PERMIT NO. 1225-83B
aLL
PERMIT EXPIRES 3 I �l v
OWNER DOYLE RIDLING
CONTR. Acro LUme, Magalia
ASSESSOR PARCEL 65-38-34
LOCATION 14737 Wood Drive, Magalia
Temp. Power Pole
Called PG&E
0
Temp. Elec. Service
Called PG&E
Temp. Gas Servi ci
7 Called PG&E
JOB FINALED (D
Signature
J OK
0 = Not OK
= Not Applicable MOBILEHOMES MISCELLANEOUS
= Not Ready �� 1
Date
MOBILEHOME UTILITIES (Plans) OK except It's
Date
DEC2(a2YPK CARPORTS, ETC. (Plans) OK except N's
1. Zoning Requirements -Setbacks -Easements
1, Z ing Requirements -Setbacks -Easements
2. Soils; Special MH Support -Sketch
2. Footings; Si -Depth-Spacing-Connectors
3. Sewer; Location -Test -Fall -C/0 -Concrete
_
3. Decks ,rders and/or Joists -Decking -Bracing -Stairs -Rails
4. Water; Location -Test -Easement Needed (Sketch)
5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete
4, od Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rig.-Bracing
5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures
6. Gas; Location -Test -Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG
7. Utility Clearance
6. Carports; Windows -Doors -
7. Elec.
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date
Date Card -BI Date
MOBILEHOME INSTALLATION (Plans) OK except N's
1. Zoning Requirements -Setbacks -Easements
Card -BI
Date
_
D to and -BI Date _
OLS (Plans K exc II's
1. Setbacks -Easements
2. Footings; Size -Spacing -Marriage Line
2. Soils; Compaction -Structure Stability -
3. Gas; MH Test -Demand -Valve -Connector
4. Electricity; MH Test -Crossovers -Breakers -Clearances
3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining
4. Elec.; Receptacles and Lighting; Distances-GFI
5. Drain; MH Test -Fall -Flex Connector
5. Elec.; Pool Lighting; 15 volts-GFI
6. Water; MH Test -Regulator -Connector
7. Water and Sewer Connected -C/0 to Grade -HD Approval
6. Elec.; Enclosures; Conduit Entries -Terminals -Listed
7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater
8. Gas and Electricity Tagged
8. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg.
Boxes -Enclosures -Panel boards -Ins. to Main in Conduit
9. Exits; Insp.-Sketch
10. Cert. of Occupancy
9. Health Department Approval
10. Plumb; Cir. Test -Water Supply Test
Card B -I
Card B -I
Date Card -B1 Date
Date Card -BI •Date
Card -BI
Card -BI
Date Card -BI Date
Date Card -BI Date
J = OK
0 = Not OK �-
= Not Applicable
iF = Not Ready RESIDENTIAL (Single and Duplex)
Date
UNDERFLOOR Plans OK except#'s
Date
FRAMING (Continued)
1.
Zoning requirements -Setbacks -Easements
48.
Property Line Firewall & Openings
2.
Ftg., Main; Soils-Steel-Elec. Grnd.- / /'' Ftg. Depth
49.
Ext. Doors -One 3' -Check Garage -3rd story, 2 exits
3.
Ftg., Garage; Soils -Steel- / /" Ftg. Depth
50.
Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection
4.
Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth
51.
Plywood on Roof Overhang -Attic Vents -Rafter Outriggers
5. Stemwalls, Main; Steel -Blackouts -Wrapped -Slab
6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab
52.
53.
Siding -Nailing -Veneer
Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access
-
7.
8.
Piers -Fireplace Ftq.-Steel
D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test
54.
55.
Glazing Area -Glass Protection -Skylights -Plastic
Shear Walls; Nailing -Bolts
9. Gas Pipe; Size -Anchors
10.
Water Pipe; Test -Anchors -Regulator -Service Test
11.
Electric; Underground
12.
13.
Plenums & Ducts; Clearance -Material -Support -Ins.
Girders -Sills -Anchor Bolts -Joists -Vents -Cripples
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Date Card -BI Date
Date
FINAL (Plans) OK except #'s
56. Ext. Steps -Door & Sidelight Protection -Landings
57. Smoke Detector
Card -BI
Date
PLUMBING
14.
Date Card -BI Date
(Permit) OK except #'s
Water Ht.; Vent -Access -Combustion Air
58.
59.
Furnace; Vents -Clearance -Comb. Air -Connector -
In Garage; Above Floor -Ducts -Meth. Protection
Bedroom Exiting -
15. Water Pipe; Test & Anchors -Nail Protection
16. D.W.V.; Test-Fttngs & Anchors -Nail Protection
_
17.
Shower Pan; Test, First Floor -Tub Access
60.
G.F.I. & Bath Fixtures & Tub Access
18.
Test Tub & Shower, 2nd Floor -Tub Access
61.
Elec. Trim & Subpanel; Breaker Sizes -Labels
19.
Gas Pipe; Size & Anchors
62.
Stairs & Rails
_
63.
Fireplace or Stove; Clearances -Hearth
64.
Elec. Outlets at Wood Panel; Int. & Ext.
Card -BI
Date Card -BI Date
65.
Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance
Card -BI
Date Card -BI Date
66.
Elec. Outlets & Receptacles at Kit. Counter
Date
ELECTRICAL(Permit) OK except #'s
67.
Garage Fire Door; Swing -Landing -Closer
68.
A.C. Duct in Garage -Damper
---
20.
Fixture & Transformer Clearance -Ins. Protection
69.
Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.-
In Garage; Above Floor -Meth. Protection
21.
Receptacles Spacing -Lights &Switches at Doors
70,
Plb., Elec. & Mech. Equip. Listed for Location
22.
Size
Size
SBoxes & No. of Conductors -Stapled
71.
Elec. Receptacles in Garage; (G.F.I.)-Romex Protec.
23. Ramex Installed Close to Edge of Studs & C.J.
-
24.
Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water
72.
Insulation -Foam -Looked in Attic E] Yes
25.
2 Appliance Circuits in Kitchen & Conductor Size
Guard Rails & Deck Construction -Post Caps
-
26.
Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or AI
74,
Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance
Looked under Floor ❑ Yes
--
27.
Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or At,
Insulated Neutral JYes ❑No
75.
76.
Following in ❑]Ye Drive E] Yes E] No; Walks ❑Yes E3 No;
Planters Yes ❑No
Stucco; Brown -Finish
28. Service -Riser Conductors & Ground -Main Disconnect
-
29.
Equip. Clearances; Panels-Motors-Mech. Equip.
77,
A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet
_ --
30.
Clothes Closet Light -Shower Light -
78.
Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs.
--------------
---
79.
Water Well; Disconnect, Electrical, Plumbing
Card B-1
----.-
_Date- _ Card -BI -_ Date
80.
81.
Exterior Elec. Trim; G.F.I. Receptacle -Underground
Ventilation throughout House
Card B-1
Date Card -BI Date
82.
Glass Protection
Date
MECHANICAL (Perrrit) OK except #'s
83.
_
Corrections from Previous Inspections
84.
Gas Test -Meters Tagged; Gas -Electric
_-
31.
A.C_.-Ducts: Insulation & Support
85.
Water & Sewer Connected -C/O to Grade -HD Approval
32.
33.
Vent Fan; Exhaust above Insulation
Condensate Drain _& Overilow; Size & Grade
86.
Energy Compliance Certificate -Other Certificates
34.
Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet
35.
Attic Access & Platform if Furnace in Attic
Card -BI
Card -BI
---
-- -- - -- -- ----- ---------------- -
Date Card -BI Date
Date Card -BI Date
Card -BI
Date Card -BI Date
Card -BI
Card -BI
Date Card -BI Date
Date Card -BI Date
Date
FRAMING(Plans) OK except #'s
Comments at Final:
36.
Sills; Proper Material & Anchors
37.
38.
39.
-Walls:-Studs-Nailing, Spacing & Bracing -Plates -Sound
Bearing Walls over Girders & Floor_ Nailing__ _
Draft Stop in Walls (rat proof) _
_
_
40.
41.
42.
43.
44.
45
46.
47.
_Fire Stops; Furred Ceilings -Stairs -Chases -Tub
Header & Beam -Size & Bearing
Hangers -Post Caps -Anchors -Connectors
Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthnq.-Rfng.
Fireplace Ties or Type A Flue -Fireplace Throat
Attic Access; Size & Rom_ex Protection -Draft Stop -Ins. Baffles
Bdrm. Windows or Exiting -Doors-Sill Hgt. & Dimensions_- -
Garage Fire Protection Framing
(NOTE: An entry must be made each time youvisit jobsile)
COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS
7 County Center Drive - Orovil)e, California 95965 - Telephone 916/534-4541
APPLICATI6N AND PERMIT
PERMIT NO.
AA
ASSE SO ARCEL UMBER„
r
ZONING
BUILDING PERMIT
OWNE
TELEPHONE
SO. FT. OCC. BUILDING VALUATION
V
Y -'may
OWNER'S AILING ADDRESS
CON RACTOR'S NATAE -
TELEPH E
I.
CONTRACTOR'S MAILING ADDRESS
9 &1"1Fireplace
CO STRUCTIO LENDER fUNKN
Total Valuation $
Filing Fee
$ 10.00
LENDER'S MAILING ADDRESS
Permit Fee
$ Q.
ARCHITECT OR ENGINEER
LICENSE NO.
Plan Checking Fee
$ �^
Penalty
$
ARCHITECT OR ENGINEER'S MAILING ADDRESS •
Permit fee
$
BUILDING ADDRESS
Y_ r
PLUMBING PERMIT
Filing Fee 10.00
Each Trap
2.00
Solar Water Heater
20.00
Water piping
5.00
LOT NO.
SUBDIVISION NAME
PARCEL MAP
Each qas water heater or vent
5.00
Gas piping system 1 - 5 outlets
5.00
USE OF STRUCTURE
SF ❑ Duplex ❑ Mobi lehome � Other
SPECIFY
Building sewer
5.00
Mobile Home Fs -F G FWT
110-00e
TYPE OF WORK
New ❑ Addition � model ❑ tilities ❑ Installation❑ Other ❑
Describe work: E3 Ib V e — —
Permit Fee
$
Contractor
ELECTRICAL PERMIT
Filing Fee 10.00
Main service 600V OR LESS
100 AMP OR LESS
10.00
Main service EA. ADD'L 100 AMP
2.50
NEW CONST. DWELLING OCCUP.&
OR ADDNS. ACC. BLDGS.
2I/ZQSgft
CONTRACTORS LICENSE LAW
I declare under penalty of perjury (check One):
[�I am licensed under provisions of Chapt. 9, Div. 3 of the Business
and Professions Code and my nlicese is in full forCo an effect.
License No. 7 Classification Cr
❑ I, as the owner, or my employees with wages as their sole compen-
sation, will do the work,and the structure is not intended or offered
for sale. (Sec. 7044)
❑ I, as the owner, am exclusively contracting with licensed contract-
ors. (Sec. 7044)
❑ I am exempt under Sec. , Business and Professions Code
for this reason
NEWCONSTR. MULTI -OUTLET 2,50 ea
NO N.R ESI D, BRANCH CIRC ITS
NEW CONSTR. POWER APPARATUS &
NON.RESI D. (SINGLE OUTLET CIR.
20ee0a
Ex. Occup(O TS OR FIXTURES BAL®30Q
FIXED
EX. OCCup. OUTLETS P(RESID )REA.) 2.00
Temporary service 10.00
Mobile Home Facilities 15.00
Misc. Wiring 15.00
Permit Fee $
Contractor
MECHANICAL PERMIT
FiIingFee 10.00
WORKMEN'S COMPENSATION INSURANCE
I declare under penalty of perjury (check one):
❑ The permit is for $100.00 (valuation) or less.
I have placed on file with the County of Butte Building Department
a Certificate of Workmen's Compensation Insurance or a Certificate
of Consent to Self -Insure.
❑ I shall not employ any person in any manner so as to become subject
to the W. C. laws of California.
Notice to Applicant: If after making this statement, should you become subject
to the W. C. provisions of the Labor Code, you must forthwith comply with such
provisions or this permit shall be deemed revoked.
Heating
Cooling
Hood
3.00
Ventilation
permit Fee
$
Contractor
I certify that I have read this application and state that the above information
is correct. I agree to comply to all County Ordinances and State Laws relating
to building construction, and hereby authorize representatives of the Countyot
Butte to enter upon the above-mentioned property for inspection purposes.
I also agree to save ' derofify and keep harmless the County of Butte against
all liab' ties, j nts costs, and expenses which may in a way accrue
agai s n C s ence of the granting of this perm)
X Date
Signature of AIVIC.Ilkl Owner❑ Contractor-- Agent ❑
An OSHA permit is required for excavations over 5'0" deep and demolition or construct-
ion of structures over 3 stories in height.
Mobile Home Installation Fee
$
ov
TOTAL PERMIT FEE $
OccuP. GROUP
M'—/
I TYPE OP oNST.
PARC L
P
HD ss E
This permit is hereby issued under
sions of the Butte County Code and/or
work indicated above for which
DIRECTO PUBLIC
BY
PE T EXPIRES Date
the applicable provi-
resolutions to do
fees have been paid.
WORKS
ate
Receipt No.Y-
WHITE-D.P.W., YELLOW-ASSESSOR,���PINK-INSPECTOR, GOLDENROD -APPLICANT