Loading...
HomeMy WebLinkAbout066-030-01066-03-10. MICHAEL & SANDRA HETHERINGTON 6520 Shaw Circle lot C M Ralil ,.� 5, P C # Contr: Robert Da;ch /iW' 04 m ' �femm�it#256-2-85B-,-P-,,E, ',,new— -ing, e. . amfly B07-0924 0 -0301.10 MISCELLANEOUS . Addn -,F Stry. ADUBED EX IILL ERLING,E JR. & DEB o F A do i d� 1l PERMIT N0. 2562-85B P E M ~PERMIT EXPIRES ' t OWNER MICHAEL & SANDRA HETHERINGTON CONTR. Robert Dasch ASSESSOR PARCEL 66-03-10 LOCATION 6520 Shaw Circle, lot 35, PPCC#1 .y Maga lia t OFFICE COPY Address GA ate tMet , la.t .r ., OFFICE CO 7v?,vly a Addresses. G'6�tia% r GAS Meter By Date ELEDat CT l .' Meter �—��i ter OFFICE COPY I Temp. P p ' -Address Call �k^Meter'By Temp ` EI ti rr-- t ?�ELECTRIC't.:z ' Meter+By. Callc f � jjtt r' S Temp.. Gas Sei Called PG .e JOB FINALE[ Signature '�77 E� _ Permit' No.. LOCATION ROOF Material_ Thickness(inchea) ENERGY- C ERT I F I C A T I U N 6520 Shaw Circle , Magilia DESCRIPTION OF INSULATION EXTERIOR WALL Material. Fiberglass Thickness (inches)_ (+t CEILING Batt or Blanket Type Thickness (inches) Loose Fill Type rgiass Minimum Thickness (Inc13 )� 1+ Area covered(ft. ) 4 4 FLOOR, ELEVATED Material Fiberglass Thickness(inches)6 FLOOR, -'SLAB Material Thickness(inches) Width(inches) FOUNDATION WALL Material Thi.ckness(inches)r _ A.1'. No. Brand Naive __ Thermal Resistance (R Value) Brand Name Certainteed Thermal Resistance(R Value) R-19 Brand Name _ Tlrerrral Resistance(R Value) Brand Name Certainteed InsulsaFe- III Number of Bags_)_ Wt. per baj.64 lb. Thermal Resistance(R Value) Brand Name__ Certainteed Thermal Resisthnce(R Value) Brand Name Thermal Resistance(R Value) Brand Name Thennal Resistance(R Value)_________ I hereby certify that the above insulation was installed in the above building in c fz,,,ance with the State �c€ ��rifornia Energy Requirements. H444c ns InSujj,fion Co. \. Inc. SIGPIA' tl OF INSTALLATION APPLICATOR # 37 81107 STATE CONTRACTOR'S LICENSE NO. 4-7-86 DATE I hereby certify the above insulation and all required items as sh.own on the Building Department approved plans and attachments have been instal.le(I as required by the State of California Energy Requirements. All equipment, devices and materials are of the ejimlity prescribed or are specifically approve] by the State of California. 7 �d FI 1 111 IE WNE lea print) STATE CONTIUIC'.1101t'S LICENSE NO. GI ATURE OF (1ENERAL CONTRA UK OW1KR. DATE THIS CERTIFICATE MUST BE ON FILE, WITH T11E- BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION APPROVAL AND A COPY SHALL BE' P68TED WITHIN THE BUILDING . January 1984 COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correc n of work is completed. If you have any question pertaining to this matter, need additional explanation, please contact this office immediately. R, 14 C/ ,lea �- r /S Inspect itGf /fes%r —,mot) % e Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751' 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 Ik"CTION NOTICE A routine inspection indicates that the following violations of County Ordinance exist at the ove address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter or need additional explanation, please contact this office immediately. dim Inspector �;" / VI -l'. ' Date ,SS 16 � COUNTY OF BUTTE ' DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 89.1-2751 7 County Center Drive, Oroville — Phone: 534-4541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE zl C�' _RMI T NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office. immediately. � - L Inspecto _:ol Date i.46 �'. COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 89.1-2751 / 7 County Center Drive, Oroville — Phone: 5344541 Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWNER PERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter r need additional explanation, please contact this office immediately. a-uTo z r'6 N) s Inspector_._. Al", Date—y�- SEX -76 : f ' i £��c�� c✓' a����f Sc��et � COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville •- Phone: 534A541 f Skyway and Elliott Road, Paradise — Phone: 872-2961, Ext. 57 CORRECTION NOTICE OWN E F1 ERMIT NO. A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this mneed additional explanation, please contact this office immediately. £,-r £ ,' It JS 4-/d f / /6 w 91 AW y Wrsf 4/c 1 7c &1— ti ZVI v� l£ %t ^ £tsrLltl.�(i _ 4it £ic 10C„1W, 6�7� 7�LI'tii Inspector Date COUNTY OF BUTTE DEPARTMENT OF PUBLIC WORKS - 196 Memorial Way, Chico — Phone: 891-2751 7 County Center Drive, Oroville — Phone: 534-4541 �r A routine inspection indicates that the following violations of County Ordinance exist at the above address and should be corrected. Please notify this office when correction of work is completed. If you have any question pertaining to this matter, or need additional explanation, please contact this office immediately. Inspector i!/ Date V =OK 0 ANot OK Not Applicable Not Ready RESIDENTIAL -(Single and Duplex) (NOTE:Anentrymust be made each time you visit jobsite) Date UNDFq OOR Plans OK exce t#'s Date FRAMING (Continued) 1. 0'6n jag requirements -Setbacks -Easements 4 Firewall & Openings Zwlft :, Main; Soils -Steel- .- / Ftg. Depth xt. Doors- - heck Garages ry, ext s Garage; Soils -Steel- / /" Ftg. Depth 50 S irs; Width -Headroom -Rise -Ru -Lan t rote Lion 4 t ., Porches & Decks; Soils -Steel- / /" Ftg. Depth PI ood Overhang tti t f er' i 5 to IIs, Main; Steel-Blockouts-Wrapped-Slab Siding g-lfeweer 6 AST onfw-alls, Garage; Steel-Blockouts-Wrapped-Slab-68. rip Screed-Fdn. Vents-Underflr. Access 7.Piers-Fireplace Ftg.-Steel azing Area -Glass Protection -Skylights -Plastic :W.V.: F&f---riUojv­T way C/O -Se est alls; Nailing -Bolts as Pipe; Size -Anchors Pflatcrr-Pipe; - rs-Re r-Serv' est / ums D Clearanc aterial-Support-Ins. ' Gi - i nc o JWsis-Vents-Gsipples Card -,BI Card -BI Dat -Z Card -BI Date Date i Card -BI Date -� GV A &/;,/4( 4 f!, jVj Card -BI a Card- Date Card -BI p+ Daaeans) Date Card -BI Date OK except q's Card -BI DateCard-BI Date DateING (Per 't) 0 kept q's eps-Door &Sidelight Protection -La gs Jd''r 5 mok etector er Ht.;• s 58 , pace; Vents -Clearance -Comb. Air -Connector- a In.Gwage; Above Floor-Ducts-Mech. Protection Water Pipe; Test &Aaefdrs-Nail 8seteCtion 1 W.V.; Test-Fttngs & rs-NaihGfaTection S E om Exiting 1 t, First F ub Access 6 G.F . & Bath Fixtures & Tub Access 9 Tub Access . rim & Subpanel; Breaker Sizes -Labels Gas Pipe; Size & Anchors ta' & Rails 63. it ce or Stove; Clearances -Hearth 64L,eT weOutlets at Wood Panel; Int. & Ext. Card -BI DatCard-131 Date 6Ki Fixt. & Appliance; Grnd.-Air Gap -Cooking Clearance Card -BI DatCard-BI Date 6belflape,56tiets & Receptacles at Kit. Counter Date ELE ICAL Permit OK except Ws 67 arage Fire Door; Swing -Landing -Closer in Garage -Damper ' ga Fixture & Transformer Clearance -Ins ection / 6 tr. Htr.; Vents -Clearance -Comb. Air -Connect - In Gar e; Above Floor-Mech. Protection lec. Ree sSpacing-Lights es at Doors Zgff2jze oxes & No. of 70. P ., Elec. & Mech. Equip. Listed for Location mex Installed Close to Ed of Studs & C.J. a to Edq?,ofSt Studs 7 lec. Receptacles in Garage; (G.F. Romex Protec. 13REqu i -Looked i is Q� uard rai IsA Deck Coon -Post Caps A pliance Circuits in Kitchen &Conductor Size f ga. Cu or AI-A.C. Wire Size / ga. Gtr AI W 7 n. Vents & Crawl Hole Door -Drainage & Wood -Earth Clearance Loo er Floor ❑Yes G R rc ga. C or AI ❑No � Q� - mellowing _ instld.: Drive/E� Walks ❑ Yes No; Planters ❑Yes ❑No y/ Service ise ductor Gr Main Disconnect 7 - rown-Finish quip. Clearances; Panels-Motors-Mech. Equip, 77 A.0 ;Disconnect-Clrnces-Brkr. & Cond. Size -115V Outlet 39. 81 ght-Shower Light 781 --Tents Above Roof; Plbg.-Appliance-Firepl.-Clearance to Opngs. r Well; Disconnect, Electrical, Plumbing 8 . Ep6rior Elec. Trim; G.F.I. Receptacle -Underground Card B-IDate ZG Card -BI Date ij�dl g 8 ilation throughout House GI ss Protection Card B-Ij Date �� Card -BI Date Date Nf6p±NICAL (Permit) OK except k's orrections from Previous Inspections G—est—meters Tagged; Gas-Electric A,C Ducts; Insulation & Support 85 a er & Sewer Connected -C/O to Grade -HD Approval g r ent Fan; Exhaust above Insulation(0_5r"/--§6t,#I5nergy Compliance Certificate -Other Certificates ain & Overflow; Size & Grade 34:7-F nTmee-Kent; Access -Comb. Air -Return Air Vent -115V outlet 35�eeess & Platform if Furnace in Attic If Card -BI Card- Card -BI Dat and -BI Date Date Card -BI Date Dat Card -BI Date Card -BI Date Card -BI a DateV- c =aJ6 Card -BI Date C Card -BI Date Date FRAMIN Plans OK except q's Comments at Final: 3 ills• Proper Material & Anchors %f 4/ G FLE alls; Studs -Nailing, Spacing & Bracing-Plates-Seartd— 1A.J£ ring Walls over Girders & Floor Nailing 20-Orgrt Stop in Walls (rat proof) Sto s; Fur ss6teirs- es- eader &B eam-Size & Bearing 4g_ -Post Caps -Anchors -Connectors %i i - -Ro 3.rac. T s _ - Rfn_g_.__ Fi or -Fir W=aZAg^a— ttic Acc ize & Rome ection-4Lam'stop-I B 4 m. Windows or Exiting Doors -Sill H@L-L434inensions image Fire Protection Framing (NOTE:Anentrymust be made each time you visit jobsite) J - OK 0 = Not OK = Not Applicable MOBILEHOMES * = Not Ready r. MISCELLANEOUS Date MOBILEHOME UTILITIES (Plans) OK except N's 1. Zoning Requirements -Setbacks -Easements Date DECKS, COVERS, CARPORTS, ETC. (Plans) OK except N's 1, Zoning Requirements -Setbacks -.Easement 2. Soils; Special MH Support -Sketch 2. Footings; Size -Depth -Spacing -Connectors 3. Sewer; Location -Test -Fall -C/0 -Concrete 3. Decks; Girders and/or Joists -Decking -Bracing -Stairs -Rails 4. Water; Location -Test -Easement Needed (Sketch) 4. Wood Awn.; Posts-Beams-Rftrs.-Connec.-Shthg.-Rfg.-Bracing 5. Electricity; Location-Clearances-Grnd.-/ / Amp -Concrete 5. Alum. Awn.; Columns -Connections -Splice -Decal -Enclosures 6. Gas; Location.Test-Wrap:/ /"L"ft./ /"Nat.or/ /"L"ft./ /"LPG 6. Carports; Windows -Doors 7. Utility Clearance 7. Elec. Card -BI Date Card -BI Date Card -BI Date Card -BI Date Card -BI Date Date Card -BI Date MOBILEHOME INSTALLATION (Plans) OK except a's 1. Zoning Requirements -Setbacks -Easements Card -BI Date Date Card -BI Date POOLS (Plans) OK except N's 1. Setbacks -Easements 2. Footings; Size -Spacing -Marriage Line 2. Soils; Compaction -Structure Stability 3. Gas; MH`Test-Demand-Valve-Connector 3. Pool Structure; Steel -Connections -Thickness -Dead Men -Lining 4. Electricity; MH Test -Crossovers -Breakers -Clearances 4. Elec.; Receptacles and Lighting; Distances-GFI 5. Drain; MH Test -Fall -Flex Connector 5. Elec.; Pool Lighting; 15 volts -GF] 6. Water; MH Test -Regulator -Connector 6. Elec.; Enclosures; Conduit Entries -Terminals -Listed 7. Water and Sewer Connected -C/0 to Grade -HD Approval 7. Elec.; Bonding; Metal w/5' -Circulating Equipment -Heater 8. Gas and Electricity Tagged B. Elec.; Grounding; Equip. w/5' -Circulating Equip. -Pool Lghtg. Boxes -Enc losures- Pane lboards-Ins. to Main in Conduit 9. Exits; Insp.-Sketch ,. 10. Cert. of Occupancy 9. Health Department Approval 10. Plumb; Cir. Test -Water Supply Test Card B-1 Date Card -BI Date Card -BI Date Card -BI Date Card B -I Date Card -BI Date Card -BI Date Card -BI Date ✓ COUNTY OF BUTTE - DEPARTIMENT OF PUBLIC WORKS YERMI)r NO.. — 7 County Center Drive - Oroville, California 95965 - Telephone 916/534-4541 5�/, APPLICATION AND PERMIT V- ASSE R PARCEL NUMBER ZONI G BUILDING PERMIT ow R V / TELEPHO E — SQ. FT. OCC. BUILDING VALUATION OV/N MA I G�DDO !Ij 1 a ' 96 ©' CON ACTOR'S NAME TE EPIMN l00 C TRAC OR'5 M 'ILINIG ADDRESS Fireplace 00 CONSTRUCTION Y_E!NCJER UNKNOW Total Valuation Is 6,1 Filing Fee $ 10,00 LENDER'S MAILING ADDRESS Permit Fee $ ARCH ECTT�/OOR' ENGINEER LICENSE NO. Plan Checking Fee $ / Energy Plan Checking Fee $ /15,00 ARCHITECT OR ENGINEER'S MAILING ADDRESS Penalty $ BUILDING ADDRE 5 Permit fee $ d, S` PLUMBING PERMIT Filing Fee 10.00 Each Trap 2.00 / , Solar or heat pump water heater 20.00 LOT NO.SUBDIV 10 NAMEARCEL MAP Water piping 5.00 is O Each qas water heater or vent 5.00 po USE OF STRUCTURE SFDuplex❑ Mobilehome❑ Other SPECIFY Gas piping system 1 - 5 outlets 5.00 &.00 Building sewer 5.00 ,00 Mobile Home Is G W 10.00ea TYPE OF WORK Ne Addition ❑el❑ Utilities❑ Installation❑ Other [I Describe work: _ Permit Fee $ Contractor ELECTRICAL PERMIT Filing Fee 10.00 Main service SOOV OR LESS 100 AMP OR LESS 10,00 Main service EA. ADD'L 100 AMP 2.50 CONTRACTORS LICENSE LAW I declare under penalty of perjury (Check One): El am licensed under provisions of Chapt. 9, Div. 3 of the Business and Profess' s C�o• a d my license is in full force an effect. YVV�IO License No. Classification I, as the owner, or my employees with wages as their sole compen- ation, will do the work,and the structure is not intended or offered for sale. (Sec. 7044) ❑ 1, as the owner, am exclusively contracting with licensed contract- ontract- ors. ors.(Sec. 7044) ❑ I am exempt under Sec. , Business and Professions Code for this reason NEW CONST. DWELLING OCCUFr.COR ADDNS. ( ACC. SLOGS. , "sq ft NEW CONSTR. MULTI -OUTLET 2,50 ea NON•RESID BRANCH CIRC ITS POWER APPARATUS .&) (SINGLE OUTLET CIR. Ex. OCcup(OUTLETS OR FIXTURES 20050Q SAL@30 FIXED APPLNS. OR EX. Occup. OUTLETS (RESID.) EA.1 2.00 Temporary service 10.00 Mobile Home Facilities 15.00 Misc. IVirin 15.00 g Permit Fee $ Contractor WORKMEN'S COMPENSATION INSURANCE I declare under penalty of perjury (check one): ❑ The permit is for $100.00 (valuation) or less. I have. placed on file with the County of Butte Building Department /-'-,a Certificate of Workmen's Compensation Insurance or a Certificate of Consent to Self -Insure. ❑ I shall not employ any person in any manner so as to become subject to the W. C. laws of California. Notice to Applicant: If after making this statement, should you become subject to the W. C. provisions of the Labor Code, you must forthwith comply with such provisions or this permit shall be deemed revoked. MECHANICAL PERMIT FiIingFee 10.00 Heating Cooling g Hood 3.00 Ventilation permit Fee $ Contractor I certify that I have read this application and state that the above information 's correct. I agree to comply to all County Ordinances and State Laws relating to building construction, and hereby authorize representatives of the Countyot Butte to enter upon the above-mentioned property for inspection purposes. 1 also agree to sav ,indemnify and keep harmless the County of Butte against all liabilitie ju ents, ts, and expenses which may in any way accrue against u in co equence of the granting of this permit. X Date ��� Signature of Applicant — Owner ❑ Cantracto��Rgent ❑ An OSHA permit is required for excavations over 5'0" d olition or construct- ion of structures over 3 stories in height. Mobile Home Installation Fee $ Energy Inspection Fee $ TOTAL PERMIT FEE $ o�c2. /� c'�,.T,YPE v N F o PARCE PD H s90E This permit is hereby issued under sions of the Butte County Code and/or work indicated above for which DIRECTOR OF PU LIC o Y PERMIT EXPIRES Date the applicable provi- resolutions to do fees have been paid. WORKS Date �' Receipt No. I 00 WHITE-D.P.W.. TEL LOW -ASSESSOR IN - 9PECTO OLDEH ROD -APPLICANT COUNTY OF BUTTE - DEPARTMENT OP:PUBLIC WORKS - BUILDING DIVISION Y 7 COUNTY CENTER DRIVE - OROVILLE-CALIFORNIA 95965 - TELEPHONE: 916/534=4541 PERMIT APPLICATION DATA SHEET n� 114ion i Permit No. OWNER /t/ i �1L 4r vin T A. P. No. Proposed Building Use ���L7 Permit Fee Based Upon: CompleteContract Price _T—DPW Valuation Building Inspector / y� Date 5 .y 7 , At time of permit application, I was advised the following data must be submitted prior to permit processing and:/or issuance: DATE RECEIVED. APPROVED 1. All items have been submitted. . . . . . . . . . . . 2- Plot plans in duplicate./triplicate. . . . . . . . . . . 3. Complete plans in duplicateltriplicate. . . . . . . . . 4. Complete engineered plans and calcs. . . . . . . . . . 5. Plans with Energy Design Compliance Statement. . . . . . 6. State Energy Forms No. Statement of Intent for Non -Heated and AC Buildings. Fees of $ 404 Q n . . . . . 3 9. Letter of signature authorization. l Sanitation approval from PI) rl-HeaIth Dept. 1Planning approval for (A) Use: (B) Parking: — 2. Certificate of Workmen's Compensation Insurance. 13. Contractor's License Information 'no., name style, classif.) 14. Owner -Builder Verification (Given to owner[], Mail to owner [] ) 15. Improvements may be required. . . . . . . . . . . . 16. Mobilehome Installation Data. . . . . . . . . •Pre-Inspec. request to (Date% 1,7 Pre -Inspection for Required. Building Inspector d} 8 Recorded copy of Agricultural AcF:nowledgment Statement. X13 19. Other Wheyn you issue the permit, process as follows: Mail to owner. Mail to contractor.OrN Telephone nd hold for pickup aroffice. Deliver w. /inspector. Other _t Applicant .// Y /- " v Date Copy of plans sent Health Dept., Fire Dept., Other Date During the plan checking process, the following data must be submitted prior to permit issuance: (For required items not checked above aV aication, circle item.) 1. Index permit for above Items No. 2. Additional items required: (C11---) '.1 Designer Owner) was advised cf above required da�.ta, b�r - Telephone Mail r Other By + Date � rr?ay�_ Plans checked b� Date Plans approved by Date Sep es Other: r (L 4 r s r Copy—DPW T0, Building Department FROM: Environmental Health SUBJECT: SANITATION CLEARANCE OWNER LOCATION AP # Plans approved for: Sewage Disposal Y Water Supply Hold final for: Water Supply Final Clearance O.K. for: Water Supply Clearance for bedroom ame- home. Other Clearance for addition of No t SANITARIAN DATE TO: Building Department FROM: Encroachment Permit Section RE: Driveway Clearance In, -ti,,-el Mete, -,o, W1,5z o Shww owner. location 40�,(5�- 03-/0 AP # Driveway permit 33 - has been issued for the above property. d 3 signat Lv6 date Return to DPW AGRICULTURAL STAZ M>aNT., OF ACKNOWLEDGEMENT EU7TE E.11EQUEI AIIFOR�I AT Tt�.. REQU..ST OF FOR ,RESIDENTIAL DEVELOPMENT PARTS SHOWN Section 26-8.1 of the Butte County Code requires this acknowledgement 1285 SEP 23 PM 1: 32 be recorded'prior•to issuance of a building permit. The property described herein is adjacent to land or included LECORD KcR within an area zoned for agricultural purposes, and residents of CLERK -ELEANOR RECORDFrE_ this property may be subject to inconveniences or discomfort arising �5�2881i� from the use of agricultural chemicals, including, but not limited to herbicides, pesticides, and fertilizers; and from the pursuit of agricultural operations including, but not limited to cultivation, plowing, spraying, pruning, and harvesting which occa- sionally generate dust, smoke, noise, and odor. Butte County has established agricul- tural zones which have as a priority use for productive agricultural purposes, and residents within said zones and om adjacent property should be prepared to accept such inconvenience or discomfort from normal, necessary farm operations. All that real property situate in the County of Butte, State of California, described as follows: RP ADI S P1 I,J£ S C C)( -f LU is e bTATf S U PJI r 1 } _ UT l 6 ��\a."-) C Date: September 23, 1985 �'Y-\c�gaIICA, PROPERTY J State of California ) On this the 23rd. day of September , 19 85 SS. before me, the undersigned N tary Public ersonally County of Butte ) appeared V ®��®v■■ve■■■��■■r°���01■■9®known to subscribed e ribedtoothe within be the rinstrument sand aacknowledged a a DEBT Luceno that she executed the same for the purposes ■ �' NOTARY PUEL{O. 4UF0AMA,. therein contained. CVM■ K`ki ® MYcort Buft'*ft IN WITNESS WHEREOF, I hereunto set my hand and official �o�..�.i� � !\\\\i«iIL��seal. �118��°� ����'s V it °QDE-01 LUCERO ■ ■ O NOTARY PUBLIC-CALIFORNIABuite Count; My Commission Expires Dec. 26,1987 O ■ Present A.P. NO. kk — 0 CP 7) (� Notary Public RESIDENTIAL PLAN CHECKING'GUIDE `-(S.F:, DUPLEX & MISC. ONLY) . Bldg. Permit # M Zrfr OWNER 1W/C#At Z- #67#6&A167 &A16 A . P. # 0 4 Z _0 JT 6 GENERAL Ir. Zoning requirements: (sideyards and number of permitted living units). Jar3z Valuation. . Plans signed by designer. Energy Design and Compliance.' Existing violations on property. PLOT PLAN Complete parcel size and dimensions. Setbacks, sideyards, easements, etc. ;;-6- Other buildings or structures. Grading, fills, drainage. Flood hazard. ,¢! Special conditions on creation map or compliance document. FLOOR PLAN 7/85 1: Complete to scale plan with dimensions. 2� Required windows for light and ventilation (Sec. 1205). Required windows for second -exit (Sec. 1204) . Skylights (Chapter 34 & Sec. 5207). ,50 Human impact glass (Sec. 5406). Required room sizes, ceiling heights (Sec. 1207). `7! G.F.C.I.'s in baths, garage and exterior outlets (Article 210-8). 8! Light fixtures, switches, receptacles, and exterior receptacles for maintenance of mechanical equipment. Locations of water heater, heating and cooling equipment, other electrical or gas equipment, and plumbing fixtures. Garage firewall, door size, and closer (Sec. 503(d)(3).). }�. 1 - 3'0" exterior exit door (Sec. 3304(e)). Fireplace and wood stove location. ,Y3. Smoke detectors (Sec. 1210). STRUCTURAL DETAILS 2A Foundation plan complete enough -.-to construct building. 1" Floor construction details complete enough' -.to construct building. 3- Elevations and wall construction details complete enough to construct building. �4! Roof construction details complete enough to construct building. Fireplace construction details and calcs if necessary. 6! Sufficient data and details to satisfy energy requirements (State Law) (Form 1). MISCELLANEOUS ITEMS TO LOOK OUT FOR Exposure I plywood on exposed locations and overhangs. ,2! Stairway details: landings, rise and run, head clearance, handrails (Sec. 3306). Guardrail details (Sec. 1711 & 3306(j))., a Brick or stone veneer (Chapter 30). `e. Exterior plaster - weep screeds,(Sec. 4706). Proper roof pitch for roof covering (Chapter 32). dY. Rafter ties or bearing ridge beam. RESIDENTIAL PLAN CHECKING GUIDE (CONT'D) l - MISCELLANEOUS ITEMS TO LOOK OUT FOR (CONT'D) Garage door or porch header sizes. A Adequate bracing. LGI Living area over garage - complete 1 -hour separation required on garage side including supporting walls and posts, etc. 1 Two exits on three-story dwellings (Sec. 3303 & see Mezannines 1716). All. Attic access and ventilation (Sec. 3205). 1,4. Underfloor access and ventilation (Sec. 2516). �Il . Wood stoves, clearances, alcoves & 1 -hour shafts. 15! Combustion air for fuel burning appliances. 1.60. Noise requirements on duplexes. 17le Adobe soils - special foundation design. 18'0. Retaining walls requiring design. Unusual shape, size or split level house requiring lateral design. 0 7/85 TOTAL POINTS = Ho 'able 3-1. Slab Floor Points I T- I Inc.zla- I R -Value of Insulstlon I I ttun 1 I ! Depth, -j 1 inches 1 0-2 13-4 1 5-6 1 7+ I 1 0-111-5 1-5 I-5 I-5 I 12 - 15 1 -5 1 -3 I -2 i -1 I 16 - 19 I -5 j -2 1 -1 I 0 I 20 + I -5 1 -1 1 0 1 +1 7/7/83 Table 3-3a. Ceiling Insulation Points R -Value of Insulation I Points 19 I -4 22 I -2 30 I 0 38 I +2 49 ( +4 Table 3-4a. Ball Insulation Points I R -Value of Insulation I Points I I 19 I 0 ! 30 i +3 Table 3-5. North-FacinR Glazing Pte T- I Glazing Type 1 I Total I 1 I Z of I Sngl, I Dbl, I Trpl, I Floor I U- I U- l u- ! Azea 10.66 ! 0.42- ( 0.41 I I 1 1.10 i 0.65 1 dove ! O •4 +4 ♦. I 0.1- 1.2 I +4 ! +4 ! +4 I I 1.3- 2.3 ! +1 I +2 I +2 i 1 T.4- 3. - I - 4.8 I -4 ! -2 ! -1 ! I 4.9- 6.1 1 -7 I -4 1 -3 I 1 6.2- 7.3 I -9 I -6 I -5 1 7.4- 8.2 i -12 1 -8 ! -7 ! 1 8.3- 9.7 1 -14 1 -10 I -8 ! I 9.8-10.8 1 -17 1 -12 I -10 I 110.9-12.0 ( -19 1 -14 1 -12 1 112.1-13.2 1 -22 1 -16 I -13 1 13.3-14.5 I -24 1 -18 I -15 I 14.6-15.3 i -27 I -20 I -17 I South -Facing Glazing Pts Table 3-10. Shading Ce FFf.t.,.. o-. I Glazing Type I I Total I 1 Z of I Sngl, I Dbl, Trpl, I Floor I (U - I (U - I (U - ! I Area 11.10) ! 0.65) 1 0.41)1 II olnts !paints I ointsl o +s +g • 3 I up to 1.5 I +2 1 +2 I t2 I I 1.6- 3.6 I -1 I L 0�) 1 0 I I SI -4 I .-2 1 -2 I 5.3- 6.5 I -6 I -4 1 -3 I I 6.6- 7.7 1 -9 I -6 I -5 I 1 7.8- 8.9 I.-11 i -8 I -7 1 I 9.0-10.0 I -13 1 -10 .! -9 1 110.1-11.5 I -17 I -13 I -11 I 111.6-13.0 I -21 I =16 I -14 I 113.1-14.5 I -25 I -19 I -16 I 114.6-16.0 I -28 1 -22' I -'.9 I Table 3-8. West-FaclnR Clazin Pts. I Glazing Type ! 1 Total I I Z of I Sngl, I Dbl, Ttpl(u, I Floor I (U - I (U - I - I I Area 11.10) 10.65) 1 0.41)1 I I oints I ointsI ointsl o •6 •6 +6 I up to 1.3 I +5 I +6 1 +6 i 1 1.4- 2.2 I +3 1 +4 ! +5 I 2.1- 2.8 1 0 1 2.9- 3.6 I -3 1 Fes- 4.2 -5 4.3- 5.0 I -8 1 5.1- 5.6 I -10 5.7- 6.2 i -13 I 6.3- 6.9 I -15 I 7.0- 7.6 I -18 1 7.7- 8.2 I -20 I 8.3- 8.8 i -22 I 8.9- 9.5 1 -25 I 9.6-10.1 ( -27 10.2-11.0 I -29 I 11.1-11.8 I -35 I 11.9-12.7 I -38 I 12.8-13.5 i -42 I 13.6-14.3 ! -46 I 14.4-15.2 I -50 I -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -23 -26 -29 -32 -35 -33 1 +3 I P +1 I I 0 I I -2 i -4 -6 I -7 i -9 I -11 I -13 I -15 I -16 I -17 -21 I -24' I -27 I -29 I -32 I Table 3-9. Skylight Points Table 3-6. East -Facing -Glazing Pts. I I Glazing Type I I Glazing Type I I Total I 1 - --1 Total I I I Z of T Sngl, I Dbl, Trp1, I Z of I Sngl, Dbl, Trpl, I Floor I U- I U- I U- I Table 3-2. Raised ZONE 11 I Floor I (U - / OWNER 70A) POINTS I Area 1 PERMIT NO. _2156 2'85- ASSIGNED ACTUAL 1. SLAB - INSULATION I Area -- 1 0.65).1 0.41)1 1 11.10 I 0 ► 0 ( Q0 2. RAISED FLOOR - R-19 /109 0 3. CEILING - R-30 'b•OD 0 4. WALL - R-19,O''/U 0 -.18 0 VE 5. NORTH GLAZING - 2.4-3.6% ?•&7 O 6. EAST GLAZING - 2.5-3.6% 71t _/0 7. SOUTH GLAZING - 1.6-3.6% /'76 0 S. WEST GLAZING - 2.9-3.67 +4 1 I 1.4- 2.2 I 9. SKYLIGHT - 0-1.37 -1 I 1 0 1 -1 I -3 1 -6 1 -7 10. SHADING (Exclude Overhang) +1 1 +2 1 +2 1 EAST - .66 -6 I -4 I -3 I SOUTH - .19-.42 46 0 -2 WEST - .13-.36 gyp(. =3 -9 SKYLIGHT - .37-.57 -5 I I 3- 4 11. HORIZONTAL SOUTH OVERHANG 2' Z� U 12. MOVABLE INSULATION - NONE -11 I -8 I 13. INFILTRATION (Standard=0)(Tight=+12)• ( -6 I I 4.7- 5.6 I 14. THERMAL MASS SF -3 1 ! 4.3- 5.0 I 15. GAS FURNACE (SE) 71-767 -8 I � 16. !-TEAT PUIIP (EER) 7.5-7.9% -10 I -6 I 17. DUAL PACK (SE, SEER) 8,0-8.3/71-76% -16 �- -10 I WOOD STOVE YE S f Zy LR 4 AS WATER HEATER I - I 0 I 5.7- 6.2 1 ATTIC ou 7. I -14 I 3 I •19+ OTHER . I I 7.8- 8.7 1 -1 TOTAL POINTS = Ho 'able 3-1. Slab Floor Points I T- I Inc.zla- I R -Value of Insulstlon I I ttun 1 I ! Depth, -j 1 inches 1 0-2 13-4 1 5-6 1 7+ I 1 0-111-5 1-5 I-5 I-5 I 12 - 15 1 -5 1 -3 I -2 i -1 I 16 - 19 I -5 j -2 1 -1 I 0 I 20 + I -5 1 -1 1 0 1 +1 7/7/83 Table 3-3a. Ceiling Insulation Points R -Value of Insulation I Points 19 I -4 22 I -2 30 I 0 38 I +2 49 ( +4 Table 3-4a. Ball Insulation Points I R -Value of Insulation I Points I I 19 I 0 ! 30 i +3 Table 3-5. North-FacinR Glazing Pte T- I Glazing Type 1 I Total I 1 I Z of I Sngl, I Dbl, I Trpl, I Floor I U- I U- l u- ! Azea 10.66 ! 0.42- ( 0.41 I I 1 1.10 i 0.65 1 dove ! O •4 +4 ♦. I 0.1- 1.2 I +4 ! +4 ! +4 I I 1.3- 2.3 ! +1 I +2 I +2 i 1 T.4- 3. - I - 4.8 I -4 ! -2 ! -1 ! I 4.9- 6.1 1 -7 I -4 1 -3 I 1 6.2- 7.3 I -9 I -6 I -5 1 7.4- 8.2 i -12 1 -8 ! -7 ! 1 8.3- 9.7 1 -14 1 -10 I -8 ! I 9.8-10.8 1 -17 1 -12 I -10 I 110.9-12.0 ( -19 1 -14 1 -12 1 112.1-13.2 1 -22 1 -16 I -13 1 13.3-14.5 I -24 1 -18 I -15 I 14.6-15.3 i -27 I -20 I -17 I South -Facing Glazing Pts Table 3-10. Shading Ce FFf.t.,.. o-. I Glazing Type I I Total I 1 Z of I Sngl, I Dbl, Trpl, I Floor I (U - I (U - I (U - ! I Area 11.10) ! 0.65) 1 0.41)1 II olnts !paints I ointsl o +s +g • 3 I up to 1.5 I +2 1 +2 I t2 I I 1.6- 3.6 I -1 I L 0�) 1 0 I I SI -4 I .-2 1 -2 I 5.3- 6.5 I -6 I -4 1 -3 I I 6.6- 7.7 1 -9 I -6 I -5 I 1 7.8- 8.9 I.-11 i -8 I -7 1 I 9.0-10.0 I -13 1 -10 .! -9 1 110.1-11.5 I -17 I -13 I -11 I 111.6-13.0 I -21 I =16 I -14 I 113.1-14.5 I -25 I -19 I -16 I 114.6-16.0 I -28 1 -22' I -'.9 I Table 3-8. West-FaclnR Clazin Pts. I Glazing Type ! 1 Total I I Z of I Sngl, I Dbl, Ttpl(u, I Floor I (U - I (U - I - I I Area 11.10) 10.65) 1 0.41)1 I I oints I ointsI ointsl o •6 •6 +6 I up to 1.3 I +5 I +6 1 +6 i 1 1.4- 2.2 I +3 1 +4 ! +5 I 2.1- 2.8 1 0 1 2.9- 3.6 I -3 1 Fes- 4.2 -5 4.3- 5.0 I -8 1 5.1- 5.6 I -10 5.7- 6.2 i -13 I 6.3- 6.9 I -15 I 7.0- 7.6 I -18 1 7.7- 8.2 I -20 I 8.3- 8.8 i -22 I 8.9- 9.5 1 -25 I 9.6-10.1 ( -27 10.2-11.0 I -29 I 11.1-11.8 I -35 I 11.9-12.7 I -38 I 12.8-13.5 i -42 I 13.6-14.3 ! -46 I 14.4-15.2 I -50 I -2 -4 -6 -8 -10 -12 -14 -16 -18 -20 -23 -26 -29 -32 -35 -33 1 +3 I P +1 I I 0 I I -2 i -4 -6 I -7 i -9 I -11 I -13 I -15 I -16 I -17 -21 I -24' I -27 I -29 I -32 I Table 3-9. Skylight Points Table 3-6. East -Facing -Glazing Pts. I I Glazing Type I I Glazing Type I I Total I 1 - --1 Total I I I Z of T Sngl, I Dbl, Trp1, I Z of I Sngl, Dbl, Trpl, I Floor I U- I U- I U- I Table 3-2. Raised Floor Points I Floor I (U - I (U - I (U - I I Area 1 0.66- 1 0.42- 1 0.41 I T 1 1 6.3 I Area 1 1.10) 1 0.65).1 0.41)1 1 11.10 I 0 ► 0 ( Q0 i 0.65 I down I 1 R -Value of i ( I 1,�o!nts !points ! ointsl i to I to i' to I to I up I I 3. 16.3 17.9 19.5 I 0 -.18 I Insulation I Points I+ 7 + 4 +< I up to 1.3 I -1 I 0 I 0 I I I I I up to 1.3 I +3 1 +4 1 +4 1 I 1.4- 2.2 I -3 I -2 I -1 I 1 0 1 -1 I -3 1 -6 1 -7 .58-.821 I 1.4- 2.4 I +1 1 +2 1 +2 1 I 2.3- 2.8 ( -6 I -4 I -3 I I below 3 i -12 I I 2.5- 3.6 I -2 I 0 1 0 1 I 2.9- 3.6 I -9 I -6 1 -5 I I 3- 4 I -8 i 1 3.7- 4.6 1 -5 I -2 I -1 1 ( 3.7- 4.2 I -11 I -8 I -6 I I S- 7 ( -6 I I 4.7- 5.6 I -8 I -4 I -3 1 ! 4.3- 5.0 I -14 1 -10 I -8 I 8- 12 I -4, I I 5.7- 6.7 1 -10 I -6 I -5 1 1 5.1- 5.6 I -16 I -12 I -10 I I 13 - 18 1 r2 I I 6.8- 7.7 1 -13 I - I -7 I I 5.7- 6.2 1 -19 I -14 I -12 I I •19+ I 0 I I 7.8- 8.7 1 -1 1 I -6 I I 6.3- 6.9 I -21 I -16 I -13 I ( I 1 1 .8- 9.7 1 -1.7 1 -12 I -10 I I 7.0- 7.6 I -24 I -18 I -15 I I 9.8-11.2 I -21 I.-15 I -13 1 I 7.7- 8.2 I -26 I -20 I -17 i 111.3-12.7 1 -25 I -18 I -15 I I 8.3- 8.8 I -28 1 -22 I -19 I 112.8-14.0 I -28 I -21 I -18 I 1 8.9- 9.5 I -31 I -24 I -21 I 14.1-15.3 I -32 I -24 1 -20 I I 9.6-10.1 I -33 I -26 I -22 I +-- ----- 4-- - 4 -- - I- ------�--- - -- J-- ( SC by I Orten- 1 Z Floor Area T. tation I Easti I 3.2-j ; I 1 0-3.1 1 to 6.4 7-p I 1 1 6.3 I 0 -.19 I 0 ! +1 I +2 I .20-.36 I 0 I 0 I i1 I 37-:66 I 0 ► 0 ( Q0 ( .67-.82 I 0 I 0 ! I .83 up i 0 i -1 1 -2 I I South 1 1 0 1 3.2 1 6.4 1 8.0 19.6 I i to I to i' to I to I up I I 3. 16.3 17.9 19.5 I 0 -.18 1 0 1 +1 I +2 1 +T 2 +3 I .19-.42 Il 0 1 0 1 0 1 0 1 .43-.66 I�I -1 I -2 1 oZ I -3 I .67 up 1 0 1 -2 I -4 I -4 I -6 West I .1 I } 6 13.2 16.4 19.0 I to I Eo i to I to I up 11.5 13.1 16.3 1 7.9 I I I I I I 0-.12 i 0 1 +1 I +3 1 +6 I +7 .13-.36 i 0 I 0 I 0,1 0 1 0 .37-.57 1 0 1 -1 I -3 1 -6 1 -7 .58-.821 -1 I .-6 I -12 I -15 .83 up 1 -2 I I -8 I -16 I -.70 I I I I I Skylight i .1 I .8 11.6 1 3.2 ! 4.0 i to I to I to I to I to . I�7 _Irt.s IT 3.113.9 5_2 0-.12 1 0 1 +1 I +3 I +6 1 +7 .13-.36 1 0 1 0 1 0 1 0 1 0 .37-.57 1 0 1 -1 I -3 1 -6 1 - .58-.82 I -1 I -3 I -6 I -12 I -. .83 up I -2 I -4 1 -8 I -16 i -20 Table 3-11. Horizontal South Overhane Points South Glazing Length Out ! Area, Z of Floor I fromWalltT- ! I 1 0-6.3 I 6.4 up I I I I I 0 - 0.5 1 -2 74 1 0.6 - 1.0 I -2 I -3 I 11.1 - 1.9 I -1 I -2 I 2.0 up i 0 I U I Table ]-12. Movable Insulation I Points Moveable Insulation] ! I Area, Z of Floor I Points 1 I I I 0- S. S I 0 !' I 5.6 - 11.5 1 +2 1 I 11.6 - 17.5 I +4- 17.6 4 17.6 - 23.5 I +6 1 I 123.6+ I +8 1 J_..---- -...._... i Table 3L13- Lnf)ltratlon Control Feett-res Points Cqm-rol Features I Points I T- I Standard 1 0 I 11.9 air changes per hr I I T- i 1 Tight i +12 10.6 air changes per hr 1' t Table 3-15. Cas Furnace-Vithout Refrigeration Ci2lIng Points 'I -Seasonal Efficiency I Points I („E)_' t I I I I j- 71 -76 I 0 - I 77 - 82 ( +2 I I 83 - 88 I +4 I I 89 - 94 !. +6 I 95 up i +8 Table 3-16. Heat Pumo Points r Energy.tfficiency I Pointe I I Patio (EER) I I I ! I I 7.5 - 7.9 I +3 1 I S.0 - 8.3 1 +6 1 I 8.4 - 3.7 I +9 1 l 8.8 - 9.1 1 +12 I I 9.2 - 9.6 I +15 1 I 9.7 - 10.2 I +18 1 I 10.3 - 10.8 I +21 I I 10.9 - 11.5 1 +24 I 1 11.6 - 12.3 1 +27 I 12.4 - I 13.2 I +30 I I 1 Table 3-17. Cas Furnace With Refriveration CcollnR Points Refvigeracfod Cas Furnace. 1 Cooling I SE Z I 171-177-i 83- s9- 95 I 1 761 821 881 941 up I I 1 8.0 - 8.3 1 01 +21 +41 +61 +8 1 I 8.4 - 8.7 1 +21 +11 +61 +91+10 I I 9.3 - 9.2 I a41 +61 +61+101+12 1 9.3 - 9.7 I +61 +81+101-121+14 1 I 9.8 - 10.3 I +31+101+121+141+16 1 110.4 - 10.9 1+101+t2i+1;1+165+18 I 1 11.0 - 11.5 1+121+141+161+'195+20 1 I I I I I I 7/7/83 ZONE 11 TACLE'3-14 (ADAPTED) INTERJOR THERMAL MASS POINTS MASS _ DUELLING ARFA SQUARE FOOT ff AREA 1,000 I 1,500 I 2,000 2,500 f 3,000 3,500 t 4,000 I 4,500 5.000 I SA. FT. i A 8 C D A 8 C D A B C D� A B C D A 8 C 0 1 A B C D A 8 C 0 1 A 6 v G :, - B z-:-1 °-0 2 2 2 2 2 2 2 0 i 2 2 2 0 1 0 0 0 0 0 0 O 0 0 0 0 0 1 0 0 0 0 0 0 0 C i 0. a 0 0 1 100. 4 4 4 2 2 2 2 2 2 2 2 2 2 2 2 0 2 2 2 0 2 2 0 0 2 2 0 0 2 2 0 0. 0 0 0 0 1 iSO 6 6 6 4 4 4 4 2 2 *2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 0 2- Z 2 0l 2 2 2 0 1 200 8 8 6 4 6 6 4 2 4 4 4 2 4 4 2 2 2 2 2 2' 2 2 2 2 2 2 2 2I 2 2 2 2I 2 2 0 1 250 10 10 8 6 6 6 6 4 6 6 4 2 4 4 4 2 4 4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 300 12 12 10 6 8 8 6 4 6 6 6 4 6 6 4 2 4 4 4 2 4 4 2 2 2 2 2 2 1 2 2 2 7 2.2 2 2 350 14 14 12 8 10 IG 8 6 6 6 6 4 6 6 6 2 6 4 4 2 4 4 4 2 4 4 2 2 I 4 4 2 7) 2 2 7 2 400 14 14 12 8 10 10 8 6 B 8 6 4 6 6 4 4 6 - 6 4 2 4 4 4 2 4 4 4 2 I 4 4 2 2 I 3 4 2 2 $00 18 13 16 10 12 12 10 .6 10 10 8 6 R 8 6 4 6 6 6 4 6 6 6 2 6 6 4 4 < 4 2 4 4 4 I 603 22 20 18 12 14 14 12 8 12 12 10 6 10 10 8 6 8 8 6 4 8 G 6 4 6 6 6 4 I 6 6 4 2 f• 6 6 4 2 1 • 700 i 24 24 20 14 18 16 i4 10 14 14 12 B 10 10 10 5 10 10 8 6 8 8 6 4 8 S. 6 4 16 A 6 41 6 6 6 2 230 26 24 22 16 70 16 15 10 14 14 12 8 12 10 10 6 10 10 8 6 10 R B 4 I ^ 6 6 4 I 8 6 6 4� 6 6 6 4 1 900 28 28 74 16 22 20 18 12 16 16 14 10 14 14 12 8 12 12 10 6 10 10 3 6s 8 '8 4 8 8 5 4 i 8 8 6 c 1,000 30 70 25 18 P2 20 20 14 18 IB i6 10 it 14 12 8 12 17 10 6 12 10 10 6 I10 10 8 6 8 8 C 4i 8 G 4 i 1,100 32 37. 28 20 24 24 22 14 20 20 18 10 16 16 14 8 (14 14 12 8 12 12 10 6 10 1J 10 6 In 10 8 6 ?•3 e f ; 1,200 34 32 30 22 26 26 22 16 22 20 18 12 18 18 14 10 14 14 12 8 14 12 12 8 I'12 12 10 6 10 10 8 6i In 10 8 6 r 1.3CO 37 34 32 22 28 26 24 16 22 22 20 12 18 18 1G 10 15 14 14 6 14 12 12 6 12 12 10 6 12 10 10 ci 10 1,400 34 34 32 24 28 28 26 18 24 24 20 14 20 20 18 12 18 16 14 10 14 14 12 8 14 14 12 8 !12 12 1G 6. 10 10 10 S 1 1,500 136 34 34 24 30 30 26 18 24 24 22 14 I22 20 18 12 18 18 16 10 74 34 30 22 1G 16 14 8 14 14 12 E 17 1: 10 (,I 1> 12 1;. o i 2,G00 34 34 32 22 30 30 26 18 26 26 1 14 120 20 18 12 18 18 16 10 1C 16 is G! 14 14 12 S ; I I30 30 22 26 1 8 26 26 20 6 22 22 20 1 6 2 2,50'0 4 24 22. 14 22 22 i9 :2 20 20 18 !:•I 19 l� It '0 J.000 34 32 30 22 30 30 26 l8 28 26 24 16 I24 24 22 14 22 27 20 14� :: :3 ti 3,500 I 32 32 30 20 30 30 26 la 128 28 24 16 26 24 27 14 ' ' `1 24 '20 14 ' 4.000 32 32 30 20 130 30 16 18 ! :'9 28 24 if 26 2S 2: if 4,500 ( 32 32 28 20 1 30 30 26 It _ 5.003 �. 32 17 2i 23j IJ G Y6 I- ! A) 1. 3'i Concrete Slab: HC -B.93'. R-.29; Factor -7.3 2. 3 3/4' Thick Common Brick: IIC=7.125; R-.13; Factor -7.3 , B) 1. Sh' Concrete Slab: HC -14.106: P-.418; Fbctor-7.1 WOOd StOVe C ) 1. 8" solid Filled Block: HC -2'1.63: R-1.93; Factor -6.1 4133 poinfs(no back up) 2. 8- solid Filled Block With Both Sides Exposed To Conditioned Air. ca.sablanca fan + 1 point NOTE: Use all square footage directly exposed to conditioned air for Thermal';Mass Area: HC -10.164; R --96L; Factor -6.1 0) 1- Thick Concrete/Tile: HC-2.SS; R-.083; Factorr3.7 Table 3-19. Zonally Controlled Electric Resistance Space Heating Points ' I Points foo this neasurc will I Table 3-20, Solar Water Hcztin�> With Cas Barka Paints , I be completed after the CEC I I has approved an Alternative I Component Package for Resistance I I seat. 1 Table 3-18. Active Solar Spnee Heating with Cas Points Net Solar Fraction 1 (MSF), ; I I 0-6 1 0 l I 7 - 14 I +2 I 15 - 23 1 +4 1 I 24 - 30 I +6 1 I 31 - 39 1 +8 1 1 40 - 47 ( : +10 1 1 48 - 55 I +12 I I 56 - 63 1 +14 i 64 - 71 1 +18 . 1 I 72 up I +20 1 Y.ultifamil (per unitpoints) Points I I 1 I Cas Only I I 0 1 I I seat Pomp 1 I I Floor Area ( Solar with Electric I Net Solar Fraction (NSF), Z i per unit, i I menti la Part 2 1 I 0 I I I Electric Resistance t I I I On 1f -40 ) ft2. 0.9 10-19 20-29 30-39 40-49 50-59 60-69 70-79 , 600-799 0 +3 +7 +10 +14 +17 +21 +24 800-999 0 +3 +5 +8 +11 +14 +16 +19 1,000-1,499 0 4.2 +4 +6 +8 +10 +12 +14 1,500-1,999 0 +1 +3+4 +6 +7 +8 +10 2X09 -and u 0' +1 +2 +4 +5 +6 +7 1 +9 All others (per building pnints) 800-899 900-999 0 0 +5 +4 +lU +9 rl4 +13 +19 +17 +24 +it +29 +34 +26 +30 1,000.1,199 0 +4 •+7 +ll +15 +19 +22 +26 1,20r�1,499 0 +3 +6 +9 +12 +15 +18 +21 1,500-1.999 0 +2 +5 +7 +9 +12 +14 +16 2,1100-:,999 +2 +3- +5 +7 +8- +10 +11 I 3,01:•0 nr.d tic -0 0 +, +3 +S +5 +7 +S +10 1 I Table 3-21. Other Vater Heattnq Pta. T-- I I I System Type ) I Points I I 1 I Cas Only I I 0 1 I I seat Pomp 1 I I 1 0 I ( Solar with Electric I ( Resistance OAckup I i Heeclny the Require- I i I menti la Part 2 1 I 0 I I I Electric Resistance t I I I On 1f -40 ) s 7 RESIDENTIAL ENERGY PLAN CHECK/INSPECTION SUMMARY FORM Owner #45My4 rot/ Climate Zone // Permit No.. Z5&1- 95- Floor SFloor Area /39S SF- Compliance FCompliance path: Package ❑ A ❑ B ❑ C ffi�oint System ❑ Budget t Other MIN R -VALUE DESCRIPTION REQ'D INSTALLED ITEMS (1) INSULATION• all" Roof/Ceiling 30.Qb f8' Wall ❑ Slab Floor Perimeter Raised Floor (2) INFILTRATION• ❑ (A) A vapor barrier is required in climate zones, 1, 14 & 16. (B) All manufactured windows and sliding glass doors shall meet the 1972 ANSI Air Infiltration Standards and shall be certified and labeled. COY (C) All swinging doors and windows leading to unconditioned areas shall be fully weatherstripped. Tight - the above standard features plus: ❑ (D) Continuous infiltration barrier ❑ (E) Electrical outlet plate gasket ❑ (F) Air-to-air heat exchanger (3) GLAZING: (A) Location Area Glazing %Floor Area Single Double Triple Q' Total Bldg V3.Oo /9 -?-7✓ (� North 3�,Vo y, c,/ ✓ [� East //61-00 7Af Lff" South .S -o _ 1,76 All West 4'f oO .�• ��_ ,/ ❑ Skylights (B) Shading Shading Coefficient Description (� East , && - South (�G [� West ,(p� ❑ Skylights [r (C) South Overhang Length of projection 2� ft. Description ❑ (D) Moveable insulation: Area ft Description (E) Thermal mass ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area Ft. 'HC= R= MC= Location ❑ Type - Area Ft. HC= R= MC= Location ❑ Type - Area Ft.Z HC= R= MC= Location ❑ Type - Area Ft.2 HC= R= MC= Location ❑ Type - Area -Ft.Z HC= R= MC= Location 7/83 . 1 FORM .�-�,•, ❑ (4) MASONRY AND FACTORY -BUILT FIREPLACES shall -be equipped with tight fitting closeable metal or glass doors covering the entire opening of the firebox; a combusion air intake equipped with a readily accessible, openable, and tight fitting damper to draw air from the outside of the building; and a tight fitting flue damper with a readily accessible.control. *1(5) HEATING, VENTILATING; AIR CONDITIONING SYSTEM (A)Heating ❑ Central Gas Furnace % (brand and model number) SE Btu/hr (heating capacity) 9 Heat Pump. % S (brand and model number) ACOP Btu/hr (heating capacity at 47°F) ❑ Active Solar ;type (liquid or air) Collector brand and ft2 model number solar fraction collector area collector orientation collector tilt rated y -intercept rated slope 93-11, Other 1,4/aDD Bu1�1AJ4 $TO✓E . (describe) (B) Cooling Electric Air Conditioner (brand and model number) (seasonal EER) Btu/hr (cooling capacity at 95°F) Electric Heat Pump EER Btu/hr (cooling capacity at 95°F) ❑ Other (describe) ❑ (C) A TWO-STAGE THERMOSTAT, which controls the supplementary heat on its second stage, shall be required for heat pumps. (D) AN AUTOMATIC SETBACK shall be provided for all thermostats, except those controlling heat pumps. (E) AN INTERMITTENT IGNITION DEVICE shall be provided for all gas-fired fan type central furnaces, gas-fired fan type wall furnaces and gas cooking appliances. Q� (F) BACKDRAFT DAMPERS shall be provided for all fan systems exhausting air to the outside. (G) DUCT CONSTRUCTION & INSULATION. All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or mastic to prevent air loss and shall be insulated to conform to the provisions of Section 1005 of the UMC, 1976 Edition. 7/83 2 FORK 1 (6) DOMESTIC WATER SYSTEM (A) Gas Only Gallons (brand and model number) (tank size) ❑ Heat Pump w/Electric Backup (brand and model number) Gallons 2 (tank size) 13* Active Solar (collector brand and model number) (rated y -intercept) (rated slope) (solar fraction) ft (backup heater type, brand and model number) (collector area) (collector.orientation) (collector tilt) ❑ Location of Solar Panels ❑ Other (Describe) (� :(B) TANK INSULATION. Storage type water heaters and storage and backup tanks for solar systems shall be externally wrapped with R-12 insulation or greater. [d� (C) PIPE INSULATION. The five feet of pipe closest to the water heater and outside conditioned space shall be insulated with a minimum of R-3. Steam and steam conditioned space shall be insulated with a minimum,of R-3. Steam and steam condensation return piping and recirculating hot water piping outside the building envelope shall.be insulated in accordance with T20 -1408(d). (D) FLOW RESTRICTORS shall be provided for showerheads and faucets as outlined in the new appliance efficiency standards and shall be certified to the Energy Commission. (7) LIGHTING (A) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficacy of not less than 25 lumeas per watt (usually florescent). i *1 Submit documentation of sizing heating and cooling equipment by Manual J, .sizing charts (form #4) or other approved methods,.section 2-5352(g),.and fill out the following: Heating: Winter design tem*#a a 2¢ °, elevation ti 2 0 ', heating load 2 ,0 BTU elev tion factor A x heating load = maximum outlet capacity gas furnace 2g90o BTU 7 PiWA Cooling: Summer design temperature 9� °, c.00ling load /99400 BTU (USE ONLY AS A SIZING GUIDE, COOLING MAY BE.INADEQUATE) *2 Submit T.I.P.S.E. chart or other approved system (form #5) to document sizing of solar panels. to-St7 ONLY AS SIZING GUIDE, COOLING IJIAY BE INADEQUATE ® DESIGN COMPLIANCE STATEMENT: The above building design meets the requirements of Title 24, Part 2, Chapter 2-53 of the California Administration Code. 7/83 S NA URE Of BUILDING DESIGNER OR PLICANT 3