Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
065-380-007
BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAX#: (530)538-2140 WEBSITE: www.buttecounty.netldds PERMIT NO. BP061818 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 08/15/2006 APN: 065-380-007-000 the Business and Professions Code, and my license is in full force and effect. License Class: License Number: Site Address: 14713 DURAMEN CT MAG Date: Contractor. Map Index: Description: deck (360) OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a. permit to construct, alter, improve, demolish, or repair any structure, prior Owner: KEMP LYNN B JR & MARY F to its issuance, also requires the applicant for such permit to file a P O BOX 753 signed statement that he or she is licensed pursuant to the provisions of MAGALIA, CA the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or 95954-0753 she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): ZI, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Applicant: KEMP LYNN B JR & MARY F Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does P O BOX 753 such work himself or herself or through his or her own employees, MAGALIA, CA provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one 95954-0753 year of completion, the owner -builder will have the burden of (530) 873-0914 proving that he or she did not build or improve for the purpose of sale.). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does Contractor: not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I am Exempt under Article 3 of the Business and Professions Code Date: Owner: __4 License #: WORKERS' COMPENSATION DECLARA ION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Architect: is issued. ❑ Engineer: I have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Total Square Ft: 360 S.F. Policy #: Valuation: $3,600.00 Census Code: I certify that in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as to become subject to the workers' compensation laws of California,�� and agree that if I should become subject to the workers' r compensation provisions of Section 3700 of the Labor Code, I shall�� `J fortth�with comply with those provisions. � Date: —v� �[ Nl j r-,)—(: 76 (0 Applicant: q0. a f� WARNING: Failure to secure wor ers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one ffJJ ((��llUD hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor o 111) code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY This permit is hereby issued under the applicable provisions of the Motto County Coda anrvor I hereby affirm that there is a construction lending agency for the ResoluIioft to do work indicat dab ve for which fees have been paid. performance of the work for which this permit is issued (Sec 3097 Civ.) C Name: BY Date: J PERMIT XPIRES ON: 15011 (Date) Address: ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. 1 hereby authorize representatives of Butte County to enter upon the above mentioned property for inspection purpo s. • Print Name: /b V/ 4— Signature: Date: V �— L�7 0wrier ❑ Contractor 0 Agent for Owner 0 Agent for Contractor BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS 24 HOUR INSPECTION#: OROVILLE: (530) 538-7636 • CHICO: (530) 891-2834 OFFICE #: (530) 538-7541 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds **PLEASE PRINT CLEARLY** ) OWNER INFORMATION Last Name �� o. Address irstame Address A3 Or e (!!7– City m .. State cf�Zip Fax Phone^� Fax E-mail,^,11 VA �2 &t + L) ) APPLICANT INFORMATION CONTRACTOR Name U C Address J e City Fax State Zip Phone _ Fax E-mail Lic. # Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name City Address Zip City Fax State Zip Phone Date Approved: Fax E-mail State License Number APPLICANT INFORMATION Name e. Address C C� City State C Zip Phone_Gq Fax E-mail APPLICANT SIGNATURE tv X For office use only: Zoning Flood Zone SRA I Yes No Occ. Type Const. Subdivision Name Map Book Page Lot # Planner Date Approved: OVER FOR SUBMITTAL REQUIREMENTS K:\FORMS\BUILDING FORMS\BldgApplSubRgmts.doc PERMIT NO. W3 BIN # PROJECT LOCATION AP# �1 �+� 0 F5-0 r- 0V --000 Property A dress v G City I, 1 Cross Street WORKER'S COMPENSA ION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. Sheriff SMIP LENDING AGENCY }— Name we'\\6 rc�$' Address p 6. escription or Scope of Work: Sq FT- Living Garage Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Page 1 07,d Ktv t5-1 Z-uo Received by: Amount: (y";*7 Bldg SRA Receipt #- 1 Sheriff SMIP Date: /� Other � Total Page 1 07,d Ktv t5-1 Z-uo SUBMITTAL & PERMIT REQUIREMENTS The following drawings and specifications must be submitted to the Building Division in order to apply for a permit. INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. ALL PLANS MUST BE LEGIBLE AND IN INK. ❑ 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. No graph paper! ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans (No graph paper!) OR Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 3. Engineered truss details and layouts in duplicate (if required). No faxesl ❑ 4. Energy compliance design and supporting documentation in duplicate. ❑ 5. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 6. Manufactured homes: (A) Installation manual, (B) Marriage line info, (C) Floor Plan, j(D) Tie down or fnd plans, all in duplicate , ❑ 7. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. 'All of these must be stamped and wet -signed by the engineer. ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate (if required). ❑ 9. Site plan and business license approval from the City of Biggs. ❑ 10. Letter of intent for non-residential buildings. ❑ 11. Building Permit Application Without Required Clearances Form ❑ 12. Hazardous Material Form (for Commercial Buildings only). Remaining items needed to issue the permit. Additional items may be required after Plan Check and Planning review (May require additional plan review upon receipt of the following items.) I r ❑ 1. Agricultural Buffer clearance and site plan approval from the Ag Commissioner's office (if required). ❑ 2. Impact Fees. ❑ 3. California Department of Forestry plan approval (if required). ❑ 4. NPDES Form. ❑ 5. Encroachment Permit for driveway from the Public Works Dept. (construction approval prior to occupancy). ❑ 6. Contractor's license information. (Number, Name Style, Classification). ❑ 7. Worker's Compensation Carrier and Policy Number. ❑ 8. Owner -Builder Verification (if required). ❑ 9. Letter of Signature authorization (if required), ❑ 10. Recorded copy of Agricultural Acknowledgment Statement. ❑ 11. ❑ Legal description from current recorded grant deed, ❑ Copy of M.H. Title, Title transfer, or MCO. ❑ 12. Sanitation and site plan approval from the Environmental Health Department. If you have questions or would like additional information regarding this process, please contact a Permit Assistant at (530) 538-7541. EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after date of application. In order to renew action on an application after expiration, a new application, plans and fees will be required. REQUEST FOR FEE REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made within two years from the date of fee payment on permits not issued, and two years from the date of permit issuance for permits issued; however, on issued permits refunds can only be made if no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. OVER FOR BUILDING PERMIT APPLICATION K WORMS\BUILDING F0RMS\B1dgApp1SubRgmts.doc Page 2 of 2 REV 8-12-05 COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING D/V/31 * � P 1 v 7 County Center Drive, Oroville, CA .95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: /zfL'1 P ASSESSOR PARCEL NUMBER Proposed Building Use:L�G/L Permit Technician: Date: Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. Engineered truss details and layouts in duplicate. No faxesl ❑ 5. Letter from Engineer or Architect for truss design review. ❑ 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Installation manual, including marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate. \ ❑ 11. Hazardous Material Form 7rJ 12. Acknowledgement of building permit application without required clearances. ❑ 13. Other Wemml ems needed to issue the permit. (May require additional plan review upon receipt of the following items.) Sanitation and site plan approval from the Environmental Health Department in ❑ Chico ❑ Oroville, as applicable ❑ 15. Fire Sprinklers............................................................................................ ❑ 16. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 17. Soils Report and/or Engineered Foundation required ........................................... �18 Erosion Control Plan Required .......................................... ............. ..... - 9 ees as shown on the attached Schedule of Fees Due Sheet !�...�m3� .............. ❑ 20. City of Chico Plumbing permit........................................................................ ❑ 21. Site plan and business license approval from the City of Biggs .............................. \ ❑ 22. California Department of Forestry plan approval ❑paid. Sent by: ........... 3. Planning approval for (A) Use: OL- (B) Parking: (C) Parcel Check:....✓........ d 0 Contact Land Development about _ Improvements, _ Drainage........ ................ ❑ 25. Fire Marshall Review (commercial projects only). Sent by: ...................... //V 26. NPDES Form............................................................................................. ❑ 27. Encroachment Permit for driveway from the Public Works Dept ........................... ❑28. Contractor's license information. (Number, Name Style, Classification) ................... C3 29. Worker's Compensation Carrier and Policy Number .......................................... / 30. Owner -Builder Verification ( _ Given to owner, _Mailed to owner) ..................... ❑ 31. Letter of Signature authorization.................................................................... ❑ 32. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 33. Existing violations and/or expired permits......................................................... ❑ 34. Deed Restriction.......................................................................................... ❑ 35. ❑ Legal description, ❑ M.H. Title, title search, registration or MCO ......................... ❑ 36. Other: ❑ 37. Other: When issued Telephone V /N/� 673-05W and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: c Date: 1. Index permit app icatio foM u Plan Check Letter 2. Additional items required Contractor, designer, neata by phone, ❑ mail, ❑ counter, by Date: Contractor, designer, o , was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the abo a data by ❑ phone, ❑ mail, ❑ counter, by Date: Plans reviewed by: 4 4e Date:-H-LOA6 Plans approved by: Date: ZO Structural reviewe y: Date: Structural approved by:. P Date: Note transfer by: Date: ` �� Yellow: Building DiSisi �P PRTMENT 6UTT� I' 0 �� COUNT, °A-�� Department of Public Works 00 `j C o u m y o f B u t t e p IJ LAND DEVELOPMENT DIVISION / J. Michael Crump, o�� Director Storm Water Management Program 7 County Center Drive Oroville, CA 95965 iOve�� W OV01�5 (530) 538-7266 (FAX) 538-7171 National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement [LESS THAN 1 ACRE] Project Description: Project Location and/or Parcel Number: By signing below, I, the project owner/owner's agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I, therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site build -outs of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. I am aware .that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions provided by law. Signed: =6.*— -M 4V ,'an. Title: // Date: _ �� C) (O Less than 1 Acre NPDES & S WPPP Compliance Certification Butte County Storm Water Management Program - Revised 5/24/04 Butte County Department of Development Set -vices ADMINISTRATION ` BUILDING t GIS ` PLANNING 7 County Center Drive Oroville, CA 95965 (530) 538-7541 Telephone (530) 538-2140 Facsimile OWNER -BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit_ Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and. bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that your plan to subcontract, you should be aware of the following information for your benefit and protection: o If you employ or otherwise engage any persons other than your immediate family, and the work (including materials and other costs) is $200 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. o If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment compensation contributions. o There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. o For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally orthrough their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractor is to secure an "owner -builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification from so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned. Sincerely, Scott Rutherford Chief Building Inspector NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. le OWNER -BUILDER VERIFICATION TION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and_return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. 1. I personally plan to provide the ��or labor and material for construction of this proposed property im ovement YES.[ V/1 NO[ .1. - 2. I HAVE [ V . J HANE NOT [ ] signed an application for a building permit for the proposed work. 3. I have -contracted with the following person (firm) to provide the proposed construction: NAME: ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise, and- provide the major work: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: PROPERTY OWNER - n � (� <e -_ DATE: 0� NOTE: This Owner -Builder verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the Butte CountilDeparLmentofDeVelop-MentSerylees o$UTr�.o 7 County Center Drive t. Oroville, CA 95965 (530)538-7601 Telephone (530)538-7785 Facsimile BUILDING PERNUT APPLICATION WITHOUT REQUIRED CLEARANCES 1 request and authorize the Building Division to process this building permit application through the plans examination process WITHOUT first obtaining all necessary, related permits and clearances from other regulatory entities, including but not limited to, Planning, Environmental Health, Land Development, County Fire, and Agriculture. I hereby acknowledgd: I need to submit applications for septic andlor well to Butte County Environmental Health immediately. I am required to bring the approved Environmental Health site plan and approved sanitation clearance to the Building Division as soon as clearance is obtained I am responsible for notifying Development Services, in writing, to stop processing of the application and to arrange for disposition of p1ans. The Building Division will process the application through the plans examination process, as submitted, without input from other regulatory entities that could prohibit issuance of the building permit or require submission of amended building plans to the Building Division. Once the plans examination process begins, there will be no refund of plans examination fees. Any changes requiring submission of amended plans to the Building Division will incur additional fees. Within one year from the date of application for a building permit, all other required permits and clearances from other entities must be obtained for the permit to be issued. Failure to obtain these permits/clearances will void the application. Typically other required permits/clearances include, but are not .limited to, verification the parcel was legally created, adherence.to all mitigations and conditions imposed on the parcel at time of creation, as well as zoning requirements, legal access, and applicable set -backs and environmental issues (fire, agriculture buffer zones, and habitat/species). , Please print: Applicant Name: 1 f lV e--Cn Building site address: ),�9 B APN:��C�._ C� Permit No.: I have read, understood and accept the terns and conditions as expressed herein as indicated by my submission of the above -referenced building permit application and my signature below: ' r SIGNATURE F APPLICANT DATE r Copy to Applicant/EH/File K Forms/BldgPermitwithoutClearances 020705 f4' VARIES _ 36' Mil Ph 17- -T) -- 17 op ® o� O6—tB�S r lUTTE COUNTY BUILDING DIVISION rn X E APPROVED fl � ec alac�C N . LA to r •.. ' - 0 ' M L n ¢- o a 3 6Y mim STAIR �; u Cit 4 MI. A ` � C J-, 3 tQ 9 •. A rt - _- I99S 65 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 www.buttecounty.net/dds PHONE (530) 538-7541 FAX 538-2140 RECEIPT OF FEES SCHEDULE - RESIDENTIAL Owner kemp APN No: 65-380-007 Permit Type: F----T'-]Subtype: App Date: 7/28/2006 Permit No: BP 06 1818 Permit Desc: 1 BUILDING PERMIT FEES ESTIMATED AT APPLICATION $150.00 Plan Check portion of Permit Fee $60.00 $90.00 Balance of Building Permit Fee 2 FEMA RYes Yes Flood Elevation Review $109.98 0 3 SRA* Fire Plan Check - Non -Refundable $95.00 0 (State Responsibility Area) Building Inspection $109.98 0 - $204.98 NON-REFUNDABLE portion of fees due at application $60.00 4 5 6 7 7a 8 FEES DUE AND PAYABLE AT TIME OF PERMIT APPLICATION FEES (BELOW) DUE PRIOR TO ISSUANCE OF PERMIT Balance of Building Permit Fees (from No. 1 above) SMTP* - Strong Motion Instrumentation Program (Enter amount from permit system) Additional Plan Check Fees (NON-REFUNDABLE) Other*: Other*: =S - RESIDENTIAL* I Per Dwelling Per Dwelling Per After 04/15106 at SFD # MFD ,c 4249.11 3183.54 MH 3238.72 5648.44 2422.68 8486.40 RECEIPT DATE Tech/Asst 6 i 7-2-8 �� O 7289.40 RECEIPT DATE Tech/Asst 0 $100.00 $200.00 10 10a 11 11a Chico Urban Area 6146.23 4538.82 771 Comanche Creek $8,341 EI Medio Fire District 3249.97 2385.76 774 Lindo Channel $8,267775 North Chico Specific Plan 776 Mud -Sycamore Creek $6,275 777 PV Ditch $8,893 More than 1 acre, existing buildings - fees to be assessed by Public Works Fee Determination Sheet Needed - Enter amount determined by PW A SR -1, SR -3, SR-1/PD 8801.091 7395.04 �c tR-1 � 8897.09 7491.04 do R-2 8390.09 6984.04 R-3 7604.091 6198.04 Processing Fee is automatically added to impact fee total 9 WATER TENDER FEE (Not collected when impact Fees Applicable) Enter Bat.# DRAINAGE FEES* MH 3238.72 5648.44 2422.68 8486.40 RECEIPT DATE Tech/Asst 6 i 7-2-8 �� O 7289.40 RECEIPT DATE Tech/Asst 0 $100.00 $200.00 10 10a 11 11a CHICO STORM DRAINAGE MASTER PLAN 770 Butte Creek $7,997 RECEIPT DATE Tech/Asst l�J 771 Comanche Creek $8,341 New construction, vacant land, on 1 acre or less - Enter 1 or less acre value 772 Little Chico Creek $9,088 773 Big Chico Creek $6,776 774 Lindo Channel $8,267775 SUDAD Ditch $7,211 776 Mud -Sycamore Creek $6,275 777 PV Ditch $8,893 More than 1 acre, existing buildings - fees to be assessed by Public Works Fee Determination Sheet Needed - Enter amount determined by PW THERMALITO DRAINAGE AREA 1 $684 Maximum Per each new living unit on existing lots where full drainage fees have not been paid Temporary Dwelling 1 $136 At time of building permit $136 annual renewal fee for first 4 renewals. Not to exceed $684. PROOF OF PAYMENT OF FEES (BELOW) MUST BE RECEIVED PRIOR TO ISSUANCE OF PERMIT. Forms will be prepared after plan check is completed for applicant to take to respective district office. 12 SCHOOL DISTRICT FEES* 12a RECREATION DISTRICT FEES* At the time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the plan checking process. Applicant:4==A)L4 Date: (c, Pursuant Pursuant to Government code Section 66020, you 04hefeby notified those Items followed by an "*" may have been imposed on your project. You have 90 days from the date of approval of the porject or from the impostion of the above referenced items during which you may protest. The requirements for a protest are specified in Goverment Code Section 66020(a). K:/Building/Forms/Schedule of Receipt Fees Residential 041506 RECORDING REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DMSION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 C09:3' ' of Document Recorded 09 -Dec -2003 2003-0085736 Has not been compared with original BUTTE COUNTY RECORDER SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBILEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. LYNN B. KEMP JR. AND MARY F. KEMP REAL PROPERTY OWNER/LESSOR 4183 SELMA AVENUE MAILING ADDRESS RIVERSIDE RIVERSIDE CA 92503 CITY COUNTY STATE ZIP 14713 DURAMEN COURT INSTALLATION MAILING ADDRESS, IF DIFFERENT MAGALIA BUTTE CA 95954 CITY COUNTY STATE ZIP SAME UNIT OWNER (if also property owner, write "SAME") SAME MAILING ADDRESS SAME CITY COUNTY STATE ZIP UNIT DESCRIPTION BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE BUTTE CA 95965 CITY COUNTY STATE ZIP 03-2834 530 538-7541 B G PERMIT N0. TELEPHONE ER sfiraNkTIVE"OF LOCAL AGEN CIAL DTE EXECUTIVE H S DEALER NAME (if not a dealer sale, write "NONE") 92081 DEALER LICENSE NO. FLEETWOOD HOMES 2003 SUNCREST 4513B MANUFACrUREWS NAME DATE OF MANUFACTURE MODEL NAMElN[IMBER CAFL317A/B27076-SC 13 51'X26'8" PFS0835286/7 SERIAL- NUMBER(S) LENGTH X WIDTH INSIGNIA/LABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER AP # 065-380-007 SEE ATTACHED HCD FORM 433(A) REV. 8/91 WHITE - County Recorder CANARY - HM PINK - Applicant GOLDENROD - Building Dept. 09:28 BIDWELL'TITLE � 530 891 8753 N0.451 P012 Preliminary Report Order.No. BU -201552-2 CH Description _.. The land referred to herein is situated in the State of California, County,.of $utte, and is 'des ' Mows: cubed as LOT 228, AS SHOWN ON THAT CERTAIN MAP"SIERRA . r NO. 3, WWCH MAP WAS RECORDED IN THE Op, oEL ORO ESTATES UNIT OF BUTTE, STATE OF CALIFp RDER OF THE COUNTY 28 AND 29. RNIA, ON 3LTNP 3, 1968, IN BOOK 35 OF MAF► A7- PAGE(S) 27, EXCEPMNG THEREFROM ALL OF THE VALUABLE MM THE SAID LAND WrM THE RIGHT 'PD MINE RAC BAW M THE SURFACE,ITBE OF AQREED UNDERSTOODAUNDERSTOODTHAT IN ALL MININGOPERATIOTVS, THESURFACE,F SAID , LAND WILL BE PROTECTS AGAINST DAMAGE AND THAT ALL SUCH CARRIED ON FROM TUNNELS, SHAFTS ORD SING SHALL BE THE SURFACE AREA OF T RIFTS HAVING THEIR ORIFICES OUTSIDE OF RESERVED IN THE DEED FROM MAGALIA MINING ED REALTY,NY, ALL AS EXCEPTED AND STOATS, ET UX, RECORDED S MII`nNG COMPANY, A CORPORATION, TO E. D. RECORDS, AT PAGE 385. fiPTEMBF� 4, 1947, IN BOOK 423 OF BUTTE COUNTYOFFICIAL i APN 065-380-007 000 .-.`.'G. ♦ �, �r wi- ,Yn �a4,y 1 .,- c a -c ,�, —«F C r- e. -�:: � —.- r�. �.�3,.��ab. 4 `�.i S .. ., p. u": aat- s._.�`' � �_ .•ti .,„d a� .A.0 t� y :t � � �i...e.. � sww,- ;��.s;.,�7, _�, 3ec r ` FOUNDATION S Y ; 'S STEIVI� CERTIFICATE OF-OCCYUPAN.CY { 4c BUILDING PERMIT NUMBER: 03-2834 Address or location of unit: 14713 DURAMEN COURT, MAGALIA CA 95954 Legal Description of Real Property: AP # 065-380-007 SEE ATTACHED (x) Mobilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: LYNN B. KEMP JR. AND MARY F. KEMP Owner's address: 4183 SELMA AVENUE, RIVERSIDE CA 92503 INSIGNIA OR HUD NUMBER: PFS0835286/7 SERIAL NUMBER OR V.I.N.: CAFL317A/B27076-SC13 MANUFACTURER'S NAME: FLEETWOOD HOMES YEAR: 20 OFFICIAL APPROVING INSTALLATION: DATE: PHONE: (530) 538-7541 H.C.D. 513C FILE No.726 11/20 '03 Aft 11:59 ID:EXECUTIVE HOMES FAX:530 891 8753 PAGE 1 71" /�'B.USINE88 TBANBATE O CALIFORNIA �c 1 66S -et 7]QKRI�.}(Gt7®WO:A09Nl;T.�- '• �_ ":.._V _ . _ - _ — - OP HOUSING AND'OOMMUNITYR EVe `� �d �d 7 -': D.IdiA IAIJFACO�DEBAN. DS—. 8 JURER .. CIEATEt ,. ourld�61�i'�II�C'"� .WEA!"• . •IX; +,...:.c:. .. . -.:.._ .. Y1a14f.lAaiP¢.wltiireu ir: � 4 (SINGLE FAMILY DW ni.:.:.:.:,r�..:T:'::;; ELLINOI MUMH (MULTI -UNIT MANUFACTURED HOU81Nq NUMBE/ OT .r,-,,: • • \ ,; r�;.......t;.. tRAN6.0on A :. r.' �..::....:...::." et:e'spc'rloN6 .. OCCUPANCY GROUP _MAN FACTIJR NAME; i� !327VOOD Homos or CALIFO IAf INC. MA UFACTUR R LICENSE UMBER: MAN C E 9534 1 q street LA SUGGESTED RETAI PRICE: M NUF TURER TRADE NAME=.: CII 81elej 80NCRSBT MOUE NA E ANDtOR NUMBER: AM D TE OF• 45138 MANUFAC7'UgE: 1 2004 11/12/2003 3�TNr� 411r=7HAN8FERREIJ TO Oft BXRCUTIVE AONB9 NC TA IF.DEALE NU ER R TRANSFEREE DE910NATION: D TE O T SFER: DEA ER OR TRANSFEREE ADDRESS: 92061 3042 ZBPLpNApg 11/14/9003 svCHICO INVENTORY C EDITOR NAME: CII CA 95973 Tf�dl:R 8AICA DISTRIBUTION FIN slate ZI INVENTO Y CREDITOR ADDRES F 0 BOX 94900 Street PA T.ATT(,T4 SECTION CII state IL 60094 1.9 MANUFACTUnF,.li SERIAL NUMBER ZI I ICL) INSIGNIA OR HUD LABEL NUMBFR 1 CAH'L317A97076- LENOrH WIDTH WEIOHI' 8013 INCHES INCHES POUNVO PFROB35206 . 2 CASL317827076-8C13 612 160 22,90 PF80835287 619 160 23,44 TRANSPORTER NAME: D i R TRANBPORT, INC. TRANSronTEn AODREa8: P.O. BOX 179 BUagt OF.STINA7'1ON FOR UNI7 DERCRIBED ABUVP. CII DURHAM Blaig 9 (ZIP) 3938 LF n lmder Cu + v Fgnaly or DeII.,Y unue. It q law. nl Ina Bute of C*loorrde 111311113 Ahov6 Inv' ewe .te e.e Iroe e..d coned. z ,.do� 11/12/2003 WOODLAND 1 ate) at YOLO cnY) CA ATURE Or AUTHORV, ICnumYl ED ADENT:J-1... . .....:twa' copyOnIUIIV PINK) FORWARD//LL11 711E INVENTORY Cn1:DrrOR, UNLESS TFIERQ IB NONE, THEN FURWMO TO THE rURCIfA R FA COPY 1 (MITE) FORWAROIJ COPY; (y LI.Oyy) 02LIVEn TOT HE-TnANS DEPARTMENT A'r P.O. BOX 1843, SACRAMENTO, CA 0!181 Z_te e, WITHIN FIVF, 13) GIN'S n R COPY 3(GOLOF.NR00 TOB AN9rOnIF.R TO ACCOMPANY:IMF. UNI'T.TO IIB OES88 TI BE 10- LER OR TMNSFEneF. ). IICD 46J.0. 81Ue 1 - (7/STI 1 E RETAINED BY THE MANUrACTUnSR, /) ON. PLEASE, STATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND IIOUSING AGENCY ��d41n10F DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMEN'r c� DI VISION OF CODES AND STANDARDS ' �' • REGISTRATION AND TITLING PROGRAM o s STATEMENT OF FACTS n Tllis unit is a XMobilchome ❑ Conunercial Coach ❑ ['loatulg ]Irnne ❑Truck Camper I Decal (License) No.(s) frnde Name Serial No.(s) ]/We, die undersigned, hereby state: The above described unit has been placed on an approved foundation system in accordance with 18551A of the Health and 5afety Code. I/We further agree to indemnify and save harmless the Director of Housing and Community Development, State of California, and subsequent purchasers of said unit, for at loss they may sutler resulting from registration of die above-described unit in California, or from issuance of a California certificate of title covering die same. I/We certify under penalty of perjury that the foregoing is true and correct. Executed on 0, %, oOQ � at Gil 171 (Date) (City) (Slate) Signature(s) keeell ' Address City IiCD 476.6 (REV 12/00) 3042 Esplanade Chico k Printed name(s) Susan Glatz Executive Homes State — CA TATE OF CALIFORNIA BUSINESS, TRANSPORTATION AND HOUSING AGENCY DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT � ~ DIVISION OF CODES AND STANDARDS REGISTRATION AND TITLING PROGRAM'"n STATEMENT OF FACTS This unit is a: U Mobilehome 0 Commercial Coach ID Floating Home 0 Truck Camper Decal (License) No.(s) Trade Name Serial No.(s) -T e� -----VW.e,-the..undersigned,._hereby_state: ®r 3 7W6 zv / /- "-- &-: 0.C) '4 We further agree to indemnify and save harmless the Director of Housing and Community Development, State of California, and subsequent purchasers of said unit, for any loss they may suffer resulting from registration of the above-described unit in California, or from issuance of a California certificate of title covering the same. I/We certify under penalty of pe=j Fxecutefl"on/ 0 at� ( ate) Signature(�,,/ � 7/ T -T .n 476.6 (R F.V 9/91) the foregoing is true and correct. (City) Print m (s) ( State . r, - 1;7) - (State) 09/09/03 08:29 BIDWELL TITLE 4 530 891 8753 PARC RECORDING REQUEB'Y'laD HY MID VALLEY TITLE Co. AND WMN RECORDED MAIL Tot MR. 3 NSSFZMALVRqTjE)�. KEMP, JR RIVERSIDE, CA 92503 A.P.N.: 065-3go.oU7 Order No. I REXfE� � 58 � TAX I I I I I Kathy I page i of 2 Above This Line for Recorder's Use Only Escrow No.: 201MCH GRANT DEED THB UNDERSIGNED ORANTOR(0 DECLAMa) THAT DOCUMENTARY TRANSFER TAX IS: COUNTY $27.50 X I computed on full value of property conveyed, or computed on full value less value of liens or encumbrances remaining at time of sale, X'1 unincorporated area; ( I Town of _, and FOR A VALUABLE CONSIDERATION, Receipt Of which is hereby acknowledged, MARIA JOAN G. WENZEL, 'TRUS'T'EE OF TRE MARIA JOAN G. WENZEL REVOCABLE LIVING TitUST hereby GRANT(S) to LYNN B. KEMP JR and ht&g ( F. REMP, Elusband and Wife as Joins Tenants the following described property in the trrV CORPORAT E;D AREA, County of BUT TE State of California; See Legal deguiption attached hereto and made a part bereop, G. N Ci. WENZEL. TRU, - M�M27 2002 STATE Orc COUNTY OP AS TRUST Peraoaalty al l mrd 1►IegR7A �7t3?W G bt fore me. CFiERI iiOVFY NO'TARX PUBLIC G. I� -w,, Ptm=lly knowo to me (or proved Co me 0n th bash of eatiaiactory evidence) to be the and ecicoowledged to me then he/she/ Pctson(e) whose neme(s) ia/aro eobacribed to tha wlWia 1110'"trYmetlt the P"800(s) or the Cxewhic tjh B e n ltiellterhheir authorized csPwity(les) and ftt by hib ajjhc4 8i �N �tr4+ aeon behalf of which t1,e persen(s) acted. 0xecutid the instrument. �atw�e(s) an �hjand/jand official BHn aal. Signawt��/ (f' /l .t . This area for official notarial Beal. C"Em OEM Rff kW 7 W113 ouyPubllc-Califotnla Buff sr.�aoa Mail Tax Statements to: SAME AS ABOVE or Address Noted 13 Clow a 09/09/03 08:29 BIDWELL TITLE 4 530 891 8753 Preliminary Report Description Order No. BU -201552-2 CH The land referred to herein is situated in the State of California, County of Butte, and is described as follows: LOT 228, AS SHOWN ON THAT CERTAIN MAP ENTITLED, "SIERRA DEL ORO ESTATES UNIT NO. 3", WHICH MAP WAS RECORDED IN THE OFFICE OF THE RECORDER OF THE COUNTY OF BU M, STATE OF CALIFORNIA, ON JUNE 3, 1968, IN BOOK 35 OF MAPS, AT PAGE(S) 27, 28 AND 29, EXCEPTING TFiEKEFROM ALL OF THE 'VALUABLE MINERALS BENEATH THE SURFACE OF THE SAID LAND WITH THE RIGHT TO MINE AND EXTRACT SAID MINERALS, T,T BEING AGREED AND UNDERSTOOD THAT IN ALL MINING OPERATIONS, THE SURFACE OF SAID LAND WILL BE PROTECTED AGAINST DAMAGE AND THAT ALL SUCH MINING SHALL BE CARRIED ON FROM TUNNELS, SKAFTS OR DRIFTS HAVING THEIR ORIFICES OUTSIDE OF THE SURFACE AREA OF THE ABOVE DESCRIBED REALTY, ALL AS EXCEPT O AND RESERVED IN THE DEED FROM MAGALIA MINING COMPANY, A CORPORATION, TO E, D. STORTS, FT UX, RECORDED SEPTEMBER 4, 1947, IN BOOK 423 OF BUTTE COUNTY OFFICIAL RECORDS, AT PAGE 385. APN 065-380.007-000 2439 SECURITY MOBILE HOME SHOW/NORTH, INC. EXECUTIVE HOMES 11-4288 oss 3042 ESPLANADE PH. 530-891-6992 �G _lj 1210 CHICO, CA 95973 DATE—,— PAY ATE A� PAY TO THE L !✓ ORDER OF �jQ LABS WeIIs Fargo ank N.A. i 0oCalifornia �.wellsfargo.com FOR 1120 2L,3901"+': L 2 10L, 2S8 21:0 0007G001,112 1 NAME: AP#: ' 6 [ - DATE: , A r_. 065-380-007 r 06-1818 or , KEMP,'LYNN - f. NOTES ,14713 DURAMEN CT, MAGALIA COW: OWNER . _ v °�� ' DECK • y _ RE5*1L) N rrAL APN: Permit No. Owner. Site Address: Contractor. r + Type of Permit: r i 1 s t - x 4 SRA FLOOD CERTIFICATE EQUIRED FIRE SPRINKLERS REQUIRED SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUBSTANDARD HOUSING LETTER ENCROACHMENT PERMIT REINSPECTION FEE PAID ENV HLTH CLEARANCE CHECKED BY • � Ort' ��SEcvc�o Fc rt �\ V �- DATE JOB FINALED: / r SIGNATURE: fl. z o=OK 0 = Not OK MANUFACTURED HOMES MISCELLANEOUS - DATE I Lj PERMANENT FOUNDATION Lj SOFT -SET 1 ZoningSetbacks-Easements 2 Soils; Special MH Support Sketch 3 Sewer; Loctn-Test; FalUC/0-Concrete 4 Wtr; Loctn-Test-Easeinent Needed -Regulator 5 Elec Loctn-Clmcs-Gmd 'Amp -Concrete 6 Yard Gas; Loctn-Test-Wrap - Nat ❑ or LP❑ Inch Sz Ft Lngth 7 Blckng; SzSpacing-Marriage Line 8 Gas; MH Test -Demand Valve-Dnnctr 9 Elec MH Cntnty Test-Crossovers-Breakers-DImcs 10 Drain; MH Test -Fall -Flex Cnnctr 11 Wtr & Sewer Connected -C/O to Grade 12 Gas and Electricity Tagged 13 Tie Downs ❑ Foundation ❑ 14 Exits 15 Cert of Occupancy 16 16 HUD Labelansignia Numbers Serial Numbers '---DATE D E C K S -C O V E R S•C A R P O R T S -G A R A G E S 1 Zoning -Setbacks -Easements 2 Ftg oilsSz-0pthSpacing-CnnctrsSteel , Girders/Jolsts-Dcking-Brcing Stairs-Guard/Handrails 4 Wood Awn; Posts-Beams-Rftrs-CnnctrsShthg. Frmg-Brcng 5 Alum Awn; Columns-CnnctnsSplice-Decal-Encisrs 6 Carports; Wndws-l)oors 7 Electric 8 Frrng; Sills-AnchrsStuds-Rftrs Trusses 9 Siding; Nailing -Veneer -Stucco -Lath 10 Roof; Shthg-Roofing 11 Ext; Steps -Doors -Landings 12 Braced Wali pnls � lr�� �y, i � 41 DATE IPOOLS 1 Setbacks -Easements 2 Soils; Compaction -Structure Stability 3 Pool Structure; Steel-Dnnctns-Thickness Dead Men -!.fining 4 Elec Rcptcls/Lting; Distance-GFI 5 Elec Pool Lting; 15 volts-GFI 6 EIec.Enclsrs; Conduit Entries -Terminals -1 -fisted 7Elec Bonding; Metal w/5'-Crcitng Egp-Htr 8 Elec Gmdng; Eqp w/5' Crcitng Eqp-Pool Ightg BoxerEncisrslboardsansultn to Main Conduit 9 Health Dept Appivl 10 Plmb; Cir Test Wtr Supply Test 11 Lt Niche , 12 Enclsr; Fencing -Alarms 13 Bonding, Diving board or Slide °r °�� ° Pool Drawing RESIDENTIAL (Single & Duplex) DATE JUNDERFLOOR DATE IPLUMBING 1 ZoningSetbacks-Easements-FloodSlope 53 Wtr Htr; Vent Acc-Cmbstn Air Baffle 2 Ftg Main; Soils-Elec Grnd Ftg Dpth 54 Wtr Pipe; Test & Anchr-Nail Prtctn 3 Ftg Garage; SoilsSteel-Elec Gmd Ftg Dpth 55 DWV; Test Fittings & Anchr Nail Prtctn 4 Ftg Porches/Decks; Soils -Steel Ftg Dpth 56 Shwr Pan; Test, First flr-Tub Acc 5 Stemwalls Main; Steel-Biockouts Wrapped 57 Test Tub" & Shwr, 2nd fir - Tub Acc 6 Stemwalls Garage; Steel-Blockouts Wrapped 58 Gas Pipe; Sz & Anchm ' 6a Hold Downs and Special Anchm 59 Fire Sprinkler; Test 7 Slab, Steel Wrapped 60 Yard Gas.Piping 8 Piers-Frpic Ftg-Steel 9 DWV; Fall -Fitting -Test -2 -way CIO -Sewer Test 10 UF, Gas Pipe; Sz AnchrsSz Test 4 11 Wtr Pipe; Test-Anchrs-RgltrService Test 12: Elec Undrgmd DATE IM E C H A N'l C A L 13 Plenums & Ducts; Clrnc-MaterialSupportdnsultn 61 AC Ducts Insultn & Support 14 GirdersSills-Anchr Bolts-Joists-Vnts-Cripples 62 Vent Fan, Exhaust abv Insultn 15 Acc & Vntltn 63 Condensate Drain & Ovrfiw, Sz & Grade 16 Insulation 64 Furnace Vent Acc-Comb Air Rtrn/Vent 115 Outlet 65 Attic Acc & Pltfrm if Furnace In attic m`411 DATE FRAMING 17 Sills Proper Materials & Anchm DATE IFINAL 18 Walls Studs -Nailing Spacing & Braces-PlatesSound66 Ext Steps -Door & SideLt Prtctn-Landings 19 Bearing Walls over Girders &flr Nailing 67 Smoke Detector 20 Draft Stop In Walls (rat proof) 68 Furnace Vnts-Cimc-Comb, Air-Cnnctr 21 Fire Stops; Furred Ceilings -Stairs -Chasers -Tubs In Garage; abv-flr-Ducts-Meth Prtctn 22 Headers & BeamsS &'Bearing" 69 Bedroom Exiting 23 Hangers -Post Caps-Anchrs-Cnnctns 70 GFl 8 Bath Fxtrs &Tub Acc-Spa 24 Ceiling Jopst-RW Ties-Purlin-Roof Brac TrussShthg 71 GFI Arc Fault 25 Frplc Ties or Type A Flu&Frolc Throat Cimc 72 Elec Trim & Subpnl, Breaker Szs & Labels 26 Attic Acc; Sz &Kiwi PRetn-Draft Stop -Ins Baffles 73 Stairs, GuardMandrails 27 Bdrm Wndws or Exiting Doors -Sill Ht & Dimensions 74 Frplc or Stove, Cimc-Hearth 28 Garage Fire Prtchi Framing -RC Channel 75 Elec Outlets at Wood Pnl, Int & Ext 29 Prprty Line Firewall & Opngs' 76 Ktchn, Fxtr & Appinc; Gmd Air -Gap -Cooking Cimc 30 Ext Doors -One 3' -Check Garage 3rd Story, 2 Exits 77 Elec Outlets & Rcptcls at Ktchn Counter 31 Stairs; Width-Hdrm-Rise-Run-Landing-Fire Prtctn 78 Garage Fire Door; Swing -Landing -Closure 32 Plywd on Roof Ovrhng Attic Vnts-RRr Outrgm 79 AC Duct in Garage -Damper. 33 Siding -Nailing Veneer 80 Wtr Htr; Vnts-Clmc-Com Air Cnnctr-PRY; abv fir 34 Stucco Lath -Weep Screed-Fndtn Vnts-Undrflr Acc Mech Prtctn; LPG Appince Undr House 3' drain 35 Glazing Are PrtctnSkyLts-Plastic . 81 Pimb; Elec & Mech Eqp Listed for Loctn 36 Shear Walls; Nailing -Bolts 82 Elec Rcptcls in Garage (GFI) Romex Prtctn 37 Brace Int/Ext Wall pnls 83 Insultn-Foam-Looked in Attic 38 Insuitn-Walls-Ceilings 84 Guard Rails & Deck Cnstrctn-Post Caps 39 Infiltration-Walls-Wndws 8$ Fndn Vnts & Crawl Hole Door Dmge & Wood -Earth 86 Cimc Dmge Planters ❑ Yes ❑ No `r �� °� �s 87 Stucco Brown -Finish 88 AC Unit Dscnnct, Elec-Pimb 89 Vnts abv Roof, Pimb-Appinc-Frplc-Cimc to Opngs 90 Wtr Well, Dscnnct, Elec, Pimb 91 Ext Elec Trim, GFl Rcptcl-Undrgmd DATE JELECTRICAL 40 Fxtr & Trnsfrmr Cirnc4ns Prtctn 41 Elec Rcptcls Spacing-Lts & Switches at Doors 92 Vntitn thru House 42 Sz Boxes & No Of Cndctrs Stapled 93 Glass Prtctn 43 Romex Installed Close to Edge of Studs & CJ 94 Corrections from previous Irispctns 44 Eqp Grnd made up w/Mech Fstnrs 95 Gas Test -Meters Tagged, Gas-Elec 45 Grndng Electrode Bond Gas & Wtr 96 Wtr & Sewer Cnnctd-C/O to grade -HD Apprvl 46 2 Appinc Cires in Ktchn & Cndctr Sz GFl 97 Energy Cmpinc Cert -Other Certs 47 Subfeed Wire Sz El cu or DAL 98 Address Posted AC Wire Sz ya ❑ CU or ❑AL 99 Fire Sprinkler 48 Range Circ w ❑ CU or ❑ AL Oven Circ ya ❑ CU or ❑ AL Insulated Neutral ❑Yes ❑No 49 Service -Riser Cndctrs & Grnd Main Dscnnct 50 Eqp Clrncs pnis-Motors-Mech Eqp 51 Clothes Closet Lt-Shwr Lt -Spa Lt 52 Smoke Detector BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7696 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAM (530)538-2140 -WEBSITE: www.buttecounty.net\dds LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. License Class: License Number: Date: Contractor. OWNER -BUILDER DECLARATION I hereby affirm under penalty' of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its Issuance, also requires the applicant for such permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's Slate License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the apppplicant to a civil penalty of not more than five hundred dollars ($500).): fY! I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, provided that such improvements are not intended or offered for sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of proving that he or she did not build or improve for the purpose of sale.). ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). ❑ I }a�m Exempt �xeem— iptt�uunder Article 3 of the Business and Professions Code Dale: L Owner: WORKERS' COMPENSATION DECLARATION I hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ❑ I have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier: Policy #: m I certify that in the performance of the work for which this permit is issued. I shall not employ any person in any manner so as to become subject to the workers' compensation laws of California, and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Applicant: WARNING: Failure to secure wa ers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. PERMIT NO. BP061818 Issued Date: 08/15/2006 APN: 065-380-007-000 Site Address: 14713 DURAMEN CT MAG Map Index: Description: deck (360) Owner: KEMP LYNN B JR & MARY F P O BOX 753 MAGALIA, CA 95954-0753 Applicant: KEMP LYNN B JR & MARY F P O BOX 753 MAGALIA, CA 95954-0753 (530) 873-0914 Contractor: License #: Architect: Engineer: Total Square Ft: 360 S.F. Valuation: $3,600.00 Census Code: -s Wicp, 4qay"o ec4q 5 �� CONSTRUCTION LENDING AGENCY This permit is hereby issued under the applicable provisions or the 91 ine (:ounty'C:oan minor' I hereby affirm that there is a construction lending agency for the ResoI io s to do work indicaI d ab ve for which fees have been paid. l performance of the work for which this permit is issued (Sec 3097 Civ.) 5 Name: BY Date: PERMIT XPIRES ON: Address: . fOafal ❑ I hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte County to enter upon the above mentioned property for inspection puMA== Print Na. t/�►/ �� Signature: Date: — D 3 Owner 0 Contractor 0 Agent for Owner 0 Agent for Contractor 065-380-007 1.CEMP, LYNN C, NOTES 14713 DURAMEN CT, MAGALIA 3 Cont: RIDGE CONSTRUCTION i°oor� g �,�"�� c�C�'t�Z 1C1� i�CetiCl-F Cjfc dj GjUy� ! GARAGE(2 CAR) RES IDENTIAL APN: Permit No. Owner. Site Address: Contractor. Type of Permit: CHECKED BY FLOOD CERTIFICATE EQUIRED FIRE SPRINKLERS REQUIRED SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUBSTANDARD HOUSING LETTER ENCROACHMENT PERMIT REINSPECTION FEE PAID ENV HLTH CLEARANCE OFF r2as&-wcOz DATE JOB FINALED: A — /,— 1-0 SIGNATURE: �e j +=OK n = u•,t nu MANUFACTURED HOMES MISCELLANEOUS - DATE PERMANENT FOUNDATION SOFT -SET 1 Zoning -Setbacks -Easements 2 Solis; Special MH Support Sketch 3 Sewer; Loctn-Test; FaII/CIO-Concrete 4 Wtr; Loctn-Test-Easement Needed -Regulator 5 Elec Loctn-Clmcs-Grnd Am -Concrete 6 Yard Gas; Loctn-Test-Wrap ' Nat or LPQ Inch Sz Ft Lngth 7 Blckng; SzSpacing-Marriage Line 8 Gas; MH Test-Demand-Valve-Cnnctr 9 Elec MH Cntnty Test-Crossovers-Breakers-Clmcs 10 Drain; MH Test -Fall -Flex Cnnctr 11 Wtr & Sewer Connected -CIO to Grade 12 Gas and Electricity Tagged 13 Tie Downs Q Foundation ❑ 14 Exits 19 Cert of Occupancy IS 16 HUD Label/Insignia Numbers Serial Numbers -'--DATE DEC O V E R S'C A R P O R T •GARAGE S Co' onmSetbacks-Easements C09 4.Fr9s; SoilsSz DpthSpacing-CnnctrsSteel ,fnc--to XU, 3 Decks, Girders/Joists-0cking-Brcing Stairs-Guard/Handrails 4 Wood Awn; Posts-Beams4bas-CnnctrsShthg. Frmg-Brcng 5 Alum Awn; Columns-CnnctnsSpiice-Decal-Encisrs 6 orts; Wndws-Doors lel C .B-Fr�9; Sills-AnchrsStuds-Rftrs Trusses "iding; Nailing-VengerStucco-Lath 10 R f, Sh"-Roofing Weeps -Doors -Landings raced Wall pnls -- o' QV DATE IPOOLS 1 Setbacks -Easements 2 Soils; CompactionStructure.Stability 3 Pool Structure; Steel-Cnnctns-Thickness Dead Men4Jning 4 Elec Reptcls1l ting; Distance -GR 5 Elec Pool Lting; 15 volts-GFI 6 Elec.Encisrs; Conduit Entries Terminals -Listed . 7'Elec Bonding; Metal w/5'-DrcItng Egp-Htr 8 Elec Grndng; Eqp w/5' Crcltng Eqp-Pool Ightg Boxes-Enclsrs-polboeids4nsultn4o Main Conduit 9 Health Dept Apprvl 10 Plmb; Cir Test-Wtr Supply Test 11 Lt Niche , 12 Encisr. Fencing -Alarms 13 Bonding. Diving board or Slide 4P o's' °'A Pool Drawing I J t a = Noe RESIDENTIAL (Single & Duplex) DATE JUNDERFLOOR DATE IPLUMBING 1 ZoningSetbacks-Easements-FloodSlope 53 Wtr Htr; Vent-Acc-Cmbstn Air Ba e- ., 2 Ftg Main; Soils-Elec Gmd Ftg Dpth 54 Wtr Pipe; Test & Anchr-Nail Prtctn 3 Ftg Garage; Soils-Steel-Elec Grnd Ftg jppth 55 DWV; Test Fittings & Anchr Nail Prfctn 4 Ftg Porches/Decks; Soils -Steel Ftg Dpth 56 Shwr Pan; Test, First fir -Tub Ace 5 Stemwalls' Wain; Steel-Blockouts Wrapped 57 Test Tuti & Shwr, 2nd fir - Tub Acc 6 Stemwalls Garage; Steel-Blockouts-Wrapped 58 Gas Pipe; Sz & Anchrs 6a Hold Downs and Special Anchrs 59 Fire Sprinkler; Test 7 Slab, Steel Wrapped 60 Yard Gas.Piping 8 Piers-Frpic Ftg-Steel 9 DWV; Fail -Fitting -Test -2 -way CIO -Sewer Test Ole 41 �s 10 UF, Gas Pipe; Sz Anchrs-Sz Test ole d 11 Wtr Pipe; Test-Anchrs-RgltrService Test 12. Elec Undrgrnd DATE M E C H A N71 C A L 13 Plenums & Ducts; Clrnc-MaterialSupport4nsultn 61 AC Ducts Insulin & Support 14 GirdersSills-Anchr Bolts-Joists-Vnts-Cripples 62 Vent Fan, Exhaust abv Insulin 15 Acc & Vntitn 63 Condensate Drain & Ovrflw, Sz & Grade 16 Insulation 64 Furnace -Vent Acc-Comb Air Rtrn/Vent 115 Outlet 65 Attic Acc & Pltfrm if Furnace In attic DATE IrRAMING 17 Sills Proper Materials & Anchrs DATE F 1 N A L 18 Walls Studs -Nailing Spacing & Braces -Plates -Sound 66 Ext Steps -Door & SideLt Prtctn-Landings 19 Bearing Wails over Girders ,& fir Nailing 67 Smoke Detector 20 Draft Stop in Walls (rat proof) ' 68 Furnace Vnts-Cimc-Comb, Air-Cnnctr 21 Fire Stops,. Furred CeilingsStairs-Chasers-Tubs r.i In Garage; abv-flr-Ducts-Meth Prtctn 22 Headers & Beam4&Bearing 69 Bedroom Exiting 23 Hangers-Posf Caps-Anchrs-Cnnctns 70 GFI & Bath Fxtrs & Tub Acc-Spa 24 Ceiling Joist-Rftr Ties -Pur -Roof BracTmssShthg 71 GFI Arc Fault 25 Frpic Ties or Type A Flue-Frpic Throat Cimc 72 Elee Trim & Subpnl, Breaker Szs & Labels 26 Attic Acc; Sz & Rrnz Prtctn-Draft Stop -Ins Baffles 73 Stairs, Guard/Handrails 27 Bdrm Wndws or Exiting Doors -Sill Ht & Dimensions 74 Frpic or Stove, Cirnc-Hearth 28 Garage Fire Prtcth Framing -RC Channel 75 Elec Outlets at Wood Pnl, Int & Ext 29 Prprty Line Firewall & Opngs' 76 Ktchn, Fxtr & Appinc; Gmd Air -Gap -Cooking Cimc 30 Ext Doors -One 3' -Check Garage 3rd Story, 2 Exits 77 Elec Outlets & Rcptcls at Ktchn Counter 31 Stairs; Width-Hdrm-Rise-Run-Landing-Fire Prtctn 78 Garage Fire Door, Swing -Landing -Closure 32 Plywd on Roof Ovrhng-Attic Vnts-Rftr Ou rgrs 79 AC Duct in Garage -Damper. 33 Siding -Nailing Veneer 80 Wtr Htr; Vnts-Clmc-Com Air Cnnctr-PRV; abv fir 34 Stucco Lath -Weep Screed-Fndtn Vnts-Undrflr Acc Mech Prtctn; LPG Appince Undr House 3" drain 35 Glazing Area -Glass PrtctnSkyLts-Plastic . 81 Plmb; Elec & Mech Eqp Listed for Loctn 36 Shear Walls; Nailing -Bolts 82 Elec Rcptcls in Garage (GFI) Romex Prtctn 37 Brace Int/Ext Wall pnis 83 Insultn-Foam-Looked in Attic 38 insultn-Walls-Ceilings 84 Guard Rails & Deck Cnstrctn-Post Caps 39 Infiltration-Walls-Wndws 85 Fndn Vnts & Crawl Hole Door Dmge & Wood -Earth 86 Cirnc Drnge Planters Q Yes ❑ No #� o' °mss 87 Stucco Brown -Finish 88 AC Unit Dscnnct, Elec-Plmb 89 Vnts abv Roof, P1mb-App1nc-Frpic-Cimc to Opngs DATE JELECTRICAL 90 Wtr Well, Dscnnct, Elec, Plmb 40 Fxtr & Trnsfrmr Clrnc4ns Prtctn 91 Ext Elec Trim, GFI Rcptcl-Undrgrnd 41 Elec Rcptcls Spacing-Lts & Switches at Doors 92 Vntitn thru House 42 Sz Boxes & No Of Cndctrs Stapled 93 Glass Prtctn 43 Romex Installed Close to Edge of Studs & CJ 94 Corrections from previous Irispctns 44 Eqp Grnd made up w/Mech Fstnrs 95 Gas Test -Meters Tagged, Gas-Elec 45 Gmdng Electrode Bond Gas & Wtr 96 Wtr & Sewer Cnnctd-CIO to grade -HD Apprvl 46 2 Appinc Cires in Ktchn & Cndctr Sz GFI 97 Energy Cmpinc Cert -Other Certs 47 Subfeed Wire Sz W ❑ CU or QAL 98 Address Posted AC Wire Sz ya Q CU or Q AL 99 Fire Sprinkler 48 Range Circ ya Q CU or Q AL Oven Circ oa Q CU or QAL Insulated Neutral [::]Yes [:j No o+° 49 Service -Riser Cndctrs & Gmd Main Dscnnct 50 Eqp Clrncs pnis-Motors-Mech Eqp 51 Clothes Closet LtShwr LI -Spa Lt 52 Smoke Detector COUNTY OF BUTTE F BUILDING DIVISION r; 'DEPARTMENT OF DEVELOPMENT SERVICES 7 County Center Drive • Oroville, CA • (530) 538-7541 CORRECTION NOTICE r..w OWNEA PERMIT NO. 3w._, . A routine inspection indicates that the following violations of Butte County Ordinances exist at the above address and should be corrected. Please call for re -inspection when correction of } work is completed. If you have any questions pertaining to this matter, or need additional exDlanation. Dlease contact the Ruildinn Incnartnr ac indirntorl hnlnui r Date Inspector CO. k, C_— REV 4/05 Phone # FOR RE -INSPECTION CALL: 538-7636 OR 891-2834 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAM (530)538-2140 WEBSITE: www.buttecounty.netldds PERMIT NO. BP061817 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 08/15/2006 APN: 065-380-007-000 the Business and Professions Code, and my license is in full force and effect. License Class : License Number: Site Address: 14713 DURAMEN CT MAG Date: Contractor. Map Index: Description: det garage (672) OWNER43UILDER DECLARATION 1 hereby affirm under penalty' of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a Owner: KEMP LYNN B JR &MARY F permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a P O BOX 753 signed statement that he or she is licensed pursuant to the provisions of MAGALIA, CA the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or 95954-0753 she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is' not intended or offered for sale (Sec. 7044, Business and Professions Applicant: KEMP LYNN B JR & MARY F Code: The Contractors' State License Law does not apply to an P O BOX 753 owner of property who builds or improves thereon, and who does such work himself or herself or through his or her own employees, MAGALIA, CA provided that such improvements are not intended or offered for 95954-0753 sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of (530) 873-0914 proving that he or she did not build or improve for the purpose of sale.). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does Contractor: RIDGE CONSTRUCTION CO not apply to an owner of property who builds or improves thereon, • and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). PO BOX 2215 O I am Exempt under Article 3 of the Business and Professions Code 95967-2215 Date: 0 600wner: 530-872-4716 License #: 577135 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Architect: is issued. Engineer: ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Total Square Ft: 672 S.F. Policy #: Valuation: $16,128.00 Census Code: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to��'t become subject to the workers' compensation laws of California, ' and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions. Date: Lo Applicant: WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and one hundred thousand dollars ($100,000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY This permit Is hereby issued under the applicable provisions of the Butte County Coda ?ndlor I hereby affirm that there is a construction lending agency for the Resolutionp to do work indicat d abo a for which fees have been paid. performance of the work for which this permit is issued (Sec 3097 Civ.) . Name: Date: By:pr r E O PERMIT ES Address: PIR7- ON: c Date ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safety Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives of Butte Countyto enter upon the above mentioned property for inspection purp os. Print Name: l\pi off' Signature: /O -V/J� Date: >! `1 • : 0 Contractor ❑ Agent for Owner 0 P/Owner Agent for Contractor BUTTE COUNTY DEPARTMENT dF DEVELOPMENT SERVICES BUILDING PERMIT 24 HOUR INSPECTION #: (530) 538-7636 (OROVILLE) (530) 891-2834 (CHICO) OFFICE #: (530) 538-7541 FAM (530)538-2140 WEBSITE: www.buttecounty.netldds PERMIT NO. BP061817 LICENSED CONTRACTORS DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of Issued Date: 08/15/2006 APN: 065-380-007-000 the Business and Professions Code, and my license is in full force and effect. License Class : License Number: Site Address: 14713 DURAMEN CT MAG Date: Contractor. Map Index: Description: det garage (672) OWNER -BUILDER DECLARATION I hereby affirm under penalty' of perjury that I am exempt from the Contractors' State License Law for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county which requires a permit to construct, alter, improve, demolish, or repair any structure, prior Owner: KEMP LYNN B JR &MARY F to its issuance, also requires the applicant for such permit to file a P O BOX 753 signed statement that he or she is licensed pursuant to the provisions of MAGALIA, CA the Contractor's State License Law (Chapter 9 commencing with Section 7000) of Division 3 of the Business and Professions Code) or that he or 95954-0753 she is exempt therefrom and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500).): 0/1, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Applicant: KEMP LYNN B JR & MARY F Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who does P O BOX 753 such work himself or herself or through his or her own employees, MAGALIA, CA provided that such improvements are not intended or offered for 95954-0753 sale. If however, the building or improvements are sold within one year of completion, the owner -builder will have the burden of (530) 873-0914 proving that he or she did not build or improve for the purpose of sale.). ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code. The Contractors' State License Law does Contractor: RIDGE CONSTRUCTION CO not apply to an owner of property who builds or improves thereon, . and who contracts for such projects with a contractor(s) licensed pursuant to the Contractors' State License Law.). PO BOX 2215 D 1 am Exempt under Article 3 of the Business and Professions Code 95967-2215 01� 0 LO Date: Owner: 530-872-4716 License #: 577135 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: Cl I have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by Section 3700 of the Labor Code, for the performance of the work for which this permit Architect: is issued. Engineer: ❑ 1 have and will maintain workers' compensation insurance, as required by Section 3700 the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carder: Total Square Ft: 672 S.F. Policy u: Valuation: $16,128.00 that =his Census Code: rtify in the performance of the work for which is issued, I shall not employ any person in any manner so as to I become subject to the workers' compensation laws of California, y1 l and agree that if I should become subject to the workers' compensation provisions of Section 3700 of the Labor Code, I shallr forthwith comply with those provisions. 1 �`� U �D �0 Dale: I Applicant: WARNING: Failure to secure workers' compensation coverage is {,c unlawful, and shall subject an employer to criminal penalties and one - hundred thousand dollars ($100,000), in addition to the cost of -15M( 6- (` ] compensation, damages as provided for in Section 3706 of the Labor code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY This permit is hereby issued under the applicable provisions of the Birtte County Code antvor I hereby affirm that there is a construction lending agency for the Resolutio to do work indiaat d abo a for which fees have been paid. performance of the work for which this permit is issued (Sec 3097 Civ.) Ah ' Name: BY,--+ pr Date: - © ' PERMIT E PIRES ON: Address: Date ❑ 1 hereby certify that the use of this facility shall comply with Sections 25505, 25533, and 25534 of the California Health and Safely Code, which regulate the storage, handling and use of hazardous materials. ❑ Notification in accordance with Section 19827.5 of California Health & Safety Code is not applicable to the scheduled construction of this project. ❑ Attached are copies of the required E.P.A. notification forms. I hereby certify that I have read this application, that the above information is correct, and that I am the owner or the duly authorized agent of the owner. I agree to comply with all county and state laws relating to building construction. I acknowledge it is unlawful to alter the substance of any official form or document of Butte County. I hereby authorize representatives Butte County to enter upon the above mentioned property for inspection purp os. fof Print Name: I�n%/V &,W-NOSignature: Date: _�' O Owner ❑ Contractor ❑ Agent for Owner 0 Agent for Contractor BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS OFFICE #: (530) 538-7541 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" OWNER INFORMATION Last Name Q. m irst NameEq n Address ( 90 ro— m e_n City irv� �f ; '(,1� State c, am_ Zip Phone 3 9 A4 Fax E-mail M CJ\� GO 0 S J. C) r APPLICANT INFORMATION CONTRACTOR Name Name Ton r n 6_ , t°' Address State U* State City Phone State Fax Zip Phone State License Number Fax E-mail Lic. # 61Y 7 q I Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name Address 1`C / f 13 Address City C`na o�_t 1 City State U* State Zip Phone E-mail 1_ _ Fax E-mail Date Approved: State License Number APPLICANT INFORMATION Name 0 r) Address 1`C / f 13 (D car --o m0- o City C`na o�_t 1 Type Const. State U* Zip p� I f Phone 3 __0 / /L( Fax E-mail 1_ _ APPLICANT SIGNATURE m X For office use only. AP# v -3g)- 00 2_0 00 Zoning I Flood Zone JSRA Yes' No Occ. WORKER'S COMPENSATION Type Const. Subdivision Name If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. Map Book Page Lot # Planner Date Approved: OVER FOR SUBMITTAL REQUIREMENTS PERMIT NO. BPp6l S BIN # PROJECT LOCATION AP# v -3g)- 00 2_0 00 Property Address Ll 7 13 PurcL rn en NO, 4f City Imixiql-aAe, Cross Street , n S a c Y�Q e�0o J W�- WORKER'S COMPENSATION Policy Number Carrier If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name W Address F0 8oX j -9o8' 0L� ,1_n 'e -rd OP T•S�G -$ Q escription or Scope of Work: Sq FT- Living Garage & 7a Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Received by: Amount: 21 96 Bldg zo SRA Receipt #: 00 Sheriff SMIP �7 Other Date: u Total K:\FORMS\BUILDING FORMS\BldgApplSubRgmts.doc Page 1 of 2 REV 4-10-06 COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION 7 County Center Drive, Oroville, CA .95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATION DATA SHEET OWNER: ��y 'ASSESSOR PARCEL NUMBER Proposed Building Use: % ��T - 6 '7` 6 L C% / (. Permit Technician: (iC-`�� Date: Items required in order to apply for a permit. All boxes MUST be checked OR marked NA in order to apply. \ /ti . 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. �7/ Ai 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. O 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. / N 4. Engineered truss details and layouts in duplicate. No faxesl ❑ 5. Letter from Engineer or Architect for truss design review. ❑ 6. Energy compliance design and supporting documentation in duplicate. ❑ 7. Statement of Intent for Non -heated and A/C for Non -Residential Buildings. ❑ 8. Manufactured homes: (A) Installation manual, including marriage line info, (C) Floor Plan, (D) Tie down or fnd plans, all in duplicate. ❑ 9. Metal bldgs: (A) Metal Bldg Plans, (B) Fnd plans and calcs in triplicate, (C) Elevations in triplicate. (D) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. ❑ 10. Flood Elevation Certificate, wet -stamped and signed, in duplicate. ❑ 11. Hazardous Material Form N 12. Acknowledgement of building permit application without required clearances. ❑ 13. Other ainingliftems needed to issue the permit. (May require additional plan review upon receipt of the ollowing items. Sanitation and site plan approval from the Environmental Health Department in hico vill , able ( 5. ire Sprinklers................................................................................... ❑ 16. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by ❑ 17. Soils Report and/or Engineered Foundation required ........................................... 18. Erosion Control Plan Required .......................................... i 19. Fees as shown on the attached Schedule of Fees Due Sheet, ....1 ............... 0. City of Chico Plumbing permit....................................................................... - ❑_ 21. Site plan and business license approval from the City of Biggs ............................. 22. California Department of Forestry plan approval-EpaW-96nt by: 'El 23. Planning approval for (A) Use: 6 L (B) Parking: (C) Parcel Check:....... Z ❑ 24. Contact Land Development about _ Improvements, _ Drainage ........................ ❑ 25. Fire Marshall Review (commercial projects only). Sent by: ...................... IN 26. NPDES Form............................................................................................. ❑ 27. Encroachment Permit for driveway from the Public Works Dept ........................... O 28. Contractor's license information. (Number, Name Style, Classification) ................... \ ❑ \ .29. Worker's Compensation Carrier and Policy Number .......................................... 1 30. Owner -Builder Verification ( _ Given to owner, _Mailed to owner) ..................... ❑ 31. Letter of Signature authorization.................................................................... ❑ 32. Recorded copy of Agricultural Acknowledgment Statement ................................. ❑ 33. Existing violations and/or expired permits......................................................... ❑ 34. Deed Restriction.......................................................................................... ❑ 35. ❑ Legal description, ❑ M.H. Title, title search, registration or MCO ......................... ❑ 36. Other: ❑ 37. Other: When issued Telephone v /NN .5 7 '5_0 I_4 L and hold for pickup. I have been informed of the above items and requirements for obtaining a building permit. Applicant: ,c/_ ti-. _� A Date: 1. Index permit application ifVve' umb�eree di r �i Plan Check Letter 2. Additional items required (tet 1 r Contractor, design wne as vise he above data by phone, ❑ mail, ❑'coun'ter, by Date:_ (Q Contractor, designe , er, was advised of the above data by ❑ phone, ❑ mail, ❑ counter, by Date: Contractor, designer, owner, was advised of the above data by ❑ phone, ❑ mail, ❑ cou ter, b Date: Plans reviewed by: Date: 8 • /V• o9Z Plans approved by: Date: �3 . /�^ • Dl Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Date: Yellow: Building Division K/Building/Plan Check/Data Sheets/data sheet page 2 9.27.05 BUT'T'E COUNTY E.H. N Plot Plan Adadred r Flow Plan Attadwd AUGVV 2 0n 96 Sent to 8D/DS TO: Building Division — Development Servie%',,5'ELOPIE��W,'NTQ1,o FROM: Environmental Health SUBJECT: Sanitation Clearance /� r\ /y.tJN /t/=/rd�. /`�`%-s �JU2�i'►'I,�I� �. ®&S -SPO -007 Owner Location AP# Plan Approved for: Sewage Disposal: ✓ Water Supply: Public ✓ Private Well Clearance for dwelling. Other 2 O4 -f"0200 -f—.O . �°G.4.v s . Hold final for: Final cleara a O.K. for: NOTE: ot Environmental Health Sp c list to Building Clearance 9/2005 r BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 www.buttecounty.net/dds PHONE (530) 538-7541 FAX 538-2140 RECEIPT OF FEES SCHEDULE - RESIDENTIAL Owner kemp APN No: 65-380-007 Permit Type: 'v Subtype: App Date: 7/28/2006 Permit No: BP 06 1817 Permit Desc: 1 BUILDING PERMIT FEES ESTIMATED AT APPLICATION Plan Check portion of Permit Fee 2 FEMA BYes Flood Elevation Review $109.98 3 'SRA* x Yes Fire Plan Check - Non -Refundable $95.00 (State Responsibility Area) Building Inspection $109.98 NON-REFUNDABLE portion of fees due at application $549.90 $219.96 $329.94 Balance of Building Permit Fee 0 $95.00 $204.98 $109.98 $314.96 FEES DUE AND PAYABLE AT TIME OF PERMIT APPLICATION ��$44�24194FEES (BELOW) DUE PRIOR TO ISSUANCE OF PERMIT RECEIPT DATE Tech/Asst '7-2,6 1 4 Balance of Building Permit Fees (from No. 1 above) .94 _ 5 SMTP* - Strong Motion Instrumentation Program (Enter amount from permit system) 6 Additional Plan Check Fees (NON-REFUNDABLE) 7 Other*: 7a Other*: 8 IMPACT FEES - RESIDENTIAL* Per A I' tAft 04/15/06 MH 3238.72 5648.44 2422.68 8075.40 /ca /ons eI QVL MFD $200.00 County 4249.111 3183.54 Chico Urban Area 6146.231 4538.82 EI Medio Fire District 3249.971 2385.76 North Chico Specific Plan SR -1, SR -3, SR-1/PD 8801.09 7395.04 R-1 8897.09 7491.04 do R-2 8390.09 6984.04 R-3 7604.09 6198.04 Processing Fee is automatically added to impact fee total 0 9 WATER TENDER FEE (Not collected when Imp actFees Applicable) Enter Bat.# DRAINAGE FEES* MH 3238.72 5648.44 2422.68 8075.40 RECEIPT DATE Tech/Asst � 7289.40 $100.00 $200.00 10 CHICO STORM DRAINAGE 770 Butte Creek MASTER PLAN 771 Comanche Creek 772 Little Chico Creek 773 Big Chico Creek New construction, vacant 774 Lindo Channel land, on 1 acre or less - 775 SUDAD Ditch Enter 1 or less acre value 776 Mud -Sycamore Creek 777 PV Ditch 10a More than 1 acre, existing buildings - fees to be assessed by Public Works Fee Determination Sheet Needed - Enter amount determined by PW 11 THERMALITO DRAINAGE AREA 1 $684 Maximum Per each new living unit on existing lots where full drainage fees have not been paid 11a Temporary Dwelling 1 $136 At time of building permit $136 annual renewal fee for first 4 renewals. Not to exceed $684. PROOF OF PAYMENT OF FEES (BELOW) MUST BE RECEIVED PRIOR TO I is completed for applicant to take to respective district office. 12 SCHOOL DISTRICT FEES* � 12a RECREATION DISTRICT FEES` 341 688 776 267 $6,275 RECEIPT DATE Tech/Asst $8,893 10 D CE OF PERMIT. Forms will be prepared after plan check At the time of permit application, I was advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the plan checking process. O Applicant: Date: - (- U Pursuant to Government codg Section 66020, you are h reby nbtified those Items followed by an "" may have been imposed on your project. You have 90 days from the date of approval of the porject or from the impostion of the above referenced items during which you may protest. The requirements for a protest are specified in Goverment Code Section 66020(x). K:/Building/Forms/Schedule of Receipt Fees Residential 041506 P pRTM�NT O� 6VTr� r o� I ` ° 11 0 \\Acout4- ' S �Qtic WOP� Department of Public Works J. Michael Crump, Director LAND DEVELOPMENT DIVISION Storm Water Management Program 7 County Center Drive Oroville, CA 95965 (530) 538-7266 (FAX) 538-7171 National Pollutant Discharge Elimination System (NPDES) Phase II Construction Storm Water Permit and Storm Water Pollution Prevention Plan (SWPPP) Acknowledgement [LESS THAN 1 ACRE1 . Project Description: Project Location and/or Parcel Number: V 3 0 — By signing below, I, the project owner/owner's agent, certify that this project WILL NOT DISTURB 1 acre or more of land and that I, therefore, do not need to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. Phased projects that contain multiple site build -outs of less than one acre but when combined with subsequent phases total more than one acre of disturbed soil will require a Construction Storm Water Permit from the State of California Regional Water Quality Control Board. I am aware that submitting false and/or inaccurate information or failure to apply for a Construction Storm Water Permit from the State of California Regional Water Quality Control Board for a project that disturbs one acre or more of land may result in revocation of grading and/or other permits or other sanctions provided by law. Signed: Title: Date: T') — �?,Ff U Less than 1 Acre NPDES & SWPPP Compliance Certification Butte County Storm Water Management Program . Revised 5/24/04 OWNER -BUILDER VERIFICATION Attention Property Owner: An "owner -builder" building permit has been applied for in your name and bearing your signature. Please complete and return this information at your earliest opportunity to avoid unnecessary delay in processing and issuing your building permit. No building permit will be issued until this verification is received. \l. I personallyPlan to provide themaarbor and material for construction of this proposed property impr(ement: YES .[ NO [ ]. 2. I HAVE [ HAVE NOT [ ] signed an application for a building permit for the proposed work. 3. I have -contracted with the following person (firm) to provide the proposed construction: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: ' 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise, and -provide the major work: NAME: _ ADDRESS: PHONE: CONTRACTOR'S LICENSE NO: 5. I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated: NAME ADDRESS PHONE TYPE OF WORK SIGNED: PROPERTY OWNER - 0 � u . DATE: �9 NOTE: This Owner -Builder verification is required by Section 19831 and 19832 of the California Health and Safety Code. This verification must be completed and returned to our office before we are permitted to issue the Butte County Department of Development Services ADMINISTRATION t BUILDING. GIS: PLANNING 7 County Center Drive Oroville, CA 95965 (530) 538-7541 Telephone (530) 538-2140 Facsimile OWNER -BUILDER INFORMATION Dear Property Owner: An application for a building permit has been submitted in your name listing yourself as the builder of the property improvements specified. For your protection you should be aware that as "owner -builder" you are the responsible party of record on such a permit Building permits are not required to be signed by property owners unless they are personally performing their own work. If your work is being performed by someone other than yourself, you may protect yourself from possible liability if that person applies for the proper permit in his or her name. Contractors are required by law to be licensed and bonded by the State of California and to have a business license from the city or county. They are also required by law to put their license number on all permits for which they apply. If you plan to do your own work, with the exception of various trades that your plan to subcontract; you should be aware of the following information for your benefit and protection: o If you employ or otherwise engage any persons other than your immediate family, and the work ('including materials and other costs) is $200 or more for the entire project and such persons are not licensed as contractors or subcontractors, then you may be an employer. o If you are an employer, you must register with the state and federal government as an employer and you are subject to several obligations including state and federal income tax withholding, federal social security taxes, workers' compensation insurance, disability insurance costs, and unemployment compensation contributions. o There may be financial risks for you if you do not carry out these obligations, and these risks are especially serious with respect to workers' compensation insurance. o For more specific information about your obligations under federal law, contact the Internal Revenue Service (and, if you wish, the U.S. Small Business Administration). For more specific information about your obligations under state law, contact the Department of Benefit Payments and the Division of Industrial Accidents. If the structure is intended for sale, property owners who are not licensed contractors are allowed to perform their work personally or. through their own employees, without a licensed contractor or subcontractor, only under limited conditions. A frequent practice of unlicensed persons professing to be contractor is to secure an "owner -builder" building permit, erroneously implying that the property owner is providing his or her own labor and material personally. Building permits are not required to be signed by property owners unless they are performing their own work personally. Information about licensed contractors may be obtained by contacting the Contractors' State License Board in your community or at 1020 N Street, Sacramento, California 95814. Please complete and return the enclosed owner -builder verification from so that we can confirm that you are aware of these matters. The building permit will not be issued until the verification is returned_ Sincerely, A AYe�� Scott Rutherford Chief Building Inspector NOTE: This Owner -Builder Information is required by Section 19830 of the California Health and Safety Code. Butte COLUItyDepartmentofDeveloprr2entS'e -Wces o$UzrFo 7 County Center Drive t. a Oroville, CA 95965 _•:Y;. , a (530) 538-7601 Telephone .. , • :.:. o a (530) 538-7785 Facsimile c0UN�-1 BUILDING PERM APPLICATION WITHOUT REQUIRED CLEARANCES I request and authorize the Building Division to process this building permit application through the plans examination process WITHOUT first obtaining all necessary, related permits and clearances from other regulatory entities, including but not limited to, Planning, Environmental Health, Land Development, County Fire, and Agriculture. I hereby acknowledge: I need to submit applications for septic and/or well to Butte County Environmental Health immediately. I am required to bring the approved Environmental Health site plan and approved sanitation clearance to the Building Division as soon as clearance is obtained I am responsible for notifying Development Services, in writing, to stop processing of the application and to arrange for disposition of plans. The -Building Division will process the application through the plans examination process, as submitted, without input from other regulatory entities that could prohibit issuance of the building permit or require submission of amended building plans to the Building Division. Once the plans examination process begins, there will be no refund of plans examination fees. Any changes requiring submission of amended plans to the Building Division will incur additional fees. Within one year from the date of application for a building permit, all other required permits and clearances from other entities must be obtained for the permit to be issued. Failure to obtain these permits/clearances will void the application. Typically other required permits/clearances include; but are not .limited to, verification the parcel was legally created, adherence.to all mitigations and conditions imposed on the parcel at time of creation, as well as zoning requirements, legal access, and applicable set -backs and environmental issues (fire, agriculture buffer zones, and habitat/species). , Please print: Applicant Name: /1/ APN: G 6-6--3 Building site address: /; )43 0 Permit No.: I have read, understood and accept the terms and conditions as expressed herein as indicated by my submission of the above -referenced building permit application and my signature below: SIGNATU F OF APPLICANT U U DATE 0 Copy to ApplicanJEH/File Y`Forms/BldgPermitwithoutClearances 020705 AUG 0 2 2006 BUTTE COUNTY DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION AND SUBMITTAL REQUIREMENTS OFFICE #: (530) 538-7541 A FEE WILL BE REQUIRED AT TIME OFAPPLICA TION Website: www.buttecounty.net/dds "PLEASE PRINT CLEARLY" OWNER INFORMATION CONTRACTOR Last Name Q Nle irst Name r n AddressL -7 1 V 9v rQ rn e—'l 4-� City `�r1��L.A-� i U` -State I' n Zip Phone M 3 .-,Q 9 1 � 3 / Fax State E-mail }'n 0,),-\1C.0:J S 9D� 11 APPLICANT INFORMATION CONTRACTOR Name Name Ton H-orn6�,c_% r Address Fax State City Phone State Fax Zip Phone 5 �_ �� Fax �_ a E-mail Lic. # t j l Class APPLICANT INFORMATION ARCHITECT/ENGINEER Name `; 0�_ City nA Address Zip ps q j—� l City Fax State Zip Phone Lot # Fax E-mail Date Approved: State License Number APPLICANT INFORMATION Name [—( n 11 Address 1/ I 1 3 (%o� -O m a o 0__* t `O' `; 0�_ City nA State Zip ps q j—� l Phone � ?1. ,_L q fq Q Fax E-mail ri--\ Lc n i C_o v S 1 9 - APPLICANT SIGNATURE 0 X A4 � U 'e-1— For office use only: /' AP# V t,p J `3D o— 009-6 00 Zoning 'F j I Flood Zone SRA L Yes) No Occ. WORKER'S COMPENSATION Type Const. Subdivision Name If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. Map Book Page Lot # Planner Date Approved: OVER FOR SUBMITTAL REQUIREMENTS PERMIT NO. BPob/S/ BIN # ,���� PROJECTLOCATION /' AP# V t,p J `3D o— 009-6 00 Property Address, n 4 `-1 71--5 Pura rn e4,) lit • City • o c—t i o— Cross Street . k0Se,,__)ood. c%- _S WcL WORKER'S COMPENSATION Policy Number Carrier. If hiring anyone other than license contractors, a certificate of worker's compensation must be shown at the time of permit issuance. LENDING AGENCY Name Oe-il s F6Lta . o Address P06OX j �C),r _ escription or Scope of Work: Sq FT- Living =Garage 7a Open Cov ❑ Structure Built without Permits ❑ Proposed Change of Occupancy (Note previous use): EXPIRATION OF APPLICATION Applications for which a permit has not been issued will expire one year after the date of application. In order to renew action on an application after expiration, a new application, plans and fee will be REQUEST FOR REFUNDS Refunds can only be made upon written request by the person who paid the fee. The request must be made prior to the expiration of the permit and no construction work has been done. Filing fees, plan check fees for work plan checked and other department costs are not refundable. Received by: Receipt#: A\1 Dater 7' "9� Amount: Bldg SRA Sheriff SMIP Other ?61C i Total K:\FORMS\BUILDING FORMS\BldgApplSubRgmts.doc Page 1 of 2 REV 4-10-06 NOTES RESIDENTIAL T i PERMIT NO. r 065-330-007 03-2834 ? I KEMP" LYNN t 14713 DURAMER CT, MAGALIA j Cont: EXECUTIVE HOMES NEW MH PERM FND EX SITE t t n SPECIAL CONDITIONS SRA FLOOD CERTIFICATE REQ. FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER RFs �3� I -A 7 t_ 627®'7,� SCI JOB FINALED (D ) d— Signatur CHECKED BY J=OK 0 = NotOK . = NotReadyable 8. ' MOBILE HOMES Date MOBILE HOME UTILITIES (Plans) OK except #'s Siding; Nailing -Veneer -Stucco -Mesh 1. Zoning Requirements -Setbacks -Easements Roof; Shthg-Roofing 2. Soils; Special MH Support Sketch Ext.; Steps -Doors -Landings 3. Sewer; Location -Test -Fall -C/O -Concrete Braced Wall Panels 4. Water; Location -Test -Easement Needed (Sketch) 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Card B-1 Date Card B-1 6. Gas; Location -Test -Wrap;-/ P' L'ft. / P Nat. or/ P' L "ft./ P LPG Card B-1 Date Card B-1 7. Well Clearance & Disconnect 8. Utility Clearance 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining Date 4. Card B-1 Date Card B-1 Date 5. Car -1 Date Card B-1 Date W.ILLV21ME INSTALLATION (Plans) OK except #'s King Requiremen etbacks- Easements 1.40 7. F tincis; Size cino-Marriaoe Line 5. 'Vain; MH Teat--Fall-Flex Cgnnector ter; MH Test- ula r -Connector 7 ater and Sewer Connected -C/O to Grade -HD Approval Ilia& and .Electricity Tagged �. Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy Date Card B-1 Date Card B-1 Date %" Card B-1 Date Card B-1 Date PERMANENT SYSTEM (ONLY) i. Zoning Requirements -Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 3. Blocking 4. Gas; MH Test -Demand -Valve 5. Electricity; MH Test 6. Water; MH Test 7. Water and Sewer Connected 8. Gas and Electricity Tagged 9. Exits 10. License Decals . 11. Verify #'s with Office Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 F, MISCELLANEOUS Date DECKS, COVERS, CARPORTS, GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks, Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts-Beams-Rftrs-Connectors Shthg-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date POOLS (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining F 4. Elec.; Receptacles and Lighting, Distance -GH 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lght% Boxes-Enclosures-Panelboards-Ins. to Main Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche 12. Enclosure; Fencing -Alarms Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 J=OK 0 = Not OK - = Not Applicable . = Not Ready RESIDENTIAL (Single & Duplex) Date UNDERFLOOR (Plans) OK except #'s 1. Zoning -Setbacks -Easements -Flood -Slope 2. Ftg., Main; Soils-Elec. Grnd.-/ P' Ftg. Depth 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ /" Ftg. Depth 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 6a. Hold Downs and Special Anchors 7. Slab, Steel -Wrapped 8. Piers -Fireplace Ftg.-Steel 9. D.W.V.; Fall -Fitting -Test -2 Way C/O -Sewer Test 10. UF, Gas Pipe; Size Anchors -Yard Gas Piping; Size Test 11. Water Pipe; Test -Anchors -Regulator -Service Test 12. Electric Underground 13. Plenums & Ducts; Clearance -Material -Support -Ins. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 15. Access & Ventilation 16. Insulation Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date PLUMBING (Permit) OK except #'s 17. Water Htr.; Vent -Access -Combustion Air Baffle 18. Water Pipe; Test & Anchor -Nail Protection 19. D.W.V.; Test Fittings & Anchor -Nail Protection 20. Shower Pan; Test, First Floor -Tub Access 21. Test Tub & Shower, Second Floor -Tub Access 22. Gas Pipe; Sixe & Anchors 23. Fire Sprinkler; Test 72. Elec. Outlets at Wood Panel, Int. & Ext. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date ELECTRICAL (Permit) OK except #'s 24. Fixture & Transformer Clearance -Ins. Protection 25. Elec. Receptacles Spacing -Lights & Switches at Doors 26. Size Boxes & No. of Conductors Stapled 27. Romex Installed Close to Edge of Studs & C.J. 28. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 29. 2 Appliance Circuits in Kitchen & Conductor Size GF] 30. Subfeed Wire Size/ /ga. Cu or AI-A.C. Wire Size/ /ga Cu or Al 31. Range Circle/ /ga Cu or AI -Oven Circ. / /ga Cu or All Insulated Neutral ❑ Yes ❑ No _ 32. Service -Riser Conductors & Ground Main Disconnect 33. Equip. Clearances Panels-Motors-Mech. Equip. 34. Clothes Closet Light -Shower Light -Spa Light 35. Smoke Detector 87. Water Well, Disconnect, Electrical, Plumbing Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MECHANICAL (Permit) OK except #'s 36. A.C. Ducts Insulation & Support 37. Vent Fan, Exhaust above insulation 38. Condensate Drain & Overflow, Size & Grade 39. Furnace -Vent Access -Comb. Ait-Return Air Vent 115 Outlet 40. Attic Access & Platform if Furnace in Attic Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FRAMING (Permit) OK except #'s Date 41. Sills Proper Materials & Anchors Comments at Final: 42. Walls Studs -Nailing Spacing & Braces -Plates -Sound 43. Bearing Walls over Girders & Floor Nailing 44. Draft Stop in Walls (rat proof) 45. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 46. Headers & Beams -Size & Bearing t Date FRAMING (Continued) 47. Hangers -Post Caps -Anchors -Connectors 48. Cling. Joist-Rftr. Ties- Purl in -Roll Brac.-Truss-Shting.-Rtng. 49. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 50. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 51. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 52. Garage Fire Protection Framing -RC Channel 53. Property Line Firewall & Openings 54. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 55. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 56. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 57. Siding -Nailing Veneer 58. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 59. Glazing Area -Glass Protection -Skylights -Plastic 60. Shear Walls; Nailing -Bolts 61. Brace Interior/Exterior Wall Panels 62. Insulation -Walls -Ceilings 63. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 64. Ext. Steps -Door & Sidelight Protection -Landings 65. Smoke Detector 66. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 67. Bedroom Exiting 68. G.F.I. & Bath Fixtures & Tub Access -Spa 69. Elec. Trim & Subpanel, Breaker Sizes & Labels 70. Stairs & Rails 71. Fireplace or Stove, Clearance -Hearth 72. Elec. Outlets at Wood Panel, Int. & Ext. 73. Kit. Fixt. & Appliance; Ground -Air -Gap -Cooking Clearance 74. Elec. Outlets & Receptacles at Kit. Counter 75. Garage Fire Door; Swing -Landing -Closure 76. A.C. Duct in Garage -Damper 77. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 78. Plb.; Elec. & Mech. Equip. Listed for Location 79. Elec. Receptacles in Garage (F.F.I.)-Romex Protection 80. Insulation -Foam -Looked in Attic 81. Guard Rails & Deck Construction -Post Caps 82. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes _ 83. Following Instld./Drive ❑ Yes ❑ No/Walks O Yes ❑ No/Planters O Yes O No 84. Stucco Brown -Finish 85. A.C. Unit Disconnect, Electrical -Plumbing 86. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 87. Water Well, Disconnect, Electrical, Plumbing 88. Exterior Elec. Trim, G.F.I. Receptacle -Underground 89. Ventilation Throughout House 90. Glass Protection 91. Corrections from Previous Inspections 92. Gas Test -Meters Tagged, Gas -Electric 93. Water & Sewer Connected -C/O to Grade -HD Approval 94. Energy Compliance Certificate -Other Certificates 95. Address Posted 96. Fire Sprinkler Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, California 95965 • Telephone (530) 538-7541 6� (Rev. 12/96) ' APPLICATION AND PERMIT Aff+ ASSESSORPARCELNUMBER 065-380-007 ZDNING RT -1 BUILDING PERMIT OWNER LYNN & MARY KEMPTELEPr,0NE SgA' AVE� RIVERSIDE, GA 925C-3 .OWNER'S MAILING S EXECUTIVE HOBS 891-6992 SO. FT. OCC. BUILDING VALUATION 1�90 79,900-00 CONTRACTOR'S NA@042 ESPLANADE, CHICO TELEPHONE CONTRACTORS MAILING ADDRESS CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ ARCHRECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee $ 999-00 ARCHITECT OR ENGINEERS MAIUNG ADDRESS Plan Checking Fee $ 168135 BUILDING ADDRESS Energy Plan Checking Fee $ $ PERMIT FEE $ LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome% Other SPECIFY Each Trap 7.00 - Solar or heat um water heater 23.00 Water piping 15.00 15.O'D Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Installation ❑ Other{ Describe Work: INSTALL NEW 26'8" X 51' , \ t1AlWFACTURED HOME, ON FOUNDATION. EXISTING SITE Gas piping system 1 - 5 outlets 15.00 15,00 Building sewer 15.00 Mobile Home I S I G I W @20.00 PERMIT FEE S ELECTRICAL PERMIT Fling Fee 20.010 Main Service . OR LESS 23.00 I LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Bu iness a Pro essions Code, and my license is ' full fo ge-�nd effect. License Class / Lic. No. (C, L/ OWNER-BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service aooA To +000A 46.00 NEW CONST. OWELUNG OCCUP. SO OR ADONS. ( a ACc. sin S. 3.5¢FT: I,oµICONST. MULTI.O Rcr, @G 7,50 POWER APPARATUS s 151N. OUTLET CIR. 20 @ 1.00 EX. Occup. OUTLET OR FIXTURES SAL @ .SO Ex. Occup. oFIx�LEED�A Aa OR 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ 43.00 WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the Xperformance of the work for which this permit is issued. 1 have and will maintain workers' compensation insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My work com sa 'o n e carri r end polic numb (� Carrier Policy Number Z4 G (The above sections need 6otWe o6rriprreteffrf ermi f r work of a valuation of one hundred dollars ($100) or less.) [31 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if I should become subject to the workers' c ensation provisions of section 3700 of the Labor Code, I shall forthwit co ply with th rovisions. % X Date �/ •��� nature of Applicant - Owner ❑ Contractor L�Agent An OSHA permit is required for excavations over 5'0" deep and demolition or c struction of structures over 3 stories in height. Receipt No. oZa • MECHANICAL PERMIT Filing Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEE $ Mobile Home Installation Fee Is Energy Inspection Fee Is occ CONST. TYPE OTAL FEE $ 555.35 HA2. D. F IMP FLOOD CDF PARC PO D - This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. B ¢D to O O P MIT EXPIRES O O 0 Date WHITE-D.D.S.-B.D. CANARY -ASSESSOR PINK -INS TOR GOLDENROD-APIRUC NT �t"'s.• .� � ttie _ �'•t - °l ...,ti.�.:a-.,.-+.: r�-�.�r.-.r �...r � ;�. . . Y t � :�+, _ .. COUNTY OF BUTTE -DEPARTMENT OF DEVELOPMENT SERVICES -BUILDING DIVISION ' 7 County Center Drive, Orovilie, CA 95965 Phone (530)538-7541 Fax (530)538-2140 PERMIT APPLICATIO;NLfl ATA SHEET OWNER: ASSESSOR PARCEL NUMBER G Proposed Building Use:A�4 6—'ngnter Technician: Date: I ems required in order to apply for a permit. II boxes MUST be checked Olt marked NA in order to yj$y. 1. Site plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 2. Complete plans, 3 or 4 sets, signed by the preparer of the plans. ❑ 3. Engineered plans, 3 or 4 sets, with wet signature on plans AND 2 sets of stamped and signed calculations. ❑ 4. En0ine4ed_6,6ss details and layouts in duplicate. No faxes! ❑ 5. Energy compliance design and supporting documentation in duplicate. , 6. Manufactured homes Data sheets and installation ins )) Marriage line in, ZFloor Pla ) Tie down or fnd plans, all in duplicate. ❑ 7. Metal bldgs: (A) Meta dg Plans, (B) Fnd plans and calcs in triplicate, (C) Eleva Ions in triplicate�_6) Floor plans in triplicate. All of these must be stamped and wet -signed by the engineer. Items required for initial plan review. If checked items have not been received, plan review cannot proceed. The permit will be indexed and returned to the plan review line-up when required items are received. Date Received By ❑ 8. Flood Elevation Certificate, wet -stamped and signed, in duplicate ................................ ❑ 9. Site plan and business license approval from the City of Biggs .................................... ❑ 10. Letter of intent for non-residential buildings................................................'......... ❑ 11. Detached Accessory Building Form filled out by the owner ..................................... J;O 12. Hazardous Material Form............................................................................... ❑ 13. Fire Sprinklers........................................................................................... . 14. Agricultural Buffer clr and site plan apr from the Ag Commissioner Sent by 'jz G rY ❑ 15. Other aining items needed to issue the permit. (May require additional plan review upon receipt of the f in s.) Fees as shown on the attached Schedule of Fees Due Sheet.....: .................................. Statement of Intent for Non -heated and A/C Buildings................................. r ' Sanitation and site plan approval from the Environmental Health Department i� 1 ity of Chico Plumbing permit ..................... .................. :.............Ce ............ California Department�of Forestry plan approval ❑paid. Sent by:4- �..f • e� 'I , Z 3 ' �3 21. Planning approval for (A) Use: �}` (B)Parking: (C) Parcel ck: ❑ 22. Contact Land Development about ❑ Improvements, ❑ Drainage ............................... . NPDES Form............................................................................................. W2524 . Encroachment Permit for driveway from the Public Works Dept ................................. . Pre -Inspection for r required ................ ❑ 26. Contractor's license information. (Number, Name Style, Classification) ...................... ❑ 27. Worker's Compensation Carrier and Policy Number ............................................. e28 Owner -Builder Verification (❑ Given to owner, ❑ Mailed toowner)..................... Letter of Signature authorization.................................................................... Recorded copy of Agricultural Acknowledgment Statement .................................... a, ❑ 31. Manufactured h me utility clearance............................................................... ❑ 32. Existing violatio nd/or expired permits............................................r,, ...... ❑ 33.� Grant Dee_ - Title/Statement of Facts ❑ Letter from Legal Owner ( Check to H.C.D. $ ❑ 34. Other: When issued Telephone and hold for pickup. I have been informed 5ple)llove items arld,requirements for obtaining a building permit. Applicant: / 1. Index per app ication for the above i ems numbered: Pan Check Letter 2. Additional items required rcppt[actg , esigner, owner, was advised of the above data by ail, ❑ counter, by V IZ8 Date: �oZs• 03 Contractor, designer, owner, was advised of the abve d y ❑ phone, mail, ❑ counter by Date: Plans reviewed by: mte Date: Plans approved by: Date: Z• 0 Structural reviewed by: Date: Structural approved by: Date: Note transfer by: Date: Yellow: Building Division 1 E.WUS9 ONLY Ploy Plan Attached 1rlooa Plan Attached sm� to 8.0/0 TO: Building Department FROM: Environmental Health SUBJECT: Sanitation Clearance Ow er Location AP# Plan Approved fo • Sewage Disposal Water Suppl Publi Private Well �ks ClgarVice_fq welling. Other ` Hold final for: Final clearance"O.K. for: NOTE: «. Enviro mental dealthSpecialist Date 8/96 ... .. ... ... .. ... ... ... ... ... .. .. ... .. . . .. ... ... ... .. ... ... ... ... ... ... ... ... ... ... ... ... . . .... ... ... ... ...... ... ... ... ... ... ... ... ... ... ... .. ... ...... ... ... ... ... CU op- -ARrA ti In In 0) AA S14,0 E: 0 w LL cc OD CS) (1) 0) m i rL C6 w LL vie alti ,�ronmental -C-.)ur-fy b n-- ital Health 2L f, Ico, CaliforniaIA� .NAM fir: P POESS: 14 713 -DURAME NJ ' 3o -b3 Aft FLEE7VVGl7D I - =- - �� SuncreSt Series Model 45138 R 3 Bedrooms • 2 Baths • 1,350 Square Feet ISC�i0��7CT�E3i� r.: ��_ // �7 rrrrr___�uMOV! i �roMum" 52M BEDROOM 09 DfNINO tas•xs•ro AREA ry _ K__ LIKNO ROOM b�2 At7• -10' wnvironmentai HealbL 0 C T - 1 2003 rhico, Califomia OPT, DEN #2 ra-s•xs-Io• OPT STUDY taa•xs-r0• OM DEN i_ ,arx rr•ur' PZL _ OPT 9ATH OPT. CORNER DAY OPr.RECESSED Fleetwood Homes rese(vres the right to change colors, prices, specifications, models, dirrensrons and materials %Whoot notice. Rendering and diagrams are meant to be representative and, in keeping vAth Fleetwood's policy of constant e;pdating and h-gyovement, ray vary from the actual home. AU dimensions are nominal and approumaled. Square footage is measured from exterlor wall to ex',erlor wail, and s an approximate fipere. Length inikated in floorplam is ' t'ou brKA only. The length of the hitch is not included. (Add four feet bD arrive_ at transportable length.) Ask your retailer for specifics. OWNER COUNTY OF BUTTE DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE, OROVILLE, CA 95965 TELEPHONE (530)538-7541 SCHEDULE OF RE4fEIPT OF FEES --- rsatance Lue..................... . 3 --4-^ --- Additional Fees Due........... $ A.P. # e 5>- 3M . ® 6% DATE 1 • S • L /RE EIPT # DATE REC. --- Revised Plan Checking Fee.... SCHOOL DISTRICT FEES (paid at School District Office) (form available after Plan Check) . -40 /P�e 3. SHERIFF FEES (paid at B 'lding Divis��� �� ._�0103 Residential............ � X $360.00 = nits Commercial (sq. ftg.)..... X $0.03 = $ Sq.Ftg. 4. URBAN AREA FEES (paid at Building Division) Residential (per unit)..... X = $ _ # Units Amt. Commercial (Sq. Ftg.).... X = $ Sq. Ftg. Amt. 5. RECREATION DISTRICT FEES (paid at Recreation District Office) (form available after Plan Check) 6. THERMALITO DRAINAGE DISTRICT FEES $510.00 (paid at Building Division) 7. SRA FIRE INSPECTION AND PLAN CHECK FEE $89.00 (paid at Building Division) 8. WATER TENDER FEES BATTALION # $200.00 (paid. at Building Division) 9. NORTH CHICO SPECIFIC PLAN (paid at Building Division) Residential Zone X = $ Zone # Units Amt. Commercial (sq. ftg.) ......... X = $ Sq. Ftg. Amt. 10. OTHER At time of permit application, I s advised the above fees are required to be paid prior to issuance of the permit. These fees may be changed during the an ecking nrq ss. APPLICANT DATE Pursuant to Government Code Section 66020, you are hereby notified that items, 2, 3, 4, 5, 6, 8, 9, and 10 above may have been imposed on your project. You have 90 days from the date of approval of the project or from the imposition of the above mentioned items during which you may protest. The requirements for a protest are specified in Government Code Section 66020(a). Original -Building Division Yellow -Applicant Pink -Owner (rev. 2/2003) I BUTTE.COUNTY SCHOOLS IMPACT FEE,CERTIFICATION FORM (One form per Bulldi4f School District r (� /t U Building Department No. A.P. Number Obs' 3OQ Oma' O0 /�'J Jurisdiction: city County Property Owner Property Location/A( Subdivision Lot No. .................................................................................................................. Residential Development 's Sq. Footage I No of Living Mobile Home Addition/ *Supplemental to (Group R) Units Installation Conversion Permit # '(No foundation inspection)':. €................................................................................................................... Commercial/lndustrial New Addftion 0 Sq. Footage (Including Exterior Areas) 7,Roofed 03 Date (Floor Plans reviewed by School District Personnel) 43 - lig 1 District Identification No. f, ,{ •� School District certifies that42 < (Applicant) (Street, Address) �•7 ' (Phone Number) (City) has complied with the requirements of Resolution No. representing /3-D square feet. .R., School District Representative ,'Paid by Check # / Llv� Remarks: (State) (zip by payment of $ AB 2926 $ FULL MITIGATION $ Date Notice: You may protest the imposition of the fees identified above by submitting a written protest to the District, in compliance with Government Code Section 66020(a), within 90 days from the date fees are paid. Failure to submit a timely written protest will prohibit you from challenging the imposition of the fees in any court action. If, subsequent to the School District Representative signing this Butte County Schools Impact Fee Certification Form, the School District is notified by the applicable Local Planning Agency that this project is being reviewed under the California Environmental Quality Act (CEQA), this project may be subject to additional school fees to fully mitigate its impact on the school district's schools. White (applicant), Yellow (building department), Pink (school district) feeform.xis (10/98)dmm 1 M NTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION County Center Drive - Oroville, California 95965 - Telephone (530) 538-754 PER Nc APPLICATION AND PERMIT KJYBEA ob S - "3 0 - 0,0,em'."° BUILDING PERMIT TE.EP ONE SO. FT. OCC. BUILDING VALUATION Ens - N r i % b v TELEPHONE rw.croRr Nue: 1;n 1 -1.0,') L- TMcsORS wNN3 ADDRE6e 3 o y e s� !✓A ,r, ,A �£ I c. u�+DER Fireplace jos "rARNM "DDS Total Valuation TS UCDGE N0. Erin Fee S 2D.00 OR D1r1MEEA Permit Fee S �- DR ptBwED:S ADDS Plan Checkm Fee S. G y . Energy Plan Checking Fee S Z-j--*L,0Vz eg 'PSG -A v i ,A PERMIT FEE MAPPLUMBING PERMIT Firing Fee 20.Do - • �� - -- -----. - Each Tr USEOFSTRUCTURE Solar or heat pump water heater 23.DO L73Duplex-❑ Nbbitehome- 8k Other Water p g 15.00 --� Veiny Each gas water heater or vent 15.00 TYPE OF WORK Gas PIPIng System t - 5 outlets 15.00 AddBon ❑ Remodel ❑ LaMes ❑ Instdainn 011ier ❑ Bulfing sewer 15.00 r mobile Home S G W @20.00 escribe Work r..E� `^�^FA v-�'1/��?�� }} p��� p✓� FaW rY-% i) PERMIT FEE S Dow OR LE= S ELECTRICAL PERMIT Firing Fee 20.00 Main Service Mk OA e� 23.DD Maur service 2=4 To ,00w. 46.00 /� NEW w,sr ( owE31++o occur. 3.5a FL, Bib %o X O H L/ OR R ObO D. l i /1LL. E1hS @7.50 POWSi APPItR4717S i SMCiLE 011n.ET CI0. mry�-� Ex. Ocar . ovnzr oA Pwruma eon ® so . Ex. Ocar . o ro E& S.OD • ^i\�> ��(� Temporary Service 23.00 Mobile Home Facilities 2D.00 �Y1!'►1�' •�ir�i � � _ e Id6se. Whin 23 D S PERMIT FEE _ b ME Firing CAL PERMIT ring Fee 20.00 Sar I f T Heating Cooling Hood Ventilaton PERMIT FEL: S Mobile Home Installation Fee S Energy Inspection Foe S T� �� �` `°N�' t TO AL FEE $ wt I►l O COF ' B. • n � r This permit is hereby issued under the applicable provisions of the Butte County Code end/or Resolutions to do work i %� mdicaled above for which fees have been paid. rCc" By Date PERMIT EXPIRES ON AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVH.LE, CA 95965 ER003—el070367 Recorded Official Records County Of BUTTE CANDACE J. GRUBBS Recorder ROSEMARY DICKSON Assistant 01:51PM 07 -Oct -2003 REC FEE 7.00 CONFORM 1.00 nark Page 1 of 1 AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgement to be recorded prior to issuance of a building ' permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural-c-hemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as following: Lot 228, as shown on that certain Map entitled, "SIERRA DEL ORO ESTATES UNIT NO. 3", which map was recorded in the Office of the Recorder of the County of butte, State of California, on June 3, 1968, in Book 35 of Maps, at Page(s) 27, 28 and 29. ,, Date )L� - C - 0 3 PROPERTY OWNERS: "NO .�.� LA State of California County of Butte On /z�,D96& before me, personally appeared /,Y/L//L/ 6-/4 pgsonally4ff me4er proved to me on the basis of satisfactory evidence) to be th erso s) whose am s)Cak/are subscribed to the within instrument and acknowledged to me that�Wshe/they executed the same infer/their authorizeq capacityxies) and that byd!Dher/their(gi a s) on the instrument, th erson ) or the entity upon behalf of which the erso s) acted, executed the instrument. WITNESS my hand and official seal. SignatureM. SUSAN GLATZ % mac/ Seal: ®���,� COMM. # 1280664 D NOTARY PUBLIC-CAUFORNUI APN 065-380-007 COUNTY OF BUTTE �—� Comm. Expires Oct. 16, 2004 BUTTE COUNTY OV 6Fp� o 0 AGRICULTURAL BUFFER p o -- _ =�z o UNUSUAL CIRCUMSTANCES REQUES . Q h p4Akc� cOUN'�y Butte County requires a 300 foot buffer between neig A- agricultural operations and a residence. This dimension is based on environmental assessments and studies. The Agricultural Commissioner may identify unusual circumstances where the 300foot buffer cannot be met on existing parcels. This exception is not available for lots being divided or subdivided. Applicant must complete the following and return with the required site plan to: Development Services Department, 7 County Center Drive, Qroville, CA (530) 538-7601 Name: -Phone: Assessor's Parcel Number: _ 010 S - 3$ ° - 0109 Reason you believe you qualify for the unusual circumstances exception: \,o -s s �� coo * s ro"T P --;-: .',-r -3,0' 5 *.--T (S-A c,X 5 Applicant's signature `1-4�—v3 Date UNUSUAL CIRCUMSTANCES DEFINITION: An exceptional or extraordinary condition where the existing lot size or shape or an existing improvement (well, septic systems, structures etc.) does not allow for the standard condition of a 300 -foot buffer zone. I SITE PLAN REQUIREMENT: submit 4 copies with this form Refer to the Site Plan Submittal handout for specific requirements ........................................................................................................................... For Agricultural Commissioner office use only: (to be completed after submittal) DISCRETIONARY PERMITS (Planning) MINISTERIAL PERMITS (Building) ❑ Exception Recommended ❑ Exception Granted with the ❑ Exception NOT Recommended following conditions: Reason/Conditions/Specific setbacks from adjacent agricultural operations: Agricultural Department Signature: Date: YMC 4/20/03 National Pollutant Discharge Elimination System SWPPP Non -Certification for Project # County Storm Water Permit Compliance (NPDES) Phase II & for Butte By signing below, I, the project architect/engineer of record, indicate that I am aware that a construction project that disturbs more than 1 acre of land requires a Construction Storm Water Permit from the State Water Resources Control Board. I, additionally, understand that it is the project owner's/owner's agent's responsibility to submit a Notice of Intent (N. 01), a Storm Water Pollution Prevention Plan (SWPPP) and a fee of $700.00 to the State Water Resources Control Board to obtain such a permit. I, further, certify that this project will not disturb more than 1 acre of land. I have also reviewed the Best Management Practices Handbooks, California Storm Water Quality Task Force, Sacramento, CA. I certify that appropriate BMPs will be implemented to effectively minimize the negative impacts of this project's construction activities on storm water quality. I acknowledge that it is my obligation to make the project owner and contractor aware that the selected BNIPs must be installed, monitored, and maintained to ensure their effectiveness. If, at any time, site conditions and/or observations by a County official warrant reevaluation and revisions of the chosen BNIPs, the appropriate changes will be made without unnecessary delay. I am aware that failure to properly implement and maintain the BNIPs necessary to prevent the discharge of pollutants from this project during construction could result in significant penalties and/or delays. Signed: Title: Date: By signing below, I, the project owner/owner's agent, certify that I am aware that a construction project that disturbs more than 1 acre of land requires a Construction Storm Water Permit from the State Water Resources Control Board and that it is my responsibility to submit a Notice of Intent (N.O.I.), a Storm Water Pollution Prevention Plan (SWPPP) and a check for $700.00 made payable to the State Water Resources Control Board to obtain such a permit, if my project disturbs more than 1 acre of land. I, further, certify that this project will not disturb more than 1 acre of land. This document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified individuals properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons directly responsible for gathering the information, I certify, to the best of my knowledge and belief, that the information submitted is true, accurate, and complete. Signed: Title: Date: NPDES & SWPPP Non -Compliance Certification Draft Butte County Stormwater Plan SITE PLAN REVIEW APPLICATION Date: -1— AP# Obtj ?jSQ- D Permit Number (if applicable) D3 - 2- S L) Bin Number , APPLICANT INFORMATION Parcel Size: Owners Name: )Ce rr- , �~)1,� ri m n!3_ � Owners Address: L" B; A V E Q-\ UG_1Z S 1 D-6 CA 9 2', 0'4 Telephone No.: Situs Address: Proposed Use: Residential ❑ New Single Family Residential ❑ Single Family Addition Mobile Home ❑ Residential Accessory ❑ Permanent Second Dwelling ❑ Temporary Mobile Home (Aunt Minnie) ❑ Temporary Travel Trailer ❑ Multi -family Non-residential ❑ New Commercial ❑ Commercial Addition ❑ New Industrial ❑ Industrial Addition Other 2 Septic ❑ Agricultural Exempt Building ❑ Other: ❑ Single Family Remodel ❑ Commercial Remodel ❑ Industrial Remodel ❑ Well ❑ Agricultural Buffer Form ❑ Applicable ❑ N/A Brief Explanation (if necessary): 2-0 --) se -1 fa AG1< -rrzz ylt-, 1 DO NOT WRITE BELOW THIS LINE DEVELOPMENT SERVICES INFORMATION (For Staff Use) i ❑ Approved ® Conditionally Approved ❑ Resolve Problems Prior to Approval ® Site Plan Stamped Approved By Date Page 1 of 5 ALL ITEMS CHECKED APPLY TO THE PROPERTY Parcel Is In: ® Snow Load Area: 2S0 T 'C-) 3 ' ❑ Land Conservation Act Minimum Acreage: ❑ Verify residence can be built per contract ❑ Nitrate Action Plan (See Environmental Health for standards) ❑ Watershed Protection Overlay Zone (See attached standards and requirements) ❑ Expansive Soils (Test for expansive soils and if verified proper foundation design required) ® SRA - (CDF to determine specific requirements) ❑ 100 -Year Flood Plain: (See attached) • Flood Zone: X • Flood Panel No.: 0 y0 o� Index Date: ❑ Sacramento River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ Feather River Reclamation District (Approval must be obtained from the California Reclamation Board) ❑ North Chico Specific Plan (See Development Fees Section and attached standards and requirements) ❑ Chapman/Mulberry (See attached standards and requirements) ❑ Cohasset Area (See attached standards and requirements) ❑ Grading Zone (See attached handout) Use Requires: ❑ Use Permit ❑ Minor Use Permit ❑ Administrative Permit ❑ Minor Variance ❑ Variance ------------------------------ ❑ Detached Building Use Form ❑ Encroachment Permit ❑ Agricultural Worker Affidavit ❑ Agricultural Acknowledgement Statement Zoning: 2 T — 1 Applicable Building Setbacks: ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 \. Zoning Code Streets & Highways Fire Prevention Subdivision Map Front p C� /I— Side 2)zj Side Street Rear Height Waterway N/A N/A N/A ❑ Setbacks drawn on site Plan. ❑ CDF approval needed for encroachments into SRA setbacks. Page 2 of 5 \. IF f Applicable Development Fees: Standard Fees Amount Formula ❑ Fire ❑ School* ❑ Parks/Recreation ❑ Roads ❑ Sheriff ❑ Drainage ❑ NCSP/CSA 87 ❑ Chico Urban Area — Road ❑ Thermalito Drainage Area ❑ Thermalito Urban Area ❑ Other Subdivision Map Special Fees ❑ Water Tender ❑ Road Improvement ❑ North Oroville Area ❑ Other (per map) * Check with school district to verify actual fee if pre -application review. A final determination will be made at the time of the building permit. Parcel Created By El Deeds: Date of Creation: Legal Access Provided: ❑ No ❑ Yes Deed of Reference: Legal Access Required ❑ No ❑ Yes Parcel Frontage on Publicly Maintained Road: ❑ No ❑ Yes, Road Name: Complies with County Standards for Deed Creation:[] No ❑ Yes Comments: ❑ Parcel Deemed to be legal ❑ Verify Legal Parcel ❑ Verify Legal Access ❑ Provide Deed of Creation ❑ Obtain a Certificate of Compliance ❑ Obtain a Merger ❑ Obtain a Lot Line Adjustment ❑ Comply with Old Subdivision Lot Ordinance (Maps recorded prior to Book 17 of Maps Page 23). ❑ Construct road to: ❑ Meet Parcel size required by zone ❑ Meet current Environmental Health Department requirements Page 3 of 5 IN Subdivision Map/Parcel Map: S) Ct2p- P !�-e 1_ C>2oS ; - # '5 Map Date of Recording: 3- L. - 6 8 Lot: 22 8 ❑ Use Permit/Minor Use Permit Permit Number: Book: -� 5 Date of Approval: Page: 2:-) 2 Parcel Map/Subdivision Map/Use Permit Conditions ❑ Comply with the following Conditions of Approval: ❑ Attached ❑ None ❑ Meet the Fire Safe Regulations of Butte County and P.R.C. 4290 ❑ Automatic fire suppression ' sprinkler systems shall be installed in accordance with the National Fire Protection Association Standard for installation of sprinkler systems in one and two family dwellings and mobile homes, NFPA Standard 13D, unless a pressurized community water system, with hydrants that meet the Fire Department specifications, serves the parcel. ❑ Wood stoves and fireplace inserts shall be EPA approved and designed to meet the emission requirements of the California Clean Air Act of 1988, as amended. ❑ Provide an erosion control plan for building and land disturbance. The Erosion Control Plan must be prepared by a registered civil engineer or other qualified professional and be submitted to and approved by the Department of Public Works. ❑ In lieu of a pressurized water system or water storage tank, payment into the appropriate Battalion Water Tender Fund may be required. ❑ Measures shall be taken to control fugitive dust emissions from all driveway and other civil construction associated with residential development. Approved dust.control measures are found in the fugitive dust control plan for the site approved by the Butte County Air Quality Management District, a copy of which can be obtained from the Butte County Department of Development Services, Building Division." ❑ Engineered foundations are required. ❑ Class A roofs are required. ❑ Property owners responsible for road maintenance, and stop sign maintenance. 0 Page 4 of 5 ro 1 '00: Ile -wo 10 OA CY, 114 I'M N s4 00 0. D rr� , �° p ' Q o p 61 . J qN, RN kWU Cq Ifo o,��%�_� a o a ;g -oO, :!7 aI fo N ,�9ra.� � .o � a,: ,89i��� � of I� N aM��:� IN o -/,F 7 pal 674?1 a6 p a OOA\3-:S 0 Zi AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE, CA 95965 COPY of Document Recorded 07 -Oct -2003 2003-0070367 Has not been compared with original BUTTE COUNTY RECORDER AGRICULTURAL STATEMENT OF ACKNOWLEDGMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8 of the Butte County Code required this acknowledgement to be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of this property may be subject to inconveniences or discomfort from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occasionally generate dust, smoke, noise, and odor. Butte County has established agricultural purposes and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as following: Lot 228, as shown on that certain Map entitled, "SIERRA DEL ORO ESTATES UNIT NO. 3", which map was recorded in the Office of the Recorder of the County of butte, State of California, on June 3, 1968, in Book 35 of Maps, at Page(s) 27, 28 and 29.' Date_ JZ - L1 PROPERTY OWNERS: ,State of California County of Butte �On J pOJZ before me, personally appeared IIy�.,/ -15-7,,4 p n4e awe-(er proved to me on the basis of satisfactory evidence) to be th erso s) whose am s i-9/are subscribed to the within instrument and acknowledged to me that( she/they executed the same ind0her/their authorize capacityl(ies) and that by ffi/her/their(9i natu s) on the instrument, thej erson �s) or the entity upon behalf of which the erso s) acted, executed the instrument. WITNESS( my hand and official seal. Signature ���• ;21/ Seal: M. SUSAN GLA COMi� GC ®' NOTARY PUeu126 ALIFORNIA X APN 065-380-007 COUNTY OF BUTTE COM -In. Expires Oct. 18, 2004 FLEE7W()OD. sunbreSt Series Model 451 B 3 ?-Bedrooms • 2 Baths • 1,350 Square Feet -., �, c �1. � .£ � � �_ _ " ., , �_ � ..x� 7n :;�, a,�- r:-� i -w y'.. T �y s'., -r ,.y ,; � :.,. or,•: -1 _ �`''. �. <'--: � ..��.�" _'�� '.. S. e •_.;,"-�,it �Ft;. .:nF' . ' �'��,�-� .aav:>.' , � s�'�,!s�',� ���„�"..* �. "�t� .. �"�r.°_s��"� �+.a h ^���+; ' 3 ,�",�. �, r e WALK-IN cLO—S� OoDsNo2 sfE—rJ OPT; BATH `♦ ♦ARCH ....... ♦ J� I DPL S.G.D. i ! L ElI i i I MORNING ! ROOM' ' OPT, STUDY DINING los°xsfo^ AREA �y 10'-5"X *V" TIT ! ! - ' `♦I ! \ - !� \`` ARCH / r' 1 aaols!r ' 0 - SHELF/OPr.. OHO ` GABLE `\ DORMER MArPTER \ - — O' 1 M' BEDROOM / LIVING ROOM \\��; BEDROOM #2 \\y OPT. DEN BATH `'"xis' -0" \ fa -2"x10'-10 i. to -2"X12' -f0" , � ! • ` Del. DOORS - ENTRY OPT, CORNER BAY OPT. RECESSED ENTRY Fleetwood Homes reserves the right to change colors, prices, specifications, models, dimensions and materials without notice. Rendering and diagrams are meant to be representative and, in keeping with Fleetwood's policy of constant updating and improvement, may vary from the actual home. All dimensions are nominal and approximated. Square footage is measured from exterior wall to exterior wall, and is, an approximate figure. Length indicated in floorplans is floor length only. The length of the hitch is not included. (Add four feet to arrive at transportable length.) Ask your retailer for specifics. CDF FIRE SAFE REQUIREMENTS 6 s-'3�0--0 `? N -2s3� Z "J'/ AP# PERNIIT # NAME Under authority of PRC 4290, the following checked items are required by the Butte County Fire Department and are made a part of this permit. These requirements are minimums and will be superseded by Butte County local regulations which equal or exceed these standards. Field inspections will be made by the Butte County Building Department for compliance. [X] 1272.00 Maintenance of Defensible Space. To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access and utilization of the defensible space provide for in these standards, annual maintenance must be provided for by the land owner. Driveway Standards [X] 1273.02 Surface. All driveway surfaces and structures (bridges, culverts and other appurtenant structures which supplement the roadway bed or shoulders) shall provide unobstructed access to conventional drive vehicles. Including sedans and fire apparatus weighing up to 40,000 pounds. [X] 1273.03 Grade. Not to exceed 16 percent unless paved. 1273.04 Driveway Radius IN 1. No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of feet shall be added to curves of 50-100 feet radius; 2 feet to those from 100- 200 feet. IN 2. The length of vertical curves in roadways exclusive of gutters, ditches and drainage structures designed to hold or divert water shall be not less than 100 feet. [X] 1273.05 Turnarounds. If required, will have a minimum turning radius of 40 feet from the center of the road. [X] 1273.06 Turnouts. Shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. [X] 1273.10 Width. All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of 15 feet along its entire length. Page 1 of 3 cot JIV � � -riv AP# PERMIT NAME [X] 1273.10 Turnouts. Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the midpoint of the driveway. Where a driveway exceeds 800 feet, turnouts shall be provided no more than 400 feet apart. [X] 1273.10 Turnaround. A turnaround shall be provided at all building sites on driveways over 300 feet in length and shall be within 50 feet of the building. 1273.11 Gates IN 1. Gate entrances shall be at least two feet wider than the roadway it serves. IN 2. The gates must be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that roadway. [X] 3. Where a one-way road with a single traffic lane provides entrance, a 50 foot turning radius shall be used. Fuel Modification 1276.01 Setback for Structure Defensible Space [ ] 1. All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from all property Q` lines and/or the center of the road. [�J 2. For parcels less than 1 acre, local jurisdiction shall provide for 1 the same practical effect. See other requirements on page 3. [�] 1276.02 Disposal of Vegetation and Fuels. Disposal, including chipping, / burying, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction and fuel modification shall be completed prior to completion of road construction or final inspection of a building permit. Page 2 of 3 1 AP# 0 3-ZF3� PERMIT # Other Requirements ( ) If Building Setback is 15 to 30 Feet: - Class A or B roof and Enclosed Eaves NAME ( �] If Building Setback is Less Than 15 Feet- Class A or B Roof with Enclosed Eaves and: Choose any 2 of the following: - Metal or no doors on the side toward property line with insufficient setback - Interior automatic fire sprinkler system per NFPA 13D - Glass area not to exceed 10 % of wall area toward property line with insufficient setback - Siding from the following list: Stucco — 3 coat Hardi- Board or Plank Masonry Masonry veneer Metal Other Butte County Fire Department approved materials Date Signature ell Page 3 of 3 2. Assessor's Parcel Number: 01,0 S _ 3�0 - ooh 3. Installer's Name: L 4. Is the site currently under permit? Yea( ] NON Permit No. 5. Is the site an existing site? YesP<] No[ ] (If yes, firrni 6. What is the electrical rating of the mobileir slr two plot plans). ! ome? \ _�]Peres. i 7. What is the mobilehome site circuit breaker rating? 8. What is the electrical rating of the mobilehome site? Z-oa i f 9. Is the main service remote from the mobilehome ? Amperes. the rating? site. Yes[ ] No If it is, what is Amperes. 10. Is there any other electric load to be served by the mobile! (i.e. well, garage etc.)? rorne site electric service Yes[ ] No[>,Ifyes, please identify tine load and size: a) The mobile borne site: Load - b) The main service: Amperes- Load- Airrl.reres- 11. Type of gas service at mobilehome site: Natnra!(I r. ] ' opaneM None[ 1 12. Size of gas ;, pipe at tile me site e rTrobilehofrom . tank: � �,y inches. the meter or 13. What is the gas pipe length from tine meter or tank to the mobilehome? 14. What is the mobilehome gas demand? *(This information is not required if the pipe len �i B•T•U tl.* less than 50 feet on propane). g r is less than 6 feet on natural gas or May 1995 PROCESS THIS u� ;"�Ml'LETI RMI'I' AI I LIGATION Ua= COUN1 4:3 ��D91�G DEPAR11 K4f-:.,. V 1 J 8.5 i:3:S::iy::::;%2:i 1 li JE... • a�:.It:�.. Mobilehome Manufacturer: Milittfacture Year:Z� _ If other than single wide, fur;,Model Number:_ "1S I "3f Width�b' �� (ft.) Length: 50 �•f .[i.) Tagalong or Expando Size On all mobilehomes manufactured • after October 7, 1,973, furnish manufacturer's installation manual and structural setup sheets.. FOOTINGS: Wood pressure treated or foundation gradej>Q :Other: SUPPORTS: Concrete blockM Other: Provide Tie Down Specifications for all Mohilehomes: Pier Footings Sizes anal Lochliou " SINGLE. w1UE MULTI-wlnE Line 1 {—Line 1 Line 2 ...................................................................:............................ Line 2 Main Beams Line 2 ........................... ............................................. "ine 2 Lute 1 {— Line 3 V,,- Line 2 ................................................................................................ Main Beams .......................................... j Line 2 Line I ...................................... Tag or Ttiple ine 4 {—Line I I Line I Piers: Size minimum: �) x Spacing maximum: " From ends-maximun ` Line 2 Piers: Size minimum: [11—] x Spacing maximum: 110o. From ends -maxis uIII- p " Line 3 Roof Loads: s,p ,�}8'�gD 4&X30 Size minimum Location (frons fi-ont): Line 5 Roof Loads: Size minimum: Location (front front,' Line I Openings Size minimum: x ]" Each side of openings with width over: ` Line 4 Piers: Size IninImW): ] x Spacing maximum: From ends-nlaxinlum. ` Kz' 2'I s OVL1t "IUILDING DEPAFjMfz—:.'a. '. pV" �r6 T? i n .a ,� Lr ky ►e � �l r,TE COUNI r 1, ///j� `�\ eslC•i tti 1 \� m 1 ' .te j V}irj �j U L ] =i ._ 1 1 Ili i ch .11� SS311 a li �,. V ..4...`:vo 5Ti , a_• m O U w � � Nash dU 3gIB lL3t1►Al � � $ t4 to No JJAUM 3dY.1 J.VdN �7hQ Inn nF4 nm ul-1.1 1.1,) In-1nM 'C, ll lnll nnnM i cl i t.l Illi I r': r n r �A9p Ci to to ato n Z m k'' 1� %' rcx C- N APPROVED DIn :CUti ".! U -r) ,� Lr ky ►e � �l r,TE COUNI r 1, ///j� `�\ eslC•i tti 1 \� m 1 ' .te j V}irj �j U L ] =i ._ 1 1 Ili i ch .11� SS311 a li �,. V ..4...`:vo 5Ti , a_• m O U w � � Nash dU 3gIB lL3t1►Al � � $ t4 to No JJAUM 3dY.1 J.VdN �7hQ Inn nF4 nm ul-1.1 1.1,) In-1nM 'C, ll lnll nnnM i cl i t.l Illi I r': r n r �A9p �- S6T, Z_OF 3 BUTTE COUNTY PROPERTY RECORD Assessment Fee Number r Book Page/Block Parcel \ D K _ _NAME NAME SITUS/ �/ 7 / L� rct �+ e �^- C_v City ❑ County Assessment Year 20 / 20 03 20 o3 20 20 20 ZONING UTILITIES -SITE IMPS. Date�/-Zs -o� -3 3-i0-03 Electricity: Yes F1 Telephone ❑ Appraiser Gas: Public ❑ LPG ❑ None ©' Use Code Sanitary Swr: Public EDIndiv. Dwelling Units 1 1 Street: Conc. LJAsph. [Dirt El Gravel ❑ Building Class Li C/-/// G�C�/�J Street Lights: Yes ❑ No d Bedrooms C & G: Yes ❑ No p Baths Sidewalks: Yes ❑ No Q Effective Year SITE TOPOGRAPHY Area of Residence Car Shelter Yes [--]No ED Yes F] Nola Yes ElNo a Yes❑ No ❑ Yes ❑ No ❑ Yes ❑ No ED Level Q Rolling F-1Other❑ Slopes: Up ❑ Down ❑ S -S ❑ Misc. Buildings Yes C1 No ❑✓ Yes ❑ No �7 Yes ❑ No Yes ED No ❑ Yes ❑ No E] Yes E:1 No ❑ Grade: At F-1 Above E) Below ❑ Pool Phy. Char. Checked ❑ Checked ❑ Checked Checked ❑ Checked ❑ Checked ❑ View: ❑ Of: S MARKET DATA WATER GPM: Depth: Comparable 1 Public Q Well ElDitch ❑ Comparable 2 Supplier / ot. to Aerial Photo Year Comparable 3 Sale Date/Price PRIMARY BASE SECTION Topo Map Year Soil Name Index Acres Base Year p/ ' X05 uo3 Event Date //V-00 07-25-02 Land /. o00 25ooa 2�Gov Structural Imps. 8 o00 Growing Imps.x-00-0 Fixtures Personal Property SECONDARY BASE SECTION Avg. Soil Rating LAND REMARKS: Base Year Land Type: Lot [.,I H/S ❑ Acs. ❑ Event Date Size: /r-eI-E q AL Land Description: Structural Imps. Growing Imps. Fixtures Personal Property Tnhl )UNDA ON LI 11 TING BUILT-INS FIREPLACE ROOM AND FINISH DETAIL e, —N -R. d urate•ler —1 "Slab Few Avg. Moray Fair Avg Good Kilchen Fon Loca lions _ Room Floors Walls Cpl. Nw, lino S.R. 'Pt, Pan. Ceilings S.R. PI.TA,, Fc. Hood Ronge Molal Brick Slone Morble SlorY' 1 7 B All Rotes 220V Oren Rnisod H—th Entry JII SPo<. Rhoos. Doubla Ovens Woll Hill. living — - _--- Elo<Ironi< Oven Free Slonding DinlnR -- VE STRUCT. HEATING Drop-in R 6 O HeaNlaler Fomily -- C. BIk. For<oJ C-1-1SIIJo-in R go Flonk Shelves Kllchen AJobe Wall Grovily Garbooa Disposal Dbl. Opening B -1,1.0i Con,_ -_— — Floor Perim. Dishwall— Two Story Bedrooms - Rodian Coiling 11.410-1- - :XTERIOR Ele<. Blbd. Inler<am GARAGE Ponal " Shingle Gas E—d. 'Slot. Breaklasl Bur Alloched Wilily KITCHEN DETAIL -- P. P. V—.. Onon Delochod Arhus Ecorse. Wel Oor D-10. Ca binaN N.W. O.P. Plywd. Metol Spec. Nol. Sl ainnd I I Al.— 770 V. 6.110StnBla Dr. lid. 8 Cab. Top file Mk. lino. Splash I I R 6 C E G A F P stele _ COOLING Blcndor -- Corporl _ BATH DETAIL bds. _ Robin, Conlrol B8110CorpoH Finish Fieluros S , i k _ _ t Evap. — Root Uesk Electrlclly • Fl,. No. __ Floor - Wolls Toila . lova fub Si.SIO:T. G.d. --Finlsh Pullman Muc. Engrd. Woll O.• H. Joorlil-- _ /INOOWSIF-- -T—.•. Wind. Romolo C-4.1 M. — Wd_ oo - _ _ — Fin Nhed _-Stool Wlr. HIr. Gals, . FinNhod _ Al... _ _ MISCELLANEOUS STRUCTURES b% lil7q L..d.d $DATE:_ __ APFR ISERFdln. �'�� `('yf1 IG ZgI% (u ¢ OparuloC _ __ Ilom _ -_ Fl,.Esl. Int. Root Age Sl.. S/S.F. --p�„ % Gd: `RCLND` S/S.F, bd. RCIND S/S.F. % Gd. RCLND -- 1�)uel_�!.__ .L�IyN•., c:7—��f Serif .i:'Flr, �I ., I f -rt r: lar. 30 � � f6is:' iti"�' •v — �, t�CIO 6 1�1�0 S'v 3" w _I9S� 729 ROOF r- c .•r 1 .'. I SSQi �%G 49sG Goble — TOTAL UU 3 REMARKS: CALCULATIONS: are Eav le L -i e-Shinglo .� e -Roll I - id GrayaI llf rCt r SHEET OF SHEE ,; DOPESS - nr1C119r/Dr1r)A( rip Rl/ll f1ll://i.S _Ids Structure Size Four, d. ✓`v- !Mall 3 ' - Exterior Roof Type Coyer Floor & Inferior Detail Second Story or Loft Year IEst.1 Built Life Na. ter' 120 2 �uv 1 ?:. tEll — I / I �".i L' Vl i11 111 � �i�� ��S'J ,5�,. �rrl^l\��: �t�.t•�r��cc~LA�S ✓-)V, OCA�C _ _ r�. G- �, = c%�� E—I'R� 6iiLe, = C�C�� ^c. ! ?'.r.VJt 1�<_: Cei� -- F'r q?D . n i S`uF e7 =. L.. �. � = ( -P, L G- El') V �% Total c r a (r-Q1� > i. E r i, i�r L I.N._' Y, C L I G i' Unit Cost I COSP ° /e go 19 r?. C. Rl. li( Un ! S` �A ,Ou, I 19 C. il. r /O 1. �. y oI %F, Un/P ost Coit (o% R. C. M. Unit R. nl S R. Cost % I R. C. /i/ /�r r _ I i - COMPUTATION L/_ 19 I 19 ,cppra/ser-cure I 3/dg. Area Uni' cost /-• Cost /l/:-1 % rood , - R. C. N. 1 . lit. D. ���� Unit CosP .. -- - Cos; �`/° /?.C1lV I � ood L. n. D• Unit Cost Cost I v%� I �o�d R.C.P.! CostP I L. /�. D. Cost �° P. C./ Goo L. fl'. ter' 120 2 �uv 1 ?:. tEll — ,-- -1 I -- q?D i I ! Total (r-Q1� foo O Appraiser- Date Area Unit Cost I COSP ° /e go 19 r?. C. Rl. li( Un ! S` �A ,Ou, I 19 C. il. r /O 1. �. y oI %F, Un/P ost Coit (o% R. C. M. Unit R. nl S R. Cost % I R. C. /i/ /�r r _ I i I I I Toto! Ali 531-H 9-'46 ti. V w cl :L4 L4.14 FILE No.917 09/17 '03 AM 11:29 ID:EXECUTIVE HOMES FAX :530 891 8753 PAGE FL E E I WCOD. MR1140- LUM-11 Executive Homes . .. .. . .......... . ............. . . ..... .......... 3042 Esplanade ChIC0, CA 05073 530419-1-tiD02 - 600-340-0002 Fax 630.601-8783 E -infill: FACSIMILE' 'I'll A NSM ITTAI. BillLeveroni VAK 1411KIII19t: I)ATI I. ........... . GIthe VANY: . ... . ............. ................. ITAI. P40. 01'PAGM-i INCIAJIMA. COVIIII: .. .. .......... -- -------- .. .. ......... ......... .. . . 11110141! NIIAMIM: ...... ..... . ........ ..... .. ............... . ....... Y01111 11VI'VAIMIA! 1,411KIII19k: Cl III'('; vi,ri- ["A i;oit lwvirw F-1 VI I:ASI; 1:( IMMFIAT -XII 'I.VASI-'II1WI.Y 14.1 --AS)" FILE No.917 09'17 '03 AM 11:29 lD:EXECUT}VE HOMES FAX:530 881 8753 PAGE 2 ° ' o. soo v � lot 19--1 *zwe I'vq PS v 1� C!)5 v', o MGT�?G rF�, t % �, i iO i J. u /Z HOLI Al P/!"46' `M yA G - 1--,) 1 fi-PY-A U1o5 --�� 0/3 1 �7 -s' sE T g,,�ocA< vs, � S,p `M NA G -PY-A 0\05 — I C5) 500 iv �o e 4 Al e� �n Ci'J IbA ®PO,S'= r� if l l P//I, CT ,A -P -n 0105 - -,o or) vq alt` .t- wt, Oil Cd) APPROVED Envir County •--J' • n, ental Health i' Date ' Signature �, � rry � w Qom'• ^y+ � C ` � - 14rl MECHANICAL., AND Pl-Ut4"W'r4 �eCTRICA! N1� NOT PLAN C�ilw( CONSTRUCTION CURRENT ECI u SHAcLLCOM�C WITH UPCe ®'F NEiC, h j .` rr '•� I7 _z$3Cr i3U%`c: COUN U�Lt�IImG ®EPARTMEN, 4 P P R 0 V 5 -OTE: See the attached �Pl�tic�� �iAelSfi�IC��D�1 Sel-GE eXI-57-IN( PIAIC I Cl I d m ,AL1 G -A 1-,-')'� t r� I') 7j' Y'i 01o5 - '�'9 ID - '0 0'-) REVIEWED BY BUTTE CO. FIRE DEPT. , CALIF. DEPT. of FC° ESTRY approved as submit d [-approved with conditl S t (� U Xfi B`'I attachesh et. Signature ' to ALL STRUCTURES AND EQUIPMENT. INICL13DING OVERHANGS SHALL BELEAR OF ALL EASEMENTS: 9 SET BACK OF d�jFT/FROM THE SIDE AND _ ROM THE REAR PROPERTY LINES AND CT . t FROM THE ROAD CENTERLINE SHALL BE CLEA STRUCTURES AND EQUIPMENT EXGEP. eOR A 2 FT. EAVE OVERHANG. CA 0 -u C. to U.X C,7 V., M 0 - (P Z ell 0 CA 0 -u C. V., M 0 - (P Z 0 r BUTTE COUNTY BUILDING DTVI SICS-.il APPROVED (ov" ZAF cc) JOB: Kemp_Lynn Q LOCATION: Butte CO. MiTek© TRUSS ENGINEERING MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, Ca.95610 Phone:(916)676-1900 Fax:(916)676-1909 ► LUMBER ► HARDWARE ► STOCK PLANS ► CUSTOM DRAFTING ► TRUSS ENGINEERING ► TRUSSES ► PRE FRAMED WALLS 655 Cal Oak Rd. P.O. Box 1947 Oroville, Ca.95965 Phone: (530)534-0300 Fax: (530) 534-5269 WARNING: DO NOT CUT OR ALTER TRUSSES IN ANY WAY. WARNING: DO NOT STORE TRUSSES ON UNEVEN GROUND. TRUSSES REQUIRE EXTREME CARE IN HANDLING 'BUTTE C�� 13UILDING DVV � 4 f TIMBER r,-- PRODUCTS INSPECTION 105 S.E. 124th AVE. Vancouver, Wa. 98684 Phone:(360)449-3840 Fax:(360)449-3953 MiTek TRUSS SCHEDULE Tails ProjeCt: KEMP LYNN County: BUTTE Contractor: Endeavor Homes I Date: July 18, 2006 Roof: COMP Plan: Snow: 35# Drawn By: Mw Tail Cut: Plumb ®®_ 0 . ProjeCt: KEMP LYNN County: BUTTE Contractor: Endeavor Homes I Date: July 18, 2006 Roof: COMP Plan: Snow: 35# Drawn By: Mw Tail Cut: Plumb Lynn Kemp Endeavor homes 655 Cal OA KJ. Qroville, Ca. 95965 (530) 534-0300 (53o) 534-5269 Re: Kemp_Lynn 00 MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Fax 916/676-1909 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by Endeavor Homes. Pages or sheets covered by this seal: R22061857 thru R22061858 My license renewal date for the state of Califomia is March 31, 2007. �OQ?,pFESS/pN� ��r���R S. Ix C 046433 r.G. *\ CA17J-J1-V/ /* - l July 19,2006 Tingey, Palmer The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-2002 Chapter 2. J*b TNSS Truss Type Qty DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.46 R22061857 KEMI• LYNN A COMMON 13 =Rkeferenc.@ — 8-9 >999 180 TCDL 10.0 Rep Stress Incr Endeavor Hames, Orevllle, Ca., Matt Wilson N i 0.200 s Jul 13 2005 MRok Industries, Inc. Tue Jul 18 13.35.27 2C -1-0-0 8-4-14 12-0-0 17-7-2 24-0-0 25-0-0 1-0-0 6-4-14 5-7-2 5-7-2 6-4-14 1-0-0 Scale = 1:42.1 44 = 3x1 = e a 8-0-0 5x6 = 3x4 = "_0 N 1� LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.46 Vert(LL) -0.15 6-9 >999 240 MT20 220/195 (Roof Snow --35.0) Lumber Increase 1.15 BC 0.61 Vert(TL) -0.28 8-9 >999 180 TCDL 10.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.08 6 n/a n/a BCLL 0.0 Code UDC/ANSI95 (Matrix) Weight: 92 lb BCDL 10.0 LUMBER BRACING TOP CHORD 2 X 4 DF No.1 &Btr TOP CHORD Sheathed or 3-5-3 oc purlins. BOT CHORD 2 X 4 DF No.1 &5tr ESOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDS 2 X 4 OF Std REACTIONS (Ib/size) 2=140510-5-8,6=1405/0-5-8 Max Horz2=63(load case 7) Max Uplifl2=11118(load case 5), 6=48(load case 6) Max Grav2=1444(load case 2), 6=1444(102d case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/47, 2-3=-3066/115, 3-4=-2713/56, 4-5=-2713/96, 5-6=3066/115, 6-7=0/47 BOT CHORD 2-9=-101/2815.8-9=-1211919,6-8=-54/2815 WEBS 3-9=-656/134,4-9=-13/974,4-8=-13/974,5-8=-656/135 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS gable and zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) Unbalanced snow loads have been considered for this design. 3) Overhang has been design for 2.00 times live load + dead load. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard July 19,2006 Q WAItMNO . V*rVy bale. raramtU- an[ RZA/ NOTES ON THIS AND IJNC DED JQTER REFFJWNCL PAGE MU -7473 AX70RI Pili!, 7777 Greenback Lane �• Suite 10B Design valid for use only with Mi rek connecters. This design is based only upon parameters shown, end's ter an indivaluel bulling component. Citrus Heights, CA, 95610 Applicalsility of design peramenters and proper incorporation of component is responsibility of building designer- net truss designer. Bracing shown is for letoral support of Individual web members only. Additional temporary bracing to insure stability during construction's the responsibillity of the M1. erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. for general guidance regarding fabrication, quality control, storage, delivery, erection and bracing, consult ANSI/T►Il Dually Criteria, DSB-41 and 4CSI1 Bulling Component MIT@k' Safety Information evoilablo from Trus Plate Institute, 543 D'Onefrie Drive, Madison, WI 53719. Symbols Numbering System Q General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury � 1-13/; 'Center plate on joint unless 4 dimensions indicate otherwise. Dimensions are in inches. Apply 1. Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property securely seat. owner and all other interested parties. J2 J3 J4 2. Cut members to bear tightly against each i . TOP CHORDS other. j C2 C3 J5 3. Place plates on each face of truss at each o °+ joint and embed fully. Avoid knots and wane O at joint locations. �+ U �5 U 4. Unless otherwise noted, locate chord splices IL CL at Y. panel length (t 6" from adjacent joint.) • For 4 x 2 orientation, locate ~ G C7 CL BOTTOM CHORDS 5. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. plates 1 /9' from outside edge A JE J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT is the responsibility of truss fabricator. General FARTHEST TO THE LEFT. practice is to camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT a. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. The first dimension is the width 4 4 9. Lumber shall be of the species and size, and x perpendicular to slots. Second in all respects, equal to or better than the dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins ICBO 3907, 4922 provided at spacing shown on design. LATERAL BRACING SBCCI 9667,9432A 11. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, Indicates location of required WISC/DILHR 960022-W, 970036-N unless otherwise noted. continuous lateral bracing. NER 561 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. TEARING Indicates location of joints at © � 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. engineer. O MiTek 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 © 1993 MiTskm Holdings, Inc. Job ruse Truss Type Qty Ply 00 PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.14 R220i165t KEMP LYNN AGE COMMON 2 1 BC 0.03 Vert(TL) 0.00 21 n/r 120 TCDL 10.0 Rep Stress Incr Job Reference (optional) EMeaver Hamas, Oreville, Co., Matt Wilson o.Zuu a Jui is mun mi ex meusmia, mc. i us am ii w.55:2. 200s raga i -I-" i 12-0-0 i 24-0-0 25.0-0 1-0-0 12-0-0 12-0-0 1-0-0 Scala = 1:42.1 3x4 = 4x4 % 40 Zz 3x4 = 37 36 35 34 33 32 31 30 29 26 27 26 25 24 23 22 3x4 = 5x5 = 24-M LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.14 Vert(LL) 0.00 20 n/r 120 MT20 220/195 (Roof Snow=35.0) Lumber Increase 1.15 BC 0.03 Vert(TL) 0.00 21 n/r 120 TCDL 10.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 20 n/a n/a DCLL 0.0 Code USC/ANSI95 (Matrix) Weight: 121 lb BCDL 10.0 LUMBER BRACING TOP CHORD 2 X 4 DF No.l<r TOP CHORD Sheathed or 6-0-0 oc purlins. DOT CHORD 2 X 4 DF No.1&Btr DOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEDS 2 X 4 DF Std OTHERS 2 X 4 DF Std REACTIONS (Ib/size) 2=234/24-0-0, 20=234/24-0-0, 30=108/24-0-0, 29=23/24-0-0, 37=261/24-0-0, 36=101/24-0-0, 35=157/24-0-0, 34=145/24-0-0, 33=147/24-0-0, 32=150/24-0-0, 31=104/24-0-0, 2$=95/24-0-0,27=151/24-0-0, 26=147/24-0-0, 25=145/24-0-0, 24=157/24-0-0,23=101124-0-0, 22=261/24-0-0,39=99/24-M Max Horz2=63(load case 7) Max Uplifl2=33(load case 5), 20=-40(load case 6), 37=-14(load case 7), 36=15(load case 7), 35=-13(load case 5), 34=14(lead case 5), 33=14(load case 7), 32=-15(load case 5), 31=-10(102d case 7), 28=-9(102d case 8), 27=15(load case 8), 26=14(load case 6), 25=14(load case 8), 24=13(IO2d Case 6), 23=-15(load case 8), 22=-14(load case 8) Max Gr2v2=341(102d case 2), 20=340(102d case 3), 30=110(load case 2), 29=46(load case 4), 37=280(102d Case 2), 36=129(102d case 2), 35=179(102d case 2), 34=168(load case 2), 33=170(lood case 2), 32=175(102d case 2), 31=122(lo2d case 2), 28=114(lo2d case 3), 27=176(102d case 3), 26=170(load case 3),25=168(102d case 3), 24=179(load case 3), 23=129(load case 3), 22=280(IO2d case 3), 39=99(load case 3) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/47, 2-3=-56/39, 3-4=-36/44, 4-5=25/51, 5-6=27/60, 6-7=-27/68, 7-8=-27/76, 8-9=-28/84, 9-10=-17/89, 10-11=58/32, 11-12=-60/31, 12-13=-14/86, 13-14=-28!77, 14-15=-27/63, 15-16=-27/48, 16-17=-27/34, 17-18=-25/22, 18-19=-35/14, 19-20=-54/40, 20-21=0/47 BOT CHORD 2-37=0/48, 36-37=0/48, 35-36=0/48, 34-35=0/48, 33-34=0/48, 32-33=0/48, 31-32=0/48, 30-31/48, 29-30=0/48, 28-29=0/48 27-28=0/48, 26-27=0/48, 25-26/48, 24-25=0/48, 23-24=0/48, 22-23=0/48, 20-22=0/48 WEDS 30-38=-88/1, 10-38=-88/1, 29-39=0/0, 12-39=-99/0, 3-37=233/44, 4-36=-111/25, 5-35=-150/31, 6-34=142/30, 7-33=-144/30 , 8-32=-147/32, 9-31=-106/19,13-28=-98/19,14-27=-148/32,15-26=-144130, 16 25=-142/30, 17-24=-150/31, 18-23=-111/2 .19-22=-233/44,10-12=0/58, 38-39=0/0 NOTES 1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=S.Opsf; BCDL=6.Opsf; Category II; Exp D; enclosed; MWFRS gable end zone; cantilever left right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate trip DOL=1.33. 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry G End Details as applicable, or consult qualified building designer as per ANSI/TPI 1-2002. 3) Unbalanced snow loads have been considered for this design. 4) Overhang has been design for 2.00 times live load + dead load. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Continued on page 2 July 19,2006 0 WARMNG - Verify deelgn Panm.t- ILEA) NOTEa ON TRIS AND DEWDEB SQICTEREFZPZAI PAGE AIU-7473 BEFORE E7119.7777 Sults 1 Greenback Lane Desyn valid for use only with MITsk connectors. This design is based only upon parameters shown, and r for an individual building component. Citrus Heights, CA, 95610 Applicability of design paramenters and Mohr Incorporation of component's responsibility of building assignor - not truss assignor. Bracing shown � � .._ is for lateral support of individual web members only. Additional temporary bracing to insure stability, during construction's the rssponsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the Wilding assigner. For general guidance regarding fabrication, quality control, stores*, delivery, erection and bracing, consult ANSI/T►Il Quality Criteria, DSB-69 and SCSI] Building Component M {Tek• Safety Information available from Truss Plate Institute, 563 D'Onefrie Drive, Madison, WI 53719. Symbols Numbering System ,d General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury *Center plate on joint unless dimensions indicate otherwise. Dimensions are in inches. Apply 1. Provide copies of this truss design to the plates to both sides of truss and building designer, erection supervisor, property owner and all other interested parties. securely seat. J2 J3 J4 2. Cut members to bear tightly against each TOP CHORDS other. V ��� -► ~ C2 C3 J5 3. Place plates on each face of truss at each �+ joint and embed fully. Avoid knots and wane o O -�+' 3 WO at joint locations. = 4. Unless otherwise noted, locate chord splices �, CL " (L at 1A panel length (± 6' from adjacent joint.) O ~ c, V Ca BOOM CHORDS TT 5. Unless otherwise noted, moisture content of • For 4 x 2 orientation, locate lumber shall not exceed 19% at time of fabrication. plates 1 /8" from outside edge Jl Ja J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use With fire retardant or preservative treated lumber. *This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT FARTHEST TO THE LEFT. is the responsibility of truss fabricator. General practice is to camber for dead load deflection. WEBS ARE NUMBERED FROM LEFT TO RIGHT a. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. The first dimension is the width 4 4 Second 9. Lumber shall be of the species and size, and in equal to or better than the x perpendicular to slots. all respects, dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. 6OCA 96-31, 96-67 10. Top chords must be sheathed or purlins provided at spacing shown on design. ICBG 3907, 4922 LATERAL BRACING SdCCI li67, l432A 11. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, Indicates location of required continuous lateral bracing. WISC/DILHR 960022-W, 970036-N NER 561 unless otherwise noted. 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints at innp 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. itil engineer. MiTek` m 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 0 1993 MiTokm Holdings, Inc. • rUSS rUSS ype y 00 KEMP_LYNN AGE COMMON y t R220i1656 Eneeavr N.m•• n,.vrrr. r ts•n sure.... _ Job Reference • 'onal --- •.cuu a vnm ra cwo mu es mausmee, inc. i u. Jul 1■ 13:3527 2001 Rap 2 NOTES C) All plates are 1.5x4 MT20 unless otherwise indicated. 7) Gable requires continuous bottom chord bearing. i) Gable studs spaced at 1-4-0 oc. 9) Bearing at joint(s) 39 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface LOAD CASE(S) Standard 0 WARMNO - ler j fy 4a1an ramnieMn and Rl fD NOTES ON TWO AND 1 CWIED MFTZK REFEREW-C PAGE AM -7473 BEFORE USE. 7777 Greenback Lana Design valla for use any with MRek connectors. This design Is based only upon parameters shown, and b for an individual building component. Suite 109 Applicability of design peremonters and proper inc Citrus Heights, CA, 35610 .l orlloratlan of component's responsibility of building designer -not buss designer. Bracing shown l is for lateral support of individual woe members only. Additional temporary bracing to insure stability during construction r the rospensibillity of the erecter. Additional permanent bracing of the evwell structure is the responsibility of the building designer. For general guidance regarding fabrication, quality control, storage, delivery, eroctien and bracing, consult ANSI/Trn Quality criteria, NS349 and 6CSI1 Building Component M iTek' Sally available vailable from Truss Plate Institute, 583 D'Onefrie Drive, Madison, W1 53719. Symbols Numbering System Q General Safety Notes PLATE LOCATION AND ORIENTATION Failure to Follow Could Cause Property Damage or Personal Injury 3/• 'Center plate on joint unless 4 dimensions indicate otherwise. 1. Provide copies of this truss design to the Dimensions are in inches. apply building designer, erection supervisor, property plates to both sides of truss and owner and all other interested parties. securely seat. J2 J3 J4 2. Cut members to bear tightly against each 1/I TOP CHORDS C3 other. V-► C2 J5 3. Place plates on each face of truss at each c+ joint and embed fully. Avoid knots and wane r W U y 3 O at joint locations. �� = �y " 4. Unless otherwise noted, locate chord splices d at 1A panel length (± 6' from adjacent joint.) O 0 ce C7 ca BOTTOM CHORDS 5. Unless otherwise noted, moisture content of ' For 4 x 2 orientation, locate lumber shall not exceed 19% at time of fabrication. plates 1 /B" from outside edge J 1 JB J7 J6 of truss and vertical web. 6. Unless expressly noted, this design is not applicable for use with fire retardant or preservative treated lumber. 'This symbol indicates the required direction of slots in JOINTS AND CHORDS ARE NUMBERED CLOCKWISE 7. Camber is a non-structural consideration and connector plates. AROUND THE TRUSS STARTING AT THE LOWEST JOINT FARTHEST TO THE LEFT. is the responsibility of truss fabricator. General practice is to Camber for dead load deflection. WEIS ARE NUMIERED FROM LEFT TO RIGHT B. Plate type, size and location dimensions PLATE SIZE shown indicate minimum plating requirements. The first dimension is the width 4 4 Second 9. Lumber shall be of the species and size, and in all respects, equal to or better than the x perpendicular to slots. dimension is the length parallel CONNECTOR PLATE CODE APPROVALS grade specified. to slots. BOCA 96-31, 96-67 10. Top chords must be sheathed or purlins provided at spacing shown on design. ICBO 3907, 4922 LATERAL BRACING SBCCI 9167, 9432A 11. Bottom chords require lateral bracing at 10 ff. spacing, or less, if no ceiling is installed, Indicates location of required continuous lateral bracing. WISC/DILHR 960022-W, 970036-N NER 561 unless otherwise noted. 12. Anchorage and / or load transferring connections to trusses are the responsibility of others unless shown. 13. Do not overload roof or floor trusses with stacks of construction materials. BEARING Indicates location of joints at Ticp 14. Do not cut or alter truss member or plate without prior approval of a professional which bearings (supports) occur. IWI engineer. MiTek`" wSTI= 15. Care should be exercised in handling, erection and installation of trusses. MiTek Engineering Reference Sheet: MII-7473 0 1993 MiTokm Holdings, Inc. STANDARD GABLE END DETAIL QROF • ro I/SAC - 20G .. _ .._ - m1IeR MU• 12116/2005 PAGE 1 OF 2 ----- VERTICAL STUD TYPICAL 2x4 L -BRACE NAILED TO 2x4 VERTICALS W/id NAILS SPACED AT I" O.C. LOADINgpsfl SPACING 2-0-0 TCLL 30.0 Plates Increase 1.15 TCDL 10.0 Lumber Increase 1.15 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code ASCE 7-02 TOP CHORD 2 X 4 DFL/SPF/HF - No.2 BOT CHORD 2 X 4 DFL/SPF/HF - STUD/STD OTHERS 2 X 4 DFL/SPF/HF - STUD/STD also, "I' -,Western DlvHsl1n THING THERS) 1 24" MAX 2TM' O.C. ?X4 LATERAL BRACING kS REQUIRED PER SABLE BELOW i AT a. (MIN.) L END WALL %GID CEILING MATERIAL DETAIL A LATERAL BRACING NAILING SCHEDULE VERT. HEIGHT # OF NAILS AT END UP TO 7'-0"- 5-10-0 11-8-0 -10-0 161 C 10-0-0 - -24 OVER 8'-6" 4 - 16d NOTES 1) VERT. STUDS HAVE BEEN CHECKED FOR 110 MPH WIND EXP. B, HEIGHT 30 FT 2) CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3 FURNISH COPY OF THIS DRAWING TO CONTRACTOR FOR BRACING INSTALLATION. 4) BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 5) DETAIL A (SHOWN ABOVE) APPLIES TO STRUCTURAL GABLE ENDS AND TO GABLE ENDS WITH A MAX VERT. STUD HEIGHT OF W -r. TOP CHORD NOTCHING NOTES 1)THE GABLE MUST BE FULLY SHEATHED W/RIGID MATERIAL ON ONE FACE BEFORE NOTCHING IF STUDS ARE TO BE SPACED AT 24" O.C. ATTACH SCAB (EQUAL OR GREATER TO THE TRUSS T.C.) TO ONE FACE OF THE TOP CHORD WITH 10D NAILS SPACED AT 6" O.C. IF STUDS ARE SPACED AT 24" O.C. AND FACE OF TRUSS IS NOT FULLY SHEATHED. 2) NO LUMBER DEFECTS ALLOWED AT OR ABOUT NOTCHES. 3) LUMBER MUST MEET OR EXCEED VISUAL GRADE 82 LUMBER AFTER NOTCHING. 4) NO NOTCHING IS PERMITTED WITHIN 2X THE OVERHANG LENGTH. Continued on page 2 nuumua•irt1yA.zisnparnmew..suits mcx..nracicLan. R n. tot D.si�n vsir bras sny wnh Mitek unnsct.rs. Thk .syn b wsd sny upsn t.mrrrlsxs shwvn, sn� 4 Isr sn In�wl �ullrin� csm�msnt. Citrus Heights, CA. !SN Im a A(.[.tics�ly sl �esit,n menfers snrr InesrMrsllsn sl esmpnent k rssissrullsgty sl Isulldint, �ssl�ner- nst truss �.si�n.r. Irscln f sh.wn Is I.r Idmsl su'Mrl d nrlvldwl wok rmm�en snly. Asl�itisnsl len>r.rsry Yrscln� t� Msun slslslpty �urin� csnsirvclisn Y IM ns'snslYlHy sl IM sr.etsr. Arslilisnsl Mrm.nent Yncln� sf the sysrsl slrucfurs k the nspnsbt0ty sl the Yulliln� �esi(,ner. Fsr �snenl �uislsncs n�snlln� M iTek' letc.11.n, �uslty esntnl, st.re+/.. s1.Ovay, enelisn sn� Yr�eiry, c.nsult ANSI/��Il Q�allry Ctllerla, DSt•H sn� tC511 �uil�in� C.m'.n.n1 sd"ry Inf.nn.N.n awlls�M hsmTruss �Isl• insliluls, 513 D'Onslris prN., Ms�ls.n, w15a�tr. MAXIMUM VERTICAL STUD HEIGHT SPACING OF VERTICALS WITHOUT BRACE WITH LATERAL BRACE WITH L - BRACE 12 INCH O.C. 5-10-0 11-8-0 -10-0 161 C 10-0-0 - -24 INCH O.C. - 8-4-0 NOTES 1) VERT. STUDS HAVE BEEN CHECKED FOR 110 MPH WIND EXP. B, HEIGHT 30 FT 2) CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3 FURNISH COPY OF THIS DRAWING TO CONTRACTOR FOR BRACING INSTALLATION. 4) BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 5) DETAIL A (SHOWN ABOVE) APPLIES TO STRUCTURAL GABLE ENDS AND TO GABLE ENDS WITH A MAX VERT. STUD HEIGHT OF W -r. TOP CHORD NOTCHING NOTES 1)THE GABLE MUST BE FULLY SHEATHED W/RIGID MATERIAL ON ONE FACE BEFORE NOTCHING IF STUDS ARE TO BE SPACED AT 24" O.C. ATTACH SCAB (EQUAL OR GREATER TO THE TRUSS T.C.) TO ONE FACE OF THE TOP CHORD WITH 10D NAILS SPACED AT 6" O.C. IF STUDS ARE SPACED AT 24" O.C. AND FACE OF TRUSS IS NOT FULLY SHEATHED. 2) NO LUMBER DEFECTS ALLOWED AT OR ABOUT NOTCHES. 3) LUMBER MUST MEET OR EXCEED VISUAL GRADE 82 LUMBER AFTER NOTCHING. 4) NO NOTCHING IS PERMITTED WITHIN 2X THE OVERHANG LENGTH. Continued on page 2 nuumua•irt1yA.zisnparnmew..suits mcx..nracicLan. R n. tot D.si�n vsir bras sny wnh Mitek unnsct.rs. Thk .syn b wsd sny upsn t.mrrrlsxs shwvn, sn� 4 Isr sn In�wl �ullrin� csm�msnt. Citrus Heights, CA. !SN Im a A(.[.tics�ly sl �esit,n menfers snrr InesrMrsllsn sl esmpnent k rssissrullsgty sl Isulldint, �ssl�ner- nst truss �.si�n.r. Irscln f sh.wn Is I.r Idmsl su'Mrl d nrlvldwl wok rmm�en snly. Asl�itisnsl len>r.rsry Yrscln� t� Msun slslslpty �urin� csnsirvclisn Y IM ns'snslYlHy sl IM sr.etsr. Arslilisnsl Mrm.nent Yncln� sf the sysrsl slrucfurs k the nspnsbt0ty sl the Yulliln� �esi(,ner. Fsr �snenl �uislsncs n�snlln� M iTek' letc.11.n, �uslty esntnl, st.re+/.. s1.Ovay, enelisn sn� Yr�eiry, c.nsult ANSI/��Il Q�allry Ctllerla, DSt•H sn� tC511 �uil�in� C.m'.n.n1 sd"ry Inf.nn.N.n awlls�M hsmTruss �Isl• insliluls, 513 D'Onslris prN., Ms�ls.n, w15a�tr. STANDARD GABLE END DETAIL MII/SAC - 20G 12116/20061-51 2/16/2005 PAGE 2 OF 2 4-10d NAILS MIN. ,PLYWOOD SHEATHING TO 2X4 STD. DF -L BLOCK 2-10d (TYP) \ SIMPSON A34 — OR EQUIVALENT 2X4 No. 2 OR BTR GABLE EN 6'-3" MAX TO BEARING WALL 45' STRONGBACK 2X4 No. 2 OR BTR 2X4 BLOCK 2X4 S D OR BTR SPACED @ 5'-0" O.C. SHAL E PROVIDED AT EACH END OF BRAC EXCEPT FOR BRACE EXTENDED INTO E CHORDS & CONNECTED TO CHO S W/ 4-10d NAILS. MAX. NGTH = 7'-0" STANDARD TRUSSES SPACED @ 24" O.C. ALTERNATE BRACING DETAIL FE D V ? At NOTES 1)2X4 NO.2 OR BTR. FOR LEDGER AND STRONGBACK NAILED TOGETHER WITH 10D NAILS @ 6" O.C. 2)2X4 LEDGER NAILED TO EACH STUD WITH 4-10d NAILS. 3)2X4 STRONGBACK TO BE CONNECTED TO EACH VERT. STUD WITH 2-10d TOE NAILS 4)THE 10d NAILS SPECIFIED FOR LEDGER AND STRONGBACK ARE 10d BOX NAILS (0.131" DIA. X 3.0" LGT) THIS ALTERNATE BRACING DETAIL IS APPLICABLE TO STRUCTURAL GABLE END IF THE FOLLOWING CONDITIONS ARE MET: 1. MAXIMUM HEIGHT OF TRUSS = 8'-6", UNLESS OTHERWISE SPECIFIED BY PROJECT ENG. OR QUALIFIED BUILDING DESIGNER. 2. MAXIMUM PANEL LENGTH ON TOP AND BOT. CHORDS = T-0" 3. THE HORIZONTAL TIE MEMBER AT THE VENT OPENING SHALL BE BRACED @ 4'-0" O.C. MAX. 4. PLEASE CONTACT TRUSS ENGINEER IF THERE ARE ANY QUESTIONS. O WAXNWa - IerVy d8signOxfornoters end REA) EG7Ee OAF IMS AND INCLUBXD JCrrM RIPIREI=X PAGE AW -7473 )E"RI USI. 7777 Greenback Lane on! � Design void far use Suite 106 any with MRek connectors. This design h r.r.d any upon pmrtretors shown enol r for individual ruding component. Clrus Heights. CA. 9561 Applicability d design oramentors and proper tncerperdlon of component b respensbllly of rUnding dodgner-rad Inns designer. "racing shown r for "doral sup�port of ividuai Wer members any. Addlllenal temporary bracing t=ry sloriGly during Construction r the respenshl@ly of tho ereeter. Additional permanent bracing of the overall structure r the resperalrlPly of the building designer. For genera" guidance regarding fabrication, quality contn4 storago, delvery, erection and tracing, consult ANSI/TPI7 Qua9y Criteria, NS149 and BCSit building Component M "Tek4 Soley Information available from Tens Plate Institute. 523 D'OneHe Drive, Medisen, Wl 53719. California Department of Forestry and Fire Protection Butte County Fire Department C Fire Safe Requirements Permit# O Under authority of Public Resources Code Section 4290 and 4291, Butte County Improvement standards , and the California Building Code, the following checked items are required by CDFButte County Fire Department and L` made part' of this permit. These requirements are minimums and may be superseded by Butte County local 1' regulations, which exceed these standards. Butte County Building Inspectors will make the compliance inspections. 1272.00 Maintenance of Defensible Space Measures [X] To ensure continued maintenance of properties in conformance with these standards and measures and to assure continued availability, access, and utilization of the defensible space provided for these standards during a wildfire, provisions for annual maintenance shall be included in the development plans and/or shall be provided as a condition of the permit, parcel or map approval. Public Resources Code 4291 T 1 information will be provided. 1273.10 Driveways [X] (a) All new driveway construction or an extension of an existing driveway shall comply with Public R Resources Code 4290 roadway requirements. 15 [X] (b) All driveways shall provide a minimum 10 foot traffic lane and unobstructed vertical clearance of feet along its entire length. [X] (c) Driveways exceeding 150 feet in length, but less than 800 feet in length, shall provide a turnout near the than midpoint of the driveway. Where the driveway exceeds 800 feet, turnouts shall be provided no more 400 feet apart. [X] (d) A turnaround shall be provided to all building sites on driveways over 300 feet in length, and shall be within 50 feet of the building. 1273.02 Roadway Surface [X] The surface shall provide unobstructed access to conventional drive vehicles, including sedans and fire engines. Surfaces should be established in conformance with local ordinances, and be capable of supporting a 40,000 pound load. 4" of class 2 aggregate base shall be required for all driveways, turnouts, and turnarounds. 1273.03 Roadway Grades [X] The grade for all driveways shall not exceed 15 percent. Grades above 15% shall have 4" of class 2 aggregate base and 2" of asphalt concrete. No driveways allowed in excess of 20%. 1273.04 Roadway Radius [X] (a) No roadway shall have a horizontal inside radius of curvature of less than 50 feet and additional surface width of 4 feet shall be added to curves of 50-100 feet radius; 2 feet to those from 100-200 feet. [X] (b) The length of vertical curves in roadways, exclusive of gutters, ditches, and drainage structures designed to hold or divert water, shall be not less than 100 feet. 1273.05 Roadway Turnarounds [X] Turnarounds are required on driveways and dead-end roads as specified in this article. The minimum turning radius for a turnaround shall be 40 feet from the center line of the road. If a hammerhead -T is used, the top of the "T" shall be a minimum of 60 feet in length. 1273.06 Roadway Turnouts [X] Turnouts shall be a minimum of 10 feet wide and 30 feet long with a minimum 25 foot taper on each end. . 9 t.+'k g;.` Revised 07/25/06 �.10.a6ri4,e 1273.07 Roadway Structures [X] (a) All driveway, road, street, and private lane roadway structures (Bridges, culverts, and other appurtenant structures which supplement the roadway bed,or shoulders) shall be constructed to cant' at least the maximum load and provide the minimum vertical clearance as required by Vehicle Code Sections 35550, 35750 and 35250. [X] (b) Appropriate signing, including but not limited to weight or vertical clearance limitations, one-way road or single lane conditions, shall reflect the capability of each bridge. [X] (c) A bridge with only one traffic lane may be authorized by the local jurisdiction; however, it shall provide for unobstructed visibility from one end to the other and turnouts at both ends. All bridges must be certified by a registered Civil Engineer. 1273.11 Gate Entrance [X] (a) Gate entrances shall be at least two feet wider on both ends then the width of the traffic lane(s) serving that gate. [X] (b) All gates providing access from a road to a driveway shall be located at least 30 feet from the roadway and shall open to allow a vehicle to stop without obstructing traffic on that road. [X] (c) Where a one-way road with a single traffic lane provides access to a gated entrance; a 40 foot turning radius shall be used. 1274.0E Addresses for Buildings [X] All buildings shall be issued an address by the local jurisdiction which conforms to that jurisdiction's overall address system. Accessory buildings will not be required to have a separate address; however, each dwelling unit within a building shall be separately identified. 1274.09 Size of Letters, Numbers and Symbols for Addresses [X] Size of letters, numbers and symbols for addresses shall be a minimum 3" letter height, 3/8" stroke, reflectorized, contrasting with the background color of the sign. 1274.10 Installation, Location and Visibility of Addresses [X] (a) All buildings shall have a permanently posted address, which shall be placed at each driveway entrance and visible from both directions of travel along the road. In all cases, the address shall be posted at the beginning of construction and shall be maintained thereafter, and the address shall be visible and legible from the road on which the address is located. [X] (b) Address signs along one-way roads shall be visible from both the intended direction of travel and the opposite direction. [X) (c) Where multiple addresses are required at a single driveway, they shall be mounted on a single post. [X] (d) Where a roadway provides access solely to a single commercial or industrial business, the address sign shall be placed at the nearest road intersection providing access to that site. 1276.01 Setback for Structure Defensible Space [ ] (a) All parcels 1 acre and larger shall provide a minimum 30 foot setback for buildings and accessory buildings from all property lines and/or the center of the road. [ ) Your parcel is larger then 1 acre but your required minimum setback for buildings and accessory buildings is less then 30 feet from all property lines and/or the center of the road. You are required to meet the same practical effects requirements listed on page three. (b) For parcels less than 1 acre, the local jurisdiction shall provide for the same practical effect. See page three for same practical effect requirements. [ ] Your parcel is less then 1 acre and your buildings and accessory buildings meet the 30 foot setback requirements from all property lines and/or the center of the road. Revised 0725/06 2 If the Building Setback is less then 30 Feet from all property lines and/or the center of the road, the following shall be required; • ;Class A roof • Fully enclosed eaves on entire structure (December 5, 2005, per 2001 California Building Code 704A.2.3, fully enclosed eaves are required on all structures in any fire hazard severity zone within State Responsibility Areas, regardless of setback distance from the property line or center of roadway) • Fire rated metal doors on side toward property line with insufficient setback • ,Siding on entire structure from the following list: !(a) Stucco -3 coat (b) Non combustible Hardi-Board, Plank or similar siding (c) Masonry (d) Metal (e) Other Butte County Fire Department approved materials 1276.02 Disposal of Flammable Vegetation and Fuels [X] Disposal, including chipping, burning or removal to a landfill site approved by the local jurisdiction, of flammable vegetation and fuels caused by site development and construction, road and driveway construction, and fuel modification shall be completed prior to completion of road construction or final inspection of a building permit. Other Requirements Butte County Improvement Standards Installation of Residential Fire Sprinklers [X] If your property was part of a parcel split atter January 1, 1991, you are required to install residential fire sprinklers. It is your responsibility to inspect the official parcel map to confirm if sprinklers are required. 2001 California Building Code, December 5, 2004 704A.1 Roofing. 704A.1.1 General [X] Roofs shall comply with the requirements of Chapter 7A and Chapter 15. Roofs shall have a roofing assembly installed in accordance with its listing and the manufacturer's installation instructions. 704A.1.2 Roof coverings [X] Where the roof profile allows a space between the roof and roof decking, the spaces shall be constructed to prevent the intrusion of flames and embers, be fire stopped with approved materials or have one layer of No. 72 ASTM cap sheet installed over the combustible decking. 704A.1.3 Roof valleys [X] When provided, valley flashings shall be not less than 0.016 -inch (0.41mm) (No. 2E galvanized sheet gage) corrosion -resistant metal installed over a minimum 36 inches (914 mm) wide underlayment consisting of one layer of No. 72 ASTM cap sheet running the full length of the valley. 704A.1.4 Roof gutters [X] Noncombustible screens on gutters. Roof gutter shall be provided with the means to prevent the accumulation of leaves and debris in the gutter. 704A.2 Attic Ventilation. 704A.2.1 General [X] When required by Chapter 15, roof and attic vents shall resist the intrusion of flame and embers into the attic area of the structure, or shall be protected by corrosion resistant, noncombustible wire mesh with '/. inch'(6mm) openings or its equivalent. Revised 0725/06 3 704A.2.2 Eave or cornice vents. [X] Vents shall not be installed in eaves and cornices. EXCEPTION: Eave and cornice vents may be used provided they resist the intrusion of flame and burning embers into the attic area of the structure. 704A.2.3 Eave Protection. [X] Fully enclosed noncombustible eaves on entire structure. Eaves and soffits shall meet the requirements of SFM 12-7A-3 or shall be protected by ignition -resistant materials or non combustible construction on the exposed underside. AUG 0 2'2006 Date Revised 07/25/06 All of the Butte County Fire Department requirements are posted on our website at http://b utteriire.o r=/Fi repreven tiontprotPl2 n/prOtPl2n.h tml 4 Darren Read Fire Protection Planning t CDFButte County Fire AN new buildings in SRA are required to have: Fully enclosed noncombustible eaves on entire stricture Gutter screens to prevent accumulation of leaves/debris"', Corrosion resistant, noncombustible, V4"maximum opening roof and attic vents This project is required to meet the same practical effect guideline outlined in the attached PRC4 e`d 4 � .,�ii; Requirements. REMEWEDBY Fir! Protectim Planning Officer CDF, Butte County Fire This project is approved with compliance conditions on attached sheet Si a ure Date ass 14' �,� 1'� tin. `--� ��'\ •�� 1��--'�� PLANNING DIVISION - BUILDIW3 RAN APPROVAL �. r-r.\� Use:'14Date: V 210to Parking._ Landscaping: Other. Signature: �(' te" C (0 f)(;� Q cj:� r �,� 1'� tin. `--� ��'\ •�� 1��--'�� PLANNING DIVISION - BUILDIW3 RAN APPROVAL �. r-r.\� Use:'14Date: V 210to Parking._ Landscaping: Other. Signature: �(' te" C (0 f)(;� I tit'�CKNIAITIIM /NIM IN. 1.111 2-. 4- STUDS e IWO-C t-�,,10 "ANC440f- 501-T d'O.C. 2VC4 F. -G 51 LL, 411cowc. 5LA5 7 GRAPP- CL; :t 4 < adv U 0 0;/ A 4" GRAVE -t- FILL UNQr_�,TUSj3F_ E K? 4 Xetw.L coNil 1j. Tor + 5cri rol-1 —'5" ti IN, CLEAX-k- 17.11 F_0_(DT11�G- 1?1�_TAIL 150 %frL COMP 15 31 MLT 12• Iy3zcxs,o, RmcF 6wearRil,46 MAN. -rtLut6eS - Z4"O.C,, 0.) ZX4 Tor I,LATes -, E-4 &TU P 6 Or -- P () RA'TF-t v1 P'71;, I•( -- I sw1we. r-IGs 5412E 4 af-AIL 10 o 0 WVVM 4(66;=W1_ FII -I.- &4 Mr. SILL rL. v. 6C41,LP--Y,4 It= =o0 T-8" MH. e (2) 2"X fCF FLAZ H KKR 2"A" MIN. 5aV OLK6 IT017 llf.MM Jow (CMW Pa to 9fMNM M MA[ M7 I-EAHZ 3/ 8" MIN. AMP f0 at fta. WL WIH N CCM04 CK 4V. WX W-35 J. e OL. Waz wail. my it O.C. N FEW PaME 511125 Af MUM COLMEM W15 & WAIM MIN. 1/ 2" OAP. AM M5 WM I" MN. eWfL7htWAf ma aml!ll POW5 1HIGOOx MN. CN'PLItY 11 (SI W2& W5& CK EGLIAL) iI:, 2"X 5aE n.A9 % v I rowoco rtc. 5ff I= 0 L T_ 2"X ROLL, IQL %U11t 901K a 61, OL. "I", all f IN. rh r" L to to ---------------------------------------------- --------------------------------J-1 ---------- ----------------------------- - - -- ------•--------------------------- ALTERNATE ---------------------------------ALTERNATE BRACED WALL PANEL NOTES: 1. Floor framing consists of dimensional lumber. 2. Simpson SSTB anchor bolt with coupling at double mudsill and thrcadctd anchor rod for connection to coupling and holdown. 3. #4 Rebar, continuous at top and bottom or sternwall. Additional relbar may be rquired by manufacture of holdown. 4. In the first story of a two-story building, each braced wall panel shall bye in accordance with the details shown. Except that the plywood sheathing shall be provided on both faces and.tic-down device uplift capacity shall not be less than 3000 pounds. Nailing to be staggered for sheathing, applied to broth faces. 5. Alternate Braced Wall Panel's cannot be used on the second floor of two - story buildings (1!.B.C. 2326.11.4). For Sinele Stoa Buildings with kaised Floor (With notal nimfirications fur two story buildiings) PqAf*, LAF1 A I P I N 6 CIA f'OeAq, FLY - F94:)IM+ MCOW 61 M 77 7 C70L15Ls -iof, Pum-- , 2.-4 KING STUD (2) 2,4 TIZ-1 M HEV e 21( EAVE 5LI-C MA?4.Trj65 2W'o.c H I CLI P,5 (W!:. 5 Tr s; T-1-11 51P)KG OR. Y5 o.!5.E5.514EArz, , PETAI I scx--F_ - 1 1'-O" FIGHT51PEEL PATION i I -/4 �=, -P�oN T � g Io �� I - • I V I!AV eS KI PGE - "CALF_ _ALF_ 0 2o l BUTTE COUNTY' T' *.' BUILDING DIVISION i,.-. r- ir zo . zb'_ off 01 2g4- PF op. (Tff. Zy. 6 5AfZGF- 211.4 12- o. H. GA Fe, AG ff- 5 LA5 i i (I 4" CC -04,,' 51A5 W1 &Kew >x 10 WWM IZI 0 M II 40 �.: ML IN LL. 0 k) CQ C1►� �� j 1`10 c_'W-Ov 0,C, l_AJP Fu END, eel 4 NAILTO 41sr # SC W. -DK OLAMH z5 w 4 S' 6E --T', GIAK., Pco(t_ o6�jkAL0?1, MIN. 510INC,-, x -f L4 -.C) V//,5.i GbW, - �- V W 0 1 C, , I rj,> (*I-,>. (zooms(zooms(zooms'r FLAN -4Z- 0" OOIZACLD 0 PAN I! L - sac MTAIL -- LeFT F LoOK, FICDUNP.4�T.% IoN �'Lgw 6CL,_V, j�oq L111 UT. H.9?6 10 M 4xit u,o,14 7, U, 0, N c•wm -"a, Fr 1T -S M DT STD o sm 6TU P 5 To 5 9 '61"ru P C--r&kve M OMK I REVISIONS I BY I CONSTRUCTION NOTES: CGENIERAL. CONDITIONS: I. The Contractor shall verify all dimensions and details prior to construction and notify the Engineer of any discrepancies. 2. All construction and methods shall be in strict conformance with the applicable provisions of the California Building code, 2001 Edition, and the latest edition of the UMC, UPC, NEC, and applicable municipal, state, and Federal regulations 3. All work is subject to building department field Inspector's approval. 4. The contractor shall provide all measures necessary to protect the structure, workmen, and all other persons during construction. -FOUNDATION: 1. The Contractor shall be responsible for the location of all underground facilities or other buried objects which may be encountered but which are not shown on these plans. Locations and depths of any existing utilities that may or may not be shown on these plans they are approximate and may not be complete. 2. Foundation design is based upon an assumed soil bearing capacity of as detertmined by local Building Department or soils report. 3. All excavations shall be inspected and approved by the Building Official before concrete is poured . Footings shall be at least 12 inches wide, and extend at least 12 inches into the prepared pad, or as directed by the Engineer, whichever is lowest. Engineered fill may be used as existing grade provided tests are presented to the Engineer of a 90% relative compaction. 4. The bottom of all footings shall be level. 5. The Contractor shall be responsible for determining the exact location of all ainchor bolts, holdown anchors or straps, and embedments, prior to placement of concrete. 6. Anchor bolts to be 1/2" diameter X 10" long with 7" embedment into concrete spaced at 6'-O" oz. maximum unless otherwise noted on plans, shearwall schedule, or details. Bolts shall be located within 12" of each end of 2x sill plate with a minimum of two anchor bolts per sill plate. 7. Any unusual soil conditions such as organic soils, clay pockets or uncertified fills shall be brought to the attention of the engineer prior to construction. 8. Clean footing excavations of debris and loose soil prior to placing concrete. 9. Slope the ground surface away from footings to direct water awa from the foundation and prevent water ponding next to the footings. Provide 1/2" per foot slope away for 6'. 10. Provide an 18" x 24" under floor access. If. Wali stems may be 8" cmu with all cells grouted with *4 a 24" o.c. horiz. and vert. or 6" wide concrete. 12. Provide 6" x 14" screened under floor vents per code C0NICRETE: I. Ail concrete shall have a cement factor of 5 sacks per cubic yard, a maximum slump of 4" and a minimum fc=2,500 psi after 28 days curing unless otherwise noted. 2. Vibrate concrete around all bolts, rebars and surfaces. 3. Construction joints shall be clean and wet prior to pouring concrete. 4. Aggregate size shall be a maximum of 1-1/2' in foundations and 3/4" at all other locations Curing compound shall be sprayed on all exposed surfaced Immediately after finial troweling. 5. All cement shall conform to ASTM Standard C-150. All aggregates shall conform to ASTM Standard C-33. 6. Unless shown otherwise, the minimum concrete cover for reinforcing shall be 2" except when concrete is to be placed directly against earth where it shall be 3". WOOD: .. i 1. All wood bearing on concrete shall be pressure treated Hem -Fir 2. Holes for bolts shall be bored with a bit 1/32" to 1/16" larger than nominal bolt diameter. 3. All bolt heads and nuts against wood shall bear against 2" x 2" x 3/16" steel washers, unless special washers are called for on plans or details. STEEL: I. Reinforcing steel shall conform to the provisions of ASTM A-615 Grade 40 for 04 i smaller, ASTM A-615 Grade 60 for *5 bars and larger. All rebar to be deformed and all splices shall not be less than 50 bar diameters of the larger bar. Horizontal laps in adjacent bars shall be staggered 5'-0" minimum. 2. Bolts and nuts shall conform to the provisions of ASTM A307, Grade A. TABLE I 11 PER BASE OR POURED iN-PLACE CONCRETE FOOTING DIMENSIONS MAXIMUM PIER LOADS (LBS) SEE NOTE 1 ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF 1500 2000 2500 3000 3500 4000 4500 5000 FOOTING SIZE 16" x 14" 16" x 18" 16" x 23" 16" x 27" 24" x 21" 24" x 24" 24" x 27" 24" x 30" MAXIMUM PIER LOADS (LBS) SEE NOTE I Cq*qs*Ce = 0.0226 KSF (0000 7000 8000 9000 10)000 11)000 12)000 13,000 FOOTING SIZE 30" x 29" 30" x 34" 32" x 36" 36" x 36" 36" x 40" 36" x 44" 36" x 48" 36" x 52" NOTES: 1. SEE FLOOR PLAN FOR MiNIMUM PIER CAPACITY UNDER RIDGE BEAM SUPPORT POSTS. 2. LARGE SUPPORT POST LOADS MAY REQUIRE DOUBLE PAIR APPLICATION (SEE DETAIL A ON MFG. PLANS) CHECK MAXIMUM PiER CAPACITY WITH METAL PIER MANUFACTURER. TABLE II FOOTING SiZE FOR INTERIOR PiERS ALLOWABLE SOIL BEARING PRESSURE = 1000 PSF ON -CENTER PIER SPACING PIER LOAD FOOTING SIZE 6' 21320 24" x 13" 8' 28480 24" x 17" 10' 3553 24" x 22" 12' 4264 24" x 24" TABLE III ANCHOR BOLT SPACING AT PERIMETER STEMW►LL LOCATION OF ANCHOR MAXIMUM SPACING WALL LINE BOL'r SiZE OF BOLTS SHORT -WALL HEIGHT OF BLDG- (Hbldg) = E = P * VW 0.245 W (PER UBC EQ. 30-1) AT EACH ENO I/2" OIAM. 34" ON CENTER LONG WALL AT EACH SiDE 1/2" DIAM. 72" ON CENTER NOTES: 1. A MINIMUM OF 2 BOLTS PER SILL PLATE ARE REQUIRED. 2. BOLTS SHALL BE INSTALLED A MAXIMUM OF 12 FROM END OF SILL PLATE 3. 2" X 2" X 3/16" STEEL WASHERS ARE REQUIRED AT EACH BOLT. 4. EACH BOLT SHALL HAVE A MINIMUM EMBEDMENT OF 7". 5. THE ANCHOR BOLT CALCULATIONS ARE BASED ON A PREMANUFACTURED HOME WITH A MAXIMUM LENGTH OF 70 FEET AND A MAXIMUM WIDTH OF 40' FEET AND A MAXIMUM WEIGHT OF 75,000 POUNDS WITH A MAXIMUM PLATE HEIGHT OF 8' AND A MAXIMUM ROOF PITCH OF 4 : 12. STRUCTURAL CALCULATIONS: FOI,NdDATiON ANCHORAGE FOR SINGLE FAMILY RESIDENCE BASED ON TM 2001 CAL.iFORIS" BUILDING CODE. GRAVITY L.OADSs ROOFS COMPOSITION SHINGLES 3.0 PSF 1/2" OSB OR PLYWOOD 1.5 PSF FRAMING 3.0 PSF R-30 INSULATION (OPTIONAL) 2.0 PSF 5/8" GYPSUM WALLBOARD 3.2 PSF MISCELLANEOUS 13 PSF DEAD LOAD 14.0 PSF LATERAL LOADS SEISMIC 2.5 *036 *W = 0J64 W FOR LIGHT FRAMED SHEARWALLS 5.5 WHERE R =55 75.0 K SOIL PROFILE = Sd FOR STIFF SOIL PROFILE Ca = 036 PER UBC TABLE 16-Q P = 1.50 HEIGHT OF BLDG- (Hbldg) = E = P * VW 0.245 W (PER UBC EQ. 30-1) NET FORCE = 0.245 W/1.4 = OJ75 W VMS EXPOSURE= C METHOD 2 WIND SPEED = 80 MPH Cq 13 qs 16.4 PSF Ce 0-15' = 1.06 Cq*qs*Ce = 0.0226 KSF SLOPE Wbtd 2x• ST =EL MAiN RAIL )D WEDGE SHIM B"xlb" MASONRY BLOCK )ISTURBED SOIL INTERIOR PIER DETAIL 12" N.T.S. MOBILE HOME BY OTHERS 2x4 TOP PLATE 16d NAiLS A 12" O.C. 3/8" CDX OR EQUAL W/ 8d 0 6"/1211' OR 5/16" HARDIEPANEL SIDING WITH 8d HOT DIPPED GALV. NAILS a 6"/12" INSTALL PER MFG. RECOMMENDATIONS 2x4 PRESSURE TREATED SILL 8d GALV. a 6" O.C. EDGES 12" FiELD _z UNDISTURBED SOIL _X N_ I/2"xi01 A.B. WITH SPACING PER TA6LE III ON THiS SHEET WITH 2" X 2" X 3/16" THICK STEEL WASHER 1k4 REBAR C0I^4TUN40:JS _ __ TOP t BTM. FOOTING DETAIL LATERAL FORCE PERPENDICULAR btu TO RIDGE WiND FORCE: (Vwind) = Pwlnd * (Lbidg/2)*(Hridge - Hbldg/2) Vwind = 8.44 K SEISMIC FORCE (Vseismic) = (WT/2) * k Vseismic = rob K (WIND GOVERNS) ANCHOR BOLT SPACING (ABspacing) = OfoOOK/BOLT * Wbidg/V ABspacing = 34J IN LATERAL FORCE PAPAL L Ft TO RIDGE WIND FORCE (Vwind) = Pwind * (Wbldg/2)*(Hridge - Hbldg/2) Vwind = 4.8 K SEISMIC FORCE (Vseismic) = (WT/2) * k \"seismic = 6.6 K (SEISMIC GOVERNS) ANCHOR BOLT SPACING (ABspacing) = 0.60OK/BOLT * Lbldg/V ABspacing =16.4 IN USE: • - • •- c• 0 • ■ • f • �� :� IIIIIIIII1111ka 101 q 4,14, Ica■ i ID ■*^A�41adr��u+•zi'd3�r� +�' 3'",.� '0� ?�44;°4`vx >���, ",X'�7an U �,��.* ry �Fn.:K.R+i �g+�.nga. ..4 �c r+w� ...e..k.c wgr�uv* ii ru..i � S ,-/_ �s, .. r+� .�n�t^.s � a��v Sa .#� .5' �>�_ ,.i ��i�°'Sa'r.�..ss-t« t a � .. `::.. _. �.".� N.T.S. zd f� N in 1 1 fAyJ STEEL MAIN RAIL WOOD WEDGE SHIM 6"x8"x16" MASONRY BLOCK 2x12 PRESSURE TREATED MIN. OF 24" LONG OR USE "ABESCO" PADS INSTALLED PER MANUFACTURER'S SPECIFICATIONS UNDISTURBED SOIL 2"x611x8" PRESSURE TREATED BLOCK WiTH SHIMS 6"x8"x16" MASONRY BLOCK UNDISTURBED SOIL a 1111 U i-- - :�nt - "L 2 *4 REBAR EACH WAY TABLE I INTERIOR PIER DETAIL 12" N.T.S. MANUFACTURED HOME BY OTHERS 3/8" CDX OR EQUAL W/ 8d 0 6"/12" OR 5/16" HARDIEPANEL SIDING WITH 8d HOT DiPPED GALV. NAiLS 0 611/12" INSTALL PER MFG. RECOMMENDATIONS PLYWOOD SPLICE 3/8" CDX OR EQUAL W/ 8d A 6"/12" 4x6 RiM WITH VENT PER CODE 2x4 PRESSURE TREATED SILL UNDISTURBED SOIL 1/2"xlO" A.B. WITH SPACING PER TABLE III ON THIS SHEET WITH 2" X 2" X 3/16" THICK STEEL WASHER $4 REBAR CONTINUOUS TOP t BTM. FOOTING DETAIL N.T.S. PRINTF SEP 0 8 2Q03 FOUNDATION DESIGN CRITERIA THE FOUNDATION AND ANCHOR BOLTS SHALL BE DESIGNED 1N ACCORDANCE WITH THE '98 CBC AND DESIGNED FOR THE FOLLOWING MiNIMUM CRITERIA: WIND SPEED: 80 MPH WiND EXPOSURE: C ©3 - ZS SEISMIC ZONE: 3 «; ; .•• M O. 00 OE Lo U .6 X C U_ a2 a oac c Z Z o' 6M gU"`ai � 0 45 N � U p -Q o A cv U Q_ 3 L ■ O L V O W V V 0 se > m LY La Design: '.JMR Checked: JMR Date: SEPTEMBER, 2003 Job No. 8405 Sheet: 1 of I Sheets WEIGHT OF BUILDING (WT) = 75.0 K LENGTH OF BLDG. (Lbidg) = 70 FT WiDTH OF BLDG_ (Wbidg) = 40 FT HEIGHT OF BLDG- (Hbldg) = 8 FT HEIGHT OF RIDGE (Hridge) = 14.7 FT SLOPE Wbtd 2x• ST =EL MAiN RAIL )D WEDGE SHIM B"xlb" MASONRY BLOCK )ISTURBED SOIL INTERIOR PIER DETAIL 12" N.T.S. MOBILE HOME BY OTHERS 2x4 TOP PLATE 16d NAiLS A 12" O.C. 3/8" CDX OR EQUAL W/ 8d 0 6"/1211' OR 5/16" HARDIEPANEL SIDING WITH 8d HOT DIPPED GALV. NAILS a 6"/12" INSTALL PER MFG. RECOMMENDATIONS 2x4 PRESSURE TREATED SILL 8d GALV. a 6" O.C. EDGES 12" FiELD _z UNDISTURBED SOIL _X N_ I/2"xi01 A.B. WITH SPACING PER TA6LE III ON THiS SHEET WITH 2" X 2" X 3/16" THICK STEEL WASHER 1k4 REBAR C0I^4TUN40:JS _ __ TOP t BTM. FOOTING DETAIL LATERAL FORCE PERPENDICULAR btu TO RIDGE WiND FORCE: (Vwind) = Pwlnd * (Lbidg/2)*(Hridge - Hbldg/2) Vwind = 8.44 K SEISMIC FORCE (Vseismic) = (WT/2) * k Vseismic = rob K (WIND GOVERNS) ANCHOR BOLT SPACING (ABspacing) = OfoOOK/BOLT * Wbidg/V ABspacing = 34J IN LATERAL FORCE PAPAL L Ft TO RIDGE WIND FORCE (Vwind) = Pwind * (Wbldg/2)*(Hridge - Hbldg/2) Vwind = 4.8 K SEISMIC FORCE (Vseismic) = (WT/2) * k \"seismic = 6.6 K (SEISMIC GOVERNS) ANCHOR BOLT SPACING (ABspacing) = 0.60OK/BOLT * Lbldg/V ABspacing =16.4 IN USE: • - • •- c• 0 • ■ • f • �� :� IIIIIIIII1111ka 101 q 4,14, Ica■ i ID ■*^A�41adr��u+•zi'd3�r� +�' 3'",.� '0� ?�44;°4`vx >���, ",X'�7an U �,��.* ry �Fn.:K.R+i �g+�.nga. ..4 �c r+w� ...e..k.c wgr�uv* ii ru..i � S ,-/_ �s, .. r+� .�n�t^.s � a��v Sa .#� .5' �>�_ ,.i ��i�°'Sa'r.�..ss-t« t a � .. `::.. _. �.".� N.T.S. zd f� N in 1 1 fAyJ STEEL MAIN RAIL WOOD WEDGE SHIM 6"x8"x16" MASONRY BLOCK 2x12 PRESSURE TREATED MIN. OF 24" LONG OR USE "ABESCO" PADS INSTALLED PER MANUFACTURER'S SPECIFICATIONS UNDISTURBED SOIL 2"x611x8" PRESSURE TREATED BLOCK WiTH SHIMS 6"x8"x16" MASONRY BLOCK UNDISTURBED SOIL a 1111 U i-- - :�nt - "L 2 *4 REBAR EACH WAY TABLE I INTERIOR PIER DETAIL 12" N.T.S. MANUFACTURED HOME BY OTHERS 3/8" CDX OR EQUAL W/ 8d 0 6"/12" OR 5/16" HARDIEPANEL SIDING WITH 8d HOT DiPPED GALV. NAiLS 0 611/12" INSTALL PER MFG. RECOMMENDATIONS PLYWOOD SPLICE 3/8" CDX OR EQUAL W/ 8d A 6"/12" 4x6 RiM WITH VENT PER CODE 2x4 PRESSURE TREATED SILL UNDISTURBED SOIL 1/2"xlO" A.B. WITH SPACING PER TABLE III ON THIS SHEET WITH 2" X 2" X 3/16" THICK STEEL WASHER $4 REBAR CONTINUOUS TOP t BTM. FOOTING DETAIL N.T.S. PRINTF SEP 0 8 2Q03 FOUNDATION DESIGN CRITERIA THE FOUNDATION AND ANCHOR BOLTS SHALL BE DESIGNED 1N ACCORDANCE WITH THE '98 CBC AND DESIGNED FOR THE FOLLOWING MiNIMUM CRITERIA: WIND SPEED: 80 MPH WiND EXPOSURE: C ©3 - ZS SEISMIC ZONE: 3 «; ; .•• M O. 00 OE Lo U .6 X C U_ a2 a oac c Z Z o' 6M gU"`ai � 0 45 N � U p -Q o A cv U Q_ 3 L ■ O L V O W V V 0 se > m LY La Design: '.JMR Checked: JMR Date: SEPTEMBER, 2003 Job No. 8405 Sheet: 1 of I Sheets