Loading...
HomeMy WebLinkAbout064-700-005cf-014 0 a r y d-v�ro r �� '� �� ���� RESIDENTIAL _-_�92_3g24-BPEM 11 _ 0-�-005 064- 7Lee HALSTRC colter Way + mnalia 14776 new Sf -- '4; a Y OFFICE COPY 1� - Address14'l2 _ COCT � iGAS Meter By Date �/ ELECTRIC Meter By a e Fg.�_. I� hOFFICE COPY n ` Address GAS t. Meter By a e ELECTRIC / 7 Meter By-1Date 2�t�G3 —_ J JOB FINALED (Date) — Signature A. V=OK O=Not OK Not_=Noi �yable MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s ' 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/O Concrete 1 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Gas; Location -Test -Wrap: / /-L-ft. / /"Nat. or/ /"L"ft./ /"LPG - - 7. Well Clearance & Disconnect 8. Utility Clearance N_ Date Card B-1 Date Card'B>1 Date Card B-1 Date Card'B-1 .Date MOBILE HOME INSTALLATION (Plans) OK except #'s 1. Zoning Requirements -Setbacks Easements 2. Footings; Size -Spacing -Marriage Line 3. Gas; MH Test -Demand -Valve -Connector 4. Electricity; MH Test -Crossovers -Breakers -Clearances 5. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector 7. Water and Sewer Connected -C/O to Grade -HD Approval 8. Gas and Electricity Tagged 9. Exits; Insp.-Sketch 10. Cert. of Occupancy Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts -Bea ms- Rftrs.-Connectors Shthg.-Rfg.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements \ 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining '+ 4. Elec.; Receptacles and Lighting, Distances-GFI ` a 5. Elec.; Pool Lighting; 15 volts-GFI �. 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed --- 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater -- 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. _ Boxes-Enclosures-Panelboards=Iris. to Main in Conduit 9. Health Department Approval -a 10. Plumb.; Cir. Test -Water Suoolv Test __j Date Card B-1 Date Card'B-1 Date Card B-1 Date Card B-1 I .% _, t t»N t ti J J=OK O = Not OK = Not Applicable RESIDENTIAL.(: = Not Ready Date UND LOOR (Plans) OK except ft's Zo g -Setbacks -Easements -Flood -Slope . Ftg.; ain; Soils-Elec. Grnd.-/ /" Ftg. Depth (J U 3 g., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth g., Porches & Decks; Soils -Steel-/ /Ftg. Depth 5. Stemwalls, Main; Steel -Bloc kouts-Wra pped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Flald Downs and Special Anchors J Slab; Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test f 11. Water Pipe; Test -Anchor -Regulator -Service Test 12. Electric; Underground 13. Pienums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples 15. Access & Ventilation 16. Insulation Date 1z. -IT-el 2 -Card B-1 &rDate - Card B-1 Date �''Z�/ a�6-1 Date Card B-1 Date PLUM (Permit),OK except n's Vent -Access -Combustion Air -Baffle '�_Wateer Pipe: Test & Anchor -Nail Protection p�u`.w.V.: Test -Fittings & Anchor -Nail Protection --------TT-Shower P est. First Floor -Tub Access L17_7 - ub & Shower, Second Floor -Tub Access --------- ---- ------------------ ---- Gas_Pipe_ ize Anch rs -------- - ----- --- - --------------- Date and B-1 Date - Card 6-1 — - ----- ---------t --------------------------------- - Date Card B-1 Date Card B-1 Date ELECTRICAL_4P reit) OK exceot ft's & Transformer Clearance - Ins. -Protection --------------------------------------------- -- e5ep les Spacing -Lights & Switches at Doors xes & No. of Conductors -Stapled ---------------------------------- ------------- -----------------_-_-------- ex Installed Close to Edge of Studs & C. ------------------------------------------------- -- quip Ground made up w/Meth. Fastner -Bon as & Wat ppliance Circuts in Kitchen & Conductor -6ubfe ire Sizer r ga Cu or AI-A.C. Wire Size r� ga. _ _Cu o AI Range Circ. ! ga Cu or AI -Oven Circ. / ! ga. Cu or Al. In ated Neutral ❑ Yes ❑ No Ser -Riser Conductors & Ground -Main Disconnect - - E uip. Clear- s Panel s-Motors_Mech_ Equip - - - -- ------ ----- - Clot - -loser Light Shower Light Spa Light -------- ------------ - - moke Detector -------------------------------- -- --- ------------------------------------- --atej----j_-- - - ------------------ ------- D ------- - �- -------1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECH !_ (Permit) OK except n's 3 A.C. Ducts Insulation & Support ------------- ------------------------------------------------------------------- -9b -Vent Fan: Exhaust above insulation ----------------------------------------------------------- --- -----.._.. - •-3��ondensate Drain & Overflow: Size & Grade rna-- -Vent: Access -Comb. Air -Return Air Vent -115 outlet --- ---------- -------------- -- ---------------- Attic ------ ---- Attic Access & Platform if Furnance in Attic ----- -- ------------------ ------------------ ----------- - Date �- Card B-1kDate Date Card -B-1 --- - --- --- - --B- - ------------ -------- Date Card B-1 Card B-1 Date FRA (Plans) OK except 4's 31f_Sj1,, roper Material & Anchors suds Nailing. Spacing & Bracing -Plates -Sound - llls over Girders -&-Floor Nailing Dr pin Walls (rat proof) -------------- ---. . Wal- - (r ---roof)__---------- ------------------ Le S Furred Ceilings -Stairs -Chases -Tub- -- -------------- ---------------------------- -- ----------- eaders & Beam -Size & Bearing ')h1gle & Duplex) Date RAMING (Continued) _ _ _gers-Post Caps -Anchors -Connectors Joist-Rftr. ties -Pu rlin-roof Brac-T -Shthng.-Ring. --- 4 . Fir ce Ties or Type A Flue -Fireplace Throat clearance tt' Access; Size & Romex Protection -Draft Stop -Ins. Baffles or Exiting Doors -Sill Hgt. & Dimensions _ Garag_e Fire Protection Framing --------_�sr-Pr y Line Firewall & Openings E_ ors -One 3' -Check Garage -3rd Story, 2 Exits _ Stair .-- -Headroom-Rise-Run-Landing-Fire Protection -- -- --- —od on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing Veneer ------------- 5t. Stucco Mesh -Drip Screed -Fd. Vents�Underflr. Access --------- --_- --_ a_zin ass Protection -Skylights Plastic boa Walls: Nailing -Bolts ` _ In tion -Walls -Ceilings L�-F4 �`1�-- - - Infiltration -Walls -Windows DatW- Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL s) OK except 's xt. Steps -Door & Sidelight Protection -Landings -- --- --- e Detector 1___.rn9 urnace: Vents -Clearance -Comb. Air -Connector - n Garage: Above Floor -Ducts -Meth. Protection l._-- -------------- ---------- -- . 6 ,& Bath Fixtures & Tub Access -Spa let im & Subpanel: Breaker Sizes & Labels Stairs & Rails 68. Fireplace or Stove: Clearances -Hearth --- ­49-Elec. Outlets at Wood Panel: Int. & Ext. ------ -- it.Fixt & Appli-ance:�Grnd.-Ai dooking Clearance ec. Outlets & Receptacles at Kit. Counter ---------------------------------------- arage Fire _Door: SARglCanding-Closer - --.42r+A.C. Du in Garage -Damper 7Vents-Clearance-Comb. Air-Connector-P.R.V. In Garage: Above Floor -Meth. Protection ec. & Mech._Equip. Listed for Location - 76. ec Receptacles in Garage: (G.F.I.)-Romex Protection tion -Foam -Looked in Attic __10' eess- 78. u Rails & Deck Construct' n -Post Caps ------------------------- -- dn. Vents &Crawl Hole Door -Drainage ood-Earth Clearance Looked under Floor— - ❑ Yes -.a0-Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No --- — - --isl.Stucc Brown -Finish - - C. Unit: Disconnect. Electrical, Plumbing 83. Vents Above Roof: Plbg.-Appliance-Fireplace.-Clearance to Openings X24 -Water ell: Disconnect, Electrical, Plumbing i�erior Elec. Trim; G.F.I. Receptacle -Underground - --------- n ' on Throughout House Ia5e1rotection o coons from Previous Inspections /__1b -4X ` Gas Test -Meters Taooed Gas -Electric --- -- - -- - -- - ------------ Water & Sewer Connected -C/O to Grade -HD Approval 91. Energy Compliance Certificate -Other Certificates Date �b -----Card B-1 ----------- Date---- Card B-1- --- --� - -- -- --- ------------------------ Date ______ Card B_1 -------------- Date -- Card B-1 Date Card B-1 Date Card B-1 Comments at Final COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 . 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 • CORRECTION NOTICE .8 L S rCZ0C'L'- 2 - Z ovmm PERM NO. A toutrre inspection indicates that the following violations of Butte County Ordinanc s exist at the above address and should be corrected. Please notify this office when correction of work its corn pleted. If you have any questions pertaining to this matter, or need addRion56to."planation, please contact this office immediately. . VIE" -Iur= COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 CORRECTION NOTICE O17 HEIR PERMIT NO. r Z►uoufine inspection indicates that the following violations of Butte County Ordinances exist at 7tbe above address and should be corrected. Please notify this office when correction of work us,conipleled-If-you have any questions pertaining to this matter, or need additional explanation, ` please pct-3his office immediately. sett � '/e/ 2r2 A n I COUNTY OF BUTTE s DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 Co,9t�,,Cent%%r,Driye, Orovi Ile — Phone: 538-7541' E;Iliott 747,rLad; Paradise— Phone: 872-6307 CCRRECTI-ON NOTICE 4,0t 5Tgv� OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be' corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. ��i/�'/I/f� sly i/!?s /Z (• R7 �2 Sd�.�elit✓ _ It `I ( 4tc (-) Z o IV .y Date 17Inspector OWNER-:�r�-S.– /7���i�Jnl PEF:1-11'1' • _ ��_�_-��� • ENERGY CERTIFICATION DESCRIPTION OF,, INSULATION ROOF MATER I Al_ THICKNESS - _- EXTERIOR WALL MATERIAL Fiberglass TH I C KNESS ' 1 j FF:ANU hJAME: CertainTeed THERMAL --- BRAND NAME CertainTeed THEFMAI . RES. 1 S CEILING HATT- OR L(LANKET'' TYF�c.. Fiberglass Mt= CerthinTeed TH)'C:1=.NE5S � _ + _ F4E I<'MAL. r-, ES L004.4:. FILL nsulsaf e III BRAND NAME CertainTeed TI41(::h:NESS -THERMAL RES. 3!T FLOOR -ELEVATED MATERIAt- Fiber lass BRAND NAMT: CertainTeed THICKNESS ' THERMAL RES. %— FLOOR -SLAB I NT ER I OR' WALL MATERIAL Fiberglass BRAND NAME CertainTeed THICKNESS THERMAL FEES. - h HEREBY CERTIFY THAT THE ABOVE INSULATION WAS INSTALLED IN THE ASOVE BUILDING IN CONFORMANCE WITH 'T'HE STATE OF CALIF. ENERGY P.EQUIFtEMENTS'. HAWKINS ND. I /dba SHASTA INSULATION LIC. #650722 S / / Y-3. SIGNATURE. DATE; I HEREBY r EPT I F -Y THE: ABOVE INSULATION AND ALL REQUIRED 1TEM� 'AS SHOWN ON THE: SUILDINu DEPARTMENT Ar-F''ROVED FLANS AND ATTACHMENTS RAVE BEEN' TNSTALLED AS PEOUIPEI) BY THE a STATE or CALIFORNIA ENERGY RECU I FE ME NT S . ALL EQUIPMENT, DEV I C:ES O' AND MATERIALS ARE OF DUALITY PkESCR I BED OR ARE SF'I: C:1 F I CALLY APPROVED. FAY THE STATE. SIGNA URE OF NERAL CONT/OWNER STATE CONT.LICO 'Thies certificate must be on file with thN Puildinn Dept. -prior to Final and P-.-S:ted within building. COUNTY0. BUTTE - DEPARTMENT OF PUBLIC 7 County Cente rive SOroville, Californii 95965 - Telephone: APPLICATION AND PERMIT WORKS '�151> PERMIT NO. 916/538-7541 I VQ PERMIT 3 9 ASSESSOR PARCEL NUMBER 064-700-005 ZONING 'RT_ BUILDING PERMIT OWNER Lee Halstrom TELEPHONE 873-2794 SO.pFT. OCC. BUILDING VALUATION 1,378 R 74 412.00 OWNER'S MAILING ADDRESS Magalia1,014 M 18 252.00 CONTRACTOR'S NAME Ownpr TELEPHONE 472 COV. 6,136.00 CONTRACTOR'S MAILING ADDRESS None 300 Open 2,10-0-00 Fireplace CONSTRUCTION LENDER UNKNOWN Total Valuation 1 $ 102 400.00 LENDER'S MAILING ADDRESS Filing Fee $ 15,00 Permit Fee $608.06 - ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ 304.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Energy Plan Checking Fee $ 20.00 Penalty $ BUILDING ADDRESS Permit fee $947.00 PLUMBING PERMIT Filing Fee 15.00 14776 Colter Way. Magalia Each Trap 101 5.001 50.00 Solar or heat pump water heater 20.00 LOT NO. 112 SUBDIVISION NAME P P #2 PARCEL MAP 35-72 Water piping 11 7.001 7.00- Each qas water heater or vent 1 7.00 7.00 USE OF STRUCTURE SF ® Duplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 1 5.00 5.00 Building sewer 15.00 15.00 Mobile Home S I G I W @ 15.00 TYPE OF WORK New [3 Addition ❑ Remodel ❑ Uti lities ❑ Installation ❑ Other ❑ Describe work: New 3 Bedroom Single Family Permit Fee $ .00 Contractor ELECTRICAL PERMIT Filing Fee 15.00 Main service 200A OR LESS 1 1 18.501 18.50 Main service 200A TO 1000A) 37.50 CONTRACTORS LICENSE LAW I declar nder penalty of perjury (check one): 1 am licensed under provisions of Chapt. 9, Div. 3 of the BuslnesS and Professions Code and my license is in full force and effect. License No. Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST./ DWELLING Occu2" 3.64sq.ft. OR ADDNS, ACC. BLDGS. ( 83.70 NEW CONSTR ULTI.OUTLET NON, BRANCH CIRC ITS @ 5.00 POWER APPARATUS trL__ (SINGLE OUTLET CIR. ) Ex. Occup(OUTLETS OR FIXTURES 20 76d Ex. Occup. OUTLETS PI RESID IREA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring '15.00 Permit Fee $ 117.20 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ❑ I have placed on file with the County of Butte Building Department a ertificate of Workmen's Compensation Insurance or a Certificate Consent to Self -Insure. 1 shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Contractor MECHANICAL PERMIT Filing Fee 1 15.00 Heating 1 k1.00111.00 Dual Pak Cooling g 16.00 Hood 1 6.501 6.50 Ventilation Permit Fee $ 48.50 Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, ag d expenses which may in any way accrue against sa'd Cou t of,the granting of this permit. X �� Date Signature of Applicant - Owner Contractor ❑ Agent ❑ An OSHAwork permit is required for excavations over 5'0" deep and demoli 'on c nstruct- ion of structures over 3 stories in height. Mobile Home Installation Fee S Energy Inspection Fee $ 40-00 occ -1,251.70 CONST TYPE TOTAL FEE HAz DFE IMP FLOOp V CDF PARCE}t Po HD 1- IssuE lo This permit is hereby issued under the applicable sions of the Butte County Code and/or resolutions indicated above for which fees have been By ) E R OF PUBLIC WORKS PER 1 E PjR S Date Date provi- to do paid. _ Receipt No. " %I �' s� 2Z�i o Jr v 7® WHITE-D.P.W.. YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENR D -APPLICANT / COUNTY OF UTTE - DE � 7 County Center ve - Ofoville, APPLICA 'PARCEL NUMBER I iiR. R —0 toWNSSS � IL y,G ADDREI__: W TMENT OF PUBLIC wutl^J Irnia 95965 - Telephone: 916.'536-7541 ANC- PERMIT BUILDING PERMIT �SQ. FT, OCC. BUILDING VALUATION iIN '7G� .nzz Z �ONTR .CT R'S NAAM`E ^ S �I L� C 0147ACTOR'S MAILING A ��EJSS //, ` N Tj�I� f S /G/�U UNKNOWN Fireplace J Total Valuation $ / Filing Fee 15.00 CONSTRUCTION LENDER Filing Fee LEN ER's MAIL ADDRESS �e LICENSE No. Permit Fee O` Plan Checking Fee .-f - L� ARCHITECT OR ENGINEER Energy Plan Checking Fee 12 ARCHITECT OR ENGINEER'S MAILING ADDRESSPenalty 6.50 AF-> ' J —.. Permit fee BUILDING ADDRESS S PLUMBING PER Ute— ( Each Trap Solar or heat pump water heater Contractor PARCEL MAP Water piping LOT NO. SUBDIVISION NAME 1-17;3 L_�J -7 ch aas water heater of vent ./ $ Gas piping system 1 - 5 outlets USE OF STRUCTURE _ Building sewer Duplex ❑ Mobi lehome ❑ Other SPECIFY Mobile Home S G W SF TYPE OF WORK _ Fee New V,?� Addition Describe work' _ CONTRACTORS LICENSE LAW Permit Contractor ELECTRICAL PERMIT Main service 200A OR LESS Main service 200ATO1000AI NEW CONST. DWELLING OCCUp'&) OR ADDNS. AGC. BLDGS. cr I declare under penalty of perjury (check one): �siness am licensed under provisions of Chaptlicense is9inDlfulv. 3forceof handueftect and Professions ode and Classification License No. I, as the owner, or my employees .with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) F] I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) Business and Professions Code (] I am exempt under Sec. for this reason WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): C] The permit is for $100.00 (valuation) or less. 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate o Consent a ploySelfany person in any manner so as to become subject shall not employ y P to the W. C. laws of California. Notice to Applicant: If after making this state must shohwiuld lh comply wiou become th such to the W. C. provisions of the Labor Code, you 19'0' ins or this permit shall be deemed revoked. ove rmation ct. I a9 ee tohave rcomplyead sto application Ordinances and State Lawsrelating to ole enter uponcthenabove-menand to edhpropertyorize f or nspection pu po es.tatives Of the of agree to save, indemnify and keep harmless the Counin f Butte agai st Ibilities, judgments, costs, and e(� ensesiwhich of tmapermity y t said untv�9 j/ �' � /' Date lJ �/ Controctor Agent 0 re of Applicant - Ownerl� A permit is required for excovations over 5' deep and demolition or construct structures over 3 stories in height. � I N,-_'_ -v - SINGLE OUTLETICIR ) X. Occup OUTLETS OR FIXTURES FI%ED APPLNS. OR E OCCOUTLETS IRESIO.I EA. Home Facilities Misc. Wiring V F 11 i ngyee 18.50 7.50 3.63 aq•I t. I @ 5.00 3.00 15.00 15.Oc 15.Oc 15.00 C— i 15.00 Permit Fee S Contractor MECHANICAL PERMIT Filing Fee 15.00 Heating Cooling 6.50 AF-> ' J Hood Ventilation �— S Permlt Fee Contractor Mobile Home Installation Fee S Energy Inspection Fee $ 'J DCC CONST TYPE TOTAL _ This permit is hereby issued under the applicable provi sions of the Butte County Code and/or resolutions to do work indicated above for which fees have paid. DIRECTOR OF PUBLIC WORKS By Date PERMIT EXPIRES Date ------- a1 COUNTY OF UTTE -DEPARTMENT OF PUBLIC WORKS PERMIT NO. 7 County Center (t11„ve - Oi�wille, California 95965 -Telephone: 916,'538-7541 Z� ,9 APPLICATION• AND PERMIT ASSESSOR PARCEL NUMBER y_ _ ZONING 1__ BUILDING PERMIT OWN RTELEPHONE 71 -1 -0A 1 -W73 -.2-71'f SO. FT. OCC. BUILDING VALUATION , > 'y �- OWN 'S�+IAI LI G ADOR E55�� �� �• (�-J �t .i Q CONTR CT R'S NAME s TELEP ONE 'Z ` �i.V to 3 42 CO T ACTOR'S MA/}I ING A E55 / �d Fireplace ,( ) 00 CONSTRUCTION LENDER UNKNOWN Total Valuation $ Filing Fee $ 15.00 LEN ER'S MAIL ADDRESS �� X � Permit Fee ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee a”? Energy Plan Checking Fee $ 210: ARCHITECT OR ENGINEER'S MAILING ADDRESS �.. Penalty $ BUILDING ADDRESS Permit fee $ J95�2' PLUMBING PERMIT Filing Fee 15.00 1) /4f % 7,e/ o (tC'�L � Each Trap ® 5.00 S - Solar or heat pump water heater 20.00 LOT NO. SUBDIVISION NAME % `--+ PARCEL MAP �• 31 1 -% Water piping 7.00 ch qas water heater or vent 7.00 7 ,�� USE OF STRUCTURE SF Duplex❑ Mobilehome❑ Other L� SPECIFY Gas piping system 1 - 5 outlets 5.00 Building sewer 15.00 Mobile Home S I G I W @ 15.00 TYPE OF WORK New Addition ❑ Remodeel ❑. U,ttiiliittiees o Installation❑ Other ❑ Describe work: Permit Fee $ Contractor ELECTRICAL PERMIT Filin a 15.00 Main service 600VORLESS 200A OR LESS 1$ 50 d S Main service 20CATO 1000A1 7.50 CONTRACTORS LICENSE LAW 1 declare under penalty of perjury (check one): �am licensed under provisions of Chapt. 9, Div. 3 of the Business and Profession ode and license is in full force and effect. License No. Classification //7 ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. ( DWELLING OCC OR ADDNS. ACC. BLDGS. 3.60 sq.lt. NEW CONSTR. ULTI-OUT LE NON•R ESID BRANCH C'. Cu ITS @ 5.001 POWER APPARATUS S (SINGLE OUTLET CIR. Ex. Occup(OUTLETS OR FIXTURES 20 76 AL 0 461 Ex. Occup. OUTLETS ED APP(RESID.ILNSREA.) I 3.00 Temporary service 15.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ -11-150-1 Contractor p WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. F-1 1 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. [jk-'lf shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 1 15.00 Heating rj�9 4 PSG Cooling Hood 6.50 ,6 !f3 Ventilation Permit Fee $ , Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against sai ty ' e granting of this permit. X e� _Date �— ! Signature PP E Contractor g An OSHA permit is required (or excavations over 5' deep and demolition or construct- ion of structures over 3 stories in height. 09 A Mobile Home Installation Fee $ Ener y Inspection Fee $ �J CONST YPE TOTAL FE MAz DFEES IMP I FLODD CDF I PARCEL 4 PD D ISSUE This permit is hereby issued under the sions of the Butte County Code and/or work indicated above for which fees DIRECTOR OF PUBLIC By EXPIRES Date applicable provi- resolutions to do have been paid. WORKS Date Receipt No._. �•� rzewPERMIT WNITC-D.P.W.. T<LLVv,-n;id�;i:v .. .._ _I nrNPOD-APPLICANT �'iik+tti�#Y*rl`¢'-.Yr''.• ��..:..w • '�' 4'cr.+'�Vy and t., ,. .... - t 4-Z; CQUNTY OF BUTTE, PA�2TMENT OF F.UBLIC WO BUILDING DIVISION .. ,, . r. ; 7 COUNTY CENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER I Let 14141ST Proposed Building Use 3,Irti - Building Inspector_ A. P. No. / ?o 0 6-- Date it b'.- At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED By 1. All items have been submitted . ........................................ 2. Plot plans, 3/4 sets, signed by preparer of plans . .......................... 3. Complete plans, 3/4 sets, signed by preparer of plans . ..................... . 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form . ............................................ 6. Energy Design Compliance and supporting documentation . ................. . tatement of Intent for Non -Heated and A/C Buildings . ...................... 8 Engineered truss details and layout in duplicate (required prior to plan check). .... Mobilehome data d m df cturer's installation instructions, 2 sets. ........... Fees of $......................................... 1112;;AS' - _ /Zd 11. Impact fees as shown on attached schedule . .............................. 1 1 'California Department of Forestry plan approval/fees. ....................... . 3. Flood elevation letter (100 year flood) by California Engineer. ............ . 14. Sanitation and plot plan approval ^ Health Department . .............. 15. City of Chico plumbing permit. ........................................ . 16. Plot plan and business license approval from City of Biggs/Gridley. ............. 17. Planning approval for (A) Use: (B) Parking: . ....... . r(k8. Contact Land Development about (A) Improvements (B) Drainage. ......... . 19. Driveway permit (construction approval required prior to occupancy). . tsrequest' 20. Pre -inspection for required. to Building Inspector reale 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... Owner -Builder Verification (Given to owner , Mail to owner'_) ........... . 24. Recorded copy of Agricultural Acknowledgement Statement . .................. 11- �� r92 Kfs 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . .......................................... 28. Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ........................................ 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... 32. Plan check list . ................................................. . 33. 1Z 34. When you issue the permit, process as follows: ✓Mail to owner. Mail to contractor. Telephone and hold for pickup at office. Deliver with inspector. Other �--- Parcel Creation ell Acreage Applicant Date LL Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to permit issuance: Ire w iteMch c above). 1. Index permit for above items No. 7N, 2. Additional items required: Contractor, designer, owner, was advised of above required data by _ phone -mail Counter by _ Date Contractor, designer, owner, was advised of above required data by _ phone _ mail Counter by _ Date Plans checked by Date Plans approved by �� Date �f�9v Sets of plans on hold in File cabinet AP folder Copy - Department of Public Works TO:. Building Department FROM:` Encroachment Permit Section RE: Driveway Clearance Zee- 41A 6 422� owner G. 7.7 6" Co Ile,,- "S/ . location Driveway permit q7 -l-11 12-- l= '16 s i ature (o�--7D-off AP # has been issued for the above property. 8 date ' �, 1;IlIINI'Y 111 IIIII-II: --- lil'.I'AICIIIIIII' Ill• ('11111.11; N(IIIR`; --- IIIIII.I11111; IIIVI';Illrl I CO I'Y I;IJI'I'1':It I)I(IVI llltllv11.11., l;Al,ll(IIIIIIA y';�)(i'� II'.I.I':I'lllllll'. ('Illi) roll l`i��l ul�rn.0 IIA 11I10l os El) Illi l 1,111 N(, USE REI;. � UAI'E ITEC -i I, School Illat:rlctFees (pold "tIIIst:111;1: Off)c) .......................... 1, Sher I f f. Fees (pold at Ilulldlleg Ueportmeul:) Ilealde11tlal — till Coumerc 10 I ( per R-- _—��- sq . f t. "lilt. 3. Ih bme Area Fees_ -- (paid et Building IlepOrtmeut Iteslde11tlnl (per milt)_ _ V -111149 _ --_x _� 1111 l t s 8111t. Conunel-lcal(lier-- s�1. nlnt . t1. Itecientloll Iltatrlct: Feea —_ (I►ald at I)lstrlct Office) .......................... 5, Ilrnllinge Of 91:1 -let Fees (Co11tact (still hevelopnlenl:) ......................... 6. Other 7, Other At time of permit "I'll"cat:loll, I was advised the above fees ere reg11lred to Ile 110141 prlor to 1 ssumice of the I►ern11 t . DATE AI'I'I.ICOT AK4 t �,x,3,.�r,,K;,y;,�,,,o _ �'*�°+""^�:^%r++�'tr4gr'�?�+r��+a+�+.,rt�yr^"�,,,,.^,.,�r--�...rw�."�'aiwM+�i*'rk:�»,c'r'c�;�*t�4-.n=?`"9"p"�zar�rc�«•r..a., BUTTE COUNTY SCHOOLS, IMPACT FEE CERTIFICATION FORM ry O .tp, (One Form Per Building) COBN�p1NGo�p 2 4 School District a Building Department No. A.P. Number /Jurisdiction 0 City ®�ounty Property Owner Property Location/Address Subdivison Lot No. Residential Development [ 0 = Sq. Footage �v No. of Living MHI Addition (Group R) Units Commercial/Industrial 0 Sq. Footage New Addition (Including Exterior Roofed Areas) Building Department Representative Date (Floor Plans reviewed by School District Personnel) lentification No. QGL�[.d.Q.cQ School District certifies that �Co (Applicant) (Street Address) complied with the requirements of Resolution No. esenting 0 square feet. of District Representative e�72 79 (Phone Number) . (State) (Zip Code) U by payment of $ Paid by Check Number Remarks. Bank Number Paid by Cash Date If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully miti-gate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeformmkt (4/92) Return to DPW _AGRICULTURAL STATE W (( " ACKNOWLEDGE` NT FOR RESIDENTIAL -DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. 92=54368 The property described herein is adjacent 1 Fee 5. 00 to land or included within an area zoned 92-0543681 Rec I Cash 5.00 for agricultural purposes, and residents of this property may be subject to incon- Recorded I veniences or discomfort arising from the use of - agricultural chemicals, including, County of I but not limited to herbicides, ,pesticides, ButteI and fertilizers.; and from the pursuit Candace J. Grubbs I of agricultural operations including, Recorder I PUBL XX 1 but not limited to cultivation, plowing, 2:55pm 25 -Nov -92 I spraying, pruning, and harvesting which - occasionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property' should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. -'All that r_eal.property. situate in the County of Butte, State of California, described as follows: _ Lot 112, as shown on -that certain Map entitled, "Paradise Pines Unit No. •2", --which•-Map was -recorded in -the -off ice of the Recorder of -the County- of Butte -,:State, of -California, on June 10, 1970,' in " Book 35 of Maps, at Page(s) 71, 72, 73, and 74. I xcepting therefrom all of - the -valuable - minerals, and--al'1 oil, gas, asphaltum' -and other" hydrocarbon --substances -beneatli the .surface- of -.� ` i the said lands -with the right -to mine and extract said minerals and I all- oil, -,gas, -asphaltum and other hydrocarbon substances,--it-being I agreed -and -understood that--in-all--of.-these-,operations, the surface of -said -lands -will be protected against damage and -that -all operations--rel-a-ted thereto- shall- be carried, on from. -tunnels, -shafts Lor drifts having their orifices outside of the surface area of the above I described property. _- Date: November 25 1992 PROPERTY OWNERS: State of California) On this the 25th day of November , 19__U , before me, the ) SS. undersigned Notary Public, personally appeared County of Butte' ) _' Fry OFFICIAL SEAL Personally known to me. © Proved to me on the basis `�Q- 'UFEk '•••gym BARBARA A. WOODWARD of satisfactory evidence. ® be the person(s) NOTARY PUBLIC - CALIFORNIACALIFORNUI p whose name(s), was BUTTE COUNTY subscribed to the within instrument and acknowledged that he '9 IFO" My Comm. Expires Sept. 24, 1993 executed the same for the purposes therein contained. IN WITNESS WHEREOF, I hereunto set my hand and official seal. Present A.P. No. 064-680-024 • Notary Public ,� Eta) ®IF DOCUMENT RESIDENTIAL PLAN CHECKING GUIDE 8/91 (-S.F., DUPLEX.& MISC. ONLY) Bldg. Permit # -2' 3 l� OWNER �L�� \ /Y� A.P. # Plan Ch c r4- k S GENERAL oning requirements: (sideyards and number of permitted living units). Valuation. ;°!/Plans signed by designer. . Proper description of work on application. ( Existing violations on property. .ems on data sheet. (W.C., fees, Health, Developer Fees, License law, etc). Recorded notice of violation. PLOT PLAN Complete parcel size and dimensions. tbacks, sideyards, easements, etc. Other.buildings or structures. Grading, fills, drainage. Flood.hazard. Special conditions on creation map, ustible, and foundations). FAU & FAS road setback. (noise, CDF, fire sprinklers, non -comb - Building or utilities across lot lines (Record form). FLOOR PLAN %Complete to scale plan with dimensions. �equired windows for light and ventilation (Sec. 1205). eauired windows for second exit (Sec. 1204). �kylights (Chapter 34 & Sec. 5207). . Aman impact glass (Sec. 5406). /Required room sizes, ceiling heights (Sec. 1207). �FCIs in baths, garage, kitchen, and exterior outlets (Article 210-8). /6ht fixtures, switches, receptacles, and exterior receptacles for main- ance of mechanical equipment. ocations of water heater, heating and cooling equipment, other electrical as equipment. arage firewall, door size, and closer (Sec. 503(d)(3)). �- 3'0" exterior exit door (sec. 3304 (f). ,��F. eplace and wood stove location, alcoves, and clearance. 3!�oke detectors (Sec. 1210). . Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS Standard bracing or engineered design (Table 25V) Unusual shape, size, or split level house requiring lateral design. r --Clerestory requiring balloon framing and/or engineering. �hree story building requiring -engineered calculations and plans. . Foundation plan complete enough to construct building. / Floor construction details complete enough to construct building. levations and wall construction details complete enough to construct ,i Roof construction details complete enough to construct building. Fireplace construction details and calcs if necessary. Rafter ties or bearing ridge beam. ?.'—Garage door or porch header sizes. I-'*'S-tud heights. 3-�4dobe soils - special foundation design. '+' Retaining walls requiring design. Special Inspection required. building 8/91 RESIDENTIAL PLAN CHECKING GUIDE MISCELLANEOUS ITEMS TO LOOK OUT FOR Stairway details: landings, rise and run, head clearance, handrails -Sec. 3306). uardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). xterior plaster - weep screeds (Sec. 4706). roper roof pitch for roof convering (Chapter 32). Roof covering type - (fire hazard). i� am insulation - protection. =' halls and stairways. Living area over garage - complete 1 -hour separation required on garage side ncluding supporting walls and posts, etc. o exits on three-story dwellings (sec. 3303 & see Mezannines - 1716). is access and ventilation (Sec. 3205). nderfloor access and ventilation (Sec. 2516). • Combustion air for fuel burning appliances - L.P.G. requirements. • Oise requirements on duplexes. ['SSE ergy design. - hing at all exterior openings. OF responsible area requirements. 9X 3 A qxp �� 1 in S T R U C T U R A L CALCULATIONS F 0 R TYPICAL RESIDENTIAL FOUNDATIONS HALSTROM i:ONSTRUCTION P.O. BOX 545 MAGAL I A 9 CA 95954 CALCULATIONS ARE IN COMPLIANCE WITH THE 1991 EDITION OF THE UBC SIGNED _ _ _ _ _ _ DATE --FF'ANF:—L_ a TYUk:OS RCE 04.4-- -- — --- cp�. �� F� ENS ' I, 4I Nim 90 1 k OAD PARA I . CA 95969 C9i" X372-0254 SUBJECT: TYPICAL RESIDENTIAL FOUNDATIONS BY: FLT DATE: 10/92 JOB NO.: 2171 PROJECT: HALSTROM CONSTRUCTION P.O. BOX 545, MAGALIA, CA 95954 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA SHEET 1 OF 6 DESIi�N i=:f=:iT'E�:IA: STUD WALL, WALL., FLOOR & ROOF ARE SUPPORTED BY i_ ONS RETAINING—BEARING WALL FOUNDATIONS. CONCRETE WALLS ARE SUPPORTED @ TOP BY CONCRETE SLAB AND AT THE BOTTOM BY CONTINUOUS FOOTINim. CODE 1991 UBC SUPERIMPOSED LOADS MIN. DL_ = .010 x (3+8) = .11 k:/1 MAX. LL = .030 x 17 + .010 x (17-3) + .050 x 5 = .90 k / 1 LOADING PER ABOVE IS CRITICAL FOR BOTH — BEARING (INCLUDES DL+LL ) AND SLIDING RESISTANi=E(MIN. DL ONLY), MAX. LL — ROOF SNOW + ADD'L LIGHT ROOF DL + FLOOR DL+LL SURCHARGE OF 2000# WHEEL LOAD @ APPROX. S' FROM WALL — 2.0/6"2 = .056 KSF -- 1' SURi=H. CALCIS PROVIDED FOR: A. 41-6'' HIGH — SHEETS 2 & S B. 61-6" HIGH — SHEETS 4 & 5 i_ONSTRUi=TION DETAIL — SHEET 6 MATERIALS: CONCRETE — ULTIMATE COMPRESS. STRENGTH — f1c 2000 PSI @ 28 DAYS, REINFORCING — ASTM A615, GRADE 4p, WELDED WIRE MESH ASTM A185, 6:.6 — W1.4 W1.4 ( Wl O) , ALLOWABLE SOIL BEARING PRESSURE — 1500 PSF, ALLOWABLE LATERAL DRG. PRESSURE — 200 PSF. FLT ENGINEERING ' PROJECT : HALSTROM CONSTRUCTION 5790 CLARK ROAD JOB NO. : 2171 PARADISE, CA DATE : 10/1992 (916) 872-0254 CALCIS BY : FLT SHEET 2 OF SUBJECT: CONCRETE RETAINING - BEARING WALL WALL DESIGN: ALL CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RATIO: LEVEL SOIL EQUIVALENT FLUID PRESSURE (PSF): 30 SURCHARGE (FEET): 2000# -WHEEL LOAD 1 YIELD STRENGTH REINF. (KSI): 40 ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE (PSI): 2000 GRAVITY LOAD - DEAD LOAD (KIP) 0.11 - LIVE LOAD (KIP) 0.90 OVERALL HEIGHT OF THE WALL_ Hw (FEET): � 4. 5 ��. OVERALL HEIGHT OF THE SOIL - Hr (FEET): 5.17 THICKNESS OF WALL - T (INCHES): 6 COEFFICIENT - a : 1.46 TOTAL EARTH PRESSURE - Fhr (KIP): 0.40 REACTION @ TOP OF WALL - Rt (KIP): 0.15 REACTION @ BOTTOM OF WALL - Rb (KIP): 0.25 HEIGHT OF 10' SHEAR - Ho (FEET): 2.53 MOMENT - Mw (FT -KIP): ' 0.22 AREA REINF. (IN^2) 'dl(IN) SIZE & -------------------------------------------------------- SPA (IN) ' 0.041 3.75 #4 @ 58.7 MIN. VERTICAL REINF. - .15 % (IN^2): 0.108 MIN. HORIZONTAL REINF. - .25 % (IN^2): 0.180 DESIGN REINF. - VER - HORIZONTAL: COMBINED STRESSES @ WALL / 0.13 < 1.0 PROJECT : HALSTROM CONSTRUCTION JOB NO. : 2171 DATE : 10/1992 / CALCIS BY : FLT FOOTING DESIGN: DENSITY OF SOIL (PCF): DENSITY OF CONCERTE (PCF): ALLOW. SOIL BEARING PRESSURE (PSF): ALLOW. LATERAL BEARING PRESSURE (PSF): FRICTION COEFFICIENT - Fc: BEARING PRESSURE REDUCTION (PSF): NET. ALLOW. BEARING PRESSURE (PSF): PRELIM. FOOTING - WIDTH (INCHES): - DEPTH (INCHES): 100 150 1500 200 0.35 0 1500 12.41 ' 6.00 DESIGN FOOTING - WIDTH (INCHES) 12.00 - DEP TOTAL8RAVITY LOAD - Pv (KIP): 1.591 INCREASE OF ALLOW. SOIL PRESSURE (%): 0A ACTUAL SOIL PRESSURE - 0 (PSF): 1509 < 1500 SLIDING RESISTANCE - Fr (KIP): SLAB REINFORCEMENT: ------------------- REINF @ TOP'OF WALL (BAR #): MAX. HORIZONTAL SPAN OF WALL (FEET): . DESIGN HORIZONTAL SPAN (FEET): SLAB THICKNESS (INCHES): SLAB WIDTH REQUIRED (FEET): DESIGN AREA OF SLAB REINF. (IN^2/LF): ALLOW. TENSILE STRESS OF REINF. (KSI): LENGTH OF DOWELS (INCHES): 0.39 > 0.25 4 7.88 4 4 8.77 0.029 24 10.59 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET .3 OF id:l ` PROJECT : HALSTROM CONSTRUCTION JOB NO. : 2171 DATE : 10/1992 CALC'S BY : FLT SUBJECT: CONCRETE RETAINING - BEARING WALL _________________________________ WALL DESIGN: ALL CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RATIO: LEVEL SOIL EQUIVALENT FLUID PRESSURE (PSF): 30 SURCHARGE (FEET): 2000# WHEEL LOAD 1 YIELD STRENGTH REINF. (KSI): 40 ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE (PSI): 2000 GRAVITY LOAD - DEAD LOAD (KIP) - LIVE LOAD (KIP) OVERALL HEIGHT OF THE WALL - Hw (FEET): OVERALL HEIGHT OF THE SOIL - Hr (FEET): THICKNESS OF WALL - T (INCHES): COEFFICIENT - a : TOTAL EARTH PRESSURE - Fhr (KIP): REACTION@ TOP OF WALL - Rt (KIP): REACTION @ BOTTOM OF WALL - Rb (KIP): HEIGHT OF 10' SHEAR - Ho (FEET): MOMENT - Mw (FT -KIP): AREA REINF. (IN^2) 'd'(IN) - SIZE & SPA (IN) ------------------------------------------------ 0.115 3.75 #4 @ 20.9 MIN. VERTICAL REINF. - .15 % (IN^2): MIN. HORIZONTAL REINF. - .25 % (IN^2): DESIGN REINF. - - HO COMBINED STRESSES @ WALL « FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 SHEET 4 OF 'Ag 0.11 0,90 6.5 7.17 � 0- 1. 46 1.46 0.77 0.28 0.49 3.68 0.63 0.108' 0.180 0.32 < 1.0 PROJECT : HALSTROM CONSTRUCTION JOB NOI : 2171 DATE : 10/1992 CALCIS BY : FLT FOOTING DESIGN: DENSITY OF SOIL (PCF): DENSITY OF CONCERTE (PCF): ALLOW. SOIL BEARING PRESSURE (PSF): ALLOW. LATERAL BEARING PRESSURE (PSF): FRICTION COEFFICIENT - Fc: BEARING PRESSURE REDUCTION (PSF): NET. ALLOW. BEARING PRESSURE (PSF): PRELIM. FOOTING - WIDTH (INCHES): - DEPTH (INCHES): ` FLT ENGINEERING 5790 CLARK ROAD ' PARADISE, CA (916) , 872-0254 100 150 1500 200 0.35 ROM 14.01 8,33 DESIGN FOOTING - WIDTH - DEPTH (INCHES): 16.0o TOTAL GRAVITY LOAD - Pv (KIP): 2.06x INCREASE OF ALLOW. SOIL PRESSURE (%): 6.7 ACTUAL SOIL PRESSURE - Q (PSF): 1547 < 1600 SLIDING RESISTANCE - Fr (KIP): SLAB REINFORCEMENT: -------------------- REINF __________________ REINF @ TOP OF WALL (BAR #): MAX. HORIZONTAL SPAN OF WALL (FEET): DESIGN HORIZONTAL SPAN (FEET): SLAB THICKNESS (INCHES): SLAB WIDTH REQUIRED (FEET): DESIGN AREA OF SLAB REINF. (IN^2/LF): ALLOW. TENSILE STRESS OF REINF. (KSI): LENGTH OF DOWELS (INCHES): 0.76 > 0.49 4 5.80 4 4 16.20 0.029 24 19.55 SHEET j OF 49, DY-._..��T DATE..9Z SUGLJECT..TYP/C.4G CONC�G'T�'.- SHEET u0. .._6.. Or..�.... c�•�cD. e� DATE......._FOUND.4T/ONS•__-_J�OR..,-_ .. JOB NO... /l•4LST.eOI'! C`ONSTiPUCT/ON, l`.%40,4 L OAD1116' Pie:7,P Sf/EE r / t-ivIL qlF pf� � o�'`� rh1.4N C ""EXreW.0 YERr, M444 hVrO 6 x 6 'okl m CvRd - �B o • c. Hfx OJC � G ♦ P� d Ile ~Domerz S a If3 o•c, /W g NCOitlC. S414B OR 3eVP `V,4L RE/lV/� r0 S443 "j - G-' 4 4. /3 ,v a, HOei2 - TYRICA ,L C A. f Af COO COMPACTS • BAC',rF�LL A: 2 CC EA, A. f54G'F - O "CG F4R iV, 4TU)t/!G CR.¢OF -1 OTC • �� CoWT. -� / � DOWELS TOrIATCf/ f'CRT, � AIA t- L Re WR - 0P7 -1011,¢L � /Z ,4, GAP SPG/CE P¢ HIM 1=0(,I ./1 A.T/O/V DFTA/ - ti r. S, NOTe ,' eeov/DF SHOA!z-lt/G O>=r COit/C. 1 x4e- U�S/T/L rhl& COA/C. OP SLAB /S C!/RCO. LrIP 8012/2. �eelll^ /8 �'�''!/N. - 57 T 90 MARK PARADISE,- gWgM872-0254 COUNTY OF OUTT9 BUILDING DEPT DEC 16 1992 STRUCTURAL F'. A L C U L A T 1 0 N S -FOR CANTILEVERED RETAINING WALL BUM =NYT NG DEPARTHEM. HALSTROM CONSTRUCTION APPROVED i P.0. BOX 545' -Z:-- MAGALIA, --..'A 95954 i-:ALi--':UL-AT IONS ARE IN COMPLIANC-E WITH THE 1991 EDITION OF, THE UBI--' SIGNED DATE FRANV` L. TYUI-::'OS, RCE 31-2434 F L T ENGINEERING i--:LAF,[::' F.OAD PARADISE, '--:A � - r... ... 11 . - 1.) to, I 'MUW ;,Tf ub TMI.MV,4490 omalltm 0"? V O'P q q A . FLT RING SUBJECT: CONC. CANTILEVER RETAINING WALL 5790 CLARK ROAD PARADISE, CA BY: FLT' DATE: 12/92 JOB NO.: 2189 PROJECT: HALSTROM CONSTRUCTION SHEET 1 OF 4 P.O. BOX 545, MA6ALIA, CA 95954 . DESI6N_CRITERIA�L ' STUD WALL, ROOF AND FLOOR ARE SUPPORTED BY CONCRETE CANTILEVER RETAINING WALL FOUNDATIONS. CODE 1991 UBC SUPERIMPOSED LOADS: ` MIN. DL = .010 x (3+8) = .11 k/l MAX. LL = .0306 x 16 + .010 x (16-3) + .050 x 10 = 1.11 k/l LOADING PER ABOVE IS CRITICAL FOR BOTH — BEARING (INCLUDES DL+LL) AND SLIDING RESISTANCE (MIN. DL ONLY), . MAX. LL — ROOF SNOW + ADD'L LIGHT ROOF DL + FLOOR DL+LL CALCIS PROVIDED FOR: 4'-6" HIGH WALL — SHEETS 2 & 3 CONSTRUCTION DETAIL — SHEET 4 MATERIALS: ~' CONCRETE — ULTIMATE COMPRESS. STRENGTH — f'c = 2600 PSI @ 28 DAYS, REINFORCING — ASTM A615, GRADE 40, ALLOWABLE SOIL BEARING PRESSURE — 1500 PSF, ALLOWABLE LATERAL BRG. PRESSURE — 200 PSF T-1 t - � PROJECT e HALSTROM CONSTRUCTION JOB NO. . 210-3 DATE . 12/1992 SUBJECT: CONCRETE CANTILEVER RETAINING WALL. WALL_ DESIGN ------------ AL..L. CALCULATIONS ARE IN UNITS/LN. FT. GRADE SLOPE RATIO: LEVEL SOIL EOU I VALENT FLUID PRESSURE (PSF)o 30 SURCHARGE (FEET): i i YIELD STRENGTH REINF... (KSI): 40 ULTIMATE COMPRESSIVE 0TRENGTH OF CONCRETE (PSI): 2000 � GRAVITY LOAD — DEAD LOAD (KIP): — LIVE LOAD (KIP) OVERALL HEIGHT OF THE WALL — H (FEET): OVERALL HEIGHT OF THE SOIL -- Hr (FEET): THICKNESS OF WALL — TOP (INCHES)g — BOTTOM (INCHES): COEFFICIENT - TOTAL EARTH PRESSURE Fw (KIP)- MOMENT — Mw (FT—KIP: e 4.5 4.5 G ra 1146- 0.24 0.32 FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (91 t=om ) 872-0254 SHEET 2 OF '?- AREA REINF. (IN"2) ' ldl CIN: SIZE & SPA (IN) ------------------------------------------------- .058 3.75 #4 @ 41. MIN. VERTICAL REINF. — .15 % (IN�24 MIN. HORIZONTAL_ REINF. -- .25 l C IN�2) — 0.180 DESIGN REINF. -- VERTICAL: #4 @ 2-1. — HORIZONTAL: #4 @ 13 COMBINED STRESSES @ WALL., 0.18 < 1 . o FOOTING DESIGN: ----------------- DENSITY OF SOIL_ CPCF i e 10Ci DENSITY OF i :ONCERTE (PCF): 150 OVERTURNING RATIO - MIN. 1.5 — MAX- 2.5 ALLOW. SOIL BEARING PRESSURE (PSF ) e 150o i ALLOW. LATERAL BEARING PRESSURE (PSF ) e 200 FRICTION COEFFICIENT — Fc: 0. 35 � " � PROJECT : HALSTROM CONSTRUCTION JOB NO. : 2189 DATE : 12/1992 CALCIS BY : FLT FLT ENGINEERING 5790 CLARK ROAD PARADISE, CA (916) 872-0254 " . SHEET 3 OF DESIGN FOOTING DEPTH (INCHES): 12 DESIGN FOOTING WIDTH -HEEL (INCHES): 4 FOOTING KEY - DEPTH - BACK TO BACK OF WALL INCHES) 20 TOTAL WIDTH OF FOOTING (INCHES)i 26 OVERTURNING FORCE - Fo (KIP): 0.38 OVERTURNING MOMENT - Mo (FT -KIP): 0.63 TOTAL RESISTING WEIGHT - W (KIP): 0.94 RESISTING MOMENT - Mr (FT -KIP): 1.34 OVERTURNING RATIO - SF . ' 2.14 NET MOMENT - Mn (FT -KIP): 0.71 ECCENTRICITY - e (FEET): 0.33 ECCENTRIC MOMENT - Me (FT -KIP): 0.31 FOOTING AREA - Af (FT^2): ' 2.17 SECTION MODULUS - S (FT^3): ' 0.78 SOIL PRESSURES - DL ONLY - SPt (PSF): 831.95 < 1500 - SPh (PSF): 38.82 > 0 SOIL PRESSURES - ADDED LL - SPt' (PSF): 634.91 < 1500 - SPh' (PSF): 1260.47 > 0 SLIDING RESISTANCE - Fr (KIP): 0.56 >.0.38 . FOOTING - WE: ' EARTH PRESSURE @ TOE - Fv (KIP): 0.78 MAX. MOMENT@ TOE - Mt (FT -KIP): 0.59 AREA REINF. (IN^2) 'dl(IN) SIZE & SPA (IN) ^ ________________________________________________ 0.046 8.75 #4 @ 51.7 DESIGN TOE �' SUejECT NT/L..................SHEET NO.... CHKO. BY....... DATE -------- - - �t7 ----------- JOB NO ------- 21169 ............ .... � &.44,9r&40,V CONST.. M44PA.11A. C,4. 6 44,0Z,057 swFEr / Q�pE L.Ty lF2 0 cv mNo. A 3 4 A40A'^141- d 13 C gv'vo.c. Y67er. mwue'41- a�e440c- OR CO//C, 15'e -Az -/(g// 4rle1,re.0e%1 r- cowr m AO/C' Arle,5 A 2. T4 '7 46' -KC'CO3V7- CONC.it'6Y' 4,4,= 110,RIZ. 4-.D elf - Pow& -z -s e 7-4) . . . IF LcT EMOMMENUM 5790 CLARK RD., PARADISE, CA. 95969 (916)872-0254 F. H. t.isr nNLY Hot Plan Attached • ee� 1:1 r Han All.chcd TO: .�Builhdin; Department FROM: Environmental Health SUBJECT: Sanitation Clearance Owner Water Plan Approved for: Sewage Disposal Water Supply: ? Public _ Clearance for bedroom i\home. Other �� x �l ©� (q --F Hold final for:' Final clearance O.K. for: NOTE: �—? Environmental Health pecialist r . 8/92 MY -M O o s AP#t '— Private Well 1 -') • qL Date Certificate of Compliance: Residential Climate Zone 11 Project Title Project Address BUILDING DATA Conditiosled o�I Area S=P=X sed Floor tT Single Family Detached (SFD) [ ] Single Family Attached (SFA) [ ] Multi -Family (MF) Number of Stories Number of Units [ I Addition.Alone [ ] Existing Building [ ] Existing -Plus -Addition BUII.DING SHELL INSULATION Component Insulation Locatiion/Commem Tym R -Value (attic. to smage. typical. Wall ..............( Roof ............. Roof ............. Floor ............. Floor ............. Slab Edge..... GLAZING /w /'f _ 2✓ Buming pamit M A S Chedced By/ Date Entofternent Agency Use Only Glass Area % Glass North o"L!v Type Oufiwe, air . East fQ'r __1, • r South West_ Skylight Total , Glaring Area Glass Type Shading Devices Interior Exterior Overhang Framing Type North D 45�-- North ( ) East ( ) qh East ( ) South ( ) oZ Sou th ( ) West ( )� West ( ) Skylight....... THERMAL MASS Type/Covering Area Thickness (slab/exposed, tile. etc.) (SO (inches) Location/Description (kitchen, bath. etc.) Duct Location Duct Output Manufacturer / Model # (attic, etc.) R -Value tuh or approved al � � �- % �7 N —7,�— �, Maximum Furnace Heating Output: Btuh� HOT WATER SYSTEMSTank Manufacturer/Model # System Type (storage gas eta) Capacity (or approved equal) SneliAli eature(s) Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildingsorb" to Ute Standards must contain these meawres re8adless of the compliance approach used. Items marked with asterisk (•) may be superseded by more strin8ent eomplianoe regatrerrtarts listed on the Certificate of Compliance. this checklist is incorporated me the permit doetunens. the features noted shall be considered by all parties as binding inimtun component pertomurtcespeafratiors for the mandatary measures whether they are shown elsewhere in cots or on this h.U, only. DFSCRIPRON DESIGNER ENFORCEMENT Building Envelope Measures • §2.5352(a): Minimum ceiling insulation R-19 weighted avenge. §2.5352(b): Loose fall insulation manufacturer's Label\ R.Value. • §2.5352(c): Minimum wall insulation in framed walls I I weighted avenge (does not apply to exterior mass walls). §2-5352(kr Slab edge insulation - water absorption rate no greater than 0.3%. water vapor transmission rate no greater than 2.0 pcm%1mch. 62.5311: insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. 62.5352(p: Vapor barriers mandatory in Climate Zones 14 and f6 only. 12.5317: Inftltration/Exftltration Controls a Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped. all joints and penetrations caulked and soled 62-5352(e): Special infiltration barrier installed to comply with 62-5351 meets CEC quality standards. §2.5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: L Tight fitting. closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures 12-5352(8) and 2-5303: Space conditioning equipment siring: attach calculations. §2-5352(h) and 2.5315: Setback thermostat on all applicable heating systems. • 12-5316(a): Ducts constructed. installed and insulated per Chapter 10, 1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2.5314(c): Gas -rued space heating equipment has intermittent ignition devices. 62.5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. ;2.5352(1): Water heater insulation bLvaa (R-)2 or greater) or combined interiorkxterior insulation (R-16 or greater): first 5 feet of pipes closest to tank insulated (R-3 or veater). §2.5312(Exception 1): Pipe insulation on steam and steam condensate return & recirculating piping. §2-5319(d): Swimming Pool Heating I. System has: a. On/off switch on heater. b. Weatherproof instruction plate on Anter. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and Appliance Measures 62.53520): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. §2.5314(c): Gas fired appliances equipped with intermittent ignition devices. 12-5314(a): Refrigerators. refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. COMPLIANCE STATEMFdVT This CertiflCM of compliance lists the binding features and performance specifications needed to comply with Title 24. Chapter 2-53 and Title 20. Q aptcr 2. Subchapter4. Article 1 of the California. Administrative code. 'Ibis certificate has been signed by the individual with overall design responsibility and the building owner. who shall Main a Copy of it and transmit the Certificate to any subsequent purdiaser of the building. Designer NWM Titk/Finn: Adger: Tekpho= Lie. I: (signature) A / • CC �. Documentation Author Name: SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) 75tWFum: Address: (date) Building Owner Addma:i %/1—, caz- 7T737 Telephorm Enforcement Agency Noma: Ag wr. Tekomm Minimum. HVAC SYSTEMS Type Oufiwe, air . -Efficiency conditioner, heat pump) (SE, SEER.HSPF) Duct Location Duct Output Manufacturer / Model # (attic, etc.) R -Value tuh or approved al � � �- % �7 N —7,�— �, Maximum Furnace Heating Output: Btuh� HOT WATER SYSTEMSTank Manufacturer/Model # System Type (storage gas eta) Capacity (or approved equal) SneliAli eature(s) Mandatory Measures Checklist: Residential MF -1R NOTE: Lowrise residential buildingsorb" to Ute Standards must contain these meawres re8adless of the compliance approach used. Items marked with asterisk (•) may be superseded by more strin8ent eomplianoe regatrerrtarts listed on the Certificate of Compliance. this checklist is incorporated me the permit doetunens. the features noted shall be considered by all parties as binding inimtun component pertomurtcespeafratiors for the mandatary measures whether they are shown elsewhere in cots or on this h.U, only. DFSCRIPRON DESIGNER ENFORCEMENT Building Envelope Measures • §2.5352(a): Minimum ceiling insulation R-19 weighted avenge. §2.5352(b): Loose fall insulation manufacturer's Label\ R.Value. • §2.5352(c): Minimum wall insulation in framed walls I I weighted avenge (does not apply to exterior mass walls). §2-5352(kr Slab edge insulation - water absorption rate no greater than 0.3%. water vapor transmission rate no greater than 2.0 pcm%1mch. 62.5311: insulation specified or installed meets California Energy Commission (CEC) quality standards. Indicate type and form. 62.5352(p: Vapor barriers mandatory in Climate Zones 14 and f6 only. 12.5317: Inftltration/Exftltration Controls a Doors and windows between conditioned and unconditioned spaces designed to limit air leakage. b. Doors and windows certified. c. Doors and windows weatherstripped. all joints and penetrations caulked and soled 62-5352(e): Special infiltration barrier installed to comply with 62-5351 meets CEC quality standards. §2.5352(d): Installation of Fireplaces 1. Masonry and factory -built fireplaces have: L Tight fitting. closeable metal or glass door b. Outside air intake with damper and control c. Flue damper and control 2. No continuous burning gas pilots allowed. HVAC and Plumbing System Measures 12-5352(8) and 2-5303: Space conditioning equipment siring: attach calculations. §2-5352(h) and 2.5315: Setback thermostat on all applicable heating systems. • 12-5316(a): Ducts constructed. installed and insulated per Chapter 10, 1976 UMC. §2-5316(b): Exhaust systems have damper controls. §2.5314(c): Gas -rued space heating equipment has intermittent ignition devices. 62.5314: HVAC equipment, water heaters, showerheads and faucets certified by the CEC. ;2.5352(1): Water heater insulation bLvaa (R-)2 or greater) or combined interiorkxterior insulation (R-16 or greater): first 5 feet of pipes closest to tank insulated (R-3 or veater). §2.5312(Exception 1): Pipe insulation on steam and steam condensate return & recirculating piping. §2-5319(d): Swimming Pool Heating I. System has: a. On/off switch on heater. b. Weatherproof instruction plate on Anter. c. Plumbed to allow for solar. 2. 75 percent thermal efficiency. 3. Pool cover. 4. Time clock. 5. Directional water inlet. Lighting and Appliance Measures 62.53520): Lighting - 25 lumens/watt or greater for general lighting in kitchens and bathrooms. §2.5314(c): Gas fired appliances equipped with intermittent ignition devices. 12-5314(a): Refrigerators. refrigerator -freezers, freezers and fluorescent lamp ballasts certified by the CEC. Indicate make and model number. COMPLIANCE STATEMFdVT This CertiflCM of compliance lists the binding features and performance specifications needed to comply with Title 24. Chapter 2-53 and Title 20. Q aptcr 2. Subchapter4. Article 1 of the California. Administrative code. 'Ibis certificate has been signed by the individual with overall design responsibility and the building owner. who shall Main a Copy of it and transmit the Certificate to any subsequent purdiaser of the building. Designer NWM Titk/Finn: Adger: Tekpho= Lie. I: (signature) A / • CC �. Documentation Author Name: SPECIAL FEATURES/REMARKS (Add extra sheets if necessary) 75tWFum: Address: (date) Building Owner Addma:i %/1—, caz- 7T737 Telephorm Enforcement Agency Noma: Ag wr. Tekomm 1. Ceiling Insulation F2 factor 0.90 Number of staries 3 -1 R -value One Two Three R-0 -103 -9 32 R-19 -8 -4 -2 R-30 -2 -1 -1 R-38 0 0 0 U -value -24 -10 4 0.50 -176 -84 -54 0.30 -102 -49 32 0.10 -26 -13 -8 0.08 -18 -9 -6 . 0.06 -11 -5 -4 0.04 -4 -2 -1 0.02 4 2 1 0.00 11 5 3 1. Wall Insulation 5 13 27 • Single- Single - -9 -2 Family Family Multi - R -value Detached Attached Family R-0 -68 -51 -34 R-11 0 0 0 R-13 2 2 1 R-19 8 6 4 U -value -40 -11 -4 0.80 -153 -114 -76 0.50 -91 -68 -46 0.30 -47 -36 -24 0.10 0 0 0 0.08 4 3 2 0.06 9 7 5 0.04 14 11 7 0.02 19 14 10 0.00 24 18 12 12 16 17 -23 I. Raised Floor Insulation 3 8 Insulation In Floor 16 -20 Number of stories 9 R -value One Two Three R-0 -17 -8 -5 R-11 -3 -2 -1 R-19 0 0 0 R-30 3 1 1 U -value 15 18 12 0.60 -144 -70 -46 0.50 -120 -58 38 0.40 -95 -46 30 0.30 -69 -34 -22 0.20 -43 -21 -14 0.10 -17 -8 -5 0.08 -11 -6 -4 0.06 -6 -3 -2 0.04 -1 0 0 0.02 4 2 - 1 0.00 10 5 3 Controlled Ventilation Crawlspace 1 Number of stories 1 R -value One Two Three R-0 -11 -7 -5 R-5 -4 -4 3 R-11 -2 -2 -2 R-19 -1 -2 -2 Slab Edge Insulation 8 7 6 5 4 Number of Stories 0.85 7.79 R -value One TWO Three • R-0 0- 0 0 R-5 8 5 2 R-7 8 6 .3 F2 factor 0.90 -4 3 -1 0.80 -1 -1 0 0.70 2 2 1 0.60 6 4 2 0.50 9 6 3 0.40 12 8 4 S. Infiltration (Air Leakage) specification Points Standard _ 0 6. Glass Heat Loss Total SCORE CARD b. Interior .. U -value y. Glass Percent East South .51 to .41 to .31 to 0.30 or Glass Single Double .60 .50 .40 less 50 -121 -53 -39 -24 -10 4 40 -90 37 -26 -14 3 8 35 -75 -29 -19 -9 1 10 30 -61 -21 -13 .4 4 12 29 -58 -20 -12 -3 5 12 28 -55 -18 -10 -2 5 13 27 • -52 -17 -9 -2 6 •13- 26 -49 -15 -8 -1 7 i4 25 -46 -14 -7 0 7 14 24 -43 -12 -5 1 8 14 23 -40 -11 -4 2 8 15 22 -37 -9 -3 3 9 15 21 34 -7 -2 4 10 15 20 -31 -6 0 5 10 16 19 -29 -4 1 6 11 16 18 -26 -3 2 7 12 16 17 -23 -1 3 8 12 17 16 -20 0 4 9 13 17 15 -17 1 6 10 14 17 14 -14 3 7 10 14 18 13 -12 4 8 11 15 18 12 -9 6 9 12 15 19 11 3 7 10 13 16 19 10 -3 9 11 14 17 19 9 -1 10 13 15 17 20 8 2 12 14 16 18 20 7. Shading (Shade Open) EtfedHe Peroatt GI&= (percent glass x SC) -ffectW SCORE CARD b. Interior Slab Floor ` Raised Floor y. Glass North East South West Skylight 18 5 1 4 1 na 16 4 2 5 1 na 14 4 2 5 1 na 12 3 3 5 2 na 11 3 3 5 2 na 10 2 3 5 2 1 9 2 3 5 2 2 8 2 3, 5 2 2 7 1 3 4 2 2 6 1 3 4 2 3 5 1 2 4 2 3 4 0 2 3 1 3 3 0 1 2 1 3 2 0 0 1 0 3 1 -1 -1 -1 -1 2 0 -1 -2 -4 -2 0 is = not allowed 7.0 6 9 11 13 13 �B. Shading (Shade Closed) 7.5 6 10 Effective Peremt Glass 14 14 (pest:ut tlaec x SC) 11 13 %Glow _ Nodi but t cuh West SlWW 18 -14 -48 -69 -64 na 16 -12 -42 -59 -55 na 14 -10 35 -50 -46 na 12 -8 -29 -40 -37 na 11 -7 -26 36 -33 na 10 -6 -23 31 -29 -74 9 -5 -20 -27 -25 -65 8 -5 -17 -23 -21.. -56 7 -4 -14 -19 -18 -47 6 3 -11 -15 -14 -38 5 -2 -9 -11 -10 30 4 -1 3 -8 -7 -23 3 0 -4 -5 -4 -16 2 1 -1 -2 -1 -9 1 1 1 1 1 -4 0 2 3 4 3-- 0 na - not allowed - 0.72 6.60 0 0 0 0 9. Interior Thermal Mass SCORE CARD b. Interior Slab Floor ` Raised Floor brass Sbrres -4 Stones -3 'ICFA One Two Three One Two Three 0.0 -8 -5 -4 -2 -1 -1 0.1 -8 -5 3 -1 0 0 0.3 -7 -4 -2 0 1 1 0.5 -6 3 -1 1 1 2 0.7 -5 -2 -1 1 2 2 0.9 -5 -1 0 2 3 3 1.1 -4 -1 1 3 4 4 1.3 -3 0 2 3 4 5 1.5 -3 1 2 4 5 5 20 -1 2 4 5 6 7 25 0 3 5 7 7 8 3.0 1 4 6 8 8 9 3.5 2 5 7 9 9 10 4.0 3 6 8 9 10 10 4.5 3 7 8 10 11 11 5.0 4 7 9 11 12 12 5.5 5 8 9 11 12 12 6.0 5 8 10 12 13 13 6.5 6 9 10 12 13 13 7.0 6 9 11 13 13 14 7.5 6 10 11 13 14 14 8.0 7 10 11 13 14 14 8.5 7 10 12 13 14 15 10. Exterior Wall Thermal Mass -5 Exterior Suplo- suvie- -2 7.0 WaA Family Fanuly Multi Mass Detaehed Attached Family 5 0.00 0 0 0 14 12 0.20 3 2 1 22 0.40. 5 4 3 11.0 0.60 8 6 .4 8 0.80 10 8 5 14 . 1.00 13 10 7 20 1.20 13 12 8 2109 1.40 12 13 9 4 1.60 10 13 11. Solar 1.80 10 12 12 3 2.00 10 11 13 3 11. Heating System _ 2 5.3 WSB 9 SE or l3SPF 2 2 (assumes duets In attic) POU 9 5 Sum of 14; 2 2 SE -25 or -24 to -14 to -4 to +6 to 16 or SE HSPF less -15 -5 +5 +15 more 0.72 6.60 0 0 0 0 0 0 0.75 6.88 3 3 3 2 2 1 0.80 7.33. 8 7 6 5 4 3 0.85 7.79 13 11 10 8 7 5 0.90 8.25 17 15 13 11 9• 7 0.95 8.71 __20 18_=15_ 13 11 8 5.6 Effective SE or HSPF 6 (SE or HSPF x duct efficiency) 2 EBectm -25 or ,24 b -14 b 4 to +6 b 16 or SE HSPF loss --15 3 +5 4:15 more 0.30 275 -73 -64 -56 -47 38 -30- na 3.41 35 -39 -34 -29 -24 -18 0.40 3.67 -34 -30 -26 -22 • -18 -14 0.50 4.58 -10 -9 -8 -7 -5 -4 0.56 5.13 0 0 0 0 0 0 0.60 5.50 5 5 4 3 3 2 0.70 6.42 17 15 13 11 9 7 0.80 7.33 25 22 19 16 13 10 0.90 8.25 32 28 24 20 17 13 1.00 9.17 37 32 28 24 19 15 Zonal Control Adjustment 1.4 System Type 1.8 2 22 25 Resistance 10 9 7 6 4 3 Other 6 5 4 3 2 2 12. Cooling Syst m SCORE CARD b. 1 1. Ceiling Insulation SEER -5 -4 -4 -3 -2 (assume; ducts In attic) 3 3 .. 2 Stm of 7-10 2 1 Single -Family Iktadled and Attached -25 or -24 to x1410 -4 b 46 to 16 Or SEER less 45 .6 45 +15 more 8.0 -14 -12 -10 -8 -6 -4 8.5 -9 -7 -6 3 -4 3 8.9 -5 -4 -4 3 -2 -2 9.0 -4 3 -3 -2 -2 -1 9.5 0 0 0 0 0 0 10.0 4 3 3 2 2 1 10.5 7 6 5 4 3 2 11.0 10 9 7 6 4 3 12.0 15 13 11 9 7 5 13.0 20 17 14 12. 9 6, -1 0 Etradve SEER 4.8 -HWR -18 (SEER xdud elTidenc7) -9 -7 3 - Stan of 7-10 WSB.-: -25 -16 Effective -25 or -24 to -141* -41* 46b 16w SEER fess -15 -6 45 +15 more 5.0 -30 -25 -21 -17 -13 -9 6.0 -12 -11 -9 -7 3 -4 6.6 -5 -4 -4 3 -2 -2 7.0 0 0 0 0 0 0 8.0 9 8 6 5 4 3 9.0 16 14 12 9 7 5 10.0 22 19 16 13 10 7 11.0 26 23 19 15 12 8 l 12.0 30 26 22 18 14 . 9 13.0 33 29 24 20 15 10 1100_ Zonal Control Adjustment 2109 111 10 8 7 6 4 3 0 No Coolin; System Installed Solar 14 .`Stories SCORE CARD b. 1 1. Ceiling Insulation One -5 -4 -4 -3 -2 -2 Two+ 3 3 .. 2 2 2 1 Single -Family Iktadled and Attached 10. Exterior -Wall Mass , ` Unit Size (sQ Water :199 120.9 1700 2200 2700 Heater uredii or .1 b to to • or Type Type less,11699 2199 2699 more SG None -0 0 0. 0 0 or Solar 12 '' 8 6 5 4 - HP -HWR 8 5 4 3 3 8S% WS8 5 3 3 2 2 0.4 POU 8 5 4 3 _ •3 _ SE None 37 -24 -18 -15 -12 3.4 Solar -1 -1 -1 0 0 4.8 -HWR -18 -12 -9 -7 3 - 0.8 WSB.-: -25 -16 -12 -10' -8 23 POU _40 __12 -9 -7. -6 IG None "-5 3 -2 -2 -2 5.2 Solar Z 5- .4 3 2 1.2 POU 3_ 2 1 1 1 1E None -28 :19 -14 -11 '_9 - Solar 8 5 14 3 3 56 POU -10 3 -5 -4 -3 1.6 Multi-Falalq (Individual units) 22 Water 26 699 MO 12 0 (`17M 2200 Heater Orem or b b 10 Or TYPO Type lest 1100_ 11699 2109 111 SG None 0 0 0 0 0 or Solar 14 7 5 4 3 HP HWR __9 4.3 5 3 2 _ 2 5.3 WSB 9 4 3 2 2 1.3 POU 9 5 3 2 2 SE None -45 -23 -15 -it 19 42 Solar 2 1 1 0 0 5.7 HWR -23 -12 -8 -6 '-5 1.6 WSB -25 -13 -8 -6 --5 _ POU -23 -12 8 6 4.1 IG None.. 3 Solart3..6 -4 - -3 2 _-5 -2 5.6 5.8 6 3 2 1 1 - _ POU -• -73o -1 0- --is 0 0 2.7 IE None 3.3 -10 -8 -6 4.4 Solar: 18 9 6 4 4 - - POU -8 ^ T'-4 - -3 - -2 -2 _ . Interior Mass/CFA n►L I K"SJcwrpetod SCORE CARD b. 1 1. Ceiling Insulation . West R -value [38] U -value [0.030] 2. Wall Insulation l --t) or a.. R -value [ 11] U -value [0.098] 3. Raised Floor Insulation or c. R- ue [ 191 U -value [0.037] d. West e. Skylight 9. Interior Thermal Mass 10. Exterior -Wall Mass , I1.Hetse•..1) slab) t TYPE I MASS (UIIIC a 4.2. ie: exposed slab) 0% 5% 10% 15% 20% 25% 30% 35% 40% 45% 50% 55% 60% 6516 70% 75% 60% 8S% 90% 95% 100% 105% 110% 115% 120% 125- 0% 0 0.2 0.4 04 0.6 1.1 1.3 1.5 1.7 1.9 21 2.3 25 2.7 29 3.2 3.4 3.8 31 4 4.2 4.4 4.6 4.8 S 53 10% 0.2 0.4 0.6 0.8 1 1.2 1A 1.6 1.9 21 23 2S 2.7 2.9 3.1 3.3 3S 3.1 4 4.2 4.4 4.6 4.6 S 5.2 54 20% 0.3 0.6 0.8 1 1.2 1.4 1.6 11 2 22 24 27 29 3.1 3.3 3.5 3.7 3.9 4.1 4.3 4.5 4.8 5 5.2 5.4 56 30% 0.5 0.1 0.9 1.1 1.4 1.6 1.8 2 22 24 26 28 3 3.2 3.5 3.7 3A 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.6 So 40% 0.7 0.9 1.1 1.3 1.5 1.7 1.9 2.2 24 26 2.8 3 3.2 3.4 3.6 3.6 4 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 59 .50% 0.9 1.1 1.3 1.5 1.7 1.9 21 23 2.5 27 3 32 3.4 3.6 ae 4 42 4A 4.6 4.8 5.1 5.3 5.5 5.7 5.9 6.1 SS% 0.9 1.1 1.4 1.6 1.8 2 2.2 24 2.6 28 3 32 3.5 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 S.3 5.6 5.8 6 6.2 60% 1 12 1.4 1.7 1.9 21 23 2.S 2.7 2.9 3.1 3.3 3.5 3.8 4 4.2 4.4 4.6 4.8 S 5.2 5.4 5.6 5.9 6.1 63 65% 1.1 1.3 1.5 1.7 1.9 22 2.4 26 2.8 3 3.2 3.4 3.6 3.8 4 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.1 64 70% 1.2 1.4 1.6 1.8 2 22 25 27 2.9 3.1 13 15 3.7 3.9 4.1 4.3 4.6 4.8 5 5.2 5.4 5.6 50 6 6.2 64 75% 1.3 1.5 1.7 1.9 21 23 25 27 3 9.2 3.4 3.6 3.8 4 4.2 4.4 4.6 4.8 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 80Y. 1.4 1.6 1.8 2 22 2.4 26 2.8 3 3.3 15 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 54 5.6 5.8 6 6.2 64 66 85%1.4 1.7 1.9 2.1 2.3 25 2.7 2.9 3.1 3.3 3.5 3.8 4 4.2 4.4 4.6 4.8 5 5.2 54 5.6 5.9 6.1 6.3 SS 6 7 90%' 1.5 1.7 2 2.2 24 26 2.8 3 3.2 3.4 9.6 9.8 4.1 4.3 4.5 4.7 4.9 S.1 53 5.5 5.7 5.9 6.2 6.4 66 68 95Y. 1.6 1.8 2 22 2S 27 2A 3.1 33 3.5 3.7 3.9 4.1 4.3 4.6 4.8 5 5.2 S.4 5.6 5.8 6 6.2 6.4 6.7 6.9 100% 1.7 1.9 21 2.3 25 28 3 3.2 3.4 3.8 3.8 4 4.2 4.4 4.6 4.9 5.1 5.3 SS 5.7 5.9 6.1 6.3 6.5 6.1 7 105% 1.8 2 22 2.4 2.6 28 3 3.3 3S 3.7 3.9 4.1 4.3 4.5 4.7 4.9 5.1 5.4 56 5.6 6 6.2 6.4 6.6 68 7 110% 1.9 21 2.3 23 27 29 3.1 3.3 3.6 3.8 4 4.2 4.4 4.6 4.8 5 5.2 5.4 5.7 SA 6.1 6.3 6.5 6.7 69 7.1 115% 2 22 2.4 2.8 28 3 3.2 3.4 3.6 3.8 4.1 4.3 4.5 4.7 4.9 5.1 5.3 5.5 5.7 5.9 6.2 6.4 8.6 6.8 7 72 120% 2 2.3 2.5 2.7 29 3.1 3.3 3.5 3.7 3.9 4.1 4.4 4.6 4.8 S 5.2 S.4 5.6 58 6 6.2 6.5 6.7 6.9 7.1 73 125% 21 2.3 25 28 3 3.2 3.4 3.6 3.8 4 4.2 4A 4.6 4.9 5.1 5.3 5.5 5.7 5.9 6.1 6.3 6.5 6.7 7 7.2 7.4 Point System Summary: Climate Zone 11 SCORE CARD b. East Measures 1. Ceiling Insulation y> or West R -value [38] U -value [0.030] 2. Wall Insulation l --t) or a.. R -value [ 11] U -value [0.098] 3. Raised Floor Insulation or c. R- ue [ 191 U -value [0.037] 4. Slab Edge Insulation S. Infiltration 6. Glass Heat Loss 7. Shading (Shade Open) a. North b. East c. South d. West e. Skylight S. Shading (Shade Closed) a.. North. b. East c. South d. West e. Skylight 9. Interior Thermal Mass 10. Exterior -Wall Mass , 11. Heating System Zonal Control? ( Y / N ) 12. Cooling System Zonal Control? ( Y / N ) 13. Water Heating or it -value [0] F3 factor [0.77] Standard 15, Type [double] U -value [0.65] % Tour Glass [ 16] % Glass SC Eff. % G X � /. 7 X = X = _X Point Scores D 0 O O Sum 1.6 % Glass SC / Eff. % Glass / X -� 2_ X = / , ! X TYPE 1 MASS AREA Interior MI COND. FLOOR AREA ` TYPE 2 MASS AX AA _ B CO Exterior Wall Mus N- . R A Sum f- X - --' SE or HSPF Duct Efficiency [0.78] Effective SE or [0.7216.6] HSPF [OSN5.15] ,r 0 - Point Total:_ _0001� X = SEER [9.5] Duct Efficiency [0.74] Effective SEER [7.03] Type [SG] Credit (nate]