Loading...
HomeMy WebLinkAbout064-780-035064=780=035-x• 94' 04"32B P, E M %,� w7 BASHAM', URSULA �.. V 14365 TROY WAY; MAGALIA L CONT:, MIKE-RUTLEDGE q NEW SINGLE FAMILY � r 4 i a ° o S PA- RESIDENTIAL f c 064-780-035 94-0432B,P,E,M BASHAM, URSULA 14365 TROY WAY, MAGALIA CONT: MIKE RUTLEDGE NEW SINGLE FAMILY V=OK 0 = Not OK Not = Not Readyble MOBILE -HOMES ' Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'a 1. Zoning Requirements -Setbacks -Easements 2. Soils; Special MH Support Sketch 3. Sewer; Location -Test -Fall -C/0 Concrete 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete 6. Sas; Location -Test -Wrap: / /" L'Yt. /"Net. or/ P'L"ft./ /"LPG 7. Well Clearance & Disconnect 8. 'Utility Clearance Date/Initials MOBILE HOME INSTALLATION (Plans) OK except #'s 1 Zoning Requirements -Setbacks Easements 2 Footings; Size -Spacing -Marriage Line a. Gas; MH Teat -Demand -Valve -Connector A. Electricity; MH Teat -Crossovers -Breakers -Clearances S. Drain; MH Test -Fall -Flex Connector 6. Water; MH Test -Regulator -Connector -7. Water and Sewer Connected -C/O to Grade -HD Approval 3. Gas and Electricity Tagged B. Exits; Insp.-Sketch 40. Cert. of Occupancy 1 t MISCELLANEOUS Date/Initial DECKS, COVERS, CARPORTS, GARAGES, (Plans)OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel, 3. Decks; Griders and/or Joists-Decking-Bracing-Stairs-Raila 4. Wood Awn.; Posts-Beams-Rftrs -Connectors Shthg.-Rig.-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg; Sils-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh \ . 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings Date/Initials POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distances-GFI 5. Elec.; Pool Lighting; 15 volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes-Enclosures-PaneIboa rds-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test-Water'Supply Test V=OK O = NOOK - = Not Applicable = Not Ready Date/Initials UNDERFLOOR (Plans) OK except #'a RESIDENTIAL• (Single & Duplex) 42' M., Mein; Soils-Elec. OFFIU /►4f' FIR. Depth . Fes., Garage; Soils-Steel-Elec. G d.-AZP Ftg. Depth 1, Fsg., Porches & Decks; Soils-Steel-t?/Ftg. Depth fn? -Ali _ ra VStemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab; Steel -Wrapped 8. Pjgrs-Fireplace Ftg.-Steel V.; Fell -Fitting -Test -2 Way C/0 -Sewer Test Gas Pipe; Size -Anchors - yard gas piping: size -test Q1 Water Pipe; Test -Anchor -Regulator -Service Test 12. Pienums & Ducts; Clearance -Material -Su W. Access & Ventilation 16. Insulation Date/Initials PLU ING Permit except #'s ater Htr e - ccess-Combustion Air -Baffle ?ter Pipe; est & Anchor -Nail Protection D.W.V.; Test -Fittings & Anchor -Nati Protection 19r9hower Pan; Test, First Floor -Tub Access Z_XL20. Test Tub & Shower, Second Floor -Tub Access 24�10s3Pipe; Size & Anchors Date/initials ELECTRICAL (Permit) OK except #'s 22. Fixture & Transformer Clearance -Ins. Protection flec. Receptacles Spacing -Lights & Switches at Doors 2 . Size Boxes & No. of Conductors -Stapled I omex Install?A Close to Edge of Studs & C.J. 26. Equip. Groph made up w/Mach. Fastners-Bond 6W& 0 err' 2 Appliance Circuts in Kitchen & Conductor Size/GFI Subfeed Wire Size y/ ga. Cu or AI-A.C. Wire Size /$/ ga. /9 or Al 2<Range Circ. / / ga. Cu or 1 -Oven Circ. /La' ga.©or Al. Insulated Neutral MYes U No Service -Riser Conductors & Ground -Main Disconnect ,Equip. Clearances Panels -Motors -Mach. Equip. 6. Clothes Closet Light -Shower Light -Spa Light Lld Smoke Detector Date/Initials MECHANICAL (Permit) OK except #'s 34. AC. Ducts In lation & Support t Fan- ' 36. Condensate Drain & Overflow; Size & Grade 37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet 38. Attic Access & Platform if Furnance in Attic Ly Date/Initials FRAMING Plans OK except #'s 3 . Sils, Proper Material & Anchors 40./'Walls Studs -Nailing, Spacing & Bracing -Plates -Sound 4 . Bearing Walls over Girders & Floor Nailing 4 . Dratt Stop in Wells (rat proof) Fire Stops; Furred ngs-St ' s -Chases -Tub 9t71A,.4 Headers Beam 'na r� Date/Initials FRAMING (Continued) Hangers- st Caps -Anchors -Connectors Cing. Joist-Rftr. ties- Puri ln—roof Bra ruse hthng.-Ring. Fireplace Ties or Type A Flue -Fireplace Throat clearance O.'Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions !p'I�rll arage Fire Protection Framing �s J< Property Line Firewall & Openings , . Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits 59—Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection plywood on Roof Overhang -Attic Vents -Rafter Outriggers 55,Ading-Nailing Veneer 56c8TGcco Mesh -Drip Screed -Fd. Vents-UndeAlr. Access . Glazing Area -Glass Protection -Skylights -Plastic 5&.—Mar Walls; Nailing -Bolts gjg2LT�On-Wjafrs-CeifGgs 8 nfiltr on- Is-Wi ows Date/Initials FINAL Plans OK except #'s _ . Steps -Door & Sidelight Protection -Landings &. 'Smoke Detector VeTurnace; Vents -Clearance -Comb. Air-Connector- _kr'Garage; Above Floor -Ducts -Meth. Protection Bedroom Exiting G.F.I. & Bath Fixtures & Tub Access -Spa Elec. Trim & Subpanel; Breaker Sizes & Labels 67. Stairs & Rails . Fireplace or St . ; Clearances -Hearth 69r-Rec. Outlets at Wood Panel; Int. & Ext. 7 it.Fixt. & Appliance; Grnd: Air Gap -Cooking Clearance 71,!!T!c. Outlets & Receptacles at Kit. Counter 7g,,da—rage Fire Door, Swing -Landing -Closer 7 . Duct in Garage -Damper tVVFr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V. In Garage; Above Floor -Mach. Protection 7.9"P—lb., Elec. & Mach. Equip. Listed for Location Elec. Receptacles in Garage; (G.F.I.)-Romex Protection 7 nsulation-Foam-Looked in Attic ❑ Yes 71:�buard Rails & Deck Construction -Post Caps 7 . Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes Be Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑ Yes ❑ No 44—Stucco; Brown -Finish Of A.C. Unit; Disconnect, Electrical, Plumbing (33' Vents Above Roof; Plbg: Appliance -Fireplace: Clearance to Openings 1![I W ter Well; Disconnect, Electrical, Plumbing . Exterior Elec. Trim; G.F.I. Receptacle -Underground Ventilation Throughout House li7'. 'Glass Protection Corrections from Previous Inspections .j t)lq s iip -Meters Tagged; Gas -Electric GG' Ater & Sewer Connected -C/O to Grade -HDA oval Energy compliance Certificate- her Ce cater Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF D<;VFLOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive - Oroville,'Califo ria •95965 - Telephone (916) 538-7 41 �q_ O?EjRMIT No. 3� APPLICATION AND PERMIT �,� ASSESSOR PARCEL NUMBER 064-780-035 ZONING RT1 BUILDING PERMIT OWNER NRSXXXNRSX URSULA BASHAM TELEPHONE SQ, FT. OCC. BUILDING VALUATION 1784 R 96,336 OWNER'S MAILING ADDRESS 7320 QUILL DR., #37DOWNEY CA 90242 528 M 9,504 cDNMIKEsRUTLEDGE 872ETELEPHON2602 14p0 C 1,820 288 0 2,016 CONTRACTOR'S MAILING ADDRESS 6341 LUCKY JOHN RD. PARADISE CA 95969 Fireplace A 1,500 CONSTRUCTION LENDER UNKNOWN Total Valuation $ 111 176 Filing Fee $ 20.00 LENDER'S MAIL'NG ADDRESS Permit Fee $ 681.50 ARCHITECT OR ENGINEER LICENSE No. Plan Checking Fee $ 443.00 Energy Plan Checking Fee $ 23.00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRESS 14365 TRny WAY, MAGALIA PERMIT FEE $ 1,167.50 PLUMBING PERMIT Filing Fee 20.00 Each Trap 0 1 7.00 70.00 Solar or heat pump water heater 23.00 Water piping 15.00 1 5 -no LOT NO. SUBDIVISION'S NAME PARCEL MAP Each gas water heater or vent 15.00 15.00 USE OF STRUCTURE SF CR Duplex O Mobilehome ❑ Other SPECIFY Gas piping system 1 5 outlets 15.00 15,00 Building sewer 15.00 Mobile Home S G W @20.00 TYPE OF WORK NewR Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other ❑ Describe Work: 3 BEDROOM PERMIT FEE $ Contractor ELECTRICAL PERMIT Filing Fee 20.00 Main Service ( 600VORLESS ) 200A OR LESS 23.00 Main Service ( 200A TO t000A ) 46.00 NEW CONST. DWELLING OCCUP. OR ADONS. ( & ACC. BLDS. ) SO. 3.50 FT. NEW CONST. MULTI -OUTLET .NON-RESID. ( BRANCH CIRCUITS ) @7.50 CONTRACTORS LICENSE LAW( I declare under penalty of perjury (check one) O 1 am a licensed under provisions of Chapter 9, Division 3 of the Business and Professions Code and my license is in full force and effect. License No. TZ / S!/ Classification I�� i� � iL�i4 � ❑ I, as the owner, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. (Sec 7044) ❑ 1, as the owner, am exclusively contracting with licensed contractors. (Sec 7044) ❑ 1 am exempt under Sec. Business and Professions Code forthis reason POWER APPARATUS ) & SINGLE OUTLET CIR. Ex. Occup. ( OUTLET OR FIXTURES ) 20 BAL. @ (.50 Ex. Occup.FIXED APPLNS. OR ((RESID.) EA. ) OUTLETS 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 WORKER'S COMPENSATION INSURANCE 1 declare under penalty of perjury (check one): ❑ This permit is for $100.00 (valuation) or less. ❑ 1 have placed on file with the County of Butte Dept. of Development Services, Building Division a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -insure. I shall not employ any person in any manner so as to become subject to the Worker's Compensation laws of California. Notice to Applicant: If after making this statement, should you become subject to the Worker's Compensation provisions of the Labor Code, you must forthwith comply with such provisions or this permit will be revoked. PERMIT FEE $ 123.90 Contractor MECHANICAL PERMIT Filing Fee 20.00 Heating 15.00 Cooling L 25.00 Hood 6.50 6,50 Ventilation PERMIT FEE $ 71 -nn Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all Butte County Ordinances and California State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above mentioned property for inspection purposes. 1 also agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments, costs, and expenses which may in any way accrue against said County in conseque�thheof thispermit. r Date C� ; %y Signa ure of Applicant Owner Contr r ❑ Agent An OSHA permit is required for excavations over 5"0" deep and demolition or construction of structures over 3 stories in height. �� / Mobile Home Installation Fee $ Energy Inspection Fee $ 46.00 CONST V TOTAL FEES 1,558.40 HAZ• I D. FEES �" IMP I F10� ✓ cOF PARCEL PD '� H} �/ Issu This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indigatqd above for which fees have been paid. 3/� 9 Date / PERMIT EXPIRES ON qs Mate) Receipt No. 156170 546.00/056665&n`GOLDEN7� WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INS ECTOR R00 -APPLICANT COUNTY•00FTBU`('TE DEPARTMENT'6P'PUtLIIC WORKS 1469 Humboldt Road, CW@o, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538=7541 747 Elliott Road, Paradise, CA - (916) 872-63071 CORRECTION -NOTICE s o� � !' y OWNER � PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above ad ress and should be corrected. Please notify this office when correction of work is complet. If you have any questions pertaining to this matter, or need additional explanation, please c ntact this office immediately. Ss 11ATIoJ C 2 Fi A 1 „1e-f—S Date 9V%T Inspector A REV 11/91 k ' ._- 'ri�'tJFi`+"�+^t1�:ot-• ..tea -+.r,� � �- .--- -. COUNTY OF BUTTE DEPARTMENT" OF PUBLIC WORKS 1469 Humboldt Road, Chico, CA - (916) 891-2751 7 County Center Drive, Oroville, CA - (916) 538-7541 747 Elliott Road, Paradise, CA - (916) 872-6307 6�. L CORRECTION NOTICE T) s V1 V v- y3� OWNER PERMIT NO. A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, Please act this office immediately. A i n I/ -'r 11 A /j, i i -> l 1 A „ r -nN� A 4 C S/- t/ c rG N7-5 Date -) L Inspector REV 11/91 Description of Installation ROOF Thickness (inches) . CEILING B r-hd None _ ThcgrW Rcsiuzncc (R-Va1uc) BattorBLzn3vctTY9e FIBERGLASS Br=.dName ' CERTAINTEED Tbicicncss (inct•cS) /Q '173crrnaI Rcristarsca (R-VrrIcc) 'msc=diT7Pc INSULSAFE III BrandNsmc CERTAINTF.Fn Ccn=mcr:s minimum instuned waghtift lb Muumum thirk='t - #I MznufacturcesLuwiedweight persqu=foot toacheiveTh=m1Resist3nce(R-Value) 3(7, E�CiEAIOR WALL ' Muu31IETR P. • 3N6== (inches) RAISEDFLOOR Maw FIBERGLASS 7 duress (inches) i BrandN=P- CERT - Tacrursl Rcssartz (R-Valuc) BrandN=e CERTAINTEED Thenal Resiscz= (R -value) SLAB FLOOR 1►iirzul Brand Naris Ths) wld'h(inches) Thcrn al Rcs:umrcc (R -Your.) FOUNDATION WALL i+tatrti FIBERGi,ASS IIraadNamc CERT Thiclrncss (incrtcs) Thermal Rcsisunce (R -Value) Declaration I hcrrty anti fy th>t the above iruulstion was installed in the building at the above location in conformance with tlu euzrc m Building Energy Efficiency Sundanis for new tuidential buildings eonuincd in Califo-ml Administruivc Codc. Title 24 of the. Ccnu ona.c a a+IJcr lxwc Numlxr �i� (r+►curs vet Tek w Dne S4STA1 I N MAT 10N 272941 rIsco rtV. "; tn,a.) txoNwnDa Sjpurvs +red iuk Due Installation Certificate: Residential r..- CF -6R BUILDING OWNER: BUILDING PER14IT #: BUILDING LOCATION: An installation certificate is required to be posted at the building site prior to the issuance of the occupancy permit. This form may be used to most these requirements. All appliance categories listed below are the actual equipment installed. Note that the efficiency and type of the appliance installed must be equivalent or better than the appliance specified on the Certificate of Compliance (CF -1R). This certificate (or its equivalent) shall be prepared and signed by the person(s) assuming overall responsibility for the appliance installation. I, the undersigned, verify that the equipment listed in the category above my signature is the actual equipment installed and that the equipment meets or exceeds the requirements of the Appliance Efficiency Standards. In addition, I have verified that the equipment is equivalent to or more efficient than the equipment specified on the Certificate of Compliance submitted to demonstrate compliance with the Energy Efficiency Standards for residential buildings. HVAC SYSTEMS Note: Hydronic boiler information is entered here. Other hydronic.or combined hydronic equipment is listed under Water Heating Systems. Heating Equip. CEC Certified Actual Distribution Duct or Heating Load Heating Type (furnace, Manuf. Make & Efficiency Type and Piping Before Over- Equipment heat pump, etc) Model Number (AFUE, etc) Location R -Value Sizing (Btuh) Capacity (Btuh) CEC Cartff led Cooling Equip. Compressor Unit Actual Distribution Duct or _ Type (air cond., Manuf. Make & Efficiency Type and Piping heat pump, etc) Model Number (SEER) Location R -Value The building design heat loss and design heat gain rate have been determined using a method specified in Section 150(h) of the Energy Efficiency Standards, and are two of the criteria used for equipment sizing and selection. Signature Date HVAC Subontractor (Co. Name) or General Contractor or Owner WATER HEATING SYSTEMS Energy External Water Heating CEC Cartff led Rated' Tank Factor or Tank System Type Manuf. Make & Input (kW Capacity Recovery Standby' Insulation (storage gas etc) Model Number or Stuh) (gallons) Efflclency Loss (%) R -Value 1. For small gas storage (rated inputs 75,000 8twhr), electric resistance and heat pump water heaters, list Energy Factor. For large gas storage water heaters (ratea input >75,000 8twhr), list Rated Input, Recovery Efficiency and Standby Loss. For Instantaneous gas water heaters. list Rated Input and Recovery Efficiency. For Instantaneous electric water heaters, list Rated Input. FAUCETS & SHOWER HEADS All faucets and showerheads installed are listed in the Commission's Directory of Certified Faucets and Showerheads, pursuant to Title 24, Part 6, Subchapter 2. Section 111. Signature Date Plumoing Subcontractor (Co. Name) or General Contractor or Owner `191IS CERTIFICA'F!, MUST BE PROVIDED TO THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL Air'D A COPY SHALL BE POSTED WITHIN THE BUILDING. JANUARY 1993 , . APR 19 01 08:36 PGL BLDGPRODSAC_, f;V , �•di ♦. f.-.. ; P. 2/3 t j e o s i. I MAIO m� PA.K.FrI1161 :. C. Certificate of Conformance Certificate N? 9248 -91 • THE UNDERSIGNED MANUFACTURER HEREBY CERTIFIES that the structural wood products identified below and marked with a collective mark of American Wood Systems (AWS) were man- " ufactured in accordance with the specifications indicated below. RC ANSI Standard A190.1-1983, for Structural Glued Laminated Timber 0 D Job Name PGL BLDG PRODUCTS Job Location SACRAMENTO, CA Cuatomer's C7rder No. 01-29972 Date 2-25-93 M1gr'9 Order No. 7495=C Signature Company ROS80RO LUMBER CO. END JOINTS Address Title QUALITY CONTROL SPRINGFIELD, OREGON Dat® 3-2-93 IT IS HEREBY CERTIFIED that the structuralglued laminated timber production of the above-named manufacturer which carries a collective mark of American Wood Systems (AWS) is subject to regular audit by American Wood Systems, such audit consisting of the inspection with reasonable frequency of the manufacturing process, with adequate sampling to verify the quality of glulatn construction and the adequacy of glue bond. T%ft'�` .Ft n•e_ ��QOR�•• b, SEAL '• Michael Ft. O'Halloran Executive, Vice President :,v • �e AMERICAN WOOD SYSTEMS A RELATED CORPORATION OF AMERICAN PLYWOOD ASSOCIATION ".0* j� RQP?. • �Acgar ROSBORO LUMBER COMPANY P.O. Box 20 9- Springfield, OR 97477 PHON5: (503) 748 8.411 • FAX: (503) 726-8919 0 16 '13;.Jul (:!d'! eLA I :Raz 99F.x) ("I I,.;) 'c':1 9 4.il"Jip V:LaL TF:UCK r( ORD UP GPC ST MARK I OTY OTY WIDTH DEPTH FEET IN FRACT Cll� GR COMA. V 5-310 12, .12 03-1/8 1 10-1/2 60 02 'g D V4 2400F 5-312 12 12 03-1181 12 60 02 D V4 2400E S-313 4 4 03-1/8 1 is -M 60.02 i D V4 2400F $-512 12 4 03-1/8 X 12 60 021 0 V4 2400F 05-1/8 1 13-1/2 60 02' 1 D V4 240OF 8-612 .3 3 06-3/4 X 12 ..60 02 0 V4 2400F 3 06-3/4 x 15. 60 02 ♦ 1 D V4 2400F 5-616H S 3 06-3/4 1 16-112 50 00 1 D V4 2400F S-621 1 1 -06-3/4 1-21'44 '2460 D X - 512R: a 8 05-1/9 .1 1.2 44 02 1 0 V4 2400F -4p 6Z -11NX. TOTAL SHIPPED FOOTAGE 1 pwm mww 60 howd dooftm with WOW &aW* bUI& Al*wl" NIN 0 XVY on OU— Of V%ft MY CUSTOMER'S ORDER IS SUBJE9T .PW Pak dug wwjo vm be mawd a wvw awo of 1%% ttlofdh (te96 per annum)- TO ALL OF THE TERMS AND C.6ffw awoo 1. wit-hily Room number 0&4irw lei in o; -W- W ---.d In coorAction CONDITIONS STATED HEREIN. With UM C0110060001 WCOWN" d- 11~4K bld~ *N01=60 2" oftnftrs rasa tneumed -'. -n' -:, at a*-tlw %4 NW an ww ww. T. 5, PA Mo.ftepromft Oft wdw w* U00-0*6 la dOt)NTY OF BUTTE - DEPARTMENT OF DEOELOPM ENT SERVICES -BUILDING DIVISION 7 COUNTYCENTER DRIVE - OROVILLE, CALIFORNIA 95965 - TELEPHONE (916) 538-7541 /I've PERMIT APPLICATION DATASHEET OWNER I^S 1 a S L� ~ A. P. o. 4,41- % D Proposed Building Use We c - Building Inspector Date At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance: DATE RECEIVED BY 1, All items have been submitted......................................... 2. Plot plans, 3/4 sets, signed by preparer of plans . .......................... 3. Complete plans, 3/4 sets, signed by preparer of plans . ...................... 4. Engineered plans and calcs, 3/4 sets, with wet signature on plans . ............. 5. Hazardous Material Form . ........................ 1 6. Energy Design Compliance and supporting documentation . .................. 7. Statement of Intent for Non -Heated and A/C Buildings ...................... l 8. Engineered truss details and layout in duplicate (required prior to plan check). ... -&37q4fr 9. Mobilehome d a and mar�u�acturer's installation instructions, 2 sets. ........... 10. Fees of $ /04 4 C/ ........................................ . 11. Impact fees as shown on attached schedule. ... ' * * * ' * ' ' .... ... *-- 12. . 12. California Department of Forestry plan approval es. ��..... q � 13. Flood elevation letter (100 year floo by Califor ngineer. 14. Sanitation and plot plan approval A 9' CI Health Department. .......... (? 15. City of Chico plumbing permit . ......................................... 16. Plot plan and business license approval from City of Biggs/Gridley. ............ . 17. Planning approval for (A) Use: (B) Parking: ' . ....... . 18. Contact Land Development about (A) Improvements (B) Drainage. . JZ'19. Driveway permit (construction approval required prior to occupancy). .. to Building Ins reque M. Pre -inspection for required. .. � Buflaing �nspedor 21. Contractor's license information. (No., Name Style, Classification) . .............. 22. Certificate of Workmans Compensation Insurance . .......................... 23. Owner -Builder Verification (Given to owner , Mail to owner .. . 24. Recorded copy of Agricultural Acknowledgement Statement . .................. 25. Letter of signature authorization . ........................................ 26. Copy of recorded deed of parcel creation and 60 right of way to a public road. ..... 27. Letter of intent on building use . ......................................... 28• Mobilehome utility clearance . .......................................... 29. Documentation of legal access . ..................... ; .................. ° 30. Documentation of 50% subdivision developed or (A) Road improvements completed and (B) Parcel meets zoning area and frontage requirements . ............... 31. Existing violations/expired permits . ...................................... Plan checklist. ......................................... 33. �'�A� 4 44 .34. W en you issue th rmit, rocess as follows: Mail to owner. Mail to contractor. Telephone - and hold for pickup at (0 office. Deliver with inspector. Other Parcel Creation Acreage Applica " Date"�o� �T fr Copy of Haz-Mat form sent Health Dept. Fire Dept. Air Pollution Date Copy of plans sent Health Dept. Fire Dept. Other Date By The following data must be submitted prior to per it i uance' Cir le DeW ItEprpot ch above). 1. Index permit for above items No. ' 2. Additional items required: Cont or, designer, owner, was advised of above required data by _ phone _ mail Counter by QVzBate 4 Contractor, designer, owner, was advised of above required data bp hone _ mail Counter by _ Date Plans checked by DatePfa.nsf approved by Date 9 n Yp. Sets of plans on hold in File cabinet AP folder 3 �/ Copy - Department of Public Works How Him hlu{ched sent to II:I). TO: Building Departnjent FROM: Environmental health SUBJECT: Sanitation Clearance 79 " 7�' "'j Owner / . Locati � AN Plan Approved for. Sewage Disposal ✓ Water SLI)ply: II'ublic /l Private Well Clearance for bedroom I�t 4i e home.,0thcr c,fir,�.�i Q K /� S'Gr���.5y► . _ .�j — o -1-- A 0 - -. 0, Hold final for: Final clearance O.K. for: NOTE: Environmen 1 8/92 Ith Sndelalist aA Jk 0 '--1-- Date I COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE CA 95965 - TELEPHONE (9.16) 538-7541 OWNER liICA�Ot Srl Q 1 PROPOSED BUILDING USE C%-- DATE REC. # _ DATE REC 1. SCHOOL DISTRICT FEES L^ (paid at District Office) ......................... 2. SHERIFF FEES (paid at Building Department) Residential...... f x unit amt. Commercial (sgft) x I _$ sq.ft. amt. 3. URBAN AREA FEES (paid at Building Department) Residential (per unit) x -$ # units amt. Commercial (per sq.ft) x =$ sq.ft. amt. .4. RECREATION DISTRICT FEES (paid at District Office) ......................... 5. DRAINAGE DISTRICT FEES (Contact Land Development Division) .............. V 6. SRA FIRE INSPECTION AND PLAN CHECK = 9.00 ..... ,r 5-� % 2 (paid at Building Department) 7 7. OTHER 8. OTHER At time of permit application, I was advised the above fees are required to be.paid prior to issuance of the permit. APPLICANT DATE F :r,}a.:ir`"dr�' fiw..,^X�y;il;�h;�.:�:`.S�'+'tk.,.i:i.y�j��..«r'r`„yr'�%`�r�+ry'�,"'."':^yr^`r`�a ^xr%y...^t.•Yia„-'ti"^"�^yY� :'Sw BUTTE COUNTY SCHOOLS I ACfFEE CERTIFICATION FORM (One Form Per Building) School District (” U_�_) D Building Department No. XP. Number (u 18 +i5 Jurisdiction 0 City EX County Property Owner tE Property Location/Address E,5+- Subdivison 1 �� �- Lot No. 132— UJW z Residential Development ti Sq. Footage No. of Living MHI,, Addition (Group R) Units . Commercial/Industrial Building Department Representative 0 Sq. Footage New Addition (Including Exterior Roofed Areas) (Floor Plans reviewed by School District Personnel) Date District Identification No. GO 134 ad_School District certifies that Cl, (Applicant) (Street Address)/ (Phone Number) (City) (State) (Zip Code) t" has complied with the requirements of Resolution -No. by payment of $ representing �?�'U square feet. ` School District Representative Date Paid by Check Number Remarks:. Bank Number % bu - f t Paid by Cash If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeformmkl (4/92) r "- 94=012499 94-012499 94-012499 94-0124991 Rec Fee i 6. 00 1 Cash 6.00 Recorded Official Records I County of I -Y. Butte Candace J. Grubbs I =i Recorder I :. 12:22pm.21-Mar-94 1 PUBL XX 1 Petdrn to: AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT Building Division FOR RESIDENTIAL DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. COMPARED WITH r11911�rA9gr The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or R t� 11994 discomfort arising from the use of agricultural chemicals, �G, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust,smoke, noise, and odor. Butte County has established agricultural zones which have as a priority use for productive agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in. the County of Butte, State of California, described as follows: IAT 32, AS. SHOWN ON THAT CERTAIN MAP ENTITLED. "TROY E.TATLs UNIT No' 2"1 WHICH MAP WAS RECOROZO IN THE OFFICE OF TH8 RECORDER OF TMME COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 7, 1991, IN DOOX 122 OF MAPS, AT pAGZ(S) 80, el AND 82. FLOWAGE RIGHTS FOR DRAINAGE OF STORM HATER ACROSS roT 70 FROM FLOWAGE RIGHTS LINK TO MSDoLn CUTTS.CREEK, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "TROY ESTATES UNIT NO. 2", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 7, 1991, IN COOK 122 OF MAPS, AT PACR(S) 00, al AND d2. AN CASL'MCNT FOR CREEK BETWEEN THE HICHWATER LINES, AS SHOWN ON LOT 20 OF THAT CERTAIN MAP ENTITLED, •*TROY ESTATES UNIT NO. 20, WHICH MAP WAS RECORDED IN THE OFFICE OF T11R RECOROCR Or THE COUNTY OF DU'rTP, OTATZ OF C►LIPORNIA, OH NOVEMBER 7, 1991, IN BOOK 122 OF MAPS, AT PACES) 80, 81 AND $2. Date: 3/15/94 PROPERTY OWNERS: State of California County of Butte On 3/15/94 before me, Ellen E Hunt, Notary Public personally appeared Ursula E Basham personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose names) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument. WITNESS my d and offi seal. M 4 NOTAPY Signature Seal: @ ? T PRyCammisebnv Cn ny Eq*n July 20.1898 i�mt��®®Olct�MA®�0o6181'B®®i�M�1i'� A.P. At /� RESIDENTIAL.PLAN CHECKING GUIDE 8/91 (S.F., DUPLE)( & MISC. ONLY) Bldg. Permit # r�a OWNER 45Q44a9-a9y A . P. # GENERAL -- Plan Checker 1 Zoning requirements: (sideyards and number of permitted living units). Valuation. �! Plans signed by designer. *--'Proper description of work on application. '5"Existing violations on property. Items on data sheet. (W.C., fees, Health, Developer Fees, License law,'etc). -recorded notice of violation. PLOT PLAN Complete parcel size and dimensions. Setbacks, sideyards, easements, etc. ther buildings or structures. -rading, fills, drainage. Flood hazard. Special conditions on creation map, ustible, and foundations). FAU & FAS road setback. (noise, CDF, fire sprinklers, non -comb - Building or utilities across lot lines (Record form). FU'0P PT.AN Complete to scale plan with dimensions. , Required windows for light and ventilation (Sec. 1205). Required windows for second exit (Sec. 1204). Skylights (Chapter 34 & Sec. 5207). Human impact glass (Sec. 5406). Required room sizes, ceiling heights (Sec. 1207). GFCIs in baths, garage, kitchen, and exterior outlets (Article Light fixtures, switches, receptacles, and exterior receptacles .tenance of mechanical equipment. Locations of water heater, heating and cooling equipment, other Pr gas equipment. Garage firewall, door size, and closer (Sec. 503(d)(3)). 1 — 3'0" exterior exit door (sec. 3304 (f). fireplace and wood stove location, alcoves, and clearance. Smoke detectors (Sec. 1210). Plumbing fixtures, water closet clearances and shower size. STRUCTURAL DETAILS 210-8). for main— electrical Standard bracing or engineered design (Table 25V) Unusual shape, size, or split level house requiring lateral design. Clerestory requiring balloon framing and/or engineering. Three story building requiring engineered calculations and plans. Foundation plan complete enough to construct building. Floor construction details complete enough to construct building. Elevations and wall construction details c.omplete enough to construct Roof construction details complete enough to construct building. Fireplace construction details and calcs if necessary. Rafter ties or bearing ridge beam. Garage door or porch header sizes. Stud heights. Adobe soils — special foundation design. Retaining walls requiring design. Special Inspection required. building 8/91 RESIDENTIAL PLAN CHECKING GUIDE MISCELLANEOUS ITEMS TO LOOK OUT FOR Stairway details: landings, rise and run, head clearance, handrails (Sec. 3306). Guardrail details (Sec. 1711 & 3306(j). Brick or stone veneer (Chapter 30). Exterior plaster - weep screeds (Sec. 4706). Proper roof pitch for roof convering (Chapter 32). woof covering type - (fire hazard). /Foam insulation - protection. / 36" halls and stairways. Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts, etc. 9—TW exits on three-story dwellings (sec. 3303 & see Mezannines - 1716). i�Attic access and ventilation (Sec. 3205). nderfloor access and ventilation (Sec. 2516). Combustion air for fuel,burning appliances - L.P.G. requirements. oise requirements on duplexes. n -Energy design. ashing at all exterior openings. P.�TCIDF responsible area requirements. COMPUTER METHOD SUMMARY Use Standard Proposed Page 1 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 Project Address........ TROY WAY Heating.......... --------------------- ' MAGALIA, CA 95954 . | | Documentation Author... ROBERT A. MANGRUM 1 Building Permit.# 1 Company................ PARADISE MECHANICAL | | Telephone.............. ' 916-877-8881 ' � Plan Check / Date� Compliance Method...... MICROPAS4 by Enercomp, Inc. | | | Field Check/ Date | Climate Zone........... 11 , ------------------------- -------------------- 1 | . MICROPAS4 v4.02 'File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R | ` | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE,ENHANCED CASE� ' | _______________________________________________________________________________ � ' � = MICROPAS4 ENERGY USE SUMMARY = = ^ ____________________________ = = ` = = Energy Use Standard Proposed Compliance = (kBtu/sf-yr) =----------------------- __________ Design Design __________ Margin = __________ = = Space Heating.......... 12.50 12.57 -0.07 = = Space Cooling.......... 14.21 11.96 2.25 = = Water Heating.......... 12.70 10.34 2.36 = = = Total ________ 39.41 34.87 ________ = 4.54 = = *** ================================================================= Building complies ' with Computer ^ = Performance *** = ' GENERAL INFORMATION -------------------- Conditioned __________________ Conditioned Floor Area..... Building Type.............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... . Number of Building Stories. . Weather Data Type........., Floor Construction Type.... Number of Building Zones... Conditioned Volume......... Footprint Area............. Ground Floor Area.......... Slab -On -Grade Area......... Glazing Percentage......... Average Ceiling Height..... 1784 sf Single Family Detached New Front Facing 100 deg (E) 1 1 ReducedYear Raised Floor (Package E) 1 15112 cf 1784 sf 1784 0 sf C h6sov., 001 14:5 % 91 BUTTS ^ COMPUTER METHOD SUMMARY Page 2 C -X =============================================================================== Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 | MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R | | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE ENHANCED CASE | _______________________________________________________________________________ Zone Type ---------- HOUSE Residence BUILDING ZONE INFORMATION ---------------------------- Floor ________________________Floor ' # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area (sf) (cf) Units itioned Type (ft) (sf) ____ _________ _________ _____ _______ ____________ ______ ------------ 1784 ________ 1784 15112 1.00 Yes Setback 2.0 n/a FENESTRATION SURFACES # of OPAQUE ______________Area SURFACES SC Area U- ----------------- Insul Act Area Solar Form 3 Location/ Surface ______________ (sf) ______ value _____ R-val Azm Tilt Gains Reference Comments HOUSE Type Type _____ ___ ____ _____ ____________ ----------------- _______________HOUSE 1 Wall 201 0.088 R-13 100 90 Yes W.13.2X4.16 ____ 2 Wall 17 0.088 R-13 145 90 Yes W.13.2X4.16 90 3 Wall 17 0.088 R-13 55 90 Yes W.13.2X4.16 0.650 4 Wall 357 0.088 R-13 190 90 Yes W.13.2X4.16 Metal 5 Wall 269 0.088 R-13 280 90 Yes W.13.2X4.16 15.0 6 Wall 212 0.088 R-13 10 90 Yes W.13.2X4.16 5 7 Roof 48 0.035 R-30 10 90 Yes R.30.2X12.16 ATTIC WALL 8 Wall 118 0.088 R-13 10 90 No W.13.2X4.16 90 9 Wall 48 0.088 R-13 100 90 No W.13.2X4.16 0.650 10 Roof 1384 0.031 R-30 0 0 Yes R.30.2X4.24 Attic 11 Roof 413 0.031 R-30 100 24 Yes R.30.2X4.24 Attic ' 12 Door 20 0.330 R-0 100 90 Yes None 10 13 Door 18 0.330 R-0 10 90 No None 0.78 14 Floor 1784 0.037 R-19 0 0 No FC.19.2X8.16 RAISED FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Descriptin ___________ HOUSE _____ ____ _________ ______ _____ ' ___ ___ ____ ____ ------------------ ______________HOUSE 1 Window 20.0 2 Metal Slider 0.650 100 90 0.88 0.78 None 2 Window 20.0 2 Metal Slider 0.650 100 90 0.88 0.78 None 3 Window 15.0 2 Metal Slider 0.650 145 90 0.88 0.78 None 4 Window 15.0 2 Metal Slider 0.650 100 90 0.88 0.78 None 5 Window 15.0 2 Metal Slider 0.650 55 90 0.88 0.78 None 6 Window 21.0 2 Metal Slider 0.650 190 90 0.88 0.78 None 7 Window 30.0 2 Metal Slider 0.650 190 90 0.88 0.78 None 8 Window 53.0 2 Metal Slider 0.650 280 90 0.88 0.78 None 9 Window 34.0 2 Metal Slider 0.650 280 90 0.88 0.78 None 10 Window 20.0 2 Metal Slider 0,650 280 90 0.88 0.78 None 11 Window 12.0 2 Metal Slider 0.650 10 90 0.88 0.78 None 12 Skylight 4.0 2 Metal Fixed 0.650 100 0 0.88 1.00 None I COMPUTER METHOD SUMMARY Page 3 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 1 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R | | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE ENHANCED CASE | _______________________________________________________________________________ OVERHANGS AND SIDE FINS [HERMAL MASS ---Window-- Thick ------Overhang----- Conduct- ---Left Fin--- ---Right Fin -- (sf) ______ Area Cap _____ ivity ________ R -value ________ Location/Comments __________________________ Left Rght Surface InteriorVert (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght ___________ HOUSE _____ _____ _____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ------- ___HOUSE 1 Window 20.0 4.0 5.0 7.5 0.0 n/a n/a n/a n/a n/a n/a A/a n/a 2 Window 20.0 4.0 5.0 7.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 53.0 6.6 8.0 2.5 0.0 n/a n/a n/a n/a n/a n/a 'n/a n/a 9 Window 34.0 4.0 8.0 2.5 0.0 n/a n/a n/a n/a n/a n/a M/a n/a 10 Window 20.0 4.0 5.0 2.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 12.0 4.0 3.0 1.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a [HERMAL MASS System Type ---------------- HOUSE Furnace ACPackage HVAC SYSTEMS -------------- Minimum ___________Minimum Duct Duct Duct Efficiency Location R -value Efficiency ____________ _____________ _______ ----------- 0.785 _________ 0.785 AFUE Crawlspace 12.00 SEER Crawlspace WATER HEATING SYSTEMS _____________________ Number in Tank Type Heater Type Distribution Type System ____________ ___________ ___________________ ______ 1 Storage Gas PipeInsulation 1 SPECIAL FEATURES/REMARKS --------------------------- WATER _______________________WATER HEATER: AO SMITH FGR -50-0.60 OR EQUIV. 1 CARRIER 48TLX042 AFUE 78.5 SEER 12.0 R-4.2 0.830 R-4.2 0.860 Tank External Energy Size Insulation Factor (gal) R -value ________ ______ ------------ 0.60 _________0.60 50 R-12 Area Thick Heat Conduct- Surface Mass Type _______________ (sf) ______ (in) _____ Cap _____ ivity ________ R -value ________ Location/Comments __________________________ HOUSE ' 1 InteriorVert 50 4.0 21.0 0.59 R-0.0 STOVE HEARTH 2 InteriorVert 17 4.0 21.0 0.59 R-0.0 STOVE HEARTH 3 InteriorVert 138 1.0 24.0 0.67 R-0.0 BATHS 4 InteriorHorz 71 1.0 24.0 0.67 R-0.0 BATHS/KITCHEN 5 InteriorHorz 20 1.5 24.0 0.67 R-0.0 ENTRY System Type ---------------- HOUSE Furnace ACPackage HVAC SYSTEMS -------------- Minimum ___________Minimum Duct Duct Duct Efficiency Location R -value Efficiency ____________ _____________ _______ ----------- 0.785 _________ 0.785 AFUE Crawlspace 12.00 SEER Crawlspace WATER HEATING SYSTEMS _____________________ Number in Tank Type Heater Type Distribution Type System ____________ ___________ ___________________ ______ 1 Storage Gas PipeInsulation 1 SPECIAL FEATURES/REMARKS --------------------------- WATER _______________________WATER HEATER: AO SMITH FGR -50-0.60 OR EQUIV. 1 CARRIER 48TLX042 AFUE 78.5 SEER 12.0 R-4.2 0.830 R-4.2 0.860 Tank External Energy Size Insulation Factor (gal) R -value ________ ______ ------------ 0.60 _________0.60 50 R-12 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -11--..: =============================================================================== Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 Project Address........ TROY WAY -------------________ MAGALIA" CA 95954 | � Documentation Author... ROBERT A. MANGRUM | Build�ng Permit # | Company................ PARADISE MECHANICAL Telephone.............. 916-877-8881 / . Compliance Method...... MICROPAS4 by Enercomp, Inc. | --------eck/ Date � Climate Zone........... 11 --------------_______ =============================================================================== / MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R | | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE ENHANCED CASE | GENERAL INFORMATION Conditioned Floor Area..... 1784 sf Building Type.............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 100 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Raised Floor (Package E) FENESTRATION BUILDING SHELL INSULATION Component Insulation -------------------------- ________________________Component Assembly Type _____________ R -value __________ U -Value Location/Comments Wall R-13 ________ 0.088 ________________________________________ Roof R-30 0.035 ATTIC WALL Roof R-30 0.031 Attic Door R-0 0.330 Fins Floor R-19 0.037 RAISED FENESTRATION # of Interior Over - Area U- Pan- Shading/ Exterior hang/ Framing Orientation ___________________ (sf) _____ Value es Description Shading Fins Type Window Front (E) 20.0 _____ 0.650 ____ 2 _______________ None ___________ None ____ Yes ------------ ________Window Metal Window Front (E) 20.0 0.650 2 None None Yes Metal Window Front (SE) 15.0 0.650 2 None None None Metal Window Front (E) 15.0 0.650 2 None None None Metal Window Right (NE) 15.0 0.650 2 None None None Metal Window Left (S) 21.0 0.650 2 None None None Metal Window Left (S) 30.0 0.650 2 None None None Metal Window Back (W) 53.0 0.650 2 None None Yes Metal Window Back (W) 34.0 0.650 2 None None Yes Metal Window Back (W) 20.0 0.650 2 None None Yes Metal Window Right (N) 12.0 0.650 2 None None Yes Metal Skylight Horz 4.0 0.650 2 None None None Metal ^ CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -11;. =============================================================================== Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 =============================================================================== | MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -11;.: | | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE ENHANCED CASE | _______________________________________________________________________________ Type Exposed InteriorVert Yes InteriorVert Yes InteriorVert Yes InteriorHorz Yes InteriorHorz Yes THERMAL MASS ------------- Area ___________Area Thickness (sf) ______ (in) Location/Comments 50 _________ 4.0 ------------ ____________ STOVE HEARTH ` 17 4.0 STOVE HEARTH 138 1.0 BATHS 71 1.0 BATHS/KITCHEN 20 1.5 ENTRY HVAC SYSTEMS WATER HEATING SYSTEMS Number Minimum Duct Duct Thermostat Equipment Type _______________ Efficiency ____________ Location R -value Type Furnace 0.785 AFUE ------------- Crawlspace _______ R-4.2 ------------- ___________Furnace Setback ACPackage 12.00 SEER Crawlspace R-4.2 Setback WATER HEATING SYSTEMS Number Tank External in Energy Size Insulation Tank Type Heater Type Distribution Type System ____________ ___________ ___________________ ______ Factor (gal) R -value StorageGas PipeInsulation 1 ________ 0.60 EF ______ 50 ------------- _________Storage R-12 SPECIAL FEATURES/REMARKS ------ __________________ WATER HEATER: AO SMITH FSR-50-0.60OR EQUIV. 1 CARRIER 48TLX042 AFUE 78.5 SEER 12.0 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R =============================================================================== Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 =============================================================================== | MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R | | User#-MP1342 User -PARADISE MECHANICAL Run-RUTLEDGE ENHANCED CASE | COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that, is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER DOCUMENTATION AUTHOR Name...., MIKE RUTLEDGE Name.... ROBERT A. MANGRUM Company. PARADISE CONST. Company. PARADISE MECHANICAL* Address. Address. 5796 CLARK RD! SUITE 16 PARADISE, CA 95969 Phone... Phone.'. 916-877-8881 License. y Signed.. Signed..` (date) ' (date) ENFORCEMENT AGENCY ' Name.... Title... Agency.. Phone... Signed.. HVAC SIZING =============================================================================== Heating Cooling Page 1 HVAC Project Title.......... RUTLEDGE RESIDENCE Date........ 02/23/94 Glazing Conduction............... Project Address........ TROY WAY Glazing Solar.................... --------------------- 7380 Infiltration..................... MAGALIA, CA 95954 Internal Gain...,................ n/a Documentation Author... ROBERT A. MANGRUM | Building Permit # � Company................ PARADISE MECHANICAL � | Telephone.............. 916-877-8881 | Plan Check / Date | Compliance Method...... MICROPAS4 by Enercomp, Inc. | Field Check/ | Date | Climate Zone........... 11 -------------------- ------------------------- 1 | MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -HVAC SIZING | | User#-MP1342 User -PARADISE _______________________________________________________________________________ MECHANICAL Run-RUTLEDGE ENHANCED CASE | GENERAL INFORMATION ___________________ Floor Area................. 1784 sf Volume..................... 15112 cf Front Orientation.......... Front Facing 100 deg (E) Sizing Location............ PARADISE Latitude................... 39.8 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 99 F Summer Inside Design....... 78 F Summer Range............... 34 F Interior Shading Used...... Yes Exterior Shading Used....." Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 HEATING AND COOLING LOAD SUMMARY Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Heating Cooling Description (Btuh) (Btuh) _________________________________ ___________ OpaqueConduction and Solar...... 9816 -------------- __________Opaque 4503 Glazing Conduction............... 6734 3535 Glazing Solar.................... n/a 7380 Infiltration..................... 8596 2593 Internal Gain...,................ n/a 2100 Ducts............................ 2515 1006 Sensible Load.................... 27661 21117 Latent Load...................... n/a 6335 Minimum Totdl Load ___________ 27661 __________ _ 27453 Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. ARI* capacities COOLING CAPACITIES AND EFFICIENCIES Carrier. UNIT 48 NOMINAL TONS STANDARD CFM NET COOLINGt SEERt SOUND RATINGS" (Btuh) (Btuh) CAPACITIES (Bels) TLX024 THX024 2 800 22,600 . 12.0 7.6 TLX030 45-75 74.4 TMX030 21/2 1100 29,600 12.0 7.6 THX030 30-60 _ 74.2 74.2 TLX036 45-75 75.2 TMX036 3 1300 35,600 12.0 7.8 TEX036 45-75 75.2 TLX_042_ 96,000 75,000 40-70 . 74.4 TMX042 31/2 1400 41,00012.0 �r i 8.0 TEX042 LEGEND Bels — Sound Levels (1 bel = 10 decibels) SEER — Seasonal Energy Efficiency Ratio 'Air -Conditioning & Refrigeration Institute. tRated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standard 210/240-89. "Rated in accordance with ARI 270-84. NOTES: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80 F db, 67 F wb indoor entering -air temperature and 95 F db outdoor entering -air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information avail- able from your retailer. HEATING CAPACITIES AND EFFICIENCIES UNIT 48 HEATING INPUT OUTPUT CAPACITY TEMPERATURE AFUE (%) CSE (%) (Btuh) (Btuh) RISE RANGE (°F) TLX024 TLX030 40,000 31,000 30-60 t 78.5 72.8 THX024 45-75 74.4 TMX030 T.LX036 60,000 46,000 45-75 45-75 78.5' ' 74.4 t— i TLX042 � 30-60 _ 74.2 74.2 `THX030 45-75 75.2 TMX036 80,000 62,000 45-75 78.5 75.2 TMX042 45-75 75.2 TEX036 TEX042 96,000 75,000 40-70 78.5 74.4 LEGEND 10TIppA( AFUE — Annual Fuel Utilization Efficiency �.'`�' �� off CSE — California Seasonal Efficiency = ►D,® NOTES: g ORS 1. Maximum NOx levels are 40 nanogramsfjoule. �'� cMW ✓� A �� 2. Before purchasing this appliance, read important energy cost and efficiency iniorma- � �ERiCIAPPAOVID tion available from your retailer. IF1 3 Return to: AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT 94 _ 12499 2 4 9 9 Building Division FOR RESIDENTIAL DEVELOPMENT J Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. - - ------- - -- -- - -- -- - - - -- The property described herein is adjacent to land or included , 94-0124991 Rec Fee 6.00 within an area zoned for agricultural purposes, and residents I Cash 6.00 of this property may be subject to inconveniences or Recorded I discomfort arising from the use of agricultural chemicals, Official Records I including, but not limited to herbicides, pesticides, and County of I fertilizers; and from the pursuit of agricultural operations Butte 1 including, but not limited to cultivation, plowing, spraying, Candace J. Grubbs I pruning, and harvesting which occasionally generate Recorder I dust, smoke, noise, and odor. Butte County has established 12:2 2 p m 21 -Mar -94 I P U B L XX 1 agricultural zones which have as a priority use for productive agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. ' All that real property situate in the County of Butte, State of California, described as follows: PARCEL 1: IAT 32, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "TROY -ESTATES UNIT NO. 2", WHICH MAP WAS RECORDED IN THE'OFFICE'OF THE RECORDER OF THE COUNTY OF BUTTE, STATE OF CALIFORNIA,.ON NOVEMBER,7, 1991,.IN BOOK 122 OF MAPS, AT PAGE(S) 80, 81 AND 82. PARCEL II: i FLOWAGE RIGHTS FOR DRAINAGE OF STORM WATER .ACROSS IAT 20 FROM FLOWAGE RIGHTS LINE TO MIDDLE BUTTE. CREEK,' AS SHOWN ON: THAT CERTAIN MAP ENTITLED, "TROY ESTATES ,UNIT;NO. 2", 'WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF. THE' COUNTY OF BUTTE, STATE OF CALIFORNIA, ON NOVEMBER 7, 1991, IN BOOK 122 OF,MAPS, AT PAGE(S) 80, 81 AND.82.. - PARCEL III: AN EASEMENT FOR CREEK BETWEEN THE HIGHWATER LINES, AS SHOWN ON IAT 20 OF THAT CERTAIN MAP ENTITLED, "TROY ESTATES 'UNIT NO. 2", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BUTTE, STATF. OF CALIFORNIA, ON NOVEMBER 7, 1991, IN BOOK 122 OF MAPS, AT PAGE(S) 00, 81 AND'02'. -` Date: 3/15/94 PROPERTY OWNERS: n State of California County of Butte On 3/15/94 before me, Ellen E Hunt, Notary Public personally appeared Ursula E Basham personally known to me (or proved to me on the basis of satisfactory evidence) to be the person(s) whose name(s) is/are subscribed to the within instrument and acknowledged to me that he/she/they executed the same in his/her/their authorized capacity(ies), and that by his/her/their signature(s) on the instrument, the person(s), or the entity upon behalf of which the person(s) acted, executed the instrument.oaa�AonaecFaFara�ngas�n3��FOF7S] WITNESS my d and offi ' seal. w -to I ,Ll:iS, !iii? 13 a NOTARY rFF�i,yS -,r CA' Ij7CP' IJA IMry Uit:'u� �X4 11 Signature Seal: I ►aye+ Egtr Jt420,:sse 0 h�rsFsaano®monooaeoc�000naon� A.P. # END OF DOCUMENT CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 1 CF -1R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 Project Address........ 14365 TROY WAY p. MAGALIA, CA 95954 Documentation Author... ROBERT A. MANGRUM Bu ding e75i�1 Company ................ PARADISE MECH. DESIGN (/ g Telephone .............. (916)877-SAVE/FX 877-7283 Plan Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc Climate Zone........... 11 Field Check/ Date MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE GENERAL INFORMATION BUILDING DEPARTS ENT ��pP€�avEr? VISED Conditioned Floor Area..... 1745 sf Building Type .............. Single Family Detached Construction Type ......... New Building Front Orientation. Front Facing 100 deg (E) Number of Dwelling Units... 1 Number of Stories.......... 1 Floor Construction Type.... Raised Floor (Package E) BUILDING SHELL INSULATION Component Insulation Assembly Type R -value U -Value Location/Comments Wall -13 0.088 Roof rR-30 0.035 ATTIC WALL Roof R43.0. 0.031 Attic Door R-0 0.330 Floor R'1`9 0.037 RAISED FENESTRATION # of Interior Over- �Area, KUl-� Pan- Orientation (sfj `Value';es Shading/ Description Exterior Shading hang/ Framing Fins Type Window Front (E) 20.0 0.640 2 None None Yes Metal Window Front (E) 20.0 0.640 2 None None Yes Metal Window Front (SE) 15.0 0.640 2 None None None Metal Window Front (E) 15.0 0.640 2 None None None Metal Window Right (NE) 15.0 0.640 2 None None None Metal Window Left (S) 0 0.640 2 None None None Metal -Window Left (S) 4. .640 2 None None None Metal BUILDING DEPARTS ENT ��pP€�avEr? VISED CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 2 CF -1R Project Title.......... RUTLEDGE RESIDENCE nates nti/1a/aa MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE FENESTRATION Equipment Type Furnace ACPackage {HVAC SYSTEMS Minimum jDucts Efficiency Location 0.785 AFUE Crawlspace 12.00 SEER �Cr` awlspace WATER -HEATING -SYSTEMS Duct Thermostat R -value Type R-4.2 Setback R-4.2 Setback Number Tank in Energy Size Tank Type Heater Type Distribution Type System CFactor (gal) Storage Gas k PipeInsulation 10 EF 50 External' Insulation R-Ealue R:1.2 # of Interior Over- Orientation U-1 �(sf) Pan- Shading/ Exterior hang/ Framing Value' es Description Shading Fins Type F Window Back (W) 53.0 0.640 2 None None Yes Metal Window Back (W) 34.0 0.640 2 None None Yes Metal Window Back (W) 20.0 0.640 2 None None Yes Metal Window Right (N) 12.0 0.640 2 None None Yes Metal Skylight Horz 0.590 2 None None None Wood _k Skylight Horz.0 0.590 2 None None None Wood VSkylight Horz 8.0 0.590 2 None None None Wood THERMAL MAS TypeExposed Area Thickness (sf) (in) Location/Comments InteriorVert Yes 50 4.0 STOVE HEARTH InteriorVert Yes 17 4.0 STOVE HEARTH InteriorVert Yes 138 1.0 BATHS InteriorHorz Yes 71 1.0 BATHS/KITCHEN InteriorHorz Yes 20 1.5 ENTRY Equipment Type Furnace ACPackage {HVAC SYSTEMS Minimum jDucts Efficiency Location 0.785 AFUE Crawlspace 12.00 SEER �Cr` awlspace WATER -HEATING -SYSTEMS Duct Thermostat R -value Type R-4.2 Setback R-4.2 Setback Number Tank in Energy Size Tank Type Heater Type Distribution Type System CFactor (gal) Storage Gas k PipeInsulation 10 EF 50 External' Insulation R-Ealue R:1.2 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 3 CF -1R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE SPECIAL FEATURES/REMARKS WATER HEATER: AO SMITH FGR -50-0.60 OR EQUIV. 1 CARRIER 48TLX042 AFUE 78.5 SEER 12.0 CERTIFICATE OF COMPLIANCE: RESIDENTIAL Page 4 CF -1R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM CF -1R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to comply with Title -24, Parts 1 and 6 of the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the individual with overall design responsibility. When this certificate of compliance is submitted for a single building plan to be built in multiple orientations, any shading feature that is varied is indicated in the Special Features/ Remarks section. DESIGNER or OWNER Name.... MIKE RUTLEDGE Company. PARADISE CONST. Address. 6 5W '. vo 1e y Tow"r tP'q oz sa. PI -r V__ Phone ... 'Z- Z e, e5 7_ License. e -IS 2 - Signed.. date) ENFORCEMENT AGENCY Name .... Title... Agency.. Phone... Signed.. (date) DOCUMENTATION AUTHOR Name.... ROBERT A. MANGRUM Company. PARADISE MECH. DESIGN Address. 5797 CLARK ROAD SUITE 16 PARADISE, CALIFORNIA 959 Phone... (916)877-SAVE/FX 877-7283 Signed. . date) COMPUTER METHOD SUMMARY Page 5 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 Pro'ect Address 14365 TROY WAY MAGALIA, CA 95954 Documentation Author... ROBERT A. MANGRUM Company ................ PARADISE MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field Check Date MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE Energy Use (kBtu/sf-yr) MICROPAS4 ENERGY USE SUMMARY Standard Design Proposed Compliance Design Margin Space Heating.......... 12.68 12.87 -0.19 Space Cooling.......... 14.37 12.84 1.53 Water Heating.......... 12.87 10.47 2.40 Total 39.92 36.18 3.74 *** Building complies with Computer Performance *** GENERAL INFORMATION Conditioned Floor Area..... Building Type .............. Construction Type ......... Building Front Orientation. Number of Dwelling Units... Number of Building Stories. Weather Data Type.......... 1745 sf Single Family Detached New Front Facing 100 deg (E) 1 1 ReducedYear Floor Construction Type.... Raised Floor (Package E) Number of Building Zones... 1 Conditioned Volume......... 14752 cf Footprint Area ............. 1784 sf Ground Floor Area.......... 1784 sf Slab -On -Grade Area......... 0 sf COMPUTER METHOD SUMMARY Page 6 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE Glazing Percentage......... 15.2 % of FA Average Ceiling Height..... 8.5 ft BUILDING ZONE INFORMATION Floor # of Vent Special Area Volume Dwell Cond- Thermostat Height Vent Area Zone Type (sf) (cf) Units itioned Type (ft) (sf) HOUSE Residence 1745 14752 1.00 Yes Setback 2.0 n/a OPAQUE SURFACES Area U- Insul Act Solar Form 3 Location/ Surface (sf) value R-val Azm Tilt Gains Reference Comments HOUSE 1 Wall 205 0.088 R-13 100 90 Yes W.13.2X4.16 2 Wall 17 0.088 R-13 145 90 Yes W.13.2X4.16 3 Wall 17 0.088 R-13 55 90 Yes W.13.2X4.16 4 Wall 363 0.088 R-13 190 90 Yes W.13.2X4.16 5 Wall 269 0.088 R-13 280 90 Yes W.13.2X4.16 6 Wall 212 0.088 R-13 10 90 Yes W.13.2X4.16 7 Roof 48 0.035 R-30 10 90 Yes R.30.2X12.16 ATTIC WALL 8 Wall 118 0.088 R-13 10 90 No W.13.2X4.16 9 Wall 48 0.088 R-13 100 90 No W.13.2X4.16 10 Roof 1372 0.031 R-30 0 0 Yes R.30.2X4.24 Attic 11 Roof 413 0.031 R-30 100 24 Yes R.30.2X4.24 Attic 12 Door 20 0.330 R-0 100 90 Yes None 13 Door 18 0.330 R-0 10 90 No None 14 Floor 1784 0.037 R-19 0 0 No FC.19.2X8.16 RAISED FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description HOUSE 1 Window 20.0 2 Metal Slider 0.640 100 90 0.88 0.78 None 2 Window 20.0 2 Metal Slider 0.640 100 90 0.88 0.78 None 3 Window 15.0 2 Metal Slider 0.640 145 90 0.88 0.78 None COMPUTER METHOD SUMMARY Page 7 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE FENESTRATION SURFACES # of Vent SC SC Interior Area Pan- Frame Open U- Act Glass Int Shading/ Surface (sf) es Type Type value Azm Tlt Only Shade Description 4 Window 15.0 2 Metal Slider 0.640 100 90 0.88 0.78 None 5 Window 15.0 2 Metal Slider 0.640 55 90 0.88 0.78 None 6 Window 21.0 2 Metal Slider 0.640 190 90 0.88 0.78 None 7 Window 24.0 2 Metal Slider 0.640 190 90 0.88 0.78 None 8 Window 53.0 2 Metal Slider 0.640 280 90 0.88 0.78 None 9 Window 34.0 2 Metal Slider 0.640 280 90 0.88 0.78 None 10 Window 20.0 2 Metal Slider 0.640 280 90 0.88 0.78 None 11 Window 12.0 2 Metal Slider 0.640 10 90 0.88 0.78 None 12 Skylight 4.0 2 Wood Fixed 0.590 100 0 0.88 1.00 None 13 Skylight 4.0 2 Wood Fixed 0.590 100 0 0.88 1.00 None 14 Skylight 8.0 2 Wood Fixed 0.590 100 0 0.88 1.00 None OVERHANGS AND SIDE FINS Window- Overhang Left Fin Right Fin - Area Left Rght Surface (sf) Hght Wdth Dpth Hght Ext Ext Ext Dpth Hght Ext Dpth Hght HOUSE 1 Window 20.0 4.0 5.0 7.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 2 Window 20.0 4.0 5.0 7.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 8 Window 53.0 6.6 8.0 2.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 9 Window 34.0 4.0 8.0 2.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 10 Window 20.0 4.0 5.0 2.5 0.0 n/a n/a n/a n/a n/a n/a n/a n/a 11 Window 12.0 4.0 3.0 1.0 0.0 n/a n/a n/a n/a n/a n/a n/a n/a THERMAL MASS Area Thick Heat Conduct- Surface Mass Type (sf) (in) Cap ivity R -value Location/Comments HOUSE 1 InteriorVert 50 4.0 21.0 0.59 R-0.0 STOVE HEARTH 2 InteriorVert 17 4.0 21.0 0.59 R-0.0 STOVE HEARTH 3 InteriorVert 138 1.0 24.0 0.67 R-0.0 BATHS 4 InteriorHorz 71 1.0 24.0 0.67 R-0.0 BATHS/KITCHEN 5 InteriorHorz 20 1.5 24.0 0.67 R-0.0 ENTRY COMPUTER METHOD SUMMARY Page 8 C -2R Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -FORM C -2R User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE System Type HOUSE Furnace ACPackage Tank Type 1 Storage HVAC SYSTEMS Minimum Duct Duct Duct Efficiency Location R -value Efficiency 0.785 AFUE Crawlspace 12.00 SEER Crawlspace WATER HEATING SYSTEMS R-4.2 0.830 R-4.2 0.860 Number Tank External in Energy Size Insulation Heater Type Distribution Type System Factor (gal) R -value Gas PipeInsulation 1 0.60 50 R-12 SPECIAL FEATURES/REMARKS WATER HEATER: AO SMITH FGR -50-0.60 OR EQUIV. 1 CARRIER 48TLX042 AFUE 78.5 SEER 12.0 HVAC SIZING Page 9 HVAC Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 Project Address........ 14365 TROY WAY MAGALIA, CA 95954 Documentation Author... ROBERT A. MANGRUM Building Permit # Company ................ PARADISE MECH. DESIGN Telephone .............. (916)877-SAVE/FX 877-7283 Plan Check Date Compliance Method...... MICROPAS4 by Enercomp, Inc. Climate Zone........... 11 Field ChE-Ek-7 Che-Ek-7Date MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -HVAC SIZING User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE GENERAL INFORMATION Floor Area ................. 1745 sf Volume ..................... 14752 cf Front Orientation.......... Front Facing 100 deg (E) Sizing Location............ PARADISE Latitude ................... 39.8 degrees Winter Outside Design...... 30 F Winter Inside Design....... 70 F Summer Outside Design...... 99 F Summer Inside Design....... 78 F Summer Range ............... 34 F Interior Shading Used...... Yes Exterior Shading Used...... Yes Overhang Shading Used...... Yes Latent Load Fraction....... 0.30 Description HEATING AND COOLING LOAD SUMMARY Heating Cooling (Btuh) (Btuh) Opaque Conduction and Solar...... 9823 4499 Glazing Conduction ............... 6752 3545 Glazing Solar .................... n/a 8398 Infiltration ..................... 8391 2532 Internal Gain .................... n/a 2100 Ducts ............................ 2497 1054 Sensible Load .................... 27462 22127 Latent Load ...................... n/a 6638 Minimum Total Load 27462 28765 HVAC SIZING Page 10 HVAC Project Title.......... RUTLEDGE RESIDENCE Date........ 06/14/94 MICROPAS4 v4.02 File-2RUTLEDG Wth-CTZ11S92 Program -HVAC SIZING User#-MP1342 User -PARADISE MECH. DESIGN Run-RUTLEDGE ENHANCED CASE Note: The loads shown are only one of the criteria affecting the selection of HVAC equipment. Other relevant design factors such as air flow requirements, outdoor design temperatures, coil sizing, availability of equipment, oversizing safety margin, etc., must also be considered. It is the HVAC designer's responsibility to consider all factors when selecting the HVAC equipment. Mandatory Measures Checklist: Residential MF -1 R NOTE: Lownse restoenual buildings subject to the Standards must contain these measures regardless of the compliance approach used. Items marked with an asterisk (') may be Superseded by,more stringent compliance requirements listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features noted shall be considered by all parties as binding minimum component performance specifications for the mandatbry measures whether they are shown elsewhere in the documents or on this checklist only. DESCRIPTION DESIGNER ENFORCEMENT Building Envelope Measures • §150(a): Minimum R-19 ceiling insulation. §150(b): Loose fill insulation manufacturer's labeled R -Value. • §150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass wags). §I50(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors. §150(1): Slab edge insulation -water absorption rate no greater than 0.3%. water vapor transmission rate no greater than 20 pemvinch. §118: Insulation specified or installed meets California Energy Commission quality standards. Indicate type and form. §116.17: Fenestration Products, Exterior Doors and InfiltratioNExfitradon Controls a. Doors and windows between conditior>ed and unconditioned spaces designed to limit air leakage. It. Manufactured fenestration products have label with certified U -value, and infiltration certification c. Exterior doors and windows weatherstripped: all joints and penetrations caulked and sealed. §150(9): Vapor barriers mandatory in Climate Zones 14 and 16 only. §150(f): Special infiltration barrier installed to comply with §151 meets Commission quality standards. §150(e): Installation of Fireplaces. Decorative Gas Appliances and Gas Logs 1. Masonry and factory -built fireplaces have: a Closeable metal or glass door b. outside air intake with damper and contra a Rue damper and control 2 No continuous burning gas pilots allowed. Space Conditioning, Water Heating and Plumbing System Measures §1.10 -13: HVAC equipment water heaters, showerheads and faucets certified by the Commission. §1500: Setback thermostat on all applicable heating systems. §150(1): Pipe and Tank Insuiation 1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation blanket (R-12 or greater) or combined intenonextertar insulation (R-16 or greater). 2 Fust 5 feet of pipes closest to water heater tank, non -recirculating systems, insulated (R-4 or greater). 3. All buried or exposed'piping insulated in recirculating sections of hot water system. 4. Cooling system piping oelow VF insulated. 5. Piping insulated between heating source and indirect hot water tank • §I50(m): Ducts and Fans I. Ducts constructed. installed and seated to comply with UMC Sections 1002 and 1004: duan insulated to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space. 2 Exhaust tan systems nave backdraft or automatic dampers 3. Gravity ventiiapne systems serving conditioned space have either automatic or readily accessible. manually operateo camoers.. §114: Pool and Spa Heating Systems and Equipment 1. System is cerdfieo whin 78% thermal efficiency, on-off switch, weatherproof operating instructions. no eiectric resistance heating and no pilot light 2 System is instaileo with: a. At least 36' cine oetween filter and heater for future solar heating. b. Cover for outcoor pools or outdoor spa 3. Pool system nas crrecconar inlets and a circulation pump time switch. §t 15: Gas-iireo centra, r•.lrnace. pool heater, spa neater or household cooking appdance have no continuously burin p:iot uaht. (Exception: Non-enectrtcal cooking appliance with pilot < 150 8twtv.) Lighting Measures § 150(kl: 40 lumens, -war, or greater for general lighting In kitchens and rooms with water closets: and recessed ceriing nxtures rC iinsurlation ccverh approved. COMPLIANCE STATEMENT This certificate of compliance lists the building features and performance specifications needed to oomptywith rifle 24, Pans 1 and 6, of the California Code of Regulations, and Cte administrative regulations to implement them. This certificate has been signed by Cie initWidual with overall design responsibility. When this certificate of compliance is sttbmil ed for a single building plan to be built in mtdtipte orientations. any shading feature Chat is rallied is irtdcated in the special FeabsesfRemarfts senor. Designer or Owner (per Suaine" a profeeaiom Co") Documentation Author . = Name: Name: ride/Firm: rldw nrm: Address: Address: Telephone: Uc. t: (69rature1 (date) Enforcement Agency Name: Title: Agency: Telepnone: (srgnaturerstamp) - (aatel Telephone: (Signature) (date) Certificate of Compliance: Residgntial _ ._ Climate Zone 11 i Project Title Building Permit it1 Project Addren Checked By / Due Documentation Author Telephone Enforcement Agency Use Only BUILDING DATA Area % Conditioned Floor Area Number of Stories North Slab/Raised Floor Number of -Units East South [ ] Single Family Detached (SFD) [ ] Addition Alone West [I Single Family Attached (SFA) [ ] Existing Building Skylight [ ] Multi -Family (MF) [ ]. Existing -Plus -Addition Total 1 B UrLDING SHELL INSULATION Component Insulation Locaiiotr/Comme,'Ats Type R -Value (attic, to swage, typi=eL etc-) Roof........».» Roof............. WaII.............. Wall.......... Floor ............. tFloor............ . Slab Edge .... i FENESTRATION Shading Devices -f=enestration Area Type interior Exterior Overhang Framing Type Orientation (sf) (single, double) (roller blind etc.) (shadescreea. eta) (yesmo) (meW/wood) North ( ) North i ) East ( ) East ( ) South ( ) Sou th ( ) West ( ) West ( ) Skylight....... THERMAL IMASS Type/Coverirg Area Thickness j (stab/exposed. tile, etc.) (SO (inches) Location/Dcscriotion (kitchen, bath. etc.) HVAC SYSTEMS titinimum Duct Type (furnace, air Efficiency Location Duct Heat Pump conditioner: hemouinp) (AFuff,SE£R,HSPF) (atac.cw-) R -Value Thermostat Type (sRlit or pkg) . II OT NATER SYSTEMS Tank R Value ;vStt:lii Tvt7e (sioraRe gay, ale.) Cavacity Number Enerfzy Factor Ext. Tank Tns_ TH c_ rT; i,rr_ry�>a, SPECIAL FEATURES/REMARKS �� Point System Summary: Climate Zone 11 1. Ceiling Insulation AFUE or HSPF Duct Effie. (1 story: Etfecave AFUE or 178% or 6.81 0.83:24. story: 0.881 or HSPF Adiustnnent (01 R -value 1381 U -value 10.0291 2. Wall Insulation 0.81: 2+ story: 0.871 or -5 -4 R -value 1191 U -value 10.065) 3. Raised Floor Insulation 0 or •0 0 R -value 1191 U -value 10.0371 4. Slab Edge Insulation .61 or singe- Single - R -value 101 F2 facttx (0.751 5. Infiltration Any Ducts in Unconditioned Space? ( Y / N) (Y] 6. Fenestration Heat Loss Type Ll -value 10.651 Tow % Fenes,1161 7. Fenestration Heat Gait % Fenestration SCShade open Eff. % Fenes. North _ X East X South X = West X = Skylight X = Overhangs? ( Y / N ) S. Interior Thermal Mass or % Exp. Slab 1201 Int Mass/CFA 9. Exterior Wall Mass Ext Wad Mass 10. Heating System 11. Cooling System Shade Elf. Ratio Point Scores Sum 1-6 Sum 7-9 X Number of stones AFUE or HSPF Duct Effie. (1 story: Etfecave AFUE Zonal Controi 178% or 6.81 0.83:24. story: 0.881 or HSPF Adiustnnent (01 X = R-0 SEER 110.01 Duct Effie- 11 story: Effective SEER Zonaa•Canttd 0.81: 2+ story: 0.871 Adiustment (O1 12. Water Heating System 1 HeaterType En 53actor Ext ins. 2 -value lS�O1 (�• 1 11 System 2 Heater Type (None) Energy Factor Ext Ina. A -value 1. Ceiling Insulation R-value Number of stones Fami R -varus One Two thies - R-0 -74 -48 -27 R-19 -5 -4 -2 R-30 .1 -1 0 R-38 •0 0 0 2. Wall Insulation Irmliatlon in Floor .66 .61 Numoer of stones singe- Single - One Two Three Family Family wilti- R-value Detached Attactso Fami R-0 -72 -57 -43 R-11 -7 -6 -4 R-13 -5 -4 -3 R-15 -4 •3 -2 . R-19 0 0 0 R-21 1 1 1 3. Raised Floor Insulation .81 .76 Irmliatlon in Floor .66 .61 Numoer of stones .51 R-�raiue One Two Three R•0 -14 •9 •5 R-11 -3 .2 -1 8.19 0 0 0 R-30. 2 1 Auxiiiary Input Distnbunon 1Nonel ISTD1 Auxftiary input Distrix ution Point Total: 4. Slab Edge Insulation. -5 Numoer of Stones -2 R -value One Two Three R-0 0 0 0 R-5 6 4 2 R-7 7 4 2 6. Fenestration Heat Loss .51 5. Infiltration (Duct Air Leakage) Ducts in Unconditioned Space 0 No Ducts in Unconditioned Space 3 7. Fenestration Heat Gain (based on Shade Eftecuveness Ratio) Elf -5 North -2 East South •15 71s1ry8gAf- U•VW- us .23 %, .87 .67 .52 .51 .87 .67 .52 51 .87 .67 .52 Total 1.31 1.21 1.11 1.01 .91 .81 .76 .71 .66 .61 .56 .51 .46 .41 .36 .35 Perera or to to to to to to to to . toto .11 to to to to or Fenestration more 130 1.20 1.10 1.00 .90 .80 .75 70 --:65 .1 - 60 55 .50 45 40 less 507. -100 -76 -b9 -62 -55 -48 -41 -38 .34 •31 -27 -24 -20 -17 -13 -10 407. -77 -58 -52 -47 41 •36 -30 -27 •25 -22 -19 .16 .13 .11 -8 -5 35% -66 -19 -44 -39 -34 -29 -25 -22 •20 .17 •15 •12 -10 -7 .5 -3 I 30% -54 -40 -36 -31 -27 -23 .19 •17 .15 .13 •11 -8 -6 -4 •2 0 287. -50 -36 -32 •28 •25 -21 -17 -15 -13 -11 •9 -7 -5 -3 -1 1 26% -45 -33 -29 -25 -22 •18 -14 .13 .11 -9 •7 -5 -4 -2 0 2 24% -t1 -29 - 226 -22 -19 •16 -12 -11 -9 -7 -6 .4 -2 -1 1 3 227. -36 -25 -22 •19 -16 -13 -10 -8 •7 •5 .4 ' .2 -1 1 2 4 20% 11 -22 -19 -16 -13 -11 -8 .6 -5 -1 -2 -1 1 2 3 5 18% -27 -18 -16 -13 -11 -8 -6 -4 -3 -2 .1 1 2 3 4 6 16% -22 -14 -12 10 •8 -6 -3 - •2 -1 0 1 2 3 4 6 . 7 14% •18 -11 -9 -7 .5 •3 -1 0 1 2 3 4 5 6 7 8 '12% -13 .7 .6 -4 -2 -1 1 2 3 4 4 5 6 7 8 9 107. -8 -c .2 -1 1 2 3 4 5 5 6 7 8 8 9 t0 8% -t 0 1 2 3 4 6 6 7 7 8 8 9 9 10 11 7. Fenestration Heat Gain (based on Shade Eftecuveness Ratio) Elf -5 North -2 East South •15 71s1ry8gAf- .26 .23 %, .87 .67 .52 .51 .87 .67 .52 51 .87 .67 .52 .51 .87 .67 .52 .51 .67 .66 Far.. or to to or or to . to or I or to to or or to to or or or tslra- NM more .86 .fib less more .86 .66 less more .86 .66 less more .86 .66 less more less 18% -5 -4 ' .3 -2 -21 -20 •15 .12 .26 .23 .16 •12 -36 •32 -23 -16 -75 .50 16% -4 -4 .2 -1 •18 -16 .13 .10 .21 .19 .13 •9 -31 •27 •19 .14 .65 44 14% -4 -3 .2 •1 -14 -13 .11 -8 -16 -14 -10 -7 -26 •23 -16 -11 .55 •38 12% -3 -2 .1 -1 -11 -10 -8 .6 •12 .10 .7 -4 .21 •18 •13 -8 46 .31 11% -2 -2 •1 0 -10 -9 -7 .6 •10 -8 .5 .3 -19 -16 -11 .7 .41 .28 MY. -2 •2 .1 0 -8 -8 .6 •5 -0 •7 .4 -2 -16 -14 -9 -6 -37 -25 9% =2 -1 .1 0 -7 -7 •5 .4 -6 .5 .3 •1 •14 . -12 -8 -5 •32 -22 8% -1 -1 -1 0 -6 •5 -4 .4 .4 -4 .2 0 -11 -10 -6 -4 -28 -19 77- -1 -1 0 0 -5 -4 -4 .3 •3 .3 .1 0 -10 -8 -5 -3 -24 .17 6%, •1 -1 0 0 -4 .4 •3 •2 -2 -2 •1 0 -8 -7 -4 -2 -2o •t4 5% -1 0 0 0 •3 -3 .2 .2 .2 •1 0 0 -6 •5 .3 -1 •16 -12 4% 0 0 0 0 -2 •2 -1 •1 i .1 0 1 -4 .4 -2 0 •12 •10 3% 0 0 0 0 -1 .1 -1 0 0 0 0 1 -2 -2 0 1 -9 -7 2% 0 0 0, 1 0 0 0 0 0 0 1 1 0 0 1 2 -6 -5 1% 1 1 1 1 1 1 1 1 0 0 0 0 1 1 2 2 -3 -2 C% 1 1 1 1 1 1 1 1 0 0 0 0 3 3 3 3 0 0 8. Interior Thermal Mass Exterior Single• M ethod A (Slabon-grade Construction Only) Perera one Family Two Family Three Exposed Ston •24 to Stones 0 Stories 0 0.20 •3 3 -2 0.40 .1 10 4 •2. 9 .1 6 .1 20 10 0 1.00 0 12 0 30 - '17 1 10 1 18 1 40 1.60 3 17 . 2 1.80 1 50 14 4 24 3 14 2 60 1. 5 0 3 7.4 2 70 4 6 2 4 1 2 80 7.6 8 , 7 5 4 3 90 95% 9 8.0 6 9 3 100 4 10 100% 6 8.5 4 11 9 Method B 2 AC Ira Effecdve AFUE or HSPF Slab Floor .5 Raised Floor Mass more Stories Stones /CFA One Two Three One Two Three 0.0 -11 -8 -6 .1 -1 0 0.1 -10 .7 -6 0 0 0 0.3 -9 -6 .5 1 1 1 0.5 -8 -5 -4 2 2 2. 1.0 -6 •3 -1 4 4 5 1.5 -4 .1 1 6 6 6 2.0 -2 2 4 8 8 8 2.5 1 3 5 9 9 9 3.0 3 1 . 5 11 10 10 4.0 4 6 7 13 13 13 5.0 4 6 8 14 14 14 6.0 5 7 9 15 15 15 7.0 7 8 10 16 16 16 8.0 8 9 11 18 17 17 9. Exterior Wall Thermal Mass Exterior Single• single- Multi Wall Family Family Family Mass Detached Attamed •24 to 0.00 0 0 0 0.20 3 3 2 0.40 7 5 4 0.60 9 8 6 0.80 12 10 7 1.00 14. 12 9 1.20 - '17 13 10 1.40 18 14 11 1.60 21 17 . 13 1.80 23 18 14 2-00 24 19 14 10. Heating -System Houses with Ducts (R-4.2) . 1000 SEER Quiff to Sum of 7-9 Houses With Ducts (R-42) 1493 Spirt Potg -25 or •24 to -14 to -4 to Sum of 1.6 AC AC Gas Split Pkg -25 -24 •14 -4 +6 16 AFUE HP HP or to to to to or - H VF HSPF less -15 •5 +5 +15 more 787. 6.8 6.6 • 0 0 0 0 0 0 80% 7.0 6.8 1 •1 1 1. 0 0 85% 7.4 7.2 5 4 3 2 2 1 90% 7.8 7.6 8 7 5 4 3 1 95% 8.3 8.0 11 9 7 5 4 2 100% 8.7 8.5 13 11 9 7 4 2 AC AC Effecdve AFUE or HSPF -15 .5 +5 (AFUE or HSPF x duct dnciency) more Effective 0.93 Sum of 1-6 4 5.0 Gas Spirt Pkg .-25 -24 -14 -4 +6 16 AFUE HP HP or to to to to or -6 NSPF NSK less -15 •5 - +5 +15 morn One Story House 0 0 0 8.1 7.9 0 33% 2.9 2.8 -62- -53 4A -34 -25 -16 407. 3.5 3.4 -40 -34 -28 -22 -16 -10 50% 4.4 4.2 -19 -16 -13 -10 -7 -5 60% 5.2 5.1 -4 -4 -3 -2 -2 -1 64% 5.6 5.4 0 0 0 0 0 0 707. 6.1 5.9 6 5 4 3 2 1 800/. 7.0 6.8 13 11 9 7 5 3 90% 7.8 7.6 19 16 13 11 8 5 100% 8.7 8.5 24 20 17 . 13 10 6 Two or Three Story House 1518 -11 A -7 .4 33% 2.9 2.8 -69 -58 -48 -37 -26 -15 407. 3.5 3.4 -46 -39 -32 -24 -17 -10 50% 4.4 4.2 -24 -20 -16 -13 -9 -5 60% 5.2 5.1 -9 -8 -6 •5 -3 -2 690/6 6.0 5.8 0 0 0 0 0 0 70% 6.1 5.9 1 1 1 1 0 0 8D% 7.0 .6.8 2 9 8 6 5 3 2 90% 7.8 7.6 15 13 10 8 6 3 100% 8.7 8.5 20 17 14 11 8 4 Zonal Comml Adjustment - System Type Resistance 6 4 3 2 1 0 Olney 3 3 2 1 1 0 Adj!axmeat for No Tank Inmtatim Number of Water Hans Water Heater Tvos One Two SGSO .2 •5 SG75 •3 a SE •5 -9 HP .2 -4 11. Cooling System .1 Houses with Ducts (R-4.2) . 1000 SEER Quiff to Sum of 7-9 1000 1493 Spirt Potg -25 or •24 to -14 to -4 to +6 to 16 or AC AC less •15 •5 .5 +15 more 10.0 9.7 0 0 0 0 0 0 11.0 10.7 4 3 2 2 1 0 120 11.6 9 6 5 3 1 0 13.0 12.6 ' 11 9 6 4 2 0 14.0 13.6 13 .11 8 5 2 0 15.0 14.6 16 12 9 6 2 0 0.48 .2 Effective SEER -1 -12 -7 .2 (SEER x duct efficiency) 058 Elf SEER 6 5 .5 Sum of 7.9 A Split Pacg -25 or -24 to -14 to -4 to .6 to 16 or AC AC less -15 .5 +5 +15 more One Story House 0.93 -17 4 5.0 4.9 •29 -23 -17 -11 -4 0 6.0 5.8 -16 •13 A -6 -2 0 7.0 6.8 •7 -6 -4 •3 -1 0 8.0 7.8 -1 0 0 0 0 0 8.1 7.9 0 0 0 0 0 0 9.0 8.7 5 4 3 2 1 0 10.0 9.7 9 7 5 3 1 0 11.0 10.7 12 10 7 4 2 0 12.0 11.6 15 12 9 6 2 0 13.0 126 18 14 10 6 3 0 14.0 13.6 20 16 11 7 3 0 15.0 14.6 22 17 12 8 3 0 Two or Three Story House 0.93- -16 5.0 4.9 -35 -27 -20 -13 -5 0 6.0 5.8 -21 -17 -12 -8 .3 0 7.0 1518 -11 A -7 .4 -2 0 8.0 7.8 1 -4 -3 -2 •1 -1 0 8.7 8.4 0 0 0 0 0 0 9.0 8.7 2 1 1 1 0 0 10.0 9.7 6 5 4 2 1 0 11.0 10.7 10 8 6 4 1 0 12.0 11.6 13 10 7 5 2 0 13.0 12.6 . 16 12 9 6 2 0 14.0 13.6 18 14 10 6 3 0 15.0 14.6 20 16 11 7 3 0 Zonal Control Adjustment A8 6 5 4 2 1 0 House S1:a Adjustment Boise Size (rte; su tmal Ins 1000 Witterafeamtg Quiff to Pam Smre 1000 1493 -30 47 .5 .25 •14 4 -20 -11 4 •15 -9 •7 -10 -15 2 •5 -3 t 0 0 0 5 3 1 10 9 2 15 9 3 20 11 3 25 14 4 Hoose Sin Adjustment House We (r-) suotOW ism 2000 Water Heating to or Port Scare .1999 more -30 0 3 -3 0 2 -20 0 2 -15 0 1 .10 0 1 .5 . 0 0 0 0 0 5 0 0 10 0 t 15 0 t 20 0 2 25 0 -2 12. Water Heating One Water Heater - No AuzMacy Czsdus Dim tilsftin SyU m2 Rene Systems Water climates Energy STD WR tripe No Toner Oemd Fkmer Tvoel Zones Fatsm POu Insul ctrl SG50 All am O 3 1 -0 -5 0 0.63 5 8 6 .4 0 5 0.73 8 11 9 o 4 a SG75 All 0.48 .2 1 -1 -12 -7 .2 058 3 6 5 .5 -1 A am 7 10 8 -1 3 7 SE AS 0.87 -2D -12 -17 .41 32 -19 0.93 -17 4 -13 3a -28 -16 IG` N 080 2 V. 3 IE All 0.93 -21 -12 MP 611,13,15 1.80 4 7 5 -5 .1 4 Two Wau r Heaters - No A=aLu 7 Credlsr SG50 As am -7 .4 -6 -17 -12 -7 0.63 1 5 3 -8 4 1 0.73 6 10 8 -2 2 7 SG75 All 0.48 •12 -0 -11 -22 -17 -12 0.58 4 3 0 -11 a -1 0.68 a 9 7 .4 1 6 SE Jul o.87 -22 a4 -19 46 -35 -22 0.93- -16 -7 -12 •39 -28 .15 :G /Ira 0.80 .4 •1 .2 IE All 093 -21 •12 HP 611,13.15 1.80 .1 3 1 •10 •6 0