Loading...
HomeMy WebLinkAbout064-220-035r c O :f�s _ 064-220-035 PERMITN94-2501 MALLORY, BRIAN DANA CT., MAGALIA NEW SINGLE FAMILY + 11 RESIDENTIAL ' 064-220-035 — LPERMIT#94-2501 MALLORY , . BRIAN 61.1,1—DANA CT., MAGALIA NEW SINGLE FAMILY P� 2s e� y d �i w\ske w- ' iOFFIC ppy � Address GAS Meter By Date f ELECTRIC Meter By (Q Date' I• �bFFICE COPY Address V _ GAS Date1�� Meter By ELECTRIC .. DaTe j Meter By _ _ J � � y `JOB FINALED (Date) J Signature l V=OK O=Not OK - = Not Applicable = Not Ready RESIDENTIAL (Single & Duplex) 2. Ftg., Main; §9K-Elec. Grft0 =/ P' Ftg. Depth 3. Fta., G ae; Spif�Steel-SteelGrnd. / /" Fta. Depth 4. Ftg. s & Decks; Soils -Steel-/ /Ftg. Depth 6 to s, Main; Steel -Blcckouts-Wrapped ?!Slab; Steel -Wrapped 8. Piers-Jceplace Ftg.-St /0-1-7-91 .V.; Fell -FI -fh1T-_2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Materiel -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date/Initials PLUMBING Permit OK except #'s 16. Water Htr.• ent- cces_s-Combustion r -Baffle 17. Water Pipe; nc rotection D.W.1k; Test -Fitts & A�-Nail Protection 19rSrt10 r Pan; Test, Fi s Floor -Tub Access 20r_Te0-Tru'b & Shower, Second Floor -Tub Access 2 . Gas Pipe; Size & Anchors j2 Date/initials ELEC AL (Permit) OK except #'s Fixture,& Transformer Clearance -Ins. Protection at Doors Installed Close to 26. Equi round made up w/Meth. Fastners-Bon as & We r Vel -Appliance Circuts in Kitchen & Conductor Size/GFI 28. ga. Cu or AI-A.C. Wire Size ange C'rc. / g . C or AI -Oven Circ. / / ga. C I. 1 ated Neutral ❑ Yes 3U. ice:Riser Conductors & Ground -Mein Disconnect 31. Egal'p. Clearances Panels -Motors -Mach. Equip. Light Detector Date/Initials MEC CAL Permit OK exce t 's A.0 ucts Insulation port 3 ent�an, Exhaust above insulation 3 nden rein & Overflow; Aerl Grade 37. Furwce ent;lkccess-Comb. Air -Return Air Vent -115 outlet ttic Access & Platform if Furnance in Attic Material & Anchors 40. War Studs -Nailing, Spacing Brac Isles -Sound 4I-lfeaong Wells over Girders & Floor Neillna 1t Stop in Walls (rat proof) 43. Fire,96'ps; Furred Ceilings -St ses-Tub [fate/Initials FRAMING (Continued) 45. Hangers -Post Caps_-Antiiors-Connectors 46. Cing. Joist-Rimes-Purlin=roof Bmc-Truss-Shthng.-Rfng. ype A F ue- nce is Access; SIzejl,,Romex Protection -D ft Stop -Ina. 13affles 49. Bd in or Exiting Doors- gt. &bWmrff9Tons erage Fire Protection Framing 51. Pro a Firewall & Openings 52. Ex( Doo ne 3' -Check Garage -3rd Story, 2 Exits 53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 54. plywo d on Roof Overhang -Attic Vents -Rafter Outriggers 96- ilin eneer 56. Stucc -Drip Screed -Fd. Vents-qpderfir. Access 5 .. lazing Area -Glass Protecti ylights-Plastic 58 She ells; Nailing -Bolts % Insulation -Walls -Ceilings X60. Infiltration -Walls -Windows Date/Initials FINA lana OK except #'a Ex reps -Door & Sidelight Protection -Landings moke Detector 8 Furnac Vents -Clearance -Comb. Air -Connector - n erage; Above Floor -Ducts -Mach. Protection 4. droom Exiting . & Bath F ea & Tub Ac & s -Sp Elec. Trim & Subpanel; Br er Sizes & Labels 7tYl�N' .Fixt. & Appliance; Grnd--AtfGap-Cookf9Clearance at Kit. Counter Fi re "r. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Ga ; Above Floor -Mach. Protection 7 I ec. & Mach. Equip. Listed for LocgWn 30"-Elec. Receptacles in Garage; (G. .. -Romex Protection nsulotion -Foam-Looked in Attic ❑ Yes IV'fdn Vents & Crawl Hole Door -Drainage Vaad-Earth CI ance Looked under Floges Following instld.; Drive ❑ No; Walks es ❑ No; Planters ❑ Yes o 62 A. nit; Disconnect, Electrical, Plumbing 8WOVents Above Roof; Plbg.-Appliance-Fhepfee"learence to SAOWgfer Well; Disconnect, ElecLrfEl, Plumbina @Sf tx Elec. Trim; G:1"(. Receptacle -Underground 86!Ve7hroughout House J_Q.gq 89. Gas TiW-Vetea�aaaed: Gas -Electric 4/f 90. Water & Sewer Connected -C/O to Grade -HD Approval rfff'JoEnergy Compliance Certificate -Other Certificates 7 Comments at Flnal: -9 -qy V= OK O=Not OK Not Applicable Not Ready MOBILE HOMES ' = Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -fall -C/O Concrete 4. Water; Location -Test -Easement Needed (Sketch) S. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /" L"ft. / /"Nat. or/ /'L"ft./ P'LPG 7. Well Clearance & Disconnect 8. Utility Clearance Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'a 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3.. Gas; MH Teat -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances S. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch _ 10. Cert. of Occupancy MISCELLANEOUS Date/initial DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs: Connectors Shthg: Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Truases 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date/Initials POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.;Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures-Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test COUNTY OF BUTTE - DEPARTMENT OF DEVIELOPMW SERVICES - BUILDING DIVISION 7 County Center Drive . Oroville, California 95965 - Telephone (916) 538-7541PFIIMIT Np 1 s � APPLICATION AND PERMIT ��-OLS / "1 ASSESSOR PARCEL NUMBER 064-220-035 ZONING - RT -1 BUILDING PERMIT OWNER BRIAN MALLORY 873- 1355 SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS1419 PO BOX 1363 MAGALIA, 95956 R 76 410.00 400 M 200.00 7,- CONTRACTOR'S NAME OWNER TELEPHONE CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ LENDER'S MAILING ADDRESS Filing Fee $ 20.00 Permit Fee $ 567-50 ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 368 90 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ Penalty $ BUILDING ADDRESSPERMIT Z 2 DANA COURT FEE $ MAGALIA PLUMBING PERMIT Filing Fee 20.00 Each Trap 7.00 Solar or heat pump water heater 23.00 LOT NO. 116 SUBDIVISION'S NAME PARADISE 11R PINES #14 PARCEL MAP 38-38/39 Water piping 15.00 Each gas water heater or vent 15.00 15 nn USE OF STRUCTURE SFX Duplex ❑ Mobilehome ❑ Other SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home S G I W @20.00 TYPE OF WORK New q(XAddition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: SF 3 BEDROOM PERMIT FEE $ 136 00 Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service ( '" OR LIES ) 200A OR LESS 23.00 Main Service ( 200A TO 1000A ) 46.00 NEW CONST. DWELLING OCCUP. OR ADONS. ( H. ACC. BLDS. ) gD, 3.5C Fr. CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one) I am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force aAd effect. License No. �Zg 7 %Z Classification js ❑ I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) O I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) ❑ 1 am exempt under Sec. Business and Professions Code forthis reason NEW CONST. MULTI -OUTLET -NON-RESID. I BRANCH CIRCUITS ) @7.50 ( POWER APPARATUS ) & SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 @ 1.00 BAL. .50 FIXED APPLNS. OR Ex. Occup. ( OUTLETS IRESID.1 EA. ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. g1 shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 106.50 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating SPLIT SYSTEM 1 15.00 Cooling 3 TON 15.0 Hood 6.50 6, 5 Ventilation 2 4.50 9.00 PERMIT FEE $ 65 .50 Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in consequence of the granting of this permit. c, Date �'7- l Sig ature of Applic-Mowner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. j /By4 Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 occ CONST. TYPE TOTAL FEE $ J I HAZ. I D. FEE IMP I FLOOD I CDF X PARCEL PD __ HD SSUE This permit is hereby issued under the applicable of the Butte County Code and/or Resolutions indicated above for which fees have been ;j��Date1V PERMIT EXPIRES ON '(Det 1 provisions to do work paid. ReceiptNo. 167429 PLAN CHECK FEE 471.90 0�U WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLIYENROD-APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEV.ELOPIWENT SERVICES - BUILDING DIVISION U. -7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-7541 PERMIT o. APPLICATION AND PERMIT PERMIT ASSESSOR PARCEL NUMBER '�?O �f ZONWG I BUILDING PERMIT OWNER ,c7 \ TELEPHONE 6 73` SO. FT. OCC. BUILDING VALUATION OWNER'9 �;LIORESS /C I�55 1l CONTRACT SNAME ( TELEPHONE` ��oO 4 3� CONTRACTOR'S MAILING ADDRESS Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation $ C+ 8 u:NDeas MAILING ADDRESS Filing Fee $ 20.00 Permit Fee $ /. _-5-v '76- ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 3(08.170 Energy Plan Checking Fee $ Z -3 CX� ARCHITECT OR ENGINEER'S MAILING ADDRESS dq Penalty $ BUILDING ADDRESS !' PERMIT FEE $ pO PLUMBING PERMIT Filing Fee .00 Each Trap 7,00 6.7 Solar or heat pump water heater 23.00 :OTN SUBOIVISION'SNAMEqq %`C�ll,t• 4%, %°r.� tai /�f PARCEL MAP - zz?i Water piping. 15.00 /S-- Each gas water heater or vent 15.00 USE OF STRUCTURE S Duplex O Mobilehome O Other SPECIFY Gas piping system 1 - 5 outlets 15.00 Building sewer 15.00 5 Mobile Home S G I W @20.00 TYPE OF WORK New Addition ❑ Remodel O Utilities O Installation O Other ❑ Describe Work: ✓ �(� S�' PERMIT FEE $ �p Contractor ELECTRICAL PERMIT Filing Fee 20.00 RLEss Main Service ( eoovo) 200A OR LESS 23.00 • � Main Service ( 200A TO I000A ) 46.00 NEW CONST. DWELLING OCCUP. OR AODNS. ( 6 ACC. BLDS. ) 3.5C SO, FT. O NEW CONST. MULTI.OUTLET NON•RESID. ( BRANCH CIRCUITS ) @7.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (check one) ❑ I am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. Classification Cl I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) ❑ I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) ❑ I am exempt under Sec. Business and Professions Code forthis reason ( POWER APPARATUS ) & SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 @ 1.00 BAL. Q .BO Ex. Occup.FIXED APPLNS. OR ( OUTLETS IRESID.I EA. ) 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. ❑ I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 16,60t7 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ S s0 Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes.G I also agree to save., indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue gainst s id County in consequence of the granting of this permit. X - Date Signature of Applicant - ❑ Owner ❑ Contractor ❑ Agent An OSHA permit is required for excavations over 5"0" deep nd demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $�� CONS/{. YPE �O ' V TOTAL FEES 33 1�5� IIZ. D. FEES IMP FL000 cDF PARCEL PD NO �^— 1 UE This permit is hereby issued under the applicable of the Butte County Code and/or Resolutions indicated above for which fees have been BY PERMIT EXPIRES ON /Date! provisions to do work paid. Date l / � Receipt No. (�/ IV WHITE-D.D.S.-B.O. CANA Y -ASSESSOR PINK -INSPECTOR GOLD NROD-APPLICANT f , COUNTY OF BUTTE BUILDING DIVISION, DEPARTMENT OF DEVELOPMENT SERVICES . 1469 Humboldt Road, Chico, CA (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed If you have any questions pertaining to this matter, or need additional explanation, c ta please ct this office immediately. REV 10/92 - ri �y-.�f:*'war'`s'�,�iv's,�'''l-ar-r�i�.aW�'�►�`,riy x':.:r.ai��r,y''^...7M«'�rii`+S'"4�.�`�y"� 4 COUNTY OF BUTTE g DEPARTMENT OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - 4916) 891-2751 .. 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 '- .z CORRECTION NOTICE] A routine inspection indicates that the following violations of Butte County Ordinances exist at the above addr and should be corrected. Please notify this office when correction'of work is complete . f you have any questions pertaining to this matter, or need additional explanation, please tact this office immediately. � aa� -41 r iA .'s '33 Date Inspector �/ d?jcol-x, REV 11/91 «'e i{ ^ r. °r•`a :4 JAN -11-95 WED 09:18 CHICO ECONOMY TOWING 9163450186 P.01 caner:_ i•L- � G`a permit No. l 2- SO l a N E R G Y C E it T I F I C A T 1 0 N Dana Road, Magalia, CA. 35 LOCATION - -- A. P. NO, - DESCRIPTION OF INSULATION ROOF Material- Thickness(inches)__ aterial_Thickness(inches)_ EXTERIOR WALL Material FIBERGLASS BATTS Thick�iess(inches)_3s" �Y'" CEILING Batt or Blanket TypeFIBFRGLASS BATTS Thickness(inciies)� i2"^ Loose Fill Type FIBERGLASS Minimum Thickneel(Incites) 16" Area covered(ft. ) 1000" FLOOR, ELEVATED_ Material Thickness(inches) FLOOR, SLAB Material_ Thlckness(inches) Width(inches) FOUNDATION WALL Materiel Thickness(inchea) Brand Name Thermal Resistance (R Value) Brand Name SCHULLER INT. Thermal Resistance{R Value) Brand Name SCHULLER INT. _ -,+b_-.- Theraial Real Its nce(R Value)�38 Brand Name SCHULLER INT. Number of Bags 3 Wt. per tag _ 44 It+• Thermal Resistance(R Value) R38 -Y Brand Name Thermal Roeistance(R Value)��'�•" Brand Name _ Thermal Resistance(R Value)M' Bund Name 'he".01 Reeiat40ce(R Val14e1_ I hereby -certify that the above iaaulAti:op -040 installed La Cha abova hN tin in confumance With the State of calif Ortl +� gnor ► t;agatram�altts. �i LOFRKE INSULATION CO., INC. 499150 STATE CONTRACTOR S LICENSE 1, Bnuary 11. SI TUBE (IF INSTAL A.TIC PPLICKrOR DATE~ -- I hereby certify the above insulation and all required items as shown on the Building Department approved plana and utt4cUmente have been installed as required by the State of California Energy Requirements. All equipment;devices quid materials are of the quality prescribed or are specifically approved by the State of California. � f? e.l� C* -k- FIRM NAI /OWER (Please print) SIGN RE OF r! RAL 'RAC'1'OR O1 �R� STATE CONTRACTOR S LICENSE Not t DATE THIS CERTIFICATE MUST.' BE ON FILE WITH THE BUILDING DEPARTM"T PRIOR To Y06L INSPECTION APPROVAI. AND A COPY 911ALI, BB POSTED WITHIN THE BUILDING January 1984 f �. 9F Installation Certiticate: nestuC,,t, ts, BUILDING OWNER- l[5 �.,,h !�% k //� �22 BUILDING PERMIT #: 74— 2S0 / . _BUILDING LOCATION: / 7 -7 -- An yAn installation certificate is required to be posted at the ouilding site prior to tK'e issuance of the occupancy permit. This form may be used to meet these requirements. All appliance categorises listed below are the actual equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better than the appliance specified on the Certificate of Compliance (CF -1 R). This certificate (or its equivalent)•shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. 1, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS Note: Hydronic boiler informalion is entered here. Other hydronic.or combined hydronic equipment is listed under Water Heating Systems. Heating Equip. CEC Cartitled Actual Distribution Duct or Heating Load Heating Type (fumace, Manuf..Make & Efficlency Type and Piping Before Over- Equipment heat pump, etc.) Model Number (AFUE, eta) Location R -Value Sizing (Stub) capacity (Stub) CEC Carti(lad Cooling Equip. Compressor Unit' Actual Distribution Duct or Type (air cond., Manuf. Make & Efficiency Type and Piping heat numn, etc.) Model Number SEER Location R -Value Tlie building design heat loss and design heat gain rate have been determined using a method spectlied in Section 15001 of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection. j_ � Siawre Date HVAC Subontractor (Co. Namq) or General Contractor or Owner WATER HEATING SYSTEMS Energy' External Water Heating CEC Certified Rated' Tank actor r Standby' In Tank System Type Manuf. Make & Input (kW Capacity Recovery store a as etc.) Model Number or Btuh(gallons) Efftcien Lose (%) R -Value ., S�710 ;r�ir %, s f 4c40— py6iou' . 1. For small gas storage (rated inputs 75,000 Stu/hr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (rated input >75,000 Etwhr), list Rated input. Recovery Efficiency and Standby Loss. 6 t For Instantaneous gas water heaters. list Rated Input and Recovery Efficiency. For Instantaneous electric water heaters, list Rated Input. FAUCETS & SHOWER HEADS - All faucets and showerheads installed are listed in the Commission's Directory of Certified Faucets and Showeriteads, : pursuant to Title 24, Part 6, Subchapter 2. Section 111. . Name) or General Contractor or Owner Date Plumoing Subcontractor (Co Sig `TIIIS CERTIFICATE MUST BE PROVIDED TO THE BUILDING DEPARIM.NT PRIOR TO `FINAL INSPECTIOI APPROVAL Air"7 A ()PY SHALL BE POSTED WITHIN THE BUILDING. JANUARY 1993 e.u. use uN�.l• Hot chin Attached Z! S Hour Plan Alutchcd YFS Sent to B.D. TO: Building Department ' FROM: E-nvironmcntal Health SUBJECT: Sanitation Clearance -yn��-r-2,44a- Owner Location Plan Approved for: Sewage Disposal Water Supply: I'uhlic _ Clearance for bedroom ni home. Other Hold final for: Final clearance' O.K. for: NOTE: Environmental � lth Specialist 8/92 1�y-.,? -? 35 / AP# Private Well �. 2 Date .r•r�.a•-v»L.tfrr+"Jw��t+x.,ir��1.�.. v'.�-,- _ .w 51.+;�: ""- F,a^rn'�r- ,..� r� _ ,.xr .. COUNTY OF BUTTE - DEPARTMENTOF DEVELOPMENT SERVICES -BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA J5965 -TELEPHONE (916) 538-7541 Proposed Building Use LICATION DATA SHEET Building Inspector At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1. All items have been submitted . ....................................... . 2. Plot plansj�5?4 sets, signed by preparer of plans. ......... 3. Complete plans04 sets, signed by preparer of plans . ..................... . 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............ . 5. Hazardous Material Form . .......................... . ............... . 6. Energy Design Compliance and supporting documentation. . 7. Statement of Intent for Non -Heated and A/C Buildings . ...................... 8. Engineered truss details and layout in duplicate (required prior to plan check). ... . 9. Mobilehome datayad manufacturer's installation instructions, 2 sets. ........... Q. Fees of $ ........... 1. Impact fees as shown on attached schedule. ...�lU.�� 12. California Department of Forestry plan approval/f es.� 13. Flood elevation letter (100 year flood) by California Engineer . ................. . 14. Sanitation and plot plan approval Health Department . ............ 15. City of Chico plumbing permit. ........................................ . -16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: . ......... 18. Contact Land Development about (A) Improvements (B) Drainage. .......... . 19. Driveway permit (construction approval required prior to occupancy). . .I IME Pre -Inspection reque 20. Pre -inspection for required. . to Building Inspector (Date) 21. Contractor's license information. (No., Name Style,. Classification) . .............. 22. Certificate of Workmans Compensation Insurance. ........................... 23. Owner -Builder Verification (Given to owner Mail to owner _). .......... T x'24. Recorded copy of Agricultural Acknowledgement Statement . .................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . ......................................... 28. Mobilehome utility clearance . .......................................... .29 Documentation of legal access . ..................... :.................. 30, ocumentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... Existing violations/expired permits . ...................................... 32. Plan check list . ..................................................... 33. 34. - -- -- ---- Wh�u issue the ermit, rocess as follows:•.. Mail ner. Mail to contractor. Telephone 3 - �S'K and hold for pickup at office. Deliver with inspector. Other Parcel Creation Acreage Applica Date Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution ate Copy of plans sent Health Dept. Fire Dept. Other D to By The following data must be submitted prior torm*t * suan ircle 1. Index permit for above items No. 2. Additional items required: Co itracto esigne , owner was advised of above required data by vphone _ mail Counter by � Date % on ractor, designer, ner, was advised of above required data by _ phone -mail Cojunter by _ Date Plans checked by O7 a- Date Plans approved by Date Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SZRVIczS - BU LDING . DIVISION 7 COUNTY CENTiR.DRIVE, OROVILLE CA 95963 - TELEPHONE (916) 538-7541 OWNER PROPOSED BUILDING USE... _., SCHOOL DISTRICT FEES (paid at District Office .... .................. 2. SHER= FEES (paid at Building Department) Residential...... x = unit amt. Commercial (sgf�1 x =$ ,sq.ft. amt. 3. URBAN AREA FEES (paid at Building Department) Residential (per unit) X___� - uni is Commercial (per sq.ft) x sq.ft. amt. A. P. DATE r REC. DATE R C /O Q 4. ON DISTRICT FEES (paid at District Office) ......................... 5. DRAINAGE DISTRICT FEES (Contact Land Development Division) .............. 4('P6. sRA FIRE INSPECTION AND PLAN CHEcg = X89.00...... 167 (paid'at Building Deparrment7 7. OTTER .t time of permit application, I Was advised the above fees are required to be paid rior to issuance of the permit. PPLICANT DATE COUNTY•OF BU77E Department of Development Se -vices Building Division Oroville: 7 County Center Dr.. Oroville CA 95965 Ph: 916-538-7541 Chico: 1469 Humboldt Rd., Chico CA 95928 Ph: 916-891-2751 OWNER-BLTILDER VERIFTCATION Attention Properry Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building .permit will be issued until this verificarion is received. 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement (yes or no) 2. 1 (have/have not)—/L—.k-v e signed an application for a building permit for the proposed work. 3. 1- have contracted with the following person (firm) to provide the proposed construction: Name Address City Phone Contractor's License No. 4. I plan to provide portions of this work, but I have hired the following person to coordinate, supervise, and provide the major work: Name Address City Phone Contractor's License No. 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: Name Address Phone Type of Work Signed: , Property Owner Social Security Number Date 9-- 7 4L. N TE: This Owner -Builder Verification is sent to you as required by Sections 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the permit. .+-i,7ce-..`A'ai`r^"T�T�I;►,�,'r�Sfi;';`�;q+E'!'�s?g�' ix�rr�e.-rr:;cr;rs�r"F$"�i'y°fim"y.s.:"""'."� p""'�T�t�r�`r-........«--•...-o.�-i-�v�-e?wu-.Nr�..rrs..±r^.J:]'7: nFx:��.ar.�+-r.�.s.,.g,�;'� "itf7^r:�.,.- BUTTE COUNTY SCHOOLS IMPACT FEE CERTIFICATION FORM (One Form Per Building) School District ` ` v�s� Building Department No. A.P. Number r Property Owner Property Location/Address Subdivison Residential Development . Commercial/Industrial' —' " rs�county Pit i �cNiwci nauvc Lot No. ❑ Sq. Footage / 45 Addition (Group R) Sq. Footage Addition (Including Exterior (`y ___,,_,Roofed Are as) t} Date (Floor Plans reviewed by School'District Personnel) Di rict Identification No.," School District certifies that (Applicant) (Street Address) (City) has complied with the requirements of Resolution No. representing square feet. (State) (Phone Nu ---,1 (Zip Code) by payment of $ �� 33190 ❑ . Check here if fee received represents "Full Mitigation". School Dis ri t Representative Date Paid by Check # � Remarks: \ . Bank Number Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency.=that this project is being reviewed under. the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feetormmkl (a/ea) EWIROHMIa AL HEALTH SEP .2 21994 Chlw, CaMornla 0 co 125.000 5' SET BACK -------------4------------------------------------------------------- ------------------�--' I I. I � APPROVED 20' PROPOSED _ _ Butte Coui)ty FUTURE Environmental Health ; 1 0, 9 0' �— SHOP ' Date Di (17 I � �':i ;:,ature -- - -- -- -- 4 6 -- -- ------------------- II ! i 10, !� 10, .i U s H U U S E jl --.__._ m ----------- -- --46-- -- -- --I � Iw I� - - - — —43,------- I -- I I --� 43' 0 10/ 1 0' l Z I L..... 43' 1 -.-.-. ------------------------------------------------------ ...... -.-.-. - . - I 51SET BACK -21 125,000 L 0 T 11 H P SCAT_ E o 1 !'Q" = 1. FOOT AP# GLI --22-35 IDRAWN BY RESIDENTIAL PLAN CHECKING GUIDE 8/91 (S.F., DUPLEX & MISC. ONLY) Bl OWNER dg. Perm .a t # A.P. #��- Plan Checker GENERAL f ning requirements: (sideyards and number -of permitted living units). luation. ans signed by designer. oper description of work on application. isting violations.on property. Items on data sheet. N.C., fees, Health, Developer Fees, License -law, etc). Recorded notice of violation. PLOT PLAN tComplete parcel size and dimensions. Setbacks, sideyards, easements, etc. Other buildings or structures. Grading, fills, drainage. Flood hazard. Special conditions on creation map, ustible, and foundations). FAU & FAS road setback. (noise, CDF., fire sprinklers, non -comb- . Building or utilities across lot lines (Record form). FLOOR PLAN Complete to scale plan with dimensions. e Required windows for light and ventilation (Sec. 1205). Required windows for second exit (Sec. 1204). Skylights (Chapter 34 & Sec. 5207). Human impact glass (Sec. -5406). -y Required room sizes, ceiling heights (Sec. 1207). GFCIs in baths, garage, kitchen, and exterior outlets (Article Light fixtures, switches,'receptacles, and exterior receptacles tenance of mechanical equipment. Locations of water heater, heating and cooling equipment, other or gas equipment. 8. Garage firewall,.door size, and closer (Sec. 503(d)(3)). 1- 1 - 3'0" exterior -exit door (sec. 3304 M. r Fireplace and wood stove location, alcoves, and clearance. 3 -.-Smoke detectors (Sec. 1210). 4r -.Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS 210-8). for main - electrical Standard bracing or engineered design (Table 25V) Unusual shape, size, or split level house requiring lateral design. Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. T- Foundation plan complete enough to construct building. Floor construction details complete.enough to construct building. Elevations and wall construction details complete enough to construct Roof construction details complete enough to construct building. Fireplace construction details and calcs if necessary. Rafter ties or bearing ridge beam.. rage door or porch header sizes. Stud heights. "Adobe soils - special foundation design. Retaining walls requiring design. 5s SIns ection required. building 8/91 RESIDENTIAL PLAN CHECKING GUIDE - MISCELLANEOUS ITEMS TO LOOK OUT FOR Stairway details: landings, rise and run, head clearance, handrails (.Sec. 3306). tGuardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). Exterior plaster - weep screeds (Sec. 4706). • Proper roof pitch for roof convering (Chapter 32). • Roof covering type - (fire hazard). • Foam insulation - protection. 36" halls and' stairways. • Living area over garage - complete 1 -hour separation required on garage side - including supporting walls and posts, etc. . Two exits on three-story dwellings (sec. 3303 & see Mezannines - 1716). 4. Attic access and ventilation (Sec. 3205). . Underfloor access and ventilation (Sec. 2516). 'r ' -Combustion air for fuel burning appliances - L.P.G. requirements. . Noise requirements on duplexes. Energy design. lashing at all exterior openings. . CDF responsible area requirements. �, Safra26$.1 of the Bt0-6=t de y Compzim tbs Rcitaowledgemeat be gdor to be== of a buiMfug i ibe properly d=dbed hadn is a0 mot to teled or bwh ded widdn an area Wnd fm tytetRut pI'll eaI and m ddeam of tilts property wmy be to incan, of No7 COMPARED �! &Womfm aeiet from am tae of qomlawl cbonicals. ORIGINAL DOOCtjMEN., including, but not iimiled to ham, pesdddm and bn m= sad from ft VMS& of q *01 mid opmdm hdaft. but not ibmioed to coltivReiom. p Whw. sem. nerd bwaft ofth 00CM&MIRYfts>era�e dos ADWk e. noise► nerd odor. Bette Comay hs eotR Ad ed sSficaUad aoaes which bon u a pdoday use bar prodoedve q 0cou d proposes ad addems whNn odd. aooes Rad on property d=M be papmed to mcgX sucb iLoavenieaoe or disc mmiorI ftom no®R1, 81COMsy fm m - AU do regi psq dy Ritsws in ft Comety of Bou. Staete of Cdifinnia. described as &dimes: All that certain real property situate in the County of Butte, State of California, described as follows: Lot 116, as shown on that certain Map entitled, "PARADISE PINES UNIT 14", which map was filed in the office of the Recorder, of the County of Butte, State of California, July 15, 1971, in Book 38 of Mapa, at pages 37; 38, 39, 40 and 41. EXCEPTING THEREFROM all minerals, oil, gas, asphaltum and other hydrocarbon substances, with provision that any and all mining operations shall be done from orifices outside the surface area of the land herein described and that no damages shall be done to the surface of said land. Zh= PROPERTY OWNERS: cm* of ) 0. bdixe me, to me oa an bob of swUM ea) to he tie Pm'�) shone nanee(s1 W& persuade teorsea to erne W f admot�ieta to ms Owl ter Add q "naftd the ana in WdhwIdWr aid mrW to the wtha MOWN" a>A ueaQeed, the PWMAO), or the eo ty upon � bP of whkh ti e,90alow)sm , d dwi by hidhwtbr des) Ou dee tnstr pwomwpadmu yep p - i i'do Alil4ir�7�Q I& MILL. ■ BUTTE COUNTY U Cfxffm. E4*8S 11prG 7 1997 t TABLE OF CONTENTS TOC Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 Project Address DANA OnTMM MAGALIA, CA 95954 Documentation Author... Robert A. Mangrum Company ................ PARADISE MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -TOC User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY TABLE OF CONTENTS Report Page FORM CF -1R ................ 1 FORM MF -1R ................ 4 FORM C -2R ................. 7 HVAC SIZING ............... 11 cou E�`t � Rosi p,P P CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 Project Address........ DANA COURT MAGALIA, CA 95954 Documentation Author... Robert A. Mangrum Company ................ PARADISE MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Stories.......... Floor Construction Type.... 1415 sf Single Family Detached New Front Facing 218 deg (SW) 1 1 Slab On Grade (Package D) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall R-13 0.088 Roof R-30 0.035 Door R-0 0.330 Roof R-30 0.031 VAULT SlabEdge R-0 0.720 SLAB FLOOR SlabEdge R-0 0.500 SLAB FLOOR FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Front (SW) 40.0 0.750 2 None None None Metal Window Front (SW) 15.0 0.750 2 None None Yes Metal Window Left (NW) 12.0 0.750 2 None None None Metal Window Back (NE) 20.0 0.750 2 None None Yes Metal, Door Back (NE) 17.0 0.510 2 None None Yes WoodDiv Window Back (NE) 6.0 0.750 2 None None Yes Metal CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM CF-1R- User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY FENESTRATION Tank Type Storage Heater Type Gas WATER HEATING SYSTEMS Distribution Type Number Tank in Energy Size System Factor (gal) PipeInsulation 1 0.62 EF 40 SPECIAL FEATURES/REMARKS WATER HEATER: AO SMITH FGR -40 OR EQUAL External Insulation R -value R-12 # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation (sf) Value es Description Shading Fins Type Window Back (NE) 10.5 0.750 2 None None Yes Metal Window Back (NE) 20.0 0.750 2 None None Yes Metal Door Back (NE) 17.0 0.510 2 None None Yes WoodDiv THERMAL MASS Area Thickness Type Exposed (sf) (in) Location/Comments InteriorVert Yes 5 1.0 KITCHEN InteriorHorz Yes 12 1.0 KITCHEN S1abOnGrade No 1415 3.5 SLAB FLOOR HVAC SYSTEMS Minimum Duct Duct Thermostat Equipment Type Efficiency Location R -value Type Furnace 0.800 AFUE Attic R-4.2 Setback ACSplit 10.00 SEER Attic R-4.2 Setback Tank Type Storage Heater Type Gas WATER HEATING SYSTEMS Distribution Type Number Tank in Energy Size System Factor (gal) PipeInsulation 1 0.62 EF 40 SPECIAL FEATURES/REMARKS WATER HEATER: AO SMITH FGR -40 OR EQUAL External Insulation R -value R-12 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan•to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... BRYAN MALLORY Name.... Company. OWNER Company. Address. 14030 DREXEL DRIVE Address. MAGALIA, CA 95954 Phone... 87 -1355 Phone... License. X72 2_ Signed. . %'—/ %-eY i-gned . . (date) ENFORCEMENT AGENCY Name.... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Robert A. Mangrum PARADISE MECH. DESIGN 5797 CLARK ROAD SUITE 16 PARADISE, CALIFORNIA 959 (916)877-SAVE/FX 877-7283 t MANDATORY MEASURES CHECKLIST: -RESIDENTIAL Page 4 MF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 Pr t Add oJec ress........ DANA COURT MAGALIA, CA 95954 Documentation Author... Robert A. Mangru Company.......... .... PARADISE m E MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc Climate Zone........... 11 Field Check Date MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM MF -1R User##-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (*) may be superseded by more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatory measures whether they are shown elsewhere in the documents or on this checklist only. BUILDING ENVELOPE MEASURES Design- Enforce- er ment *150(a): Minimum R-19 ceiling insulation. 150(b): Loose fill insulation manufacturers labeled R -Value. *150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls). J *150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. V 150(i): Slab edge insulation - water absorption rate no greater than 0.3%, water vapor transmission rate no greater than 2.0 perm/inch. 118: Insulation specified or installed meets CEC quality standards. Indicate type and form. 116-17: Fenestration Products, Exterior Doors and Infiltration/ exfiltration controls a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Manufactured fenestration products have label with certified U -value, and infiltration certification. c. Exterior doors and windows weatherstripped; all joints / and penetrations caulked and sealed. (/ 150(8): Vapor barriers mandatory in Climate Zones 14 and 16 only. 150(f): Special infiltration barrier installed to comply with MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 5 MF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM MF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY Sec. 151 meets CEC quality standards. 150(e): Installation of Fireplaces, Decorative Gas Appliances and gas logs 1. Masonry and factory -built fireplaces have: a. Closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. SPACE CONDITIONING, WATER HEATING AND.PLUMBING SYSTEM MEASURES Design- Enforce- er ment 110-13: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. 150(i): Setback thermostat on all applicable heating systems. 150(j): Pipe and Tank insulation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater). 2. First 5 feet of pipes closest to water heater tank, non - recirculating systems, insulated (R-4 or greater). 3. All buried or exposed piping insulated in recirculating sections of hot water system. 4. Cooling system piping below 55 degrees insulated. 5. Piping insulated between heating source and indirect hot water tank. *150(m): Ducts and Fans 1. Ducts constructed, installed and sealed to comply with UMC sections 1002 and 1004; ducts insulated to a minimum installed value of R-4.2 or ducts.enclosed entirely within conditioned space. 2. Exhaust fan systems have backdraft or automatic dampers. 3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible, manually operated dampers. 114: Pool and Spa Heating Systems and Equipment 1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions, no electric resistance heating and no pilot light. 2. System installed with: a. At least 36 inches pipe between filter and heater for MANDATORY MEASURES CHECKLIST: RESIDENTIAL Page 6 MF -1R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM MF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY future solar heating. b. Cover for outdoor pools or outdoor spa. .3. Pool system has directional inlets and a circulation pump time switch. 115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no continuously burning pilot light (Exception: Non -electrical cooking appliance / with pilot < 150 Btu/hr.). 1/ LIGHTING MEASURES Design- Enforce- er ment 150(k): 40 lumens/watt or greater for general lighting in kitchens.and rooms with water closets; and recessed ceiling fixtures IC (insulation cover) approved. COMPUTER METHOD SUMMARY Page 7 C -2R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 Project Address........ DANA COURT MAGALIA, CA 95954 Documentation Author... Robert A. Mangrum Company ................ PARADISE MECH. DESIGN Telephone.............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY MICROPAS4 ENERGY USE SUMMARY Energy Use Standard. Proposed Compliance (kBtu/s,f-yr) Design - Design Margin Space Heating.......... 15.69 16.51 -0.82 Space Cooling.......... 12.42 11.62 0.80 Water Heating.......... 14.74 11.62 3.12 Total 42.85 39.75 3.10 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type............, Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... 1415 sf Single Family Detached New Front Facing 218 deg (SW) 1 1 ReducedYear Floor Construction Type.... Slab On Grade (Package D) Number of Building Zones... 1 Conditioned Volume......... 11870 cf Footprint Area ............. 1415 sf Ground Floor Area.......... 1415 sf Slab -On -Grade Area......... 1415 sf COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY HOUSE 1 Wall 2 Wall 3 Wall 4 Roof 5 Wall 6 Roof 7 Wall 8 Door 9 Door 10 Roof 11 Roof Surface 197 Glazing Percentage......... 11.1 a of FA Yes W.13.2X4.16 .Average Ceiling Height..... 8.4.ft 218 90 No W.13.2X4.16 BUILDING ZONE INFORMATION R-13 308 Floor # of Yes W.13.2X4.16 Vent Special 0.035 Area Volume Dwell Cond- Thermostat Height Vent Area Zone.Type (sf) (cf) Units.itioned R-13 Type (ft) (sf) HOUSE W.13.2X4.16 77 0.035 R-30 38 Residence 1415 11870 1.00 Yes Setback 2.0 n/a R-13 128 OPAQUE SURFACES Yes W.13.2X4.16 20 Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 2 Wall 3 Wall 4 Roof 5 Wall 6 Roof 7 Wall 8 Door 9 Door 10 Roof 11 Roof Surface 197 0.088 R-13 218 90 Yes W.13.2X4.16 143 0.088 R-13 218 90 No W.13.2X4.16 260 0.088 R-13 308 90 Yes W.13.2X4.16 25 0.035 R-30 308 90 Yes R.30.2X12.16 342 0.088 R-13 38 90 Yes W.13.2X4.16 77 0.035 R-30 38 90 Yes R.30.2X12.16 297 0.088 R-13 128 90 Yes W.13.2X4.16 20 0.330 R-0 218 90 Yes None 17 0.330 R-0 218 90 No None 1090 0.031 R-30 0 0 Yes R.30.2X4.24 330 0.031 R-30 218 10 Yes R.30.2X4.24 VAULT HOUSE 12 SlabEdge 13 SlabEdge PERIMETER LOSSES Length F2 Insul Solar (ft) Factor R-val Gains Location/Comments 154 0.720 R-0 No SLAB FLOOR 20 0.500 R-0 No SLAB FLOOR COMPUTER METHOD SUMMARY Page 9 C -2R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 40.0 2 Metal Slider 0.750 218 90 0.88 0.78 None 2 Window 15.0 2 Metal Slider 0.750 218 90 0.88 0.78 None 3 Window 12.0 2 Metal Slider 0.750 308 90 0.88 0.78 None 4 Window 20.0 2 Metal Slider 0.750 38 90 0.88 0.78 None 5 Door 17.0 2 WoodDiv Hinged 0.510 38 90 0.88 0.78 None 6 Window 6.0 2 Metal Slider 0.750 38 90 0.8 8 0.78 None 7 Window 10.5 2 Metal Slider 0.750 38 90 0.88 0.78 None 8 Window 20.0 2 Metal Slider 0.750 38 90 0.88 0.78 None 9 Door 17.0 2 WoodDiv Hinged 0.510 38 90 0.88 0.78 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 2 Window 15.0 5.0 3.0 1.5 0.5 n/a n/a n/a n/a n/a n/a n/a n/a 4 Window 20.0 4.0 5.0 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 5 Door 17.0 6.67 2.5 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 6 Window 6.0 3.0 2.0 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 7 Window 10.5 3.5 3.0 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 20.0 4.0 5.0 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Door 17.0 6.67 2.5 2.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct -'Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 InteriorVert 5 1.0 24.0 0.67 R-0.0 KITCHEN 2 InteriorHorz 12 -1.0 24.0 0.67 R-0.0 KITCHEN 3 S1abOnGrade 1415 3.5 28.0 0.98 R-2.0 SLAB FLOOR COMPUTER METHOD SUMMARY Page 10 C -2R Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY System Type HOUSE Furnace ACSplit HVAC SYSTEMS Minimum Duct Efficiency Location 0.800 AFUE Attic 10.00 SEER Attic WATER HEATING SYSTEMS Duct Duct R -value Efficiency R-4.2 0.830 R-4.2 0.810 Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System Factor (gal) R -value 1 Storage Gas PipeInsulation 1 0.62 40 R-12 SPECIAL FEATURES/REMARKS WATER HEATER: AO SMITH FGR -40 OR EQUAL HVAC SIZING Page it HVAC Project Title.......... MALLORY/DANA COURT Date........ 09/1.3/94 Project Address........ DANA COURT MAGALIA, CA 95954 Documentation Author... Robert A. Mangrum Company ................ PARADISE MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -HVAC SIZING User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY GENERAL INFORMATION Floor Area.. ............. 1415 sf Volume .. .................. 11870 Cf Front Orientation........... Front Facing 218 deg (SW) Sizing Location............ PARADISE 2466 Latitude ... ...... ........ 39.8 degrees Winter Outside Design...... 30 F 1695 Winter Inside Design....... 72 F Summer Outside Design...... 99 F Summer Inside Design....... 75 F Summer Range ............... 34 F Interior Shading Used...... Yes. Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 Description HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 12177 4627 Glazing Conduction............... 4619 2639 Glazing Solar .................... n/a 5114 Infiltration ..................... 7251 2466 Internal Gain .................... n/a 2100 Ducts ............................ 2405 1695 Sensible Load .................... 26450 18641 Latent Load ...................... n/a 5592 Minimum Total Load 26450 24233 HVAC SIZING Page 12 HVAC Project Title.......... MALLORY/DANA COURT Date........ 09/13/94 MICROPAS4 v4.02 File-2MALLORY Wth-CTZ11S92 Program -HVAC SIZING User#-MP1342 User -PARADISE MECH. DESIGN Run -MALLORY T24 COMPLY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design.temperatures,.coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designers responsibility to consider all factors when selecting the HVAC equipment. Clearly the lx -,C Tested U -Values WMIJUVI CAI_IronNIA Cl.n oven 1:1.11 OVLII IIARD-CONT CI-n/CLR C1.11 OVrrl CAMW 1'%P8 _ UITAUL1 VALUE CLR/CLII CLII/CLrt AIIGON 11A1111 -CONT LOW -L' LOW-li A110014 IIIiAT IIAIIU-COAT uiw.c %ynirnr Cr-111111CATION M11111011 oil hill 11011 NUMBER 110111.7UNTAL CLEAn .55 :iLIUEll LOW -E .50 J0 .4II 4U 37 .31 t.26 MIL0393/U22-50/IIS i .^,IWGLE HUNG CLEAR .55 Low-E.5o .50 .4II ,qp 37 .3'1 t.20 1 r MIL0393/U?.2-51NS .l zWIt16OW PICTURE CLEArl.52 LOW -11.47 •40 •40 ,30 .35 .29 t.23 I MIL0393/U22-49/F > AWNING CASEMENT CLEAR .5B LOW -E.50 43 . 42 .3G 33 .27 t.23 MIL0793/U19-46/C SLIDING CLEAR .50 GLASS UO_Utt_ LOW -11.45 49 4II qp 3G 30 t.24 MIL0793/U23-49/SGD WIDE -STILE & CLEAn .50 BAIL DOUfi LOW -E.45 49 .40 • 41 .30 33 t• 29 MIL0793/U20-49/SGD 11O1t17ONTAL CUAn .a7 - -1 SLIDE Low -t .o2 , _ 73 G4 G1 MIL0793/U29-64/11 IIORIZONTAI. CLEA11.02 SLIDEII (GfltD) LOW -E.07 r 5 .73 ! .05 ..63 MIL0693/1.150-78/1-IS 'SINGLE CLEAR A7 1 11UNG LOW_E.On '1 .72 •G3 .60 MIL0793/U29-64/1-IS ,., SINGLE CLr:At1.92 L IIUNG (GRID) _ LOW -E.07 4 .72 .134 .61 MII-0093/U54-77NS t3) PI(:TUftE CLEA11.72 1 MI1-0593/U21-55/1" WINUUWLOW-E.157 11 59 4II 4G 1 PICTURE CLEAn .77r --' .4G MIL0693/U40-G1/P I z WINDOW (GRID) LOW -E.72 G1 .59 •50 / c CASEMENT/ CLEAn.07 , AWNING Low 11.02 73 .71 G4 .61 MIL0093/U30-G1/CA v CASEMENT/ CLEAn .92 S AWNING (GRID) _ LOW.E.07 .73 .72 --:G5 .62 MILOG93/U55-76/C -� GARDEN AIRE� CLEM 1.35 LOW -E 1.30 ' 1.35 N/A ' 1.30 N/A ' 110 BOO -j 7 77 G9 G4l � R --- I_ tl ) �k77. IIO .72 .69 I PATIO DOOR CLEAR .72 (415) LOW -E.67 •7 - *.72 .6G .G3 j 1 PATIO DOOn CLEAn.77 (415) (G1110) LOW -112.72 x.72 ',72 GG .63 IIOnIZONTAL CLEAn .G6 .4G MIL0793/U29-64/I IV's z SLI IDER -LOW-C.61 .64 •G2 .54 .50 .40 •-M SINGLE CLEAn .co - J IIUP!G LOW -11.61 G4 G I .53 ..50 .39 .3G MIL0793/U29-G4/1-IVS ' PICTURE CLEAn .55 WINDOW Low -E.56 •'4 .51 .42 .30 .32 ' 20 AWNING •� CL11An.6G m J cnscmer�r LOW -17.131 G1 50 52 49 39 36 MIL0693/U30-G1/CA nnvtus CLEAn .55 CC LOW -E .50 rr �' .52 .43 .39 r.46 .32 .26 MIL0593/U21-55/F SLIDING CLEAR .63 .41 .38 GLASS UOOIt LOW-E.So .60 .58 .49 SKYLIGIIT CLEAR NA I } 750 THERM OIIK .65 Low -11.60 1.65 NA '.GO SKYLIGIIT CLEAR .75 770 ALUM.LOW-E .70 *.75 NA' '.70 NA =" SKYLIGHT CLEAR .C,4 ti 7to0 VINYL LOW -E.49 '•J4 NA •.49 NA yr `UOUII-�` WOODCLAl) CLEAR .54 LOW -E.49 J 1 50 A3' .40 Thncn •11• v....__ _ - �1 -11111, i1cauon or varlous glass thlcluiesses and grid combinations. specific glazhlg option tYlay have -111 value of .02 to .03 lower than shown. alifornia Energy C01n►r Clislon Default Table 'U• Value. Ale„ With -I.- MC)t)Cl. A.- c; ......,,t dcUll rcA.-an 224�,1b .. r1carrz.An An Ann E,rCY "ie r. Tc c08T Nox, t2�1 a � .az 7g^in r�r;ccI-rn z7� 40,000. • .aa tto^i' •�i�10 No P(--40 -GIs 2.10 n 40,000 i .. $•1 10 Y�r two t;2,pOn .02. tcc)^/^ i�tc1 rGc •-30 -83 7tt"/o $.171 YF�9 2 r .4 n„1Q • AMOO '42 -�o 224 40,000 .08 ^ $140 No F«c -05 7•ra • • t�i`0 •• �i0,000 ••' • .42 OU"^ $140Yr�t 62,000. ,t;3 ' 7E1° .�1�1� Yr -'qt CaXl1.•�c� 7.�•t f7a7 . t : /e 171 No 1-ln 224 , n -y :3o,aoa:r:.:..66 '10% ,: 1', X11 -GU 224 ' 38,000 �a r4z -M-19z. 38,000 -83 7a�• $105 X24 /• $171 . rc;rt-�l --224 rt -1 (1 � 3b,bao ' • FGR -r0 ` 224 ��-1Q,•, :. 34�dUU rd2 70,18 8144 rrrt-�5 ' r� :2n2 tt_12•• ..;► 18,dpt) , • ,fid 7ti% ��1�ItS R-iUa ,zt)z z1q' 7b,1dt1 •,; _�_ $1�1g . ' h0,0 ..�., Nin . ►"'�t,I t-�c :o'�. ; = M�., NII .. Z�� °` i r 1-•10 7.7� *� 8,000 • . 27.130,000, C �(� .100 ,224 .. 7511 no .80 • 74% 117.1 . rt_10 •--- �___ P 8U Uqp r• rm-oto ...., . Nl/1 rrj-no .20r N/A . r�,.. , 2201 1.0 �2' . 00 7t1"/" ' .�P.40 zzz 4:x,000. rr�sr-�n 222 42,00Q ►-t.aa no^ie X15 f w -40T �t-14 , , 40,000 ' nR-0: .(�6 76 jd j' n'1 rt -1 1 is 1 S. 13 G a r -Jo 01.,! 48opw4 0, ' t n11Z.1 q , 1407- RR 09.�ye • • 4tsnnw : ,�� �!� r•�ja $407 Yr -9 Y>± YES Yr_r: Yr Yr_-;; No No N(.) No Nr) No NII Nin . N/A PARADISE MECHANICAL DESIGN Bob Mangrum 5655 Almond Street Energy Consultant Title 24 Residential • Title 24 Commercial Paradise, CA 95969 (916) 877-8881 Contractor's License #518627 (916)877-7283 (FAX) Installation Requirements For Building Department Submittal The following efficiency levels must be met, or exceeded, to obtain building permits and final inspection clearance PROJECT NAME- J�tq _�� JOB # INSULATION TYPICAL EXTERIOR WALL- R- 13 With R- — Rigid Insulation exceptions- — TYPICAL ATTIC/ROOF- R- 3o With R- — Rigid Insulation exceptions - TYPICAL FLOOR- R- may( With R- Rigid Insulation PYrPntinne_ — HEATING and AIR CONDITIONING UNIT ONE - SEER - /0, O AFUE/HSPF - 10 Duct Location - 4-ttc.; R -Value - UNIT TWO - SEER - AFUE/HSPF - _ Duct Location - c' R -Value - Notes - ZONAL CONTROL - YES-_Y__NO - HOT WATER HEATING QUANTITY- ENERGY FACTOR- 6Z Exterior Wrap R -Value- �z ELECTRIC GAS X RECIRCULATING PUMP YES- NO- JCC 3/4" PIPE or GREATER R-4 WRAP YES- NO - HOT WATER RECOVERY SYSTEM YES- NO - WINDOW INFORMATION TYPICAL- FRAME- Alc+ui4 LOW -E- Yes /(V, ARGON GAS- Yes /(jg) q7 NFRC Values- Operable -U= .i3 Fi� U= Fixed -— Doors -U=� Skylights -U= Exceptions-