footage New Addition (Including Exterior Roofed Areas) �//�� 4,—L1—d�i Building Department Representative Date imoor clans reviewed by School Uistnct Personnel) District Identification No. " % 3 zza- chool Distnct certrfies that (Applicant) (Street dress) v G (Phone Number) (Gty) (State) (Zip Code) has complied with the requirements of Resolution No. representing / square feet. School District Paid by Check # Remarks: by payment of $ 3 3 ( 9 �/j Date Notice: You may protest the imposition of.the fees identified above by submitting a written protest to the District, in compliance with Government Code Secti6n'66020(a),, within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit . you from °challenging the imposition of the fees in any court action. t, If, subsequent to the School District Representative signing this Butte'County.Schools Impact Fee Certification form, the School District is i 'notified by the applicable Local Planning Agency that this project is be(ng reviewed under the California Environmental Quality Act (CEQA), `r this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls 110/98)dmm AB 2926 $ FULL MITIGATION $ Date Notice: You may protest the imposition of.the fees identified above by submitting a written protest to the District, in compliance with Government Code Secti6n'66020(a),, within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit . you from °challenging the imposition of the fees in any court action. t, If, subsequent to the School District Representative signing this Butte'County.Schools Impact Fee Certification form, the School District is i 'notified by the applicable Local Planning Agency that this project is be(ng reviewed under the California Environmental Quality Act (CEQA), `r this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xls 110/98)dmm - OdTt�r Inter=Departemorandum 0 0 aunt; TO: F ROM: SUBJECT: DATE: :b�� o3-o5iq �bLe,#4- pe 4-pe e '3 ol/ell— %u55 82- :-•y •'auk �s '3 ol/ell— %u55 82- Other Septic ❑ Well ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necess ._ h1 D• I f' �/ p PPL -7 Cpr ri &-p DO NOT WRITE BELOW THIS LINE DEVELOPMENT SER VICES INFORMATION (For Staff Use) ❑ Approved Conditionally Approved ❑ Resolve Problems Prior to Approval Site Plan Stamped Approved •BY Date Page 1 of 5 ` - SITE PLAN REVIEW APPLICATION Date: 2- U —U J AP# . Permit Number (if applicable) APPLICANTINFORMATION Parcel Size: Owners Name: Owners Address: Telephone No.: • Situs Address: t-0 7-1 Proposed Use: G� - New Vesitial Single Family Residential ❑ Single Family Addition ❑ Mobile Home ❑ Single Family Remodel ❑ Residential Accessory ❑ Permanent Second Dwelling E]Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family • Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Commercial Remodel ❑ Industrial Addition ❑ Industrial Remodel Other Septic ❑ Well ❑ Agricultural Exempt Building ❑ Other: Brief Explanation (if necess ._ h1 D• I f' �/ p PPL -7 Cpr ri &-p DO NOT WRITE BELOW THIS LINE DEVELOPMENT SER VICES INFORMATION (For Staff Use) ❑ Approved Conditionally Approved ❑ Resolve Problems Prior to Approval Site Plan Stamped Approved •BY Date Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: • Snow Load Area: CF -C) -F-l" ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) P SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: x • Flood Panel No.: O 4 ED Index Date: 6_8_98 ❑ -Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) E] North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading' Zone (See attached handout) Use Requires: • ❑ Use Permit ❑ Minor Use Permit El *Minor Variance E] Administrative Permit ❑ Variance ❑ Detached Building Use Form ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: 1� r� U Applicable Building Setbacks: Zoning Code Streets & Highways Fire Prevention Subdivision Map Front Side 5 3 � Side Street Rear I S- 3� Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 f' Applicable Development Fees: Standard Fees Amount Formula ❑ Fire • ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 El Chico Urban Area — Road ❑ Thermalito Impact ❑ Other --------------------------------------------------------------------------------- Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By • ❑ Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly'Maintained Road: Complies with CountyStandards for Deed Creation': ❑ No No ❑ Yes, Road Name: ❑ ❑Yes Comments: ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑Provide Deed of Creation ❑ Obtain a Certificate of Compliance , ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone J] Meet current Environmental Health Department requirements -------------------------------------------------------------- Page 3, of 5 UN Subdivision Map/Parcel Mao: fip, Map Date of Recording:' -7 - 7 • Lot:., Book: � ❑ Use Permit/Minor Use Permit Page: �> (S q 1 Permit Number: Date of Approval: Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NEPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land 'disturbance. The Erosion Control Plan • must be prepared by a registered civil engineer or other qualifiedrofessional submitted to and approved by the Department of Public Works. p and be ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. PP pnate ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services', Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for roa • ❑ • Page 4 of 5 • • M Summary of Specific Requirements: This information provided in this summary is based on the application information and on the best available data at the time of review. C:U.arrys\i3uilding Permit site plan Reviewl.doc r ' Page 5 of 5 i g4- lid "°uj o 3 National Pollutant Discharge Elimination System (NPDES) Phase II asp Construction Stormwater Permit and Storm Water Pollution Prevention Plan(SWPPP)Acknowledgement BUTTE gemenCOUNTY JUN 19 2003 Project Title: CAJ /V%/�SD/U - DEVELOPMENT SERVICES By signing below, I, the project owner/owner's agent, -certify that I am aware that a construction project that disturbs more than 1 acre of land requires a Construction Storm Water Permit from ,;the State Water Resources Control Board and that itis my responsibility to submit a Notice of 'Intent (N.O.I.), a Storm Water Pollution Prevention Plan (SWPPP) and a check for $700.00 made payable to the State Water Resources Control Board to obtain such a permit if my project Cdisturbs more than 1 acre of land. I, further, certify that this project will not disturb more than 1 acre of land... I am aware that submitting false and/or inaccurate information may result in t revocation of grading and/or other permits or other sanctions provides by law. Signed: Title: Date: National Pollutant Discharge Elimination System (NPDES) Phase II Construction Stormwater Permit-and-Storm-Water-Pollution-- ' •f•• Prevention Plan (SWPPP) Acknowledgement a Project Title:Si,�,vLE ps1J /�9,/fsv e% By signing below, I, the project owner/owner's agent, certify that I am aware that a construction ' project that disturbs more than 1 acre of land requires a Construction Storm Water Permit from the State Water.Resources Control Board and that it is.my responsibility to submit a Notice of Intent (N. .1.), a Storm Water Pollution Prevention Plan (SWPPP) and a check for $700.00 made payable to the State Water Resources Control Board to obtain such a permit if my project - disturbs more than 1 acre of land. I, further, certify that this project will not disturb more than 1 acre of land. I am aware that submitting false and/or inaccurate information may result in revocation of grading and/or other permits or other sanctions provides by law. Signed: Title: Date: NPDES & SWPPP Non -Compliance Certification Butte County Storm Water Management Plan Revised 5/22/03 ' r,• Kettle Construction � � � ..' .. Qhris Kiki'le >q.116 Slope Oaks Ct. ,\`,L ` ' C.q - Paradise CA 95969 r„ �• --�` a 19 JUN � Ol �. _ f -41. �I c\\ CA . `111'irtilt'I'tltj61, 1"itJt1IItill ti1111t1.11tltrt 1111 lt�tt�'fif:tl 1 I i i 111 Ii li If 1; H 1lii i i li Ili 11 Ili lliii li i :rl a D Feb 01\`02 08: 13a P. 1'. COUNTY OF BUTTE - DEPARTMENT' OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville, California 95965 - Telephone (5 0) 538-7541 3- p R 1 No. tRev.12/961. APPLICATION AND PERMIT �j I ASSESSOn `""�t� j Z°" _ BUILDING PERMIT OWNER J `fr �ONE 1<' TEL SO. FT. I OCC. BUILDING VALUATION CONTRACTORS MARINO ADDRESS CONSTRUCTION LENDER LENDER'S MAILING ADDRESS ARCHITECT OR ENGINEER ARCMTECT OR ENGINEERS MAVNG ADDRESS sunowo AooREss / i - LOT NC2 / SUBDIVISIONS NAME USEOFSTRUCTURE '� 1 SF,K Duplex ❑ Mobilehome ❑ Other 6P Miry TYPE OF WORK New X Addition ❑ Ryemm�od,ell �❑-p�U�tilities ❑ Installation ❑ Other ❑ Describe ^Work: I e l C2(1XSt/l,�St �, t� rnaota,� xa 20� -rtD 2Sd'a_�T f Ljm"D� t �C 1 D L-1 ory e-6— "PER UT FEE PAM S_ 5� SRA 00 SHERIFF OTHER AMOVNT aEcWnb *arice:►r:'xi�e: ✓��J� To Ie rvi:niio COMM "EI aQ.�x-,Q.- 9 55 .a 4 a-> C6 Fire lace I 1 `f -7 o Total Valuation $ _(fib Fling Fee 1 $ 20.00 Permit Fee $ r,� • Energy Plan Checking Fee $, z0 p t.00 DAL .SO EY. OCCU PERMIT FEE $ $ -017) ` PLUMBING PERMIT sPiling Feel 20.00 Each Trap Misc. Wiring 7.00 56.00 23.00 Solar or heat pump water heater 23.00 Water piping 15.00 5,00 Each gas water heater or vent 15.00 i'SrO1b Gas piping system 1 - 5 outlets15.00 13 .V0 Building sewer ( 15.0015•(70 Mobile Home S G W 1 920.00 PERMIT FEE $ 00 ELECTRICAL PERMIT Fling Fee 20.00 Main Service OOooA oR OV OR LESS LESS a ] 23.00-.7W 2 OD Main Service 200A TO t000A 46.00 NGW CONST,OWELLINO OGCUP. OR ADONS. & ACC. DLDs. 3.5QFT, , Qj Ntw V9145IMULTI•°UTLET NON•Resa BRANCH CIRCUITS I _ EX. Occup.. ounEr OR FOLTUREs z0 p t.00 DAL .SO EY. OCCU FIXED APPLNS. OR OUTt.m (RES10.1 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE i I 16, a MECHANICAL PERMIT Fling Fee 20.00 ting Lo lin 1S'(70 d 6.50 yC 1 S 10 115100 PERMIT FEE S ,'j Mobile Home Installation Fee $ Energy Inspection Fee b4(alO CTYYPPEES TI�AOTL FEE $ CDF This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work Indicated above for which fees have been -paid. By Date Receipt No. PERMIT EXPIRES ON - WHITE •D.O.S.•B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD•APPLICANT ere -- :�. ��, ,�. „ � r, ;�i. r • y CDF FIRE SAFE REQUIREMENTS _f00 -U3 4 3 � m1 AP# PERMIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made apart of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. 1272.00 Maintenance of Defensible Space. To ensure continued I maintenance of properties in conformance with these standards and measures and to assure continued avail- ability, access and utilization of the defensible space provided for in these standards, annual maintenance must be provide for by the land owner. Driveway Standards 1273.02 Surface. All driveway surfaces and structures (bridges, 1273.07 culverts and other apparteaant structures which supple- ment the roadway bed or shoulders) shall provide unob- structed access to conventional drive vehicles, includ- ing sedans and fire apparatus weighing up to 40,000 pounds. [�l 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius 1. No roadway shall have a horizontal inside radius of, curvature of less than 50 feet and additional sur- face width of 4 feet shall be added to curves of 50- 100 feet radius; 2 feet to those from 100-200 feet. l 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [�] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [�] 1273.05 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [�] 1270.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of 3: 6 0�'6m� (_< 'ff 7tLe� 'L/ AP ## PERMIT # NAME 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [ 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates [�[] 1. Gate entrances shall be at least two feet wider than the roadway it serves. [� 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [� 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. . Fuel Modification 1276.01 Setback for Structure Defensible Space. [ ] 1. All parcels 1 acre and larger shall provide a mini- mum 30 foot setback for buildings and accessory buildings from all property lines and/or the center of the road. 2. For parcels less than l acre, local jurisdiction shall provide for the same practical effect. See Other Requirements below. [ 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction )r fi_%al inspection of a building permit. Page 2 of 3 lv e/'r 3 D 3 AP ## PERMIT NAME Other Requirements [ ] If Building Setback is 15 to 30 Feet: - Class A or B roof - Enclosed eaves [] If Building Setback -is -Less Than 15 Feet Choose any 3 of the following: - Metal or no doors on side toward property line with insuffi- cient setback - Class A or B roof with enclosed eaves - Interior automatic sprinkler system per NFPA 13D - Glass area not to exceed i0t of wall area toward property line with insufficient setback f - Siding from the following list: Stucco - 3 coat Hardi-Board or Plank Masonry 1 Masonry veneer j Metal Other Butte County Fire Department approved materials i ��3,oma Date Signature Page 3 of 3 n Q z �v n r r � C Jz 71 i 4 1� w � V y y R.�^Aapd s4.�t�#�&VKy�?yMifi p�ps�f',ttr��y,.rq� w,,wd^�1��•.id' rn 1 i tt� ? Q � (3 01 > 0.1 l < r co --� - �!El Nco n -lull < d o co C C�cC c2 m .m r!3 m> " co �©m omo rn G o -n S w co coz r ci rp 0 m me v i; • F�1 4� "1 .{r i; • F�1 "1 I •4