Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
064-660-021
} AP 64-66-21 Ehrlich Ct. , ea t f SMagalia 64-66-21 Henr Loehr A'��/ W/ Ehrlich Ck+., app.300'S.of Slfyw y, M galia contr: HessBickhoe Serv., Paradise Permit #3950-7 P,E�.til.,MH) ELEC . F,�Q� 7 S ! S ePORT STRUCTURE REQ. AO COMPACTION TEST REQ. •F /�14� ��/; �•�� 64-66-21 contr: Richa d Marcotte, Paradise Permit #4650-"B,E(new pri.det.garage) . 4-66-21 !/C: Hilton's MH, Magalia Permit ##5339-79MHI / Is°5ued_ �64-66-21 contr: Ander&on Awning, Chico Permit #5911-79B(new awning/MH) 64-66-21 - ' Hehry1 Loehr 6414 Ehrlich'Ct., Magalia contr: Bernies MH Serv., Paradise Permit # 042-82B(new awning/MH YZ� 064-66-0-021 99-0477 P BILLET, William Re / 6414 Ehrlich, Magalia ';.g/dD (lpg_yard line) Del Johnson Htg 064-660-021 03-3697 ZAPPETTINI, RON 6414 EHRLICH CT.,1vra,GA NALE Cont: BRUCE BRODERIC EX MH PERM FND i 21 a� RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 COPY of Document Recorded 12 -Dec -2003 2003-0086507 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request. of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. RONALD E. ZAPPETTINI REAL PROPERTY OWNERILESSOR 5601 FOLAND MAILING ADDRESS PARADISE BUTTE CA 95969 CITY COUNTY STATE ZIP 6414 EHRLICH COURT INSTALLATION MAILING ADDRESS, IF DIFFERENT MAGALIA BUTTE CA 95954 CITY COUNTY STATE ZIP SAME UNIT OWNER (if also property owner, write "SAME") SAME MAILING ADDRESS SAME CITY COUNTY STATE ZIP UNIT DESCRIPTION BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MARING ADDRESS OROVILLE BUTTE CA 95965 CITY COUNTY STATE ZIP 03-3697 530 538-7541 BUILD PERMIT NO., TELEPHONE NUMBER 12-10-03 SIOW TI TRE OF LOCAL AGENCI 0MCLkL DATE NONE DEALER NAME (if not a dealer sale, write "NONE") NONE DEALER LICENSE NO. SILVERCREST 1978 HOWARD MANOR MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMEINUMBER A/B 3SC305CA 60'X24' 085354/3 SERIAL NUMBER(S) LENGTH X WIDTH INSIGNIA/LABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER AP # 064-660-021 SEE ATTACHED HCD FORM 433(A) REV. 8/91 6/13/2003 23:47 FAX 530 877 5214 .PARCEL ONE.: A portion of Sections 24 and 25, A r b d as follows• FIDELITY PARIDISE Order No. 301457 EXHIBIT "ONE" Township 23 North, Range 3 East, M.D:B'&M., esc e . Commencing at the section corer common to Sections 23, 24, 25 and 26 of said Township and Range; thence North 01 deg. 10' 00"'East 25.00 feet; thence South 89 deg. 31' 05" East 59.08 feet to the true point of beginning for the parcel herein described; thence from said true point of beginning South 89 deg. 31' 06" East 40.92 feet; thence North 01 deg. 10' 00" East 30.00 feet; thence South 89 deg. 31'06* _,feet; East 39.08 feet to a point; thence South 01 deg. 10' 00" West 226.03 feet to a point in the Southerly line of a parcel of land described in Deed from Osage Improvement Company, Inc., a Corporation to D. A. Hook recorded August 13, 1957, in Book 895, Page 177, Official Records: thence North 139 deg. 31' 06" West along the Southerly line of said Hook parcel 78.68 feet to a point; thence North. 01' deg. 10' 00" East 196.03 feet, more or less, to the true point of beginning. Excepting and reserving therefrom all minerals beneath the surface of any of the above parcel lying within the bounds of Section 24, with the right to mine and extract said minerals; it being agreed and understood that In all mining operations the surface will be protected against damage and that all of such mining shall be carried on from tunnels, shafts and drifts having their orifices outside of the surface areas of the above described realty, all as executed and reserved in the Deed from Magalia Mining Company, a corporation, to E. D. Storts and Ada 8. Storts, his wife, as Joint Tenants, dated august 19, 1947 and recorded September 4, 1947, in book 423, Page 385, Official Records, PARCEL TWO: A non-exclusive easement for road and public utility purposes over a strip of land. 60.00 feet in width lying 30.00 feat on each side of the following described road centerline: Being a portion of Sections 23,2 4, 25 and 26, Township 23 North, Range 3 East, M.D.B. &M., described as follows: Beginning at a point in the East line of Paradise Pines Subdivision Unit No. 5 as recorded on August 20, 1970, in Book 35 of Maps, at Pages 88, 89, 90 and 91, that lies North 01 deg. 10' 00" East 25.00 feet and North 89 deg. 31' 06" West, 100.92 feet from the Section corner common to said Sections 23, 24, 25 and 26; thence from said poirft of beginning, South 89 deg. 31' 06" East, 516.61 feet to a point in the Westerly line of a parcel of land described in deed from D. A. Hook to the County of Bune, recorded October 15, 1970, in Book 1639, Page 235, Official Records, to side lines to be lengthened or shortened as the case may be so as to terminate in said Westerly line. Excepting therefrom all that portion lying within the bounds of Parcel One, described herein. Assessor's Parcel No: 064-660.021 )ascription: Butto,CA Dcoument-Yoar.Doc= 2000.12637 Page: 2 of 2 )rder: stave co=aesst: 1008/008 �st4` -' ,. 'f 1�e+� s :� �[¢ x o�'�� y � �r,�K}`-{�..v x ��-����+p�F. � v �p t 9 �' _ �• � '� w �� �r �!?� �#'�i'��."'S�`+{� +� ��'r�i'' rF®U"NDAT_ ION �SSTElVI ,. . � '•-r YL+ �� �f ^4F `lt:Y x � :.� �d ,� ! as„�€AtR ,4h 't'�' .a' .`4a.". CERTIFICATE OFowl � CU� IANCY BUILDING PERMIT NUMBER: 03-3697 Address or location of unit: 6414 EHRLICH COURT, MAGALIA CA 95954 Legal Description of Real Property: AP # 064-660-021 SEE ATTACHED (x) Mobilehome/Manufactured Home () Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: RONALD E. ZAPPETTINI Owner's address: 5601 FOLAND PARADISE CA 95969 INSIGNIA OR HUD NUMBER: 085354/3 SERIAL NUMBER OR V.I.N.: A/B 3SC305CA MANUFACTURER'S NAME: SILVERCREST YEAR: 1978 OFFICIAL APPROVING INSTALLATION: � ldjm4, DATE: 12-10-03 PHONE: (530) 538-7541 H.C.D. 513C 08/14/2003 00:19 FAX 530 877 5214 FIDELITY PARIDISE STATE OF CALIFORNIA- BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT DMalon of Codaa and Standards 0 Decal #: LBB5082 Manufacturer: SILVERCREST Tradename: HOWARD MANOR Model: Manufactured Date: o0/0o/1978 Registration Exp: First Sold On: 00/00/1979 Title Search Date Printed: 08/08/2003 Q002/003 GRAY DAVIS, Governor Use Code: SFD Original Price Code: AHT Rating Year. 1979 Tax Type: LPT Last ILT Amount: Voluntary Conversion to LPT Date ILT Fee Paid: ILT Exemption: NONE Serial Number HUD Label / Insignia Length Width B3SC305CA 085354 60' 12' A3SC305CA 085353 60' 12' Record Conditions: PPF Exempt Voluntary Conversion to LPT Registered Owner: RONALD E ZAPPETT1Nl P O BOX 774 MAGALIA, CA 95954 Last Title Date: 08/01/2000 Last Reg Card: 08/01/2000 Sale/Transfer Info: Price $30,000.00 Transferred on 04/10/2000 Situs Address: 6414 EHRLICH CT MAGALIA, CA 95954 Situs County: BUTTE Legal Owner: WESTERN SUNRISE AKA CROSSLAND MORTGAGE 2865 SUNRISE BLVD STE 101 RANCHO CORDOVA, CA 95742 Lien Perfected On: 04/17/2000 10:00:34 Inactive Decal/DMV: DMV SS4116, DECAL ABA8208 Title Searches: FIDELITY NAIL TITLE CO 6141 CENTER ST PARADISE, CA 95969 Title File No: 305336 - WC *** END OF TITLE SEARCH *"* 08/13;2003 23:46 FAX 530 877 5214 FIDELITY PARIDISE 1� 005/006 RECORDING REQUESTED BY: 189111 NI I II91 HI Illi 119111919111 Fidelity National Title Company of California Recorded I REC FEE 11.88 Escrow No. 301457 -WC Official Retards I TAX 77.88 Title Order No. 00301457 When Recorded Mall Document CAl1DRCE J. f�RtIBi3S I and Tax Statement To: corde0(S�N I ROGERecorder Assistant I Raureen pr.�d��Zappettini Box 12:34PM 19-Ror-2910 I Page 1 of 2 Magalia, CA 95954 SPACE ABOVE THIS UNE FOR RECORDER'S USE GRANT DEED 2�D The undersigned grantors) declare(s) Documentary transfer tax Is $77.00 ( X 1 computed on full value of property conveyed, or [ ] computed on full value lose value of liens or encumbrances remaining at time of sale, ( i Unincorporated Area City of Unincorporated ' FOR A VALUABLE CONSIDERATION, receipt of which Is hereby acknowledged, Lorene Billett, Surviving Joint Tenant hereby GRANT(S) to Ronald E. Zappettini, An Unmarried Man the following described real property In the City of Unincorporated County of Butte, State of California: See Exhibit One attached hereto and made a part hereof DATED: March 31, 2000 STATE OF CALIF�RNI COU OF /j ON GAO before me, personally appeared personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(&) whose name(s) is/are subscribed to the within instrument and acknowledged to me that helshelthey executed the same in his/her/their authorized capacity(ies), and that by histher/their signatures) on the instrument the person(s), or the entity upon behalf of whlch the person(s) acted, executed the instrument. Witness my hand and o icial seal. Signature /SCC r -01 —"Mmumer— Lorene Bil!ett WENDY CSER COMM 911/1200 id G 1 NOU.RY PUBUCCALIFpRN15 - - BUTTE COUNTY 0 My Cam t Expires June 27, 2001 MAIL TAX STATEMENTS AS DIRECTED ABOVE FD -213 [Rev Mal GRANT DEED Description: Butte,CA Documant-Year-D*c= 2000.12637 Page: 1 of 2 Drder: stove comment: 08/13/2003 23:47 FAX 530 877 5214 FIDELITY PARIDISE (a006/006 Order No. 301457 EXHIBIT "ONE" .PARCEL ONE.: A portion of Sections 24 and 25, Township 23 North, Range 3 East, M.O.S. &M., described as follows: Commencing at the section corer common to Sections 23, 24, 26 and 26 of said Township and Range; thence North 01 deg. 10' 00" East 25.00 feet; thence South 69 deg. 31' 06" East 59.08 feet to the true point of beginning for the parcel herein described; thence from said true point of beginning South 89 deg. 31' 06" East 40.92 feet; thence North 01 deg. 10' 00" East 30.00 feet; thence South 89 deg. 31'06' East 39.08 feet to a point; thence South 01 deg. 10' 00" West 226.03 feet to a point in the Southerly line of a parcel of land described in Deed from Osage Improvement Company, Inc., a Corporation to D. A. Hook recorded August 13, 1957, in Book 895, Page 177, Official Records; thence North 89 dog. 31' 06" West along the Southerly line of said Hook parcel 78.68 feet to a point; thence North 01' deg. 10'00" East 196.03 feet, more or less, to the true point of beginning. Excepting and reserving therefrom all minerals beneath the surface of any of the above parcel lying within the bounds of Section 24, with the right to mine and extract said minerals; it being agreed and understood that in all mining operations the surface will be protected against damage and that all of such mining shall be carried on from tunnels, shafts and drifts having their orifices outside of the surface areas of the above described realty, all as executed and reserved in the Deed from Magalia Mining Company, a corporation, to E. D. Storts and Ada B. Storts, his wife, as Joint Tenants, dated august 19, 1947 and recorded September 4, 1947, in book 423, Page 385, Official Records. PARCEL TWO: A non-exclusive easement for road and public utility purposes over a strip of land 60.00 feet in width lying 30.00 feet on each side of the following described road centerline: Being a portion of Sections 23,2 4, 25 and 26, Township 23 North, Range 3 East, M.D.B. &M., described as follows: Beginning at a point in the East line of Paradise Pines Subdivision Unit No. 5 as recorded an August 20, 1970, in Book 35 of Maps, at Pages B8, 89, 90 and 91, that lies North 01 deg. 10'00" East 25.00 feet and North 89 deg. 31'06" West, 100.92 feet from the Section corner common to said Sections 23, 24, 25 and 26; thence from said point of beginning, South 89 deg. 31' 06" East, 516.61 feet to a point in the Westerly line of a parcel of land described In deed from 0. A. Nook to the County of Butte, recorded October 15, 1970, in Book 1639, Page 235, Official Records, to side lines to be lengthened or shortened as the case may be so as to terminate in said Westerly line. Excepting therefrom all that portion lying within the bounds of Parcel One, described herein. Assessor's Parcel No: 064-660.021 )ascription: Butto,CA Dccumont-Yoar.Doc= 2000.12637 Page: 2 of 2 )rder. stove Comment: NAIVE• AP#: DAIS: NOTES RESIDENTIAL 064-660-021 ZAPPETTINI, RON PERMIT NO. —_6414 EHRL-ICH CT; MAGALIA Cont: BRUCE BRODERICK EX MH PERM FND THE HCD FORM 433A FOR THIS MH CANNOT BE RECORDED UTOIL ONE OF THE FOLLOWING HAS BEEN TURNp6 IN TO THE BUILDING DIVISION: (1 ENSE PLATE(S) OR DECAL (THE `INSPECTOR MUST RETREIVE). (2) STATEMENT OF FACTS (ONLY ON NEW MH'S). INSPECTOR TO VERIFY SERIAL & LABEL #'S. SPECIAL CONDITIONS 0 CHECKED BY SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER JOB FINALED (Date) Signature J=OK D = Not OK Not Ready DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O -Concrete 4. Water; Location -Test -Easement Needed (Sketch) 6. 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete 7. 6. Gas; Location -Test -Wrap;-/ /" L 'ft. / P Nat. or/ /" L "ft./ P LPG 8. 7. Well Clearance & Disconnect 9. 8. Utility Clearance 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements POOLS (Plans) OK except #'s 2. Footings; Size -Spacing -Marriage Line Setbacks -Easements 3. Gas; MH Test -Demand -Valve -Connector Soils; Compaction -Structure Stability 4. Electricity; MH Test -Crossovers -Breakers -Clearances Pool Structure; Steel -Connections -Thickness Dead Men -Lining 5. Drain; MH Test -Fall -Flex Connector Elec.; Receptacles and Lighting, Distance-GFI 6. Water; MH Test -Regulator -Connector Elec.; Pool Lighting; 15 Volts-GFI 7. Water and Sewer Connected -C/O to Grade -HD Approval Elec.; Enclosures; Conduit Entries -Terminals -Listed 8. Gas and Electricity Tagged Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 9. Tie Downs -Type -Installation Cert.. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main Conduit 10. Exits; Insp.-Sketch 9. 11. Cert. of Occupancy 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Enclosure; Fencing -Alarms Card B-1 Date Card B-1 Date Cajd 3-1 Date Card B-1 Date PEIRMANENT END SYSTEM (ONLY) Line r4,/Gas; MH Test -Demand -Valve 3.--ETe_ctricity: MH Test meter; MH Test Z:t.-��er and Sewer Connected 8. Gas and Electricity Tagged .9. Wits . icense Decals 11. Verify #'s with Office p' Date C R® Card B-1 u Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall.Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = NotOK = Not Applicable Applicable . = Not Ready RESIDENTIAL Date UNDERFLOOR (Plans) OK except #'s Date 1. Zoning -Setbacks -Easements -Flood -Slope Date 2. Ftg., Main; Soils-Elec. Grnd.-/ P' Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth Fireplace Ties or Type A Flue -Fireplace Throat Clearance 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 50. 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 6a. Hold Downs and Special Anchors 52. 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel Property Line Firewall & Openings 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test Date 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test Date 11. Water Pipe; Test -Anchors -Regulator -Service Test Date 12. Electric Underground 56. 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 16. Insulation (Single & Duplex) Date FRAMING (Continued) Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle Fireplace Ties or Type A Flue -Fireplace Throat Clearance 18. Water Pipe; Test & Anchor -Nail Protection 50. 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 21. Test Tub & Shower, Second Floor -Tub Access 52. 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test Property Line Firewall & Openings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 56. 24. Fixture & Transformer Clearance -Ins. Protection 25. Elec. Receptacles Spacing -Lights & Switches at Doors 26. Size Boxes & No. of Conductors Stapled Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 27. Romex Installed Close to Edge of Studs & C.J. 59. 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 29. 2 Appliance Circuits in Kitchen & Conductor Size GFI Shear Walls; Nailing -Bolts 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 61. 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or Al Insulated Neutral O Yes O No 32. Service -Riser Conductors & Ground Main Disconnect Insulation -Walls -Ceilings 33. Equip. Clearances Panels-Motors-Mech. Equip. 63. 34. Clothes Closet Light -Shower Light -Spa Light Date 35. Smoke Detector Card B-1 Date Card B-1 Date Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s Ext. Steps -Door & Sidelight Protection -Landings 36. A.C. Ducts Insulation & Support 65. Smoke Detector 37. Vent Fan, Exhaust above insulation 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 38. Condensate Drain & Overflow, Size & Grade 67. 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s 41. Sills Proper Materials & Anchors Fireplace or Stove, Clearance -Hearth 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 72. Elec. Outlets at Wood Panel, Int. & Ext. 43. Bearing Walls over Girders & Floor Nailing 73. 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs Elec. Outlets & Receptacles at Kit. Counter 46. Headers & Beams -Size & Bearing Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 83. Following Instld./Drive O Yes O No/Walks O Yes D No/Planters D Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: .C,AUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-755 . - ,HERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT UD- - C17 ASSESSOR 17 ASSESSOR PARCEL NUMBER 064-660-021 ZONING R-1 BUILDING PERMIT OWNER PM ZAPPErrM 877-3826 TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNER'S MAILING ADDRESS 5601 FOI.AND PARADISE CA 95 76000 • CONTRACTOR'S NAME BRUCE BRODERICK TELEPHONE 87305059 CONTRACTOR'S MAILING ADDRESS PO BOX 786 MAGALIA CA 95954 CONSTRUCTION LENDER LENDER'S MAILING ADDRESS Fireplace Total Valuation $77,760.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit Fee $ 270.25 Plan Checking Fee $ 23.00 BUILDING ADDRESS 4 A Energy Plan Checking Fee $ PERMIT FEE $313.25 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap7.00 Solar or heat um water heater 23.00 Water piping 1 15.00 L5.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: EX MH PERM M Gas piping system 1 - 5 outlets 15.00 • Building sewer 15.00 Mobile Home IS I G1 W @20.00 PERMIT FEE $50- ._00 -ELECTRICAL PERMIT Fling Fee 20.00 Main Service E00Y OR LESS 2o.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencingwith Section 7000 of Division 3 of the Business and Professions Code, ) and my license is in --full force and effect./ License Class j Lic. No. �, /�/ OWNER -BUILDER DECLARATION 1 hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP.SO OR ADONS. ( a ACC. BUDS. 3.5¢x; NEW CONS . MULTI.OUTLET NON-gESID. @7.50 POWER APPARATUS a SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FIXTURES BAS @' 0 Ex. Occup. oFIxLI EDTSA Aa ORS 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall 1` not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. X / / I l ) % le /11.(flam"--Date /✓ Vt— Signature of Applicant - ❑ Owner ❑ Contractor p,/Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee $ Energy Inspection Fee $ OCC CONST. TYPE TOTAL FEE $ 363.25 HAZ. y1�, CDF PARCEL Po HD ISSUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By _ //%•*!i t- Date i i PERMIT EXPIRES ON — .'1 - ! U Dale Receipt No. WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538 — P RMIT NO. (Rev. 12/96) APPLICATION AND PERMIT ASS%4PPr- E 1 ZONING R-1 BUILDING PERMIT OWNER RON ZAPPETTINI 877-3826 TELEPHONE SO. FT. OCC. BUILDING VALUATION 1440 R 77 760.00 . OWNERS MAILING ADDRESS 5601 FOLAND PARADISE CA 95969 CONTRACTOR'S NAME BRUCE BRODERICK TELEPHONE 873-5059 MAILING ADDRESS PO BOX 786 MAGALIA CA 95954 CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 77 760, 00 ARCHITECT OR ENGINEER LICENSE NO. Filen Fee $ 20.00 Permit Fee $270.25 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 2-3.00 BUILDING ADDRESS 6414 EHRLIC Energy Plan Checking Fee $ $ PERMIT FEE $313.25 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Unities ❑ Installation ❑ Other ❑ Describe Work: EX MH PERM FM Gas piping system 1 - 5 outlets 15.00 15.00 Building sewer 15.00 Mobile Home I S I G W 920.00 PERMIT FEE $50.00 ELECTRICAL PERMIT Filing Fee 20.00 gooOR LES Main Service 20 OA OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is i full force and effect. �� 7 ✓ License Class Lic. NO. OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ 1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ 1 have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Policy Number (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) `Q I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisi ns of section 3700 of the Labor Code, I shall ith ose pr visions. Xirithwith comply with, Xa e Signature of Applicant - ❑ Owner ❑ Contractor Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. Main Service 200A TO 1000A 46.00 NEW CONST. DWELLING OCCUP. SO OR ADDNS. ( i ACC. BLDs. 3.5QFT; T. NppypESID. MU LTI.OUTLFf 97,50 POWER APPARATUS d SINGLE OUTLET CIR. 20 O 1.00 Ex. Occup. OUTLEr OR FOCTURES BALL p .50 Ex. Occup. GLIFIxxEDA AaDOEA 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt: $ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 363.25 HAz.MP FLOOD cDF PARCEL PD HD IS E This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By Date PERMIT EXPIRES ON.D.S.-B.D. �� ate No. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT E 12/96) CODS OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION County Center Drive • Oroviile, California 95965 - Telephone (530) 538-7 _ PERN APPLICATION AND PERMIT _ BUILDING PERMIT J 7MEPMUE SO. Fr. OCG BUILDING VALUATION ia4la -7 _ -7 Ue20 b WUNG ADD %/ TOWS NAME ARCWe= OR ENGINEER ARCNRECT OR ENWYeER 3 AWLiNG ADDAf 'S Permit Fee Pian ChecId GFEaach lan Checking Fee PERMIT FEF LOT NO. SUMMONS NAME ° ¢UMBING PERMIT ap USI=QFSTRUCTURE Solar or heat pump water heater SF ❑ Duplex D Mobilehome 4—(3#W Water piping_ 3° Each gas water heater or vent TYPE OF WORK Gas nkgna system 1 - 5 outlets 0 s New ❑ AddiS n et C1 Ugh -t �s� k Ra O Other /!ice–x Buildin sewer DescribeWork: Y�//ylf /i/� O7 Mobile Home I S G I 1N PERMIT FEE S ELECTRICAL PERMIT aoav Main Service 20G40RoR LLESSESS {main .Service ( nm -ro +com N Ping Fee 20.0 7.00 23.00 15 oo (� 1 .00 15.00 $' 15.00 @20.00 Fee 20.0 23.00 66.00 PERMIT FEE PAID $ mE Ex OCCLf OUMV OR FMMES elu @'.s�o FJL Occup. . OUTLOSJREWiFUMD D EEA 5.00 SRA Tem or Service 23.00 Mobile Home Facilities 20.00 We. Wiring 23.00 . SHERIFF $ PERMIT FEE 14 RtienEC NICAL PERMIT Filing Fee 20.0 OTHER $ Heating 6.50 $ PERMIT FEP- e Installation Fee 5 $ Energy inspection Fee $ O= CONST. rife TOT•AL FEE $ 3 3 D- FEES 117P FL1mD COF OARRa• D. NO M AMOUNT RECEIVED $ 3 C� 3 • — — — This permit Is hereby issued under the applicable provislor '?� of the Butte County Code and/or Resolutions to do wo DATERECEIVED . I 3 'indicated above tot which tees have been paid. By Date 3� 39� COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA 95965 Phone (530)538-7541 Fax.(530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: SS SSOR PARCEL NUMBER to �o O - I Proposed Building Use: k d' I i� 1 Counter Technician: Date: / ,314 0_3 w� Itenysrfequired in order to apply for a permit. All boxes MUS a checked OR marked NA in order to apply. a �� Er 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. f+OV Q, C ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxes! ❑ 5. Letter from Engineer or Architect for truss design review. ❑ 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. L� 8. Manufactured homes: (A) Data sheets and installation inst, (B) Marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate ❑ 11. Site plan and business license approval from the City of Biggs ❑ 12. Letter of intent for non-residential buildings ❑ 13. Detached Accessory Building Form filled out by the owner ❑ 14. Hazardous Material Form ❑ 15. Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable. ❑ 16. Other Remaining items needed to issue the permit. (May require additional plan review upon receipt of the =ollowing items.) ❑ 17. Fire Sprinklers............................................................................................ ❑ 18. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 19. Soils Report and/or Engineered Foundation required ........................................... ........ ❑ 20. Erosion Control Plan Required........................................................................ ........ ❑ 21. Fees as shown on the attached Schedule of Fees Due Sheet .............................. ❑ 22. City of Chico Plumbing permit........................................................................ ❑ 23. California Department of Forestry plan approval ❑ paid. Sent by: ............. ❑ 24. Planning approval (A) Use: (B)Parking: (C) Parcel Check: ❑ 25. Contact Land Development about _ Improvements, _ Drainage ......................... ❑ 26. NPDES Form............................................................................................. 27. Encroachment Permit -for drive�va-y, ff o t e Pu Ii Works Dept ...... :................... / - 28. Pre -Inspection for VYI' (�f y required....... 29. Contractor's license information. (Number, N me Style, assification)................... ❑ 30. Worker's Compensation Carrier and Policy Number .................................... ...:.. ❑ 31. Owner -Builder Verification (_ Given to owner, _Mailed to owner) ..................... ❑ 32. Letter of Signature authorization.................................................................... ❑ 33. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 34. Manufactured home utility clearance............................................................... ❑ 35. Existing violations and/or expired permits......................................................... ❑/ 36. Deed RestrictionO'H' ................................................................................... . ; 37. /Mrant Deed, �1HTitlelStatement of Facts, *tter from Legal Owner, Teck to H.C.C. $ ❑ 38. Other: ❑ 39. Other: When issued Telephone and hold for pickup. I have been inforr'ed of the above iterps and requirements for obtaining a building permit. Applicant: Date: 1-)�/3 / 3 1. Index permit application for the above items numbered: Plan Check :Letter �o=ntal items required ractorr, , designer, owner, was advised of the above data by phone, ❑ mail, ❑ counter, by Date: 5' 3 designer, owner was advised of the above data by P phone, ❑ mail, ❑ coun r b Date: 4 a Plans reviewed by: Date: Plans approved by: Date': Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Date: Yellow: Building Division i Building Permit Number: 103- -3& 9 7 Owner Name: za p p 2 � Residential Construction Requirements IMPORTANT This set of plans and specifications MUST be kept on the job site at all times and it is unlawful to make any changes or alterations on same without written permission from the Building Division, County of Butte. All materials and workmanship shall be in accordance with recognized good practices and of a quality prescribed for the specific use in the 2001 California Building Code (2001 U.B.C), 2000 California Plumbing Code ( 2000 U.P.C.), 2000 California Mechanical Code (2000 U.M.C.) and the 1999 California Electrical Code (1999 N.E.C.) COMPLY WITH ITEMS CHECKED BELOW KIYour parcel lies within a designated 100 -year flood plain. Finish floor, electrical, H.V.A.C. equipment and services shall be a minimum of one foot above the elevation shown on the attached Flood Elevation Certificate. A Post Flood Elevation Certificate will also be required Note: We will normally accept the following as compliance with the flood elevation requirements: 1. Building is anchored to concrete stemwall system with conventional anchor bolts. 2. Building plate on top of stemwall to be one foot or more above the 100 -year flood elevation. (Plate height less than 24" above grade, or engineered design required). 3. Electrical, heating, ventilation, plumbing and air conditioning equipment and facilities located above the plate. 4. At least 2 openings in exterior walls, located on opposite or adjacent walls with a total net area of not less than 1 square inch for every square foot of enclosed area. 5. The bottom of the openings shall be no higher than 1 foot above grade. 6. The openings may be screened or covered with other devices that will permit automatic entry and exit of floodwater. Page 2of 2 Building Permit Number: Q 5 -30 7 Owner Name: yR Parcel lies within the State Responsibility Area (SRA). Comply with attached requirements. M �T_ Fire sprinklers are required in this structure. The following parcel map requirements shall be met: All structures a4d equipment including overhangs shall be clear of all easements. A setback of� feet from the side and 15 feet from the rear property lines and 20 feet (25 feet if Federal Aid Route) from the edge of the right of way shall be clear of structures and equipment except for a 2 foot overhan . s,�- re. a Expansive soil may be encountered on this site. This condition may require the Y Y q foundation to be designed by a California registered engineer or licensed architect. 0 1. - Owner's name: 2. Installer's na BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS 7 County Center Drive, Oroville, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 3. Is the site currently under permit? Yes / No (If yes, furnish permit number ) OR Is the site an existing site? Yes / / No (If yes, furnish two (2) plot plans.) 4. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes % % No ( If no, clarify ) 5. What is the mobilehome electrical rating? ----------------------- ` Amps 6. What is the mobilehome site service rating? ---------------------Amps 7. What is the mobilehome site circuit breaker rating? ------------- Amps 8. Is there any other electric load to be served by the mobilehome siteservice? --------------------------------------------------- Yes _� No (If yes, identify the load and size: (Load) N\ (Amps) 9. What is the mobilehome site gas pipe size? ---------------------- (in.) 10. What is the type of gas service? ----------------------------- Natural / %:. LPG 11. What is the gas pipe length.from meter or tank to the mobilehome? (ft.) 12. :What is the mobilehome gas demand? ------------------------------ (BTU) (This information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) gUIL:DING DEPARTNIF-:. 4PPR()VF MOBILEHOME SUPPORT DATA If other than 'single wide,�� Mobilehome Mfr. !,�P��'/fff.� furnish Setup Model No. Year Width (ft.) Box Length 6C(ft.) Tagalong or Expando Size ft. x ft. (SHOW SUPPORT DETAILS BELOW) c On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation manual and structural setup sheets (if not on file with the County of Butte). All center supports measured -oxi--�7 of mobilehome unless otherwise specified. o (ft.)(in.) (in.) (in.) (ft.)(in.) (in.) (in.) (ft.)I (in.) (in.) (in.) Footings (check one Single 1. Wood either Ilk AApressure treated !/® N SUILDiNG DEPARTMEN`` t APPROVED; •y . foundation grader (ft.)(in:) x (in.) (in.) D 2. Other (specify) Center support Center support locations* footing sizes Supports (check one (in.) 1: Concrete block. �L7/�1 2: Other (specify) (ft.)(in.) (in.) (in.) 14/ o (ft.)(in.) (in.) (in.) (ft.)(in.) (in.) (in.) (ft.)I (in.) (in.) (in.) *If center piers are other than drawn above, 4�—Tagalong or Expando,' show support details OSS xJ -- Typical Support in. (in.) Footing Size Max. Pier Spac in�- ���� i -- Max. Overheeng� Ilk BUTTE COUNTY !/® N SUILDiNG DEPARTMEN`` t APPROVED; •y . *If center piers are other than drawn above, 4�—Tagalong or Expando,' show support details OSS xJ -- Typical Support in. (in.) Footing Size Max. Pier Spac in�- ���� i -- Max. Overheeng� BUTTE COUNTY !/® N SUILDiNG DEPARTMEN`` t APPROVED; •y . `Vector Dynamics Foundation System INSTALLATION INSTRUCTIONS for the State of California Version 9/2/2003 SECTION INTRODUCTION _ GENERAL INSTALLATION PARTS LIST LONGITUDINAL DEVICES PIER HEIGHTS SET-UP INSTRUCTIONS FOOTER SIZES INDEX PAGE NUMBER 2 3 4&5 6 7 8 RELEASE DATE. 9/2/03 9/2/03 9/2/03 9/2/03 9/2/03 9/2/03 WIND ZONE I - SINGLE 9 9/2/03 - DOUBLE 10 9/2/03 - TRIPLE 11 9/2/03 - HIGH PIER 12 9/2/03 WIND ZONE II - SINGLE 13 9/2/03 - DOUBLE 14 9/2/03 - TRIPLE 15 9/2/03 V -DRIVE & PIER SYSTEMS 16 9/2/03 SOIL CLASSIFICATION 17 9/2/03 CONCRETE INSTALLATION 18 & 19 9/2/03 COMPONENT PARTS AVAILABLE UPON REQUEST Approval MANUFACTURED HOMEIMOBILB HOME FOUNDATION SYSTEM HEALTH AND SAFETY CODE. SECTION 18"1 APPROVED SUBJECT TO CORRECTIONS'NOTED kPPROVAL DOES NOT AUTHORIZE OR APPROVE ANY MISSIONS OR DEVIATION FROM REQUIRMINTS Oil APPLICABLE STATE LAWS AND REGULATIONS Smte of California ��MN o%%��fland Comm uWV Develop=w* CODES AND STANDARDS I cairi� SPA This Aemoval Emira Q 3 — 3& `17 /77 C- AUIL.DING DEPARi-ME, PPROT co 0 N O O O Tie Down Engineering, Inc. VECTOR DYNAMICS INSTALLATION DESIGN INSTRUCTIONS Introduction These instructions describe the proper use of.the lateral and longitudinal foundation system. You may also refer to the home manufacturer's installation manuals that include the Vector Dynamics system as an alternate foun- dation system. General The Vector Dynamics Foundation System provides the support to resist lateral, longitudinal and over -turning movement of the home as required by the Federal Manufactured Home Construction and Safety Standards in a specified wind zone when the system is used as described in these instructions. Please. verify state or local wind load requirements prior to installation of the home. The Vector Dynamics'Foundation System resists lateral & longitudinal wind & seismc loads by anchoring the two longitudinal main rails. The system is approved to be used on single or multi section homes: Nominally 12 feet to 16' feet wide- (single section) with main rail spacing of 95 inches or greater on center; multi section main rail spacing of 75 inches or greater on center. Nominal 8 foot or less top plate height at sidewalls with main rail depth of 12" or less. Maximum roof slope of 20 degrees (4.4" in 12" slope). Maximum eave width (roof overhang of sidewall) of 12" for Zone I, 8" fo Zone II Maximum pier height under main rails -see page 7. The Vector Dynamics Foundation Systems may be used as a part of the vertical or gravity support system con- sidering that each Vector Dynamics pad has two (2) or (3) square Teets bearing area. To inquire about the use of the Vector Dynamics Foundation Systems with homes of four or more sections, other widths, or on homes requiring pier heights which are not included in these instructions, contact Tie Down Engineering, Inc. at 1-800-241-1806. The Vector Dynamics Foundation System has not been designed for use on exposure "D" homes within 1500 feet of the coastline. Additional vertical anchor ties that are unique to a home's design may be required by the home manufacturer. These locations may include shear walls, marriage line ridge beam support posts, end frame ties and rim plates. 1:0 C pC p Page 2 California 9/2/03' GENERAL INSTALLATION INSTRUCTIONS SITE PREPARATION It is necessary that the home site be properly graded and sloped to prevent water and moisture from standing or flowing beneath the home. FOOTINGS AND FROST LINES The Vector Dynamics Foundation System was designed to be placed directly on top of the ground (or poured concrete) after clearing all loose vegetation. In areas with frost heave, use Vector for Poured Concrete (see pages 20 & 21) to comply with local requirements for footer depth. FOUNDATION/FOOTING SPECIFICATIONS FOR VECTOR PADS Vector Pads are used in place of conventional foundation pads. One Vector pad provides two or three square feet of bearing support. Vector Systems should be spaced as symmetrically as possible along the length of the home. For pier locations in between the Vector Systems, use the normal foundation pads. LUMBER/MOISTURE -TERMITE SHIELD To. cut PVC or lumber (2 - 2x4's,1 - 44 or 1 adjustable steel commpression member per Vector system) for the center compression section,when using concrete blocks for piers, measure center to center frame (I-beam) dis- tance and subtract 16". When using METAL PIER STANDS, measure center to center frame distance and add 16". ALL WOOD MUST BE PRESSURE TREATED, GROUND CONTACT RATED. Tip: Pre-cut your lumber and mark as to brand or model of homes you will be installing. If frame widths are the same, the pre-cut boards will also be the same length in each Vector set-up. STRAP: INSTALLATION All frame ties and diagonal straps must go from the anchor to the top of the I -Beam. See illustration below. 1. Attach frame hook to top inboard location of "I" beam. (Frame hook must be attached to frame at points closest to floor support.) 2. Keeping in line with the hook, wrap galvanized strap completely around "I" beam. 3. Pull strap past anchor head approximately ten inches before cutting to allow enough strap to give a minimum of five turns around the slotted anchor bolt. 4. Thread loose end through slotted bolt so that the strap is flush with the other side of the bolt. 5. Tighten slotted tensioning bolt a minimum of five full turns., Page 3 California9/2/03 Vector Dynamics Foundation Systems Lateral Component Parts List Vector System Lateral Stabilization Block Pads #59018 - 2 sq. ft. single/double block pads with hardware, swivel straps and slotted bolts Vector System Lateral Stabilization for Concrete # 59036 - Single (only) block pads with hardware, swivel straps and slotted bolts. # 59049 - Double block pads with hardware, swivel straps and slotted bolts. Vector System Lateral Stabilization For Difficult/Rocky Soils # 59287 -V-Drive System Must be used with: # 59018 - Vector for single/double block pads 3 Sq. Ft. Pad Vector System # 59271 - Vector 3 sq. ft. pad (2 required) # 59024 -Vector Lateral Hardware Kit, includes PVC adapter. Strap/Swivel Strap Connectors & slotted bolts not included. Page 4 California 9/2/03 Vector Dynamics Foundation Systems Longitudinal Component Parts List Longitudinal Stabilization Hardware Kit # 10733 - (for use with 59018 Vector System, single stack block sets only. Longitudinal struts not included) Longitudinal Stabilization Hardware Kit for Concrete # 59023 - Includes 2 beam clamps, tension brackets, nuts and bolts. (for use with #59036 & 59049, longitudinal struts not included) 3 Sq. Ft. Pad Vector Longitudinal System # 59026 - Includes 2 beam clamps, 2 tension brackets, nuts & bolts. (for use with #59271, longitudinal struts not included) Struts for Longitudinal Systems Part No. Length Pier Height # 59016 30" up to 2 Blocks # 59012 39" up to 3 Blocks # 59013 44" up to 4 Blocks # 59014 53" up to 5 Blocks # 59015 65" up to 6 Blocks PVC Adapter Bracket # 59281 - For use with Schd 40 PVC Center Compression Strut L''XY # 48612 - Single Section, 62"- 108" # 48613 - Double Section, 34"- 60" (includes short u -bolts, nuts, washers and 6 self taping screws) Page 5 California 9/2/03 Longitudinal Stabilizer Devices I The use of LSD systems on a single or multi section home replaces longitudinal anchors, stabilizer plates and .straps. The Longitudinal Stabilization Device (LSD) is used with the Vector Dynamics System to resist loads in the longitudinal direction (short dimension) of home. The number of LSD required is shown on pages 10-13. LSD C 1. Longitudinal Foundation Pad 2. Beam Clamp (2 per system) 3. Longitudinal Strut (2 per system) 4. Tie Bracket (2 per system) Combine Vector Dynamics & LSD Note: Two struts =1 L.S.D. system. Can be used on one pad or siipt on opposite ends of the home. Examples of Possible placement: (Contact TIE DOWN for placment in other Wind Zones) Wind Zone I Single Section I I I I I I I I I I I I I I I I I I I I I I I Wind Zone I Double Section 18 Ft. Max. 32 Ft. Max. Forgreater widths use triple section design. Page 6 Wind Zone I Triple Section Wind Zone I Tag Section 48 Ft. Max. California 9/2/03 50 in max. Maximum Pier Height Vector Dynamics Foundation Systems may be used on single section homes in Wind Zone I which require pier heights (from surface of Vector pads to top of concrete or metal pier) not to exceed 50 inches under one or both main rail(s). Note that a ground anchor must be used at each Vector system location where the pier height exceeds 24 inches for single section homes. On multi -section homes in Wind Zone I, an anchor must be used at each Vector System location. with pier heights above 46" with the following exception: double section homes that are 24' wide, in Wind Zone I, have a maximum pier height without anchors of 38". See page 12 for double section home high pier set instructions. 50 in max. Unequal Pier Heights, Maximum Homes with unequal pier heights are limited to 50" maximum pier height. The difference be een the taller pier and the shorter pier cannot exceed 26". Di. M ®' Page 7 California 9/2/03 Set -Up Instructions for Vector System #59018 Long. U -Bolts 1. Set Vector Pads Clear all vegatation where pads will rest. Place I long U -bolt in pad as shown. Press or ham- mer pad into the ground. 2. Set Block or piers on pads. Center foundation blocks or piers•on pads. Place pre-cut center compression member between blocks, resting on pads, centers between U -bolts as shown. 3. Outside Tension Bracket Attach outside tension bracket as shown to out- side of pads. Page 8 4. Inside brackets & straps Attach the inside tie brackets to the U -bolts over the compresion member. Attach a strap w/hook or swivel strap w/nut & bolt. Place other end of the strap over opposite I-beam & down to out- side tension bracket. Cut strap 12 - 15 inches past bracket. Attach strap & slotted bolt in bracket. Tighten strap until tight with 4-5 wraps around bolt. Repeat with opposite strap. 51eA O.'rG d 3Y m'E 3� 4 'tt�i 1. Set Vector Pads Clear all vegatation where pads will rest. Place I long U -bolt in pad as shown. Press or ham- mer pad into the ground. 2. Set Block or piers on pads. Center foundation blocks or piers•on pads. Place pre-cut center compression member between blocks, resting on pads, centers between U -bolts as shown. 3. Outside Tension Bracket Attach outside tension bracket as shown to out- side of pads. Page 8 4. Inside brackets & straps Attach the inside tie brackets to the U -bolts over the compresion member. Attach a strap w/hook or swivel strap w/nut & bolt. Place other end of the strap over opposite I-beam & down to out- side tension bracket. Cut strap 12 - 15 inches past bracket. Attach strap & slotted bolt in bracket. Tighten strap until tight with 4-5 wraps around bolt. Repeat with opposite strap. Note: L.S.D.= Longitudinal Stabilization Device C) See Page 6. o r c sy. it. pdu C Soil Classifications: Soil Bearing Capacity: Anchors Required: 34 tL max o•c.�p, . NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be 2, 3, 4A, & 46 consistent with home manufacturers' Instructions and/or state requirements. 1,000 PSF minimum 30" with 24" helix anchor (59095), 19" ctnhili7ar ninine fro,301i 4 4 iA,, s.,.. Home Length Vector Systems Required Anchors Required Per Side or 24" Pier 24+" Piers L.S.D. 0 to 72' 3 2 3 2 73' to 90' 4 3 4 2 WIND ZONE • Dynamics Systems Required for Single Section Homes Required)Vector • • it • le OAF • ' ' N;- ad :wR"" ",.� �L.. � $ tN3 Note: L.S.D.= Longitudinal Stabilization Device C) See Page 6. o r c sy. it. pdu C Soil Classifications: Soil Bearing Capacity: Anchors Required: 34 tL max o•c.�p, . NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be 2, 3, 4A, & 46 consistent with home manufacturers' Instructions and/or state requirements. 1,000 PSF minimum 30" with 24" helix anchor (59095), 19" ctnhili7ar ninine fro,301i 4 4 iA,, s.,.. Home Length Vector Systems Required Anchors Required Per Side or 24" Pier 24+" Piers L.S.D. 0 to 72' 3 2 3 2 73' to 90' 4 3 4 2 Each Vector System requires one of the following: 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) Vector Systems Required Anchors Required Per Side L.S.D. . 0to40' WIND ZONE I, SEISMIC ZONE 4 0 2 41' to 66' 3 0 Vector Dynamics Systems Required for 67' to 84' 4 0 4 `� Double Section Homesome 0 4 \ (Materials Required) ^ - h\ tOn , - \ - - do b\e sept - - -� - ampse o ` ♦ 1 \ - wit � _ - ?'l¢ ,n'=,,.m \ \ . , - - W5, F . , cc CD j CD NOTE: Vector Systems should be spaced as symmetrically as possible along the length a home. Pier spacing must be consistent with manufacturers' Instructions and/or state req n w 0 W No anchors required. For pier heights up to 46" for WIND ZONE 28'-36' wide, 38" for 24' wide. See Pg 12 for high pier instructions. 2 sq. ft. pad .Soil Classifications: 2, 3, 4A, & 4B Soil Bearing Capacity: ' 1,000 PSF minimum _ _I___ .. KI MAorrionc wail nnchnrs may be reauired by home manufacturer) Home Length Vector Systems Required Anchors Required Per Side L.S.D. . 0to40' 2 0 2 41' to 66' 3 0 3 67' to 84' 4 0 4 85' to 90' S 0 4 Each Vector System requires one of the following: 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) Note: L.S.D.= Longitudinal Stabilization Device See Page 6. NOTE: C When a pier height at Vector locations exceeds 46"; an anchor must be used on the outside wall/beam at that approximate location. NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be consistent with home manufacturers' instructions and/or state requirements. w 0 Tag or.__--- full triple z sq. n. paa z sq. n. pad A v Soil Classifications: 2; 3,4A, & 4B Soil Bearing Capacity: 1,000 PSF minimum Anchors Required': None ('Marriage wall anchors may be required by home manufacturer.) Home Length Vector Systems Required Anchors Required Per Side LSD Main TAG 0to48' 2+2 on Tag 0 2 1 49' to 71' 3+ 2 on Tag 0 2 1 72' to 84' 4 + 2 on Tag 0 2 2- 85' to 90' 5+ 2 on Tag 0 2 2 L NOTE: C When a pier height at Vector locations exceeds 46"; an anchor must be used on the outside wall/beam at that approximate location. NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be consistent with home manufacturers' instructions and/or state requirements. w 0 Tag or.__--- full triple z sq. n. paa z sq. n. pad A v Soil Classifications: 2; 3,4A, & 4B Soil Bearing Capacity: 1,000 PSF minimum Anchors Required': None ('Marriage wall anchors may be required by home manufacturer.) Home Length Vector Systems Required Anchors Required Per Side LSD Main TAG 0to48' 2+2 on Tag 0 2 1 49' to 71' 3+ 2 on Tag 0 2 1 72' to 84' 4 + 2 on Tag 0 2 2- 85' to 90' 5+ 2 on Tag 0 2 2 Each Vector System requires one of the following: 1-44 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) Lv CD L n w 0 3 03 -- - - - -- _- WIND ZONE I, SEISMIC ZONE 4 (High Pier Sets) ' Vector Dynamics Systems Required for Double Section Homes (High Pier Sets with Diagonal Ties) _ ' "' " home double Sect,o� I i I NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be consistent with home manufacturers' instructions and/or state requirements. WIND ZONE I Max. Height UnitWIdth See Page 7 Co N rA-mng % sq. IL padr Min. 0 to 48' 2 2 2 49' to 71' 3 3 3 72' to 84' 4 4 4 85' to 90' 5 5 4 Soil Classifications: 2, 3, 4A, & 4B Soil Bearing Capacity: 1,000 PSF minimum Anchors Required': 30" with 2-4" helix anchor (59095), 12" stabilizer plates (59292)1-1/4" frame be with connector Each Vector System requires one of the following: 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) WIND ZONE 11, SEISMIC ZONE 4 (Hurricane) Vector Dynamics Systems Required for I , Single Section Homes - (High Pier Sets with Diagonal Ties) C%on hors ems• u�delines 1e Seo ectoc sY arua, 9 �{ a 7� to sP g' meot s a�jation cn A., .r EXampsho`�s gn,st be to o Nludssrat�dspac%n9 I — oandstioa Pa `., `' `` — — = _ i " _ — ` iia d•: tc "D tp rn w WIND ZONE li (not to scale) RN I ", ,.,s t Soil Classifications: Soil Bearing Capacity: Anchors Required*: 2,3, 4A & 46 1,000 PSF minimum 30' with 4° helix anchor (59095), 1-1/4° vertical ties w/4725 lbs. min. breaking strength. Home Length Vector Systems Required Anchors Equired LSD per side 0 to 48' 3 5 2 49' to 60' 5 6 2 61" to 72' 6 7 2 73' to 84' 7 8 2 85' to 90' 8 9 2 NOTE: Vector Systems should be spaced as symmetrically as possible along the length of the home. Pier spacing must be consistent with home manufacturers' instructions and/or state requirements. Maximum allowable working drag load for the Vector System with steel compression strut is 4,000 lbs. per the K2 Engineering test report. T �Each Vector System requires one of the following: 2 sq. ft. pad 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) �Q CD ItE WIND ZONE II, SEISMIC ZONE 4 home ems. � . e,mes l - =�. Vector Dynamics Systems Required for _ - - " " - X%oln s ste v%d _ ;% . Double Section Homes - ' - - oub\e fvecttio� manna --- 01 ` " "gen e to boand s NOTE: Vector Systems should be spaced as symmetrically as possible along the length i home. Pier spacing must be consistent with manufacturers' instructions and/or state req Maximum allowable working drag load for tl System with steel compression strut is 4,001 the K2 Engineering test report. dgon gad'- �fW9 a WIND ZONE II (not to scale) \2 sq. ft. pad/ son tseanng Lapaciry: i,uuu rar nunimum Anchors Required': 30' with 4' helix anchor (59095), 1-1/4' vertical ties w/4725 lbs. min. breaking strength. Home Length Anchors Equired per side Vector Systems Required LSD 0 to 48' 4 4 3 49' to 60' 5 5 3 61" to 72' 6 6 3 73' to 84' 7 7 4 85' to 90' 8 8 4 Each Vector System requires one of the following: 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) W NOTE: n When a pier height at Vector locations exceeds 46", an 4 anchor must be used on the outside wall/beam at that _ approximate location. NOTE: Vector Systems should be spaced as ; m symmetrically as possible.along the length of -the home. Pier spacing must be consistent with -home manufacturers' instructions and/or state requirements. Tag or__-,- Soil Classifications: 2, 3, 4A, & 4B full triple. ` Soil Bearing Capacity: 1,000 PSF'minimum Anchors Required': 3/4" x 30" with 4 helix anchor (59095) 1-1/4" vertical ties w//4725 lbs. min. breaking strength. Home -Length Vector Systems Required Anchors Required Per Side LSD Main TAG 0to48' WIND ZONE • i 2 1 49' -to 71' 4+ 2 on Tag Vector Dynamics Systems Required for e 72'to84' 4+3onTag 7 Triple Section Homes 2 o ,ste se 5+ 3 on Tag 8 3 (Materia \ject0t. • ' _y 0. d'i �® � �i ®1�1 FWK �.2✓+n' �+, ,P ARG Ira ANN OW r "WAy;,�y*•r. NOTE: n When a pier height at Vector locations exceeds 46", an 4 anchor must be used on the outside wall/beam at that _ approximate location. NOTE: Vector Systems should be spaced as ; m symmetrically as possible.along the length of -the home. Pier spacing must be consistent with -home manufacturers' instructions and/or state requirements. Tag or__-,- Soil Classifications: 2, 3, 4A, & 4B full triple. ` Soil Bearing Capacity: 1,000 PSF'minimum Anchors Required': 3/4" x 30" with 4 helix anchor (59095) 1-1/4" vertical ties w//4725 lbs. min. breaking strength. Home -Length Vector Systems Required Anchors Required Per Side LSD Main TAG 0to48' 3+2 on Tag 4 2 1 49' -to 71' 4+ 2 on Tag 6 3 2 72'to84' 4+3onTag 7 3 2 85' to 90' 5+ 3 on Tag 8 3 2 ach Vector System requires one of the following: C) 1-4x4 or 2-2x4's pressure treated wood compression member, Schedule 40 PVC Pipe or 1 adjustable steel compression (see parts list) A m 2 sq. ft. pad 2 sq. ft. pad Vector Dynamics . Metal Pier & V -Drive Installation 6111111., METAL PIER FOUNDATIONS For metal piers, place the piers in the center of the Vector pads. Set the single 4x4 or two 2x4's through the piers, centered in the U - bolts. Outside Tension brackets attach the same, Inside tie brackets mount 'upside down' as shown in drawing. Metal piers using the Vector System can only be used on level ground sets. Conventional pier adjusters must be placed under beam with upturned edge directed towards the outside of the home Pier spacing must be consistent with home manufacturers' installation instructions and/or state requirements. To cut lumber (2 - 2x4s or 1 - 4x4 per, or 1 adjustable steel commpression member, part #59043 Vector system) for the center com- pression section, when using METAL PIER STANDS, measure center to center frame distance and add 16'. Optional Moisture Termite Shield may be required in certain regions. ALL WOOD MUST BE PRESSURE TREATED, GROUND CONTACT RATED. Tip: Pre-cut your lumber and mark as to brand or model of homes you will be installing. If frame widths are the same, the pre-cut boards will also be the same length in each Vector set-up. V Drive for rocky soil V -Drive anchors are used only in Zone 1. single section homes.. V -Drive anchors are used only in Zone I, single section homes in areas where rocky soil conditions do not allow helix style anchors to be installed. Vector Systems are set following the general set up instructions provided. With the V -Drive anchor, the short 2x4 boards used with the outside tension brackets are discarded. In place of the short 2x4's, a longer 2x4 is used as per the diagram above. This 2x4 board should extend from the base of the Vector pier set to 5 inches from the side wall of the home. Place the V -Drive head over the end of the longer board. Using a heavy hammer or electric hammer gun, drive the three V -Drive anchor rods through the V -Drive heads at an angle of approximately 45 degrees under the home. The rods must come to a complete stop on the V -Drive. head. Attach a strap with hook or buckle to the frame and attach to the V -Drive head with a slotted bol ut the strap end about 12 to 15 inches past the anchor head to allow at least four or five wraps around the slotted bolt. ont' a tighte 'ng strap until all slack is out and strap is tight. Page 16 California 9/2/03 VECTOR DYNAMICS INSTALLATION DESIGN INSTRUCTIONS Vector Dynamic Foundation Systems may be used only on homes set on soils classified as Class 2, 3, 4A and 4B as described in the table below: SOIL CLASSIFICATIONS Soil Class Types of Soils Blow Count (ASTM Soil Test Probe (1) D2586) Torque Value (2) 1 Sound hard rock...... NA NA Very dense and/or 40 -up More than 550 lbs - in. cemented sands, coarse 2 gravel and cobbles, preloaded silts, clays, and corals Medium -dense coarse 24-39 350-549 lbs - in. 3 sands, sandy gravels, very stiff silts and clays 4A Loose to medium dense 14-23 275-349 lbs - in. sands, firm to stiff clays 4B and silts, alluvian fill 175-275 lbs - in Peat, organic silts, 0-44 175 lbs - in. 5 inundated silts, loose fine and lower sand, alluvium, loess, varied clays, fill, fly ash. (1) The purpose of the soil test probe is to gauge the strength of the soil below the surface and near the anchor's helical plate. The strength of the soil is estimated in terms of its resistance to penetration (flow) under load by means of the torque probe and is measured in Ib -in. The test probe has a helix on it. The overall length of the helical Section is 10.75 in.; the major diameter is 1.25 in.; the minor diameter is 0.81 in.; the pitch is 1.75 in. The shaft must be of suitable length for anchor depth. (2) A measure synonymous with moment of a force when distributed around the shaft of the test probe. Vector Foundation Pads Equivalent to Footer Pads* Footer Size: Footer Size: _ 16x16 = 256 sq. in. - 20x20 = 400 sq. in. or 16x18 = 288 sq. in. or 17x25=425 sq. in. EQUALS EQUALS 2 -Vector Pads # 59275 1 -Vector Pad # 59271 288 sq. in. or 432 sq. in. 1 Vector Pad # 59130 Vector Pad(s) exceed the surface area required when used as the equivalent liste bove. 'Foundations in soil with a bearing capacity of less than 1,000 PSF must be designed by a Registered Professional Engineer ar with site conditons N C e Page 17 California Vector Dynamics System for Concrete Applications Instructions These instructions are an addendum to the standard Vector Dynamics instructions. Read and follow all applicable instructions and guidelines in the Vector instructions and home Installation manual. The Vector system for concrete pads applies to concrete footers, runners and slabs. Minimum size of concrete per Vector pier is 24"x24" x 4" or 18" round (min) x 10" deep. The bottom of footers must be below the frost line or a minimum of 4" below finished grade whichever is greater. Concrete must be sufficiently cured and set to accommodate an anchor bolt to its' full load resistance. 1. Determine location of pier sets where the Vector systems will. be located. 2. Place one Vector concrete pad (galv. metal) on the concrete where the pier will be located, centered under the I-beam of the home. Place the upturned edge towards the center of the home and directed to the opposite Vector pier. Do the same for the opposite Vector pier. 3.. Measure the distance between the two Vector system pads at the base where the Vector pad meets the concrete. Cut two ground treated 2x4's or Schedule 40 PVC pipe, or 1 adjustable steel commpression member, part #59043 this length and place between the piers as shown. 4. Place a long u -bolt under the 2x4's and through the holes of the Vector pad as shown. 5. Place the concrete pier blocks on the Vector pad. Center the blocks under the frame. The upturned edge end of the Vector pads should be up against the inside of the pier blocks. 6. Build vector piers but do not wedge at this time. 7. Using a concrete drill bit, drill two holes on each side into the concrete using the holes in _the Vector pad as a guide. Drill the 3/8" diameter holes 3 inches deep. 8. Place an outside tension bracket on the Vector pad -as shown in Illustration one. Line up the holes in the bracket, Vector pad and concrete pad. Illustration One of a Single Section Set -Up Vector pe for concrete footer Page 18 California Wood Cap and wedge Outside Tension Bracket Wedge Bolt Li aPa� KO ,. Vector Dynamics System for Concrete Applications Instructions 9. Put a washer and nut on one of the 3/8" x 3-3/4" wedge anchors. The nut should be screwed on enough to have 1 or 2 threads showing on the top of the bolt. Place the wedge end of the bolt into one of the holes, going through the outside tension bracket, metal Vector pad and into the concrete. 10. Using a hammer, tap the wedge bolt into the hole. Maximum height for expansion bolt above concrete is 2". 11. Repeat for the other hole in the "outside tension bracket and the two holes on the other Vector system pier seta 12. Place an inside tie bracket over the u -bolt so that the lip of the bracket is between the Vector plate and concrete blocks. Place washers and nuts on each U -bolt. Do not tighten yet. 13. Attach a strap with hook or crimp seal to the inside tie bracket, with sufficient length to go over the opposite pier and down to the outside tension bracket; plus 12 inches for wrapping the slotted bolt. Repeat for the opposite side. 14. Tighten inside u -bolts at this time. ` 15. Use the outside tension brackets to remove any space between the outside tension brackets, concrete blocks and the inside edge of the Vector pad, by tapping the brackets with a hammer. ' Wedge the pier set at this time. 16. Using a 9/16" socket wrench, tighten all of the wedge/anchor bolts,'securing the outside tension bracket and Vector pad.to the concrete. 17. Using a slotted bolt in the outside tension brackets, insert strap through slotted bolt with end of strap aligned with outside edge of bolt. Turn slotted bolt until straps are tight using at least five turns on the slotted bolts. Illustration Tv Inside Tie Bracket Compressii boards of PVC Pipe a 1 Nage 19 . . canTorma id e e v - Z1/2/03 P'10 -INS PEgT f EP:ORT i-•♦ OWNER 6,, LOCATION: y��f ��/� zl-c/,, CONTRACTOR: DATE: A.P. #„G - ,p L L �/�,� / ZONING: PRE-INSPE-nON FOR:__ (�- �C M / /Yt DATE TO INSPECTOR PERMIT HLSTORY:( ) NONE ( )AS, FOLLOWS: r BUmmm, IIVSPECTOR's REPORT Building Description: Commercial0sage: Residential/## of Units: Currendy Occupied AbandonedlVacant Electric: Yes V No Electric currently On Off Condition of Electric Gas: Natural Propane_ None Currently On Off Obvious Problems: Sanitation: Plumbing Working V' WellWorking_ Pe OlL& Potable Water Obvious SewageProblems M ACTION RECOMMENDED: ISSUE: HOLD FOR Inspector. Date Sketch buildings on reverse and indicate location on property. 'JOU( • , OF BUTTE - DEPARTMENT OF € EVELOPMEN ' SERVICES - BUILDONG DIVISION County Centel- Drive . Crovi€€e, California 95955 • Telephone (530) 538-7 (Rev. 12196) APPLICATION AND PERMIT 03 N• ASSESSOR AR N ER ----. $ m ' La6.tILDIY`YG PERMIT r $ OWNEA "? AMOUNT RECEIVED $ 3 • �� SQ. Fr. OCC. BUILDING VALUATION /(/ 31 D3 . OW 65NUNG ADD 5 , ' CO +OA'S NAME CO RS ltiil<, ADD U ' co TtoNtENcsi LENDER'S tMfUNGAMBEW Fireplace . Total Valuation $ ARCWECT OR EMNEM uc ss rio• Pilin Fee 20.0 ARONRECT OR ENMWESIS MUMADDRESS Permit Fee , Pian Checking -Fee Energy Plan Plan Cheeld ig Fee L � PERMIT FEE S 3 wTNo. suaorvLsroNSNAta P � PLUMBING PERMIT Firing Fee 20.0 Each Trap 7,00 USEOFSTRUCTURE - Solar or heat pump water heater 29.00 SF ❑ Duplex ❑ Mobilehome A( Water piping 15.00 (R; —06er sir Each gas water heater or vent 15.00 TYPE OF WORK Cies nstem 1 -fi Outlets;Outlets;15.00 SC.0 ❑ Other 0,— iii Now ❑ AddN Rritodel ❑ 7jt/; Building sewer 15.00 Describe Work: AIX Mobile Home S G W @20.00 PERMIT FEE CM. (10 ELECTRICAL PERMIT Firing Fee 20.0 Main Service ( 'w'aAD"Ris=ss ) 23.00 PERMIT FEE Pall? $ SRA $ SHERIFF $ OTHER $ AMOUNT RECEIVED $ 3 • �� _3(a DATE RECEIVED. I '),I 31 D3 39 39 Mah..SeWIM d 260A 11`0 toaaA 46.00 NEW CONST.atNE111Ne OCCup. Sn OR ADONS. 8 ACC. etas 3.SLfP7. yd:� U A Ez Occuo- i Mier Olt —nAEB I I I ZI Temporary Service 1 23.00 Mobile Home Facilities 120.00 (Ursa. Wiring 1 29.00 PERMIT FEE 14 MECHANICAL PERUFT Firin4 Fee 20.0 PERMIT FER 1 $ Mobile Home Installation Fee Lzs Energy Inspection Fee Is cols:. TYPE TOTAL FEE $ 3 HAZ 1 R FEES MF1 I FLOOD I COF I PARCEL 1--1101 ,NO 0 This permit Is hereby issued under the applicable provislor of the Butte County Code and/or Resolutions to do wo indicated above for which fees have been paid. BY Date AP 64-66-21 Ehrlicjh Ct., eat of Skyway, Magalia 64-66-21 Henr LoehrZ / '/�W/ Ehrlich app 3 O'S.of M galia contr: Hess Backhoe Serv., Paradise Permit #3950-7 P,ELu.til. ,MH) ELEC. _�—rQ 7 S %if)L9 STIPPORT STRUCTURE REQ, //COMPACTION TEST REQ.jj `(-W4 64-66-21 contr: Richaf"d Marcntte, Paradise Permit #4650-79B,E(new pri.det.garage) �•%l��7 4-66-21 Cdntr: Hilton's MH, Magalia P rmit ##5339-79MHI Is ud ---oL < �� 64-66-21 contra Anderson Awwnin g, Chico 5 Permit #5911-79B(new awning/MH) 64-66-21 Henry Loehr 6414 Ehrlich'Ct., Magalia contr • Bernies MHS,.errv. , Paradise Permit ��1042-82B�neW awn g MPH y� 064-66-0-021 99-0477 P BILLET, William �Ll� , X114 Ehrlich, Magalia pg yard line) Del Johnson Htg j OW Ad ri J.if ski jkPj Of it qq yW ,;;, .� ti t.. � {`�f�+ � Il l� i t Ir• i, � I � f tf��� !i N i "ri} �:k. �; 4V bit P t• a�i. ���' 'E 1 t!• f� 1� 7 I � 'I I ( I i'l "1 q +i.' r�i` Il�fi �I' 1 S imp 1 "lint I it 15. - n r I, i ,i I, 1.1 ' F ,�� �5�1 �y ?-�{ �: �•, }!eup � , i i Wig Q 1�: � '' � ,� ►� Lrf, Inv- eJ ''{) + � �^L!} I l ..r� al tl r I, A Awl 14o Qr i1 4J1 Pll� I ZI I1�1 r l � � � ,.��� � ' }'S� ��� }'� ` � r{ �: NII `� � ' ! ,' i. ' ' • , 1' �E.' �`',( dF. (I.:YD; ��i`�. t (t�� � .tt lop 0. 'I't f --I �� �� � � #,1{ I� 'r � � � ? 4 1114 � ;jf t>• :Y' I 4 � ► : R{ , � ; ; ! t , �i i ,, f l �I�� r � ;j -42 z! t I loop Ili tf5 Olt Ell t JS Ell I • • � I 064766-0-021 99-0477 P BILLET, William - 6414 Ehrlich, Magalia (lpg yard .line) Del Johnson Ht Jr OK OFFICE COPY Address //r GAS Date Meter B ELECTRIC.- Date Meter By COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER ZONING BUILDING PERMIT OWNER + TELEPHONE SO. FT. OCC. BUILDING VALUATION OWNERS MAIUNG ADDRESS In t ri/l o , u f CONTRACTORS NAME TELEPHONE CONTRACTORS MAILING ADDRfSS ri ( CONSTRUCTION LENDER Fireplace LENDERS MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDINGADDRESS It r Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Filing Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome & Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK / New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation C3 Other ❑ Describe Work: _rN S '62 f4 1 % J �I Al -( Gas piping stem 1 - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G W @20.00 PERMIT FEE $ A Iq, •-o ELECTRICAL PERMIT Fling Fee 20.00 Main Service 20.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION 1 hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.' r� License Class(- �:Q �• t/ 3 Lic. No. - 73 /5G 7f OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service Y To I000A 46.00so NEW CONST. ONE NG OCCUP. E OR AODNS. ( a ACC. BLDS. SO 3.5Q FT. NON g61D. MULTI-ORANCH URQUITS TLET @7.50 POWER APPARATUS a SINGLE OUTLET CIR. Ex. Occup. OUTLET OR FDCTURES @ 100 BPL FIXED Ex. Occup. O. RM OR, 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the —/ performance of the work for which this permit is issued. M I have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier 4r`f 5!�/.t'-.G'=✓=�G['�' to Policy Number `j/ ,r-t!) (The above sections need not be completed If the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. / X .,elf Date � �S" _ Signature of Applicant - ❑ Owner [D'Contractor ❑ Agent An OSHA permit is required for excavations over 60" deep and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE S Mobile Home Installation Fee $ Energy Inspection Fee $ occ CONST. TYPE TOTAL FEE $ 3 5Q +� HAz. o. FEES IMP I FLOOD I CDF PARCEL PD HO ISSU This permit is hereby issued under of the Butte County Code and/or indicated above for which fees have By 12 .{r t` EXPIRES ON 3" the applicable provisions Resolutions to do work been paid. Date / 5- .2 0 e O ate Receipt No. 7PERMIT WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, Califernia 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT 0� ASSESSOR PARCEL NUMBER ZONING 2 BUILDING PERMIT OWNER o r I) a ; 115- TELEPHONE SO. FT. OCC. BUILDING VALUATION .OWNER'S MAUI ADDRESS E � r l t � l4- �Y � A CA- /t] (RACTOA'S CO NAME Q % TELEPHONE L 1 W CONTRACTORS MAILING ADDONSS Zd D / O— E CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ BUILDING ADDRESS {� - Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome B'Other SPECIFY Each Trap 7.00 Solar or heat pump water heater 23.00 Water piping 15.00 Each gas water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation Other ❑ Describe Work: 1 /V $ 4Q /Z �� /z r� i 11/ -L / Gas piping system t - 5 outlets 15.00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE S , �� ELECTRICAL PERMIT Fling Fee 20.00 Main Service zo q OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect.POSINGLE License ClassC ZO C 3 Lic. No. -3 73,1L7 OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: CarrierL'i64vL�r Go Main Service 200A TO 1000A 46.00 NEW CONST. OW EWNG OCCUP. OR ADDNS. ( a ACC. BLOS. SO 3.5¢x. N"ONRESIo MULTI -OUTLET @7,50 WER APPARATUS 8 OUTLET CIR. Ex. Occup. OUTLET OR FIXTURES 2001.00 SAL o .50 Ex. Occup. OFlxur�rs �'') AE 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt: $ Policy Number 544 /.�" D (The above sections need not be completed ,if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers'. compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall fort with comply wi those provisions. s Date �s 7 Signature of licant - ❑ Owner Com ntrsctor ❑ Agent An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ 3 5 0_� D FEES IMP I FLOOD I COF PARCEL PD HD ISSUE, This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees_ have been paid. By Uy t Date 33 15- 9'9 PERMIT EXPIRES N -3-- 5"— .Z G �' Q Date No. oZ S e_17 rT .D.S.•B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT I% PERMIT NO. 1042-82B PERMIT EXPIRES OWNER Henry Loehr CONTR. Bernies MH Serv., Paradise ASSESSOR PARCEL 64-66-21., LOCATION .6414 Ehrlich -Ct., Magalia r441 JOBVFIALED (Date) Signature 19 Temp. Power Pole Called PG&E Temp. Elec. Service, Called PG&E_ Temp. Gas Service /y Cal led PG&E _ JOBVFIALED (Date) Signature 19 V = OK O = Not OK Not Applicable MOBILEHOMES MISCELLANEOUS = Not Ready Date MOBILEMOME UTILITIES (Plans) OK except N's Date DEkK!.,,L,0VERS, CARPORTS, ETC. (Plans) OK except N's 1. Zoning Requirements—Setbacks—Easements 1• equirements—Setbacks—Easements 2. Soils; Special MH Support—Sketch Footings; Size—Depth—Spacing—Connectors 3. Sewer; Location—Test—Fall-C/O—Concrete 3. Decks; Girders and/or Joists—Decking—Bracing-Stairs—Rails 4. Water; Location—Test—Easement Needed (Sketch) 4.,0(pown.; Posts—Beams—Rftrs.—Connec.—Shthg.—Rig.—Bracing 5. Electricity; Local ion—Clearances—Grnd.—/ / Amp—Concrete 5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures 6. Gas; Location—Test—Wrap:/ /"L"ft./ /"Nat. or/ /"L"ft./ /"LPG 6. rports; Windows—Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI to mrd= Date Card -BI Date Card -BI Date Card -BI _ a and -BI Date Date MOBILEHOME INSTALLATION (Plans) OK except N's 1. Zoning Requirements—Setbacks—Easements Date _ POOLS (Plan) '6K except N's 1 • Setbacks—Easements 2. Footings; Size—Spacing—Marriage Line 2. Soils; Compaction—Structure Stability 3. Gas; MH Test—Demand—Valve—Connector 4. Electricity; MH Test—Crossovers—Breakers—Clearances 3. Pool Structure; Steel—Connections—Thickness—Dead Men—Lining 4, Elec.; Receptacles and Lighting; Distances—GFI 5. Drain; MH Test—Fall—Flex Connector 5. Elec.; Pool Lighting; 15 volts—GFI 6. Water; MH Test—Regulator—Connector 6. Elec.; Enclosures; Conduit Entries—Terminals—Listed 7. Water and Sewer Connected—C/0 to Grade—HD Approval 7• Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghtg. Boxes—Enclosures—Panel boards—Ins. to Main in Conduit 9. Exits; Insp.—Sketch 10. Carl. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test—Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date = OK = Not OK , = Not Applicable = Not Ready RESIDENTIAL (Single and Duplex) Date UNDERFLOOR Plans OK exce' t H's Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage-3rd'story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 51. 52. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 55. Shear Walls; Nailing -Bolts 9. Gas Pipe; Size -Anchors 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Card -BI Date Card -BI Date Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FINAL (Plans) OK except N's 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 57. 58. 59. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor -Ducts -Meeh. Protection Bedroom Exiting 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except q's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 70. 71. Plb., Elec. & Mech. Equip. Listed for Location Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 22. Size Boxes & No. of Conductors -Stapled 23. Romex Installed Close to Edge of Studs & C.J. 24. Equip. Ground made up w/Mech. Fasteners -Bond Gas &Water 72. Insulation -Foam -Looked in Attic E) Yes 25. 2 Appliance Circuits in Kitchen &Conductor Size 73. Guard Rails &Deck Construction -Post Caps _ 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or At, Insulated Neutral []Yes El No 75. Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters Dyes ❑No 28. Service -Riser Conductors & Ground -Main Disconnect 76. 77, Stucco; Brown -Finish A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 29. 30. Equip. Clearances; Panels-Motors-Mech. Equip. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B I Date Card -BI Date 81. Ventilation throughout House Card B -I Date Card -BI Date 82. Glass Protection Date MECHANICAL (Permit) OK except q's 83. _ Corrections from Previous Inspections 84. Gas Test -Meters Tagged; Gas -Electric 31. A.C. Ducts; Insulation & Support 85. Water & Sewer Connected -C/O to Grade -HD Approval _ 32. 33. Vent Fan; Exhaust above Insulation Condensate Drain & Overflow; Size & Grade 86. Energy Compliance Certificate -Other Certificates 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic - Card -BI Date Card -BI Date Card -BI _- _Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except q's 36. Sills; Proper Material & Anchors Comments at Final: 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound _ _ 38. 39. 40. 41. Bearing Walls over Girders & Floor Nailing Draft Stop in Walls (rat proof) Fire Stops; Furred Ceilings -Stairs -Chases -Tub Header & Beam -Size & Bearing 42. 43. 44. 45. 46. Hangers -Post Caps -Anchors -Connectors Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthnq.-Rfnp. Fireplace Ties or Type A Flue -Fireplace Throat Attic Access: Size & Romex Protection -Draft Stop -Ins. Baffles Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framing (NOTE:Anentrymust be made each time youvisit jobsite) COUNTY OF BUTTE - DEPART, F PUBLIC WORKS 7 County Center Drive - Oroville;+':.alffarAia 95965 - Telephone 916/534-45 APPLICATION AND PERMIT x PER IT NO. /D t1 ASSESSOR PARCEL Nr R 6 _ Z/ Y (/Q_ ZONING UILDING PERMIT 0 WN F,4R PQU�L/ TELEPHONE S . FT. OCC BUILDING VAL ATION V 00 OWNER'S MAIL NG ADDRESS �Q1NJ�TRACNAME U� TSE NE 407 CNSRACTO(JJ- MAIL DDRESS Jr 5e) DQT� C // �[�. (/T Fiteplace CONSTRUCTION LENDER UNKNOWN Total Valuation 1 $ 00 Fee $ 10.00 LENDER'S MAILING ADDRESS'Filing Permit Fee $ , ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 'S Penalty $ ARCHITECT OR ENGINE R' AILING ADDRESS Permit fee $ 5q,2 BUIL,Dp ADD /(// 300 / S PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. SUBDIVISION NAMEPARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF Q Duplex[]Mobilehome Other SPECIFY Building sewer Lawn sprinkler system 5.00 1-11 TYPE OF WORK New ❑ AdditionEKFiemodeI Utilities ❑ Installation❑ Other ❑ Describe work: �l/�/V Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100 AMP OR00V OR LESS5.00 Main service EA. AOD'L 100 AMP 2.50 NEW CONST. / DWELLING OCCUP.51 OR ADDNS. \ ACC. BLDGS. 20 sq ft CONTRACTORS LICENSE LAW I declare nder penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and y license is in ful r e and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CON5TR I.Ou LET NON.RESID BRANCH CIRC ITS 2.50 ea NEW CON ST R. ( POWER APPARATUS 6) NON-RESID. SINGLE OUTLET CIR. 50 @ 25¢ Ex. OCCUp�O TS OR FIXTURES BAL@1 IXED IXED APPLES, OR EX. OCCUp.(OUT LETS (RESID.) EA. 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 7.50 Permit Fee $ Contractor MECHANICAL PERMIT FiIingFee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. Ei;,,I-have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabillt'es, judgments, sts n nses which may in any way accrue agains d County ' se e e gr nting of this per . X Date �� _�Z Signature of Applicant — r Contractor Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- structures over 3 stories inheight. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ Occup, GROUP �� TYPE F cONbT. -,�`/// PA L (/ PD HD ISSUE c/ This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECT OF PUBLIC B y PE IT EXPfRES Date_. the applicable provi- resolutions to do fees have been paid. WORKS JS -g iOeipt DateE-D.P.W., .J Lion,Cof No. [% (C/� I/ YELLOW -ASSESSOR, PINK- NSPECTOR, GOLDENROD -APPLICANT PERMIT NO. ALL-IL 7 9B : ..... � PERMIT EXPIRES 9/X7/Yd Henry Loehr? Ir"OWNER CONTR. Anderson Awning & Mh Serv., Chico 64-66-21 LOCATION (A.P. ) 1614 Ehrlich Ct., lot 138, dzr,,�`�.. fi. .r Temp. Power Pole Called PG&E Temp. Elec. Serv. Called PG&E Temp. Gas Serv. Called PG&E JOB FINAL (D e) z r (Signature) nr �i t Footings Footing ELECT CAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE S RINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh 4ECHANICAL Grd. Fault Prot. Scratch Heatino Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UTILITIES Elec. Service Elec. Pedestal Water Piping Sewer Gas Piping MQ016EMOLAE INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUI Lp�ft BUILDING (Cont'd) PLU ING Setback /D—/0r Firewall Soil Piping Forms Parapets 1st Floor Mal Bidg. Restroom Finish 2nd Floor Footings 60-149 -7 Windows 3rd Floor Stemwall Sidina To out Slab Roof Sheathing Water Piping Piers Roofing - 7 ® Sewer Garage Fdn. Vents Fixtures Footings Stemwall Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for phsically handica ed Conformance of ex. structure Appliances Gas PI in &Test Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footing ELECT CAL Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE S RINKLERS Motors Framing Test Water Htr. Stucco Final Subpanels Mesh 4ECHANICAL Grd. Fault Prot. Scratch Heatino Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UTILITIES Elec. Service Elec. Pedestal Water Piping Sewer Gas Piping MQ016EMOLAE INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE REMARKS OR CORRECTIONS (NOTE: An entry must be made on this form each time you visit the job site.) COU4NTY OF BUTTE. --z-DEPARTMENT OF PUBLIC WORKS 7 County Center Drive .'•- OroviIIe, California 95965 Telephone: 534-4541 APPLICATION AND PERMIT Ane,i� authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date ZZ S / Signature of Permitee or Agent Receipt No. 29W20 White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR O,F,PUBLIC WORKS By Date B(11/ding permit expires Date�7 —,? 0 BUILDING Owner G W) N L40-9-9 SQ. FT. OCC.,BUILDING VALUATION -35o y Mailing Address Telephone No. Contractor rnVD A) /q -W AI(A) Mailing Address Pd /zoo Lqv Fireplace Total Valuation �'6 c �T C� / 0 CA_ Tele hon o t�2,-� ) Permit Fee Building Address I L4 L t44?J_ACH CT Plan Checking Fee&/or Penalty Permit Fee PLUMBING No. @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 LOT If 7> Repair drainage or vent piping 1.50 i p A. P. o. `'[ "Cp "�jl oning & Planning Water piping 1.50 Each gas water heater or vent 1.50 F s I vvc". Sei ion Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA P Ing 'ng -7 sans -Marcel Declaration Parcel Ma P 60' R/W provements Improvements Each additional outlet .30 Building sewer 5.00 Bld Plans Recd I Parcel Approval k"" Plans Appr val Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER permit Fee $ $ A(,UmAx2 e k ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service 10011 OR 0 AMP ORSLESS 5.00 Single Family ❑ Duplex ❑ Mobil Home ffJ Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER 800V 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW LING O OR ADDNST % ACCLBL GS CCUP. S) 20sq ft CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: 4A. -Jo C RSD /' zf Lu.viiu� �1-ts1�/F NEW CONRESt D. BRANCH TLET CIRCUITS) NON•R ESI D. ( BRANCH CIRCUITS) 2.50ea NEW CONST R. POWER APPARATUS B NON•RESID. SINGLE OUTLET CIR. EX. OCcuo(OUTLETS OR FIXTIIRES) 5BDAL2; FIXED APPLNS. OR Ex. Occup. OUTLETS (RESID.) EA) 2.00 Temporary service 10.00 / Mobile Home Facilities 15.00 License No. 3 79197 Classification C -C Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ©Xfiave placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any personin any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE is -2g a authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date ZZ S / Signature of Permitee or Agent Receipt No. 29W20 White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR O,F,PUBLIC WORKS By Date B(11/ding permit expires Date�7 —,? 0 ;r i h Y PERMIT NQ., 4650-79B,E ' PERMIT EXPIRES OWNER Henry Loehr ,,CONTR. Richard Marcotte, Paradise 64-66-21 LOCATION (A.P. ) W/S Ehrlich Ct., app.300'S.of Skyway, Magali< i.;. �f A emp. Power Pole " Called PG&E Temp. Elea Serv. Called PG&E Temp. Gas Serv. r� Called PG&E A JOB FINALED (Dates)' ( ign ture) i� COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) PLUMBING Setback r C Firewall Soil Piping Forms Parapets 1st Floor Main Bldg. Restroom Finish 2nd Floor Footings Windows 3rd Floor Stemwall Siding To out Slab Roof Sheathing Water Piping Piers Roofing Sewer Garage Fdn. Vents Fixtures Footings C/` Stemwal I Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for physically handica ed Conformance of ex. structure Appliances Gas PipingTest Temp. Gas Slab Final Sanitation Patio FIREPLACE Final Footings Footinq ELECTRICAL Masonry Walls Throat Rou h Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLERS Motors FramingTest Water Htr. %Stucco Final Sub anels " Mesh MECHANICAL Gird. Fault Prot. Scratch �-~ "7 9n Heating Service Brown Cooling Temp. Pole Finish Ducts Underground Interior Lath Ventilation Permanent Door Closer Final Final MOBILEHOME UTILITIES ------------------ Elec_ Service Elec. Pedestal Water Piping Sewer Gas Piping OBILEHOME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity Water Piping Drainage Gas Piping DATE I REMARKS OR CORRECTIONS n (NOTE: An entry must be made on this form each time you visit the job site.) JCOUNTY OF BUTTE — DEPykRTMENT OF PUBLIC WORKS 7 County Center Driver — ,Oroville, California 95965 Tel dphone: 534-4541 APPLICATION AND PERMIT Owner "lye Cf'!z"/�/1✓ Mailing Address 11/G1' Telephone No. _ BUILDING al SQ. FT. OCC. BUILDING VA UATION J 2. g �j Li dS • O'er Contractor C, jw1, /�,q/ZCO % j E NEW CONSTR BRANCOUTL T NON-RESID, � BRANCH CIRCUITS) 2.50ea Mailing Address �G' ���z Fireplace Ex. Occu FIXED APPLNS. OR p• OUTLETS (RESID,) EA) 2.00 Total Valuation j(o�Q. 0_0 Mobile Home Facilities 15.00 TTlephone No d'77-7Sk2- Permit Fee c6C7 Building Address �Qf �-- 24c 24'13,0Plan Checking Fee&/or Penalty $ /3 $ Permit Fee P, 140 o f'4"/3� PLUMBING No. @ FEE /_, 4L4i/ S 6#k 1- GT- .4 OT 31 0/ PERMIT FILING FEE $3.00 Each Trap 1.50 .siC`f�6(f A- /LIA-LrgLl Repair drainage or vent piping 1.50 // A. P. No. Zoninb &Planning Water piping 1.50 Each gas water heater or vent 1.50 Fs 11 W. Sa on Fire Dept. Fire Zone Use Permit Gas piping system 1 -5 outlets 1.50 EQA Parking Plans ParcelEach Declaration I Parcel Map 0' R/W I Improvements additional outlet .30 Building sewer 5.00 Bldg. Plo eced Parcel roval Pla pproval Lawn sprinkler system 2.00 NEW ADDITION ❑ UTILITIES ❑ OTHER ❑ P $ ermlt Fee J7�/ Ate % RfL/C{ ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 5 •0d Main service 600V OR LESS ,--�/ 100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil Home Others LTJ Main service EA. ADD -L 100 AMP 2.50 Mainservice OVER 600V 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 (, CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name st le of y lyxeea 7 n NEW CONSTR BRANCOUTL T NON-RESID, � BRANCH CIRCUITS) 2.50ea NEW CONST. POWER APPARATUS 8 NON.R RESID. (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES g L@; Ex. Occu FIXED APPLNS. OR p• OUTLETS (RESID,) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No 99/1 Classification Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ /3 $ MECHANICAL No. @ FEE WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. ❑I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. Date /`f% Signature o mitee r Agent �-, Receipt No. 7�7 White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant Land Development Fee $ TOTAL PERMIT FEE $ / SS This permit is hereby issued under the applicable provisions of the But County Code and/or resolutions to do work indicated abov Thich fees have been paid. �E OF P LIC WORKS r. 7 B Date Building permit expires Date v i CERTIFICATE C:c COMPLIANCE Issued to: i :i After Recording jeturn To: Paradise Pines Mobile:Home_.Estates, Inc. Public Works c/o McKernan & Lanum. P. 0. Box 550 Paradise, CA 95969 This Certificate of Comoliance.is hereby issued by the' County of Butte to certify that the land division which created the parcel of cronerty identified below complies with anolicable nrovi sions. of the Subdivision M`ao Act and of Chapter 20 of the Butts Countv Code. 1. Property location East of Skyway -Ehrlich Court 2. Assessor's Parcel Number: 64-66-21 Description: All that, certain oromerty located in the County of Butte, State of California, . more particularly described as follows: All that portion of Sections 23, 24, 25 and.26,.T23N, R3E, M.D.M.. described as follows: Commencing at the section corner common to Sections 23,.24, 25 and126 of.said township and range; thence N01°10'0011E 25.00 feet, thence S89°31'06"E, 60.00 feet to the true point of beginning; thencefrom said. true, point of beginning,.S89°31'06"E;. 40.92 feet; thence N01°10'00"E 30.00 feet; thence S89°31'06"E, 39.08.feet., thence S01°10'00"W, 226.03 feet; thence N89°31'06"W, 80.00 feet; thence N01°10'00"E, 196.03 feet to the true point of beginning. Excepting therefrom all rights of way and easements of. record. Issuance of this certific?ts is conditional. upon the follow— ing conditions which have been imposed pursua-+t to Butte. County Code Chapter 20-48 and Government Cod.--,.SAction 66499.35 (b.),. to.'protect the public health and public safety... 1. None c PERMIT NO. 3950-79P,E ' PERMIT EXPIRES OWNER Henry Loehr CONTR. Hess Backhoe, 2a§lx Paradise ' 64.-66-21 LOCATION (A.P. ) W/S Ehrlich Ct., app.300'S.of Skyway, Maga. h k: r( .I' y 4 J+fit f 1 • ,111', r { 1 �. Temp Power Pole Called PG&E Us Temp. Elea, Serv. 71, Called PG&E y /emmp. Gas Serv. Called PG&E JOB FINALED - f' (Date) C1J (Signature) COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS' R BUILDING INSPECTION RECORD BUILDING BUILDING (Cont'd) Shlback I FI wall So PLUMBING 1 3' 4�. .p.v r-orps If Para ets 1k Floor M n Bldg. Restro Finish 2n loor otin s Windows 3rd or St all Siding To out SIa Roof Sheath Water Pi i Pier Roofing Sewer Garage Fdn. Vents Fixtures Footingx Stemwal l Garage Vents Insulation Water Htr. Heaters Slab Carport Footings Prov. for physicall handica ed Conformance of ex. structure Appliances Gas Piping &Test Temp. as Slab y Final Sanitation Patio FIREP CE Final Footings Footing ELACTRIC4 Masonry Walls Throat Rough Reinf. Steel Final Fixtures Bond Beam FIRE SPRINKLE A Motors Mesh ' MECHANICAL Gird. F4 Prot. ScratA Heat Service/ B n Co ng TeA. Pole F Ish D is U der round Lath ntllation ermanent trior Closer Inal inal ILEHOME UT LIT ES ------------------ Elec_ Service Elec. Pedestal Water Piping --- Sewer Gas Piping M2§16EHOMEI S ALLATI N --------------Support Elec. Continuity p 4 4 Water Piping 3 GL Drainage 0Gas Piping 7 L` DATE REMARKS OR CORRECTIONS Aii� 1/V/C �V /'J 9 �= i 7 q (NOTE: An entry must be made on this form each time you visit the job site.) :t, P Yti � 1 . � �� Wv��`� • �� i e ��%�'W� r • ,. _ o � � , . _ e +�� D' � �� F � �. �. ti, � e � � .. ., ^ a � i � :, .. � .. ,R _ � 'a .. a .. i' - .� ',3•e.o� u � 'T � 9. Electrical A. Is service large enough to provide adequate..amperage•to mobilehome (must equal rating of- mobilehome with a minimum.of\l00-amp) and other facilities on lot, i.e., water pumps, garage, cabana, etc.? Yes No B. Is there proper clearances around panels? Yes Y No C. Is power supply cord or feeder assembly properly fused? No ' 'T No D. Is continuity test satisfactory as per the following procedure? Ye 1. De -energize electrical wiring system o,f the mobilehome at the edestal. 2. Make sure that the power supply cord or feeder assembly conductors, including neutral conductor, have been disconnected. 3. `Switch all breakers and switches in the mobilehome to the "on" position. 4. Connect one lead of a test instrument to the mobilehome grounding conductor and apply the other lead to each mobilehome supply conductor, including neutral. 5. All non-current, carrying metal parts of the mobilehome (aluminum siding, gas line, water line), including fixtures and appliances, shall be tested for continuity from such equipment and the grounding conductor. 6. Upon completion of the above procedure, the power supply cord or feeder assembly conductors shall be connected to the site service equipment. A further continuity test shall then be made between the grounding electrode and the chassis of the mobilehome. Upon satisfactory completion of the.electrical tests, the lot or site service equipment may be approved for energizing. ;10. Is job card signed by Health Department for water and sanitation? 11. If everything okay, sign off card and tag services. c i MOBILEHOME DATA Manufacturer and/or Namestyle �I,UL�LOC �-j�" Length GO Width :Z Vehicle Serial No. State Identification No. Additional Information or Comments: MOBILEHOME INSTALLATION INSPECTION CHECK LIST L. Is the mobilehome Located with required separation from lot lines and buildings and generally conform to plot plan? Yes No 2. Does the mobilehome have required clearances above ground? (Sec.5085) Ye No 3. Are footings and supports properly sized, spaced, and braced a �,t0 approved plans? (Note possible variation at spring shackles.) (Sec. 5082 & 5083) Yes 4. Is the mobilehome level? (Sec. 5088) Yes— o- 5. If o e than a single unit, are crossover connections properly installed? (Sec. 5088) Yes No 6. Water A. Isxible connector of adequate size and properly installed (1/2" ID min.)? (Sec. 5566) Yes No B. Test - Does wa r piping withstand working pressure or 50 lbs. air test? s No C. Backflow - oach is not State of California approved, does station have backflow device and pressure -r lief valve? Yes_ No 7. Wastes and Drains A. Is connection made with Schedule 40 DWV and have flex connectors at each end? Y No 'B. Does it have minimum k" per foot slope and is it properly supported? Yes /%�o C. Are any leaks detected in drainage system after running gallons of water through each fixture including washing machine standpipe? Yes_ No D. If coach is not State of California approved, does station have required trap and vent? Yes No 8Piping and Gas Vents AGa Connector - Is mobilehome connected to the gas supply with an approved 3/4" minimum mobilehome connector not more than 6 ft, long? Note: All piping is to be at least as large as the mobilehome gas line inlet without reductions other than the mobilehome connector. Yes No B. Test OK as per following procedure? Yes No 1. Open all appliance connector valves. 2. Shut off appliance burner and pilot valves. 3. Air test with manometer to 10"-14" water column, or test with slope gauge (minimum 6oz.-maximum 8 oz.) calibrated in tenth pound increments. Test for 10 min. without drop. 4. Connect gas meter to mobilehome with connector, turn on gas, test connections with soapy water. C. Are all appliance vents properly installed? Yes )'C' No qW COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of, the C l for ia�,*Administrative Code, Title 25, Chapter 5, under permit npmber L for the following location: t hJ[ ur H I rrl ', /1, .4 ,f Owner /,Lt Ili, Owner's Address S, �s� e Mobilehome WE. `�LyE t'- '.'!! l S r Model Year -41 Insignia No. s J }� S 3t Serial No. It is hereby certified for occupancy at the above described location and may be occupied. Director of Publ{ic Wworks Date f y Y B � THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED White- Owner, Yellow- Installer, Pink - D.P.W. t COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS / County Center Drive - Oroville, California 95965 Tel,ephone:'S344541., 5� J 2 �✓ APPLICATION AND PERMIT authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. is Date Signal re of Per mitee/or Agent Receipt No. 26060- White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the ButA County Code and/or resolutions to do work indicated abovi which fees ha a been paid. 4E F PU IC WORKS 11.4 1 Date -.- Building permit expires Date O v 04-36 BUILDING Owner SQ. FT. OCC. BUILDING VALUATION Mailing Address (� lep one�tJo (t/ (� d m�C1 /`f, /f'j� L i I / 4"'_1 Contractor X.i��V-�Fireplace Mailing Address Q f Total Valuation Q Q- 07o ' ,N Permit Fee Building Address L=�ie�lG�%,l Cl—�j� /� Planng Fee&/or Penalty Permit t Fee "� �A (�/iL�/Gj¢ �� O, W Q PLUMBING No. @ FEE PERMIT FILING FEE $3.00 Each Trap 1.50 Repair drainage or vent piping 1.50 A. P. No. 1p �p - p� �•� Zoling & L Planning Water piping 1.50 Each gas water heater or vent 1.50 F s FI re Dept. I FireZone Use Permit Gas piping system 1 -5 outlets 1.50 EQA Parking Plans Parcel Declaration Parcel Map 60' R/W Improvemen Each additional outlet .30 Building sewer 5.00 Bldg. Plans Recd Parcel roval Planpproval Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES ❑ OTHER Permit Fee $ $ 'l1i " ©� Q O �� 9 ELECTRICAL No. @ FEE PERMIT FILING FEE $3.00 Main service 600V OR LESS 100 AMP OR LESS 5.00 Single Family ❑ Duplex ❑ Mobil HomeV, Others ❑ Main service EA. ADD'L 100 AMP 2.50 Main service OVER sOOV 25.00 100 AMP OR LESS Main service EA. ADD'L 100 AMP 1.00 NEW OR ADDNST ( ACCLBLDGS,LING CCUP. 51 20sgft CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California Business & Professions Code under the name style of: NEW CONSTR BRANCH CIRCU NON.CRESID.ONST (BRANCH CIRCUITS 12.50ea NEW CONSTR. (POWER APPARATUS B NON.RESID. SINGLE OUTLET CIR. Ex. Occup{OUTLETS OR FIXTIIRES B L0; Ex. Occup. (OUT ETSP(RESID.)REA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 License No%- Classification Misc. Wiring 6.25 ❑ 1 am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE 1 am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. ❑I certify that in the performance of the work for which this permit is issued 1 shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No. @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 1 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby Is TOTAL PERMIT FEE $ authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. is Date Signal re of Per mitee/or Agent Receipt No. 26060- White-D.P.W. - Yellow -Assessor - Pink -Inspector - Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the ButA County Code and/or resolutions to do work indicated abovi which fees ha a been paid. 4E F PU IC WORKS 11.4 1 Date -.- Building permit expires Date O v 04-36 1. Owner's name: 2. Installer's na BUTTE COUNTY DEPARTMENT OF PUBLIC WORKS 7_County Center Drive, Oroville, CA. PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET 3. Is the site currently under permit? Yes No (If yes, furnish permit number ) OR h ` Is the site an existing site? Yes / / No (If yes, furnish two (2) plot plans.) 4.. Will the mobilehome be located at least 5 ft. away from septic tank and leach fields and clear of all setbacks and easements? Yes / No ( If no, clarify ) ( ) 5. What 'is the mobilehome electrical rating? ----------------------- ` Amps 6. What is the mobilehome site service rating? --------------------- Amps 7. What is the mobilehome site circuit breaker rating? --------=---- /S -i�) Amps 8. Is there any other electric load to be served by the mobilehome siteservice? --------------------------------------------------- Yes No (If yes, identify the load and size: (Load) (Amps) 9. What is the mobilehome site gas pipe size? ---------------------- \ (in.) 10. What is the type of gas service? -------=-=------------------- Natural LPG 11. What is the gas pipe length.from meter or tank to the mobilehome? (ft.) 12. :What is the mobilehome gas demand? ------------------------------ (BTU) (This information not required•if pipe length less,than 6 ft..on natural gals or less than 50 ft. on LPG.) MOB ILEHOME`SUPPORT DATA " If other than 'single wide, Mobilehome Mfr.iSo%L%'/lo, furnish Setup Model No. Year Width Box Length (ft.) Tagalong or Expando Size ft. x ft. (SHOW SUPPORT DETAILS BELOW) On all mobilehomes manufactured after October 7, 1973; furnish manufacturer's installation manual and structural setup sheets_(ifnot� on file with the County of Butte). All center supports measured -n® tftbnt of mobilehome unless otherwise specified. Footings (check one) Single 1. Wood either AApressure treated or foundation grade A. (ft.)(in:) (in.) (in.) 2. Other (specify) 09 Center support Center support locations* footing sizes (in.) (ft.)(in.) (in.) (in.) Supports (check one) 1: Concrete block. 2. Other (specify) <----Tagalong or Expando,' show support details. (ft.)(in.) (in.) (in.) p� x� -- Typical Support (in. (in.) Footing Size x (ft.)(in.) (in.) (in.)45 �,b -- Max. Pier Spacing (ft.,)(in.) Max. Overhang (ft.) (in.) (in.) (in.) (ft.)(in.) BUTTE COUNTY -AUILDING DEPARTMENT` APPROVE ; *If center piers are other than drawn above, draw in locations, spacing, and dimensions.^ COUNTY OF BUTTE — ',DEPARTMENT OF PUBLIC WORK V 7 County Center Drive — ...Orovllle, California 95965 Telephone: 534-4541 y� APPLICATION AND PERMIT�v autnorize repr sen at)ves or a county or t3utte to enter upon the above -mention d operty f ' nspe ti urposes. X DateJ� al— Signature of Permitee or Agent Receipt No. G a White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date %—/ 7— 7 4 Building permit expires Date 7—/ Z-,po BUILDIN Owner Akii 0,6 1 SQ. FT. OCC. BUILDING VALUATION Mailing Address Telephone No. Contractor Mailing Address o Fireplace Total Valuation Tele one No. Permit Fee Building Address Plan Checking Fee&/or Penalty Permit Fee � PLUMBING No. @ FEE "APAaP 38po 5 O PERMIT FILING FEE $3.00 3FOrD Each Trap 1.50 Repair drainage or vent piping 1.50 �i A. P.No. V 6 j �dnin ! Planning Water piping 1.50 Q,CD Each gas water heater or vent 1.50 Fps a i t>�Oi n Fire Dept. Fire Zone Use Permit Gas piping system 1 - 5 outlets 1.50 EQA Parking Park Plans Parcel Declaration Parcel Map 60' R/W Improvements Each additional outlet .30 Building sewer 5.00 Q, 00 B ldg. cans Rec'd r I A roval �-•` Plan ss Approval . Lawn sprinkler system 2.00 NEW ❑ ADDITION ❑ UTILITIES OTHER ❑ permit Fee $ D C ELECTRICAL No.1 @ I FEE PERMIT FILING FEE $3.00 �C7 Main service 600V OR LESS loo AMPORLESS 5.00 Single Family Duplex Mobil Home Others ❑ P ❑ ❑ Main service EA. ADD'100 AMP 2.50 v Main service OVER 600V 25.00 100 AMP OR LESS Main service EA. ADD•L 100 AMP 1.00 NEW CONST. ( DWELING OR ADDNS. ACCLBLOGS.CCUP. Y) 20sgft CONTRACTORS LICENSE LAW I am licensed under the provisions of Chapter 9, Div. 3, of the State of California usiness & Professions Code under the name style of: T NEW RESID,CONSTRANCH CIRCUITS NON-RESID BRANCH CIRCUITS 2.5Oea NEW CONSTR. fPOWER APPARATUS &11 NON-RESID. SINGLE OUTLET CIR, Ex. Occup{OUTLETS OR FIXTIiRES B LO; Ex. OCCU FIXED APPLNS. OR p•�OUTLETS (RESID•) EA) 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 5,00 License No. 5 0 65 Qq Classification Misc. Wiring 6.25 ❑ I am exempt from the Contractors License Laws of the State of California. Permit Fee $ $ WORKMEN'S COMPENSATION INSURANCE I am aware of the provisions of Section3700 of the California Labor Code which requires every employer to be insured against liability for Workmen's Compensation. J&I have placed on file with the County of Butte a certificate of Workmen's Compensation Insurance. I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become subject to the Workmen's Compensation Laws of California. MECHANICAL No @ FEE PERMIT FILING FEE $3.00 Heating Cooling Ventilation Hood 2.00 Permit Fee $ $ 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Lavtc relating to building construction, and hereby Land Development Fee $ TOTAL PERMIT FEE $ autnorize repr sen at)ves or a county or t3utte to enter upon the above -mention d operty f ' nspe ti urposes. X DateJ� al— Signature of Permitee or Agent Receipt No. G a White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant This permit is hereby issued under the applicable provisions of the Butte County Code and/or resolutions to do work indicated above for which fees have been paid. DIRECTOR OF PUBLIC WORKS BY Date %—/ 7— 7 4 Building permit expires Date 7—/ Z-,po <--� Z AV, /p/o /60'�l 9 7,3-50,V ELECTRICAL, MECHANICAL,AND RLUMBiNG . CONSTRUCTION ( NOT PLAN C. F - SHALL COMPLY WITH CURRENT OF NEG, Uy6C AND U s BUTrE otw r P. �® Sse the aftgc) 66 -5!F5QnW&an;-,str �ctat-An Pages