Loading...
HomeMy WebLinkAbout065-410-002� ON 65-41-02 ]ag ack Pine, lot 26,, Unit 3,11 ontr Joh enry Const;-Magali—Perm t#2755-8 � E(util, MH) ELEC 0-7-�ZGASCOMPACTION TEST REQ "PSTRUCTUR. EQ65-41-02 M Contra: �aradis8 Modular Concepts .?P� mit#2566-84MHI Sued 9 � 4/ �W � s Cc 65-41-0' ontr ` PMC 1 Permit #2685-84B (decks/MH) �.tA�w" ?v 065-410-002 99-0620 SIMONS, Ila !'r 15060 Jack Pine Way, Magali Contr: Zink's Remodel Ex MH on Perm Fnd ' I 1 •' I • o f j o f t - � � � 3� I NOTES _..RESIDENTIA1_ _ r 065-410-002 99-0620 ' SIMONS, Ila PE IT NO.j:.....15060 Jack Pine Way, Magalia..-. Contr: Zink's Remodel Ex MH on Perm Fnd _ 26 4 THE HCD FORM 4- i A FOR THIS MH CANNOT BE RECORDED UNTIL ONE OF THE FOLLOWING HAVE BEEN TURNED IN TO THE BLDG DIV: (1) LICENSE PLATE(S) or DECAL(THE INSPECTOR MUST RETRIEVE) (2) STATEMENT OF FACTS(ONLY ON NEW MH'S) INSPECTOR TO VERIFY SERIAL & LABEL #'S 11 SPECIAL CONDITIONS -11 SRA _ FLOOD CERTIFICATE REQ. _ FIRE SPRINKLERS REQ. SPECIAL INSPECTION ITEMS _ VERIFY USE PERMIT CONDITIONS SUB -STANDARD HOUSING LETTER CHECKED BY ' JOB FINALED (Date) Signature ./= OK 0 = Not OK - = Not Applicable = Not Ready RESIDENTIAL (; Date FRAMING (Continued) Underfloor (Plans) OK except #'s 46. 1. Zoning -Setbacks -Easements -Flood -Slope 47. 2. Ftg., Main; Soils-Elec. Grnd.-/ /" Ftg. Depth 48. 3. Ftg., Garage; Soils-Steel-Elec. Grnd.-/ P Ftg. Depth 49. 4. Ftg., Porches & Decks; Soils -Steel-/ /" Ftg. Depth 50. 5. Stemwalls, Main; Steel-Blockouts-Wrapped 51. 6. Stemwalls, Garage; Steel-Blockouts-Wrapped 52. 6a. Hold Downs and Special Anchors 53. 7. Slab, Steel -Wrapped 54. 8. Piers -Fireplace Ftg.-Steel 55. 9. D.W.V.; Fall -Fitting -Test -2 Way C/0 -Sewer Test 56. 10. UF, Gas Pipe; Size Anchors - Yard Gas Piping; Size Test 57. 11. Water Pipe; Test -Anchors -Regulator -Service Test 58. 12. Electric Underground 59. 13. Plenums & Ducts; Clearance -Material -Support -Ins. 60. 14. Girders -Sills -Anchor Bolts-Joists-Vents-Crippies 61. 15. Access & Ventilation 62. 16. Insulation Date Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s PLUMBING (Permit) OK except #'s 63. 17. Water Htr.; Vent -Access -Combustion Air Baffle 64. 18. Water Pipe; Test & Anchor -Nail Protection 65. 19. D.W.V.; Test Fittings & Anchor -Nail Protection 66. 20. Shower Pan; Test, First Floor -Tub Access 67. 21. Test Tub & Shower, Second Floor -Tub Access 68. 22. Gas Pipe; Sixe & Anchors 69. Stairs & Rails Date Fireplace or Stove, Clearance -Hearth Card B-1 Date Card B-1 Date Elec. Outlets at Wood Panel, Int. & Ext. Card B-1 Date Card B-1 Date Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance ELECTRICAL (Permit) OK except #'s 73. 23. Fixture & Transformer Clearance -Ins. Protection 74. 24. Elec. Receptacles Spacing -Lights & Switches at Doors 75. 25. Size Boxes & No. of Conductors Stapled 76. 26. Romex Installed Close to Edge of Studs & C.J. 77. 27. Equip. Ground made up w/Mech Fasteners -Bond Gas & Water 78. 28. 2 Appliance Circuits in Kitchen & Conductor Size GFI 79. 29. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga Cu or AI 80. 30. Range Circle / / ga Cu or AI -Oven Circ. / / ga Cu or At Insulated Neutral p Yes ❑ No 81. 31. Service -Riser Conductors & Ground Main Disconnect 32. Equip. Clearances Panels-Motors-Mech. Equip. 82. 33. Clothes Closet Light -Shower Light -Spa Light 83. 34. Smoke Detector 84. A.C. Unit Disconnect, Electrical -Plumbing Date Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings Card B-1 Date Card B-1 Date Water Well, Disconnect, Electrical, Plumbing Card B-1 Date Card B-1 Date Exterior Elec. Trim, G.F.I. Receptacle -Underground MECHANICAL (Permit) OK except #'s 88. 35. A.C. Ducts Insulation & Support 89. 36. Vent Fan, Exhaust above insulation 90. 37. Condensate Drain & Overflow, Size & Grade 91. 38. Furnace -Vent Access -Comb. Air -Return Air Vent 115 outlet 92. 39. Attic Access & Platform if Furnace in Attic 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 FRAMING (Permit) OK except #'s Card B-1 Date Card B-1 40. Sits Proper Materials & Anchors 41. Walls Studs -Nailing Spacing & Braces -Plates -Sound 42. Bearing Walls over Girders & Floor Nailing 43. Draft Stop in Walls (rat proof) 44. Fire Stops, Furred Ceilings -Stairs -Chasers -Tubs 45. Headers & Beams -Size & Bearing jingle & Duplex) Date FRAMING (Continued) 46. Hangers -Post Caps -Anchors -Connectors 47. Cling. Joist-Rftr. Ties-Purlin-Roll Brac.-Truss-Shting.-Rfng. 48. Fireplace Ties or Type A Flue -Fireplace Throat Clearance 49. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 50. Bdrm. Windows or Exiting Doors -Sill Ht. & Dimensions 51. Garage Fire Protection Framing 52. Property Line Firewall & Openings 53. Ext. Doors -One 3' -Check Garage 3rd Story, 2 Exits 54. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 55. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 56. Siding -Nailing Veneer 57. Stucco Mesh -Drip Screed -Fd. Vents-Underflr. Access 58. Glazing Area -Glass Protection -Skylights -Plastic 59. Shear Walls; Nailing -Bolts 60. Brace Interior/Exterior Wall Panels 61. Insulation -Walls -Ceilings 62. Infiltration -Walls -Windows Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 63. Ext. Steps -Door & Sidelight Protection -Landings 64. Smoke Detector 65. Furnace Vents -clearance -Comb, Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 66. Bedroom Exiting 67. G.F.I. & Bath Fixtures & Tub Access -Spa 68. Elec. Trim & Subpanel, Breaker Sizes & Labels 69. Stairs & Rails 70. Fireplace or Stove, Clearance -Hearth 71. Elec. Outlets at Wood Panel, Int. & Ext. 72. Kit. Fixt. & Appliance; Ground -Air Gap -Cooking Clearance 73. Elec. Outlets & Receptacles at Kit. Counter 74. Garage Fire Door; Swing -Landing -Closure 75. A.C. Duct in Garage -Damper 76. Wtr. Htr.; Vents -Clearance -Comb. Air Connector-P.R.V. in Garage; Above Floor-Mech. Protection 77. Plb., Elec. & Mech. Equip. Listed for Location 78. Elec. Receptacles in Garage (F.F.I.)-Romer. Protection 79. Insulation -Foam -Looked in Attic 80. Guard Rails & Deck Construction -Post Caps 81. Fdn. VBents & Crawl Hole Door Drainage & Wood -Earth Clearance Looked under Floor O Yes 82. Following Instld./Drive J Yes 0 No/Walks ❑ Yes 0 No/Planters ❑ Yes ] No 83. Stucco Brown -Finish 84. A.C. Unit Disconnect, Electrical -Plumbing 85. Vents Above Roof, Plbg-Appliance-Fireplace-Clearance to Openings 86. Water Well, Disconnect, Electrical, Plumbing 87. Exterior Elec. Trim, G.F.I. Receptacle -Underground 88. Ventilation Throughout House 89. Glass Protection 90. Corrections from Previous Inspections 91. Gas Test -Meters Tagged, Gas -Electric 92. Water & Sewer Connected -C/O to Grade -HD Approval 93. Energy Compliance Certificate -Other Certificates 94. Address Posted Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Comments at Final: ./ = OK 0 = Not OK - = Not Applicable . MOBILE HOMES = Not Ready Date MOBILE HOME UTILITIES (Plans) OK except #'s Zoning Requirements -Setbacks -Easements 1. Zoning Requirements -Setbacks -Easements 3. 2. Soils; Special MH Support Sketch Wood Awn.; Posts- Beams- Rftrs.-Con nectors Shthg.-Frg-Bracing 3. Sewer; Location -Test -Fall -C/O -Concrete 6. 4. Water; Location -Test -Easement Needed (Sketch) Ext.; Steps -Doors -Landings 5. Electricity; Location-Clearances-Grnd-/ /Amp -Concrete Braced Wall Panels 6. Gas; Location -Test -Wrap;-/ /" L'ft. / P Nat. or / /"L"ft./ /'LPG 7. Well Clearance 8 Disconnect Card B-1 Date Card B-1 8. Utility Clearance Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date MOBILE HOME INSTALLATION (Plans) OK except #'s 4. 1. Zoning Requirements -Setbacks -Easements 5. 2. Footings; Size -Spacing -Marriage Line 6. 3. Gas; MH Test -Demand -Valve -Connector 7. 4. Electricity; MH Test -Crossovers -Breakers -Clearances 8. 5. Drain; MH Test -Fall -Flex Connector 9. 6. Water; MH Test -Regulator -Connector 10. 7. Water and Sewer Connected -C/O to Grade -HD Approval 11. 8. Gas and Electricity Tagged 9. Tie Downs -Type -Installation Cert. 10. Exits; Insp.-Sketch 11. Cert. of Occupancy 12. Permanent Foundation Only; License Decal Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 'MISCELLANEOUS Date DECKS, COVERS, CARPORTS GARAGES (Plans) OK except #'s 1. Zoning Requirements -Setbacks -Easements 2. Footings; Soils -Size -Depth -Spacing -Connectors -Steel 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Wood Awn.; Posts- Beams- Rftrs.-Con nectors Shthg.-Frg-Bracing 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Carports; Windows -Doors 7. Electric 8. Frmg.; Sills-Anchors-Studs-Rftrs-Trusses 9. Siding; Nailing -Veneer -Stucco -Mesh 10. Roof; Shthg-Roofing 11. Ext.; Steps -Doors -Landings 12. Braced Wall Panels Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 Date FINAL (Plans) OK except #'s 1. Setbacks -Easements 2. Soils; Compaction -Structure Stability 3. Pool Structure; Steel -Connections -Thickness Dead Men -Lining 4. Elec.; Receptacles and Lighting, Distance-GFI 5. Elec.; Pool Lighting; 15 Volts-GFI 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Elec.; Bonding; Metal w/5' -Circulating Equip. -Heater 8. Elec.; Grounding; Equip. w/5' Circulating Equip. -Pool Lghtg. Boxes- Enclosures- Panelboards-Ins. to Main in Conduit 9. Health Department Approval 10. Plumb.; Cir. Test -Water Supply Test 11. Light Niche Date Card B-1 Date Card B-1 Date Card B-1 Date Card B-1 COUNTY OF BUTTE BUILDING DIVISION DEPARTMENT OF DEVELOPMENT SERVICES 411 Main Street • Chico, CA • (530) 891-2751 7 County Center Drive • Oroville, CA • (530) 538-7541 . CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of butte county Ordinances exist at the above address and should be corrected. Please notice this office when correction of work is completed. If you have any questions pertaining to this matter, or need additional explanation, please contact this office immediately. o 0C Po J� r- k Lf. ' t j nj r -7 i Date y/-)0/ yf Inspector REV 10/92 �i►� !l ` V COUNTY OF BUTTE - DEPARTMENT OF DEVELOPMENT SERVICES - BUILDING DIVISION 7 County Center Drive • Oroville, ralifornia 95965 • Telephone (530) 538-7541 PERMIT NO. (Rev. 12/96) APPLICATION AND PERMIT ASSESSOR PARCEL NUMBER 065-410-002 ZONING BUILDING PERMIT � OWNER SIMONS, ILA Tfff-1636 SO. FT. OCC. BUILDING VALUATION 1440 80,640.00 . OWNER'S MAILING ADDRESS 15060 JACK PINE WAY, MAGALIA 95954 CONTRACTORS NAME ZINK' S REMODEL ELEPHE T532 -6464 CONTRACTORS MAILING ADDRESp .0. BOX 9281, CHICO 95927 I' ' CONSTRUCTION LENDER Fireplace LENDER'S MAILING ADDRESS Total Valuation $ 80-640.00 ARCHITECT OR ENGINEER LICENSE NO. Filing Fee $ 20.00 Permit Fee 554/2 $ 277.00 ARCHITECT OR ENGINEERS MAILING ADDRESS Plan Checking Fee $ 2300 BUILDING ADDRESS Energy Plan Checking Fee $ $ PERMIT FEE $ 320.00 LOT NO. SUBDIVISIONS NAME PARCEL MAP PLUMBING PERMIT Fling Fee 20.00 Each Trap 7.0023.00 USEOFSTRUCTURE SF ❑ Duplex ❑ Mobilehome ❑ Other SPECIFY Solar or heat um water heater Water piping 15.0019,00 Each as water heater or vent 15.00 TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Ublities ❑ Installation ❑ Other ❑ Describe Work: EXISTING M/H ON PERM FOUNDATION Gas piping system 1 - 5 outlets 15.00 L5.00 Building sewer 15.00 Mobile Home IS I GI W @20.00 PERMIT FEE $ 50.00 ELECTRICAL PERMIT Fling Fee 20.00 Main Service zo.A OR LESS 23.00 LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my license is in full force and effect. G `/, License Class f7 Lic. No. (a �J r`%N•� OWNER -BUILDER DECLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the following reason: ❑ I, as owner of the property, or my employees with wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ❑ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project. ❑ 1 am exempt under Sec. Business and Professions Code for this reason Main Service 200A TO 1000A 46.00 NEW CONST. DW ELJNG CUP. SO OR ADONS. ( a ACC. BLDS. 3.5¢FT. „ON N'-ROp ' MULTI.OLmEr @7,50 POWER APPARATUS a SINGLE OLmET R. 20 .00 EX. Occup. OUTLET OR FIXTURES BAL @ I.50 Ex. Occup. ou�TLEEDTs A9 o.OFRn 5.00 Temporary Service 23.00 Mobile Home Facilities 20.00 Misc. Wiring 23.00 PERMIT FEE $ WORKERS' COMPENSATION DECLARATION 1 hereby affirm under penalty of perjury one of the following declarations: ❑ 1 have and will maintain a certificate of consent to self -insure for workers' compensation, as provided for by section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain workers' compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Carrier Si -s Cum ID iAsc.' Policy Number 12, - 9 ? U V1 i 551 (The above sections need not be completed if the permit is for work of a valuation of one hundred dollars ($100) or less.) ❑ 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to workers' compensation laws of California, and agree that if 1 should become subject to the workers' compensation provisions of section 3700 of the Labor Code, I shall forthwith comply with those provisions. 49 hh X ��� /D4te `'t - Signature of Applicant - ❑ Owner 13 Contractor ) Agent An OSHA permit is required for excavations over 60" deep` and demolition or construction of structures over 3 stories in height. MECHANICAL PERMIT Fling Fee 20.00 Heating Cooling Hood 6.50 Ventilation PERMIT FEt $ Mobile Home Installation Fee $ Energy Inspection Fee $ Occ CONST. TYPE TOTAL FEE $ i 7f Z. D. FEES M FLOOD 1,6F IPAR HD SUE This permit is hereby issued under the applicable provisions of the Butte County Code and/or Resolutions to do work indicated above for which fees have been paid. By ate l PERMIT EXPIRES ON -( �0 Date Receipt No. 264579/$63.00// G Q WHITE-D.D.S.-B.D. CANARY -ASSESSOR PIN -INSPECTOR GOLDENROD -APPLICANT 'COUNTY OF BUTTE DEPARTMENT OF DEPEEOPMENTE VICES - BUILDING DIVISION 7 COUNTY CENTER DRIVE - OROVILLF tCAlg9R A 95965 - TELEPHONE (916) 538-7541 PERMIT APPLICATION DATA SHEET OWNER: S ( M (bpi s ASSESSOR PARCEL Proposed Building Use;C m)JI DIgemA- ing Inspector: 4adl e: L/ / At time of permit applicitionA was a ' ed the following data must be submitted prior to permioroce6ing an or issuance: Date Received By ❑ 1. All items have been submitted ----------------------------------------------------------------------- --------------- ❑2. Plot plans, 3/4 sets, signed by the preparer of plans. ------------------------------------------------------------ ❑ 3 . Complete plans, 3/4 sets, signed by the preparer of plans. ----------------------------------------------------- 04. Engineered plans, 3/4 sets, with wet signature on plans. All engineering must be shown on plans. -------- ❑ 5. Engineered truss details and layout in duplicate (required prior to plan review) No faxes! ------------------ ❑ 6. Energy Design Compliance and supporting documentation. - - ❑ 7. Statement of Intent for Non -Heated and A/C Buildings. ------ 118. ----- ❑8. Hazardous Material Form. ufactured Home data and installation instructions including Tie Down Specifications. ------------------ c F s of $ --------------------------------------------------------------------------------.pact fees as shown on the attached schedule.--------------------------------------------------------------- ❑ 12. California Department of Forestry plan approval/fees-------------- ❑ 13. Flood elevation certificate. --------------------------------------------- 0 14. Sanitation and plot plan approval Health Department. ❑ 15. City of Chico plumbing permit ----------------------------------------- 1116. ---------------------------------------- ❑16. Plot plan and business license approval from the City of Biggs. --- 7. Planning approval for (A) Use: 0k- i (B) Parking: _ ❑ 18. Contact Land Development about ❑ Improvements, ❑ Drainage, ❑ Legal Parcel. ❑ 1.9.'Encroachment Permit for driveway (construction approval prior to occupancy). --- ❑20. Pre -inspection for required Request to Building Inspector on ❑21. Contractor's license information. (Number, Name Style, Classification). ---------------------- =------------- ❑22. Workers' Compensation carrier and policy number. -------------------------- =-------------------------------- ❑23.Owner-Builder Verification (Given to owner ❑, Mailed to owner 0) - -------------------------------------- 024. Letter of signature authorization. ---------- ---------------------------------------------------------------------- E125. Recorded copy of Agricultural Acknowledgment Statement. -------------------------------------------------- ❑26. Letter of intent on building use.----------------------------------------------------------------------------------- El 27. Manufactured Home utility clearance. ---------------------------------------------------- ---------------------- -7- El 28. E sting violations and/or aZped permits. --------------------------- . ---------------- ---------- R2933 rrant DeedH. Titl to H.C.D $—__J� -- - ------- ❑30.Other: _______ (Date) 2en you issue the permit, process asfo ows 11 Mail to owner, ❑Mail�ttgVnnytractor. e,elephonS- 9, 6 4(eland hold for pickup at f—(J _office. ❑ Deliver with inspector. Applicant: Date: Copy of Haz-Mat form sent o Health Department, ❑ Fire Department, ❑ Air Pollution Date. By: Copy of plans sent o Health Department, ❑ Fire Department, o Othe Date: By. 1. Index permit application for the above items numbered: Xe ❑ Plan Check List 2. Additional items required: Contractor, designer, owner, was advised of the above required data by o pone, ❑ mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by o phone, ❑ mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by o phone, ❑ mail, o Building Division counter, by Date: Contractor, designer, owner, was advised of the above required data by o phone, ❑ mail, o Building Di n counter, by `e Plans reviewed by: Date: Plans approved by: Date: Sets of plans on hold in ❑ Plan Cabinet, ❑ A.P. folder. Note transfer by: Date: Yellow Copy - Department of Development Services, Building Division. MAR -23-1999 15:34 BUTTE COMMUNITY BANK 530 899 7490 P.02/03 f oivi 1701. -?hQLrLLL MW OTMOMMIN A This set of plans kept on the I ob at aD tees and it . is unlawful to make any changes or alterations on same -without the DWtr=OA of PubliO written permiv>iOn from Omnie cc But". IqOTF,: All Materials & Workmanship shall Be TA at�-ordance Recognized Good Practices and I of 'ty Prescribed for the specified use in Plumbing & M60hwAca- thNb'j�p ,gorm Building, Codes . We. I A. MW — 'ING DEPAR7 A, P I r "ids _(ft.) Box Length_(ft.) Tagalong or Expando Size ft. M, �� ft. ''(SHM SUPPORT DETAILS BELOW) J hM all wobilehomes manufactured after October 7, 1973, furnish manufacturers installation saaual and structural setup sheets (if not on file with the County of Butte). .11 center supports measured from front of obilehame unless otherwise specified. one) (� Singe L ._�1' .� i1 !sU�";M VA . �. , _ E • . ]. • WO either AA:: pressure ;treated c i n _ - foundations grade. ter piers are other than drawn above, n locations, spacing, and dimensions. 2. Others (specify) (check one) Concrete block. •2. Other. (specify) Tagalong or Expando,• show support details. J -- Typical Support n.) Footing Size -- Max. Pier Spacing . (ft -)(in.) -- Max. Overhang (ft.)(in.) BUTTE COUN7-� A P P R 0 V F 4 i REC6RD.1NG REQUESTED BY: AND WHEN RECORDED MAIL TO: BUTTE COUNTY BUILDING DIVISION 7 COUNTY CENTER DRIVE OROVILLE CA 95965 1 999-00 1 90 1 6 Recorded I REC FEE .00 Official Records I CONFORM .00 Countyyf (530)538-7541 BUTTE I CANDACE J. GRUBBS I Recorder I ROSEMARY DICKSON I Assistant I Nikki 01:28PM 04 -May -1999 I Page 1 of 2 SPACE ABOVE THIS LINE FOR RECORDER USE ONLY NOTICE OF MANUFACTURED HOME (MOBELEHOME) OR COMMERCIAL COACH, INSTALLATION ON A FOUNDATION SYSTEM Recording of this document at the request of the local agency indicated is in accordance with California Health and Safety Code Section 18551. This document is evidence that such local agency has issued a certificate of occupancy for installation of the unit described hereon, upon the real property described with certainty below, as of the date of recording. When recorded, this document shall be indexed by the county recorder to the named owner of the real property and shall be deemed to give constructive notice as to its contents to all persons thereafter dealing with the real property. ILA A. SB4N10NS REAL PROPERTY OWNEMESSOR 15060 JACK PINE WAY MAILING ADDRESS MAGALIA, BUTTE, CA 95954 CITY COUNTY. STATE ZIP SAME INSTALLATION MAILING ADDRESS, IF DIFFERENT CITY COUNTY STATE ZIP SAME UNIT OWNER (if also property owner, write "SAME") MAILING ADDRESS CM COUFY STATE AP UNIT DESCRIPTION BUTTE COUNTY BUILDING DIVISION LOCAL AGENCY ISSUING PERMIT and CERTIFICATE OF OCCUPANCY 7 COUNTY CENTER DRIVE MAILING ADDRESS OROVILLE, BUTTE, CA 95965 CITY COUNTY STATE ZIP 99-0620 (530)538-7541 BUILDING PERMIT TELEPHONE NUMBER SIGNATURE OF LOCALXrY OFFICIAL DATE NONE DEALER NAME (if not a dealer sale, write "NONE") DEALER LICENSE NO. GOLDEN WEST 1983 KINGSTON MANUFACTURER'S NAME DATE OF MANUFACTURE MODEL NAMENUMBER GW6CALKG5333A/B 60'X 24' CAL264997/8 SERIAL NUMBER(S) LENGTH X WIDTH INSIGNIMI.ABEL NUMBER(S) REAL PROPERTY LEGAL DESCRIPTION ASSESSOR'S PARCEL NUMBER SEE ATTACHED A.P. #065-410-002 HCD FORM 433(A) REV. 8/91 WHITE -County Recorder CANARY - HCD PINK - Applicant GOLDENROD- Building Dept. LEGAL DESCRIPTION A.P. #065-410-002 All that certain real property situate in the County of Butte, State of California, described as follows: Lot 27, as shown on that certain Map entitled, "PARADISE PINES UNIT NO. 3", which Map was recorded in the Office of the Recorder of the County of Butte, State of -California, on June 17, 1970, in Book 35 of Maps, at Page(s) 78, 79, 80,'81 and 82. EXCEPTING THEREFROM all of the valuable minerals beneath the surface of the said lands, with the right to mine and extract said minerals, it being agreed and understood that in all mining operations, the surface of said lands will be protected against damage and that all such mining shall be carried on from tunnels, shafts or drifts having their orifices outside of the surface area of the above described realty, all as excepted and.reserved in the Deed from Magalia Mining Company, A Corporation, to E.D. Storts, Et Ux, recorded September 4, 1947, in Book 423, Page 385, Official Records. BUILDING PERMIT NUMBER: 99-0620 Address or location of unit: 15060 JACK PINE WAY, MAGALIA, CA 95954 Legal Description of Real Property: A.P. #065-410-002 SEE ATTACHED (x) Mobilehome/Manufactured Home O Commercial Coach Has been affixed to the real property above by installation on a foundation system pursuant to Health and Safety Code Section 18551. Owner's name: ILA SIMONS Owner's address: 15060 JACK PINE WAY, MAGALIA, CA 95954 INSIGNIA OR HUD NUMBER: CAL264997/8 SERIAL NUMBER OR V.I.N.: GW6CALKG5333A/B 'MANUFACTURER'S NAME: GOLDEN WEST YEAR: 1983 OFFICIAL APPROVING INSTALLATION: DATE: 5/3/99 PHONE: (530) 538-7541 H.C.D. 513C May -07-99 15:47 BUTTE COMMUNITY BANK"103 530 873 0763 P_01 n L- ,47 L o v it -F y ife e OBD v,"//c- Ccti l4 TT- 4/ -c -4 -No CJ if/Cury %tC c ✓�c� a Rc,ls7�^�7ivrt Gomr�t(";ti� j.17e uc I01�izIc11 5�4-1tc c+ATDyHi� - AL 67; o-"018"3. whe`7: geCc.��c( A)a 5 ee._ o 30. vc> S e :, of Yo OL- C v Me Xe -9 t S4 rL�L � i ' o k ll L'c,r-& po i r7od r/e, l,o,vt��.S &J I-cb( r.5 v.,1�/ `f 4Je v:.,r )Cc 4 1,c �iCv.5r�•iq .� Cd�vlivrv�'IIT�/ •�cei�. �Upl�7P..�'� Tli�c �.i � yfJ!/' .Ili¢ S; H2O1t � •• � MAR -24-1999 15:49 BUTTE CGWUN I TY BANK 530 899 7490 P.02/03 WDUEBM BY 00 VALM 1= 818 6 71 94-0182861 a" Fee 9.00 a 9.00 WHOM V400AM MR. M Recorded 56M SANOW afficast Records I ILA es I 10W JACK FM WAYCounty Y Butte I MAGAUA. CA SIM CandacW 3, ftubbe I Recorder I GsWaix JR 2 MAL TAX MAM30M T42 OOglli@ILYM17p TAX ids SAW AmABOVE on."S.-M abr ]bedlogo IR�dMima,,,—+— �� pe 2A agm smaks.A sm" vwnm XALONOW-AsvW=43FTmoAL'8.MKMf4EVOCAiLE VMVN0SjRUSTDAjWDECBAgER "Noplep PORAM AREA and .tiYidCeblslRreslslat SWUM& DCXMWnM ATMC=.NEf�El AM ME A PMF -no =mama Lmm nw.. it a . 1191, Datod STATE CP C.%P:0RM COUNTY OF RUTTR 0o APItIlL 22, MBE ollw OL - a 406wod 1!11 w.ld*P jumm %%m ma"aw ft ow so" 6b NL*mmw 1W.1v matmopkw • wo PW 40 404 SWWAW M Wilm"d MellltiBl;r bW OW dkW mak IIA IRENE SIMONS mWq- _041110 0 . ste WI:TE WMVV v Y313 MAR -24-1999 15:50 BUTTE COMMUNITY BANK 530 899 7490 P.03iO3 .•_ .�, `'-n�-.111 �i 5.s�i_a:�;.�.�.wwr..._,_�_ae4r�• _ .. may• _ .y _ __ _ d 1 awl 9�-t8�$6 �• A= "M -Comm ML rAiOUPDCir 011WAT8 ng TM STATS OF CALUORMIA, CORN" *63! '8UY'!E� O�I88D. AS POLtDiiSt _M RI,. AS St[BRII OS.mw C.RO' m oup ,. NPAt1ADIS8 PIiO3S um ' �: ice,. �' �P WI$ 'O Zi 'ilia OFl.LCBOP • THB' ieSOpIiDSTt O� � OOQtl �►. bi1lPd, 8T11T8 •OF �,. Go � .17, ' 1970. M D= • 35 OF !LAPS, " VAW4S) 788' 19, SO; U ARD 82. . 8XC6lr6 mums m AM OF I= VRXZABLB-MMUERnS 11311 TH '1'lOS BORlgi= OF TUB SAID ULM, ' iirm TBE Rxcw TO !!Ilia ARD RMACT SA MAID .PRNZ , IF • MMM Aar880 AND tll oftsloon YBAT Xm- . ALir tC 'TBE SMWACB : Or V= lam • wxmI BS . PDO'P=80 acan ST I 0 Aim tEhT : ALL m n = MnUM • SBi1M aR :OARRIl9D = . 3mm. T , . WIAP'1'S OR RWIM WMR ORIFICLS OV ID8••OF tft SQWWF 3 ARAL OF TM -AMU pBSCRIDRD $BVW, ALL " MMMD AND RMMVED IR � 0=.' PRM MAGIILIA 1iZNM' CMAW, A CDRPORAMS, TO E. D. aTOATS, XT Wt,• 'Ra00RDED •SBPPbIP M 4, 1947, Ili BOOX 425, PADS 345, OFFICIAL Kamm=. CWD OF DOCUMENT TOTAL P.03 May -07-99 15:47 BUTTE COMMUNITY BANK�*03 530 873 0763 P.02 STATE OF CALIFORNIA -DEPARTMENT OF HOUSING AND COMMUNITY DEVELOPMENT REGISTRATION CARD MOBIL MANUFACTURER NAME/10 EHOME TRADE NAIVE MODEL I OON DOT OECAL I10. EAF546 GOLDEN WEST HOMES/09248 KINGSTON R6603AS OFS 08/10/83 08/19/83 08/27/84 spc I E PIRAIION U SERIAL NUMB I GNGCALKGS333A 8 t/INSIGNIA NUMBER WEIGNJ CAL264997 019000 LEN T1� 0000 TM 133 000144 091IN 84 YENPI U t 2 GMGCALKG53339 CAL264998 017000 000720 000144 SFp L• 3 TOTAL S FEES s PAID: 130.00 • SIMONS ILA 0 o" 15060 JACK PINE WY L s s MAGALIA CA 95954 e SIMONS ILA 0 M I A 15060 JACK PINE WY sI T L e MAGALIA CA 95954 A 0 o s 15060 JACK PINE WY u t N T e u MAGALIA CA 9S954 R S L BIC AMER c CHICO CONSUMER LN CTR G A PO BX 1289 t, 0 CHICO CA 95927 u DATE: 09/04/84 08:39:00 N C R IMPORTANT 03-258-00019 THE OWNER INFORMATION SHOWN ABOVE MAY NOT REFLECT ALL LIENS RECORDED WITH THE I DEPARTMENT THE CURRENT THOUSING IUDEVELOPMENT AGAINST DESCRIBED TITLE STATUS OF THE UNIT MAY BE CONFIRMED THROUGH THE DEPARTMENT. 0300010 PERMIT NO. 2685-84B PERMIT EXPIRES OWNER ',A S RION CONTR. PMC ASSESSOR PARCEL 65-41-02 LOCATION 15060 Jackpine Way, Magalia Temp. Power Pole Called PG&E Temp. Eiec. Service Called PG&E Temp. Gas Service Called PG&E JOB FINALED (Date) Signature I '" J.° _ ' COUNTY OF BUTTE - DEPARTMENT -.OF PUBLIC WORKS ' ' PERMIT NO. 7 County Center Drive - Oroville, California 95965 —Telephone 916/534-4541 �� C,;,,-- 3�, APPLICATION AND PERMIT ASSESSOR.PARCEL NUMBER (D J — v — ZONING - - - BUILDING PERMIT OWNERI r �jlh OA) TELEPHONE SO. FT. OCC. BUILDING VALUATION, CIN" OWNER'S MAILING ADDRESS /S 0 Eno .J r4r_t&.'1 I &,.e-. W art AG4(�b&_ (A - I C O N T F� q C 1 UT \ N NAME �� \ L} �fY 6 ✓ 0VI•ii:.a/"o RAACTOR;S TELEPHONE* f✓ jCO_'N`1T'-R) MAILING ADDRESS (—( \ _ Q S, < �, w (i �a (11X��s.a.r. p �SI� Fireplace CONSTRUCTION LENDER��� UNKNOWN Total Valuation $ Filing Fee $ 1.00 LENDER'S MAILING ADDRESS t l Permit Fee $ ARCHITECT OR ENGINEER/ - f/ LICENSE No. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ CJn, BUILDING ADDRESS ` "��&, PLUMBING PERMIT Filing Fee 10.00 (� ( Each Trap 2.00 Solar Water Heater 20.00 I Water piping 5.00 LOT NO. CX 7 SUBDIVISION N<AME � J PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUCTURE i SF ❑ Duplex❑ Mobilehome❑ Other 1 l �.....SPECIFY Building sewer 5.00 Mobile Home I S I G W 10.00e TYPE OF WORK New O" Addition El Remodel❑ Utilities[] Installation[] Other El Describe work: — -I .A n \ lj I' i \ a:•! ��J�ll GK.tY.Y -•+r' Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 100 OR LESS Main service 100 AMP OR LESS 10•00 Main service EA. ADD•L 100 AMP 2.50 NEW CONST. / DWELLING OCCUR.&\ OR ADDNS. L ACC. BLDGS. / 2I/20sq ft CONTRACTORS LICENSE LAW I declareunder penalty of perjury (Check one): ❑--� am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions Code and my license is in full)force' and effect. %'j ( License No a'� I I Classification 1 �' I,p I ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTR. MULTI -OUTLET 2.50 ea NO N.RESID BRANCH CIRC ITS NEW CONSTR. POWER APPARATUS & NON.RESID. SINGLE OUTLET CIR. Ex. Occu / 20®50e P\OUTLETS OR FIXTURES SAL®30 FIXED APPLNS. OR Ex. OCCUp. OUTLETS (RESID.) EA,/ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring' 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ Th-e'permit is for $100.00 (valuation) or less. Ca -,011 have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. FJI shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling Hood 3.00 Ventilation Permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. I also•agree to save, indemnify and keep harmless the County of Butte against all liabilities, judgments,\costs, and expenses which may in any way accrue against said 11 County in consequence of the granting of this permit. X— 1iu/1n \� �� c�' IV /3V _ Date "� Signature of Applicant — Owner❑ Contractor ❑ Agent ❑ ( An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 33storiesi-n]height. Mobile Home Installation Fee $ tJ TOTAL PERMIT FEE $ OCCUP. GROUP I TYPE OF CONST. PARCEL PD ISSUE This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PUBLIC ByW. / PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been aid. P WORKS v Date•,) — 1 7 tF-(� Yr •• �� ��+` �ig Receipt No. t� ei / WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT J=OK 0 = Nqt OK = Not Applicable * = Not Ready MOBILEHOMES i MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except #'s Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except #'s 1. Zoning Requirements—Setbacks—Easements Zoning Requirements—Setbacks—.Easements 2. Soils; Special MH Support—Sketch otings; Size—Depth—Spacing—Connectors 3. Sewer; Location—Test—Fall-C/0—Concrete a s; Gir or Jois r g—Bracing—Stairs—Rails 4. Water; Location—Test—Easement Needed (Sketch) ood Awn.; Posts— B f onnec.—Sh .—Rfg.—Bracing 5. Electricity; Location—Clearances—Grnd.—/ / Amp—Concrete 5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures 6. Gas; Location—Test—Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG 6. Carports; Windows—Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card- Date Card -BI Date Card -BI Date Card -BI Date Card -BI CXV9te — Card -BI Date Date MOBILEHOME INSTALLATION (Plans) OK except #'s Date 0 L (Plans) OK ex ept #'s 1. Zoning Requirements—Setbacks—Easements 1. Setbacks—Easements 2. Footings; Size—Spacing—Marriage Line 2. Soils; Compaction—Structure Stability 3. Gas; MH Test—Demand—Valve—Connector 3. Pool Structure; Steel—Connections—Thickness—Dead Men—Lining 4. Electricity; MH Test—Crossovers—Breakers—Clearances 5. Drain; MH Test—Fall—Flex Connector 4. Elec.; Receptacles and Lighting; Distances—GFI 5. Elec.; Pool Lighting; 15 volts—GFI 6. Water; MH Test—Regulator—Connector 6. Elec.; Enclosures; Conduit Entries—Terminals—Listed 7. Water and Sewer Connected—C/0 to Grade—HD Approval 7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghtg. Boxes—Enclosures—Panel boards—Ins. to Main in Conduit 9. Health Department Approval 9. Exits; Insp.—Sketch 10. Cert. of Occupancy 10. Plumb; Cir. Test—Water Supply Test Card B -I Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date I V = OK 0 = Not OK - = Not Applicable �E Not Ready RESIDENTIAL (Single and Duplex) Date UNDERFLOOR Plans OK except #'s _Date FRAMING (Continued) 1. Zoning requirements-Setbacks=Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50. Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 51. 52. Plywood on Roof Overhang -Attic Vents -Rafter Outriggers Siding -Nailing -Veneer 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underflr. Access 7. Piers -Fireplace Ftg.-Steel 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/0 -Sewer Test 55. Shear Walls; Nailing -Bolts 9. Gas Pipe; Size -Anchors 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground ' 12. Plenums & Ducts; Clearance -Material -Support -Ins. 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -Bl. Date Card -BI Date Card -BI Card -BI Date Date Card -BI Date Date Card -BI Date FINAL (Plans) OK except N's 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except q's 14. Water Ht.; Vent -Access -Combustion Air 57. 58. Smoke Detector Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tutt Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. 63. Stairs & Rails Fireplace or Stove; Clearances -Hearth Card -BI Date Card -BI Date 64. 65. Elec. Outlets at Wood Panel; Int. & Ext. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI Date Card -BI Date 66. Elec. Outlets & Receptacles of Kit. Counter Date ELECTRICAL Permit OK except q's 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture & Transformer Clearance -Ins. Protection 69. Wtr, Htr.; Vents -Clearance -Comb. ;Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. Elec. Receptacles Spacing -Lights &Switches at Doors 22. Size Boxes & No. of Conductors -Stapled 70. Plb., Elec. & Mech. Equip. Listed for Location 23. Romex Installed Close to Edge of Studs & C.J. 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 24. Equip. Ground made up w./Mech. Fasteners -Bond Gas & Water 72. Insulation -Foam -Looked in Attic ❑Yes 25. 2 Appliance Circuits in Kitchen & Conductor Size 73. Guard Rails & Deck Construction -Post Caps 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or Al 74. Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral ❑Yes ❑No 75. Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes ❑ No; Planters ❑Yes 0 N 28. Service -Riser Conductors & Ground -Main Disconnect 76. Stucco; Brown -Finish 29. Equip. Clearances; Panels-Motors-Mech. Equip. 77. A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. 80. Water Well; Disconnect, Electrical, Plumbing Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B -I Card B -I Date Card -BI Date Date Card -BI Date 81. 82. Ventilation throughout House Glass Protection Date MECHANICAL (Permit) OK except q's 83. 84. Corrections from Previous Inspections Gas Test -Meters Tagged; Gas -Electric 31. A.C. Ducts; Insulation & Support 85. Water & Sewer Connected -C/O to Grade -HD Approval 32. Vent Fan; Exhaust above Insulation 86. Energy Compliance Certificate -Other Certificates 33. Condensate Drain & Overflow; Size _& Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic Access & Platform if Furnace in Attic Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FRAMING(Plans) OK except k's Comments at Final: 36. Sills; Proper Material & Anchors 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound 38. Bearing Walls over Girders & Floor Nailing 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. Header & Beam -Size & Bearing 42. Hangers -Post Caps -Anchors -Connectors 43. Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shthng.-Rfn_g_. 44. Fireplace Ties or Type A Flue -Fireplace Throat 45. Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles 46. Bdrm. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. Garage Fire Protection Framing (NOTE: An entry must be made each time youvisit jobsite) OFFICE COPY Address GAS _ Meter By Date ELECT IC�� Meter B at Temp. Power ? _ Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Service Called -PG&E JOB FINALED (Date) l.Z_r���✓ " / Signature 7 • I PERMIT NO. 65-41-02 2755-82P,E (MH) z -93 PERMIT EXPIRES OWNER ILA SIMON CONTR. John Henry Const., Magalia ASSESSOR PARCEL 65-41-02 LOCATION /S060 Sack Pine, Magalia lot 27, F Unit 3, Magalia i• • ` a f F OFFICE COPY • Address Date& 5 GAS Meter BY ELECTRIC Date {� Meter By OFFICE COPY Address GAS _ Meter By Date ELECT IC�� Meter B at Temp. Power ? _ Called PG&E Temp. Elec. Service Called PG&E Temp. Gas Service Called -PG&E JOB FINALED (Date) l.Z_r���✓ " / Signature 7 �45' 'M JOK 0 = Not OK ° I = Not ReadyY� M%JDILCn%JMCJ MIO%_CLLANCVUJ Date MO I OME UTILITIES (Plans) OK except H's Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except q's ing Requirements—Setbacks—Easements 1. Zoning Requirements—Setbacks-Easements 2. S ' s; Special MH Support—Sketch _ 2. Footings; Size—Depth—Spacing—Connectors 3 r; Location—Test—Fall-C/0—Concrete 3. Decks; Girders and/or Joists—Decking—Bracing—Stairs—Rails 4. W ter; Location—Te —Easement Ne etchj 4, Wood Awn.; Posts—Beams—Rftrs.—Connec.—Shthg.—Rfg.—Bracing lectricity; Loc ion -Clearances .—/ Amp—Concrete 5. Alum. Awn.; Columns—Connections—Splice—Decal—Enclosures as; Location—Test—Wrap:/ /"L"ft./ /"Nat. or/ L" ft./ J/;It.PG 6. Carports; Windows—Doors 7 city Clearance 7. Elec. Card -BI Date and -BI Date Card -BI Date Card -81 Date Card-BI44 Date rd -BI Date Card -BI _ Date Card -BI Date Date 0 It EHOME INSTALLATION (Plans) OK except N's Date POOLS (Plans) OK except k's oning Requirements—Setbacks—Easements 1, Setbacks—Easements ootings; Size—Spacing—Marriage Line 2. Soils; Compaction—Structure Stability as; H Test—Demand—Valve—Connector 3. Pool Structure; Steel—Connections—Thickness—Dead Men—Lining ectricity; MH Test—Cr s s—Bre rs—Clearances 4. Elec.; Receptacles and Lighting; Distances—GFI Drain; MH Test—Fall—Flex Connector 5. Elec.; Pool Lighting; 15 volts—GFI Water; MH Test—Regulator—Connector 6. Elec.; Enclosures; Conduit Entries—Terminals—Listed er and Sewer Connected—C/0 to Grade—HD Approval 7. Elec.; Bonding; Metal w/5'—Circulating Equipment—Heater 8. Gas and Electricity Tagged 8. Elec.; Grounding; Equip. w/5'—Circulating Equip.—Pool Lghtg. Boxes—Enclosures—Panel boards—Ins. to Main in Conduit 9. Health Department Approval 9. Exits; Insp.—Sketch 10. Cert. of Occupancy 10. Plumb; Cir. Test—Water Supply Test Card B -I 1 Date Card -BI Date I Card -BI , Date Card -BI Date Card 8-1 Date f Card -BI Date Card -BI Date Card -BI Date 1D A r ;, -q X096 o >z OK r 0 = Not OK - = Not Applicable * = Not Ready RESIDENTIAL (Single. and Duplex) I Date UNDERFLOOR Plans OK except #'s Date FRAMING (Continued) 1. Zoning requirements -Setbacks -Easements 48. Property Line Firewall & Openings 2. Ftg., Main; Soils-Steel-Elec. Grnd.- / /" Ftg. Depth 49. Ext. Doors -One 3' -Check Garage -3rd story, 2 exits 3. Ftg., Garage; Soils -Steel- / /" Ftg. Depth 50...Stairs; Width -Headroom -Rise -Run -Landing -Fire Protection 4. Ftg., Porches & Decks; Soils -Steel- / /" Ftg. Depth 51. -Plywood on Roof Overhang -Attic Vents -Rafter Outriggers 5. Stemwalls, Main; Steel-Blockouts-Wrapped-Slab 52. Siding -Nailing -Veneer 1 6. Stemwalls, Garage; Steel-Blockouts-Wrapped-Slab 53. Stucco Mesh -Drip Screed-Fdn. Vents-Underfir. Access 7. Piers -Fireplace Ftg.-Steel ' 54. Glazing Area -Glass Protection -Skylights -Plastic 8. D.W.V.: Fall -Fittings -Test -2 way C/O -Sewer Test 55. Shear Walls; Nailing -Bolts 1 9. Gas Pipe; Size -Anchors 10. Water Pipe; Test -Anchors -Regulator -Service Test 11. Electric; Underground 12. Plenums & Ducts; Clearance -Material -Support -Ins. s 13. Girders -Sills -Anchor Bolts -Joists -Vents -Cripples Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date FINAL (Plans) OK except #'s 56. Ext. Steps -Door & Sidelight Protection -Landings Card -BI Date Date Card -BI Date PLUMBING (Permit) OK except #'s 14. Water Ht.; Vent -Access -Combustion Air 57. Smoke Detector 58. Furnace; Vents -Clearance -Comb. Air -Connector - In Garage; Above Floor-Ducts-Mech. Protection 15. Water Pipe; Test & Anchors -Nail Protection 16. D.W.V.; Test-Fttngs & Anchors -Nail Protection 59. Bedroom Exiting 17. Shower Pan; Test, First Floor -Tub Access 60. G.F.I. & Bath Fixtures & Tub Access 18. Test Tub & Shower, 2nd Floor -Tub Access 61. Elec. Trim & Subpanel; Breaker Sizes -Labels 19. Gas Pipe; Size & Anchors 62. Stairs & Rails 63. Fireplace or Stove; Clearances -Hearth 64. Elec. Outlets at Wood Panel; Int. & Ext. Card -BI Card -BI Date Card -BI Date Date Card -BI Date 65. Kit. Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance 66. Elec. Outlets & Receptacles at Kit. Counter Date ELECTRICAL Permit OK except #'s 67. Garage Fire Door; Swing -Landing -Closer 68. A.C. Duct in Garage -Damper 20. Fixture &Transformer Clearance -Ins. Protection 69. Wtr. Htr.; Vents -Clearance -Comb. Air-Connector-P.R.V.- In Garage; Above Floor-Mech. Protection 21. 22. Elec. Receptacles Spacing -Lights & Switches at Doors Size Boxes & No. of Conductors -Stapled 70. Plb., Elec. & Mech. Equip. Listed for Location 71. Elec. Receptacles in Garage; (G.F.I.)-Romex Protec. 23. Romex Installed Close to Edge of Studs & C.J. 72. Insulation -Foam -Looked in Attic E) Yes 24. 25. Equip. Ground made up w/Mech. Fasteners -Bond Gas & Water 2 Appliance Circuits in Kitchen & Conductor Size 73. 74. 75. Guard Rails & Deck Construction -Post Caps Fdn. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Looked under Floor ❑ Yes Following instld.: Drive ❑ Yes ❑ No; Walks ❑ Yes E) No; Planters ❑Yes 0 N _ 26. Subfeed Wire Size / / ga. Cu or AI-A.C. Wire Size / / ga. Cu or At 27. Range Circ. / / ga. Cu or AI -Oven Circ. / / ga. Cu or Al, Insulated Neutral ❑Yes ❑No 28. 29. Service -Riser Conductors & Ground -Main Disconnect Equip. Clearances; Panels-Motors-Mech. Equip. 76. 77• Stucco; Brown -Finish A.C. Unit; Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 30. Clothes Closet Light -Shower Light 78. Vents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. 79. Water Well; Disconnect, Electrical, Plumbing ` 80. Exterior Elec. Trim; G.F.I. Receptacle -Underground Card B-1 Date Card BI Date 81. Ventilation throughout House Card B-1 Date Card -BI Date 82. 83. Glass Protection _ Corrections from Previous Inspections Date MECHANICAL (Permit) OK except #'s 84. 85. Gas Test -Meters Tagged; Gas -Electric Water & Sewer Connected -C/O to Grade -HD Approval 31. A.C. Ducts; Insulation & Support 32. Vent Fan; Exhaust above Insulation 86. Energy Compliance Certificate -Other Certificates _ 33. Condensate Drain & Overflow; Size & Grade 34. Furnace -Vent; Access -Comb. Air -Return Air Vent -115V outlet 35. Attic'Access & Platform if Furnace in Attic - Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Comments at Final: Date FRAMING(Plans) OK except #'s 36. Sills; Proper Material & Anchors 37. Walls; Studs -Nailing, Spacing & Bracing -Plates -Sound _ 38. Bearing Walls over Girders & Floor Nailing _ 39. Draft Stop in Walls (rat proof) 40. Fire Stops; Furred Ceilings -Stairs -Chases -Tub 41. Header & Beam -Size & Bearing _ 42. 43. 44. 45. Hangers -Post Caps -Anchors -Connectors Cing. Joist-Rftr. Ties-Purlin-Roof Brac.-Truss-Shihnq.-Ring. Fireplace Ties or Type"A, Flue-Fir6place Throat Attic Access; Size & Romex Protection -Draft Stop -Ins. Baffles _ 46. Windows or Exiting Doors -Sill Hgt. & Dimensions 47. _Bdrm. Garage Fire Protection Framing (NOTE: Anentrymust be made each time youvisit jobsite) r COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 7 COUNTY CENTER DRIVE OROVILLE, CALIF. - 534-4541 CERTIFICATE OF OCCUPANCY This mobilehome has been installed in accordance with the requirements of the California Administrative Code, Title 25, Chapter 5, under permit number'7. 5&'6— for the following location: / «),,-n r, Owner ? 1 Q- ! n rk) ,• � Owner's Address %7lY gYeLll _ _ ,C GAJ T3D. T4' /Aii "D!-1 CA Mobilehome Mfg. �/���-' <TrA Model dear Insignia No., * z .y Serial No.�1 � It is hereby certified for occupancy at the above described location and may be occupied. Director of Public) Works Date 9'—/":::7- % By THIS CERTIFICATE IS VOID WHEN MOBILEHOME IS RELOCATED L. White - Owner, Yellow - Installer, Pink - D.P.W. COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS -- 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE -51#1 -Z�'V"6-- 8r OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. It you have any question pertaining to this matter, or need additional explanation, please contact this office Immediately. C Inspector — —/ Date �S �� _ COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS 7 County Center Drive - Oroville, Califorriia 95965,: Telephone 916/534-4541 APPLICATION AND PERMIT PERMIT NO 0 ASS 50 ARCEL MBER ZONING . BUILDING PERMIT ' OWNE j.m � ( I TELEPHONE S0. FT. OCC, BUILDING VAL j ATI OWNER'S MAILING DDR SS Sa C, - ACTOR• NA ELEPHONE1 crz_ n P X17- s N�TRA3CTORADDRESS A � _ Fireplace CONSTRUCTION LE D R UNKNOWN - Total Valuation $ FilingFee $ 10.00 LENDER'S MAILING AD Ess .- Permit Fee $ 1407-) ARCHITECT OR ENGINEER LICENSE NO. Plan Checking Fee $ h Penalty $ ` ARCHITECT OR ENGINEE 'S MAILING ADDRESS Permit fee $ BUILDING ADDRESS O PLUMBING PERMIT Filing Fee 10.00 `n `A Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT t•{o. ���'C/J� ISFFNYME PARCEL MAP Each qas water heater or vent 5.00 Gas piping system 1 - 5 outlets 5.00 USE OF STRUC E I dxc SF ❑ Duplex❑ Mobilehome❑ OtherI) SPECIFY Building sewer 5.00 Mobile Home S I G I W 10.00 e TYPE OF WORK New Addition[-] Remodel❑ Utilities [I Installation❑ Other E] Describe work: — Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 100 AMP OR00V OR LESS10.00 Cts tS Main service EA. ADD•L too AMP 2:50 NEW CONST. / DWELLING OCCUP.& OR ADDNS. ( ACC. BLDGS• 2I/4sq ft CONTRACTORS LICENSE LAW I declare er penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. of the Business and Prof essi d and my license is in fu I for(jZc and effect. License No. pClassification J ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) % ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEWC CONSTR ULTI.OUTLET 2.50 ea NON.RESID BRANCH CIRCUITS) NEW CONSTR.POWER APPARATUS & NON.RESID. (SINGLE OUTLET CIR. 20050a Ex. Occup(ouTLETs OR FIXTURES BAL®30 FIXED APPLNS. OR Ex. Occup. OUTLETS (RESID,) EAJ 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑T permit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: if after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT Filing Fee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot utte to enter upon the above-mentioned property for inspection purposes. I a ree to save, ind minify and keep harmless the County of Butte against all liabI ' ies, judgments, costs, and expenses which may in any way accrue against sai County in con equence of Re granting of this per it. FU1 !�J Date ignartrre IApp icanr - Owner Contractor ❑ Agent ❑ A OSHA per ' is required for excavations over 5'0" deep and demolition or construct- ion o t: c over 3 stories in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ Q b� OCCUP. GROUP TYPE OF CONST. JPARCrLJ PD X111SU This permit is hereby issued under sions of the'•Butte County Code and/or work indicated above for - which DIRE O OF PUBLIC By P IT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date '' 27� �� Z�- �S- �-y Receipt No.� �fl (rJ �7 WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT Z 4-0 setback of .5 ft. from the ro perty lines and a setback Irof 50ft. from the road 'centerline shall be Clear of structures ore ui 9 for a 2 ft. eave overhanq, 4 A pi L T..'s L ID'rL MIS sei of plans crng specifications MUST Fe kept on the job at 011 tunes and it is unlawful to moo nny changes cr rAr1r--,;+ior.s on same without --wiffen-per ;nN4 Works, County of BI. WME: DATE -- --- - -. _. .- rte_ - •-• _ ; • `-_:_ . ' ' _; .__. _ r AF hUV. 0, `� _LL O .� -� < O CD _ v _w.a-. -a.CDCD � -: n -a; -► I --row _•.. �. S 0. D. /1 ti 7 CD �ltOTE:—All Material's & Workmanship_ Shall Be ir, Ln 4 Accordbnce v✓ A,- Recogni=.e,dj Good Practices and x I- of a Cunlity rr?scriha d le, A.- --- - -. _. .- rte_ - •-• _ ; • `-_:_ . ' ' _; .__. _ r AF hUV. 0, `� BUTTE OOUNTy DEPAipgff :OF PUBLIC WORKS 7 County Center Drive, Oroville, CA._ PHONE: 534-4541 MOBILEHOME INSTALLATION SHEET - - IL. tOvnei's nsmei_�', R CO CEPTSP INCL ,2. ,Installer's na®e: A "33 SKYWAY ' -PARADISE, 4A. 959b9 S. - Zs the site currently unde#qWFhXQ'?6) 87711�._ NO (If, yes,.. furnish -permit number ~ia the site an existing site? Yes -NO ' f (If yea, furnish two (2) plot plans.) . 4. Will the mobilehome be located at least 5 ft, array f septic tank and leach fields and clear of all setbacks and easements? Yes / No (If no, clarify ' 5. What is the mobilehome electrical rating... ---------- y Amps g 6. What is 'the -mobilehome site service rating? --------------------- o)•yD Amps 7. What is the mobilehome site circuit breaker rating? ---------/ Oy Amps 8. Is there any other electric load to be served by the mobilehome site service? ------------------------------------------------- Yes No -- (,If yes, identify the load and size: (Load) _ (Amps) 9. What is the mobilehome site gas pipe size? ------------ ---------- _��� (in L ----------------------------- 10. What is the type of gas service? Natural ^% 11. What is the gas pipe length from meter or tank to the mobilehome? 12. What is the mobilehome gas demand? ------------------------------ information not required if pipe length less than 6 ft. on natural gas or less than 50 ft. on LPG.) (ft') E WNW- - TA/,5 P) CGq 7 � IRUTTE �OUt'4TY BUILDING DEPARTMENT APPROVED �iidth�_�_(ft.) Box Length, _(ft.) Tagalong or Expando Size �ft. ft. (SRo(i SUPPORT DETAILS BELa00 On all mobilehomes manufactured after October, 7. 1973, furnish manufacturer's installation nanual and structural setup sheets (if not on file with the County of Butte). _ll center supports measured from front of ' -a-obilehome unless otherwise specified. 09Js (check one) T4; ID) D AAJUG000 - Singly r©t .:a. 1. mood either n \ - -:.-, �. ,t.' ressure treated c LTJ (ft. (inz) .ter s port '_ocati s* r l (ft. in. . K VVx 30 x� tenter piers are other than drawn above, in locations, spacing, and dimensions. ., ;;: ,, _ p•fti,;.;:; foundation grade. [] 2. Other: (specify) (check one) PV . Concrete block. -2. Other. (specify) Tagalong or Expando,' show support details. -- Typical Support in.) Footing Size (ft.)(in.) -- Max. Pier Spacing -- Max. Overhang I" C ,y.g. a STH 4wt-M, M-? oN :�b I?,v' �d�Jp ootoENwit -IWO. b-"ILY So. FT. MOBILE fomis , mo moo}.{$ ,� � "04" o::io"a SUPPORT PIERS ''OD" NO CAPACITY FOOTING SIZE 1 0 1 CAPACITY I FOOTIN 20009 12"X 24—8-0-0--o-1---48x 4000 41'x24" 10,000# 60 x ® 600b# 36 x24 ftl�� FOR FIELD SUPPORT DETAILS. SEH OWG'S. S-1 and S-1 OF INSTAI I ♦rims uAuuAi 70 LNt►�IGr M,b1Nt►J6'r,H".L,rAMILY�t-'1, �G1h16�,!e'rvN �d�Jp ootoENwit -IWO. b-"ILY So. FT. MOBILE fomis , ,� � "04" o::io"a CARPET LAYOUT AND RIDGE ''OD" NO .w�ufaww u"„ain�ns BEAM FIELD SUPPORT PIERS'' 701Aw"Ir T.x/,� �%•/IQj'OI2 onwo "o aEvuro •r T. w.1 11 if i Le /-+AA-Q COUNTY OF BUTTE - DEPARTMENT ON PUBLIC WORKS„ PERMIT NO.;. 7 County Center Drive - Oroville, California 959$5 - ffelephone 916/534-4541 APPLICATIOWAND PERMIT ASSESSOR PARCEL N MBER — — ZONING t BUILDING PERMIT TELEPHONE SO. FT. OCC. BUILDING V ATION OWNER'S M G ADDRES �� Nos- s . ' O TRACTOR'S NAM TT..11 TE EPHONE V tel/ , ACTO 'S M (LING ADDRES ^� 33 (`n7 Fireplace CONSTRUCTION ENDER UNKNOWN Total Valuation $ Filing Fee- $ 10.00 LENDER'S MAILING A D Ess _ Permit Fee $ ARCHITECT OR ENGINES - LICENSE NO. Plan Checking Fee ,$ Penalty $ ARCHITECT OR ENGINE R'S MAILING ADDRESS Permit fee $ BUILDING ADDR SS PLUMBING PERMIT Filing Fee 10.00 CA Each Trap 2.00 Solar Water Heater 20.00 Water piping 5.00 LOT NO. SUBDIVISION NAME PARCEL MAP ,917 oeGas Each gas water heater or vent 5.00 piping system 1 - 5 outlets 5.00 USE OF UCTURE SF [:1 Duplex[] Mobilehome OthOther SPECIFY Building sewer 5.00 Mobile Home S G W 10.00 e TYPE OF WORK New ❑ Addition ❑ Remodel ❑ Utilities ❑ Instal latiorj:zOther ❑ Describe work: --7^ l Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 10ov OR LESS 100 AMP OR LESS 10.00 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. DWELLING OCCUP.&` OR AODNS. ACC. BLDGS. / 21/20sgft CONTRACTORS LICENSE LAW I declare penalty of perjury (Check one): I am licensed under provisions of Chapt. 9, Div. 3 of the BUSIneSS and Profes de nd my license is in ful force d effect. License Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ 1, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ 1 am exempt under Sec. , Business and Professions Code for this reason N0N-Resin R BRANCH CIRCUITS 2.50 ea NEW CONSTR. (POWER APPARATUS & NON.RESID. l SINGLE OUTLET CIR. ) 50 EX. OCCUp(OUTLETS OR FIXTURES AO FIXED APPLNS. OR EX. OCCUp. OUTLETS (RESID.) EA.� 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. Wiring 15.00 Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): n Zgifpermit is for $100.00 (valuation) or less. I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIIng Fee 10.00 Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 o agree to sa indemnify and keep harmless the County of Butte against all Ii ilities, 'udg ents, costs nd expenses which may in any way accrue of the granting of this permit. agains . aid Co nt i conseqVThis Date Signat of Applicant — r ❑ Contractor ❑ Agent ❑ An OSH permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over in height. Mobile Home Installation Fee $ TOTAL PERMIT FEE $ "� OCCUP. GROUP TYPE OF CONST, PARCEL PD ND ISSUE permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIREC R OF PUBLIC BY PER(dT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date or337stories Receipt No. WHITE-D.P.W., YELLOW-ASSFSSOR. PINK -INSPECTOR, GOLDENROD -APPLICANT Return to DPW 92 AGRICULTURAL STATEMENT OF ACKNOWLEDGEMENT _ - --2891 I FOR RESIDENTIAL DEVELOPMENT ' 0�{d1A, ciE,:ti4tc Section 26-8.1of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents of CCRi/'� this property may be subject to inconveniences or discomfort arising CL'ERK'R=CUNEk FEE from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited -to cultivation, plowing, spraying, pruning, and harvesting which occa- sionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: C LOT 2% as shown on that certain Hap entitled "PAR01SE PINES UNIT NO. 3* which was recorded in "the office of the County Recorder of Butte Count? on June-17-9-1970_.in_.Map Book -31 -at -_pages -78; Subject to Covenants conditions, restrictions, reservations, rights of way, easements, bonded i;Aebtedness, assessments, and other matters of record. EXCEPTING all minerals, as excepted of record. Date: PROPERTY OWNERS: State of �o�.A/iA ) On this the � day of,:P , 19 , SS, before me, the undersigned Notary'Public, personally County of �,,i z'"iVeliea ) appeared Ila Irene Simons known to me to be the person(s) whose name(s) ,o. OFFICIAL SEAL subscribed to the within instrument and acknowledged BARBARA SO€ ERG A that� S,�,g executed the same for t e purposes NOTARY PUBLIC • CALIFORNIA � p p therein contained, 4. �n s `v" GTY AtoJ .�UFIIV OF SAN F8ANGSICU IN WITNESS WHEREOF I hereunto set my hand and official r �.,."� Py My Comm. Expires Dec. 26, 1985 � seal. J L Nota c Present A.P. NO. END OF DOCUMENT • �i iy3 S;�e bA�♦ il. _Tla Simons John Henry Construction 7 1701 Shoreline Drive, .apt. 20 P.O. Box 509 Alameda. Ca. 94501 Magalia, Ca. 95954 t (916) 873-0668 Unit 3, Lot 27, Magalia, Ca. 95954 i DOTE:—All Materials & Workmanship Shall Be in ti TiAccordance with Recognized Good Practices and Of a quality prescribed for •rhe Specified use in the Uniform Building, Plumbing & Machanical Codes and the National Electrical Code. } Mir Utillty, nnections shall be within . . , 4 ft, ® the mobilehome, either '`''permit 'r be •req re" TorfFie dirocih,r bohind or within the rear nstallaf of them bill homer- half of the roadside (left) of the�- mobi ehome. S00 SO. FT. MINIMUM EOR MOBILES ` r C i I J4, 4 6T rF �. s eCITI 14n$ IV US : bU C�/Q Isle 6�p fans and p icy it is unlawful to an the to qt al{ tim a+ion on same without 'n e�kn any changes,or alter b{ic arf'ment of Pau t- from the De r rotten permission ••r v ti s . orkS, COU Ty .� —A-seebe rom the` ` yx P p ty lines and a setback of'50ft. from the road �ccenterline shall be clear of � structures or � ctur equipment excepy - y�� ✓Z� _��i- z� r� for a 2 ft. eave overh �x t DATE: # `. BUTTE COUNTY ' h 1 ;l BUILDING DEPARTMENT �I } , APPROVED COUNTY OF BUTTE - DEPARTMENT OF PUBLIC WORKS PERMIT NO. •j 7 County Center Drive - Oroville, California 95,965 - Telephone 916/534-4541 r APPLICATIONIND''PERMIT / ASSESSOR PARCEL NUMBER . -- _ 6 Z- ZONI BUI ING PERMIT OWNER Ila Simon TELEF1HbNt S0. FT. I OC BUILDING VALUATION OWNER'S MAILING ADDRESS CONTRACTOR'S NAMET John Henry Construction LEPHO X73-O��i8 CONTRACTOR'S MAILING ADDRESS P.O. Box 509, Magalia, Ca. 95954 Fireplace CONSTRUCTION LENDER E UNKNOWN Total Valuation $ Filing Fee $ LENDER'S MAILING ADDRESS Permit Fee ' $ ARCHITECT OR ENGINEER LICENSE NO.. Plan Checking Fee $ Penalty $ ARCHITECT OR ENGINEER'S MAILING ADDRESS Permit fee $ BUILOI G ADDRE IsnIM L c PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 Repair drainage or vent piping 5.00 Water piping LOT NO. 2 SUBDIVISION NAME Unit 3, Ma alfa PARCEL MAP Each qas water heater or vent 5,00 Gas piping system 1 - 5 outlets USE OF STRUCTURE SF ❑ Duplex[] Mobilehomef] Other SPECIFY Building sewer Lawn sprinkler system 5.00 TYPE OFWOR New ® Addition ❑ Remodel ❑ Utilities Installation❑ Other ❑ Describe work: site preparation or mobilehome utilities Permit Fee $ 4Z2 6,c - Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service 6101 OR LESS 100 AMP OR LESS 5 Main service EA. ADD'L 100 AMP 2.50 NEW CONST. /DWELLING OCCUP.EI) OR ADON.S, `ACC. BLDGS. 2�sgft CONTRACTORS LICENSE LAW I declare der penalty of perjury (check one): I am licensed under provisions of Chapt. 9, Div. 3 of the Business and Professions C de and my license is in full force and effect. 349997 A License No: Classification ❑ I, as the owner, or my employees with wages as their sole compen- sation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ I, as the owner, am exclusively contracting with licensed contract- ors. (Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONSTP NON•RESID BRANCH CIRCUITS 2.50 ea NEW CONSTR. ( POWER APPARATUS 61 NON•RESID. SINGLE OUTLET CIR. Ex. OCCUp OUTLETS OR FIXTURES BAL�1 BAL@c Ex. 0ccup.(OUTLETSIXED P(RESID )LISIS REA. 2.00 Temporary service 10.00 Mobile Home Facilities •15.00 OU Misc. Wiring 7.50 Permit Fee $ 3 2S Contractor MECHANICAL PERMIT FiIirig Fee 10.00 WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. ® I have placed on file with the County of Butte Building Department a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. Heating Cooling Hood 3.00 Ventilation permit Fee $ Contractor 1 certify that I have read this application and state that the above information is correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the County of Butte to enter upon the above-mentioned property for inspection purposes. I also agree to save, indemnify and keep harmless the County of Butte against all liab' ies, judgm costs d expenses which may in any way accrue again d Count n onse n of the granting of this permit. q X p Date / _Z1/. Signature of Applicant — Owner ❑ Contractor ® Agent ❑ An OSHA permit is required for excavations over 5'0" deep and demolition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ _0 TOTAL PERMIT FEE $ occuP. GROUP I TYPE OF CONST. I PA7 Pb HD Iss1 This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which D! CTOR F PUBLIC By PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date Z� y Receipt No. WHITE-D.P.W., YELLOW -ASSESSOR, PINK -INSPECTOR, GOLDENROD -APPLICANT Return to DPW AGRICULTURAL STATOONY' OF ACKNOWLEDGEMENT FOR RESIDENTIAL DEVELOPMENT Section 26-8.1 of the Butte County Code requires this acknowledgement be recorded prior to issuance of a building permit. q2-28�1� The property described herein is adjacent to land or included within an area zoned for agricultural purposes, and residents ofp�QR R. 0! this property may be subject to inconveniences or discomfort arising CL -RECUIiQEFc FSE from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting-which*occa- sionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and on adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California described as follows: , as shown on that certain Map entitled "PARADISE PINES UNIT NO- 3" ethic was recorded in 'the office of the County Recorder of Butte County on June 179 1970 in Map Book 35 at pages 78, 79, 809 81 and 82. Subject to Covenants conditions, restrictionsreservations, rights of way, easements, bonded inJebtedness, assessments, and other matters of record. HXCEPTIN0 all minerals, as excepted of record, Date: �� /� �,Z PROPERTY OWNERS: State of�,4,(i�oeiV,;g ) On this the day of 19 19 '.Z , SS. before me, the undersigned Notary'Public, personally County of rN /,eANC,Esc•a) appeared Ila Irene Simons _ known to me to be the �— _ person(s) whose name(s �OFFICIAL.:�T.''.�:?_, subscribed to the within > w instrument and acknowledged �.i;,". t;(., '•`..�; that s�tf.� executed the rp ? `•'l r.OTA- -,r !��. c : U;.! :'r—UH. YA, in containedxec same for the purposes there Cl�;l;r;c(r,(Q IN WITNESS WHEREOF, hereunto set my hand and official f.'.� Con.ri. !:xpu s Dec.Ucc2G, 14c35 r �.��f•�_�,-.�, seal. ..1. �J 4 - 1/2" MB TYP. 4 - 1/2" ADJUSTING NUTS - TYP. 1 1/2" X 3" PIN OR 1/2" GR.5 MACHINE BOLT 6 NUT 1 r 4 - 3/8" MB TYP. RP2029 PAD WITH RP2000 SERIES STAND NO SCALE 4 - 1/2" MB TYP. 4 - 1/2" ADJUSTING NUTS - TYP. 1/2" X 3" PIN OR 1/2" GR. 5 MACH I NE BOLT & NUT 4 - 3/8" MB TYP. RP2028 PAD W I TFf` RP1.900 SERIES STAND NO SCALE 0 0 CE—i� 314 O 1 NG 0 v16+ 0 1/2--� 36 V2" I' RP2029/202SB PADS NO SCALE 36" 1-1/2" TYP 1-1/2" TVP - 36" SIDE VIEW RP2028 PAD NO SCALE END VIEW 57/" IV20pipe -Sch40 ' i 2 `` 17/8' O Q O O O O O N O O N N B Extension A Extension FOR RP2013/2021 STANDS FOR RP2007 STAND c �. 4 - 9/16' 0 n 2 - V4'0 .3* >� r* 0 3/4- 8 0o sidY) o � Yo 0 N o 0 0 0 n -� �O 3/4- 2 1/2-- �- } 7!� 19/16 0 s 4 04' bQ stock Til _V2 Oreoded rod Q-Regd) �l 9/16 0 Beam Restraint -Clamp . DESIGN LISTED AND TESTED BY BSK A ASSOCIATES I WAYNE T. POLVADO, PE - LISTING NO. F01601053 QRDf ESSIO// C 51st; ; ltc OjC nntJEitJ[i.>� +C7t J.vi1♦11Ur+ AEA N AND SAFETY COOL. SECTIOPA 18337 A P P R O V E D SUBJECT r0 CORRECTIONS NOTED Approvol does not authorize or approve a.:1 orrnsmon o, dewiv"m 40r" reQUire,neriq of am4' b,: S::•e tc_: m. G reguk.Tem !.. e..:: Department of liouvng en.; '_ .mmuniiy J!.ciopm&" (740 Date Z_ t+iPrerura) LP C - chowl (Joist) SPA NO. 1 : t CAST -IN-PLACE FERROL INSERTS 2 V2' 2 V2' L 2 V2 " x 2 V2' L RFC - Q+orrrel LJoist) FOR 3/8" CADMIUM -PLATED MB - 4 EA - TYPE-_ _O a r �I o o TOP VIEW - 36" SIDE VIEW RP2028 PAD NO SCALE END VIEW 57/" IV20pipe -Sch40 ' i 2 `` 17/8' O Q O O O O O N O O N N B Extension A Extension FOR RP2013/2021 STANDS FOR RP2007 STAND c �. 4 - 9/16' 0 n 2 - V4'0 .3* >� r* 0 3/4- 8 0o sidY) o � Yo 0 N o 0 0 0 n -� �O 3/4- 2 1/2-- �- } 7!� 19/16 0 s 4 04' bQ stock Til _V2 Oreoded rod Q-Regd) �l 9/16 0 Beam Restraint -Clamp . DESIGN LISTED AND TESTED BY BSK A ASSOCIATES I WAYNE T. POLVADO, PE - LISTING NO. F01601053 QRDf ESSIO// C 51st; ; ltc OjC nntJEitJ[i.>� +C7t J.vi1♦11Ur+ AEA N AND SAFETY COOL. SECTIOPA 18337 A P P R O V E D SUBJECT r0 CORRECTIONS NOTED Approvol does not authorize or approve a.:1 orrnsmon o, dewiv"m 40r" reQUire,neriq of am4' b,: S::•e tc_: m. G reguk.Tem !.. e..:: Department of liouvng en.; '_ .mmuniiy J!.ciopm&" (740 Date Z_ t+iPrerura) LP C - chowl (Joist) SPA NO. 1 : t 2 V2' 2 V2' L 2 V2 " x 2 V2' L RFC - Q+orrrel LJoist) 'Mis Plan Ap txovai Expku U4- 2-1f-Zoo0 ro CL req d) t 3/8" a 3- bar stock 9/16 0 f2 req' 9/16 0 f2 req' 0 V2" a 3/4- ■ 6 ' (lot st. bor Alt. Beam Restraint - Clamp Alt. Beam Restraint - Clamp LO' FE 0 0 3 0 0 2' 0 SIL P,. - Sch 80 0 g . 0 0 0 0 3/16- SI. Rote �{ 0 3/4' . 3 V4' l< O a o N 2 9/16 0 N O O O RP2007 STAND RP2013'STANp ( HT 12" - 19" )• ( HT 18" 30" ) tib -3 0 0 - 2' 0 SIL Pipe - Sch 80 4 3/16 St. Place \-4*- 9/16 Or N 0 1T USE RP20298 PAD `f (SEE NOTE 15) e Q — � O N RP2021 STAND ( HT 25" - 37" ) PERMANENT FOUNDATION SYSTEM , B D S POLYMER 2000 SYSTEM S RP1900 SER 1 ES STANDSA RP2000. SER I ES STAN`D- RP2028,- RP2029 AND R �O�B® POLYMER CONCRETEG�i WILLIAM A. SOMMERMEYE ,�tSi h�OENNEER 1173-D EL CAMINO REAL - ARROYO , CA 20-2554 RCE 11658 exp.12/31/00 8j 489-5380 APRIL 1998 � 1 OF 3 SHEETS 11 ATTACH SECURELY TO 9/16" 0 CENTERED 3i MOB 1 LE HOME SUPPORT 4 `� ON PLATE 1, r'' " 'k GIRDER - TYP a I a 1-1/4 9/16" 0 HOLE pG�lip \GJ� (�O � Qhp I o FOR 1/2" MB T. P�JQQOR �� G I O? 2-.1/2" X 2-1/2"1/41' " X 1/4PLATE V ' PLATE 0� �''' 9/16" DIA. TYP. GUSSET PLATES FOR 1900 SERIES STANDS �` WISH A.'•��, '`� 1/4" ROD X 4-1/2" NO SCALE EL P�Zn GR•5 0,}=� MIN., WELDED (BOTH ARE ACCEPTABLE) to x 3a SS E OR 4, 1/2K1NG KE`Ij AND Nuj. BEAM RESTRAINT LON1NE 60L CLAMP DETAIL- NO ETAILNO SCALE 9/16" DIA. TYP.-) J� 61110" a pLpZE / AVL ID 1 WELO 1/2" MB-TYP. "-' 1I o 2-1/4" .� � y N\ -,L P . .,w 9/16" DIA. TYP.'' O BEAM RESTRAIN 1" TYP. BASE PLATE DETA I L 1/4" PLATE NO SCALE TYPICAL INSTALLATION DETAIL BASE PLATE DETAIL NO SCALE NO SCALE 1-9/16" ROD WELDED TO GRIPPER BASE PLATE. 1/2" FILLET BELOW OR PLUG WELD ABOVE ---` 1-3/4" X 1-1/16" X 1/8" PL� FORMED TO "U" 1/4" FILLET, BOTH SIDES o on on J J Q co 0 SUPPORT GIRDER BEAM RESTRAINT CLAMP, SEE DETAIL 1/2" MB TYP r2" --1/2" X 2" MB TYP. BEAM RESTRAINT BASE PLATE - SEE DETAIL 1/2" X 5" THREADED ROD. 1/4" FILLET WELD BELOW OR PLUG WELD ABOVE TO BASE PLATE O.D. SCH 40 PIPE WITH 1/2" HOLE 1/2" HOLE FOR LOCKING PIN - TYP O.D. SCH 80 PIPE -+— 3" 4 -3/8" CADMIUM - PLATED GR.5 MB TYP., L' INTO CAST -IN-PLACE I J,(? FERROL INSERTS 1„ STANDARD BEAM RESTRAINT ASSEMBLY 2-1/211t JX A 9/16" 0 -CENTERED //�J1I 3" COLLAPSED L, // 9" STD. MAX. �/ 2" X 2-1/2" X 1/4" PLATE: 13"'TALL MAX. 1/4" WELD TO BEAM RESTRAINT PLATE, BOTH SIDES OPTIONAL DIAGONAL BRACING / 1"Xill X1/8" LENGTH VARIES, 6"-42" 8" STD. 12" TALL 21" XTALL 1/2" MB CONNECTION -TYP. �. DESIGN LISTED AND TESTED BY BSK & ASSOCIATES WAYNE T."POLVADO, PE - LISTING NO. F01601053 QRCFE'SSC.lp�y �- A' :rn w ISO. V vJli.'J �mu Exp. Qn 1-u Im `ray clw- c,1�Q`/ TF C ►�L\� 14EAlrN, AND SAPPIY CODE. SECTION 1853t A PP R O Y E O SU8/EC7 7Q CORRECUCINS P40TED approvW does nol ovl4:orize or=pprore or., umi:v:or o• deviotio. vrwn eewii.e.wew« of opp:icoSie Stele lo"s .FC •eilukXi:»ti . SrT.e ci Ct:b!tvvv:. '8epnm ve vl of Mousing and Co ..mur.;ty Nvek irnerd DMISION ^.: COD't3 AND ST,,ND;.RC)S c, ------- L-- I f Dote tSPA NO. q (0 �'�an A� �irov�ol Expires �� � - 20pC� //_ z�?ROFE-;3--110 PERMANENT FOUNDATION SYSTEM BOB POLYMER. 2000 SYSTEMS RPI 900 SERIES STANDS RP2000 SERIES STANDS RP2028 , RP2029 AND RP2029B POLYMER CONCRETE PADS I WILLIAM A. SOMMERMEYER, CIVIL ENGINEER 1173-D EL CAMINO REAL - ARROYO GRANDE, CA 93420-2554 SIDE VIEW FRONT VIEW RCE 11658 exp.12/31/00 805/489-5380 RP2028 PAD WITH RP1 SOO SER I ES STAND APRIL 1998 SHEET 2 OF 3 SHEETS NO SCALE GENERAL NOTES 1. DESIGN LOADS: WIND LOAD, 80 MPH EXPOSURE "C" SEISMIC ZONE, 4 SNOW LOAD AS REQUIRED BY BUILDING OFFICIAL. 2. THIS FOUNDATION SYSTEM IS DESIGNED TO BE CONSTRUCTED ON AN APPROXIMATELY LEVEL SITE. 3. CARRY ALL FOOTINGS DOWN TO FIRM, UNDISTURBED SOIL. FOOTINGS ARE DESIGNED FOR 1000 psi ALLOWABLE SOIL PRESSURE. 4. CHASSIS BEAM SUPPORTS SHALL BE LOCATED AND SIZED FOR THE LOADS AS SHOWN IN THE MOBILEHOME MANUFACTURER'S INSTALLATION INSTRUCTIONS. S. IN AREAS WHERE DIFFERENTIAL SETTLEMENT (D.S.) CAN OCCUR, MANU- FACTURED HOME SHALL BE READJUSTED WHEN D.S. EXCEEDS 1/4", OR WHEN IT WILL ADVERSELY AFFECT MANUFACTURED HOME UNIT. 6. STRUCTURAL STEEL: FABRICATE ACCORDING TO AISC SPECIFICATIONS. WELD ACCORDING TO AWS SPECIFICATIONS. ELECTRODES, 370 PLATES, ASTM A36 BOLTS, SAE GR.5 = ASTM A449 = ASTM A372S 7. ALL EXPOSED STEEL SURFACES OF COMPONENT PARTS TO BE FINISHED IN DURABLE INDUSTRIAL -GRADE PAINT, OR CORROSION -RESISTANT PLATING, BEFORE DELIVERY TO THE MOBILEHOME SITE. NO STEEL SURFACES TO BE IN DIRECT CONTACT WITH SOIL SUBGRADES. 8. THE STAND AND PAD ASSEMBLIES SHALL BE LISTED AND LABELED BY - BSK E ASSOCIATES FOR THE FOLLOWING LOADS: HORIZONTAL 1075#, VERTICAL 5970#. 9. THESE STAND AND PAD UNITS ARE DESIGNED TO BE USED WITH MOBILE - HOME CHASSIS BEAMS OF STANDARD SECTION EQUAL TO OR GREATER THAN W8X10#. ANY OTHER SECTIONS SHALL BE FIELD ENGINEERED TO ADAPT TO SECTIONS ACTUALLY ENCOUNTERED. - 10. EXISTING COACHES MAY BE RETROFITTED TO RESIST SEISMIC FORCES BY INSTALLING THESE UNITS AS SHOWN ON THE TYPICAL FOUNDATION PLAN. 11. MULTIPLE -UNIT INSTALLATION IS ACCEPTABLE PROVIDED THE NUMBER OF FOUNDATION UNITS MEETS THE REQUIREMENTS SHOWN ON THIS SHEET AND THE PLACEMENT AND INSTALLATION PROCEDURES ARE FOLLOWED PROPERLY. 12. . FOR LONG DURATION SNOW LOADS, USE APPROPRIATE NUMBER OF ADDITIONAL UNITS AS DETERMINED BY THE FOLLOWING FORMULA: I ( LONG TERM SNOW LOAD #/FTz) X ( ROOF AREA SQ. FT.)) = 5970. USE EVEN NUMBER OF UNITS ARRANGED 50% EACH DIRECTION. (NOTE: DESIGN SNOW LOAD CAN BE REDUCED UP TO 75% WHEN APPROVED BY BUILDING OFFICIAL.) 13. FOR POLYMER CONCRETE PADS, USE CONCRETE MATERIAL CONSISTING OF SAND AGGREGATE BOUND TOGETHER WITH POLYESTER RESIN AND REINFORCED WITH CONTINUOUS WOVEN GLASS STRANDS. THE CONCRETE THUS PRODUCED MUST HAVE THE FOLLOWING MINIMUM MECHANICAL PROPERTIES: COMPRESSIVE STRENGTH 20,300 psi TENSILE STRENGTH 9,000 psi FLEXURAL MODULUS 5.8 X 104 psi TENSILE MODULUS 5.9 X IQs psi 14. THE MANUFACTURER MUST CERTIFY THAT THE MATERIALS HAVE BEEN TESTED TO THE REQUIREMENTS OF ASTM METHOD D-543, SECTION 7, PROCEDURE 1. SAID CERTIFICATION WILL GUARANTEE THAT THE CON-. CRETE HAS CHEMICAL RESISTANCE AGAINST THE FOLLOWING CHEMICALS IN THE CONCENTRATIONS NOTED: SODIUM CHLORIDE 5% SULFURIC ACID OAN SODIUM SULFATE DAN HYDROCHLORIC ACID 0.2N SODIUM HYDROXIDE 0.1N ACETIC ACID 5% KEROSENE PER ASTM D-543 TRANSFORMER OIL PER ASTM D-543 15. IN LIEU OF RP2029B PAD THE RP2021 STAND CAN BE INSTALLED USING RP2029 PAD AND APPROPRIATE DIAGONAL BRACING PER SHEET 2. RECOMMENDED PLAN' FOR 12 SUPPORTS •nn,CJ - sv'-//' JEE FABLE •---- -�' �� NOM. I 18' NOM. IALSLC BEAM SUPPORT AS REQUIRED BY MANUFACTURER-TYP. E S STANDARD MH FOUNDATION PIERS -AS RECOMMENDED BY THE MANUFACTURER OR THE ENGINEER - TYPICAL THROUGHOUT. RELOCATE AS NECESSARY- TYP. S E O O I PADS IN ANY PAIR BE ROTATED AVOID CLEARANCE _ - 2' NOM. ,l J 00"r*of Hovsinp art; Ccrvevniry D..ewumerh PROBLEMS 8' NOM. 16 O'V'S'ON or CODES AND STANDARDS 26' TO 34' 8 Sy (� RIDGE BEAM SUPPORT AS 35-54' -� REQUIRED BY MANUFACTURER-TYP.�J 55-73' ANDARD MH FOUNDATION PIERS - AS RECOMMENDED SPA NO- ------ 28' THE MANUFACTURER OR THE ENGINEER - TYPICAL ROUGHOUT. RELOCATE AS NECESSARY - (BY TYP. 12 O PADS IN ANY PAIR MAY BE ROTATED - 090* TO AVOID CLEARANCE PROBLEMS RECOMMENDED PLAN' FOR 12 SUPPORTS •nn,CJ - sv'-//' JEE FABLE •---- -�' �� NOM. I 18' NOM. RECOMMENDED PLAN FOR 16 SUPPORTS ! TYPICAL PERMANENT FOUNDATION PLANS NO SCALE E = 2' MIN / 6' MAX S = 6' MIN / 26' MAX C. NORMAL LOADS SNOW LOAD = 0 NO. OF WIDTH LENGTH UNITS 10' TO 37' 4 1 38-58' 6 10' 59-78' 8 12' TO 32' 4 33-50' 6 51-68' 8 12' 69-85' 10 13' TO 30' 4 I 31-47' 6 48-64' 8 13 65-80' 10 14' TO 28' 4 29-44' 6 45-60' 8 14' 61-76' 10 20' TO 32' 6 DESICN LISTED AND TESTED oY 8SK 6 ASSOCIATES ;; WAYNE T. POLVADO, PE - LISTING NO. F01601053 Z t'T1 Ncb. C C 11 .0 &I C r1E-1C \__ _ ..�uMtia-R�w/it tOCfw'V11IX]w •1'Ov.. rMAtDi AND SART CON. SECTK)". 18MI A PP R O VE Q SUBJECT rO CORRECFFONS ►TOTED I RIDGE BEAM SUPPORT AS REQUIRED BY MANUFACTURER-TYP. ♦PprovW does ^of ou*crue o• or>prove yy ort iss o.• a,w:ar6o ;rom rer"reate" of appficaWe Score kv i and �eavl7iMs 20' STANDARD MH FOUNDATION PIERS -AS RECOMMENDED BY THE MANUFACTURER OR THE ENGINEER - TYPICAL THROUGHOUT. RELOCATE AS NECESSARY- TYP. 16 O O O PADS IN ANY PAIR BE ROTATED AVOID CLEARANCE MAY Too TO 37' 8 00"r*of Hovsinp art; Ccrvevniry D..ewumerh PROBLEMS 618-70' RECOMMENDED PLAN FOR 16 SUPPORTS ! TYPICAL PERMANENT FOUNDATION PLANS NO SCALE E = 2' MIN / 6' MAX S = 6' MIN / 26' MAX C. NORMAL LOADS SNOW LOAD = 0 NO. OF WIDTH LENGTH UNITS 10' TO 37' 4 1 38-58' 6 10' 59-78' 8 12' TO 32' 4 33-50' 6 51-68' 8 12' 69-85' 10 13' TO 30' 4 I 31-47' 6 48-64' 8 13 65-80' 10 14' TO 28' 4 29-44' 6 45-60' 8 14' 61-76' 10 20' TO 32' 6 DESICN LISTED AND TESTED oY 8SK 6 ASSOCIATES ;; WAYNE T. POLVADO, PE - LISTING NO. F01601053 Z t'T1 Ncb. C C 11 .0 &I C r1E-1C \__ _ ..�uMtia-R�w/it tOCfw'V11IX]w •1'Ov.. rMAtDi AND SART CON. SECTK)". 18MI A PP R O VE Q SUBJECT rO CORRECFFONS ►TOTED I 33-44' 45-68' 8 12 ♦PprovW does ^of ou*crue o• or>prove yy ort iss o.• a,w:ar6o ;rom rer"reate" of appficaWe Score kv i and �eavl7iMs 20' 69-80' 16 Scare of Cvnforrv� 24' TO 37' 8 00"r*of Hovsinp art; Ccrvevniry D..ewumerh 24' 618-70' 16 O'V'S'ON or CODES AND STANDARDS 26' TO 34' 8 Sy Dote 35-54' 12 ------ _-- 26' 55-73' 16 SPA NO- ------ 28' TO 32' 833-50' I 51-68' 12 Thrt Plan Ap f1rovaj E7N1r'= C4 �' Zoo' 16 t 28' 69-77' 18 PRUFFsoze; PERMANENT FOUNDATION SYSTEM B D B POLYMER 2000 SYSTEM S RP1900 SERIES STANDS RP2000 SERIES STANDS RP2028, RP2029 AND RP2029B POLYMER CONCRETE PADS WILLIAM A. SOMMERMEYER, CIVIL ENGINEER 1173-D EL CAMINO REAL - ARROYO GRANDE, CA 93420-2554 RCE 11658 exp.12/31/00 805/489-5380 APRIL 1998 SHEET 3 OF 3 SHEETS