HomeMy WebLinkAbout065-290-012L
65-29-12
Frank Schwander
23 Magnolia Way, lot 31, SD0#l, Maga.
Permit #6626-79B(new ramada & patio
roof/MH) ;
065-29-07012 93-3190 B
VILLANOVA, SAM & JACKIE
14791 MAGNOLIA, MAGALIA 1
CONTR : DON BANTUM
AWNING/MH
I
is
065- Z916 --TOO6
5
Q
f I--- - - -- -.%—, -
RESIDENTIAL
065-29-0-012 93-3190 B
VILLANOVA, SAM & JACKIE
14791 MAGNOLIA, MAGALIA
CONTR: DON BANTU
AWNING/Mli
�j
2
V=OK
O = Not OK
- = Not Applicable "
=Not Ready, -'
M
RESIDENTIAL (Single & Duplex)
Date/Initials UNDERFLOOR (Plans) OK except #'s
1. Zoning -Setbacks -Easements -Flood -Slope
2. Ftg., Main; Soils-Elec. Grnd.-/ P' Fig. Depth
3. Ftg., Garage; Soils-Steel-Elec. Grnd. / /" Ftg. Depth
4. Ftg., Porches & Decks; Soils -Steel-/ /Ftg. Depth
5. Stemwalls, Main; Steel-Blockouts-Wrapped
6. Stemwalls, Garage; Steel-Blockouts-Wrapped
6a. Hold Downs and Special Anchors
7. Slab; Steel -Wrapped
8. Piers -Fireplace Ftg.-Steel
9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test
10. UF. Gas Pipe; Size -Anchors - yard gas piping: size -test
11. Water Pipe; Test -Anchor -Regulator -Service Test
12. Electric; Underground
13. Plenums & Ducts; Clearance -Materiel -Support -Ins.
14. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
15. Access & Ventilation
16. Insulation
Date/Initials PLUMBING (Permit) OK except #'s
16. Water Htr.; Vent -Access -Combustion Air -Baffle
17. Water Pipe; Test & Anchor -Neil Protection
18. D.W.V.; Test -Fittings & Anchor -Nasi Protection
19. Shower Pan; Test, First Floor -Tub Access
20. Test Tub & Shower, Second Floor -Tub Access
21. Gas Pipe; Size & Anchors
Date/initials ELECTRICAL (Permit) OK except #'s
22. Fixture & Transformer Clearance -Ins. Protection
23. Elec. Receptacles Spacing -Lights & Switches at Doors
24. Size Boxes & No. of Conductors -Stapled
25. Romex Installed Close to Edge of Studs & C.J.
26. Equip. Ground made up w/Meth. Fastners-Bond Gas & Water
27. 2 Appliance Circuts in Kitchen & Conductor Size/GFI
28. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga.
Cu or Al
29. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al.
Insulated Neutral ❑ Yes ❑ No
30. Service -Riser Conductors & Ground -Main Disconnect
31. Equip. Clearances Panels -Motors -Meth. Equip.
32. Clothes Closet Light -Shower Light -Spa Light
33. Smoke Detector
Date/Initials MECHANICAL (Permit) OK except #'s
34. A.C. Ducts Insulation & Support
35. Vent Fan; Exhaust above insulation
36. Condensate Drain & Overflow; Size & Grade
37. Furnance-Vent; Access -Comb. Air -Return Air Vent -115 outlet
38. Attic Access & Platform if Furnance in Attic
Date/Initials FRAMING (Plans) OK except #'s
39. Sils, Proper Material & Anchors
40. Walls Studs -Nailing, Spacing & Bracing -Plates -Sound
41. Bearing Wells over Girders & Floor Nailing
42. Draft Stop in Walls (rat proof)
43. Fire Stops; Furred Ceilings -Stairs -Chases -Tub
44. Headers & Beam -Size & Bearing
Date/Initials FRAMING (Continued)
45. Hangers -Post Caps -Anchors -Connectors
46. Cing. Joist-Rftr. ties -Puri In' -roof Brec-Truss-Shthng.-Rfng.
47. Fireplace Ties or Type A Flue -Fireplace Throat clearance
48. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles
49. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions
50. Garage Fire Protection Framing
51. Property Line Firewall & Openings
52. Ext. Doors -One 3' -Check Garage -3rd Story, 2 Exits
53. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
54. plywood on Roof Overhang -Attic Vents -Rafter Outriggers
55. Siding -Nailing Veneer
56. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access
57. Glazing Area -Glass Protection -Skylights -Plastic
58. Shear Walls; Nailing -Bolts
59. Insulation -Walls -Ceilings
60. Infiltration -Wells -Windows
Date/Initials FINAL (Plans) OK except #'s
61. Ext. Steps -Door & Sidelight Protectlon-Landings
62. Smoke Detector
63. Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor -Ducts -Mach. Protection
64. Bedroom Exiting
65. G.F.I. & Bath Fixtures & Tub Access -Spa
66. Elec. Trim & Subpanel; Breaker Sizes & Labels
67. Stairs & Rails
68. Fireplace or Stove; Clearances -Hearth
69. Elec. Outlets at Wood Panel; Int. & Ext.
70. Kit.Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance
71. Elec. Outlets & Receptacles at Kit. Counter
72. Garage Fire Door, Swing -Landing -Closer
73. A.C. Duct in Garage -Damper
74. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.
In Garage; Above Floor -Mach. Protection
75. Plb., Elec. & Mech. Equip. Listed for Location
76. Elec. Receptacles in Garage; (G.F.I.)-Romex Protection
77. Insulation -Foam -Looked in Attic ❑ Yes
78. Guard Rails & Deck Construction -Post Caps
79. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth
Clearance Looked under Floor ❑ Yes
80. Following instld.; Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No;
Planters ❑ Yes ❑ No
81. Stucco; Brown -Finish
82. A.C. Unit; Disconnect, Electrical, Plumbing
83. Vents Above Roof; Plbg: Appliance -Fireplace. -Clearance to
Openings
84. Water Well; Disconnect, Electrical, Plumbing
85. Exterior Elec. Trim; G.F.I. Receptacle -Underground
86. Ventilation Throughout House
87. Glass Protection
88. Corrections from Previous Inspections
89. Gas Test -Meters Tagged; Gas -Electric
90. Water & Sewer Connected -C/O to Grade -HD Approval
91. Energy Compliance Certificate -Other Certificates
Comments at Final:
V=OK
O = Not OK
Not
= Not Readyable MOBILE HOMES
Date/Initials MOBILE HOME UTILITIES (Plans) OK except #'a
1. Zoning Requirements -Setbacks -Easements
2. Soils; Special MH Support Sketch
3. Sewer; Locatlon-Test-Fall-C/O Concrete
4. Water; Location -Test -Easement Needed (Sketch)
5. Electricity; Location-Clearences-Grnd-/ /Amp -Concrete
6. Gas; Location -Teat -Wrap: / /" L"ft.
/ /"Net. or/ P'L"ft./ /"LPG
7. Well Clearance & Disconnect
8. Utility Clearance
Date/Initials MOBILE NOME INSTALLATION (Plans) OK except #'a
1. Zoning Requirements -Setbacks Easements
2. Footings; Size -Spacing -Marriage Line
3.. Gas; MH Test -Demand -Valve -Connector
4. Electricity; MH Test -Crossovers -Breakers -Clearances
5. Drain; MH Test -Fall -Flex Connector
6. Water; MH Test -Regulator -Connector
7. Water and Sewer Connected -C/O to Grade -HD Approval
8. Gas and Electricity Tagged
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
MISCELLANEOUS `
Date/Initial DECKS,, COVERSCARPORTS, GARAGES Plans OK except #'a
L2fjo,&gRequlrements-Setbacks-Easements
Footings; Soils -Size -Depth -Spacing -Connectors -Steel
3. Decks; Griders and/or Joists -Decking -Bracing -Stairs -Rails
4. Wood Awn.; Posts-Beams-Rftrs.-Connectors
Shthg: Rfg.-Bracing
5. Alum. Awn.; Columns-Connections-Spllce-Decal-Enclosures
6. Carports; Windows -Doors
7. Electric
8;;'Frmg; Sils-Anchors-Studs-Rftrs-Trusses
9. Siding; Nailing -Veneer -Stucco -Mesh
1CRRoof; Shthg-Roofing
11. Ext.; Steps -Doors -Landings
6�
Date/Initials POOLS (Plans) OK except H's
1. Setbacks -Easements
2. Soils; Compaction -Structure Stability
3. Pool Structure; Steel -Connections -Thickness
Dead Men -Lining
4. Elec.; Receptacles and Lighting, Distances-GFI
S. Elec.; Pool Lighting; 15 volts-GFI
6. Elec.;Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater
8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg.
Boxes-Enclosures-Panelboards-Ins. to Mein in Conduit
9. Health Department Approval
10. Plumb.; Cir. Test -Water Supply Test
COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION
7 County Center Drive - Oroville, California 95965 - Telephone (916) 538-75413` T NO.
APPLICATION AND PERMIT A
ASSESSOR PARCEL NUMBER
065-290-012
ZONING
RMH
BUILDING PERMIT
OWN%M & JACKIE VILLANOVA
L ONE— 67-4SO.
FT. OCC. BUILDING
280 C 3,640
VALUATION
OWNER'S MAILING ADDRESS
14791 PIAGNOLIA MAGALIA 95954
CONTRACTOR'S NAME
DON BANTUM
TELEPHONE
877-6886
CONTRACTOR'S MAILING ADDRESS
PO BOX 1251 PARADISE CA 95967-1251
Fireplace
CONSTRUCTION LENDER
UNKNOWN
Total Valuation $
LENDER'S MAILING ADDRESS
Filing Fee $
20,00
Permit Fee $
63-00
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee $
40-95
Energy Plan Checking Fee $
ARCHITECT OR ENGINEER'S MAILING ADDRESS
Penalty $
BUILDING ADDRESS
14791 MAGNOLIA DR MAGALIA
PERMIT FEE $
123.95
PLUMBING PERMIT Filing Fee 20.00
Each Trap 7.00
Solar or heat pump water heater
23.00
Water piping
15,00
LOT NO.
SUBDIVISION'S NAME
PARCEL MAP
Each gas water heater or vent
15.00
USE OF STRUCTURE
SF ❑ Duplex O Mobilehome ff Other
SPECIFY
Gas piping system 1 - 5 outlets
15.00
Building sewer
15.00
Mobile Home S G WE
20
` •CO
TYPE OF WORK
New ❑ Addition C Remodel ❑ Utilities ❑ Installation O Other ❑
Describe Work: AWNING
PERMIT FEE $
Contractor
ELECTRICAL PERMIT
Filing Fee 20.00
Main Service ( 800V OR LESS )
200A OR LESS
23.00
Main Service ( 200A TO 1000A )
46.00
NEW CONST. DWELLING OCCUP.
OR ADDNS. ( & ACC. BLDS. )
SO.
3.5C FT.
CONTRACTORS LICENSE LAW
I de lare under penalty of perjury (check one)
I am a licensed under provisions of Chapter 9, Division 3 of the Business and
Professions Code and m license is in full force � effect.
License No. Classification
❑ I, as the owner, or my employees with wages as their sole compensation, will do
the work, and the structure is not intended or offered for sale. (Sec 7044)
❑ I, as the owner, am exclusively contracting with licensed contractors. (Sec 7044)
O 1 am exempt under Sec. Business and Professions Code
forthis reason
NEW CONST. MULTI -OUTLET
•NON-RESID. ( BRANCH CIRCUITS )
@7.50
( POWER APPARATUS )
&SINGLE OUTLET CIR.
Ex. Occup. ( OUTLET OR FIXTURES )
20 @ 1.00
BA0 0
L.
Ex. Occu FIXED APPLOR
p
OUTLETS
( IRESID ID.) EA. )
5.00
Temporary Service
23.00
Mobile Home Facilities
20.00
Misc. Wiring
23.00
WORKER'S COMPENSATION INSURANCE
1 declare under penalty of perjury (check one):
O This permit is for $100.00 (valuation) or less.
O 1 have placed on file with the County of Butte Dept. of Development Services,
Building Division a Certificate of Workmen's Compensation Insurance or a
Certificate of Consent to Self -insure.
I shall not employ any person in any manner so as to become subject to the Worker's
Compensation laws of California.
Notice to Applicant: If after making this statement, should you become subject to the
Worker's Compensation provisions of the Labor Code, you must forthwith comply with
such provisions or this permit will be revoked.
PERMIT FEE S
Contractor
MECHANICAL PERMIT
Filing Fee 20.00
Heating
Cooling
Hood
6.50
Ventilation
PERMIT FEE $
Contractor
I certify that I have read this application and state that the above information is correct.
I agree to comply to all Butte County Ordinances and California State Laws relating to
building construction, and hereby authorize representatives of the County of Butte to
enter upon the above mentioned property for inspection purposes.
1 also agree to save, indemnify and keep harmless the County of Butte against all
liabilities, judgments, costs, and expenses which may in any way accrue against said
County in consequence of the granting of this permit. q
A�!,X g. Date 9 -L 3 — / 3
Signature of Applicant - O Owner O Contractor ❑ Agent
An OSHA permit is required for excavations over 5"0" deep and demolition or
construction of structures over 3 stories in height.
Mobile Home Installation Fee $
Energy Inspection Fee $
ocC
CONST. rrPE
TOTAL FEE $ 123.95
HAZ.
1 O. FEES
I IMP
ft.—J
I F100D,It CDF
PARCEL PD I HD I ISSUE
This permit is hereby issued under the applicable provisions
of the Butte County Code and/or Resolutions to do work
indicated above for which fees have been paid.
D CTOR LIC WORKS Q
ByA&1444 ke, Date
PERMITEXPIRESON % ZZ9
Receipt No. 142779
WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INSPECTOR GOLDENROD -APPLICANT
,7.
TO: Building Department lam/
FROM: Environmental Health
SUBJECT: Sanitation Clearance
�6
A
Owner LocatioY AP#
Plan Approved for: Sewa,,c Disposal Water Supply: Public Private Well
Clearance for be(10111 mobile home. Other ( j
Hold final for:
Final clearance O.K. for:
NOTE:
r /�ys
L -n ironmental He lth Specialist
8/92
e; /,�•A;
llate
COUNTYOF BUTTE -DEPARTMENT OFD� �OPMENTSERVICES -BUILDING DIVISION
7COUNTYCENTERDRIVE -OROVILLE,CALIFORNIA95965- TELEPHONE (916)538-7541
PERMIT APPLICATION DATASHEET
OWNER N'
Proposed Building Use
A. P. No. Q LTJ` - 0 1 U -0 IZ
Building Inspector (?-e� Date 9 /,_' S 2
At time of permit application, I was advised the following data must be submitted prior to permit processing and/or issuance:
1.
DATE RECEIVED BY
All items ha been submitted.........................................
2.
Plot plans, 49 sets, signed by preparer of plans . .......................... -y-
3_
Complete plans, 3/4 sets, signed by preparer of plans . ......................
.4'�
Engineered plans and calcs, 3/4 sets, with wet signature on plans . .............
5.
Hazardous Material Form. ......................................... .
6.
Energy Design Compliance and supporting documentation . ..................
ry 7.
Statement of Intent for Non -Heated and A/C Buildings . ................... ... .
8.
Engineered truss details and layout in duplicate (required prior to plan check). ....
9.
Mobilehome data and manufacturer's installation instructions, 2 sets. ...........
10.
11.
t� 12.
Fees of $.................................. .
Impact fees as shown on attached schedule. .. .
California Department of Forestry plan approval/fees. ' . /at -
a -13.
13.
' 14.
Flood elevation letter (100 year flood) by California Engineer. . .
Sanitation and plot plan approval �fIAA✓�- SG Health Department . ............ l
15.
-
City of Chico plumbing permit . .........................................
16.
Plot plan and business license approval from City of Biggs/Gridley. .............
17.
Planning approval for (A) Use: (B) Parking: .........
18.
Contact Land Development about (A) Improvements (B) Drainage. .......... .
19.
Driveway permit (construction approval required prior to occupancy). .. .
20.
Pre -inspection for required. .. o e�,a 9 �speao (Date)
21.
Contractor's license information. (No., Name Style, Classification) . ..............
22.
Certificate of Workmans Compensation Insurance . ..........................
23.
Owner -Builder Verification (Given to owner , Mail to owner
24.
Recorded copy of Agricultural Acknowledgement Statement. ..................
25.
Letter of signature authorization . ................... i�' .
26.
Copy of recorded deed of parcel creation and 60 right of way to a public road. .... .
27.
Letter of intent on building use . .........................................
28.
Mobilehome utility clearance. ....................................
29.
Documentation of legal access . .......................1 ..................
30.
&Exi:
Documentation of 50% subdivision developed or (A) Road improvements completed
nd (B) Parcel meets zoning area and frontgf}e requir ments. ... .........
ting violations/expired permits. ........... .
A 32.
Plan checklist . ......................
33.
34
When you issue the .permit, process as follows: Mail to owner. Mail to contractor.
I elephone =-(, R*Aand hold for pickup at office. Deliver with inspector.
Parcel Creation
Acreage
Applicant
6,57" M_ Date //2,
Copy of Haz-Mat form sent .-Health Dept. Fire Dept. Air Pollution Date
\Copy of plans sent Health Dept. Fire Dept. Other Date By
The following data must be submitt
1. Index permit .for above items No.
2. Additional items required:
to permit issuance: (Circle new item not checked above).
Contract, designer, owner, was advised of above required data by pone _mail Counter byG Date
Contra or, designer, owner, was advised of above required data by phone _ mail ounter by Date Z4. 3
Plans checked by 60 Datelz41&3 _ Plans approved by Date/ /z
Sets of plans on hold in File cabinet AP folder
Copy - Department of Public Works
��
�� i
� � !,
z
COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION
7 COUNTY CENTER DRIVE, OROVILLE CA 95965 - TELEPHONE (916) 538-7541
OWNER �SAVVJ 1`l l `� A.P. #
PROPOSED BUILDING USEDATE
REC. # - DATE REC
1. SCHOOL DISTRICT FEES
(paid at District Office). ......................
2. SHERIFF FEES
(paid at Building Department)
Residential...... x =$
unit amt.
Commercial (sqft) x =$
sq.ft. amt.
3. URBAN AREA FEES
(paid at Building Department)
3
Residential (per unit) x =$
# units amt.
.Commercial (per sq.ft) x =$
sq.ft-. amt.
4. RECREATION DISTRICT FEES
(paid at District Office)......... ..............
5. DRAINAGE DISTRICT FEES
(Contact Land Development Division) ..............
6. SRA FIRE INSPECTION AND PLAN CHECK. = $89.00......
(paid at Building Department)
7. OTHER
IA -11-55
1x187'79
9a.�g
At time of permit application, I was advised the above fees are required to.be paid
prior to issuance of the permit.
APPLICANT
DATE
`COUNTY OF BUTTE
BUILDING DIVISION
DEPARTMENT OAF DEVELOPMENT SERVICES
;1469 Humboldt Road, Chico, CA - (916) 891-2751
7 County Center Drive, Oroville, CA - (916) 538-7541
747 Elliott Road, Paradise, CA - (916) 872-6307
CORRECTION NOTICE
}
d >�
PERMIT NO. _
A routine inspection indicates that the following violations of Butte County Ordinances exist at
the above address and should be corrected. Please notify this office when correction of work
is completed. If you have any questions pertaining to this matter, or need additional explanation,
please contact this office immediately.
Wt ilL t , °2. j
Wilp
Date Inspector
REV 10/92
I t
W;c
N
cDi
J,
+
... . ................
� 1 ! 2i I 2Z;t I!
7'
1 (dolma. VJOIA
qj
REVIEWED PY
BLTTE.CO FIR -E QEPT.
L (c.
CAU1 DEO.
j. .of FO ESTRY
—T
app .... ..
fi �, - : — -' -�. j i °Pr Wed as sub
tPi,ted
C
8
AL
L
appr
r,
a .01
ed with c�tdifronsppr)v14XZ6 p raepera lached shes'.
tur
Signa e
Date
z
7 It
Signature C',
D te
ALL STRUCTURES AND EQUIPMENT INCLUDINGM�q/)0//'
OVERHANGS SHALL BE CLEAR OF ALL EASEMENTS.
A SET BACK OFe�Ldih�. FROM THE SIDE AND
a,j AVh% FT. MOM THE REAR PROPERTY LINES AND
-5;_0 FT. FROM THE ROAD CENTE9'L1NESHALL,BE
CLEAR OF STRUCTURES AND EQUIPMENT EXCEPT
FOR A 2 Fr. EAVE OVERHANG.
go
I . ,
P/0
Uj I La nova
Lf 7 1'o I
CDF FIRE SAFE REQUIREMENTS
`33 -3 /90 SLCIfAJo%
AP # PERMIT # NAME
Under authority of PRC 4290, the following checked items are required
by the Butte County Fire Department and are made a part of this
permit. These requirements are minimums and will be superseded by
Butte County local regulations which equal or exceed these standards.
Field inspections will be made by the Butte County Building Department
for compliance.
V] 1272.00 Maintenance of Defensible Space. To ensure continued
maintenance of properties in conformance with these
standards and measures and to assure continued avail-
ability, access and utilization of the defensible space
provided for in these standards, annual maintenance must
be provided for by the land owner.
Driveway Standards
[ ] 1273.02 Surface. All driveway surfaces and structures (bridges,
1273.07 culverts and other appurtenant structures which supple-
ment the roadway bem.or:shoulders) shall provide unob-
structed access" ., t,:.:::,conventional drive vehicles, includ-
ing sedans and fire apparatus weighing up to 40,000
pounds.
[ ] 1273.03 Grade. Not to exceed 16 percent unless paved.
1273.04 Driveway Radius.
[ ] 1. No roadway shall have a horizontal inside radius of
curvature of less than 50 feet and additional sur-
face width of 4 feet shall be added to curves of 50-
100 feet radius; 2 feet to those from 100-200 feet.
[ ] 2. The length of vertical curves in roadways exclusive
of gutters, ditc!::es and drainage structures designed
to hold or divert water shall be not less than 100
feet.
[ ] 1273.05 Turnarounds. If required, will have a minimum turning
radius of 40 feet from center. of the road.
[ ] 1273.06 Turnouts. Shall be a minimum of 10 feet wide and 30
. feet long with a minimum 25 foot taper on each end.
[ ] 1270.10 Width. All driveways shall provide a minimum 10 foot
traffic lane and unobstructed vertical clearance of 15
feet along its entire length.
Page .1 of 3 BUTTE COUNTY
FMI DINc� nF. PARTMEW
AP #
PERMIT #
l/�� �•�-�/yl/.9� 6 Sim
NAME
[ ] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but
less than 800 feet in length, shall provide a turnout
near the midpoint of the driveway. Where a driveway
exceeds 800 feet, turnouts shall be provided no more
than 400 feet apart..
[ ] 1273.10 Turnaround. A turnaround shall be provided at all
building sites on driveways over 300 feet in length and
shall be within 50 feet of the building.
1273.11 Gates
[ ] 1. Gate entrances shall be at least two feet wider than
the roadway it serves.
[ ) 2. The gates must be located at least 30 feet from the
roadway and shall open to allow a vehicle to stop
without obstructing traffic on that roadway.
[ ] 3. Where a one-way .road with a single traffic lane
provides entran:e;-a 50 foot turning radius shall be
used.
Fuel Modification
1276.01 Setback for Structure Defensible Space.
1. All parcels 1 acre and larger shall provide a mini-
mum 30 foot setback for buildings and accessory
buildings from all property lines and/or the center
of the road.
] 2. For parcels less than 1 acre, local jurisdiction
shall provide for the same practical effect. See
Other Requirements below.
[�] 1276.02 Disposal of Vegetation and Fuels. Disposal, including
chipping, burying, burning or removal to a landfill site
approved by the loyal jurisdiction, of flammable
vegetation and {aiel caused by site development and
construction, road -and driveway construction and fuel
modification shad 'be completed prior to completion of
road construction or final inspection of a building
permit.
Page 2 of 3
BUTTE COUNTY
BUILDING DEP STMEW
APPROVED
Co S� 2, — l '?-- Cf 3 90 l/ lLLfji✓Ol��
r
AP # PERMIT # NAME
Other Requirements
[ ] If Building Setback is 15 to 30 Feet:
Class A or B roof
Enclosed eaves
[ ) If Building Setback is Less Than 15 Feet
Choose any 3 of the following:
- Metal doors on side toward property line with insufficient
setback
- Class A or B roof with enclosed eaves
- Interior automatic sprinkler system per NFPA 13D
Glass area not to exceed 100 of wall area toward property
line with insufficient setback
- Siding from the following list:
Stucco - 3 coat
Hardi-Board or Plank
Masonry
Masonry veneer
Metal
Other Butte County Fire Department approved materials
Date Signature
BUTTE CQUN i Y
BUILDING DEPARTMEN 1 .
APPROVED
1V� {1 •V i> (V VV11 V(VW �!(V1J �I (Yl( AVY W((V((V(VJ.
1/2"X 418' plywood sheathing
4
l
X4%4 bracing
4%4.dou gfir..posts_�
4"% 14'% 16' concrete slab
with wire mesh..
undisturbed earth
C14'=0"
90# roll roofing with 154' felt
5" rain gutter
Date
Sam & Jackie Villanova IDDM'(Co 36=TMM C®wtmcd®ffi CO -
Scale; 1 /4" =1' P.O. Box 1251, Paradise, Ca. 95967
14791 Magnolia Phone (916) 877-6886
Magalia, CA 95954 General Building Contractor
License Number 577983
FOUNDATION LIGHTING BUILT-INS FIREPLACE__ ROOM AND FINISH DETAIL
Concrete -Raised Few fair Kitchen Fon
---..—._..— Locat{om Room Floors Wollr
Ceilings
Concrete-L.�w Avg. Av Hood'- -
- . ..
_ g• Mefol Slone 6torY I 2 B CO. Nw. lino. S. R. Pi. Pan. S. R. PI. Acc. Ea. pm.
Conveto Slab - ------
----r---i ..l
Piers - •.. .. DF - .' ..� . I, Entry -- '---- — --
--- -J 11 1►V'S'� living _' __ --- -'-- ---- -•-- -.
jhn
- -- ----
BONE _STRUC / S —
���- I TI - --
Wd. Fr. C. P.I --- — -------
Brick Adob —
.—.— Steel Conc:EXTERIORStucco Panel
Siding Shing f Ir _ _ KITCHEN DETAIL
Shake Alum r ' L Cabinets
H. W. O.P. PI wd. Metol
L Y Nat. Stained
B b B Alum i Dr. Bd. b Cob. Top Tile Mico lino. $plash k_S_8peTCC_
� �G A F P
Br. Ven . Stone
Adobe 'f{•� • ' -'`P BATH DETAIL
1:. hdF {�. Iretrla lenlrat oes1. _t port.
Finish Fuluret _ Shower
C. -Bik Evnp. Roof Desk _ Electricity Fir, No. Floor Walls Toil. Lov. Tub St. O.i. G.D. Finish Pullman Misc.
Engrd. Wall ' O. H. doorlsl
WINDOWS Econo. Wind. Remote Control Dr.
• D. H. Wood
Finished
Csmf. Steel
Wr. Hir, Gals,
Finished
Sliders - Alum.
MISCELLANEOUS S'
tris. Leaded
APPRAISER &
DATE:
Crank Operated
Item
Fdtn. Flr
Ext. Int. Roof
Age Sire
S S. F.
JW
jig OAO
!; Gd
RCLND S S. F.
••• Gd. RCINO
S S.F •; Gd. itClNO
Sliding Gloss Dr(s)
-�_
-__ ROOF
BbCr1
1 •
Siu.!5
I
'
S 8 U
—Gable
Dutch Gable
— �
A
'1�-
pi Fit �-CF
Earl L�. .t
/�7
✓•� '
UA
! ,
-7000
Hip
_
-.
Shed
l Item
_
Fdrn. flr.
-'--- ...... ...... ._--' I—T^
E.r, tnt. Raol
Aq! •Sire
S. S.F.
�; Gd.
I A"51 0
RCLNO S S. F.
•� Gd. RCIND
Flat
S S.F. !; Gd. RCLNO
Mansard
Cut -Up
. Fin. Eaves
Shingle
'
Shake
Compo -Shingle
--
Compo-RollTarandGravel
A 1O•A4Tile
g4.
�Gultrn
1(�v
6 Dr! Sot,
J
COUNTY OF BUTTE — DEPARTMENT OF PUBLIC WORKS
BUILDING INSPECTION RECORD
Reinf. Steel Final I I Fixtures 1
Bond Beam FIRE SPRINKLERS I Motors
Mesh
MECOANICAL
BUILDING
BUILDING (Cont'd)
PLUMBING
Setback
Firewall
Soil Pipin
Forms
Parapets
1st Floor
Main Bldg.
Restroom Finish
2nd Floor
Footings
Windows
3rd Floor
Stemwall
Siding _0A
To out
Slab
Roof Sheathing 0
Water Piping
Piers
Roofing — /�� �,�
Sewer
Garage ~
Fdn. Vents
Fixtures
Footings
StemwaI I
Garage Vents
Insulation
Water Htr.
Heaters
Slab
Carport
p
Footings
Prov. for phsically
handica el
Conformance of ex.
structure
Appliances
Gas PI in & Test
Temp. Gas
Slab
_
Final
Sanitation
Patio
Footings/ t "
FIREPLACE
Footing
Final
ELECT ICAL
use......, w..u..
__ .
–
Reinf. Steel Final I I Fixtures 1
Bond Beam FIRE SPRINKLERS I Motors
Mesh
MECOANICAL
Scratch
Heating
Brown
Cooling '
Finish
Ducts
Interior Lath
Ventilation
Door Closer
Final
MOBILEHOME UTILITIES
------------------ Elec. Service
Grd. Fa
Temp. Pole
Undergroun
Permanent
Final
Elec. Pedestal
A
Water Piping Sewer Gas Piping
MOBILEH IME INSTALLATION - - - - - - - - - - - - - - Support Elec. Continuity
Water Piping Drainage Gas Piping
DATE REMARKS OR CORRECTIONS
/2���y
• (� CLc, � - CCS / � 6aS
.. _ I?aai' lltv7s -lb' 59• bw
��/�u•+2u uioJ> >vcrrd Yl.w 44w,cA1 Ad114
c�srs ®,t/ ��. fid, 4-iL� rl �'��� , Z�/
41—
Ole "440;' S 02_ t Y --T o 110110.S/�Arccf o4,c
� r /4'
� U
(NOTE: An entry must be made on this form each time you visit the job site.)
; j, .
1
«l
PERMIT
6626-79B
NO.
PERMIT EXPIRES
Frank Schwander''t
OWNER
y CONTR.
owner
65-29-12
LOCATION (A.P. )
f
23 Magnolia Way, lot 31, SD0gt1, Magalia
AI
1
S{
.x
ac.
v .f
II
!
i
4
orrf
l�
1
+
Temp. Power Pole
4t
Called PGE
3i
�&
Temp. Elec.lServ.
CalledPG&E
3i
Temp. yGas Serv.
Called PG&E
V
eo
FrNALED "
�
t
(D e)
(Si ature)
FJ
COUNTY OF BUTTE •-- DEP.ARTMENT OF PUBLIC WORKS
7 County Center Drive — Oroville, California 95965
Telephone: 534-4541 /n�/����� 7"
APPLICATION AND PERMIT Cl/n
-UU IUI ICG ICFlICJCIIIQIIVCA UI UIC VUUnIy UI OUtte 1U enter upon ine
above-mentioned property for inspection purposes.
'0t:1jg / 'If
Signature o ermltee or Agent
Receipt No. —3 o ) 0
White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTOR OF PUBLIC WORKS
By Date
uilding permit expires Date
03
BUILDING IV I
Owner. _
Iry
SO. FT. OCC. BUILDING VAL ATION`
72q!Y. Oro
Mailing Address � (��
i
Telephone No.
Contractor
Mailing Address
Fireplace
Total Valuation
Telephone No.
Permit Fee , ®>b
Building Address ����
Plan Checking Fee&/or Penalty
Permit Fee ,Q0
PLUMBING No.1 @ FEE
PERMIT FILING FEE J$3.00
Each Trap 1,50
Repair drainage or vent piping 1.50
A. P. No. ._ ���
nin i3 Planning
Water piping 1.50
Each gas water heater or vent 1.50
s
Fire Dept.
Fire Zone
Use Permit
Gas piping system 1 - 5 outlets 1.50
EOA
Parking
Plans
arcel
Declaration
Parcel Map
60' R/W
Improvements
Each additional outlet .30
uilding sewer 5.00
Bldg. P ans Recd
Parcel A royal
Plans Approval
Lawn sprinkler system 2.00
NEW ADDITION ❑ UTILITIES ❑ OTHER ❑
Permit Fee $
$
ELECTRICAL No. @ FEE
PERMIT FILING FEE $3.00
600V OR LE
Main service SS
10o AMP LESS 5.00
Single Family ❑ Duplex Mobil Home Others
❑ ❑
-L
Main service EA. ADD100 AMP 2.50
rnJE
'
Main service OVER so0vPOR LESS 25.00
100 AM
Main service/ EA. ADD'L 100 AMP 1.00
NEW
OR ADDNST ( ACCDWELBLOGS.LING CCUP. 4\ 22sgft
/
CONTRACTORS LICENSE LAW
'
I am licensed under the provisions of Chapter 9, Div. 3, of the
State of California Business & Professions Code under the name
st le of:
y
NEW RESID_ BRANCH CIRCUITS)
NON.CONST ( BRANCH CIRCUITS) 2.50ea
NEW CONSTR. (POWER APPARATUS 6
NON.RESID. SINGLE OUTLET CIR.
Ex. Occup(OUTLETS OR FIXTIIRES) g L 0)
Ex. OCCU / FIXED APPLNS. OR
p•\OUTLETS (RESID,) EA) 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
License No. Classification
Misc. Wiring 6.25
NJI am exempt from the Contractors License Laws of the State of California.
Permit Fee $
$
WORKMEN'S COMPENSATION INSURANCE
1 am aware of the provisions of Section3700 of the California Labor
Code which requires every employer to be insured against liability
for Workmen's Compensation.
❑1 have placed on file with the County of Butte a certificate of
Workmen's Compensation Insurance.
r 171 1 certify that in the performance of the work for which this
J�J permit is issued I shall not employ any person in any manner
so as to become subject to the Workmen's Compensation Laws of
California.
MECHANICAL iNo. @ FEEPERMIT
FILING FEE $3.00
Heating
Cooling
Ventilation
Hood 1 1 2.00
Permit Fee $
$
1 certify that I have read this application and state that the above
information is correct. I agree to comply to all County Ordinances
and State Laws relating to building construction, and hereby
I Land Development Fee
$
TOTAL PERMIT FEE$
-UU IUI ICG ICFlICJCIIIQIIVCA UI UIC VUUnIy UI OUtte 1U enter upon ine
above-mentioned property for inspection purposes.
'0t:1jg / 'If
Signature o ermltee or Agent
Receipt No. —3 o ) 0
White-D.P.W. — Yellow -Assessor — Pink -Inspector — Goldenrod -Applicant
This permit is hereby issued under the applicable provisions of
the Butte County Code and/or resolutions to do work indicated
above for which fees have been paid.
DIRECTOR OF PUBLIC WORKS
By Date
uilding permit expires Date